VERFASSER :<br />

BAUWERK : STRASSEN- UND WEGBRÜCKEN DATUM: 01.12.2007<br />

1.4 Quality Assurance<br />

QS-System<br />

The quality management system meets the DIN EN ISO 9001 standards. It was certified by DVS-Zert.<br />

Monitoring<br />

The Monitoring is divided into external and internal supervision. The documents and working instructions<br />

that form the basis of this TECHNICAL APPROVAL will be tested on their compliance with these regulations.<br />

Responsible for the External Monitoring is the<br />

German Federal Materials Testing Institute of the University Stuttgart<br />

Pfaffenwaldring 32/ D-70569 Stuttgart<br />

1.5 <strong>Approval</strong> and Verifications<br />

<strong>Approval</strong>s for Welding<br />

Munich Factory "The Extensive Proof of Suitability" according to DIN 18800 Part 7, DIN 15018<br />

(DIN 18809 included in DIN 15018), DIN 4099 and DS 804<br />

Bernsdorf Factory<br />

"The Extensive Proof of Suitability" according to DIN 18800 Part 7, DIN 4099 and<br />

DS 804 (DIN 18809)<br />

Branch Lünen "The Extensive Proof of Suitability" according to DIN 18800 Part 7, DIN 18809,<br />

and DS 804<br />

<strong>Approval</strong> of Factory Welders<br />

The condition required to obtain an <strong>Approval</strong> is a Licence according to DIN EN 287-1.<br />

<strong>Approval</strong> of site Welders<br />

According to component demands, only welders with a valid Verification Certificate according to DIN EN 287-1<br />

and Concrete Reinforcement Steel Welder’s Verification according to DIN 4099 are deployed. The related verification<br />

is avaliable on the site.<br />

1.6 Producer's statement<br />

MAURER SÖHNE GmbH & Co. KG herewith declare<br />

•Compliance with the design conditions of all documents with the test certificates, listed in the index from 1.12.2007<br />

•Compliance with quality assurance standards listed in the supervision contract from 01 st April 2002.<br />

Munich, 01 st December 2007<br />

Company Management<br />

<strong>Technical</strong> Office<br />

BAUTEIL : SCHWENKTRAVERSEN-DEHNFUGE DS160 BIS 1200<br />

BLOCK : 1 - VERANTWORTLICHE SEITE: 2<br />

VORGANG : REGELPRÜFUNG NACH TL/TP FÜ (STAND: 03/05)<br />

ARCHIV NR.<br />

Regelprüfung<br />

Nr. 05/07 vom 20.12.07<br />

Diese Unterlagen sind Eigentum der MAURER SÖHNE GmbH & Co. KG. Jede Art der Vervielfältigung - auch auszugsweise - bedarf der Zustimmung.<br />