9.Greenbelt provided is inadequate. During the subsequent inspection conducted it is noticed<br />
that the company have taken positive steps for planting more trees and more trees and<br />
developing greenbelt .<br />
10. Effluent and water samples are collected for analysis.<br />
The report of analysis of the effluent collected from the authorized outlet of the factory<br />
on 20-11-04 and 15-7-05 are noted below.<br />
Parameters Analyzed<br />
Parameters Tolerance limits in the<br />
consent book<br />
1. PH 7.1 pH - 6.70 5.5-9.0<br />
2. BOD 0.9 mg/l<br />
3. COD 3.2 ,,<br />
4. SS 6.0 ,, SS - 9.0 100<br />
5. Zinc 0.04 ,, Zinc - 0.12 5<br />
6. Iron 0.11 ,,<br />
7. Lead 0.88 ,,<br />
8. Mercury ND<br />
9. Cadmium 0.07 ,,<br />
10. Copper 0.068 ,, copper - ND 3<br />
11. Nickel 0.03 ,, Nickel - ND 3<br />
12. Chlorides 34.0 ,,<br />
13. Cyanides ND ,,<br />
14. Phenolic compounds ND ,,<br />
15. Hexavalent Chromium ND ,, Hexavalent Chromium- 0.1 mg/l<br />
16. Total Chromium 0.03 ,, Total Chromium- 2mg/l<br />
17. Manganese 0.15 ,,<br />
18. Oil and grease ND ,, Oil and grease -10 mg/l<br />
19. Titanium ND ,,<br />
20. Free available Chlorine ND ,,<br />
The analysis report of the hazardous waste collected from the waste storage tank<br />
on 12-1-05 is given below. A/R no;1131 The report shows the presence of copper,<br />
Chromium compounds II exceeding the limits specified in class B schedule II and<br />
also high content of Zinc.<br />
Recommendation:<br />
1. A decision is to be taken by the Board on the company’s proposal to use the newly<br />
constructed hazardous waste storage tanks after providing required lining.<br />
2. Effluent treatment plant should be augmented for complete recycling of treated effluent.<br />
3.Chromium bearing effluent should be segregated and treated separately.<br />
4. Chromium recovery plant should be installed.<br />
5. Test wells are to be provided near the effluent treatment plant and hazardous waste<br />
storage tank.<br />
6. Greenbelt is to be improved.