Technical annex<br />
Electronic control units<br />
Compare 1–10 V Interface /DALI<br />
Wiring<br />
Adressibility<br />
of ECG<br />
<br />
Number ECG<br />
<br />
Dimming<br />
Dimming<br />
profile<br />
1-10 V DALI<br />
Two-core control line<br />
watch the polarity<br />
No<br />
Depends on installed dimmer<br />
resp. control unit<br />
Separate functions<br />
<br />
Tab. 2<br />
Two-core control line,<br />
protected against rev. polarity<br />
Push-Dim – dimming and switching via push button<br />
ching<br />
and dimming is via a conventional push button. The DALI dimmable<br />
electronic control units from <strong>BAG</strong> <strong>electronics</strong> with Push-Dim<br />
function can be alternatively wired for this purpose. Here the phase<br />
or neutral conductor for example is bridged with either of the two<br />
DALI connection terminals. The push button can now be connected<br />
between the other mains conductor and the second DALI connection<br />
terminal. Simultaneous use of the DALI interface and a push button<br />
is not permissible.<br />
Yes<br />
Depends on installed dimmer<br />
resp. control unit<br />
<br />
Combined functions<br />
Standardised<br />
logarithmic<br />
Standards IEC 60929 IEC 62386<br />
Service life of electronic control gears<br />
The service life and thus reliability of electronic control gear is determined<br />
by the failure rates of the components used.<br />
In addition to the electrical specification and quality of components,<br />
tronics<br />
ECGs from the ZITARES series are designed so that a failure<br />
rate of maximum 2% per 1,000 hours is expected with the maximum<br />
permissible housing temperature tc,max. This corresponds to a service<br />
life of 50,000 hours at a possible percentage of failed devices<br />
vice<br />
life of more than 20 years is achieved, whereby during this time<br />
period 10% of devices can statistically fail. With lower device temperatures<br />
the service life of the electronic control gear is increased.<br />
<br />
failure rate is approximately halved, corresponding to a service life<br />
of 100,000 hours. Exceeding the temperature tc,max can lead to a<br />
correspondingly drastic shortening of service life.<br />
To ensure the specified service life, all components and switching<br />
groups of <strong>BAG</strong> <strong>electronics</strong> ECGs are designed to operate below their<br />
permissible limit values. And in order to eliminate premature failures<br />
resulting from concealed defects, all devices pass through various<br />
test benches during the manufacturing process where component<br />
testing and measurements of operation-relevant data for example<br />
are implemented. The ECGs are then subjected to a final burn-in test<br />
before dispatch.<br />
Push button operation<br />
<strong>LED</strong> module OFF<br />
(Stand-by-mode)<br />
Tab. 3<br />
<strong>LED</strong> module ON<br />
(Lamp operation mode)<br />
Short press of<br />
button <br />
Long press of button<br />
> 0.5 s<br />
<strong>LED</strong> module on<br />
<br />
<br />
<strong>LED</strong> module ON and<br />
dimming<br />
<strong>LED</strong> module Off<br />
Dimming up resp. down<br />
Long press of button<br />
—<br />
Synchronisization mode<br />
<strong>LED</strong> module =<br />
100 % luminous flux<br />
60