<strong>Bio</strong> Imaging Systems<br />

A top-quality bio <strong>imaging</strong> <strong>systems</strong> outstands<br />

with excellent sensitivity, lowest<br />

background noise and a sophisticated,<br />

yet intuitive software that along with<br />

just controlling the system also allows<br />

for image analysis and post-processing.<br />

PEQLAB's bio <strong>imaging</strong> <strong>systems</strong> meet<br />

with their technical innovations even the<br />

highest demands and set a new standard<br />

in the fields of fluorescence, chemiluminescence<br />

and bioluminescence <strong>imaging</strong>.<br />

HIGHEST SENSITIVITY<br />

Sensitivity is the key feature of a great<br />

<strong>imaging</strong> system, but depends on the<br />

harmonised interplay of multiple components<br />

like sensor, objective and darkroom.<br />

Especially the detection of faint<br />

fluorescence and chemiluminescence<br />

signals poses high challenges to sensitivity<br />

and <strong>imaging</strong> properties of an optical<br />

system. Only high tech monochromatic<br />

CCD sensors meet these demands, as<br />

they not only exhibit highest sensitivity,<br />

but also lowest background noise. All of<br />

PEQLAB's <strong>imaging</strong> <strong>systems</strong> are equipped<br />

only with specially manufactured 'scientific<br />

grade' CCD sensors and possess<br />

extremely light intense objectives. This<br />

highly coordinated top-quality hardware<br />

guarantees a maximum of image definition<br />

and fidelity. Additionally, with the<br />

usage of special lens <strong>systems</strong>, unwanted<br />

side effects like vignetting and image<br />

contortions are completely eliminated.<br />

LOWEST BACKGROUND<br />

Highest sensitivity can only be realised in<br />

combination with very low background<br />

noise, as otherwise faint signal would<br />

be overshadowed. Background noise<br />

is caused on the one hand thermically<br />

by infrared (IR) signals and on the other<br />

hand during the sensor readout by faintest<br />

leakage currents. PEQLAB‘s <strong>imaging</strong><br />

sys tems excel with lowest background<br />

noise due to their highly efficient double<br />

cooling system that constantly cools CCD<br />

sensor and camera chamber to reduce<br />

IR-noise. Continuing improvements in the<br />

field of cameras optics and optimisation<br />

of sensor readout complete the reduction<br />

of background noise.<br />

Moreover, PEQLAB‘s high quality darkrooms<br />

contribute to absolute background<br />

signal diminuition by totally eliminating<br />

interfering light and inner surface reflections.<br />

The darkrooms are fitted with<br />

special gaskets that guarantee pitch<br />

dark sealing, ban any light incidence<br />

and are internally lacquered with a<br />

special gap-free black anti-reflection<br />

coating. Another advantage of our <strong>systems</strong><br />

is the adjustable filter wheel and an extendable<br />

UV-table for preparative use.<br />

UV tables by PEQLAB impress with a<br />

very low heat build-up and a highly<br />

homogenous illumination. For most sensitive<br />

applications that demand a maximum<br />

contrast and minimal background<br />

'glow', the exclusive SUPER-BRIGHT<br />

UV tables are available. The innovative<br />

SUPER-BRIGHT technology minimises<br />

background 'glow' and displays exceptional<br />

homogeneity at the same time.<br />

This enables detection and quantification<br />

even of the faintest signals.<br />

INTUITIVE SOFTWARE<br />

Our purpose is to generate high quality<br />

image date that is a 1:1 reproduction of<br />

reality. Substantial scientific statements<br />

should only be based on unmodified<br />

raw-data. Possible modifications of<br />

any image raw data should always be<br />

under the user's control. Without exception<br />

our <strong>imaging</strong> <strong>systems</strong> and software<br />

were designed to fulfil the premise of<br />

highest data fidelity and integrity. The<br />

included licence-free software enables<br />

camera control, network compliance,<br />

image analysis and post-processing.<br />

Well arranged and intuitively to use,<br />

our software offers all functions that are<br />

needed to objectively and definitely<br />

evaluate the image data integrity and<br />

quality. Also for more sophisticated analyses<br />

like e.g. automatic lane detection,<br />

molecular weight and signal intensity<br />

calculations substantial software modules<br />

are already pre-installed.<br />

For even more complex analyses we<br />

also offer the <strong>Bio</strong>-1D software suite with<br />

many additional functions like e.g. densiometric<br />

quantifications and calculation<br />

of the apparent molecular weight. Of<br />

course we also offer network-licences<br />

(5-50) of the <strong>Bio</strong>-1D software for MS<br />

Windows Server.<br />

For the majority of our <strong>systems</strong> we do<br />

offer demonstrations in your laboratory<br />

- of course free of charge. Just ask!<br />

ORDERING INFORMATION • BIO IMAGING SYSTEMS<br />

Fon +49 9131 610 70 - 20 · Fax +49 9131 610 70 - 99 Freecall(D) 0800 100 2016 · Freefax(D) 0800 100 9016


FUSION FX7 Advance Chemiluminescence System<br />

Top class chemilumiscence/<br />

fluorescence combisystem:<br />

The allrounder with the technical<br />

specifications of a specialist<br />

Includes the sophisticated, yet<br />

intuitive analising and control<br />

software 'FUSION-CAPT'<br />

The Fusion FX7 Advance is a universal<br />

<strong>imaging</strong> system for chemiluminescence,<br />

bio luminescence, fluorescence and chemi<br />

fluorescence assays.<br />

With the Epi-UV module in the top of<br />

the darkroom it offers along with transillumina<br />

tion also the possibility of incident<br />

light fluorescence excitation. The Fusion<br />

FX7 Advance represents a sophisticated<br />

all-in-one solution for every common<br />

fluo res cence and chemiluminescence<br />

application.<br />

SPECIAL FEATURES<br />

- Highest sensitivity, great dynamic<br />

range and optimal resolution<br />

- Up-to-date supercooled CCD sensor<br />

(∆T= – 67°C)<br />

- Highly sensitive 4.2/10 megapixel<br />

CCD camera with 16 bit technology<br />

(65,536 grayscales)<br />

- PC-controlled, motorised fixed angle<br />

objective with autofocus<br />

- Innovative image acquisition modes<br />

for excellent results on the first run<br />

(even with unknown signal intensities)<br />

- Suitable for all commonly used<br />

chemiluminescence substrates<br />

- Powerful FUSION-CAPT control<br />

software suite for image analysis<br />

and post-processing<br />

HIGHEST IMAGE FIDELITY<br />

A hallmark feature of an outstanding<br />

chemiluminescence <strong>systems</strong> is the high<br />

quality of the optics and the CCD sensor.<br />

The Fusion FX7 Advance excells<br />

in image quality with its impressive<br />

4.2/10 megapixel 16 bit (65,536<br />

grayscales) CCD sensor. Due to the<br />

extremely high number of pixels the sensitivity<br />

can be increased up to 64 times<br />

by merging adjacent pixels ('binning').<br />

Thereby the Fusion FX7 Advance is<br />

the ideal system for every kind of chemiluminescence,<br />

bioluminescence or in<br />

vivo luminescence analysis and meets<br />

the highest demands for resolution and<br />

image quality.<br />

HIGHEST SENSITIVITY<br />

The Fusion FX7 Advance offers a<br />

fixed angle objective with extremely<br />

high lens speed (f: 0.84) and autofocus<br />

that guarantees crispiest images even<br />

at short distances (< 20 cm) without the<br />

need of an additional close-up lens.<br />

The short distance and the omission of<br />

the close-up lens avoid loss of signal<br />

intensity and allow for compact design.<br />

SUITABLE FOR THE FOLLOWING<br />

METHODS AND SUBSTRATES<br />

Chemiluminescence<br />

AceGlow, SuperSignal,<br />

ECL, ECL Plus, ECL–Advance,<br />

CSPD, CDP Star<br />

Fluorescence DNA/RNA <strong>imaging</strong><br />

Ethidiumbromide, Gel Star,<br />

SYBR Green, SYBR Gold<br />

Fluorescence and classical<br />

protein <strong>imaging</strong><br />

SYBRO Orange/Ruby/Red,<br />

Texas Red Fluorescein,<br />

Qdot, GFP, RFP, YFP,<br />

Coomassie Brilliant Blue, Silver Star<br />

Examples of experimental<br />

applications<br />

Analysis of Western blot membranes<br />

and thin layer chromatography sheets<br />

(fluorescence, 'shadowing'), in vivo<br />

fluorescence and luminescence (also<br />

in MTP-format)<br />

ORDERING INFORMATION • FUSION FX7 ADVANCE CHEMILUMINESCENCE SYSTEM<br />

PRODUCT DESCRIPTION CAT. NO.<br />

FUSION FX7 Advance Chemiluminescence/fluorescence <strong>imaging</strong> system 60-FU-26MA<br />

Chemiluminescence/fluorescence <strong>imaging</strong> system<br />

with Epi-UV and SUPER-BRIGHT technology<br />

60-FUUV-26MXA<br />

Fon +49 9131 610 70 - 20 · Fax +49 9131 610 70 - 99 Freecall(D) 0800 100 2016 · Freefax(D) 0800 100 9016


Chemiluminescence Systems Overview<br />

MODEL<br />

Application<br />

Fusion FX7<br />

Advance<br />

Fusion SL<br />

Advance<br />

Fusion Solo<br />

Chemiluminescence yes yes yes yes<br />

<strong>Bio</strong>luminescence yes yes yes yes<br />

Fluorescence yes optional no optional<br />

Chemifluorescence yes optional no optional<br />

Imaging properties<br />

Fusion Xpress<br />

'Scientific grade' CCD camera yes (USB) yes (USB) yes (USB) yes (FireWire)<br />

16 bit grayscale yes yes yes yes<br />

Sensor resolution 4.2 megapixel 4.2 megapixel 4.2 megapixel 2.0 megapixel<br />

Maximum resolution (interpolated) 10 megapixel 10 megapixel 10 megapixel 5.5 megapixel<br />

Dynamic range 4.8 decades 4.8 decades 4.8 decades 4.8 decades<br />

Camera cooling ∆T = – 67 °C ∆T = – 67 °C ∆T = – 67 °C ∆T = – 50 °C<br />

Image transmission rate (10 images/s) yes yes yes yes<br />

Background < 2 % < 2 % < 2 % < 4 %<br />

Objective<br />

Fixed angle (f:0.84)<br />

motorised<br />

Fixed angle (f:0.84)<br />

manual<br />

Fixed angle (f:0.84)<br />

manual<br />

Autofocus yes no no yes<br />

Zoom (f:1.2)<br />

motorised<br />

ORDERING INFORMATION • FUSION CHEMILUMINESCENCE SYSTEMS OVERVIEW<br />

Maximum viewing range 23 cm x 23 cm 23 cm x 23 cm 16 cm x 16 cm 20 cm x 26 cm<br />

Darkroom<br />

UV/blue transilluminator yes optional no optional<br />

Epi-UV/blue optional optional no optional<br />

SPECTRA-module (RGB/NIR) optional optional no optional<br />

Motorised filterwheel yes yes no yes<br />

Automatic tray position recognition yes no no yes<br />

Number of tray positions 5 5 4 2<br />

Automatic illumination yes no no yes<br />

Software<br />

PC-controlling yes yes yes yes<br />

Pre-configured image modes yes yes yes yes<br />

Quantification yes yes yes yes<br />

Absolute image data integrity yes yes yes yes<br />

'Binning' (2 x 2 to 8 x 8) optional optional optional optional<br />

Interpolation optional optional optional optional<br />

Data export to Excel yes yes yes yes<br />

Weights and measurements<br />

Weight 58 kg 48 kg 25 kg 48 kg<br />

Measuments in cm (H x W x D) 95 x 42 x 44 95 x 42 x 44 43 x 35 x 35 95 x 42 x 44<br />