The average power requirement for each measurement that produces one of these metrics,<br />

PMU<br />

<strong>Full</strong> Load<br />

Average Watts<br />

Reading<br />

% of Reading<br />

Uncertainty<br />

Watts<br />

Reading<br />

Correction<br />

Wattage<br />

Range<br />

Setting<br />

Power <strong>Full</strong> Load Energy<br />

% of Range<br />

Uncertainty<br />

Wattage<br />

Range<br />

Correction<br />

Total Wattage<br />

Correction<br />

Accuarcy<br />

Correction<br />

Factor<br />

<strong>Report</strong>ed<br />

Watt /<br />

Seconds<br />

Power MI<br />

Seconds: 163.4<br />

Adjusted Watt<br />

/<br />

Seconds<br />

Measurement<br />

<strong>Report</strong>ed<br />

Seconds<br />

Adjusted<br />

Average<br />

Watts<br />

DB Server PMU‐1 413.09 0.10% +0.41 1500 0.10% +1.50 +1.91 0.46% 67,746.0 68,059.7 163.4 416.5<br />

DB Server PMU‐2 0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 0.0<br />

DB Server PMU‐3 0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 0.0<br />

DB Server Total 413.09 67,746.0 68,059.7 163.4 416.5<br />

Storage PMU‐1 0 0.10% +0.00 0 0.10% +0.00 +0.00 0.00% - - 0.0<br />

Storage PMU‐2 0 0.10% +0.00 0 0.10% +0.00 +0.00 0.00% - - 0.0<br />

Storage PMU‐3 0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 0.0<br />

Storage PMU‐4 0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 0.0<br />

Storage Total 0 - - 158.1 0.0<br />

Monitor Name Plate 28 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% 4,575.2 4,575.2 163.4 28.0<br />

Misc PMU‐2 0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 0.0<br />

Misc PMU‐3 0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 0.0<br />

Misc Total 28 4,575.2 4,575.2 163.4 28.0<br />

REC Total 441.09 72,321.2 72,634.9 163.4 444.5<br />

PMU<br />

<strong>Full</strong> Load<br />

Average Watts<br />

Reading<br />

% of Reading<br />

Uncertainty<br />

Watts<br />

Reading<br />

Correction<br />

Throughput <strong>Full</strong> Load Energy<br />

Wattage<br />

Range<br />

Setting<br />

% of Range<br />

Uncertainty<br />

Wattage<br />

Range<br />

Correction<br />

Total Wattage<br />

Correction<br />

Accuarcy<br />

Correction<br />

Factor<br />

<strong>Report</strong>ed<br />

Watt /<br />

Seconds<br />

Throughput<br />

MI Seconds: 735.3<br />

Adjusted Watt<br />

/<br />

Seconds<br />

Measurement<br />

<strong>Report</strong>ed<br />

Seconds<br />

Adjusted<br />

Average<br />

Watts<br />

DB Server PMU‐1 437.0 0.10% +0.44 1500 0.10% +1.50 +1.94 0.44% 321,598.0 323,023.6 735.3 439.3<br />

DB Server PMU‐2 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 735.3 -<br />

DB Server PMU‐3 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 735.3 -<br />

DB Server Total 437.0 321,598.0 323,023.6 735.3 439.3<br />

Storage PMU‐1 0.0 0.10% +0.00 0 0.10% +0.00 +0.00 0.00% - - 735.3 -<br />

Storage PMU‐2 0.0 0.10% +0.00 0 0.10% +0.00 +0.00 0.00% - - 735.3 -<br />

Storage PMU‐3 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 735.3 -<br />

Storage PMU‐4 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 735.3 -<br />

Storage Total 0.0 - - 735.3 -<br />

Monitor Name Plate 28.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% 20,588.4 20,588.4 735.3 28.0<br />

Misc PMU‐2 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 735.3 -<br />

Misc PMU‐3 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 735.3 -<br />

Misc Total 28.0 20,588.4 20,588.4 735.3 28.0<br />

REC Total 464.95 342,186.4 343,612.0 719.5 477.6<br />

The TPC-Energy Primary Metric must be disclosed, including the calculation that is used to derive it.<br />

Power<br />

Watt-Secs<br />

Power<br />

MI Seconds<br />

Throughput<br />

MI Seconds<br />

<strong>Report</strong>ed<br />

QphH<br />

SUT Total Work<br />

163.4 735.3 71,438.3 17,834<br />

Throughput<br />

Watt-Secs<br />

<strong>Full</strong> Load Avg<br />

Watts<br />

REC Energy<br />

Consumption<br />

Watt-Secs<br />

REC Energy<br />

Consumption<br />

Watt-Hours<br />

Total REC 72,635 343,612 463.2 416,247 115.6<br />

DB Server 68,060 323,024 435.2 391,083 108.6<br />

Storage 0 0 0.0 0 0.0<br />

Misc. 4,575 20,588 28.0 25,164 7.0<br />

REC Energy<br />

Consumption<br />

}=======><br />

SUT Total Work<br />

X<br />

1000<br />

Watts / KQphH<br />

6.48<br />

Total REC Energy Consumption = 115.6 Watt-Hours<br />

SUT Total Work = 17834 queries<br />

115.6 Watt-Hours / 17834 queries = 0.00648 Watts / QphH@100GB<br />

0.00648 Watts / QphH@100GB * 1000 = 6.48 Watts / KQphH@100GB<br />

HP TPC-H FULL DISCLOSURE REPORT 95 July, 2010<br />