9.Greenbelt provided is inadequate. During the subsequent inspection conducted it is noticed<br />

that the company have taken positive steps for planting more trees and more trees and<br />

developing greenbelt .<br />

10. Effluent and water samples are collected for analysis.<br />

The report of analysis of the effluent collected from the authorized outlet of the factory<br />

on 20-11-04 and 15-7-05 are noted below.<br />

Parameters Analyzed<br />

Parameters Tolerance limits in the<br />

consent book<br />

1. PH 7.1 pH - 6.70 5.5-9.0<br />

2. BOD 0.9 mg/l<br />

3. COD 3.2 ,,<br />

4. SS 6.0 ,, SS - 9.0 100<br />

5. Zinc 0.04 ,, Zinc - 0.12 5<br />

6. Iron 0.11 ,,<br />

7. Lead 0.88 ,,<br />

8. Mercury ND<br />

9. Cadmium 0.07 ,,<br />

10. Copper 0.068 ,, copper - ND 3<br />

11. Nickel 0.03 ,, Nickel - ND 3<br />

12. Chlorides 34.0 ,,<br />

13. Cyanides ND ,,<br />

14. Phenolic compounds ND ,,<br />

15. Hexavalent Chromium ND ,, Hexavalent Chromium- 0.1 mg/l<br />

16. Total Chromium 0.03 ,, Total Chromium- 2mg/l<br />

17. Manganese 0.15 ,,<br />

18. Oil and grease ND ,, Oil and grease -10 mg/l<br />

19. Titanium ND ,,<br />

20. Free available Chlorine ND ,,<br />

The analysis report of the hazardous waste collected from the waste storage tank<br />

on 12-1-05 is given below. A/R no;1131 The report shows the presence of copper,<br />

Chromium compounds II exceeding the limits specified in class B schedule II and<br />

also high content of Zinc.<br />

Recommendation:<br />

1. A decision is to be taken by the Board on the company’s proposal to use the newly<br />

constructed hazardous waste storage tanks after providing required lining.<br />

2. Effluent treatment plant should be augmented for complete recycling of treated effluent.<br />

3.Chromium bearing effluent should be segregated and treated separately.<br />

4. Chromium recovery plant should be installed.<br />

5. Test wells are to be provided near the effluent treatment plant and hazardous waste<br />

storage tank.<br />

6. Greenbelt is to be improved.