Consumer units<br />

<strong>designed</strong><br />

<strong>for</strong> <strong>modern</strong><br />

<strong>living</strong><br />

THE GLOBAL SPECIALIST<br />

IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES


DESIGN<br />

is all around us<br />

Modern interiors revolve around minimalist, sophisticated<br />

interior design themes consisting of clean lines, neutral<br />

tones and maximised use of space.<br />

Designed to blend in with the <strong>modern</strong> environment,<br />

<strong>Legrand</strong>’s new consumer units are perfectly placed to<br />

stand the test of time.


CONSUMER UNITS...<br />

DESIGN OF THE TIMES<br />

<strong>Legrand</strong>’s insulated and metal consumer units are<br />

manufactured to white RAL 9003, creating a stylish,<br />

understated inish which blends in perfectly with<br />

<strong>modern</strong> interiors.<br />

MEETING THE DEMANDS<br />

OF MODERN LIVING<br />

There is an increasing demand <strong>for</strong> additional electrical<br />

circuits due to the popularity of smart home solutions,<br />

and a growing requirement <strong>for</strong> dedicated circuits <strong>for</strong><br />

items such as hard wired smoke detectors, photovoltaic<br />

panels and electric vehicle charging points.<br />

<strong>Legrand</strong>’s consumer units are available with up to 22<br />

ways, including a custom build option which offers<br />

complete choice and lexibility.<br />

Discreet semi-flush mounting option available<br />

Increasing popularity of home automation and control<br />

Growth in requirement <strong>for</strong> dedicated circuits<br />

The demands of <strong>modern</strong><br />

<strong>living</strong> have led to the<br />

requirement <strong>for</strong> an<br />

increased number of<br />

electrical circuits<br />

WWW.LEGRAND.CO.UK<br />

3


design<br />

is more than<br />

skin deep<br />

With an array of design innovations making<br />

them easy to install, <strong>Legrand</strong>’s consumer<br />

units save valuable time and money during<br />

installation... allowing you to relect on the<br />

generous wiring space and the all-round<br />

extra protection.<br />

Rigid base with<br />

multiple cut-outs<br />

Removable terminal<br />

holders with screws in<br />

backed-off position<br />

White RAL 9003<br />

case with high ire<br />

retardancy.<br />

Self extinguishing<br />

at 750°C<br />

Removable<br />

pan assembly<br />

Cut-to-length busbar<br />

<strong>for</strong> lexible on-site<br />

coniguration<br />

Insulated<br />

shield<br />

Hinged door conceals<br />

protection devices and<br />

labelling<br />

Rail positioned<br />

<strong>for</strong> maximum<br />

cabling space<br />

<strong>Legrand</strong> consumer units<br />

are itted as standard with<br />

80 A RCDs<br />

4


Guide to choosing the right<br />

consumer unit coniguration<br />

under the 17th Edition<br />

Dual RCD split load with dedicated main switch ways -<br />

Select MCBs and RCBOs to complete installation<br />

EASY ACCESS<br />

Features include a<br />

removable pan assembly,<br />

earth terminal holder that<br />

simply clips into place, and<br />

multiple cut-outs to the<br />

unit’s back, bottom, top<br />

and sides.<br />

Dual RCD split load -<br />

Select MCBs to complete installation<br />

ON-SITE<br />

CONFIGURATION<br />

For lexible on-site<br />

coniguration, simply cut<br />

busbar to the required<br />

length.<br />

Main switch incomer -<br />

Select RCBOs to complete installation<br />

PROTECTION<br />

OPTIONS<br />

<strong>Legrand</strong> has everything<br />

you need to complete<br />

your installation: isolating<br />

switches, RCDs, NEW RX 3<br />

MCBs and RCBOs.<br />

RCD incomer -<br />

Select MCBs to complete installation<br />

Custom build -<br />

Maximum lexibility<br />

WWW.LEGRAND.CO.UK<br />

5


consumer units<br />

insulated and metal<br />

NEW<br />

Insulated consumer units<br />

Con<strong>for</strong>m to BS EN 60439-3. IP 30. RAL 9003. White colour. Plain door opens downwards<br />

Supplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plate<br />

Factory fitted link leads <strong>for</strong> both neutral and live connections. Configurable outgoing ways<br />

Self-extinguishing at 750 °C. UL 94 V2 material <strong>for</strong> improved flame retardancy. Robust thermoplastic construction. 4 fixing holes<br />

Dimensions<br />

p. 11<br />

High integrity dual RCD split<br />

load with 2 unprotected ways<br />

100 A main switch and<br />

2 x 80 A 30 mA RCD<br />

Dual RCD split load<br />

100 A main switch and<br />

2 x 80 A 30 mA RCD<br />

Dual RCD split load -<br />

semi flush<br />

100 A main switch and<br />

2 x 80 A 30 mA RCD<br />

Total outgoing ways<br />

2 4 6 8 10 12 14 16 18 20 22<br />

– – – – 6075 70 – – 6075 71 – – –<br />

– – – – 6075 57 – – 6075 58 – – –<br />

– – – – 8204 10 – – 8204 09 – – –<br />

Main switch incomer<br />

63 A main switch<br />

6075 63 – – – – – – – – – –<br />

Main switch incomer<br />

100 A main switch<br />

– – 6075 59 – 6075 60 – 6075 66 – – 6075 67 –<br />

RCD incomer<br />

80 A 30 mA RCD<br />

– – 6075 64 – 6075 65 – – – – – –<br />

Custom build<br />

– 6075 68 – 6075 61 – 6075 62 – – – – –<br />

Metal consumer units<br />

Con<strong>for</strong>m to BS EN 60439-3. IP 30. RAL 9003. White colour. Plain door opens downwards<br />

Supplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plate<br />

Factory fitted link leads <strong>for</strong> both neutral and live connections. Configurable outgoing ways<br />

Pre-galvanised steel <strong>for</strong> strength and rigidity. Epoxy/polyester powder coated base and lid<br />

Dimensions<br />

p. 12<br />

Dual RCD split load<br />

100 A main switch and<br />

2 x 80 A 30 mA RCD<br />

Total outgoing ways<br />

6 8 10 12 14 16 18 20 22<br />

– – 6065 57 – – 6065 58 – – –<br />

Main switch incomer<br />

100 A main switch<br />

6065 59 – 6065 60 – – – – – –<br />

Custom build<br />

– 6065 61 – 6065 62 – 6065 50 – – 6065 51<br />

6


protection devices<br />

MCBs and RCBOs<br />

RX 3 MCBs - 6 kA<br />

Breaking capacity :<br />

6 kA to BS EN 60898-1<br />

RX 3 residential MCBs - 6 kA<br />

Single pole - 230/400 V±<br />

RCBOs (combined MCB/RCD)<br />

Single pole and neutral - 240 V±<br />

RCBOs (combined MCB/RCD)<br />

Breaking capacity :<br />

10 kA to BS EN 61009-1<br />

RCD type AC con<strong>for</strong>m to<br />

BS EN 61009-1<br />

Terminal capacity :<br />

rigid conductor 35 mm 2<br />

flexible conductor 25 mm 2 4022 70<br />

6064 18<br />

Nominal rating (In)<br />

Pack<br />

Qty<br />

Number of<br />

17 . 5 mm<br />

modules<br />

B curve<br />

C curve<br />

Number of<br />

17 . 5 mm<br />

modules<br />

30 mA<br />

B curve<br />

6 A<br />

10 1 4022 70 4023 10 1 6064 16<br />

10 A<br />

10 1 4022 71 4023 11 1 6064 17<br />

16 A<br />

10 1 4022 72 4023 13 1 6064 18<br />

20 A<br />

10 1 4022 73 4023 14 1 6064 19<br />

25 A<br />

10 1 4022 74 4023 15 – –<br />

32 A<br />

10 1 4022 75 4023 16 1 6064 20<br />

40 A<br />

10 1 4022 76 4023 17 1 6064 21<br />

50 A<br />

10 1 4022 77 4023 18 1 6064 28<br />

63 A<br />

10 1 4022 78 4023 19 – –<br />

7


insulated consumer units<br />

surface mounting<br />

6075 71<br />

6075 57<br />

6075 63 6075 64<br />

Dimensions p.11<br />

Con<strong>for</strong>m to BS EN 60439-3. IP 30. RAL 9003 - white colour<br />

Self-extinguishing at 750 °C - UL 94 V2 material <strong>for</strong> improved flame retardancy<br />

Robust, rigid thermoplastic construction with 4 fixing holes<br />

Door opens downwards<br />

Supplied with neutral and earth terminals completely assembled<br />

Supplied with 5 module spare blank plate (except 4 module unit)<br />

MCBs to be ordered separately, (see p. 10)<br />

Rigid base with multiple cut-outs<br />

Removable terminal holders with screws in backed-off position<br />

Insulated shield<br />

Cut-to-length busbar<br />

Removable pan assembly<br />

New<br />

image<br />

VC to<br />

supply<br />

RX 3 residential MCBs and<br />

single module RCBOs p. 10<br />

Pack<br />

NEW<br />

Cat. Nos. Insulated high integrity dual RCD split load<br />

with 2 unprotected ways - surface mounting<br />

16 module unit (8 + 2 ways available)<br />

1 6075 70 With 100 A main switch and 2 x 80 A 30 mA RCD<br />

22 module unit (13 + 3 ways available)<br />

1 6075 71 With 100 A main switch and 2 x 80 A 30 mA RCD<br />

NEW<br />

Insulated dual RCD split load - surface<br />

mounting<br />

16 module unit (10 ways available)<br />

1 6075 57 With 100 A main switch and 2 x 80 A 30 mA RCD<br />

22 module unit (16 ways available)<br />

1 6075 58 With 100 A main switch and 2 x 80 A 30 mA RCD<br />

NEW<br />

Insulated dual RCD split load - semi-flush<br />

mounting<br />

16 module unit (10 ways available)<br />

1 8204 10 With 100 A main switch and 2 x 80 A 30 mA RCD<br />

22 module unit (16 ways available)<br />

1 8204 09 With 100 A main switch and 2 x 80 A 30 mA RCD<br />

Insulated with incomer - surface mounting<br />

4 module unit<br />

1 6075 63 With 63 A main switch (2 ways available)<br />

8 module unit<br />

1 6075 59 With 100 A main switch (6 ways available)<br />

1 6075 64 With 80 A 30 mA RCD (6 ways available)<br />

12 module unit<br />

1 6075 60 With 100 A main switch (10 ways available)<br />

1 6075 65 With 80 A 30 mA RCD (10 ways available)<br />

16 module unit<br />

1 6075 66 With 100 A main switch (14 ways available)<br />

22 module unit<br />

1 6075 67 With 100 A main switch (20 ways available)<br />

Pack<br />

Cat. Nos. Insulated custom build - surface mounting<br />

Allow several configurations when using kits and<br />

incomers (isolating switches, RCDs, RCBOs)<br />

For kits, (see p. 215)<br />

For incomers and outgoing devices, (see p. 10)<br />

1 6075 68 4 modules available<br />

1 6075 61 8 modules available<br />

1 6075 62 12 modules available<br />

NEW<br />

Accessories <strong>for</strong> surface mounting units<br />

Lockable brackets<br />

1 8218 57 For 16 module unit<br />

1 8218 58 For 22 module unit<br />

NEW<br />

Padlock<br />

3 4063 13 Ø 4 m<br />

Accessories <strong>for</strong> semi-flush mounting units<br />

Lockable brackets<br />

1 8204 71 For 16 module unit<br />

1 8204 72 For 22 module unit<br />

NEW<br />

Padlock<br />

3 4063 13 Ø 4 m<br />

8


metal consumer units<br />

surface mounting<br />

NEW<br />

Available May 2013<br />

accessories<br />

<strong>for</strong> insulated and metal consumer units<br />

RX 3 residential MCBs and<br />

single module RCBOs p. 10<br />

6065 62<br />

Dimensions p. 12<br />

Con<strong>for</strong>m to BS EN 60439-3. IP 30. RAL 9003 - white colour<br />

Pre-galvanised steel <strong>for</strong> strength and rigidity<br />

Door opens downwards<br />

Supplied with neutral and earth terminals completely assembled<br />

Supplied with 5 module spare blank plate<br />

MCBs to be ordered separately, (see p. 10)<br />

Pack<br />

Cat. Nos. Metal dual RCD split load - surface mounting<br />

16 module unit (10 ways available)<br />

1 6065 57 With 100 A main switch and 2 x 80 A 30 mA RCD<br />

22 module unit (16 ways available)<br />

1 6065 58 With 100 A main switch and 2 x 80 A 30 mA RCD<br />

Metal with incomer - surface mounting<br />

Epoxy/polyester powder coated base and lid<br />

Stand-off feet complete with keyhole fixing<br />

8 module unit<br />

1 6065 59 With 100 A main switch (6 ways available)<br />

12 module unit<br />

1 6065 60 With 100 A main switch (10 ways available)<br />

Metal custom build - surface mounting<br />

Epoxy/polyester powder coated base and lid<br />

Stand-off feet complete with keyhole fixing<br />

Allow several configurations when using kits and<br />

incomers (isolating switches, RCDs, RCBOs)<br />

For kits, (see opposite)<br />

For incomers and outgoing devices, (see p. 10)<br />

1 6065 61 8 modules available<br />

1 6065 62 12 modules available<br />

1 6065 50 16 modules available<br />

1 6065 51 22 modules available<br />

Pack<br />

Cat. Nos. Accessories<br />

Incomer or dual tariff kit<br />

1 6075 19 Comprises : 1 flexible neutral (blue) lead<br />

1 rigid neutral link<br />

Split load kit<br />

1 6075 39 Comprises : 1 flexible live (brown) lead<br />

1 flexible neutral (blue) lead<br />

2 rigid neutral links<br />

Split load dual tariff kit (<strong>for</strong> insulated units only)<br />

1 6075 49 Comprises : 1 flexible live (brown) lead<br />

2 flexible neutral (blue) leads<br />

2 rigid neutral links<br />

1 neutral terminal<br />

NEW<br />

Spare blank plate RAL 9003<br />

20 0016 60 5 modules - white colour<br />

Spare blank plate RAL 9010<br />

10 0016 64 18 module, separable by single or half modules<br />

Spare busbar<br />

5 6075 99 21 prongs<br />

NEW<br />

Spacing elements<br />

10 4063 07 0·5 module<br />

Locking device <strong>for</strong> MCBs and RCDs<br />

2 4063 03 Locking attachment <strong>for</strong> Ø 4 mm and<br />

Ø 6 mm padlocks<br />

NEW<br />

Padlock <strong>for</strong> MCBs and RCDs<br />

3 4063 13 Padlock Ø 4 m<br />

Spare terminal block<br />

1 8204 07 13 hole<br />

Self-adhesive label holder<br />

10 0049 96 Width : 16 mm<br />

Width available <strong>for</strong> marking : 12 mm<br />

Length 530 mm (24 modules)<br />

0049 96<br />

9


protection and control devices<br />

4022 70<br />

6064 18<br />

4020 27 4064 55<br />

4125 44 4130 91<br />

Pack Cat. Nos. RX 3 residential MCBs - 6 kA<br />

Breaking capacity : 6 kA to BS EN 60898-1<br />

Single pole - 230/400 V±<br />

B curve C curve Nominal rating Number of<br />

(In)<br />

17·5 mm modules<br />

10 4022 70 4023 10 6 A 1<br />

10 4022 71 4023 11 10 A 1<br />

10 4022 72 4023 13 16 A 1<br />

10 4022 73 4023 14 20 A 1<br />

10 4022 74 4023 15 25 A 1<br />

10 4022 75 4023 16 32 A 1<br />

10 4022 76 4023 17 40 A 1<br />

10 4022 77 4023 18 50 A 1<br />

10 4022 78 4023 19 63 A 1<br />

DX 3 multi-purpose MCBs - 10 kA<br />

Breaking capacity : 10 kA to BS EN 60947-2<br />

Single pole - 230/400 V±<br />

B C B curve C curve Nominal rating Number of<br />

(In)<br />

17·5 mm modules<br />

1 1 4074 29 4076 66 6 A 1<br />

1 10 4074 30 4076 68 10 A 1<br />

1 10 4074 32 4076 70 16 A 1<br />

1 1 4074 33 4076 71 20 A 1<br />

1 1 4074 35 4076 73 32 A 1<br />

1 1 4074 36 4076 74 40 A 1<br />

1 1 4074 37 4076 75 50 A 1<br />

1 1 4074 38 4076 76 63 A 1<br />

NEW<br />

RCBOs (combined MCB/RCD) -<br />

Single module<br />

Breaking capacity : 10 kA to BS EN 61009-1<br />

RCD type AC con<strong>for</strong>m to BS EN 61009-1<br />

Terminal capacity : rigid conductor 35 mm 2<br />

flexible conductor 25 mm 2<br />

Single pole and neutral - 240 V±<br />

B curve Nominal rating Number of<br />

(In)<br />

17·5 mm modules<br />

30 mA<br />

1 6064 16 6 A 1<br />

1 6064 17 10 A 1<br />

1 6064 18 16 A 1<br />

1 6064 19 20 A 1<br />

1 6064 20 32 A 1<br />

1 6064 21 40 A 1<br />

1 6064 28 50 A 1<br />

Pack<br />

Cat. Nos. RX 3 residual current devices (RCDs)<br />

Con<strong>for</strong>m to BS EN 61008-1<br />

Terminal capacity : rigid conductor 35 mm 2<br />

flexible conductor 25 mm 2<br />

Double pole 230 V±<br />

Type AC Nominal rating Number of<br />

(In)<br />

17·5 mm modules<br />

30 mA<br />

1 4020 24 25 A 2<br />

1 4020 25 40 A 2<br />

1 4020 26 63 A 2<br />

1 4020 27 80 A 2<br />

100 mA<br />

1 4020 28 25 A 2<br />

1 4020 29 40 A 2<br />

1 4020 30 63 A 2<br />

NEW<br />

DX 3 Isolating switches<br />

Con<strong>for</strong>m to BS EN 60947-3, IEC 60669-1<br />

Usage : AC 22 according to IEC 60947-3<br />

Red handle<br />

Double break contacts, padlockable<br />

50 mm 2 capacity shielded terminals<br />

Number of<br />

17·5 mm modules<br />

5 4064 53 63 A double pole 2<br />

5 4064 55 100 A double pole 2<br />

NEW<br />

NEW<br />

CX 3 Contactor with 230 V± coil<br />

Con<strong>for</strong>ms to BS EN 61095<br />

Double pole (L + N) 250 V±<br />

230 V± coil circuit Type of Number of<br />

I max. contact 17·5 mm<br />

modules<br />

230 V<br />

1 4125 44 25 A 2 N/O 1<br />

NEW<br />

For other contactors, see current Industrial and<br />

Power Protection catalogue<br />

Bell trans<strong>for</strong>mers<br />

d<br />

Con<strong>for</strong>m to IEC/EN 61558-2-8<br />

Supplied with label holder<br />

Protected against overloads and short circuits<br />

Power to 8 V-12 V or 24 V access control devices<br />

such as bells and chimes<br />

Possibility <strong>for</strong> supply busbars to run through<br />

(Cat. Nos. 4130 90/91)<br />

Number<br />

Secondary (V) Rating (A) Power (VA) of 17·5 mm<br />

modules<br />

230 V / 8 V<br />

1 4130 90 8 V± 0·5 A 4 VA 2<br />

230 V / 12 V - 8 V<br />

1 4130 91 12/8 V± 0·66/1 A 8 VA 2<br />

230 V / 24 V - 12 V<br />

1 4130 93 24/12 V± 1/1·5 A 24/18 VA 4<br />

10


insulated consumer units<br />

surface mounting<br />

n Insulated - surface mounting dimensions (mm)<br />

A 110<br />

n 8 module unit<br />

Back box fixing centres and cable entries (mm)<br />

View from<br />

above<br />

2 cut-outs<br />

50 x 50<br />

2 cut-outs<br />

40 x 50<br />

50<br />

B<br />

195<br />

20<br />

40<br />

50<br />

6 cut-outs<br />

20 x 25 8 cut-outs<br />

25 x 25<br />

View from<br />

sides<br />

2 cut-outs<br />

20 x 25<br />

Modules A (mm) B (mm)<br />

4 140 225<br />

225<br />

114<br />

162<br />

8 212 225<br />

12 298 225<br />

14/16 370 225<br />

20/22 478 225<br />

6 cut-outs 20 x 25<br />

n 4 module unit<br />

Back box fixing centres and cable entries (mm)<br />

View from<br />

below<br />

View from<br />

above<br />

1 cut-out<br />

50 x 50<br />

1 cut-out<br />

40 x 50<br />

40<br />

20<br />

50<br />

n 12 module unit<br />

Back box fixing centres and cable entries (mm)<br />

4 cut-outs<br />

20 x 25<br />

4 cut-outs<br />

25 x 25<br />

View from<br />

sides<br />

View from<br />

above<br />

2 cut-outs<br />

50 x 50<br />

2 cut-outs<br />

40 x 50<br />

225<br />

114<br />

2 cut-outs<br />

20 x 25<br />

40<br />

20<br />

90<br />

225<br />

180<br />

6 cut-outs<br />

20 x 25<br />

2 cut-outs<br />

20 x 18 . 5<br />

22 cut-outs<br />

25 x 20<br />

50<br />

View from<br />

sides<br />

2 cut-outs<br />

20 x 25<br />

4 cut-outs 20 x 25<br />

268<br />

View from<br />

below<br />

2 cut-outs 20 x 25<br />

2 cut-outs 20 x 18 . 5<br />

View from<br />

below<br />

11


insulated consumer units<br />

surface mounting (continued)<br />

metal consumer units<br />

surface mounting<br />

n 14/16 module unit<br />

Back box fixing centres and cable entries (mm)<br />

View from<br />

above<br />

2 cut-outs 50 x 50 2 cut-outs 40 x 50<br />

n Metal - surface mounting dimensions (mm)<br />

A 113<br />

20<br />

40<br />

B<br />

50<br />

10 cut-outs 20 x 25<br />

30 cut-outs 25 x 20<br />

View from<br />

sides<br />

225<br />

180<br />

2 cut-outs<br />

20 x 25<br />

Modules A (mm) B (mm)<br />

8 219 235<br />

50<br />

200<br />

12 305 235<br />

340<br />

16 377 235<br />

22 485 235<br />

8 cut-outs 20 x 25<br />

n 8 module unit<br />

Back box fixing centres and cable entries (mm)<br />

View from<br />

below<br />

View from<br />

above<br />

4 cut-outs Ø 32<br />

n 20/22 module unit<br />

Back box fixing centres and cable entries (mm)<br />

100<br />

View from<br />

above<br />

2 cut-outs 50 x 50 2 cut-outs 40 x 50<br />

1 obround<br />

cut-out 100 x 50<br />

40<br />

20<br />

2 cut-outs 20 x 22 12 cut-outs 20 x 25<br />

50<br />

95 80<br />

4<br />

Ø 5<br />

42 cut-outs 25 x 20<br />

View from<br />

sides<br />

Ø 9<br />

3<br />

2 cut-outs<br />

20 x 25<br />

View from<br />

below<br />

225<br />

180<br />

1 cut-out Ø 25<br />

448<br />

2 cut-outs 20 x 22<br />

10 cut-outs 20 x 25<br />

View from<br />

below<br />

12


metal consumer units<br />

surface mounting (continued)<br />

n 12 module unit<br />

Back box fixing centres and cable entries (mm)<br />

4 cut-outs Ø 32<br />

n 22 module unit<br />

Back box fixing centres and cable entries (mm)<br />

4 cut-outs Ø 25<br />

View from<br />

above<br />

View from<br />

above<br />

175<br />

350<br />

120<br />

95 80<br />

1 obround<br />

cut-out 100 x 50<br />

95 80<br />

2 obround<br />

cut-outs 100 x 50<br />

100<br />

View from<br />

below<br />

275<br />

8 cut-outs Ø 20<br />

4 cut-outs Ø 32<br />

n 16 module unit<br />

Back box fixing centres and cable entries (mm)<br />

4 cut-outs Ø 20<br />

250<br />

120<br />

2 obround<br />

cut-outs 100 x 50<br />

95 80<br />

2 cut-outs Ø 20<br />

2 cut-outs Ø 25<br />

View from<br />

below<br />

View from<br />

above<br />

175<br />

View from<br />

below<br />

4 cut-outs Ø 25<br />

4 cut-outs Ø 32<br />

13


Contact details<br />

United Kingdom<br />

Great King Street North,<br />

Birmingham, B19 2LF<br />

Customer Services:<br />

Tel: +44 (0) 845 605 4333 Fax: +44 (0) 845 605 4334<br />

E-mail: legrand.sales@legrand.co.uk<br />

Quotations and Technical Support:<br />

Tel: +44 (0) 870 608 9020 Fax: +44 (0) 870 608 9021<br />

E-mail: uk-wdsales@legrand.co.uk<br />

Republic of Ireland:<br />

Tel: 01 295 9673 Fax: 01 295 4671<br />

E-mail: legrand.sales@legrand.co.uk<br />

Distributor:<br />

Head ofice (UK and Ireland):<br />

<strong>Legrand</strong> Electric Limited<br />

Great King Street North, Birmingham, B19 2LF<br />

Tel: 0870 608 9000 Fax: 0870 608 9004<br />

Website: www.legrand.co.uk<br />

Consumer unit product guide 04/2013.PDF<br />

This document is printed on sustainably sourced paper. Please recycle.<br />

The <strong>Legrand</strong> logo is a registered trademark<br />

of the <strong>Legrand</strong> group of companies.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!