06.10.2014 Views

Power Manager Brochure download - TSL

Power Manager Brochure download - TSL

Power Manager Brochure download - TSL

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MDU12-PM<br />

TOTAL LOAD MUST NOT EXCEED 16A<br />

0<br />

ALL FUSES 5A HRC<br />

1<br />

<strong>Power</strong> 1<br />

2 3 4 5 6 7 8 9 10 11 12<br />

MDU12-PM<br />

TOTAL LOAD MUST NOT EXCEED 16A<br />

0<br />

ALL FUSES 5A HRC<br />

1<br />

<strong>Power</strong> 1<br />

2 3 4 5 6 7 8 9 10 11 12<br />

Intelligent Mains Distribution<br />

Intelligent Mains Distribution<br />

The NEW <strong>Power</strong> <strong>Manager</strong> MDU Series from <strong>TSL</strong><br />

12-way intelligent power distribution with<br />

e-mail alert alarms and latching relays -<br />

MDU12-PM<br />

• Remote Ethernet control of the 12 separate outputs via<br />

secure Web browser<br />

• Sequential, immediate or user-configured delayed<br />

output startup<br />

• 16 x opto-isolated GPI alarm inputs<br />

• Ethernet SNMP alarms and E-mail alerts for all 16 x GPIs<br />

and 12 x fuses.<br />

• Ethernet Input power failure alarm<br />

• Programmable internal temperature sensor with SNMP<br />

alarm<br />

• Unit and SNMP configuration via secure Web browser<br />

interface<br />

• RS232 setup port via front and rear-mounted<br />

connectors (RJ11 and D9)<br />

• LAN status LED<br />

• Tri-colour output status LEDs<br />

• Rounded cable tie bar<br />

• Programmable internal temperature sensor with<br />

SNMP alarm<br />

• Unit and SNMP configuration via secure Web<br />

browser interface<br />

• LAN status LED<br />

• Rounded cable tie bar<br />

The all new 14-way dual Change-over unit<br />

MDU14-CO<br />

• 14 way fused IEC Outlets<br />

• Dual input auto change-over facility<br />

• Remote RS232 and GPO on rear D9 connector<br />

• 16 Amp double pole switch breaker<br />

• Tri-colour LED input and power indicators<br />

• Rounded cable tie bar<br />

The all new 14-way entry level Mains<br />

Distribution Unit - MDU14-B<br />

MDU14-CO<br />

13 14<br />

12-way intelligent power distribution with<br />

e-mail alert alarms - MDU12-PA<br />

MDU14-B<br />

• Ethernet SNMP alarms and E-mail alerts for all 16 x GPIs<br />

and 12 x fuses<br />

• Ethernet Input power failure alarm<br />

• 16 x opto-isolated GPI inputs<br />

13 14<br />

• 14 way fused IEC outlets<br />

• 16 amp double pole switch breaker<br />

• Rounded cable tie bar<br />

• Green LED power indicators<br />

• Competitive price point<br />

Take complete control of your<br />

Broadcast Infrastructure with <strong>TSL</strong>’s<br />

NEW <strong>Power</strong> Management Series<br />

For further information about <strong>TSL</strong>’s Professional Broadcast Products range or details of<br />

where to buy, please telephone +44 (0) 1628 676 200 or visit our web site www.tsl.co.uk<br />

12 Way <strong>Power</strong> <strong>Manager</strong> unit Intelligent remote power monitoring and control with<br />

e-mail alerts and latching relays.<br />

12 Way <strong>Power</strong> Alert unit Intelligent power distribution with e-mail alerts and<br />

intuitive browser-based management.<br />

<strong>TSL</strong><br />

Vanwall Road<br />

Maidenhead<br />

Berkshire SL6 4UB<br />

United Kingdom<br />

T: +44 (0) 1628 676 200<br />

F: +44 (0) 1628 676 299<br />

E: sales@tsl.co.uk<br />

www.tsl.co.uk<br />

14 Way Change-over unit Change-over switching between power sources in the<br />

event of mains failure, ensuring 100% uptime.<br />

14 Way Basic unit <strong>Power</strong> distribution with superior packing density and<br />

effective cable management at excellent value.


NEW <strong>TSL</strong> <strong>Power</strong> Management Series<br />

www.tsl.co.uk<br />

<strong>Power</strong>ful flexible solutions<br />

that satisfy all your power<br />

management requirements<br />

MDU -12-PM<br />

<strong>Power</strong> <strong>Manager</strong><br />

16xGPI monitors<br />

• Output Fail<br />

• Fuse Fail<br />

• Fan Fail<br />

• PSU Fail<br />

• Over Temp<br />

• Sig Presence<br />

New York<br />

Master Control<br />

London<br />

The <strong>Power</strong> Management range of mains distribution units<br />

from <strong>TSL</strong> have been designed to offer the full flexibility<br />

required by technical operators in leading broadcast<br />

applications. From the entry level MDU-14-B which<br />

provides 14 fused IEC outlets at superior density to the<br />

MDU-12PM <strong>Power</strong> <strong>Manager</strong> unit which offers full SNMP<br />

alarm monitoring plus a host of other features including<br />

sixteen GPI inputs for the remote management of nonnetworked<br />

rack hardware.<br />

Sao Paulo<br />

Racks Room<br />

WAN<br />

Satellite Uplink<br />

Ethernet<br />

monitoring from<br />

remote location<br />

E-mail/SMS<br />

Alerts<br />

LAN<br />

SNMP Alarm Centre<br />

Playout Centre<br />

Ethernet<br />

control from<br />

remote location<br />

• <strong>Power</strong> off<br />

• <strong>Power</strong> on<br />

• Sequential<br />

power up<br />

• Check Fuse<br />

Tokyo<br />

The <strong>Power</strong> <strong>Manager</strong> provides complete<br />

remote management and control over IP<br />

The MDU12-PM provides the systems administrator with the ability to monitor<br />

remotely over Local or Wide Area Networks the status of all broadcast<br />

equipment housed within a rack, using <strong>TSL</strong>’s state of the art Web browsing and<br />

power management technology, no matter how geographically remote the<br />

hardware is.<br />

The MDU-12-PM features a secure Web browser interface which provides access<br />

to the MDU setup pages for input, output, system and SNMP alarm monitoring,<br />

offering the systems administrator extended management and control of their<br />

broadcast infrastructure.<br />

KEY FEATURES<br />

• Secure Ethernet LAN/WAN<br />

connectivity and hardware<br />

management<br />

• 16 Opto-isolated External GPIs<br />

for non Ethernet equipment<br />

management<br />

• Remote control and monitoring<br />

of power input, & output states<br />

Secure Ethernet LAN/WAN<br />

connectivity and hardware<br />

management<br />

The <strong>Power</strong> <strong>Manager</strong> MDU offers the<br />

administrator with a secure Ethernet<br />

connection to the password protected<br />

web-based setup interface. The<br />

familiar Windows ® style system allows<br />

for configuration of input/output<br />

locations, SNMP alarms and the<br />

General Purpose Interface (GPIs)<br />

which provides the platform for the<br />

intelligent remote monitoring and<br />

control of rack hardware.<br />

Industry standard SNMP<br />

management<br />

The <strong>Power</strong> <strong>Manager</strong> MDUs use the<br />

widely recognised SNMP protocol to<br />

aid with their alarm and network<br />

power management. The use of SNMP<br />

alarm monitoring ensures that any<br />

networked hardware can be remotely<br />

managed from the remote racks room<br />

to the satellite uplink facility.<br />

SPECIFICATION<br />

• 12 way fused IEC outlets<br />

• Ethernet SNMP status and alarm<br />

monitoring<br />

• Internal temperature sensor<br />

with SNMP alarm<br />

• Energy saving latching relays<br />

• Secure web browser setup<br />

interface<br />

• Relay controlled outputs<br />

• Sequential, immediate or<br />

user-configured delayed startup<br />

• 16 x Opto-isolated GPI inputs<br />

with SNMP alarms<br />

• Email alerts for all alarm<br />

conditions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!