Technical annex<br />

Electronic control units<br />

Compare 1–10 V Interface /DALI<br />

Wiring<br />

Adressibility<br />

of ECG<br />

<br />

Number ECG<br />

<br />

Dimming<br />

Dimming<br />

profile<br />

1-10 V DALI<br />

Two-core control line<br />

watch the polarity<br />

No<br />

Depends on installed dimmer<br />

resp. control unit<br />

Separate functions<br />

<br />

Tab. 2<br />

Two-core control line,<br />

protected against rev. polarity<br />

Push-Dim – dimming and switching via push button<br />

ching<br />

and dimming is via a conventional push button. The DALI dimmable<br />

electronic control units from <strong>BAG</strong> <strong>electronics</strong> with Push-Dim<br />

function can be alternatively wired for this purpose. Here the phase<br />

or neutral conductor for example is bridged with either of the two<br />

DALI connection terminals. The push button can now be connected<br />

between the other mains conductor and the second DALI connection<br />

terminal. Simultaneous use of the DALI interface and a push button<br />

is not permissible.<br />

Yes<br />

Depends on installed dimmer<br />

resp. control unit<br />

<br />

Combined functions<br />

Standardised<br />

logarithmic<br />

Standards IEC 60929 IEC 62386<br />

Service life of electronic control gears<br />

The service life and thus reliability of electronic control gear is determined<br />

by the failure rates of the components used.<br />

In addition to the electrical specification and quality of components,<br />

tronics<br />

ECGs from the ZITARES series are designed so that a failure<br />

rate of maximum 2% per 1,000 hours is expected with the maximum<br />

permissible housing temperature tc,max. This corresponds to a service<br />

life of 50,000 hours at a possible percentage of failed devices<br />

vice<br />

life of more than 20 years is achieved, whereby during this time<br />

period 10% of devices can statistically fail. With lower device temperatures<br />

the service life of the electronic control gear is increased.<br />

<br />

failure rate is approximately halved, corresponding to a service life<br />

of 100,000 hours. Exceeding the temperature tc,max can lead to a<br />

correspondingly drastic shortening of service life.<br />

To ensure the specified service life, all components and switching<br />

groups of <strong>BAG</strong> <strong>electronics</strong> ECGs are designed to operate below their<br />

permissible limit values. And in order to eliminate premature failures<br />

resulting from concealed defects, all devices pass through various<br />

test benches during the manufacturing process where component<br />

testing and measurements of operation-relevant data for example<br />

are implemented. The ECGs are then subjected to a final burn-in test<br />

before dispatch.<br />

Push button operation<br />

<strong>LED</strong> module OFF<br />

(Stand-by-mode)<br />

Tab. 3<br />

<strong>LED</strong> module ON<br />

(Lamp operation mode)<br />

Short press of<br />

button <br />

Long press of button<br />

> 0.5 s<br />

<strong>LED</strong> module on<br />

<br />

<br />

<strong>LED</strong> module ON and<br />

dimming<br />

<strong>LED</strong> module Off<br />

Dimming up resp. down<br />

Long press of button<br />

—<br />

Synchronisization mode<br />

<strong>LED</strong> module =<br />

100 % luminous flux<br />

60