High Pressure Mercury Lamps<br />

<strong>Heraeus</strong> manufactures low and high pressure mercury<br />

vapour lamps used for applications such as photochemical<br />

processing, fluorimetry, mercury analysers, medical and<br />

environmental equipment, and fixed wavelength detectors.<br />

HPK 125W – Features<br />

<strong>Heraeus</strong> high pressure lamp type HPK for use in scientific<br />

instrumentation and other applications requiring high<br />

stability UV radiation combined with an accurate position<br />

for the arc.<br />

At a power consumption of 125 Watt the lamp provides<br />

maximum energy at 365nm with substantial radiation<br />

at 435, 313, 254 and 405nm. In addition there is a<br />

continuum from 200 to 600 nm peaking at 260nm with<br />

approximately 20% of the maximum energy measured in<br />

the line spectrum.<br />

Applications<br />

Analytical Instruments<br />

Photochemical processing<br />

Fluorimetry<br />

Mercury analysers<br />

Environmental equipment<br />

Fixed wavelength detectors<br />

Lamp Mounting<br />

The lamp should ideally be mounted with the base down<br />

and a maximum inclination from the vertical of ± 30°.<br />

The lamp can be mounted in a BA15d connector. Due<br />

to the high level of UV radiation extreme care should be<br />

taken in following the local health and safety precautions<br />

for operators working in the presence of ultra violet light.<br />

Power Supply<br />

The HPK mercury lamp is operated with the <strong>Heraeus</strong><br />

Ballast C440.<br />

Specifications Lamp Type HPK 125W<br />

Lamp Type HPK 125W<br />

Part number 80017490<br />

Wattage 125 Watt<br />

Ignition voltage 180 VAC<br />

Running voltage 125 VAC<br />

Current 1150 mAAC<br />

Stabilisation time 2 mins<br />

Output drop at 1000 hrs 20 %<br />

Life 2000 hrs<br />

Ballast C440<br />

Ballast Part No. 80017562<br />

3500<br />

3000<br />

2500<br />

2000<br />

1500<br />

1000<br />

Typical Spectrum High Pressure Mercury Lamps<br />

Spectral Irradiance mWm -2/nm -1 @ 300mm<br />

500<br />

253.7<br />

265.2<br />

280.4<br />

280.4<br />

302.1<br />

313.2<br />

334.1<br />

0<br />

200 250 300 350 400 450 500 550 600 650 700<br />

Wavelength (nm)<br />

53±3<br />

365.0<br />

98±3<br />

404.6<br />

435.8<br />

32±1,5<br />

546.1<br />

576.9<br />

579.0<br />

Ballast 125w<br />

TRMS Current 1150ma<br />

TRMS Voltage 127V<br />

Band Width 1nm<br />

Dimensional Outline<br />

HPK 125W Lamp


3<br />

<strong>Headline</strong><br />

Subheadline<br />

St-Series - Features<br />

<strong>Heraeus</strong> mercury lamps of the St-Series are stabilized high<br />

pressure lamps developed for analytical applications. The<br />

emission lines have narrow bands, virtually monochromatic<br />

spectrum at constant, well reproducible wavelengths.<br />

Stable Output<br />

Various capabilities have been developed to improve the<br />

light stability:<br />

electrode stabilized high pressure lamp operated with a<br />

DC voltage<br />

a specific design of anode and cathode make sure that<br />

the discharge arc does not move during operation. Therewith<br />

it will be achieved that the geometrical axis of the arc<br />

remains in the same position (St 75).<br />

An outer protection tube helps to minimize the outer<br />

thermal influences onto the discharge. (St 46, St 49/1..)<br />

All measures lead to a very low noise – in the order of<br />

0.1 %. The most favourable values of drift and noise are<br />

achieved when only the middle part of the light arc is<br />

used as the light source.<br />

Applications<br />

Photometers Fluorimeters Polarimeters<br />

Densitometers Other optical equipment<br />

These lamps should be mounted with the base down and an<br />

inclination from the vertical of less than ± 20°. Lamps in DC<br />

operation has to be operated with the anode at the bottom.<br />

Spectral Irradiance<br />

Specifications St Lamp Types<br />

0<br />

200 300 400<br />

500<br />

600<br />

Wavelength (nm)<br />

Lamp Type St 46 St 49/1 St 75<br />

Part number 56001333 45000124 56001171<br />

Total length (mm) 90 136 120<br />

Light centre (mm) 43.5 + 0.5 85 + 3 51 + 0.5<br />

Arc length (mm) 11.5 25 20<br />

Outer bulb diameter (mm) 19 22 without<br />

Base Noval E 27 BA 20d<br />

Type of current DC AC DC<br />

Wattage (W) 33 35 80<br />

Ignition voltage (V) 330 230 800<br />

Lamp voltage (V) 55 + 5 40 + 5 88 + 7<br />

Lamp current (A) 0.6 1.0 0.9<br />

Luminous intensity (cd) 95 24 220<br />

Luminance (cd cm-2 ) 380 56 530<br />

UV-A Radiance (mW cm-2 sr-1 ) 510 68 680<br />

UV-B Radiance (mW cm-2 sr-1 ) 480 72 840<br />

Lifetime (h) 1000 1000 1000<br />

100<br />

90.0<br />

80.0<br />

70.0<br />

60.0<br />

50.0<br />

40.0<br />

30.0<br />

20.0<br />

10.0<br />

Spectrum of Lamp Type St 46<br />

253.7<br />

302.1<br />

313.2<br />

365.0<br />

404.6<br />

435.8<br />

546.1


Low Pressure Mercury Lamps<br />

NK-Series - Features<br />

<strong>Heraeus</strong> mercury lamps of the NK-Series are low pressure,<br />

cold cathode UV lamps developed for applications in<br />

analytical instruments. They mainly emit the monochromatic<br />

mercury resonance line 254nm.<br />

<strong>Heraeus</strong> NK lamps have been optimized for high radiance<br />

of the 254nm line obtained by having an emitting light<br />

part that is shorter resp. designed as a capillary compared<br />

to conventional UV lamps. This feature is particular<br />

needed for light sources in optical instruments such like<br />

photometer.<br />

The discharge tube is made of high quality fused silica.<br />

NK lamps are also available with a special quartz jacket<br />

that eliminates 185nm radiation for ozone-free operation.<br />

For low pressure mercury UV lamps basically the emitted<br />

radiation intensity mainly depends on the temperature of<br />

the mercury and therefore strongly from the abient temperature.<br />

The maximum intensity is reached when the<br />

bulb has a temperature of approximately 40°C.<br />

Specifications NK Lamp Types<br />

Spectrum NK Lamp Types<br />

Spectral Irradiance mWm-2/nm-1 @ 300mm<br />

Lamp Type NK 4/4 NK 6/12<br />

Part number 56001636 56001781<br />

Total length (mm) 113 140<br />

Arc length (mm) 10 65<br />

Outer bulb diameter (mm) without 8.4<br />

Base without metal tube<br />

Lead length (mm) 290 800<br />

Type of current DC or AC AC<br />

Wattage (W) 3.5 6<br />

Ignition voltage (V) 900DC/600AC 900DC/600AC<br />

Lamp voltage (V) 220 300<br />

Lamp current (mA) 0.02 0.025<br />

Radiant Flux@254 nm (mW) 500 800<br />

Radiance@254 nm (mW/cm2sr) 15 15<br />

Lifetime, guaranteed (h) 2000 2000<br />

Power supply CXA-P20L-L CXA-P20L-L<br />

Part no. power supply 80020475 80020475<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

253.7<br />

313.2<br />

365.0<br />

404.6<br />

435.8<br />

-20<br />

200 250 300 350 400 450 500 550 600 650 700<br />

Wavelength (nm)<br />

546.1<br />

Mains 230v<br />

Band Width 1nm


5<br />

<strong>Headline</strong><br />

Subheadline<br />

HG-2 Lamp – Features<br />

<strong>Heraeus</strong> has developed a compact low pressure , low<br />

voltage Mercury vapour lamp type HG2, principally for<br />

use in scientific instrumentation.<br />

This lamp has a highly stable output predominantly at<br />

the 253.7nm Mercury line. When use with the Heraus<br />

C430 power supply the line output is much higher than,<br />

and the stability comparable to, that of a Deuterium<br />

lamp. Other lines, which total 20% of the output, are at<br />

313nm, 365nm, 404nm and 435nm.<br />

The HG2 has a strike voltage requirement of just 21V<br />

and a typical power requirement of 2.7 Watt, making this<br />

lamp especially suitable for use in portable instruments.<br />

Lamp Mounting<br />

It is advisible that the lamp should be mounted with<br />

the base and leads uppermost. Any clamp around the<br />

lamp envelope should be at the base end of the lamp.<br />

The clamp should be of low thermal capacity and poor<br />

thermal conduction. If the mount is such that it cools the<br />

lamp significantly Mercury can be condensed in this region<br />

adversely affecting the performance of the lamp. The<br />

lamp, which is temperature sensitive, must be protected<br />

from draughts if optimum stability is to be achieved.<br />

Dimensional Outline HG-2 Lamp<br />

Lead length<br />

280 ±5<br />

37±2<br />

50±1<br />

Discharge<br />

Ø22±1<br />

max 5<br />

Specifications HG-2 Lamp<br />

Lamp Type HG-2<br />

Part number 80017485<br />

Wattage (W) 2.7<br />

Ignition voltage (V) 21 max<br />

Lamp voltage (VDC) 8-14@150mA<br />

Lamp current (mADC) 100-300, 150mA recom<br />

Lead length (mm) 280<br />

Base without<br />

Filament voltage warm-up (V DC) 5-7<br />

Filament running voltage (V DC) 3-4.5<br />

Filament current warm-up (mA DC) 400 @ 6V DC<br />

Filament run current (mA DC) 250 @ 3.5 V DC<br />

Output at lamp surface@254 nm 15 mW/cm2 with 150 mA anode current<br />

Output at lamp surface@254 nm 30 mW/cm2 with 300 mA anode current<br />

Lifetime@150mA 4000 h typical<br />

Power supply C430B2<br />

Part no. power supply 80017411<br />

Spectrum HG-2 Lamp<br />

Percent<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

253.7<br />

313.2<br />

365.0<br />

404.6<br />

0<br />

220 300<br />

400<br />

500<br />

600<br />

Wavelength (nm)<br />

435.8<br />

546.1


6<br />

Black Light Blue Lamp<br />

Black Light Blue Lamp<br />

<strong>Heraeus</strong> manufactures the TW6W black light blue<br />

fluorescent lamp that emits ultraviolet radiation in the<br />

300-400 nm range.<br />

Applications<br />

The spectral characteristics of the lamp allows the<br />

excitation of luminescence which can reveal fluorescence<br />

and phosphorescence of stamps, dark room paints, bank<br />

notes, papers and in the geological investigation of stones<br />

and rocks.<br />

Lamp Mounting<br />

The lamp is fitted with an E27 screw base and can be<br />

operated in any orientation.<br />

Power Supply<br />

The ability to run the lamp directly from mains voltage<br />

enables the product to be used in applications where<br />

space is a premium.<br />

Dimensional Outline Black Light Blue Lamp<br />

E27<br />

E27<br />

92±2<br />

max 157,5<br />

77±2<br />

Ø28<br />

Specifications Black Light Blue Lamp<br />

Lamp Type TW6W<br />

Part number 80017695<br />

Lamp voltage 220 VAC<br />

Lamp current 27mAAC<br />

Output 50mW<br />

Average Life 2500 h<br />

Spectrum Black Light Blue Lamp<br />

Spectral Irradiance mWm -2/nm-1 @ 300mm<br />

3.5<br />

3<br />

2.5<br />

2<br />

1.5<br />

1<br />

0.5<br />

0<br />

-0.5<br />

200 250 300 350 400 450 500 550 600 650 700<br />

Irradiance (µW cm -2 @ 50cm)<br />

0ß<br />

30ß<br />

60ß<br />

365.0<br />

404.6<br />

1<br />

2<br />

uW/cm 2UV<br />

90ß<br />

Mains 230v<br />

Band Width 1nm<br />

Wavelength (nm)<br />

120ß<br />

180ß<br />

150ß


7<br />

Germicidal <strong>Headline</strong> Lamp<br />

Subheadline<br />

Germicidal Lamp<br />

<strong>Heraeus</strong> manufactures the TUV 6WE germicidal lamp, a<br />

low pressure mercury vapoure device emitting radiation<br />

primarily at 254nm.<br />

Applications<br />

The primary use of the TUV6WE lamp is for sterilization<br />

of small compartments where the compact size and direct<br />

mains operation are of particular advantage.<br />

Lamp Mounting<br />

The lamp is fitted with an E27 screw base and can be<br />

operated in any orientation.<br />

Power Supply<br />

The TUV 6WE lamp operates on 220V mains voltage and<br />

therefore no power supply or ballast is required.<br />

Specifications Germicidal Lamp<br />

Lamp type TUV 6WE<br />

Part number 80017693<br />

Lamp voltage 220 VAC<br />

Lamp current 27 mA<br />

Irradiance @ 1meter 0.85 µW/cm2 Total output<br />

Reduction in output over<br />

120 mW<br />

time between 100 and 2500 h 25%<br />

Average life 2500 h<br />

Spectrum Germicidal Lamp<br />

Spectral Irradiance mWm-2/nm-1 @ 300mm<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

253.7<br />

313.2<br />

365.0<br />

404.6<br />

435.8<br />

-20<br />

200 250 300 350 400 450 500 550 600 650 700<br />

Wavelength (nm)<br />

Dimensional Outline Germicidal Lamp<br />

E27<br />

92±2<br />

max 157,5<br />

77±2<br />

546.1<br />

Mains 230v<br />

Band Width 1nm<br />

Ø28


Technical data sheets including spectrum and technical drawing are available for all lamp types. Please contact us!<br />

Safety warning: UV radiation damages skin and eyes. Wear protective glasses, gloves and clothing.<br />

www.heraeus-noblelight.com<br />

Region Germany 1<br />

<strong>Heraeus</strong> <strong>Noblelight</strong> Company Name GmbH<br />

Muster <strong>Heraeus</strong>straße Europa 12-14 Division<br />

Muster-Ring 63450 Hanau29<br />

63801 Phone Beispielstadt +49 6181 35-5085 (D)<br />

Telefax Freecall + +49 49 (0) 6181 800.35 35-7970<br />

hng-analyticallamps@heraeus.com<br />

sales@heraeus-konzern.com<br />

www.heraeus-konzern.com<br />

United Region Kingdom 2<br />

<strong>Heraeus</strong> <strong>Noblelight</strong> Company Analytics Name Ltd.<br />

2-4 Muster Nuffield Europa Close Division<br />

Cambridge Muster-Ring CB4 29 1SS<br />

Phone 63801 Beispielstadt +44 1223 424100 (D)<br />

Telefax Freecall +44 + 49 1223 (0) 800.35 426338<br />

sales@heraeus-konzern.com<br />

hna-analytics@heraeus.com<br />

www.heraeus-konzern.com<br />

USA Region 3<br />

<strong>Heraeus</strong> <strong>Noblelight</strong> Company Name LLC<br />

1520C Muster Broadmoor Europa Division Blvd.<br />

Buford, Muster-Ring GA 30518 29<br />

Phone 63801 Beispielstadt +1 678 835 5764 (D)<br />

Telefax Freecall +1 + 49 678 (0) 835 800.35 5765<br />

analytics-usa@heraeus.com<br />

sales@heraeus-konzern.com<br />

www.heraeus-konzern.com<br />

PR Region China 4<br />

<strong>Heraeus</strong> <strong>Noblelight</strong> Company (Shenyang) Name Ltd.<br />

4F, Muster 11th Building, Europa No. Division 99 Tianzhou Rd.<br />

Shanghai, Muster-Ring 200233 29<br />

Phone 63801 Beispielstadt +86 (21) 5445 (D) 2255<br />

Telefax Freecall + +86 49 (0) (21) 800.35 5445 2410<br />

info.hns@heraeus.com<br />

sales@heraeus-konzern.com<br />

www.heraeus-konzern.com<br />

Technical data are subject to WM-Nr.: modification. 00100121-3-09/05 HNG B147 E. ORT/WÄN 02/2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!