ENGINEERING SOLUTIONS<br />

FOR TILING, FLOORING & WATERPROOFING<br />

ARDEX Specification<br />

For tiling on the <strong>Dincel</strong> <strong>Construction</strong> <strong>System</strong> with Ardex tile adhesives<br />

1.1 SCOPE<br />

This specification covers tiling on the <strong>Dincel</strong> <strong>Construction</strong> <strong>System</strong> with Ardex tile adhesives, internally in<br />

areas such as bathrooms. (Note: when tiling in the shower recess area, please follow the Ardex<br />

specification for “waterproofing on the <strong>Dincel</strong> construction system with the WPM002”.)<br />

1.2 PRODUCT APPLICATION<br />

All products are to be used in strict accordance with the manufacturer’s recommendations.<br />

1.3 SURFACE PREPARATION<br />

The <strong>Dincel</strong> wall must be dry, firm & free of dust, dirt, oil, grease, & other contaminant materials, as well<br />

as being strong enough to support the weight of the tiles being fixed. Oily, greasy residues may be<br />

removed by detergent washing and rinsing with water.<br />

Ensure surfaces are dry before tiling, with no residual or permanent dampness.<br />

If using the ARDEX WA100 adhesive, mechanically roughen (e.g. sand with 80 grit sandpaper) the<br />

areas that are to receive the ARDEX WA100 adhesive spots.<br />

1.4 PRIMING<br />

ARDEX WA100 can be used without priming the surface using a notched trowel or spot fixing technique.<br />

If using ARDEX Optima or STS8 + E90, priming is necessary with Ardex 82 Ultraprime. Please note this<br />

primer is recommended for internal dry applications only.<br />

Mix Parts A+B thoroughly at the mixing ratio 1:1 by weight or by volume. This mix can be applied<br />

immediately, and is workable for about 60 minutes at temperatures of 20 degrees Celsius.<br />

Apply a thin coat of Ardex P82 primer using a short nap or sponge roller, leaving a thin coat of primer,<br />

no thicker than a thin coat of paint.<br />

DO NOT leave any bare spots and brush out excess primer to achieve a thin coat.<br />

Allow drying to a clear thin film before tile adhesives are applied.<br />

1.5 APPLICATION OF THE TILE ADHESIVES<br />

WA100: It is essential to use the correct mixing ratio of 1:1 Part A : Part B by weight or volume.<br />

Before fixing, ensure the substrate has been prepared and the tile or stone is free of dirt or dust.<br />

Ardex Australia Pty Ltd ABN 82 000 550 005<br />

Unit 7/20 Powers Road (P.O. Box 796), Seven Hills NSW 2147<br />

Telephone 02 9851 9100 Facsimile 02 9838 7970 www.ardexaustralia.com


Remove dust with a stiff brush and remove any loose particles or dust from the back of the stone or tile.<br />

The Ardex WA100 can be applied using a notched trowel, and although this adhesive is relatively stiff,<br />

spreading with the trowel will achieve greater contact to both the tile and the substrate.<br />

Apply spots of WA100 on the back of the stone or tile using a minimum of 5 spots applied evenly across<br />

the back, one in each corner and one in the centre. Ensure at least 10% coverage is achieved with the<br />

5 spots. The final spot thickness should be a minimum of 3mm and a maximum of 25mm. Any surplus<br />

adhesive should be removed from the surface of the tile and joints, before the adhesive sets.<br />

Optima: The mixing ratio of ARDEX Optima is 1 part liquid to 3 parts powder. Stir the ARDEX Optima<br />

liquid thoroughly and pour the accurate measure into a suitable clean plastic container. Add ARDEX<br />

Optima powder to the liquid whilst stirring with a mechanical paddle type mixer. Allow mixture to stand<br />

for 2 minutes and re stir before use.<br />

Before fixing ensure the substrate has been prepared & primed and the tiles are free from dust.<br />

The substrate surface and size of the tiles will determine the selection of the trowel. As a general guide<br />

use a 6x6x6mm notched trowel for walls. ARDEX Optima can be applied at a bed thickness greater<br />

than 1mm or less than 8mm.<br />

The tiles must be pressed firmly into the freshly combed mortar bed to ensure good contact with the<br />

mortar. Slide the tile at right angles to notch pattern to ensure 100% coverage on the back of the tile.<br />

<strong>Tile</strong>s with ribbed or keyed back profiles should also be buttered to ensure complete coverage. Lift a tile<br />

from time to time to ensure that there are no voids beneath the tile. Any surplus adhesive should be<br />

removed from the surface of the tile and joints, before the adhesive sets.<br />

STS8 + E90: For 20kg of powder, mix 3.6L of E90 with up to 5L of water and add to the powder.<br />

Before fixing ensure the substrate has been prepared & primed and the tile or stone is free of dirt or<br />

dust.<br />

The substrate surface and size of the tiles will determine the selection of the trowel. As a general guide<br />

use a 6x6x6mm notched trowel for walls.<br />

The tiles must be pressed firmly into the freshly combed mortar bed to ensure good contact with the<br />

mortar. Slide the tile at right angles to notch pattern to ensure 100% coverage on the back of the tile.<br />

<strong>Tile</strong>s with ribbed or keyed back profiles should also be buttered to ensure that the voids are filled.<br />

Ardex Australia Pty Ltd ABN 82 000 550 005<br />

Unit 7/20 Powers Road (P.O. Box 796), Seven Hills NSW 2147<br />

Telephone 02 9851 9100 Facsimile 02 9838 7970 www.ardexaustralia.com


12 PARKVIEW DRIVE, ARCHERFIELD, QLD 4108<br />

TEL: (07) 3276 5000 (Int; +61 7 3276 5000)<br />

FAX: (07) 3276 5076 (Int; +61 7 3276 5076)<br />

ABN 34 059 838 765<br />

14-8-2012<br />

<strong>Dincel</strong> <strong>Construction</strong> <strong>System</strong> Pty Ltd<br />

Level 3, 7K Parkes Street<br />

Parramatta NSW 2150 Australia<br />

Attention:- Mr Ross Drinkwater<br />

Re:- Compatibility of Mapei’s Keralastic T two part polyurethane adhesive system to <strong>Dincel</strong> <strong>Construction</strong><br />

<strong>System</strong>.<br />

We confirm that the above mentioned adhesive system has passed C1 & C2 wet & dry requirements of AS-<br />

4992-2007 when used in compliance with respective manufactures data sheets and in accordance to<br />

relevant Australian Standards for ceramic tiling.<br />

Should you be requiring any further assistance to this matter please do not hesitate to contact our<br />

Mr Joe Ceravolo on mobile 0418-159983 or this office.<br />

Regards<br />

Robert Tessarolo<br />

Technical Services<br />

Mapei Australia Pty Ltd<br />

Cc Mr Joe Ceravolo