Secondary Metrics<br />

Additional Numerical Quanties<br />

<strong>Full</strong> Load<br />

Watts / KQphHAvg Watts<br />

<strong>Full</strong> Load<br />

% of REC<br />

Idle Avg.<br />

Watts<br />

Idle %<br />

of REC<br />

Database Server 21.93 435.2 94.0% 266.1 90.5%<br />

Storage 0.00 0.0 0.0% 0.0 0.0%<br />

Miscellaneous 1.41 28.0 6.0% 28.0 9.5%<br />

Total REC 6.48 463.2 100% 294.1 100%<br />

H.2.2. Secondary Metrics At <strong>Report</strong>ed Performance<br />

If the TPC-Energy Secondary Metrics are reported, the components of the REC that are included in each<br />

subsystem must be identified. This can be achieved with separate lists to be included in the FDR or with a specific<br />

designation in the price spreadsheet. Every component in the REC that consumes energy must be included in<br />

exactly one subsystem.<br />

No TPC-Energy secondary metrics are reported.<br />

For each defined subsystem, the calculations defined for the TPC-Energy Secondary Metrics in Clause 3.3 must<br />

be reported, using the Performance Metric of the entire SUT and the energy consumption for each REC<br />

subsystem.<br />

No TPC-Energy secondary metrics are reported.<br />

H.2.3. Idle Power reporting<br />

The Idle Power measurement/calculation for the REC must be reported as numerical quantities.<br />

PMU<br />

<strong>Full</strong> Load<br />

Average Watts<br />

Reading<br />

% of Reading<br />

Uncertainty<br />

Watts<br />

Reading<br />

Correction<br />

Wattage<br />

Range<br />

Setting<br />

Idle Load Energy<br />

% of Range<br />

Uncertainty<br />

Wattage<br />

Range<br />

Correction<br />

Total Wattage<br />

Correction<br />

Accuarcy<br />

Correction<br />

Factor<br />

<strong>Report</strong>ed<br />

Watt /<br />

Seconds<br />

Idle MI<br />

Seconds: 600.0<br />

Adjusted Watt<br />

/<br />

Seconds<br />

<strong>Report</strong>ed<br />

Seconds<br />

Adjusted<br />

Average<br />

Watts<br />

DB Server PMU‐1 263.9 0.10% +0.26 1500 0.10% +1.50 +1.76 0.67% 158,602.0 159,662.1 600.0 266.1<br />

DB Server PMU‐2 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 600.0 -<br />

DB Server PMU‐3 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 600.0 -<br />

DB Server Total 263.9 158,602.0 159,662.1 600.0 266.1<br />

Storage PMU‐1 0.0 0.10% +0.00 0 0.10% +0.00 +0.00 0.00% - - 600.0 -<br />

Storage PMU‐2 0.0 0.10% +0.00 0 0.10% +0.00 +0.00 0.00% - - 600.0 -<br />

Storage PMU‐3 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 600.0 -<br />

Storage PMU‐4 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 600.0 -<br />

Storage Total 0.0 - - 600.0 -<br />

Monitor Name Plate 28.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% 16,800.0 16,800.0 600.0 28.0<br />

Misc PMU‐2 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 600.0 -<br />

Misc PMU‐3 0.0 0.00% +0.00 0 0.00% +0.00 +0.00 0.00% - - 600.0 -<br />

Misc Total 28.0 16,800.0 16,800.0 600.0 28.0<br />

REC Total 291.9 175,402.0 176,462.1 294.1<br />

If TPC-Energy Secondary Metrics are reported, then the Idle Power measurement/calculation for each<br />

subsystem must also be reported as numerical quantities.<br />

No TPC-Energy secondary metrics are reported.<br />

The length of time between the conclusion of the performance measurement and the start of the idle<br />

measurement must be reported.<br />

Idle measurement was started 6 minutes after the conclusion of the performance measurement.<br />

The duration of the idle measurement must be reported<br />

HP TPC-H FULL DISCLOSURE REPORT 96 July, 2010<br />