Rosenberger SLink
Rosenberger SLink
Rosenberger SLink
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Rosenberger</strong><strong>SLink</strong><br />
Flexible Corrugated Cables 1 1/4" R<br />
Corrugated Cables 1 1/4" R<br />
Flexible Corrugated Cables 1 1/4" R<br />
xOrdering Number Remarks<br />
xSL 114R PE<br />
xSL 114R FRNC<br />
Standard polyethylene jacket<br />
Flame retardant, non- corrosive jacket<br />
xMechanical Data<br />
xInner conductor Copper tube 13.1 mm<br />
xDielectric Foamed PE 32.5 mm<br />
xDiameter over outer conductor Ring corrugated copper tube 35.8 mm<br />
xDiameter over outer jacket PE / FRNC 39.0 mm<br />
xUV resistant and halogen free<br />
PE / FRNC<br />
xCable weight PE 980 kg/km<br />
x FRNC 1117 kg/km<br />
xTensile strength<br />
2500 N<br />
xMin. bending radius, single<br />
200 mm<br />
xMin. bending radius, repeated<br />
380 mm<br />
xNumber of bends, minimum (typical) 15 (50)<br />
xBending moment<br />
50 Nm<br />
xFlat plate crush strength<br />
20 N/mm<br />
xRecommended hanger spacing<br />
1.2 m<br />
xPermissable temperature range, installation – 40 °C to + 60 °C<br />
xPermissable temperature range, operation – 55 °C to + 85 °C<br />
xElectrical Data<br />
xImpedance 50 ±1 Ω DC breakdown voltage 10000 V<br />
xRelative velocity of propagation 88 % Jacket spark, volts RMS 10000 V<br />
xCapacitance 76 pF/m Inner conductor DC- resistance 0.7 Ω/km<br />
xInductance 0.190 µH/m Outer conductor DC- resistance 0.54 Ω/km<br />
xMaximum operating frequency 3.3 GHz Insulation resistance ≥ 10 GΩ/km<br />
xCut off frequency 3.7 GHz Return loss 800 –1000 MHz 26 dB<br />
xPeak power rating 200 KW Return loss 1700 – 2500 MHz 24 dB<br />
Attenuation value and power rating<br />
xFrequency [MHz] 100 200 300 400 450 800 900 1000 1800 2000 2200 2500<br />
xAttenuation, typical [dB/100m] 0.82 1.19 1.55 1.81 1.92 2.66 2.85 3.03 4.27 4.48 4.75 5.14<br />
xMean power [kW] 12.9 8.81 6.37 5.69 5.40 3.90 3.70 3.50 2.40 2.30 2.20 2.03<br />
– Attenuation, ambient temperature: 20°C<br />
– Average power, ambient temperature: 40°C<br />
– Average power, inner conductor temperature: 100°C<br />
– Maximum attenuation value shall be 105% of the nominal attenuation value<br />
– Other frequencies on request<br />
14<br />
<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. +49- 86 84- 18- 0, Fax. +49- 86 84- 18- 499, www.rosenberger.com