03.11.2014 Views

MODEL AV-1 - Tyco Fire Products

MODEL AV-1 - Tyco Fire Products

MODEL AV-1 - Tyco Fire Products

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MODEL</strong> <strong>AV</strong>-1<br />

Ordering Procedure<br />

Standard <strong>AV</strong>-1-300 Alarm Check Valve<br />

(American Standard Flange Drilling,<br />

American Threaded Ports, and American<br />

Groove Outside Diameter, as applicable):<br />

Specify: (specify size inch) Model <strong>AV</strong>-1-300<br />

Alarm Check Valve with (specify end connections),<br />

P/N (specify).<br />

2-1/2 Inch G x G<br />

2.88 inch (73,0 mm)<br />

Groove O.D. x 2.88<br />

inch (73,0 mm)<br />

Groove O.D. . . . . . . . .P/N 52-203-1-110<br />

2-1/2 Inch F x G<br />

ANSI Flange x<br />

2.88 inch (73,0 mm)<br />

Groove O.D. . . . . . . . .P/N 52-203-1-210<br />

4 Inch G x G<br />

4.50 inch (114,3 mm)<br />

Groove O.D. x 4.50<br />

inch (114,3 mm)<br />

Groove O.D. . . . . . . . .P/N 52-203-1-113<br />

4 Inch F x G<br />

ANSI Flange x<br />

4.50 inch (114,3 mm)<br />

Groove O.D. . . . . . . . .P/N 52-203-1-413<br />

4 Inch F x F<br />

ANSI Flange x<br />

ANSI Flange . . . . . . . .P/N 52-203-1-013<br />

6 Inch G x G<br />

6.62 inch (168,3 mm)<br />

Groove O.D. x 6.62<br />

inch (168,3 mm)<br />

Groove O.D . . . . . . . . .P/N 52-203-1-115<br />

6 Inch F x G<br />

ANSI Flange x<br />

6.62 inch (168,3 mm)<br />

Groove O.D . . . . . . . . .P/N 52-203-1-615<br />

6 Inch F x F<br />

ANSI Flange x<br />

ANSI Flange . . . . . . . .P/N 52-203-1-015<br />

8 Inch G x G<br />

8.62 inch (219,1 mm)<br />

Groove O.D x 8.62<br />

inch (219,1 mm)<br />

Groove O.D . . . . . . . . .P/N 52-203-1-916<br />

8 Inch F x G<br />

ANSI Flange x<br />

8.62 inch (219,1 mm)<br />

Groove O.D . . . . . . . . .P/N 52-203-1-816<br />

8 Inch F x F<br />

ANSI Flange x<br />

ANSI Flange . . . . . . . .P/N 52-203-1-016<br />

Standard Order <strong>AV</strong>-1-300 ValveTrim:<br />

Specify: Vertical, Closed Drain Galvanized<br />

Trim for (specify size)<br />

Model <strong>AV</strong>-1-300 Alarm Check Valve, P/N<br />

(specify).<br />

Vertical Closed Drain, Galvanized<br />

2-1/2 inch . . . . . . . . . . . . . .P/N 52-204-2-050<br />

4 or 6 inch . . . . . . . . . . . . . .P/N 52-204-2-951<br />

8 inch . . . . . . . . . . . . . . . . . .P/N 52-204-2-952<br />

1/2 INCH NPT<br />

CONNECTION<br />

FOR WATERFLOW<br />

PRESSURE ALARM<br />

SWITCH<br />

LOCATION<br />

FOR OPTIONAL<br />

ELECTRICALLY<br />

SUPERVISED<br />

N.O. ALARM<br />

CONTROL VALVE<br />

(BVS-3/4")<br />

<strong>MODEL</strong> RC-1<br />

RETARD<br />

CHAMBER<br />

ORDERED<br />

SEPARATELY<br />

(FOR VARIABLE<br />

PRESSURE<br />

SYSTEMS)<br />

RETARD<br />

CHAMBER<br />

RESTRICTION<br />

ASSEMBLY<br />

1/8"<br />

(3,2 mm)<br />

ORIFICE<br />

OUTLET<br />

WHEN FLOW THROUGH<br />

RESTRICTION ASSEMBLY<br />

INLET EXCEEDS OUTLET,<br />

RETARD CHAMBER<br />

BEGINS TO FILL<br />

WATERFLOW<br />

PRESSURE<br />

ALARM SWITCH<br />

Accessories<br />

Order the following accessories, as applicable:<br />

WATERFLOW<br />

TO WATER<br />

MOTOR ALARM<br />

7/32"<br />

(5,6 mm)<br />

ORIFICE<br />

INLET<br />

MAIN<br />

DRAIN<br />

VALVE<br />

Model RC-1<br />

Retard Chamber<br />

(required for variable pressure water supply<br />

conditions) . . . . . . . . .P/N 52-211-2-002<br />

Alarm Vent Trim<br />

(required when a water motor alarm is not<br />

installed) . . . . . . . . . . .P/N 52-201-2-012<br />

Model PS10-2A<br />

Potter Electric Waterflow Pressure Alarm<br />

Switch<br />

(required for electric signal indicating<br />

waterflow) . . . . . . . . .P/N 54-281-1-002<br />

Model WMA-1<br />

Water Motor Alarm (required for a mechanical<br />

waterflow alarm) . .P/N 52-630-1-001<br />

<strong>Tyco</strong> is a registered trademark of <strong>Tyco</strong> and/or its affiliates in the United States and/or other countries.<br />

All other brand names, product names, or trademarks belong to their respective holders.<br />

3<br />

LOCATION<br />

FOR OPTIONAL<br />

ELECTRICALLY<br />

SUPERVISED<br />

N.O. ALARM<br />

CONTROL VALVE<br />

(BVS-1/2")<br />

RESTRICTION<br />

ASSEMBLY,<br />

3/4 INCH NPT<br />

CONNECTION FOR<br />

WATER MOTOR<br />

ALARM<br />

1/2 INCH NPT<br />

CONNECTION<br />

FOR WATERFLOW<br />

PRESSURE ALARM<br />

SWITCH<br />

4<br />

ONCE RETARD<br />

CHAMBER OVERFLOWS,<br />

WATERFLOW PRESSURE<br />

ALARM SWITCH AND<br />

WATER MOTOR<br />

ALARM ACTUATE<br />

3/4 INCH NPT<br />

CONNECTION FOR<br />

WATER MOTOR<br />

ALARM<br />

WATERFLOW<br />

TO SYSTEM<br />

2<br />

WATERFLOW<br />

THROUGH SEAT<br />

RING GROOVE AND<br />

ALARM PORT<br />

OPERATION<br />

1<br />

UPON SPRINKLER<br />

FLOW, WATERWAY<br />

CLAPPER OPENS<br />

ALARM<br />

TEST VALVE<br />

(NORMALLY<br />

CLOSED)<br />

MAIN<br />

DRAIN VALVE<br />

(NORMALLY<br />

CLOSED)<br />

2 INCH NPT<br />

CONNECTION<br />

T DRAIN<br />

SYSTEM<br />

PRESSURE<br />

GAUGE<br />

SUPPLY<br />

PRESSURE<br />

GAUGE<br />

<strong>MODEL</strong> <strong>AV</strong>-1<br />

ALARM VALVE,<br />

6 INCH (DN150)<br />

FLANGE x FLANGE<br />

SHOWN<br />

SYSTEM<br />

PRESSURE<br />

GAUGE<br />

SUPPLY<br />

PRESSURE<br />

GAUGE<br />

VERTICAL CLOSED DRAIN TRIM - STANDARD ORDER - SEMI-PREASSEMBLED<br />

<strong>Tyco</strong> <strong>Fire</strong> <strong>Products</strong><br />

Technical Services<br />

Ph: 800-381-9312<br />

Fax: 800-791-5500<br />

www.<strong>Tyco</strong>-<strong>Fire</strong>.com<br />

<strong>Tyco</strong> <strong>Fire</strong> <strong>Products</strong> reserves the right to change product design and specifications 2<br />

without notice. Copyright © 2004 <strong>Tyco</strong> <strong>Fire</strong> <strong>Products</strong> LP. All rights reserved.<br />

Printed in USA /TFP-<strong>AV</strong>1/4M/CPI/09-04

Hooray! Your file is uploaded and ready to be published.