05.11.2014 Views

Rosenberger SLink

Rosenberger SLink

Rosenberger SLink

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Rosenberger</strong><strong>SLink</strong><br />

Flexible Corrugated Cables 1/4" R<br />

Corrugated Cables 1/4" R<br />

Flexible Corrugated Cables 1/4" R<br />

xOrdering Number Remarks<br />

xSL 014R PE<br />

xSL 014R FRNC<br />

Standard polyethylene jacket<br />

Flame retardant, non- corrosive jacket<br />

xMechanical Data<br />

xInner conductor Copper clad alu wire 2.4 mm<br />

xDielectric Foamed PE 6.4 mm<br />

xDiameter over outer conductor Ring corrugated copper tube 7.5 mm<br />

xDiameter over outer jacket PE / FRNC 10.2 mm<br />

xUV resistant and halogen free<br />

PE / FRNC<br />

xCable weight PE 107 kg/km<br />

x FRNC 129 kg/km<br />

xTensile strength<br />

600 N<br />

xMin. bending radius, single<br />

50 mm<br />

xMin. bending radius, repeated<br />

120 mm<br />

xNumber of bends, minimum (typical) 15 (50)<br />

xBending moment<br />

2 Nm<br />

xFlat plate crush strength<br />

10 N/mm<br />

xRecommended hanger spacing<br />

0.6 m<br />

xPermissable temperature range, installation – 40 °C to + 60 °C<br />

xPermissable temperature range, operation – 55 °C to + 85 °C<br />

xElectrical Data<br />

xImpedance 50 ±1 Ω DC breakdown voltage 2200 V<br />

xRelative velocity of propagation 83 % Jacket spark, volts RMS 5000 V<br />

xCapacitance 80 pF/m Inner conductor DC- resistance 5.7 Ω/km<br />

xInductance 0.195 µH/m Outer conductor DC- resistance 3.5 Ω/km<br />

xMaximum operating frequency 15.8 GHz Insulation resistance ≥ 10 GΩ/km<br />

xCut off frequency 19.0 GHz Return loss 800 –1000 MHz 26 dB<br />

xPeak power rating 10.5 KW Return loss 1700 – 2500 MHz 24 dB<br />

Attenuation value and power rating<br />

xFrequency [MHz] 100 200 300 400 450 800 900 1000 1800 2000 2200 2500<br />

xAttenuation, typical [dB/100m] 4.22 6.02 7.45 8.64 9.15 12.6 13.4 14.2 19.4 20.7 21.7 23.3<br />

xMean power [kW] 1.79 1.25 1.00 0.85 0.82 0.58 0.55 0.52 0.38 0.35 0.34 0.31<br />

– Attenuation, ambient temperature: 20°C<br />

– Average power, ambient temperature: 40°C<br />

– Average power, inner conductor temperature: 100°C<br />

– Maximum attenuation value shall be 105% of the nominal attenuation value<br />

– Other frequencies on request<br />

10<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. +49- 86 84- 18- 0, Fax. +49- 86 84- 18- 499, www.rosenberger.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!