DAKO Autostainer Universal Staining System
DAKO Autostainer Universal Staining System
DAKO Autostainer Universal Staining System
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
CIHRT Exhibit P-2339 Page 1<br />
For further information pleaseffice'<br />
contact your nearest <strong>DAKO</strong> 0 .<br />
Australia<br />
Tel. 2 9316 4633<br />
Fax 2 93164773<br />
Austria<br />
Tel. 0800 0800 7153<br />
Fax 0800 0800 7154<br />
Belgium<br />
Tel. 0163872 20<br />
Fax 016 38 72 21<br />
<strong>DAKO</strong> <strong>Autostainer</strong><br />
<strong>Universal</strong> <strong>Staining</strong><br />
<strong>System</strong><br />
Canada<br />
Tel. 905 858 8510<br />
Fax 905 858 8801<br />
Czech Republic<br />
Tel. 05-41423710<br />
Fax 05-41 423711<br />
Denmark<br />
Tel. 44 85 95 00<br />
Fax 44 85 95 95<br />
France<br />
Tel. 1 30 50 00 50<br />
Fax 1 30 50 00 11<br />
Germany<br />
Tel. 04069 69 470<br />
Fax 040 69 52 741<br />
Italy<br />
Tel. 02 58 078 231<br />
Fax 02 58 078 292<br />
Japan<br />
Tel. 075 211 3655<br />
Fax 075 211 1755<br />
The Netherlands<br />
Tel. 0204211100<br />
Fax 020 42 11 101<br />
Norway<br />
Tel. 23 14 05 40<br />
Fax 23 14 05 42<br />
Poland<br />
Tel. 058-661 1879<br />
Fax 058-661 3390<br />
Spain<br />
Tel. 93 499 05 06<br />
Fax 93 499 02 08<br />
Sweden<br />
Tel. 08 556 20 600<br />
Fax 08 556 20 619<br />
Switzerland<br />
Tel. 041 76011 66<br />
Fax 041 76011 77<br />
United Kingdom<br />
Tel. (0)1 353 66 99 11<br />
Fax (0)1 353 66 89 89<br />
United States of<br />
America<br />
Tel. 805 566 6655<br />
Fax 805 566 6688<br />
International Web site<br />
www.dako.com<br />
Distributors in .<br />
more than 40 countnes<br />
OAKoautostainer<br />
• Instrument<br />
• Optimized reagents<br />
• User-friendly software<br />
• Technical support<br />
• Research and development<br />
• Quality assurance<br />
• Superior staining quality
CIHRT Exhibit P-2339 Page 2<br />
~I<br />
AKO<br />
<strong>DAKO</strong> - The Total Solution<br />
in Automated Immunohistochemistry<br />
More than Just an Instrument<br />
Mammary carcinoma<br />
stained with Anti<br />
Progesterone Receptor,<br />
code No. N 1630, using the<br />
<strong>DAKO</strong> LSAS"2 <strong>System</strong>.<br />
The modern pathology laboratory is faced<br />
with increasing demands on productivity,<br />
cost-efficiency as well as quality and<br />
consistency of results.<br />
The answer to this challenge is automation<br />
- provided as a total solution.<br />
Mammary carcinoma<br />
stained with Anti-Estrogen<br />
Receptor a, code No.<br />
N 1575, using the<br />
<strong>DAKO</strong> LSAso2 <strong>System</strong>.<br />
Up to 48<br />
slides can<br />
be individually<br />
programmed and<br />
processed in a<br />
given run.<br />
<strong>DAKO</strong> has a 30-year track record as the leader<br />
in immunohistochemistry. The combination of<br />
reagent and instrument supply enables <strong>DAKO</strong><br />
to offer solutions for today's laboratory<br />
demands.<br />
The <strong>DAKO</strong> <strong>Autostainer</strong> is a proven and<br />
validated system within the <strong>DAKO</strong><br />
organization, backed by optimized reagents,<br />
skilled support and qualified service engineers.<br />
When you choose <strong>DAKO</strong> as an instrument<br />
and reagent supplier, you acquire more than<br />
just performance.<br />
• Technical partnership<br />
<strong>DAKO</strong> provides reference material,<br />
dedicated technical application<br />
support and user training.<br />
• Instrument support<br />
<strong>DAKO</strong> offers multiple options of service<br />
agreements to fit your specific needs.<br />
You will always be served by a local<br />
service engineer who understands<br />
your situation.<br />
• Reagent reliability<br />
Our long experience in the field of<br />
immunohistochemistry offers you the<br />
best guarantee of reliable and validated<br />
products. <strong>DAKO</strong> develops products based<br />
on input from you and your colleagues<br />
around the world.<br />
• Financial partnership<br />
It is a well-known fact that automation<br />
brings cost-benefits. At <strong>DAKO</strong> we are<br />
prepared to offer you customized<br />
solutions that consider your workload,<br />
inventory supply, and need for service<br />
and support.<br />
Access up to<br />
64 different reagents<br />
by using both<br />
racks; program<br />
complex protocols<br />
and/or mUltiple<br />
protocols<br />
simultaneously.<br />
Hodgkin's lymphoma<br />
stained with Anti-CD30,<br />
code No. N 1558, using the<br />
<strong>DAKO</strong> EnVision <strong>System</strong>.<br />
Mammary carcinoma<br />
stained with Anti-Cytokeratin,<br />
code No. N 1523, using the<br />
<strong>DAKO</strong> EnVision <strong>System</strong>.<br />
Tonsil stained with Anti-SCL2<br />
Oncoprotein, code No.<br />
M 0887, using the <strong>DAKO</strong><br />
CSA <strong>System</strong>.<br />
Tonsil stained with Anti<br />
CD23, code No. M 0763,<br />
using the <strong>DAKO</strong><br />
CSA <strong>System</strong><br />
Teflono-coated precisJon tip<br />
provides dependabl results without<br />
the need for freque t replacements<br />
M OAKO<br />
It<br />
or<br />
is<br />
the<br />
specially<br />
nuisance<br />
design<br />
of d sposable:'~~_~==::::::::::,:~~~~~"'''IIIIIIIIII'!II!!II!==:~~:~<br />
d to minimize<br />
_<br />
protein adsorption anr carryover.<br />
~=~::::~~;2E§§§~~===~~~
CIHRT Exhibit P-2339 Page 3<br />
AKO<br />
<strong>DAKO</strong> <strong>Autostainer</strong> Reagents<br />
<strong>DAKO</strong> is acknowledged as the world leader<br />
in the development of antibodies and<br />
detection systems. <strong>DAKO</strong> has the largest<br />
panel of diagnostic antibodies and is the<br />
leading company within lymphoma and<br />
leukaemia immunophenotyping.<br />
ready-to-use antibodies, detection systems<br />
and accessories.<br />
All dedicated reagents are available in<br />
pre-filled <strong>Autostainer</strong> vials for convenience,<br />
ease of operation and time savings.<br />
Immunostaining <strong>System</strong>s<br />
Product<br />
Code No.<br />
<strong>Universal</strong> LSAB2 Kit/HRP, Rabbit/Mouse K 0675<br />
<strong>Universal</strong> LSAB+ KitlHRP. Rabbit/Mouse/Goat K0690<br />
Link (10 x 11 mL)<br />
Streptavidin Peroxidase (10 x 11 mL)<br />
Accessory Products<br />
Product<br />
Hematoxylin (500 mL)<br />
Peroxidase-Blocking Reagent (10 x 11 mL)<br />
Protein Block, Serum Free (10 x 11 mL)<br />
Proteinase K, Prediluted (10 x 11 mL)<br />
<strong>Universal</strong> Negative Control, Ready-to-Use.<br />
Code No.<br />
S 3301<br />
S 2001<br />
X 0909<br />
S 3020<br />
N 1698<br />
We have developed a comprehensive range of<br />
dedicated reagents for the <strong>DAKO</strong> <strong>Autostainer</strong>.<br />
The reagents include a wide range of<br />
We provide empty vials and a range of<br />
optimized protocols for ready-to-use<br />
reagents that are not yet available in<br />
pre-filled vials.<br />
Substrate Chromogens<br />
Product<br />
Code No.<br />
<strong>DAKO</strong> AEC Substrate-Chromogen, Ready-To-Use K 3464<br />
<strong>DAKO</strong> AEC+ SUbstrate-Chromogen, Ready-Te-Use K 3469<br />
<strong>DAKO</strong> Liquid DAB K 3466<br />
for N-Series Mouse Primary Antibodies<br />
<strong>Universal</strong> Negative Control, Ready-to-Use,<br />
for N-Series Rabbit Primary Antibodies<br />
Wash Buffer, Concentrated x 10 (1 L)<br />
N 1699<br />
S3006<br />
<strong>DAKO</strong> Liquid DAB+ K 3468<br />
(10 x 11 mL)<br />
Products Packaged for the <strong>DAKO</strong> <strong>Autostainer</strong><br />
Ready-to-use Antibodies·<br />
Product<br />
Rb a Hu Alpha-1-Fetoprotein<br />
Mo a Hu BCL2 Oncoprotein, Clone 124<br />
Mo a Hu Carcinoembryonic Antigen, Clone 11-7<br />
Rba Hu Carcinoembryonic Antigen<br />
Rba Hu CD3, TCeli<br />
Moa Hu CD20cy, B Cell, Clone L26<br />
Moa Hu CD30, Ki-1 Antigen, Clone Ber-H2<br />
Moa Hu CD45RO, T Cell, Clone UCHL-1<br />
Rb a Hu Chromogranin A<br />
Mo a Hu Cytokeratin, Clone AE1/AE3<br />
Mo a Hu Cytokeratin. Clone MNF116<br />
Moa Hu Cytokeratin. High Molecular Weight, Clone 34~E12<br />
Moa Hu Cytokeratin 8, Low Molecular Weight, Clone 35~H11<br />
Moa Hu Desmin, Clone 033<br />
Moa Hu Epithelial Membrane Antigen, Clone E29<br />
Moa Hu Estrogen Receptor fl., Clone 105<br />
Rb aCw Glial Fibrillary Acidic Protein<br />
Rb a Hu Kappa Light Chains<br />
RbaCw Keratin, Wide Spectrum Screening<br />
Mo a Hu Ki-67 Antigen, Clone MIB-1<br />
Rba Hu Ki-67 Antigen<br />
Rb a Hu Lambda Light Chains<br />
Moa Hu Leucocyte Common Antigen, Clones 2B11 + PD7/26<br />
Mo a Hu Melanosome, Clone HMB-45<br />
Mo a Hu Muscle Actin, Clone HHF35<br />
Mo a Hu Neuron-Specific Enolase. Clone BBS/NCNI-H14<br />
Rba Neuron-Specific Enolase<br />
Moa Hu p53 Protein, Clone 00-7<br />
Mo a Hu Progesterone Receptor, Clone 1A6<br />
Rb a Hu Prostate-Specific Antigen<br />
Code No.<br />
N 1501<br />
N 1587<br />
N 1586<br />
N 1503<br />
N 1580<br />
N 1502<br />
N 1558<br />
N 1520<br />
N 1535<br />
N 1590<br />
N 1523<br />
N 1553<br />
N 1560<br />
N 1526<br />
N 1504<br />
N 1575<br />
N 1506<br />
N 1510<br />
N 1512<br />
N 1633<br />
N 1574<br />
N 1513<br />
N 1514<br />
N 1545<br />
N 1567<br />
N 1557<br />
N 1516<br />
N 1581<br />
N 1595<br />
N 1517<br />
Products packaged<br />
for use on the<br />
<strong>DAKO</strong> <strong>Autostainer</strong><br />
offer great<br />
convenience.<br />
Detection <strong>System</strong>s of<br />
Several Performance Levels<br />
<strong>DAKO</strong> has a range of detection systems<br />
available for the <strong>DAKO</strong> <strong>Autostainer</strong>, covering<br />
a wide spectrum of routine and research<br />
applications.<br />
• LSAB2 is a routine detection system.<br />
For optimal convenience and fastest<br />
turn around time, ready-to-use primary<br />
antibodies are available.<br />
• EnVision detection systems are<br />
available as routine as well as high<br />
sensitivity (+) systems.<br />
• CSA" (Catalyzed Signal Amplification)<br />
is a powerful and unique detection<br />
system for "difficult" mouse and rabbit<br />
antibodies. It is up to 200 times more<br />
sensitive than conventional biotin methods.<br />
Slide-specific protocols including reagent<br />
volume and dispense patterns, thus<br />
optimizing reagent usage (here shown with<br />
multi-tissue sections<br />
on the<br />
slides).<br />
Rb a Hu<br />
RbaCw<br />
RbaCw<br />
Moa Hu<br />
Rba Hu<br />
Moa Hu<br />
Rb a Hu<br />
Prostatic Acid Phosphatase<br />
S100<br />
S100 A<br />
Smooth Muscle Actin. Clone 1A4<br />
Synaptophysin<br />
Vimentin, Clone V9<br />
Von Willebrand Factor<br />
N 1518<br />
N 1573<br />
N 1519<br />
N 1584<br />
N 1566<br />
N 1521<br />
N 1505<br />
• LSAB+ is a high sensitivity detection system.<br />
• EnVision* is based on a patented,<br />
labelled polymer technology. This biotin-free,<br />
two-step detection system eliminates<br />
• <strong>DAKO</strong> ARKTM (Animal Research Kit) is a<br />
sensitive system ideal for mouse monoclonal<br />
antibodies on mouse tissue without<br />
causing background staining.<br />
'Diluted antibody (2 x 11 mL) and negative control (11 mL)<br />
non-specific staining from endogenous<br />
biotin and provides more specific staining.<br />
* U.S. Patent 5,543.332 and European Patent 594,772.<br />
** The CSA <strong>System</strong> embodies technology developed<br />
by and licensed from NEN (U.S. Patent 5,196,306).
,~ ,~<br />
CIHRT Exhibit P-2339 Page 4<br />
~AKO<br />
Intelligent Automation and Software<br />
Flexible and fast programming of each run.<br />
The versatile <strong>DAKO</strong> <strong>Autostainer</strong> simplifies<br />
your workload and offers consistent staining<br />
results.<br />
The <strong>DAKO</strong> <strong>Autostainer</strong> software is flexible <br />
yet simple and intuitive, making it easy to set<br />
up a staining run. The laboratory technologist<br />
will soon be confident in operating the<br />
instrument, increasing the flexibility and<br />
reliability of your laboratory.<br />
customize a protocol for each individual<br />
slide. The option to adjust reagent volume<br />
and reagent dispense zone minimizes the<br />
reagent consumption without compromising<br />
staining quality.<br />
The system mimics manual staining, while<br />
improving lab-to-Iab and operator-to-operator<br />
consistency. To protect personnel and<br />
environment the system segregates hazardous<br />
from non-hazardous waste. There is a very<br />
Technical Specifications<br />
Dimensions<br />
Weight<br />
Electrical specifications<br />
Normal operating temperature<br />
Slide rack capacity<br />
Total slide capacity<br />
Reagent capacity<br />
Reagent dispense volumes<br />
Reagent probe volume capacity<br />
Fluid handling components<br />
Width 102 cm, Depth 69 cm, Height 61 cm<br />
63.5 kg<br />
220 V: 220/240 V (± 10%), 50 Hz (±2 Hz)<br />
(120 V: 110/120 V (± 10%), 60 Hz (±2 Hz))<br />
Ambient 18-26 "C<br />
1-12 slides<br />
1-48 slides<br />
64 different reagents (15 mUreagent vial)<br />
100, 150, 200, 400 and 600 ~L<br />
1.2 mL<br />
,)', High-precision, fixed stainless steel, Teflon~-coated reagent probe<br />
(designed to minimize protein adsorption), independent wash and blow elements<br />
f'<br />
"-<br />
Program Slides ""--"<br />
~=-<br />
.~<br />
=:<br />
.., _.<br />
~ ~<br />
..<br />
=<br />
~ ,~ ,,~<br />
~<br />
,7lOO<br />
~ ..::. ~<br />
,- ..~ ~ ~ i= i= ~<br />
I.-..<br />
_.<br />
w, ,. k,." 10.-, .1=<br />
"'"<br />
I- ....<br />
w, ,.<br />
-'D D D ,~ ~<br />
riItI600pl<br />
.Jl:11·1",ol.lid. Z1 Il,Jlwi,h400pl<br />
~~~:~:: ~~:;:~O~~J.IbH.H'S80<br />
U:lll-P"",plOGOpl<br />
:12:N·r"'ol.Iid.1I1l.2.Jlwi'h600pl<br />
l2:l'-T'Ul.'idcZ211.3)wilh400pl<br />
:~~:~~:';:::~~:::H:8l<br />
.H:U·Ri••••lldcl<br />
:H:15·Rln...,id.19<br />
J4:26-RIM••lld.8<br />
.J4:JI·RI lid.ZO<br />
).:••·w 1II00:42:20<br />
11:41 te:u:.<br />
Run log displaying current step and recording<br />
total run activity.<br />
The <strong>DAKO</strong> <strong>Autostainer</strong> <strong>Universal</strong> <strong>Staining</strong><br />
<strong>System</strong> is an automated horizontal slide<br />
processing system optimized with <strong>DAKO</strong><br />
reagents for the staining of formalin-fixed,<br />
paraffin-embedded tissues, frozen sections,<br />
cytospins, cell smears and fine needle<br />
aspirates. It consists of a slide processing<br />
unit, a desktop personal computer, software<br />
and a printer. The <strong>DAKO</strong> <strong>Autostainer</strong> is an<br />
open reagent system with an easy-to-use<br />
Windows 95/98 software that allows for<br />
pre-programmed and customized protocols.<br />
Instrument<br />
Product<br />
<strong>DAKO</strong> <strong>Autostainer</strong>, <strong>Universal</strong> <strong>Staining</strong> <strong>System</strong><br />
Accessory Products<br />
Product<br />
<strong>Autostainer</strong>, Drain Tube Kit<br />
<strong>Autostainer</strong>, Reagent Racks (2 Racks)<br />
<strong>Autostainer</strong>, Reagent Vials (100 Vials)<br />
<strong>Autostainer</strong>, Slide Clips (12 Clips)<br />
<strong>Autostainer</strong>, Slide Rack<br />
<strong>Autostainer</strong> Demonstration Pack<br />
DAB-Away, Cleaning Agent<br />
Clear-It Cleaning Reagent<br />
<strong>DAKO</strong> Seymour Glass Slide<br />
Labelling <strong>System</strong><br />
Product<br />
<strong>DAKO</strong> Seymour Glass Slide Labelling <strong>System</strong><br />
<strong>DAKO</strong> Seymour Label Kit<br />
Code No.<br />
S3400<br />
Code No.<br />
S 3423<br />
S 3424<br />
S 3425<br />
S 3422<br />
S 3396<br />
S 3410<br />
S 1967<br />
SL 002<br />
Code No.<br />
S 3416<br />
S 3417<br />
The <strong>DAKO</strong> <strong>Autostainer</strong><br />
Demonstration Pack<br />
includes a selection of<br />
two antibodies with<br />
matched positive<br />
control tissues,<br />
visualization<br />
system of choice and<br />
accessory reagents to<br />
demonstrate the<br />
performance and<br />
quality of results.<br />
The versatile <strong>DAKO</strong> <strong>Autostainer</strong> simplifies your workload as it enhances consistency<br />
• Walk-away convenience<br />
• Automated documentation<br />
• Mimics manual staining<br />
and avoids retraining<br />
• Easy set up and flexible programming<br />
• Consistent results and fewer repeats<br />
decrease costs<br />
• Enables inter and intralaboratory consistency<br />
• Allows simultaneous staining of multiple<br />
markers<br />
• Autoprogramming for convenient selection<br />
of protocols<br />
• <strong>DAKO</strong> Seymour Glass Slide Labelling<br />
<strong>System</strong> provides sample identification<br />
throughout slide processing