You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Consumer units<br />
<strong>designed</strong><br />
<strong>for</strong> <strong>modern</strong><br />
<strong>living</strong><br />
THE GLOBAL SPECIALIST<br />
IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
DESIGN<br />
is all around us<br />
Modern interiors revolve around minimalist, sophisticated<br />
interior design themes consisting of clean lines, neutral<br />
tones and maximised use of space.<br />
Designed to blend in with the <strong>modern</strong> environment,<br />
<strong>Legrand</strong>’s new consumer units are perfectly placed to<br />
stand the test of time.
CONSUMER UNITS...<br />
DESIGN OF THE TIMES<br />
<strong>Legrand</strong>’s insulated and metal consumer units are<br />
manufactured to white RAL 9003, creating a stylish,<br />
understated inish which blends in perfectly with<br />
<strong>modern</strong> interiors.<br />
MEETING THE DEMANDS<br />
OF MODERN LIVING<br />
There is an increasing demand <strong>for</strong> additional electrical<br />
circuits due to the popularity of smart home solutions,<br />
and a growing requirement <strong>for</strong> dedicated circuits <strong>for</strong><br />
items such as hard wired smoke detectors, photovoltaic<br />
panels and electric vehicle charging points.<br />
<strong>Legrand</strong>’s consumer units are available with up to 22<br />
ways, including a custom build option which offers<br />
complete choice and lexibility.<br />
Discreet semi-flush mounting option available<br />
Increasing popularity of home automation and control<br />
Growth in requirement <strong>for</strong> dedicated circuits<br />
The demands of <strong>modern</strong><br />
<strong>living</strong> have led to the<br />
requirement <strong>for</strong> an<br />
increased number of<br />
electrical circuits<br />
WWW.LEGRAND.CO.UK<br />
3
design<br />
is more than<br />
skin deep<br />
With an array of design innovations making<br />
them easy to install, <strong>Legrand</strong>’s consumer<br />
units save valuable time and money during<br />
installation... allowing you to relect on the<br />
generous wiring space and the all-round<br />
extra protection.<br />
Rigid base with<br />
multiple cut-outs<br />
Removable terminal<br />
holders with screws in<br />
backed-off position<br />
White RAL 9003<br />
case with high ire<br />
retardancy.<br />
Self extinguishing<br />
at 750°C<br />
Removable<br />
pan assembly<br />
Cut-to-length busbar<br />
<strong>for</strong> lexible on-site<br />
coniguration<br />
Insulated<br />
shield<br />
Hinged door conceals<br />
protection devices and<br />
labelling<br />
Rail positioned<br />
<strong>for</strong> maximum<br />
cabling space<br />
<strong>Legrand</strong> consumer units<br />
are itted as standard with<br />
80 A RCDs<br />
4
Guide to choosing the right<br />
consumer unit coniguration<br />
under the 17th Edition<br />
Dual RCD split load with dedicated main switch ways -<br />
Select MCBs and RCBOs to complete installation<br />
EASY ACCESS<br />
Features include a<br />
removable pan assembly,<br />
earth terminal holder that<br />
simply clips into place, and<br />
multiple cut-outs to the<br />
unit’s back, bottom, top<br />
and sides.<br />
Dual RCD split load -<br />
Select MCBs to complete installation<br />
ON-SITE<br />
CONFIGURATION<br />
For lexible on-site<br />
coniguration, simply cut<br />
busbar to the required<br />
length.<br />
Main switch incomer -<br />
Select RCBOs to complete installation<br />
PROTECTION<br />
OPTIONS<br />
<strong>Legrand</strong> has everything<br />
you need to complete<br />
your installation: isolating<br />
switches, RCDs, NEW RX 3<br />
MCBs and RCBOs.<br />
RCD incomer -<br />
Select MCBs to complete installation<br />
Custom build -<br />
Maximum lexibility<br />
WWW.LEGRAND.CO.UK<br />
5
consumer units<br />
insulated and metal<br />
NEW<br />
Insulated consumer units<br />
Con<strong>for</strong>m to BS EN 60439-3. IP 30. RAL 9003. White colour. Plain door opens downwards<br />
Supplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plate<br />
Factory fitted link leads <strong>for</strong> both neutral and live connections. Configurable outgoing ways<br />
Self-extinguishing at 750 °C. UL 94 V2 material <strong>for</strong> improved flame retardancy. Robust thermoplastic construction. 4 fixing holes<br />
Dimensions<br />
p. 11<br />
High integrity dual RCD split<br />
load with 2 unprotected ways<br />
100 A main switch and<br />
2 x 80 A 30 mA RCD<br />
Dual RCD split load<br />
100 A main switch and<br />
2 x 80 A 30 mA RCD<br />
Dual RCD split load -<br />
semi flush<br />
100 A main switch and<br />
2 x 80 A 30 mA RCD<br />
Total outgoing ways<br />
2 4 6 8 10 12 14 16 18 20 22<br />
– – – – 6075 70 – – 6075 71 – – –<br />
– – – – 6075 57 – – 6075 58 – – –<br />
– – – – 8204 10 – – 8204 09 – – –<br />
Main switch incomer<br />
63 A main switch<br />
6075 63 – – – – – – – – – –<br />
Main switch incomer<br />
100 A main switch<br />
– – 6075 59 – 6075 60 – 6075 66 – – 6075 67 –<br />
RCD incomer<br />
80 A 30 mA RCD<br />
– – 6075 64 – 6075 65 – – – – – –<br />
Custom build<br />
– 6075 68 – 6075 61 – 6075 62 – – – – –<br />
Metal consumer units<br />
Con<strong>for</strong>m to BS EN 60439-3. IP 30. RAL 9003. White colour. Plain door opens downwards<br />
Supplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plate<br />
Factory fitted link leads <strong>for</strong> both neutral and live connections. Configurable outgoing ways<br />
Pre-galvanised steel <strong>for</strong> strength and rigidity. Epoxy/polyester powder coated base and lid<br />
Dimensions<br />
p. 12<br />
Dual RCD split load<br />
100 A main switch and<br />
2 x 80 A 30 mA RCD<br />
Total outgoing ways<br />
6 8 10 12 14 16 18 20 22<br />
– – 6065 57 – – 6065 58 – – –<br />
Main switch incomer<br />
100 A main switch<br />
6065 59 – 6065 60 – – – – – –<br />
Custom build<br />
– 6065 61 – 6065 62 – 6065 50 – – 6065 51<br />
6
protection devices<br />
MCBs and RCBOs<br />
RX 3 MCBs - 6 kA<br />
Breaking capacity :<br />
6 kA to BS EN 60898-1<br />
RX 3 residential MCBs - 6 kA<br />
Single pole - 230/400 V±<br />
RCBOs (combined MCB/RCD)<br />
Single pole and neutral - 240 V±<br />
RCBOs (combined MCB/RCD)<br />
Breaking capacity :<br />
10 kA to BS EN 61009-1<br />
RCD type AC con<strong>for</strong>m to<br />
BS EN 61009-1<br />
Terminal capacity :<br />
rigid conductor 35 mm 2<br />
flexible conductor 25 mm 2 4022 70<br />
6064 18<br />
Nominal rating (In)<br />
Pack<br />
Qty<br />
Number of<br />
17 . 5 mm<br />
modules<br />
B curve<br />
C curve<br />
Number of<br />
17 . 5 mm<br />
modules<br />
30 mA<br />
B curve<br />
6 A<br />
10 1 4022 70 4023 10 1 6064 16<br />
10 A<br />
10 1 4022 71 4023 11 1 6064 17<br />
16 A<br />
10 1 4022 72 4023 13 1 6064 18<br />
20 A<br />
10 1 4022 73 4023 14 1 6064 19<br />
25 A<br />
10 1 4022 74 4023 15 – –<br />
32 A<br />
10 1 4022 75 4023 16 1 6064 20<br />
40 A<br />
10 1 4022 76 4023 17 1 6064 21<br />
50 A<br />
10 1 4022 77 4023 18 1 6064 28<br />
63 A<br />
10 1 4022 78 4023 19 – –<br />
7
insulated consumer units<br />
surface mounting<br />
6075 71<br />
6075 57<br />
6075 63 6075 64<br />
Dimensions p.11<br />
Con<strong>for</strong>m to BS EN 60439-3. IP 30. RAL 9003 - white colour<br />
Self-extinguishing at 750 °C - UL 94 V2 material <strong>for</strong> improved flame retardancy<br />
Robust, rigid thermoplastic construction with 4 fixing holes<br />
Door opens downwards<br />
Supplied with neutral and earth terminals completely assembled<br />
Supplied with 5 module spare blank plate (except 4 module unit)<br />
MCBs to be ordered separately, (see p. 10)<br />
Rigid base with multiple cut-outs<br />
Removable terminal holders with screws in backed-off position<br />
Insulated shield<br />
Cut-to-length busbar<br />
Removable pan assembly<br />
New<br />
image<br />
VC to<br />
supply<br />
RX 3 residential MCBs and<br />
single module RCBOs p. 10<br />
Pack<br />
NEW<br />
Cat. Nos. Insulated high integrity dual RCD split load<br />
with 2 unprotected ways - surface mounting<br />
16 module unit (8 + 2 ways available)<br />
1 6075 70 With 100 A main switch and 2 x 80 A 30 mA RCD<br />
22 module unit (13 + 3 ways available)<br />
1 6075 71 With 100 A main switch and 2 x 80 A 30 mA RCD<br />
NEW<br />
Insulated dual RCD split load - surface<br />
mounting<br />
16 module unit (10 ways available)<br />
1 6075 57 With 100 A main switch and 2 x 80 A 30 mA RCD<br />
22 module unit (16 ways available)<br />
1 6075 58 With 100 A main switch and 2 x 80 A 30 mA RCD<br />
NEW<br />
Insulated dual RCD split load - semi-flush<br />
mounting<br />
16 module unit (10 ways available)<br />
1 8204 10 With 100 A main switch and 2 x 80 A 30 mA RCD<br />
22 module unit (16 ways available)<br />
1 8204 09 With 100 A main switch and 2 x 80 A 30 mA RCD<br />
Insulated with incomer - surface mounting<br />
4 module unit<br />
1 6075 63 With 63 A main switch (2 ways available)<br />
8 module unit<br />
1 6075 59 With 100 A main switch (6 ways available)<br />
1 6075 64 With 80 A 30 mA RCD (6 ways available)<br />
12 module unit<br />
1 6075 60 With 100 A main switch (10 ways available)<br />
1 6075 65 With 80 A 30 mA RCD (10 ways available)<br />
16 module unit<br />
1 6075 66 With 100 A main switch (14 ways available)<br />
22 module unit<br />
1 6075 67 With 100 A main switch (20 ways available)<br />
Pack<br />
Cat. Nos. Insulated custom build - surface mounting<br />
Allow several configurations when using kits and<br />
incomers (isolating switches, RCDs, RCBOs)<br />
For kits, (see p. 215)<br />
For incomers and outgoing devices, (see p. 10)<br />
1 6075 68 4 modules available<br />
1 6075 61 8 modules available<br />
1 6075 62 12 modules available<br />
NEW<br />
Accessories <strong>for</strong> surface mounting units<br />
Lockable brackets<br />
1 8218 57 For 16 module unit<br />
1 8218 58 For 22 module unit<br />
NEW<br />
Padlock<br />
3 4063 13 Ø 4 m<br />
Accessories <strong>for</strong> semi-flush mounting units<br />
Lockable brackets<br />
1 8204 71 For 16 module unit<br />
1 8204 72 For 22 module unit<br />
NEW<br />
Padlock<br />
3 4063 13 Ø 4 m<br />
8
metal consumer units<br />
surface mounting<br />
NEW<br />
Available May 2013<br />
accessories<br />
<strong>for</strong> insulated and metal consumer units<br />
RX 3 residential MCBs and<br />
single module RCBOs p. 10<br />
6065 62<br />
Dimensions p. 12<br />
Con<strong>for</strong>m to BS EN 60439-3. IP 30. RAL 9003 - white colour<br />
Pre-galvanised steel <strong>for</strong> strength and rigidity<br />
Door opens downwards<br />
Supplied with neutral and earth terminals completely assembled<br />
Supplied with 5 module spare blank plate<br />
MCBs to be ordered separately, (see p. 10)<br />
Pack<br />
Cat. Nos. Metal dual RCD split load - surface mounting<br />
16 module unit (10 ways available)<br />
1 6065 57 With 100 A main switch and 2 x 80 A 30 mA RCD<br />
22 module unit (16 ways available)<br />
1 6065 58 With 100 A main switch and 2 x 80 A 30 mA RCD<br />
Metal with incomer - surface mounting<br />
Epoxy/polyester powder coated base and lid<br />
Stand-off feet complete with keyhole fixing<br />
8 module unit<br />
1 6065 59 With 100 A main switch (6 ways available)<br />
12 module unit<br />
1 6065 60 With 100 A main switch (10 ways available)<br />
Metal custom build - surface mounting<br />
Epoxy/polyester powder coated base and lid<br />
Stand-off feet complete with keyhole fixing<br />
Allow several configurations when using kits and<br />
incomers (isolating switches, RCDs, RCBOs)<br />
For kits, (see opposite)<br />
For incomers and outgoing devices, (see p. 10)<br />
1 6065 61 8 modules available<br />
1 6065 62 12 modules available<br />
1 6065 50 16 modules available<br />
1 6065 51 22 modules available<br />
Pack<br />
Cat. Nos. Accessories<br />
Incomer or dual tariff kit<br />
1 6075 19 Comprises : 1 flexible neutral (blue) lead<br />
1 rigid neutral link<br />
Split load kit<br />
1 6075 39 Comprises : 1 flexible live (brown) lead<br />
1 flexible neutral (blue) lead<br />
2 rigid neutral links<br />
Split load dual tariff kit (<strong>for</strong> insulated units only)<br />
1 6075 49 Comprises : 1 flexible live (brown) lead<br />
2 flexible neutral (blue) leads<br />
2 rigid neutral links<br />
1 neutral terminal<br />
NEW<br />
Spare blank plate RAL 9003<br />
20 0016 60 5 modules - white colour<br />
Spare blank plate RAL 9010<br />
10 0016 64 18 module, separable by single or half modules<br />
Spare busbar<br />
5 6075 99 21 prongs<br />
NEW<br />
Spacing elements<br />
10 4063 07 0·5 module<br />
Locking device <strong>for</strong> MCBs and RCDs<br />
2 4063 03 Locking attachment <strong>for</strong> Ø 4 mm and<br />
Ø 6 mm padlocks<br />
NEW<br />
Padlock <strong>for</strong> MCBs and RCDs<br />
3 4063 13 Padlock Ø 4 m<br />
Spare terminal block<br />
1 8204 07 13 hole<br />
Self-adhesive label holder<br />
10 0049 96 Width : 16 mm<br />
Width available <strong>for</strong> marking : 12 mm<br />
Length 530 mm (24 modules)<br />
0049 96<br />
9
protection and control devices<br />
4022 70<br />
6064 18<br />
4020 27 4064 55<br />
4125 44 4130 91<br />
Pack Cat. Nos. RX 3 residential MCBs - 6 kA<br />
Breaking capacity : 6 kA to BS EN 60898-1<br />
Single pole - 230/400 V±<br />
B curve C curve Nominal rating Number of<br />
(In)<br />
17·5 mm modules<br />
10 4022 70 4023 10 6 A 1<br />
10 4022 71 4023 11 10 A 1<br />
10 4022 72 4023 13 16 A 1<br />
10 4022 73 4023 14 20 A 1<br />
10 4022 74 4023 15 25 A 1<br />
10 4022 75 4023 16 32 A 1<br />
10 4022 76 4023 17 40 A 1<br />
10 4022 77 4023 18 50 A 1<br />
10 4022 78 4023 19 63 A 1<br />
DX 3 multi-purpose MCBs - 10 kA<br />
Breaking capacity : 10 kA to BS EN 60947-2<br />
Single pole - 230/400 V±<br />
B C B curve C curve Nominal rating Number of<br />
(In)<br />
17·5 mm modules<br />
1 1 4074 29 4076 66 6 A 1<br />
1 10 4074 30 4076 68 10 A 1<br />
1 10 4074 32 4076 70 16 A 1<br />
1 1 4074 33 4076 71 20 A 1<br />
1 1 4074 35 4076 73 32 A 1<br />
1 1 4074 36 4076 74 40 A 1<br />
1 1 4074 37 4076 75 50 A 1<br />
1 1 4074 38 4076 76 63 A 1<br />
NEW<br />
RCBOs (combined MCB/RCD) -<br />
Single module<br />
Breaking capacity : 10 kA to BS EN 61009-1<br />
RCD type AC con<strong>for</strong>m to BS EN 61009-1<br />
Terminal capacity : rigid conductor 35 mm 2<br />
flexible conductor 25 mm 2<br />
Single pole and neutral - 240 V±<br />
B curve Nominal rating Number of<br />
(In)<br />
17·5 mm modules<br />
30 mA<br />
1 6064 16 6 A 1<br />
1 6064 17 10 A 1<br />
1 6064 18 16 A 1<br />
1 6064 19 20 A 1<br />
1 6064 20 32 A 1<br />
1 6064 21 40 A 1<br />
1 6064 28 50 A 1<br />
Pack<br />
Cat. Nos. RX 3 residual current devices (RCDs)<br />
Con<strong>for</strong>m to BS EN 61008-1<br />
Terminal capacity : rigid conductor 35 mm 2<br />
flexible conductor 25 mm 2<br />
Double pole 230 V±<br />
Type AC Nominal rating Number of<br />
(In)<br />
17·5 mm modules<br />
30 mA<br />
1 4020 24 25 A 2<br />
1 4020 25 40 A 2<br />
1 4020 26 63 A 2<br />
1 4020 27 80 A 2<br />
100 mA<br />
1 4020 28 25 A 2<br />
1 4020 29 40 A 2<br />
1 4020 30 63 A 2<br />
NEW<br />
DX 3 Isolating switches<br />
Con<strong>for</strong>m to BS EN 60947-3, IEC 60669-1<br />
Usage : AC 22 according to IEC 60947-3<br />
Red handle<br />
Double break contacts, padlockable<br />
50 mm 2 capacity shielded terminals<br />
Number of<br />
17·5 mm modules<br />
5 4064 53 63 A double pole 2<br />
5 4064 55 100 A double pole 2<br />
NEW<br />
NEW<br />
CX 3 Contactor with 230 V± coil<br />
Con<strong>for</strong>ms to BS EN 61095<br />
Double pole (L + N) 250 V±<br />
230 V± coil circuit Type of Number of<br />
I max. contact 17·5 mm<br />
modules<br />
230 V<br />
1 4125 44 25 A 2 N/O 1<br />
NEW<br />
For other contactors, see current Industrial and<br />
Power Protection catalogue<br />
Bell trans<strong>for</strong>mers<br />
d<br />
Con<strong>for</strong>m to IEC/EN 61558-2-8<br />
Supplied with label holder<br />
Protected against overloads and short circuits<br />
Power to 8 V-12 V or 24 V access control devices<br />
such as bells and chimes<br />
Possibility <strong>for</strong> supply busbars to run through<br />
(Cat. Nos. 4130 90/91)<br />
Number<br />
Secondary (V) Rating (A) Power (VA) of 17·5 mm<br />
modules<br />
230 V / 8 V<br />
1 4130 90 8 V± 0·5 A 4 VA 2<br />
230 V / 12 V - 8 V<br />
1 4130 91 12/8 V± 0·66/1 A 8 VA 2<br />
230 V / 24 V - 12 V<br />
1 4130 93 24/12 V± 1/1·5 A 24/18 VA 4<br />
10
insulated consumer units<br />
surface mounting<br />
n Insulated - surface mounting dimensions (mm)<br />
A 110<br />
n 8 module unit<br />
Back box fixing centres and cable entries (mm)<br />
View from<br />
above<br />
2 cut-outs<br />
50 x 50<br />
2 cut-outs<br />
40 x 50<br />
50<br />
B<br />
195<br />
20<br />
40<br />
50<br />
6 cut-outs<br />
20 x 25 8 cut-outs<br />
25 x 25<br />
View from<br />
sides<br />
2 cut-outs<br />
20 x 25<br />
Modules A (mm) B (mm)<br />
4 140 225<br />
225<br />
114<br />
162<br />
8 212 225<br />
12 298 225<br />
14/16 370 225<br />
20/22 478 225<br />
6 cut-outs 20 x 25<br />
n 4 module unit<br />
Back box fixing centres and cable entries (mm)<br />
View from<br />
below<br />
View from<br />
above<br />
1 cut-out<br />
50 x 50<br />
1 cut-out<br />
40 x 50<br />
40<br />
20<br />
50<br />
n 12 module unit<br />
Back box fixing centres and cable entries (mm)<br />
4 cut-outs<br />
20 x 25<br />
4 cut-outs<br />
25 x 25<br />
View from<br />
sides<br />
View from<br />
above<br />
2 cut-outs<br />
50 x 50<br />
2 cut-outs<br />
40 x 50<br />
225<br />
114<br />
2 cut-outs<br />
20 x 25<br />
40<br />
20<br />
90<br />
225<br />
180<br />
6 cut-outs<br />
20 x 25<br />
2 cut-outs<br />
20 x 18 . 5<br />
22 cut-outs<br />
25 x 20<br />
50<br />
View from<br />
sides<br />
2 cut-outs<br />
20 x 25<br />
4 cut-outs 20 x 25<br />
268<br />
View from<br />
below<br />
2 cut-outs 20 x 25<br />
2 cut-outs 20 x 18 . 5<br />
View from<br />
below<br />
11
insulated consumer units<br />
surface mounting (continued)<br />
metal consumer units<br />
surface mounting<br />
n 14/16 module unit<br />
Back box fixing centres and cable entries (mm)<br />
View from<br />
above<br />
2 cut-outs 50 x 50 2 cut-outs 40 x 50<br />
n Metal - surface mounting dimensions (mm)<br />
A 113<br />
20<br />
40<br />
B<br />
50<br />
10 cut-outs 20 x 25<br />
30 cut-outs 25 x 20<br />
View from<br />
sides<br />
225<br />
180<br />
2 cut-outs<br />
20 x 25<br />
Modules A (mm) B (mm)<br />
8 219 235<br />
50<br />
200<br />
12 305 235<br />
340<br />
16 377 235<br />
22 485 235<br />
8 cut-outs 20 x 25<br />
n 8 module unit<br />
Back box fixing centres and cable entries (mm)<br />
View from<br />
below<br />
View from<br />
above<br />
4 cut-outs Ø 32<br />
n 20/22 module unit<br />
Back box fixing centres and cable entries (mm)<br />
100<br />
View from<br />
above<br />
2 cut-outs 50 x 50 2 cut-outs 40 x 50<br />
1 obround<br />
cut-out 100 x 50<br />
40<br />
20<br />
2 cut-outs 20 x 22 12 cut-outs 20 x 25<br />
50<br />
95 80<br />
4<br />
Ø 5<br />
42 cut-outs 25 x 20<br />
View from<br />
sides<br />
Ø 9<br />
3<br />
2 cut-outs<br />
20 x 25<br />
View from<br />
below<br />
225<br />
180<br />
1 cut-out Ø 25<br />
448<br />
2 cut-outs 20 x 22<br />
10 cut-outs 20 x 25<br />
View from<br />
below<br />
12
metal consumer units<br />
surface mounting (continued)<br />
n 12 module unit<br />
Back box fixing centres and cable entries (mm)<br />
4 cut-outs Ø 32<br />
n 22 module unit<br />
Back box fixing centres and cable entries (mm)<br />
4 cut-outs Ø 25<br />
View from<br />
above<br />
View from<br />
above<br />
175<br />
350<br />
120<br />
95 80<br />
1 obround<br />
cut-out 100 x 50<br />
95 80<br />
2 obround<br />
cut-outs 100 x 50<br />
100<br />
View from<br />
below<br />
275<br />
8 cut-outs Ø 20<br />
4 cut-outs Ø 32<br />
n 16 module unit<br />
Back box fixing centres and cable entries (mm)<br />
4 cut-outs Ø 20<br />
250<br />
120<br />
2 obround<br />
cut-outs 100 x 50<br />
95 80<br />
2 cut-outs Ø 20<br />
2 cut-outs Ø 25<br />
View from<br />
below<br />
View from<br />
above<br />
175<br />
View from<br />
below<br />
4 cut-outs Ø 25<br />
4 cut-outs Ø 32<br />
13
Contact details<br />
United Kingdom<br />
Great King Street North,<br />
Birmingham, B19 2LF<br />
Customer Services:<br />
Tel: +44 (0) 845 605 4333 Fax: +44 (0) 845 605 4334<br />
E-mail: legrand.sales@legrand.co.uk<br />
Quotations and Technical Support:<br />
Tel: +44 (0) 870 608 9020 Fax: +44 (0) 870 608 9021<br />
E-mail: uk-wdsales@legrand.co.uk<br />
Republic of Ireland:<br />
Tel: 01 295 9673 Fax: 01 295 4671<br />
E-mail: legrand.sales@legrand.co.uk<br />
Distributor:<br />
Head ofice (UK and Ireland):<br />
<strong>Legrand</strong> Electric Limited<br />
Great King Street North, Birmingham, B19 2LF<br />
Tel: 0870 608 9000 Fax: 0870 608 9004<br />
Website: www.legrand.co.uk<br />
Consumer unit product guide 04/2013.PDF<br />
This document is printed on sustainably sourced paper. Please recycle.<br />
The <strong>Legrand</strong> logo is a registered trademark<br />
of the <strong>Legrand</strong> group of companies.