Thermoelectric <strong>Air</strong> <strong>Conditioner</strong><br />
ACAC <strong>600</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong><br />
Heating & Cooling Unit for hazardous environment<br />
<strong>Ex</strong>plosion <strong>Proof</strong> Rating <strong>ATEX</strong> Zone 2 T5<br />
Dust and Water Protection Standard IP55<br />
INHECO part number: 8700001
delta T (°F)<br />
delta T (°C)<br />
<br />
<br />
No Controller & Power Supply provided by INHECO<br />
<br />
Performance curve for ACAC <strong>600</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong><br />
Cooling Data<br />
ACAC <strong>600</strong> <strong>Air</strong> <strong>BTU</strong> <strong>Conditioner</strong> <strong>Ex</strong> <strong>Proof</strong> Heater (<strong>600</strong> <strong>BTU</strong>/hr) ACAC-180W<br />
10 °C<br />
0 °C<br />
-10 °C<br />
-20 °C<br />
+25 °C ambient<br />
+60 °C ambient<br />
-30 °C<br />
-40 °C<br />
-50 °C<br />
0 W 50 W 100 W 150 W 200 W 250 W<br />
Capacity (W)<br />
ACAC <strong>Air</strong> <strong>600</strong> <strong>Conditioner</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong> Heater (<strong>600</strong> ACAC-<strong>600</strong><strong>BTU</strong>/HR<br />
<strong>BTU</strong>/hr)<br />
10 °F<br />
-10 °F<br />
-30 °F<br />
-50 °F<br />
+77 °F ambient<br />
+140 °F ambient<br />
-70 °F<br />
-90 °F<br />
0 <strong>BTU</strong>/HR 100<br />
<strong>BTU</strong>/HR<br />
200<br />
<strong>BTU</strong>/HR<br />
300<br />
<strong>BTU</strong>/HR<br />
400<br />
<strong>BTU</strong>/HR<br />
500<br />
<strong>BTU</strong>/HR<br />
<strong>600</strong><br />
<strong>BTU</strong>/HR<br />
700<br />
<strong>BTU</strong>/HR<br />
800<br />
<strong>BTU</strong>/HR<br />
Capacity (<strong>BTU</strong>/HR)
delta T (°C)<br />
delta T (°F)<br />
Heating Data<br />
ACAC <strong>Air</strong> <strong>600</strong> <strong>Conditioner</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong> Heater (<strong>600</strong> ACAC-180W<br />
<strong>BTU</strong>/hr)<br />
10 °C<br />
0 °C<br />
-10 °C<br />
-20 °C<br />
+25 °C ambient<br />
+60 °C ambient<br />
-30 °C<br />
-40 °C<br />
-50 °C<br />
320 W 370 W 420 W 470 W 520 W<br />
Capacity (W)<br />
<strong>Air</strong> ACAC <strong>Conditioner</strong> <strong>600</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong> Heater (<strong>600</strong> ACAC-<strong>600</strong><strong>BTU</strong>/HR<br />
<strong>BTU</strong>/hr))<br />
10 °F<br />
-10 °F<br />
+77 °F ambient<br />
-30 °F<br />
+140 °F ambient<br />
-50 °F<br />
-70 °F<br />
-90 °F<br />
1100<br />
<strong>BTU</strong>/HR<br />
1200<br />
<strong>BTU</strong>/HR<br />
1300<br />
<strong>BTU</strong>/HR<br />
1400<br />
<strong>BTU</strong>/HR<br />
1500<br />
<strong>BTU</strong>/HR<br />
1<strong>600</strong><br />
<strong>BTU</strong>/HR<br />
1700<br />
<strong>BTU</strong>/HR<br />
1800<br />
<strong>BTU</strong>/HR<br />
1900<br />
<strong>BTU</strong>/HR<br />
Capacity (<strong>BTU</strong>/HR)
Dimensions ACAC <strong>600</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong><br />
Dimensions in mm [inch]<br />
256 [10,08]<br />
122,4 [4,82]<br />
Mounting screw<br />
thread (blind hole)<br />
Sensor Cabinet<br />
Heat Sink<br />
137 [5,40]<br />
178 [7,01]<br />
Cabinet<br />
Fan<br />
Conductor<br />
Bushing<br />
Threaded<br />
Cabinet<br />
Heat Sink<br />
Insulation<br />
Gasket<br />
Cabinet<br />
Heat Sink<br />
Ambient<br />
Fan<br />
216 [8,51]<br />
256 [10,09]<br />
Features:<br />
- gasket certified <strong>ATEX</strong> Zone 2 T5<br />
- temperature sensor<br />
- safety switch / thermal fuse for over-temperature<br />
- drip pan on request
Technical Specifications ACAC <strong>600</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong><br />
Electric Data<br />
Nominal Capacity at +25°C (+77 °F) ambient and<br />
T = 0°C (0°F)<br />
Supply Voltage Ui<br />
Running Current Cooling Mode<br />
Running Current Heating Mode<br />
Maximum power consumption (not steady state)<br />
Max. Ambient Temperature<br />
Min. Ambient Temperature<br />
Enclosure Fan <strong>Air</strong> Flow<br />
Ambient Fan <strong>Air</strong> Flow<br />
Weight<br />
Ratings certified<br />
by TÜV Product Service, Germany<br />
Main Dimensions<br />
176 W (<strong>600</strong> <strong>BTU</strong> / hr)<br />
24 Vdc<br />
15 Adc continuous<br />
15 Adc continuous<br />
480 W @ 24Vdc<br />
+49°C (+120°F)<br />
-40°C (-40°F)<br />
250 m 3 /h (147.2 CFM)<br />
410 m 3 /h (241.3 CFM)<br />
9,4 kg (20,7 lb)<br />
CE, 3G EEX nA IIA T5 X<br />
H 254 mm x W 178 mm x D 244 mm<br />
(H 10” x W 7” x D 9.6”)<br />
Contact<br />
INHECO GmbH<br />
Fraunhoferstrasse 11<br />
82152 Martinsried<br />
Germany<br />
Phone: +49 (0)89 899593-101<br />
Fax: +49 (0)89 899593-149<br />