DIRECT ACTING<br />

PRESSURE REDUCING VALVE<br />

DPMS<br />

ENGINEERING<br />

Ref. No. P04479<br />

Release 09/2000<br />

1<br />

Description<br />

Direct <strong>acting</strong>, spool type <strong>pressure</strong> <strong>reducing</strong> <strong>valve</strong> with control<br />

<strong>of</strong> <strong>pressure</strong> from either secondary circuit (Model DPMS 06 SA)<br />

or from a remote source (Model DPMS 06 SB).<br />

Four <strong>pressure</strong> rating 25, 50, 100, 200 bar with primary <strong>pressure</strong><br />

rating to 315 bar.<br />

Optional check <strong>valve</strong> can be supplied as a stackable module.<br />

Pressure setting by screw adjustment.<br />

Section<br />

Hydraulic Symbol<br />

B<br />

P<br />

A<br />

P<br />

A<br />

T<br />

T<br />

Model<br />

DPMS 06 SA<br />

Model<br />

DPMS 06 SB<br />

Unit dimension<br />

Valve<br />

Ø5.5 thru, 4 nos.<br />

(Tightening torque 6 Nm)<br />

22 A/F<br />

Dimensions in mm.<br />

5 A/F<br />

25<br />

47<br />

178<br />

Pressure gauge port<br />

P<br />

44<br />

32.5<br />

B<br />

A<br />

31<br />

Ø 48<br />

T<br />

12<br />

8<br />

40.5<br />

60<br />

180<br />

<strong>Polyhydron</strong> Pvt. Ltd.<br />

78-80, Machhe Industrial Estate,<br />

Machhe, Belgaum - 590 014. INDIA.<br />

Phone : +91-(0)831-411001<br />

Fax : +91-(0)831-411002<br />

E-mail : polyhydron@vsnl.com<br />

Website : www.polyhydron.com<br />

P04479


DIRECT ACTING<br />

PRESSURE REDUCING VALVE<br />

DPMS<br />

ENGINEERING<br />

Ref. No. P04479<br />

2<br />

Subplate<br />

Ø4 drill, 5 deep.<br />

-16.25<br />

0<br />

32.5<br />

-16<br />

0<br />

7.5 10.3<br />

19<br />

27.8<br />

B<br />

P<br />

T<br />

40.5<br />

A<br />

M5 tap, 9 deep.<br />

4 nos.<br />

30<br />

7<br />

0.75<br />

5.85<br />

16.25<br />

26.65<br />

31.75<br />

Ø7<br />

0.8<br />

A<br />

40R<br />

90<br />

70<br />

L1<br />

P<br />

B<br />

10<br />

7.5<br />

B1<br />

65<br />

80<br />

T<br />

Ø 6.3 drill, 4 nos.<br />

Panel cut - out<br />

2.5<br />

G tap, T1 deep.<br />

ØD1 spotface, 1 mm deep.<br />

Subplate B1 Ø D1 G L1 T1<br />

1SD03G02 34 22 G1/4 36 12<br />

1SD03G03 44 25 G3/8 48 12<br />

Technical specification<br />

Construction .................................................... Direct <strong>acting</strong> spool type.<br />

Mounting .......................................................... Subplate mounting as per ISO 6403.<br />

Mounting position ............................................ Optional.<br />

Flow <strong>direct</strong>ion .................................................. From port P to A.<br />

Opearating <strong>pressure</strong> ........................................ For port P .............. 315 bar.<br />

For port A and B .... 200 bar.<br />

For port T .............. 60 bar max.<br />

Hydraulic medium ............................................ Mineral oil.<br />

Viscosity range ................................................ 10 cSt to 380 cSt.<br />

Fluid temperature range .................................. -20 °C to +70 °C.<br />

Fluid cleanliness requirement .......................... As per ISO 16/13.<br />

Maximum flow handling capacity ..................... Refer graph.<br />

Mass ................................................................ 1.54 kg.<br />

P04479


DIRECT ACTING<br />

PRESSURE REDUCING VALVE<br />

DPMS<br />

ENGINEERING<br />

Ref. No. P04479<br />

3<br />

Performance Curve<br />

Oil used : ISO VG 68, Viscosity : 68 cSt @ 40 °C, Temp. @ test : 52 - 55 °C.<br />

150<br />

125<br />

Pressure at port A<br />

100<br />

75<br />

50<br />

25<br />

0<br />

20 10 0 10 20 30<br />

A to T<br />

P to A<br />

Flow in l/min.<br />

Ordering code<br />

DPM S ,06 S A 50 ,03<br />

Direct <strong>acting</strong><br />

<strong>pressure</strong> <strong>reducing</strong> <strong>valve</strong>.<br />

Hand knob<br />

H<br />

Design code subject<br />

to change. Installation<br />

dimensions remain<br />

same for design code<br />

01 thru 09.<br />

Set screw<br />

S<br />

Adjustable <strong>pressure</strong> upto<br />

Size 06<br />

( ISO size 03 )<br />

25, 50, 100 or 200 bar<br />

Subplate mounting<br />

S<br />

A<br />

B<br />

Control at port A<br />

Control at port B<br />

Note : Subplate to be ordered separately.<br />

P04479


DIRECT ACTING<br />

PRESSURE REDUCING VALVE<br />

DPMS<br />

ENGINEERING<br />

Ref. No. P04479<br />

4<br />

All rights reserved.<br />

Subject to revision.<br />

P04479

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!