<strong>COOLING</strong> <strong>PIPING</strong> <strong>PLANS</strong><br />

Many pumps in high temperature services require cooling water piping to the<br />

bearing housing or stuffing box jacket. Using API610 (5 th Ed.) as a basis of<br />

description, the following lists the optional standard plans that are available from<br />

Dean Pump. These plans are offered in steel and stainless steel and are offered in<br />

tubing or in piping to meet customer requirements. If a specific requirement is not<br />

shown, please contact the factory for assistance.<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 1


<strong>COOLING</strong> PLAN PER DEAN PUMP SK1191<br />

PARTIAL <strong>COOLING</strong> TO BEARING HOUSING<br />

Many customers furnish their own cooling piping plans for pumps in hot services. The connection from the<br />

stuffing box/ seal chamber cooling jacket to the inlet side of the bearing cooling coil is difficult for an<br />

inexperienced person because of the number of bends that must be made. Dean Plan SK1191 is the<br />

difficult piping that customers prefer not to do.<br />

SK1191<br />

Partial Cooling to<br />

Bearing Housing<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$210 N/A $334 N/A<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 2


<strong>COOLING</strong> PLAN A – <strong>COOLING</strong> TO BEARING HOUSING<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

List Prices<br />

PLAN A<br />

Cooling to Bearing Housing<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

N/A $997 N/A $2,243<br />

Cooling Plan Optional Features<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

Consult Factory<br />

NOTES:<br />

1. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 3


<strong>COOLING</strong> PLAN B – <strong>COOLING</strong> TO BEARING HOUSING<br />

WITH PARALLEL GLAND QUENCH FLOW TO SEAL PLATE<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

PLAN B<br />

Cooling to Bearing Housing<br />

with Parallel Gland Quench<br />

Flow to Seal Plate<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$1,566 $1,203 $2,782 $3,011<br />

Cooling Plan Optional Features<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

Consult Factory<br />

NOTES:<br />

1. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 4


<strong>COOLING</strong> PLAN C – <strong>COOLING</strong> TO STUFFING BOX/<br />

SEAL CHAMBER JACKET<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

PLAN C<br />

Cooling to Stuffing Box/<br />

Seal Chamber Jacket<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$554 $986 $1,179 $2,180<br />

Cooling Plan Optional Features<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

Consult Factory<br />

NOTES:<br />

1. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 5


<strong>COOLING</strong> PLAN D – <strong>COOLING</strong> TO STUFFING BOX/SEAL<br />

CHAMBER JACKET WITH PARALLEL FLOW TO GLAND QUENCH<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

PLAN D<br />

Cooling to Stuffing Box/Seal<br />

Chamber Jacket with<br />

Parallel Flow to Gland Quench<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$1,076 $1,191 $2,578 $2,941<br />

Cooling Plan Optional Features<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

Consult Factory<br />

NOTES:<br />

1. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 6


<strong>COOLING</strong> PLAN E – <strong>COOLING</strong> TO STUFFING BOX/SEAL<br />

CHAMBER JACKET AND BEARING HOUSING IN SERIES<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

PLAN E<br />

Cooling to Stuffing Box/Seal<br />

Chamber Jacket and<br />

Bearing Housing in Series<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$787 $1,179 $1,591 $2,795<br />

Cooling Plan Optional Features<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

Consult Factory<br />

NOTES:<br />

1. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 7


<strong>COOLING</strong> PLAN F – <strong>COOLING</strong> TO STUFFING BOX/SEAL CHAMBER JACKET<br />

AND BEARING HOUSING IN SERIES WITH PARALLEL FLOW TO GLAND QUENCH<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

PLAN F<br />

Cooling to Stuffing Box/Seal<br />

Chamber Jacket and Bearing<br />

Housing in Series with Parallel<br />

Flow to Gland Quench<br />

Cooling Plan Optional Features<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$1,173 $1,431 $2,760 $3,078<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

Consult Factory<br />

NOTES:<br />

1. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 8


<strong>COOLING</strong> PLAN G – <strong>COOLING</strong> TO PEDESTALS, STUFFING BOX/<br />

SEAL CHAMBER JACKET, AND BEARING HOUSING IN SERIES<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

PLAN G<br />

Cooling to Pedestals, Stuffing<br />

Box/Seal Chamber Jacket, and<br />

Bearing Housing in Series<br />

(See Note 1)<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$2,188 $2,467 $2,905 $5,362<br />

Cooling Plan Optional Features<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

Consult Factory<br />

NOTES:<br />

1. <strong>Water</strong> cooled pedestal, where required, are priced separately in the pump pricing section and are not included in the cooling<br />

piping pricing.<br />

2. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 9


<strong>COOLING</strong> PLAN H – <strong>COOLING</strong> TO PEDESTALS, STUFFING BOX/SEAL CHAMBER JACKET,<br />

AND BEARING HOUSING IN SERIES WITH PARALLEL FLOW TO GLAND QUENCH<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

PLAN H<br />

Cooling to Pedestals, Stuffing<br />

Box/Seal Chamber Jacket, and<br />

Bearing Housing in Series<br />

with Parallel Flow to Gland Quench<br />

(See Note 1)<br />

Cooling Plan Optional Features<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$2,378 $2,674 $3,914 $5,699<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

NOTES:<br />

1. <strong>Water</strong> cooled pedestal, where required, are priced separately in the pump pricing section and are not included in the cooling<br />

piping pricing.<br />

2. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Consult Factory<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 10


<strong>COOLING</strong> PLAN J – <strong>COOLING</strong> TO STUFFING BOX/SEAL CHAMBER<br />

JACKET WITH PARALLEL FLOW TO HEAT EXCHANGER<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

PLAN J<br />

Cooling to Stuffing Box/Seal<br />

Chamber Jacket with<br />

Parallel Flow to Heat Exchanger<br />

(See Note 1)<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$2,706 $2,870 $6,345 $6,351<br />

Cooling Plan Optional Features<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

Consult Factory<br />

NOTES:<br />

1. The heat exchanger is not included in the cooling piping pricing. The cooling system does require a heat exchanger which is<br />

provided with the seal flush piping. Review your offering carefully.<br />

2. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 11


<strong>COOLING</strong> PLAN K – <strong>COOLING</strong> TO STUFFING BOX/SEAL CHAMBER JACKET AND<br />

BEARING HOUSING IN SERIES WITH PARALLEL FLOW TO HEAT EXCHANGER<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

PLAN K<br />

Cooling to Stuffing Box/Seal<br />

Chamber Jacket and Bearing<br />

Housing in Series with Parallel<br />

Flow to Heat Exchanger<br />

(See Note 1)<br />

Cooling Plan Optional Features<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$2,970 $3,091 $6,787 $6,985<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

NOTES:<br />

1. The heat exchanger is not included in the cooling piping pricing. The cooling system does require a heat exchanger which is<br />

provided with the seal flush piping. Review your offering carefully.<br />

2. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Consult Factory<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 12


<strong>COOLING</strong> PLAN L – <strong>COOLING</strong> TO PEDESTALS, STUFFING BOX/SEAL CHAMBER JACKET,<br />

AND BEARING HOUSING IN SERIES WITH PARALLEL FLOW TO HEAT EXCHANGER<br />

Note: An Asterisk (*) Indicates an Optional Item, Supplied at Additional Cost, When Specified by the Customer<br />

Cooling water piping plans are designed to route cooling water to one or more pump features from the user<br />

cooling water system and return the flow to the system. All systems are furnished with either tubing or<br />

piping with a choice of carbon or stainless steel materials. All cooling systems are limited to a maximum<br />

working pressure of 125psi. All components are Dean choice and all plans are factory installed. Customers<br />

who wish to install their own cooling plans may wish to have a partial cooling plan (Reference Dean<br />

SK1191) installed by the factory. See SK1191.<br />

PLAN L<br />

Cooling to Pedestals, Stuffing<br />

Box/Seal Chamber Jacket, and<br />

Bearing Housing in Series with<br />

Parallel Flow to Heat Exchanger<br />

(See Notes 1 & 2)<br />

Cooling Plan Optional Features<br />

List Prices<br />

Steel Tubing Steel Piping Stainless Tubing Stainless Piping<br />

$3,305 $3,481 $7378 $7,702<br />

Exit Side Valve (Each) $369 $377 $ 884 $ 884<br />

Exit Side Flow Indicator (Each) $382 $317 $1,050 $1,050<br />

Thermal Relief Valve<br />

Consult Factory<br />

NOTES:<br />

1. The heat exchanger is not included in the cooling piping pricing. The cooling system does require a heat exchanger which is provided with the<br />

seal flush piping. Review your offering carefully.<br />

2. <strong>Water</strong> cooled pedestals, where required, are priced separately in the pump pricing section and are not included in the cooling piping pricing.<br />

3. Stainless tubing, piping, and fittings will be 316SS construction.<br />

Effective: FEBRUARY 2011 • Replaces: NEW<br />

Page 13