29.10.2014 Views

Air Conditioner ATEX 600 BTU Ex Proof - Inheco

Air Conditioner ATEX 600 BTU Ex Proof - Inheco

Air Conditioner ATEX 600 BTU Ex Proof - Inheco

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Thermoelectric <strong>Air</strong> <strong>Conditioner</strong><br />

ACAC <strong>600</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong><br />

Heating & Cooling Unit for hazardous environment<br />

<strong>Ex</strong>plosion <strong>Proof</strong> Rating <strong>ATEX</strong> Zone 2 T5<br />

Dust and Water Protection Standard IP55<br />

INHECO part number: 8700001


delta T (°F)<br />

delta T (°C)<br />

<br />

<br />

No Controller & Power Supply provided by INHECO<br />

<br />

Performance curve for ACAC <strong>600</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong><br />

Cooling Data<br />

ACAC <strong>600</strong> <strong>Air</strong> <strong>BTU</strong> <strong>Conditioner</strong> <strong>Ex</strong> <strong>Proof</strong> Heater (<strong>600</strong> <strong>BTU</strong>/hr) ACAC-180W<br />

10 °C<br />

0 °C<br />

-10 °C<br />

-20 °C<br />

+25 °C ambient<br />

+60 °C ambient<br />

-30 °C<br />

-40 °C<br />

-50 °C<br />

0 W 50 W 100 W 150 W 200 W 250 W<br />

Capacity (W)<br />

ACAC <strong>Air</strong> <strong>600</strong> <strong>Conditioner</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong> Heater (<strong>600</strong> ACAC-<strong>600</strong><strong>BTU</strong>/HR<br />

<strong>BTU</strong>/hr)<br />

10 °F<br />

-10 °F<br />

-30 °F<br />

-50 °F<br />

+77 °F ambient<br />

+140 °F ambient<br />

-70 °F<br />

-90 °F<br />

0 <strong>BTU</strong>/HR 100<br />

<strong>BTU</strong>/HR<br />

200<br />

<strong>BTU</strong>/HR<br />

300<br />

<strong>BTU</strong>/HR<br />

400<br />

<strong>BTU</strong>/HR<br />

500<br />

<strong>BTU</strong>/HR<br />

<strong>600</strong><br />

<strong>BTU</strong>/HR<br />

700<br />

<strong>BTU</strong>/HR<br />

800<br />

<strong>BTU</strong>/HR<br />

Capacity (<strong>BTU</strong>/HR)


delta T (°C)<br />

delta T (°F)<br />

Heating Data<br />

ACAC <strong>Air</strong> <strong>600</strong> <strong>Conditioner</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong> Heater (<strong>600</strong> ACAC-180W<br />

<strong>BTU</strong>/hr)<br />

10 °C<br />

0 °C<br />

-10 °C<br />

-20 °C<br />

+25 °C ambient<br />

+60 °C ambient<br />

-30 °C<br />

-40 °C<br />

-50 °C<br />

320 W 370 W 420 W 470 W 520 W<br />

Capacity (W)<br />

<strong>Air</strong> ACAC <strong>Conditioner</strong> <strong>600</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong> Heater (<strong>600</strong> ACAC-<strong>600</strong><strong>BTU</strong>/HR<br />

<strong>BTU</strong>/hr))<br />

10 °F<br />

-10 °F<br />

+77 °F ambient<br />

-30 °F<br />

+140 °F ambient<br />

-50 °F<br />

-70 °F<br />

-90 °F<br />

1100<br />

<strong>BTU</strong>/HR<br />

1200<br />

<strong>BTU</strong>/HR<br />

1300<br />

<strong>BTU</strong>/HR<br />

1400<br />

<strong>BTU</strong>/HR<br />

1500<br />

<strong>BTU</strong>/HR<br />

1<strong>600</strong><br />

<strong>BTU</strong>/HR<br />

1700<br />

<strong>BTU</strong>/HR<br />

1800<br />

<strong>BTU</strong>/HR<br />

1900<br />

<strong>BTU</strong>/HR<br />

Capacity (<strong>BTU</strong>/HR)


Dimensions ACAC <strong>600</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong><br />

Dimensions in mm [inch]<br />

256 [10,08]<br />

122,4 [4,82]<br />

Mounting screw<br />

thread (blind hole)<br />

Sensor Cabinet<br />

Heat Sink<br />

137 [5,40]<br />

178 [7,01]<br />

Cabinet<br />

Fan<br />

Conductor<br />

Bushing<br />

Threaded<br />

Cabinet<br />

Heat Sink<br />

Insulation<br />

Gasket<br />

Cabinet<br />

Heat Sink<br />

Ambient<br />

Fan<br />

216 [8,51]<br />

256 [10,09]<br />

Features:<br />

- gasket certified <strong>ATEX</strong> Zone 2 T5<br />

- temperature sensor<br />

- safety switch / thermal fuse for over-temperature<br />

- drip pan on request


Technical Specifications ACAC <strong>600</strong> <strong>BTU</strong> <strong>Ex</strong> <strong>Proof</strong><br />

Electric Data<br />

Nominal Capacity at +25°C (+77 °F) ambient and<br />

T = 0°C (0°F)<br />

Supply Voltage Ui<br />

Running Current Cooling Mode<br />

Running Current Heating Mode<br />

Maximum power consumption (not steady state)<br />

Max. Ambient Temperature<br />

Min. Ambient Temperature<br />

Enclosure Fan <strong>Air</strong> Flow<br />

Ambient Fan <strong>Air</strong> Flow<br />

Weight<br />

Ratings certified<br />

by TÜV Product Service, Germany<br />

Main Dimensions<br />

176 W (<strong>600</strong> <strong>BTU</strong> / hr)<br />

24 Vdc<br />

15 Adc continuous<br />

15 Adc continuous<br />

480 W @ 24Vdc<br />

+49°C (+120°F)<br />

-40°C (-40°F)<br />

250 m 3 /h (147.2 CFM)<br />

410 m 3 /h (241.3 CFM)<br />

9,4 kg (20,7 lb)<br />

CE, 3G EEX nA IIA T5 X<br />

H 254 mm x W 178 mm x D 244 mm<br />

(H 10” x W 7” x D 9.6”)<br />

Contact<br />

INHECO GmbH<br />

Fraunhoferstrasse 11<br />

82152 Martinsried<br />

Germany<br />

Phone: +49 (0)89 899593-101<br />

Fax: +49 (0)89 899593-149<br />

e-mail: sales@inheco.com<br />

Website:<br />

www.inheco.com