▶ The below table shows flue gas temperature and <strong>LNG</strong> usage depending on the furnace<br />

pressure. Those data are obtained through field testing.<br />

[Table: <strong>LNG</strong> usage <strong>of</strong> large rolling heating furnace depending on the furnace pressure changes ]<br />

Time<br />

Furnace<br />

Pressure<br />

Main <strong>LNG</strong><br />

Usage<br />

MAIN Exhaust gas<br />

from body<br />

Exhaust gas<br />

from regenerative burner<br />

2007.9.5 mmAq Nm3/h 온도(℃) O2(%) 온도(℃) O2(%)<br />

16:17 -0.6 1609 875.6 5 122.9 13.8<br />

16:18 -0.4 1758 870(880) 4.2 14.6<br />

16:21 -0.2 1965 828.2 7.4 145.7 13.9<br />

16:26 -0.24 1689 835 4.7 130.8 13.9<br />

16:47 0 1456 831 6 119.6 14.1<br />

16:58 0 1355 833.8 5.4 120.2 14.5<br />

17:16 0.33 1439 831.7 5.2 124.8 14<br />

17:27 0.24 1377 823.2 5.9 124.6 14<br />

17:39 0.3 1301 826.9 5.2 124.1 14<br />

18:00 0.3 1301 821.5 4.9 124.8 13.5<br />

Remark<br />

Main Exhaust<br />

Damper<br />

40% Open<br />

Main Exhaust<br />

Damper<br />

30% Open<br />

Main Exhaust<br />

Damper<br />

28.2% Open