Headline - Heraeus Noblelight
Headline - Heraeus Noblelight
Headline - Heraeus Noblelight
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
optics + analytics<br />
Line Sources<br />
for Photometers, Densitometers, Polarimeters<br />
and other Optical Equipment
2<br />
High Pressure Mercury Lamps<br />
<strong>Heraeus</strong> manufactures low and high pressure mercury<br />
vapour lamps used for applications such as photochemical<br />
processing, fluorimetry, mercury analysers, medical and<br />
environmental equipment, and fixed wavelength detectors.<br />
HPK 125W – Features<br />
<strong>Heraeus</strong> high pressure lamp type HPK for use in scientific<br />
instrumentation and other applications requiring high<br />
stability UV radiation combined with an accurate position<br />
for the arc.<br />
At a power consumption of 125 Watt the lamp provides<br />
maximum energy at 365nm with substantial radiation<br />
at 435, 313, 254 and 405nm. In addition there is a<br />
continuum from 200 to 600 nm peaking at 260nm with<br />
approximately 20% of the maximum energy measured in<br />
the line spectrum.<br />
Applications<br />
Analytical Instruments<br />
Photochemical processing<br />
Fluorimetry<br />
Mercury analysers<br />
Environmental equipment<br />
Fixed wavelength detectors<br />
Lamp Mounting<br />
The lamp should ideally be mounted with the base down<br />
and a maximum inclination from the vertical of ± 30°.<br />
The lamp can be mounted in a BA15d connector. Due<br />
to the high level of UV radiation extreme care should be<br />
taken in following the local health and safety precautions<br />
for operators working in the presence of ultra violet light.<br />
Power Supply<br />
The HPK mercury lamp is operated with the <strong>Heraeus</strong><br />
Ballast C440.<br />
Specifications Lamp Type HPK 125W<br />
Lamp Type HPK 125W<br />
Part number 80017490<br />
Wattage 125 Watt<br />
Ignition voltage 180 VAC<br />
Running voltage 125 VAC<br />
Current 1150 mAAC<br />
Stabilisation time 2 mins<br />
Output drop at 1000 hrs 20 %<br />
Life 2000 hrs<br />
Ballast C440<br />
Ballast Part No. 80017562<br />
3500<br />
3000<br />
2500<br />
2000<br />
1500<br />
1000<br />
Typical Spectrum High Pressure Mercury Lamps<br />
Spectral Irradiance mWm -2/nm -1 @ 300mm<br />
500<br />
253.7<br />
265.2<br />
280.4<br />
280.4<br />
302.1<br />
313.2<br />
334.1<br />
0<br />
200 250 300 350 400 450 500 550 600 650 700<br />
Wavelength (nm)<br />
53±3<br />
365.0<br />
98±3<br />
404.6<br />
435.8<br />
32±1,5<br />
546.1<br />
576.9<br />
579.0<br />
Ballast 125w<br />
TRMS Current 1150ma<br />
TRMS Voltage 127V<br />
Band Width 1nm<br />
Dimensional Outline<br />
HPK 125W Lamp
3<br />
<strong>Headline</strong><br />
Subheadline<br />
St-Series - Features<br />
<strong>Heraeus</strong> mercury lamps of the St-Series are stabilized high<br />
pressure lamps developed for analytical applications. The<br />
emission lines have narrow bands, virtually monochromatic<br />
spectrum at constant, well reproducible wavelengths.<br />
Stable Output<br />
Various capabilities have been developed to improve the<br />
light stability:<br />
electrode stabilized high pressure lamp operated with a<br />
DC voltage<br />
a specific design of anode and cathode make sure that<br />
the discharge arc does not move during operation. Therewith<br />
it will be achieved that the geometrical axis of the arc<br />
remains in the same position (St 75).<br />
An outer protection tube helps to minimize the outer<br />
thermal influences onto the discharge. (St 46, St 49/1..)<br />
All measures lead to a very low noise – in the order of<br />
0.1 %. The most favourable values of drift and noise are<br />
achieved when only the middle part of the light arc is<br />
used as the light source.<br />
Applications<br />
Photometers Fluorimeters Polarimeters<br />
Densitometers Other optical equipment<br />
These lamps should be mounted with the base down and an<br />
inclination from the vertical of less than ± 20°. Lamps in DC<br />
operation has to be operated with the anode at the bottom.<br />
Spectral Irradiance<br />
Specifications St Lamp Types<br />
0<br />
200 300 400<br />
500<br />
600<br />
Wavelength (nm)<br />
Lamp Type St 46 St 49/1 St 75<br />
Part number 56001333 45000124 56001171<br />
Total length (mm) 90 136 120<br />
Light centre (mm) 43.5 + 0.5 85 + 3 51 + 0.5<br />
Arc length (mm) 11.5 25 20<br />
Outer bulb diameter (mm) 19 22 without<br />
Base Noval E 27 BA 20d<br />
Type of current DC AC DC<br />
Wattage (W) 33 35 80<br />
Ignition voltage (V) 330 230 800<br />
Lamp voltage (V) 55 + 5 40 + 5 88 + 7<br />
Lamp current (A) 0.6 1.0 0.9<br />
Luminous intensity (cd) 95 24 220<br />
Luminance (cd cm-2 ) 380 56 530<br />
UV-A Radiance (mW cm-2 sr-1 ) 510 68 680<br />
UV-B Radiance (mW cm-2 sr-1 ) 480 72 840<br />
Lifetime (h) 1000 1000 1000<br />
100<br />
90.0<br />
80.0<br />
70.0<br />
60.0<br />
50.0<br />
40.0<br />
30.0<br />
20.0<br />
10.0<br />
Spectrum of Lamp Type St 46<br />
253.7<br />
302.1<br />
313.2<br />
365.0<br />
404.6<br />
435.8<br />
546.1
Low Pressure Mercury Lamps<br />
NK-Series - Features<br />
<strong>Heraeus</strong> mercury lamps of the NK-Series are low pressure,<br />
cold cathode UV lamps developed for applications in<br />
analytical instruments. They mainly emit the monochromatic<br />
mercury resonance line 254nm.<br />
<strong>Heraeus</strong> NK lamps have been optimized for high radiance<br />
of the 254nm line obtained by having an emitting light<br />
part that is shorter resp. designed as a capillary compared<br />
to conventional UV lamps. This feature is particular<br />
needed for light sources in optical instruments such like<br />
photometer.<br />
The discharge tube is made of high quality fused silica.<br />
NK lamps are also available with a special quartz jacket<br />
that eliminates 185nm radiation for ozone-free operation.<br />
For low pressure mercury UV lamps basically the emitted<br />
radiation intensity mainly depends on the temperature of<br />
the mercury and therefore strongly from the abient temperature.<br />
The maximum intensity is reached when the<br />
bulb has a temperature of approximately 40°C.<br />
Specifications NK Lamp Types<br />
Spectrum NK Lamp Types<br />
Spectral Irradiance mWm-2/nm-1 @ 300mm<br />
Lamp Type NK 4/4 NK 6/12<br />
Part number 56001636 56001781<br />
Total length (mm) 113 140<br />
Arc length (mm) 10 65<br />
Outer bulb diameter (mm) without 8.4<br />
Base without metal tube<br />
Lead length (mm) 290 800<br />
Type of current DC or AC AC<br />
Wattage (W) 3.5 6<br />
Ignition voltage (V) 900DC/600AC 900DC/600AC<br />
Lamp voltage (V) 220 300<br />
Lamp current (mA) 0.02 0.025<br />
Radiant Flux@254 nm (mW) 500 800<br />
Radiance@254 nm (mW/cm2sr) 15 15<br />
Lifetime, guaranteed (h) 2000 2000<br />
Power supply CXA-P20L-L CXA-P20L-L<br />
Part no. power supply 80020475 80020475<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
0<br />
253.7<br />
313.2<br />
365.0<br />
404.6<br />
435.8<br />
-20<br />
200 250 300 350 400 450 500 550 600 650 700<br />
Wavelength (nm)<br />
546.1<br />
Mains 230v<br />
Band Width 1nm
5<br />
<strong>Headline</strong><br />
Subheadline<br />
HG-2 Lamp – Features<br />
<strong>Heraeus</strong> has developed a compact low pressure , low<br />
voltage Mercury vapour lamp type HG2, principally for<br />
use in scientific instrumentation.<br />
This lamp has a highly stable output predominantly at<br />
the 253.7nm Mercury line. When use with the Heraus<br />
C430 power supply the line output is much higher than,<br />
and the stability comparable to, that of a Deuterium<br />
lamp. Other lines, which total 20% of the output, are at<br />
313nm, 365nm, 404nm and 435nm.<br />
The HG2 has a strike voltage requirement of just 21V<br />
and a typical power requirement of 2.7 Watt, making this<br />
lamp especially suitable for use in portable instruments.<br />
Lamp Mounting<br />
It is advisible that the lamp should be mounted with<br />
the base and leads uppermost. Any clamp around the<br />
lamp envelope should be at the base end of the lamp.<br />
The clamp should be of low thermal capacity and poor<br />
thermal conduction. If the mount is such that it cools the<br />
lamp significantly Mercury can be condensed in this region<br />
adversely affecting the performance of the lamp. The<br />
lamp, which is temperature sensitive, must be protected<br />
from draughts if optimum stability is to be achieved.<br />
Dimensional Outline HG-2 Lamp<br />
Lead length<br />
280 ±5<br />
37±2<br />
50±1<br />
Discharge<br />
Ø22±1<br />
max 5<br />
Specifications HG-2 Lamp<br />
Lamp Type HG-2<br />
Part number 80017485<br />
Wattage (W) 2.7<br />
Ignition voltage (V) 21 max<br />
Lamp voltage (VDC) 8-14@150mA<br />
Lamp current (mADC) 100-300, 150mA recom<br />
Lead length (mm) 280<br />
Base without<br />
Filament voltage warm-up (V DC) 5-7<br />
Filament running voltage (V DC) 3-4.5<br />
Filament current warm-up (mA DC) 400 @ 6V DC<br />
Filament run current (mA DC) 250 @ 3.5 V DC<br />
Output at lamp surface@254 nm 15 mW/cm2 with 150 mA anode current<br />
Output at lamp surface@254 nm 30 mW/cm2 with 300 mA anode current<br />
Lifetime@150mA 4000 h typical<br />
Power supply C430B2<br />
Part no. power supply 80017411<br />
Spectrum HG-2 Lamp<br />
Percent<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
253.7<br />
313.2<br />
365.0<br />
404.6<br />
0<br />
220 300<br />
400<br />
500<br />
600<br />
Wavelength (nm)<br />
435.8<br />
546.1
6<br />
Black Light Blue Lamp<br />
Black Light Blue Lamp<br />
<strong>Heraeus</strong> manufactures the TW6W black light blue<br />
fluorescent lamp that emits ultraviolet radiation in the<br />
300-400 nm range.<br />
Applications<br />
The spectral characteristics of the lamp allows the<br />
excitation of luminescence which can reveal fluorescence<br />
and phosphorescence of stamps, dark room paints, bank<br />
notes, papers and in the geological investigation of stones<br />
and rocks.<br />
Lamp Mounting<br />
The lamp is fitted with an E27 screw base and can be<br />
operated in any orientation.<br />
Power Supply<br />
The ability to run the lamp directly from mains voltage<br />
enables the product to be used in applications where<br />
space is a premium.<br />
Dimensional Outline Black Light Blue Lamp<br />
E27<br />
E27<br />
92±2<br />
max 157,5<br />
77±2<br />
Ø28<br />
Specifications Black Light Blue Lamp<br />
Lamp Type TW6W<br />
Part number 80017695<br />
Lamp voltage 220 VAC<br />
Lamp current 27mAAC<br />
Output 50mW<br />
Average Life 2500 h<br />
Spectrum Black Light Blue Lamp<br />
Spectral Irradiance mWm -2/nm-1 @ 300mm<br />
3.5<br />
3<br />
2.5<br />
2<br />
1.5<br />
1<br />
0.5<br />
0<br />
-0.5<br />
200 250 300 350 400 450 500 550 600 650 700<br />
Irradiance (µW cm -2 @ 50cm)<br />
0ß<br />
30ß<br />
60ß<br />
365.0<br />
404.6<br />
1<br />
2<br />
uW/cm 2UV<br />
90ß<br />
Mains 230v<br />
Band Width 1nm<br />
Wavelength (nm)<br />
120ß<br />
180ß<br />
150ß
7<br />
Germicidal <strong>Headline</strong> Lamp<br />
Subheadline<br />
Germicidal Lamp<br />
<strong>Heraeus</strong> manufactures the TUV 6WE germicidal lamp, a<br />
low pressure mercury vapoure device emitting radiation<br />
primarily at 254nm.<br />
Applications<br />
The primary use of the TUV6WE lamp is for sterilization<br />
of small compartments where the compact size and direct<br />
mains operation are of particular advantage.<br />
Lamp Mounting<br />
The lamp is fitted with an E27 screw base and can be<br />
operated in any orientation.<br />
Power Supply<br />
The TUV 6WE lamp operates on 220V mains voltage and<br />
therefore no power supply or ballast is required.<br />
Specifications Germicidal Lamp<br />
Lamp type TUV 6WE<br />
Part number 80017693<br />
Lamp voltage 220 VAC<br />
Lamp current 27 mA<br />
Irradiance @ 1meter 0.85 µW/cm2 Total output<br />
Reduction in output over<br />
120 mW<br />
time between 100 and 2500 h 25%<br />
Average life 2500 h<br />
Spectrum Germicidal Lamp<br />
Spectral Irradiance mWm-2/nm-1 @ 300mm<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
0<br />
253.7<br />
313.2<br />
365.0<br />
404.6<br />
435.8<br />
-20<br />
200 250 300 350 400 450 500 550 600 650 700<br />
Wavelength (nm)<br />
Dimensional Outline Germicidal Lamp<br />
E27<br />
92±2<br />
max 157,5<br />
77±2<br />
546.1<br />
Mains 230v<br />
Band Width 1nm<br />
Ø28
Technical data sheets including spectrum and technical drawing are available for all lamp types. Please contact us!<br />
Safety warning: UV radiation damages skin and eyes. Wear protective glasses, gloves and clothing.<br />
www.heraeus-noblelight.com<br />
Region Germany 1<br />
<strong>Heraeus</strong> <strong>Noblelight</strong> Company Name GmbH<br />
Muster <strong>Heraeus</strong>straße Europa 12-14 Division<br />
Muster-Ring 63450 Hanau29<br />
63801 Phone Beispielstadt +49 6181 35-5085 (D)<br />
Telefax Freecall + +49 49 (0) 6181 800.35 35-7970<br />
hng-analyticallamps@heraeus.com<br />
sales@heraeus-konzern.com<br />
www.heraeus-konzern.com<br />
United Region Kingdom 2<br />
<strong>Heraeus</strong> <strong>Noblelight</strong> Company Analytics Name Ltd.<br />
2-4 Muster Nuffield Europa Close Division<br />
Cambridge Muster-Ring CB4 29 1SS<br />
Phone 63801 Beispielstadt +44 1223 424100 (D)<br />
Telefax Freecall +44 + 49 1223 (0) 800.35 426338<br />
sales@heraeus-konzern.com<br />
hna-analytics@heraeus.com<br />
www.heraeus-konzern.com<br />
USA Region 3<br />
<strong>Heraeus</strong> <strong>Noblelight</strong> Company Name LLC<br />
1520C Muster Broadmoor Europa Division Blvd.<br />
Buford, Muster-Ring GA 30518 29<br />
Phone 63801 Beispielstadt +1 678 835 5764 (D)<br />
Telefax Freecall +1 + 49 678 (0) 835 800.35 5765<br />
analytics-usa@heraeus.com<br />
sales@heraeus-konzern.com<br />
www.heraeus-konzern.com<br />
PR Region China 4<br />
<strong>Heraeus</strong> <strong>Noblelight</strong> Company (Shenyang) Name Ltd.<br />
4F, Muster 11th Building, Europa No. Division 99 Tianzhou Rd.<br />
Shanghai, Muster-Ring 200233 29<br />
Phone 63801 Beispielstadt +86 (21) 5445 (D) 2255<br />
Telefax Freecall + +86 49 (0) (21) 800.35 5445 2410<br />
info.hns@heraeus.com<br />
sales@heraeus-konzern.com<br />
www.heraeus-konzern.com<br />
Technical data are subject to WM-Nr.: modification. 00100121-3-09/05 HNG B147 E. ORT/WÄN 02/2012