Main Menu<br />
ENERGY EFFICIENCY<br />
Spec J1.5 – 2.<br />
Deemed-to-Satisfy Provisions<br />
Figure 2 TYPICAL R-VALUES FOR WALL CONSTRUCTION— continued<br />
(c)<br />
(d)<br />
External wall construction description Item Item description R-Value<br />
Denseweight hollow concrete block with<br />
internal plaster on battens or furring channels<br />
125 mm solid reinforced concrete (dense<br />
weight) – 10 mm internal plaster on battens or<br />
furring channels<br />
1. Outdoor air film (7 m/s) 0.03<br />
2. Denseweight hollow<br />
concrete block (See notes<br />
3 and 4)<br />
3. Airspace (20 mm to<br />
40 mm non-reflective and<br />
unventilated)<br />
4. Plasterboard, gypsum<br />
(10 mm, 880 kg/m 3 )<br />
0.15<br />
0.17<br />
0.06<br />
5. Indoor air film (still air) 0.12<br />
Total R-Value 0.53<br />
1. Outdoor air film (7 m/s) 0.03<br />
2. 125 mm minimum solid<br />
reinforced concrete (See<br />
note 3)<br />
3. Airspace (20 mm to<br />
40 mm non-reflective and<br />
unventilated)<br />
4. Plasterboard, gypsum<br />
(10 mm, 880 kg/m 3 )<br />
0.09<br />
0.17<br />
0.06<br />
5. Indoor air film (still air) 0.12<br />
Total R-Value 0.47<br />
(e)<br />
Timber wall – external 6 mm cement sheet<br />
cladding, 90 mm stud frame, 10 mm plaster<br />
1. Outdoor air film (7 m/s) 0.03<br />
2. Fibre cement (6 mm,<br />
1360 kg/m 3 )<br />
3. Airspace (90 mm<br />
nonreflective and<br />
unventilated)<br />
4. Plasterboard, gypsum<br />
(10 mm, 880 kg/m 3 )<br />
0.03<br />
0.17<br />
0.06<br />
5. Indoor air film (still air) 0.12<br />
Total R-Value 0.41<br />
BCA 2009 Volume One <strong>Australian</strong> <strong>Building</strong> <strong>Codes</strong> <strong>Board</strong> Page 436