<strong>Rosenberger</strong><strong>SLink</strong><br />

Flexible Corrugated Cables 1 1/4" R<br />

Corrugated Cables 1 1/4" R<br />

Flexible Corrugated Cables 1 1/4" R<br />

xOrdering Number Remarks<br />

xSL 114R PE<br />

xSL 114R FRNC<br />

Standard polyethylene jacket<br />

Flame retardant, non- corrosive jacket<br />

xMechanical Data<br />

xInner conductor Copper tube 13.1 mm<br />

xDielectric Foamed PE 32.5 mm<br />

xDiameter over outer conductor Ring corrugated copper tube 35.8 mm<br />

xDiameter over outer jacket PE / FRNC 39.0 mm<br />

xUV resistant and halogen free<br />

PE / FRNC<br />

xCable weight PE 980 kg/km<br />

x FRNC 1117 kg/km<br />

xTensile strength<br />

2500 N<br />

xMin. bending radius, single<br />

200 mm<br />

xMin. bending radius, repeated<br />

380 mm<br />

xNumber of bends, minimum (typical) 15 (50)<br />

xBending moment<br />

50 Nm<br />

xFlat plate crush strength<br />

20 N/mm<br />

xRecommended hanger spacing<br />

1.2 m<br />

xPermissable temperature range, installation – 40 °C to + 60 °C<br />

xPermissable temperature range, operation – 55 °C to + 85 °C<br />

xElectrical Data<br />

xImpedance 50 ±1 Ω DC breakdown voltage 10000 V<br />

xRelative velocity of propagation 88 % Jacket spark, volts RMS 10000 V<br />

xCapacitance 76 pF/m Inner conductor DC- resistance 0.7 Ω/km<br />

xInductance 0.190 µH/m Outer conductor DC- resistance 0.54 Ω/km<br />

xMaximum operating frequency 3.3 GHz Insulation resistance ≥ 10 GΩ/km<br />

xCut off frequency 3.7 GHz Return loss 800 –1000 MHz 26 dB<br />

xPeak power rating 200 KW Return loss 1700 – 2500 MHz 24 dB<br />

Attenuation value and power rating<br />

xFrequency [MHz] 100 200 300 400 450 800 900 1000 1800 2000 2200 2500<br />

xAttenuation, typical [dB/100m] 0.82 1.19 1.55 1.81 1.92 2.66 2.85 3.03 4.27 4.48 4.75 5.14<br />

xMean power [kW] 12.9 8.81 6.37 5.69 5.40 3.90 3.70 3.50 2.40 2.30 2.20 2.03<br />

– Attenuation, ambient temperature: 20°C<br />

– Average power, ambient temperature: 40°C<br />

– Average power, inner conductor temperature: 100°C<br />

– Maximum attenuation value shall be 105% of the nominal attenuation value<br />

– Other frequencies on request<br />