25.10.2014 Views

CSN Industrie Srl UNI EN ISO 9001:2000 & UNI CEI ... - Dental2000.It

CSN Industrie Srl UNI EN ISO 9001:2000 & UNI CEI ... - Dental2000.It

CSN Industrie Srl UNI EN ISO 9001:2000 & UNI CEI ... - Dental2000.It

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>CSN</strong> <strong>Industrie</strong> S.r.l.<br />

COMPANY WITH QUALITY SYSTEM CERTIFIED BY<br />

<strong>UNI</strong> <strong>EN</strong> <strong>ISO</strong> <strong>9001</strong>:<strong>2000</strong> & <strong>UNI</strong> <strong>CEI</strong> <strong>EN</strong> <strong>ISO</strong> 13485<br />

www.csn-industrie.it


Reduced size<br />

Two sizes available:<br />

- Size 1 26.3 x 38.7 x 5.7 mm<br />

- Size 2 30,6 x 42.6 x 5.7 mm<br />

<br />

High resolution CCD<br />

CCD with 26.3 lp/mm resolution, 19 µm pixel size<br />

and Caesium Iodide Scintillator (CSI technology)<br />

that produces very high resolution images while<br />

reducing the X-ray dose received by the patient.<br />

It incorporates a fiber optic layer that protects<br />

the microprocessor and drives light from the<br />

scintillator directly to the CCD surface, with a<br />

real grey transfer of 16 bit (i.e. 4096 grey levels).<br />

CSI<br />

The Caesium Iodide Scintillator shelter is the first one<br />

to capture the X-rays and transform them into visible<br />

light.<br />

It is designed with a vertically grown process that<br />

generates a columnar microstructure to ensure<br />

excellent image quality.<br />

Fiber Optic: FOP<br />

Protective Film<br />

CCD<br />

It transforms light into digital images, with the high<br />

resolution of 26.3 lp/mm, which correstonds to<br />

1508x1200 pixel.<br />

You can be sure, no detail wiil be missed !<br />

Scintillator: CSI (Ti)<br />

2D Image Device: CCD


New design<br />

Studied to guarantee outstanding comfort to<br />

the patient and easy and accurate positioning<br />

even in the narrowest oral cavities.<br />

<br />

Instant image acquisition<br />

The integrated chip with USB 2.0 standard<br />

provides real time image acquisition (3 seconds).<br />

Power is supplied directly through the computer<br />

USB port.<br />

<br />

<strong>CSN</strong> Ready Technology<br />

This function eliminates the need to manually<br />

activate the sensor for image acquisition.


New cable/sensor connection<br />

The inclination of 30° guarantees easy and<br />

accurate use of the sensor with the maximum<br />

patient comfort.<br />

<br />

Sensor holders for Parallel technique<br />

RX2 HP sensor is equipped with the Sensor<br />

holder kit for parallel technique. It ensures<br />

perfect image acquisition in vertical and<br />

horizontal position, bitewing and endo<br />

techniques.<br />

The sensor holder can be sterilized in autoclave<br />

and is essential for the dental practitioner to get<br />

images perfectly parallel to the x-ray unit cone.<br />

This is particularly necessary in endodontics,<br />

periodontal and implantological treatments.<br />

The sensor holders are made of a special resin<br />

that gives them an optimum flexibility, thus<br />

improving the easy use by the practitioner with<br />

the greatest patient comfort.<br />

Bitewing<br />

Endo<br />

Perioapical<br />

HOLDER SPARE PARTS<br />

Posteriors<br />

Perioapical<br />

Endo<br />

Bitewing<br />

Rings<br />

Disp. sheets<br />

48WRX252<br />

48WRX253<br />

48WRX254<br />

48WRX255<br />

48WRX256<br />

48WRX2G500<br />

Posterior


<strong>CSN</strong> Image Software<br />

The Csn Image Software complies with all the<br />

Italian directives for the digital imaging in<br />

Dentistry.<br />

The software has a new, modern and innovative<br />

interface and integrates the possibility of<br />

acquiring images from all dental equipments<br />

(intra oral camera - Radiovedeography -<br />

Photocamera - Digital Panoramic - Tac and<br />

Panoramic in Dicom format).<br />

New Filters have been integrated in the<br />

software in order to improve image resolution<br />

and enhance the diagnosis:<br />

Structure enhancement (to increase image<br />

contrast and resolution), restorative dentistry<br />

effect (to increase the contrast between dentine<br />

and enamel) Periodontics effect (to enhance<br />

visualization of periodontic areas) Endodontics<br />

(to contrast automatically the tooth apex).<br />

Images can be added to the odontogram or a<br />

full dental status can be created. Moreover,<br />

images can be sent automatically via e-mail, or<br />

saved on a CD.<br />

The Measuring function, either linear and by<br />

segments, has been implemented, with the auto<br />

saving of all the measures (by re-opening the<br />

image, measures don't get lost). Moreover, a<br />

new function allows you to make drawings and<br />

add text to images.


RX2 HP Kit includes:<br />

1 sensor - size 1 or size 2<br />

1 USB Electronics for digitalizing images<br />

1 USB cable - 3 meters<br />

<br />

System requirements:<br />

100 hygienic disposable sheets<br />

1 sensor holder Kit for Parallel technique:<br />

2 vertical, 2 horizontal , 2 endo , 1 bitewing<br />

1 power supply for computer with USB port 1.0<br />

or for old processors<br />

1 CD with the <strong>CSN</strong> Image software<br />

1 Wall mount sensor holder<br />

CPU: Intel® Centrino Duo or superior<br />

RAM: 1024 Mb or higher<br />

USB: 1 free USB port 2.0 (Intel® o Via Tech®)<br />

Video card: 64 Mb or higher<br />

Monitor: 15'' to 17''<br />

minimal resolution 1024x768<br />

O.S.: Windows XP® (32 bit) Windows Vista® (32 bit)<br />

<br />

Technical Characteristics:<br />

Real resolution:<br />

Theoretical resolution:<br />

Grey levels:<br />

> 20 lp/mm<br />

26,3 lp/mm<br />

4096 (16 bit)<br />

Pixel size: 19 µm<br />

Technology:<br />

Interface:<br />

CCD + Fiber Optic + CSI Scintillator<br />

USB 2.0, compatible with old standard,<br />

with power supply<br />

Image transfer speed:<br />

1.61 sec. In high definition<br />

Image dimensions: Size 1: 1508 x 1200 pixel<br />

Size 2:<br />

1700 x 1200 pixel<br />

Sensor dimensions: Size 1: 26.3 x 38.7 x 5.7 mm<br />

Size 2:<br />

30.6 x 42.6 x 5.7 mm<br />

Active Surface: Size 1: 30 x 20 mm (600 mm 2 )<br />

Size 2: 34 x 24 mm (800 mm 2 )<br />

Intel® Centrino Duo is registered trademark of Intel Corp. - Windows XP® and Windows Vista® are registered trademarks of Microsoft Corp.<br />

COMPANY WITH QUALITY SYSTEM CERTIFIED BY <strong>UNI</strong> <strong>EN</strong> <strong>ISO</strong> <strong>9001</strong>:<strong>2000</strong> and <strong>UNI</strong> <strong>CEI</strong> <strong>EN</strong> <strong>ISO</strong> 13485<br />

<strong>CSN</strong> <strong>Industrie</strong> S.r.l.<br />

Via Aquileja, 43/B - 20092 Cinisello Balsamo Mi - Italy<br />

Ph +39 2 61.86.111 - Fax +39 2 61.29.06.76<br />

e-mail: export@csn-industrie.it - www.csn-industrie.it<br />

ZRX2HP/0408<strong>EN</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!