Technical Services: <strong>Tel</strong>: (<strong>800</strong>) <strong>381</strong>-<strong>9312</strong> / <strong>Fax</strong>: (<strong>800</strong>) 791-5500<br />

Sprinkler Cabinets<br />

3, 6, & 12 Sprinklers, 1/2 or 3/4 Inch NPT<br />

6 ESFR Sprinklers, 3/4 or 1 Inch NPT<br />

General<br />

Description<br />

<strong>Tyco</strong> ® Sprinkler Cabinets are constructed<br />

of metal enclosures with<br />

hinged covers designed to provide onsite<br />

storage of an emergency supply<br />

of sprinklers and a sprinkler wrench.<br />

NFPA 13 requires a representative<br />

number of each type of sprinkler used<br />

in a sprinkler system to be stored in a<br />

cabinet on-site to allow for immediate<br />

removal and replacement of sprinklers<br />

that may have operated or become<br />

damaged.<br />

Sprinkler Cabinets are manufactured<br />

of heavy gauge steel with knock-outs<br />

to accommodate NPT threaded sprinklers<br />

and are painted an attractive red<br />

enamel.<br />

WARNINGS<br />

The Sprinkler Cabinets described herein<br />

must be installed and maintained in<br />

compliance with this document, as<br />

well as with the applicable standards<br />

of the National <strong>Fire</strong> Protection Association,<br />

in addition to the standards of<br />

any other authorities having jurisdiction.<br />

Failure to do so may impair the<br />

performance of these devices.<br />

The owner is responsible for maintaining<br />

their fire protection system and devices<br />

in proper operating condition.<br />

The installing contractor or sprinkler<br />

manufacturer should be contacted<br />

with any questions.<br />

Technical<br />

Data<br />

Material<br />

Carbon Steel<br />

Weights<br />

3 Sprinkler Cabinet . . . . . . . . . . . . .<br />

. . . . . . . . . . . . . . . . .1.5 Lbs. (0,68 kg)<br />

6 Sprinkler Cabinet . . . . . . . . . . . . . .<br />

. . . . . . . . . . . . . . . . . 2.3 Lbs. (1,04 kg)<br />

12 Sprinkler Cabinet . . . . . . . . . . . . .<br />

. . . . . . . . . . . . . . . . . 4.0 Lbs. (1,81 kg)<br />

6 ESFR Sprinkler Cabinet . . . . . . . . .<br />

. . . . . . . . . . . . . . . . . 3.3 Lbs. (1,36 kg)<br />

Page of 4 AUGUST, 2007 TFP785


Page of 4<br />

TFP785<br />

REMOVE KNOCKOUTS<br />

TO ACCOMMODATE<br />

3/4" NPT SPRINKLERS<br />

HOLES ACCOMMODATE<br />

1/2" NPT SPRINKLERS<br />

HINGES<br />

7-1/4" 1-1/4"<br />

(184,2 mm) (31,8 mm)<br />

1-5/16"<br />

(33,3 mm)<br />

5-1/4" R<br />

(133,4 mm)<br />

DOOR SWING<br />

3-1/4" 2" 2-5/8" 1-3/16"<br />

(98,4 mm) (50,8 mm)<br />

(66,7 mm) (30,2 mm)<br />

HOLES FOR<br />

3/16" (5 mm)<br />

SCREWS<br />

1-3/4"<br />

(44,5 mm)<br />

5"<br />

(127,0 mm)<br />

1-1/8"<br />

(28,6 mm)<br />

1"<br />

(25,4 mm)<br />

5"<br />

(127,0 mm)<br />

6" (150 mm)<br />

MINIMUM<br />

CLEARANCE<br />

2-9/16"<br />

(65,1 mm)<br />

SPRINKLER<br />

SHELF<br />

SLOTS FOR<br />

1" (25,4 mm)<br />

STRAP HANGER<br />

WRENCH<br />

SHELF<br />

DOOR<br />

AND HINGES<br />

NOT SHOWN<br />

Figure 1<br />

3 Sprinkler Cabinet<br />

REMOVE KNOCKOUTS<br />

TO ACCOMMODATE<br />

3/4" NPT SPRINKLERS<br />

HOLES ACCOMMODATE<br />

1/2" NPT SPRINKLERS<br />

HINGES<br />

14-1/16"<br />

(357,2 mm)<br />

1-1/4"<br />

(31,8 mm)<br />

1-5/16"<br />

(33,3 mm)<br />

5-1/4" R<br />

(133,4 mm)<br />

DOOR SWING<br />

3-1/4"<br />

(98,4 mm)<br />

2"<br />

(50,8 mm)<br />

10-13/16"<br />

(274,6 mm)<br />

6"<br />

(152,4 mm)<br />

1-5/8"<br />

(41,3 mm)<br />

1-3/16"<br />

(30,2 mm)<br />

6" (150 mm)<br />

MINIMUM<br />

CLEARANCE<br />

2-9/16"<br />

(65,1 mm)<br />

1-3/4"<br />

(44,5 mm)<br />

1"<br />

(25,4 mm)<br />

5"<br />

(127,0 mm)<br />

HOLES FOR<br />

3/16" (5 mm)<br />

SCREWS<br />

SPRINKLER<br />

SHELF<br />

SLOTS FOR<br />

1" (25,4 mm)<br />

STRAP HANGER<br />

WRENCH<br />

SHELF<br />

DOOR<br />

AND HINGES<br />

NOT SHOWN<br />

Figure 2<br />

6 Sprinkler Cabinet


TFP785 Page of 4<br />

REMOVE KNOCKOUTS<br />

TO ACCOMMODATE<br />

3/4" NPT SPRINKLERS<br />

HOLES ACCOMMODATE<br />

1/2" NPT SPRINKLERS<br />

HINGES<br />

14-1/16"<br />

(357,2 mm)<br />

1-1/8"<br />

(28,6 mm)<br />

1-1/2"<br />

(38,1 mm)<br />

1-1/2"<br />

(38,1 mm)<br />

5-1/4" R<br />

(133,4 mm)<br />

DOOR SWING<br />

3-1/4"<br />

(98,4 mm)<br />

10-13/16"<br />

(274,6 mm)<br />

1-5/8"<br />

(41,3 mm)<br />

2" 6"<br />

1-3/16"<br />

(50,8 mm)<br />

(152,4 mm)<br />

(30,2 mm)<br />

6" (150 mm)<br />

MINIMUM<br />

CLEARANCE<br />

4-1/8"<br />

(104,8 mm)<br />

1-3/4"<br />

(44,5 mm)<br />

1"<br />

(25,4 mm)<br />

5"<br />

(127,0 mm)<br />

HOLES FOR<br />

3/16" (5 mm)<br />

SCREWS<br />

SPRINKLER<br />

SHELF<br />

SLOTS FOR<br />

1" (25,4 mm)<br />

STRAP HANGER<br />

WRENCH<br />

SHELF<br />

DOOR<br />

AND HINGES<br />

NOT SHOWN<br />

Figure 3<br />

12 Sprinkler Cabinet<br />

REMOVE KNOCKOUTS<br />

TO ACCOMMODATE<br />

1" NPT SPRINKLERS<br />

HOLES ACCOMMODATE<br />

3/4" NPT SPRINKLERS<br />

HINGES<br />

1-9/16"<br />

(39,7 mm)<br />

6-7/16" R<br />

(163,5 mm)<br />

DOOR SWING<br />

14-1/16"<br />

(357,2 mm)<br />

1-9/16"<br />

(39,7 mm)<br />

2"<br />

(50,8 mm)<br />

10-13/16"<br />

(274,6 mm)<br />

6"<br />

(152,4 mm)<br />

1-5/8"<br />

(41,3 mm)<br />

1-3/16"<br />

(30,2 mm)<br />

7" (180 mm)<br />

MINIMUM<br />

CLEARANCE<br />

3-1/8"<br />

(79,4 mm)<br />

3-13/16"<br />

(96,8 mm)<br />

2-3/8"<br />

(60,3 mm)<br />

1"<br />

(25,4 mm)<br />

6-3/16"<br />

(157,2 mm)<br />

HOLES FOR<br />

3/16" (5 mm)<br />

SCREWS<br />

SPRINKLER<br />

SHELF<br />

SLOTS FOR<br />

1" (25,4 mm)<br />

STRAP HANGER<br />

WRENCH<br />

SHELF<br />

DOOR<br />

AND HINGES<br />

NOT SHOWN<br />

Figure 4<br />

6 ESFR Sprinkler Cabinet


Page of 4<br />

TFP785<br />

Installation<br />

Sprinkler Cabinets are designed with<br />

two 3/16 Inch (4,7 mm) diameter holes<br />

for wall mounting or direct attachment<br />

to the system riser with a strap-type<br />

hanger. The Sprinkler Cabinet should<br />

be installed at or near the system control<br />

valve and must be stocked with an<br />

adequate supply of spare sprinklers<br />

and a sprinkler wrench.<br />

The stock of spare sprinklers should<br />

include sprinklers of each type and<br />

temperature rating as are installed in<br />

the sprinkler system, in the following<br />

quantities:<br />

Sprinklers In<br />

System<br />

Under 300 6<br />

300-1000 12<br />

Over 1000 24<br />

Spare Sprinklers<br />

Required<br />

The 3, 6, and 12 Sprinkler Cabinets<br />

are designed to accept both 1/2 & 3/4<br />

Inch NPT threaded sprinklers, whereas<br />

the 6 ESFR Sprinkler Cabinets are<br />

designed to accept both 3/4 & 1 Inch<br />

NPT threaded sprinklers. As necessary,<br />

insert a screwdriver blade from<br />

the front top of the shelf and under the<br />

near bottom part of the knockout annular<br />

ring. Press the screwdriver handle<br />

down to remove the knockout ring.<br />

Care and<br />

Maintenance<br />

The Sprinkler Cabinet, wrench, and<br />

stock of spare sprinklers should be inspected<br />

at least quarterly. The following<br />

items should be checked:<br />

• The Sprinkler Cabinet should be<br />

readily accessible, and not exposed<br />

to a corrosive atmosphere or temperatures<br />

in excess of 100°F (38°C).<br />

• The stock of spare sprinklers should<br />

include an adequate number of each<br />

type and temperature rating.<br />

• The stock of sprinklers must be in<br />

good condition.<br />

• A sprinkler wrench of the appropriate<br />

type must be included in the Sprinkler<br />

Cabinet.<br />

Limited<br />

Warranty<br />

<strong>Products</strong> manufactured by <strong>Tyco</strong> <strong>Fire</strong><br />

& Building <strong>Products</strong> (TFBP) are warranted<br />

solely to the original Buyer for<br />

ten (10) years against defects in material<br />

and workmanship when paid for<br />

and properly installed and maintained<br />

under normal use and service. This<br />

warranty will expire ten (10) years from<br />

date of shipment by TFBP. No warranty<br />

is given for products or components<br />

manufactured by companies not affiliated<br />

by ownership with TFBP or for<br />

products and components which have<br />

been subject to misuse, improper installation,<br />

corrosion, or which have not<br />

been installed, maintained, modified or<br />

repaired in accordance with applicable<br />

Standards of the National <strong>Fire</strong> Protection<br />

Association, and/or the standards<br />

of any other Authorities Having Jurisdiction.<br />

Materials found by TFBP to be<br />

defective shall be either repaired or replaced,<br />

at TFBP’s sole option. TFBP<br />

neither assumes, nor authorizes any<br />

person to assume for it, any other obligation<br />

in connection with the sale of<br />

products or parts of products. TFBP<br />

shall not be responsible for sprinkler<br />

system design errors or inaccurate or<br />

incomplete information supplied by<br />

Buyer or Buyer’s representatives.<br />

In no event shall TFBP be liable, in<br />

contract, tort, strict liability or under<br />

any other legal theory, for incidental,<br />

indirect, special or consequential damages,<br />

including but not limited to labor<br />

charges, regardless of whether TFBP<br />

was informed about the possibility of<br />

such damages, and in no event shall<br />

TFBP’s liability exceed an amount<br />

equal to the sales price.<br />

The foregoing warranty is made in lieu<br />

of any and all other warranties, express<br />

or implied, including warranties<br />

of merchantability and fitness for a<br />

particular purpose.<br />

This limited warranty sets forth the exclusive<br />

remedy for claims based on<br />

failure of or defect in products, materials<br />

or components, whether the claim<br />

is made in contract, tort, strict liability<br />

or any other legal theory.<br />

This warranty will apply to the full extent<br />

permitted by law. The invalidity,<br />

in whole or part, of any portion of this<br />

warranty will not affect the remainder.<br />

Ordering<br />

Procedure<br />

When placing an order, indicate the full<br />

product name. Contact your local distributor<br />

for availability.<br />

Sprinkler Cabinet:<br />

Specify: (Description), P/N (specify).<br />

3 Sprinkler Cabinet. . . . . . . . . . . . . . . . . P/N 1177<br />

6 Sprinkler Cabinet. . . . . . . . . . . . . . . . . P/N 1119<br />

12 Sprinkler Cabinet . . . . . . . . . . . . . . . . P/N 1124<br />

6 ESFR Sprinkler Cabinet . . . . . . . . . . . P/N 1111<br />

TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446