ESD Survey Checklist Activity - Nasa
ESD Survey Checklist Activity - Nasa
ESD Survey Checklist Activity - Nasa
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>ESD</strong> <strong>Survey</strong> <strong>Checklist</strong> <strong>Activity</strong> ___________________________<br />
Conditions: Temp F ______ Humidity ______ Tech ________ QA _________<br />
Bldg.________ Room _________ POC __________ Test Date ____________<br />
Setup PC Prostat Analysis Equipment (Set Time, Temp, and Humidity) <br />
EMI, 1KV, Static charge source, two conductors (demo HBM / MM) <br />
1. Layout of EDPA<br />
2. Comments / Observations / Best Practices<br />
D-WK108-8.doc 1
Human Model Graphs.<br />
D-WK108-8.doc 2
3. Facility Ground<br />
3.1 Green Wire Ground O Yes / O No<br />
3.2 Auxiliary Ground O Yes / O No<br />
3.3 Ground Loop O Yes / O No<br />
3.4 CFCI (Receptacle /<br />
Bench Mount)<br />
O Wall / O Bnch<br />
Circuit Condition H G N<br />
3.5 Correct Wiring O<br />
3.6 No Ground O<br />
3.7 Polarity Reversal T T O<br />
3.8 Open Hot Neutral O<br />
4. Power Quality<br />
Test Measured Requirement Code F<br />
EE<br />
Line Voltage 120 VAC (RMS H-N 108~132)<br />
4.1 V<br />
H/N VAC<br />
V<br />
G/N<br />
VAC<br />
V<br />
H/N<br />
VAC<br />
4.2 Freq HZ Frequency 60 HZ<br />
90 - - - - 100 - - - - 110 - - - - 120 - - - - 130 - - - - 140<br />
Neutral to Ground (RMS G-N5 % V L >108 ~Amp<br />
Vd<br />
100 105 * 110 115 120<br />
I III I II I II I II II I III I II * ** III I II I III I II I II I II II I III I II I II I II I<br />
Vd @15A % V L I III I II I II I II II I III I II * ** III I II I III I II I II I II II I III I II I II I II I @ 15A<br />
Vd @20A % V L I III I II I II I II II I III I II * ** III I II I III I II I II I II II I III I II I II I II I @ 20A<br />
Vd @12A % V L I III I II I II I II II I III I II * ** III I II I III I II I II I II II I III I II I II I II I @ 12A<br />
4.4 ASCC Available Short Circuit Current<br />
ASCC 1<br />
Amps<br />
ASCC 2<br />
Trips CFCI O Yes / O No<br />
4.5 Z Ω
6. Resistivity (Ohms per sq.)<br />
Item/Accessory Requirement Resistivity<br />
Wrist strap resistor Mandatory 1 meg +/- 20%<br />
Cuff, skin, cord through to common groundable point Continuous
7. Personal Grounding<br />
7.1 Wrist Straps<br />
How is resistance / performance assured?<br />
# of Wrist Straps Checked =<br />
7.2 Shoe/Heel Strap # of heal straps in use in EDPA =<br />
Are mobile personnel using two Foot Grounders in conjunction with wrist straps ?<br />
# of heal straps checked =<br />
O ohm meter<br />
O continuous<br />
monitor<br />
Pass _____<br />
Fail ______<br />
O Yes / O No<br />
Pass_____<br />
Fail ______<br />
8. EDPA <br />
8.1 Are boundaries of the <strong>ESD</strong> controlled area clearly identified for the benefit of<br />
visitors, non technical, logistics or other untrained personnel entering the area?<br />
8.2 Are all <strong>ESD</strong>S items clearly identified and handled only at an <strong>ESD</strong> equipped<br />
workstation?<br />
8.3 What is the POC strategy for communication and protection of parts within the<br />
controlled area?<br />
O Yes / O No<br />
O Yes / O No<br />
9. Storage, Handling and Transportation<br />
9.1 Are static dissipative bags available for the transport of <strong>ESD</strong>S parts into and out of<br />
the EDPA<br />
9.2 Are totes or other protective packaging materials present for the transport of <strong>ESD</strong>S<br />
parts into and out of the EDPA?<br />
O Yes / O No<br />
O Yes / O No<br />
10. Cleaners / Solvents<br />
10.1 Is a proper <strong>ESD</strong> mat cleaner being used at regular intervals to prevent<br />
O Yes / O No<br />
contamination build up from body oils, flux residue, dust particles, and machine oils<br />
and greases?<br />
10.2 Are static generating aerosols in use at the workstation? O Yes / O No<br />
10.3 Is the static dissipative mat clear of non-essential insulators such as coffee cups, O Yes / O No<br />
food wrappers, regular bags, Styrofoam, plastic packaging and bottles and personal<br />
items by at least 1 inch?<br />
11. Work Floor Area<br />
11.1 Is there a path to common point ground (floor mat) for technicians who are too O Yes / O No<br />
mobile to wear a wrist strap?<br />
11.2 Are there any equipment generating charge fields within 1 meter of the<br />
O Yes / O No<br />
workbench<br />
11.3 Items found harboring charge fields within 1 meter of the workbench O Yes / O No<br />
12. Ionizer Test<br />
Ionizer Decay Test / file name _______________________________<br />
D-WK108-8.doc 5
13. CDM, MM, FIM Items and Activities Measured<br />
Item Type Model<br />
13.1<br />
13.2<br />
Serial<br />
Number<br />
Contactor<br />
to Gnd<br />