Baffling of Old CW No. 3 and Large CW No. 2<br />
Provided a True 30-MGD Approved Capacity<br />
– Baffling of old clearwell No. 3 increases effective<br />
volume factor (EVF) to 0.3 without a tracer study (i.e.,<br />
length-to-width [L:W] ratio = 10.5)<br />
– Baffling of large clearwell No. 2 increases EVF to 0.375<br />