part 1: section 2.2 - RedBookLive
part 1: section 2.2 - RedBookLive
part 1: section 2.2 - RedBookLive
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
LOSS PREVENTION CERTIFICATION BOARD<br />
RED BOOK 2011<br />
Volume 2<br />
LIST OF APPROVED<br />
PRODUCTS AND SERVICES<br />
- PASSIVE FIRE PROTECTION PRODUCTS & SERVICES<br />
- SECURITY PROTECTION SYSTEMS<br />
- RELATED INSTALLERS<br />
THIS VOLUME ALSO INCLUDES:<br />
- MANAGEMENT SYSTEMS<br />
- CONSTRUCTION PRODUCTS<br />
A Specifier’s Guide
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT<br />
SYSTEMS AND ENVIRONMENTAL<br />
Foreword by Peter Holland CBE OStJ QFSM, President of the Chief Fire Officers Association<br />
and Chief Fire Officer of Lancashire Fire and Rescue Service<br />
Dear Specifier<br />
Continuing economic uncertainty makes us all aware of the need for protection against unexpected risks.<br />
In the life of any building, infrastructure or industrial facility, designers must increasingly consider business<br />
risk, especially potential exposure to the ‘unexpected’ such as fire or attack on security and security systems<br />
failure. By considering carefully what they specify, designers can mitigate these risks and demonstrate due<br />
diligence and engineering assurance whilst helping to prevent business losses.<br />
Business losses, whether caused by fire or security failure, can be large and disruptive; either is bad for<br />
publicity. And, although it is impossible to foresee all eventualities, by specifying effective, properly installed<br />
fire and security protection systems, the negative consequences of an incident can be reduced considerably.<br />
One of the best ways of doing this is to select products, systems and installers that are approved and listed by<br />
an independent third <strong>part</strong>y certification body such as LPCB. Third <strong>part</strong>y approval is confirmation that these<br />
products, systems and their installers have met and continue to meet appropriate standards. Independent<br />
third <strong>part</strong>y certification is the best and most trustworthy form of approval.<br />
As an independent certifier, LPCB has one of the most extensive fire and security testing laboratories in the<br />
world and its approvals are undertaken by a highly qualified team of expert scientists and engineers. LPCB<br />
develops standards with rigorous consultation and involvement of a wide range of stakeholders, including<br />
clients, insurers, manufacturers, public bodies and the emergency services. This all goes to make the LPCB<br />
certification mark a mark you can trust<br />
I have, therefore, no hesitation in recommending the products and services listed in the Red Book 2011 to<br />
you.<br />
ii 20 Nov 2011
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT<br />
SYSTEMS AND ENVIRONMENTAL<br />
Introduction<br />
Welcome to the 2011 Edition of the “Red Book”, the LPCB List of Approved Fire & Security Products and<br />
Services. The Loss Prevention Certification Board (LPCB) is <strong>part</strong> of BRE Global and together with the listings,<br />
the LPCB mark signifies that products and services have been approved by LPCB. The Red Book is an<br />
essential reference for specifiers, regulators, designers and end users of these products and services - if it is<br />
listed here, you know it has been checked out by people you can trust.<br />
BRE Global is <strong>part</strong> of the BRE Group under the BRE Trust. It is an independent third <strong>part</strong>y approvals body<br />
offering certification of fire, security and sustainability products and services to an international market.<br />
BRE Global - protecting people, property and the planet.<br />
The Red Book is divided into <strong>section</strong>s which list related groups of products and services such as suppression,<br />
security and so on. Each <strong>section</strong> also summarises the technical basis for the approval of each product or<br />
service. The Red Book should always be used in conjunction with rules, regulations and design specifications<br />
required by the relevant Authority.<br />
The 2011 edition of the Red Book comprises 2 Volumes:<br />
Volume 1:<br />
Volume 2:<br />
Fire Detection and Alarm products & services<br />
Fire Suppression products & services<br />
Related Installers<br />
Passive fire protection products & services<br />
Security Protection systems<br />
Related Installers<br />
Management Systems<br />
Construction products<br />
Listings are given in the name of the manufacturer or service provider, in alphabetical order.<br />
The Red Book is available free of charge in hard copy, CD and memory stick. It is also available on our<br />
website at www.redbooklive.com . The website gives you the most up to date<br />
information on which products are approved and in the unlikely event of suppliers needing to recall products<br />
or services or suspend production will identify these.<br />
Red Book updates<br />
Product and services approval details are amended regularly. To ensure that you are using the most up to<br />
date information please refer to www.<strong>RedBookLive</strong>.com .<br />
What is Third Party Approval?<br />
Third <strong>part</strong>y approval (or certification) is a conformity assessment process, carried out by a body that is<br />
independent of both supplier and customer organisations. It provides confirmation that products and services<br />
have met and will continue to meet the requirements of specified standards and other normative documents.<br />
Third <strong>part</strong>y approval provides a safeguard as to the performance of a product or service.<br />
LPCB third <strong>part</strong>y product approval schemes are quality assurance schemes and comprise initial type testing<br />
and technical evaluation, assessment and surveillance of the manufacturer’s quality system and production<br />
procedures, regular audit testing, labelling and listing.<br />
Similarly, LPCB schemes for suppliers of services (installers) are also quality assurance schemes comprising<br />
a technical assessment of a contractor’s capability, assessment and surveillance of the installer’s quality<br />
system and production procedures, regular inspection of completed installations and listing.<br />
20 Nov 2011 iii
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT<br />
SYSTEMS AND ENVIRONMENTAL<br />
Benefits of Third Party Approval<br />
A frequent concern of stakeholders is in knowing whether a product will perform in accordance with the stated<br />
specifications. These concerns can involve such product attributes as safety, health or environmental impacts,<br />
durability, compatibility, suitability for intended purposes or for stated conditions, and other similar<br />
considerations. These issues can all be addressed through product approvals.<br />
For specifiers, regulators, insurers, manufacturers and installers, the benefits of an LPCB approval are:<br />
For specifiers and regulators:<br />
<br />
<br />
<br />
Risk reduction - specifying LPCB approved products and services demonstrates due-diligence and best<br />
endeavour and mitigates against possible accusations of negligence.<br />
Avoidance of costly mistakes - you can trust LPCB approved products and services to conform each<br />
and every time.<br />
Time - using Red Book Live to search for and assess products and services can save you time.<br />
For manufacturers and installers:<br />
<br />
<br />
<br />
Increased global sales - LPCB approval is recognised and specified widely throughout the world. In<br />
some territories LPCB approval is a mandatory requirement.<br />
Added value of the product or service - LPCB approved products and services are recognised as<br />
providing added value given their ability to conform each and every time.<br />
Reduced liability - LPCB approved products and services demonstrate due-diligence which can reduce<br />
liability for both you and your customers.<br />
The LPCB Mark is a Mark you can Trust.<br />
The Third Party Approval Process<br />
LPCB offers approvals to existing British, European, International and LPCB’s own Loss Prevention<br />
Standards (LPSs). LPCB’s LPS approval schemes for both products and services are essentially level 5<br />
schemes, as described in ISO/IEC Guide 67, with the added requirement to have a quality system certificated<br />
to ISO 9001.<br />
The technical requirements of LPCB schemes are given in Loss Prevention Standards (LPSs). These<br />
documents are drafted by LPCB technical experts in conjunction with appropriate external experts.<br />
They are then peer reviewed by representatives from trade bodies, regulators, insurers, specifiers,<br />
manufacturers and other suppliers.<br />
Finally these documents are approved for use by the BRE Global Governing Body; the Body that oversees all<br />
of the certification activities of BRE Global including LPCB.<br />
On occasion, approval may be carried out to other international standards where this is appropriate to a<br />
<strong>part</strong>icular territory.<br />
Product schemes comprise:<br />
<br />
<br />
<br />
Initial type testing and evaluation of product, sampled by LPCB<br />
Approval and surveillance of the manufacturer’s (or supplier’s) quality management system to ISO 9001 (if<br />
you have products in for testing at LPCB, it generally costs little or no more to achieve ISO 9001<br />
certification).<br />
Assessment and surveillance of the manufacturer’s (or supplier’s) factory production control system (FPC)<br />
iv 20 Nov 2011
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT<br />
SYSTEMS AND ENVIRONMENTAL<br />
<br />
<br />
<br />
Periodic audit testing of the product from either the factory or marketplace<br />
Labelling or marking as appropriate.<br />
Listing of the approved product (service) in the Red Book.<br />
Installer schemes comprise:<br />
<br />
Technical assessment of the installation contractor’s capability<br />
Approval and surveillance of the contractor’s quality management system to ISO<br />
9001 or assessment against the requirements of the relevant Loss Prevention Standard where ISO 9001<br />
is not appropriate. (If you have applied for LPCB assessment of your services, it generally costs little or no<br />
more to achieve ISO 9001 certification).<br />
<br />
<br />
<br />
Regular surveillance inspections of on-going installations<br />
The issue of Certificates of Conformity to demonstrate compliance for each installation<br />
Listing of the approved installer in the Red Book.<br />
The LPCB Mark<br />
After approval of a product or service the manufacturer or service provider is allowed to place the LPCB<br />
certification mark, as shown below*, on the product, packaging and literature etc.<br />
Where LPCB holds accreditation through the United Kingdom Accreditation Service (UKAS), the approved<br />
company is allowed to include the UKAS logo alongside the LPCB mark for certain applications e.g.<br />
promotional literature or material and stationery, as shown below.*<br />
The LPCB scheme rules define how and where the marks can be used.<br />
The LPCB horseshoe is the mark you can trust and it is recognised in 45 countries around the world by<br />
regulators, specifiers, designers and end users.<br />
20 Nov 2011 v
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT<br />
SYSTEMS AND ENVIRONMENTAL<br />
Full details of LPCB accreditation can be found on the UKAS website at www.ukas.com<br />
.<br />
The products listed in Part 5 - Construction Products are approved under our BRE Certification brand:-<br />
Where management systems certification under a BRE Global accredited scheme is granted, the approved<br />
company is allowed to use the following mark on promotional literature or material and stationery<br />
All schemes are based on product testing/assessment and regular auditing.<br />
European Directives<br />
For products to be placed on the European market, manufacturers must comply with the regulatory<br />
requirements of a number of European Directives.<br />
To demonstrate compliance with these Directives, a manufacturer must make a declaration, based on an<br />
evaluation of the product, and affix the relevant mark.<br />
For some products the manufacturer will need to use the services of a Notified Certification Body or Notified<br />
Test Laboratory to demonstrate that the evaluation of the product has been carried out in whole or in <strong>part</strong> by a<br />
body independent of the manufacturer. Other products can merely be marked on the basis of a self<br />
declaration of conformity by the manufacturer.<br />
The relevant mark shows that a product meets minimum regulatory standards of health and safety as laid<br />
down in the Directives. It is not a quality mark and does not necessarily relate to the functional performance of<br />
the product.<br />
BRE Global is a Notified Body for:<br />
The Construction Products Directive (CPD)<br />
Pressure Equipment Directive (PED)<br />
Marine Equipment Directive (MED)<br />
Transportable Pressure Equipment Directive (TPED)<br />
vi 20 Nov 2011
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT<br />
SYSTEMS AND ENVIRONMENTAL<br />
Where the services of a Notified Body is required in order for a manufacturer to affix a mark to a product, BRE<br />
Global can provide a comprehensive service.<br />
Other Approvals<br />
BRE Global carries out approvals of a number of other construction products and management systems under<br />
other approval brand names.<br />
The details of these schemes are given in the relevant introductory <strong>section</strong>s.<br />
For Fire and Security Products and Services Trust the LPCB Mark<br />
20 Nov 2011 vii
CONTENTS<br />
1 Building products 1<br />
SECTION 1 Approved installers of passive fire protection products 3<br />
SECTION 1.1 LPS 1500 approved installer of fire resisting com<strong>part</strong>mentation system 4<br />
SECTION 1.2 LPS 1531 approved installer of passive fire protection products 5<br />
SECTION 2 Construction product systems (building envelope, roofing & <strong>part</strong>itions) 13<br />
SECTION 2.1 LPS 1181 Series 14<br />
SECTION 2.1.1 LPS 1181 lining materials 16<br />
SECTION 2.1.2 LPS 1181-1 cladding products used for the external envelope of<br />
buildings 17<br />
SECTION 2.1.3 LPS 1181-2 sandwich panels or built-up panel systems used internally in<br />
a building 36<br />
SECTION 2.1.4 LPS 1181-3 (draft) cladding used in pod construction 41<br />
SECTION <strong>2.2</strong> LPS 1208 composite construction elements 43<br />
SECTION 2.3 LPS 1581 external cladding systems on a masonry substrate 65<br />
SECTION 2.3.1 LPS 1581 external thermal insulated cladding (ETICS) on masonry<br />
substrates 66<br />
SECTION 2.3.2 LPS 1581 rain screen cladding systems (RSC) on masonry substrates 69<br />
SECTION 2.4 LPS 1582 external cladding systems supported by a structural steelwork<br />
frame 71<br />
SECTION 2.4.1 LPS 1582 external thermal insulated cladding (ETICS) supported by a<br />
structural steel frame 72<br />
SECTION 2.4.2 LPS 1582 rain screen cladding system (RSC) supported by a structural<br />
steel frame 75<br />
SECTION 2.5 Roofing products 76<br />
SECTION 2.5.1 Protection against fire from outside the building 77<br />
SECTION 2.5.2 Protection against fire from inside the building 84<br />
SECTION 2.6 Reaction to Fire (RTF) classifications for Materials and Products 85<br />
SECTION 3 LPS 1132 wall & floor penetration and linear gap seals 86<br />
SECTION 4 Structural steel fire protection 131<br />
SECTION 4.1 LPS 1107 structural steel fire protection - board and cementitious<br />
coverings 132<br />
SECTION 4.2 Structural steel fire protection - intumescent thin film coatings 155<br />
SECTION 5 Protective covering materials & scaffold cladding 160<br />
SECTION 5.1 LPS 1207 Protective covering materials 161<br />
SECTION 5.1.1 LPS 1207 protective covering materials - sheeting 162<br />
SECTION 5.1.2 LPS 1207 protective covering materials - pre-formed 172<br />
SECTION 5.2 LPS 1215 scaffold cladding materials 173<br />
SECTION 6 Cavity fire barriers 177<br />
SECTION 7 LPS 1195 temporary buildings for use on construction sites 179<br />
SECTION 8 Products assessed for use in surface and sub surface transport applications<br />
180<br />
SECTION 9 Fire Protected Timber Stairs 186<br />
2 Fire doors and shutters (incorporating installer scheme for fire and security doors)<br />
191<br />
SECTION 1.1 Firebreak doors and shutters 193<br />
SECTION 1.2 Lift landing doors 205<br />
SECTION 2 Fire and security door installers 206<br />
SECTION 3 Service and maintenance of doors 208<br />
3 Smoke and fire ventilation systems 213<br />
SECTION 1 Fire dampers 215<br />
viii 20 Nov 2011
CONTENTS<br />
SECTION 2 Fire resistant ducts 230<br />
SECTION 3 Smoke curtains 238<br />
SECTION 4 Powered smoke and heat exhaust ventilation 239<br />
SECTION 5 Grease Filters used in Commercial Kitchen Extract Systems 244<br />
4 Security protection products 245<br />
SECTION 1.1 Intruder detection equipment 247<br />
SECTION 1.2 Alarm transmission equipment and signalling systems 248<br />
SECTION 1.2.1 Alarm transmission equipment and systems 249<br />
SECTION 2 Safes, strongrooms and secure safe cabinets 252<br />
SECTION 2.1 Safes 253<br />
SECTION <strong>2.2</strong> Secure safe cabinets 260<br />
SECTION 2.3 Automatic teller machine (ATM) safes 263<br />
SECTION 2.4 Anti-bandit atm security devices 264<br />
SECTION 2.5 Deposit safes 265<br />
SECTION 2.6 Strongrooms 266<br />
SECTION 3 Secure office furniture 267<br />
SECTION 4 Secure enclosures 268<br />
SECTION 5 Physical security protection of buildings 287<br />
SECTION 5.1 High security doorsets 290<br />
SECTION 5.1.1 High security hinged doorsets with plain leaves 291<br />
SECTION 5.1.2 High security hinged doorsets with glazed leaves 412<br />
SECTION 5.1.3 High security hinged doorsets with other leaf designs 418<br />
SECTION 5.1.4 High security folding doorsets 420<br />
SECTION 5.2.1 Domestic doorsets approved to PAS 23-1 421<br />
SECTION 5.<strong>2.2</strong> Domestic doorsets approved to PAS 24-1 423<br />
SECTION 5.3 High security windows 425<br />
SECTION 5.3.1 High security windows - external windows 426<br />
SECTION 5.3.2 High security windows - secondary glazing systems 427<br />
SECTION 5.3.3 Rooflights 430<br />
SECTION 5.4 Domestic security windows 431<br />
SECTION 5.5 Security grilles, blinds and barsets 434<br />
SECTION 5.6 Security shutters 444<br />
SECTION 5.7 Perforated security screens 449<br />
SECTION 5.8 Louvre vents 450<br />
SECTION 5.9 Garage doors 452<br />
SECTION 6 Access covers and hatches 454<br />
SECTION 7 Secure walling systems 460<br />
SECTION 8 Secure roofing systems 471<br />
SECTION 9 Perimeter security products 473<br />
SECTION 9.1 Security fencing 475<br />
SECTION 9.2 Security gates 490<br />
SECTION 9.3 Turnstiles 492<br />
SECTION 10 Vehicle security barrier 493<br />
SECTION 11 Gas cylinder security devices 494<br />
SECTION 12 Physical security devices for computers and other ict equipment 497<br />
SECTION 13 Database management for asset marking 501<br />
SECTION 14 Asset marking systems 503<br />
SECTION 15 'Theft resistant' electronic products 506<br />
SECTION 16 Letter plates and letter boxes (mail boxes) 508<br />
SECTION 17 Key safes 510<br />
20 Nov 2011 ix
CONTENTS<br />
SECTION 18 Security glazing 511<br />
5 Construction products 513<br />
SECTION 1 Anchors, connectors, fasteners and fixing systems 515<br />
SECTION 2 Drainage and plumbing systems 516<br />
SECTION 3 Flooring systems 517<br />
SECTION 4 Groundworks and foundation systems 519<br />
SECTION 5 Membranes 520<br />
SECTION 6 Pre-fabricated building systems 522<br />
SECTION 7 Building systems for dwellings 525<br />
SECTION 8 Trussed rafters (timber) 528<br />
SECTION 9 Thermal insulation systems 529<br />
SECTION 10 Wall and roof cladding systems 531<br />
SECTION 11 Walling, roofing and <strong>part</strong>ition systems 534<br />
SECTION 12 Conservation of fuel and power 536<br />
6 Management system certification 537<br />
SECTION 1 Quality systems 539<br />
SECTION 2 Environmental systems 625<br />
SECTION 3 Health & safety certification BS OHSAS 18001 629<br />
x 20 Nov 2011
INDEX<br />
2<br />
2M KABLO SAN. ve TIC. A.S. 539<br />
A<br />
A & F Sprinklers Limited 539<br />
A M Profiles Limited 540<br />
A Steadman & Son 17, 540<br />
A.C. Plastic Industries Limited 540<br />
A.M. Fire Systems Limited 540<br />
Abbey Thermal Insulation Ltd 5<br />
Abbot Fire Group Limited 540<br />
AccentHansen 291, 541<br />
Actionair 215, 541<br />
AD Sprinkler Protection Limited 541<br />
Advanced Air (UK) Limited 223<br />
Advanced Electronics Limited 541<br />
AEI Cables Limited 541<br />
Alliance Valves and Piping Supplies Limited<br />
'AVPS' 542<br />
Alpine Fire Engineers Limited 542<br />
Aluroll Limited 444, 452, 542<br />
AMPAC Europe Limited 542<br />
Ampac Security Products Limited 542<br />
Andreu Barbera S.L. 193, 543<br />
Ansul Incorporated 543<br />
Anvil International Inc. 543<br />
Apollo (Beijing) Fire Products Co Ltd 543<br />
Apollo Fire Detectors Limited 544, 625<br />
APW Fire Protection Limited 544<br />
Aquacast (Fabrications) Limited 454<br />
Arabian Thermal Aire Industries Company Ltd 224<br />
ArcelorMittal Construction Belgium 43, 544<br />
ArcelorMittal Construction Belgium NV 17, 544<br />
Argus Fire Protection Company Limited 544, 629<br />
Argus-Spectrum Co 545<br />
Armstrong Priestley Limited 545<br />
Ascot Doors Limited 194, 208, 294, 445, 545<br />
Asgard Secure Steel Storage (a trading division of<br />
Flexiform Business Furniture Limited) 268<br />
Ashvale Fire Services Limited 545<br />
ASLR Fabrication Services Limited 545<br />
ATOM KABLO SANAYI VE TICARET A.S. 546<br />
Attenborough Doors Limited 194, 546<br />
Automatic Fire Control Limited 546<br />
Avert Fire (UK) Ltd 5<br />
B<br />
Bahra Cables Company 546<br />
Bailey & Mackey Limited 546<br />
Bainbridge International Limited 162<br />
Balmoral Sectional Tanks Limited 547<br />
Bangkok Cable Co Limited 547<br />
Bastion Security Installations Limited 269<br />
BBC Fire Protection Limited 547<br />
Beijing Siemens Cerberus Electronics Limited 547<br />
Besseges Limited 547<br />
Biamp Systems Corporation 548<br />
Blue Shield Fire Protection Limited 548<br />
Blyweert Beaufort Aluminium Limited 412<br />
Bolton Gate Co. Limited 420, 548<br />
Bond Engineering (Maintenance) Ltd 208<br />
Booth Industries Limited 548<br />
BPI Visqueen - Greenock 162, 548<br />
Bradbury Security 301, 412, 434, 498, 549<br />
Braithwaite Engineers Limited 549<br />
Brammall Inc. 549<br />
Britannia Kitchen Ventilation Limited 549<br />
British Gypsum 132<br />
Britton Merlin Limited 162<br />
Brucha Ges.m.b.H 18, 36<br />
Bryen & Langley Limited 5<br />
BSB Engineering Services Limited 224, 549<br />
BT Redcare 249<br />
Burton Safes Limited 550<br />
Bush (Fire Engineering) Limited 550<br />
C<br />
C W Fields and Son Limited 321, 413<br />
CA Group Limited 18, 550<br />
Cavicel SpA 550<br />
Ceodeux - Firetec 550<br />
Chaoyi Industry Development 551<br />
Charter Sepcialist Security Limited 551<br />
Checkmate Fire Solutions Ltd 6<br />
Chemring Energetics Limited 551<br />
Chubb Fire & Security Limited 551<br />
Circum Limited 552<br />
Clark Door Limited 194, 206, 552<br />
CLD Fencing Systems 475, 490, 552<br />
Clearway Environmental Services (UK) Limited<br />
323, 552<br />
Cleshar Contract Services Ltd 6<br />
Clymac Limited 552<br />
Compco Fire Systems Limited 553<br />
Computionics Limited (Trading as C-Tec) 553<br />
Control Equipment Limited 553<br />
Cooper Fulleon Limited 553<br />
Cooper Lighting and Safety Limited 554<br />
Cordek Limited 519<br />
Core Industrial Plastics Limited 163, 554<br />
Corecut Fire Protection (a division of Corecut<br />
Limited) 6<br />
Corus Panels and Profiles 19, 554<br />
Cranford Controls Limited 554<br />
Crawford UK Limited 208, 209, 554<br />
CTM Fire and Security Limited (Leyland & London<br />
Offices) 555<br />
Culimeta-Saveguard Limited 177, 555<br />
CVD Fire Protection Ltd 6<br />
D<br />
D.I.S. Sprinklers 555<br />
Daemon Fire and Security Limited 556<br />
Dalen Limited 498, 556<br />
Datatag ID Limited 501, 556<br />
Dätwyler Cables 556<br />
David Tyrrell T/A Nene Valley Acoustics 7<br />
Day-Impex Limited 556<br />
Debro Engineering and Presswork trading as<br />
Unistrut Ltd 557<br />
Defensor Group Limited 557<br />
Delta Extinctors S. A. 557<br />
20 Nov 2011 xi
INDEX<br />
Design & Supply Limited 324, 413, 557<br />
Dewey Waters Limited 557<br />
Digital Lighting (Dongguan) Co Ltd 558<br />
Don & Low Ltd, Nonwovens 163<br />
Doncaster Cables 558<br />
Dong-A Flexible Metal Tubes Co. Ltd. 558<br />
DoorTechnik 558<br />
Draka UK Limited 558<br />
Dryvit UK Limited 66, 72<br />
DS SMITH CORREX (Trading as a division of DS<br />
Smith Plastics Limited) 163, 559<br />
DST Group Ltd 86<br />
Dubai Cable Company (Private) Limited, Trading<br />
as Ducab 559<br />
Dudley Safes Limited 253, 260, 559<br />
Duplus Architectural Systems Limited 559<br />
DuPont de Nemours (Luxembourg) S.a.r.l. 520<br />
E<br />
E&S Heating & Ventilation Ltd 7<br />
Elta Fans Limited 239<br />
EMCOR Facilities Services Limited, EMCOR<br />
Specialist Services 560<br />
Emirates Fire Fighting Equipment Factory L.L.C.<br />
(FIREX) 560<br />
Energy Control Systems Ltd 536<br />
Envirowrap Solutions Limited 164, 173, 560<br />
Essex Safety Glass Limited 512, 560<br />
Eton Fire Limited 561<br />
Eurobond Laminates Limited & Eurobond Doors<br />
Limited 20, 37, 44, 561<br />
Eurobrick Systems Limited 531<br />
Euroclad Limited 22, 51, 561<br />
Euroform Products Limited 529<br />
Everday Technology Co. Limited 562<br />
Excel Industries Ltd 38, 562<br />
Eyston Company Ltd 562<br />
F<br />
F.V.S. Limited 562<br />
Fendor Limited 7, 414, 426, 562<br />
FES Limited, FES Sprinklers 563<br />
FFE Fire & Security Limited 563<br />
Fike Safety Technology Ltd 563<br />
Filling and Packing Materials Manufacturing<br />
Company (F.I.P.C.O.) 563<br />
Fire Alarm Solutions Limited 563<br />
Fire Defence (Northern) Limited 564<br />
Fire Defence plc 564<br />
Fire Logistics Limited 564<br />
Fire Protection Limited 7, 230, 564<br />
Fire Protection Solutions Ltd 8<br />
Fire Queen Limited 564<br />
Fire Security (Sprinkler Installations) Limited 565<br />
Fireproof Fire Engineering Limited 565<br />
Firespray International Limited 231, 565<br />
Firetecnics Systems Limited 565<br />
First Fire Protection Limited 565<br />
Flameshield Products Limited 233<br />
Flameshield Products Limited (Incorporating<br />
Flameshield Limited) 8, 566<br />
Flexiform Business Furniture Limited-incorporating<br />
Asgard Secure Steel Storage 566<br />
Florprotec Limited 164<br />
Fortress Doors N.I. Limited 566<br />
Franklin Hodge Industries Ltd. 566<br />
Frontier-Pitts Limited 492<br />
Fusion Building Systems 525<br />
G<br />
G & A Fire Protection Ltd 4, 8<br />
Galglass Limited 566<br />
Gaocheng General Foundry 567<br />
Gardner & Co (Kent) Ltd 8<br />
Giffen Group 9<br />
Gilray Plant Limited 165, 173<br />
Globe Fire Sprinkler Corporation 567<br />
Gloucester Composites Limited 567<br />
Godrej & Boyce Mfg. Co. Ltd. (Security Equipment<br />
Division) 254, 260<br />
Godwin Pumps Limited 567<br />
Goran Plastics 165, 567<br />
Gordonson Fire Protection Limited 568<br />
Grange Door Systems 206, 209, 568<br />
Grundfos Fire Systems 568<br />
gte Brandschutz AG 195, 568<br />
Gulf Security Technology Co. Ltd - A UTC Fire &<br />
Security Company 568<br />
Gunfire (Gunite Eastern Limited) 9<br />
Guthrie Douglas Limited 569<br />
GW Sprinkler A/S 569<br />
H<br />
H S Jackson & Son (Fencing) Limited, t/a<br />
Jacksons Fencing 476, 569<br />
H&S Decorating Specialists Ltd 9<br />
Haes Systems Limited 570<br />
Hall & Kay Fire Engineering (Manchester) 570<br />
Hall & Kay Fire Engineering (Paisley) 570<br />
Hall & Kay Fire Engineering (Thame) 570<br />
Hall & Kay Fire Engineering (West Midlands) 570<br />
Hall Fire Protection Limited 571<br />
Hallmark Fire (a division of SFS Fire Services Ltd)<br />
571<br />
Halton Foodservice Limited 244, 571<br />
Handan Boate Foundry Co Limited 571<br />
Hart Door Systems 196, 206, 571<br />
Harvel Plastics Incorporated (Bakersfield) 572<br />
Harvel Plastics Incorporated (Easton) 572<br />
Hemsec Manufacturing Limited 23, 52, 572<br />
Henry Lewis and Sons (Wireworkers) Limited 434,<br />
572<br />
Heras U.K. Fencing Systems 478, 572<br />
Hersey Meters 573<br />
Hershey Valve Co Limited 573<br />
Hillmoore Fire Protection Ltd 9<br />
Hilti (Gt Britain) Limited 573<br />
Hilti Aktiengesellschaft 86<br />
Hochiki America Corporation 573<br />
Hochiki Corporation 573<br />
Hochiki Europe (UK) Limited 574, 625<br />
Honeywell Life Safety Systems UK 574<br />
Honeywell Security UK Limited 574<br />
xii 20 Nov 2011
INDEX<br />
Horing LIH Industrial Co Ltd 574<br />
Hörmann KG Freisen 196<br />
Hosiden Besson Limited 575<br />
Huzhou Jiusheng Electric Co Ltd 575<br />
I<br />
Iceberg Building Services Limited 575<br />
Icopal Limited 77, 165, 174<br />
Icopal S. A. 471, 575<br />
IKO PLC 79<br />
Industrial Door Engineering Limited 197, 206, 209,<br />
575<br />
Industrial Textiles & Plastics Ltd 166, 174, 520<br />
Influx Measurements Limited 576<br />
Intelligent Engineering (UK) Ltd 517<br />
IPB N.V. 166, 576<br />
IR Martin Roberts, IR Security & Safety Limited<br />
326, 421, 423<br />
Irish Driver-Harris Company Limited 576<br />
Irish Industrial Tanks Limited 576<br />
Irish Sprinkler & Fire Protection Limited 576<br />
ISOCAB France S.A. 24, 53<br />
Isoclad Limited 54, 270, 460, 577<br />
J<br />
J & J Design Limited 577<br />
J Durrance & Co Ltd 198, 577<br />
J W Singer 625<br />
J. Bryceland Fire Systems Ltd 577<br />
Jeld-Wen UK Ltd 186<br />
John Brash & Company Ltd 531<br />
K<br />
K.P.F.P. Limited 578<br />
KAC Alarm Company Limited 578<br />
Kean Building & Fire Protection Services Limited<br />
578<br />
Kentallen Fire Protection Limited 578<br />
Kentec Electronics Limited 578<br />
Key Housing Limited 525<br />
Keystone Electric Wire & Cable Company Limited<br />
579<br />
Kidde Products Ltd, trading as AirSense<br />
Technology 579<br />
Kingfell Plc 579<br />
Kingspan Door Components S.A. 579<br />
Kingspan Insulation Limited 24, 580<br />
Kingspan Limited (t/a Profiles and Sections) 522,<br />
534<br />
Kingspan Ltd 25, 56, 580, 626, 629<br />
Kingspan Ltd trading as Kingspan Structural,<br />
Kingspan Fabrications, Kingspan Controlled<br />
Environments (KCE), Kingspan Profiles and<br />
Sections 580, 626, 629<br />
Kingspan Ltd. 27, 57, 580, 626, 630<br />
KingspanTarec Industrial Insulation Limited 581,<br />
626<br />
Klober Limited 521<br />
KME Italy SpA 581<br />
Kone PLC 206, 210<br />
L<br />
L.B.S. Group (incorporating L.B.S Security<br />
Services Limited - t/a Specialized Door<br />
Services, Russell Shutters, Olsen Shutters and<br />
Ranford Doors) 198, 210, 581<br />
Landskroon B.V. 166, 175<br />
Liddle Doors Limited 275, 328, 415, 435, 495, 581<br />
Lincs Doors Limited 198, 581<br />
Lingjack Engineering Works PTE Ltd 582<br />
Linkester Fire Protection Limited 582<br />
Lion Steelworks SDN. BHD. 257, 582<br />
Lixil Nittan Company Limited 582<br />
Lixil Nittan Electronic Company Limited 582<br />
Logix UK Limited (Simplipac) 534<br />
Lowrey Contractors Limited 275, 331, 418, 436,<br />
465, 583<br />
LPG Tecnicas en Extincion de Incendios, S.L. 583<br />
Lubrizol Advanced Materials Europe B.V.B.A 583<br />
M<br />
M & P Fire Solutions Ltd 584<br />
M J Quinn Integrated Services Ltd 10<br />
M. J. Quinn Integrated Services Limited 584<br />
Mansell Construction Services LTD 10<br />
Map Ventilation Limited 10<br />
Marmorit (UK) GmbH 532<br />
Mavili Elektronik Ticaret Ve Sanayi A.S. 584<br />
Max Frank Limited 515<br />
McAvoy Group Limited 179, 584<br />
MCT Brattberg AB 120, 180<br />
MECE Fire & Security Limited 585<br />
Mercian Shutters Limited 199, 207, 210, 585<br />
Mercury Engineering 585<br />
Metsec Limited 522<br />
Midas Technologies (GB) Limited 455, 585<br />
Middle East Insulation 199<br />
Midland Door Services Limited 585<br />
Midlands Fire Ltd 10<br />
MITIE McCartney Fire Protection Limited 586<br />
MITIE Property Services Limited - Midlands 4<br />
MITIE Technical Facilities Management Limited<br />
(MITIE Fire and Security Systems) 586<br />
Mitsubishi Plastics Inc 586<br />
Modgal Metal (99) Limited 587<br />
Modular Panel Systems Limited 28, 57<br />
Monarflex 167, 587<br />
Morgan Marine Limited 277, 587<br />
Morley-IAS Fire Systems By Honeywell 587<br />
MultiSteel Limited 415, 467<br />
N<br />
N.V. Joris IDE 29, 588<br />
Nanjing Fire Protection Technology Co Limited 588<br />
National Fire Fighting Manufacturing Company<br />
Limited (NAFFCO) 588<br />
National Sprinkler Company Limited 588<br />
Nexans Turkiye Endustri ve Ticaret A.S. 589<br />
NIBCO Inc 589<br />
Nields Plastic Company Limited 167, 589<br />
Nitin Fire Protection Industries Limited 589<br />
Nittan (UK) Limited 590<br />
Nittan Fire Protection System (Zhongshan)<br />
Company, Limited 590<br />
NK Fencing Limited 482<br />
NMC (UK) Limited 590<br />
20 Nov 2011 xiii
INDEX<br />
No Climb Products Limited 590<br />
Nobel Fire Systems 590<br />
Northern Ireland Plastics Limited 167, 591<br />
Notifier Fire Systems by Honeywell 591<br />
Nu-Form Fire UK Limited 591<br />
O<br />
Ockwells Limited 167, 172<br />
Olympic Fire Protection Limited 591<br />
O'Mahony Contractors Ltd 11<br />
Ondaplast SpA 168<br />
P<br />
P&M Group Ltd trading as ISD 4, 11<br />
Pace Technology Co. Limited 591<br />
Panel Projects Limited 58, 592<br />
Paneltex Limited 38<br />
Paroc Panel System Oy Ab 58, 592<br />
Patterson Pump Ireland Limited 592<br />
PEL Services Limited 592<br />
Pendle Designs Limited 592<br />
Peripheral Support Services Limited 593<br />
Permanite Asphalt 83<br />
PermaRock Products Limited 532<br />
Pittway Tecnologica Srl. 593<br />
Portakabin Ltd 41<br />
Potter Electric Signal Company 593<br />
Powershield Doors Limited 332, 593<br />
Pressex UK Limited 264, 593<br />
Prestige Fire Door Services Limited 207<br />
PRO TEC Vinduer A/S 431<br />
Professional Barrier Systems Limited279, 436, 594<br />
Project Fire Products Limited (incorporating<br />
Project Fire Engineers) 594, 626<br />
Promat UK Ltd 60, 132, 155<br />
Protec Camerfield Limited 594<br />
Protec Fire Detection plc 594<br />
Protec International Limited 168, 172, 175, 595,<br />
627<br />
Protecta Screen Ltd 169<br />
Provincial Sprinkler Co. Limited 595<br />
Prysmian Cables & Systems Limited 595<br />
Prysmian Cables & Systems Ltd 595<br />
Prysmian Power Cables & Systems Australia Pty<br />
Limited 596<br />
PSF Wales Limited 279, 339, 596<br />
Pyrotherm Ltd 11<br />
Q<br />
Qinhuangdao Taidy Flex-Tech Co. Ltd 596<br />
Quinn Therm Limited 30, 596<br />
R<br />
R & D Sheetmetal Limited 281, 340<br />
R & S Fire & Security Services Limited 596<br />
R Lewis & Co. (UK) Ltd 11<br />
RAMCRO S.p.A 597<br />
Rapidrop Global Limited 597<br />
Recticel Insulation Products / Recticel N.V 30<br />
Red Rose Fire Protection Limited 597<br />
Reliable Fire Sprinkler Limited 597<br />
Retainagroup Limited 501, 504, 598<br />
RGB Integrated Services Limited 598<br />
RGT Fire Protection Limited 598<br />
Richmond Fire Engineers Limited 598<br />
RMD Fire Control Limited 599<br />
Robust UK Limited 599<br />
Rockwool Limited 31, 67, 84, 85, 121, 152, 177,<br />
181, 234, 599<br />
Rolland Sprinklers 599<br />
Ross Fire Protection Limited 599<br />
Rotary Firematic Limited 600<br />
Rotherham CNC Ltd 600<br />
RSM Refko Installations Limited 600<br />
Ruskin Air Management Limited 627<br />
Ruukki Construction Oy 60<br />
Ruukki Polska Sp. z.o.o 32<br />
Ruukki Polska Sp. Z.o.o. 600<br />
S<br />
S.F.S. FIRE SERVICES LIMITED (trading as Hall<br />
& Kay Fire Engineering and Chubb Fire<br />
Mechanical Division) 600<br />
S.F.S. Fire Services Ltd, T/A Hall & Kay Fire<br />
Engineering 601<br />
Safe Partnership 207, 211, 346, 601, 627<br />
SafeGuard Doors, A Division of Adams Rite<br />
Europe Limited 346, 601<br />
Safeguard Security, a trade name of WBH<br />
Industries 437, 601<br />
Safety Hi-Tech Srl 601<br />
Safety Technology International (Europe) Limited<br />
602<br />
Saint-Gobain Weber Limited 519<br />
Salisbury Glass Centre Limited 422, 424, 432, 602<br />
Sanwa Yoshida (JiaXing) Construction Material<br />
Industry Co., Ltd 602<br />
SAPAG Industrial Valves 602<br />
Saudi Factory For Fire Equipment Co. 200, 602<br />
Schlumberger Oilfield UK PLC, Sensor Highway<br />
Limited (Schlumberger, Southhampton) 603<br />
Scotshield Limited 603<br />
Sealed Air Limited 169<br />
Security Blinds Limited 438, 603<br />
Sekisui Aqua Systems Company Limited 603<br />
Select Fire Services Limited 604<br />
Selectaglaze Limited 427, 604<br />
Selectamark Security Systems plc 502, 504, 604<br />
Shaanxi J & R Fire Fighting Co Ltd 604<br />
Shakun Polymers Limited 604<br />
Shellcast Systems Limited 446, 605<br />
ShenZhen CICAM Manufacturing Co Ltd 605<br />
Shurjoint Metals Inc. 605<br />
Siemens plc, Building Technologies, Fire Safety<br />
Division 605<br />
Siemens Switzerland Limited, Building<br />
Technologies Division 606<br />
SigNET AC Limited 606<br />
Simbars (UK) Limited 439, 606<br />
SIP Energy Ltd 526<br />
SMP Security Limited 257, 261, 607<br />
Solent Fire Protection Services Limited 607<br />
Solicom SA 170, 175<br />
Sotech Limited 69, 75, 607<br />
Southern Grille & Gate Limited 607<br />
xiv 20 Nov 2011
INDEX<br />
Spears Manufacturing Company Inc 607<br />
Specialist Panels UK Limited 62, 608<br />
SpeedDeck Building Systems Limited 32<br />
SPIE Fire (A division of SPIE) 608<br />
SPIE Matthew Hall 608<br />
SPP Pumps Limited 609, 627<br />
Sprue Safety Products Ltd 609<br />
Stafford Bridge Doors Limited 347, 416, 450<br />
Stanair Industrial Door Services Limited 211, 610<br />
Stancold plc 62, 610<br />
Static Systems Group Plc 610<br />
Steeltech Systems Limited 610<br />
Steelway Fensecure Limited t/a Steelway<br />
Brickhouse 456<br />
STO AG 610<br />
Sto Ltd 67, 73<br />
Stobich Brandschutz GmbH 201<br />
Stopfire Ltd 12<br />
Stroma Contracting Ltd 12<br />
Sunjüt A.S. 170, 176, 611<br />
Sunray Engineering Limited 201, 207, 360, 417,<br />
611<br />
Superglass Insulation Limited 85<br />
Supra UK Limited 611<br />
Sure Lock Doors Limited 611<br />
Surelock McGill Group 612<br />
SuZhou Primetech Electronics Co Limited 612<br />
SWS UK 439, 447, 449, 453, 612<br />
System Sensor 612<br />
System Sensor de México S.A. de C.V. 613<br />
System Sensor Fire Detectors 613<br />
System Sensor, Honeywell International (I) PVT.<br />
Limited 613<br />
T<br />
Talentum Developments Limited 613<br />
TangoRail Limited 484, 613<br />
Taylor Fire Sprinklers Limited 614<br />
Technocover Limited (incorporating TechnoRail<br />
and Strataform) 203, 282, 376, 419, 450, 458,<br />
468, 496, 614, 628<br />
Terofire Products 614<br />
Thameside Fire Protection Co. Limited 614<br />
The Blinking Lamp Company Ltd 170, 176<br />
The Expanded Metal Company Limited 440, 469,<br />
487, 490<br />
The Reliable Automatic Sprinkler Co., Inc, 614<br />
The Rooflight Company 430, 615<br />
The Safety Letter Box Company Limited 508<br />
The Viking Corporation 615<br />
Thermal Engineering Contracts Ltd 12<br />
Thermotech Fire Protection Limited 615<br />
ThyssenKrupp Steel Europe AG 33<br />
Tindall Engineering Limited 615<br />
Total Polyfilm Limited 171, 615<br />
Tratos Cavi SpA 616<br />
Trellicor (Pty) Limited 441, 449, 616<br />
Trimetals Limited 286, 616<br />
Trimo d.d 34, 39, 63<br />
Twinplast Limited 171, 616<br />
Tyco Building Services Products B.V. 616<br />
Tyco Fire & Building Products 617<br />
Tyco Fire and Integrated Solutions (the trading<br />
company for Tyco Fire and Integrated Solutions<br />
(UK) Limited and Tyco Fire and Integrated<br />
Solutions (Ireland) Limited) 211, 212, 617<br />
Tyco Fire Products Manufacturing Limited 619, 628<br />
Tyco Flow Control (M) Sdn. Bhd. (Tyco Fire<br />
Suppression & Building Products, Malaysia) 619<br />
Tyco Thermal Controls UK Ltd 619<br />
U<br />
UK Fire Safety Limited 619<br />
UK Firewatch Limited 620<br />
Ultra Suppression Systems Limited 620<br />
Univar Speciality Consumables 171<br />
Universal Fixings Limited 620<br />
UTC Fire & Security (Africa) trading as Ziton 620<br />
UTC Fire & Security Americas Corporation, Inc.<br />
621<br />
UTC Fire & Security B.V. 510<br />
UTC Fire & Security Services 621<br />
V<br />
Ventcroft Limited 621<br />
Victaulic Company 621, 622<br />
Viking Plastics 622<br />
Vimpex Limited 622<br />
Vipond Fire Protection Limited 623<br />
Visqueen Building Products 521<br />
Vulcan Tanks Limited 623<br />
W<br />
Wagner Group GmbH 623<br />
Weber, Saint-Gobain Weber Limited 68<br />
WebWayOne Ltd 250<br />
Wienerberger Limited 533<br />
WOPF Befestigungselemente GmbH 623<br />
Wrexham Mineral Cables 623<br />
Writech Industrial Services Limited 624<br />
X<br />
Xi'an System Sensor Electronics Limited 624<br />
Xtratherm Limited 34, 624<br />
Xtratherm UK Limited 624, 628, 630<br />
Y<br />
Yorkon Limited 41<br />
Yorkshire Building Services (Whitwell) Limited 529<br />
Z<br />
Zeta Alarm Systems by GLT Exports Limited 624<br />
Z-Led Limited 533<br />
20 Nov 2011 xv
Part<br />
1<br />
BUILDING PRODUCTS
PART 1: BUILDING PRODUCTS<br />
INTRODUCTION<br />
The specification and installation of building products and systems that provide passive fire protection is a<br />
fundamental aspect of fire safety. Correctly specified and installed passive fire protection products and<br />
systems will deliver a building that resists the incidence of fire to best effect, and in turn provide safety for the<br />
occupants and firefighters, and will reduce the potential for property loss.<br />
In England and Wales, Building Regulations define requirements to ensure the health and safety of those who<br />
occupy or visit buildings. Guidance on how to comply with the Building Regulations in England and Wales is<br />
given in a series of Approved Documents. Approved Document B provides guidance in respect of fire safety.<br />
In other territories, other regulations will apply as laid down by the Authority Having Jurisdiction (AHJ). For<br />
Scotland, Building Regulations guidance is provided by the Domestic and Non-Domestic Technical Handbook<br />
and Northern Ireland Building Regulation guidance is provided by the De<strong>part</strong>ment of Finance (DFP) Technical<br />
Booklet E.<br />
Passive fire protection is a combination of design, assembly and material choice. This will include:<br />
Protection of structural elements<br />
Materials that do not contribute to fire growth<br />
Limited toxicity of combustion products<br />
Walls and floors that provide com<strong>part</strong>ments to resist the spread of fire<br />
Provision of a building envelope to resist fire entering from outside<br />
In addition to careful design and product selection, it is recommended that all products are installed by LPCB<br />
approved contractors who have demonstrated their competence.<br />
Listings in this <strong>section</strong> include:<br />
Products<br />
- Partitions<br />
- Structural steel protection<br />
- Fire stopping/penetration seals<br />
- Products used in transport applications<br />
- Walls and roofs/roofing - the building envelope -<br />
- Protective sheeting<br />
- Temporary buildings for use on site<br />
These products are approved in accordance with various standards, the details of which are given at the front<br />
of each <strong>section</strong>.<br />
Installation contractors<br />
Contractors are approved in accordance with:<br />
LPS 1500: Requirements for the approval and listing of companies installing construction elements used to<br />
provide com<strong>part</strong>mentation in buildings.<br />
LPS 1531: Requirements for the approval and listing of companies installing or applying passive fire<br />
protection products.<br />
2 20 Nov 2011
PART 1: SECTION 1<br />
APPROVED INSTALLERS OF PASSIVE FIRE PROTECTION PRODUCTS<br />
A fundamental aspect of fire safety in buildings is the specification and installation of ‘built in’ or passive fire<br />
protection products and systems. It has long been recognised that the performance of a product can be<br />
severely undermined by poor installation or application leading to failure in the event of a fire. This has led to<br />
the recent development of LPS 1500 Requirements for the LPCB approval and listing of companies installing<br />
construction elements used to provide com<strong>part</strong>mentation in buildings and LPS 1531 Requirements for the<br />
approval and listing of companies installing or applying passive fire protection products. Both these schemes<br />
help to ensure that companies installing passive fire protection :<br />
· Have sufficient training and expertise to install the products or systems using the correct techniques.<br />
· Use products where it can be demonstrated that they will meet the required fire performance.<br />
· Have access to up to date installation instructions for the installed systems.<br />
· Carry out and record in process inspection checks prior to, during and after the product or system<br />
installation.<br />
· Issue LPCB Certificates of Conformity for each installation.<br />
LPS 1500 was developed specifically for companies installing fire resisting com<strong>part</strong>mentation systems<br />
approved by the LPCB to LPS 1208.<br />
LPS 1531 is an installer scheme that covers all the major product areas of passive fire protection.<br />
20 Nov 2011 3
PART 1: SECTION 1.1<br />
LPS 1500 APPROVED INSTALLER OF FIRE RESISTING COMPARTMENTATION SYSTEM<br />
The companies listed in this <strong>section</strong> are approved installers of fire resisting com<strong>part</strong>mentation systems<br />
approved by LPCB to LPS 1208.<br />
LPS 1208 Approved products for use in the following elements of construction may be installed under this<br />
scheme.<br />
Loadbearing com<strong>part</strong>ment walls and <strong>part</strong>itions<br />
Non-load bearing com<strong>part</strong>ment walls and <strong>part</strong>itions<br />
External walls<br />
Curtain walls<br />
Cavity barriers<br />
Roofs where fire resistance is required (loadbearing and non-loadbearing)<br />
Loadbearing com<strong>part</strong>ment floors<br />
Insulated panels used for enclosing production and storage areas in food factories.<br />
G & A Fire Protection Ltd<br />
Helions Bumpstead Road, Haverhill, Suffolk CB9 7AA, United Kingdom<br />
Tel: +44 (0) 1440 714650 • Fax: +44 (0) 1440 713371<br />
E-mail: info@ga-group.com • Website: www.ga-group.com<br />
Certificate No. 889PIb to LPS 1500 Issue 2<br />
Installer of fire resisting com<strong>part</strong>mentation systems to LPS 1500<br />
MITIE Property Services Limited - Midlands<br />
2 Colwick Quays Business Park, Private Road No.2, Colwick, Nottingham NG4 2JY, United Kingdom<br />
Tel: 0115 940 1770 • Fax: 0115 940 2232<br />
E-mail: malcolm.williams@mitie.com • Website: www.mitie.com<br />
Northern Office<br />
MITIE Property Services Limited, Meiklewood Gate, 35 Meiklewood Road, Glasgow G51 4GB, United<br />
Kingdom<br />
E-mail: Steven.Elliot@mitie.co.uk • Website: www.mitie.com<br />
Certificate No. 769a to LPS 1500: Issue 2.0<br />
Installer of Fire Resisting Com<strong>part</strong>mentation Systems to LPS 1500<br />
P&M Group Ltd trading as ISD<br />
Unit A, 125 Business Park, Llanthony Road, Gloucester, Glos GL2 5JQ, United Kingdom<br />
Tel: +44 (0) 1452 520649 • Fax: +44 (0) 1452 301910<br />
E-mail: sales@isdcoldstores.co.uk • Website: www.isdcoldstores.co.uk<br />
Certificate No. 1008PIa to LPS 1500 Issue 2.0<br />
Installer of fire resisting com<strong>part</strong>mentation systems to LPS 1500<br />
4 20 Nov 2011
PART 1: SECTION 1.2<br />
LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS<br />
The companies listed in this <strong>section</strong> are approved to install passive fire protection products for the Appendix<br />
areas indicated in their entry.<br />
Appendix areas:<br />
1. Penetration, cavity barrier and linear gap seals<br />
2. Fire rated board and cladding to structural elements<br />
3. Intumescent coatings to structural elements<br />
4. Fire rated spray materials<br />
5. Fire rated ductwork systems<br />
6. Fire resisting dampers<br />
7. Fire resistant com<strong>part</strong>ment wall systems<br />
8. Offsite application of intumescent coatings to structural elements<br />
Abbey Thermal Insulation Ltd<br />
23-24 Riverside House, Lower Southend Road, Wickford, Essex SS11 8BB, United Kingdom<br />
Tel: +44 (0) 1268 572116 • Fax: +44 (0) 1268 572117<br />
E-mail: robert.stubbs@abbeythermal.com<br />
Certificate No. 1014PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barrier and linear gap seals.<br />
Appendix 2 - Fire rated board and cladding to structural elements.<br />
Appendix 5 - Fire rated ductwork systems.<br />
Avert Fire (UK) Ltd<br />
P O Box 248, Dawes lane, Scunthorpe DN16 1DW, United Kingdom<br />
Tel: +44 (0)1724 853712 • Fax: +44 (0)1724 278848<br />
E-mail: admin@avertfire.co.uk; kevin@avertfire.co.uk • Website: www.avertfire.co.uk<br />
Certificate No. 850PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals.<br />
Bryen & Langley Limited<br />
48-60 Footscray Road, Eltham, London SE9 2SU, United Kingdom<br />
Tel: +44 (0)20 8850 7775 • Fax: +44 (0)20 8850 6772<br />
E-mail: AEscudier@bryen-langley • Website: www.bryen-langley.com<br />
Certificate No. 897Pl to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals.<br />
20 Nov 2011 5
PART 1: SECTION 1.2<br />
LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS<br />
Checkmate Fire Solutions Ltd<br />
Head Office:<br />
Royd House, 11 Birds Royd Lane, Brighouse, West Yorkshire HD6 1LQ, United Kingdom<br />
Tel: 01484 721154 • Fax: 01484 723152<br />
Southern Office:<br />
Unit 1, Woodgates Farm, Woodgates End, Dunmow, Essex CM6 2BN, United Kingdom<br />
Tel: +44 (0)1279 850021 • Fax: +44 (0)1279 850261<br />
E-mail: info@checkmatefire.com • Website: www.checkmatefire.com<br />
Certificate No. 860PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals<br />
Appendix 2 - Fire rated board and cladding to structural elements<br />
Appendix 3 - Intumescent coatings to structural elements<br />
Cleshar Contract Services Ltd<br />
Heather Park House, North Circular road, Stonebridge, London NW10 7NN, United Kingdom<br />
Tel: +44 (0) 20 8733 8888 • Fax: +44 (0) 20 8733 8899<br />
E-mail: chris.carter@cleshar.co.uk / jeremy.ilott@cleshar.co.uk • Website: www.cleshar.co.uk<br />
Certificate No. 944PI to LPS 1531<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals<br />
Corecut Fire Protection (a division of Corecut Limited)<br />
Bankhead, Broxburn, West Lothian EH52 6PP, United Kingdom<br />
Tel: +44 (0) 1506 854710 • Fax: +44 (0) 1506 853068<br />
E-mail: office@courecut.co.uk • Website: www.corecut.co.uk<br />
Certificate No. 1028PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals.<br />
Appendix 3 - Intumescent coatings to structural elements.<br />
CVD Fire Protection Ltd<br />
Unit 1A, East End Farm Estate, Lanark Road, Carstairs, Lanarkshire ML11 8QG, United Kingdom<br />
Tel: +44 (0) 845 450 1601 • Fax: +44 (0) 845 450 1602<br />
E-mail: info@cvdfire.co.uk • Website: www.cvdfire.co.uk<br />
Certificate No. 1009PI to LPS 1531 Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals<br />
6 20 Nov 2011
PART 1: SECTION 1.2<br />
LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS<br />
Appendix 2 - Fire rated board and cladding to structural elements<br />
Appendix 3 - Intumescent coatings to structural elements<br />
David Tyrrell T/A Nene Valley Acoustics<br />
2a New Street, Irthlingborough, Northamptonshire NN9 5UG, United Kingdom<br />
Tel: +44 (0) 1933 650650 • Fax: +44 (0) 1933 704830<br />
E-mail: David_Tyrrell@btconnect.com<br />
Certificate No. 1021PI to LPS 1531 Issue 1<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barrier and linear gap seals.<br />
E&S Heating & Ventilation Ltd<br />
Diplocks Way, Hailsham, East Sussex BN27 3JF, United Kingdom<br />
Tel: +44 (0) 1323 845492 • Fax: +44 (0) 1323 440577<br />
E-mail: emmacollins@esgroup.co.uk • Website: www.esgroup.co.uk<br />
Certificate No. 1013PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 5 - Fire rated ductwork systems.<br />
Fendor Limited<br />
Heworth House, William Street, Felling, Gateshead NE10 0JP, United Kingdom<br />
Tel: +44 (0)191 438 3222 • Fax: +44 (0)191 438 1686<br />
E-mail: av@fendor.co.uk • Website: www.fendor.co.uk<br />
Certificate No. 712c to LPS 1531 Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals.<br />
Fire Protection Limited<br />
Flamebar House, South Road, Templefields, Harlow, Essex CM20 2AR, United Kingdom<br />
Tel: +44 (0)1279 634 230 • Fax: +44 (0)1279 634 231<br />
E-mail: info@fireprotection.co.uk • Website: www.fireprotection.co.uk<br />
Certificate No. 277b to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope:<br />
Appendix 5 - Fire rated ductwork systems.<br />
20 Nov 2011 7
PART 1: SECTION 1.2<br />
LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS<br />
Fire Protection Solutions Ltd<br />
1-3 Highway Point, 239 Torrington Avenue, Coventry CV4 9AP, United Kingdom<br />
Tel: +44 (0) 845 0538989 • Fax: +44 (0) 2476 465568<br />
E-mail: fpcltd@btconnect.com • Website: www.firecontractor.co.uk<br />
Certificate No. 1015PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barrier and linear gap seals.<br />
Appendix 2 - Fire rated board and cladding to structural elements.<br />
Appendix 3 - Intumescent coatings to structural elements.<br />
Flameshield Products Limited (Incorporating Flameshield Limited)<br />
4 The Limes, Ingatestone, Essex CM4 0BE, United Kingdom<br />
Tel: +44 (0)1277 352202 • Fax: +44 (0)1277 355419<br />
E-mail: info@flameshield.org • Website: www.flameshield.org<br />
Certificate No. 785b to LPS 1531 Issue 1<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 5 - Fire rated ductwork systems.<br />
G & A Fire Protection Ltd<br />
Helions Bumpstead Road, Haverhill, Suffolk CB9 7AA, United Kingdom<br />
Tel: +44 (0) 1440 714650 • Fax: +44 (0) 1440 713371<br />
E-mail: info@ga-group.com • Website: www.ga-group.com<br />
Certificate No. 889PIa to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals<br />
Appendix 2 - Fire rated board and cladding to structural elements<br />
Appendix 3 - Intumesent coatings to structure elements<br />
Gardner & Co (Kent) Ltd<br />
1 - 5 Bermondsey Street, London SE1 2ER, United Kingdom<br />
Tel: 020 7403 5894 • Fax: 020 7378 0316<br />
E-mail: enquiries@gardnerco.net • Website: www.gardnerco.net<br />
Certificate No. 1040PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 5 - Fire rated ductwork systems.<br />
8 20 Nov 2011
PART 1: SECTION 1.2<br />
LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS<br />
Giffen Group<br />
Lyon Way, St Albans, Hertforshire AL4 0LQ, United Kingdom<br />
Tel: +44 (0)1727 869126<br />
E-mail: dan.bliss@giffengroup.co.uk • Website: www.giffengroup.co.uk<br />
Certificate No. 979PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity, barriers and linear gap seals.<br />
Gunfire (Gunite Eastern Limited)<br />
Endeavour House, Compass Point, St Ives, Cambridgeshire PE27 5JL, United Kingdom<br />
Tel: +44 (0)1480 466880 • Fax: +44 (0)1480 308999<br />
E-mail: admin@gunite.co.uk • Website: www.gunite.co.uk<br />
Certificate No. 848PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals.<br />
Appendix 3 - Intumescent coatings to structural elements.<br />
H&S Decorating Specialists Ltd<br />
1 Wellesley Avenue, Richings Park, Iver, Bucks SL0 9AU, United Kingdom<br />
Tel: +44 (0)1753 654123 • Fax: +44 (0)1753 654345<br />
E-mail: info@hsgroup.co.uk • Website: www.hsgroup.co.uk<br />
Certificate No. 956PI to LPS 1531 Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 3 - Intumescent coatings to structural elements<br />
Hillmoore Fire Protection Ltd<br />
Unit 17-18 Woodlands Farm, Spring Lane, Cookham Dean, Berkshire SL6 9PN, United Kingdom<br />
Tel: +44 (0)1628 890122 • Fax: +44 (0)1628 478543<br />
E-mail: info@ hillmoorefire.co.uk • Website: www.hillmoorefireprotection.co.uk<br />
Certificate No. 849PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barrier and linear gap seals.<br />
Appendix 7 - Fire resistanct com<strong>part</strong>ment wall system.<br />
20 Nov 2011 9
PART 1: SECTION 1.2<br />
LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS<br />
M J Quinn Integrated Services Ltd<br />
119 Farringdon Road, London EC1R 3DA, United Kingdom<br />
Tel: 0207 239 8750 • Fax: 0207 239 8751<br />
E-mail: BOHara@mjquinn.co.uk • Website: www.mjquinn.co.uk<br />
Certificate No. 1041PI to LPS 1531 Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barrier and linear gap seals.<br />
Mansell Construction Services LTD<br />
Rink Road, Ryde, Isle of Wight PO33 1LP, United Kingdom<br />
Tel: +44 (0) 1983 563668 • Fax: +44 (0) 1983 615600<br />
E-mail: kbloomfield@mansell.plc.uk • Website: www.mansell.plc.uk<br />
Certificate No. 1017PI to LPS 1531 Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barrier and linear gap seals.<br />
Appendix 7 - Fire resistant com<strong>part</strong>ment wall systems.<br />
Map Ventilation Limited<br />
Hanwiz House, Milner Way, Ossett, Wakefield WF5 9JG, United Kingdom<br />
Tel: 01924 278175 • Fax: 01924 278126<br />
E-mail: info@mapventilation.co.uk • Website: www.mapventilation.co.uk<br />
Certificate No. 1065PI to LPS 1531 Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 5 - Fire rated ductwork systems<br />
Midlands Fire Ltd<br />
Unit D8 The Ropewalk Industrial Estate, The Ropewalk, Ilkeston, Derbyshire DE7 5HX, United Kingdom<br />
Tel: +44( 0) 115 932 9548 • Fax: +44 (0) 845 009 5727<br />
E-mail: info@midlandsfire.co.uk • Website: www.midlandsfire.co.uk<br />
Certificate No. 887PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope:<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals<br />
Appendix 7 - Fire resistant com<strong>part</strong>ment wall systems.<br />
10 20 Nov 2011
PART 1: SECTION 1.2<br />
LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS<br />
O'Mahony Contractors Ltd<br />
60 Middle Road, Higher Denham, Buckinghamshire UB9 5EQ, United Kingdom<br />
Tel: 01895 833553 • Fax: 01895 835003<br />
E-mail: gary@omahonycontractors.com • Website: www.omahonycontractors.com<br />
Certificate No. 914PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals<br />
Appendix 2 - Fire rated board and cladding to structural elements<br />
P&M Group Ltd trading as ISD<br />
Unit A, 125 Business Park, Llanthony Road, Gloucester, Glos GL2 5JQ, United Kingdom<br />
Tel: +44 (0) 1452 520649 • Fax: +44 (0) 1452 301910<br />
E-mail: sales@isdcoldstores.co.uk • Website: www.isdcoldstores.co.uk<br />
Certificate No. 1008PIb to LPS 1531 Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals.<br />
Appendix 2 - Fire rated board and cladding to structural elements.<br />
Appendix 7 - Fire resistant com<strong>part</strong>ment wall systems.<br />
Pyrotherm Ltd<br />
8 Jensen Court, Astmoor Industrial Estate, Runcorn, Cheshire WA7 1SQ, United Kingdom<br />
Tel: +44 (0)1928 565641 • Fax: +44 (0) 1928 565648<br />
E-mail: paulbusow@pyrotherm.co.uk • Website: www.pyrotherm.co.uk<br />
Certificate No. 1007PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals.<br />
Appendix 2 - Fire rated board and cladding to structural elements.<br />
Appendix 3 - Intumescent coatings to structural elements.<br />
R Lewis & Co. (UK) Ltd<br />
Unit 7 and 8, Parklands Industrial Estate, East Moors Road, Cardiff CF24 5JP, United Kingdom<br />
Tel: +44 (0) 2920 215716 • Fax: +44 (0) 2920 406205<br />
E-mail: chris@rlewisandcoukltd.com • Website: www.rlewisandcoukltd.com<br />
Certificate No. 1006PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals.<br />
Appendix 2 - Fire rated board and cladding to structural elements.<br />
Appendix 3 - Intumescent coatings to structural elements.<br />
20 Nov 2011 11
PART 1: SECTION 1.2<br />
LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS<br />
Stopfire Ltd<br />
Units 22, 23, 24 & 32 Dryden Road, Loanhead, Midlothian EH20 9LZ, United Kingdom<br />
Tel: +44(0)131 448 0555 • Fax: +44(0)131 448 0556<br />
E-mail: mail@stopfire.net • Website: www.stopfireltd.com<br />
Certificate No. 862PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals<br />
Appendix 2 - Fire rated board and cladding to structural elements<br />
Appendix 3 - Intumescent coatings to structural elements<br />
Stroma Contracting Ltd<br />
Stroma House, Unit 4, Pioneer Way, Castleford WF10 5QU, United Kingdom<br />
Tel: +44 (0)845 621 1111 • Fax: +44(0)845 621 1112<br />
E-mail: contracting@stroma.com • Website: www.stroma.com<br />
Certificate No. 967PI to LPS 1531: Issue 1<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barrier and linear gap seals.<br />
Appendix 2 - Fire rated board and cladding to structural elements.<br />
Appendix 3 - Intumescent coatings to structure elements.<br />
Thermal Engineering Contracts Ltd<br />
38 Whitehouse Street, , Leeds LS10 1AD, United Kingdom<br />
Tel: +44(0) 1132 430254 • Fax: +44(0) 5603 430284<br />
E-mail: info@tecl.uk.com • Website: www.tecl.uk.com<br />
Certificate No. 963PI to LPS 1531: Issue 1.0<br />
Company assessed and approved for installation of passive fire protection products under the following scope.<br />
Appendix 1 - Penetration, cavity barriers and linear gap seals.<br />
12 20 Nov 2011
PART 1: SECTION 2<br />
CONSTRUCTION PRODUCT SYSTEMS (BUILDING ENVELOPE, ROOFING & PARTITIONS)<br />
This <strong>section</strong> includes the reaction to fire and fire resistance approval schemes for construction systems<br />
including building envelope, roofing and <strong>part</strong>itions.<br />
This <strong>section</strong> includes:<br />
Section 2.1<br />
Section 2.1.1<br />
Section 2.1.2<br />
Section 2.1.3<br />
Section 2.1.4<br />
Section <strong>2.2</strong><br />
Section 2.3<br />
Section 2.3.1<br />
Section 2.3.2<br />
Section 2.4<br />
Section 2.4.1<br />
Section 2.4.2<br />
Section 2.5<br />
Section 2.5.1<br />
Section 2.5.2<br />
Section 2.6<br />
LPS 1181 Series<br />
LPS 1181 Lining materials<br />
LPS 1181-1 Cladding products used for the external envelope of buildings.<br />
LPS 1181-2 Sandwich panels or built-up panel systems used internally in a building.<br />
LPS 1181-3 (Draft) Cladding used in POD construction<br />
LPS 1208 Composite construction elements<br />
LPS 1581 External cladding systems on a masonry substrate<br />
LPS 1581 External thermal insulated cladding (ETICS)<br />
LPS 1581 Rain screen cladding systems (RSC)<br />
LPS 1582 External cladding systems supported by a structural steelwork frame<br />
LPS 1582 External thermal insulated cladding (ETICS)<br />
LPS 1582 Rain screen cladding system (RSC)<br />
Roofing products<br />
Protection against fire outside of the building<br />
Protection against fire from inside the building<br />
Reaction to Fire (RTF) classifications for Materials and Products<br />
20 Nov 2011 13
PART 1: SECTION 2.1<br />
LPS 1181 SERIES<br />
The LPS 1181 series of fire growth standards cover the requirements for LPCB approval and listing of<br />
construction product systems. These standards evaluate the fire performance of sandwich panels, built-up<br />
cladding systems and other construction product systems to ensure they will not significantly contribute to fire<br />
growth in their defined end use applications as detailed in the following listings.<br />
The use and application of the LPS 1181 standards are as follows:<br />
<br />
<br />
<br />
<br />
<br />
The LPS 1181 series of standards cover sandwich panels and built up cladding systems including<br />
jointing and fixing methods, sealants, gaskets and flashings.<br />
The LPS 1181 series of standards are used by the insurance industry for property protection<br />
purposes.<br />
The requirements of the Building Regulations are not addressed by the LPS 1181 series of<br />
standards.<br />
The Building Regulations define the life safety requirements for buildings.<br />
Approved Document B (produced by Communities and Local Government) provides guidance on<br />
meeting the requirements of the Building Regulations for fire safety and utilises the test data from the<br />
applicable BS 476 series and/or the BS EN 13501 series of standards.<br />
The LPS 1181 series currently consists of the following <strong>part</strong>s:<br />
LPS 1181: Part 1 Requirements and tests for built-up cladding and sandwich panel systems for use as the<br />
external envelope of buildings - See Section 2.1.2<br />
LPS 1181: Part 2 Requirements and tests for sandwich panels and built-up systems for use as internal<br />
constructions in buildings - See Section 2.1.3<br />
LPS 1181: Part 3 (Draft) Requirements and tests for factory produced room modules (PODS) and building<br />
system modules - See Section 2.1.4<br />
Within the LPS 1181 series of standards there are a number of classifications and these are summarised as<br />
follows:<br />
<br />
<br />
Cladding systems used for the external envelope of buildings are tested to LPS 1181 <strong>part</strong> 1. Those<br />
products that pass the test are graded into 2 classes: -<br />
o<br />
o<br />
Grade EXT-A** - A product that satisfies both the requirements of LPS 1181: Part 1 and also<br />
demonstrates fire resistance through a fire resistance test as specified in LPS 1208 (see<br />
<strong>section</strong> <strong>2.2</strong>). Such products meet the requirements for separating elements used for<br />
com<strong>part</strong>mentation. (** represents in minutes, the LPCB grading of insulation achieved during<br />
the fire resistance tests).<br />
EXT B - A product that satisfies the requirements of LPS 1181 <strong>part</strong> 1 only.<br />
Sandwich panels and built-up systems used internally in a building for the construction of cold stores,<br />
factory clean rooms, space separation etc are tested in the large-scale test in LPS 1181 <strong>part</strong> 2. Those<br />
products that pass the test are graded into 3 classes: -<br />
o INT 1 - A product that achieves a minimum fire resistance performance of integrity = 60<br />
minutes and insulation = 60 minutes and passes the requirements of the LPS 1181 <strong>part</strong> 2<br />
large-scale test with an enhanced thermal exposure.<br />
o INT 2 - A product that achieves a minimum fire resistance performance of integrity = 30<br />
minutes and insulation = 30 minutes and passes the requirements of LPS 1181 <strong>part</strong> 2 largescale<br />
test with a crib ignition source.<br />
o<br />
INT 3 - A product that passes the requirements of LPS 1181 <strong>part</strong> 2 large-scale test with a crib<br />
ignition source but has no fire resistance.<br />
14 20 Nov 2011
PART 1: SECTION 2.1<br />
LPS 1181 SERIES<br />
A guide to example applications with the potential inception risks and associated LPS 1181 classes (<strong>part</strong> 1<br />
and 2) can be found in appendices 1, 3 and 4 of “Technical briefing: Fire performance of sandwich panel<br />
systems” published by the Association of British Insurers in May 2003.<br />
It is the responsibility of end users, whether they be specifiers, regulators, insurers, architects etc, to satisfy<br />
themselves that any performance claims made by the manufacturers are valid by reference to a relevant<br />
certificate, listing and/or test reports and that the product satisfies all the necessary regulatory and design<br />
requirements. This responsibility also extends to ensuring that the systems are installed correctly and in<br />
accordance with the manufacturer’s instructions.<br />
20 Nov 2011 15
PART 1: SECTION 2.1.1<br />
LPS 1181 LINING MATERIALS<br />
The products listed in this <strong>section</strong> are intended to provide an additional, separate internal lining material to<br />
improve the thermal insulation of light steel or concrete industrial, agricultural and storage buildings. The listed<br />
products are often installed during the refurbishment of such buildings.<br />
These products have been tested to ensure that they do not significantly contribute to a developing fire. The<br />
fire properties of these lining materials have been determined from the relevant criteria of the series of fire<br />
growth tests described in the LPS 1181 series of standards.<br />
The lining materials are designed to be installed where the fire risk assessment of the building indicates a low<br />
to medium risk. Where the fire risk assessment of the building indicates a high fire risk, then products<br />
approved to LPS 1181:Part 1 or Part 2, as listed in Sections 2.1.2 and 2.1.3 should be used.<br />
16 20 Nov 2011
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
LPS 1181: Part 1 Requirements and tests for built-up cladding and sandwich panel systems for use as the<br />
external envelope of buildings.<br />
This standard determines the contribution to fire growth of built-up cladding and sandwich panel systems used<br />
as the external envelope of buildings.<br />
The test is a large scale test comprising setting fire to an open-ended enclosure, supported on a steel frame,<br />
from the sandwich panels or built-up cladding system. It evaluates the panels, the jointing methods and the<br />
supporting system including fixings, which gives an assessment of the true fire performance of the system<br />
which cannot be determined from traditional small scale reaction to fire tests, such as surface spread of flame<br />
or fire propagation tests.<br />
Products that have passed the test and have achieved LPCB approval are graded under the following<br />
designations:-<br />
Grade EXT-A** - A product that satisfies both the requirements of LPS 1181: Part 1 and also demonstrates<br />
fire resistance through a fire resistance test as specified in LPS 1208 (see <strong>section</strong> <strong>2.2</strong>). Such products meet<br />
the requirements for separating elements used for com<strong>part</strong>mentation. (** represents in minutes, the LPCB<br />
grading of insulation achieved during the fire resistance tests).<br />
Grade EXT-B - A product that satisfies the requirements of LPS 1181: Part 1 only.<br />
A Steadman & Son<br />
(a division of SIG Trading Ltd), Warnell, Welton, Carlisle, Cumbria CA5 7HH, United Kingdom<br />
Tel: +44 (0)16974 78277 • Fax: +44 (0)16974 78530<br />
E-mail: info@steadmans.co.uk • Website: www.steadmans.co.uk<br />
Certificate No: 635a to LPS 1181:Part 1<br />
Composite Wall and Ceiling Panels<br />
Product Name Specification<br />
Thickness (mm)<br />
Specification Wall<br />
panel orientation (H/V)<br />
(note 1)<br />
AS35/1000 PIR 40, 60, 80, 100 &<br />
(ceiling panel)<br />
AS35/1000 PIR<br />
(wall panel)<br />
Fire Resistance<br />
Integrity/Insulation<br />
LPS<br />
1181-1<br />
Grade<br />
Core<br />
Material<br />
- - EXT-B PIR 635a/04<br />
120<br />
40 V - EXT-B PIR<br />
100 & 120 V 120/30 EXT-A30 PIR 635a/05<br />
60, 80, 100 & 120 V 120/15 EXT-A15 PIR<br />
Cert.<br />
No.<br />
Notes:<br />
1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
2. LPCB Ref 635a/04 and 635a/05 panels require external overlap stitching using 6.3mm diameter x 22mm steel screws at 300mm centres<br />
for wall panels and 450mm centres for ceiling panels.<br />
3. LPCB Ref 635a/04 and 635a/05, wall and/or ceiling side lap joints require a sealant tape (HP500 GCA butyl tape) to be applied during the<br />
installation.<br />
4. LPCB Ref 635a/05 maximum unsupported span shall be limited to 1.5m between supports.<br />
ArcelorMittal Construction Belgium NV<br />
Lammerdries 8, Industrieterrein Geel West Z4, B-2440 Geel, Belgium<br />
Tel: +32 14563943 • Fax: +32 14563952<br />
E-mail: eric.mees@arcelormittal.com • Website: www.arclad.be<br />
Certificate No: 939a to LPS 1181: Part 1<br />
20 Nov 2011 17
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Composite Panels<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
(min)<br />
Integrity<br />
Fire Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
AMW 1000 (wall panel) 60, 80 & 100 - - EXT-<br />
B<br />
AMRW 1000 (wall & roof 40, 50, 60,<br />
- - EXTpanel)<br />
80 & 100<br />
B<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
PIR 939a/01<br />
PIR 939a/02<br />
1. LPCB Ref. 939a/01 & 939a/02 Wall panels can be laid either vertically or horizontally.<br />
2. LPCB Ref. 939a/02 External side lap joints to be stitched at 300mm centres using Fastovis 5 6,3 x 35mm screws.<br />
Brucha Ges.m.b.H<br />
Rusterstrasse 33, A-3451 Michelhausen, Michelhausen, Austria<br />
Tel: +43 (2275) 5878 1800 • Fax: +43 (2275) 5875 1804<br />
E-mail: office@brucha.at • Website: www.brucha.com<br />
Certificate No: 900a to LPS1181: Part 1: Issue 1.1<br />
Product Name<br />
WP-F (wall and roof<br />
panels)<br />
Specification<br />
Thickness (mm)<br />
60, 80, 100, 120,<br />
150<br />
& 200<br />
Fire Resistance<br />
(min)<br />
Integrity<br />
Fire Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
- - EXT-<br />
B<br />
Core<br />
Material<br />
Mineral<br />
Wool<br />
Cert.<br />
No.<br />
900a/01<br />
Notes:<br />
1. LPCB Ref. 900a/01 wall panels to be laid with long joint in vertical orientation only.<br />
CA Group Limited<br />
Evenwood Industrial Estate, Copeland Road, Evenwood, Co. Durham DL14 9SF, United Kingdom<br />
Tel: +44 (0)1388 834242 • Fax: +44(0)1388 834881<br />
E-mail: help@cagroup.ltd.uk • Website: www.cagroup.ltd.uk<br />
Certificate No: 443a to LPS 1181 Part 1: Issue 1<br />
Product Name<br />
Specification<br />
System<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Cert. No.<br />
Twin-Therm Fire Wall 95 - 200 240 30 EXT-A30 Mineral wool 443a/02<br />
Twin-Therm Wall 50 - 220 - - EXT-B Glass wool 443a/03<br />
Twin-Therm Roof 50 - 220 - - EXT-B Glass wool 443a/04<br />
Plano-Therm Wall 147 - 281 EXT-B Glass wool 443a/05<br />
River-Therm Roof 218 - 263 EXT-B Glass wool 443a/06<br />
SolarWall Wall 324 - 543 EXT-B Glass wool 443a/07<br />
Plano-Therm Fire Wall 173 - 218 120 30 EXT-A30 Mineral wool 443a/08<br />
SolarWall Fire Wall 324 - 543 240 30 EXT-A30 Mineral wool 443a/09<br />
Notes:<br />
1. LPCB Ref. 443a/02, 443a/03, 443a/05, 443a/07, 443a/08 and 443a/09, Wall Panels can be laid vertically or horizontally. For full<br />
details contact C A Group<br />
2. LPCB Ref. 443a/02, 443a/03, 443a/05, 443a/07, 443a/08 and 443a/09, The base of wall systems must be supported.<br />
3. LPCB Ref. 443a/02, Twin-Therm Fire Wall: external sheet may be CA 32 1000R, CA 32 1000W, CA 40 1000RW, CA 45 1000W or<br />
CA ARC 50 930.<br />
4. LPCB Ref. 443a/03, Twin-Therm Wall: external sheet may be CA 32 1000R, CA 32 1000W, CA 40 1000RW, CA 45 1000W or CA<br />
ARC<br />
5. LPCB Ref. 443a/04, Twin-Therm Roof: external sheet may be CA 32 1000R<br />
6. All systems, Internal sheeting normally CA LT 17 1000S. Twin-Therm roof may be lined with CA 32 1000RL.<br />
18 20 Nov 2011
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Corus Panels and Profiles<br />
Shotton Works, Flintshire CH5 2NH, United Kingdom<br />
Tel: +44 (0)1684 856600 • Fax: +44 (0)1684 856601<br />
E-mail: sales@coruspanelsandprofiles.co.uk • Website: www.coruspanelsandprofiles.com<br />
Certificate No: 460a to LPS 1181: Part 1 Issue 1<br />
Product Name<br />
System<br />
Specification<br />
Thickness<br />
(mm)<br />
Wall panel<br />
orientation<br />
(H/V)<br />
(note 1)<br />
Fire Resistance<br />
(minutes)<br />
Integrity/Insulation<br />
Grade<br />
Core<br />
material<br />
Trimapanel wall panel 70 H 240/16 EXT- PIR* 460a/13<br />
A15<br />
90 H 240/27 EXT- PIR*<br />
A30<br />
70 and 90 V or H - EXT-B PIR*<br />
Built up wall (System W1) 160-220 V 240/30 EXT- Mineral wool 460a/14<br />
A30<br />
80-220 V 240/15 EXT- Mineral wool<br />
A15<br />
Built up roof (System R1) 60-220 - - EXT-B Mineral wool 460a/15<br />
Built up roof (System R2) 60-220 - - EXT-B Mineral wool 460a/16<br />
Trinsul wall and roof system 90 - - EXT-B Mineral wool 460a/19<br />
- - 240/60 EXT- Mineral wool<br />
A60<br />
Structural Liner Tray Roof<br />
190 - - EXT-B PIR* / Mineral 460a/20<br />
system<br />
wool<br />
Structural Liner Tray Wall<br />
system<br />
170 V - EXT-B PIR* / Mineral<br />
wool<br />
170 V 120/15 EXT-<br />
A15<br />
PIR* / Mineral<br />
wool<br />
Structural Flat Metal Roof<br />
50-200 - - EXT-B Mineral wool 460a/21<br />
Deck<br />
Stratatherm façade 80-150 H - EXT-B Mineral wool 460a/22<br />
Built up acoustic wall and roof<br />
175 V - EXT- Mineral wool 460a/23<br />
systems<br />
A15<br />
Built up acoustic wall system 175 V 240/15 EXT- Mineral wool<br />
A15<br />
Hybrid Acoustic roof system 120 - - EXT-B PIR* / Mineral 460a/24<br />
wool<br />
Hybrid Acoustic wall system 100 V 240/15 EXT-<br />
A15<br />
PIR* / Mineral<br />
wool<br />
Trisomet 333 (roof and wall 40, 60, 80, 100 and H or V - EXT-B PIR* 460a/26<br />
panel)<br />
120<br />
Trisomet 333 (wall panel) 60, 80, 100 and 120 V 240/25 EXT-<br />
A15<br />
PIR* 460a/27<br />
Cert.<br />
No.<br />
Notes:<br />
1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
2. The PIR core materials marked * are both CFC and HCFC Free and are stated to be Low Global Warming Potential (GWP).<br />
3. LPCB Ref 460a/13, Trimapanel wall panels having a grade EXT-A are to be stitched on the internal face with SFS Intec IR2 - 4.8 x 60<br />
(70mm thick panel), or SFS Intec IR2 - 4.8 x 80 (90mm thick panel) screws or similar at maximum 250mm centres.<br />
4. LPCB Ref 460a/19 Trinsul wall system outer liner 0.55mm steel stitched at minimum 600mm centres, internal liner 0.4mm steel.<br />
5. LPCB Ref 460a/20 Structural Liner Tray system requires the liner tray joints to be stitched at minimum 450mm centres.<br />
6. LPCB Ref 460a/21 Structural Flat Metal roof deck steel profile liner D19 - D35 require no side lap stitching, steel profile liner D46 -<br />
D159 require side lap stitching min. 450mm c/c and steel profile liner D210 require side lap stitching min 350mm c/c.<br />
7. LPCB Ref 460a/26 Trisomet 333 wall panels can be laid with the long joints in the vertical orientation stitched or unstitched, or in the<br />
horizontal orientation with the overlap joint stitched at maximum 600mm centres.<br />
8. LPCB Ref 460a/26 Trisomet 333 roof panels are to be secured to each purlin with 3 fixings, the perimeter of the roof system is to be<br />
secured to the frame support through the panel edge at 300mm centres.<br />
9. LPCB Ref 460a/27 Trisomet 333 wall panels are to be stitched at maximum 300mm centres with SL2-T-A14-4.8x20 self tapping steel<br />
screws or similar.<br />
20 Nov 2011 19
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Eurobond Laminates Limited & Eurobond Doors Limited<br />
Wentloog Corporate Park, Wentloog, Cardiff CF3 2ER, United Kingdom<br />
Tel: + 44 (0)2920 776677 • Fax: + 44 (0)2920 369161<br />
E-mail: sales@eurobond.co.uk • Website: www.eurobond.co.uk<br />
Product Name<br />
Europanel Extra<br />
(wall panel)<br />
Europanel Lite (wall<br />
panel)<br />
Europanel Premier<br />
(wall panel)<br />
Rockspan Extra<br />
(wall panel)<br />
Rockspan Lite (wall<br />
panel)<br />
Thickness<br />
(mm)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Fire Resistance<br />
Integrity/Insulation<br />
(minutes)<br />
LPS1181-1<br />
Grade<br />
Core<br />
Material<br />
75 V or H 60/60 EXT-A60 Mineral<br />
fibre<br />
100 V or H 60/60 EXT-A60 Mineral<br />
fibre<br />
125 V or H 90/90 EXT-A90 Mineral<br />
fibre<br />
150 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
175 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
200 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
75, 100, 125, V or H - EXT-B Mineral<br />
150, 175 & 200<br />
fibre<br />
75 V or H 60/30 EXT-A30 Mineral<br />
fibre<br />
100 V or H 60/30 EXT-A30 Mineral<br />
fibre<br />
125 V or H 90/60 EXT-A60 Mineral<br />
fibre<br />
150 V or H 120/90 EXT-A90 Mineral<br />
fibre<br />
175 V or H 120/90 EXT-A90 Mineral<br />
fibre<br />
200 V or H 120/90 EXT-A90 Mineral<br />
fibre<br />
75, 100, 125, V or H - EXT-B Mineral<br />
150, 175 & 200<br />
fibre<br />
75 V or H 60/60 EXT-A60 Mineral<br />
fibre<br />
100 V or H 60/60 EXT-A60 Mineral<br />
fibre<br />
125 V or H 90/90 EXT-A90 Mineral<br />
fibre<br />
150 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
175 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
200 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
75, 100, 125, V or H - EXT-B Mineral<br />
150, 175 & 200<br />
fibre<br />
75 V or H 60/60 EXT-A60 Mineral<br />
fibre<br />
100 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
100 V or H 120/90 EXT-A90 Mineral<br />
fibre<br />
125 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
150 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
175 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
200 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
75, 100, 125, V or H - EXT-B Mineral<br />
150, 175 & 200<br />
fibre<br />
75 V or H 60/30 EXT-A30 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545b/01<br />
545b/03<br />
545b/04<br />
545b/05<br />
545b/06<br />
20 20 Nov 2011
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Product Name<br />
Rockspan Ultima<br />
(wall panel)<br />
Rainspan - Argeton<br />
terracotta tile<br />
system<br />
Rainspan - Linear<br />
system<br />
Rainspan - Parklex<br />
timber veneer<br />
system<br />
Rainspan -<br />
Rockpanel system<br />
Rainspan - Corium<br />
brick slip system<br />
Rainspan - Generic<br />
timber system<br />
Rainspan - Clicktile<br />
system<br />
Thickness<br />
(mm)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Fire Resistance<br />
Integrity/Insulation<br />
(minutes)<br />
LPS1181-1<br />
Grade<br />
Core<br />
Material<br />
100 V or H 90/60 EXT-A60 Mineral<br />
fibre<br />
125 V or H 90/60 EXT-A60 Mineral<br />
fibre<br />
150 V or H 120/90 EXt-A90 Mineral<br />
fibre<br />
175 V or H 120/90 EXT-A90 Mineral<br />
fibre<br />
200 V or H 120/90 EXT-A90 Mineral<br />
fibre<br />
75, 100, 125,<br />
150, 175 &<br />
V or H - EXT-B Mineral<br />
fibre<br />
150 V or H 240/240 EXT-A240 Mineral<br />
fibre<br />
175 V or H 240/240 EXT-A240 Mineral<br />
fibre<br />
200 V or H 240/240 EXT-A240 Mineral<br />
fibre<br />
120 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
150 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
175 V or H 180/180 EXT-A180 Mineral<br />
fibre<br />
120 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
150 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
175 V or H 180/180 EXT-A180 Mineral<br />
fibre<br />
120 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
150 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
175 V or H 180/180 EXT-A180 Mineral<br />
fibre<br />
120 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
150 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
175 V or H 180/180 EXT-A180 Mineral<br />
fibre<br />
120 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
150 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
175 V or H 180/180 EXT-A180 Mineral<br />
fibre<br />
120 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
150 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
175 V or H 180/180 EXT-A180 Mineral<br />
fibre<br />
120 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
150 V or H 120/120 EXT-A120 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545b/07<br />
545b/08<br />
545b/09<br />
545b/10<br />
545b/11<br />
545b/12<br />
545b/13<br />
545b/14<br />
Notes:<br />
1. LPCB Ref No. 545b/07 - 150mm and 175mm Rockspan Ultima wall panel joints are to be stitched on both internal and external faces<br />
using 4.7mm diameter x 20mm long self-tapping screws at 300mm centres, the 200mm panel does not require stitching.<br />
2. LPCB Ref No. 545b/13 to 545b/19, the thickness specified relates to the insulated panel thickness only and does not include the<br />
facade system depth.<br />
* Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the insulated panel.<br />
20 Nov 2011 21
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Euroclad Limited<br />
Wentloog Corporate Park, Wentloog Road, Cardiff CF3 2ER, United Kingdom<br />
Tel: +44 (0)2920 790722 • Fax: +44 (0)2920 793149<br />
E-mail: sales@euroclad.com • Website: www.euroclad.com<br />
Certificate No: 879a to LPS1181: Part 1<br />
Product Name<br />
Elite 1 (Roof<br />
System)<br />
Elite 2 (Roof<br />
System)<br />
Elite 3 (Roof<br />
System)<br />
Elite 4 (Roof<br />
System)<br />
Elite 51 (wall<br />
system)<br />
Elite 52 (wall<br />
system)<br />
Elite 53 (wall<br />
system)<br />
Elite 54 (wall<br />
system)<br />
Elite 55 (wall<br />
system)<br />
Elite 56 (wall<br />
system)<br />
Elite 57 (wall<br />
system)<br />
Elite 58 (wall<br />
system)<br />
Elite 60 (wall<br />
system)<br />
System<br />
Specification<br />
Thickness<br />
(mm)<br />
Wall panel<br />
orientation<br />
(H/V)<br />
Fire Resisitance<br />
(minutes)<br />
Integrity/Insulation<br />
Grade<br />
Core<br />
material<br />
203 - 252 - -/- EXT-B Glass Wool or Mineral<br />
Wool<br />
879a/05<br />
218 - 312 - -/- EXT-B Glass Wool or Mineral 879a/06<br />
Wool<br />
240 - 335 - -/- EXT-B Glass Wool or Mineral 879a/07<br />
Wool<br />
344 - 395 - -/- EXT-B Glass Wool or Mineral 879a/08<br />
Wool<br />
153 - 173 V -/- EXT-B Glass Wool or Mineral 879a/09<br />
Wool<br />
153 - 173 V 240 / 15 EXT-A15 Glass Wool or Mineral<br />
Wool<br />
153 - 173 V 240 / 30 EXT-A30 (note Mineral Wool<br />
4)<br />
153 - 173 V -/- EXT-B Glass Wool or Mineral 879a/10<br />
Wool<br />
153 - 173 V 240 / 15 EXT-A15 Glass Wool or Mineral<br />
Wool<br />
153 - 173 V 240 / 15 EXT-A30 (note Mineral Wool<br />
4)<br />
160 V -/- EXT-B Glass Wool or Mineral 879a/11<br />
Wool<br />
160 V 240 / 15 EXT-A15 Glass Wool or Mineral<br />
Wool<br />
160 V 240 / 30 EXT-A30 (note Mineral Wool<br />
4)<br />
150 - 170 V -/- EXT-B Glass Wool or Mineral 879a/12<br />
Wool<br />
150 - 170 V 240 / 15 EXT-A15 Glass Wool or Mineral<br />
Wool<br />
150 - 170 V 240 / 30 EXT-A30 (note Mineral Wool<br />
4)<br />
180 H -/- EXT-B Glass Wool or Mineral 879a/13<br />
Wool<br />
180 H 240 / 15 EXT-A15 Glass Wool or Mineral<br />
Wool<br />
180 H 240 / 30 EXT-A30 (note Mineral Wool<br />
4)<br />
181 H -/- EXT-B Glass Wool or Mineral 879a/14<br />
181 H 240 / 15 EXT-A15 Glass Wool or Mineral<br />
Wool<br />
181 H 240 / 30 EXT-A30 (note<br />
4)<br />
Mineral Wool<br />
168 H -/- EXT-B Glass Wool or Mineral<br />
Wool<br />
168 H 240 / 30 EXT-A30 (note Mineral Wool<br />
4)<br />
168 H 240 / 15 EXT-A15 Glass Wool or Mineral<br />
Wool<br />
177 H -/- EXT-B Glass Wool or Mineral<br />
Wool<br />
177 H 240 / 15 EXT-A15 Glass Wool or Mineral<br />
Wool<br />
177 H 240 / 30 EXT-A30 (note Mineral Wool<br />
4)<br />
200 H -/- EXT-B Glass Wool or Mineral<br />
Wool<br />
Cert.<br />
No.<br />
879a/15<br />
879a/16<br />
879a/17<br />
22 20 Nov 2011
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Product Name<br />
System<br />
Specification<br />
Thickness<br />
(mm)<br />
Wall panel<br />
orientation<br />
(H/V)<br />
Fire Resisitance<br />
(minutes)<br />
Integrity/Insulation<br />
Grade<br />
Core<br />
material<br />
200 H 240 / 15 EXT-A15 Glass Wool or Mineral<br />
Wool<br />
200 H 240 / 30 EXT-A30 (note<br />
4)<br />
Mineral Wool<br />
Cert.<br />
No.<br />
Notes:<br />
1. Where Elite wall systems are required to achieve grade EXT-A15, the internal liner sheet side lap joints must be stitched using steel<br />
rivets at 450mm centres. For grade EXT-A30 the internal liner sheet side lap joints must be stitched at 300mm centres.<br />
2. Stitching can be removed from the EXT-A15 wall systems providing that the maximum spacing between sheeting rails is reduced to<br />
1.5m and the internal liner is either Euroclad 1000/32 or MW5 profiles.<br />
3. For wall systems the sheeting rail spacing shall be a maximum of 2m for EXT-B, EXT-A15 & EXT-A30, the external liner must be<br />
fixed to the channels of the spacer system using self-drilling, self-tapping screws at nominal 400mm centres for all grades.<br />
4. For grade EXT-A30 systems The minimum permissible stone mineral wool thickness is 180mm, or for systems with horizontally laid<br />
external weather sheets where the eurobar spacer rails are vertical and the insulation in the core is supported by additional steel Z-<br />
<strong>section</strong> supports, and with a minimum density of the insulation of 33kg/m³ the minimum insulation thickness can be reduced to<br />
150mm.<br />
5. For Elite roof systems 1 - 4 the maximum purlin spacing is 1.8m.<br />
6. Please refer to BRE Assessment Report CC248407 for approved alternative spacer systems, internal & external profiles, internal &<br />
external profile coatings and insulation cores for the Elite systems 1, 2, 3, 4, 51, 52, 53, 54, 55, 56, 57, 58 & 60.<br />
Hemsec Manufacturing Limited<br />
Stoney Lane, Rainhill, Prescot, Merseyside L35 9LL, United Kingdom<br />
Tel: +44 (0)151 426 7171 • Fax: +44 (0)151 493 1331<br />
E-mail: sales@hemsec.com • Website: www.hemsec.com<br />
Certificate No: 558b to LPS 1181: Part 1: Issue 1<br />
Product Name<br />
Specification<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Cert. No.<br />
Longclad LC1150 Wall (wall panels) 50mm to 175mm - - EXT-B PIR 558b/01<br />
Longdeck LD1150 Wall (roof 50mm to 175mm - - EXT-B PIR 558b/02<br />
panels)<br />
Longclad LC1150 Wall (wall panels) 100mm to<br />
60 30 EXT-A30 PIR 558b/03<br />
175mm<br />
Longdeck LD1150 Wall (roof 125mm to<br />
52 40 EXT-A30 PIR 558b/04<br />
panels)<br />
175mm<br />
SIP Firecheck wall system 160 to 287 75 75 EXT- PUR 558b/05<br />
A60<br />
257.5 to 329.5 101 101 EXT-A90 PUR 558b/06<br />
Notes:<br />
1. Longclad LC1150 Wall panels LPCB Ref. No. 558b/01 & 558b/03 can be installed with the long joints in the vertical or horizontal<br />
orientation.<br />
2. The joints of the Longclad LC1150 wall panel’s 558b/01 should be stitched at 150mm centres on the internal face.<br />
3. The joints of the Longdeck LD1150 roof panel’s 558b/02 should be stitched at 150mm centres on the internal face.<br />
4. The joints of the Longclad LC1150 wall panel’s 558b/03 should be stitched at 150mm centres on the internal and external face.<br />
When installed the supporting framework shall provide support at a maximum of 4m centres both horizontally & vertically.<br />
5. The joints of the Longdeck LD1150 roof panel’s 558b/04 should be stitched at 150mm centres on the internal and external face.<br />
6. LPCB Ref 558b/05 - SIP Firecheck wall system was tested and is approved to LPS 1181-1 as a non load-bearing, non structural builtup<br />
wall system of the following configuration; Rigid polyurethane foam core (95mm to 222mm thick) sandwiched between 15 mm<br />
orientated strand boards (Krono OSB-3), the panel size was 1.2m x 3.0m and installed with 3 metre joints vertical. The system was<br />
clad on the fire exposed face with two layers of British Gypsum wall boards; A single layer of ‘Gyproc’ 12.5mm wall board (outer layer)<br />
and a single layer of ‘Gyproc Fireline’ 12.5mm board (inner layer), wall board layer joints were staggered by 600mm and fixed to<br />
softwood timber battens positioned at 600mm centres with 3.5mm x 50mm dry wall screws at 300mm centres. The system was tested<br />
with Hemsec 175mm thick Longdeck LD1150 PIR core roof panels.<br />
7. LPCB Ref 558b/06 - SIP Firecheck wall system is approved to LPS 1181-1 as a non load-bearing, non structural built up wall system<br />
of the following configuration; Rigid polyurethane foam core (150mm to 222mm thick) sandwiched between 15 mm orientated strand<br />
boards (Krono OSB-3), the panel size is 1.2m x 3.0m and installed with 3 metre joints vertical and consisting of 148mm deep x 70mm<br />
thick x 3000mm long timber spline joints inserted into 35mm pre-formed rebates in the core insulation, the joints are fixed with<br />
adhesive and nail fixings at 100mm centres. The system is clad on the fire exposed face with two layers of British Gypsum wall<br />
boards; A single layer of ‘Gyproc’ 12.5mm wall board (outer layer) and a single layer of ‘Gyproc Fireline’ 15mm board (inner layer),<br />
20 Nov 2011 23
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
with the wall board joints between layers staggered by 600mm and fixed to softwood timber battens 50mm x 50mm spaced at 600mm<br />
centres with 3.5mm x 50mm dry wall screws at 300mm centres, the stud cavity is filled with Knauf Rocksilk Universal slab RW33<br />
insulation.<br />
ISOCAB France S.A.<br />
Avenue de la Gironde, Z.I. Petite Synthe, 59640 Dunkerque, France<br />
Tel: +33 328 29 26 30 • Fax: +33 328 60 11 93<br />
E-mail: info@isocabfrance.fr • Website: www.isocab.be<br />
Certificate No: 465a to LPS 1181: Part 1<br />
Product Name<br />
Specification<br />
System Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Cert. No.<br />
ISOCAB Industrial (wall and roof panel) 40 - 200 - - EXT-B PIR 465a/01<br />
Notes:<br />
1. Wall panels are laid vertically.<br />
2. Both wall and roof panels require internal stitching at 300mm centres using 3.2mm diameter x 25mm screws and internal steel<br />
flashings 0.6mm thick x 120mm wide overlaying three beads of Lorient intumescent mastic, stitched at 150mm centres using 3.2mm<br />
diameter x 16mm screws.<br />
Kingspan Insulation Limited<br />
Pembridge, Leominster, Herefordshire HR6 9LA, United Kingdom<br />
Tel: +44 (0)1544 388601 • Fax: +44 (0)1544 388888<br />
E-mail: info.uk@insulation.kingspan.com • Website: www.insulation.kingspan.com<br />
Certificate No: 388b to LPS 1181: Part 1<br />
Product Name<br />
Roofing systems incorporating Thermaroof TR26<br />
LPC/FM zero ODP Insulation (also available as<br />
Thermataper TT46 for cut-to-fall roofing systems)<br />
Roofing systems incorporating Thermaroof TR27<br />
LPC/FM zero ODP Insulation (also available as<br />
Thermataper TT47 for cut-to-fall roofing systems)<br />
Specification<br />
Thickness<br />
(system)<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
65 to 155 - - EXT-<br />
B<br />
65 to 155 - - EXT-<br />
B<br />
Core<br />
Material<br />
HCFCfree<br />
PIR<br />
HCFRfree<br />
PIR<br />
Cert.<br />
No.<br />
388b/01<br />
388b/02<br />
Notes:<br />
1. LPCB Ref 388b/01 Thermaroof TR26/ LPC/FM Mechanically Fixed Insulated metal deck system is approved to LPS 1181-1 as a built<br />
up roof system of the following configuration:<br />
Corus D35 Roof Decking (0.7mm thick) or equivalent; deck panel lap joints stitched at 400mm centres.<br />
With or without Corus Kalzip/Icopal Monofilament 250μm or equivalent approved Vapour Control Layer (VCL); loose laid on top of<br />
the deck.<br />
Kingspan TR26/TT46 LPC/FM foil faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 2.4m x 1.2m sheets<br />
(approved at 30mm to 120mm thick) the boards through fixed to deck using 140mm long SFS drill point roof fasteners at 3.8<br />
fixings per m² with a 70mm diameter metal plate washer.<br />
Weather sealed using Protan SE membrane (1.2mm x 1000mm) having a 120mm lap joint with a 40mm hot air weld, or<br />
equivalent woven polyester reinforced PVC water proof membrane, mechanically fixed to the roof system using RP75 x 100mm<br />
telescopic tube washers and 4.8 x 60mm screw fixed to the metal deck at 150mm centres. The membrane must be restrained<br />
around the edges of the deck with an edge restraint bar stitched at 400mm centres.<br />
The roof system was tested in combination with LPCB approved PIR core wall panels.<br />
2. LPCB Ref 388b/02 Thermaroof TR27 LPC/FM Mechanically Fixed Insulated metal deck system is approved to LPS 1181-1 as a built<br />
up roof system of the following configuration:<br />
Corus D35 Roof Decking (0.7mm thick) or equivalent; deck panel lap joints stitched at 400mm centres.<br />
With or without Corus Kalzip/Icopal Monofilament 250μm or equivalent approved Vapour Control Layer (VCL); loose laid on top of<br />
the deck.<br />
24 20 Nov 2011
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Kingspan TR27/TT47 LPC/FM glass tissue faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 2.4m x 1.2m<br />
sheets (approved at 30mm to 120mm thick) the boards through fixed to deck using 140mm long SFS drill point roof fasteners at<br />
3.8 fixings per m² with a 70mm diameter metal plate washer.<br />
Weather sealed using Protan SE membrane (1.2mm x 1000mm) having a 120mm lap joint with a 40mm hot air weld, or<br />
equivalent woven polyester reinforced PVC water proof membrane, mechanically fixed to the roof system using RP75 x 100mm<br />
telescopic tube washers and 4.8 x 60mm screw fixed to the metal deck at 150mm centres. The membrane must be restrained<br />
around the edges of the deck with an edge restraint bar stitched at 400mm centres.<br />
The roof system was tested in combination with LPCB approved PIR core wall panels.<br />
3. LPCB Ref. 388b/01 and 388b/02 certification is also valid for insulation boards manufactured at Kingspan Insulation Ltd,<br />
Castleblayney, County Monaghan, Ireland (LPCB FPC reference number 858).<br />
Kingspan Ltd<br />
Carrickmacross Road, Kingscourt, Co. Cavan, Ireland<br />
Tel: +353 42 969 8572 • Fax: +353 42 969 8576/77<br />
E-mail: info.irl@kingspanpanels.com • Website: www.kingspanpanels.com<br />
Certificate No: 186a to LPS 1181: Part 1: Issue 1.1<br />
Product Name<br />
Kingspan Benchmark<br />
Trespa System<br />
Kingspan KS1000 RW<br />
(roof and wall panel)<br />
Kingspan KS1000 RW<br />
(wall panel)<br />
Kingspan KS1000<br />
RW/FW30 (wall panel)<br />
Kingspan KS2000 RW<br />
(roof panel)<br />
Kingspan KS1000 SF<br />
(roof and wall panel)<br />
Kingspan KS1000 SF<br />
(wall panel)<br />
Kingspan KS1000<br />
SF/FW30 (wall panel)<br />
Kingspan KS1000 BU<br />
(roof and wall panel)<br />
Kingspan KS1000 LJ<br />
(wall panel)<br />
Kingspan KS1000 LJ<br />
(roof panel)<br />
Kingspan KS1000 TS<br />
(roof panel)<br />
Kingspan KS2000 TS<br />
(roof panel)<br />
Kingspan KS1000 RT<br />
Rooftile (roof panel)<br />
Kingspan KS500 Zip &<br />
KS1000 Zip (roof panel)<br />
Kingspan KS1000 LP<br />
(roof panel)<br />
Kingspan KS1000 CR<br />
(roof panel)<br />
Kingspan KS1000 DR<br />
(wall panel)<br />
Kingspan KS1000 DR<br />
(roof panel)<br />
Kingspan KS1000 TD<br />
(roof panel)<br />
BenchmarkTopspan (roof<br />
panel) (roof panel)<br />
Specification<br />
Thickness<br />
(mm)<br />
Specification<br />
Wall panel<br />
orientation<br />
(H/V)<br />
(note 1)<br />
Specification<br />
Kingspan<br />
Model<br />
Specification<br />
Ref. (note 2)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(minutes)<br />
LPS<br />
1181-<br />
1<br />
Grade<br />
Core<br />
Material<br />
(note 3)<br />
95 - 150 V or H 31 Rev 1 - EXT-B Ecosafe<br />
PIR<br />
260a/70<br />
30 - 120 V or H 17 Rev 6 - EXT-B Ecosafe 186a/42<br />
PIR<br />
40 - 120 V 17 Rev 6 144 / 18 EXT- Ecosafe 186a/38<br />
A15 PIR<br />
100 & 120 V 17 Rev 6 241 / 43 EXT- Ecosafe 186a/40<br />
A30 PIR<br />
30 - 120 - 27 Rev 2 - EXT-B Ecosafe 260a/69<br />
PIR<br />
30 - 120 V or H 19 Rev 4 - EXT-B Ecosafe 186a/43<br />
PIR<br />
40 - 120 V 19 Rev 4 144 / 18 EXT- Ecosafe 186a/39<br />
A15 PIR<br />
100 - 120 V 19 Rev 4 241 / 43 EXT- Ecosafe 186a/41<br />
A30 PIR<br />
30 - 120 V 5 Rev 5 - EXT-B Ecosafe 186a/46<br />
PIR<br />
60 - 120 V 4 Rev 4 - EXT-B Ecosafe 186a/44<br />
PIR<br />
80 - 120 - 4 Rev 4 - EXT-B Ecosafe 186a/45<br />
PIR<br />
30 - 120 - 12 Rev 3 - EXT-B Ecoafe 186a/47<br />
PIR<br />
30 - 120 - 28 Rev 1 - EXT-B Ecosafe 260a/68<br />
PIR<br />
45 - 100 - 10 Rev 3 - EXT-B PIR 279a/10<br />
Cert.<br />
No.<br />
45 - 124 - 8 Rev 8 - EXT-B Ecosafe<br />
PIR<br />
260a/54<br />
45 - 115 - 2 Rev 4 - EXT-B Ecosafe 279a/65<br />
PIR<br />
45 - 115 - 3 Rev 4 - EXT-B Ecosafe 279a/66<br />
PIR<br />
40 - 100 V 29 Rev 0 - EXT-B PIR 279a/16<br />
80 - 100 V 29 Rev 0 69 / 23 EXT-<br />
A15<br />
PIR 279a/17<br />
40 - 100 - 29 Rev 0 - EXT-B Ecosafe 279a/34<br />
PIR<br />
34, 46, 68, 80, - 30 Rev 1 - EXT-B Ecosafe 279a/29<br />
100 & 120<br />
PIR<br />
66 - 15 Rev 4 - EXT-B PIR 279a/31<br />
20 Nov 2011 25
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Product Name<br />
Kingspan KS600 - 1200<br />
MR, FL, FL-S, EB, WV,<br />
MM, CX , PL, Benchmark<br />
Evolution & KS1000 TL,<br />
Benchmark Louvre DW &<br />
Benchmark Curve DW<br />
(wall panel)<br />
Kingspan KS600 - 1000<br />
MR, FL, FL-S, EB, WV,<br />
MM, CX, PL, Benchmark<br />
Evolution & KS1000 TL<br />
(wall panel)<br />
Kingspan KS600 - 1000<br />
LS (wall panel)<br />
Kingspan KS600 - 1000,<br />
Benchmark Render DW<br />
(wall panel)<br />
Kingspan KS600 - 1000<br />
FX (wall panel)<br />
Kingspan KS1000 EP<br />
Energi (wall and roof<br />
panel)<br />
Kingspan KS1000 FC<br />
(wall and roof panel )<br />
Kingspan KS1000 FC<br />
(wall and roof panel)<br />
Kingspan KS1000 FC<br />
(wall panel)<br />
Kingspan KS1000 FC<br />
(wall panel)<br />
Kingspan Benchmark<br />
Metallic ACM Tray<br />
Kingspan Benchmark<br />
Wood Composite System<br />
Kingspan Benchmark<br />
Ceramic Granite System<br />
Thermabrick Façade<br />
system<br />
Kingspan Benchmark<br />
Ceramic Tile System<br />
Kingspan KS1100 CS<br />
(wall panel)<br />
Kingspan KS1100 CS<br />
(ceiling panel)<br />
Specification<br />
Thickness<br />
(mm)<br />
Specification<br />
Wall panel<br />
orientation<br />
(H/V)<br />
(note 1)<br />
Specification<br />
Kingspan<br />
Model<br />
Specification<br />
Ref. (note 2)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(minutes)<br />
LPS<br />
1181-<br />
1<br />
Grade<br />
Core<br />
Material<br />
(note 3)<br />
45 - 140 V or H 18 Rev 8 - EXT-B Ecosafe<br />
PIR<br />
70 - 140 V 18 Rev 8 40 / 15 EXT-<br />
A15<br />
Ecosafe<br />
PIR<br />
100 - 140 V 18 rev 8 132 / 28 EXT-<br />
A30<br />
Ecosafe<br />
PIR<br />
80 - 140 H 9 Rev 5 - EXT-B Ecosafe<br />
PIR<br />
45 - 100 V or H 20 Rev 2 - EXT-B Ecosafe<br />
PIR<br />
70 - 100 V 20 Rev 2 40 / 15 EXT-<br />
A15<br />
Ecosafe<br />
PIR<br />
45 - 100 V or H 21 Rev 4 - EXT-B Ecosafe<br />
PIR<br />
68 - 100 V 25 Rev 0 - EXT-B Ecosafe<br />
PIR<br />
Cert.<br />
No.<br />
260a/37<br />
260a/36<br />
260a/64<br />
260a/67<br />
260a/49<br />
260a/50<br />
260a/53<br />
279a/30<br />
34 - 100 V or H 16 Rev 3 - EXT-B Ecosafe<br />
PIR<br />
279a/32<br />
34 - 100 V or H 16 Rev 3 - EXT - PIR 279a/19<br />
B<br />
68 - 100 V 16 Rev 3 34 / 15 EXT- PIR 279a/21<br />
A15<br />
100 V 16 Rev 3 79 / 34 EXT- PIR 279a/28<br />
A30<br />
95 - 150 V or H 26 Rev 5 - EXT-B Ecosafe 260a/62<br />
PIR<br />
94 - 149 V or H 24 Rev 3 - EXT-B Ecosafe 260a/59<br />
PIR<br />
95 - 150 V or H 23 Rev 4 - EXT-B Ecosafe 260a/58<br />
PIR<br />
120 - 150 V 23 Rev 4 73 / 35 EXT- Ecosafe 260a/63<br />
A30 PIR<br />
110 - 165 V 22 Rev 4 - EXT-B Ecosafe 260a/60<br />
PIR<br />
135 - 165 V 22 Rev 4 220 / 83 EXT- Ecosafe 260a/61<br />
A60 PIR<br />
80 - 135 V or H 14 Rev 5 - EXT-B Ecosafe 260a/35<br />
PIR<br />
105 - 135 V 14 Rev 5 32 / 32 EXT- Ecosafe 260a/34<br />
A30 PIR<br />
80 - 200 V 13 Rev 2 - EXT - Ecosafe 279c/15<br />
B PIR<br />
80 - 200 - 13 Rev 2 - EXT-B Ecosafe 279c/16<br />
PIR<br />
Notes:<br />
1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
2. The Kingspan Model Specification documents contain full system details including panel fixing requirements, joint seals and stitching<br />
details as applicable, reference must be made to the appropriate Model Specification to define the specific approved installation<br />
requirements. Copies of Model Specification’s are available on request, Please contact the Kingspan Envirocare De<strong>part</strong>ment.<br />
3. Core material solutions listed as Ecosafe PIR are CFC/HCFC/HFC Free, Low GWP. Core material solutions listed as PIR are<br />
CFC/HCFC Free.<br />
26 20 Nov 2011
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Kingspan Ltd.<br />
Greenfield Business Park No. 2, Greenfield, Holywell, Flintshire CH8 7HU, United Kingdom<br />
Tel: +44 (0)1352 716100 • Fax: +44 (0)1352 716161<br />
E-mail: info@kingspanpanels.com • Website: www.kingspanpanels.com<br />
Certificate No: 260a to LPS 1181: Part 1: Issue 1.1<br />
Product Name<br />
Kingspan Benchmark<br />
Trespa System<br />
Kingspan KS1000 RW<br />
(roof and wall panel)<br />
Kingspan KS1000 RW<br />
(wall panel)<br />
Kingspan KS1000<br />
RW/FW30 (wall panel)<br />
Kingspan KS2000 RW<br />
(roof panel)<br />
Kingspan KS1000 SF<br />
(roof and wall panel)<br />
Kingspan KS1000 SF<br />
(wall panel)<br />
Kingspan KS1000<br />
SF/FW30 (wall panel)<br />
Kingspan KS1000 BU<br />
(roof and wall panel)<br />
Kingspan KS1000 LJ<br />
(wall panel)<br />
Kingspan KS1000 LJ<br />
(roof panel)<br />
Kingspan KS1000 TS<br />
(roof panel)<br />
Kingspan KS2000 TS<br />
(roof panel)<br />
Kingspan KS1000 RT<br />
Rooftile (roof panel)<br />
Kingspan KS500 Zip &<br />
KS1000 Zip (roof panel)<br />
Kingspan KS1000 LP<br />
(roof panel)<br />
Kingspan KS1000 CR<br />
(roof panel)<br />
Kingspan KS1000 DR<br />
(wall panel)<br />
Kingspan KS1000 DR<br />
(roof panel)<br />
Kingspan KS1000 TD<br />
(roof panel)<br />
Kingspan Benchmark<br />
Topspan (roof panel)<br />
Kingspan KS600 -1200<br />
MR, FL, FL-S, EB, WV,<br />
MM, CX , PL,<br />
Benchmark Evolution,<br />
KS1000 TL, Benchmark<br />
Louvre DW &<br />
Benchmark Curve DW<br />
(wall panel)<br />
Kingspan KS600 - 1000<br />
MR, FL, FL-S, EB, WV,<br />
MM, CX, PL,<br />
Benchmark Evolution &<br />
KS1000 TL (wall panel)<br />
Specification<br />
Thickness<br />
(mm)<br />
Specification<br />
Wall Panel<br />
Orientation<br />
(H/V)<br />
(note 1)<br />
Specification<br />
Kingspan<br />
Model<br />
Specification<br />
Ref. (note 2)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(minutes)<br />
LPS<br />
1181 -<br />
1<br />
Grade<br />
Core<br />
Material<br />
(note 3)<br />
95 - 150 V or H 31 Rev 1 - EXT-B Ecosafe<br />
PIR<br />
260a/70<br />
30 - 120 V or H 17 Rev 6 - EXT-B Ecosafe 260a/42<br />
PIR<br />
40 - 120 V 17 Rev 6 144 / 18 EXT- Ecosafe 260a/38<br />
A15 PIR<br />
100 & 120 V 17 Rev 6 241 / 43 EXT- Ecosafe 260a/40<br />
A30 PIR<br />
30 - 120 - 27 Rev 2 - EXT-B Ecosafe 260a/69<br />
PIR<br />
30 - 120 V or H 19 Rev 4 - EXT-B Ecosafe 260a/43<br />
PIR<br />
40 - 120 V 19 Rev 4 144 / 18 EXT- Ecosafe 260a/39<br />
A15 PIR<br />
120 V 19 Rev 4 241 / 43 EXT- Ecosafe 260a/41<br />
A30 PIR<br />
30 - 120 V 5 Rev 5 - EXT-B Ecosafe 260a/46<br />
PIR<br />
60 - 120 V 4 Rev 4 - EXT-B Ecosafe 260a/44<br />
PIR<br />
80 - 120 - 4 Rev 4 - EXT-B Ecosafe 260a/45<br />
PIR<br />
30 - 120 - 12 Rev 3 - EXT-B Ecosafe 260a/47<br />
PIR<br />
30 - 120 - 28 Rev 1 - EXT-B Ecosafe 260a/68<br />
PIR<br />
45 -100 - 10 Rev 3 - EXT-B PIR 279a/10<br />
45 -124 - 8 Rev 8 - EXT-B Ecosafe<br />
PIR<br />
260a/54<br />
45 - 115 - 2 Rev 4 - EXT-B Ecosafe 279a/65<br />
PIR<br />
45 - 115 - 3 Rev 4 - EXT-B Ecosafe 279a/66<br />
PIR<br />
40 - 100 V 29 Rev 0 - EXT-B PIR 279a/19<br />
80 - 100 V 29 Rev 0 69 / 23 EXT-<br />
A15<br />
PIR 279a/17<br />
40 - 100 - 29 Rev 0 - EXT-B Ecosafe 279a/34<br />
PIR<br />
34, 46, 68, 80, - 30 Rev 1 - EXT-B Ecosafe 279a/29<br />
100 & 120<br />
PIR<br />
66 - 15 Rev 4 - EXT-B PIR 279a/31<br />
45 - 140 V or H 18 Rev 8 - EXT-B Ecosafe<br />
PIR<br />
70 - 140 V 18 Rev 8 40 / 15 EXT-<br />
A15<br />
Ecosafe<br />
PIR<br />
Cert.<br />
No.<br />
260a/37<br />
260a/36<br />
20 Nov 2011 27
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Product Name<br />
Kingspan KS600 - 1000<br />
LS (wall panel)<br />
Kingspan KS600 - 1000,<br />
Benchmark Render DW<br />
(wall panel)<br />
Kingspan KS600 - 1000<br />
FX (wall panel)<br />
Kingspan KS1000 EP<br />
Energi (wall and roof<br />
panel)<br />
Kingspan KS1000 FC<br />
(wall and roof panel )<br />
Kingspan KS1000 FC<br />
(wall and roof panel)<br />
Kingspan KS1000 FC<br />
(wall panel)<br />
Kingspan KS1000 FC<br />
(wall panel)<br />
Kingspan Benchmark<br />
Metallic ACM Tray<br />
Kingspan Benchmark<br />
Wood Composite<br />
System<br />
Kingspan Benchmark<br />
Ceramic Granite System<br />
Thermabrick Façade<br />
system<br />
Kingspan Benchmark<br />
Ceramic Tile System<br />
Kingspan KS1100 CS<br />
(wall panel)<br />
Kingspan KS1100 CS<br />
(ceiling panel)<br />
Specification<br />
Thickness<br />
(mm)<br />
Specification<br />
Wall Panel<br />
Orientation<br />
(H/V)<br />
(note 1)<br />
Specification<br />
Kingspan<br />
Model<br />
Specification<br />
Ref. (note 2)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(minutes)<br />
LPS<br />
1181 -<br />
1<br />
Grade<br />
Core<br />
Material<br />
(note 3)<br />
100 - 140 V 18 Rev 8 132 / 28 EXT-<br />
A30<br />
Ecosafe<br />
PIR<br />
80 - 140 H 9 Rev 5 - EXT-B Ecosafe<br />
PIR<br />
45 - 100 V or H 20 Rev 2 - EXT-B Ecosafe<br />
PIR<br />
Cert.<br />
No.<br />
260a/64<br />
260a/67<br />
260a/49<br />
70 - 100 V 20 Rev 2 40 / 15 EXT- Ecosafe 260a/50<br />
A15 PIR<br />
45 - 100 V or H 21 Rev 4 - EXT-B Ecosafe 260a/53<br />
68 - 100 V 25 Rev 0 - EXT-B Ecosafe<br />
PIR<br />
279a/30<br />
34 - 100 V or H 16 Rev 3 - EXT-B Ecosafe 279a/32<br />
PIR<br />
34 - 100 V or H 16 Rev 3 - EXT-B PIR 279a/19<br />
68 - 100 V 16 Rev 3 34 / 15 EXT-<br />
A15<br />
PIR 279a/21<br />
100 V 16 Rev 3 79 / 34 EXT- PIR 279a/28<br />
A30<br />
95 - 150 V or H 26 Rev 5 - EXT-B Ecosafe 260a/62<br />
PIR<br />
94 - 149 V or H 24 Rev 3 - EXT-B Ecosafe 260a/59<br />
PIR<br />
95 - 150 V or H 23 Rev 4 - EXT-B Ecosafe<br />
PIR<br />
120 - 150 V 23 Rev 4 73 / 35 EXT- Ecosafe<br />
A30 PIR<br />
110 - 165 V 22 Rev 4 - EXT-B Ecosafe<br />
PIR<br />
135 - 165 V 22 Rev 4 220 / 83 EXT- Ecosafe<br />
A60 PIR<br />
80 - 135 V or H 14 Rev 5 - EXT-B Ecosafe<br />
PIR<br />
105 - 135 V 14 Rev 5 32 / 32 EXT- Ecosafe<br />
A30 PIR<br />
80 - 200 V 13 Rev 2 - EXT-B Ecosafe<br />
PIR<br />
80 - 200 - 13 Rev 2 - EXT-B Ecosafe<br />
PIR<br />
260a/58<br />
260a/63<br />
260a/60<br />
260a/61<br />
260a/35<br />
260a/34<br />
279c/15<br />
279c/16<br />
Notes:<br />
1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
2. The Kingspan Model Specification documents contain full system details including panel fixing requirements, joint seals and stitching<br />
details as applicable, reference must be made to the appropriate Model Specification to define the specific approved installation<br />
requirements. Copies of Model Specifications are available on request. Please contact the Kingspan Envirocare De<strong>part</strong>ment.<br />
3. Core material solutions listed as Ecosafe PIR are CFC/HCFC/HFC Free, Low GWP. Core material solutions listed as PIR are<br />
CFC/HCFC Free.<br />
Modular Panel Systems Limited<br />
Mohill, Co.Leitrim, Ireland<br />
Tel: +353 719631162 • Fax: +353 719651979<br />
E-mail: info@modular.ie • Website: www.modular.ie<br />
Certificate No: 750b to LPS 1181: Part 1<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Cert. No.<br />
PIR ExoClad (wall and ceiling panel) 50 - - EXT-B PIR 750b/01<br />
28 20 Nov 2011
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Cert. No.<br />
PIR ExoClad (wall panel) 50 120 16 EXT-A15 PIR 750b/02<br />
Notes:<br />
1. The joints of the Exoclad panels 750b/01 should be stitched with 6.3mm x 22mm long self tapping screws @ 250mm centres on the<br />
external overlap and stitched with 4.8mm dia x 10mm stainless steel rivets @ 250mm centres on the internal face.<br />
2. Wall panels to be orientated vertically only.<br />
3. Exoclad wall panels 750b/02, panel joints external overlap stitched with stainless steel rivets and screwed at 100 mm centres. The<br />
internal joint is stitched at 100mm centres and protected with a 250mm wide by 50mm deep insulated cover strip stitched at 100mm<br />
centres.<br />
N.V. Joris IDE<br />
Hille 174, B-8750, Zwevezele, Belgium<br />
Tel: +44 (0)1928 571 444 • Fax: +44 (0)1928 571 488<br />
E-mail: division.export@joriside.co.uk • Website: www.joriside.co.uk<br />
Hille 174, B-8750, Zwevezele, Belgium<br />
Tel: +44 (0)1928 571 444 • Fax: +44 (0)1928 571 488<br />
E-mail: sales@joriside.co.uk • Website: www.joriside.co.uk<br />
Certificate No: 700a to LPS1181: Part 1: Issue 1<br />
Product Name<br />
Specification<br />
System<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Isotherm Built up system (wall panels) 200 - - EXT-B Glass 700a/06<br />
mineral wool<br />
Isotherm Built up system (roof panels) 220 - - EXT-B Glass 700a/07<br />
mineral wool<br />
JI ROOF 1+2 1000 (roof and wall panels) 30 - 120 - - EXT-B PIR 700a/09<br />
JI ROOF 1+2 1000 (wall panel) 60 - 120 67 17 EXT- PIR 700a/10<br />
A15<br />
JI ROOF 1+2 1000 with Tile System (roof 100 - 120 - - EXT-B PIR 700a/11<br />
panels)<br />
JI WALL SF 1060/1000/900/600 (wall 60 - 120 - - EXT-B PIR 700a/12<br />
panels)<br />
JI WALL SF 1060/1000/900/600 (wall 60 - 120 61 20 EXT- PIR 700a/13<br />
panels -vertical orientation only)<br />
A15<br />
JI WALL SF 1060/1000/900/600 (wall 60 - 120 30 15 EXT- PIR 700a/14<br />
panels)<br />
A15<br />
JI PERMAPAN 1100 (roof panels) 40-100 - - EXT-B PIR 700a/15<br />
Cert.<br />
No.<br />
Notes:<br />
1. LPCB Ref. No. 700a/06 internal linings to be horizontal and external linings to be vertical<br />
2. LPCB Ref. No. 700a/09 roof and wall panels fixed through every valley with 5.5mm self drilling/tapping screws into the roof and wall<br />
rail locations. Roof panel overlaps between adjoining panels shall be stitched at 300mm centres with 4.8mm self drilling/tapping<br />
screws or equivalent.<br />
3. LPCB Ref. No. 700a/09 wall panels can be laid with the long joints in the vertical or horizontal orientation.<br />
4. LPCB Ref. No. 700a/10 wall panels to be laid with the long joints in the horizontal orientation only. The panels were fixed through<br />
every valley with 5.5mm self drilling/tapping screws into the wall rail locations. The panel overlaps between panel joints were stitched<br />
at 250mm centres with 4.8mm self drilling/tapping screws. Maximum unsupported span between rails 1760mm.<br />
5. LPCB Ref. No. 700a/11 roof panels fixed through every valley with 5.5mm self drilling/tapping screws into the roof rail locations. The<br />
panel overlaps between panel joints were stitched at 300mm centres with 4.8mm self drilling/tapping screws. The tile system<br />
comprised of timber battens 50mm x 25mm fixed to the crown of every profile overlayed with single roman clay tiles with a maximum<br />
load of 42kg/m2.<br />
6. LPCB Ref. No. 700a/12 wall panels can be laid with the long joints in the vertical or horizontal orientation.<br />
7. LPCB Ref. No. 700a/13 wall panels to be laid with the long joints in the vertical orientation only, the panel joints shall be stitched on<br />
the fire side with 5.5mm x 50mm self tapping screws at maximum centres of 100mm.<br />
8. LPCB Ref. No. 700a/14 wall panels can be laid with the long joints in the vertical or horizontal orientation, the panel joints shall be<br />
stitched on the fire side with 5.5mm x 50mm self tapping screws at maximum centres of 100mm.<br />
9. LPCB Ref. No 700a/15. Roof panel overlaps between adjoining panels shall be stitched at 300mm centres with 4.8mm self<br />
drilling/tapping screws or equivalent.<br />
20 Nov 2011 29
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Quinn Therm Limited<br />
Scotchtown, Ballyconnell, Co. Cavan, Ireland<br />
Tel: +353 49 952 5604 • Fax: +353 49 952 5601<br />
E-mail: info@quinn-therm.com • Website: www.quinn-therm.com<br />
Certificate No: 893a to LPS1181: Part 1<br />
Product Name<br />
QRFR Fully adhered Insulating metal<br />
deck roof system<br />
QRFR Mechanically Fixed metal deck<br />
roof system<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
(min)<br />
Integrity<br />
Fire Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
85 - 185 - - EXT-<br />
B<br />
85 - 185 - - EXT-<br />
B<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
PIR 893a/01<br />
PIR 893a/02<br />
Notes:<br />
1. LPCB Ref 893a/01 QRFR Fully adhered Insulating metal deck roof system is approved to LPS 1181-1 as a built-up roof system of the<br />
following configuration:<br />
• Steadmans AS34 single skin roof profile deck (0.7mm thick); deck panel lap joints stitched at 250mm centres.<br />
• Multilfold 250µm Vapour Control Layer (VCL) laid on top of the deck, with the VCL cut back to within 75mm from the edge of the<br />
deck perimeter and further protected by flashing installed to form an ‘upstand’ around the perimeter of the roof system.<br />
• 150mm thick Quinntherm QRFR glass fibre tissue faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 2.4m x<br />
1.2m sheets (tested at 150mm thick, but available and approved between 50mm to 150mm thick), the boards being through fixed<br />
to the steelwork using 6.3 x 175mm fastec CR10 fluro carbon coated screws, with discs, at six fixings per m2<br />
• Weather sealed using a Sika-Trocal SGK 1.5 (1.5mm x 1100mm) water proof membrane adhered to the Quinntherm Insulation<br />
using Sika-Trocal C300 adhesive at a rate of 250 g/m².<br />
• The 150mm insulation roof system tested incorporated a 150 x 200mm external edge flashing and a 300 x 300mm internal<br />
roof/wall 1.6mm galvanised steel flashing.<br />
• The roof system was tested in combination with LPCB approved PIR core wall panels.<br />
2. LPCB Ref 893a/02 QRFR Mechanically fixed Insulating metal deck roof system is approved to LPS 1181-1 as a built-up roof system<br />
of the following configuration:<br />
• Steadmans AS34 single skin roof profile deck (0.7mm thick); deck panel lap joints stitched at 300mm centres.<br />
• Multilfold 250µm Vapour Control Layer (VCL) laid on top of the deck, with the VCL cut back to within 75mm from the edge of the<br />
deck perimeter and further protected by flashing installed to form an ‘upstand’ around the perimeter of the roof system.<br />
• 150mm thick Quinntherm QRFR foil faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 2.4m x 1.2m sheets<br />
(tested at 150mm thick, but available and approved between 50mm to 150mm thick), the boards being through fixed to the<br />
steelwork using 6.3 x 175mm fastec CR10 fluro carbon coated screws in a 500mm x 500mm square pattern.<br />
• Weather sealed using a Sika-Trocal Type S 1.5 (1.5mm x 1100mm) water proof membrane mechanically fixed to the roof system<br />
using Trocal Metal Discs and Fasteners secured in place by the 6.3 x 175mm fastec CR10 fluro carbon coated screws mentioned<br />
above.<br />
• The 150mm insulation roof system tested incorporated a 150 x 200mm external edge flashing and a 300 x 300mm internal<br />
roof/wall 1.6mm galvanised steel flashing.<br />
• The roof system was tested in combination with LPCB approved PIR core wall panels.<br />
Recticel Insulation Products / Recticel N.V<br />
Enterprise way, Meir Park, Stoke-On-Trent ST3 7UN, United Kingdom<br />
Tel: +44 (0)1782 590470 • Fax: +44(0)1782 590499<br />
E-mail: enquiries@recticelinsulation.co.uk • Website: www.recticelinsulation.com<br />
Recticel N.V<br />
Tramstraat 6, B-8560, Wevelgem, Belgium<br />
Certificate No: 968a to LPS 1181: Part 1: Issue 1<br />
30 20 Nov 2011
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Product Name<br />
Roofing system incorporating Eurothane<br />
Silver<br />
Roofing system incorporating Powerdeck<br />
F<br />
Specification<br />
Thickness<br />
(System)<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
65 - 155 - - EXT-<br />
B<br />
65 - 155 - - EXT-<br />
B<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
PIR 968a/01<br />
PIR 968a/02<br />
Notes:<br />
1. LPCB Ref 968a/01 Eurothane Silver Mechanically Fixed Insulated metal deck system is approved to LPS 1181-1 as a built up roof<br />
system of the following configuration:<br />
· Corus D35 Roof Decking (0.7mm thick) or equivalent; deck panel lap joints stitched at 400mm centres.<br />
· Eurothane Silver foil faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 2.4m x 1.2m sheets (approved at<br />
30mm to 120mm thick) the boards through fixed to deck using BS 4.8 x 130mm screws & SFS Isotak RP75 x 30 tube washers<br />
with a 183mm PVC disk sitting on top of the PIR insulation at 600mm centres<br />
· Weather sealed using Fatra Fatrafol 810AA (1.5mm x 1300mm) Single ply membrane having its lap joint’s hot air welded in<br />
accordance with manufacturer's recommendations, or equivalent single ply water proof membrane, the membrane is bonded to<br />
the 183mm PVC disks using Fatra FF855 adhesive, brush applied.<br />
· The roof system was tested in combination with LPCB approved PIR core wall panels.<br />
2. LPCB Ref 968a/02 Powerdeck F Mechanically Fixed Insulated metal deck system is approved to LPS 1181-1 as a built up roof<br />
system of the following configuration:<br />
· Corus D35 Roof Decking (0.7mm thick) or equivalent; deck panel lap joints stitched at 400mm centres.<br />
· Powerdeck F glass tissue faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 1.2m x 0.6m sheets (approved<br />
at 30mm to 120mm thick) the boards through fixed to deck using BS 4.8 x 130mm screws & SFS Isotak RP75 x 30 tube washers<br />
with a 183mm PVC disk sitting on top of the PIR insulation at 600mm centres<br />
· Weather sealed using Fatra Fatrafol 810AA (1.5mm x 1300mm) Single ply membrane having its lap joint’s hot air welded in<br />
accordance with manufacturer's recommendations, or equivalent single ply water proof membrane, the membrane is bonded to<br />
the 183mm PVC disks using Fatra FF855 adhesive, brush applied.<br />
· The roof system was tested in combination with LPCB approved PIR core wall panels.<br />
Rockwool Limited<br />
Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom<br />
Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302<br />
E-mail: info@rockwool.co.uk • Website: www.rockwool.co.uk<br />
Certificate No: 022g to LPS1181: Part 1: Issue 1.1<br />
Product Name<br />
Specification<br />
System<br />
Thickness<br />
(mm) (1)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
(2)<br />
Core<br />
Material<br />
Hardrock DD roof board system 210 120 120 EXT- Stone wool 022g/01<br />
A120<br />
100 - 135 60 60 EXT-A60 Stone wool<br />
100 - 210 - - EXT-B Stone wool<br />
140 - 205 90 90 EXT-A90 Stone wool<br />
Hardrock DD SPA roof board<br />
210 120 120 EXT- Stone wool 022g/02<br />
system<br />
A120<br />
100 - 135 60 60 EXT-A60 Stone wool<br />
100 - 210 - - EXT-B Stone wool<br />
140 - 205 90 90 EXT-A90 Stone wool<br />
DuoRock roof board system 100 - 210 60 60 EXT-A60 Stone wool 022g/03<br />
100 - 210 - - EXT-B Stone wool<br />
Cert.<br />
No.<br />
Notes:<br />
1. Roof board system LPCB Ref No. 022g/01 & LPCB Ref No. 022g/03: Mechanically fastened Sarnafil single ply type S327-12EL<br />
(1.2mm thickness), external weather proof membrane (or alternative membrane less than 3.5 kg/m² e.g. PVC, Chlorinated PE, Butyl<br />
Rubber with welded seams);<br />
Comprising of two layers of Rockwool roofing board with staggered joints (100mm minimum stagger for fire resistance up to 90<br />
minutes and 300mm stagger for 2 hours fire resistance), vapour control layer and 0.7mm thickness 35mm deep profile steel metal<br />
deck.<br />
Roof board system LPCB Ref No. 022g/02: Sarnafil single ply external weather proof membrane type G410-12EL (1.2mm thickness),<br />
fully adhered to Hardrock DD SPA roof board system with Sarnifil Adhesive(or Rockwool approved alternative adhesive/membrane<br />
combination, with a membrane material less than 3.5 kg/m² e.g. PVC, Chlorinated PE, Butyl Rubber with welded seams); comprising<br />
20 Nov 2011 31
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
of two layers of Rockwool roofing board with staggered joints (100mm minimum stagger for fire resistance up to 90 minutes and<br />
300mm stagger for 2 hours fire resistance), vapour control layer and 0.7mm thickness 35mm deep profile steel metal deck.<br />
Roof Board System LPCB Ref No 022g/01, 022g/02 & 022g/03 Hardrock DD, Hardrock DD SPA and DuoRock roofing boards are<br />
also available and approved in cut-to-fall tapered options, the relevant minimum & maximum system thickness and staggered joints<br />
shall apply as detailed above.<br />
2. For EXT-A fire resistance grading, the test construction was tested unloaded. However, deflection of the roof did not exceed the<br />
allowable limits set out in BS 476: Part 20: 1987 for loadbearing horizontal elements.<br />
3. Decking side laps were stitched at 450mm centres. The built up roofing system was tested with Eurobond Stone wool core sandwich<br />
wall panels.<br />
Ruukki Polska Sp. z.o.o<br />
ul Jaktorowska 13, 96-300, Zyradow, Poland<br />
Tel: 0121 704 7300 • Fax: 0121 711 9712<br />
E-mail: gareth.ellison@ruukki.com • Website: www.ruukki.com<br />
Certificate No: 1052a to LPS 1181-1<br />
Product<br />
Name<br />
SP2B UK<br />
(wall panel)<br />
SP2C UK<br />
(ceiling<br />
panel)<br />
SP2D UK<br />
(wall panel)<br />
SP2E UK<br />
(wall panel)<br />
Specification<br />
Thickness (mm)<br />
Wall panel<br />
orientation (H/V)<br />
(Note 1)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(mins)<br />
LPS1181 -<br />
1 Grade<br />
Core<br />
Material<br />
Cert. No.<br />
100 H 61/34 EXT-A30 PIR 1052a/01<br />
100 V 61/30 EXT-A30 PIR<br />
40, 60, 80 and 100 H/V - EXT-B PIR<br />
80 and 100 H 53/17 EXT-A15 PIR<br />
120/80, 140/100 and<br />
- 63/37 EXT-A30 PIR 1052a/02<br />
210/170<br />
80/40, 100/60, 120/80,<br />
- - EXT-B PIR<br />
140/100 and 210/170<br />
80/40, 100/60, 120/80,<br />
140/100 and 210/170<br />
- 91/19 EXT-A15 PIR<br />
100 V 50/22 EXT-A15 PIR 1052a/03<br />
60, 80 and 100 H/V - EXT-B PIR<br />
120, 160, 180 and 200 H/V - EXT-B PIR 1052a/04<br />
120, 160, 180 and 200 V 46/25 EXT-A15 PIR<br />
Notes:<br />
1. Wall panel orientatin, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
2. LPCB Ref 1052a/02 EXT-B grade ceiling panels, joints shall be stitched on the external face using 4.9 x 19mm zinc coated<br />
carbon steel self drilling fasteners at nominal 300mm centres.<br />
3. LPCB Ref 1052a/02 EXT-A15 grade 80/40, 100/60, 120/80, 140/100 and 210/170 ceiling panels were fire resistance tested with<br />
an imposed load of 24kg/m2. The maximum unsupported span shall be limited to 2.0m between supports and the panel joints<br />
shall be stitched on the external face using 4.9 x 19mm zinc coated carbon steel self drilling fasteners at nominal 300mm centres.<br />
4. LPCB Ref 1052a/02 EXT-A30 grade 120/80, 140/100 and 210/170 ceiling panels were fire resistance tested with an imposed<br />
load of 32kg/m2. The maximum unsupported span shall be limited to 2.0m between supports and the panel joints shall be stitched<br />
on the external face using 4.9 x 19mm zinc coated carbon steel self drilling fasteners at nominal 300mm centres.<br />
SpeedDeck Building Systems Limited<br />
Oaksmere Business Park, Yaxley, Eye, Suffolk IP23 8BW, United Kingdom<br />
Tel: +44 (0)1379 788166 • Fax: +44 (0)1379 788161<br />
E-mail: speeddeck@eleco.com • Website: www.eleco.co/speeddeck<br />
Certificate No: 738a to LPS 1181: Part 1<br />
Product Name<br />
SpeedDeck double skin roof<br />
system<br />
Specification<br />
System<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
180 - 220 - - EXT-<br />
B<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
Glass wool 738a/01<br />
32 20 Nov 2011
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Product Name<br />
Specification<br />
System<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
SpeedZip double skin roof system 180 - 220 - - EXT-<br />
B<br />
PP32 double skin roof system 180 - 220 - - EXT-<br />
B<br />
SpeedRoof double skin roof 180 - 220 - - EXTsystem<br />
B<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
Glass wool 738a/02<br />
Glass wool 738a/03<br />
Glass wool 738a/04<br />
Notes:<br />
1. LPCB Ref. 738a/01 SpeedDeck double skin roof system: external sheet may be 0.9mm 3004 grade embossed plain aluminium or<br />
0.9mm aluminium coated with a 25 micron PVdF or 30 micron ARS paint finish or 0.6mm or 0.7mm steel with a 200 micron PVC paint<br />
finish i.e. Corus HPS200 or Dobel 200XT outer skin and Walkliner inner skin.<br />
2. LPCB Ref. 738a/02 SpeedZip double skin roof system: 0.9mm aluminium with a stucco plain or 25 micron PVdF or 30 micron<br />
ARS paint finish outer skin and Walkliner inner skin.<br />
3. LPCB Ref. 738a/03 PP32 double skin roof system: 0.7mm steel trapezoidal 32mm profile with a Dobel 200XT 200 micron PVC paint<br />
finish outer skin and Walkliner inner skin, outer skin lap joints stitched at 450mm centres.<br />
4. LPCB Ref. 738a/04 SpeedRoof double skin roof system: 0.7mm steel profile with Corus HPS200, Dobel 200XT or Dobel Nova outer<br />
skin finish and Walkliner inner skin.<br />
ThyssenKrupp Steel Europe AG<br />
Hammerstrasse 11, D-57223 Kreuztal, Germany<br />
Tel: +49 (0)2723 599 1221 • Fax: +49 (0)2723 599 1219<br />
E-mail: export@tks-bau.thyssenkrupp.com • Website: www.thyssenkrupp-bausysteme.com<br />
www.thyssenkrupp-steel-europe.com<br />
Certificate No: 657a to LPS 1181: Part 1<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Specification<br />
Wall Panel<br />
Orienation<br />
(H/V)<br />
(See Note 1)<br />
Fire Resistance<br />
Integrity /<br />
Insualation<br />
LPS 1181-<br />
1<br />
Grade<br />
Core<br />
Material<br />
Hoesch isowand integral (wall 60 - 120 H/V - / - EXT-B PIR 657a/01<br />
panel)<br />
Hoesch isowand vario (wall panel) 60 - 140 H/V - / - EXT-B PIR 657a/02<br />
Hoesch isowelle (wall panel) 64 - 104 H/V - / - EXT-B PIR 657a/03<br />
Hoesch isorock integrad D (roof 95 - 155 - - / - EXT-B Mineral 657a/04<br />
panel)<br />
fibre<br />
Hoesch isowand vario (wall panel) 100 - 140 H 42 / 49 EXT-A30 PIR 657a/05<br />
80 - 140 H 32 / 24 EXT-A15 PIR<br />
80 - 140 V 61 / 26 EXT-A15 PIR<br />
Hoesch Thermodach (roof panel) 75 - 130 - - / - EXT-B PIR 657a/06<br />
Hoesch isodach integral (roof 75 - 155 - - / - EXT-B PIR 657a/07<br />
panel)<br />
Hoesch isodach mono (roof panel) 95 - 155 - - / - EXT-B PIR 657a/08<br />
Cert.<br />
No.<br />
Notes:<br />
1. Wall orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
2. LPCB Ref. No 657a/04 - Roof panel joints are held by use of an aluminium locking system and covered with a continuous joint cover,<br />
cover ledge <strong>part</strong> No. S33-052.<br />
3. LPCB Ref. No. 657a/05 - Wall panels are stitched on the internal face using 5.5 x 70mm stainless steel screws at 150mm centres.<br />
4. LPCB Ref. No. 547a/05 Grade EXT-A15 Wall panel joints are stitched on the external face with 4.2mm self tapping stainless steel<br />
screws and nominal 400mm centres.<br />
5. LPCB Ref. No. 657a/06, 657a/07 and 657a/05 - Roof panel joints are stitched on the external face with 4.8mm self tapping stainless<br />
steel scres and nominal 900mm centres.<br />
6. LPBC Ref. No. 657a/07 and 657a/08 - Roof panel jonts are held by use of a locking system and covered with a continuous joint<br />
cover.<br />
20 Nov 2011 33
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
Trimo d.d<br />
Prijatljeva 12, 8210 Trebnje, Slovenija<br />
Tel: 00386 73460200 • Fax: 0038 673460127<br />
E-mail: trimo@trimo.si • Website: www.trimo.eu<br />
UK Supplier<br />
Trimo UK Ltd, Unit 4 Willaston House, Crewe Road, Nantwich, Cheshire CW5 6NE, United Kingdom<br />
Tel: +44 (0) 1270 665303 • Fax: +44 (0) 1270 664294<br />
E-mail: trimo@trimo.org.uk • Website: www.trimo.org.uk<br />
Certificate No: 650b to LPS 1181: Part 1<br />
Product Name<br />
Specification<br />
System<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade Core Material Cert. No.<br />
Trimotherm FTV (wall panel) 100 - 150 95 95 EXT-A90 Mineral wool 650b/01<br />
Trimotherm SNV (ceiling panel) 100 98 95 EXT-A90 Mineral wool 650b/02<br />
Note:<br />
LPCB Ref. No. 650b/01 wall panels can be laid either horizontally or vertically.<br />
Xtratherm Limited<br />
Kells Road, Navan, Co. Meath, Ireland<br />
Tel: +353 46 906 6000 • Fax: +353 46 906 6090<br />
E-mail: info@xtratherm.com • Website: www.xtratherm.com<br />
Certificate No: 851a to LPS 1181: Part 1: Issue 1.1<br />
Product Name<br />
XT/FR-Alu Roof<br />
system<br />
XT/TR-Alu roof<br />
System<br />
XT/FR-MG Roof<br />
System<br />
XT/TR-MG Roof<br />
System<br />
Specification<br />
System<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
(minutes)<br />
Integrity<br />
Fire Resistance<br />
(minutes)<br />
Insulation<br />
Grade<br />
66 - 136 - - EXT-<br />
B<br />
66 - 136 - - EXT-<br />
B<br />
66 - 136 - - EXT-<br />
B<br />
66 - 136 - - EXT-<br />
B<br />
Insulation<br />
Material<br />
Cert.<br />
No.<br />
PIR 851a/01<br />
PIR<br />
PIR 851a/02<br />
PIR<br />
Notes:<br />
1. LPCB Ref 851a/01, the built-up roof system tested and approved consists of;<br />
• PVC Membrane laid in lengths across the width of the roof, mechanically fixed with hot-air welded lap joints.<br />
• 100mm XT/SP XT/FR-Alu or XT/TR-Alu PIR insulation boards (available and approved between 30mm to 100mm thick)<br />
mechanically fixed using a minimum of 6 fasteners per 2.4m x 1.2m board; each fastener incorporated a 50mm x 50mm square<br />
plate spreader washer. Boards laid in a break bond pattern.<br />
• 1mm gauge Vapour Control Layer - loose lay.<br />
• 0.7mm gauge, 35mm deep profiled metal deck with overlap side laps stitched at 400mm centres.<br />
2. LPCB Ref 851a/02, the built-up roof system tested and approved consists of;<br />
• PVC Membrane laid in lengths across the width of the roof, solvent welded to the PIR insulation boards with HA-C membrane<br />
adhesive at a rate of 250g/m2 and with solvent welded lap joints.<br />
• 100mm XT/SP XT/FR-MG or XT/TR-MG PIR insulation boards (available and approved between 30mm to 100mm thick)<br />
mechanically fixed using a minimum of 6 fasteners per 2.4m x 1.2m board; each fastener incorporated a 50mm x 50mm square<br />
plate spreader washer.<br />
• 1mm gauge Vapour Control Layer- loose lay.<br />
• 0.7mm gauge, 35mm deep profiled metal deck with overlap side laps stitched at 400mm centres.<br />
34 20 Nov 2011
PART 1: SECTION 2.1.2<br />
LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS<br />
3. LPCB Ref 851a/01 & 851a/02, the built-up roof systems were tested and approved in combination with a 150mm mineral wool cored<br />
sandwich panel wall elements.<br />
20 Nov 2011 35
PART 1: SECTION 2.1.3<br />
LPS 1181-2 SANDWICH PANELS OR BUILT-UP PANEL SYSTEMS USED INTERNALLY IN A BUILDING<br />
LPS 1181:Part 2 Requirements and tests for sandwich panels and built-up systems for use as internal<br />
constructions in buildings<br />
This standard determines the contribution to fire growth of sandwich panels and built-up cladding systems<br />
used internally within a building. Systems listed in this <strong>section</strong> are typically used for the construction of food<br />
factory clean rooms, cold store rooms/refrigerated spaces or room separation, other internal structure<br />
applications may also be applicable where insulated (acoustic or temperature controlled) spaces are<br />
specified. The structures are either self-supporting or supported by an external structure.<br />
The test is a large scale test comprising setting fire to an open-ended enclosure (approximately the size of a<br />
large domestic garage) from the sandwich panels or built-up cladding system. It evaluates the panels, the<br />
jointing methods and the supporting system including fixings, which gives an assessment of the true fire<br />
performance of the system which cannot be determined from traditional small scale reaction to fire tests, such<br />
as surface spread of flame or fire propagation tests.<br />
Products that have passed the test and have achieved LPCB approval are graded under the following<br />
designations:<br />
Requirements for internal applications<br />
GRADE<br />
Fire resistance<br />
Wall and ceiling lining test<br />
Thermal exposure<br />
Integrity (minutes) Insulation (minutes) Level Source<br />
INT-1 60 60 Enhanced Gas burner<br />
INT-2 30 30 Standard Timber crib<br />
INT-3 Standard Timber crib<br />
Brucha Ges.m.b.H<br />
Rusterstrasse 33, A-3451 Michelhausen, Michelhausen, Austria<br />
Tel: +43 (2275) 5878 1800 • Fax: +43 (2275) 5875 1804<br />
E-mail: office@brucha.at • Website: www.brucha.com<br />
Certificate No: 900b to LPS1181-2<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
WP-F (wall panel) 60, 80, 100,<br />
120, 150 &<br />
200<br />
WP-F (ceiling<br />
panel)<br />
60, 80, 100,<br />
120, 150 &<br />
200<br />
Maximum<br />
Unsupported<br />
Panel Span<br />
(m)<br />
Fire<br />
Resistance<br />
(min) Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
3.0 - - INT-3 Mineral Wool 900b/01<br />
3.5 - - INT-3 Mineral Wool 900b/02<br />
Notes:<br />
1. LPCB ref 900b/01 WP-F Wall panels to be installed with no external supports & the long edge joint in the vertical orientation only.<br />
2. LPCB ref 900b/01 & 900b/02 Wall and ceiling panel joints to be stitched on the internal face with 3.2 mm blind rivets at nominally<br />
300mm centres.<br />
3. LPCB ref 900b/02 WP-F Ceiling panels are supported by a hanger system consisting of.<br />
· A length of wire rope (4.0mm 6 x 7N 1AX) passed over and supported from a suitable load bearing frame.<br />
· An M10 turnbuckle with the rope secured using a ‘U bolt and clamp.<br />
· A length of M10 studding is passing through a hole which is drilled in the panel and secured on the internal surface with an 80mm<br />
diameter washer and domed head nut, this is further protected with a 0.55mm thick steel box (130mm-square x 30mm-deep with<br />
130mm x 30mm-flanges), lined with Promatect board and fixed using 3.2mm blind rivets.<br />
· The turn buckle is then adjusted to accommodate the weight of the panels.<br />
36 20 Nov 2011
PART 1: SECTION 2.1.3<br />
LPS 1181-2 SANDWICH PANELS OR BUILT-UP PANEL SYSTEMS USED INTERNALLY IN A BUILDING<br />
Eurobond Laminates Limited & Eurobond Doors Limited<br />
Wentloog Corporate Park, Wentloog, Cardiff CF3 2ER, United Kingdom<br />
Tel: + 44 (0)2920 776677 • Fax: + 44 (0)2920 369161<br />
E-mail: sales@eurobond.co.uk • Website: www.eurobond.co.uk<br />
Certificate No: 545c to LPS1181: Part 2: Issue 2<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Maximum<br />
Unsupported<br />
Panel Length<br />
(m)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Cert. No.<br />
Firemaster Wall Lite 75 3.00 30 30 INT-2 Mineral fibre 545c/01<br />
75 3.00 60 30 INT-2 Mineral fibre<br />
100 4.00 90 60 INT-1 Mineral fibre<br />
100 4.50 60 60 INT-1 Mineral fibre<br />
100 4.50 60 60 INT-1 Mineral fibre<br />
100 5.50 30 30 INT-2 Mineral fibre<br />
125 4.00 90 60 INT-1 Mineral fibre<br />
125 4.50 60 60 INT-1 Mineral fibre<br />
125 5.50 30 30 INT-2 Mineral fibre<br />
150 5.00 120 90 INT-1 Mineral fibre<br />
150 5.50 60 60 INT-1 Mineral fibre<br />
150 5.50 60 60 INT-1 Mineral fibre<br />
150 5.50 90 90 INT-1 Mineral fibre<br />
175 5.00 90 90 INT-1 Mineral fibre<br />
175 5.00 120 90 INT-1 Mineral fibre<br />
175 5.50 60 60 INT-1 Mineral fibre<br />
200 5.00 90 90 INT-1 Mineral fibre<br />
200 5.00 120 90 INT-1 Mineral fibre<br />
200 5.50 60 60 INT-1 Mineral fibre<br />
Firemaster Wall Extra 75 3.00 30 30 INT-2 Mineral fibre 545c/02<br />
75 3.00 60 60 INT-1 Mineral fibre<br />
100 5.50 90 90 INT-1 Mineral fibre<br />
100 5.50 120 120 INT-2 Mineral fibre<br />
100 6.00 60 60 INT-1 Mineral fibre<br />
125 5.50 90 90 INT-1 Mineral fibre<br />
125 5.50 120 120 INT-1 Mineral fibre<br />
125 6.00 60 60 INT-1 Mineral fibre<br />
125 7.50 30 30 INT-2 Mineral fibre<br />
150 7.5 60 60 INT-1 Mineral fibre<br />
150 7.5 120 120 INT-1 Mineral fibre<br />
150 7.50 90 90 INT-1 Mineral fibre<br />
175 7.50 60 60 INT-1 Mineral fibre<br />
175 7.50 90 90 INT-1 Mineral fibre<br />
175 7.50 120 120 INT-1 Mineral fibre<br />
Firemaster Ceiling Panel 75 6.00 - - INT-3 Mineral fibre 545c/03<br />
100 4.20 60 60 INT-1 Mineral fibre<br />
100 6.00 - - INT-3 Mineral fibre<br />
125 4.20 60 60 INT-1 Mineral fibre<br />
125 6.00 - - INT-3 Mineral fibre<br />
150 4.20 60 60 INT-1 Mineral fibre<br />
150 6.0 - - INT-3 Mineral fibre<br />
Firemaster Wall Ultima 150 7.50 240 240 INT-1 Mineral fibre 545c/05<br />
175 7.50 240 240 INT-1 Mineral fibre<br />
200 7.50 240 240 INT-1 Mineral fibre<br />
Notes:<br />
1. Grade INT-1 approved products have equal performance at Grade INT-2 and INT-3<br />
2. Grade INT-2 approved products have equal performance at Grade INT-3<br />
3. LPCB Ref No. 545c/02 - Where Eurobond 120 rock fibre insulation core is used in the 100mm thick panel the fire resistance insulation<br />
performance is limited to 90 minutes for maximum unsupported panel lengths of 5.5m<br />
4. LPCB Ref No. 545c/05 - 150mm and 175mm Firemaster Wall Ultima panel joints are to be stitched on both internal and external<br />
faces using 4.7mm diameter x 20mm long self-tapping screws at 300mm centres, the 200mm panel does not require stitching<br />
20 Nov 2011 37
PART 1: SECTION 2.1.3<br />
LPS 1181-2 SANDWICH PANELS OR BUILT-UP PANEL SYSTEMS USED INTERNALLY IN A BUILDING<br />
Excel Industries Ltd<br />
Maerdy Industrial Estate (South), Rhymney, Gwent NP22 5PY, United Kingdom<br />
Tel: +44 (0)1685 845200 • Fax: +44 (0)1685 844106<br />
E-mail: info@excelfibre.com • Website: www.excelfibre.com<br />
Certificate No: 721a to LPS 1181: Part 2: Issue 2<br />
Product Name<br />
Warmcel built-up wall<br />
panel system<br />
Warmcel built-up ceiling<br />
panel system<br />
Specification<br />
Thickness<br />
(mm)<br />
System<br />
thickness -<br />
293 (note 1)<br />
System<br />
thickness -<br />
329.2 (note 2)<br />
Maximum<br />
Unsupported<br />
Panel Length<br />
Self<br />
supporting<br />
system on<br />
fixed footplate<br />
(note 3)<br />
Supported on<br />
wall panel<br />
system (note<br />
4)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
- - INT-3 Warmcel<br />
500<br />
cellulose<br />
fibre<br />
- - INT-3 Warmcel<br />
500<br />
cellulose<br />
fibre<br />
Cert.<br />
No.<br />
721a/01<br />
721a/02<br />
Notes:<br />
1. LPCB Ref. No. 721a/01 wall panel build specification<br />
Inner layer - 2 off layers (staggered joints) 10mm Sasmox Fire resistant & acoustic panel<br />
Core - 245mm void created by timber I beams at a maximum of 600mm centres, void filled with<br />
Warmcel 500 full fill insulation dry fill at 45-55kg/m 3 density<br />
Outer layer - 2 off layers (staggered joints) 10mm Sasmox Fire resistant & acoustic panel<br />
Alternative panel types for outer and inner layers - two layers of 10mm Xella Fermacell or 12.5mm Gyproc Fireline wallboard or<br />
12.5mm Lafarge Firecheck wallboard<br />
2. LPCB Ref. No. 721a/02 ceiling panel build specification<br />
Inner layer - 2 off layers (staggered joints) 10mm Sasmox Fire resistant & acoustic panel<br />
Core - 300mm void created by timber I beams at a maximum of 600mm centres, void filled with Warmcel 500 full fill insulation dry fill<br />
at 45-55kg/m 3 density<br />
Outer layer - single layer 9.2mm panel vent board<br />
Alternative panel types for inner layers - two layers of 10mm Xella Fermacell or 12.5mm Gyproc Fireline wallboard or 12.5mm Lafarge<br />
Firecheck wallboard<br />
3. No external supports for wall panel system used during test, maximum spans used during test, 10 metre long x 3 metre high.<br />
4. Ceiling panel system supported around perimeter on wall panel system only, no additional external supports used. Maximum spans<br />
used during test, 10 metre long x 4.5 metre wide.<br />
Paneltex Limited<br />
Kingston International Business Park, Somerden Road, Kingston-upon-Hull HU9 5PE, United Kingdom<br />
Tel: 01482 787236 • Fax: 01482 787238<br />
E-mail: sales@paneltex.co.uk • Website: www.paneltex.co.uk<br />
Certificate No: 993a to LPS 1181 Part 2: Issue 2.0<br />
Product Name<br />
Paneltex Fireproof<br />
Coldstore (wall and<br />
ceiling panel system)<br />
Specification Maximum Fire resistance (minutes) Grade Core Cert.<br />
Thickness (mm) system size Integrity/Insulation<br />
Material No.<br />
165 See Note 2 - / - INT-3 PIR 993a/01<br />
Notes:<br />
1. LPCB Ref 993a/01 Paneltex Fireproof Coldstore wall and ceiling panel systems to be installed with no external supports, the wall<br />
panels have the long edge joint in the horizontal orientation.<br />
2. LPCB Ref 993a/01 The maximum internal length and width of the Paneltex Fireproof Coldstore system shall not exceed 14.277m x<br />
3.584m.<br />
38 20 Nov 2011
PART 1: SECTION 2.1.3<br />
LPS 1181-2 SANDWICH PANELS OR BUILT-UP PANEL SYSTEMS USED INTERNALLY IN A BUILDING<br />
Trimo d.d<br />
Prijatljeva 12, 8210 Trebnje, Slovenija<br />
Tel: 00386 73460200 • Fax: 0038 673460127<br />
E-mail: trimo@trimo.si • Website: www.trimo.eu<br />
UK Supplier<br />
Trimo UK Ltd, Unit 4 Willaston House, Crewe Road, Nantwich, Cheshire CW5 6NE, United Kingdom<br />
Tel: +44 (0) 1270 665303 • Fax: +44 (0) 1270 664294<br />
E-mail: trimo@trimo.org.uk • Website: www.trimo.org.uk<br />
Certificate No: 650c to LPS 1181: Part 2: Issue 2<br />
Product Name<br />
Trimotherm<br />
FTV (wall<br />
panel)<br />
Specification<br />
Thickness<br />
(mm)<br />
Specification<br />
Orientation<br />
of<br />
Long Edges<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
100 Horizontal 30 30 7.25 INT-2 Mineral<br />
wool<br />
100 Horizontal 60 60 7.25 INT-2 Mineral<br />
wool<br />
100 Horizontal 90 90 5.60 INT-2 Mineral<br />
wool<br />
100 Vertical 30 30 7.25 INT-2 Mineral<br />
wool<br />
100 Vertical 60 60 7.25 INT-2 Mineral<br />
wool<br />
100 Vertical 90 90 5.60 INT-2 Mineral<br />
wool<br />
120 Horizontal 30 30 8.00* INT-2 Mineral<br />
wool<br />
120 Horizontal 60 60 8.00* INT-2 Mineral<br />
wool<br />
120 Horizontal 90 90 8.00* INT-2 Mineral<br />
wool<br />
120 Horizontal 120 120 8.00 INT-2 Mineral<br />
wool<br />
120 Vertical 30 30 7.25 INT-2 Mineral<br />
wool<br />
120 Vertical 60 60 7.25 INT-2 Mineral<br />
wool<br />
120 Vertical 90 90 5.60 INT-2 Mineral<br />
wool<br />
120 Vertical 120 120 4.00 INT-2 Mineral<br />
wool<br />
150 Horizontal 30 30 8.00* INT-2 Mineral<br />
wool<br />
150 Horizontal 60 60 8.00* INT-2 Mineral<br />
wool<br />
150 Horizontal 90 90 8.00* INT-2 Mineral<br />
wool<br />
150 Horizontal 120 120 8.00 INT-2 Mineral<br />
wool<br />
150 Horizontal 180 180 4.00 INT-2 Mineral<br />
wool<br />
150 Vertical 30 30 7.25 INT-2 Mineral<br />
wool<br />
150 Vertical 60 60 7.25 INT-2 Mineral<br />
wool<br />
150 Vertical 90 90 6.00 INT-2 Mineral<br />
wool<br />
150 Vertical 120 120 5.50 INT-2 Mineral<br />
wool<br />
150 Vertical 180 180 4.00 INT-2 Mineral<br />
wool<br />
Cert.<br />
No.<br />
650c/01<br />
20 Nov 2011 39
PART 1: SECTION 2.1.3<br />
LPS 1181-2 SANDWICH PANELS OR BUILT-UP PANEL SYSTEMS USED INTERNALLY IN A BUILDING<br />
Note:<br />
1. LPCB Ref. No. 6"50c/01 - unsupported spans marked *, span can be extended to 10.4m in respect of the length of the panel in<br />
horizontal laid orientation only.<br />
40 20 Nov 2011
PART 1: SECTION 2.1.4<br />
LPS 1181-3 (DRAFT) CLADDING USED IN POD CONSTRUCTION<br />
LPS 1181: Part 3 (Draft) Requirements and tests for factory produced room modules (PODS) and building<br />
system modules<br />
‘PODS’ are prefabricated units forming a room containing all structural elements and linings and may include<br />
services and fittings. This <strong>section</strong> covers PODS constructed of sandwich panels walls and/or ceilings.<br />
For units listed in this <strong>section</strong>, the wall and ceiling construction has been tested to LPS 1181:Part 3 (Draft).<br />
The testing does not assess the structural performance of the POD under test nor the effect of doors or<br />
windows within the structure.<br />
Portakabin Ltd<br />
New lane, Huntington, , York YO32 9PT, United Kingdom<br />
Tel: 01904 611655 • Fax: 01904 611644<br />
E-mail: sales@portakabin.co.uk • Website: www.portakabin.co.uk<br />
Certificate No: 592a(2) to LPS1181 Part 3<br />
Product Name<br />
ULTIMA Building System Building<br />
Module (wall)<br />
ULTIMA Building System Building<br />
Module (ceiling)<br />
ULTIMA Building System Building<br />
Module (roof)<br />
Specification<br />
Sandwich panel<br />
thickness only<br />
76mm & 89mm<br />
thick<br />
Fire Resistance<br />
(min)<br />
Integrity<br />
Fire Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
60 15 A PUR 592a/03<br />
47mm thick 60 60 A PUR 592a/04<br />
110mm thick - - B PUR 592a/05<br />
Notes:<br />
1. LPCB Ref. No. 592a/03, 592a/04 & 592a/05 Test specimen conformed to LPS1181 size requirements, except width was only 3.6m,<br />
the maximum width possible for the module.<br />
2. LPCB Ref. No. 592a/03 Wall panels laid with long joints in the vertical orientation.<br />
3. LPCB Ref. No. 592a/04 The test specimen for the ceiling fire resistance test was a combined ceiling and floor construction<br />
4. LPCB Ref. No. 592a/03 Wall inner surface lining 1x layer 12.5mm thick Gyproc Fireline Duplex, Lafarge GTEC Fire V or Knauf<br />
Fireshield Plasterboard with Renolit Minster PVC innerface lining.<br />
5. LPCB Ref. No. 592a/04 & 592a/05 Inner surface: interior polyester steel.<br />
6. LPCB Ref. No. 592a/03, 592a/04 & 592a/05 No assessment has been made of the structural performance of the module, or of the<br />
inclusion of windows and doors. Therefore there has been no evaluation of the performance should the fire break through a window<br />
or door.<br />
7. LPCB Ref. No. 592a/03, 592a/04 & 592a/05 Test Specimen short wall was 89mm thick and the long walls were 76mm thick.<br />
Yorkon Limited<br />
New Lane, Huntington, York YO32 9PT, United Kingdom<br />
Tel: +44 (0)1904 610990 • Fax: +44 (0)1904 610880<br />
E-mail: contact@yorkon.co.uk • Website: www.yorkon.co.uk<br />
Certificate No: 592a(1) to LPS 1181: Part 3<br />
Yorkon Room and Building Modules<br />
Product Name<br />
Specification Fire<br />
Fire Grade Core Cert. No.<br />
(sandwich panel<br />
thickness only)<br />
(mm)<br />
Resistance<br />
(min)<br />
Integrity<br />
Resistance<br />
(min)<br />
Insulation<br />
Material<br />
Yorkon Room Module (wall) 70 60 15 A PUR 592a/01<br />
Yorkon Room Module (ceiling) 47 60 60 A PUR 592a/02<br />
Yorkon Building Module (wall) 76 and 89 60 15 A PUR 592a/03<br />
Yorkon Building Module (ceiling) 47 60 60 A PUR 592a/04<br />
Yorkon Building Module (roof) 110 - - B PUR 592a/05<br />
20 Nov 2011 41
PART 1: SECTION 2.1.4<br />
LPS 1181-3 (DRAFT) CLADDING USED IN POD CONSTRUCTION<br />
Notes:<br />
1. LPCB Ref. No. 592a/01, 592a/02, 592a/03, 592a/04 & 592a/05 Test specimen conformed to LPS1181 size requirements, except<br />
width was only 3.6m, the maximum width possible for the module.<br />
2. LPCB Ref. No. 592a/01 & 592a/03 Wall panels laid with long joints in the vertical orientation.<br />
3. LPCB Ref. No. 592a/01 Wall inner surface lining 1x layer 15mm thick Gyproc Fireline Duplex, Lafarge GTEC Fire V or Knauf<br />
Fireshield taper edge plasterboard<br />
4. LPCB Ref. No. 592a/02 Ceiling inner surface lining 2 layers 15mm thick Gyproc Fireline Plasterboard 83mm below lower surface of<br />
PUR sandwich panel<br />
5. LPCB Ref. No. 592a/02 & 592a/04 The test specimen for the ceiling fire resistance test was a combined ceiling and floor construction<br />
6. LPCB Ref. No. 592a/03 Wall inner surface lining 1x layer 12.5mm thick Gyproc Fireline Duplex, Lafarge GTEC Fire V or Knauf<br />
Fireshield taper edge plasterboard.<br />
7. LPCB Ref. No. 592a/04 & 592a/05 Inner surface: interior polyester steel<br />
8. LPCB Ref. No. 592a/01, 592a/02, 592a/03, 592a/04 & 592a/05 No assessment has been made of the structural performance of the<br />
module, or of the inclusion of windows and doors. Therefore there has been no evaluation of the performance should the fire break<br />
through a window or door.<br />
9. LPCB Ref. No. 592a/03, 592a/04 & 592a/05 Test Specimen short wall was 89mm thick and the long walls were 76mm thick<br />
42 20 Nov 2011
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
LPS 1208: LPCB test and performance requirements for walls, cavity barriers, floors and roofs defines the test<br />
and performance requirements to satisfy the fire resistance requirements for com<strong>part</strong>mentation given in the<br />
LPC Design Guide for Fire Protection of Buildings: 2000.<br />
Products for use in the following elements of construction fall within the scope of LPS 1208:<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Loadbearing com<strong>part</strong>ment walls<br />
Non-loadbearing com<strong>part</strong>ment walls and <strong>part</strong>itions<br />
External walls<br />
Curtain walls<br />
Cavity barriers<br />
Roofs where fire resistance is required (loadbearing and non-loadbearing)<br />
Loadbearing com<strong>part</strong>ment floors<br />
Insulated panels used for enclosing production and storage areas in food factories<br />
Note: Unless otherwise stated in individual listings, elements of construction have not been approved for load<br />
bearing capacity.<br />
ArcelorMittal Construction Belgium<br />
Zone Industrielle de Martinrou, 21b rue de Berlaimont, Fleurus, Belgium<br />
Tel: +32 (0) 718 70540 • Fax: +32 (0) 718 70541<br />
Website: www.arcelormittal.com<br />
Certificate No: 737a to LPS 1208<br />
Promistyl Feu (Wall panel)<br />
Product Specification<br />
Name Thickness (mm)<br />
Promistyl<br />
Feu 3003<br />
(Wall panel)<br />
Promistyl<br />
Feu 3506<br />
(Wall panel)<br />
Fire Resistance<br />
(min) Integrity /<br />
Insulation (BS 476:<br />
Part 22)<br />
Wall Panel<br />
Orientation<br />
(H/V) (note 1)<br />
Max.<br />
Unsupported<br />
span (m)<br />
Grade<br />
Core<br />
material<br />
120 - 200 120/120 H 4.2 FR120 Mineral<br />
fibre<br />
120 - 200 120/120 V 4.0 FR120 Mineral<br />
fibre<br />
120 - 200 30/30 H/V 7.5 FR30 Mineral<br />
fibre<br />
120 - 200 60/60 H 7.5 FR60 Mineral<br />
fibre<br />
120 - 200 60/60 V 6.2 FR60 Mineral<br />
fibre<br />
120 - 200 90/60 H 5.6 FR90 Mineral<br />
fibre<br />
120 - 200 90/90 V 4.1 FR90 Mineral<br />
fibre<br />
80 - 100 120/60 V 4.0 FR60 Mineral<br />
fibre<br />
80 - 100 30/30 V 6.6 FR30 Mineral<br />
fibre<br />
80 - 100 60/60 V 4.0 FR60 Mineral<br />
fibre<br />
80 - 100 90/60 V 4.0 FR60 Mineral<br />
fibre<br />
120 - 200 30/30 H 7.5 FR30 Mineral<br />
fibre<br />
120 - 200 60/60 H 4.0 FR60 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
737a/01<br />
737a/02<br />
Note:<br />
1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
20 Nov 2011 43
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
2. LPCB ref No. 737a/01 & 737a/02 Promistyl Feu 3003 & 3506 wall panels are available with 0.5 to 0.63mm smooth, ribbed or grooved<br />
internal steel facing and 0.5 to 0.75mm smooth, ribbed, micro-ribbed or grooved external external steel facing.<br />
Eurobond Laminates Limited & Eurobond Doors Limited<br />
Wentloog Corporate Park, Wentloog, Cardiff CF3 2ER, United Kingdom<br />
Tel: + 44 (0)2920 776677 • Fax: + 44 (0)2920 369161<br />
E-mail: sales@eurobond.co.uk • Website: www.eurobond.co.uk<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
Firemaster Wall Extra<br />
Product Thickness<br />
Name (mm)<br />
Firemaster<br />
Wall Extra<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Wall Panel<br />
Orientation<br />
(V/H) *<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
75 30/30 V or H 3.0 FR30 Mineral<br />
Fibre<br />
75 60/60 V or H 3.0 FR60 Mineral<br />
fibre<br />
100 120/120 V or H 5.5 FR120 Mineral<br />
fibre<br />
100 120/90 V or H 5.5 FR90 Mineral<br />
fibre<br />
100 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
100 60/60 V or H 6.0 FR60 Mineral<br />
fibre<br />
100 90/90 V or H 5.5 FR90 Mineral<br />
fibre<br />
125 120/120 V or H 5.5 FR120 Mineral<br />
fibre<br />
125 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
125 60/60 V or H 6.0 FR60 Mineral<br />
fibre<br />
125 90/90 V or H 5.5 FR90 Mineral<br />
fibre<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
150 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
150 60/60 V or H 7.5<br />
FR60 Mineral<br />
7.5<br />
fibre<br />
150 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
175 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
175 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
175 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
200 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
200 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
200 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
200 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/01<br />
Note:<br />
* Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel.<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
44 20 Nov 2011
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Firemaster Ceiling Panel<br />
Product Thickness<br />
Name (mm)<br />
Firemaster<br />
Ceiling Panel<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Wall Panel<br />
Orientation<br />
(V/H)<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
100 60/60 - 4.2 FR60 Mineral<br />
fibre<br />
125 60/60 - 4.2 FR60 Mineral<br />
fibre<br />
150 60/60 - 4.2 FR60 Mineral<br />
fibre<br />
150 120/120 - 3.0 FR120 Mineral<br />
Fibre (note<br />
2)<br />
150 120/120 - 3.5 FR120 Mineral<br />
fibre<br />
150 60/60 - 6.0 FR60 Mineral<br />
fibre<br />
150 90/90 - 4.5 FR90 Mineral<br />
fibre (note<br />
2)<br />
150 90/90 - 4.7 FR90 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/02<br />
545a/12<br />
Note:<br />
1. LPCB ref 545a/12 - Ceiling panels to be stitched on both internal and external faces using 3.8mm diameter x 16mm long stainless<br />
steel rivets or 4.7mm diameter x 20mm long steel stitching screws at 300mm centres.<br />
2. Tervol DP-LX 12 stone mineral wool insulation core.<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
Firemaster Wall Lite<br />
Product Thickness<br />
Name (mm)<br />
Firemaster<br />
Wall Lite<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Wall Panel<br />
Orientation<br />
(V/H) *<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
75 30/30 V or H 3.0 FR30 Mineral<br />
fibre<br />
75 60/30 V or H 3.0 FR30 Mineral<br />
fibre<br />
100 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
100 60/60 V or H 4.5 FR60 Mineral<br />
fibre<br />
100 90/60 V or H 4.0 FR60 Mineral<br />
fibre<br />
125 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
125 60/60 V or H 4.5 FR60 Mineral<br />
fibre<br />
125 90/60 V or H 4.0 FR60 Mineral<br />
fibre<br />
150 120/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
150 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
150 60/60 V or H 5.5 FR60 Mineral<br />
fibre<br />
150 90/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
175 120/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
175 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
175 60/60 V or H 5.5 FR60 Mineral<br />
fibre<br />
175 90/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
200 120/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/03<br />
20 Nov 2011 45
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Product<br />
Name<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Wall Panel<br />
Orientation<br />
(V/H) *<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
200 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
200 60/60 V or H 5.5 FR60 Mineral<br />
fibre<br />
200 90/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
Note:<br />
* Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel.<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
Europanel Extra (wall panel)<br />
Product<br />
Name<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Europanel<br />
Extra (wall<br />
panel)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Maximum<br />
Unsupported<br />
Span(m)<br />
Grade<br />
Core<br />
Material<br />
75 30/30 V or H 3.0 FR30 Mineral<br />
fibre<br />
75 60/60 V or H 3.0 FR60 Mineral<br />
fibre<br />
100 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
100 60/60 V or H 6.0 FR60 Mineral<br />
fibre<br />
125 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
125 60/60 V or H 6.0 FR60 Mineral<br />
fibre<br />
125 90/90 V or H 5.5 FR90 Mineral<br />
fibre<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
150 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
150 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
150 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
175 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
175 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
175 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
200 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
200 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
200 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
200 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/05<br />
Note:<br />
* Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel.<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
46 20 Nov 2011
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Europanel Premier (wall panel)<br />
Product<br />
Name<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Europanel<br />
Premier (wall<br />
panel)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Maximum<br />
Unsupported<br />
span (m)<br />
Grade<br />
Core<br />
Material<br />
75 30/30 V or H 3.0 FR30 Mineral<br />
fibre<br />
75 60/60 V or H 3.0 FR60 Mineral<br />
fibre<br />
100 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
100 60/60 V or H 6.0 FR60 Mineral<br />
fibre<br />
125 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
125 60/60 V or H 6.0 FR60 Mineral<br />
fibre<br />
125 90/90 V or H 5.5 FR90 Mineral<br />
fibre<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
150 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
150 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
150 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
175 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
175 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
175 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
200 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
200 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
200 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
200 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/06<br />
Note:<br />
* Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel.<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
Europanel Lite (wall panel)<br />
Product<br />
Name<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Europanel<br />
Lite (wall<br />
panel)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
75 30/30 V or H 3.0 FR30 Mineral<br />
fibre<br />
75 60/30 V or H 3.0 FR30 Mineral<br />
fibre<br />
100 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
100 60/30 V or H 4.5 FR30 Mineral<br />
fibre<br />
125 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
125 60/60 V or H 4.5 FR60 Mineral<br />
fibre<br />
125 90/60 V or H 4.0 FR60 Mineral<br />
fibre<br />
150 120/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/07<br />
20 Nov 2011 47
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Product<br />
Name<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
150 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
150 60/60 V or H 5.5 FR60 Mineral<br />
fibre<br />
150 90/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
175 120/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
175 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
175 60/60 V or H 5.5 FR60 Mineral<br />
fibre<br />
175 90/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
200 120/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
200 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
200 60/60 V or H 5.5 FR60 Mineral<br />
fibre<br />
200 90/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
Note:<br />
* Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel.<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
Rockspan Extra (wall panel)<br />
Product<br />
Name<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Rockspan<br />
Extra (wall<br />
panel)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
75 30/30 V or H 3.0 FR30 Mineral<br />
fibre<br />
75 60/60 V or H 3.0 FR60 Mineral<br />
fibre<br />
100 120/120 V or H 5.5 FR120 Mineral<br />
fibre<br />
100 120/90 V or H 5.5 FR90 Mineral<br />
fibre<br />
100 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
100 60/60 V or H 6.0 FR60 Mineral<br />
fibre<br />
100 90/90 V or H 5.5 FR90 Mineral<br />
fibre<br />
125 120/120 V or H 5.5 FR120 Mineral<br />
fibre<br />
125 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
125 60/60 V or H 6.0 FR60 Mineral<br />
fibre<br />
125 90/90 V or H 5.5 FR90 Mineral<br />
fibre<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
150 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
150 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
150 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
175 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
175 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/08<br />
48 20 Nov 2011
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Product<br />
Name<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
175 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
200 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
200 30/30 V or H 7.5 FR30 Mineral<br />
fibre<br />
200 60/60 V or H 7.5 FR60 Mineral<br />
fibre<br />
200 90/90 V or H 7.5 FR90 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
Note:<br />
* Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel.<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
Rockspan Lite (wall panel)<br />
Product<br />
Name<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Rockspan<br />
Lite (wall<br />
panel)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
75 30/30 V or H 3.0 FR30 Mineral<br />
fibre<br />
75 60/30 V or H 3.0 FR30 Mineral<br />
fibre<br />
100 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
100 60/60 V or H 4.5 FR60 Mineral<br />
fibre<br />
100 90/60 V or H 4.0 FR60 Mineral<br />
fibre<br />
125 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
125 60/60 V or H 4.5 FR60 Mineral<br />
fibre<br />
125 90/60 V or H 4.0 FR60 Mineral<br />
fibre<br />
150 120/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
150 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
150 60/60 V or H 5.5 FR60 Mineral<br />
fibre<br />
150 90/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
175 120/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
175 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
175 60/60 V or H 5.5 FR60 Mineral<br />
fibre<br />
175 90/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
200 120/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
200 30/30 V or H 5.5 FR30 Mineral<br />
fibre<br />
200 60/60 V or H 5.5 FR60 Mineral<br />
fibre<br />
200 90/90 V or H 5.0 FR90 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/09<br />
Note<br />
* Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
20 Nov 2011 49
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Rockspan Ultima (wall panel)<br />
Product<br />
Name<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Rockspan<br />
Ultima (wall<br />
panel)<br />
Wall Panel<br />
Orientation<br />
(V/H) *<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
150 240/240 V or H 7.5 FR240 Mineral<br />
fibre<br />
175 240/240 V or H 7.5 FR240 Mineral<br />
fibre<br />
200 240/240 V or H 7.5 FR240 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/10<br />
Note:<br />
1. LPCB ref 545a/10 - Rockspan Ultima 150mm & 175mm thick wall panel joints to be stitched on both internal and external faces using<br />
4.7mm diameter x 20mm long self-tapping screws at 300mm centres, the 200mm panel does not require stitching.<br />
* Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel.<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
Firemaster Wall Ultima (wall panel)<br />
Product Name Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Firemaster Wall<br />
Ultima (wall<br />
panel)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
150 240/240 V or H 7.5 FR240 Mineral<br />
fibre<br />
175 240/240 V or H 7.5 FR240 Mineral<br />
fibre<br />
200 240/240 V or H 7.5 FR240 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/11<br />
Notes:<br />
1. LPBC Ref 545a/11 - Firemaster Wall Ultima wall panel joints to be stitched on both internal and external faces using 4.7mm diameter<br />
x 20mm long self-tapping screws at 300mm centres.<br />
* Wall panel orientation, vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel.<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
Rainspan<br />
Product Name<br />
Rainspan -<br />
Argeton<br />
terracotta tile<br />
system<br />
Rainspan -<br />
Linear system<br />
Rainspan -<br />
Parklex timber<br />
veneer system<br />
Rainspan -<br />
Rockpanel<br />
system<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
125 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 180/180 V or H 7.5 FR180 Mineral<br />
fibre<br />
125 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 180/180 V or H 7.5 FR120 Mineral<br />
fibre<br />
125 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 180/180 V or H 7.5 FR180 Mineral<br />
fibre<br />
125 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/13<br />
545a/14<br />
545a/15<br />
545a/16<br />
50 20 Nov 2011
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Product Name<br />
Rainspan -<br />
Corium brick slip<br />
system<br />
Rainspan -<br />
Generic timber<br />
system<br />
Rainspan -<br />
Clicktile steel<br />
tray system<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity/Insulation<br />
(min)<br />
Wall Panel<br />
Orientation<br />
(V/H)*<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 180/180 V or H 7.5 FR180 Mineral<br />
fibre<br />
125 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 180/180 V or H 7.5 FR180 Mineral<br />
fibre<br />
125 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 180/180 V or H 7.5 FR180 Mineral<br />
fibre<br />
125 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
150 120/120 V or H 7.5 FR120 Mineral<br />
fibre<br />
175 180/180 V or H 7.5 FR180 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
545a/17<br />
545a/18<br />
545a/19<br />
Notes:<br />
1. LPCB Ref 545a/13 to 545a/19 - Rainspan, the thickness specified relates to the insulated panel thickness only and does not include<br />
the facade system depth.<br />
* Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel.<br />
Euroclad Limited<br />
Wentloog Corporate Park, Wentloog Road, Cardiff CF3 2ER, United Kingdom<br />
Tel: +44 (0)2920 790722 • Fax: +44 (0)2920 793149<br />
E-mail: sales@euroclad.com • Website: www.euroclad.com<br />
Certificate No: 879b to LPS 1208: Issue 2<br />
Product Name<br />
Elite 51 (wall<br />
system)<br />
Elite 52 (wall<br />
system)<br />
Elite 53 (wall<br />
system)<br />
Elite 54 (wall<br />
system)<br />
Elite 55 (wall<br />
system)<br />
Elite 56 (wall<br />
system)<br />
Elite 57 (wall<br />
system)<br />
Elite 58 (wall<br />
system)<br />
Elite 60 (wall<br />
system)<br />
System<br />
Specification<br />
Thickness<br />
(mm)<br />
Wall panel<br />
orientation<br />
(H/V)<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Fire Resistance<br />
(minutes)<br />
Integrity /<br />
Insulation<br />
Grade<br />
Core<br />
material<br />
See note 2 V 3.0 240 / 30 FR30 Mineral<br />
Wool<br />
879b/09<br />
See note 2 V 3.0 240 / 30 FR30 Mineral 879b/10<br />
Wool<br />
See note 2 V 3.0 240 / 30 FR30 Mineral wool 879b/11<br />
See note 2 V 3.0 240 / 30 FR30 Mineral<br />
Wool<br />
See note 2 H 3.0 240 / 30 FR30 Mineral<br />
Wool<br />
See note 2 H 3.0 240 / 30 FR30 Mineral<br />
Wool<br />
See note 2 H 3.0 240 / 30 FR30 Mineral<br />
Wool<br />
See note 2 H 3.0 240 / 30 FR30 Mineral<br />
Wool<br />
See note 2 H 3.0 240 / 30 FR30 Mineral<br />
Wool<br />
Cert.<br />
No.<br />
879b/12<br />
879b/13<br />
879b/14<br />
879b/15<br />
879b/16<br />
879b/17<br />
Notes<br />
20 Nov 2011 51
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
1. Elite wall systems must have the sheeting rail spacing at a maximum of 2m & internal liner sheet side lap joints stitched using steel<br />
rivets at 300mm centres, the external liner must be fixed to the channels of the spacer system using self-drilling, self-tapping screws<br />
at nominal 400mm centres.<br />
2. The minimum permissible stone mineral wool thickness is 180mm, or for systems with horizontally laid external weather sheets where<br />
the eurobar spacer rails are vertical and the insulation in the core is supported by additional steel Z- <strong>section</strong> supports, and with a<br />
minimum density of the insulation of 33kg/m³ the minimum insulation thickness can be reduced to 150mm.<br />
3. Please refer to BRE Assessment Report CC248407 for approved alternative spacer systems, internal & external profiles, internal &<br />
external profile coatings and insulation cores for the Elite systems 51, 52, 53, 54, 55, 56, 57, 58 & 60.<br />
Hemsec Manufacturing Limited<br />
Stoney Lane, Rainhill, Prescot, Merseyside L35 9LL, United Kingdom<br />
Tel: +44 (0)151 426 7171 • Fax: +44 (0)151 493 1331<br />
E-mail: sales@hemsec.com • Website: www.hemsec.com<br />
Certificate No: 558a to LPS 1208: Issue 2<br />
Composite Panels<br />
Product Name<br />
Hemsec PIR Firecheck (wall<br />
panel)<br />
Hemsec PIR Firecheck (ceiling<br />
panel)<br />
Specification<br />
Thickness<br />
(mm)<br />
Maximum<br />
Unsupported<br />
span (m)<br />
Wall panel<br />
orientation<br />
(H/V)<br />
(note 1)<br />
BS 476:<br />
Part 22<br />
Fire<br />
Resistance<br />
(min) Integrity<br />
/<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
100 - 200 4.0 H 30/30 FR30 PIR 558a/16<br />
100 - 200 4.0 H 60/30 FR30 PIR<br />
100 - 200 4.0 V 30/30 FR30 PIR<br />
100 - 200 4.0 V 60/30 FR30 PIR<br />
175 - 200 4.0 H 30/30 FR30 PIR<br />
175 - 200 4.0 H 60/60 FR60 PIR<br />
175 - 200 4.0 V 60/60 FR60 PIR<br />
175 - 200 7.5 V 30/30 FR30 PIR<br />
100 - 200 7.5 - 60/30 FR30 PIR 558a/17<br />
175 - 200 4.5 - 60/60 FR60 PIR<br />
175 - 200 7.5 - 30/30 FR30 PIR<br />
Notes:<br />
PIR Firecheck panel:<br />
1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
2. The Hemsec LPS 1208 Model Specification document QCD: 064/1 relating to the PIR Firecheck wall and ceiling panels LPCB ref<br />
558a/16 and 558a/17 contains the critical components and specific stitching requirements needed for achieving LPCB compliant<br />
panel systems. Copies of the Model Specification are available on request, plese contact the Hemsec Sales De<strong>part</strong>ment.<br />
Certificate No: 558a to LPS 1208: Issue 2<br />
Hemsec SIP Firecheck<br />
Product Name Total<br />
system<br />
thickness<br />
(mm)<br />
Hemsec SIP<br />
Firecheck (wall<br />
system)<br />
Fire<br />
resistance<br />
(min)<br />
Integrity<br />
Fire<br />
resistance<br />
(min)<br />
Insulation<br />
Load<br />
bearing<br />
capacity<br />
under test<br />
conditions<br />
160 to 287 75 75 11.67kN<br />
per linear<br />
metre<br />
257.5 -<br />
329.5<br />
101 101 Not<br />
applicable<br />
Max<br />
unsupported<br />
span (m)<br />
Grading<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
2.6 FR60 PUR 558a/11<br />
3.0 FR90 PUR 558a/13<br />
Notes:<br />
SIP Firecheck system:<br />
1. LPCB Ref. 558a/11 - Hemsec SIP Firecheck panel system consists of rigid polyurethane foam core (125mm - 252mm thick)<br />
sandwiched between 15 mm orientated strand boards (OSB-3). The system was clad on the fire exposed face with a single layer of<br />
British Gypsum ‘Gyproc’ 12.5mm wall board (outer layer) and a single layer of British Gypsum ‘Gyproc Fireline’ 12.5mm board (inner<br />
layer), board layer joints staggered by 600mm and fixed to softwood timber batons at 600mm centres with 3.5mm x 50mm dry wall<br />
screws at 300mm centres. A total load of 35kN was applied for the duration of the test to a 3.0m wide test sample.<br />
52 20 Nov 2011
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
2. LPCB Ref 558a/13 - SIP Firecheck wall system is approved to LPS 1208 as a non load-bearing, non structural built up wall system of<br />
the following configuration; Rigid polyurethane foam core (150mm to 222mm thick) sandwiched between 15 mm orientated strand<br />
boards (Krono OSB-3), the panel size is 1.2m x 3.0m and installed with 3 metre joints vertical and consisting of 148mm deep x 70mm<br />
thick x 3000mm long timber spline joints inserted into 35mm pre-formed rebates in the core insulation, the joints are fixed with<br />
adhesive and nail fixings at 100mm centres. The system is clad on the fire exposed face with two layers of British Gypsum wall<br />
boards; A single layer of ‘Gyproc’ 12.5mm wall board (outer layer) and a single layer of ‘Gyproc Fireline’ 15mm board (inner layer),<br />
with the wall board joints between layers staggered by 600mm and fixed to softwood timber battens 50mm x 50mm spaced at 600mm<br />
centres with 3.5mm x 50mm dry wall screws at 300mm centres, the stud cavity is filled with Knauf Rocksilk Universal slab RW33<br />
insulation.<br />
ISOCAB France S.A.<br />
Avenue de la Gironde, Z.I. Petite Synthe, 59640 Dunkerque, France<br />
Tel: +33 328 29 26 30 • Fax: +33 328 60 11 93<br />
E-mail: info@isocabfrance.fr • Website: www.isocab.be<br />
Certificate No: 465b to LPS 1208: Issue 2<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Maximum<br />
unsupported<br />
span<br />
(m)<br />
Wall Panel<br />
orientation<br />
(HV) (note<br />
1)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity/Insulation<br />
Grade<br />
Core<br />
Material<br />
IND PIR (Wall panel 220 4.5 V 6/68 FR60 PIR 465b/01<br />
IND PIR (Wall panel) 110 4.5 V 37/37 FR30 PIR<br />
120 4.5 V 37/37 FR30 PIR<br />
140 4.5 V 37/37 FR30 PIR<br />
170 4.5 V 37/37 FR30 PIR<br />
200 4.5 V 68/68 FR60 PIR<br />
IND 20 PIR (Ceiling 200 4.4 - 42/42 FR30 PIR 465b/03<br />
panel)<br />
120 to 300 120 to 300 6.0 V 60/60 FR60 Mineral 844b/01<br />
Decaroc 50 F (Wall<br />
panel)<br />
Decaroc 50F (Wall<br />
panel)<br />
Decaroc 50 F (Ceiling<br />
panel)<br />
Fibre<br />
120 to 300 4.0 H 240/120 FR120 Mineral<br />
Fibre<br />
120 to 300 4.0 V 180/120 FR120 Mineral<br />
Fibre<br />
120 to 300 4.0 V 240/120 FR120 Mineral<br />
Fibre<br />
120 to 300 6.0 H 120/120 FR120 Mineral<br />
Fibre<br />
120 to 300 6.0 H 30/30 FR30 Mineral<br />
Fibre<br />
120 to 300 6.0 H 60/60 FR60 Mineral<br />
Fibre<br />
120 to 300 6.0 V 120/120 FR120 Mineral<br />
Fibre<br />
120 to 300 6.0 V 30/30 FR30 Mineral<br />
Fibre<br />
120 to 300 6.0 V 90/90 FR90 Mineral<br />
Fibre<br />
80 to 120 4.0 H 60/60 FR60 Mineral<br />
Fibre<br />
80 to 120 6.0 H 30/30 FR30 Mineral<br />
Fibre<br />
120 to 300 4.0 H 180/120 FR120 Mineral<br />
Fibre<br />
120 to 300 6.0 H 90/90 FR90 Mineral<br />
Fibre<br />
120 to 300 5.0 - 180/120 FR120 Mineral<br />
Fibre<br />
120 to 300 6.0 - 120/120 FR120 Mineral<br />
Fibre<br />
120 to 300 6.0 - 30/30 FR30 Mineral<br />
Fibre<br />
120 to 300 6.0 - 60/60 FR60 Mineral<br />
Fibre<br />
120 to 300 6.0 - 90/90 FR90 Mineral<br />
Fibre<br />
Cert.<br />
No.<br />
844b/02<br />
20 Nov 2011 53
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Notes:<br />
1) LPCB Refernce No. 844b/02, ceiling panel joints shall be stitched at 500mm centre's on the unexposed face with flat head steel<br />
screws.<br />
Isoclad Limited<br />
10 Alder Road, West Chirton North Industrial Estate, North Shields, Tyne & Wear NE29 8SD, United Kingdom<br />
Tel: +44 (0)191 258 5052 • Fax: +44 (0)191 259 5742<br />
E-mail: sales@isoclad.co.uk • Website: www.isoclad.co.uk<br />
Certificate No: 142a to LPS 1208: Issue 2<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Maximum<br />
Unsupported<br />
Panel<br />
Span<br />
(m)<br />
Wall Panel<br />
orientation<br />
(H/V)<br />
(note 1)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity /<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
Firestop 10 (wall panel) 75 3.0 V 30 / 30 FR30 Mineral<br />
fibre<br />
100 4.5 V 60 / 60 FR60 Mineral<br />
fibre<br />
100 5.5 V 30 / 30 FR30 Mineral<br />
fibre<br />
125 4.5 V 60 / 60 FR60 Mineral<br />
fibre<br />
125 5.5 V 30 / 30 FR30 Mineral<br />
fibre<br />
150 5.0 V 90 / 90 FR90 Mineral<br />
fibre<br />
150 5.5 V 30 / 30 FR30 MIneral<br />
fibre<br />
150 5.5 V 60 / 60 FR60 Mineral<br />
fibre<br />
175 5.0 V 90 / 90 FR90 Mineral<br />
fibre<br />
175 5.5 V 30 / 30 FR30 Mineral<br />
fibre<br />
175 5.5 V 60 / 60 FR60 Mineral<br />
fibre<br />
200 5.0 V 90 / 90 FR90 Mineral<br />
fibre<br />
200 5.5 V 30 / 30 FR30 Mineral<br />
fibre<br />
200 5.5 V 60 / 60 FR60 Mineral<br />
fibre<br />
Firestop10 (Wall Panel) 100 7.5 H or V 240 / 30 FR30 Mineral<br />
fibre<br />
100 7.5 H or V 240 / 60 FR60 Mineral<br />
fibre<br />
125 7.5 H or V 240 / 30 FR30 Mineral<br />
fibre<br />
125 7.5 H or V 240 / 60 FR60 Mineral<br />
fibre<br />
150 7.5 H or V 240 / 30 FR30 Mineral<br />
fibre<br />
150 7.5 H or V 240 / 60 FR60 Mineral<br />
fibre<br />
175 7.5 H or V 240 / 30 FR30 Mineral<br />
fibre<br />
175 7.5 H or V 240 / 60 FR60 Mineral<br />
fibre<br />
200 7.5 H or V 240 / 30 FR30 Mineral<br />
fibre<br />
200 7.5 H or V 240 / 60 FR60 Mineral<br />
fibre<br />
Firestop10 (Wall Panel) 100 4.35 H 60 / 60 FR60 Mineral<br />
fibre<br />
100 6.0 H 30 / 30 FR30 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
142a/01<br />
54 20 Nov 2011
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Maximum<br />
Unsupported<br />
Panel<br />
Span<br />
(m)<br />
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Wall Panel<br />
orientation<br />
(H/V)<br />
(note 1)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity /<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
125 4.35 H 60 / 60 FR60 Mineral<br />
fibre<br />
125 6.0 H 30 / 30 FR30 Mineral<br />
fibre<br />
150 4.35 H 60 / 60 FR60 Mineral<br />
fibre<br />
150 6.0 H 30 / 30 FR30 Mineral<br />
fibre<br />
175 4.35 H 60 / 60 FR60 Mineral<br />
fibre<br />
175 6.0 H 30 / 30 FR30 Mineral<br />
fibre<br />
200 4.35 H 60 / 60 FR60 Mineral<br />
fibre<br />
200 6.0 H 30 / 30 FR30 Mineral<br />
fibre<br />
Firestop 12 (wall panel) 75 3.0 V 30 / 30 FR30 Mineral 142a/02<br />
fibre<br />
75 3.0 V 60 / 60 FR60 Mineral<br />
fibre<br />
100 5.5 V 90 / 90 FR90 Mineral<br />
fibre<br />
100 6.0 V 60 / 60 FR60 Mineral<br />
fibre<br />
100 7.5 V 30 / 30 FR30 Mineral<br />
fibre<br />
125 5.5 V 90 / 90 FR90 Mineral<br />
fibre<br />
125 6.0 V 60 / 60 FR60 Mineral<br />
fibre<br />
125 7.5 V 30 / 30 FR30 Mineral<br />
fibre<br />
150 5.5 V 120 / 120 FR120 Mineral<br />
fibre<br />
150 5.5 V 90 / 90 FR90 Mineral<br />
fibre<br />
150 6.0 V 60 / 60 FR60 Mineral<br />
fibre<br />
150 7.5 V 30 / 30 FR30 Mineral<br />
fibre<br />
175 5.5 V 120 / 120 FR120 Mineral<br />
fibre<br />
175 5.5 V 90 / 90 FR90 Mineral<br />
fibre<br />
175 6.0 V 60 / 60 FR60 Mineral<br />
fibre<br />
175 7.5 V 30 / 30 FR30 Mineral<br />
fibre<br />
200 5.5 V 120 / 120 FR120 Mineral<br />
fibre<br />
200 5.5 V 90 / 90 FR90 Mineral<br />
fibre<br />
200 6.0 V 60 / 60 FR60 Mineral<br />
fibre<br />
200 7.5 V 30 / 30 FR30 Mineral<br />
fibre<br />
Firestop 12C (ceiling 100 to 200 3.0 - 60 / 60 FR60 Mineral 142a/03<br />
panel)<br />
fibre<br />
100 to 200 5.5 - 30 / 30 FR30 Mineral<br />
fibre<br />
Isoclad PIR (Wall panel) 100 3.0 V 46 / 41 FR30 PIR 142a/05<br />
Isoclad PIR (Ceiling<br />
150 3.4 - 80 / 50 FR30 PIR 142a/06<br />
panel)<br />
Isoclad PIR 40 (Wall<br />
Panel)<br />
150 4.0 V 60/30 FR30 PIR 142a/07<br />
Firestop 12 (Ceiling<br />
Panel)<br />
150 6.0 V 30/30 FR30 PIR<br />
100 4.4 - 63/63 FR60 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
142a/08<br />
20 Nov 2011 55
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Product Name<br />
Securiclad SR4 (Wall<br />
Panel)<br />
Securiclad SR4 (Ceiling<br />
Panel)<br />
Specification<br />
Thickness<br />
(mm)<br />
Maximum<br />
Unsupported<br />
Panel<br />
Span<br />
(m)<br />
Wall Panel<br />
orientation<br />
(H/V)<br />
(note 1)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity /<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
100 4.0 V 120/90 FR90 Mineral<br />
fibre<br />
100 4.0 V 180/90 FR90 Mineral<br />
fibre<br />
100 4.0 V 240/90 FR90 Mineral<br />
fibre<br />
100 4.0 V 90/90 FR90 Mineral<br />
fibre<br />
100 5.2 V 60/60 FR60 Mineral<br />
fibre<br />
100 7.5 V 30/30 FR30 Mineral<br />
fibre<br />
100 4.1 - 60/60 FR60 Mineral<br />
fibre<br />
100 7.5 - 30/30 FR30 Mineral<br />
fibre<br />
Cert.<br />
No.<br />
142a/09<br />
142a/10<br />
Notes:<br />
1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
2. LPCB Ref No 142a/01 where the Firestop 10 wall panels maximum unsupported span is listed as 7.5m the joints between the panels<br />
must be stitched on both internal and external faces with 4mm Ø stainless steel rivets at nominal 200mm centres and be sealed with<br />
Hilti CP 606 intumescent sealant on both faces.<br />
3. LPCB ref. No 142a/01 where the Firestop 10 wall panels are listed as installed horizontally (H) only, the joints between the panels are<br />
unstitched and sealed with a bead of Geocel Dow Corning Firestop 700 silicone sealant on both joint faces.<br />
4. LPCB Ref. No. 142a/03 The joints on the Firestop12 ceiling panels should be stitched with 3mm diameter rivets at 300mm centres on<br />
the internal and external face.<br />
5. LPCB ref. No 142a/05 Isoclad PIR Wall panels shall be stitched with 4.2mm diameter rivets at 150mm centres on the external face.<br />
6. LPCB ref. No 142a/06 Isoclad PIR ceiling panels shall be stitched with 4.2mm diameter rivets at 200mm centres on the internal and<br />
external face.<br />
7. LPCB ref. No 142a/07 Isoclad PIR 40 wall palenls, a bead of Hilti CP601 intumescent sealant call be applied to the female joint profile<br />
prior to installation then stitched with 4mm diameter rivets at 200mm centres on the internal and external face and sealed with a<br />
further bead of Hilti CP 601 intumescent sealant on both faces.<br />
8. LPCB ref No 142a/08, 142a/09 & 142a/10 the joints between the panels are unstitched. A bead of Envirograph 62 intumescent<br />
fieproof sealant shall be applied to the female joint profile prior to installation, and sealed with a further bead of Envirograph 62<br />
intumescent fireproof sealant on both faces.<br />
Kingspan Ltd<br />
Carrickmacross Road, Kingscourt, Co. Cavan, Ireland<br />
Tel: +353 42 969 8572 • Fax: +353 42 969 8576/77<br />
E-mail: info.irl@kingspanpanels.com • Website: www.kingspanpanels.com<br />
Certificate No: 186b to LPS 1208: Issue 2<br />
Product Name<br />
Kingspan Ecosafe KS1100CS (wall<br />
panel)<br />
Kingspan Ecosafe KS1100CS<br />
(ceiling panel)<br />
Kingspan Ecosafe KS1100CS (wall<br />
panel)<br />
Kingspan Ecosafe<br />
KS1100CS(ceiling panel)<br />
Kingspan Ecosafe KS1100CS (wall<br />
panel)<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Maximum<br />
Unsupported<br />
Length (m)<br />
Grade<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
100, 125,<br />
150,<br />
175 & 200<br />
195 31 4.00 FR30 PIR 279b/05<br />
100, 125, 150 58 32 3.40 FR30 PIR 279b/06<br />
175 & 200<br />
175 & 200 240 64 3.00 FR60 PIR 279b/07<br />
175 & 200 148 67 3.30 FR60 PIR 279b/08<br />
175 & 200 69 61 4.00 FR60 PIR 279b/09<br />
Note:<br />
1. LPCB Ref 279b/05, 279b/06, 279b/07, 279b/08 & 279b/09 Refer to model specification LPCB 11 Rev 1 for full details<br />
56 20 Nov 2011
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Kingspan Ltd.<br />
Greenfield Business Park No. 2, Greenfield, Holywell, Flintshire CH8 7HU, United Kingdom<br />
Tel: +44 (0)1352 716100 • Fax: +44 (0)1352 716161<br />
E-mail: info@kingspanpanels.com • Website: www.kingspanpanels.com<br />
Certificate No: 260b to LPS 1208: Issue 2<br />
Product Name<br />
Kingspan Ecosafe KS1100CS (wall<br />
panel)<br />
Kingspan Ecosafe KS1100CS<br />
(ceiling panel)<br />
Kingspan Ecosafe KS1100CS (wall<br />
panel)<br />
Kingspan Ecosafe KS1100CS<br />
(ceiling panel)<br />
Kingspan Ecosafe KS1100CS (wall<br />
panel)<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Maximum<br />
Unsupported<br />
Length (m)<br />
Grade<br />
Core<br />
Material<br />
Cert.<br />
No.<br />
100, 125,<br />
150,<br />
175 & 200<br />
195 31 4.00 FR30 PIR 279b/05<br />
100, 125, 58 32 3.40 FR30 PIR 279b/06<br />
150,<br />
175 & 200<br />
175 & 200 240 64 3.00 FR60 PIR 279b/07<br />
175 & 200 148 67 3.30 FR60 PIR 279b/08<br />
175 & 200 69 61 4.00 FR60 PIR 279b/09<br />
Note:<br />
1. LPCB Ref 279b/05, 279b/06, 279b/07, 279b/08 & 279b/09 Refer to model specification LPCB 11 Rev 1 for full details.<br />
Modular Panel Systems Limited<br />
Mohill, Co.Leitrim, Ireland<br />
Tel: +353 719631162 • Fax: +353 719651979<br />
E-mail: info@modular.ie • Website: www.modular.ie<br />
Certificate No: 750a to LPS 1208 Issue 2<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Max<br />
Unsupported<br />
Length (m)<br />
Grade<br />
Core<br />
Material<br />
Enviro Panel PIR (wall panel) 100 43 15 3.0 FR15 PIR 750a/01<br />
150 60 48 3.0 FR30 PIR<br />
200 60 48 3.0 FR30 PIR<br />
Enviro Panel Mineral wool (wall 100 121 44 7.5 FR30 Mineral wool 750a/02<br />
panel)<br />
Enviro Panel Mineral wool 150 121 68 3.0 FR60 Mineral wool 750a/03<br />
(ceiling panel)<br />
Enviro Panel PIR (wall panel) 100 30 15 3.0 FR15 PIR 750a/04<br />
150 60 30 3.0 FR30 PIR<br />
200 60 30 3.0 FR30 PIR<br />
Enviro Panel Mineral wool (wall 100 120 30 7.5 FR30 Mineral wool 750a/05<br />
panel)<br />
Enviro Panel Mineral wool 150 120 60 3.0 FR60 Mineral wool 750a/06<br />
(ceiling panel)<br />
Enviro Panel Mineral wool (wall<br />
panel)<br />
150 120 60 7.5 FR60 Mineral wool 750a/07<br />
Cert.<br />
No.<br />
Notes:<br />
1. LPCB Ref. 750a/01, 750a/02, 750a/04, 750a/05 & 750a/07 Wall panels shall be installed with the long joint in the vertical orientation.<br />
20 Nov 2011 57
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
2. LPCB Ref. 750a/01, 750a/03, 750a/04 & 750a/06 - A strip of Pyrostrip graphite self-adhesive tape, 10mm wide x 2mm thick, shall be<br />
applied between the overlap in the steel skins of adjacent panels, the joints of the Enviro panels shall then be stitched with 4.8mm dia<br />
x 10mm stainless steel rivets @ 300mm centres on both the exposed and internal face.<br />
3. LPCB Ref. 750a/02, 750a/05 & 750a/07 - A strip of Pyrostrip graphite self-adhesive tape, 10mm wide x 2mm thick, shall be applied<br />
between the overlap in the steel skins of adjacent panels, the joints of the Enviro panels shall then be stitched with 3.2mm dia x<br />
12mm stainless steel rivets @ 300mm centres on both the external and internal face.<br />
4. LPCB Ref. 750a/01, 750a/02 & 750a/03 PIR and Mineral wool panels are supplied with a castellated joint panel edge profile.<br />
5. LPCB Ref. 750a/04, 750a/05 & 750a/06 PIR and Mineral wool panels are supplied with a flat, butt joint panel edge profile.<br />
6. LPCB Ref. 750a/07 Mineral wool wall panels are supplied with a castellated joint or a flat, butt joint panel edge profile.<br />
Panel Projects Limited<br />
Portview Road, Avonmouth, Bristol BS11 9LQ, United Kingdom<br />
Tel: +44 (0)117 316 7000 • Fax: +44 (0)117 316 7001<br />
Certificate No: 881a to LPS 1208: Issue 2<br />
Wall Panels<br />
Product Name<br />
Firecold (wall<br />
panels)<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Maximum<br />
unsupported<br />
span (m)<br />
Grade<br />
Core<br />
Material<br />
Cert. No.<br />
100 30 30 6.2 FR30 Mineral wool 881a/01<br />
100 60 60 4.0 FR60 Mineral wool<br />
125 30 30 6.2 FR30 Mineral wool<br />
125 60 60 4.0 FR60 Mineral wool<br />
Note:<br />
1. LPCB Ref 881a/01 Wall panels to be installed with long joints in the vertical orientation only.<br />
Paroc Panel System Oy Ab<br />
FIN-21600, Parainen, Finland<br />
Tel: +358 46 876 8000 • Fax: +358 46 876 8702<br />
E-mail: panelinfo@paroc.com • Website: www.paroc.com<br />
Certificate No: 381a to LPS 1208: Issue 2<br />
AST F, AST S & AST T Wall Panels and AST E Ceiling Panels<br />
Product Name Specification<br />
Thickness<br />
(mm)<br />
Maximum<br />
Unsupported<br />
span (m)<br />
Wall panel<br />
orientation<br />
(H/V) (note<br />
1)<br />
Fire<br />
Resistance<br />
(mm)<br />
Integrity /<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
PAROC AST F (wall panel) 50 4.6 V 30/30 FR30 Mineral wool 381a/01<br />
80 4.0 V 90/90 FR90 Mineral wool<br />
80 4.9 V 60/60 FR60 Mineral wool<br />
80 7.5 V 30/30 FR30 Mineral wool<br />
100 4.0 V 120/120 FR120 Mineral wool<br />
100 4.4 V 90/90 FR90 Mineral wool<br />
100 6.6 V 60/60 FR60 Mineral wool<br />
100 7.5 V 30/30 FR30 Mineral wool<br />
120 4.0 V 180/180 FR180 Mineral wool<br />
120 4.8 V 120/120 FR120 Mineral wool<br />
120 6.4 V 90/90 FR90 Mineral wool<br />
120 7.5 V 30/30 FR30 Mineral wool<br />
120 7.5 V 60/60 FR60 Mineral wool<br />
100 - 240 4.0 H 120/120 FR120 Mineral wool<br />
120 - 240 4.0 H 180/180 FR180 Mineral wool<br />
150 - 240 4.0 H 240/240 FR240 Mineral wool<br />
Cert.<br />
No.<br />
58 20 Nov 2011
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Maximum<br />
Unsupported<br />
span (m)<br />
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Wall panel<br />
orientation<br />
(H/V) (note<br />
1)<br />
Fire<br />
Resistance<br />
(mm)<br />
Integrity /<br />
Insulation<br />
Grade<br />
Core<br />
Material<br />
150 - 240 4.0 V 240/240 FR240 Mineral wool<br />
150 - 240 4.7 V 180/180 FR180 Mineral wool<br />
150 - 240 7.1 V 120/120 FR120 Mineral wool<br />
150 - 240 7.5 V 30/30 FR30 Mineral wool<br />
150 - 240 7.5 V 60/60 FR60 Mineral wool<br />
150 - 240 7.5 V 90/90 FR90 Mineral wool<br />
50 -240 4.0 H 30/30 FR30 Mineral wool<br />
80 - 240 4.0 H 60/60 FR60 Mineral wool<br />
80 - 240 4.0 H 90/90 FR90 Mineral wool<br />
PAROC AST S (wall panel) 80 4.0 V 60/30 FR30 Mineral wool 381a/02<br />
80 5.1 V 30/30 FR30 Mineral wool<br />
100 4.0 V 60/60 FR60 Mineral wool<br />
100 6.7 V 30/30 FR30 Mineral wool<br />
120 4.0 V 120/120 FR120 Mineral wool<br />
120 4.6 V 90/90 FR90 Mineral wool<br />
120 6.9 V 60/60 FR60 Mineral wool<br />
120 7.5 V 30/30 FR30 Mineral wool<br />
100 - 240 4.0 H 60/60 FR60 Mineral wool<br />
120 - 240 4.0 H 120/120 FR120 Mineral wool<br />
120 - 240 4.0 H 90/90 FR90 Mineral wool<br />
150 - 240 4.0 H 180/180 FR180 Mineral wool<br />
150 - 240 4.0 H 240/240 FR240 Mineral wool<br />
150 - 240 4.0 V 240/240 FR240 Mineral wool<br />
150 - 240 4.1 V 180/180 FR180 Mineral wool<br />
150 - 240 6.1 V 120/120 FR120 Mineral wool<br />
150 - 240 7.5 V 30/30 FR30 Mineral wool<br />
150 - 240 7.5 V 60/60 FR60 Mineral wool<br />
150 - 240 7.5 V 90/90 FR90 Mineral wool<br />
80 - 240 4.0 H 30/30 FR30 Mineral wool<br />
80 - 240 4.0 H 60/30 FR30 Mineral wool<br />
PAROC AST E (ceiling<br />
panel)<br />
Cert.<br />
No.<br />
100 6.5 - 60/60 FR60 Mineral wool 381a/04<br />
100 8.2 - 30/30 FR30 Mineral wool<br />
PAROC AST T (wall panel) 80 4.0 V 30/30 FR30 Mineral wool 381a/05<br />
100 5.1 V 30/30 FR30 Mineral wool<br />
120 4.0 V 120/120 FR120 Mineral wool<br />
120 4.8 V 90/90 FR90 Mineral wool<br />
120 7.3 V 60/60 FR60 Mineral wool<br />
120 7.5 V 30/30 FR30 Mineral wool<br />
120 - 240 4.0 H 120/120 FR120 Mineral wool<br />
120 - 240 4.0 H 60/60 FR60 Mineral wool<br />
120 - 240 4.0 H 90/90 FR90 Mineral wool<br />
150 - 240 4.0 H 180/180 FR180 Mineral wool<br />
150 - 240 4.0 H 240/240 FR240 Mineral wool<br />
150 - 240 4.0 V 240/240 FR240 Mineral wool<br />
150 - 240 4.7 V 180/180 FR180 Mineral wool<br />
150 - 240 7.1 V 120/120 FR120 Mineral wool<br />
150 - 240 7.5 V 30/30 FR30 Mineral wool<br />
150 - 240 7.5 V 60/60 FR60 Mineral wool<br />
150 - 240 7.5 V 90/90 FR90 Mineral wool<br />
80 - 240 4.0 H 30/30 FR30 Mineral wool<br />
Notes:<br />
1. Wall orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
2. LPCB Ref 381a/01, 381a02 and 381a/05 when panels are laid with the long joint in the horizontal orientation the joints shall be<br />
stitched on the internal and external face at nominal 150mm centres.<br />
20 Nov 2011 59
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Promat UK Ltd<br />
The Sterling Centre, Eastern Road, Bracknell, Berkshire RG12 2TD, United Kingdom<br />
Tel: +44 (0)1344 381300 • Fax: +44 (0)1344 381301<br />
Website: www.promat.co.uk<br />
Certificate No: 545a to LPS 1208: Issue 2<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Maximum<br />
Unsupported<br />
Length (m)<br />
Grading<br />
Core<br />
Material<br />
Cert. No.<br />
Durawall 120 150 120 120 5.50 FR120 Mineral fibre 545a/01<br />
Durawall 90 125 90 90 5.50 FR90 Mineral fibre<br />
Durawall 60 100 60 60 4.50 FR60 Mineral fibre 545a/03<br />
Durawall 240 150 240 240 7.50 FR240 Mineral fibre 545a/11<br />
Notes:<br />
1. LPCB Ref. No’s 545a/01, 545a/03 and 545a/11 - Wall panels can be installed vertically or horizontally.<br />
2. LPCB Ref. No’s 545a/11 - wall panel joints to be stitched on both internal and external faces using 4.7mm Diameter x 20mm long<br />
self-tapping screws at 300mm centres.<br />
Ruukki Construction Oy<br />
PO Box 138, (Suolakivenkatu 1), 00811 Helsinki, Finland<br />
Tel: +358 20 592 7521 • Fax: +358 20 592 7708<br />
E-mail: simo.heikkila@ruukki.com • Website: www.ruukki.com<br />
Certificate No: 660a to LPS 1208: Issue 2<br />
Product<br />
Name<br />
Specification<br />
Thickness (mm)<br />
Max<br />
Unsupported<br />
Span (m)<br />
Wall panel<br />
orientation<br />
(H/V)<br />
(note 1)<br />
Fire<br />
resistance<br />
(min)<br />
Integrity /<br />
Insulation<br />
Grade<br />
Core<br />
material<br />
SPA-E 100 & 125 3.0 V or H 60/60 FR60 Mineral<br />
wool<br />
100, 125, 150, 175, 200, 6.0 V or H 30/30 FR30 Mineral<br />
230 & 260<br />
wool<br />
150, 175, 200, 230 & 260 3.0 V or H 90/90 FR90 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 5.0 V or H 60/60 FR60 Mineral<br />
wool<br />
SPA-I 100 & 125 3.0 V or H 60/60 FR60 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 5.0 V or H 60/60 FR60 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 6.0 V or H 30/30 FR30 Mineral<br />
wool<br />
SPA-F 100 3.0 V 180/120 FR120 Mineral<br />
wool<br />
100 3.8 H 120/120 FR120 Mineral<br />
wool<br />
100 4.5 V 120/120 FR120 Mineral<br />
wool<br />
100 5.1 H 90/90 FR90 Mineral<br />
wool<br />
100 6.0 V 90/90 FR90 Mineral<br />
wool<br />
100, 125, 150, 175, 200, 6.0 H or V 30/30 FR30 Mineral<br />
230 & 260<br />
wool<br />
100, 125, 150, 175, 200, 6.0 H or V 60/60 FR60 Mineral<br />
230 & 260<br />
wool<br />
Cert.<br />
No.<br />
660a/03<br />
660a/04<br />
660a/05<br />
60 20 Nov 2011
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Product<br />
Name<br />
Specification<br />
Thickness (mm)<br />
Max<br />
Unsupported<br />
Span (m)<br />
Wall panel<br />
orientation<br />
(H/V)<br />
(note 1)<br />
Fire<br />
resistance<br />
(min)<br />
Integrity /<br />
Insulation<br />
Grade<br />
Core<br />
material<br />
125, 150, 175, 200, 230 &<br />
260<br />
3.0 H or V 240/180 FR180 Mineral<br />
wool<br />
125, 150, 175, 200, 230 &<br />
260<br />
4.0 H or V 180/180 FR180 Mineral<br />
wool<br />
125, 150, 175, 200, 230 &<br />
260<br />
6.0 H or V 120/120 FR120 Mineral<br />
wool<br />
125, 150, 175, 200, 230 &<br />
260<br />
6.0 H or V 90/90 FR90 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 120/120 FR120 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 180/180 FR180 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 240/240 FR240 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 30/30 FR30 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 60/60 FR60 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 90/90 FR90 Mineral<br />
wool<br />
SPA-S 100 3.0 V 180/120 FR120 Mineral<br />
wool<br />
100 3.8 H 120/120 FR120 Mineral<br />
wool<br />
100 4.5 V 120/120 FR120 Mineral<br />
wool<br />
100 5.1 H 90/90 FR90 Mineral<br />
wool<br />
100 6.0 V 90/90 FR90 Mineral<br />
wool<br />
100, 125, 150, 175, 200, 6.0 H or V 30/30 FR30 Mineral<br />
230 & 260<br />
wool<br />
100, 125, 150, 175, 200, 6.0 H or V 60/60 FR60 Mineral<br />
230 & 260<br />
wool<br />
125, 150, 175, 200, 230 & 3.0 H or V 240/180 FR180 Mineral<br />
260<br />
wool<br />
125, 150, 175, 200, 230 & 4.0 H or V 180/180 FR180 Mineral<br />
260<br />
wool<br />
125, 150, 175, 200, 230 & 6.0 H or V 120/120 FR120 Mineral<br />
260<br />
wool<br />
125, 150, 175, 200, 230 & 6.0 H or V 90/90 FR90 Mineral<br />
260<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 120/120 FR120 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 180/180 FR180 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 240/240 FR240 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 30/30 FR30 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 60/60 FR60 Mineral<br />
wool<br />
150, 175, 200, 230 & 260 7.5 (note 2) H or V 90/90 FR90 Mineral<br />
wool<br />
Cert.<br />
No.<br />
660a/06<br />
Note:<br />
1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.<br />
2. LPCB Ref No. 660a/05 & 660a/06 where panels are approved with a span of 7.5m the joints must be stitched on both faces at<br />
300mm centers using 4.2mm-diameter flat head screws and then sealed using a Teknosafe 2002-00 intumescent paint.<br />
20 Nov 2011 61
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Specialist Panels UK Limited<br />
Bolam Business Park, Bassington Drive, Bassington Industrial Estate, Cramlington, Northumberland NE23<br />
8AD, United Kingdom<br />
Tel: +44(0) 1670 739116 • Fax: +44(0) 1670 732955<br />
E-mail: isowall@btinternet.com • Website: www.isowall.org.uk<br />
Certificate No: 957a to LPS1208: Issue 2<br />
Product Name<br />
Isowall (wall<br />
panel)<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
(min) Integrity<br />
Fire<br />
Resisitance<br />
(min)<br />
Insulation<br />
Max<br />
Unsupported<br />
Span (m)<br />
Grading<br />
Core<br />
Material<br />
100 98 98 4.0 FR90 Mineral<br />
wool<br />
125 120 120 3.0 FR120 Mineral<br />
wool<br />
150 265 208 3.0 FR120 Mineral<br />
wool<br />
150 265 208 4.0 FR90 Mineral<br />
wool<br />
Cert.<br />
No.<br />
957a/01<br />
Note:<br />
1. LPCB Ref No. 957a/01, Wall panels to be installed with long joints vertically only.<br />
Stancold plc<br />
Portview Road, Avonmouth, Bristol BS11 9LQ, United Kingdom<br />
Tel: +44 (0)117 316 7000 • Fax: +44 (0)117 316 7001<br />
E-mail: sales@stancold.co.uk • Website: www.stancold.co.uk<br />
Certificate No: 600a to LPS 1208: Issue 2<br />
Wall panels<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity<br />
(min)<br />
Fire Resistance<br />
Insulation<br />
(min)<br />
Maximum<br />
unsupported<br />
span (m)<br />
Grade<br />
Core<br />
material<br />
Cert. No.<br />
Firecold (wall panels) 100 30 30 6.2 FR30 Mineral wool 881a/01<br />
100 60 60 4.0 FR60 Mineral wool<br />
125 30 30 6.2 FR30 Mineral wool<br />
125 60 60 4.0 FR60 Mineral wool<br />
Note:<br />
1. LPCB Ref 881a/01 Wall panels to be installed with long joints in the vertical orientation only.<br />
62 20 Nov 2011
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Trimo d.d<br />
Prijatljeva 12, 8210 Trebnje, Slovenija<br />
Tel: 00386 73460200 • Fax: 0038 673460127<br />
E-mail: trimo@trimo.si • Website: www.trimo.eu<br />
UK Supplier<br />
Trimo UK Ltd, Unit 4 Willaston House, Crewe Road, Nantwich, Cheshire CW5 6NE, United Kingdom<br />
Tel: +44 (0) 1270 665303 • Fax: +44 (0) 1270 664294<br />
E-mail: trimo@trimo.org.uk • Website: www.trimo.org.uk<br />
Certificate No: 650a to LPS 1208: Issue 2<br />
Trimotherm Panels<br />
Product Name Specification<br />
Thickness<br />
(mm)<br />
Trimotherm FTV<br />
(wall panel)<br />
Specification<br />
Orientation<br />
of<br />
Long Edges<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
100 Horizontal 30 30 7.25 FR30 Mineral<br />
wool<br />
100 Horizontal 60 60 7.25 FR60 Mineral<br />
wool<br />
100 Horizontal 90 90 5.60 FR90 Mineral<br />
wool<br />
100 Vertical 30 30 7.25 FR30 Mineral<br />
wool<br />
100 Vertical 60 60 7.25 FR60 Mineral<br />
wool<br />
100 Vertical 90 90 5.60 FR90 Mineral<br />
wool<br />
120 Horizontal 30 30 8.00* FR30 Mineral<br />
wool<br />
120 Horizontal 60 60 8.00* FR60 Mineral<br />
wool<br />
120 Horizontal 90 90 8.00* FR90 Mineral<br />
wool<br />
120 Horizontal 120 120 8.00 FR120 Mineral<br />
wool<br />
120 Vertical 30 30 7.25 FR30 Mineral<br />
wool<br />
120 Vertical 60 60 7.25 FR60 Mineral<br />
wool<br />
120 Vertical 90 90 5.60 FR90 Mineral<br />
wool<br />
120 Vertical 120 120 4.00 FR120 Mineral<br />
wool<br />
150 Horizontal 30 30 8.00* FR30 Mineral<br />
wool<br />
150 Horizontal 60 60 8.00* FR60 Mineral<br />
wool<br />
150 Horizontal 90 90 8.00* FR90 Mineral<br />
wool<br />
150 Horizontal 120 120 8.00 FR120 Mineral<br />
wool<br />
150 Horizontal 180 180 4.00 FR180 Mineral<br />
wool<br />
150 Vertical 30 30 7.25 FR30 Mineral<br />
wool<br />
150 Vertical 60 60 7.25 FR60 Mineral<br />
wool<br />
150 Vertical 90 90 6.00 FR90 Mineral<br />
wool<br />
150 Vertical 120 120 5.5 FR120 Mineral<br />
wool<br />
150 Vertical 180 180 4.00 FR180 Mineral<br />
wool<br />
Cert.<br />
No.<br />
650a/01<br />
20 Nov 2011 63
PART 1: SECTION <strong>2.2</strong><br />
LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS<br />
Product Name<br />
Trimotherm FTV-<br />
H (wall panels)<br />
Trimotherm SNV<br />
(ceiling panels)<br />
Specification<br />
Thickness<br />
(mm)<br />
Specification<br />
Orientation<br />
of<br />
Long Edges<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Maximum<br />
Unsupported<br />
Span (m)<br />
Grade<br />
Core<br />
Material<br />
200 Horizontal 30 30 8.00* FR30 Mineral<br />
wool<br />
200 Horizontal 60 60 8.00* FR60 Mineral<br />
wool<br />
200 Horizontal 90 90 8.00* FR90 Mineral<br />
wool<br />
200 Horizontal 120 120 8.00 FR120 Mineral<br />
wool<br />
200 Horizontal 180 180 4.00 FR180 Mineral<br />
wool<br />
200 Vertical 30 30 7.25 FR30 Mineral<br />
wool<br />
200 Vertical 60 60 7.25 FR60 Mineral<br />
wool<br />
200 Vertical 90 90 600 FR90 Mineral<br />
wool<br />
200 Vertical 120 120 5.00 FR120 Mineral<br />
wool<br />
200 Vertical 180 180 4.00 FR180 Mineral<br />
wool<br />
100 Vertical 30 30 6.00 FR30 Mineral<br />
wool<br />
100 Vertical 30 30 6.00 FR30 Mineral<br />
wool<br />
100 Vertical 60 60 4.85 FR60 Mineral<br />
wool<br />
100 Vertical 90 90 4.00 FR90 Mineral<br />
wool<br />
120 Vertical 30 30 6.00 FR30 Mineral<br />
wool<br />
120 Vertical 60 60 4.85 FR60 Mineral<br />
wool<br />
120 Vertical 90 90 4.00 FR90 Mineral<br />
wool<br />
150 Vertical 30 30 6.00 FR30 Mineral<br />
wool<br />
150 Vertical 60 60 4.85 FR60 Mineral<br />
wool<br />
150 Vertical 90 90 4.00 FR90 Mineral<br />
wool<br />
100 - 98 95 2.00 FR90 Mineral<br />
wool<br />
120 - 98 95 2.00 FR90 Mineral<br />
wool<br />
150 - 98 95 2.00 FR90 Mineral<br />
wool<br />
200 - 98 95 2.00 FR90 Mineral<br />
wool<br />
Cert.<br />
No.<br />
650a/02<br />
650a/03<br />
Note:<br />
1. LPCB Ref. No. 650a/01 - unsupported spans marked *, span can be extended to 10.4m in respect of the length of the panel in<br />
horizontal laid orientation only.<br />
64 20 Nov 2011
PART 1: SECTION 2.3<br />
LPS 1581 EXTERNAL CLADDING SYSTEMS ON A MASONRY SUBSTRATE<br />
LPS 1581 Requirements and tests for LPCB approval of non-load bearing External Thermal Insulated<br />
Cladding Systems with rendered finishes (ETICS) or Rain Screen Cladding systems (RSC) applied to the<br />
masonry face of a building.<br />
20 Nov 2011 65
PART 1: SECTION 2.3.1<br />
LPS 1581 EXTERNAL THERMAL INSULATED CLADDING (ETICS) ON MASONRY SUBSTRATES<br />
LPS 1581 Requirements and tests for LPCB approval of non-load bearing External Thermal Insulated<br />
Cladding Systems with rendered finishes (ETICS) or Rain Screen Cladding systems (RSC) applied to the<br />
masonry face of a building<br />
The test method used is BS 8414-1:2002 Test method for non-load bearing external cladding systems applied<br />
to the face of the building and is representative of an external fire source or fully developed (post-flashover)<br />
fire in a room venting through an opening such as a window aperture that exposes the external surfaces of the<br />
cladding system to the effects of the impinging flames. The test method determines external and potential<br />
internal (within the ETICS system) fire spread and, where a void exists, the extent of fire spread through the<br />
void.<br />
External Thermal Insulated Composite Systems (ETICS) are systems which are applied to a masonry or<br />
concrete leaf, typically comprising of a number of layers including an insulation layer, a reinforcing mesh and<br />
external render or pre-formed slips or similar finish.<br />
Dryvit UK Limited<br />
Unit 4, Wren Park, Hitchin Road, Shefford, Bedfordshire SG17 5JD, United Kingdom<br />
Tel: +44 (0)1462 819555 • Fax: +44 (0)1462 819556<br />
E-mail: ukenquiries@dryvit.com • Website: www.dryvit.co.uk<br />
Certificate No: 784a to LPS 1581: Issue 1<br />
Product Name<br />
Roxsulation S<br />
Outsulation &<br />
Outsulation Plus<br />
Fedderlite Panel<br />
system<br />
External<br />
layer detail<br />
See Note<br />
1 & 3<br />
See Note<br />
1 & 5<br />
See Note<br />
1 & 8<br />
Insulation<br />
material type &<br />
thickness<br />
Mineral wool,<br />
thickness range<br />
40-200mm<br />
See Note 4<br />
EPS, thickness<br />
50-250mm<br />
See Note 6<br />
EPS, thickness<br />
range 50-120mm<br />
Cavity type and maximum<br />
depth<br />
Firebreak<br />
detail<br />
EN 13501-1<br />
Classification<br />
No cavity Continuous No Performance<br />
Determined<br />
No cavity See Note 7 B-s2-d0<br />
See Note 1<br />
Encapsulated cavity<br />
between substrate and rear<br />
of Fedderlite panel<br />
See Note 9<br />
B-s2-d0<br />
See Note 1<br />
Cert.<br />
No.<br />
784a/01<br />
784a/02<br />
985a/01<br />
Notes:<br />
General.<br />
1. LPCB Ref. No. 784a/01, 784a/02 & 985a/01 - Approved systems consist of Dryvit Genesis base coat, Dryvit Standard Plus reinforcing<br />
mesh, with or without Dryvit primer and a Dryvit Quarzputz PMRB, Sandpebble PMRB or Sandpebble Fine PMRB top coat, natural or<br />
tinted with a Qpcs value of up to 2.95MJ/kg.<br />
LPCB Ref. No. 784a/02 & 985a/01 The stated EN 13501-1 classification is applicable to systems with a PMRB top coat, natural or<br />
tinted with a Qpcs value up to 2.63MJ/kg only.<br />
2. Subject to the stated conditions the Roxsulation S system (LPCB Ref. No 784a/01) shall be installed in accordance with the<br />
application detail contained within Dryvit document DUK628 (June 2008). Outsulation & Outsulation Plus systems (LPCB Ref. No.<br />
784a/02) shall be installed in accordance with the application detail contained within Dryvit documents DUK204 (21/01/08) and<br />
DUK218 (V1 21-2-07) respectively. And the Fedderlite panel system (LPCB Ref. No. 985a/01) shall be installed in accordance with<br />
the application detail contained within Dryvit document DUK217 Issue 003 31/01/11 - Fedderlite manufacturing instructions and<br />
DUK920 - Fedderlite installation instructions.<br />
Roxsulation S - LPCB Ref. No 784a/01<br />
3. The system is approved with or without horizontal expansion joints in the render and insulation layer.<br />
4. The insulation boards are adhesively and mechanically fixed to the substrate with Dryvit Genesis adhesive, ribbon and dab method<br />
with a minimum of 8 dabs per full size board, and a minimum of 3 mechanical fixings per board.<br />
Outsulation & Outsulation Plus - LPCB Ref. No 784a/02<br />
5. The system is approved with or without horizontal expansion joints in the render and insulation layer.<br />
66 20 Nov 2011
PART 1: SECTION 2.3.1<br />
LPS 1581 EXTERNAL THERMAL INSULATED CLADDING (ETICS) ON MASONRY SUBSTRATES<br />
6. Dryvit EPS insulation boards adhered to the substrate with Dryvit Genesis adhesive.<br />
7. Minimum 100mm high continuous horizontal lamella fire breaks shall be affixed direct to the substrate with continuous band of Dryvit<br />
Genesis adhesive. The fire breaks shall be positioned at a maximum of 870mm above openings and a maximum of 3100mm centres<br />
between consecutive breaks.<br />
Fedderlite - LPCB Ref. No 985a/01<br />
8. Joints between Fedderlite panels are nominally 20mm wide and are filled with a 25mm closed cell polyethylene backer rod to produce<br />
a 10mm deep cavity to which an approved silicone sealant is applied.<br />
9. Fire breaks shall be incorporated as follows;<br />
a. Horizontal and vertical fire breaks are required around the perimeter of openings (top and sides only), these perimeter fire breaks<br />
consist of 100mm wide barrier adhered directly to the substrate with a continuous layer of Dryvit Genesis adhesive and shall be of<br />
sufficient thickness to create a tight fit between the panel face and substrate.<br />
b. Continuous horizontal cavity fire breaks consist of a 100mm high barrier bonded with Genesis adhesive to the substrate; these<br />
shall be positioned at a maximum of 850mm above openings and a maximum of 3320mm between subsequent horizontal breaks<br />
and shall be of sufficient thickness to create a tight fit between the panel face and substrate.<br />
c. Vertical fire breaks (external corners) consist of 100mm wide barriers located directly behind panels on external corner/edges,<br />
these vertical breaks are bonded with Genesis adhesive to the substrate and shall be of sufficient thickness to create a tight fit<br />
between the panel face and substrate.<br />
d. Vertical fire breaks (joints) consist of a 100mm wide barrier to span the joint, overlapping each panel edge by approximately<br />
40mm, and bonded directly to the substrate with a continuous layer of Dryvit Genesis adhesive.<br />
Rockwool Limited<br />
Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom<br />
Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302<br />
E-mail: info@rockwool.co.uk • Website: www.rockwool.co.uk<br />
Certificate No: 022h to LPS 1581: Issue 1<br />
Product Name<br />
RockShield<br />
External<br />
layer<br />
detail<br />
See<br />
Note 1<br />
Insulation<br />
material<br />
type &<br />
thickness<br />
(mm)<br />
Rockwool<br />
thickness<br />
range 30-<br />
150mm<br />
See note 2<br />
Cavity type &<br />
maximum depth<br />
(mm)<br />
Firebrakd<br />
detail<br />
EN 13501-1<br />
Classification<br />
N/A Continuous No<br />
Performance<br />
Determined<br />
Cert. No.<br />
022h/01<br />
Notes:<br />
1. LPCB Ref. No. 022h/01 - RockShield base coat with universal reinforcing mesh with a white RockShield Silcoplast topcoat.<br />
2.. LPCB Ref. No. 022h/01 - RockShield insulation boards of nominally 1200mm x 600mm fixed to the masonry substrate using 4-5mm<br />
layer of RockShield adhesive mortar, and then mechanically fixed using TI anchors fixed at a rate of 5.56 per m².<br />
Sto Ltd<br />
2 Gordon Avenue, Hillington Park, Glasgow G52 4TG, United Kingdom<br />
Tel: +44 (0)141 892 8000 • Fax: +44 (0)141 404 9001<br />
E-mail: info.uk@stoeu.com • Website: www.sto.co.uk<br />
Certificate No: 749a to LPS 1581: Issue 2.0<br />
20 Nov 2011 67
PART 1: SECTION 2.3.1<br />
LPS 1581 EXTERNAL THERMAL INSULATED CLADDING (ETICS) ON MASONRY SUBSTRATES<br />
Product Name<br />
External<br />
layer<br />
detail<br />
Insulation<br />
material type &<br />
thickness (mm)<br />
StoTherm Vario M See Note 1a EPS, thickness<br />
range 60-<br />
150mm see<br />
Note 2<br />
See Note 1b<br />
EPS, thickness<br />
150mm See<br />
Note 2<br />
Cavity type &<br />
maximum depth<br />
(mm)<br />
A cavity of<br />
maximum of 10mm<br />
is formed between<br />
the EPS insulation<br />
and masonry<br />
substrate<br />
A cavity of<br />
Maximum of 10mm<br />
is formed between<br />
the EPS insulation<br />
and masonry<br />
substrate<br />
Firebreak<br />
detail<br />
See Note 3<br />
See Note 3<br />
EN13501-1<br />
Classification<br />
No<br />
Performance<br />
Determined<br />
No<br />
Performance<br />
Determined<br />
Cert. No.<br />
749a/01<br />
749a/02<br />
Notes:<br />
1.<br />
a. LPCB Ref. No. 749a/01 - StoTherm EPS M Render, StoArmat Novo base coat with Sto Glass fibre Mesh F reinforcing mesh and<br />
Sto Stolit K2,0 top coat, natural or tinted with a PCS value of up to 2.36MJ/kg. A Secondary layer of Sto Glass fibre Mesh F<br />
reinforcing mesh is also required in any area that may be subject to flame impingement.<br />
b. LPCB Ref. No. 749a/02 - StoTherm EPS M Render, StoArmat Novo base coat with Sto Glass fibre Mesh F reinforcing mesh and<br />
Sto Stolit K2,0 top coat, natural or tinted with a PCS value of up to 2.36MJ/kg.<br />
2. LPCB Ref. No. 749a/01 & 749a/02 - StoTherm Vario M insulation boards of nominally 500mm x 500mm fixed to a mechanical rail<br />
system with PVC interlocking vertical T splines, the mechanical rails shall be fixed to the masonry substrate with Sto-Fixing Screw<br />
dowel UEZ8 085 CS fixings (or other suitable fixing ependant on masonry substrate type) at a maximum spacing of 300mm. The<br />
drainage cavity between the insulation and the masonry substrate is produced via the Sto aluminium starter track and horizontal PVC<br />
rails using Sto plastic shims.<br />
3. LPCB Ref. No. 749a/01 & 749a/02 - Sto Mineral Lamella Firebreak details as follows;<br />
a. 200mm high Sto Mineral Lamella fire break along top edge and sides of openings adhered direct to the masonry substrate with<br />
additional mechanical fixings(Sto Firebreak Dowel SS with integral head) at 300mm centres through the reinforcing mesh and<br />
firebreak into the masonry substrate.<br />
b. 200mm high continuous horizontal Sto Mineral Fibre Lamella fire break installed using a continuous layer of StoLevell-Uni<br />
adhesive, the fire break is additionally affixed with mechanical fixings (Sto SS fixing screw and washer) at 300mm centres through<br />
the reinforcing mesh and firebreak into the masonry substrate. Maximum spacing of continuous fire break; 1500mm above<br />
openings and maximum of 3000mm centres between consecutive breaks.<br />
Weber, Saint-Gobain Weber Limited<br />
Dickens House, Enterprise Way, Maulden Road, Flitwick, Bedfordshire MK45 5BY, United Kingdom<br />
Tel: +44 (0)8703 330070 • Fax: +44 (0)1525 718988<br />
E-mail: mail@netweber.co.uk • Website: www.netweber.co.uk<br />
Certificate No: 796a to LPS 1581: Issue 1<br />
Product Name<br />
Specification<br />
Thickness<br />
(mm)<br />
Insulation Material<br />
Fixing Method<br />
Maximum Vertical<br />
Firebreak Distance<br />
(m)<br />
Grade Insulation Material Cert. No.<br />
weber.therm XM (MFS) 50 - 170 Mechanical Continuous ETIC-1 Mineral fibre 796a/01<br />
Notes:<br />
1. Ref LPCB Ref. No. 796a/01, Insulation material mechanical fixings minimum of 4 ejotherm plastic head fixings per board and<br />
stainless steel fire fixings at 1/m 2 .<br />
2. Ref LPCB Ref. No. 796a/01, system available without top coat or with 6-8mm thick weber.rend PTC or PTS top coat, finish either<br />
scrape texture, dry-dash or primer and synthetic coating.<br />
68 20 Nov 2011
PART 1: SECTION 2.3.2<br />
LPS 1581 RAIN SCREEN CLADDING SYSTEMS (RSC) ON MASONRY SUBSTRATES<br />
LPS 1581 Requirements and tests for LPCB approval of non-load bearing External Thermal Insulated<br />
Cladding Systems with rendered finishes (ETICS) or Rain Screen Cladding systems (RSC) applied to the<br />
masonry face of a building<br />
The test method used is BS 8414-1:2002 Test method for non-load bearing external cladding systems applied<br />
to the face of the building and is representative of an external fire source or fully developed (post-flashover)<br />
fire in a room venting through an opening such as a window aperture that exposes the external surfaces of the<br />
cladding system to the effects of the impinging flames. The test method determines external and potential<br />
internal fire spread and, where a void exists, the extent of fire spread through the void.<br />
Rain Screen Cladding (RSC) systems are often used for the refurbishment of existing buildings where the<br />
insulation component is typically fixed to the original masonry face of the building. The external face of the<br />
cladding system is fixed to a supporting rail, so that the external face is spaced away from the insulation layer<br />
to form a cavity which may be drained.<br />
Sotech Limited<br />
2 Traynor Way, Whitehouse Business Park, Peterlee, County Durham SR8 2RU, United Kingdom<br />
Tel: +44 (0)191 587 2287 • Fax: +44 (0)191 518 0703<br />
E-mail: mail@sotech-optima.co.uk • Website: www.sotech-optima.co.uk<br />
Certificate No: 770a to LPS 1581: Issue 2<br />
Product Name<br />
Sotech Optima<br />
Rainscreen<br />
System<br />
External<br />
layer detail<br />
Aluminium<br />
cassette See<br />
Note 1<br />
Insulation<br />
material<br />
type &<br />
thickness<br />
(mm)<br />
75mm mineral<br />
fibre. See Note<br />
2<br />
Cavity<br />
type and<br />
maximum<br />
depth<br />
(mm)<br />
Cavity of maximum 200mm<br />
depth between rear of<br />
cassette system and face of<br />
insulation<br />
Firebreak<br />
detail<br />
See Note<br />
3<br />
EN 13501-1<br />
Classification<br />
No Performance<br />
Determined<br />
Cert.<br />
No.<br />
770a/04<br />
Notes:<br />
1. LPCB Ref. No. 770a/04 - Sotech Optima Rainscreen cassette system consists of aluminium cassette panels precoated with pvdf to<br />
the following scope;<br />
Cassette Panel Material Cassette Height (mm) Max. Single Span* (mm)<br />
Aluminium 1.5mm 500 1500<br />
600 1500<br />
750 1500<br />
900 1350<br />
1100 1200<br />
Aluminium 2.0mm 500 1800<br />
600 1800<br />
750 1800<br />
900 1500<br />
1100 1200<br />
Aluminium 3.0mm 500 1800<br />
600 1800<br />
750 1800<br />
900 1600<br />
* Multiple spans are allowable provided that the intermediate supports are installed at centres not exceeding the maximum single<br />
span distances.<br />
2. LPCB Ref. No. 770a/04 - Insulation consists of Rainscreen Duo-slab Mineral fibre, 75mm thick and affixed through the sheathing<br />
board to the SFS with a minimum of one central stainless steel Ejot TID anchor (or similar specification) per slab plus one Ejot DH<br />
plastic anchor (or similar specification) at each slab end butt joint.<br />
20 Nov 2011 69
PART 1: SECTION 2.3.2<br />
LPS 1581 RAIN SCREEN CLADDING SYSTEMS (RSC) ON MASONRY SUBSTRATES<br />
3. LPCB Ref. No. 770a/04 - fire breaks consist of a lamella/intumescent strip system located at a maximum height intervals of 2.5m.<br />
70 20 Nov 2011
PART 1: SECTION 2.4<br />
LPS 1582 EXTERNAL CLADDING SYSTEMS SUPPORTED BY A STRUCTURAL STEELWORK FRAME<br />
LPS 1582 Requirements and tests for LPCB approval of non-load bearing external cladding systems fixed to<br />
and supported by a structural steel frame.<br />
20 Nov 2011 71
PART 1: SECTION 2.4.1<br />
LPS 1582 EXTERNAL THERMAL INSULATED CLADDING (ETICS) SUPPORTED BY A STRUCTURAL<br />
STEEL FRAME<br />
LPS 1582 Requirements and tests for LPCB approval of non-load bearing external cladding systems fixed to<br />
and supported by a structural steel frame.<br />
This standard is applicable to non-load bearing external cladding systems, such as curtain walling, glazed<br />
elements, infill panels and insulated composite panel systems fixed to and supported by a structural steel<br />
frame.<br />
The test method used is BS 8414-2: 2005 Test method for non-load bearing external cladding systems fixed<br />
to and supported by a structural steel frame, and is intended to represent the action of a fully developed (post<br />
flashover) fire in a room venting through an opening such as a window aperture, or an external fire source that<br />
exposes the external surfaces of the cladding system to the effects of the impinging flames. The test method<br />
determines external and potential internal and fire spread and, where a void exists, the extent of fire spread<br />
through the void.<br />
Dryvit UK Limited<br />
Unit 4, Wren Park, Hitchin Road, Shefford, Bedfordshire SG17 5JD, United Kingdom<br />
Tel: +44 (0)1462 819555 • Fax: +44 (0)1462 819556<br />
E-mail: ukenquiries@dryvit.com • Website: www.dryvit.co.uk<br />
Certificate No: 784b to LPS 1582 Issue 1<br />
Product<br />
Name<br />
Outsulation &<br />
Outsulation<br />
Plus<br />
Outsulation<br />
Rail<br />
Fedderlite<br />
Panel System<br />
External<br />
layer<br />
detail<br />
See Note<br />
1& 4<br />
See Note<br />
1& 7<br />
See Note<br />
1 & 10<br />
Insulation<br />
material<br />
type &<br />
thickness<br />
EPS Thickness<br />
range 50-<br />
250mm See<br />
Note 5<br />
EPS Thickness<br />
range 50-<br />
250mm See<br />
Note 8<br />
EPS Thickness<br />
range 50-<br />
120mm<br />
Frame<br />
type<br />
&<br />
sheathing<br />
board<br />
See Note<br />
2<br />
See Note<br />
2<br />
See Note<br />
2<br />
Cavity<br />
type and<br />
maximum<br />
depth<br />
No cavity<br />
Drainage cavity of<br />
maximum 15mm depth<br />
between sheathing board<br />
and fire break<br />
Encapsulated Cavity<br />
between sheathing board<br />
and rear of Fedderlite<br />
panel<br />
Firebreak<br />
detail<br />
See Note<br />
6<br />
See Note<br />
9<br />
See Note<br />
11<br />
EN 13501-1<br />
Classification<br />
B-s2-d0<br />
See Note 1<br />
B-s2-d0<br />
See Note 1<br />
B-s2-d0<br />
See Note 1<br />
Cert.<br />
No.<br />
784b/01<br />
784b/02<br />
985b/01<br />
Notes:<br />
General.<br />
1. LPCB Ref. No. 784b/01, 784b/02 & 985b/01 - Approved systems consist of Dryvit Genesis base coat, Dryvit Standard Plus reinforcing<br />
mesh, with or without Dryvit primer and a Dryvit Quarzputz PMRB, Sandpebble PMRB or Sandpebble Fine PMRB top coat, natural or<br />
tinted with a Qpcs value of up to 2.95MJ/kg.<br />
The stated EN 13501-1 classification is applicable to systems with a PMRB top coat, natural or tinted with a Qpcs value up to<br />
2.63MJ/kg only.<br />
2. LPCB Ref. No. 784b/01, 784b/02 & 985b/01 - Any galvanised steel frame system, installed between floor slabs, confirmed by<br />
structural assessment to maintain the structural stability of the wall system in ambient conditions, and is suitable for the fire<br />
performance of the wall when exposed to fire within the building. The studs must have a minimum leg length of 45mm and be spaced<br />
at a maximum of 600mm centres (the stud size as tested was 100mm x 45mm x 1.2mm). The frame shall be clad with any sheathing<br />
board system suitable for the application on the external (cladding) face of the following generic types:- cement <strong>part</strong>icle board (min.<br />
12mm thick), cement-based calcium silicate board (min. 9mm thick), calcium silicate board (min. 9mm thick) or magnesium oxide<br />
board (min. 9mm thick). The system is approved with or without mineral wool insulation within the steel frame stud cavity. The internal<br />
face frame shall be clad with any type of gypsum wallboard that ensures that the required reaction-to-fire and fire resistance<br />
performance is provided when the wall is exposed to fire within the building.<br />
3. Subject to the stated conditions the Outsulation & Outsulation Plus systems (LPCB Ref. No. 784b/01) shall be installed in accordance<br />
with the application detail contained within Dryvit documents DUK204 (21/01/08) and DUK218 (V1 21-2-07) respectively. The<br />
Outsulation Rail system (LPCB Ref. No. 784b/02) shall be installed in accordance with the application detail contained within Dryvit<br />
document DUK664 (21-08-07) and the Fedderlite panel system (LPCB Ref. No. 985b/01) shall be installed in accordance with the<br />
72 20 Nov 2011
PART 1: SECTION 2.4.1<br />
LPS 1582 EXTERNAL THERMAL INSULATED CLADDING (ETICS) SUPPORTED BY A STRUCTURAL<br />
STEEL FRAME<br />
application detail contained within Dryvit document DUK217 Issue 003 31/01/11 - Fedderlite manufacturing instructions and DUK920<br />
- Fedderlite installation instructions. See BRE Assessment CC270532 for scope of components and variations.<br />
Outsulation & Outsulation Plus - LPCB Ref. No 784b/01<br />
4. The system is approved with or without horizontal expansion joints in the render and insulation layer.<br />
5. Dryvit EPS insulation boards adhered to the sheathing board with Dryvit Genesis adhesive.<br />
6. Minimum 100mm high continuous horizontal lamella fire breaks shall be affixed direct to the sheathing board with continuous band of<br />
Dryvit Genesis adhesive. The fire breaks shall be positioned at a maximum of 870mm above openings and a maximum of 3100mm<br />
centres between consecutive breaks.<br />
Outsulation Rail - LPCB Ref. No 784b/02<br />
7. The system is approved with or without horizontal expansion joints in the render and insulation layer.<br />
8. Dryvit EPS insulation boards fixed to a mechanical PVC ‘T’ spline railing system. The rails are fixed to the sheathing board using<br />
packing shims of up to 15mm thick at 300mm centres with suitable fixings to form the drainage cavity.<br />
9. The cavity fire break system and continuous horizontal lamella fire breaks shall be positioned a maximum of 800mm above openings,<br />
subsequent fire breaks shall be positioned at each floor slab at a maximum spacing of 3100mm centres.<br />
Fedderlite - LPCB Ref. No 985b/01<br />
10. Joints between Fedderlite panels are nominally 20mm wide and are filled with a 25mm closed cell polyethylene backer rod to produce<br />
a 10mm deep cavity to which an approved silicone sealant is applied.<br />
11. Fire breaks shall be incorporated as follows;<br />
a. Horizontal and vertical fire breaks are required around the perimeter of openings (top and sides only), these perimeter fire breaks<br />
consist of 100mm wide barrier adhered directly to the sheathing board with a continuous layer of Dryvit Genesis adhesive and<br />
shall be of sufficient thickness to create a tight fit between the panel face and substrate.<br />
b. Continuous horizontal cavity fire breaks consist of a 100mm high barrier bonded with Genesis adhesive to the sheathing board;<br />
these shall be positioned at a maximum of 850mm above openings and a maximum of 3320mm between subsequent horizontal<br />
breaks and shall be of sufficient thickness to create a tight fit between the panel face and substrate.<br />
c. Vertical fire breaks (external corners) consist of 100mm wide barriers located directly behind panels on external corner/edges,<br />
these vertical breaks are bonded with Genesis adhesive to the sheathing board and shall be of sufficient thickness to create a<br />
tight fit between the panel face and substrate.<br />
d. Vertical fire breaks (joints) consist of a 100mm wide barrier to span the joint, overlapping each panel edge by approximately<br />
40mm, and bonded directly to the sheathing board with a continuous layer of Dryvit Genesis adhesive.<br />
Sto Ltd<br />
2 Gordon Avenue, Hillington Park, Glasgow G52 4TG, United Kingdom<br />
Tel: +44 (0)141 892 8000 • Fax: +44 (0)141 404 9001<br />
E-mail: info.uk@stoeu.com • Website: www.sto.co.uk<br />
Certificate No: 749b to LPS 1582: Issue 1.0<br />
20 Nov 2011 73
PART 1: SECTION 2.4.1<br />
LPS 1582 EXTERNAL THERMAL INSULATED CLADDING (ETICS) SUPPORTED BY A STRUCTURAL<br />
STEEL FRAME<br />
Product Name<br />
StoTherm Vario M<br />
StoTherm Mineral M<br />
External<br />
layer<br />
detail<br />
See<br />
Note 1<br />
See<br />
Note 5<br />
Insulation<br />
material<br />
type &<br />
thickness<br />
(mm)<br />
EPS,<br />
thickness<br />
range 60-<br />
150mm<br />
See Note<br />
2<br />
Mineral<br />
fibre,<br />
thickness<br />
range 60-<br />
150mm<br />
See Note<br />
6<br />
Frame<br />
type and<br />
sheathing<br />
board<br />
See Note<br />
3<br />
See Note<br />
7<br />
Cavity<br />
type &<br />
maximum<br />
depth<br />
(mm)<br />
Drainage<br />
cavity of<br />
maximum<br />
20mm<br />
depth<br />
between<br />
sheathing<br />
board and<br />
insulation<br />
Drainage<br />
cavity of<br />
maximum<br />
20mm<br />
depth<br />
between<br />
sheathing<br />
board and<br />
insulation<br />
Firebreak<br />
detail<br />
See Note<br />
4<br />
See Note<br />
8<br />
EN13501-1<br />
Classification<br />
No<br />
Performance<br />
Determined<br />
No<br />
Performance<br />
Determined<br />
Cert. No.<br />
749b/01<br />
749b/02<br />
Notes:<br />
1. LPCB Ref. No. 749b/01 - StoTherm EPS M Render, StoArmat Novo base coat with Sto Glass fibre Mesh F reinforcing mesh and Sto<br />
Stolit K2,0 top coat, natural or tinted with a PCS value of up to 2.36MJ/kg. A Secondary layer of Sto Glass fibre Mesh F reinforcing<br />
mesh is also required in any area that may be subject to flame impingement.<br />
2 LPCB Ref. No. 749b/01 - StoTherm Vario M insulation boards of nominally 500mm x 500mm fixed to a mechanical rail system with<br />
PVC interlocking vertical T splines, the mechanical rails shall be fixed to the sheathing board with Sto-Screw fixings, CS self-tapping<br />
5.5 x 50mm screw fixings at a maximum spacing of 300mm. The drainage cavity between the insulation and the sheathing board is<br />
produced via the Sto aluminium starter track and horizontal PVC rails using Sto plastic shims.<br />
3. METSEC lightweight steel frame installed between floor slabs. The frame is clad with two layers of 12.5mm British Gypsum Gyproc<br />
Fireline wallboard on the internal face and 12mm Versapanel sheathing board on the external (cladding) face, the sheathing board is<br />
fixed to the stud <strong>section</strong>s using Euroform EMF 1 5.5 x 50mm fixings at a maximum of 600mm centres.<br />
4. LPCB Ref. No. 749b/01 - StoTherm Mineral M Firebreak details as follows;<br />
a. 200mm high Sto Mineral Lamella fire break along top edge and sides of openings adhered direct to the sheathing board with<br />
additional mechanical fixings (Sto SS fixing screw and washer) at 300mm centres through the reinforcing mesh and firebreak into<br />
the sheathing board.<br />
b. 200mm high continuous horizontal Sto Mineral Fibre Lamella fire break installed using Sto 2 <strong>part</strong> stainless steel Fire Break Rails<br />
which are screwed back to the sheathing board with Sto intumescent strip on lower edge rail, the fire break is additionally affixed<br />
with mechanical fixings (Sto SS fixing screw and washer) at 300mm centres through the reinforcing mesh and firebreak into the<br />
sheathing board. Maximum spacing of continuous fire break; 1500mm above openings and maximum of 2700mm centres<br />
between consecutive breaks.<br />
5. LPCB Ref. No. 749b/02 - StoTherm Mineral M Render, StoArmat Classic base coat with Sto glass fibre Mesh F reinforcing mesh and<br />
Sto Stolit K2,0 top coat, natural or tinted with a PCS value of up to 2.36MJ/kg.<br />
6. LPCB Ref. No. 749b/02 - StoTherm Mineral M insulation boards of nominally 500mm x 500mm fixed to a mechanical rail system with<br />
PVC interlocking vertical T splines, the mechanical rails shall be fixed to the sheathing board with Sto-Screw Rail CS 5.5 x 50 fixings<br />
at a maximum spacing of 300mm. The drainage cavity between the insulation and the masonry substrate is produced via the Sto<br />
aluminium starter track and horizontal PVC rails using Sto plastic shims.<br />
7. LPCB Ref. No. 749b/02 - METSEC lightweight steel frame installed between floor slabs. The frame is clad with two layers of 12.5mm<br />
British Gypsum Gyproc Fireline wallboard on the internal face and 12mm Versapanel sheathing board on the external (cladding) face,<br />
the sheathing board is fixed to the stud <strong>section</strong>s using Euroform EMF 1 5.5 x 50mm fixings at a maximum of 600mm centres.<br />
8. LPCB Ref. No. 749b/02 - StoTherm Mineral M Firebreak details as follows;<br />
a. 200mm high Sto Mineral Lamella fire break along top edge and sides of openings adhered direct to the sheathing board.<br />
b. 500mm high continuous horizontal Sto Mineral Fibre board fire break installed using Sto 2 <strong>part</strong> stainless steel Fire Break Rails<br />
which are screwed back to the sheathing board with Sto intumescent strip on lower edge rail. Maximum continuous fire break<br />
spacing; 1450mm above openings and maximum of 3000mm between consecutive breaks.<br />
74 20 Nov 2011
PART 1: SECTION 2.4.2<br />
LPS 1582 RAIN SCREEN CLADDING SYSTEM (RSC) SUPPORTED BY A STRUCTURAL STEEL FRAME<br />
LPS 1582 Requirements and tests for LPCB approval of non-load bearing external cladding systems fixed to<br />
and supported by a structural steel frame.<br />
This standard is applicable to non-load bearing external rain screen cladding systems fixed to and supported<br />
by a structural steel frame.<br />
The test method used is BS 8414-2: 2005 Test method for non-load bearing external cladding systems fixed<br />
to and supported by a structural steel frame, and is intended to represent the action of a fully developed (post<br />
flashover) fire in a room venting through an opening such as a window aperture, or an external fire source that<br />
exposes the external surfaces of the cladding system to the effects of the impinging flames. The test method<br />
determines external and potential internal and fire spread and, where a void exists, the extent of fire spread<br />
through the void.<br />
Sotech Limited<br />
2 Traynor Way, Whitehouse Business Park, Peterlee, County Durham SR8 2RU, United Kingdom<br />
Tel: +44 (0)191 587 2287 • Fax: +44 (0)191 518 0703<br />
E-mail: mail@sotech-optima.co.uk • Website: www.sotech-optima.co.uk<br />
Certificate No: 770b to LPS 1582 Issue 1.0<br />
Product Name<br />
Sotech Optima<br />
Rainscreen<br />
System<br />
External<br />
layer<br />
detail<br />
Aluminium<br />
cassette see<br />
Note 1<br />
Insulation<br />
material<br />
type &<br />
thickness<br />
100mm<br />
mineral fibre<br />
see Note 2<br />
Frame<br />
type &<br />
boarding<br />
See Note<br />
3<br />
Cavity type<br />
and<br />
maximum<br />
depth (mm)<br />
Cavity of maximum<br />
120mm depth between<br />
rear of cassette system<br />
and face of insulation<br />
Firebreak<br />
detail<br />
See Note<br />
4<br />
EN 13501-1<br />
Classification<br />
No Performance<br />
Determined<br />
Cert.<br />
No.<br />
770b/01<br />
Notes:<br />
1. LPCB Ref. No. 770b/01 - Sotech Optima Rainscreen cassette system consists of aluminium cassette panels precoated with<br />
pvdf to the following scope;<br />
Cassette Panel Material Cassette Height (mm) Maximum Single<br />
Span*(mm)<br />
Aluminium 1.5mm<br />
500 1500<br />
600 1500<br />
750 1500<br />
900 1350<br />
1100 1200<br />
Aluminium 2.0mm<br />
500 1800<br />
600 1800<br />
750 1800<br />
900 1500<br />
1100 1200<br />
Aluminium 3.0mm<br />
500 1800<br />
600 1800<br />
750 1800<br />
900 1600<br />
*Multiple spans are allowable provided that the intermediate supports are installed at centres not exceeding the maximum<br />
single span distances.<br />
2. LPCB Ref. No. 770b/01 – Insulation consists of Rainscreen Duo-slab Mineral fibre, 100mm thick and affixed through the<br />
sheathing board to the SFS with a minimum of one fixing (Ejot 80 SS disc washer T1D-TR2 secured with JT3-D6H screw 5.5-<br />
6.3x147 and HTV-4055 washer) per slab.<br />
3. LPCB Ref. No. 770b/01 – Frame system consists of METSEC SFS 150mm lightweight steel frame stud and track <strong>section</strong>s<br />
installed between floor slabs. External sheathing board; minimum of single layer 12mm Versapanel fixed at 600mm centres.<br />
Internal liner; minimum of two layers 12.5mm British Gypsum Gyproc Fireline boards, staggered lay and fixed at 600mm<br />
centres. The cavity within the SFS is unfilled.<br />
4. LPCB Ref. No. 770b/01 - Fire breaks consist of a horizontal lamella/intumescent strip system located at a maximum height<br />
intervals of 2.5m.<br />
20 Nov 2011 75
PART 1: SECTION 2.5<br />
ROOFING PRODUCTS<br />
The products listed in this <strong>section</strong> are used as roofing systems where there is a risk of fire as follows;<br />
Section 2.5.1 - Protection against fire from outside the building.<br />
Section 2.5.2 - Protection against fire form inside the building.<br />
76 20 Nov 2011
PART 1: SECTION 2.5.1<br />
PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING<br />
The products listed in this <strong>section</strong> are used as roofing systems that offer protection where there is a risk of fire<br />
from outside of the building. The products have been tested against either BS 476:Part 3 Fire tests on building<br />
materials & structures - external fire exposure roof test or ENV 1187:2002 Test methods for external fire<br />
exposure to roofs, in order to ensure that roof covering and its supporting deck act as a protective barrier<br />
against fire from the outside of a building. It should be noted that BS 476: Part 3:1958 has been withdrawn,<br />
but is still referred to in Approved Document B of the UK Building Regulations. ENV 1187:2002 has been<br />
issued as a Draft for Development publication and is of a provisional nature as agreement could not be<br />
reached on the publication of an EN.<br />
Work is currently being undertaken to develop a Loss Prevention Standard for this product group.<br />
Icopal Limited<br />
Barton Dock Road, Stretford, Manchester M32 0YL, United Kingdom<br />
Tel: +44 (0)161 865 4444 • Fax: +44 (0)161 865 8433<br />
E-mail: info@icopal.com • Website: www.icopal.co.uk<br />
Certificate No: 572a to BS 476: Part 3: 1958<br />
Firesmart<br />
Product Name Category Cert. No.<br />
Firesmart Proflex system EXT.F.AA 572a/01<br />
Firesmart Power system EXT.F.AA 572a/03<br />
Firesmart Tecnotorch system EXT.F.AA 572a/05<br />
Firesmart Profiles XL system EXT.F.AA 572a/07<br />
Firesmart Thermaweld EXT.F.AA 572a/09<br />
Notes:<br />
1. The categories specified are applicable only to roofs having a pitch of 10 degrees or less.<br />
2. All products were tested using a 19mm exterior grade plywood deck.<br />
Certificate No: 572b to ENV 1187: 2002 Test 1<br />
ENV 1187: 2002 Test 1<br />
Product Name Category Cert. No.<br />
Firesmart Proflex system EXT.F.AA 572b/01<br />
Firesmart Power system EXT.F.AA 572b/03<br />
Firesmart Tecnotorch system EXT.F.AA 572b/05<br />
Firesmart Profiles XL system EXT.F.AA 572b/07<br />
Firesmart Thermaweld EXT.F.AA 572b/09<br />
Notes:<br />
1. The certification applies to roofs with a pitch of 20 degrees or less.<br />
2. The certification for 572b/01, 572b/03, 572b/07 and 572b/09 covers the systems when applied to any wooden continuous deck with a<br />
minimum thickness of 16mm, and with gaps not exceeding 0.5mm and any non-combustible continuous deck with a minimum<br />
thickness of 10mm.<br />
3. The certification for 572b/05 covers the systems when applied to a 19mm thick exterior grade plywood deck only.<br />
4. The performance of the systems is detailed in the following tables.<br />
20 Nov 2011 77
PART 1: SECTION 2.5.1<br />
PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING<br />
Firesmart Proflex<br />
Firesmart Power<br />
Firesmart Tecnatorch<br />
Firesmart Profiles XL<br />
Firesmart Thermaweld<br />
Specimen<br />
1 2 3 4 1 2 3 4 1 2 3 4<br />
Ext ernal f ire sp read<br />
Time taken to<br />
travel: (in an<br />
upwards<br />
direction from<br />
upper edge of<br />
the brand)<br />
(min:sec)<br />
Time taken to<br />
travel: (in a<br />
downwards<br />
direction from<br />
lower edge of<br />
the brand)<br />
(min:sec)<br />
10cm - - - - - - - - - - - -<br />
30cm - - - - - - - - - - - -<br />
50cm - - - - - - - - - - - -<br />
70cm - - - - - - - - - - - -<br />
to upper edge<br />
of measuring<br />
zone<br />
- - - - - - - - - - - -<br />
10cm 3:29 - 2:33 2:19 2:59 - 2:57 2:06 - - - -<br />
30cm - - - - - - - - - - - -<br />
50cm - - - - - - - - - - - -<br />
to lower edge<br />
of measuring<br />
zone<br />
F alling f laming mat erial<br />
f ro m surf ace o f ro o f<br />
- - - - - - - - - - - -<br />
Time of occurrence (min:sec)<br />
Length of time burning on floor<br />
(min:sec)<br />
B urnt leng t h ( ext ernal)<br />
Upwards (cm)<br />
Downwards (cm)<br />
Damaged area (cm 2 )<br />
- - - - - - - - - - - -<br />
- - - - - - - - - - - -<br />
0 0 0 0 0 0 0 0 0 0 0 0<br />
19 5 21 11 12 5 13 14 6 7 6 7<br />
548 698 554 587 650 697 576 647 645 574 601 557<br />
Firesmart Proflex<br />
Firesmart Power<br />
Firesmart Tecnatorch<br />
Firesmart Profiles XL<br />
Firesmart Thermaweld<br />
Specimen<br />
1 2 3 4 1 2 3 4 1 2 3 4<br />
F ire p enet rat io n<br />
Falling flaming<br />
material from<br />
underside:<br />
Time of<br />
occurrence<br />
(min:sec)<br />
Length of time<br />
burning on floor<br />
(min:sec)<br />
Time of<br />
occurrence<br />
(min:sec)<br />
- - - - - - - - - - - -<br />
- - - - - - - - - - - -<br />
- - - - - - - - - - - -<br />
Nature - - - - - - - - - - - -<br />
Openings<br />
Fire penetration<br />
M aximum area<br />
of a single<br />
opening (cm2)<br />
Sum of area of<br />
all openings<br />
(cm2)<br />
Time of<br />
occurrence<br />
(min:sec)<br />
- - - - - - - - - - - -<br />
- - - - - - - - - - - -<br />
- - - - - - - - - - - -<br />
Nature - - - - - - - - - - - -<br />
78 20 Nov 2011
PART 1: SECTION 2.5.1<br />
PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING<br />
Firesmart Proflex<br />
Firesmart Power<br />
Firesmart Tecnatorch<br />
Firesmart Profiles XL<br />
Firesmart Thermaweld<br />
Specimen<br />
1 2 3 4 1 2 3 4 1 2 3 4<br />
Int ernal d amag e<br />
Non-flaming<br />
propogation<br />
Nature - - - - - - - - - - - -<br />
Extent of<br />
internal damage<br />
(cm2)<br />
Upwards 0 0 0 0 0 0 0 0 0 0 0 0<br />
Downwards 19 5 21 11 12 5 13 14 6 7 6 7<br />
Layer 1:<br />
Upwards 0 0 0 0 0 0 0 0 0 0 0 0<br />
Downwards 19 5 21 11 12 5 13 14 6 7 6 7<br />
Layer 2:<br />
M aximum length<br />
of burnt material<br />
in each<br />
functional layer<br />
(cm2)<br />
Upwards 0 0 0 0 0 0 0 0 0 0 0 0<br />
Downwards 19 5 21 11 12 5 13 14 6 7 6 7<br />
Layer 3:<br />
Upwards 0 0 0 0 0 0 0 0 0 0 0 0<br />
Downwards 19 5 21 11 12 5 13 14 0 0 0 0<br />
Layer 4:<br />
Upwards 0 0 0 0 0 0 0 0 N/A N/A N/A N/A<br />
Downwards 0 0 0 0 0 0 0 0 N/A N/A N/A N/A<br />
Layer 1 548 698 554 587 650 697 576 647 645 574 601 587<br />
Damaged area<br />
of each<br />
functional layer<br />
(cm2)<br />
Layer 2 548 698 554 587 650 697 576 647 645 574 601 587<br />
Layer 3 548 698 554 587 650 697 576 647 98 288 82 159<br />
Ext ent o f lat eral f lame<br />
sp read<br />
Layer 4 200 181 246 210 212 70 276 481 N/A N/A N/A N/A<br />
External (cm)<br />
Internal (cm)<br />
Nil Nil Nil Nil Nil Nil Nil Nil Nil Nil Nil Nil<br />
Nil Nil Nil Nil Nil Nil Nil Nil Nil Nil Nil Nil<br />
IKO PLC<br />
Appley Lane North, Appley Bridge, Wigan, Lancashire WN6 9AB, United Kingdom<br />
Tel: +44 (0)844 412 7207 • Fax: +44 (0)844 412 7208<br />
E-mail: technical@ikogroup.co.uk • Website: www.ikogroup.co.uk<br />
Certificate No: 626a to BS 476: Part 3: 1958<br />
Roofing Products<br />
Product Name Category Cert. No.<br />
Coolbond FireBLOC System EXT.F.AA 626a/01<br />
Superflex FireBLOC system EXT.F.AA 626a/06<br />
Superflex FireBLOC T-O system EXT.F.AA 626a/07<br />
20 Nov 2011 79
PART 1: SECTION 2.5.1<br />
PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING<br />
Product Name Category Cert. No.<br />
Ultra prevENt system EXT.F.AA 626a/08<br />
Ultra prevENt T-O system EXT.F.AA 626a/10<br />
Goldseal FR Roofing System EXT.F.AA 626a/11<br />
Goldseal Torch On Roofing System EXT.F.AA 626a/12<br />
Mach One Single Layer (Cold Adhered) Roofing System EXT.F.AA 626a/14<br />
Mach One Single Layer (Mechanically Fixed) Roofing System EXT.F.AA 626a-13<br />
Notes:<br />
1. All systems specified are applicable only to roofs having a pitch of 10 degrees or less.<br />
2. All systems specified were tested applied to an 18mm exterior grade plywood deck.<br />
3. The supporting substrate may be reinforced (cast insitu) concrete 200mm or pre cast concrete slabs, (screeded), 50-100 mm<br />
screeded Woodwool slabs, profiled metal decking or 20mm timber boards.<br />
4. Systems LPCB Ref. No. 626a/07 Superflex FireBLOC T-O consist of any IKO VCL, Insulation layers Supertherm Universal (53-<br />
103mm), or Supertherm PIR (50-100mm), or SuperRock standard (100-160mm) and IKO Systems T-O underlay.<br />
5. Systems LPCB Ref. No. 626a/06 Superflex FireBLOC consist of any Superbar FireBLOC VCL, Insulation layers Supertherm<br />
Universal (53-103mm), or Enertherm PIR (50-100mm), or SuperRock standard (100-160mm) and Superbase FireBLOC underlay.<br />
6. Systems LPCB Ref. No. 626a/08 Ultra prevENt consist of any IKO Systems VCL, Insulation layers Supertherm Universal (53-<br />
103mm), or Enertherm PIR (50-100mm), or SuperRock standard (100-160mm) and UltraprevENt underlay.<br />
7. Systems LPCB Ref. No. 626a/10 Ultra prevENt T-O consist of any Superbar FireBLOC VCL, Insulation layers Supertherm Universal<br />
(53-103mm), or Supertherm PIR (50-100mm), or SuperRock standard (100-160mm) and Ultra prevENt T-O underlay.<br />
8. The requirements for BS476: Part 3: 1958 will cease when the UK Building Regulations cease to refer to it.<br />
Certificate No: 626b to DD ENV 1187: 2002 - Test Methods for External Fire Exposure to Roofs - Test 1<br />
Roofing Products<br />
Product Name<br />
Cert. No.<br />
Coolbond FireBLOC system 626b/01<br />
Notes:<br />
1. The certification applies to roofs with a pitch of 20 degrees or greater.<br />
2. The certification covers the above systems when applied to a 18mm thick exterior grade plywood deck.<br />
3. The performance of the systems is detailed in the following table.<br />
Time taken to travel:<br />
(in an upw ards<br />
direction from upper<br />
edge of the brand)<br />
(min:sec)<br />
Time taken to travel:<br />
(in a dow nw ards<br />
direction from low er<br />
edge of the brand)<br />
(min:sec)<br />
Specimen<br />
External fire spread<br />
10cm<br />
30cm<br />
50cm<br />
70cm<br />
to upper edge of<br />
measuring zone<br />
10cm<br />
30cm<br />
50cm<br />
to low er edge of<br />
measuring zone<br />
Falling flaming material from surface<br />
of roof<br />
Time of occurrence (min:sec)<br />
Length of time burning on floor (min: sec)<br />
Burnt length (external)<br />
Upw ards (cm)<br />
Dow nw ards (cm)<br />
Damaged area (cm 2 )<br />
1 2 3 4<br />
_<br />
_<br />
_<br />
_<br />
_<br />
1:56<br />
2:30<br />
_<br />
_<br />
Coolbond FireBLOC system<br />
_<br />
_<br />
_<br />
_<br />
_<br />
1:25<br />
2:17<br />
_<br />
_<br />
5:59<br />
_<br />
_<br />
_<br />
_<br />
1:49<br />
2:28<br />
_<br />
_<br />
_<br />
_<br />
_<br />
_<br />
_<br />
1:54<br />
5:05-<br />
_<br />
- - - -<br />
- - - -<br />
2 3 10 0<br />
30 30 30 30<br />
700 600 700 800<br />
_<br />
80 20 Nov 2011
PART 1: SECTION 2.5.1<br />
PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING<br />
Specimen<br />
Coolbond FireBLOC system<br />
1 2 3 4<br />
Fire penetration<br />
Time of occurrence<br />
(min:sec) - - - -<br />
Falling flaming<br />
material from<br />
underside:<br />
Length of time<br />
burning on floor<br />
(min:sec)<br />
- - - -<br />
Time of occurrence<br />
(min:sec) - - - -<br />
Nature<br />
Maximum area of a<br />
single opening<br />
(cm 2 )<br />
- - - -<br />
Sum of area of all<br />
openings<br />
(cm 2 )<br />
- - - -<br />
Openings<br />
- - - -<br />
Time of occurrence<br />
(min:sec) - - - -<br />
Fire penetration<br />
Nature<br />
- - - -<br />
20 Nov 2011 81
PART 1: SECTION 2.5.1<br />
PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING<br />
Specimen<br />
Internal damage<br />
Non-flaming<br />
propagation Extent of<br />
internal damage<br />
(cm)<br />
1 2 3 4<br />
Nature _ _ _ _<br />
Upwards<br />
Downwards<br />
Layer 1:<br />
Upwards<br />
Downwards<br />
Coolbond FireBLOC system<br />
_<br />
19<br />
_<br />
19<br />
_<br />
18<br />
_<br />
18<br />
_<br />
28<br />
_<br />
28<br />
_<br />
27<br />
_<br />
27<br />
Maximum length<br />
of burnt material<br />
in each functional<br />
layer (cm)<br />
Layer 2:<br />
Upwards<br />
Downwards<br />
_<br />
8<br />
_<br />
18<br />
_<br />
16<br />
_<br />
27<br />
Layer 3:<br />
Updwards<br />
Downwards<br />
_<br />
8<br />
_<br />
5<br />
_<br />
5<br />
_<br />
16<br />
Damaged area of<br />
each functional<br />
layer<br />
(cm2)<br />
Layer 1<br />
Layer 2<br />
Layer 3<br />
700<br />
500<br />
400<br />
500<br />
500<br />
500<br />
700<br />
600<br />
500<br />
700<br />
700<br />
600<br />
Extent of lateral flame spread<br />
External (cm)<br />
Internal (cm)<br />
Nil Nil Nil Nil<br />
Nil Nil Nil Nil<br />
Certificate No: 626c to DD ENV 1187: 2002 Test 2<br />
Roofing Products<br />
Product Name<br />
Cert. No.<br />
Coolbond FireBLOC system 626c/01<br />
Notes:<br />
1) The certification applies to roofs with any pitch.<br />
2) The certification covers the above systems when applied to a 18mm thick exterior grade plywood deck.<br />
3) The performance of the systems is detailed in the following tables.<br />
626c/01 Coolbond FireBLOC system<br />
Specimen 1 2 3 4 5 6 Average<br />
Air velocity 2 m/s 2 m/s 2 m/s 4 m/s 4 m/s 4 m/s N/A<br />
Time at which specimen ignited 00:54 00:51 00:50 00:48 00:38 00:41 00:47<br />
(min:sec)<br />
Time at which flaming of specimen 08:53 08:49 04:29 04:56 04:15 04:10 05:55<br />
ceased (min:sec)<br />
Time at which glowing of specimen N/A N/A N/A N/A N/A N/A -<br />
ceased (min:sec)<br />
Test termination time (min:sec) 15:00 15:00 15:00 15:00 15:00 15:00 15:00<br />
Reason for termination (if applicable) N/A N/A N/A N/A N/A N/A -<br />
Extent of damage to roof covering 360 360 410 385 390 360 378<br />
Extent of damage (mm) to substrate (mm) 0 0 0 0 0 0 0<br />
Damaged area of roof covering (mm2) 31000 31000 36000 34000 34500 32000 33084<br />
Damaged area of substrate (mm2) 0 0 0 0 0 0 0<br />
Maximum depth of damage (mm) 3 3 3 3 3 3 3<br />
82 20 Nov 2011
PART 1: SECTION 2.5.1<br />
PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING<br />
Permanite Asphalt<br />
Cawdor Quarry, Matlock, Derbyshire DE4 2JH, United Kingdom<br />
Tel: +44 (0)1629 582213 • Fax: +44 (0)1629 583375<br />
E-mail: roof.tech@permanite.com • Website: www.permanite.com<br />
Certificate No: 666a to BS 476: Part 3: 1958<br />
Permaphalt<br />
Product Name Category Cert. No.<br />
Permaphalt Category EXT.F.AA 666a/01<br />
Notes:<br />
1. The Categories specified are applicable only to roofs having a pitch of 10 degrees or less.<br />
2. The test specimen had 2 layers of Permaphalt to a total thickness of 20mm.<br />
3. The product was tested separately with 90mm thick Supertherm PIR and 135mm thick Rockwool HD insulation board.<br />
4. All tests used a 18mm exterior grade plywood deck.<br />
5. The requirement for BS476: Part 3: 1958 will cease when the Building Regulations cease to refer to it.<br />
20 Nov 2011 83
PART 1: SECTION 2.5.2<br />
PROTECTION AGAINST FIRE FROM INSIDE THE BUILDING<br />
The products listed in this <strong>section</strong> are built-up roofing systems which offer protection against the risk of fire<br />
from within the building. The products have been tested to:<br />
<br />
or<br />
<br />
or<br />
<br />
or<br />
<br />
BS 476:Part 21 Fire tests on building materials & structures. Methods for determination of the fire<br />
resistance of loadbearing elements of construction<br />
BS 476:Part 22 Fire tests on building materials & structures. Methods for determination of the fire<br />
resistance of non-loadbearing elements<br />
EN 1364:Part 2 Fire resistance tests for non-loadbearing elements. Ceilings<br />
EN 1365:Part 2 Fire resistance tests for loadbearing elements. Floors & roofs and meet the<br />
requirements of LPS 1208 for fire resistance (For roof sandwich panels, see Section <strong>2.2</strong>.)<br />
Rockwool Limited<br />
Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom<br />
Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302<br />
E-mail: info@rockwool.co.uk • Website: www.rockwool.co.uk<br />
Certificate No: 022a to BS 476: Part 21: Method 7 (see note 1)<br />
Product Name<br />
Specification<br />
System<br />
Thickness<br />
(mm) (1)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Core<br />
Material<br />
Cert. No.<br />
Hardrock DD roofing board 210 120 120 Stone Wool 022a/01<br />
100 - 135 60 60 Stone Wool<br />
140 - 205 90 90 Stone Wool<br />
Hardrock DD SPA roofing board 210 120 120 Stone Wool 022a/02<br />
100 - 135 60 60 Stone Wool<br />
140 - 205 90 90 Stone Wool<br />
DuoRock roofing board 100 - 210 60 60 Stone Wool 022a/03<br />
Note:<br />
1. Roof board system LPCB Ref No. 022a/01 & LPCB Ref No. 022a/03: Mechanically fastened Sarnafil single ply type S327-12EL<br />
(1.2mm thickness), external weather proof membrane (or alternative membrane less than 3.5 kg/m² e.g. PVC, Chlorinated PE, Butyl<br />
Rubber with welded seams);<br />
Comprising of two layers of Rockwool roofing board with staggered joints (100mm minimum stagger for fire resistance up to 90<br />
minutes and 300mm stagger for 2 hours fire resistance), vapour control layer and 0.7mm thickness 35mm deep profile steel metal<br />
deck.<br />
Roof board system LPCB Ref No. 022a/02: Sarnafil single ply external weather proof membrane type G410-12EL (1.2mm thickness),<br />
fully adhered to Hardrock DD SPA roof board system with Sarnifil Adhesive(or Rockwool approved alternative adhesive/membrane<br />
combination, with a membrane material less than 3.5 kg/m² e.g. PVC, Chlorinated PE, Butyl Rubber with welded seams); comprising<br />
of two layers of Rockwool roofing board with staggered joints (100mm minimum stagger for fire resistance up to 90 minutes and<br />
300mm stagger for 2 hours fire resistance), vapour control layer and 0.7mm thickness 35mm deep profile steel metal deck.<br />
The test construction was tested unloaded. However, deflection of the roof did not exceed the allowable limits set out in BS 476: Part<br />
20: 1987 for loadbearing horizontal elements. Decking side laps were stitched at 450mm centres.<br />
Roof Board System LPCB Ref No 022a/01, 022a/02 & 022a/03 Hardrock DD, Hardrock DD SPA and DuoRock roofing boards are<br />
also available and approved in cut-to-fall tapered options, the relevant minimum & maximum system thickness and staggered joints<br />
shall apply as detailed above.<br />
84 20 Nov 2011
PART 1: SECTION 2.6<br />
REACTION TO FIRE (RTF) CLASSIFICATIONS FOR MATERIALS AND PRODUCTS<br />
The materials and products listed in this <strong>section</strong> are LPCB approved and classified to one of the following<br />
Reaction to Fire (RTF) classification systems:<br />
<br />
Non-combustible to BS 476-4 Fire tests on building materials and structures. Non-combustibility test<br />
for materials.<br />
Class O as defined in Approved Document B - Fire Safety, The Building Regulations 2000.<br />
<br />
BS EN 13501-1 Fire classification of construction products and building elements. Classification using<br />
test data from reaction to fire tests. Note: LPCB approvals under this standard are limited to materials<br />
or products resulting in a classification of A1, A2 or B. Products under A2 or B will also be classified in<br />
relation to the additional classifications of s and d (eg s3, d2).<br />
Rockwool Limited<br />
Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom<br />
Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302<br />
E-mail: info@rockwool.co.uk • Website: www.rockwool.co.uk<br />
Certificate No: 022e to EN 13501-1: 2002<br />
Rockwool Non-combustible Insulation Materials<br />
Product Name<br />
Thickness<br />
(mm)<br />
Test/Assessment<br />
Standard<br />
Classification Cert.<br />
No.<br />
Cladding Roll - Aluminium Foil Faced 60 - 180 EN 13501-1: 2002 A1 022e/01<br />
Cladding Roll - Unfaced 60 - 180 EN 13501-1: 2002 A1<br />
Cladding Roll - White Tissue Faced 60 - 180 EN 13501-1: 2002 A1<br />
Cavity Batts - Unfaced 50 - 150 EN 13501-1: 2002 A1 022e/02<br />
Rainscreen Duo Slabs - Black Tissue Faced 50 - 125 EN 13501-1: 2002 A1 022e/03<br />
Rainscreen Duo Slabs - Unfaced 50 -125 EN 13501-1: 2002 A1<br />
Flexi Batts - Unfaced 50 - 150 EN 13501-1: 2002 A1 022e/04<br />
Hardrock Dual Density Roofing Boards - Black Tissue 50 - 155 EN 13501-1: 2002 A1 022e/05<br />
Faced<br />
Hardrock Dual Density Roofing Boards - Unfaced 50 - 155 EN 13501-1: 2002 A1<br />
Hardrock Dual Density Roofing Boards - White Tissue 50 - 155 EN 13501-1: 2002 A1<br />
Faced<br />
DuoRock Roofing Boards - Black Tissue Faced 50 - 180 EN 13501-1: 2002 A1 022e/06<br />
DuoRock Roofing Boards - Unfaced 50 - 180 EN 13501-1: 2002 A1<br />
DuoRock Roofing Boards - White Tissue Faced 50 - 180 EN 13501-1: 2002 A1<br />
Superglass Insulation Limited<br />
Thistle Industrial Estate, Kerse Road, Stirling FK7 7RW, United Kingdom<br />
Tel: +44 (0)1786 451170 • Fax: +44 (0)1786 451245<br />
E-mail: technical@superglass.org.uk • Website: www.superglass.co.uk<br />
Certificate No: 472a to BS 476: Part 4<br />
Thermaquilt and Superglass Cladding Mat<br />
Product Name<br />
Thickness Test/Assessment<br />
Classification Cert. No.<br />
(mm)<br />
Standard<br />
Thermaquilt 50 - 200 BS 476:Part 4 Non-combustible 472a/01<br />
Superglass Cladding Mat 60 - 200 BS 476:Part 4 Non-combustible 472a/02<br />
20 Nov 2011 85
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
The following products have been approved to LPS 1132 Requirements and tests for LPCB approval of wall &<br />
floor penetration & linear gap seals to help ensure fire resisting com<strong>part</strong>ment walls and floors are not<br />
compromised by the installation of building services that pass between fire resisting com<strong>part</strong>ments.<br />
The design requirements for these products are described in more detail in Section 4.6 of the LPC Design<br />
Guide for the Fire Protection of Buildings: 2000.<br />
DST Group Ltd<br />
Design House, 2C Southgate, White Lund, Morecombe, Lancs LA3 3PB, United Kingdom<br />
Tel: +44 (0)1524 389494 • Fax: +44 (0)1524 389495<br />
E-mail: sales@dstgroup.co.uk • Website: www.dstgroup.co.uk<br />
Certificate No: 873a to LPS 1132: Issue 4.1<br />
Fire Sleeve Pipe Wraps<br />
Product<br />
Use<br />
Name<br />
Fire Sleeve<br />
Pipe Wraps<br />
uPVC Pipes up to 167mm<br />
diameter<br />
uPVC Pipes from 167mm to<br />
225mm diameter<br />
ABS pipes up to 114mm<br />
diameter<br />
Polypropylene pipes up to<br />
16mm diameter<br />
Polypropylene pipes from<br />
16mm to 160 mm diameter<br />
Polypropylene pipes from<br />
160mm to 225mm diameter<br />
Polyethylene pipes up to<br />
225mm diameter<br />
Steel pipes up to 220mm<br />
diameter<br />
Copper pipes up to 76mm<br />
diameter<br />
Element of<br />
construction<br />
Concrete, masonry<br />
or drywall<br />
Concrete, masonry<br />
or drywall<br />
Concrete, masonry<br />
or drywall<br />
Concrete, masonry<br />
or drywall<br />
Concrete, masonry<br />
or drywall<br />
Concrete, masonry<br />
or drywall<br />
Concrete, masonry<br />
or drywall<br />
Concrete, masonry<br />
or drywall<br />
Concrete, masonry<br />
or drywall<br />
Element of<br />
construction<br />
thickness<br />
minimum<br />
(mm)<br />
Fire<br />
resistance<br />
(min)<br />
Integrity<br />
Fire<br />
resistance<br />
(min)<br />
Insulation<br />
Cert.<br />
No.<br />
130 120 Not assessed 873a/01<br />
130 120 Not assessed<br />
130 120 Not assessed<br />
130 120 Not assessed<br />
130 90 Not assessed<br />
130 60 Not assessed<br />
130 120 Not assessed<br />
130 120 Not assessed<br />
130 120 Not assessed<br />
Note:<br />
The fire performance of the system will be dependent on the diameter and wall thickness of the pipe and installed location as detailed in<br />
the tables above. The shell of the pipe wrap assembly shall be sealed in the element of construction by a bead of DST Group<br />
intumescent mastic/sealant with a minimum fire rating of 2 hours. Reference should be made to manufacturers’ literature and BRE Global<br />
assessment report CC241402 for further information<br />
Hilti Aktiengesellschaft<br />
Feldkircher Strasse 100, Postfach 333, FL-9494 Schaan, Liechtenstein<br />
Tel: +423 234 3004 • Fax: +423 234 2674<br />
E-mail: fs-ej-team@hilti.com • Website: www.hilti.com<br />
UK Sales: Hilti (G.B.) Limited<br />
1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY, United Kingdom<br />
Tel: +44 (0)161 886 1000 • Fax: +44 (0)161 786 3890<br />
Certificate No: 090a(3) to LPS 1132: Issue 4<br />
86 20 Nov 2011
CP 611A - LPCB Ref. No.: 090a(3)<br />
Product<br />
Name<br />
CP<br />
611A<br />
Element of<br />
construction<br />
orientation<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Configuration:<br />
fire side<br />
Configuration:<br />
middle<br />
Configuration:<br />
non-fire side<br />
Use<br />
Cables<br />
Use<br />
Trays<br />
Use<br />
Pipes<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity /<br />
Insulation<br />
Wall 100+ Drywall 25mm CP611A No filling 30mm CP611A Yes No No 120 / 60 090a/01<br />
Wall / Floor 110+ L W<br />
Concrete<br />
Wall / Floor 150+ L W<br />
Concrete<br />
Wall / Floor 150+ L W<br />
Concrete<br />
Wall / Floor 150+ L W<br />
Concrete<br />
Wall / Floor 150+ L W<br />
Concrete<br />
Wall / Floor 150+ L W<br />
Concrete<br />
Wall / Floor 150+ Reinforced<br />
vermiculite<br />
concrete<br />
Wall 100+ L W<br />
Concrete<br />
Wall 100+ L W<br />
Concrete<br />
Floor 120+ Reinforced<br />
autoclaved<br />
aerated<br />
concrete<br />
slabs<br />
minimum<br />
density<br />
670kg/m³<br />
Floor 120+ Reinforced<br />
autoclaved<br />
aerated<br />
concrete<br />
slabs<br />
minimum<br />
density<br />
670kg/m³<br />
50mm CP611A N/A 60mm<br />
rockwool<br />
Yes Yes No 30 / 30<br />
50mm CP611A 50mm 50mm CP611A Yes Yes No 90 / 60<br />
rockwool<br />
10mm CP611A 130mm 10mm CP611A Yes No No 240 / 90<br />
rockwool<br />
30mm CP611A 90mm 30mm CP611A Yes No No 240 / 30<br />
rockwool<br />
20mm CP611A 110mm 20mm CP611A Yes No No 240 / 30<br />
rockwool<br />
110mm<br />
N/A 40mm CP611A Yes Yes No 120 / 90<br />
rockwool<br />
40mm CP611A N/A 110mm Yes Yes No 120 / 90<br />
rockwool<br />
60mm CP611A N/A N/A No No PVC<br />
pipe<br />
40mm<br />
Ø<br />
x3mm<br />
thick<br />
N/A N/A 60mm CP<br />
611A<br />
No No PVC<br />
pipe<br />
40mm<br />
Ø<br />
x3mm<br />
thick<br />
80mm CP611A N/A N/A No No PVC<br />
pipe<br />
40mm<br />
Ø<br />
x3mm<br />
thick<br />
N/A N/A 80mm CP611A No No PVC<br />
pipe<br />
40mm<br />
Ø<br />
x3mm<br />
thick<br />
240 / 240<br />
240 / 240<br />
180 / 120<br />
180 / 180<br />
Cert.<br />
No.<br />
Note:<br />
Please refer to installation instructions for further details.<br />
Certificate No: 090a(2) to LPS 1132: Issue 4<br />
CP 636 - LPCB Ref. No.: 090a(2)<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Element of<br />
construction<br />
thickness/material<br />
CP 636 Floor 150mm+ Aerated<br />
Concrete<br />
Floor 150mm+ Aerated<br />
Concrete<br />
Configuration:<br />
fire side<br />
Configuration:<br />
non-fire side<br />
Use:<br />
cables<br />
Use:<br />
trays<br />
Use:<br />
conduit<br />
pipes<br />
Aperture<br />
Size<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
(I)<br />
N/A 150mm CP636 Yes Yes Yes 1000x600 180 90 532a/01<br />
50mm mineral<br />
fibre<br />
(140kg/m 3 )<br />
75mm CP636 Yes Yes No 600x600 240 90<br />
Wall 150mm+ Masonry N/A 150mm CP636 Yes Yes Yes 2000x1200 20 120<br />
Wall 120mm+ Masonry N/A 100mm CP636 Yes Yes No 600x600 240* 60*<br />
Wall 200mm+ Masonry N/A 185mm CP636 Yes Yes Yes 1200x600 240 60<br />
Cert.<br />
No.<br />
Note:<br />
* To achieve this fire resistance the penetrations should be coated with a 30mm wide x 0.5mm thick layer of Hilti CP611A where they<br />
pass through the wall. The coated <strong>section</strong> should be positioned centrally within the wall thickness.<br />
Certificate No: 090a(1) to LPS 1132: Issue 4<br />
20 Nov 2011 87
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
CP 601S - LPCB Ref. No.: 090a(1)<br />
Product<br />
Name<br />
CP<br />
601S<br />
Element of<br />
construction<br />
orientation<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
Configuration:<br />
fire side<br />
Configuration:<br />
middle<br />
Floor 150+ L W Concrete 20mm CP601S 110mm mineral<br />
fibre<br />
(100kg/m 3 )<br />
Floor 150+ L W Concrete 20mm CP601S 110mm mineral<br />
fibre<br />
(100kg/m 3 )<br />
Floor 150+ L W Concrete 20mm CP601S 110mm mineral<br />
fibre<br />
(100kg/m 3 )<br />
Wall 100+ L W Concrete 20mm CP601S 60mm mineral<br />
fibre<br />
(100kg/m 3 )<br />
Wall 100+ L W Concrete 20mm CP601S 60mm mineral<br />
fibre<br />
(100kg/m 3 )<br />
Wall 100+ L W Concrete 20mm CP601S 60mm mineral<br />
fibre<br />
(100kg/m 3 )<br />
Configuration:<br />
non-fire<br />
side<br />
20mm<br />
CP601S<br />
20mm<br />
CP601S<br />
20mm<br />
CP601S<br />
20mm<br />
CP601S<br />
20mm<br />
CP601S<br />
20mm<br />
CP601S<br />
Use<br />
Copper<br />
pipes<br />
42-<br />
200mm<br />
dia.<br />
1.25-<br />
10.0mm<br />
wall<br />
Copper<br />
pipes<br />
42-<br />
200mm<br />
dia.<br />
1.25-<br />
10.0mm<br />
wall<br />
Copper<br />
pipes<br />
42-<br />
50mm<br />
dia.<br />
1.25-<br />
10.0mm<br />
wall<br />
Copper<br />
pipes<br />
42-<br />
200mm<br />
dia.<br />
1.25-<br />
10.0mm<br />
wall<br />
Copper<br />
pipes<br />
42-<br />
200mm<br />
dia.<br />
1.25-<br />
10.0mm<br />
wall<br />
Copper<br />
pipes<br />
42-<br />
50mm<br />
dia.<br />
1.25-<br />
10.0mm<br />
wall<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
(I)<br />
Cert.<br />
No.<br />
120 0 520a/01<br />
240 0<br />
240 0<br />
120 0<br />
240 0<br />
240 0<br />
Note:<br />
1. Product used as a pipe penetration sealant.<br />
Certificate No: 090a(1) to LPS 1132: Issue 4<br />
CP 601S - LPCB Ref. No.: 090a(1)<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
Dept of<br />
CP620<br />
(mm)<br />
(notes<br />
2 & 5)<br />
Fire<br />
Side<br />
Penetration<br />
Size<br />
(notes 1, 3,<br />
4)<br />
CP 601S Floor 150+ L W concrete 15 N/A 144mm mineral<br />
fibre (100kg/m 3 )<br />
Floor 150+ L W concrete 30 N/A 135mm mineral<br />
fibre (100kg/m 3 )<br />
Floor 150+ L W concrete 100 N/A 135mm mineral<br />
fibre (100kg/m 3 )<br />
Wall 100+ L W concrete 30 15mm 70mm mineral<br />
CP601S fibre (100kg/m 3 )<br />
Wall 100+ L W concrete 12 10mm 12mm dia PE<br />
CP601S<br />
rod<br />
Floor 150+ L W Concrete 50mm 20mm 50mm dia. PE<br />
CP601S<br />
rod<br />
Floor 150+ L W Concrete 10mm 6mm 15mm dia. PE<br />
CP601S<br />
rod<br />
Floor 150+ L W Concrete 30mm N/A 35mm dia. PE<br />
rod<br />
Floor 150+ L W Concrete 10mm N/A 15mm dia. PE<br />
rod<br />
Wall 150+ L W Concrete 50mm 20mm 50mm dia. PE<br />
CP601S<br />
rod<br />
Wall 150+ L W Concrete 10mm 6mm 15mm dia. PE<br />
CP601S<br />
rod<br />
Wall 150+ L W Concrete 30mm N/A 35mm dia. PE<br />
rod<br />
Wall 150+ L W Concrete 10mm N/A 15mm dia. PE<br />
rod<br />
Non-Fire<br />
Side<br />
6mm<br />
CP601S<br />
15mm<br />
CP601S<br />
15mm<br />
CP601S<br />
15mm<br />
CP601S<br />
10mm<br />
CP601S<br />
20mm<br />
CP601S<br />
6mm<br />
CP601S<br />
15mm<br />
CP601S<br />
6mm<br />
CP601S<br />
20mm<br />
CP601S<br />
6mm<br />
CP601S<br />
15mm<br />
CP601S<br />
6mm<br />
CP601S<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
(I)<br />
Cert.<br />
No.<br />
240 240 520a/01<br />
240 240<br />
240 240<br />
120 120<br />
120 120<br />
240 240<br />
240 240<br />
240 120<br />
240 240<br />
240 240<br />
240 240<br />
240 90<br />
240 240<br />
88 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Note:<br />
1. Product used as a linear gap seal<br />
Certificate No: 090a(5) to LPS 1132: Issue 4<br />
CP 620 Expanding Firestop Foam - LPCB Ref No.: 090a(5)<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
CP 620 Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
drywall<br />
Wall 100 concrete,<br />
masonry or<br />
Depth<br />
of<br />
CP620<br />
(mm)<br />
(notes<br />
2 & 5)<br />
Penetration<br />
Type<br />
(notes<br />
1, 3, 4)<br />
Penetration<br />
Size<br />
Integrity Insulation Cert.<br />
No.<br />
145 copper pipe 76mm dia 120 0 090a/03<br />
200 copper pipe<br />
+ insulation<br />
76mm dia +<br />
insulation<br />
thickness<br />
120 120<br />
145 steel pipe 76mm dia 120 30<br />
145 steel pipe +<br />
insulation<br />
114mm dia<br />
+ insulation<br />
thickness<br />
120 120<br />
145 PVC pipe 110mm dia 120 120<br />
200 PE pipe 50mm dia 120 120<br />
200 PE pipe 110mm dia 120 120<br />
200 ABS pipe 110mm dia 120 120<br />
200 single cable<br />
or cable<br />
bundle<br />
145 cable<br />
bundle<br />
drywall<br />
Wall 120 drywall 120 copper pipe<br />
+ insulation<br />
Wall 120 drywall 120 cable<br />
trunking<br />
(Note 6)<br />
70mm dia 120 120<br />
100mm dia 120 60<br />
145 cable tray 150 x 25mm 120 120<br />
200 cable tray 250 x 25mm 120 120<br />
77mm dia +<br />
insulation<br />
thickness<br />
100 x<br />
100mm<br />
120 60<br />
120 60<br />
Wall 120 drywall 120 PVC pipe 100mm dia 120 60<br />
Wall 120 drywall 120 cable tray 150 x 25mm<br />
150 x 25mm<br />
150 x 25mm<br />
120 60<br />
Floor 150 LW Concrete 200 cable tray 320 x 60mm 150 60<br />
Floor 150 LW Concrete 150 copper pipe 89mm dia + 150 120<br />
+ insulation insulation<br />
thickness<br />
Floor 150 LW Concrete 200 PVC pipe 50mm dia 150 90<br />
Floor 150 LW Concrete 200 PVC pipe 100mm dia 150 90<br />
Floor 150 LW Concrete 200 steel pipe + 114mm dia 150 90<br />
insulation + insulation<br />
thickness<br />
Floor 150 LW Concrete 150 cable tray 320 x 60mm 120 30<br />
Floor 150 LW Concrete 150 PVC pipe 50mm dia 120 60<br />
Floor 150 LW Concrete 150 PVC pipe 100mm dia 120 60<br />
20 Nov 2011 89
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
Depth<br />
of<br />
CP620<br />
(mm)<br />
(notes<br />
2 & 5)<br />
Penetration<br />
Type<br />
(notes<br />
1, 3, 4)<br />
Floor 150 LW Concrete 150 steel pipe +<br />
insulation<br />
Penetration<br />
Size<br />
114mm dia<br />
+ insulation<br />
thickness<br />
Integrity Insulation Cert.<br />
No.<br />
120 60<br />
Notes:<br />
1. The penetrating services should be installed with a minimum separation of 100mm from any other penetrating service and a minimum<br />
distance of 50mm from the edge of the seal.<br />
2. An additional bead of 25x25mm of CP620 should be applied around each service (except plastic pipes where it penetrates each face<br />
of the seal.<br />
3. Plastic pipes (PE, PVC or ABS) must be fitted with Hilti CP643 pipe collars.<br />
4. Please refer to manufacturer’s installation instructions for more details.<br />
5. For seals thicker than the supporting wall, a framework should be installed using type 5 plasterboard. Refer to manufacturer’s<br />
instructions for further details.<br />
6. Cable trunking tested with 30% fill of 12mm diameter cables and packed with CP651 cushions above cables at the location where the<br />
service passed through the <strong>part</strong>ition.<br />
Certificate No: 090a(6) to LPS 1132: Issue 4<br />
CF 125-50 Penetration Seals - LPCB Ref No.: 090a(6)<br />
Product<br />
Configuration:<br />
Name<br />
fire side<br />
CF 125-<br />
50<br />
Element of<br />
construction<br />
orientation<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Wall 150 Nominal<br />
1mm<br />
coating of<br />
CP671<br />
Configuration:<br />
middle<br />
150mm<br />
CF 125-50<br />
Configuration:<br />
non-fire<br />
side<br />
Nominal<br />
1mm<br />
coating<br />
of CP671<br />
Use<br />
300 x<br />
300mm<br />
aperture in<br />
LW<br />
blockwork<br />
containing:<br />
225 x<br />
26mm<br />
steel cable<br />
types 5-<br />
25mm dia.<br />
50mm<br />
galvanised<br />
steel<br />
pipe with<br />
4.2mm<br />
wall<br />
thickness<br />
Integrity<br />
(minutes)<br />
Insulation<br />
(minutes)<br />
Cert.<br />
No.<br />
30 30 090a/04<br />
Certificate No: 090a(6) to LPS 1132: Issue 4<br />
CF 125-50 Linear Gap Seals - LPCB Ref No.: 090a(6)<br />
Product<br />
Configuration:<br />
Name<br />
fire side<br />
CF 125-<br />
50<br />
Element of<br />
construction<br />
orientation<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Wall 100 900 x 15mm<br />
CF125-50<br />
Wall 100 900 x 15mm<br />
CF125-50<br />
Configuration:<br />
middle<br />
Configuration:<br />
non-fire<br />
side<br />
Use<br />
N/A N/A seal<br />
between<br />
softwood<br />
and LW<br />
blockwork<br />
N/A N/A seal<br />
between<br />
softwood<br />
and<br />
common<br />
brickwork<br />
Integrity<br />
(minutes)<br />
Insulation<br />
(minutes)<br />
Cert.<br />
No.<br />
120 120 090a/04<br />
150 120<br />
90 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Configuration:<br />
fire side<br />
Wall 150 Nominal<br />
1mm<br />
coating of<br />
CP671<br />
Wall 200 950x 135 x 20<br />
mm CF125-50<br />
Configuration:<br />
middle<br />
900 x 50mm<br />
CF125-50<br />
N/A<br />
Configuration:<br />
non-fire<br />
side<br />
Nominal<br />
1mm<br />
coating<br />
of CP671<br />
15mm<br />
CP606<br />
mastic<br />
Use<br />
seal<br />
between<br />
mortar<br />
lintel<br />
and steel<br />
deck<br />
seal<br />
between<br />
concrete<br />
faces<br />
Wall 100 950 x 15mm N/A N/A seal<br />
between<br />
concrete<br />
faces<br />
Wall 100 Up to 25mm<br />
dia. Holes<br />
Floor 150 950 x 135 x 20<br />
mm CF125-<br />
50<br />
N/A N/a seal<br />
between<br />
concrete<br />
faces<br />
N/A<br />
15mm<br />
CP606<br />
mastic<br />
seal<br />
between<br />
concrete<br />
faces<br />
Integrity<br />
(minutes)<br />
Insulation<br />
(minutes)<br />
150 120<br />
240 120<br />
120 120<br />
120 120<br />
240 180<br />
Cert.<br />
No.<br />
Certificate No: 090a(8) to LPS1132: Issue 4<br />
CP 606 Intumescent Mastic - Penetration Seals - LPCB Ref No.: 090a(8)<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Configuration:<br />
gap size<br />
(mm)<br />
Configuration:<br />
fire side<br />
Configuration:<br />
middle<br />
Configuration:<br />
non-fire side<br />
CP 606<br />
100mm AC<br />
wall<br />
150mm AC<br />
floor<br />
100mm AC<br />
wall with<br />
cylindrical<br />
steel sleeve<br />
N/A 20mm CP606 60mm<br />
Rockfibre<br />
100kg/m 3<br />
N/A<br />
Max<br />
30mm<br />
80mm<br />
Rockfibre/m 3<br />
100kg/m 3<br />
density<br />
70mm<br />
Rockfibre<br />
140kg/m 3<br />
density<br />
density<br />
20mm CP606<br />
Use<br />
42mm<br />
copper<br />
pipe<br />
with<br />
1.25mm<br />
wall<br />
thickness<br />
N/A 20mm CP606 42mm<br />
copper<br />
pipe<br />
with<br />
1.25mm<br />
wall<br />
thickness<br />
N/A 15mm CP606 Up to<br />
600mm<br />
steel<br />
pipe<br />
with<br />
minimum<br />
3mm<br />
wall<br />
thickness<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
Cert.<br />
No.<br />
240 0 090a/07<br />
240 0<br />
240 0<br />
Certificate No: 090a(8) to LPS1132: Issue 4<br />
CP 606 Intumescent Mastic - Linear Gap Seals - LPCB Ref No.: 090a(8)<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Gap Size<br />
(mm)<br />
Configuration:<br />
fire side<br />
Configuration:<br />
middle<br />
Configuration:<br />
non-fire side<br />
CP 606<br />
150mm<br />
AC/AC floor<br />
Up to<br />
15<br />
30mm PE<br />
foam rod<br />
Use<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
Cert.<br />
No.<br />
N/A 60mm CP606 120 60 090a/07<br />
20 Nov 2011 91
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
150mm<br />
AC/AC floor<br />
150mm<br />
AC/AC floor<br />
150mm<br />
AC/AC floor<br />
Vertical<br />
linear gap<br />
between<br />
150mm AC<br />
blockwork<br />
wall minimum<br />
density<br />
760kg/m³<br />
/Galvanised<br />
Mild steel<br />
angle<br />
150mm x<br />
20mm x<br />
2mm thick<br />
Vertical<br />
linear gap<br />
between<br />
150mm AC<br />
blockwork<br />
wall minimum<br />
density<br />
760kg/m³ /<br />
Galvanised<br />
mild steel<br />
angle<br />
150mm x<br />
20mm x 2mm<br />
thick<br />
Horizontal<br />
linear gap<br />
between<br />
150mm AC<br />
blockwork<br />
wall minimum<br />
density<br />
760kg/m³ /<br />
Galvanised<br />
mild steel<br />
angle<br />
150mm x<br />
20mm x 2mm<br />
thick<br />
150mm<br />
AC/AC floor<br />
150mm<br />
AC/AC floor<br />
Gap Size<br />
(mm)<br />
15 to<br />
30<br />
Configuration:<br />
fire side<br />
30mm PE<br />
foam rod<br />
Up to 135mm of<br />
15 CF125-50<br />
15 to 30 135mm of<br />
CF125-50<br />
30mm<br />
10mm CP606<br />
& 25mm Ø PE<br />
backing rod<br />
Configuration:<br />
middle<br />
Configuration:<br />
non-fire side<br />
Use<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
N/A<br />
10mm of<br />
CP606 for<br />
gaps of<br />
15mm.<br />
15mm of<br />
CP606 for<br />
gaps of 20 to<br />
30mm.<br />
240 120<br />
N/A 6mm CP606 120 60<br />
N/A<br />
N/A<br />
30mm 10mm CP606 130mm<br />
Mineral wool<br />
96kg/m²<br />
50mm<br />
Up to 15<br />
20 to<br />
30<br />
10mm CP606<br />
& 2 x 25mm Ø<br />
PE backing rod<br />
70mm of<br />
Rockfibre<br />
140kg/m 3<br />
density<br />
70mm of<br />
Rockfibre<br />
140kg/m 3<br />
density<br />
10mm of<br />
CP606 for<br />
gaps of<br />
15mm.<br />
15mm of<br />
CP606 for<br />
gaps of 20 to<br />
30mm.<br />
10mm CP606<br />
& 25mm Ø PE<br />
backing rod<br />
240 120<br />
240 90<br />
10mm CP606 240 90<br />
N/A N/A 30 0<br />
N/A<br />
N/A<br />
10mm<br />
CP606<br />
15mm<br />
CP606<br />
240 240<br />
240 210<br />
Cert.<br />
No.<br />
92 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
75mm<br />
steel/steel or<br />
AC/steel floor<br />
75mm<br />
steel/steel or<br />
AC/steel floor<br />
150mm<br />
AC/AC floor<br />
100mm<br />
plasterboard<br />
<strong>part</strong>ition wall<br />
head to<br />
corrugated<br />
metal<br />
decking<br />
100mm<br />
plasterboard<br />
<strong>part</strong>ition wall<br />
head to<br />
corrugated<br />
metal<br />
decking<br />
100mm<br />
plasterboard<br />
<strong>part</strong>ition wall<br />
head to<br />
AC block<br />
100mm<br />
plasterboard<br />
<strong>part</strong>ition wall<br />
head to<br />
AC block<br />
65mm AC<br />
wall with<br />
cement<br />
board facings<br />
and<br />
galvanised<br />
steel<br />
top channel<br />
Steel framed<br />
doorset in<br />
steel or AC<br />
supporting<br />
wall<br />
Timber<br />
framed<br />
doorset<br />
in timber or<br />
concrete<br />
supporting<br />
wall<br />
Timber<br />
framed<br />
doorset<br />
in timber or<br />
concrete<br />
supporting<br />
wall<br />
Gap Size<br />
(mm)<br />
Configuration:<br />
fire side<br />
Up to 15 70mm of<br />
Rockfibre<br />
140kg/m 3<br />
density<br />
20 to 30 70mm of<br />
Rockfibre<br />
140kg/m 3<br />
density<br />
6 to 15 144mm of<br />
Rockfibre<br />
100kg/m3<br />
density<br />
Dependant 10mm CP606<br />
on decking<br />
profile<br />
Dependant<br />
on decking<br />
profile<br />
5mm CP606<br />
10 10mm CP606<br />
& 15mm of<br />
Rockfibre<br />
100kg/m 3<br />
density<br />
5 5mm CP606<br />
& 20mm of<br />
Rockfibre<br />
100kg/m 3<br />
density<br />
Configuration:<br />
middle<br />
N/A<br />
N/A<br />
N/A<br />
80mm of<br />
Rockfibre<br />
100kg/m 3<br />
density<br />
90mm of<br />
Rockfibre<br />
100kg/m 3<br />
density<br />
N/A<br />
N/A<br />
Configuration:<br />
non-fire side<br />
10mm<br />
CP606<br />
15mm<br />
CP606<br />
6mm<br />
CP606<br />
10mm<br />
CP606<br />
5mm<br />
CP606<br />
10mm<br />
CP606 &<br />
15mm of<br />
Rockfibre<br />
100kg/m 3<br />
density<br />
5mm CP606<br />
& 20mm of<br />
Rockfibre<br />
100kg/m 3<br />
density<br />
Use<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
240 0<br />
240 30<br />
240 240<br />
120 120<br />
120 120<br />
120 120<br />
120 120<br />
6 to 15 6mm CP606 N/A N/A 120 120<br />
30 Minimum<br />
70mm<br />
Rockfibre<br />
140kg/m 3<br />
density<br />
N/A<br />
Up to 6 6mm CP606 Minimum<br />
78mm<br />
Rockfibre<br />
140kg/m 3<br />
density<br />
6 to 30 15mm CP606 Minimum<br />
65mm<br />
Rockfibre<br />
140kg/m 3<br />
density<br />
15mm<br />
CP606<br />
6mm<br />
CP606<br />
15mm<br />
CP606<br />
240 0<br />
120 0<br />
120 0<br />
Cert.<br />
No.<br />
20 Nov 2011 93
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Hardwood<br />
timber<br />
framed<br />
doorset with<br />
or without<br />
Architraves<br />
in concrete<br />
or masonry<br />
wall<br />
construction<br />
670kg/m³<br />
minimum<br />
density (1)<br />
Hardwood<br />
timber<br />
framed<br />
doorset with<br />
or without<br />
Architraves<br />
in concrete<br />
or masonry<br />
wall<br />
construction<br />
670kg/m³<br />
minimum<br />
density (1)<br />
Hardwood<br />
timber<br />
framed<br />
doorset with<br />
or without<br />
Architraves<br />
in concrete<br />
or masonry<br />
wall<br />
construction<br />
670kg/m³<br />
minimum<br />
density (1)<br />
Hardwood<br />
timber<br />
framed<br />
doorset with<br />
or without<br />
Architraves<br />
in concrete<br />
or masonry<br />
wall<br />
construction<br />
670kg/m³<br />
minimum<br />
density (1)<br />
Gap Size<br />
(mm)<br />
Up to<br />
10mm<br />
10 to<br />
18mm<br />
18 to<br />
30mm<br />
Up to<br />
30mm<br />
Configuration:<br />
fire side<br />
5mm CP606 &<br />
(optional) Ø<br />
PE backing rod<br />
5mm CP606 &<br />
Ø PE backing<br />
rod<br />
10mm CP606<br />
& Ø PE<br />
backing rod<br />
10mm CP606<br />
Configuration:<br />
middle<br />
N/A<br />
N/A<br />
N/A<br />
Minimum<br />
180mm tightly<br />
packed stone<br />
mineral fibre<br />
Configuration:<br />
non-fire side<br />
5mm CP606 &<br />
(optional) Ø PE<br />
backing rod<br />
5mm CP606 &<br />
Ø PE backing<br />
rod<br />
10mm CP606<br />
& Ø PE<br />
backing rod<br />
Use<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
120 0<br />
90 0<br />
90 0<br />
10mm CP606 120 0<br />
Cert.<br />
No.<br />
Notes:<br />
1. For FD30 Doorsets the following frame materials are applicable Softwood, Hardwood & Mineral composite having minimum density’s<br />
of 450kg/m² or MDF having a minimum density of 750kg/m³. For FD60 & FD90 Doorsets the following frame materials are applicable<br />
Hardwood & Mineral composite having a density of 620kg/m³.<br />
2. AC - Aerated Concrete.<br />
3. Please refer to Hilti installation instructions for further detail<br />
Certificate No: 090a(9) to LPS1132: Issue 4<br />
94 20 Nov 2011
CP 657 Blocks With CP611A Sealant - LBCB Ref. No. 090a(9)<br />
Product<br />
Use<br />
Name<br />
CP 657<br />
blocks with<br />
CP611A<br />
sealant<br />
Element of<br />
construction<br />
orientation<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Element of<br />
construction<br />
material<br />
Wall 200 Concrete or<br />
masonry<br />
Wall 200 Concrete or<br />
masonry<br />
Wall 200 Concrete or<br />
masonry<br />
Wall 200 Concrete or<br />
masonry<br />
Wall 200 Concrete or<br />
masonry<br />
Wall 200 Concrete or<br />
masonry<br />
Wall 200 Concrete or<br />
masonry<br />
Wall 200 Concrete or<br />
masonry<br />
Wall 200 Concrete or<br />
masonry<br />
Wall 200 Concrete or<br />
masonry<br />
60.3 mm diameter x<br />
2.9 mm wall thickness<br />
steel pipe penetration<br />
Floor 200 Concrete 50 mm diameter x 3<br />
mm wall thickness PVC<br />
pipe<br />
Floor 200 Concrete 60.3 mm diameter x<br />
2.9 mm wall thickness<br />
steel pipe penetration<br />
Floor 200 Concrete 50 mm diameter x 5<br />
mm wall thickness<br />
polyethylene pipe<br />
Floor 200 Concrete 110 mm wide cable<br />
tray supporting 3 off<br />
3x50 mm 2 PVC/copper<br />
cables<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
(E)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
(I)<br />
Cert.<br />
No.<br />
180 120 090a/08<br />
22 mm diameter<br />
copper pipe<br />
180 120<br />
28.9 mm diameter x 180 180<br />
2.6mm wall thickness<br />
stainless steel pipe<br />
168.3 mm diameter x 180 90<br />
4.5 mm wall thickness<br />
steel pipe with<br />
Autopack 25 mm thick<br />
Rockwool and PVC<br />
applied insulation<br />
50 mm diameter x 3 180 180<br />
mm wall thickness PVC<br />
pipe<br />
50 mm diameter x 5 180 180<br />
mm wall thickness<br />
polyethylene pipe<br />
316 mm wide cable 180 180<br />
tray supporting 15 off<br />
3x4 mm 2 PVC/copper<br />
cables<br />
110 mm wide cable 180 90<br />
tray supporting 3 off<br />
3x50 mm 2 PVC/copper<br />
cables<br />
Cable bundle 40 180 180<br />
cables 2x1.5mm 2<br />
316 mm wide cable 180 120<br />
20x2x0.6mm 2<br />
tray supporting 3 off<br />
bundles of 10 cables<br />
180 180<br />
180 120<br />
180 180<br />
180 120<br />
180 180<br />
Floor 200 Concrete 316 mm wide cable<br />
mm 2<br />
tray supporting 30 off<br />
PVC/copper cables, 15<br />
3x4 mm 2 , 15 4x2.5<br />
Note:<br />
For CP657 Blocks with CP611A sealant:<br />
The CP 657 blocks shall be compress fitted into the aperture with blocks cut, where required, to fit around the services and aperture. CP<br />
611A sealant shall be applied on blocks in direct contact with the aperture and for the full depth of the aperture (200mm) around each<br />
penetration element of a thickness nominally 5mm (15mm around pipes). Cable bundles shall be completely filled with CP 611A sealant.<br />
See manufacturer's installation/application instruction for full details.<br />
Certificate No: 090a(7) to LPS1132: Issue 4<br />
20 Nov 2011 95
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
CP 672/CFS-SP WB Linear Gap Seals - LPCB Ref No: 090a(7)<br />
Product<br />
Name<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with<br />
Rockwool<br />
RP-V<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with<br />
Rockwool<br />
Termarock 40<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with<br />
Rockwool<br />
RP-V<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with<br />
Rockwool<br />
Termarock 40<br />
Element of<br />
construction<br />
Orientation<br />
Vertical joint<br />
in Wall<br />
Vertical joint<br />
in Wall<br />
Element of<br />
construction<br />
Thickness/<br />
Depth<br />
(mm)<br />
150<br />
(minimum)<br />
150<br />
(minimum)<br />
Floor 150<br />
(minimum)<br />
Floor 150<br />
(minimum)<br />
Element of<br />
construction<br />
Material<br />
Aerated<br />
Concrete,<br />
blockwork or<br />
masonry.<br />
Minimum<br />
density<br />
380kg/m³<br />
Aerated<br />
Concrete, or<br />
masonry.<br />
Minimum<br />
density<br />
380kg/m³<br />
Concrete and<br />
blockwork.<br />
Minimum<br />
density<br />
2400kg/m³<br />
Concrete and<br />
blockwork.<br />
Minimum<br />
density<br />
2400kgm³<br />
Application<br />
Maximum joint width 100 mm,<br />
minimum installation depth 150mm.<br />
Joint 50% compression filled with<br />
50mm thick layers of Rockwool RP-<br />
V mineral fibre panels of nominal<br />
38.5kg/m3 density compress fitted<br />
trimmed flush with both the inner<br />
and outer surface of the joint. Both<br />
surfaces spray coated with CP<br />
672/CFS-SP WB nominally 3-5mm<br />
thick extending beyond the edge of<br />
the joint onto surface of<br />
surrounding construction by a<br />
minimum of 15mm each side. 25%<br />
lateral expansion applied during<br />
test.<br />
Maximum joint width 100 mm,<br />
minimum installation depth 150mm.<br />
Joint 50% compression filled with<br />
50mm thick layers of Rockwool<br />
Termarock 40 mineral fibre panels<br />
of nominal 42.6kg/m 3 density<br />
compress fitted trimmed flush with<br />
both the inner and outer surface of<br />
the joint. Both surfaces spray<br />
coated with CP 672/CFS-SP WB<br />
nominally 3-5mm thick extending<br />
beyond the edge of the joint onto<br />
surface of surrounding construction<br />
by a minimum of 15mm each side.<br />
0-40% lateral expansion applied<br />
during tests.<br />
Maximum joint width 100 mm,<br />
minimum installation depth 100mm.<br />
Joint 50% compression filled with<br />
50mm thick layers of Rockwool RP-<br />
V mineral fibre panels of nominal<br />
38.5kg/m 3 density compress fitted<br />
trimmed flush with the upper (nonfire)<br />
surface of the joint. The upper<br />
surface spray coated with CP<br />
672/CFS-SP WB nominally 3-5mm<br />
thick extending beyond the edge of<br />
the joint onto surface of<br />
surrounding construction by a<br />
minimum of 15mm each side. 0-<br />
25% lateral expansion applied<br />
during test.<br />
Maximum joint width 100 mm,<br />
minimum installation depth 100mm.<br />
Joint 50% compression filled with<br />
50mm thick layers of Rockwool<br />
Termarock 40 mineral fibre panels<br />
of nominal 42.6kg/m 3 density<br />
compress fitted trimmed flush with<br />
the upper (non-fire) surface of the<br />
joint. The upper surface spray<br />
coated with CP 672/CFS-SP WB<br />
nominally 3-5mm thick extending<br />
beyond the edge of the joint onto<br />
surface of surrounding construction<br />
by a minimum of 15mm each side.<br />
40% lateral expansion applied<br />
during test.<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity/<br />
Insulation<br />
(EN 1366-<br />
4)<br />
Cert.<br />
No.<br />
240/240 090a/05<br />
240/240<br />
240/120<br />
240/120<br />
96 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Certificate No: 090a(7) to LPS1132: Issue 4<br />
CP 672/CFS-SP WB Linear Gap Seals - LPCB Ref No: 090a(7)<br />
Product<br />
Name<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with<br />
64kg/m³<br />
density<br />
mineral fibre<br />
batt<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with<br />
32kg/m³<br />
density<br />
mineral fibre<br />
batt<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with CP<br />
777 plugs<br />
and CP 757<br />
strips<br />
Element of<br />
construction<br />
Orientation<br />
Element of<br />
construction<br />
Thickness<br />
/Depth<br />
(mm)<br />
Element of<br />
construction<br />
Material<br />
Floor 115 Lightweight<br />
concrete floor<br />
slab<br />
Floor 115 Lightweight<br />
concrete floor<br />
slab<br />
Wall head to<br />
concrete topped<br />
metal deck<br />
assembly<br />
Wall thickness<br />
100 Floor<br />
assembly 140<br />
Note 1<br />
Application<br />
Maximum joint width 75mm,<br />
minimum installation depth<br />
115mm. Joint filled with 4<br />
layers of 108mm wide x 38mm<br />
thick layers of mineral fibre batt<br />
of nominal 64kg/m 3 density<br />
50% compress fitted flush with<br />
the lower (fire side) surface of<br />
the joint. The upper surface<br />
spray coated with CP<br />
672/CFS-SP WB nominally<br />
6mm thick flush with the upper<br />
(non-fire) surface and<br />
extending beyond the edge of<br />
the joint onto surface of<br />
surrounding construction by a<br />
minimum of 20mm each side<br />
Maximum joint width 90mm,<br />
minimum installation depth<br />
115mm. Joint filled with 4<br />
layers of 112mm wide x 38mm<br />
thick layers of mineral fibre batt<br />
of nominal 32kg/m 3 density<br />
42% compress fitted flush with<br />
the lower (fire side) surface of<br />
the joint. The upper surface<br />
spray coated with CP<br />
672/CFS-SP WB nominally<br />
3mm thick flush with the upper<br />
(non-fire) surface and<br />
extending beyond the edge of<br />
the joint onto surface of<br />
surrounding construction by a<br />
minimum of 12mm each side<br />
Minimum 25mm gap between<br />
wall head and metal deck<br />
increasing to 100 mm into deck<br />
profile. CP 777 plugs friction<br />
fitted to completely fill deck<br />
profile cavities flush with both<br />
sides of<br />
wall. CP 767 strips<br />
compressed 50% and inserted<br />
into remaining joint gaps flush<br />
with both sides of wall.<br />
Complete outer surface of joint<br />
coated with CP 672/CFS-SP<br />
WB nominally 3 mm thick<br />
extending beyond the<br />
perimeter of the seal onto<br />
surface of surrounding gypsum<br />
wall and decking by 13mm on<br />
both sides of wall assembly.<br />
Fire<br />
Resistance<br />
(mm)<br />
Integrity/<br />
Insulation<br />
(BS 476:<br />
Part 20)<br />
Cert.<br />
No.<br />
240/120 090a/05<br />
180/120<br />
120/120<br />
20 Nov 2011 97
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with 64<br />
kg/m³ mineral<br />
wool<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with<br />
40kg/m³<br />
Mineral wool<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with 64<br />
kg/m³ mineral<br />
wool<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with<br />
64kg/m³<br />
mineral wool<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with 32<br />
kg/m³ mineral<br />
wool<br />
Element of<br />
construction<br />
Orientation<br />
Wall head to<br />
concrete topped<br />
metal deck<br />
assembly<br />
Floor / Curtain wall<br />
system<br />
Partition wall head<br />
to floor soffit<br />
Concrete/Masonry<br />
wall head to floor<br />
soffit<br />
Partition wall head<br />
to composite floor<br />
Element of<br />
construction<br />
Thickness<br />
/Depth<br />
(mm)<br />
Wall thickness<br />
200 Floor<br />
assembly 140<br />
Floor<br />
thickness 200<br />
Element of<br />
construction<br />
Material<br />
Note 2<br />
Floor<br />
Reinforced<br />
Concrete.<br />
Mminimum<br />
density<br />
2200kg/m³<br />
Application<br />
Minimum 90 mm gap between<br />
wall head and metal deck<br />
increasing to 165 mm into deck<br />
profile. Mineral wool of 64<br />
kg/m 3 density 50% compress<br />
packed into flutes/joint flush<br />
with both sides of wall.<br />
Complete outer surface of joint<br />
coated with CP 672/CFS-SP<br />
WB nominally 3 mm thick<br />
extending beyond the<br />
perimeter of the seal onto<br />
surface of surrounding gypsum<br />
wall and decking by<br />
13mm on both sides of wall<br />
assembly.<br />
Maximum gap between<br />
supporting floor and the façade<br />
(Curtain wall system) 210mm.<br />
The Horizontal Linear gap seal<br />
(perimeter seal) system<br />
comprised of 7 layers of<br />
mineral wool board (RPV -40<br />
Rockwool) 200mm wide 60mm<br />
thick compressed to 50% and<br />
with a density of 40kg/m³.<br />
Mineral wool coated on the<br />
upper surface (non-fire side)<br />
with dry film thickness of 1.5-<br />
2.0mm of CP 672/CFS-SP WB<br />
fire stop joint spray.<br />
Note 3 Note 3 Minimum 25mm gap between<br />
wall head and floor soffit. Joint<br />
seal comprising of Mineral wool<br />
64 kg/m³ with 50%<br />
compression filled to the full<br />
depth of the wall and coated<br />
with CP 672/CFS-SP WB Fire<br />
stop joint spray<br />
Note 4 Note 4 Minimum 25mm gap between<br />
wall head and floor soffit. Joint<br />
seal comprising of Mineral wool<br />
64 kg/m³ with 50%<br />
compression filled to the full<br />
depth of the wall and coated<br />
with CP 672/CFS-SP WB Fire<br />
stop joint spray.<br />
Note 5 Note 5 Maximum 50mm gap between<br />
the top of the wall <strong>part</strong>ition<br />
boards and the valleys of the<br />
steel floor construction. Joint<br />
seal comprising of Mineral wool<br />
32 kg/m³ with 50%<br />
compression fitted between the<br />
wall board edges and the<br />
underside of the steel floor<br />
construction either side of the<br />
wall coated with a 3mm wet<br />
thickness coating of CP<br />
672/CFS-SP WB Fire stop joint<br />
spray overlapping the spray<br />
applied steel protection<br />
material by 50mm and by<br />
12mm over the wall boards.<br />
Fire<br />
Resistance<br />
(mm)<br />
Integrity/<br />
Insulation<br />
(BS 476:<br />
Part 20)<br />
120/120<br />
120/120<br />
240/240<br />
240/240<br />
120/120<br />
Cert.<br />
No.<br />
98 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
CP<br />
672Y/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with 32<br />
kg/m³ mineral<br />
wool<br />
CP 672/CFS-<br />
SP WB Fire<br />
stop joint<br />
spray with<br />
32kg/m³<br />
mineral wool<br />
Element of<br />
construction<br />
Orientation<br />
Partition wall head<br />
to composite floor<br />
Partition wall head<br />
to composite floor<br />
Element of<br />
construction<br />
Thickness<br />
/Depth<br />
(mm)<br />
Element of<br />
construction<br />
Material<br />
Application<br />
Note 6 Note 6 Maximum 100mm aperture<br />
around the lattice beam. Joint<br />
seal comprising of Mineral wool<br />
32 kg/m³ with 50%<br />
compression fitted into the<br />
aperture around the lattice<br />
beam and coated with a 3mm<br />
wet thickness coating of CP<br />
672/CFS-SP WB Fire stop joint<br />
spray to all exposed mineral<br />
wool overlapping the spray<br />
applied steel protection<br />
material by 50mm and by<br />
12mm over the wall boards.<br />
Note 7 Note 7 Maximum 25mm gap between<br />
the top of the wall <strong>part</strong>ition<br />
boards and the valleys of the<br />
steel floor construction. Joint<br />
seal comprising of layers of<br />
Mineral wool 32 kg/m³ cut to<br />
the shape of the fluted floor<br />
units approximately 20% larger<br />
than the widths of the flutes<br />
and compression fitted into the<br />
flutes of the floor units above<br />
the ceiling channel, additional<br />
50mm x 30mm <strong>section</strong>s of<br />
mineral wool shall be 50%<br />
compression fitted between the<br />
top of the wall boards and the<br />
underside of the steel floor<br />
units either side of the wall and<br />
coated with a 3mm wet<br />
thickness coating of<br />
CP 672Y/CFS-SP WB Fire<br />
stop joint spray to exposed<br />
mineral wool and overlapping<br />
the wall boards by 12mm.<br />
Fire<br />
Resistance<br />
(mm)<br />
Integrity/<br />
Insulation<br />
(BS 476:<br />
Part 20)<br />
120/120<br />
120/120<br />
Cert.<br />
No.<br />
Notes:<br />
1 2 hour fire rated Wall 64 mm steel stud faced on each side with 2 x 15 mm layers Type ‘X’ gypsum board and Profiled metal deck<br />
assembly topped with 64 mm concrete.<br />
2. Concrete block wall and Profiled metal deck assembly topped with 64 mm concrete.<br />
3. Applicable to UL Joint system No’s. HW-D-0292 & HW-D-0295. The specification of the gypsum board based drywall and composite<br />
steel/concrete profiled deck supporting constructions shall provide the required fire resistance of 240 minutes.<br />
4. Applicable to UL Joint system No’s HW-D-0294 & HW-D-0296. The specification of the concrete/masonry wall and composite<br />
steel/concrete profiled deck supporting constructions shall provide the required fire resistance of 240 minutes.<br />
5. Applicable to UL Joint system No’s. HW-D-0190. The specification of the gypsum board based drywall and composite steel/concrete<br />
profiled deck supporting constructions shall provide the required fire resistance of 120 minutes.<br />
6. Applicable to UL Joint system No’s. HW-D-0218. The specification of the gypsum board based drywall and composite steel/concrete<br />
profiled deck supporting constructions shall provide the required fire resistance of 120 minutes.<br />
7. Applicable to UL Joint system No’s. HW-D-0042 & HW-D-0049. The specification of the gypsum board based drywall and composite<br />
steel/concrete profiled deck supporting constructions shall provide the required fire resistance of 120 minutes.<br />
Certificate No: 090a(10) to LPS1132: Isuue 4<br />
20 Nov 2011 99
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
CP 660 Wall System - LPCB Ref No.: 090a(10)<br />
Product<br />
Name<br />
CP 660<br />
Element of<br />
construction<br />
orientation<br />
Wall<br />
(system H)<br />
Wall<br />
(system A)<br />
Wall<br />
(system B)<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
Penetration<br />
Type<br />
Penetration<br />
Type<br />
120 Drywall Blank seal<br />
without service<br />
penetrations<br />
120 Drywall Perforated<br />
300mm wide<br />
1.5mm thick<br />
mild steel<br />
cable tray (1)<br />
with 1x50mm<br />
dia. Copper<br />
core electric<br />
Cable,<br />
1x32mm dia.<br />
Copper core<br />
Electric Cable,<br />
3x16mm dia.<br />
Mild steel<br />
pipes with<br />
1.5mm wall<br />
thickness and<br />
3x16mm dia.<br />
Plastic pipes<br />
with 1.0mm<br />
wall thickness<br />
and Perforated<br />
300mm wide<br />
1.5mm thick<br />
mild steel<br />
cable tray (1)<br />
with 2x50mm<br />
dia. Aluminium<br />
core Electric<br />
Cables and<br />
1x70mm dia.<br />
Copper core<br />
Electric cable.<br />
120 Drywall Perforated<br />
300mm wide<br />
1.5mm thick<br />
mild steel<br />
cable tray (1)<br />
with 15x13mm<br />
dia. Copper<br />
core Electric<br />
Cables in 2<br />
layers and<br />
30x12mm<br />
communication<br />
cables in<br />
bundle. and<br />
Perforated<br />
300mm wide<br />
1.5mm thick<br />
mild steel<br />
cable tray (1)<br />
with 15x12mm<br />
dia. Copper<br />
core Electric<br />
Cables in 2<br />
layers<br />
Penetration/seal<br />
Size<br />
(mm)<br />
400 x 400 x 120<br />
thick<br />
400 x 400 x 120<br />
thick<br />
400 x 400 x 120<br />
thick<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
Cert.<br />
No.<br />
120 120 090a/09<br />
120 60<br />
120 90<br />
100 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Wall<br />
(system C)<br />
Wall<br />
(system D)<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
Penetration<br />
Type<br />
Penetration<br />
Type<br />
120 Drywall 1x50mm dia.<br />
PVC-u pipe<br />
with 2.4mm<br />
wall thickness<br />
(2) and<br />
1x50mm dia.<br />
PVC-u pipe<br />
with 1.8mm<br />
wall thickness<br />
(2) and<br />
CP643-<br />
50/1.5N pipe<br />
collar on each<br />
side of<br />
penetration<br />
seal (4) and<br />
1x110mm dia.<br />
PVC-u pipe<br />
with 1.8mm<br />
wall thickness<br />
(3) and<br />
CP643-110/4N<br />
pipe collars on<br />
each side of<br />
the penetration<br />
seal (4) and<br />
1x110mm dia.<br />
PVC-u pipe<br />
with 12.3mm<br />
wall thickness<br />
(3) and<br />
CP643-110/4N<br />
pipe collars on<br />
each side of<br />
the penetration<br />
seal (4)<br />
120 Drywall 1x50mm dia.<br />
PVC-u pipe<br />
with 1.8mm<br />
wall thickness<br />
(2) with 1 layer<br />
of CP648-E<br />
pipe wrap (5).<br />
and 1x110mm<br />
dia. PVC-u<br />
pipe with<br />
1.8mm wall<br />
thickness (3)<br />
with 2 layers of<br />
CP648-E pipe<br />
wrap (5). and<br />
1x110mm dia.<br />
PVC-u pipe<br />
with 12.3mm<br />
wall thickness<br />
(3) with 2<br />
layers of<br />
CP648-E pipe<br />
wrap (5).<br />
Penetration/seal<br />
Size<br />
(mm)<br />
400 x 400 x 120<br />
thick<br />
400 x 400 x 120<br />
thick<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
120 120<br />
120 120<br />
Cert.<br />
No.<br />
20 Nov 2011 101
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Wall<br />
(system F)<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
Penetration<br />
Type<br />
Penetration<br />
Type<br />
120 Drywall 1x110mm dia.<br />
PE pipe with<br />
12.5mm wall<br />
thickness (3)<br />
and CP643-<br />
110/4N pipe<br />
collars on each<br />
side of the<br />
penetration<br />
seal (4) and<br />
1x110mm dia.<br />
PE pipe with<br />
2.4mm wall<br />
thickness (3)<br />
and CP643-<br />
110/4N pipe<br />
collars on each<br />
side of the<br />
penetration<br />
seal (4) and<br />
1x50mm dia.<br />
PE pipe (2)<br />
with 4.2mm<br />
wall thickness<br />
and 1x50mm<br />
dia. PE pipe<br />
(2) with 2.4mm<br />
wall thickness<br />
and CP643-<br />
50/1.5N pipe<br />
collars on each<br />
side of the<br />
penetration<br />
seal (4)<br />
Penetration/seal<br />
Size<br />
(mm)<br />
400 x 400 x 120<br />
thick<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
120 120<br />
Cert.<br />
No.<br />
Notes:<br />
Wall system<br />
1. Cable tray fixed to Hilti MQ41/3 unistrut support system, wire cable ties used with cable tray on both sides of the penetration.<br />
2. Pipe fixed to Hilti MQ41/3 unistrut support system using Hilti MPN-S 1.5” pipe clamps.<br />
3. Pipe fixed to Hilti MQ41/3 unistrut support system using Hilti MPN-S 110mm pipe clamps.<br />
5. Pipewrap fixed with ‘Pattex’ self-adhesive tape.<br />
Certificate No: 090a(10) to LPS1132: Issue 4<br />
CP 660 Floor System - LPCB Ref No.: 090a(10)<br />
Product<br />
Name<br />
CP 660<br />
Element of<br />
construction<br />
orientation<br />
Floor<br />
(system A)<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
150<br />
concrete (6)<br />
Element of<br />
construction<br />
material<br />
Aerated<br />
concrete (6)<br />
Penetration<br />
Type<br />
Penetration<br />
Type<br />
Blank seal<br />
without<br />
service<br />
penetrations<br />
Penetration/seal<br />
Size<br />
400 x 400 x 150<br />
thick<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
Cert.<br />
No.<br />
120 90 090a/09<br />
102 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Floor<br />
(system B)<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
150 Aerated<br />
concrete (6)<br />
Penetration<br />
Type<br />
Penetration<br />
Type<br />
Perforated<br />
300mm wide<br />
1.5mm thick<br />
mild steel<br />
cable tray (1)<br />
with 1x50mm<br />
dia. Copper<br />
core Electric<br />
Cable,<br />
1x32mm dia.<br />
Copper core<br />
Electric Cable,<br />
3x16mm dia.<br />
Mild steel<br />
pipes with<br />
1.5mm wall<br />
thickness and<br />
3x16mm dia.<br />
Plastic pipes<br />
with 1.0mm<br />
wall thickness.<br />
and<br />
Perforated<br />
300mm wide<br />
1.5mm thick<br />
mild steel<br />
cable tray (1)<br />
with 2x50mm<br />
dia.<br />
Aluminium<br />
core Electric<br />
Cables and<br />
1x70mm dia.<br />
Copper core<br />
Electric cable.<br />
Penetration/seal<br />
Size<br />
400 x 400 x 150<br />
thick<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
180 90<br />
Cert.<br />
No.<br />
20 Nov 2011 103
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Floor<br />
(system C)<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
150 Aerated<br />
concrete (6)<br />
Penetration<br />
Type<br />
Penetration<br />
Type<br />
1x50mm dia.<br />
PVC-u pipe<br />
with 4.8mm<br />
wall thickness<br />
(2) and<br />
1x50mm dia.<br />
PVC-u pipe<br />
with 1.8mm<br />
wall thickness<br />
(2) and<br />
CP643-<br />
50/1.5N pipe<br />
collar on<br />
exposed side<br />
of penetration<br />
seal (4) and<br />
1x110mm dia.<br />
PVC-u pipe<br />
with 1.8mm<br />
wall thickness<br />
(3) and<br />
CP643-<br />
110/4N pipe<br />
collars on<br />
exposed side<br />
of the<br />
penetration<br />
seal (4) and<br />
1x110mm dia.<br />
PVC-u pipe<br />
with 12.3mm<br />
wall thickness<br />
(3) and<br />
CP643-<br />
110/4N pipe<br />
collars on<br />
exposed side<br />
of the<br />
penetration<br />
seal (4)<br />
Penetration/seal<br />
Size<br />
400 x 400 x 150<br />
thick<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
180 180<br />
Cert.<br />
No.<br />
104 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Floor<br />
(system E)<br />
Floor<br />
(system H)<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
150 Aerated<br />
concrete (6)<br />
150 Aerated<br />
concrete (6)<br />
Penetration<br />
Type<br />
Penetration<br />
Type<br />
1x110mm dia.<br />
PE pipe with<br />
12.5mm wall<br />
thickness (3)<br />
and CP643-<br />
110/4N pipe<br />
collars on<br />
exposed side<br />
of the<br />
penetration<br />
seal (4) and<br />
1x110mm dia.<br />
PE pipe with<br />
2.4mm wall<br />
thickness (3)<br />
and CP643-<br />
110/4N pipe<br />
collars on<br />
exposed side<br />
of the<br />
penetration<br />
seal (4) and<br />
1x50mm dia.<br />
PE pipe with<br />
4.2mm wall<br />
thickness (2)<br />
and 1x50mm<br />
dia. PE pipe<br />
with 2.4mm<br />
wall thickness<br />
(2) and<br />
CP643-<br />
50/1.5N pipe<br />
collars on<br />
exposed side<br />
of the<br />
penetration<br />
seal (4)<br />
1x50mm dia.<br />
PVC-u pipe<br />
with 1.8mm<br />
wall thickness<br />
(2) with 1<br />
layer of<br />
CP648-E pipe<br />
wrap (5).and<br />
1x110mm dia.<br />
PVC-u pipe<br />
with 1.8mm<br />
wall thickness<br />
(3) with 2<br />
layers of<br />
CP648-E pipe<br />
wrap (5). and<br />
1x110mm dia.<br />
PVC-u pipe<br />
with 12.3mm<br />
wall thickness<br />
(3) with 2<br />
layers of<br />
CP648-E pipe<br />
wrap (5).<br />
Penetration/seal<br />
Size<br />
400 x 400 x 150<br />
thick<br />
400 x 400 x 150<br />
thick<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
180 180<br />
180 180<br />
Cert.<br />
No.<br />
20 Nov 2011 105
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
construction<br />
orientation<br />
Floor<br />
(system I)<br />
Element of<br />
construction<br />
thickness<br />
(mm)<br />
Element of<br />
construction<br />
material<br />
150 Aerated<br />
concrete (6)<br />
Penetration<br />
Type<br />
Penetration<br />
Type<br />
1x50mm PE<br />
pipe with<br />
2.4mm wall<br />
thickness (2)<br />
with 1 layer of<br />
CP648-E pipe<br />
wrap (5). and<br />
1x110mm PE<br />
pipe with<br />
2.4mm wall<br />
thickness (3)<br />
with 2 layers<br />
of CP648-E<br />
pipe wrap (5).<br />
and 1x110mm<br />
PE pipe with<br />
12.5mm wall<br />
thickness (3)<br />
with 2 layers<br />
of CP648-E<br />
pipe wrap.(5)<br />
Penetration/seal<br />
Size<br />
400 x 400 x 150<br />
thick<br />
Integrity<br />
(min)<br />
Insulation<br />
(min)<br />
180 180<br />
Cert.<br />
No.<br />
Notes:<br />
Floor system<br />
1. Cable tray fixed to Hilti MQ41/3 unistrut support system, wire cable ties used with cable tray on both sides of the penetration.<br />
2. Pipe fixed to Hilti MQ41/3 unistrut support system using Hilti MPN-S 1.5” pipe clamps.<br />
3. Pipe fixed to Hilti MQ41/3 unistrut support system using Hilti MPN-S 110mm pipe clamps.<br />
4. Fixed to the unexposed face of the penetration seal using M8 threaded rods with hexagonal head steel nuts and washers.<br />
5. Pipewrap fixed with ‘Pattex’ self-adhesive tape.<br />
6. Aerated concrete density 670g/m 3<br />
Certificate No: 090a (11) to LPS 1132: Issue 4<br />
Penetration Gap Seals – CP670 Fire Safety System (Unframed single layer 50mm)<br />
Product<br />
Name<br />
Aperture<br />
Size<br />
Penetration<br />
Type (3)<br />
CP 670<br />
Fire<br />
Safety<br />
System<br />
Elements of<br />
Construction<br />
Orientation<br />
Elements of<br />
Construction<br />
Thickness<br />
min (mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Cables 10mm<br />
(5)(6)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Cert.<br />
No.<br />
90 30 090a/10<br />
Cables 10mm 90 60<br />
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Elements of<br />
Construction<br />
Orientation<br />
Elements of<br />
Construction<br />
Thickness<br />
min (mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Aperture<br />
Size<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 5000<br />
mm wide<br />
x 2400<br />
mm high<br />
(1).<br />
Penetration<br />
Type (3)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Cable Trays 120 60<br />
Mild Steel<br />
Trunking<br />
250mm x<br />
250mm x<br />
1.5mm thick<br />
120 30<br />
Blank Seals 120 60<br />
Steel Pipes<br />
114mm &<br />
250mm Ø x<br />
6.3mm thick<br />
Copper Pipes<br />
108mm Ø x<br />
2mm thick<br />
CP642 Collars<br />
(recessed/surface<br />
mounted) pipes<br />
≤ 160 mm Ø x<br />
5.6mm thick<br />
CP643 Collars<br />
(recessed)<br />
PVC pipes<br />
≤ 110 mm Ø x<br />
4mm thick<br />
120 0<br />
120 0<br />
120 60<br />
120 0<br />
Cert.<br />
No.<br />
Notes:<br />
1. LPCB Ref No 090a/10 CP670 Fire Safety System consists of pre-coated CP670 Fire Safety Board (Rocksilk Universal Slab RS 160 -<br />
180 mineral wool batt maximum 1200m x 600mm wide having a 160-180kg/m3 density utilising cruciform joints at maximum<br />
dimensions of 2400mm x 1200mm wide), coated with CP 670 Fire Safety Coating nominally 0.7mm thick extending beyond the<br />
perimeter of the seal onto surface of surrounding construction by 12.5mm unless otherwise stated.<br />
2. All Gaps around all penetration types are to be sealed with Hilti CP606 (or CP611A where indicated (a)) mastic joint filler.<br />
3. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in<br />
any manner for the stated period<br />
4. CP642 Collars are approved with Polyethylene (PE), Polyvinyl chloride (PVC), Polypropylene (PP), Polybutylene (PB), and<br />
Acrylonitrile butadiene styrene (ABS) pipes only.<br />
5. All cables required to provide 90 to 120 minutes insulation and integrity must include a 150mm coat back of CP670 Fire safety<br />
coating, where 60 minutes integrity and insulation is required the coat back may be reduced to 100mm and no coat back is required<br />
where 30 minutes integrity and insulation is required.<br />
6. Cables may be individual or bunched where they penetrate the CP 670 Fire safety system.<br />
Certificate No: 090a(11) to LPS 1132: Issue 4<br />
20 Nov 2011 107
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Penetration Gap Seals -CP670 Fire Safety System (Framed double layer 100mm) (4) (8)<br />
Product<br />
Name<br />
Aperture<br />
Size<br />
Penetration<br />
Type<br />
CP 670<br />
Fire<br />
Safety<br />
System<br />
(1)<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
min (mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Cables ≤<br />
20mm Ø<br />
Cables 20mm<br />
< Ø ≤ 40mm<br />
Cables 40mm<br />
< Ø ≤ 75mm<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Cert.<br />
No.<br />
180 200 090a/10<br />
180 120<br />
180 120<br />
Cable Trays 180 120<br />
Mild Steel<br />
Trunking<br />
250mm<br />
x 250mm x<br />
1.5mm thick<br />
120 30<br />
Blank Seals 240 180<br />
Steel Pipes ≤<br />
250mm Ø x<br />
6.3mm thick<br />
Copper Pipes<br />
≤ 108mm Ø<br />
x 2mm thick<br />
CP642 Collars<br />
(recessed)<br />
pipes<br />
≤ 160 mm Ø x<br />
5.6mm thick<br />
(5)<br />
240 30<br />
240 0<br />
240 60<br />
108 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
min (mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 130 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Aperture<br />
Size<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Maximum<br />
aperture<br />
size<br />
3000 mm<br />
wide x<br />
5000 mm<br />
high<br />
Penetration<br />
Type<br />
CP642 Collars<br />
(surface<br />
mounted)<br />
CP642 Collars<br />
(independently<br />
supported ≤<br />
250mm Ø) (7)<br />
CP643 Collars<br />
(recessed)<br />
PVC pipes ≤<br />
110 mm Ø<br />
x 4mm thick<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
240 60<br />
90 60<br />
120 0<br />
Cert.<br />
No.<br />
Notes:<br />
1. LPCB Ref No 090a/10 CP670 Fire Safety System consists of pre-coated CP670 Fire Safety Board (Rocksilk Universal Slab RS 160 -<br />
180 mineral wool batt maximum 1200m x 600mm wide having a 160-180kg/m3 density utilising cruciform joints at maximum<br />
dimensions of 2400mm x 1200mm wide), coated with CP 670 Fire Safety Coating nominally 0.7mm thick extending beyond the<br />
perimeter of the seal onto surface of surrounding construction by 12.5mm unless otherwise stated.<br />
2. All Gaps around all penetration types are to be sealed with Hilti CP606 mastic joint filler.<br />
3. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in<br />
any manner for the stated period.<br />
4. CP670 Fire Safety System (Framed Double Layer system) comprises of an internal steel channel <strong>section</strong> framework clad on both<br />
faces with 50mm thick coated CP670 Fire Safety Boards which are retained to the framework via insulation pins and non return<br />
washers.<br />
5. CP642 Collars are approved with Polyethylene (PE), Polyvinyl chloride (PVC), Polypropylene (PP), Polybutylene (PB), and<br />
Acrylonitrile butadiene styrene (ABS) pipes only.<br />
6. 150mm coat back of CP670 Fire Safety Coating required.<br />
7. CP642 Collars Independently supported is available with Polyethylene (PE) and Polyvinyl chloride (PVC) only.<br />
8. The framed assembly shall be provided with 25mm of expansion allowance with an additional 20mm restricted expansion which the<br />
system is proved to be capable of accommodating without any undue effects.<br />
Certificate No: 090a(11) to LPS 1132: Issue 4<br />
Penetration Gap Seals – CP670 Fire Safety System (Unframed double layer 100mm)<br />
Product<br />
Name<br />
Aperture<br />
Size<br />
Penetration<br />
Type<br />
CP 670<br />
Fire<br />
Safety<br />
System<br />
(1)<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
min (mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high (1).<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Cables<br />
10mm<br />
Cables<br />
10mm<br />
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
min (mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Aperture<br />
Size<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Penetration<br />
Type<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
(I)<br />
Cables<br />
20mm<br />
<<br />
Ø≤40mm (5)(6) 120 120<br />
Cables<br />
40mm<br />
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
min (mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Wall 100 LW Concrete/<br />
Masonry/<br />
Plasterboard<br />
<strong>part</strong>ition<br />
Aperture<br />
Size<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Maximum<br />
aperture<br />
size 5000<br />
mm<br />
wide x<br />
2400 mm<br />
high<br />
Penetration<br />
Type<br />
CP642<br />
Collars<br />
(surface<br />
mounted)<br />
pipes ≤ 160<br />
mm Ø<br />
x 5.6mm<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
(I)<br />
thick (4) 120 60<br />
CP643<br />
Collars<br />
(recessed)<br />
PVC pipes ≤<br />
110 mm Ø x<br />
4mm thick<br />
120 0<br />
Cert.<br />
No.<br />
Notes:<br />
1. CP670 Fire Safety System (Unframed Double Layer system) utilises cruciform joints within the CP670 Fire Safety System at<br />
Maximum dimensions of 2400mm high x 1200mm wide. No single batt is to be of greater dimensions than 1200mm high x 600mm<br />
coated with CP 670 Fire Safety Coating nominally 0.7mm thick extending beyond the perimeter of the seal onto surface of<br />
surrounding construction by 12.5mm unless otherwise stated and should have an additional CP670 Fire Safety Coating to batt edges.<br />
2. All Gaps around all penetration types are to be sealed with Hilti CP606 mastic joint filler.<br />
3. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in<br />
any manner for the stated period.<br />
4. CP642 Collars are approved with Polyethylene (PE), Polyvinyl chloride (PVC), Polypropylene (PP), Polybutylene (PB), and<br />
Acrylonitrile butadiene styrene (ABS) pipes only<br />
5. All cables required to provide 90 to 120 minutes insulation and integrity must include a 150mm coat back of CP670 Fire Safety<br />
Coating, where 60 minutes integrity and insulation is required the coat back may be reduced to 100mm and no coat back is required<br />
where 30 minutes integrity and insulation is required.<br />
6. Cables may be individual or bunched where they penetrate the CP 670 Fire Safety System.<br />
Certificate No: 090a(9) to LPS 1132: Issue 4<br />
CP657 Blocks with CP651N mastic (wall application) - LPCB Ref. No. 090a(9)<br />
Product<br />
Name<br />
Aperture<br />
size<br />
Use<br />
CP657<br />
Blocks<br />
with<br />
CP615N<br />
mastic<br />
(1)<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 100 Concrete,<br />
concrete block<br />
or masonry<br />
walls minimum<br />
density 600<br />
kg/m³<br />
Wall 100 Concrete,<br />
concrete block<br />
or masonry<br />
walls minimum<br />
density 600<br />
kg/m³<br />
1000mm<br />
high x<br />
700mm<br />
wide or<br />
700mm<br />
high or<br />
1000mm<br />
wide<br />
1000mm<br />
high x<br />
700mm<br />
wide or<br />
700mm<br />
high or<br />
1000mm<br />
wide<br />
Steel Cable<br />
trays,<br />
ladders,<br />
trunking and<br />
conduit<br />
supporting all<br />
cables with<br />
PVC<br />
insulation<br />
Steel,<br />
Stainless<br />
steel & cast<br />
iron Pipes<br />
max 168mm<br />
Ø x 14.2mm<br />
thick<br />
(100kg/m³<br />
mineral fibre<br />
insulation<br />
600 x 40mm<br />
thick) (2)<br />
Fire<br />
Resistance<br />
(min)<br />
Intergrity<br />
(E)<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
(I)<br />
Cert.<br />
No.<br />
120 120 090a/08<br />
120 120<br />
20 Nov 2011 111
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 100 Concrete,<br />
concrete block<br />
or masonry<br />
walls minimum<br />
density 600<br />
kg/m³<br />
Wall 100 Concrete,<br />
concrete block<br />
or masonry<br />
walls minimum<br />
density 600<br />
kg/m³<br />
Wall 100 Concrete,<br />
concrete block<br />
or masonry<br />
walls minimum<br />
density 600<br />
kg/m³<br />
Wall 100 Concrete,<br />
concrete block<br />
or masonry<br />
walls minimum<br />
density 600<br />
kg/m³<br />
Aperture<br />
size<br />
1000mm<br />
high x<br />
700mm<br />
wide or<br />
700mm<br />
high or<br />
1000mm<br />
wide<br />
1000mm<br />
high x<br />
700mm<br />
wide or<br />
700mm<br />
high or<br />
1000mm<br />
wide<br />
1000mm<br />
high x<br />
700mm<br />
wide or<br />
700mm<br />
high or<br />
1000mm<br />
wide<br />
1000mm<br />
high x<br />
700mm<br />
wide or<br />
700mm<br />
high or<br />
1000mm<br />
wide<br />
Use<br />
Steel,<br />
Stainless<br />
steel & cast<br />
iron Pipes<br />
max 88.9mm<br />
Ø x 14mm<br />
thick (45 -<br />
100kg/m³<br />
Armaflex<br />
AF/SH<br />
synthetic<br />
latex<br />
insulation<br />
800 x 9mm<br />
thick) (2)<br />
Steel,<br />
Stainless<br />
steel & cast<br />
iron Pipes<br />
max 88.9mm<br />
Ø x 14mm<br />
thick (45 -<br />
100kg/m³<br />
Armaflex<br />
AF/SH<br />
synthetic<br />
latex<br />
insulation<br />
800 x 31mm<br />
thick) (2)<br />
Copper pipes<br />
max 88.9mm<br />
Ø x 3mm<br />
thick<br />
(100kg/m³<br />
mineral fibre<br />
insulation<br />
800 x 40mm<br />
thick) (2<br />
Copper pipes<br />
max 54mm<br />
Ø x 3mm<br />
thick (45 -<br />
100kg/m³<br />
Armaflex<br />
AF/SH<br />
synthetic<br />
latex<br />
insulation<br />
800 x 9 –<br />
31mm thick)<br />
(2)<br />
Fire<br />
Resistance<br />
(min)<br />
Intergrity<br />
(E)<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
(I)<br />
120 90<br />
120 120<br />
120 120<br />
120 90<br />
Cert.<br />
No.<br />
Notes<br />
For CP657 Blocks with CP651N mastic (wall application);<br />
1. Hilti CP657 Fire Stop Brick with a minimum thickness of 200mm and a nominal density of 270 ± 30kg/m³. If the minimum thickness of<br />
the concrete/masonry wall is 200mm, then the seal may be fitted directly into the opening in the wall. If the thickness is less than<br />
200mm (minimum 100mm for walls) then the opening may either be lined with calcium silicate board, minimum 200mm wide x 25mm<br />
thick, or the opening increased to at least 200mm by fitting calcium silicate board, minimum 50mm wide x 25mm thick, around the<br />
opening. The board is fastened with steel screws into metal plugs at max 300mm centres. The boards may be fitted to either face of<br />
the wall. The calcium silicate board shall be Promatect H or equivalent.<br />
2. The metal pipes shall be fitted with a mineral wool sleeve that is either continuous through the seal or interrupted and butt up to the<br />
face of the seal on both faces.<br />
3. All services passing through the penetration seal system must be supported on both sides of the seal within 500mm from the face of<br />
the seal so that the weight of the services is not taken by the seal system.<br />
112 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Certificate No: 090a(9) to LPS 1132: Issue 4<br />
CP657 Blocks with CP651N mastic (floor application) - LPCB Ref. No. 090a(9)<br />
Product<br />
Name<br />
Aperture<br />
size<br />
Use<br />
CP657<br />
Blocks<br />
with<br />
CP615N<br />
mastic<br />
(1)<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Floor 150 Concrete<br />
minimum<br />
density<br />
600kg/m³<br />
Floor 150 Concrete<br />
minimum<br />
density<br />
600kg/m³<br />
Floor 150 Concrete<br />
minimum<br />
density<br />
600kg/m³<br />
Floor 150 Concrete<br />
minimum<br />
density<br />
600kg/m³<br />
Floor 150 Concrete<br />
minimum<br />
density<br />
600kg/m³<br />
700mm<br />
wide x<br />
unlimited<br />
700mm<br />
wide x<br />
unlimited<br />
700mm<br />
wide x<br />
unlimited<br />
700mm<br />
wide x<br />
unlimited<br />
700mm<br />
wide x<br />
unlimited<br />
Steel Cable<br />
trays, ladders,<br />
Trunking and<br />
conduit<br />
supporting all<br />
cables, PVC<br />
insulated with<br />
copper<br />
conductors ≤<br />
95mm²<br />
bunched or un<br />
bunched & all<br />
cables with<br />
aluminium<br />
conductors<br />
Steel Cable<br />
trays, ladders,<br />
Trunking and<br />
conduit<br />
supporting<br />
cables with<br />
copper<br />
conductors ≥<br />
95mm² with<br />
PVC insulation<br />
Steel,<br />
Stainless steel<br />
& cast iron<br />
Pipes max<br />
168mm Ø x<br />
14.2mm thick<br />
(100kg/m³<br />
mineral fibre<br />
insulation 600<br />
x 40mm thick)<br />
(2)<br />
Steel,<br />
Stainless steel<br />
& cast iron<br />
Pipes max<br />
88.9mm Ø x<br />
14mm thick<br />
(45 - 100kg/m³<br />
Armaflex<br />
AF/SH<br />
synthetic latex<br />
insulation 800<br />
x 9mm thick)<br />
(2)<br />
Steel,<br />
Stainless steel<br />
& cast iron<br />
Pipes max<br />
88.9mm Ø x<br />
14mm thick<br />
(45 - 100kg/m³<br />
Armaflex<br />
AF/SH<br />
synthetic latex<br />
insulation 800<br />
x 31mm thick)<br />
(2)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
(I)<br />
Cert.<br />
No.<br />
120 120 090a/08<br />
120 90<br />
120 120<br />
120 90<br />
120 120<br />
20 Nov 2011 113
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Floor 150 Concrete<br />
minimum<br />
density<br />
600kg/m³<br />
Floor 150 Concrete<br />
minimum<br />
density<br />
600kg/m³<br />
Floor 150 Concrete<br />
minimum<br />
density<br />
600kg/m³<br />
Floor 150 Concrete<br />
minimum<br />
density<br />
600kg/m³<br />
Aperture<br />
size<br />
700mm<br />
wide x<br />
unlimited<br />
700mm<br />
wide x<br />
unlimited<br />
700mm<br />
wide x<br />
unlimited<br />
700mm<br />
wide x<br />
unlimited<br />
Use<br />
Copper pipes<br />
max 88.9mm<br />
Ø x 3mm thick<br />
(100kg/m³<br />
mineral fibre<br />
insulation 800<br />
x 40mm thick)<br />
(2<br />
Copper pipes<br />
max 54mm Ø<br />
x 3mm thick<br />
(45 - 100kg/m³<br />
Armaflex<br />
AF/SH<br />
synthetic latex<br />
insulation 800<br />
x 9 – 31mm<br />
thick) (2)<br />
uPVC pipes<br />
up to 110mm<br />
Ø x 8.2mm<br />
thick<br />
(1.8mm min<br />
wall thickness<br />
for pipes ≤<br />
50mmØ &<br />
<strong>2.2</strong>mm for<br />
pipes ≤<br />
110mm Ø) (3)<br />
HDPE pipes<br />
up to 110mm<br />
Ø x 10mm<br />
thick (2.7mm<br />
min wall<br />
thickness) (3)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
(I)<br />
120 120<br />
120 90<br />
120 120<br />
120 120<br />
Cert.<br />
No.<br />
Notes<br />
For CP657 Blocks with CP651N mastic (floor application);<br />
1. Hilti CP657 Fire Stop Brick with a minimum thickness of 200mm and a nominal density of 270 ± 30kg/m³. If the minimum thickness of<br />
the concrete floor is 200mm, then the seal may be fitted directly into the opening in the floor. If the thickness is less than 200mm<br />
(minimum 150mm for floors) then the opening may either be lined with calcium silicate board, minimum 200mm wide x 25mm thick, or<br />
the opening increased to at least 200mm by fitting calcium silicate board, minimum 50mm wide x 25mm thick, around the opening.<br />
The board is fastened with steel screws into metal plugs at max 300mm centres. The boards may be fitted to the upper face of a floor.<br />
The calcium silicate board shall be Promatect H or equivalent. When fitted in a <strong>part</strong>ition system, the cavity of the <strong>part</strong>ition is closed<br />
around the opening with stud <strong>section</strong>s on all four sides. The opening is lined with calcium silicate board or a fire rated plaster board<br />
(with glass fibre reinforcement), min 200mm wide x 25mm thick.<br />
2. The metal pipes shall be fitted with a mineral wool sleeve that is either continuous through the seal or may be interrupted and butt up<br />
to the face of the seal on both faces.<br />
3. A square or ring of steel mesh must be fitted to the soffit of the penetration seal around the pipe. The mesh is typically1.5mm thick<br />
with a mesh size of 9mm x 9mm. the width of the mesh is at least 50mm on all sides of the pipe. The mesh is fastened to the CP657<br />
bricks with four steel self tapping screws, nominally M6 x 150mm long, equally spaced around the pipe.<br />
4. All services passing through the penetration seal system must be supported on both sides of the seal within 500mm from the face of<br />
the seal so that the weight of the services is not taken by the seal system.<br />
Certificate No: 090a(11) to LPS 1132: Issue 4<br />
114 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Penetration Gap seals - CP670 Fire Safety System (unframed double layer 100mm)<br />
Product<br />
Name<br />
Aperture<br />
Size<br />
Penetration<br />
Type<br />
CP 670<br />
Fire<br />
Safety<br />
System<br />
(1)<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Floor 150 LW Concrete<br />
650kg/m³<br />
Floor 150 LW Concrete<br />
650kg/m³<br />
Floor 150 LW Concrete<br />
650kg/m³<br />
Floor 150 LW Concrete<br />
650kg/m³<br />
Floor 150 LW Concrete<br />
650kg/m³<br />
Floor 150 LW Concrete<br />
650kg/m³<br />
Floor 150 LW Concrete<br />
650kg/m³<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm long<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm long<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm long<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm long<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm long<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm long<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm long<br />
(1).<br />
Fire<br />
Resistance<br />
Integrity<br />
(E)<br />
Fire<br />
Resisitance<br />
Insulation<br />
(I)<br />
Cert.<br />
No.<br />
N/A 120 120 090a/10<br />
Cable Trays<br />
500 x 60 mm<br />
(4)(5)<br />
Cable Trays<br />
300 x 60 mm<br />
(4)(5)<br />
CP644 Collars<br />
(surface<br />
mounted)<br />
pipes 160<br />
mm Ø x 1.8 -<br />
14.6 mm thick<br />
(3)<br />
Steel Pipes<br />
32mm Ø x 2.6<br />
– 4.0 mm<br />
thick<br />
(Insulated with<br />
40 – 50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 500 x<br />
30mm thick)<br />
(6)<br />
Steel Pipes<br />
159 Ø x 4.0 –<br />
14.2 mm thick<br />
or 168.3mm Ø<br />
x 4.0mm thick<br />
(Insulated 40<br />
– 50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 800 x<br />
30mm thick)<br />
(6)<br />
Steel Pipe<br />
168.3mm Ø x<br />
14.2 mm thick<br />
(Insulated with<br />
40 – 50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 1000 x<br />
40mm thick)<br />
(6)<br />
120 120<br />
120 120<br />
120 120<br />
120 120<br />
120 120<br />
120 120<br />
20 Nov 2011 115
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Floor 150 LW Concrete<br />
650kg/m³<br />
Aperture<br />
Size<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm long<br />
(1).<br />
Penetration<br />
Type<br />
Copper Pipe<br />
88.9mm Ø x<br />
1.8 mm thick<br />
(Insulated with<br />
40 – 50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 800 x<br />
40mm thick)<br />
(6)<br />
Fire<br />
Resistance<br />
Integrity<br />
(E)<br />
Fire<br />
Resisitance<br />
Insulation<br />
(I)<br />
120 120<br />
Cert.<br />
No.<br />
Notes:<br />
1. CP670 Fire Safety System consists of 2 x 50mm pre-coated CP670 Fire Safety Board’s having a density of 150kg/m3 & coated with<br />
CP 670 Fire Safety Coating nominally 1.0mm thick extending beyond the perimeter of the seal onto surface of surrounding<br />
construction by 12.5mm unless otherwise stated.<br />
2. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in<br />
any manner for the stated period.<br />
3. CP644 Collars are approved surface mounted to the under side of the floor with High Density Polyethylene (PE - HD) & Polyvinyl<br />
chloride -Un-plasticised (PVC-U) pipes only.<br />
4. All cables & cable trays required to provide 120 minutes insulation and integrity must include a 150mm coat back of CP670 Fire<br />
Safety Coating.<br />
5. Cables may be individual or bunched where they penetrate the CP 670 Fire Safety System.<br />
6. Rockwool Heizungsrohrschale 800 mineral wool insulation (1000mm long x 40mm thick) must be applied from each face of the LW<br />
concrete floor.<br />
Certificate No: 090a(11) to LPS 1132: Issue 4<br />
Penetration Gap Seals - CP670 Fire Safety System (unframed double layer 100mm)<br />
Product<br />
Name<br />
Aperture<br />
Size<br />
Penetration<br />
Type<br />
CP 670<br />
Fire<br />
Safety<br />
System<br />
(1)<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 135 Steel framed<br />
drywall<br />
<strong>part</strong>ition<br />
Wall 135 Steel framed<br />
drywall<br />
<strong>part</strong>ition<br />
Wall 135 Steel framed<br />
drywall<br />
<strong>part</strong>ition<br />
Wall 135 Steel framed<br />
drywall<br />
<strong>part</strong>ition<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm high<br />
(1).<br />
Fire<br />
Resistance<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
Insulation<br />
(I)<br />
Cert.<br />
No.<br />
N/A 120 120 090a/10<br />
Cable Trays<br />
500 x 60 mm<br />
(4)(5)<br />
Cable Trays<br />
300 x 60 mm<br />
(4)(5)<br />
CP644 Collars<br />
(surface<br />
mounted)<br />
pipes 160 mm<br />
Ø x 1.8 -14.6<br />
mm thick (3)<br />
120 120<br />
120 120<br />
120 120<br />
116 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 135 Steel framed<br />
drywall<br />
<strong>part</strong>ition<br />
Wall 135 Steel framed<br />
drywall<br />
<strong>part</strong>ition<br />
Wall 135 Steel framed<br />
drywall<br />
<strong>part</strong>ition<br />
Wall 135 Steel framed<br />
drywall<br />
<strong>part</strong>ition<br />
Aperture<br />
Size<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm high<br />
(1).<br />
Maximum<br />
aperture<br />
size 1000<br />
mm wide<br />
x 2000<br />
mm high<br />
(1).<br />
Penetration<br />
Type<br />
Steel Pipes<br />
32mm Ø x 2.6<br />
– 4.0 mm thick<br />
(Insulated with<br />
40 – 50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 500 x<br />
30mm thick)<br />
(6)<br />
Steel Pipes<br />
159 Ø x 4.0 –<br />
14.2 mm thick<br />
or 168.3mm Ø<br />
x 4.0mm thick<br />
Insulated with<br />
40 – 50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 800 x<br />
30mm thick)<br />
(6)<br />
Steel Pipe<br />
168.3mm Ø x<br />
14.2 mm thick<br />
(Insulated with<br />
40 – 50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 1000 x<br />
40mm thick)<br />
(6)<br />
Copper Pipe<br />
88.9mm Ø x<br />
1.8 mm thick<br />
(Insulated with<br />
40 – 50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 800 x<br />
40mm thick)<br />
(6)<br />
Fire<br />
Resistance<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
Insulation<br />
(I)<br />
120 120<br />
120 120<br />
120 120<br />
120 120<br />
Cert.<br />
No.<br />
Notes:<br />
1. CP670 Fire Safety System consists of 2 x 50mm pre-coated CP670 Fire Safety B|oard’s having a density of 150kg/m3 & coated with<br />
CP 670 Fire Safety Coating nominally 1.0mm thick extending beyond the perimeter of the seal onto surface of surrounding<br />
construction by 12.5mm unless otherwise stated.<br />
2. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in<br />
any manner for the stated period.<br />
3. CP644 Collars are approved surface mounted to the steel framed drywall <strong>part</strong>ition with High Density Polyethylene (PE - HD) &<br />
Polyvinyl chloride -Un-plasticised (PVC-U) pipes only.<br />
4. All cables & cable trays required to provide 120 minutes insulation and integrity must include a 150mm coat back of CP670 Fire<br />
Safety Coating.<br />
5. Cables may be individual or bunched where they penetrate the CP 670 Fire Safety System.<br />
6. Rockwool Heizungsrohrschale 800 mineral wool insulation (1000mm long x 40mm thick) must be applied from each face of the<br />
<strong>part</strong>ition.<br />
Certificate No: 090a(11) to LPS 1132: Issue 4<br />
20 Nov 2011 117
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Penetration Gap Seals - CP670 Fire Safety (unframed single layer 50mm)<br />
Product<br />
Name<br />
Aperture<br />
Size<br />
Penetration<br />
Type<br />
CP 670<br />
Fire<br />
Safety<br />
System<br />
(1)<br />
Elements of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Floor 150 Reinforced<br />
concrete<br />
Floor 150 Reinforced<br />
concrete<br />
Floor 150 Reinforced<br />
concrete<br />
Floor 150 Reinforced<br />
concrete<br />
Floor 150 Reinforced<br />
concrete<br />
Floor 150 Reinforced<br />
concrete<br />
Maximum<br />
aperture<br />
size 2200<br />
mm long x<br />
600 mm<br />
wide (1).<br />
Maximum<br />
aperture<br />
size 2200<br />
mm long x<br />
600 mm<br />
wide (1).<br />
Maximum<br />
aperture<br />
size 2200<br />
mm long x<br />
600 mm<br />
wide (1).<br />
Maximum<br />
aperture<br />
size 2200<br />
mm long x<br />
600 mm<br />
wide (1).<br />
Maximum<br />
aperture<br />
size 2200<br />
mm long x<br />
600 mm<br />
wide (1).<br />
Maximum<br />
aperture<br />
size 2200<br />
mm long x<br />
600 mm<br />
wide (1).<br />
Fire<br />
Resistance<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
Insulation<br />
(I)<br />
Cert.<br />
No.<br />
N/A 60 60 090a/10<br />
Cable trays up<br />
to 500mm<br />
wide by 60mm<br />
deep (4) (5)<br />
Steel Pipes<br />
up to 168mm<br />
Ø x 14.2 mm<br />
thick<br />
(Insulated with<br />
40 – 50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 1000 x<br />
40mm thick)<br />
(6)<br />
Copper Pipes<br />
up to 88.9mm<br />
Ø x 2.5 mm<br />
thick<br />
(Insulated with<br />
40 – 50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 1000 x<br />
40mm thick)<br />
(6)<br />
CP643N<br />
Collars<br />
(surface<br />
mounted)<br />
PVC-U pipes<br />
32 - 110 mm<br />
Ø and up to<br />
8.2 mm wall<br />
thickness (3)<br />
CP643N<br />
Collars<br />
(surface<br />
mounted) PE<br />
pipes 32 - 110<br />
mm Ø and up<br />
to 10 mm wall<br />
thickness (3)<br />
60 60<br />
60 60<br />
60 60<br />
60 60<br />
60 60<br />
Notes:<br />
1. The CP 670 Fire Safety Board System consists of 1 x 50mm pre-coated mineral wool board having a density of 160kg/m³ & coated<br />
with a layer of CP 670 Fire Safety Coating applied to both faces to a thickness of 0.7mm,. The boards were supplied 1200mm long x<br />
600mm wide and were cut to fit. Once in place the boards should be additionally sealed at their edges with CP 606 mastic. Provided<br />
the CP 670 Fire Safety Board System is restricted to 600mm wide its length can be unrestricted.<br />
2. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in<br />
any manner for the stated period.<br />
3. CP643N Collars are approved surface mounted to the under side of the floor with Polyethylene (PE) & Polyvinyl chloride -Unplasticised<br />
(PVC-U) pipes only.<br />
4. All cables & cable trays required to provide 60 minutes insulation and integrity must include a 150mm coat back of CP670 Fire Safety<br />
Coating.<br />
5. Cables (15 - 78mm Ø Copper core 1.5 - 185mm² & 52mm Ø Aluminium core 185mm²) may be individual or bunched where they<br />
penetrate the CP 670 Fire Safety System.<br />
6. Rockwool Heizungsrohrschale 800 mineral wool insulation (1000mm long x 40mm thick) must be applied from each face of the<br />
<strong>part</strong>ition.<br />
118 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Certificate No: 090a(11) to LPS 1132: Issue 4<br />
Penetration Gap Seals - CP670 Fire Safety Systems (unframed double layer 100mm)<br />
Product<br />
Name<br />
Aperture<br />
Size<br />
Penetration<br />
Type<br />
CP 670<br />
Fire<br />
Safety<br />
System<br />
(1)<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Floor 150 Reinforced<br />
concrete<br />
Floor 150 Reinforced<br />
concrete<br />
Floor 150 Reinforced<br />
concrete<br />
Floor 150 Reinforced<br />
concrete<br />
Floor 150 Reinforced<br />
concrete<br />
Floor 150 Reinforced<br />
concrete<br />
Maximum<br />
aperture<br />
size 2100<br />
mm long x<br />
1200 mm<br />
wide (1).<br />
Maximum<br />
aperture<br />
size 2100<br />
mm long x<br />
1200 mm<br />
wide (1).<br />
Maximum<br />
aperture<br />
size 2100<br />
mm long x<br />
1200 mm<br />
wide (1).<br />
Maximum<br />
aperture<br />
size 2100<br />
mm long x<br />
1200 mm<br />
wide (1).<br />
Maximum<br />
aperture<br />
size 2100<br />
mm long x<br />
1200 mm<br />
wide (1).<br />
Maximum<br />
aperture<br />
size 2100<br />
mm long x<br />
1200 mm<br />
wide (1).<br />
Fire<br />
Resisitance<br />
Integrity (E)<br />
Fire<br />
Resisitance<br />
Insulation<br />
(I)<br />
Cert.<br />
No.<br />
N/A 60 60 090a/10<br />
Cable trays<br />
up to 500mm<br />
wide by<br />
60mm deep<br />
(4) (5)<br />
Steel Pipes<br />
up to 168mm<br />
Ø x 14.2 mm<br />
thick<br />
(Insulated<br />
with 40 –<br />
50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 1000 x<br />
40mm thick)<br />
(6)<br />
Copper Pipes<br />
up to 88.9mm<br />
Ø x 2.5 mm<br />
thick<br />
(Insulated<br />
with 40 –<br />
50kg/m²<br />
Rockwool 800<br />
mineral fibre<br />
jacket 1000 x<br />
40mm thick)<br />
(6)<br />
CP643N<br />
Collars<br />
(surface<br />
mounted)<br />
PVC-U pipes<br />
32 - 160 mm<br />
Ø and up to<br />
11.9 mm wall<br />
thickness (3)<br />
CP643N<br />
Collars<br />
(surface<br />
mounted) PE<br />
pipes 32 -<br />
160 mm Ø x<br />
up to 14.6<br />
mm wall<br />
thickness (3)<br />
60 60<br />
60 60<br />
60 60<br />
60 60<br />
60 60<br />
Notes:<br />
1. The CP 670 Fire Safety Board System consists of 2 x 50mm pre-coated mineral wool board having a density of 160kg/m³ & coated<br />
with a layer of CP 670 Fire Safety Coating applied to both faces to a thickness of 0.7mm. The boards were supplied 1200mm long x<br />
600mm wide and were cut to fit. Once in place the boards should be additionally sealed at their edges with CP 606 mastic. Provided<br />
the CP 670 Fire Safety Board System is restricted to 1200mm wide its length can be unrestricted.<br />
2. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in<br />
any manner for the stated period.<br />
3. CP643N Collars are approved surface mounted to the under side of the floor with Polyethylene (PE) & Polyvinyl chloride -Unplasticised<br />
(PVC-U) pipes only.<br />
20 Nov 2011 119
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
4. All cables & cable trays required to provide 60 minutes insulation and integrity must include a 150mm coat back of CP670 Fire Safety<br />
Coating.<br />
5. Cables (15 - 78mm Ø Copper core 1.5 - 185mm² & 52mm Ø Aluminium core 185mm²) may be individual or bunched where they<br />
penetrate the CP 670 Fire Safety System.<br />
6. Rockwool Heizungsrohrschale 800 mineral wool insulation (1000mm long x 40mm thick) must be applied from each face of the floor.<br />
MCT Brattberg AB<br />
SE 37192 Karlskrona, Sweden<br />
Tel: +46 (0) 455 451 60 • Fax: +46 (0) 455 451 28<br />
E-mail: info@mctbrattberg.com • Website: www.mctbrattberg.com<br />
UK Office:<br />
MCT Brattberg Ltd, Commerce Street, Carrs Industrial Estate, Haslingden BB4 5JT, United Kingdom<br />
Tel: +44 (0)1706 244890 • Fax: +44 (0)1706 244891<br />
E-mail: info@mctbrattberg.co.uk • Website: www.mctbrattberg.co.uk<br />
Certificate No: 628a to LPS 1132: Issue 4<br />
Product Name Use Element of<br />
Construction<br />
RGB 2, 4, 6, 8 & RGB 180, 240 & 360 Cables Concrete or masonry<br />
Floor<br />
Steel pipes Concrete or masonry<br />
Floor<br />
Cables Concrete or masonry<br />
Wall<br />
Steel pipes Concrete or masonry<br />
Wall<br />
RGBO 2, 4, 6, 8 & RGBO 180, 240 & 360 Cables Concrete or masonry<br />
Floor<br />
Steel pipes Concrete or masonry<br />
Floor<br />
Cables Concrete or masonry<br />
Wall<br />
Steel pipes Concrete or masonry<br />
Wall<br />
RGP 50, 70, 100, 150, 200 & 300 Cables Concrete or masonry<br />
Floor<br />
Steel pipes Concrete or masonry<br />
Floor<br />
Cables Concrete or masonry<br />
Wall<br />
Steel pipes Concrete or masonry<br />
Wall<br />
RGPO 50, 70, 100, 150, 200 & 300 Cables Concrete or masonry<br />
Floor<br />
Steel pipes Concrete or masonry<br />
Floor<br />
Cables Concrete or masonry<br />
Wall<br />
Steel pipe Concrete or masonry<br />
Wall<br />
Fire Resistance<br />
(min)<br />
Integrity<br />
Fire Resistance<br />
(min)<br />
Insulation<br />
Cert. No.<br />
240 120 628a/01<br />
240 60<br />
240 60<br />
240 60<br />
240 120 628a/02<br />
240 60<br />
240 60<br />
240 60<br />
360 120 628a/03<br />
240 60<br />
360 120<br />
240 60<br />
360 120 628a/04<br />
240 60<br />
360 120<br />
240 60<br />
Note:<br />
Please refer to manufacturer’s product data for maximum aperture sizes and installation details.<br />
120 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Rockwool Limited<br />
Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom<br />
Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302<br />
E-mail: info@rockwool.co.uk • Website: www.rockwool.co.uk<br />
Certificate No: 022b(3) to LPS 1132: Issue 4<br />
Product Name Application Cavity<br />
Width<br />
(mm)<br />
Rockwool Firepro TCB Cavity<br />
Barrier<br />
Masonry/timber<br />
frame and<br />
masonry<br />
cavity walls<br />
Masonry/timber<br />
frame and<br />
masonry<br />
cavity walls<br />
Masonry/timber<br />
frame and<br />
masonry<br />
cavity walls<br />
Masonry/timber<br />
frame and<br />
masonry<br />
cavity walls<br />
Masonry/timber<br />
frame and<br />
masonry<br />
cavity walls<br />
Masonry/timber<br />
frame and<br />
masonry<br />
cavity walls<br />
Masonry/timber<br />
frame and<br />
masonry<br />
cavity walls<br />
Masonry/timber<br />
frame and<br />
masonry<br />
cavity walls<br />
Masonry/timber<br />
frame and<br />
masonry<br />
cavity walls<br />
Masonry/timber<br />
frame and<br />
masonry<br />
Barrier<br />
Size<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resisitance<br />
(min)<br />
Insulation<br />
Cert.<br />
No.<br />
50 - 55 65 X 65 60 30 022b/04<br />
56 - 65 75 x 75 60 30<br />
66 - 75 85 x 85 60 30<br />
76 - 80 90 x 90 60 30<br />
81 - 90 100 x<br />
100<br />
91 - 100 110 x<br />
110<br />
101 -<br />
110<br />
111 -<br />
120<br />
121 -<br />
130<br />
131 -<br />
140<br />
120 x<br />
120<br />
130 x<br />
130<br />
140 x<br />
140<br />
150 x<br />
150<br />
60 30<br />
60 30<br />
60 30<br />
60 30<br />
60 30<br />
60 30<br />
cavity walls<br />
Timber frame 50 - 55 65 x 65 30 30<br />
Timber frame 56 - 65 75 x 75 30 30<br />
Timber frame 66 - 75 85 x 85 30 30<br />
Timber frame 76 - 80 90 x 90 30 30<br />
Timber frame 81 - 90 100 x<br />
30 30<br />
100<br />
Timber frame 91 - 100 110 x<br />
30 30<br />
110<br />
Timber frame 101 - 120 x<br />
30 30<br />
110 120<br />
Timber frame 111 - 130 x<br />
30 30<br />
120 130<br />
Timber frame 121 - 140 x<br />
30 30<br />
130 140<br />
Timber frame 131 - 150 x<br />
30 30<br />
140 150<br />
Timber frame 50 - 55 75 x 75 60 30<br />
Timber frame 56 - 65 75 x 75 60 30<br />
20 Nov 2011 121
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product Name Application Cavity<br />
Width<br />
(mm)<br />
Barrier<br />
Size<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resisitance<br />
(min)<br />
Insulation<br />
Timber frame 66 - 75 85 x 85 60 30<br />
Timber frame 76 - 80 90 x 90 60 30<br />
Timber frame 81 - 90 100 x<br />
60 30<br />
100<br />
Timber frame 91 - 100 110 x<br />
60 30<br />
110<br />
Timber frame 101 - 120 x<br />
60 30<br />
110 120<br />
Timber frame 111 - 130 x<br />
60 30<br />
120 130<br />
Timber frame 121 - 140 x<br />
60 30<br />
130 140<br />
Timber frame 131 - 150 x<br />
60 30<br />
140 150<br />
Timber frame 81 - 90 100 x<br />
60 60<br />
100<br />
Timber frame 91 - 100 110 x<br />
60 60<br />
110<br />
Timber frame 101 - 120 x<br />
60 60<br />
110 120<br />
Timber frame 111 - 130 x<br />
60 60<br />
120 130<br />
Timber frame 121 -<br />
130<br />
140 x<br />
140<br />
60 60<br />
Cert.<br />
No.<br />
Notes:<br />
1. Rockwool Firepro TCB Cavity Barrier is designed for use between the leaves of a masonry cavity wall, timber frame construction, or<br />
between a timber frame inner leaf and masonry outer leaf.<br />
2. Barriers can be installed vertically or horizontally.<br />
3. Refer to manufacturer’s technical literature for fixing details.<br />
Certificate No: 022b(1) to LPS 1132: Issue 4<br />
Product Name<br />
Cavity<br />
Width<br />
(mm)<br />
Slab Size<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Cert. No.<br />
Rockwool Firepro SP 60 Firestop Slab 50 - 400 900 x 650 x 75 60 60 022b/01<br />
Rockwool Firepro SP 120 Firestop Slab 50 - 400 900 x 650 x 90 120 120 022b/02<br />
Notes:<br />
1. This product is suitable for sealing gaps between a concrete or composite concrete/metal floors and an adjacent masonry,<br />
cladding/panel system with non-combustible core or curtain wall, or between the leaves of a masonry cavity wall.<br />
2. For cavity widths of 250mm or more, joints between adjacent lengths of firestops should be sealed on the top surface with aluminium<br />
foil tape.<br />
3. Refer to manufacturer's technical literature for fixing details.<br />
Certificate No: 022b(2) to LPS 1132: Issue 4<br />
Product Name<br />
Rockwool Firepro<br />
Linear and<br />
Trapezoidal<br />
Firestop Systems<br />
Product<br />
Type(s)<br />
Trapezoidal<br />
Firestop 3B<br />
& Linear<br />
Firestop 2<br />
Trapezoidal<br />
Firestop 3B<br />
& Linear<br />
Firestop 2<br />
Wall<br />
Width<br />
(mm)<br />
Firestop<br />
Width<br />
(mm)<br />
Application<br />
100 100 Profiled metal<br />
deck over block<br />
work wall,<br />
with profile<br />
running across<br />
or along the wall<br />
150 150 Profiled metal<br />
deck over block<br />
work wall, with profile<br />
running across<br />
or along the wall<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Cert.<br />
No.<br />
120 120 022b/03<br />
180 180<br />
122 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product Name<br />
Product<br />
Type(s)<br />
Trapezoidal<br />
Firestop 3B<br />
& Linear<br />
Firestop 2<br />
Trapezoidal<br />
Firestop 3B<br />
& Linear<br />
Firestop 2<br />
Trapezoidal<br />
Firestop 3B<br />
& Linear<br />
Firestop 2<br />
Trapezoidal<br />
Firestop 3B<br />
& Linear<br />
Firestop 2<br />
Trapezoidal<br />
Firestop 3B<br />
& Linear<br />
Firestop 2<br />
Trapezoidal<br />
Firestop 3B<br />
& Linear<br />
Firestop 2<br />
Trapezoidal<br />
Firestop 3B<br />
& Linear<br />
Firestop 2<br />
Trapezoidal<br />
Firestop 3B<br />
& Linear<br />
Firestop 2<br />
Trapezoidal<br />
Firestop 3B<br />
Trapezoidal<br />
Firestop 3B<br />
Trapezoidal<br />
Firestop 3B<br />
Wall<br />
Width<br />
(mm)<br />
Firestop<br />
Width<br />
(mm)<br />
Application<br />
200 200 Profiled metal deck<br />
over blockwork<br />
wall, with profile<br />
running across<br />
or along the wall<br />
100 100 Profiled metal deck<br />
with lightweight<br />
concrete over wall,<br />
with profile running<br />
across or along the wall<br />
150 150 Profiled metal<br />
deck with lightweight<br />
concrete over wall,<br />
with profile running<br />
across the wall<br />
150 150 Profiled metal deck<br />
with lightweight concrete<br />
over wall, with profile<br />
running along the wall<br />
200 200 Profiled metal deck<br />
with lightweight concrete<br />
over wall, with profile<br />
running across or<br />
along the wall (1)<br />
100 100 Profiled metal deck<br />
with or without lightweight<br />
concrete over Steel<br />
Universal Beam, with<br />
profile running across the<br />
beam. (1)<br />
150 150 Profiled metal deck<br />
with or without<br />
lightweight concrete<br />
over Steel Universal Beam,<br />
with profile running across<br />
the beam. (1)<br />
200 200 Profiled metal deck<br />
with or without lightweight<br />
concrete over Steel<br />
Universal Beam, with<br />
profile running across the<br />
beam. (1)<br />
N/A 100 Profiled metal deck<br />
with or without lightweight<br />
concrete over Steel<br />
Universal<br />
Beam, with profile<br />
running across the beam.<br />
(1)<br />
N/A 150 Profiled metal deck<br />
with or without lightweight<br />
concrete over Steel<br />
Universal Beam, with<br />
profile running across the<br />
beam. (1)<br />
N/A 200 Profiled metal deck<br />
with or without lightweight<br />
concrete over Steel<br />
Universal<br />
Beam, with profile running<br />
across the beam. (1)<br />
Linear Firestop 2 100 100 Concrete deck over<br />
Blockwork wall<br />
Linear Firestop 2 150 150 Concrete deck over<br />
Blockwork wall<br />
Linear Firestop 2 200 200 Concrete deck over<br />
Blockwork wall<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
240 240<br />
120 120<br />
180 180<br />
240 240<br />
240 240<br />
120 120<br />
180 180<br />
240 240<br />
120 120<br />
180 180<br />
240 240<br />
120 120<br />
180 180<br />
240 240<br />
Cert.<br />
No.<br />
20 Nov 2011 123
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product Name<br />
Product<br />
Type(s)<br />
Trapezoidal<br />
Firestop 3B &<br />
Linear Firestop 2<br />
Trapezoidal<br />
Firestop 3B &<br />
Linear Firestop 2<br />
Trapezoidal<br />
Firestop 3B &<br />
Linear Firestop 2<br />
Linear Firestop<br />
3A<br />
Linear Firestop<br />
3A<br />
Linear Firestop<br />
3A<br />
Linear Firestop<br />
3A<br />
Linear Firestop<br />
3A<br />
Linear Firestop<br />
3A<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Wall<br />
Width<br />
(mm)<br />
Firestop<br />
Width<br />
(mm)<br />
Application<br />
100 100 Profiled concrete deck over<br />
blockwork wall, with profile<br />
running across or along the<br />
wall.<br />
150 150 Profiled concrete deck over<br />
blockwork wall, with profile<br />
running across or along the<br />
wall.<br />
200 200 Profiled concrete deck over<br />
blockwork wall, with profile<br />
running across or along the<br />
wall.<br />
100 300 Concrete deck over<br />
blockwork wall, with<br />
extended firestopping (2)<br />
150 300 Concrete deck over<br />
blockwork wall, with<br />
extended firestopping (2)<br />
200 300 Concrete deck over<br />
blockwork wall, with<br />
extended firestopping (2)<br />
100 400 Concrete deck over<br />
blockwork wall, with<br />
extended firestopping (2)<br />
150 400 Concrete deck over<br />
blockwork wall, with<br />
extended firestopping (2)<br />
200 400 Concrete deck over<br />
blockwork wall, with<br />
extended firestopping (2)<br />
100 200 Profiled Metal deck over<br />
blockwork wall with<br />
extended firestopping, with<br />
profile running across the<br />
wall. (2)<br />
150 200 Profiled Metal deck over<br />
blockwork wall with<br />
extended firestopping, with<br />
profile running across the<br />
wall. (2)<br />
200 200 Profiled Metal deck over<br />
blockwork wall with<br />
extended firestopping, with<br />
profile running across the<br />
wall. (2)<br />
100 300 Profiled Metal deck over<br />
blockwork wall with<br />
extended firestopping, with<br />
profile running across the<br />
wall. (2)<br />
150 300 Profiled Metal deck over<br />
blockwork wall with<br />
extended firestopping, with<br />
profile running across the<br />
wall. (2)<br />
200 300 Profiled Metal deck over<br />
blockwork wall with<br />
extended firestopping, with<br />
profile running across the<br />
wall. (2)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
120 120<br />
240 240<br />
240 240<br />
180 180<br />
240 240<br />
240 240<br />
180 180<br />
240 240<br />
240 240<br />
180 180<br />
180 180<br />
240 240<br />
180 180<br />
240 240<br />
240 240<br />
Cert.<br />
No.<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
100 400 Profiled Metal deck over<br />
blockwork wall with<br />
extended firestopping, with<br />
profile running across the<br />
wall. (2)<br />
180 180<br />
124 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product Name<br />
Product<br />
Type(s)<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Linear Firestop<br />
3A &<br />
Trapezoidal<br />
Firestop 3B<br />
Wall<br />
Width<br />
(mm)<br />
Firestop<br />
Width<br />
(mm)<br />
Application<br />
150 400 Profiled Metal deck over<br />
blockwork wall with<br />
extended firestopping, with<br />
profile running across the<br />
wall. (2)<br />
200 400 Profiled Metal deck over<br />
blockwork wall with<br />
extended firestopping, with<br />
profile running across the<br />
wall. (2)<br />
100 400 Profiled metal deck with<br />
lightweight concrete over<br />
block wall, with the profile<br />
running across the wall. (2)<br />
150 400 Profiled metal deck with<br />
lightweight concrete over<br />
block wall, with the profile<br />
running across the wall. (2)<br />
200 400 Profiled metal deck with<br />
lightweight concrete over<br />
block wall, with the profile<br />
running across the wall. (2)<br />
100 400 Profiled Deck over<br />
blockwork wall with<br />
Asymmetrical profiles, with<br />
the profile running along<br />
the wall. (2)<br />
150 400 Profiled Deck over<br />
blockwork wall with<br />
Asymmetrical profiles, with<br />
the profile running along<br />
the wall. (2)<br />
200 400 Profiled Deck over<br />
blockwork wall with<br />
Asymmetrical profiles, with<br />
the profile running along<br />
the wall. (2)<br />
Linear Firestop 2 100 100 Concrete deck over<br />
blockwork wall<br />
Linear Firestop 2 150 150 Concrete deck over<br />
blockwork wall<br />
Linear Firestop 2 200 200 Concrete deck over<br />
blockwork wall<br />
Trapezoidal 100 100 Profiled metal deck with<br />
Firestop 3B &<br />
lightweight concrete over<br />
Linear Firestop 2<br />
wall, with the profile<br />
Trapezoidal<br />
Firestop 3B &<br />
Linear Firestop 2<br />
Trapezoidal<br />
Firestop 3B &<br />
Linear Firestop 2<br />
running across the wall<br />
150 150 Profiled metal deck with<br />
lightweight concrete over<br />
wall, with the profile<br />
running across the wall<br />
200 200 Profiled metal deck with<br />
lightweight concrete over<br />
wall, with the profile<br />
running across the wall<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
240 240<br />
240 240<br />
180 180<br />
240 240<br />
240 240<br />
180 180<br />
240 240<br />
240 240<br />
120 0<br />
180 0<br />
240 0<br />
120 0<br />
180 0<br />
240 0<br />
Cert.<br />
No.<br />
Notes:<br />
1. The fire resistance of the BeamClad or ColumnClad system used for the fire protection of the beam must be the same as the fire<br />
resistance of the Linear and Trapezoidal Firestop systems. Where the beam has a wall underneath, the gap between the beam<br />
casing and the top of the wall should be packed with linear Firestop 2.<br />
2. Extended firestopping may need to be supported by fire resistant fixings to soffits to avoid edge sag, depending on overhang and<br />
soffit flatness. Supports are essential for extensions greater than 100mm.<br />
3. Where Linear Firestop 2 is used it must be compressed by at least 5% & where Trapezoidal Firestop 3B is used it must be tightly and<br />
accurate fit into trapezoidal profile.<br />
4. Where fire ratings apply to gaps over walls they must be constructed of dense aggregate blocks, lightweight aggregate concrete, clay<br />
bricks, or concrete blocks, which have a density of 400 Kg/m³ or greater.<br />
5. The maximum gap size allowed between the top of the wall and the soffit of the deck/floor is the thickness of the wall.<br />
6. Refer to manufacturer's technical literature for fixing details<br />
20 Nov 2011 125
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Certificate No: 022b(4) to LPS 1132: Issue 4<br />
Product<br />
Name<br />
FirePro <br />
Acoustic<br />
Intumescent<br />
Sealant<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Maximum<br />
Joint<br />
Width<br />
(mm)<br />
Configuration:<br />
Fire Side<br />
Depth of<br />
Sealant<br />
(mm)<br />
Configuration:<br />
Backing<br />
Material<br />
floor 230 AC/AC 50 25 Ethafoam<br />
50mm<br />
floor 230 Softwood/AC 25 12 Ethafoam<br />
0mm<br />
floor 230 Hardwood/AC 50 25 Ethafoam<br />
50mm<br />
floor 230 Steel/AC 50 25 Ethafoam<br />
50mm<br />
floor 250 AC/AC 30 15 Ethafoam<br />
40mm<br />
floor 250 AC/AC 15 10 Ethafoam<br />
mm<br />
floor 250 AC/AC 20 Polyethylene<br />
20mm<br />
floor 250 AC/AC 50 Polyethylene<br />
50 x 25mm<br />
floor 250 AC/AC 10 Polyethylene<br />
0mm<br />
floor 250 AC/AC 25 Polyethylene<br />
25mm<br />
floor 250 Hardwood/AC 15 10 Ethafoam<br />
15mm<br />
floor 250 Steel/AC 15 10 Ethafoam<br />
25mm<br />
wall 150 AC/AC 30 30 Polyethylene<br />
15 x 15<br />
wall 150 AC/AC 15 15 Polyethylene<br />
10 x 10<br />
wall 150 AC/AC 10 10 Polyethylene<br />
10 x 15<br />
wall 150 AC/AC 10 10 Polyethylene<br />
10 x 15<br />
wall 150 AC/AC 15 15 Polyethylene<br />
15 x 15<br />
wall 150 AC/AC 30 30 Polyethylene<br />
30 x 15<br />
wall 200 AC/AC 50 25 Ethafoam<br />
50mm<br />
wall 200 Hardwood/AC 50 25 Ethafoam<br />
50mm<br />
wall 200 Softwood/AC 25 12 Ethafoam<br />
30mm<br />
wall 200 Steel/AC 50 25 Ethafoam<br />
50mm<br />
wall 215 AC/AC 30 15 Ethafoam<br />
40mm<br />
wall 215 AC/AC 15 10 Ethafoam<br />
25mm<br />
wall 215 Hardwood/AC 15 10 Ethafoam<br />
25mm<br />
wall 215 Steel/AC 15 10 Ethafoam<br />
25mm<br />
wall 250 AC/AC 20 Polyethylene<br />
20mm<br />
wall 250 AC/AC 40 Polyethylene<br />
40mm<br />
wall 250 AC/AC 10 Polyethylene<br />
10mm<br />
wall 250 AC/AC 25 Polyethylene<br />
25mm<br />
Configuration:<br />
Non-fire Side<br />
Depth of<br />
Sealant<br />
Configeration:<br />
Non-fire Side<br />
Depth of<br />
Sealant<br />
(mm)<br />
Fire<br />
Resistance<br />
(mm)<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
(mm)<br />
Insulation<br />
(I)<br />
Cert.<br />
No.<br />
155 105 022b/05<br />
51 44<br />
47 47<br />
72 62<br />
243 65<br />
243 29<br />
10 155 47<br />
25 240 92<br />
6 240 207<br />
15 240 73<br />
53 53<br />
243 29<br />
30 265 265<br />
15 265 230<br />
10 265 265<br />
200 166<br />
227 227<br />
240 233<br />
245 82<br />
96 93<br />
55 54<br />
77 39<br />
243 44<br />
243 29<br />
40 29<br />
243 16<br />
10 240 122<br />
20 240 95<br />
10 240 240<br />
20 240 126<br />
Note:<br />
AC - Aerated Concrete.<br />
Ethafoam - Open cell polyethylene foam rod<br />
Please refer to Rockwool installation instructions for further details<br />
Certificate No: 022b(5) to LPS 1132: Issue 4<br />
126 20 Nov 2011
Rockwool FirePro Ablative Coated Batt - Pipe Penetration<br />
Product<br />
Name<br />
Rockwool<br />
FirePro<br />
Ablative<br />
Coated Batt<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Element of<br />
Construction<br />
Material<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Aperture<br />
Size<br />
(mm)<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
Coated Seal Detail<br />
Batt<br />
(layers &<br />
Thickness)<br />
1 x 30mm Rockwool<br />
Insulated<br />
Fire Sleeve<br />
Penetration<br />
Type<br />
ABS<br />
O/D wall<br />
thickness<br />
range<br />
(mm)<br />
27 / 2.5 to<br />
110 / 12<br />
PVC 19 / 1.9 to<br />
1 x 60mm Rockwool<br />
Sleeve (7)<br />
Insulated<br />
Fire<br />
55 / <strong>2.2</strong><br />
PVC >55 / <strong>2.2</strong><br />
1 x 60mm Rockwool<br />
Sleeve (7)<br />
Insulated<br />
Fire<br />
to<br />
110 / 8.9<br />
PVC 110 / <<br />
1 x 60mm Rockwool<br />
Sleeve (7)<br />
Insulated<br />
Fire<br />
3.6<br />
HDPE 110 / 4.2<br />
1 x 60mm Rockwool<br />
Sleeve (7)<br />
Insulated<br />
Fire<br />
to<br />
160 / 6.2<br />
PP >22 / 1.2<br />
1 x 60mm Rockwool<br />
Sleeve (7)<br />
Insulated<br />
Fire<br />
to<br />
160 / 10<br />
Fire<br />
Resistance<br />
Integrity /<br />
Insulation<br />
Cert.<br />
No.<br />
120 / 60 022b/06<br />
90 / 60<br />
60 / 60<br />
120 / 30<br />
90 / 60<br />
60 / 60<br />
PP 22 / 1.2 120 / 120<br />
1 x 60mm Rockwool<br />
Sleeve (7)<br />
Insulated<br />
Fire<br />
1 60mm Unlagged (8) Steel 17.1 / 2.3<br />
to<br />
168.3 / 7.1<br />
1 x 60mm Unlagged (8) Copper 15.0 / 0.7<br />
to<br />
108 / 1.5<br />
1 x 60mm Lagged with<br />
Fire Tube/<br />
Conlit pipe<br />
<strong>section</strong>s<br />
1 x 60mm Lagged<br />
with Fire<br />
Tube/Conlit<br />
pipe<br />
<strong>section</strong>s<br />
1 x 60mm Lagged with<br />
Fire<br />
Tube/Conlit<br />
pipe<br />
<strong>section</strong>s<br />
Steel 88.9 / 4.0<br />
to<br />
164 / 6.4<br />
Copper 15.0 / 0.5<br />
to<br />
108 / 1.5<br />
120 / 0<br />
120 / 0<br />
120 / 60<br />
120 / 60<br />
Copper 50 / 1.8 120 / 120<br />
20 Nov 2011 127
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Product<br />
Name<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 150 Block work<br />
or Concrete<br />
Wall<br />
Wall 150 240min Block<br />
work<br />
or Concrete<br />
wall<br />
Wall 150 240min<br />
Block work or<br />
Concrete wall<br />
Wall 150 240min<br />
Block work or<br />
Concrete wall<br />
Wall 150 240min<br />
Block work or<br />
Concrete wall<br />
Wall 200 240min<br />
Block work or<br />
Concrete wall<br />
Wall 215 240min<br />
Block work or<br />
Concrete wall<br />
Wall 200 240min<br />
Block work or<br />
Concrete wall<br />
Wall 200 240min<br />
Block work or<br />
Concrete wall<br />
Wall 200 240min<br />
Block work or<br />
Concrete wall<br />
Floor 150 240min<br />
Concrete Floor<br />
Floor 150 240min<br />
Concrete Floor<br />
Floor 150 240min<br />
Concrete Floor<br />
Floor 150 240min<br />
Concrete Floor<br />
Aperture<br />
Size<br />
(mm)<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
Coated Seal Detail<br />
Batt<br />
(layers &<br />
Thickness)<br />
1 x 60mm Lagged with<br />
500mm<br />
long<br />
x 40 thick<br />
Rockwool<br />
800<br />
insulation<br />
or Lagged<br />
with<br />
Fire<br />
Tube/Conlit<br />
pipe<br />
<strong>section</strong>s<br />
Penetration<br />
Type<br />
O/D wall<br />
thickness<br />
range<br />
(mm)<br />
Steel 88.9 / 4.0<br />
to<br />
170 / 8.0<br />
1 x 60mm Unlagged (8) Steel 17.1 / 2.3<br />
to<br />
168.3 / 7.1<br />
1 x 60mm Unlagged (8) Copper 15.0 / 0.7<br />
to<br />
108 / 1.5<br />
1 x 60mm Lagged with<br />
Fire<br />
Tube/Conlit<br />
pipe<br />
<strong>section</strong>s<br />
1 x 60mm Lagged with<br />
Fire<br />
Tube/Conlit<br />
pipe<br />
<strong>section</strong>s<br />
2 x 50mm<br />
(with<br />
100mm<br />
air gap)<br />
2 x 60mm<br />
(with 85<br />
mm<br />
air gap)<br />
2 x 50mm<br />
(with<br />
100mm<br />
air gap)<br />
2 x 50mm<br />
(with<br />
100mm<br />
air gap)<br />
2 x 50mm<br />
(with<br />
100mm<br />
air gap)<br />
Steel 17.1 / 2.3<br />
to<br />
168.3 / 7.1<br />
Copper 15.0 / 0.7<br />
to<br />
108 / 1.5<br />
Unlagged (8) Steel 17.1 / 2.3<br />
to<br />
168.3 / 7.1<br />
Unlagged (8) Steel 17.1 / 2.3<br />
to<br />
168.3 / 7.1<br />
Unlagged (8) Copper 15.0 / 0.7<br />
to<br />
108 / 1.5<br />
Lagged with<br />
Fire<br />
Tube/Conlit<br />
pipe<br />
<strong>section</strong>s<br />
Lagged with<br />
Fire<br />
Tube/Conlit<br />
pipe<br />
Steel 17.1 / 2.3<br />
to<br />
168.3 / 7.1<br />
Copper 15.0 / 0.7<br />
to<br />
108 / 1.5<br />
<strong>section</strong>s<br />
1 x 60mm Unlagged (8) Steel 17.1 / 2.3<br />
to<br />
168.3 / 7.1<br />
1 x 60mm Unlagged (8) Copper 15.0 / 0.7<br />
to<br />
108 / 1.5<br />
1 x 60mm Lagged with Steel 17.1 / 2.3<br />
Fire<br />
to<br />
Tube/Conlit<br />
168.3 / 7.1<br />
pipe<br />
<strong>section</strong>s<br />
1 x 60mm Lagged with<br />
Fire<br />
Tube/Conlit<br />
pipe<br />
<strong>section</strong>s<br />
Copper 15.0 / 0.7<br />
to<br />
108 / 1.5<br />
Fire<br />
Resistance<br />
Integrity /<br />
Insulation<br />
120 / 120<br />
240 / 0<br />
240 / 0<br />
180 / 120<br />
240 / 60 (6)<br />
240 / 0<br />
240 / 0<br />
240 / 0<br />
180 / 120<br />
240 / 60 (6)<br />
240 / 0<br />
240 / 0<br />
240 / 120<br />
240 / 120<br />
Cert.<br />
No.<br />
Notes<br />
1. The Fire Performance of the system will be dependant on the seal detail and Pipe type/ diameter. References should be made to<br />
manufactures literature and Chiltern International Fire Ltd Assessment Report: Chilt/A08152 rev B for further information.<br />
2. For Lightweight flexible wall constructions the <strong>part</strong>ition must be a minimum overall thickness of 130mm and be faced on each side<br />
with two layers of type F 15mm thick fire rated plasterboard or equivalent<br />
3. For Rigid wall constructions comprising of 150mm, 200mm or 215mm thick lightweight aerated concrete or block work shall have a<br />
minimum density of 750kg/m³.<br />
4. For Rigid floor constructions comprising of 150mm lightweight aerated concrete shall have a minimum density of 800kg/m³.<br />
5. Rockwool FirePro Ablative Coated batt has a density of 180kg/m³ comprising of a rock fibre core coated on both faces with 0.6 -<br />
0.8mm thick (1mm max) Rockwool FirePro Ablative coating, friction fitted centrally within the thickness of the wall and sealed to the<br />
construction on both faces with a 30mm x 30mm fillet of Rockwool Acoustic Intumescent Sealant.<br />
6. 120 minutes insulation performance can be achieved using 50mm thick Fire Tube/Conlit seals.<br />
7. Rockwool Insulated Fire sleeves must be fitted on all plastic pipes (30mm thick for pipe Ø up to 110mm and 35mm thick for pipe Ø<br />
above 110mm) as they pass by the Rockwool Ablative coated batt and protrude from each face by 45mm. The sleeve shall be<br />
sealed into position with a 15mm x 15mm fillet of Rockwool Acoustic Intumescent sealant on each face.<br />
8. Unlagged metal pipes must be sealed with Rockwool Acoustic and Intumescent sealant on both sides of the penetration.<br />
128 20 Nov 2011
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
Certificate No: 022b(5) to LPS1132: Issue 4<br />
Rockwool FirePro Ablative coated Batt - Cable Penetrations<br />
Product<br />
Name<br />
Rockwool<br />
FirePro<br />
Ablative<br />
Coated Batt<br />
Element of<br />
Constuction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 Block<br />
work/Concrete<br />
wall or 120min<br />
Lightweight<br />
flexible<br />
supporting<br />
construction<br />
Wall 150 240min Block<br />
work or<br />
Concrete wall<br />
Wall 150 240min Block<br />
work or<br />
Concrete wall<br />
Wall 150 240min Block<br />
work or<br />
Concrete wall<br />
Wall 150 240min Block<br />
work or<br />
Concrete wall<br />
Wall 150 240min Block<br />
work or<br />
Concrete wall<br />
Wall 150 240min Block<br />
work or<br />
Concrete wall<br />
Floor 150 240min<br />
Concrete Floor<br />
Floor 150 240min<br />
Concrete Floor<br />
Floor 150 240min<br />
Concrete Floor<br />
Floor 150 240min<br />
Concrete Floor<br />
Wall 150 240min<br />
Concrete or<br />
Block work<br />
Wall<br />
Wall 150 120min<br />
lightweight<br />
flexible<br />
supporting<br />
construction<br />
Aperture<br />
Size<br />
(mm)<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
1200<br />
1200 x<br />
1200<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
1200 x<br />
600<br />
Coated<br />
Batt<br />
(Layers<br />
&<br />
Thickness)<br />
Seal<br />
Details<br />
1 x 60mm 4mm conlit<br />
bandage<br />
1 x 60mm 4mm Conlit<br />
bandage<br />
1 x 60mm 4mm Conlit<br />
bandage<br />
1 x 60mm 4mm Conlit<br />
bandage<br />
1 x 60mm 4mm Conlit<br />
or 2 x 50mm bandage<br />
(100mm air<br />
gap)<br />
1 x 60mm 6mm Conlit<br />
or 2 x 50mm bandage (7)<br />
(100mm air<br />
gap)<br />
1 x 60mm 4mm Conlit<br />
or 2 x 50mm bandage<br />
(100mm air<br />
gap)<br />
1 x 60mm 6mm Conlit<br />
or 2 x 50mm bandage (7)<br />
(100mm air<br />
gap)<br />
1 x 60mm 6mm Conlit<br />
or 2 x 50mm bandage (7)<br />
(100mm air<br />
gap)<br />
1 x 60mm Rockwool<br />
or 2 x 50mm Acoustic<br />
(100mm air Intumescent<br />
gap) Sealant fillet<br />
1 x 60mm 6mm Conlit<br />
bandage (7)<br />
1 x 6mm 4mm Conlit<br />
bandage<br />
1 x 6mm 4mm Conlit<br />
bandage<br />
1 x 60mm 4mm Conlit<br />
bandage<br />
1 x 60mm 4mm Conlit<br />
bandage<br />
1 x 60mm 4mm Conlit<br />
bandage<br />
Sheathed<br />
Cables /<br />
Unsheathed<br />
Cables Type<br />
(6)<br />
All Sheathed<br />
Cabel types<br />
PVC<br />
Sheathed<br />
Cable types<br />
All Sheathed<br />
Cable types<br />
PVC<br />
Sheathed<br />
Cable types<br />
All Sheathed<br />
Cable types<br />
All Sheathed<br />
Cable types<br />
All Sheathed<br />
Cable types<br />
All Sheathed<br />
Cable types<br />
All Sheathed<br />
Cable types<br />
All Sheathed<br />
Cable types<br />
All Sheathed<br />
Cable types<br />
All Sheathed<br />
cables<br />
(excluding<br />
telecoms<br />
cables)<br />
Sheathed<br />
telecoms<br />
cables<br />
PVC<br />
Unsheathed<br />
cable types<br />
PVC<br />
Unsheathed<br />
cable types<br />
PVC<br />
Unsheathed<br />
cable types<br />
Cable<br />
Diameter<br />
(mm)<br />
Fire<br />
Resisitance<br />
Integrity /<br />
Insulation<br />
Cert.<br />
No.<br />
< 21 120 / 60 022b/06<br />
50 120 / 60<br />
< 21 90 / 60<br />
50 90 / 60<br />
< 21 120 / 60<br />
< 21 240 / 120<br />
22 to 50 60 / 60<br />
22 to 50 240 / 60<br />
51 to 80 120 / 60<br />
< 21 120 / 60<br />
< 21 240 / 60<br />
< 21 240 / 60<br />
< 21 120 / 60<br />
10 to 24 240 / 30<br />
10 to 24 120 / 30<br />
10 to 24 120 / 30<br />
Notes<br />
1. The Fire Performance of the system will be dependant on the seal detail and cable type/ diameter. References should be made to<br />
manufactures literature and Chiltern International Fire Ltd Assessment Report: Chilt/A08152 rev B for further information.<br />
2. For Lightweight flexible wall constructions the <strong>part</strong>ition must be a minimum overall thickness of 130mm and be faced on each side<br />
with two layers of type F 15mm thick fire rated plasterboard or equivalent<br />
3. For Rigid wall constructions comprising of 150mm, 200mm or 215mm thick lightweight aerated concrete or block work shall have a<br />
minimum density of 750kg/m³.<br />
20 Nov 2011 129
PART 1: SECTION 3<br />
LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS<br />
4. For Rigid floor constructions comprising of 150mm lightweight aerated concrete shall have a minimum density of 800kg/m³.<br />
5. Rockwool Ablative Coated batt has a density of 180kg/m³ comprising of a rock fibre core coated on both faces with 0.6 - 0.8mm thick<br />
(1mm max) Rockwool FirePro Ablative coating, friction fitted centrally within the thickness of the wall and sealed to the construction<br />
on both faces with a 30mm x 30mm fillet of Rockwool Acoustic Intumescent Sealant.<br />
6. All Cables shall be supported by steel ladders up to 340mm wide x 80mm deep or steel trays (perforated and un-perforated) up to<br />
460mm wide x 25mm deep at all performance periods.<br />
7. An Integrity performance of 240 minutes can be achieved if a 6 x 1mm layer Conlit ‘bandage’ is used which extends 300mm from<br />
each face of the Rockwool Ablative Coated batt.<br />
8. Cables may be individual or bundled where they penetrate the Rockwool FirePro Ablative Coated Batt system. Cable bundles are<br />
limited dependant on size and type of cables and sealing method, reference must be made to Chiltern International Fire Ltd<br />
Assessment Report: Chilt/A08152 rev B for details.<br />
Certificate No: 022b(5) to LPS 1132: Issue 4<br />
Rockwool Ablative Coated Batt - Blank Seals<br />
Product Name Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Rockwool FirePro<br />
Ablative Coated Batt<br />
Element of<br />
Construction<br />
Material<br />
Aperture<br />
Size<br />
(mm)<br />
Wall 150 Lightweight<br />
block work<br />
wall<br />
Floor 150 Lightweight<br />
aerated<br />
concrete floor<br />
Wall 215 Masonry wall 1200 x<br />
600<br />
Wall 130<br />
(Minimum)<br />
120 minute<br />
plasterboard<br />
<strong>part</strong>ition<br />
Coated<br />
Batt<br />
(Layers &<br />
Thickness)<br />
Fire<br />
Resistance<br />
Integrity /<br />
Insulation<br />
Cert.<br />
No.<br />
600 x 600 1 x 50mm 240 / 30 022b/06<br />
600 x 600 1 x 50mm 240 / 120<br />
1200 x<br />
600<br />
2 x 50mm 240 / 240<br />
(with<br />
100mm<br />
air gap)<br />
1 x 60mm 120 / 120<br />
Notes<br />
1. Rockwool Ablative Coated batt has a density of 180kg/m³ comprising of a rock fibre core coated on both faces with 0.6 - 0.8mm thick<br />
(1mm max) Rockwool FirePro Ablative coating, friction fitted centrally within the thickness of the wall and sealed to the construction<br />
on both faces with a 30mm x 30mm fillet of Rockwool Acoustic Intumescent Sealant.<br />
2. For Rigid wall constructions comprising of 150mm or 215mm thick lightweight aerated concrete or block work shall have a minimum<br />
density of 750kg/m³.<br />
3. For Rigid floor constructions comprising of 150mm lightweight aerated concrete shall have a minimum density of 800kg/m³.<br />
130 20 Nov 2011
PART 1: SECTION 4<br />
STRUCTURAL STEEL FIRE PROTECTION<br />
The protection of the structural integrity of a building is important for life safety of the occupants, fire fighters<br />
and for the cost-effective repair of the building post fire. When a building is involved in a fire, structural<br />
steelwork can resist the damaging effects of the high temperatures generated if suitably protected.<br />
20 Nov 2011 131
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
This <strong>section</strong> covers structural steel fire protection with use of board or cementitious coverings approved to<br />
LPS 1107 Requirements, Tests and Methods of Assessment of Passive Fire Protection Systems for Structural<br />
Steelwork.<br />
British Gypsum<br />
Head Office, East Leake, Loughborough, Leicester LE12 6HX, United Kingdom<br />
Tel: +44 ( 0)844 8001991 • Fax: +44 (0)844 5618816<br />
E-mail: bgtechnical.enquiries@bpb.com • Website: www.british-gypsum.com<br />
Certificate No: 162a to LPS 1107: Issue 1<br />
Product<br />
Name<br />
Glasroc F<br />
FIRECASE<br />
Exposure<br />
Internal<br />
only<br />
Internal<br />
only<br />
Internal<br />
only<br />
Internal<br />
only<br />
Internal<br />
only<br />
Board<br />
Thickness<br />
(mm)<br />
Performance at<br />
a critical<br />
steel<br />
temperature<br />
550 0 c<br />
Hp/A 30min<br />
Performance at<br />
a critical<br />
steel<br />
temperature<br />
550 0 c<br />
Hp/A 60min<br />
Performance at<br />
a critical<br />
steel<br />
temperature<br />
550 0 c<br />
Hp/A 90min<br />
Performance at<br />
a critical<br />
steel<br />
temperature<br />
550 0 c<br />
Hp/A 120 min<br />
Cert.<br />
No.<br />
15 260 260 105 65 162a/01<br />
20 260 260 180 90<br />
25 260 260 260 100<br />
30 260 260 260 250<br />
35 260 260 260 260<br />
Note:<br />
The 30mm and 35mm thickness of protection can be in two separately fixed layers, i.e., 15mm + 15mm and 15mm + 20mm.<br />
Promat UK Ltd<br />
The Sterling Centre, Eastern Road, Bracknell, Berkshire RG12 2TD, United Kingdom<br />
Tel: +44 (0)1344 381 300 • Fax: +44 (0)1344 381 301<br />
Website: www.promat-spray.co.uk<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a critical<br />
temperature of 350ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of:<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 14 19 27 35 762b/01<br />
40 12 12 17 22 32 42<br />
50 12 14 19 25 36 48<br />
60 12 15 21 27 40 52<br />
70 12 16 23 29 43 56<br />
80 12 17 24 31 45 60<br />
90 12 18 25 33 48 62<br />
100 12 19 26 34 50 65<br />
110 12 19 27 35 51 67<br />
120 12 20 28 36 53 69<br />
130 12 20 29 37 54 71<br />
140 12 21 29 38 55 -<br />
132 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of:<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
150 12 21 30 39 56 -<br />
160 13 22 30 39 57 -<br />
170 13 22 31 40 58 -<br />
180 13 22 31 41 59 -<br />
190 13 22 32 41 60 -<br />
200 13 23 32 42 61 -<br />
210 13 23 33 42 61 -<br />
220 14 23 33 43 62 -<br />
230 14 23 33 43 62 -<br />
240 14 24 33 43 63 -<br />
250 14 24 34 44 63 -<br />
260 14 24 34 44 64 -<br />
270 14 24 34 44 64 -<br />
280 14 24 34 44 65 -<br />
290 14 24 35 45 65 -<br />
300 14 25 35 45 65 -<br />
310 14 25 35 45 66 -<br />
320 14 25 35 45 66 -<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a critical<br />
temperature of 400ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 16 22 29 762b/01<br />
40 12 12 15 19 27 35<br />
50 12 12 17 22 31 40<br />
60 12 14 19 24 34 44<br />
70 12 15 20 26 36 47<br />
80 12 16 21 27 39 50<br />
90 12 16 23 29 41 53<br />
100 12 17 23 30 42 55<br />
110 12 18 24 31 44 57<br />
120 12 18 25 32 45 59<br />
130 12 19 26 33 47 60<br />
140 12 19 26 33 48 62<br />
150 12 20 27 34 49 63<br />
160 13 20 27 35 50 64<br />
170 13 20 28 35 50 65<br />
180 13 21 28 36 51 66<br />
190 13 21 29 36 52 67<br />
200 13 21 29 37 53 68<br />
210 14 21 29 37 53 69<br />
220 14 22 30 38 54 70<br />
230 14 22 30 38 54 70<br />
240 14 22 30 38 55 71<br />
250 14 22 30 39 55 72<br />
260 14 22 31 39 56 72<br />
270 14 23 31 39 56 -<br />
280 14 23 31 40 56 -<br />
290 14 23 31 40 57 -<br />
300 15 23 32 40 57 -<br />
20 Nov 2011 133
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
310 15 23 32 40 57 -<br />
320 15 23 32 40 58 -<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting I <strong>section</strong> beams with H <strong>section</strong> coloumns at a critical<br />
temperature of 450ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 15 21 27 762b/01<br />
40 12 12 14 18 25 33<br />
50 12 12 16 20 29 37<br />
60 12 13 17 22 32 41<br />
70 12 14 19 24 34 44<br />
80 12 14 20 25 36 47<br />
90 12 15 21 27 38 49<br />
100 12 16 22 28 40 52<br />
110 12 16 23 29 41 54<br />
120 12 17 23 30 42 55<br />
130 12 17 24 31 44 57<br />
140 12 18 25 31 45 58<br />
150 12 18 25 32 46 59<br />
160 12 19 26 33 47 61<br />
170 12 19 26 33 47 62<br />
180 12 19 26 34 48 62<br />
190 12 19 27 34 49 63<br />
200 12 20 27 35 49 64<br />
210 12 20 27 35 50 65<br />
220 13 20 28 35 50 66<br />
230 13 20 28 36 51 66<br />
240 13 20 28 36 51 67<br />
250 13 21 28 36 52 67<br />
260 13 21 29 37 52 68<br />
270 13 21 29 37 53 69<br />
280 13 21 29 37 53 69<br />
290 13 21 29 37 53 69<br />
300 13 21 29 38 54 70<br />
310 13 22 30 38 54 70<br />
320 13 22 30 38 54 71<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
134 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Cafco 300, required thickness when protection I <strong>section</strong> beams and H <strong>section</strong> columns at a critical<br />
temperature of 500ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 13 19 25 762b/01<br />
40 12 12 13 16 23 30<br />
50 12 12 14 18 26 34<br />
60 12 12 16 20 29 38<br />
70 12 12 17 22 31 41<br />
80 12 13 18 23 33 44<br />
90 12 14 19 24 35 46<br />
100 12 14 20 26 37 48<br />
110 12 15 21 27 38 50<br />
120 12 15 21 27 39 51<br />
130 12 16 22 28 41 53<br />
140 12 16 23 29 42 54<br />
150 12 17 23 30 42 55<br />
160 12 17 24 30 43 57<br />
170 12 17 24 31 44 58<br />
180 12 17 24 31 45 58<br />
190 12 18 25 32 45 59<br />
200 12 18 25 32 46 60<br />
210 12 18 25 32 47 61<br />
220 12 18 26 33 47 62<br />
230 12 19 26 33 48 62<br />
240 12 19 26 33 48 63<br />
250 12 19 26 34 49 63<br />
260 12 19 27 34 49 64<br />
270 12 19 27 34 49 64<br />
280 12 19 27 35 50 65<br />
290 12 20 27 35 50 65<br />
300 12 20 27 35 50 66<br />
310 12 20 27 35 51 66<br />
320 12 20 28 35 51 66<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a critical<br />
temperature of 550ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 12 18 23 762b/01<br />
40 12 12 12 15 21 28<br />
50 12 12 13 17 24 32<br />
60 12 12 14 19 27 35<br />
70 12 12 16 20 29 38<br />
80 12 12 17 21 31 41<br />
90 12 13 18 23 33 43<br />
100 12 13 18 24 34 45<br />
110 12 14 19 25 35 46<br />
120 12 14 20 25 37 48<br />
130 12 14 20 26 38 49<br />
140 12 15 21 27 39 51<br />
150 12 15 21 27 40 52<br />
20 Nov 2011 135
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
160 12 15 22 28 40 53<br />
170 12 16 22 28 41 54<br />
180 12 16 22 29 42 55<br />
190 12 16 23 29 42 56<br />
200 12 16 23 30 43 56<br />
210 12 17 23 30 44 57<br />
220 12 17 24 30 44 58<br />
230 12 17 24 31 45 58<br />
240 12 17 24 31 45 59<br />
250 12 17 24 31 45 59<br />
260 12 17 25 32 46 60<br />
270 12 18 25 32 46 60<br />
280 12 18 25 32 46 61<br />
290 12 18 25 32 47 61<br />
300 12 18 25 33 47 62<br />
310 12 18 25 33 47 62<br />
320 12 18 26 33 48 62<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a critical<br />
temperature of 600ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 minn<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 12 17 22 762b/01<br />
40 12 12 12 14 20 26<br />
50 12 12 12 16 23 30<br />
60 12 12 13 17 25 33<br />
70 12 12 14 19 27 36<br />
80 12 12 15 20 29 38<br />
90 12 12 16 21 31 40<br />
100 12 12 17 22 32 42<br />
110 12 12 18 23 33 44<br />
120 12 13 18 23 34 45<br />
130 12 13 19 24 35 46<br />
140 12 13 19 25 36 47<br />
150 12 14 19 25 37 48<br />
160 12 14 20 26 38 49<br />
170 12 14 20 26 38 50<br />
180 12 14 21 27 39 51<br />
190 12 15 21 27 39 52<br />
200 12 15 21 27 40 52<br />
210 12 15 21 28 40 53<br />
220 12 15 22 28 41 54<br />
230 12 15 22 28 41 54<br />
240 12 15 22 29 42 55<br />
250 12 16 22 29 42 55<br />
260 12 16 22 29 42 56<br />
270 12 16 23 29 43 56<br />
280 12 16 23 29 43 57<br />
290 12 16 23 30 43 57<br />
300 12 16 23 30 44 57<br />
310 12 16 23 30 44 58<br />
136 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 minn<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
320 12 16 23 30 44 58<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a critical<br />
temperature of 620ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 12 16 20 762b/01<br />
40 12 12 12 13 19 25<br />
50 12 12 12 15 22 28<br />
60 12 12 13 16 24 31<br />
70 12 12 14 18 26 34<br />
80 12 12 15 19 28 36<br />
90 12 12 15 20 29 38<br />
100 12 12 16 21 31 40<br />
110 12 12 17 22 32 42<br />
120 12 12 17 23 33 43<br />
130 12 13 18 23 34 44<br />
140 12 13 18 24 35 46<br />
150 12 13 19 24 35 47<br />
160 12 13 19 25 36 48<br />
170 12 14 19 25 37 48<br />
180 12 14 20 26 37 49<br />
190 12 14 20 26 38 50<br />
200 12 14 20 26 39 51<br />
210 12 14 21 27 39 51<br />
220 12 15 21 27 39 52<br />
230 12 15 21 27 40 52<br />
240 12 15 21 28 40 53<br />
250 12 15 21 28 41 53<br />
260 12 15 22 28 41 54<br />
270 12 15 22 28 41 54<br />
280 12 15 22 29 42 55<br />
290 12 16 22 29 42 55<br />
300 12 16 22 29 42 56<br />
310 12 16 22 29 43 56<br />
320 12 16 23 29 43 56<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
20 Nov 2011 137
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Cafco 300, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a critical<br />
temperature of 650ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 12 15 20 762b/01<br />
40 12 12 12 13 18 24<br />
50 12 12 12 14 21 28<br />
60 12 12 12 16 23 31<br />
70 12 12 13 17 25 33<br />
80 12 12 14 18 27 35<br />
90 12 12 15 19 28 37<br />
100 12 12 15 20 29 39<br />
110 12 12 16 21 31 40<br />
120 12 12 16 22 32 42<br />
130 12 12 17 22 33 43<br />
140 12 12 17 23 33 44<br />
150 12 12 18 23 34 45<br />
160 12 13 18 24 35 46<br />
170 12 13 18 24 35 47<br />
180 12 13 19 24 36 47<br />
190 12 13 19 25 37 48<br />
200 12 13 19 25 37 49<br />
210 12 14 20 25 37 49<br />
220 12 14 20 26 38 50<br />
230 12 14 20 26 38 51<br />
240 12 14 20 26 39 51<br />
250 12 14 20 27 39 51<br />
260 12 14 20 27 39 52<br />
270 12 14 21 27 40 52<br />
280 12 14 21 27 40 53<br />
290 12 14 21 27 40 53<br />
300 12 15 21 28 40 53<br />
310 12 15 21 28 41 54<br />
320 12 15 21 28 41 54<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a critical<br />
temperature of 700ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 12 13 18 762b/01<br />
40 12 12 12 12 16 22<br />
50 12 12 12 12 19 25<br />
60 12 12 12 14 21 28<br />
70 12 12 12 15 23 31<br />
80 12 12 12 16 24 33<br />
90 12 12 12 17 26 35<br />
100 12 12 13 18 27 36<br />
110 12 12 14 18 28 38<br />
120 12 12 14 19 29 39<br />
130 12 12 15 20 30 41<br />
140 12 12 15 20 31 42<br />
150 12 12 15 21 32 43<br />
138 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
160 12 12 16 21 33 44<br />
170 12 12 16 22 33 45<br />
180 12 12 16 22 34 45<br />
190 12 12 17 22 34 46<br />
200 12 12 17 23 35 47<br />
210 12 12 17 23 35 48<br />
220 12 12 17 23 36 48<br />
230 12 12 17 24 36 49<br />
240 12 12 18 24 37 49<br />
250 12 12 18 24 37 50<br />
260 12 12 18 24 37 50<br />
270 12 12 18 25 38 51<br />
280 12 12 18 25 38 51<br />
290 12 12 18 25 38 51<br />
300 12 12 18 25 39 52<br />
310 12 12 19 25 39 52<br />
320 12 12 19 26 39 53<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting hollow <strong>section</strong> beams and columns at a critical<br />
temperature of 350ºC<br />
Product<br />
Name<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 15 19 28 36 762b/01<br />
40 12 13 18 23 33 44<br />
50 12 14 20 26 38 50<br />
60 12 16 22 29 42 55<br />
70 12 17 24 32 46 60<br />
80 12 18 26 34 49 64<br />
90 12 19 28 36 52 68<br />
100 12 20 29 37 54 71<br />
110 12 21 30 39 57 -<br />
120 13 22 31 41 59 -<br />
130 13 23 32 42 61 -<br />
140 14 24 33 43 63 -<br />
150 14 24 34 45 65 -<br />
160 14 25 35 46 66 -<br />
170 15 25 36 47 68 -<br />
180 15 26 37 48 70 -<br />
190 15 27 38 49 71 -<br />
200 16 27 39 50 - -<br />
210 16 28 39 51 - -<br />
220 16 28 40 52 - -<br />
230 17 29 41 53 - -<br />
240 17 29 41 54 - -<br />
250 17 30 42 54 - -<br />
260 17 30 42 55 - -<br />
270 17 30 43 55 - -<br />
280 18 30 43 55 - -<br />
290 18 30 43 56 - -<br />
300 18 31 43 56 - -<br />
310 18 31 44 56 - -<br />
Cert.<br />
No.<br />
20 Nov 2011 139
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting hollow <strong>section</strong> beams and columns at a critical<br />
temperature of 400ºC<br />
Product<br />
Name<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 13 16 23 30 762b/01<br />
40 12 12 16 20 28 36<br />
50 12 13 18 23 32 42<br />
60 12 15 20 25 36 46<br />
70 12 16 22 27 39 50<br />
80 12 17 23 29 42 54<br />
90 12 18 24 31 44 57<br />
100 12 19 26 33 47 60<br />
110 12 20 27 34 49 63<br />
120 13 20 28 36 51 66<br />
130 13 21 29 37 53 68<br />
140 14 22 30 38 54 70<br />
150 14 23 31 39 56 -<br />
160 15 23 32 40 57 -<br />
170 15 24 33 41 59 -<br />
180 15 24 33 42 60 -<br />
190 16 25 34 43 62 -<br />
200 16 25 35 44 63 -<br />
210 16 26 35 45 64 -<br />
220 17 26 36 46 65 -<br />
230 17 27 37 47 67 -<br />
240 17 27 37 48 68 -<br />
250 17 28 38 48 69 -<br />
260 18 28 38 49 69 -<br />
270 18 28 39 49 70 -<br />
280 18 28 39 49 70 -<br />
290 18 29 39 50 71 -<br />
300 18 29 39 50 71 -<br />
310 18 29 40 50 72 -<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting hollow <strong>section</strong> beams and columns at a critical<br />
temperature 450ºC<br />
Product<br />
Name<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 15 21 28 762b/01<br />
40 12 12 14 18 26 34<br />
50 12 12 17 21 30 39<br />
60 12 13 18 23 33 43<br />
70 12 15 20 25 36 47<br />
80 12 16 21 27 39 51<br />
90 12 17 23 29 41 54<br />
100 12 17 24 31 44 57<br />
Cert.<br />
No.<br />
140 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
110 12 18 25 32 46 59<br />
120 12 19 26 33 48 62<br />
130 12 20 27 34 49 64<br />
140 13 20 28 36 51 66<br />
150 13 21 29 37 52 68<br />
160 13 21 30 38 54 70<br />
170 14 22 30 39 55 72<br />
180 14 23 31 40 57 -<br />
190 14 23 32 40 58 -<br />
200 15 24 32 41 59 -<br />
210 15 24 33 42 60 -<br />
220 15 24 34 43 61 -<br />
230 15 25 34 44 63 -<br />
240 16 25 35 45 64 -<br />
250 16 26 35 45 65 -<br />
260 16 26 36 46 65 -<br />
270 16 26 36 46 66 -<br />
280 16 26 36 46 66 -<br />
290 16 26 37 47 67 -<br />
300 17 27 37 47 67 -<br />
310 17 27 37 47 67 -<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting hollow <strong>section</strong> beams and columns at a critical<br />
temperature of 500ºC<br />
Product<br />
Name<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 14 20 25 762b/01<br />
40 12 12 13 17 24 31<br />
50 12 12 15 19 27 36<br />
60 12 12 17 21 31 40<br />
70 12 13 18 23 33 44<br />
80 12 14 20 25 36 47<br />
90 12 15 21 27 38 50<br />
100 12 16 22 28 40 53<br />
110 12 17 23 29 42 55<br />
120 12 17 24 31 44 58<br />
130 12 18 25 32 46 60<br />
140 12 18 26 33 47 62<br />
150 12 19 26 34 49 64<br />
160 12 20 27 35 50 65<br />
170 12 20 28 36 52 67<br />
180 13 21 29 37 53 69<br />
190 13 21 29 38 54 71<br />
200 13 21 30 38 55 72<br />
210 13 22 31 39 56 -<br />
220 14 22 31 40 57 -<br />
230 14 23 32 41 59 -<br />
240 14 23 32 41 60 -<br />
250 14 24 33 42 61 -<br />
260 14 24 33 42 61 -<br />
270 15 24 33 43 62 -<br />
Cert.<br />
No.<br />
20 Nov 2011 141
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
280 15 24 34 43 62 -<br />
290 15 24 34 43 62 -<br />
300 15 24 34 44 63 -<br />
310 15 25 34 44 63 -<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting hollow <strong>section</strong> beams and columns at a critical<br />
temperature of 550ºC<br />
Product<br />
Name<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(HP/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 13 18 24 762b/01<br />
40 12 12 12 15 22 29<br />
50 12 12 14 18 25 33<br />
60 12 12 15 20 28 37<br />
70 12 12 17 22 31 41<br />
80 12 13 18 23 33 44<br />
90 12 14 19 25 36 47<br />
100 12 14 20 26 38 49<br />
110 12 15 21 27 39 51<br />
120 12 16 22 28 41 54<br />
130 12 16 23 29 43 56<br />
140 12 17 24 30 44 58<br />
150 12 17 24 31 45 60<br />
160 12 18 25 32 47 61<br />
170 12 18 26 33 48 63<br />
180 12 19 26 34 49 64<br />
190 12 19 27 35 50 66<br />
200 12 20 28 36 52 67<br />
210 12 20 28 36 53 69<br />
220 12 20 29 37 54 70<br />
230 12 21 29 38 55 72<br />
240 13 21 30 38 56 -<br />
250 13 22 30 39 57 -<br />
260 13 22 31 39 57 -<br />
270 13 22 31 40 58 -<br />
280 13 22 31 40 58 -<br />
290 13 22 31 40 58 -<br />
300 13 22 31 41 59 -<br />
310 13 22 32 41 59 -<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
142 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Cafco 300, required thickness when protecting hollow <strong>section</strong> beams and columns at a critical<br />
temperature of 600ºC<br />
Product<br />
Name<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 12 17 22 762b/01<br />
40 12 12 12 14 21 27<br />
50 12 12 13 17 24 31<br />
60 12 12 14 18 27 35<br />
70 12 12 15 20 29 38<br />
80 12 12 17 22 31 41<br />
90 12 12 18 23 33 44<br />
100 12 13 19 24 35 46<br />
110 12 14 19 25 37 48<br />
120 12 14 20 26 38 50<br />
130 12 15 21 27 40 52<br />
140 12 15 22 28 41 54<br />
150 12 16 22 29 42 56<br />
160 12 16 23 30 44 57<br />
170 12 17 24 31 45 59<br />
180 12 17 24 31 46 60<br />
190 12 17 25 32 47 62<br />
200 12 18 25 33 48 63<br />
210 12 18 26 33 49 64<br />
220 12 18 26 34 50 65<br />
230 12 19 27 35 51 67<br />
240 12 19 27 35 52 68<br />
250 12 19 28 36 52 69<br />
260 12 20 28 36 53 70<br />
270 12 20 28 36 53 70<br />
280 12 20 28 37 54 71<br />
290 12 20 28 37 54 71<br />
300 12 20 29 37 54 72<br />
310 12 20 29 37 55 72<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting hollow <strong>section</strong> beams and columns at a critical<br />
temperature of 620ºC<br />
Product<br />
Name<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 12 16 21 762b/01<br />
40 12 12 12 14 20 26<br />
50 12 12 12 16 23 30<br />
60 12 12 13 17 25 33<br />
70 12 12 15 19 28 36<br />
80 12 12 16 21 30 39<br />
90 12 12 17 22 32 42<br />
100 12 12 18 23 34 44<br />
110 12 13 19 24 35 46<br />
120 12 14 19 25 37 48<br />
130 12 14 20 26 38 50<br />
140 12 15 21 27 39 52<br />
150 12 15 21 28 41 54<br />
160 12 16 22 29 42 55<br />
Cert.<br />
No.<br />
20 Nov 2011 143
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
170 12 16 23 29 43 57<br />
180 12 16 23 30 44 58<br />
190 12 17 24 31 45 59<br />
200 12 17 24 32 46 61<br />
210 12 17 25 32 47 62<br />
220 12 18 25 33 48 63<br />
230 12 18 26 34 49 64<br />
240 12 18 26 34 50 66<br />
250 12 19 27 35 51 67<br />
260 12 19 27 35 51 67<br />
270 12 19 27 35 52 68<br />
280 12 19 27 36 52 68<br />
290 12 19 28 36 52 69<br />
300 12 19 28 36 53 69<br />
310 12 20 28 36 53 70<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting hollow <strong>section</strong> beams and columns at a critical<br />
temperature of 650ºC<br />
Product<br />
Name<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 12 16 21 762b/01<br />
40 12 12 12 13 19 25<br />
50 12 12 12 15 22 29<br />
60 12 12 13 17 25 32<br />
70 12 12 14 18 27 35<br />
80 12 12 15 20 29 38<br />
90 12 12 16 21 31 40<br />
100 12 12 17 22 32 43<br />
110 12 12 18 23 34 45<br />
120 12 13 18 24 35 47<br />
130 12 13 19 25 37 48<br />
140 12 14 20 26 38 50<br />
150 12 14 20 27 39 52<br />
160 12 15 21 27 40 53<br />
170 12 15 22 28 41 55<br />
180 12 15 22 29 42 56<br />
190 12 16 23 29 43 57<br />
200 12 16 23 30 44 59<br />
210 12 16 24 31 45 60<br />
220 12 17 24 31 46 61<br />
230 12 17 24 32 47 62<br />
240 12 17 25 33 48 63<br />
250 12 17 25 33 49 64<br />
260 12 18 25 33 49 65<br />
270 12 18 26 34 49 65<br />
280 12 18 26 34 50 66<br />
290 12 18 26 34 50 66<br />
300 12 18 26 34 50 67<br />
310 12 18 26 35 51 67<br />
Cert.<br />
No.<br />
144 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco 300, required thickness when protecting hollow <strong>section</strong> beams and columns at a critical<br />
temperature of 700ºC<br />
Product<br />
Name<br />
Cafco<br />
300<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco 300<br />
for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 12 12 12 12 14 19 762b/01<br />
40 12 12 12 12 17 23<br />
50 12 12 12 13 20 27<br />
60 12 12 12 15 22 30<br />
70 12 12 12 16 24 33<br />
80 12 12 13 17 26 35<br />
90 12 12 14 18 28 38<br />
100 12 12 14 19 30 40<br />
110 12 12 15 20 31 42<br />
120 12 12 16 21 33 44<br />
130 12 12 16 22 34 46<br />
140 12 12 17 23 35 48<br />
150 12 12 18 24 37 49<br />
160 12 12 18 25 38 51<br />
170 12 12 19 25 39 52<br />
180 12 12 19 26 40 54<br />
190 12 13 20 27 41 55<br />
200 12 13 20 27 42 56<br />
210 12 13 20 28 43 57<br />
220 12 13 21 28 44 59<br />
230 12 14 21 29 44 60<br />
240 12 14 22 30 45 61<br />
250 12 14 22 30 46 62<br />
260 12 14 22 30 47 63<br />
270 12 14 22 31 47 63<br />
280 12 14 23 31 47 64<br />
290 12 15 23 31 48 64<br />
300 12 15 23 31 48 65<br />
310 12 15 23 32 48 65<br />
Cert.<br />
No.<br />
Notes:<br />
1. LPCB Ref 726b/01 - approval for Cafco 300 without accelerator, profile application applied in several coats dependant on thickness.<br />
2. LPCB Ref 726b/01 - Cafco 300 approved from the following manufacturing sites only; Promat UK Ltd, Lawn Road Industrial Estate,<br />
Carlton-in-Lindrick, Worksop, Notts S81 9LB UK and Cafco International LLC, Sharjah, UAE.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco Mandolite CP2, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a<br />
critical temperature of 350ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
Mandolite<br />
CP2<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 8 13 17 22 31 40 762b/02<br />
40 10 15 20 25 35 45<br />
50 10 16 21 27 38 49<br />
20 Nov 2011 145
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
60 11 17 23 29 40 52<br />
70 12 18 24 30 42 54<br />
80 12 18 25 31 44 56<br />
90 12 19 25 32 45 58<br />
100 13 19 26 33 46 59<br />
110 13 20 26 33 47 61<br />
120 13 20 27 34 48 62<br />
130 13 20 27 34 48 62<br />
140 13 21 28 35 49 63<br />
150 14 21 28 35 50 64<br />
160 14 21 28 35 50 65<br />
170 14 21 28 36 50 65<br />
180 14 21 29 36 51 66<br />
190 14 21 29 36 51 66<br />
200 14 22 29 37 52 66<br />
210 14 22 29 37 52 67<br />
220 14 22 29 37 52 67<br />
230 14 22 30 37 52 68<br />
240 14 22 30 37 53 68<br />
250 14 22 30 37 53 68<br />
260 14 22 30 38 53 68<br />
270 15 22 30 38 53 69<br />
280 15 22 30 38 53 69<br />
290 15 22 30 38 53 69<br />
300 15 22 30 38 54 69<br />
310 15 23 30 38 54 69<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco Mandolite CP2, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a<br />
critical temperature of 400ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
Mandolite<br />
CP2<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 8 11 15 19 27 35 762b/02<br />
40 8 13 17 22 31 40<br />
50 9 14 19 24 34 44<br />
60 10 15 20 26 37 47<br />
70 10 16 22 27 38 50<br />
80 11 17 22 28 40 52<br />
90 11 17 23 29 41 54<br />
100 11 18 24 30 43 55<br />
110 12 18 24 31 44 56<br />
120 12 18 25 31 44 57<br />
130 12 19 25 32 45 58<br />
140 12 19 26 32 46 59<br />
150 12 19 26 33 46 60<br />
160 13 19 26 33 47 61<br />
170 13 20 27 34 47 61<br />
180 13 20 27 34 48 62<br />
190 13 20 27 34 48 62<br />
146 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
200 13 20 27 34 49 63<br />
210 13 20 27 35 49 63<br />
220 13 20 28 35 49 64<br />
230 13 20 28 35 50 64<br />
240 13 21 28 35 50 64<br />
250 13 21 28 35 50 65<br />
260 13 21 28 36 50 65<br />
270 13 21 28 36 51 65<br />
280 14 21 28 36 51 66<br />
290 14 21 29 36 51 66<br />
300 14 21 29 36 51 66<br />
310 14 21 29 36 51 66<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco Mandolite CP2, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a<br />
critical temperature of 450ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
Mandolite<br />
CP2<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 8 10 13 17 24 31 762b/02<br />
40 8 11 15 20 28 36<br />
50 8 13 17 22 31 40<br />
60 9 14 18 23 33 43<br />
70 9 14 20 25 35 46<br />
80 10 15 20 26 37 48<br />
90 10 16 21 27 38 50<br />
100 10 16 22 28 40 51<br />
110 10 16 22 29 41 53<br />
120 11 17 23 29 41 54<br />
130 11 17 23 30 42 55<br />
140 11 17 24 30 43 56<br />
150 11 18 24 31 44 57<br />
160 11 18 25 31 44 57<br />
170 12 18 25 31 45 58<br />
180 12 18 25 32 45 59<br />
190 12 19 25 32 46 59<br />
200 12 19 26 32 46 60<br />
210 12 19 26 33 46 60<br />
220 12 19 26 33 47 61<br />
230 12 19 26 33 47 61<br />
240 12 19 26 33 47 61<br />
250 12 19 26 33 48 62<br />
260 12 19 27 34 48 62<br />
270 12 20 27 34 48 62<br />
280 12 20 27 34 48 63<br />
290 13 20 27 34 49 63<br />
300 13 20 27 34 49 53<br />
310 13 20 27 34 49 63<br />
20 Nov 2011 147
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco Mandolite CP2, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a<br />
critical temperature of 500ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
Mandolite<br />
CP2<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 8 8 12 15 21 27 762b/02<br />
40 8 10 14 17 25 32<br />
50 8 11 15 19 28 36<br />
60 8 12 17 21 30 39<br />
70 8 13 18 23 32 42<br />
80 8 14 19 24 34 44<br />
90 9 14 19 25 35 46<br />
100 9 15 20 26 37 47<br />
110 9 15 21 26 38 49<br />
120 10 15 21 27 39 50<br />
130 10 16 22 28 39 51<br />
140 10 16 22 28 40 52<br />
150 10 16 22 29 41 53<br />
160 10 17 23 29 41 54<br />
170 10 17 23 29 42 55<br />
180 11 17 23 30 42 55<br />
190 11 17 24 30 43 56<br />
200 11 17 24 30 43 56<br />
210 11 17 24 31 44 57<br />
220 11 18 24 31 44 57<br />
230 11 18 24 31 44 58<br />
240 11 18 25 31 45 58<br />
250 11 18 25 32 45 59<br />
260 11 18 25 32 45 59<br />
270 11 18 25 32 46 59<br />
280 11 18 25 32 46 60<br />
290 11 18 25 32 46 60<br />
300 12 18 25 32 46 60<br />
310 12 19 26 32 46 60<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco Mandolite CP2, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a<br />
critical temperature of 550ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
Mandolite<br />
CP2<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 8 8 10 13 18 24 762b/02<br />
40 8 9 12 15 22 29<br />
50 8 10 14 17 25 32<br />
60 8 11 15 19 27 36<br />
70 8 11 16 20 29 38<br />
80 8 12 17 21 31 40<br />
148 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
90 8 13 18 23 32 42<br />
100 8 13 18 23 34 44<br />
110 8 14 19 24 35 45<br />
120 9 14 19 25 36 47<br />
130 9 14 20 25 37 48<br />
140 9 15 20 26 37 49<br />
150 9 15 21 26 38 50<br />
160 9 15 21 27 39 51<br />
170 9 15 21 27 39 51<br />
180 10 16 22 28 40 52<br />
190 10 16 22 28 40 53<br />
200 10 16 22 28 41 53<br />
210 10 16 22 29 41 54<br />
220 10 16 23 29 42 54<br />
230 10 16 23 29 42 55<br />
240 10 17 23 29 42 55<br />
250 10 17 23 30 43 56<br />
260 10 17 23 30 43 56<br />
270 10 17 23 30 43 56<br />
280 10 17 24 30 43 57<br />
290 10 17 24 30 44 57<br />
300 10 17 24 31 44 57<br />
310 11 17 24 31 44 58<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco Mandolite CP2, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a<br />
critical temperature of 600ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
Mandolite<br />
CP2<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 8 8 9 11 16 21 762b/02<br />
40 8 8 10 13 20 26<br />
50 8 8 12 15 22 29<br />
60 8 9 13 17 24 32<br />
70 8 10 14 18 26 35<br />
80 8 11 15 19 28 37<br />
90 8 11 16 20 30 39<br />
100 8 12 16 21 31 40<br />
110 8 12 17 22 32 42<br />
120 8 12 18 23 33 43<br />
130 8 13 18 23 34 44<br />
140 8 13 18 24 35 45<br />
150 8 13 19 24 35 46<br />
160 8 14 19 25 36 47<br />
170 8 14 20 25 37 48<br />
180 8 14 20 26 37 49<br />
190 8 14 20 26 38 49<br />
200 9 14 20 26 38 50<br />
210 9 15 21 27 39 50<br />
220 9 15 21 27 39 51<br />
20 Nov 2011 149
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
230 9 15 21 27 39 52<br />
240 9 15 21 27 40 52<br />
250 9 15 21 28 40 52<br />
260 9 15 22 28 40 53<br />
270 9 15 22 28 41 53<br />
280 9 16 22 28 41 54<br />
290 9 16 22 28 41 54<br />
300 9 16 22 29 41 54<br />
310 9 16 22 29 42 55<br />
Cert.<br />
No.<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco Mandolite CP2, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a<br />
critical temperature of 620ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
Mandolite<br />
CP2<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 8 8 8 11 15 20 762b/02<br />
40 8 8 10 13 19 24<br />
50 8 8 11 15 21 28<br />
60 8 9 12 16 23 31<br />
70 8 10 13 17 25 33<br />
80 8 10 14 19 27 35<br />
90 8 11 15 20 28 37<br />
100 8 11 16 20 30 39<br />
110 8 12 16 21 31 40<br />
120 8 12 17 22 32 42<br />
130 8 12 17 22 33 43<br />
140 8 13 18 23 33 44<br />
150 8 13 18 24 34 45<br />
160 8 13 19 24 35 46<br />
170 8 13 19 24 35 46<br />
180 8 14 19 25 36 47<br />
190 8 14 19 25 37 48<br />
200 8 14 20 25 37 49<br />
210 8 14 20 26 37 49<br />
220 8 14 20 26 38 50<br />
230 8 14 20 26 38 50<br />
240 8 15 21 27 39 51<br />
250 9 15 21 27 39 51<br />
260 9 15 21 27 39 51<br />
270 9 15 21 27 40 52<br />
280 9 15 21 27 40 52<br />
290 9 15 21 28 40 53<br />
300 9 15 21 28 40 53<br />
310 9 15 22 28 41 53<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
150 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Cafco Mandolite CP2, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a<br />
critical temperature of 650ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
Mandolite<br />
CP2<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 8 8 9 10 14 19 762b/02<br />
40 8 8 9 12 17 23<br />
50 8 8 10 13 20 26<br />
60 8 8 11 15 22 29<br />
70 8 9 12 16 24 31<br />
80 8 9 13 17 25 33<br />
90 8 10 14 18 27 35<br />
100 8 10 15 19 28 37<br />
110 8 11 15 20 29 38<br />
120 8 11 16 20 30 39<br />
130 8 11 16 21 31 41<br />
140 8 12 17 22 32 42<br />
150 8 12 17 22 32 43<br />
160 8 12 17 23 33 43<br />
170 8 12 18 23 34 44<br />
180 8 13 18 23 34 45<br />
190 8 13 18 24 35 46<br />
200 8 13 18 24 35 46<br />
210 8 13 19 24 36 47<br />
220 8 13 19 25 36 47<br />
230 8 13 19 25 36 48<br />
240 8 13 19 25 37 48<br />
250 8 14 19 25 37 49<br />
260 8 14 20 26 37 49<br />
270 8 14 20 26 38 50<br />
280 8 14 20 26 38 50<br />
290 8 14 20 26 38 50<br />
300 8 14 20 26 39 51<br />
310 8 14 20 27 39 51<br />
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987<br />
Cafco Mandolite CP2, required thickness when protecting I <strong>section</strong> beams and H <strong>section</strong> columns at a<br />
critical temperature of 700ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
Cafco<br />
Mandolite<br />
CP2<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
30 8 8 8 8 12 16 762b/02<br />
40 8 8 8 10 15 20<br />
50 8 8 9 12 17 23<br />
60 8 8 10 13 19 26<br />
70 8 8 11 14 21 28<br />
80 8 8 12 15 23 30<br />
90 8 8 12 16 24 32<br />
100 8 9 13 17 25 33<br />
110 8 9 13 18 26 35<br />
120 8 9 14 18 27 36<br />
20 Nov 2011 151
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
30 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
60 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
90 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
120 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
180 min<br />
Applied<br />
Thickness<br />
(mm) of<br />
Cafco<br />
Mandolite<br />
CP2 for Fire<br />
Resistance<br />
Protection<br />
Periods of;<br />
240 min<br />
130 8 10 14 19 28 37<br />
140 8 10 15 19 29 38<br />
150 8 10 15 20 29 39<br />
160 8 10 15 20 30 40<br />
170 8 11 16 21 31 41<br />
180 8 11 16 21 31 41<br />
190 8 11 16 21 32 42<br />
200 8 11 16 22 32 43<br />
210 8 11 17 22 33 43<br />
220 8 12 17 22 33 44<br />
230 8 12 17 23 34 44<br />
240 8 12 17 23 34 45<br />
250 8 12 17 23 34 45<br />
260 8 12 18 23 35 46<br />
270 8 12 18 23 35 46<br />
280 8 12 18 24 35 47<br />
290 8 12 18 24 35 47<br />
300 8 12 18 24 36 47<br />
310 8 12 18 24 36 48<br />
Cert.<br />
No.<br />
Notes:<br />
1. LPCB Ref 726b/02 - profile application applied in several coats dependant on thickness.<br />
2. LPCB Ref 726b/02 - applied thicknesses quoted are without re-enforcement mesh included in coating.<br />
3. LPCB Ref 726b/02 - Cafco Mandolite CP2 approved from the following manufacturing site only; Promat UK Ltd, Lawn Road Industrial<br />
Estate, Carlton-in-Lindrick, Worksop, Notts S81 9LB UK.<br />
Rockwool Limited<br />
Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom<br />
Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302<br />
E-mail: info@rockwool.co.uk • Website: www.rockwool.co.uk<br />
Certificate No: 022d to LPS 1107: Issue 1<br />
Product Name Exposure Additional Information Cert.<br />
No.<br />
Rockwool FirePro(TM)<br />
BeamClad systems<br />
Internal and<br />
semi exposed<br />
Thickness range 25mm to 110mm. Fire resistance 30-240min (see tables<br />
below). Faced and unfaced boards are available, refer to manufacturer's<br />
technical literature for fixing details.<br />
022d/01<br />
3 Sided Protection of Steel Beams, Supporting Concrete/Composite Decks Using The Clip Fix Or Stud<br />
Welded Pins/Dry Joint System (critical failure temperature 620°C)<br />
Product Name Board Performance Performance Performance Performance Cert. No.<br />
Thickness<br />
(mm)<br />
Hp/A 30min Hp/A 60min Hp/A 90min Hp/A 120min<br />
BeamClad 25 260 260 260 95 022d/01<br />
30 260 260 260 124<br />
35 260 260 260 159<br />
40 260 260 260 200<br />
45 260 260 260 251<br />
50 260 260 260 260<br />
55 260 260 260 260<br />
60 260 260 260 260<br />
152 20 Nov 2011
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
3 Sided Protection Of Steel Beams, Supporting Concrete/Composite Decks Using The Bonded<br />
Noggin/Dry Joint System (critical failure temperature 620°C)<br />
Product Name Board Performance Performance Performance Performance Cert. No.<br />
Thickness<br />
(mm)<br />
Hp/A 30min Hp/A 60min Hp/A 90min Hp/A 120min<br />
BeamClad 25 260 260 196 73 022d/01<br />
30 260 260 260 93<br />
35 260 260 260 116<br />
40 260 260 260 143<br />
45 260 260 260 173<br />
50 260 260 260 209<br />
55 260 260 260 252<br />
60 260 260 260 260<br />
3 Sided Protection Of Steel Beams, Supporting Concrete/Composite Decks Using The Bonded Noggin<br />
Or Stud Welded Pins/Glued Joint System (critical failure temperature 620°C)<br />
Product<br />
Name<br />
Board<br />
Thickness<br />
Performance<br />
Hp/A 30min<br />
Performance<br />
Hp/A 60min<br />
Performance<br />
Hp/A 90min<br />
Performance<br />
Hp/A 120min<br />
Performance<br />
Hp/A 180min<br />
Performance<br />
Hp/A 240min<br />
Cert.<br />
No.<br />
(mm)<br />
BeamClad 25 260 260 260 168 52 - 022d/01<br />
30 260 260 260 235 65 -<br />
35 260 260 260 260 80 45<br />
40 260 260 260 260 95 53<br />
45 260 260 260 260 113 62<br />
50 260 260 260 260 132 70<br />
55 260 260 260 260 154 80<br />
60 260 260 260 260 178 90<br />
65 260 260 260 260 206 100<br />
70 260 260 260 260 237 112<br />
75 260 260 260 260 260 124<br />
80 260 260 260 260 260 136<br />
85 260 260 260 260 260 150<br />
90 260 260 260 260 260 165<br />
95 260 260 260 260 260 181<br />
100 260 260 260 260 260 199<br />
110 260 260 260 260 260 238<br />
4 Sided Protection Of Steel Beams And Columns Using The Clip Fix Or Stud Welded Pins/Dry Joint<br />
System (critical failure temperature 550°C)<br />
Product Name Board Performance Performance Performance Performance Cert. No.<br />
Thickness<br />
(mm)<br />
Hp/A 30min Hp/A 60min Hp/A 90min Hp/A 120min<br />
BeamClad 25 260 260 148 65 022d/01<br />
30 260 260 260 84<br />
35 260 260 260 104<br />
40 260 260 260 128<br />
45 260 260 260 155<br />
50 260 260 260 187<br />
55 260 260 260 225<br />
60 260 260 260 260<br />
4 Sided Protection Of Steel Beams And Columns Using The Bonded Noggin/Dry Joint System (critical<br />
failure temperature 550°C)<br />
Product Name Board Performance Performance Performance Performance Cert. No.<br />
Thickness<br />
(mm)<br />
Hp/A<br />
30min<br />
Hp/A<br />
60min<br />
Hp/A<br />
90min<br />
Hp/A<br />
120min<br />
BeamClad 25 260 260 146 65 022d/01<br />
30 260 260 202 83<br />
35 260 260 260 103<br />
40 260 260 260 126<br />
45 260 260 260 153<br />
50 260 260 260 184<br />
55 260 260 260 221<br />
20 Nov 2011 153
PART 1: SECTION 4.1<br />
LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS<br />
Product Name<br />
Board<br />
Thickness<br />
(mm)<br />
Performance<br />
Hp/A<br />
30min<br />
Performance<br />
Hp/A<br />
60min<br />
Performance<br />
Hp/A<br />
90min<br />
Performance<br />
Hp/A<br />
120min<br />
60 260 260 260 260<br />
Cert. No.<br />
4 Sided Protection Of Steel Columns Using The Bonded Noggin Or Stud Welded Pins/Glued Joint<br />
System (critical failure temperature 550°C)<br />
Product<br />
Name<br />
Board<br />
Thickness<br />
Performance<br />
Hp/A<br />
Performance<br />
Hp/A<br />
Performance<br />
Hp/A<br />
Performance<br />
Hp/A<br />
Performance<br />
Hp/A<br />
Performance<br />
Hp/A<br />
Cert.<br />
No.<br />
(mm) 30min 60min 90min 120min 180min 240min<br />
BeamClad 25 260 260 149 65 - - 022d/01<br />
30 260 260 207 83 - -<br />
35 260 260 260 104 45 -<br />
40 260 260 260 128 54 -<br />
45 260 260 260 155 62 -<br />
50 260 260 260 187 72 44<br />
55 260 260 260 225 82 50<br />
60 260 260 260 260 92 55<br />
65 260 260 260 260 104 61<br />
70 260 260 260 260 116 68<br />
75 260 260 260 260 129 74<br />
80 260 260 260 260 143 81<br />
85 260 260 260 260 159 88<br />
90 260 260 260 260 176 96<br />
95 260 260 260 260 194 103<br />
100 260 260 260 260 214 124<br />
110 260 260 260 260 260 129<br />
4 Sided Protection Of Steel Beams Using The Bonded Noggin Or Stud Welded Pins/Glued Joint<br />
System (critical failure temperature 550°C)<br />
Product<br />
Name<br />
Board<br />
Thickness<br />
(mm)<br />
Performance<br />
Hp/A<br />
30min<br />
Performance<br />
Hp/A<br />
60min<br />
Performance<br />
Hp/A<br />
90min<br />
Performance<br />
Hp/A<br />
120min<br />
Performance<br />
Hp/A<br />
180min<br />
Performance<br />
Hp/A<br />
240min<br />
BeamClad 25 260 260 260 98 40 - 022d/01<br />
30 260 260 260 130 50 -<br />
35 260 260 260 168 61 -<br />
40 260 260 260 216 73 43<br />
45 260 260 260 260 85 50<br />
50 260 260 260 260 99 57<br />
55 260 260 260 260 114 65<br />
65 260 260 260 260 131 73<br />
65 260 260 260 260 150 81<br />
70 260 260 260 260 170 90<br />
75 260 260 260 260 193 99<br />
80 260 260 260 260 219 109<br />
85 260 260 260 260 248 120<br />
90 260 260 260 260 260 131<br />
95 260 260 260 260 260 144<br />
100 260 260 260 260 260 157<br />
110 260 260 260 260 260 186<br />
Cert.<br />
No.<br />
154 20 Nov 2011
PART 1: SECTION 4.2<br />
STRUCTURAL STEEL FIRE PROTECTION - INTUMESCENT THIN FILM COATINGS<br />
The protection of the structural integrity of a building is important for life safety of the occupants, fire fighters<br />
and for the cost-effective repair of the building post fire. When a building is involved in a fire, structural<br />
steelwork can resist the damaging effects of the high temperatures generated if suitably protected.<br />
This <strong>section</strong> covers structural steel fire protection with use of intumescent thin film coatings approved to<br />
SD075 Fire Protection for Structural Steelwork (Intumescent Systems) (BS 476: Parts 20 & 21).<br />
Promat UK Ltd<br />
The Sterling Centre, Eastern Road, Bracknell, Berkshire RG12 2TD, United Kingdom<br />
Tel: +44 (0)1344 381 300 • Fax: +44 (0)1344 381 301<br />
Website: www.promat-spray.co.uk<br />
Certificate No: 762a to SD075 - BS 476: Parts 20 & 21<br />
Cafco Sprayfilm WB3 Intumescent Paint, 4 Sided Protection on Hollow Sections 532ºC<br />
Product<br />
Name<br />
SprayFilm<br />
WB3<br />
Section<br />
Factor<br />
(Hp/A)<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
30 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
60 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
90 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
120 min<br />
Up to 45 0.61 0.61 1.80 3.51 762a/01<br />
45-50 0.61 0.61 1.80 3.51<br />
51-55 0.61 0.61 1.80 3.51<br />
56-60 0.61 0.61 1.80 3.51<br />
61-65 0.61 0.61 1.90 3.51<br />
66-70 0.61 0.61 2.00 3.51<br />
71-75 0.61 0.61 2.10 3.51<br />
76-80 0.61 0.61 2.19 3.51<br />
81-85 0.61 0.61 <strong>2.2</strong>9 3.51<br />
86-90 0.61 0.61 2.39 3.51<br />
91-95 0.61 0.69 2.49 3.51<br />
96-100 0.61 0.78 2.55 3.59<br />
101-105 0.61 0.86 2.62 3.99<br />
106-110 0.61 0.94 2.67 4.39<br />
111-115 0.61 1.06 2.72 4.80<br />
116-120 0.61 1.08 2.77 5.20<br />
121-125 0.61 1.11 2.83 5.60<br />
126-130 0.61 1.14 2.88 6.00<br />
131-135 0.61 1.17 2.93 -<br />
136-140 0.61 1.20 2.98 -<br />
141-145 0.61 1.23 3.03 -<br />
146-150 0.61 1.26 3.08 -<br />
151-155 0.61 1.29 3.13 -<br />
156-160 0.61 1.32 3.18 -<br />
161-165 0.61 1.35 3.25 -<br />
166-170 0.61 1.38 3.29 -<br />
171-175 0.61 1.41 3.34 -<br />
176-180 0.61 1.45 3.39 -<br />
181-185 0.61 1.48 3.44 -<br />
186-190 0.61 1.51 3.51 -<br />
191-195 0.61 1.54 3.61 -<br />
196-200 0.61 1.57 3.77 -<br />
201-205 0.61 1.60 3.93 -<br />
206-210 0.61 1.63 4.08 -<br />
211-215 0.61 1.66 4.24 -<br />
216-220 0.61 1.69 4.40 -<br />
221-225 0.61 1.72 4.56 -<br />
226-230 0.61 1.75 4.72 -<br />
231-235 0.61 1.78 4.88 -<br />
236-240 0.61 1.83 5.04 -<br />
241-245 0.61 1.91 5.20 -<br />
246-250 0.61 1.99 5.36 -<br />
Cert.<br />
No.<br />
20 Nov 2011 155
PART 1: SECTION 4.2<br />
STRUCTURAL STEEL FIRE PROTECTION - INTUMESCENT THIN FILM COATINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
30 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
60 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
90 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
120 min<br />
251-255 0.61 2.07 5.52 -<br />
256-260 0.61 2.15 5.68 -<br />
261-265 0.61 <strong>2.2</strong>3 5.84 -<br />
266-270 0.61 2.31 6.00 -<br />
271-275 0.61 2.39 - -<br />
276-280 0.61 2.47 - -<br />
281-285 0.61 2.55 - -<br />
286-290 0.61 2.62 - -<br />
291-295 0.61 2.68 - -<br />
296-300 0.61 2.75 - -<br />
301-305 0.61 2.82 - -<br />
306-310 0.61 2.88 - -<br />
311-315 0.61 2.95 - -<br />
316-320 0.61 3.02 - -<br />
Cert.<br />
No.<br />
Notes:<br />
1. LPCB Ref 762a/01 - Intumescent dry film thickness excludes any primer or top coat film thickness.<br />
2. LPCB Ref 762a/01 - SprayFilm WB3 approved from the following manufacturing sites; Promat UK Ltd, Lawn Road Industrial Estate,<br />
Carlton-in-Lindrick, Worksop, Notts S81 9LB UK and Comais Srl, Via Provinciale, 10 - Filago (BG), 24040 Italy (FPC Ref. 935).<br />
Certificate No: 762a to SD075 - BS 476: Parts 20 & 21<br />
Cafco Sprayfilm WB3 Intumescent Paint, 3 Sided Protection On I Section Beams (continuous concrete<br />
topping) 620ºC<br />
Product<br />
Cert.<br />
Name<br />
No.<br />
SprayFilm<br />
WB3<br />
Section<br />
Factor<br />
(Hp/A)<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
30 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
60 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
90 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
120 min<br />
Up to 45 0.23 0.25 1.20 1.20 762a/01<br />
45-50 0.23 0.25 1.20 1.20<br />
51-55 0.23 0.25 1.20 1.20<br />
56-60 0.23 0.25 1.20 1.20<br />
61-65 0.23 0.25 1.20 1.20<br />
66-70 0.23 0.25 1.20 1.23<br />
71-75 0.23 0.25 1.20 1.28<br />
76-80 0.23 0.27 1.20 1.33<br />
81-85 0.23 0.28 1.20 1.39<br />
86-90 0.23 0.30 1.20 1.44<br />
91-95 0.23 0.32 1.20 1.49<br />
96-100 0.23 0.34 1.20 1.63<br />
101-105 0.23 0.36 1.20 1.78<br />
106-110 0.23 0.38 1.20 1.94<br />
111-115 0.23 0.40 1.20 2.04<br />
116-120 0.23 0.42 1.20 2.10<br />
121-125 0.23 0.44 1.22 2.17<br />
126-130 0.23 0.46 1.25 <strong>2.2</strong>3<br />
131-135 0.23 0.48 1.28 2.30<br />
136-140 0.23 0.50 1.31 2.36<br />
141-145 0.23 0.52 1.34 2.43<br />
146-150 0.23 0.54 1.37 2.49<br />
151-155 0.23 0.56 1.40 2.56<br />
156-160 0.23 0.57 1.43 2.62<br />
161-165 0.23 0.57 1.46 2.69<br />
166-170 0.23 0.57 1.49 2.75<br />
171-175 0.23 0.61 1.54 2.82<br />
176-180 0.23 0.64 1.60 2.88<br />
181-185 0.23 0.67 1.66 2.95<br />
186-190 0.23 0.70 1.72 3.01<br />
191-195 0.23 0.73 1.78 3.18<br />
196-200 0.23 0.76 1.84 3.33<br />
201-205 0.23 0.80 1.90 3.48<br />
156 20 Nov 2011
PART 1: SECTION 4.2<br />
STRUCTURAL STEEL FIRE PROTECTION - INTUMESCENT THIN FILM COATINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
30 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
60 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
90 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
120 min<br />
206-210 0.23 0.83 1.96 3.64<br />
211-215 0.24 0.86 2.02 3.79<br />
216-220 0.24 0.88 2.07 3.94<br />
221-225 0.24 0.89 2.12 4.21<br />
226-230 0.24 0.91 2.17 4.57<br />
231-235 0.24 0.93 <strong>2.2</strong>2 4.93<br />
236-240 0.25 0.94 <strong>2.2</strong>7 5.29<br />
241-245 0.25 0.96 2.32 5.64<br />
246-250 0.25 0.97 2.37 6.00<br />
251-255 0.25 0.99 2.42 -<br />
256-260 0.25 1.00 2.47 -<br />
261-265 0.26 1.02 2.52 -<br />
266-270 0.26 1.04 2.57 -<br />
271-275 0.27 1.05 2.62 -<br />
276-280 0.28 1.07 2.67 -<br />
281-285 0.28 1.08 2.72 -<br />
286-290 0.29 1.10 2.77 -<br />
291-295 0.29 1.11 2.82 -<br />
296-300 0.30 1.13 2.87 -<br />
301-305 0.30 1.14 2.92 -<br />
306-310 0.31 1.16 2.97 -<br />
311-315 0.31 1.18 3.02 -<br />
316-320 0.31 1.19 3.22 -<br />
Cert.<br />
No.<br />
Certificate No: 762a to SD075 - BS 476: Parts 20 & 21<br />
Cafco Sprayfilm WB3 Intumescent Paint, 4 Sided Protection On I Section Beams 550ºC<br />
Product<br />
Name<br />
SprayFilm<br />
WB3<br />
Section<br />
Factor<br />
(Hp/A)<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
30 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
60 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
90 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
120 min<br />
Up to 45 0.23 0.57 1.20 1.20 762a/01<br />
45-50 0.23 0.57 1.20 1.25<br />
51-55 0.23 0.57 1.20 1.31<br />
56-60 0.23 0.57 1.20 1.38<br />
61-65 0.23 0.57 1.20 1.46<br />
66-70 0.23 0.57 1.20 1.53<br />
71-75 0.23 0.57 1.20 1.75<br />
76-80 0.23 0.57 1.20 1.93<br />
81-85 0.23 0.57 1.20 2.05<br />
86-90 0.23 0.57 1.20 2.13<br />
91-95 0.23 0.57 1.20 <strong>2.2</strong>1<br />
96-100 0.23 0.57 1.20 <strong>2.2</strong>9<br />
101-105 0.23 0.57 1.25 2.37<br />
106-110 0.23 0.57 1.30 2.44<br />
111-115 0.23 0.57 1.35 2.52<br />
116-120 0.23 0.57 1.40 2.60<br />
121-125 0.23 0.57 1.45 2.68<br />
126-130 0.23 0.63 1.50 2.76<br />
131-135 0.23 0.68 1.60 2.84<br />
136-140 0.23 0.74 1.69 2.92<br />
141-145 0.23 0.79 1.79 3.00<br />
146-150 0.23 0.85 1.88 3.13<br />
151-155 0.23 0.88 1.98 3.25<br />
156-160 0.23 0.90 2.04 3.38<br />
161-165 0.23 0.92 2.08 3.50<br />
166-170 0.23 0.94 2.13 3.63<br />
171-175 0.24 0.96 2.18 3.75<br />
176-180 0.24 0.98 <strong>2.2</strong>2 3.88<br />
181-185 0.24 1.00 <strong>2.2</strong>7 4.00<br />
186-190 0.24 1.02 2.32 4.31<br />
191-195 0.24 1.04 2.36 4.63<br />
Cert.<br />
No.<br />
20 Nov 2011 157
PART 1: SECTION 4.2<br />
STRUCTURAL STEEL FIRE PROTECTION - INTUMESCENT THIN FILM COATINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
30 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
60 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
90 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
120 min<br />
196-200 0.25 1.05 2.41 4.94<br />
201-205 0.25 1.07 2.46 5.25<br />
206-210 0.25 1.09 2.50 5.56<br />
211-215 0.25 1.11 2.55 5.88<br />
216-220 0.26 1.13 2.60 6.19<br />
221-225 0.27 1.15 2.64 -<br />
226-230 0.27 1.17 2.69 -<br />
231-235 0.28 1.19 2.74 -<br />
236-240 0.29 1.21 2.79 -<br />
241-245 0.30 1.23 2.83 -<br />
246-250 0.30 1.25 2.88 -<br />
251-255 0.31 1.27 2.93 -<br />
256-260 0.32 1.29 2.97 -<br />
261-265 0.32 1.31 3.02 -<br />
266-270 0.33 1.33 3.23 -<br />
271-275 0.34 1.35 3.39 -<br />
276-280 0.35 1.37 3.55 -<br />
281-285 0.35 1.39 3.71 -<br />
286-290 0.36 1.41 3.87 -<br />
291-295 0.37 1.43 4.03 -<br />
296-300 0.38 1.45 4.31 -<br />
301-305 0.38 1.47 4.56 -<br />
306-310 0.39 1.49 4.82 -<br />
311-315 0.40 1.51 5.08 -<br />
316-320 0.40 1.54 5.33 -<br />
Cert.<br />
No.<br />
Certificate No: 762a/01 to SD075 - BS 476: Parts 20 & 21<br />
Cafco Sprayfilm WB3 Intumescent Paint, 4 Sided Protection On I Section Columns 550ºC<br />
Product<br />
Name<br />
SprayFilm<br />
WB3<br />
Section<br />
Factor<br />
(Hp/A)<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
30 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
60 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
90 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
120 min<br />
Up to 45 0.23 0.60 1.50 1.50 762a/01<br />
45-50 0.23 0.60 1.50 1.50<br />
51-55 0.23 0.60 1.50 1.50<br />
56-60 0.23 0.60 1.50 1.50<br />
61-65 0.23 0.60 1.50 1.50<br />
66-70 0.23 0.60 1.50 1.67<br />
71-75 0.23 0.60 1.50 1.83<br />
76-80 0.23 0.60 1.50 2.00<br />
81-85 0.23 0.60 1.50 2.08<br />
86-90 0.23 0.60 1.50 2.15<br />
91-95 0.23 0.60 1.50 <strong>2.2</strong>3<br />
96-100 0.23 0.60 1.50 2.31<br />
101-105 0.23 0.60 1.50 2.38<br />
106-110 0.23 0.60 1.50 2.46<br />
111-115 0.23 0.60 1.50 2.54<br />
116-120 0.23 0.60 1.50 2.62<br />
121-125 0.23 0.66 1.57 2.69<br />
126-130 0.23 0.71 1.62 2.77<br />
131-135 0.23 0.75 1.67 2.85<br />
136-140 0.23 0.80 1.72 2.92<br />
141-145 0.23 0.85 1.78 3.00<br />
146-150 0.23 0.87 1.83 3.11<br />
151-155 0.23 0.88 1.88 3.23<br />
156-160 0.24 0.89 1.93 3.34<br />
161-165 0.24 0.90 1.98 3.45<br />
166-170 0.24 0.90 2.03 3.57<br />
171-175 0.24 0.91 2.08 3.68<br />
176-180 0.24 0.92 2.14 3.80<br />
181-185 0.25 0.92 2.19 3.91<br />
Cert.<br />
No.<br />
158 20 Nov 2011
PART 1: SECTION 4.2<br />
STRUCTURAL STEEL FIRE PROTECTION - INTUMESCENT THIN FILM COATINGS<br />
Product<br />
Name<br />
Section<br />
Factor<br />
(Hp/A)<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
30 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
60 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
90 min<br />
Intumescent Dry<br />
Film Thickness<br />
(mm)<br />
for Protection<br />
Periods of:<br />
120 min<br />
186-190 0.25 0.93 <strong>2.2</strong>4 4.02<br />
191-195 0.25 0.94 <strong>2.2</strong>9 4.43<br />
196-200 0.25 0.95 2.34 4.79<br />
201-205 0.25 0.95 2.40 5.14<br />
206-210 0.26 0.96 2.45 5.50<br />
211-215 0.26 0.97 2.50 5.86<br />
216-220 0.27 0.97 2.55 6.21<br />
221-225 0.27 0.98 2.60 -<br />
226-230 0.28 0.99 2.66 -<br />
231-235 0.28 1.00 2.71 -<br />
236-240 0.29 1.00 2.76 -<br />
241-245 0.29 1.04 2.81 -<br />
246-250 0.30 1.06 2.86 -<br />
251-255 0.30 1.09 2.92 -<br />
256-260 0.31 1.12 2.97 -<br />
261-265 0.31 1.14 3.02 -<br />
266-270 0.32 1.17 3.14 -<br />
271-275 0.32 1.19 3.24 -<br />
276-280 0.33 1.22 3.34 -<br />
281-285 0.33 1.25 3.44 -<br />
286-290 0.34 1.27 3.54 -<br />
291-295 0.34 1.30 3.64 -<br />
296-300 0.35 1.33 3.74 -<br />
301-305 0.35 1.35 3.84 -<br />
306-310 0.36 1.38 3.94 -<br />
311-315 0.36 1.41 4.04 -<br />
316-320 0.37 1.43 4.32 -<br />
Cert.<br />
No.<br />
Note: Intumescent dry film thickness exclude any primer or top coat film thickness.<br />
20 Nov 2011 159
PART 1: SECTION 5<br />
PROTECTIVE COVERING MATERIALS & SCAFFOLD CLADDING<br />
This <strong>section</strong> includes LPS 1207 Fire requirements for protective covering materials which are used during the<br />
construction of new buildings and renovation of existing buildings, and LPS 1215 Requirements for the LPCB<br />
Approval and Listing of Scaffold cladding materials.<br />
160 20 Nov 2011
PART 1: SECTION 5.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS<br />
During the construction of new buildings and renovation of existing buildings, it is common to use sheeting<br />
made from plastic or similar materials to provide protection against the weather, dust and other materials<br />
produced by work in adjacent areas. If a material complies with LPS 1207 Fire requirements for protective<br />
covering materials it will not add significantly to the fire risk. This standard is referred to in The Joint Code of<br />
Practice on the Protection from Fire of Construction Sites & Buildings Undergoing Renovation, 7th Edition<br />
published by the FPA in association with RISC Authority<br />
20 Nov 2011 161
PART 1: SECTION 5.1.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING<br />
Bainbridge International Limited<br />
Unit 8, Flanders Park, Flanders Road, Hedge End, Southampton, Hampshire SO30 2FZ, United Kingdom<br />
Tel: 01489 776050 • Fax: 01489 776055<br />
E-mail: info@coverguard.com • Website: www.coverguard.com<br />
Certificate No: 1058a to LPS 1207 Issue 2<br />
Product Name Thickness (mm) Weight (g/m²) Cert. No.<br />
Wall cover guard (CG0636TF & CG06272TF) 0.15 ± 15% 150 ± 10% 1058a/01<br />
Floor cover guard (CG1036DP-CG4036DP) 0.25 - 1.0 ± 15% 250 - 1000 ± 10% 1058a/02<br />
Scaffold cover guard (CG0872SC) 0.2 ± 15% 286 ± 10% 1058a/03<br />
Notes:<br />
1. LPCB Ref 1058a/01 & 1058a/02 Wall and Floor cover guard is available in blue only and covers non printed material with a printed<br />
product marking bands as required by LPS1207 Issue 2 Clause 4 only.<br />
2. LPCB Ref 1058a/03 Scaffold cover guard is available in white only and covers non printed material with a printed product marking<br />
band as required by LPS1207 Issue 2 Clause 4 only.<br />
BPI Visqueen - Greenock<br />
96 Port Glasgow Road, Greenock, Scotland PA15 2UL, United Kingdom<br />
Tel: +44 (0)1475 501100 • Fax: +44 (0)1475 743256<br />
Website: www.bpipoly.com<br />
Certificate No: 521a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness Weight Cert. No.<br />
(mm) (g/m 2 )<br />
Megafilm Flame Retardant Polythene Protection Films (Visqueen Megafilm) 0.065 to 0.5 - 521a/01<br />
Visqueen Flame Retardant Polythene Protection Films (Portathene WRE50) 0.03 to 0.5 - 521a/02<br />
Note:<br />
1. LPCB Ref. No. 521a/01 - Megafilm products can be supplied in various flat and textured profiles, and is available in a variety of<br />
colours.<br />
Certificate No: 688a-x4 to LPS1207: Issue 2<br />
Product Name Thickness (mm) Weight (g/m2) Cert. No.<br />
Megaboard Twinwall Polyrpopylene 2.0 - 4.5mm 250 - 1000 688a-x4/01<br />
Megaboard Recycled FR 2.0 250 688a-x4/02<br />
Notes:<br />
1. LPCB Ref No. 688a-x4/01 is available in white only and covers printed and non printed material with a product marking band as<br />
required by LPS 1207: Issue 2 Clause 4.<br />
2. LPCB Ref.No. 688a-x4/02 is available in black only and covers non printed material with a printed product marking band as required<br />
by LPS 1207: Issue 2 Clause 4 only.<br />
Britton Merlin Limited<br />
Brackenborough Road, Louth, Lincolnshire LN11 0AX, United Kingdom<br />
Tel: +44 (0)1507 617800 • Fax: +44 (0)1507 601681<br />
E-mail: tuffreel@britton-group.com<br />
Certificate No: 499a to LPS 1207: Issue 2.1<br />
162 20 Nov 2011
PART 1: SECTION 5.1.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Tuffreel Flame Retardant (G6) 0.038 - 0.25 ± 20% 38 - 250 ± 10% 499a/01<br />
BS2. Merlin 0.04 ± 20% 40 ± 10% 499a/02<br />
Notes:<br />
1. LPCB Ref No. 499/01 covers non-printed material with a printed product marking band as required by LPS 1207: issue 2 Clause 4<br />
only.<br />
2. LPCB Ref. No. 499a/02 covers printed and non-printed material as sepcified with printed product marking band as required by LPS<br />
1207: Issue 2 Clause 4.<br />
Core Industrial Plastics Limited<br />
Unit 12, A1 Ferrybridge Business Park, Fishergate, Knottingley, West Yorkshire WF11 8NA, United Kingdom<br />
Tel: +44 (0)1977 676072 • Fax: +44 (0)1977 676069<br />
E-mail: sales@coreplastics.co.uk<br />
Certificate No: 803a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2<br />
Total Protection Board (Black) 2.3 ± 0.5 200 - 800 803a/02<br />
Total Protection Board (White) 2.3 ± 0.5 200 - 800 803a/03<br />
Note:<br />
1. LPCB Ref. No. 803a/02 & 803a/03 covers printed and non printed materials with a printed product marking band as required by LPS<br />
1207 Issue 2 clause 4.<br />
Don & Low Ltd, Nonwovens<br />
Glamis Road, Forfar, Angus DD8 1EY, United Kingdom<br />
Tel: +44 (0)1307 452600 • Fax: +44 (0)1307 452635<br />
E-mail: nonwovens@donlow.co.uk • Website: www.donlow.com<br />
Certificate No: 726a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness Weight Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Daltex Flame Retardant Spunbond (A100E5TFR) 0.5 nominal 100 ±6% 726a/01<br />
DS SMITH CORREX (Trading as a division of DS Smith Plastics Limited)<br />
Madleaze Industrial Estate, Bristol Road, Gloucester GL1 5SG, United Kingdom<br />
Tel: +44 (0)1452 316500 • Fax: +44 (0)1452 300436<br />
E-mail: sales@kayplast.com • Website: www.kaysersberg-plastics.com<br />
Certificate No: 227a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Correx Twinwall (black) 2.0 to 6.0 250 to 1500 227a/01<br />
Correx Twinwall (coloured & translucent) 2.0 to 6.0 250 to 1500 227a/02<br />
20 Nov 2011 163
PART 1: SECTION 5.1.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING<br />
Envirowrap Solutions Limited<br />
Registered Office:, Strangford House, Church Road, Ashford, Kent TN23 3QR, United Kingdom<br />
Tel: +44 (0)1233 860080 • Fax: +44 (0)1233 860090<br />
E-mail: enquiries@envirowrap.info • Website: www.envirowrap.info<br />
Certificate No: 691a to LPS 1207: Issue 2<br />
Envirowrap 250, 300, 350 & 400AFR-T D06-08<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Envirowrap 250AFR-T D06-08 0.25 ± 5% 253 ± 5% 691a/02<br />
Envirowrap 300AFR-T D06-08 0.30 ± 5% 305 ± 5%<br />
Envirowrap 350AFR-T D06-08 0.35 ± 5% 348 ± 5%<br />
Envirowrap 400AFR-T D06-08 0.40 ± 5% 399 ± 5%<br />
Note:<br />
1. LPCB Ref No. 691a/02 is available in white/light cream only and covers non printed product material with a printed product marking<br />
band as required by LPS 1207 Issue 2 Clause 4.<br />
Florprotec Limited<br />
Relay Park, Relay Drive, Tamworth B77 5PR, United Kingdom<br />
Tel: +44 (0)1827 831440 • Fax: +44 (0)1827 831441<br />
E-mail: sales@florprotec.co.uk • Website: www.floorprotection.co.uk<br />
Certificate No: 688a-x1 to LPS 1207: Issue 2.1<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2<br />
Florprotec T-Bord 2.0 - 4.5 250 - 1000 688a-x1/01<br />
Florprotec Envirobord 2.0 250 688a-x1/02<br />
Notes:<br />
1. LPCB Ref No. 688a-x1/01 is available in white only and covers printed and non printed material with a product marking band as<br />
required by LPS 1207: Issue 2 Clause 4.<br />
2. LPCB Ref No. 688a-x1/02 is availabe in black only and covers non printed material with a printed product marking band as required<br />
by LPS1207: Issue 2 Clause 4 only.<br />
Certificate No: 871a to LPS1207: Issue 2.1<br />
Product Name Thickness Weight<br />
Cert. No.<br />
(g/m²)<br />
CPP-FR 0.16 ± 10% 84 ± 5% 871a/01<br />
Notes<br />
1. LPCB Ref. No. 871a/01 covers white base sheet material, with or without additional printed areas, with a printed product marking band<br />
as required by LPS 1207 Issue 2 clause 4.<br />
Certificate No: 1030a to LPS 1207: Issue 2.1<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m²)<br />
TACBAC FR 0.065 nominal 83 ± 10% 1030a/01<br />
Notes<br />
1. LPCB Ref. No. 1030a/01 covers white (natural) base film material, printed and non-printed material with a printed product marking<br />
band as required by LPS 1207: Issue 2 Clause 4.<br />
2. LPCB ref. No. 1030a/01 TACBAC FR is a self-adhesive film.<br />
3. LPCB ref. No. 1030a/01 TACBAC FR the thickness quoted is the nominal film thickness and weight is quoted inclusive of the<br />
adhesive.<br />
164 20 Nov 2011
PART 1: SECTION 5.1.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING<br />
Gilray Plant Limited<br />
Cedar Depot, Church Manorway, Erith, Kent DA8 1DE, United Kingdom<br />
Tel: 01322 442006 • Fax: 01322 442009<br />
E-mail: sarah.wilson@gilray.co.uk • Website: www.gilray.co.uk<br />
Certificate No: 915a-x2 to LPS 1207 Issue 2.1<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2<br />
Fire-Retardant Multisheet 220 FR 0.7 ± 5% 220 +7/ - 5% 915a-x2/01<br />
Fire-Retardant Multisheet 170 FR 0.7 ± 5% 170 ± 10% 915a-x2/02<br />
Note:<br />
1. LPCB Ref No. 915a-x2/01 and 915a-x2/02 are available in white only and covers non printed material with a printed product marking<br />
band as required by LPS 1207 Issue 2 Clause 4 only.<br />
Goran Plastics<br />
Unit C, 5 Caxton Way, Watford Business Park, Watford, Herts WD18 8UA, United Kingdom<br />
Tel: +44 (0)1923 255700 • Fax: +44 (0)1923 255698<br />
E-mail: sales@goran.co.uk<br />
Certificate No: 688a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Polyflute Twinwall Polypropylene 2.0 - 4.5 250 - 1000 688a/01<br />
Polyflute Recycled FR 2.0 250 688a/02<br />
Notes:<br />
1. LPCB Ref No. 688a/01 is available in white only and covers printed and non printed material with a product marking band as required<br />
by LPS 1207: Issue 2 Clause 4.<br />
2. LPCB Ref. No. 688a/02 is available in black only and covers non printed material with a printed product making band as required by<br />
LPS 1207: Issue 2 Clause 4 only.<br />
Icopal Limited<br />
Barton Dock Road, Stretford, Manchester M32 0YL, United Kingdom<br />
Tel: +44 (0)161 865 4444 • Fax: +44 (0)161 865 8433<br />
E-mail: info@icopal.com • Website: www.icopal.co.uk<br />
Certificate No: 572c to LPS 1207: Issue 2<br />
Product Name Thickness (mm) Weight (g/m 2 ) Cert. No.<br />
Monarflex Stripe Firesmart 0.15 Nominal 210 ± 5% 540c/01<br />
Monarflex Super T Plus Firesmart 0.2 to 0.55 275 ± 5% 572c/01<br />
Notes:<br />
1. LPCB Ref. No. 572c/01 Monarflex Super T Plus Firesmart roll size <strong>2.2</strong>5m x 40m, 2m x 45m, 3m x 45m and 4m x 36m. Product<br />
produced at Monarflex s.r.o<br />
2. LPCB Ref. No. 572c/01 covers printed and non printed materials with a printed product marking band as required by LPS1207: Issue<br />
2 Clause 4.<br />
3. LPCB Ref. No. 540c/01 is available in white only and covers non printed materials with a printed product marking band as required by<br />
LPS1207: Issue 2 Clause 4 only.<br />
20 Nov 2011 165
PART 1: SECTION 5.1.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING<br />
Industrial Textiles & Plastics Ltd<br />
Stillington Road, Easingwold, York YO61 3FA, United Kingdom<br />
Tel: +44 (0)1347 825200 • Fax: +44 (0)1347 825222<br />
E-mail: info@itpltd.com • Website: www.itpltd.com<br />
Certificate No: 727a to LPS 1207: Issue 2<br />
Powerclad<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Powerclad SDFR 0.40 1 200 ±5% 727a/01<br />
Powerclad PMFR 0.40 1 240 ±5% 727a/02<br />
Notes:<br />
1) LPCB ref No. 727a/01 & 727a/02, the material thickness includes the reinforcing mesh.<br />
2) LPCB Ref. No’s. 727a/01 and 727a/02 covers printed and non printed Powerclad SDFR and PMFR materials with a printed product<br />
marking band as required by LPS 1207: Issue 2 Clause 4.<br />
Certificate No: 965a to LPS 1207 Issue 2.1<br />
Product Name Thickness (mm) Weight (g/m2) Cert. No.<br />
Powerclad PMFR 0.50 ±7% 230 ±7% 965a/01<br />
Notes:<br />
1. LPCB Ref. No. 965a/01 the material thickness includes the reinforcing mesh<br />
2. LPCB Ref. No. 965a/01 covers non printed material with a printed product marking band as required by LPS 1207: Issue 2 Clause 4.<br />
IPB N.V.<br />
Steenovenstraat 30, B-8790 Waregem, Belgium<br />
Tel: UK Sales +44 (0)800 834704 • Fax: +44 (0)800 834705<br />
Certificate No: 365a to LPS 1207: Issue 1<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Proplex 2.0 to 4.0 250 to 1000 365a/01<br />
Landskroon B.V.<br />
Tweelingenlaan 43, 7324 AP Apeldoorn, PO Box 195, 7300 AD Apeldoorn, The Netherlands<br />
Tel: +31(0) 555 999 555 • Fax: +31(0) 555 340 200<br />
E-mail: office@landskroon.nl • Website: www.landskroon.nl<br />
Certificate No: 915a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m²)<br />
Lankotex Scaffold TARP 220FR 0.7 ± 5% 220 +7/ - 5% 915a/01<br />
Lankotex Scaffold TARP 170FR 0.7 ± 5% 170 ± 10% 915a/02<br />
Note:<br />
1. LPCB Ref No. 915a/01 and 915a/02 are available in white only and cover non printed material with a printed product marking band as<br />
required by LPS 1207 Issue 2 Clause 4 only.<br />
166 20 Nov 2011
PART 1: SECTION 5.1.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING<br />
Monarflex<br />
Lyskaer 10,, DK-2730 Herlev, Copenhagen, Denmark<br />
Tel: +45 44 88 55 50 • Fax: +45 44 88 55 99<br />
E-mail: contact@monarflex.com • Website: www.special-fire.com<br />
Certificate No: 540a to LPS 1207: Issue 2<br />
Product Name<br />
Weight<br />
Cert. No.<br />
(g/m 2 )<br />
HD Barrier Film 206 to 252 540a/01<br />
MD Barrier Film 119 to 132<br />
Nields Plastic Company Limited<br />
Units 1 -2, Foley Works Estate, Hereford HR1 2SF, United Kingdom<br />
Tel: +44 (0)1432 268341 • Fax: +44 (0)1432 353247<br />
E-mail: sales@nields.co.uk<br />
Certificate No: 342a to LPS 1207: Issue 1<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Antimar 0.05 to 0.3 47 to 280±15% 342a/01<br />
Northern Ireland Plastics Limited<br />
39 Shrigley Road, Killyleagh, Co. Down, Northern Ireland BT30 9SR, United Kingdom<br />
Tel: +44 (0)2844 828753/4 • Fax: +44 (0)2844 828809<br />
E-mail: info@niplastics.co.uk<br />
Certificate No: 341a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Corriboard Twin Wall (white) 2.3 ± 0.5 200 to 800 341a/01<br />
Corriboard Twin Wall (black) 2.3 ± 0.5 200 to 800 341a/02<br />
Note:<br />
1. LPCB Ref. No. 341a/01 & 341a/02 covers printed and non printed materials with a printed product marking band as required by LPS<br />
1207 Issue 2 clause 4.<br />
Ockwells Limited<br />
Unit 6, Transigo, Gables Way, Thatcham, Berkshire RG19 4ZA, United Kingdom<br />
Tel: +44 (0)1635 876336 • Fax: +44 (0)1635 876338<br />
E-mail: sales@ockwell.co.uk • Website: www.ockwells.co.uk<br />
Certificate No: 726a-x1 to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m²)<br />
Floorshield FR 0.5 nominal 100 ±6% 726a-x1/01<br />
20 Nov 2011 167
PART 1: SECTION 5.1.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING<br />
Certificate No: 341a-x1 to LPS1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m²)<br />
Ockwells Twinshield (White) 2.3 ± 0.5 200 - 800 341a-x1/01<br />
Ockwells Twinshield (Black) 2.3 ± 0.5 200 - 800 341a-x1/02<br />
Note:<br />
1. LPCB Ref. No. 341a-x1/01 & 341a-x1/02 covers printed and non printed materials with a printed product marking band as required by<br />
LPS 1207 Issue 2 clause 4.<br />
Certificate No: 742a-x1 to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Ockwells Twinshield (Natural colour) 2.0 to 10.0 270 to 2000 ± 10% 742a-x1/01<br />
Certificate No: 688a-x2 to LPS1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m²)<br />
Ockwells Twinshield 2.0 - 4.5 250 - 1000 688a-x2/01<br />
Note:<br />
1. LPCB Ref No. 688a-x2/01 is available in white only and covers printed and non printed material with a product marking band as<br />
required by LPS 1207: Issue 2 Clause 4.<br />
Ondaplast SpA<br />
Via Crocetta, 3310, 47020 Longiano (FC), Italy<br />
Tel: +39 0547 56616 • Fax: +39 0547 54087<br />
E-mail: info@ondaplast.com • Website: www.ondaplast.com<br />
Certificate No: 742a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
RE-FLAM twin wall flame retardant sheet, natural colour 2.0 to 10.0 270 to 2000 ± 10% 742a/01<br />
Protec International Limited<br />
Construction House, Adlington Industrial Estate, Adlington, Cheshire SK10 4NL, United Kingdom<br />
Tel: +44 (0)1625 855666 • Fax: +44 (0)1625 855601<br />
E-mail: enquiries@protection.co.uk • Website: www.protection.co.uk<br />
Certificate No: 843a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2<br />
Proplex 2.0 to 4.0 250 to 1000 365a/01<br />
Promesh 1207 0.12 to 0.43 85 to 210 ± 5% 495a/01<br />
Protec Flame Retardant Barrier Sheet 0.45 170 495a/03<br />
CushionGard FR 4.0 nominal 155 ± 10% 843a/01<br />
Breathershield FR 0.5 nominal 100 ± 6% 843a/02<br />
FR Carpet Shield 0.065 ± 7% 80 ± 10% 894a/01<br />
FR Polythene - White 0.05 to 0.25 ± 5% 50.2 to 247.25 ± 5% 894a/02<br />
168 20 Nov 2011
PART 1: SECTION 5.1.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING<br />
Notes:<br />
1. LPCB Ref. No. 495a/03, the material thickness of the Protec Flame retardant barrier sheet includes the textured profile.<br />
2. LPCB Ref. No. 495a/02, 843a/01 & 894/01 covers printed and non-printed material with a printed product marking band as required<br />
by LPS 1207: Issue 2 Clause 4.<br />
3. LPCB Ref. No. 495a/01, 495a/03 & 894a/02 covers non printed material with a printed product marking band as required by LPS<br />
1207 Issue 2 Clause 4 only.<br />
4. LPCB Ref. No. 894a/01, the thickness quoted is the material thickness pre-embossed.<br />
5. LPCB Ref. No. 849a/01, the approval products are self-adhesive films.<br />
Protecta Screen Ltd<br />
5 Driberg Way, Braintree, Essex CM17 1NB, United Kingdom<br />
Tel: +44 (0)870 1218670 • Fax: +44 (0)870 1218680<br />
E-mail: sales@protectascreen.com • Website: www.protectascreen.com<br />
Certificate No: 688a-x3 to LPS1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m²)<br />
Protectaboard 2.0 - 3.0 270 - 450 688a-x3/01<br />
Sealed Air Limited<br />
Telford Way, Kettering, Northants NN16 8UN, United Kingdom<br />
Tel: +44 (0)1886 884 747 • Fax: +44 (0)1886 884 125<br />
E-mail: enquiries@special-fire.com • Website: www.special-fire.com<br />
Certificate No: 505a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Cushion Wrap 1207 approx 4.2 118 ± 2 505a/01<br />
Note:<br />
LPCB Ref No. 505a/01 covers printed and non-printed material with a printed product marking band as required by LPS 1207: Issue 2<br />
Clause 4.<br />
Sealed Air Limited<br />
Telford Way, Kettering, Northants NN16 8UN, United Kingdom<br />
Tel: 01536 315 700 • Fax: 01536 315 702<br />
E-mail: kettering.orders@sealedair.com • Website: www.sealedair.com<br />
Certificate No: 505b to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
g/m 2 )<br />
CMFR approx.4.2 60 ± 2 505b/02<br />
Note:<br />
1. LPCB Ref. No. 505b/02 is available in white only and covers non printed material with a printed product marking band as required by<br />
LPS 1207: Issue 2 Clause 4 only.<br />
20 Nov 2011 169
PART 1: SECTION 5.1.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING<br />
Solicom SA<br />
Rue de Drinklange 9, L-9911 Troisvierges, Luxembourg<br />
Tel: +352 26957256 • Fax: +352 26958056<br />
E-mail: info@solicompack.com • Website: www.verisafe.be<br />
Certificate No: 789a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Verisafe 200 (White) 0.20 ±5% 200 ±5% 789a/01<br />
Verisafe 400 (White) 0.40 ±5% 400 ±5% 789a/02<br />
Verisafe B1 280 (White) 0.28 +5/-10% 280 +5/-7% 789a/03<br />
Note:<br />
1. LPCB Ref. No. 789a/01, 789a/02 & 789a/03 are available in white only and cover non-printed Verisafe material as specified with a<br />
printed product marking band as required by LPS 1207: Issue 2 Clause 4 only.<br />
Sunjüt A.S.<br />
Yukari Dudullu, Organize San, Bölgesi I Cad. No. 29, Umraniye 34775, Istanbul, Turkey<br />
Tel: +44 (0)800 834704 • Fax: +44 (0)800 834705<br />
Certificate No: 495a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Promesh 1207 0.12 to 0.43 85 to 210 ± 5% 495a/01<br />
Protec Flame Retardant Barrier Sheet 0.45 170 495a/03<br />
Notes:<br />
1. LPCB Ref. No. 495a/03 The material thickness of the Protec flame retardant Barrier sheet includes the textured profile.<br />
2. LPCB Ref. No. 495a/01 & LPCB Ref. No. 495a/03 covers non printed material with a printed product marking band as required by<br />
LPS 1207: Issue 2 Clause 4 only.<br />
The Blinking Lamp Company Ltd<br />
Unit F, Motorway Distribution Centre, Avonmouth Way, Bristol BS11 9YT, United Kingdom<br />
Tel: +44(0) 1179 828180 • Fax: +44(0) 1179 382818<br />
E-mail: office@blinkinglamp.co.uk • Website: www.blinkinglamp.co.uk<br />
Certificate No: 915a-x1 to LPS 1207 : Issue 2<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m²)<br />
Tri-Flex HD FR 0.7 ± 5% 220 +7 / - 5% 915a-x1/01<br />
Tri-Flex FR 0.7 ± 5% 170 ± 10% 915a-x1/02<br />
Note:<br />
1. LPCB Ref No. 915a-x1/01 and 915a-x1/02 are available in white only and covers non printed material with a printed product marking<br />
band as required by LPS 1207 Issue 2 Clause 4 only.<br />
170 20 Nov 2011
PART 1: SECTION 5.1.1<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING<br />
Total Polyfilm Limited<br />
Armytage Road, The Industrial Estate, Brighouse, West Yorkshire HD6 1PT, United Kingdom<br />
Tel: +44 (0)1484 714313 • Fax: +44 (0)1484 720452<br />
Certificate No: 527a to LPS 1207: Issue 2<br />
Frapol Sheeting<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Frapol HD 0.200 to 0.300 ± 10% 186 to 279 ± 10% 527a/01<br />
Frapol LD 0.50 to 0.99 ± 10% 46 to 92 ± 10%<br />
Frapol MD 0.100 to 0.199 ± 10% 93 to 185 ± 10%<br />
Note:<br />
1. LPCB Ref No 527a/01 covers printed and non printed materials with a printed product marking band as required by LPS1207: Issue 2<br />
Clause 4. The approval covers natural (white) and pigmented film.<br />
Twinplast Limited<br />
Unit 2, Greycaine Road, Watford, Hertfordshire WD24 7GP, United Kingdom<br />
Tel: +44 (0)1923 230191/817761 • Fax: +44 (0)1923 817756<br />
E-mail: sales@twinplast.co.uk • Website: www.twinplast.co.uk<br />
Certificate No: 375a to LPS 1207: Issue 2<br />
Product Name<br />
Thickness Weight Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Twinplast / Antinox FR Protection Board (white) 2.0 to 6.0 250 to 1400 375a/01<br />
2.0 200 to 250 375a/02<br />
Twinplast / Antinox FR Protection Board (white, black or coloured) 2.0 to 4.0 250 to 1000 375a/03<br />
Twinplast / Antinox Antistatic FR Protection Board (white) 4.0 700 375a/04<br />
Twinplast / Antinox Recycled FR Protection Board (black) 2.0 250 375a/05<br />
Note:<br />
1. LPCB Ref Nos. 375a/01, 375a/02, 375a/03, 375a/04 and 375a/05 covers printed and non printed materials with a printed product<br />
marking band as required by LPS1207: Issue 2 Clause 4.<br />
Univar Speciality Consumables<br />
Armstrong Road, The Royal Arsenal, London SE18 6RS, United Kingdom<br />
Tel: +44 (0)20 8312 7200 • Fax: +44 (0)20 8312 7250<br />
E-mail: uscmsales@univareurope.com • Website: www.univareurope.com<br />
Certificate No: 709a to LPS 1207: Issue 2<br />
Product Name Thickness (mm) Weight (g/m 2 ) Cert. No.<br />
MP70TRA twin wall fluted sheet 2.0 250 ± 10 709a/01<br />
MP70BLA twin wall fluted sheet 2.0 250 ± 10 709a/02<br />
MP70WHI twin wall fluted sheet 2.0 250 ± 10 709a/03<br />
Note:<br />
1. LPCB Ref. No. 709a/01, 709a/02 & 709a/03 covers printed and non printed materials with a printed product marking band as required<br />
by LPS1207: Issue 2 Clause 4.<br />
20 Nov 2011 171
PART 1: SECTION 5.1.2<br />
LPS 1207 PROTECTIVE COVERING MATERIALS - PRE-FORMED<br />
Ockwells Limited<br />
Unit 6, Transigo, Gables Way, Thatcham, Berkshire RG19 4ZA, United Kingdom<br />
Tel: +44 (0)1635 876336 • Fax: +44 (0)1635 876338<br />
E-mail: sales@ockwell.co.uk • Website: www.ockwells.co.uk<br />
Certificate No: 898a to LPS1207: Issue 2<br />
Product Name<br />
Wall<br />
Thickness<br />
(mm)<br />
Size Range<br />
(mm)<br />
Density<br />
(g/m³)<br />
Cert. No.<br />
Ockwells 048 Universal Foam Protector - Flame Retardant 13 ± 1 O-Profile 48 36 ± 3 898a/01<br />
Ockwells114 Universal Foam Protector - Flame Retardant 13 ±1 O-Profile 114 36 ± 3<br />
Ockwells 90/110 Universal Foam Protector - Flame Retardant 13 ± 1 U-Profile 90/110 36 ± 3 898a/02<br />
Note:<br />
1. LPCB Ref. No. 898a/01 & 898a/02 is available in Orange only and covers non printed material with a printed product marking band as<br />
required by LPS 1207: Issue 2 Clause 4 only.<br />
Protec International Limited<br />
Construction House, Adlington Industrial Estate, Adlington, Cheshire SK10 4NL, United Kingdom<br />
Tel: +44 (0)1625 855666 • Fax: +44 (0)1625 855601<br />
E-mail: enquiries@protection.co.uk • Website: www.protection.co.uk<br />
Certificate No: 843b to LPS 1207: Issue 2<br />
Product Name<br />
Wall Thickness<br />
Size Range<br />
Density 3 ) Cert. No.<br />
(mm)<br />
(mm)<br />
Protective Foam Tubing (Red) 13 -1/+0.5 Internal dia. 15 to 114 30±5 634a/01<br />
172 20 Nov 2011
PART 1: SECTION 5.2<br />
LPS 1215 SCAFFOLD CLADDING MATERIALS<br />
Scaffold cladding materials such as sheeting and netting are often used externally during construction,<br />
refurbishment or demolition of buildings to provide protection. Historically, there have been a number of<br />
significant losses associated with fires involving scaffolding. Scaffold cladding materials should not add to the<br />
fire risk if they comply with LPS 1215 Requirements for the LPCB approval and listing of scaffold cladding<br />
materials.<br />
Note: LPS 1215:Issue 3 does not cover other features required of scaffold materials, such as resistance to<br />
wind, rain penetration, resistance to tearing or impact damage.<br />
Envirowrap Solutions Limited<br />
Registered Office:, Strangford House, Church Road, Ashford, Kent TN23 3QR, United Kingdom<br />
Tel: +44 (0)1233 860080 • Fax: +44 (0)1233 860090<br />
E-mail: enquiries@envirowrap.info • Website: www.envirowrap.info<br />
Certificate No: 691b to LPS 1215: Issue 3<br />
Envirowrap 250, 300, 350 & 400AFR-T D06-08<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Envirowrap 250AFR-T D06-08 0.25 ± 5% 253 ± 5% 691b/02<br />
Envirowrap 300AFR-T D06-08 0.30 ± 5% 305 ± 5%<br />
Envirowrap 350AFR-T D06-08 0.35 ± 5% 348 ± 5%<br />
Envirowrap 400AFR-T D06-08 0.40 ± 5% 399 ± 5%<br />
Note:<br />
1. LPCB Ref No. 691b/02 is available in white/light cream only and covers non printed product material with a printed product marking<br />
band as required by LPS 1215 Issue 3 Clause 4.<br />
Gilray Plant Limited<br />
Cedar Depot, Church Manorway, Erith, Kent DA8 1DE, United Kingdom<br />
Tel: 01322 442006 • Fax: 01322 442009<br />
E-mail: sarah.wilson@gilray.co.uk • Website: www.gilray.co.uk<br />
Certificate No: 915b-x2 to LPS 1215 Issue 3<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m²)<br />
Fire-Retardant Multisheet 220 FR 0.7 ± 5% 220 +7/ - 5% 915b-x2/01<br />
Fire-Retardant Multisheet 170 FR 0.7 ± 5% 170 ± 10%<br />
225 ± 10% (incl. printing)<br />
915b-x2/02<br />
Notes:<br />
1. LPCB Ref No. 915b-x2/01 is available in white only and covers non printed material with a printed product marking band as required<br />
by LPS 1215 Issue 3 Clause 4 only.<br />
2. LPCB Ref No. 915b-x2/02 is available in white only and covers printed and non printed material with a printed product marking band<br />
as required by LPS 1215 Issue 3 Clause 4.<br />
Certificate No: 1061a-x2 to LPS 1215: Issue 3<br />
Flame Retardant Debris Netting<br />
Product Name Thickness (mm Weight (g/m²) Cert. No.<br />
Flame Retardant Debris Netting 0.75 ± 10% 85 ± 15% 1061a-x2/01<br />
Notes:<br />
1. LPCB Ref No. 1061a-x2/01 is available in Blue, White, Black, Green, Red, Yellow and Orange and is non-printed material as<br />
specified with a printed product marking band as required by LPS1215 Issue 3 clause 4 only.<br />
20 Nov 2011 173
PART 1: SECTION 5.2<br />
LPS 1215 SCAFFOLD CLADDING MATERIALS<br />
Icopal Limited<br />
Barton Dock Road, Stretford, Manchester M32 0YL, United Kingdom<br />
Tel: +44 (0)161 865 4444 • Fax: +44 (0)161 865 8433<br />
E-mail: info@icopal.com • Website: www.icopal.co.uk<br />
Certificate No: 572d to LPS 1215: Issue 3<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Monarflex Stripe Firesmart 0.15 Nominal 210 ± 5% 540d/01<br />
Monarflex Super T Plus Firesmart 0.2 to 0.55 275 ± 5% 572d/01<br />
Monarflex Temporary Roof Cover Flamesafe 0.2 to 0.55 233 ± 10% 572d/02<br />
Notes:<br />
1. LPCB Ref. No. 572d/01 & 572d/02 Monarflex Super T Plus Firesmart roll size <strong>2.2</strong>5m x 40m, 2m x 45m, 3m x 45m and 4m x 36m.<br />
Monarflex Temporary Roof Cover Flamesafe roll size 23.35m x 50m and 3.35m x 30m. Products produced at Monarflex s.r.o<br />
2. LPCB Ref. No. 572d/01 covers printed and non printed materials with a printed product marking band as required by LPS1215: Issue<br />
3 Clause 4.<br />
3. LPCB Ref. No. 540d/01 is available in white only and covers non printed materials with a printed product marking band as required by<br />
LPS1215: Issue 3 Clause 4 only.<br />
Industrial Textiles & Plastics Ltd<br />
Stillington Road, Easingwold, York YO61 3FA, United Kingdom<br />
Tel: +44 (0)1347 825200 • Fax: +44 (0)1347 825222<br />
E-mail: info@itpltd.com • Website: www.powerclad.com<br />
Certificate No: 727b to LPS 1215: Issue 3<br />
Powerclad<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Powerclad SDFR 0.40 200 ±5% 727b/01<br />
Powerclad PMFR 0.40 240 ±5% 727b/02<br />
Notes:<br />
1. LPCB Ref. No. 727b/01 & 727b/02, the material thickness includes the reinforcing mesh.<br />
2. LPCB Ref. No. 727b/01 and 727b/02 covers printed and non printed Powerclad SDFR and PMFR material with a printed product<br />
marking band as required by LPS 1215: Issue 3 Clause 4.<br />
Certificate No: 965b to LPS1215 Issue 3.1<br />
Product Name Thickness (mm) Weight (g/m2) Cert. No.<br />
Powerclad PMFR 0.50 ±7% 230 ±7% 965b/01<br />
Powerclad SDFR 0.20 ±5% 180 ±9% 965b/02<br />
Powerclad RSFR 0.40 ±10% 300 ±10% 965b/03<br />
Notes:<br />
1. LPCB Ref No. 965b/01 the material thickness includes the reinforcing mesh.<br />
2. LPCB Ref. No. 965b/01 covers printed and non printed material with a printed product marking band as required by LPS 1215: Issue<br />
3 Clause 4.<br />
3. LPCB Ref. No. 965b/02 & 965b/03 covers non printed material with a printed product marking band as required by LPS 1215: Issue 3<br />
Clause 4.<br />
174 20 Nov 2011
PART 1: SECTION 5.2<br />
LPS 1215 SCAFFOLD CLADDING MATERIALS<br />
Landskroon B.V.<br />
Tweelingenlaan 43, 7324 AP Apeldoorn, PO Box 195, 7300 AD Apeldoorn, The Netherlands<br />
Tel: +31(0) 555 999 555 • Fax: +31(0) 555 340 200<br />
E-mail: office@landskroon.nl • Website: www.landskroon.nl<br />
Certificate No: 915b to LPS1215: Issue 3<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m²)<br />
Lankotex Scaffold TARP 220FR 0.7 ± 5% 220 +7 /- 5% 915b/01<br />
Lankotex Scaffold TARP 170FR 0.7 ± 5% 170 ± 10%<br />
225 ± 10% (incl. printing)<br />
915b/02<br />
Notes:<br />
1. LPCB Ref No. 915b/01 is available in white only and covers non printed material with a printed product marking band as required by<br />
LPS 1215 Issue 3 Clause 4 only.<br />
2. LPCB Ref No. 915b/02 is available in white only and covers printed and non printed material with a printed product marking band as<br />
required by LPS 1215 Issue 3 Clause 4.<br />
Protec International Limited<br />
Construction House, Adlington Industrial Estate, Adlington, Cheshire SK10 4NL, United Kingdom<br />
Tel: +44 (0)1625 855666 • Fax: +44 (0)1625 855601<br />
E-mail: enquiries@protection.co.uk • Website: www.protection.co.uk<br />
Certificate No: 843c to LPS 1215: Issue 3<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2<br />
Proscaff Premium FR 0.60 250 495b/01<br />
Scaffnet FR (white) 0.30 (single yarn) 65±5% 495b/02<br />
Notes:<br />
1. LPCB Ref. 495b/01 Covers printed and non printed materials with a printed product marking band as required by LPS 1215: Issue 3<br />
Clause 4.<br />
Solicom SA<br />
Rue de Drinklange 9, L-9911 Troisvierges, Luxembourg<br />
Tel: +352 26957256 • Fax: +352 26958056<br />
E-mail: info@solicompack.com • Website: www.verisafe.be<br />
Certificate No: 789b to LPS 1215: Issue 3<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Verisafe 320 (White) 0.32 ±5% 320 ±5% 789b/01<br />
Verisafe 400 (White) 0.40 ±5% 400 ±5% 789b/02<br />
Verisafe B1 280 (White) 0.28 +5/-10% 280 +5/-7% 789b/03<br />
Note:<br />
1. LPCB Ref. No. 789b/01, 789b/02 & 789b/03 are available in white only and cover non-printed Verisafe material as specified with a<br />
printed product marking band as required by LPS 1215: Issue 3 Clause 4 only.<br />
20 Nov 2011 175
PART 1: SECTION 5.2<br />
LPS 1215 SCAFFOLD CLADDING MATERIALS<br />
Sunjüt A.S.<br />
Yukari Dudullu, Organize San, Bölgesi I Cad. No. 29, Umraniye 34775, Istanbul, Turkey<br />
Tel: +44 (0)800 834704 • Fax: +44 (0)800 834705<br />
Certificate No: 495b to LPS 1215: Issue 3<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m 2 )<br />
Proscaff Premium FR 0.60 250 495b/01<br />
Scaffnet FR (white) 0.30 (single yarn) 65 ± 5% 495b/02<br />
Note:<br />
1 LPBC Ref. 4965b/01 Covers printed and non printed materials with a printed product marking band as required by LPS1215: Issue 3<br />
Clause 4<br />
The Blinking Lamp Company Ltd<br />
Unit F, Motorway Distribution Centre, Avonmouth Way, Bristol BS11 9YT, United Kingdom<br />
Tel: +44(0) 1179 828180 • Fax: +44(0) 1179 382818<br />
E-mail: office@blinkinglamp.co.uk • Website: www.blinkinglamp.co.uk<br />
Certificate No: 915b-x1 to LPS 1215: Issue 3<br />
Product Name<br />
Thickness<br />
Weight<br />
Cert. No.<br />
(mm)<br />
(g/m²)<br />
Tri-Flex HD FR 0.7 ± 5% 220 +7/ - 5% 915b-x1/01<br />
Tri-Flex FR 0.7 ± 5% 170 ± 10%<br />
225 ± 10% (incl. printing)<br />
915b-x1/02<br />
Notes:<br />
1. LPCB Ref No. 915b-x1/01 is available in white only and covers non printed material with a printed product marking band as required<br />
by LPS 1215 Issue 3 Clause 4 only.<br />
2. LPCB Ref No. 915b-x1/02 is available in white only and covers printed and non printed material with a printed product marking band<br />
as required by LPS 1215 Issue 3 Clause 4.<br />
Certificate No: 1061a-x1 to LPS 1215: Issue 3<br />
Product Name Thickness (mm) Weight (g/m²) Cert. No.<br />
Tri-Net FR 0.75 ± 10% 85 ± 15% 1061a-x1/01<br />
Notes:<br />
1. LPCB ref No. 1061a-x1/01 is available in Blue, White, Black Green, Red, Yellow and Orange and is non-printed material as specified<br />
with a printed marking band as required by LPS1215 Issue 3 clause 4 only.<br />
176 20 Nov 2011
PART 1: SECTION 6<br />
CAVITY FIRE BARRIERS<br />
The materials listed in this <strong>section</strong> can be used to sub-divide such voids as service shafts, roof and floor<br />
spaces and restrict the spread of fire. In the absence of a specific test standard for cavity barriers these<br />
products meet the performance requirements of BS 476:Part 22:1987 Methods for determination of the fire<br />
resistance of non-loadbearing elements of construction or BS EN 1364-1Fire resistance tests for nonloadbearing<br />
elements, walls or 1364-2 Fire resistance tests for non-loadbearing elements, ceilings as set<br />
down in Approved Document B. The LPC Design Guide for the Fire Protection of Buildings: 2000 covers the<br />
design issues in Section 4.5.<br />
The assessment methodology used in LPS 1208 also applies to the performance assessment for these<br />
products.<br />
Culimeta-Saveguard Limited<br />
Tame Valley Mill, Wainwright Street, Dukinfield, Cheshire SK16 5NB, United Kingdom<br />
Tel: +44 (0)161 344 2484 • Fax: +44 (0)161 344 2486<br />
E-mail: sales@saveguard.com<br />
Certificate No: 552a to LPS 1208: Issue 2<br />
Product Name<br />
Specification<br />
(m)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Cert. No.<br />
FireHalt Gold 3.0 long x 1.2 wide 132 38 552a/01<br />
Notes:<br />
1. The barriers can only be installed vertically.<br />
2. Joints between individual runs in a barrier must be fixed using 12mm staples at 50mm centres.<br />
Rockwool Limited<br />
Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom<br />
Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302<br />
E-mail: info@rockwool.co.uk • Website: www.rockwool.co.uk<br />
Certificate No: 022c to LPS 1208: Issue 2<br />
Product Name Product Specification Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Rockwool Firepro Fire ½ hour Fire 1 layer 60mm Fire Barrier foil faced<br />
Barrier System Barrier<br />
overlapped joints<br />
½ hour Cavity<br />
Barrier<br />
1 hour Fire 2 layers 50mm Fire Barrier staggered<br />
Barrier<br />
vertical joints<br />
1½ Hour Fire 2 layers 50mm Fire Barrier<br />
Barrier<br />
2 hour Fire<br />
Barrier<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grading<br />
Cert.<br />
No.<br />
60 30 FR30 022c/01<br />
1 layer 50mm thick 60 15 FR15<br />
staggered vertical joints<br />
2 layers 60mm Fire Barrier foil faced<br />
separated by 40mm air gap<br />
60 60 FR60<br />
90 90 FR90<br />
120 120 FR120<br />
Notes:<br />
1. This product is supplied in 1m widths, with a length of 4m for 50mm thick Fire Barrier and 3.5m for 60mm thick Fire Barrier.<br />
2. The maximum allowable drop is 6m without a support frame. Where the additional <strong>section</strong> is joined the barrier should be overlapped<br />
by at least 100mm and stitched.<br />
3. Refer to manufacturer's technical literature for fixing details.<br />
20 Nov 2011 177
PART 1: SECTION 6<br />
CAVITY FIRE BARRIERS<br />
Certificate No: 022c to LPS1208: Issue 2<br />
Rockwool Firepro Fire Barrier Slab<br />
Product Name<br />
Cavity<br />
Width<br />
(mm)<br />
Slab<br />
Size<br />
(mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
Grade<br />
Cert. No.<br />
Rockwool Firepro Fire Barrier Slab Up to 1000 1000 x 600 x 100 240 60 FR60 022c/02<br />
Notes:<br />
1. Where the slab is penetrated by services, the fire resistance is reduced to 90 minutes integrity and 60 minutes insulation. The size of<br />
the penetrations should not exceed steel pipes having a diameter of 33.5mm external diameter, or steel cable trays 305mm wide x<br />
50mm high x 0.9mm thick. Rockwool Acoustic and Fire Sealant should also be applied to all butt edges to form a tight bond when a<br />
penetration passes through the slab. The Acoustic and Fire Sealant should be tapered from 16mm deep at the face of the slab to<br />
nothing at a distance of 40mm on both faces.<br />
2. Refer to manufacturer's technical literature for fixing details.<br />
178 20 Nov 2011
PART 1: SECTION 7<br />
LPS 1195 TEMPORARY BUILDINGS FOR USE ON CONSTRUCTION SITES<br />
Temporary buildings are widely used on construction sites as site offices, canteens and rest areas etc. On some<br />
large construction sites the number of temporary buildings can form a virtual village; a fire starting in one of these<br />
temporary buildings could be catastrophic if the fire were to break out and spread to other temporary buildings or<br />
to the building under construction.<br />
LPS 1195:Part 1 Specification for Testing of Temporary Buildings for Use on Construction Sites specifies the test<br />
and performance requirements for temporary buildings for use on construction sites at locations less than 6m<br />
from buildings under construction/refurbishment. The basic objective is to prevent a fire which has started in a<br />
temporary building from spreading to adjacent combustible materials, other temporary buildings or to the building<br />
under construction. A temporary building tested and approved by LPCB to this standard can be regarded as<br />
meeting the appropriate requirements of “The Joint Code of Practice on the Protection from Fire of Construction<br />
Sites and Buildings Undergoing Renovation”.<br />
McAvoy Group Limited<br />
2 Ferguson Road, Knockmore Hill Industrial Estate, Lisburn, Co Antrim BT28 2FW, United Kingdom<br />
Tel: +44 (0)870 2408987 • Fax: +44 (0)28 8774 88495<br />
E-mail: sales@mcavoygroup.co.uk • Website: www.mcavoygroup.com<br />
Certificate No: 728a to LPS 1195: Part 1: Issue 4<br />
Product Name<br />
SafeSpace Fire rated office<br />
Maximum<br />
Size (mm) &<br />
Configurations<br />
9750(L) x<br />
3040(W) x<br />
3040(H)<br />
See Note 1<br />
Maximum<br />
Supporting Load<br />
(note 4)<br />
Integrity<br />
Performance<br />
Insulation<br />
Performance<br />
Irradiance<br />
Performance<br />
Cert. No.<br />
8.5 tonne 30 minutes 30 minutes 0.005<br />
kW/m 2 728a/01<br />
Notes:<br />
1. The certification applies to unit configurations as follows;<br />
12FT x 10FT Fire rated office, drawing reference FRO-1210-0-011<br />
16FT x 10FT Fire rated office, drawing reference FRO-1610-0-021<br />
20FT x 10FT Fire rated office, drawing reference FRO-2010-0-021<br />
24FT x 10FT Fire rated office, drawing reference FRO-2410-0-021<br />
30FT x 10FT Fire rated office, drawing reference AVO-3010-0-031-08<br />
32FT x 10FT Fire rated office, drawing reference FRO-3210-0-031<br />
Including up to 3 off 1067 x 940mm fire rated timber frame windows with external steel security shutters (Note 2) and, 1 off 762 x<br />
1981mm fire rated timber door with external steel security door (Note 3).<br />
2. Test conducted with steel security shutters in the open position.<br />
3. Test conducted with the steel security door in the closed position.<br />
4. Imposed load applied evenly distributed on a floor <strong>section</strong> located on the top of the 4 structural corner posts.<br />
20 Nov 2011 179
PART 1: SECTION 8<br />
PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS<br />
The products listed in this <strong>section</strong> have been assessed for use in rail transport applications in which the<br />
means of escape from a fire is limited as a result of:<br />
<br />
<br />
<br />
Difficulties in escaping from moving vehicles.<br />
The location of the fire (sub surface tunnels, viaducts, termini).<br />
Restricted egress from tunnels and sub surface termini.<br />
Under such circumstances, it is essential that the materials used in the construction and furnishings of<br />
vehicles and sub surface constructions have the appropriate fire performance in terms of fire resistance and<br />
reaction to fire, including spread of flame, smoke and toxic fume emission.<br />
This scheme provides independent third <strong>part</strong>y approval for fire performance of products which have been<br />
tested and, where appropriate, classified in accordance with standards and codes of practice recognised by<br />
the transport industry or produced by the relevant transport bodies such as London Underground Limited<br />
(LUL), International Maritime Organisation (IMO) etc.<br />
Products gaining LPCB approval under this scheme are primarily for use in transport applications such as<br />
rolling stock, shipping, motor vehicles and within transport infrastructure such as underground tunnels and<br />
transport termini.<br />
MCT Brattberg AB<br />
SE 37192 Karlskrona, Sweden<br />
Tel: +46 (0) 455 451 60 • Fax: +46 (0) 455 451 28<br />
E-mail: info@mctbrattberg.com • Website: www.mctbrattberg.com<br />
UK Office:<br />
MCT Brattberg Ltd, Commerce Street, Carrs Industrial Estate, Haslingden BB4 5JT, United Kingdom<br />
Tel: +44 (0)1706 244890 • Fax: +44 (0)1706 244891<br />
E-mail: info@mctbrattberg.co.uk • Website: www.mctbrattberg.co.uk<br />
Certificate No: 628a to LPS 1132: Issue 4<br />
Product Name Use Element of<br />
Construction<br />
RGB 2, 4 , 6, 8 & RGB 180, 240 & 360 Cables Concrete or masonry<br />
Floor<br />
Steel pipe Concrete or masonry<br />
Floor<br />
Cables Concrete or masonry<br />
Wall<br />
Steel pipes Concrete or masonry<br />
Wall<br />
RGBO 2, 4 , 6, 8 & RGBO 180, 240 & 360 Cables Concrete or masonry<br />
Floor<br />
Steel pipes Concrete or masonry<br />
Floor<br />
Cables Concrete or masonry<br />
Wall<br />
Steel pipes Concrete or masonry<br />
Wall<br />
RGP 50, 70, 100, 150, 200 & 300 Cables Concrete or masonry<br />
Floor<br />
Steel pipes Concrete or masonry<br />
Floor<br />
Cables Concrete or masonry<br />
Wall<br />
Steel pipes Concrete or masonry<br />
Wall<br />
Fire Resistance<br />
(min)<br />
Integrity<br />
Fire Resistance<br />
(min)<br />
Insulation<br />
Cert. No.<br />
240 120 628a/01<br />
240 60<br />
240 60<br />
240 60<br />
240 120 628a/02<br />
240 60<br />
240 60<br />
240 60<br />
360 120 628a/03<br />
240 60<br />
360 120<br />
240 60<br />
180 20 Nov 2011
PART 1: SECTION 8<br />
PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS<br />
Product Name Use Element of<br />
Construction<br />
RGPO 50, 70, 100, 150, 200 & 300 Cables Concrete or masonry<br />
Floor<br />
Steel pipes Concrete or masonry<br />
Floor<br />
Cables Concrete or masonry<br />
Wall<br />
Steel pipes Concrete or masonry<br />
Wall<br />
Fire Resistance<br />
(min)<br />
Integrity<br />
Fire Resistance<br />
(min)<br />
Insulation<br />
Cert. No.<br />
360 120 628a/04<br />
240 60<br />
360 120<br />
240 60<br />
Note:<br />
1. Please refer to manufacture’s product data for maximum aperture sizes and installation details.<br />
Rockwool Limited<br />
Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom<br />
Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302<br />
E-mail: info@rockwool.co.uk • Website: www.rockwool.co.uk<br />
Certificate No: 022e to EN 13501-1: 2002<br />
Product Name<br />
Thickness Test/Assessment Classification Cert. No.<br />
(mm)<br />
Standard<br />
Cladding Roll - Unfaced 60 - 180 EN 13501-1:2002 A1 022e/01<br />
Cladding Roll - Aluminum foil faced 60 - 180 EN 13501-1:2002 A1<br />
Cladding Roll - White tissue faced 60 - 180 EN 13501-1:2002 A1<br />
Flexi Batts - Unfaced 50 - 150 EN 13501-1:2002 A1 022e/04<br />
Certificate No: 022f to BS 476: Part 24: 1987<br />
FirePro Fire Duct Systems<br />
Product Name Duct Type Condition Maximum Duct<br />
Size<br />
(ht x wt)<br />
(mm)<br />
FirePro Fire Duct<br />
Systems<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Cert.<br />
No.<br />
1000 x 1000 25 30 30 022f/01<br />
1000 x 1000 30 60 60<br />
1500 x 1500 50 90 90<br />
1500 x 1500 70 120 120<br />
1525 dia. 25 30 30<br />
1525 dia. 30 60 60<br />
1525 dia. 50 90 90<br />
1525 dia. 70 120 120<br />
1000 x 1000 25 30 30<br />
20 Nov 2011 181
PART 1: SECTION 8<br />
PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS<br />
Product Name Duct Type Condition Maximum Duct<br />
Size<br />
(ht x wt)<br />
(mm)<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
1500 x 1500 40 60 60<br />
1200 x 1200 70 90 90<br />
1000 x 1000 90 120 120<br />
1525 dia. 25 30 30<br />
1525 dia. 40 60 60<br />
1525 dia. 70 90 90<br />
1525 dia. 90 120 120<br />
Fire Inside 1000 x 1000 25 30 30<br />
Fire Inside 1000 x 1000 30 60 60<br />
Fire Inside 1500 x 1500 50 90 90<br />
Fire Inside 1500 x 1500 70 120 120<br />
Fire Inside 1525 dia. 25 30 30<br />
Fire Inside 1525 dia. 30 60 60<br />
Fire Inside 1525 dia. 50 90 90<br />
Fire Inside 1525 dia. 70 120 120<br />
Fire Inside 1000 x 1000 25 30 30<br />
Fire Inside 1500 x 1500 40 60 60<br />
Fire Inside 1200 x 1200 70 90 90<br />
Fire Inside 1000 x 1000 90 120 120<br />
Fire Inside 1525 dia. 25 30 30<br />
Fire Inside 1525 dia. 40 60 60<br />
Fire Inside 1525 dia. 70 90 90<br />
Fire Inside 1525 dia. 90 120 120<br />
Cert.<br />
No.<br />
182 20 Nov 2011
PART 1: SECTION 8<br />
PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS<br />
Product Name Duct Type Condition Maximum Duct<br />
Size<br />
(ht x wt)<br />
(mm)<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
1000 x 1000 25 30 30<br />
1000 x 1000 30 60 60<br />
1500 x 1500 50 90 90<br />
1500 x 1500 70 120 120<br />
1525 dia. 25 30 30<br />
1525 dia. 30 60 60<br />
1525 dia. 50 90 90<br />
1525 dia. 70 120 120<br />
1000 x 1000 25 30 30<br />
1500 x 1500 40 60 60<br />
1200 x 1200 70 90 90<br />
1000 x 1000 90 120 120<br />
1525 dia. 25 30 30<br />
1525 dia. 40 60 60<br />
1525 dia. 70 90 90<br />
1525 dia. 90 120 120<br />
Fire Inside 1000 x 1000 25 30 30<br />
Cert.<br />
No.<br />
20 Nov 2011 183
PART 1: SECTION 8<br />
PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS<br />
Product Name Duct Type Condition Maximum Duct<br />
Size<br />
(ht x wt)<br />
(mm)<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
vertical<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Smoke<br />
Outlet<br />
horizontal<br />
orientation<br />
Kitchen<br />
Extract<br />
Kitchen<br />
Extract<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Fire Inside 1000 x 1000 30 60 60<br />
Fire Inside 1500 x 1500 50 90 90<br />
Fire Inside 1500 x 1500 70 120 120<br />
Fire Inside 1525 dia. 25 30 30<br />
Fire Inside 1525 dia. 30 60 60<br />
Fire Inside 1525 dia. 50 90 90<br />
Fire Inside 1525 dia. 70 120 120<br />
Fire Inside 1000 x 1000 25 30 30<br />
Fire Inside 1500 x 1500 40 60 60<br />
Fire Inside 1200 x 1200 70 90 90<br />
Fire Inside 1000 x 1000 90 120 120<br />
Fire Inside 1525 dia. 25 30 30<br />
Fire Inside 1525 dia. 40 60 60<br />
Fire Inside 1525 dia. 70 90 90<br />
Fire Inside 1525 dia. 90 120 120<br />
Fire<br />
Outside<br />
Fire<br />
Outside<br />
1500 x 1500 40 30 30<br />
1000 x 1000 90 60 60<br />
Cert.<br />
No.<br />
Certificate No: 22b to LPS 1132: Issue 4<br />
184 20 Nov 2011
PART 1: SECTION 8<br />
PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS<br />
FirePro TM Acoustic Intumescent sealant<br />
Product<br />
Name<br />
FirePro <br />
Acoustic<br />
Intumescent<br />
Sealant<br />
Element of<br />
Construction<br />
Orientation<br />
Element of<br />
Construction<br />
Thickness<br />
(mm)<br />
Element of<br />
Construction<br />
Material<br />
Maximum<br />
Joint<br />
Width<br />
(mm)<br />
Configeration:<br />
Fire Side<br />
Depth of<br />
Sealant (mm)<br />
Configeration:<br />
Configeration:<br />
Backing<br />
Material<br />
floor 230 AC/AC 50 25 Ethafoam<br />
50mm<br />
floor 230 Softwood/AC 25 12 Ethafoam<br />
30mm<br />
floor 230 Hardwood/AC 50 25 Ethafoam<br />
50mm<br />
floor 230 Steel/AC 50 25 Ethafoam<br />
50mm<br />
floor 250 AC/AC 30 15 Ethafoam<br />
40mm<br />
floor 250 AC/AC 15 10 Ethafoam<br />
25mm<br />
floor 250 AC/AC 20 Polyethylene<br />
20mm<br />
floor 250 AC/AC 50 Polyethylene<br />
50 x 25mm<br />
floor 250 AC/AC 10 Polyethylene<br />
0mm<br />
floor 250 AC/AC 25 Polyethylene<br />
25mm<br />
floor 250 Hardwood/AC 15 10 Ethafoam<br />
15mm<br />
floor 250 Steel/AC 15 10 Ethafoam<br />
25mm<br />
wall 150 AC/AC 30 30 Polyethylene<br />
30 x 15<br />
wall 150 AC/AC 15 15 Polyethylene<br />
15 x 15<br />
wall 150 AC/AC 10 10 Polyethylene<br />
10 x 15<br />
wall 150 AC/AC 10 10 Polyethylene<br />
10 x 15<br />
wall 150 AC/AC 15 15 Polyethylene<br />
15 x 15<br />
wall 150 AC/AC 30 30 Polyethylene<br />
30 x 15<br />
wall 200 AC/AC 50 25 Ethafoam<br />
50mm<br />
wall 200 Hardwood/AC 50 25 Ethafoam<br />
50mm<br />
wall 200 Softwood/AC 25 12 Ethafoam<br />
30mm<br />
wall 200 Steel/AC 50 25 Ethafoam<br />
50mm<br />
wall 215 AC/AC 30 15 Ethafoam<br />
40mm<br />
wall 215 AC/AC 15 10 Ethafoam<br />
25mm<br />
wall 215 Hardwood/AC 15 10 Ethafoam<br />
25mm<br />
wall 215 Steel/AC 15 10 Ethafoam<br />
25mm<br />
wall 250 AC/AC 20 Polyethylene<br />
20mm<br />
wall 250 AC/AC 40 Polyethylene<br />
40mm<br />
wall 250 AC/AC 10 Polyethylene<br />
10mm<br />
wall 250 AC/AC 25 Polyethylene<br />
25mm<br />
Configeration:<br />
Non-fire Side<br />
Depth of<br />
Sealant (mm)<br />
Fire<br />
Resistance<br />
(min)<br />
Integrity<br />
(E)<br />
Fire<br />
Resistance<br />
(min)<br />
Insulation<br />
(I)<br />
Cert.<br />
No.<br />
155 105 022b/05<br />
51 44<br />
47 47<br />
72 62<br />
243 65<br />
243 29<br />
10 155 47<br />
25 240 92<br />
6 240 207<br />
15 240 73<br />
53 53<br />
243 29<br />
30 265 265<br />
15 265 230<br />
10 265 265<br />
200 166<br />
227 227<br />
240 233<br />
245 82<br />
96 93<br />
55 54<br />
77 39<br />
243 44<br />
243 29<br />
40 29<br />
243 16<br />
10 240 122<br />
20 240 95<br />
10 240 240<br />
20 240 126<br />
Note:<br />
AC – Aerated Concrete.<br />
Ethafoam – Open cell polyethylene foam rod<br />
Please refer to Rockwool installation instructions for further details<br />
20 Nov 2011 185
PART 1: SECTION 9<br />
FIRE PROTECTED TIMBER STAIRS<br />
The timber escape stairs listed in this <strong>section</strong> are assessed against the requirements of Scheme Document<br />
SD 198 which details the requirements of the approval and certification process, and BD2569 Fire<br />
Performance of Escape Stairs Guidance Document which details the method of test and assessment for<br />
escape stairs based on a realistic fire scenario. The procedure consists of a fire test to evaluate the reactionto-fire<br />
performance of the stair assembly and a subsequent load test to evaluate the structural performance of<br />
the stair assembly following a fire incident. The scheme applies only to stairs used in:<br />
· Single occupancy dwellings<br />
· Communal areas in blocks of flats<br />
· Areas where people may congregate as defined in Table 1 of BS 6399-13.<br />
This approval scheme is run in <strong>part</strong>nership with the British Woodworking Federation (BWF).<br />
Jeld-Wen UK Ltd<br />
Snow Hill, Melton Mowbray, Leicestershire LE13 1PD, United Kingdom<br />
Tel: 0845 122 2890<br />
E-mail: staircustomerservices@jeld-wen.co.uk • Website: www.jeld-wen.co.uk/stairs<br />
Certificate No: 1023a to SD198/BD2569 Fire Protected Timber Escape Stair<br />
Fire Protected Timber Escape Stair<br />
Product Name<br />
Stair<br />
Geometry<br />
Timber<br />
Type<br />
Treads/Risers<br />
Timber<br />
Type<br />
Other Timber<br />
Components<br />
(Strings/handrail,<br />
newel posts<br />
and balusters)<br />
Stair<br />
Treatment<br />
applied<br />
Jeld-Wen Fire Protected Stair Straight flight FR MDF / FR MDF Kerto-S / Hemlock Pressure<br />
Impregnation<br />
Straight flight FR MDF / FR MDF Kerto-S / Softwood Intumescent<br />
coating<br />
Straight flight FR MDF / FR MDF Kerto-S / Softwood Jeld-Wen 3<br />
<strong>part</strong> primer<br />
Dog-leg<br />
Parana<br />
Kerto-S / Hemlock Intumescent<br />
Pine/Plywood<br />
coating<br />
Dog-leg MDF / MDF Kerto-S / Hemlock Intumescent<br />
coating<br />
Dog-leg FR MFD / FR MDF Kerto-S / Hemlock Pressure<br />
Impregnation<br />
Dog-leg<br />
Parana<br />
Kerto-S / Hemlock Pressure<br />
Pine/Plywood<br />
Impregnation<br />
Cert. No.<br />
1023a/01<br />
1023a/02<br />
1023a/03<br />
1023a/04<br />
1023a/05<br />
1023a/06<br />
1023a/07<br />
Notes:<br />
1. All stair cases must be under-drawn with a single 12.5mm layer of Type F plasterboard fixed to the strings with 25mm clout nails at<br />
150mm maximum centres.<br />
2. The maximum permitted span for the treads are 1160mm between strings.<br />
3. LPCB ref No. 1023a/04, /05, /06 and /07 Dog-leg systems cover alternative geometries to those tested such as left or right handed<br />
returns with a minimum distance of 110mm between return flights and a minimum landing of 2340mm .<br />
4. Approved installation configurations and Timber treatment processes are shown below.<br />
186 20 Nov 2011
PART 1: SECTION 9<br />
FIRE PROTECTED TIMBER STAIRS<br />
LPCB ref<br />
No.<br />
LPCB ref<br />
1023a/01<br />
Component Treatment Process Material<br />
Strings<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class 1<br />
surface spread of flame*<br />
32 x 360 Kerto-S<br />
Treads None 25mm Euroclass C FR MDF by<br />
Premier Forest Products Ltd.<br />
Risers None 12mm Euroclass C FR MDF by<br />
Premier Forest Products Ltd.<br />
Newel posts<br />
Handrail<br />
Balusters<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class 1<br />
surface spread of flame*<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class 1<br />
surface spread of flame*<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class 1<br />
surface spread of flame*<br />
90mm stop chamfered Hemlock<br />
63 x 44 Hemlock<br />
41mm stop chamfered Hemlock<br />
LPCB ref<br />
1023a/02<br />
Strings<br />
2 coats of Envirograf ES/VFR fire<br />
protection coating 12-<br />
15m²/litre/coat for each of 2<br />
coats of base coat applied in<br />
accordance with manufacturers<br />
instructions<br />
32 x 350 Kerto-S<br />
Treads None 25mm Euroclass B FR MDF by<br />
Premier Forest Products Ltd.<br />
Risers None 12mm Euroclass B FR MDF by<br />
Premier Forest Products Ltd.<br />
Newel posts<br />
Handrail<br />
2 coats of Envirograf ES/VFR fire<br />
protection coating 12-<br />
15m²/litre/coat for each of 2<br />
coats of base coat applied in<br />
accordance with manufacturers<br />
instructions<br />
2 coats of Envirograf ES/VFR fire<br />
protection coating 12-<br />
15m²/litre/coat for each of 2<br />
coats of base coat applied in<br />
accordance with manufacturers<br />
instructions<br />
90 x 90 softwood square stop<br />
chamfered<br />
63 x 44 softwood profiled<br />
20 Nov 2011 187
PART 1: SECTION 9<br />
FIRE PROTECTED TIMBER STAIRS<br />
Balusters<br />
2 coats of Envirograf ES/VFR fire<br />
protection coating 12-<br />
15m²/litre/coat for each of 2<br />
coats of base coat applied in<br />
accordance with manufacturers<br />
instructions<br />
41 x 41 softwood stop<br />
chamfered<br />
LPCB ref<br />
1023a/03<br />
Strings<br />
Jeld-Wen three <strong>part</strong> primer<br />
applied. All machined edges to<br />
be coated with 2 coats of<br />
Envirograph ES/VFR.<br />
32 x 350 Kerto-S<br />
Treads None 25mm Euroclass B FR MDF by<br />
Premier Forest Products Ltd<br />
Risers None 12mm Euroclass B FR MDF by<br />
Premier Forest Products Ltd<br />
LPCB ref<br />
1023a/04<br />
Newel posts<br />
Handrail<br />
Balusters<br />
Strings<br />
2 coats of Envirograf ES/VFR fire<br />
protection coating 12-<br />
15m²/litre/coat for each of 2<br />
coats of base coat applied in<br />
accordance with manufacturers<br />
instructions<br />
Jeld-Wen three <strong>part</strong> primer<br />
applied. All machined edges to<br />
be coated with 2 coats of<br />
Envirograph ES/VFR.<br />
Jeld-Wen three <strong>part</strong> primer<br />
applied. All machined edges to<br />
be coated with 2 coats of<br />
Envirograph ES/VFR.<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
90 x 90 softwood square stop<br />
chamfered<br />
63 x 44 softwood profiled<br />
41 x 41 softwood stop<br />
chamfered<br />
32 x 360 Kerto-S<br />
Treads<br />
Risers<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
27mm Parana Pine<br />
15mm Plywood<br />
188 20 Nov 2011
PART 1: SECTION 9<br />
FIRE PROTECTED TIMBER STAIRS<br />
Newel posts<br />
Handrail<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
90mm stop chamfered Hemlock<br />
63 x 44 Hemlock<br />
Balusters<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
41mm stop chamfered Hemlock<br />
LPCB ref<br />
1023a/05<br />
Strings<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
32 x 360 Kerto-S<br />
Treads<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
25mm MDF from Premier Forest<br />
products Ltd.<br />
Risers<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
12mm MDF from Premier Forest<br />
Products Ltd.<br />
Newel posts<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
90mm stop chamfered Hemlock<br />
Handrail<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
63 x 44 Hemlock<br />
Balusters<br />
Aquafire HP coating system<br />
comprising a primer, two <strong>part</strong><br />
basecoat and two <strong>part</strong> topcoat<br />
applied in accordance with<br />
manufacturer’s instructions.<br />
41mm stop chamfered Hemlock<br />
20 Nov 2011 189
PART 1: SECTION 9<br />
FIRE PROTECTED TIMBER STAIRS<br />
LPCB ref<br />
1023a/06<br />
Strings<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class O<br />
surface spread of flame*<br />
32 x 360 Kerto-S<br />
Treads None 25mm Euroclass B FR MDF by<br />
Premier Forest Products Ltd.<br />
Risers None 12mm Euroclass B FR MDF by<br />
Premier Forest Products Ltd.<br />
Newel posts<br />
Handrail<br />
Balusters<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class O<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class O<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class O<br />
surface spread of flame*<br />
90mm stop chamfered Hemlock<br />
63 x 44 Hemlock<br />
41mm stop chamfered Hemlock<br />
LPCB ref<br />
1023a/07<br />
Strings<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class O<br />
surface spread of flame*<br />
32 x 360 Kerto-S<br />
Treads<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class O<br />
surface spread of flame*<br />
27mm Parana Pine<br />
Risers<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class O<br />
surface spread of flame*<br />
15mm Plywood<br />
Newel posts<br />
Handrail<br />
Balusters<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class O<br />
surface spread of flame*<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class O<br />
surface spread of flame*<br />
Dricon pressure impregnation fire<br />
retardant treatment by Arch<br />
Chemicals to achieve a Class O<br />
surface spread of flame*<br />
90mm stop chamfered Hemlock<br />
63 x 44 Hemlock<br />
41mm stop chamfered Hemlock<br />
190 20 Nov 2011
Part<br />
2<br />
FIRE DOORS AND<br />
SHUTTERS<br />
(INCORPORATING<br />
INSTALLER SCHEME FOR<br />
FIRE AND SECURITY<br />
DOORS)
PART 2: FIRE DOORS AND SHUTTERS (INCORPORATING INSTALLER<br />
SCHEME FOR FIRE AND SECURITY DOORS)<br />
INTRODUCTION<br />
Fire doors and shutters contribute to the passive fire protection of buildings by maintaining the:<br />
fire separation of com<strong>part</strong>ment walls, while allowing the passage of persons or objects<br />
fire separation in shafts or service ducts that penetrate com<strong>part</strong>ment floors<br />
protection provided by walls forming protected routes for means of escape.<br />
In addition to careful design and product selection, it is recommended that all products are installed and<br />
maintained by LPCB approved contractors who have demonstrated their competence.<br />
Products<br />
Doors and shutter assemblies are approved in accordance with: LPS 1056: Test and Evaluation<br />
Requirements for the Approval and Listing of Fire Doorsets, Lift Landing Doors and Shutter Assemblies.<br />
The fire testing element of this LPS is based on BS 476:Part 20 - Method for determination of the fire<br />
resistance of elements of construction (general principles) or BS EN 1634-1 Fire resistance test for doors and<br />
shutter assemblies- Part 1: Fire doors and shutters, BS EN 81-58 Landing doors fire resistance test and BS<br />
EN 1366-7 Fire resistance tests for service installations - Part 7 Conveyor systems and their enclosures.<br />
LPS 1056 also includes requirements for the reliability testing of the door and shutter assemblies, and<br />
assessment procedures for doors and shutters that are too big to be directly fire tested.<br />
Installation contractors<br />
LPCB approved installation contractors are assessed in accordance with: LPS 1271: Requirements for<br />
Approval and Listing of companies installing fire and security doorsets, shutters and smoke barriers.<br />
Maintenance contractors<br />
LPCB approved maintenance contractors who repair and maintain fire doors and shutters are approved in<br />
accordance with: LPS 1197: Requirements for LPCB Approval and Listing of Companies Undertaking the<br />
Maintenance and Repair of Doorsets, Shutters, and Active Smoke/Fire barriers<br />
192 20 Nov 2011
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
This <strong>section</strong> lists firebreak doorsets and shutters approved to LPS 1056 Test and Evaluation requirements for<br />
the LPCB Approval and Listing of Fire Doorsets, Lift Landing Doors and Shutter Assemblies. LPS 1056 is<br />
based upon relevant BS or European test criteria and not only looks at the fire integrity and insulation (where<br />
applicable) but also includes reliability cyclic tests and grading.<br />
For details of the specific fire resistance required for firebreak doors and shutters for different building types,<br />
see the LPC Design Guide for the Fire Protection of Buildings:2000.<br />
Where insulation is marked as 0, this denotes that the insulation was not measured or that it could not be<br />
measured in accordance with the relevant standard.<br />
Andreu Barbera S.L.<br />
Poligono Fuente Del Jarro, C/Ciudad De Sevilla, 20, 46988 Paterna, Valencia, Spain<br />
Tel: +34 96134 3100 • Fax: +34 961 34 0859<br />
E-mail: andreu@andreu.es • Website: www.andreu.es<br />
Certificate No: 922a to LPS 1056: Issue 6<br />
Product<br />
Name<br />
TURIA EI2<br />
60<br />
TURIA EI2<br />
90<br />
TURIA EI2<br />
120<br />
Door<br />
Type<br />
Double<br />
leaf<br />
hinged<br />
doorset<br />
Double<br />
leaf<br />
hinged<br />
doorset<br />
Single<br />
leaf<br />
hinged<br />
doorset<br />
Single<br />
leaf<br />
hinged<br />
doorset<br />
Double<br />
leaf<br />
hinged<br />
doorset<br />
Double<br />
leaf<br />
hinged<br />
doorset<br />
Single<br />
leaf<br />
hinged<br />
doorset<br />
Single<br />
leaf<br />
hinged<br />
doorset<br />
Double<br />
leaf<br />
hinged<br />
doorset<br />
Double<br />
leaf<br />
hinged<br />
doorset<br />
Single<br />
leaf<br />
hinged<br />
doorset<br />
Single<br />
leaf<br />
hinged<br />
doorset<br />
Max leaf<br />
Size<br />
Height<br />
(mm)<br />
Max Leaf<br />
Size<br />
Width<br />
(mm)<br />
Max Leaf Max Leaf<br />
Size Size<br />
Area Glass<br />
(m 2 Type<br />
2710 2446 6.0 25mm<br />
thick<br />
Pyrobel<br />
Fire<br />
Vision Vision Vision<br />
Reliability<br />
(mm) (mm) (m 2<br />
Panel<br />
Max<br />
Clear<br />
View<br />
Height<br />
Panel<br />
Max<br />
Clear<br />
View<br />
Width<br />
Panel<br />
Max<br />
Clear<br />
View<br />
Area<br />
Resisitance<br />
(minutes)<br />
BS476: Part 22<br />
Integrity /<br />
Insulation<br />
(self closing<br />
Durability<br />
Ref<br />
LPS10560<br />
Cause 3.6)<br />
862 756 0.59 60 / 30 No<br />
Performance<br />
Determined<br />
2710 2446 6.0 N/A - - - 60 / 30 No<br />
Performance<br />
Determined<br />
2710 1223 3.0 N/A - - - 60 / 30 No<br />
Performance<br />
Determined<br />
2710 1223 3.0 25mm<br />
thick<br />
Pyrobel<br />
2710 2446 6.0 53mm<br />
thick<br />
Pyrobel<br />
862 756 0.59 60 / 30 No<br />
Performance<br />
Determined<br />
862 728 0.57 90 / 60 No<br />
Performance<br />
Determined<br />
2710 2446 6.0 N/A - - - 90 / 60 No<br />
Performance<br />
Determined<br />
2710 1223 3.0 53mm<br />
thick<br />
Pyrobel<br />
862 728 0.57 90 / 60 No<br />
Performance<br />
Determined<br />
2710 1223 3.0 N/A - - - 90 / 60 No<br />
Performance<br />
Determined<br />
2710 2446 6.0 53mm<br />
thick<br />
Pyrobel<br />
862 728 0.57 120 / 90 No<br />
Performance<br />
Determined<br />
2710 2446 6.0 N/A - - - 120 / 90 No<br />
Performance<br />
Determined<br />
2710 1223 3.0 53mm<br />
thick<br />
Pyrobel<br />
862 728 0.57 120 / 90 No<br />
Performance<br />
Determined<br />
2710 1223 3.0 N/A - - - 120 / 90 No<br />
Performance<br />
Determined<br />
Cert.<br />
No.<br />
922a/01<br />
922a/02<br />
922a/03<br />
Notes:<br />
1. LPCB ref 922a/01, 922a/02 & 922a/03 Doorsets are approved when installed in concrete or masonry walls and must be fixed back to<br />
the supporting construction using four masonry anchors on each jamb.<br />
20 Nov 2011 193
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
2. LPCB ref 922a/01 & 922a/02 single leaf doorsets must be fitted with a Tesa model 50 lock, a Tesa model 2000N panic bar, a Tesa<br />
model 2000 door closer and 1 ½ pairs of steel butt hinges. Double leaf doorsets must be fitted with, on the active leaf, a Tesa model<br />
CF 50 lock and, on the inactive leaf, a Tesa model CF32 two-point latch; both leaves must be fitted with a Tesa model 4000N panic<br />
bar, a Tesa model GD2 door selector and 1 ½ pairs of steel butt hinges. In addition, one leaf must be fitted with a Tesa model<br />
CT2200 door closer and one with a Tesa model CT4000 door closer.<br />
3. LPCB ref 922a/03 single leaf door sets must be fitted with a Tesa model CF50 lock, a Tesa model 2000N panic bar, a Telesco model<br />
Unik Combi door closer and 1 ½ pairs of steel butt hinges. Double leaf doorsets must be fitted with, on the active leaf a Tesa model<br />
CF 50 lock and the inactive leaf with a Tesa model CF32 two-point latch; both leaves must be fitted with a Tesa model 4000N panic<br />
bar, a Tesa model CT4000+S door closer/selector and 1 ½ pairs of steel butt hinges.<br />
4. LPCB ref 922a/01, 922a/02 & 922a/03 The number of vision panels may be increased providing that the distance between the panes<br />
is no less than that between the tested pane and the edge of the leaf and that the size of the leaf cut out area is no greater than that<br />
of the tested doorsets. On this basis, the minimum distances between the backs of the frames of adjacent vision panels and the<br />
backs of the frames and the door leaf edge are 135mm for the TURIA EI2 60-minute doorsets and 147.5mm for the TURIA EI2 90-<br />
minute and 120-minute doorsets, and the maximum total clear view area is 0.49m² (TURIA EI2 60-minute doorsets) and 0.47m²<br />
(TURIA EI2 90-minute and 120-minute doorsets).<br />
Ascot Doors Limited<br />
Britannia Way Industrial Park, Union Road, Bolton BL2 2HE, United Kingdom<br />
Tel: +44 (0)1204 545801 • Fax: +44 (0)1204 545800<br />
E-mail: sales@ascotdoors.co.uk • Website: www.ascotdoors.co.uk<br />
Certificate No: 131a to LPS 1056: Issue 5<br />
Product Name Spec. Door Type Max<br />
Height<br />
(m)<br />
Max<br />
Width<br />
(m)<br />
Max<br />
Area<br />
(m 2 )<br />
Fire Resistance<br />
(min)<br />
BS 476: Part 22<br />
Integrity<br />
Fire Resistance<br />
(min)<br />
BS 476: Part 22<br />
Insulation<br />
Cert. No.<br />
A200 Series 4 Rolling shutter 7.00 7.00 49.00 240 0 131a/01<br />
A400 Series 4 Single - leaf hinged 2.42 1.02 <strong>2.2</strong>4 240 0 131a/02<br />
4 Double - leaf hinged 2.42 2.04 4.48 240 0 131a/03<br />
Attenborough Doors Limited<br />
Merlin Way, Quarry Hill Industrial Estate, Ilkeston, Derbyshire DE7 4RA, United Kingdom<br />
Tel: +44 (0)115 9300815 • Fax: +44 (0)115 9448930<br />
E-mail: information@attenboroughdoor.co.uk • Website: www.attenboroughdoor.co.uk<br />
Certificate No: 145b to LPS 1056: Issue 5<br />
Product Name Spec. Door Type Max<br />
Height<br />
(m)<br />
Max<br />
Width<br />
(m)<br />
Max<br />
Area<br />
(m 2 )<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part 22<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part 22<br />
Insulation<br />
Cert. No.<br />
Attenborough Fire Shutter 4 Rolling shutter 7.00 7.00 49.00 240 0 145b/01<br />
Clark Door Limited<br />
Unit F Central, Kingmoor Park, Carlisle, Cumbria CA6 4SJ, United Kingdom<br />
Tel: +44 (0)1228 522321 • Fax: +44 (0)1228 401854<br />
E-mail: mail@clarkdoor.com • Website: www.clarkdoor.com<br />
Certificate No: 106a to LPS 1056: Issue 6<br />
194 20 Nov 2011
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
Fireman<br />
Product<br />
Name<br />
Door Type<br />
Max<br />
Height<br />
(m)<br />
Max<br />
Width<br />
(m)<br />
Max<br />
Area<br />
(m 2 )<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part<br />
22<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part<br />
22<br />
Insulation<br />
Reliability<br />
(self closing<br />
durability Ref. LPS<br />
1056 Clause 3.6)<br />
Fireman Sliding door 4.0 4.0 16.00 240 0 No performance<br />
determined<br />
Single leaf 2.76 1.423 3.57 240 0 No performance<br />
hinged door<br />
determined<br />
Double leaf 2.76 2.845 7.15 240 0 No performance<br />
hinged door<br />
determined<br />
Cert.<br />
No.<br />
106a/01<br />
106a/02<br />
106a/03<br />
Notes:<br />
1. Clark Door Ltd are also approved under LPS 1271 for installation of Fireman series of fire rated doorsets.<br />
2. 106a/02 & 106a/03 - Vision panels, 6.5mm thick Pyroshield clear glass with maximum dimensions 1000mm wide x 1000mm high.<br />
Maximum area 1m²<br />
3. 106a/03 - Double leaf doors, passive leaf must be fitted with a 3-point latching mechanism that engages in the top of frame, sill and<br />
the active leaf, and the active leaf must be fitted with a full length astragal that overlaps the passive leaf by at least 25mm.<br />
4. 106a/01, 106a/02, & 106a/03 - Door leaf skins can be fabricated from galvanised mild steel or grade 316 stainless steel.<br />
5. 106a/01, 106a/02, & 106a/03 - The doorsets can be installed in a rigid supporting construction such as brick, blockwork or concrete.<br />
The doorsets can also be installed in a composite wall panel system which provides equal or greater fire resistance than the doorset,<br />
when installed in a composite wall panel system the minimum fixing detail described in assessment report CC213834 shall be<br />
provided.<br />
gte Brandschutz AG<br />
Hamburger Straße 2, D-14532 Stahnsdorf, Germany<br />
Tel: +49 3329 6359-0 • Fax: +49 3329 6359-25<br />
E-mail: gte@gte.ag • Website: www.gte.ag<br />
Certificate No: 735a to LPS 1056: Issue 5 excluding installation<br />
Product Name Door Type Max<br />
Height<br />
(m)<br />
CSS<br />
Vertical sliding<br />
conveyor<br />
system shutter<br />
Horizontal<br />
sliding<br />
conveyor<br />
system shutter<br />
Flap type<br />
conveyor<br />
system shutter<br />
(Single)<br />
Flap type<br />
conveyor<br />
system shutter<br />
(Stacked)<br />
Max<br />
Width<br />
(m)<br />
Max<br />
Area<br />
(m 2 )<br />
Fire<br />
Resistance<br />
(m)<br />
BS 476: Part 22<br />
Integrity<br />
Fire<br />
Resistance<br />
(m)<br />
BS 476: Part 22<br />
Insulation<br />
Cert. No.<br />
1.3 1.4 1.82 90 90 735a/01<br />
1.3 1.4 1.82 90 90 735a/02<br />
1.3 1.1 1.43 90 90 735a/03<br />
0.85 1.1 0.935 90 90 735a/04<br />
Notes:<br />
1. LPCB Product Ref. No’s 735a/01, /02, /03 & /04 suitable for installation into masonry walls and Durasteel <strong>part</strong>itions as described in<br />
Assessment report No. CC221812.<br />
2. CSS conveyor system shutters must be regularly maintained in line with the gte Brandschutz recommendations.<br />
20 Nov 2011 195
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
Hart Door Systems<br />
Redburn Road, Westerhope Industrial Estate, Westerhope, Newcastle upon Tyne NE5 1PJ, United Kingdom<br />
Tel: +44 (0)191 214 0404 • Fax: +44 (0)191 271 1611<br />
E-mail: sales@speedor.co.uk • Website: www.speedor.com<br />
Certificate No: 016a to LPS 1056: Issue 5 excluding installation<br />
Product Name Spec. Door Type Max<br />
Height<br />
(m)<br />
Max<br />
Width<br />
(m)<br />
Max<br />
Area<br />
(m 2 )<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part 22<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part 22<br />
Insulation<br />
Cert. No.<br />
Firebrand 4 Face-fixed rolling shutter 7.00 7.00 49.00 240 0 016a/01<br />
Note:<br />
1. Hart Door Systems Ltd are also approved under LPS 1271 for installation of Firebrand rolling shutters.<br />
Hörmann KG Freisen<br />
Bahnhofstrasse 43, D-66629 Freisen, Germany<br />
Tel: +49 (0)6855 993-0 • Fax: +49 (0)6855 993 197<br />
E-mail: roew.frs@hoermann.de • Website: www.hoermann.de<br />
Certificate No: Certificate No: 655a to LPS 1056: Issue 6<br />
Product<br />
Name<br />
HBS 60 C-<br />
1<br />
HBS 60 C-<br />
2<br />
HBS 90 C-<br />
1<br />
HBS 90 C-<br />
2<br />
HBS 120<br />
C-1<br />
HBS 120<br />
C-2<br />
HBS 30 D-<br />
1<br />
HBS 60 D-<br />
1<br />
HBS 90 D-<br />
1<br />
HBS 30 F-<br />
2<br />
HBS 60 F-<br />
2<br />
HBS 90 F-<br />
2<br />
Vision<br />
Transom<br />
Max clear Max clear Max clear<br />
Vision Vision<br />
Fire Reliability (self<br />
(mm)<br />
(mm)<br />
(m 2 Height<br />
(mm)<br />
Width<br />
(mm)<br />
Area<br />
(m 2 5)<br />
Integrity /<br />
Insulation<br />
opening<br />
sizes<br />
Max<br />
Height<br />
opening<br />
sizes<br />
Max<br />
Width<br />
opening<br />
sizes<br />
Max<br />
Area<br />
panel<br />
Max<br />
Clear<br />
View<br />
panel<br />
Max<br />
Clear<br />
View<br />
panel<br />
Max<br />
Clear<br />
View<br />
panel<br />
Option<br />
Available<br />
(see note<br />
resistance<br />
(min)<br />
BS476 Part<br />
22<br />
closing<br />
durability Ref.<br />
LPS1056<br />
clause 3.6)<br />
2500 1250 3.125 781 435 0.34 Yes 60 / 0 No Performance<br />
determined<br />
2500 2500 6.250 781 435 0.34 Yes 60 / 0 No Performance<br />
determined<br />
2500 1250 3.125 781 435 0.34 Yes 90 / 0 No Performance<br />
determined<br />
2500 2500 6.250 781 435 0.34 Yes 90 / 0 No Performance<br />
determined<br />
2500 1250 3.125 - - - Yes 120 / 0 No Performance<br />
determined<br />
2500 2000 5.000 - - - Yes 120 / 0 No Performance<br />
determined<br />
4225 1950 6.580 2085 1080 <strong>2.2</strong>5 No 30 / 0 No Performance<br />
determined<br />
4062 1875 6.330 2085 1080 <strong>2.2</strong>5 No 60 / 0 No Performance<br />
determined<br />
3770 1740 5.850 2085 1080 <strong>2.2</strong>5 No 90 / 0 No Performance<br />
determined<br />
3700 3388 11.372 - - - No 30 / 30 No Performance<br />
determined<br />
3700 3388 11.372 - - - No 60 / 30 No Performance<br />
determined<br />
3458 3166 10.424 - - - No 90 / 30 No Performance<br />
determined<br />
Cert.<br />
No.<br />
655a/07<br />
655a/08<br />
655a/09<br />
655a/10<br />
655a/11<br />
655a/12<br />
655a/13<br />
655a/14<br />
655a/15<br />
655a/16<br />
655a/17<br />
655a/18<br />
Notes:<br />
1. LPCB ref No. 655a/07 & 08 for alternative approved thin/thick rebated doorsets, frame profiles, sill arrangements & door furniture<br />
please refer to BRE assessment report CC 94538 Review 3.<br />
2. LPCB ref No. 655a/09, 10, 11 & 12 for alternative approved thin/thick rebated doorsets, frame profiles, sill arrangements & door<br />
furniture please refer to BRE assessment report CC 92353 Review 3.<br />
3. LPCB ref No. 655a/13, 14 & 15 doorsets are approved with the following hardware only.<br />
a. Hinges - 3 x Schwarte<br />
b. Locking mechanism - A BKS 6065 lock with an additional BKS6138 lock<br />
c. Door closer - Geze TS 4000<br />
d. Door furniture - Eco Schulte 0432-EN 179-DO 20.3 plastic-coated steel lever handles, four dog bolts along the hinge edge.<br />
196 20 Nov 2011
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
4. LPCB ref No. 655a/16, 17 & 18 doorsets are approved with the following hardware only.<br />
a. Hinges - 2 pairs (4) Schwarte FH-615-20-KO on each leaf (passive/active leaf)<br />
b. Door closer - GEZE TS 4000 (active/passive leaf)<br />
c. Locking mechanism - BKS 6065 lock with additional BKS 6138 catch lock (active leaf), and BKS 1899 rebate locking bolt<br />
(passive leaf)<br />
d. Door furniture - ECO Shulte DIN 18273-FS-SG-BB-PZ lever handles (active/passive leaf) along with ECO Shulte SR Basis-1<br />
door selector and three security bolts.<br />
5. Where a doorset is fitted with a transom panel, the transom shall be up to a maximum height of 1000mm and not exceeding the<br />
maximum permitted height of the doorset, and be of the same construction as the door leaf which is fastened to the door frame with<br />
security bolts at the top and steel screws at the bottom at maximum 500mm centres. The transom panel may be fitted into the frame<br />
type either with or without flexible perimeter seals. For LPCB ref no 655a/07, 08, 09 & 10 a vision panel may be fitted within the<br />
transom panel in the same way as for the door leaf, see note 6.<br />
6. LPCB ref No. 655a/07, 08, 09 & 10 Vision panel frames, steel channel spacers, minimum 1.0mm thick are welded to the leaf and<br />
connected together through the door leaf with M5 steel screws and threaded sockets at 250mm nominal centres. The frame depth<br />
which holds the 6.5mm-thick Georgian-wired glass is 15 mm. Ceramic fibre tape, nominally 4mm thick, is fitted between the glass and<br />
the frame. The single and double leaf doorsets may be fitted with one or more vision panels providing the following requirements are<br />
met<br />
a. Where more than one panel is fitted the max total vision area must not exceed 0.34m2 and each vision panel must be<br />
separated by at<br />
least 165mm<br />
b. The vision panel must be a minimum of 165mm from the leaf edge.<br />
c. The arrangement of the vision panels in double leaf doorsets shall be the same in both leaves<br />
7. LPCB ref No. 655a/13, 14 & 15 Vision panel frames, comprising of 2mm-thick T-profiles, 30mm x 30mm, which are connected via<br />
2mm fillet welds, the tail of the T-profiles are covered on both sides with strips of Promatect-L board, 30mm x 15mm. The vision panel<br />
Promaglas 90/35 Type 1.0 is held in place by a 2mm-thick steel glazing bead 44.5mm x 20.5mm fixed back to the glazing support<br />
frame with 4.2mm Ø x 50mm long self tapping screws. The perimeter on both sides is sealed against the glazing beads using EPDM<br />
seals.<br />
8. LPCB ref No. 655a 07, 08, 09, 10,11 & 12 doorsets may be installed in either Masonry minimum 215mm-thick, Concrete/concrete<br />
block minimum 150mm-thick, autoclaved aerated concrete block walls minimum 215mm -thick / 400kg/m³ or Steel stud with<br />
plasterboard or calcium silicate board <strong>part</strong>itions. Where the doorset is installed in a plasterboard or calcium silicate board <strong>part</strong>ition, the<br />
inside of the aperture to which the doorset is being fixed is lined with 2mm thick steel stud channel <strong>section</strong>, with flanges at least<br />
40mm wide. The vertical studs either side of the aperture are fixed top and bottom to either a masonry or concrete supporting<br />
construction, and the horizontal stud along the top of the aperture is fixed to the vertical studs at either end. The door frame shall also<br />
be filled with fire resisting board and fixed to the <strong>part</strong>ition using 5mm diameter self-tapping self-drilling screws.<br />
9. LPCB ref No. 655a/13, 14, 15, 16, 17 & 18 doorsets may be installed in masonry or concrete walls minimum 240mm-thick.<br />
Industrial Door Engineering Limited<br />
Winnington Avenue, Winnington, Northwich, Cheshire CW8 4EQ, United Kingdom<br />
Tel: +44 (0)1606 871832 • Fax: +44 (0)1606 871482<br />
E-mail: sales@industrial-door-eng.co.uk • Website: www.industrial-door-eng.co.uk<br />
Certificate No: 165a to LPS 1056: Issue 6<br />
Product Name Door Type Max<br />
Height<br />
(m)<br />
Max<br />
Width<br />
(m)<br />
Max<br />
Area<br />
(m 2 )<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part 22<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part 22<br />
Insulation<br />
Reliability<br />
(self closing<br />
Durability Ref<br />
LPS 1056<br />
Clause 3.6)<br />
Sentry Rolling shutter 7.0 7.0 49.0 240 0 No<br />
performance<br />
determined<br />
Sentry 2 Rolling shutter 7.0 7.0 49.0 120 0 No<br />
performance<br />
determined<br />
Sentry 1 Compact Rolling shutter <strong>2.2</strong>0 3.40 7.48 60 0 No<br />
performance<br />
determined<br />
Sentry 1 Rolling shutter <strong>2.2</strong>0 <strong>2.2</strong>0 4.84 60 0 No<br />
performance<br />
determined<br />
Cert. No.<br />
165a/01<br />
165a/02<br />
165a/03<br />
165a/04<br />
Notes:<br />
20 Nov 2011 197
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
1. LPCB Ref No. 165a/03 - Sentry 1 Compact rolling shutter can be fitted with either the flat or curved lath.<br />
2. Industrial Door Engineering Limited are also Certified for the installation of fire rated Sentry rolling shutters against the requirements<br />
of LPS 1271.<br />
J Durrance & Co Ltd<br />
Durrance House, 855 London Road, West Thurrock, Essex RM20 3LG, United Kingdom<br />
Tel: +44 (0)1708 258999 • Fax: +44 (0)1708 258900<br />
E-mail: sales@jdurrance.co.uk • Website: www.jdurrance.co.uk<br />
Certificate No: 588a to LPS 1056: Issue 5<br />
Product Name Door Type Max<br />
Height<br />
(m)<br />
Max<br />
Width<br />
(m)<br />
Max Area<br />
(m 2 )<br />
Fire Resistance<br />
(min)<br />
BS 476:Part 22<br />
Integrity<br />
Fire Resistance<br />
(min)<br />
BS 476:Part 22<br />
Insulation<br />
Cert. No.<br />
PyroGuard 275 Rolling shutter <strong>2.2</strong>4 2.55 5.71 120 - 588a/01<br />
L.B.S. Group (incorporating L.B.S Security Services Limited - t/a Specialized Door<br />
Services, Russell Shutters, Olsen Shutters and Ranford Doors)<br />
Unit 6, Sterling Trading Estate, Rainham Road South, Dagenham, Essex RM10 8TX, United Kingdom<br />
Tel: +44 (0)208 526 8572 • Fax: +44 (0)208 984 0378<br />
Certificate No: 247b to LPS 1056: Issue 5<br />
Fireguard<br />
Product<br />
Name<br />
Fireguard<br />
Door Type<br />
Rolling<br />
shutter<br />
Max Height<br />
(m)<br />
Max Width<br />
(m)<br />
Max Area Fire Resistance Integrity/Insulation<br />
(m 2 (min)<br />
BS 476: Part 22<br />
Integrity<br />
Cert.<br />
No.<br />
7.0 10.0 49.0 240/0 247b/01<br />
Notes:<br />
1. LPCB Ref 247b/01 - for a list of the component's and sizes for the shutter dimensions up to the maximum stated please refer to<br />
BRE Global assessment CC203994 Rev 2.<br />
Lincs Doors Limited<br />
Innovation Way, Europarc, Grimsby, North East Lincolnshire DN37 9TT, United Kingdom<br />
Tel: +44 (0)1472 311057 • Fax: +44 (0)1472 311058<br />
E-mail: enquiries@lincsdoors.co.uk • Website: www.lincsdoors.co.uk<br />
Certificate No: 777a to LPS 1056: Issue 6<br />
Product<br />
Name<br />
Pyroshield<br />
Door Type<br />
Single leaf hinged<br />
without vision panel<br />
Single leaf hinged<br />
without vision panel<br />
Single leaf hinged<br />
with vision panel<br />
Single leaf hinged<br />
with vision panel<br />
Max<br />
Height<br />
(m)<br />
Max<br />
Width<br />
(m)<br />
Max Fire<br />
Area Resistance<br />
(m 2 (min)<br />
BS 476: Part<br />
22<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part<br />
22<br />
Insulation<br />
Reliability<br />
(self closing<br />
durability<br />
Ref. LPS 1056<br />
Clause 3.6)<br />
2.114 0.942 1.99 120 0 No performance<br />
determined<br />
2.536 1.130 2.48 60 0 No performance<br />
determined<br />
2.114 0.942 1.99 90 0 No performance<br />
determined<br />
2.536 1.130 2.48 60 0 No performance<br />
determined<br />
Cert.<br />
No.<br />
777a/01<br />
777a/02<br />
198 20 Nov 2011
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
Product<br />
Name<br />
Door Type<br />
Double leaf hinged<br />
without vision panel<br />
Double leaf hinged<br />
without vision panel<br />
Double leaf hinged<br />
with vision panel<br />
Double leaf hinged<br />
with vision panel<br />
Max<br />
Height<br />
(m)<br />
Max<br />
Width<br />
(m)<br />
Max Fire<br />
Area Resistance<br />
(m 2 (min)<br />
BS 476: Part<br />
22<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part<br />
22<br />
Insulation<br />
Reliability<br />
(self closing<br />
durability<br />
Ref. LPS 1056<br />
Clause 3.6)<br />
2.114 1.884 3.98 120 0 No performance<br />
determined<br />
2.536 <strong>2.2</strong>60 4.96 60 0 No performance<br />
determined<br />
2.114 1.884 3.98 90 0 No performance<br />
determined<br />
2.536 <strong>2.2</strong>60 4.96 60 0 No performance<br />
determined<br />
Cert.<br />
No.<br />
777a/03<br />
777a/04<br />
Notes:<br />
1. Lincs Doors Ltd are also approved under LPS 1271 for installation of fire rated doorsets.<br />
2. 777a/02 & 777a/04 - Vision panels, 10mm thick Pyrodur glass with maximum dimensions 245mm wide x 350mm high.<br />
3. 777a/03 & 777a/04 - Double leaf doors, passive leaf must be fitted with a 3-point latching mechanism that engages in the top of<br />
frame, sill and the active leaf, and the active leaf must be fitted with a full length astragal that overlaps the passive leaf by at least<br />
25mm.<br />
4. 777a/01, 777a/02, 777a/03 & 777a/04 - Door leaf skins can be fabricated from galvanised mild steel or grade 316 stainless steel.<br />
5. 777a/01, 777a/02, 777a/03 & 777a/04 - The doorsets can be installed in a rigid supporting construction such as brick, blockwork or<br />
concrete. The doorsets can also be installed in a composite wall panel system which provides equal or greater fire resistance than<br />
the doorset, when installed in a composite wall panel system the minimum fixing detail described in assessment report CC223023<br />
shall be provided.<br />
Mercian Shutters Limited<br />
Pearsall Drive, Brades Road Industrial Estate, Oldbury, West Midlands B69 2RA, United Kingdom<br />
Tel: +44 (0)121 544 6124 • Fax: +44 (0)121 552 6793<br />
E-mail: info@merciandoors.co.uk • Website: www.merciandoors.co.uk<br />
Certificate No: 355b to LPS 1056: Issue 5 excluding installation<br />
Product Name Spec. Door Type Max<br />
Height<br />
(m)<br />
Max<br />
Width<br />
(m)<br />
Max<br />
Area<br />
(m 2 )<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part 22<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part 22<br />
Insulation<br />
Cert. No.<br />
SF Series 4 Rolling shutter 7.00 7.00 49.00 60, 120 & 240 0 355b/01<br />
Rolling shutter 5.00 10.0 50.00 60 & 120 0<br />
Notes:<br />
1. SF series rolling shutters ref 355b/01 - Reference must be made to assessment report no CC242948 issue 2 dated 11 June 2008 to<br />
confirm component dimensions relevant to the system size and fire resistance required.<br />
2. Mercian Shutters Ltd are also approved under LPS 1271 for installation of SF Series fire rated rolling shutters.<br />
Middle East Insulation<br />
P O Box 14225, Dubai, United Arab Emirates<br />
Tel: +971 48801600 • Fax: +971 48801700<br />
Website: contact@mei-uae.com<br />
Certificate No: 708a to LPS 1056: Issue 6.1<br />
Product<br />
Name<br />
FORT/HC<br />
single leaf<br />
doorset<br />
Maximum<br />
leaf size<br />
Height<br />
(mm)<br />
Maximum<br />
leaf size<br />
Width<br />
(mm)<br />
Maximum<br />
leaf size<br />
Area (m²)<br />
Vision<br />
Panel<br />
Glass<br />
type<br />
Vison<br />
panel<br />
Maximum<br />
clear view<br />
height<br />
(mm)<br />
Vision<br />
Panel<br />
Maximum<br />
clear view<br />
width<br />
(mm)<br />
Vision<br />
panel<br />
Maximum<br />
clear view<br />
area (m²)<br />
Transom<br />
Panel<br />
Option<br />
Available<br />
(see note<br />
2)<br />
BS 476:<br />
Part 22<br />
Fire<br />
Resistance<br />
(minutes)<br />
Integrity<br />
BS 476:<br />
Part 22<br />
Fire<br />
Resistance<br />
(minutes)<br />
Insulation<br />
2967 1196 3.22 N/A - - - NO 180 0 708a/01<br />
2968 1056 2.84 6mm<br />
Pyran S<br />
Cert.<br />
No.<br />
500 200 0.10 YES 120 0 708a/03<br />
20 Nov 2011 199
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
Product<br />
Name<br />
FORT/HC<br />
double leaf<br />
doorset<br />
Maximum<br />
leaf size<br />
Height<br />
(mm)<br />
Maximum<br />
leaf size<br />
Width<br />
(mm)<br />
Maximum<br />
leaf size<br />
Area (m²)<br />
Vision<br />
Panel<br />
Glass<br />
type<br />
Vison<br />
panel<br />
Maximum<br />
clear view<br />
height<br />
(mm)<br />
Vision<br />
Panel<br />
Maximum<br />
clear view<br />
width<br />
(mm)<br />
Vision<br />
panel<br />
Maximum<br />
clear view<br />
area (m²)<br />
Transom<br />
Panel<br />
Option<br />
Available<br />
(see note<br />
2)<br />
BS 476:<br />
Part 22<br />
Fire<br />
Resistance<br />
(minutes)<br />
Integrity<br />
BS 476:<br />
Part 22<br />
Fire<br />
Resistance<br />
(minutes)<br />
Insulation<br />
2968 1056 2.84 6mm 805 230 0.17 YES 90 0<br />
Pyran S<br />
2968 1056 2.84 6mm 700 200 0.14 YES 90 0<br />
Pyroshield<br />
2968 1056 2.84 6mm 805 230 0.17 YES 60 0<br />
Pyroshield<br />
2968 1056 2.84 N/A - - - YES 120 0<br />
2337 1017 2.16 6mm 700 200 0.14 YES 120 0 708a/05<br />
Pyran S<br />
2337 1017 2.16 6mm 805 230 0.17 YES 90 0<br />
Pyran S<br />
2337 1017 2.16 6mm 700 200 0.14 YES 90 0<br />
Pyroshield<br />
2337 1017 2.16 6mm 805 230 0.17 YES 60 0<br />
Pyroshield<br />
2337 1017 2.16 N/A - - - YES 120 0<br />
2682 1196 2.91 6mm<br />
Pyran S<br />
2682 1196 2.91 6mm<br />
Pyran S<br />
2682 1196 2.91 6mm<br />
Pyroshield<br />
2682 1196 2.91 6mm<br />
Pyroshield<br />
Cert.<br />
No.<br />
254 254 0.065 YES 120 0 708a/06<br />
700 200 0.140 YES 90 0<br />
700 200 0.140 YES 90 0<br />
805 230 0.168 YES 60 0<br />
Notes:<br />
1. LPCB Ref. 708a/03, 708a/05 & 708a/06 Where a doorset is fitted with a transom panel, the maximum height of the doorset, including<br />
transom panel, should not exceed 3000mm. The transom panel should be a maximum of 580mm high and have the same<br />
construction as the door leaves and be separated from them by a transom bar. The panel should be fastened to the door frame using<br />
5mm Ø bolts via 25mm x 25mm x 60mm long x 2mm-thick clips.<br />
2. LPCB Ref. 708a/01, 708a/03 & 708a/06 Doorset must be fitted with two pairs of hinges per leaf.<br />
3. LPCB Ref. 708a/05 Doorset must be fitted with one-and-a-half pairs of hinges per leaf.<br />
4. The approved doorsets have been tested or assessed for use with the following hardware types;<br />
a. Hinges - FORT stainless steel ball bearing hinges, McKinney butt hinges. Alternative mild steel, galvanised or stainless steel<br />
hinges with characteristics as detailed in assessment report CC 271427.<br />
b. Locking mechanism - Dorma 752F. Alternative locks and latches with characteristics as detailed in assessment report CC<br />
271427.<br />
c. Door furniture - All door furniture shall be manufactured from steel or stainless steel as detailed in assessment report CC 271427.<br />
d. Door closer - Dorma 7601, Dorma TS72 or Geze TX4000 for use with single leaf doorsets, and Dorma TS72 for use with double<br />
leaf doorsets only.<br />
5. LPCB Ref. 708a/01, 708a/03, 708a/05 & 708a/06 the doorsets listed have been tested in a brick wall surround and are therefore<br />
approved when installed in masonry or concrete wall surround only.<br />
Saudi Factory For Fire Equipment Co.<br />
New Industrial Area, PO Box 58469, Riyadh 11515, Kingdom of Saudi Arabia<br />
Tel: +966 1 265 0070 • Fax: +966 1 265 2190<br />
E-mail: qa@sffeco.com.sa • Website: www.sffeco.com<br />
Certificate No: 403c to LPS 1056 Issue 6.1<br />
Product Name<br />
SFFECO FIRE DOOR<br />
Door<br />
Type<br />
Single<br />
leaf,<br />
hinged<br />
steel<br />
doorset<br />
Max<br />
Height<br />
(mm)<br />
Max<br />
Width<br />
(mm)<br />
Max<br />
Area<br />
(m²)<br />
Fire<br />
Resistance<br />
(minutes)<br />
BS 476:<br />
Part 22<br />
Integrity<br />
Fire<br />
Resistance<br />
(minutes)<br />
BS 476:<br />
Part 22<br />
Insulation<br />
Relibility<br />
(self closing<br />
durability<br />
Ref. LPS<br />
1056 Clause<br />
3.6)<br />
2197 1092 2.399 180 0 No<br />
Performance<br />
Determined<br />
Cert. No.<br />
403c/01<br />
Notes.<br />
1. LPCB Ref. No. 403c/01 The SFFECO FIRE DOOR doorset is approved to withstand a fire exposure from the opening side only, as<br />
detailed in BRE Assessment report CC225304.<br />
200 20 Nov 2011
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
Stobich Brandschutz GmbH<br />
Pracherstieg 6, D - 38644, Goslar, Germany<br />
Tel: 00 49 532 157080 • Fax: 00 49 532 157080<br />
E-mail: info@stobich.de • Website: www.stobich.com<br />
Certificate No: 1064a to LPS 1056: Issue 6.1<br />
Product Name<br />
ECClos-Q<br />
conveyor system<br />
closure<br />
Supporting<br />
construction<br />
160mm thick<br />
Plasterboard<br />
<strong>part</strong>ition<br />
(see note 1)<br />
200mm blockwork<br />
wall<br />
(see note 4)<br />
Penetration<br />
sealing<br />
Max leaf<br />
height<br />
(m)<br />
(note 3)<br />
Max leaf<br />
width<br />
(m)<br />
(note 3)<br />
Max leaf<br />
area (m)<br />
(note 3)<br />
Fire Resistance<br />
(Min)<br />
BS EN 1366-7<br />
Integrity/Insulation<br />
Cert. No.<br />
See note 2 1.377 1.940 2.343 120/120 1064a/01<br />
See note 5<br />
See note 6<br />
1.377 1.940 2.343 240/120 1064a/02<br />
Notes:<br />
1. LPCB Ref 1064a/01 - Standard flexible supporting construction according to BS EN 1366-7, table no 3, giving a fire resistance of 120<br />
minutes, a cross bar type steel frame consisting of two uprights spanning from the floor to ceiling with a horizontal steel spanning<br />
between the <strong>section</strong>s (all 100mm x 100mm x 4mm thick) is located within the <strong>part</strong>ition, around the structual opening to bear the load<br />
of the conveyor system. The conveyor system closure shall be face fixed and may be located on the exposed or unexposed side.<br />
2. LPCB Ref 1064a/01 where the conveyor track penetrates the 160mm thick structural opening 1700mm (w) x 1500mm (h) a blockwork<br />
wall/panel is formed below (built from the finsihed floor level), minimum density 350kg/m3, 150mm thick, 800mm high and 2060mm<br />
wide, the top of the wall/panel is lined with a 20mm thick layer of Promatect-H board with the vertical edges protected with 100mm x<br />
25mm x 3mm thick steel angles through fixed to the cross bar steel frame uprights (within the <strong>part</strong>ition) at 200mm centres. A nominal<br />
175mm opening is left around the conveyor track and blockwork wall/panel, this is built up with layers of Promatect-H25/H20/H15/H12<br />
and H10, Promaseal-PL boards and Tenmat Firefly 102. Two 35mm lateral gaps are left between the boards and blockwork wall<br />
which are friction fitted with Rockwool type RPB9 minimum density 90kg/m3 to allow movement/expansion.<br />
3. LPCB Ref 1064a/01 and 1064a/02 The closure leaf is 'T' shaped and may be increased by a maximum of 15% in height and/or 15%<br />
in width provided the surface area of the leaf is not increased by more than 20% from the dimensions given in the table above. The<br />
leaf may not be reduced by more than 50% in width and 75% in height.<br />
4. LPCB Ref 1064a/02 - Standard low density rigid wall construction according to BS EN 1366-7, table no 2, with a minimum density of<br />
613kg/m3. The conveyor system closure shall be face to face fixed and may be located on the exposed or unexposed side.<br />
5. LPCB Ref 1064a/02 where the conveyor track penetrates the 200mm thick structural opening 1700mm (w) x 1500mm (h), a<br />
blockwork wall/panel is formed below minimum density 350kg/m3, 150mm thick and supported 300mm above the finished floor level<br />
with 4 x 300mm and 1 x 500mm L profile fixing brackets 150mm x 100mm x 10mm thick with threaded rods and nuts (M10). The top<br />
of the wall/panel is lined with a 20mm thick layer of Promatect-H board with the vertical edges protected with 100mm x 25mm x 3mm<br />
thick steel angles though fixed back to the 200mm thick wall at 200mm centres. A nominal 175mm opening is left around the<br />
conveyor track and blockwork wall/panel, this is built up with layers of Promatect-H25/H20/H15/H12 and H10, Promaseal-PL boards<br />
and Tenmat Firefly 102. Two 35mm lateral gaps are left between the boards and blockwork wall which are friction fitted with<br />
Rockwool type RPB9 minimum density 90kg/m3 to allow movement/expansion.<br />
6. LPCB Ref 1064a/02 the penetration seal may incorporate a cable penetration, with maximum penetration size of 60mm x 220mm x<br />
175mm (thickness x height x depth). The penetration must be lined with 20mm Promatect-H boards and the perimeter of the opening<br />
sealed with one layer of Tenmat Firefly 102, all control cables must then individually pass through a mineral wool batt (Rockwool<br />
RPB9 minimum density 90kg/m3) which is held in place within the penetration with EMPE glue.<br />
Sunray Engineering Limited<br />
Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL, United Kingdom<br />
Tel: +44 (0)1233 639039 • Fax: +44 (0)1233 625137<br />
E-mail: sales@sunraydoors.co.uk • Website: www.sunraydoors.co.uk<br />
Certificate No: 234b to LPS 1056: Issue 6.1<br />
20 Nov 2011 201
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
Product Name Spec. Door Type Max<br />
Height<br />
(m)<br />
ExcluDoor 4, 2 lock<br />
version<br />
4 Single-leaf hinged<br />
door<br />
Max<br />
Width<br />
(m)<br />
Max<br />
Area<br />
(m 2 )<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part<br />
22<br />
Integrity<br />
Fire<br />
Resistance<br />
(min)<br />
BS 476: Part<br />
22<br />
Insulation<br />
Cert.<br />
No.<br />
<strong>2.2</strong>5 1.05 2.40 30 0 234b/01<br />
Notes:<br />
1. LPCB Ref: 234b/01 this product achieved an integrity rating of 120 minutes when tested opening towards the furnace with the<br />
deadlocks engaged.<br />
2. LPCB Ref 234b/01 this product is also certificated to Security Rating 4 against the requirements of LPS 1175: Issue 5.<br />
3. Sunray Engineering Ltd is also approved to LPS 1271 for installation of fire and security doors, see approval listing for details.<br />
Certificate No: 234b to LPS 1056: Issue 6.1<br />
Product Name<br />
ExcluDoor 4, Mk2 FR<br />
ExcluDoor 3, Mk3 FR<br />
Door<br />
Type<br />
Single-leaf<br />
hinged door<br />
Double-leaf<br />
hinged door<br />
Unequal<br />
width<br />
Double-leaf<br />
hinged door<br />
Single-leaf<br />
hinged door<br />
Double-leaf<br />
hinged door<br />
Unequal<br />
width<br />
Double-leaf<br />
hinged door<br />
Max<br />
leaf<br />
Height<br />
(m)<br />
Max<br />
leaf<br />
Width<br />
(m)<br />
Max leaf<br />
Area<br />
(m2)<br />
Fire<br />
Resistance<br />
(min)<br />
BS EN 1634-1: 2008<br />
Integrity/Insulation<br />
Cert. No.<br />
2.350 1.155 2.71 240/0 234b/02<br />
2.350 1.155 5.42 240/0 234b/03<br />
2.350 1.155 5.42 240/0<br />
2.350 1.155 2.71 240/0 234b/04<br />
2.350 1.155 5.42 240/0 234b/05<br />
2.350 1.155 5.42 240/0<br />
Notes:<br />
1. LPCB Ref: 234b/02, 234b/03, 234b/04 and 234b/05 doorsets may be fitted with a plain outer face so that there is no method of<br />
external access.<br />
2. LPCB Ref: 234b/02, 234b/03, 264b/04 and 234b/05 these products are also certificated to Security Rating 4 against the requirements<br />
of LPS 1175: Issue 7.<br />
3. Sunray Engineering Ltd is also approved to LPS 1271 for installation of fire and security doors, see approval listing for details.<br />
4. LPCB Ref: 234b/02, 234b/03, 234b/04 and 234b/05 doorsets are approved with the following Surelock Slimline three-point lock<br />
system as shown below.<br />
202 20 Nov 2011
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
Description Code Entry Exit<br />
Key<br />
Access<br />
control<br />
Combination Key Turnknob Access<br />
control<br />
3-point bolting SL304 * <br />
Panic<br />
Emergency<br />
3-point bolting SL305 * <br />
3-point<br />
deadlocking SL301 <br />
3 point<br />
deadlocking<br />
3-point<br />
SL 303<br />
<br />
<br />
deadlocking SL310 <br />
3-point<br />
deadlocking SL311 <br />
3-point<br />
deadlocking SL313 <br />
3-point<br />
deadlocking SL314 <br />
3-point<br />
deadlocking SL315 <br />
3-point<br />
deadlocking SL320 * <br />
3-point<br />
deadlocking SL321 * <br />
3-point<br />
deadlocking SL322 * <br />
3-point<br />
deadlocking SL323 * <br />
3-point<br />
deadlocking SL324 * <br />
3-point<br />
deadlocking SL325 * <br />
3-point<br />
deadlocking SL330 <br />
3-point<br />
deadlocking SL335 <br />
Technocover Limited (incorporating TechnoRail and Strataform)<br />
Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom<br />
Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527<br />
E-mail: techadvice@technocover.co.uk • Website: www.technocover.co.uk<br />
Certificate No: 450g to LPS 1056: Issue 6<br />
Product<br />
Name<br />
Sentinel<br />
UltraSecure<br />
Door Type<br />
DS1/LV<br />
Single leaf<br />
outward<br />
opening<br />
hinged<br />
doorset<br />
uninsulated<br />
Maximum<br />
Leaf Size<br />
Height<br />
(mm)<br />
Maximum<br />
Leaf Size<br />
Width<br />
(mm)<br />
Maximum Door Hardware<br />
Leaf Size Variations<br />
(m 2<br />
2200 940 2.06 SM3,SM4,SM6,SM7,<br />
SM8,SM10,SM13,SM14,<br />
SM16,SM17,SM18,SM20<br />
SM23,SM24,SM26,SM27,<br />
SM28 & SM30.<br />
BS476:<br />
Part 22<br />
Fire<br />
resistance<br />
(minutes)<br />
Integrity<br />
BS476:<br />
Part 22<br />
Fire<br />
resistance<br />
(minutes)<br />
Insulation<br />
Cert.<br />
No.<br />
240 0 450g/01<br />
20 Nov 2011 203
PART 2: SECTION 1.1<br />
FIREBREAK DOORS AND SHUTTERS<br />
Product<br />
Name<br />
Door Type<br />
DS1/LV<br />
Single leaf<br />
outward<br />
opening<br />
hinged<br />
doorset<br />
uninsulated<br />
DS2/LV<br />
Double leaf<br />
outward<br />
opening<br />
hinged<br />
doorset<br />
uninsulated<br />
DS2/LV<br />
Double leaf<br />
outward<br />
opening<br />
hinged<br />
doorset<br />
uninsulated<br />
Maximum<br />
Leaf Size<br />
Height<br />
(mm)<br />
Maximum<br />
Leaf Size<br />
Width<br />
(mm)<br />
Maximum Door Hardware<br />
Leaf Size Variations<br />
(m 2<br />
2640 1128 2.58 SM3,SM4,SM6,SM7,<br />
SM8,SM10,SM13,SM14,<br />
SM16,SM17,SM18,SM20<br />
SM23,SM24,SM26,SM27,<br />
SM28 & SM30.<br />
2768 1218 2.80 SM3,SM4,SM6,SM7,<br />
SM8,SM10,SM13,SM14,<br />
SM16,SM17,SM18,SM20<br />
SM23,SM24,SM26,SM27,<br />
SM28 & SM30.<br />
2215 975 2.15 SM3,SM4,SM6,SM7,<br />
SM8,SM10,SM13,SM14,<br />
SM16,SM17,SM18,SM20<br />
SM23,SM24,SM26,SM27,<br />
SM28 & SM30.<br />
BS476:<br />
Part 22<br />
Fire<br />
resistance<br />
(minutes)<br />
Integrity<br />
BS476:<br />
Part 22<br />
Fire<br />
resistance<br />
(minutes)<br />
Insulation<br />
120 0<br />
Cert.<br />
No.<br />
120 0 450g/02<br />
240 0<br />
Notes:<br />
1. The Sentinel UltraSecure Doorsets are also certified to Security Level 3 & 4 against the requirements of LPS1175: Issue 6.<br />
2. LPCB ref 450g/01 & 450g/02, for approved Door Hardware Variations please refer to Manufacturer's Technical Literature.<br />
3. LPCB ref 450g/01 & 450g/02, the Sentinel UltraSecure Doorsets are approved when installed in concrete/masonry walls or drywall<br />
<strong>part</strong>itions.<br />
204 20 Nov 2011
PART 2: SECTION 1.2<br />
LIFT LANDING DOORS<br />
This <strong>section</strong> lists lift landing doors approved to LPS 1056 Test and Evaluation requirements for the LPCB<br />
Approval and Listing of Fire Doorsets, Lift Landing Doors and Shutter Assemblies. LPS 1056 is based upon<br />
relevant BS or European test criteria and not only looks at the fire integrity and insulation (where applicable)<br />
but also includes reliability cyclic tests and grading.<br />
20 Nov 2011 205
PART 2: SECTION 2<br />
FIRE AND SECURITY DOOR INSTALLERS<br />
This <strong>section</strong> lists companies approved to LPS 1271 Requirements for LPCB Approval and Listing of<br />
Companies Installing Fire and Security Doorsets, Shutters and Smoke Barriers. This standard was developed<br />
to ensure that the product performance is not compromised by poor installation of the fire door or shutter. This<br />
<strong>section</strong> includes manufacturers installing doors and independent installation companies.<br />
Information regarding the security of doors is available in Part 4: Section 5.<br />
Clark Door Limited<br />
Unit F Central, Kingmoor Park, Carlisle, Cumbria CA6 4SJ, United Kingdom<br />
Tel: +44 (0)1228 522321 • Fax: +44 (0)1228 401854<br />
E-mail: mail@clarkdoor.com • Website: www.clarkdoor.com<br />
Certificate No. 106b to LPS 1271: Issue 1<br />
Approved installer of Fireman series of fire rated doorsets.<br />
Grange Door Systems<br />
Unit 12, Bilston Glen Industrial Estate, Edinburgh EH20 9LZ, United Kingdom<br />
Tel: +44 (0)131 440 7000 • Fax: +44 (0)131 440 7003<br />
E-mail: admin@grangedoor.com • Website: www.grangedoor.com<br />
Certificate No. 573b to LPS 1271: Issue 1<br />
Approved installer of Kenrick Fire Stopper Face-fixed rolling shutter (LPCB Ref No 477a/01)<br />
Hart Door Systems<br />
Redburn Road, Westerhope Industrial Estate, Westerhope, Newcastle upon Tyne NE5 1PJ, United Kingdom<br />
Tel: +44 (0)191 214 0404 • Fax: +44 (0)191 271 1611<br />
E-mail: sales@speedor.co.uk • Website: www.speedor.com<br />
Certificate No. 016b to LPS 1271: Issue 1<br />
Approved installer of Firebrand fire rated rolling shutters.<br />
Industrial Door Engineering Limited<br />
Winnington Avenue, Winnington, Northwich, Cheshire CW8 4EQ, United Kingdom<br />
Tel: +44 (0)1606 871832 • Fax: +44 (0)1606 871482<br />
E-mail: sales@industrial-door-eng.co.uk • Website: www.industrial-door-eng.co.uk<br />
Certificate No. 165c to LPS 1271: Issue 1<br />
Approved installer of Sentry, Sentry 1, Sentry 1 Compact and Sentry 2 fire rated rolling shutters.<br />
Kone PLC<br />
Global House, Station Place, Chertsey, Surrey KT16 9HW, United Kingdom<br />
Tel: +44 (0)8451 999 999 • Fax: +44 (0)870 7701144<br />
E-mail: sales.marketinguk@kone.com • Website: www.kone.co.uk<br />
Certificate No. 122P to LPS 1271: Issue 1<br />
Installation of Certified fire rated Rolling Shutters, Hinged Doorsets and Lift Landing Sliding Folding Shutters<br />
206 20 Nov 2011
PART 2: SECTION 2<br />
FIRE AND SECURITY DOOR INSTALLERS<br />
KONE PLC<br />
Full UK Coverage<br />
Helpdesk KONE ONE Tel: +44 (0)8451 999 999 Fax: +44 (0)870 7701144<br />
Email@ sales.marketinguk@kone.com<br />
Mercian Shutters Limited<br />
Pearsall Drive, Brades Road Industrial Estate, Oldbury, West Midlands B69 2RA, United Kingdom<br />
Tel: +44 (0)121 544 6124 • Fax: +44 (0)121 552 6793<br />
E-mail: info@merciandoors.co.uk • Website: www.merciandoors.co.uk<br />
Also at:<br />
Mercian Industrial Doors (Southern) Limited, t/a Mercian Industrial Doors Southern, 10-12 Galleymead Road,<br />
Colnbrook, Slough, Berkshire SL3 0EN, United Kingdom<br />
Certificate No. 355c to LPS 1271: Issue 1<br />
Approved installer of SF series of fire rated rolling shutters.<br />
Prestige Fire Door Services Limited<br />
15 Kings Road, Fleet, Hampshire GU51 3DJ, United Kingdom<br />
Tel: 01252 645534 • Fax: 01252 678742<br />
E-mail: info@prestigefiredoorservices.com • Website: www.prestigefiredoorservices.com<br />
Certificate No. 1066PI to LPS 1271: Issue 1<br />
Approved Installer of certified fire doors and doorsets<br />
Safe Partnership<br />
3 East Street, Wareham, Dorset BH20 4NN, United Kingdom<br />
Tel: +44 (0)1929 551100 • Fax: +44 (0)1929 553300<br />
E-mail: safe@safe<strong>part</strong>nership.org • Website: www.safe<strong>part</strong>nership.co.uk<br />
Certificate No. 835c to LPS 1271: Issue 1<br />
Approved installer of Safe Partnership Ltd Safe Door timber security doors as approved under LPS 1175 (Ref Certificate 835a).<br />
Sunray Engineering Limited<br />
Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL, United Kingdom<br />
Tel: +44 (0)1233 639039 • Fax: +44 (0)1233 625137<br />
E-mail: sales@sunraydoors.co.uk • Website: www.sunraydoors.co.uk<br />
Certificate No. 234e to LPS 1271: Issue 1<br />
Approved installer of certified Sunray Excludoor 3, Excludoor 3 MK 2 and Excludoor 4 (Ref product certificates 234b, 234c and 234d).<br />
20 Nov 2011 207
PART 2: SECTION 3<br />
SERVICE AND MAINTENANCE OF DOORS<br />
This <strong>section</strong> lists companies approved to LPS 1197 Requirements for LPCB Approval and Listing of<br />
Companies Undertaking the Maintenance and Repair of Doorsets, Shutters, and Active Smoke/Fire Barriers.<br />
The effectiveness of a door is dependent upon regular inspection and servicing in accordance with the<br />
manufacturer’s recommendations. Companies approved to LPS 1197 have demonstrated their ability to carry<br />
out this work effectively. The listings include the geographical areas covered by the companies and the level<br />
of service provided.<br />
For the purposes of this document, the term fire door comprises any doorset or shutter assembly including<br />
any frame or guide, door leaf or leaves, rolling or folding curtain etc. which is designed to give a fire resisting<br />
capability when used for closing off permanent openings in separating elements of construction, including<br />
apertures for lift landing doors. This includes any side panels, vision panels or transom panels together with<br />
the door hardware and any seals (whether provided for the purpose of fire resistance and/or smoke control or<br />
for other purposes such as draught or acoustic reduction) which form the assembly.<br />
Ascot Doors Limited<br />
Britannia Way Industrial Park, Union Road, Bolton BL2 2HE, United Kingdom<br />
Tel: +44 (0)1204 545801 • Fax: +44 (0)1204 545800<br />
E-mail: sales@ascotdoors.co.uk • Website: www.ascotdoors.co.uk<br />
Certificate No. 131c to LPS 1197<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
On site within 4 hours of all of England, Scotland and Wales.<br />
Bond Engineering (Maintenance) Ltd<br />
PO Box 7, North Road, Loughborough, Leicestershre LE11 1RL, United Kingdom<br />
Tel: 0844 5611 007 • Fax: +44 (0)1509 231638<br />
E-mail: info@bondengineeringuk.com • Website: www.bondengineeringuk.com<br />
Certificate No. 908a to LPS 1197: Issue 3<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
On site within 4 hours of call in West Midlands, Staffordshire, Hereford, Worcester, Warwickshire, Milton Keynes, Northamptonshire,<br />
Peterborough, Lincolnshire, Nottinghamshire, Derbyshire, South Yorkshire and Leicestershire.<br />
Crawford UK Limited<br />
Central & Southern UK<br />
7 Churchill Way, 35A Business Park, Chapeltown, Sheffield, South Yorkshire S35 2PY, United Kingdom<br />
Tel: +44 (0)870 609 4474 • Fax: +44 (0)114 257 4397<br />
E-mail: service.uk@crawfordsolutions.com • Website: www.crawfordsolutions.uk.com<br />
Certificate No. 001c to LPS 1197<br />
General servicing/maintenance<br />
Maintenance contracts<br />
Yes<br />
Yes<br />
208 20 Nov 2011
PART 2: SECTION 3<br />
SERVICE AND MAINTENANCE OF DOORS<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
Out of office hours: Tel: +44 (0)1244 355235.<br />
Crawford UK Limited<br />
Northern UK<br />
First Floor, Cedar House, Quarrywood Court, Livingston, West Lothian EH54 6AX, United Kingdom<br />
Tel: +44 (0)1506 417237 • Fax: +44 (0)1506 412726<br />
E-mail: service.uk@crawfordsolutions.com • Website: www.crawfordsolutions.uk.com<br />
Certificate No. 001c/02 to LPS 1197<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
Out of office hours: Tel: +44 (0)1244 355235.<br />
Grange Door Systems<br />
Unit 12, Bilston Glen Industrial Estate, Edinburgh EH20 9LZ, United Kingdom<br />
Tel: +44 (0)131 440 7000 • Fax: +44 (0)131 440 7003<br />
E-mail: admin@grangedoor.com • Website: www.grangedoor.com<br />
Certificate No. 573a to LPS 1197<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
On site within 4 hours of call in Scotland, Cumbria, North Lancashire, Teesside and Tyneside.<br />
Industrial Door Engineering Limited<br />
Winnington Avenue, Winnington, Northwich, Cheshire CW8 4EQ, United Kingdom<br />
Tel: +44 (0)1606 871832 • Fax: +44 (0)1606 871482<br />
E-mail: sales@industrial-door-eng.co.uk • Website: www.industrial-door-eng.co.uk<br />
Certificate No. 165b to LPS 1197<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
On site within 4 hours of call in Cheshire, Clwyd, Derbyshire, Greater Manchester, Gwynedd, Lancashire, Merseyside and Yorkshire.<br />
20 Nov 2011 209
PART 2: SECTION 3<br />
SERVICE AND MAINTENANCE OF DOORS<br />
Kone PLC<br />
Global House, Station Place, Chertsey, Surrey KT16 9HW, United Kingdom<br />
Tel: +44 (0)8451 999 999 • Fax: +44 (0)870 7701144<br />
E-mail: sales.marketinguk@kone.com • Website: www.kone.co.uk<br />
Helpdesk KONE ONE<br />
KONE PLC, Global House, Station Place, Chertsey, Surrey KT16 9HW, United Kingdom<br />
Tel: +44 (0)8451 999 999 • Fax: +44(0)870 770 1144<br />
E-mail: sales.marketinguk@kone.com • Website: www.kone.co.uk<br />
Certificate No. 122n to LPS 1197<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
Onsite within 4 hours of call, Full UK Coverage<br />
L.B.S. Group (incorporating L.B.S Security Services Limited - t/a Specialized Door<br />
Services, Russell Shutters, Olsen Shutters and Ranford Doors)<br />
Unit 6, Sterling Trading Estate, Rainham Road South, Dagenham, Essex RM10 8TX, United Kingdom<br />
Tel: +44 (0)208 526 8572 • Fax: +44 (0)208 984 0378<br />
Certificate No. 247a to LPS 1197<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
On site within 4 hours of call-out in Bedfordshire, Berkshire, Buckinghamshire, Cambridgeshire, Essex, Hampshire, Hertfordshire, Kent,<br />
London, Norfolk, Northamptonshire, Oxfordshire, Suffolk, Surrey, East Sussex, West Sussex.<br />
Mercian Shutters Limited<br />
Pearsall Drive, Brades Road Industrial Estate, Oldbury, West Midlands B69 2RA, United Kingdom<br />
Tel: +44 (0)121 544 6124 • Fax: +44 (0)121 552 6793<br />
E-mail: info@merciandoors.co.uk • Website: www.merciandoors.co.uk<br />
also at:<br />
Mercian Industrial Doors (Southern) Limited, t/a Mercian Industrial Doors Southern, 10-12 Gallymead Road,<br />
Colnbrook, Slough, Berkshire SL3 0EN, United Kingdom<br />
Certificate No. 355a to LPS 1197<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
On site within 4 hours of call in Hereford and Worcestershire, Shropshire, Staffordshire, Warwickshire and West Midlands.<br />
210 20 Nov 2011
PART 2: SECTION 3<br />
SERVICE AND MAINTENANCE OF DOORS<br />
Safe Partnership<br />
3 East Street, Wareham, Dorset BH20 4NN, United Kingdom<br />
Tel: +44 (0)1929 551100 • Fax: +44 (0)1929 553300<br />
E-mail: safe@safe<strong>part</strong>nership.org • Website: www.safe<strong>part</strong>nership.co.uk<br />
Certificate No. 835b to LPS 1197: Issue 3<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
No<br />
24 hour answering service Yes<br />
24 hour emergency service No<br />
Scope: Area of cover, all regions of England, Wales and Northern Ireland.<br />
Maintenance and repair of Safe Partnership Ltd Safe Door timber security doors approved to LPS 1175 (Ref cert. 835a) only.<br />
Response service arising from perpetrators attempting or gaining entry into sanctuary or safe room based on agreed priority system.<br />
Stanair Industrial Door Services Limited<br />
2 Henson Way, Telford Way Industrial Estate, Kettering, Northamptonshire NN16 8PX, United Kingdom<br />
Tel: +44 (0)1536 482187 • Fax: +44 (0)1536 411799<br />
E-mail: info@stanair.co.uk • Website: www.stanair.co.uk<br />
Certificate No. 141a to LPS 1197- Issue 3<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
On site within 4 hours of call in Bedfordshire, Buckinghamshire, Cambridgeshire, Leicestershire, Northamptonshire.<br />
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated<br />
Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)<br />
Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL, United Kingdom<br />
Tel: +44 (0)161 205 2321 • Fax: +44 (0)161 455 4459<br />
Website: www.tycofis.com<br />
Certificate No. 014c/01 to LPS 1197<br />
General servicing/maintenance No (see note)<br />
Maintenance contracts Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
On site within 4 hours of call in mainland UK.<br />
Note: General service/maintenance operated through Barnsley and Wigan offices.<br />
20 Nov 2011 211
PART 2: SECTION 3<br />
SERVICE AND MAINTENANCE OF DOORS<br />
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated<br />
Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)<br />
Albion Road, Carlton Industrial Estate, Barnsley S71 3HW, United Kingdom<br />
Tel: +44 (0)1226 702000 • Fax: +44 (0)1226 702001<br />
Website: www.tycofis.com<br />
Certificate No. 014c/02 to LPS 1197<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
On site within 4 hours of call in mainland UK.<br />
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated<br />
Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)<br />
Unit 4, Bradley Hall Industrial Estate, Bradley Lane, Standish, Wigan WN6 0XQ, United Kingdom<br />
Tel: +44 (0)161 205 2321 • Fax: +44 (0)161 455 4459<br />
Website: www.tycofis.com<br />
Certificate No. 014c/03 to LPS 1197<br />
General servicing/maintenance Yes<br />
Maintenance contracts<br />
Yes<br />
24 hour answering service Yes<br />
24 hour emergency service Yes<br />
On site within 4 hours of call in mainland UK.<br />
212 20 Nov 2011
Part<br />
3<br />
SMOKE AND FIRE<br />
VENTILATION SYSTEMS
PART 3: SMOKE AND FIRE VENTILATION SYSTEMS<br />
INTRODUCTION<br />
Fire ventilation systems are installed to:<br />
Keep escape and access routes free from smoke.<br />
Facilitate fire fighting operations by creating a smoke free layer.<br />
Delay and/or prevent flashover and the subsequent full development of the fire.<br />
Protect equipment, furnishings, contents, etc.<br />
Reduce the thermal effects on structural components during a fire.<br />
Reduce damage caused by thermal decomposition of products and hot gases.<br />
The key components of smoke and fire ventilation systems, i.e. fire dampers, ductwork, smoke curtains and<br />
powered smoke and heat exhaust ventilation fans, are listed in this <strong>section</strong>.<br />
Their functions are:<br />
Fire dampers:<br />
To maintain com<strong>part</strong>mentation where air distribution ducts pass through com<strong>part</strong>ment walls and<br />
floors.<br />
LPCB approves fire dampers to LPS 1162: Requirements for the approval of fire dampers.<br />
Fire resistant ductwork:<br />
To maintain com<strong>part</strong>mentation when air distribution ducts pass through com<strong>part</strong>ment walls and floors<br />
and where fire resisting dampers are not used to provide the com<strong>part</strong>mentation.<br />
To achieve the same fire resistance in terms of integrity and, if required, insulation as required for the<br />
com<strong>part</strong>ment walls or floors.<br />
LPCB approves fire resistant ductwork to BS 476: Part 24 Fire tests on building materials and structures:<br />
Method for determination of the fire resistance of ventilation ducts.<br />
Smoke curtains:<br />
To create a smoke reservoir by containing and limiting the travel of smoke.<br />
To channel smoke in a predetermined direction.<br />
To prevent or retard smoke entry to another area or void.<br />
LPCB approves Smoke curtains to LPS 1182: Requirements for the approval of fixed fabric smoke curtains,<br />
fixed metal smoke curtains and powered smoke curtains.<br />
Powered smoke and heat exhaust ventilation fans:<br />
To channel heat and smoke in a predetermined direction.<br />
To prevent smoke logging of the protected space.<br />
Powered smoke and heat exhaust ventilation fans are approved in accordance with BS EN 12101-3 Smoke<br />
and heat control systems. Part 3 Specification for powered smoke and heat exhaust ventilation.<br />
Grease filters used in commercial kitchen extract systems:<br />
To reduce flammable and volatile grease droplets from the cooking exhaust of commercial cooking<br />
equipment.<br />
LPCB categorises and approves grease filters in accordance with the requirements of LPS 1263:<br />
Requirements for the approval and listing of the fire performance of grease filters used in commercial kitchen<br />
extract systems.<br />
214 20 Nov 2011
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Fire dampers are installed:<br />
• To maintain com<strong>part</strong>mentation where air distribution ducts pass through com<strong>part</strong>ment walls and floors.<br />
• To achieve the same fire resistance in terms of integrity as required for com<strong>part</strong>ment walls or floors.<br />
• To close completely as soon as a fire is detected.<br />
All the fire resistant dampers listed in Section 1 of this <strong>part</strong> of the list have been tested and assessed against<br />
the requirements of LPS 1162 Requirements and tests for the LPCB approval of fire dampers.<br />
Actionair<br />
Ruskin Air Management, Joseph Wilson Industrial Estate, South Street, Whitstable, Kent CT5 3DU, United<br />
Kingdom<br />
Tel: +44 (0)1227 276100 • Fax: +44 (0)1227 264262<br />
E-mail: sales@actionair.co.uk • Website: www.actionair.co.uk<br />
Certificate No: 017a to LPS 1162: Issue 4<br />
Product<br />
Name<br />
Fire<br />
Shield<br />
Model /<br />
Installation<br />
frame<br />
I/F damper<br />
horizontally<br />
mounted<br />
I/F damper<br />
vertically<br />
mounted<br />
I/F damper<br />
vertically<br />
mounted<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved Installation /<br />
Construction<br />
1250 1000 - Concrete Floor.<br />
Ref - AA10701 Mounted<br />
using a HEVAC/HVCA<br />
frame in a 150mm thick<br />
reinforced aerated<br />
concrete floor. Builders<br />
ties located at 500mm<br />
centres around the frame,<br />
are bent outwards and<br />
wired to 10mm- diameter<br />
stud anchors driven into<br />
the reveal the 15 - 60mm<br />
gap between the frame<br />
and reveal is filled with<br />
mortar or concrete.<br />
1250 1000 - Masonry/concrete Wall.<br />
Ref - AA/F10703 Mounted<br />
using a HEVAC/HVCA<br />
frame in a 150mm thick<br />
masonry/concrete wall.<br />
Builders ties located at<br />
400mm centres around<br />
the frame, 15 - 60mm gap<br />
between the frame and<br />
reveal. The ties are bent<br />
outwards and mortared<br />
into 50mm-deep pockets<br />
cut into the wall.<br />
1250 1000 - Masonry/concrete Wall.<br />
Ref - AA/F10703 Mounted<br />
using a HEVAC/HVCA<br />
frame in a 150mm thick<br />
masonry/concrete wall.<br />
Builders ties located at<br />
400mm centres around<br />
the frame, 15 - 60mm gap<br />
between the frame and<br />
reveal. The ties are bent<br />
outward and mortared<br />
into the gap<br />
BS EN<br />
1366-2<br />
Fire<br />
Performance<br />
(min)<br />
Integrity /<br />
Insulation /<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
Cert.<br />
No.<br />
240 / 0 / 0 Standard 017a/01<br />
240 / 0 / 0 Standard<br />
120 / 0 / 0 Standard<br />
20 Nov 2011 215
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
Model /<br />
Installation<br />
frame<br />
DWFX-F<br />
damper<br />
vertically<br />
mounted<br />
+ Flange<br />
damper<br />
vertically<br />
mounted<br />
DWFX-C<br />
damper<br />
vertically<br />
mounted<br />
S&A<br />
damper<br />
vertically<br />
mounted<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved Installation /<br />
Construction<br />
1250 1000 - Drywall Partition.<br />
Ref - AA/F10705 Mounted<br />
using 2 x 10mm Ø<br />
threaded drop rods<br />
attached to the damper<br />
via steel cleats welded to<br />
the top corners of the<br />
DWFX-F Flange (75mm<br />
wide x 1.2mm thick)<br />
which is tack welded to<br />
the damper casing in a<br />
steel stud <strong>part</strong>ition<br />
120mm to 200mm thick.<br />
(see note 3)<br />
1250 1000 - Masonry/concrete Wall.<br />
Ref - AA/F10707REV2<br />
mounted in a<br />
masonry/concrete wall<br />
minimum 150mm thick,<br />
the Flange (75mm wide x<br />
1.2mm thick) which is<br />
tack welded to the<br />
damper casing is fixed to<br />
the face of the wall the<br />
gap (25mm max) between<br />
the aperture and damper<br />
casing is filled with<br />
Rockwool and held in<br />
place with an angle flange<br />
to the inside of the reveal<br />
or Z flange to the face of<br />
the wall.<br />
1250 1000 - Drywall Partition.<br />
Ref - AA/F10709 mounted<br />
using 2 x 10mm Ø<br />
threaded steel drop rods<br />
attached to angle <strong>section</strong><br />
cleats welded to the top<br />
sides of the damper<br />
casing in a plasterboard<br />
<strong>part</strong>ition min 100mm max<br />
200mm (see note 4)<br />
1250 1000 - Drywall Partition.<br />
Ref - AA/F10711 Infill up<br />
to 675mm mounted using<br />
2 x 10mm Ø threaded<br />
steel drop rods to the<br />
damper via steel cleats<br />
welded to a flange (75mm<br />
wide x 1.2mm thick)<br />
which is tack welded to<br />
the damper casing in a<br />
Rockwool Ablative<br />
Coated Batt within a<br />
plaster board <strong>part</strong>ition<br />
100mm thick (see notes 5<br />
and 6)<br />
BS EN<br />
1366-2<br />
Fire<br />
Performance<br />
(min)<br />
Integrity /<br />
Insulation /<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
120 / 0 / 0 Standard<br />
120 / 0 / 0 Standard<br />
120 / 0 / 0 Standard<br />
120 / 0 / 0 Standard<br />
Cert.<br />
No.<br />
216 20 Nov 2011
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
Smoke<br />
Shield<br />
PTC<br />
Model /<br />
Installation<br />
frame<br />
S&A<br />
damper<br />
vertically<br />
mounted<br />
S&A<br />
damper<br />
vertically<br />
mounted<br />
S&A<br />
damper<br />
vertically<br />
mounted<br />
I/F damper<br />
horizontally<br />
mounted<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved Installation /<br />
Construction<br />
1250 1000 - Masonry/concrete Wall.<br />
Ref - AA/F10713 Infill up<br />
to 675mm mounted using<br />
2 x 10mm Ø threaded<br />
steel drop rods to the<br />
damper via steel cleats<br />
welded to a flange (75mm<br />
wide x 1.2mm thick)<br />
which is tack welded to<br />
the damper casing in a<br />
Rockwool Ablative<br />
Coated Batt within a<br />
masonry/concrete wall<br />
(see note 6)<br />
1250 1000 - Drywall Partition.<br />
Ref - AA/F10715 mounted<br />
using 2 x 100mm Ø<br />
threaded steel drop rods<br />
to a flange (75mm wide x<br />
1.2mm thick) which is<br />
tack welded to the<br />
damper casing in a<br />
plasterboard <strong>part</strong>ition<br />
Stone mineral wool (60 -<br />
100kg/m³) is fitted around<br />
the damper on the<br />
opposite face to the<br />
flange, prior to a steel<br />
installation angle being<br />
riveted to the duct. (see<br />
note 7)<br />
1250 1000 - Masonry/concrete Wall.<br />
Ref - AA/F10717 mounted<br />
using 2 x 10mm Ø<br />
threaded steel cleats<br />
welded to a flange (75mm<br />
wide x 1.2mm thick)<br />
which is tack welded to<br />
the damper casing in a<br />
masonry / concrete wall.<br />
Stone mineral wool (80 -<br />
100kg/m³) is fitted around<br />
the damper on the<br />
opposite face to the<br />
flange, prior to a steel<br />
installation angle being<br />
riveted to the duct.<br />
1000 1000 - Concrete Floor.<br />
Ref - AA/F10700 Mounted<br />
using a HEVAC/HVCA<br />
frame in a 150mm thick<br />
reinforced aerated<br />
concrete floor. Builders<br />
ties located at 500mm<br />
centres around the frame,<br />
are bent outwards and<br />
wired to 10mm- diameter<br />
stud anchors driven into<br />
the reveal the 15 - 60mm<br />
gap between the frame<br />
and reveal is filled with<br />
mortar or concrete.<br />
BS EN<br />
1366-2<br />
Fire<br />
Performance<br />
(min)<br />
Integrity /<br />
Insulation /<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
120 / 0 / 0 Standard<br />
120 / 0 / 0 Standard<br />
120 / 0 / 0 Standard<br />
Cert.<br />
No.<br />
240 / 0 / 120 Standard 017a/04<br />
20 Nov 2011 217
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
Model /<br />
Installation<br />
frame<br />
I/F damper<br />
vertically<br />
mounted<br />
I/F damper<br />
vertically<br />
mounted<br />
DWFX-F<br />
damper<br />
vertically<br />
mounted<br />
+ Flange<br />
damper<br />
vertically<br />
mounted<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved Installation /<br />
Construction<br />
1000 1000 - Masonry/concrete Wall.<br />
Ref - AA/F10702 Mounted<br />
using a HEVAC/HVCA<br />
frame in a 150mm thick<br />
masonry/concrete wall.<br />
Builders ties located at<br />
400mm centres around<br />
the frame. 15 - 60mm gap<br />
between the frame and<br />
reveal. The ties are bent<br />
outwards and mortared<br />
into 50mm-deep pockets<br />
cut into the wall.<br />
1000 1000 - Masonry/concrete Wall.<br />
Ref - AA/F10702 Mounted<br />
using a HEVAC/HVCA<br />
frame in a 150mm thick<br />
masonry/concrete wall.<br />
Builders ties located at<br />
400mm centres around<br />
the frame. 15 - 60mm gap<br />
between the frame and<br />
reveal the ties are bent<br />
outwards and mortared<br />
into the gap<br />
1000 1000 - Drywall Partition.<br />
Ref - AA/F10704 Mounted<br />
using 2 x 10mm Ø<br />
threaded drop rods<br />
attached to the damper<br />
via steel cleats welded to<br />
the top corners of the<br />
DWFX-F Flange (75mm<br />
wide x 1.2mm thick)<br />
which is tack welded to<br />
the damper casing in a<br />
steel stud <strong>part</strong>ition<br />
120mm to 200mm thick.<br />
(see note 3)<br />
1000 1000 - Masonry/concrete Wall.<br />
Ref - AA/F10706REV 2<br />
mounted in a masonry /<br />
concrete wall minimum<br />
150mm thick, the Flange<br />
(75mm wide x 1.2mm<br />
thick) which is tack<br />
welded to the damper<br />
casing is fixed to the face<br />
of the wall the gap (25mm<br />
max) between the<br />
aperture and damper<br />
casing is filled with<br />
Rockwool and held in<br />
place with an angle flange<br />
to the inside of the reveal<br />
or Z flange to the face of<br />
the wall.<br />
BS EN<br />
1366-2<br />
Fire<br />
Performance<br />
(min)<br />
Integrity /<br />
Insulation /<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
240 / 0 / 120 Standard<br />
120 / 0 / 120 Standard<br />
120 / 0 / 120 Standard<br />
120 / 0 / 120 Standard<br />
Cert.<br />
No.<br />
218 20 Nov 2011
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
Model /<br />
Installation<br />
frame<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved Installation /<br />
Construction<br />
DWFX-C 1000 1000 - Drywall Partition.<br />
Ref - AA/F10708 mounted<br />
using 2 x 10mm Ø<br />
threaded steel drop rods<br />
attached to angle <strong>section</strong><br />
cleats welded to the top<br />
sides of the damper<br />
casing in a plasterboard<br />
<strong>part</strong>ition min 100mm max<br />
200mm. (see note 4)<br />
S&A<br />
damper<br />
vertically<br />
mounted<br />
S&A<br />
damper<br />
vertically<br />
mounted<br />
S&A<br />
damper<br />
vertically<br />
mounted<br />
1000 1000 - Drywall Partition.<br />
Ref - AA/F10710 Infill up<br />
to 675mm mounted using<br />
2 x 10mm Ø threaded<br />
steel drop rods to the<br />
damper via steel cleats<br />
welded to a flange (75mm<br />
wide x 1.2mm thick)<br />
which is tack welded to<br />
the damper casing in a<br />
Rockwool Ablative<br />
Coated Batt within a<br />
plaster board <strong>part</strong>ition<br />
100mm thick. (see notes<br />
5 and 6)<br />
1000 1000 - Masonry/concrete Wall.<br />
Ref - AA/F10712 Infill up<br />
to 675mm mounted using<br />
2 x 10mm Ø threaded<br />
steel drop rods to the<br />
damper via steel cleats<br />
welded to a flange (75mm<br />
wide x 1.2mm thick)<br />
which is tack welded to<br />
the damper casing in a<br />
Rockwool Ablative<br />
Coated Batt within a<br />
masonry/concrete wall<br />
(see note 6)<br />
1000 1000 - Drywall Partition<br />
Ref - AA/F10714 mounted<br />
using 2 x 10mm Ø<br />
threaded steel drop rods<br />
to the damper via steel<br />
cleats welded to a flange<br />
(75mm wide x 1.2mm<br />
thick) which is tack<br />
welded to the damper<br />
casing in plasterboard<br />
<strong>part</strong>ition. Stone mineral<br />
wool ( 60 - 10kg/m³ is<br />
fitted around the damper<br />
on the opposite face to<br />
the flange, prior to a steel<br />
installation angle being<br />
riveted. to the duct (see<br />
note 7)<br />
BS EN<br />
1366-2<br />
Fire<br />
Performance<br />
(min)<br />
Integrity /<br />
Insulation /<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
120 / 0 / 120 Standard<br />
120 / 0 / 120 Standard<br />
120 / 0 / 120 Standard<br />
120 / 0 / 120 Standard<br />
Cert.<br />
No.<br />
20 Nov 2011 219
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
CSS -<br />
Circular<br />
Smoke<br />
Shield<br />
Model /<br />
Installation<br />
frame<br />
S&A<br />
damper<br />
vertically<br />
mounted<br />
Damper<br />
Horizontally<br />
Mounted<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved Installation /<br />
Construction<br />
1000 1000 - Masonry/concrete Wall.<br />
Ref - AA/F10716 mounted<br />
using 2 x 10mm Ø<br />
threaded steel drop rods<br />
to the damper via steel<br />
cleats welded to a flange<br />
(75mm wide x 1.2mm<br />
thick) which is tack<br />
welded to the damper<br />
casing in a masonry /<br />
concrete wall. Stone<br />
mineral wool (60 -<br />
100kg/m³) is fitted around<br />
the damper on the<br />
opposite face to the<br />
flange, prior to a steel<br />
installation angle being<br />
riveted to the duct.<br />
- - 355 Concrete Floor.<br />
Ref - AA/F10719 mounted<br />
in a concrete floor min<br />
100mm thick using a<br />
square flange/frame (two<br />
<strong>section</strong>s) and assembled<br />
in situ using M5 tapit<br />
screws where the<br />
<strong>section</strong>s overlap each<br />
other. The flange on the<br />
upper surface is fixed<br />
using drywall screws,<br />
corner voids around the<br />
damper casing within the<br />
thickness of the floor are<br />
packed with compressed<br />
stone wool (nominal<br />
density 28 kg/m³) prior to<br />
fixing the lower<br />
installation frame, which<br />
is fixed in a similar<br />
manner using HA50<br />
Loden anchors. The<br />
nominal gap between the<br />
edge of the aperture and<br />
the damper casing should<br />
be 5mm.<br />
BS EN<br />
1366-2<br />
Fire<br />
Performance<br />
(min)<br />
Integrity /<br />
Insulation /<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
120 / 0 / 120 Standard<br />
Cert.<br />
No.<br />
120 / 0 / 120 Standard 017a/05<br />
220 20 Nov 2011
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
Model /<br />
Installation<br />
frame<br />
Damper<br />
vertically<br />
installed<br />
Damper<br />
vertically<br />
installed<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved Installation /<br />
Construction<br />
- - 355 Drywall Partition.<br />
Ref - AA/F10718 mounted<br />
in a plasterboard <strong>part</strong>ition<br />
(min 100mm max<br />
200mm) using a square<br />
flange/frame (two<br />
<strong>section</strong>s) and assemble in<br />
situ using M5 tapit screws<br />
where the <strong>section</strong>s<br />
overlap each other. The<br />
flanges are fixed to the<br />
stud and track <strong>section</strong>s<br />
around the perimeter of<br />
the aperture using drywall<br />
screws, corner voids<br />
around the damper casing<br />
within the thickness of the<br />
aperture are packed with<br />
compressed stone wool<br />
(nominal density<br />
35kg/m³). The nominal<br />
gap between the edge of<br />
the aperture and the<br />
damper casing should be<br />
5mm. (see note 8)<br />
- - 355 Masonry/concrete Wall.<br />
Ref - AA/F10720 mounted<br />
in a masonry / concrete<br />
wall (min 100mm thick)<br />
using a square<br />
flange/frame (two<br />
<strong>section</strong>s) and assembled<br />
in situ using M5 tapit<br />
screws where the<br />
<strong>section</strong>s overlap each<br />
other. The flanges are<br />
fixed to the wall around<br />
the parameter of the<br />
aperture using M5 steel<br />
anchors, corner voids<br />
around the damper casing<br />
within the thickness of the<br />
aperture are tacked with<br />
compressed stone wool<br />
(nominal density<br />
35kg/m³). The nominal<br />
gap between the edge of<br />
the aperture and the<br />
damper casing should be<br />
5mm.<br />
BS EN<br />
1366-2<br />
Fire<br />
Performance<br />
(min)<br />
Integrity /<br />
Insulation /<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
120 / 0 / 120 Standard<br />
120 / 0 / 120 Standard<br />
Cert.<br />
No.<br />
20 Nov 2011 221
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
CCS -<br />
Circular<br />
Smoke<br />
Shield<br />
CSS -<br />
Circular<br />
Smoke<br />
Shield<br />
Model /<br />
Installation<br />
frame<br />
Damper<br />
vertically<br />
installed<br />
Damper<br />
vertically<br />
installed<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved Installation /<br />
Construction<br />
- - 355 Drywall Partition.<br />
Ref - AA/F10721 Infill up<br />
to 675mm mounted using<br />
2 x 10mm Ø threaded<br />
steel drop rods to the<br />
damper via steel cleats<br />
welded to a flange which<br />
is a square flange/frame<br />
(two <strong>section</strong>s) and<br />
assembled in situ using<br />
M5 tapit screws where the<br />
<strong>section</strong>s overlap each<br />
other in a Rockwool<br />
Ablative Coated Batt<br />
within a plaster board<br />
<strong>part</strong>ition 100mm thick.<br />
(See notes 9 and 10)<br />
- - 355 Masonry/concrete Wall.<br />
Ref - AA/F10722 Infill up<br />
to 875mm mounted using<br />
2 x 10mm Ø threaded<br />
steel drop rods to the<br />
damper via steel cleats<br />
welded to a flange which<br />
is a square flange/frame<br />
(two <strong>section</strong>s) and<br />
assemble in situ using M5<br />
tapit screws where the<br />
<strong>section</strong>s overlap each<br />
other in Rockwool<br />
Ablative Coated Batt<br />
within a masonry /<br />
concrete wall. (see note<br />
10)<br />
BS EN<br />
1366-2<br />
Fire<br />
Performance<br />
(min)<br />
Integrity /<br />
Insulation /<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
120 / 0 / 120 Standard<br />
120 / 0 / 120 Standard<br />
Cert.<br />
No.<br />
Notes;<br />
1. See LPS1162 Issue 4, Table 1.<br />
2. LPCB ref 017a/"01 and 017a/04 damper casing and blades are manufactured from Stainless steel with the casing<br />
manufactured from galvanised steel.<br />
LPCB ref 017a/05 damper casing and blades are manufactured from galvanised steel.<br />
3. The <strong>part</strong>ition comprised a steel framework of steel studs insulated with a layer of Rockwool RW5 (minimum density<br />
100kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture<br />
framed using stud and track with the web of the <strong>section</strong> set flush with the cut edges of the board, the framed aperture was<br />
then lined with one layer of 12.5mm-thick Type F plasterboard. The gap between the perimeter of the damper casing and<br />
the sides of the aperture should be no greater than 15mm wide along the top, bottom and non drive side, 40mm along the<br />
drive side. The gap is packed with Rockwool RW5 stone mineral wool and covered with a Type F plasterboard pattress<br />
overlapping the edge of the <strong>part</strong>ition by minimum 65mm.<br />
4. The <strong>part</strong>ition comprised a steel framework of steel studs insulated with a layer of Rocksilk RS33 (minimum density<br />
33kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture<br />
framed using stud and track with the web of the <strong>section</strong> set flush with the cut edges of the board, the framed aperture was<br />
then lined with one layer of 12.5mm-thick Type F plasterboard. The gap between the vertical sides of the damper casing<br />
and the sides of the aperture should be no greater than 50mm wide. The gap is packed with stone mineral wool (minimum<br />
density 33kg/m³) the top and bottom of the damper casing fits flush with the aperture and is sealed with a bead of<br />
intumescent mastic to each side. A Type F plasterboard pattress overlapping the edge of the <strong>part</strong>ition by minimum 75mm<br />
is then fixed to both sides of the <strong>part</strong>ition.<br />
5. The <strong>part</strong>ition comprised a steel framework of steel studs insulated with a layer of Rockwool RW3 (minimum density<br />
60kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture<br />
framed using stud and track with the web of the <strong>section</strong> set flush with the cut edges of the board, the framed aperture was<br />
then lined with two layers of 12.5mm-thick Type F plasterboard.<br />
6. The Ablative Coated Batt is constructed by fitting the batt in the aperture with the longest edges orientated horizontally.<br />
The batts are glued into the opening and to each other using FirePro glue. The interface between the batts and the<br />
supporting construction is sealed with a 15mm bead of acoustic intumescent sealant. Following installation of the batts, a<br />
coat of Rockwool Ablative coating is applied over both sides of the completed seal. The batts should be cut to size so that<br />
they fit against the damper casing on all four sides and they rest against the flange which is tack welded to one face of the<br />
222 20 Nov 2011
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
damper casing. A 20mm-thick pattress of Rockwool Ablative Coated batt is fitted around the damper on the opposite face<br />
to the flange, prior to a steel installation angle being riveted to the duct.<br />
7. The <strong>part</strong>ition comprised a steel framework of steel studs insulated with a layer of Rockwool RW5 (minimum density<br />
100kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture<br />
framed using stud and track with the web of the <strong>section</strong> set flush with the cut edges of the board, the framed aperture was<br />
then lined with one layer of 12.5mm-thick Type F plasterboard. Stone mineral wool (60 - 100kg/m³) is fitted around the<br />
damper on the opposite face to the flange, prior to a steel installation angle being riveted to the duct.<br />
8. The <strong>part</strong>ition comprised a steel framework of steel studs insulated with a layer of Stone mineral wool (minimum density<br />
38kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture<br />
framed using stud and track with the web of the <strong>section</strong> set flush with the cut edges of the board, the framed aperture was<br />
then lined with one layer of 12.5mm-thick Type F plasterboard.<br />
9. The <strong>part</strong>ition comprised a steel framework of steel studs insulated with a layer of Stone mineral wool (minimum density<br />
100kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture<br />
framed using stud and track with the web of the <strong>section</strong> set flush with the cut edges of the board, the framed aperture was<br />
then lined with two layers of 12.5mm-thick Type F plasterboard.<br />
10. The Ablative Coated Batt is constructed by fitting the batt in the aperture with the longest edges orientated horizontally.<br />
The batts are glued into the opening and to each other using FirePro glue. The interface between the batts and the<br />
supporting construction is sealed with a 15mm bead of acoustic intumescent sealant. Following installation of the batts, a<br />
coat of Rockwool Ablative coating is applied over both sides of the completed seal.<br />
Advanced Air (UK) Limited<br />
PO Box 153, Burrell Way, Thetford IP24 3QU, United Kingdom<br />
Tel: +44 (0)1842 765657 • Fax: +44 (0)1842 753493<br />
E-mail: sales@advancedair.co.uk • Website: www.advancedair.co.uk<br />
Certificate No: 128a to LPS 1162: Issue 3<br />
Product<br />
Name<br />
Curtain<br />
Fire<br />
Damper<br />
Fire Smoke<br />
Control<br />
Damper<br />
Insulated<br />
Fire<br />
Damper<br />
Series<br />
Max<br />
Duct<br />
Size:<br />
Height<br />
Max<br />
Duct<br />
Size:<br />
Width<br />
Max Duct<br />
Size:<br />
Diameter<br />
ISO 10294-1 5<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
0100 1000 1000 1000 E240 Vertical plane<br />
240<br />
0100 1000 1000 1000 E240 Horizontal<br />
plane 240<br />
0200 1000 1000 1000 E240 Vertical plane<br />
240<br />
0200 1000 1000 1000 E240 Horizontal<br />
plane 240<br />
1240 1000 1000 1000 E120 Vertical plane<br />
120<br />
1240 1000 1000 1000 E120 Horizontal<br />
plane 120<br />
1250 1000 1000 1000 E120 Vertical plane<br />
120<br />
1250 1000 1000 1000 E120 Horizontal<br />
plane 120<br />
1260 1000 1000 1000 E120 Vertical plane<br />
120<br />
1260 1000 1000 1000 E120 Horizontal<br />
plane 120<br />
1270 1000 1000 1000 E120 Vertical plane<br />
120<br />
1270 1000 1000 1000 E120 Horizontal<br />
plane 120<br />
2400 1000 1000 1000 ES210/ESI205 Vertical plane<br />
210<br />
2400 1000 1000 1000 ES210 Horizontal<br />
plane 250<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Durability<br />
Standard 2<br />
Corrosion<br />
Marine 3<br />
Tests<br />
Cyclic 4<br />
Satisfactory Not tested Not<br />
tested<br />
Satisfactory Not tested Not<br />
tested<br />
Satisfactory Not tested Not<br />
tested<br />
Satisfactory Not tested Not<br />
tested<br />
Satisfactory Not tested Not<br />
tested<br />
Satisfactory Not tested Not<br />
tested<br />
205 Satisfactory Not tested Not<br />
tested<br />
250<br />
Cert.<br />
No.<br />
128a/01<br />
128a/02<br />
128a/03<br />
Notes:<br />
1. Standard LPS 1162 requirements for normal use, vertical plane.<br />
2. Corrosion test Appendix B LPS 1162 for marine use.<br />
3. Cyclic test Appendix A LPS 1162 for repeated use.<br />
4. LPS 1162 incorporates the requirements of ISO 10294-1<br />
20 Nov 2011 223
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Arabian Thermal Aire Industries Company Ltd<br />
Al-Jubail Industrial City, Tareeg # 118, Al-Sinaiyah-31961, Kingdom of Saudi Arabia<br />
Tel: +966 3 341 5857<br />
E-mail: info@ataiksa.com • Website: www.ataico.com<br />
Certificate No: 699a to LPS 1162: Issue 3<br />
Product Name<br />
ATAI-Waterloo<br />
galvanized steel shutter<br />
ATAI-Waterloo<br />
galvanized steel<br />
smoke/fire damper<br />
Series<br />
Max<br />
Duct<br />
Size:<br />
height<br />
(mm)<br />
Max<br />
Duct<br />
Size:<br />
width<br />
(mm)<br />
Max<br />
Duct<br />
size:<br />
diameter<br />
(mm)<br />
ISO<br />
10294<br />
Fire<br />
Resistance<br />
Integrity<br />
(min) 2<br />
WFA 1000 1250 - - Horizontal<br />
plane - 240<br />
WGDB 1000 1000 - - Horizontal<br />
plane - 240<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Durability<br />
Standard 1<br />
Corrosion<br />
Marine<br />
Test<br />
Cyclic<br />
- Satisfactory Not tested Not<br />
tested<br />
- Satisfactory Not tested Not<br />
tested<br />
Cert.<br />
No.<br />
699a/01<br />
699a/02<br />
Notes:<br />
1. Standard LPS1162 requirement for normal use.<br />
2. Mounted in a steel deck assembly.<br />
BSB Engineering Services Limited<br />
Unit E, Tribune Drive, Trinity Trading Estate, Sittingbourne, Kent ME10 2PD, United Kingdom<br />
Tel: +44 (0)1795 422609 • Fax: +44 (0)1795 429543<br />
E-mail: sales@bsb-dampers.co.uk • Website: www.bsb-dampers.co.uk<br />
Certificate No: 828a to LPS 1162: Issue 4<br />
Product<br />
Name<br />
Model /<br />
Installation<br />
frame<br />
FSD-TD S, C & O /<br />
Horizontal<br />
plane HF<br />
S, C & O /<br />
Vertical<br />
plane HF<br />
S, C & O /<br />
Vertical<br />
plane SA<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved<br />
Installation/Construction<br />
1200 1200 1200 Ref FSD-TD M1-r4<br />
Mounted using a<br />
HEVAC/HVAC frame in a<br />
200mm-thick reinforced<br />
aerated concrete floor of<br />
minimum nominal density<br />
BS EN<br />
1366-2<br />
Fire<br />
performance<br />
(min)<br />
Integrity/<br />
Insulation/<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
Cert.<br />
No.<br />
580kg/m 3 240 / 0 / 240 Standard 828a/03<br />
240 / 0 / 240 Standard<br />
1000 1000 1000 Ref. FSD-TD M2-r4 -<br />
650kg/m 3<br />
Mounted using<br />
HEVAC/HVAC frame into<br />
an aperture in minimum<br />
150mm-thick lightweight<br />
aerated block wall of<br />
minimum nominal density<br />
1000 1000 1000 Ref FSD-TD M3-r4 120 / 0 / 120 Standard<br />
Mounted using a sleeve &<br />
angles method in a min<br />
100mm max 200mm thick<br />
blockwork wall of minimum<br />
nominal density 650kg/m 3<br />
(See Note 5)<br />
224 20 Nov 2011
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
Model /<br />
Installation<br />
frame<br />
S, C & O /<br />
Vertical<br />
plane BF<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved<br />
Installation/Construction<br />
1000 1000 1000 Infill up to 600mm Ref<br />
FSD-TD M4A-r4 Mounted<br />
using 2 x 10mm Ø<br />
threaded steel studs, 1<br />
either side of the damper<br />
casing fixed to steel cleats<br />
welded to the top & bottom<br />
of the damper casing in a<br />
Firetherm Intubatt 1 fire<br />
barrier <strong>part</strong>ition.<br />
(See Note 6)<br />
BS EN<br />
1366-2<br />
Fire<br />
performance<br />
(min)<br />
Integrity/<br />
Insulation/<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
120 / 0 / 120 Standard<br />
Cert.<br />
No.<br />
S, C & O /<br />
Vertical<br />
plane BF<br />
1000 1000 1000 Infill greater than 600mm<br />
Ref FSD-TD M4B-r4<br />
mounted using 2x 10mm<br />
Ø threaded steel studs, 1<br />
either side of the damper<br />
casing fixed to steel cleats<br />
welded to the top & bottom<br />
of the damper casing in a<br />
Firetherm Intubatt 1 fire<br />
barrier <strong>part</strong>ition.<br />
(See Note 6 & 7)<br />
120 / 0 / 120 Standard<br />
S, C & O /<br />
Vertical<br />
plane SA<br />
1000 1000 1000 Ref FSD-TD M5-r5<br />
mounted using a sleeve<br />
and angles method in a<br />
min 100mm max 200mm<br />
thick steel stud <strong>part</strong>ition.<br />
(See Note 8)<br />
120 / 0 / 120 Standard<br />
S, C & O /<br />
Vertical<br />
plane CL<br />
1000 1000 1000 Ref FSD-TD M6-r4<br />
Mounted using 2 x 10mm<br />
Ø threaded steel studs, 1<br />
either side of the damper<br />
casing fixed to steel cleats<br />
welded to the top & bottom<br />
of the damper casing in a<br />
steel stud <strong>part</strong>ition within<br />
an opening in a masonry<br />
wall minimum 100mm<br />
thick & of minimum<br />
nominal density 650kg/m 3.<br />
(See Note 8)<br />
120 / 0 / 120 Standard<br />
S, C & O /<br />
Vertical<br />
plane BF<br />
1000 1000 1000 Infill up to 600mm<br />
Ref.FSD-TD M7A-r4<br />
mounted using 2 x 10mm<br />
Ø threaded steel studs, 1<br />
either side of the damper<br />
casing fixed to steel cleats<br />
welded to the top & bottom<br />
of the damper casing in a<br />
Firetherm Intubatt 1 fire<br />
barrier <strong>part</strong>ition within an<br />
opening in a steel stud<br />
<strong>part</strong>ition minimum 140mm<br />
thick.<br />
(See Note 6 & 8)<br />
120 / 0 / 120 Standard<br />
20 Nov 2011 225
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
FSD-<br />
TD<br />
Model /<br />
Installation<br />
frame<br />
S, C & O /<br />
Vertical<br />
plane BF<br />
FSD-TD S, C & O /<br />
Vertical<br />
plane BF<br />
FD<br />
S, C & O /<br />
Vertical<br />
plane AF<br />
A, B, I, C &<br />
O / Vertical<br />
plane HF<br />
A, B, I, C &<br />
O / Vertical<br />
plane HF<br />
A, B, I, C &<br />
O / Vertical<br />
plane SA<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved<br />
Installation/Construction<br />
1000 1000 1000 Infill greater than 600mm<br />
Ref. FSD-TD M7B-r4<br />
mounted using 2 x 10mm<br />
Ø threaded steel studs, 1<br />
either side of the damper<br />
casing fixed to steel cleats<br />
welded to the top & bottom<br />
of the damper casing in a<br />
Firetherm Intubatt 1 fire<br />
barrier <strong>part</strong>ition within an<br />
opening in a steel stud<br />
<strong>part</strong>ition minimum 140mm<br />
thick.<br />
(See Note 6, 7 & 8)<br />
1000 1000 1000 Infill greater than 600mm<br />
Ref FSD-TD M8-r5<br />
mounted using 2 x 10mm<br />
Ø threaded steel studs, 1<br />
either side of the damper<br />
casing fixed to steel cleats<br />
welded to the top & bottom<br />
of the damper casing in a<br />
Firetherm Intubatt 1 fire<br />
barrier <strong>part</strong>ition within an<br />
opening in a masonry wall<br />
minimum 100mm thick &<br />
of minimum nominal<br />
density 650kg/m 3.<br />
(See Note 6 & 7)<br />
1200 1200 1200 Ref. FSD-TD M9-r5<br />
mounted using an angle<br />
frame in a min 100mm -<br />
max 200mm thick steel<br />
stud <strong>part</strong>ition.<br />
(See Note 9)<br />
BS EN<br />
1366-2<br />
Fire<br />
performance<br />
(min)<br />
Integrity/<br />
Insulation/<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
120 / 0 / 120 Standard<br />
120 / 0 / 120 Standard<br />
120 / 0 / 120 Standard<br />
240 / 0 / 0 Standard 828a/04<br />
1200 1000 1000 Ref FD M1-r1 mounted<br />
580kg/m 3.<br />
using a HEVAC/HVAC<br />
frame in a minimum<br />
150mm-thick reinforced<br />
aerated concrete floor of<br />
minimum nominal density<br />
1200 1000 1000 Ref FD M2-r1 mounted<br />
using HEVAC/HVAC<br />
frame into an aperture in<br />
minimum 150mm-thick<br />
lightweight aerated block<br />
wall of minimum nominal<br />
1200 1000 1000 Ref FD M3-r1 mounted<br />
using a sleeve & angles<br />
method in a min 100mm -<br />
max 200mm thick<br />
blockwork wall of minimum<br />
nominal density 650kg/m 3.<br />
density 650kg/m 3. 240 / 0 / 0 Standard<br />
(See Note 5)<br />
120 / 0 / 0 Standard<br />
Cert.<br />
No.<br />
226 20 Nov 2011
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
Model /<br />
Installation<br />
frame<br />
A, B, I, C &<br />
O / Vertical<br />
plane BF<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved<br />
Installation/Construction<br />
1200 1000 1000 Infill up to 600mm Ref FD<br />
M4A-r1 mounted using 2 x<br />
10mm Ø threaded steel<br />
studs, 1 either side of the<br />
damper casing fixed to<br />
steel cleats welded to the<br />
top & bottom of the<br />
damper casing in a<br />
Firetherm Intubatt 1 fire<br />
barrier <strong>part</strong>ition.<br />
(See Note 6)<br />
BS EN<br />
1366-2<br />
Fire<br />
performance<br />
(min)<br />
Integrity/<br />
Insulation/<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
120 / 0 / 0 Standard<br />
Cert.<br />
No.<br />
A, B, I, C &<br />
O / Vertical<br />
plane BF<br />
1200 1000 1000 Infill greater than 600mm<br />
Ref FD M4B-r1 mounted<br />
using 2 x 10mm Ø<br />
threaded steel studs, 1<br />
either side of the damper<br />
casing fixed to steel cleats<br />
welded to the top & bottom<br />
of the damper casing in a<br />
Firetherm Intubatt 1 fire<br />
barrier <strong>part</strong>ition.<br />
(See Note 6 & 7)<br />
120 / 0 / 0 Standard<br />
A, B, I, C &<br />
O / Vertical<br />
plane SA<br />
1200 1000 1000 Ref FD M5-r1 mounted<br />
using a sleeve and angles<br />
method in a min 100mmmax<br />
200mm thick steel<br />
stud <strong>part</strong>ition.<br />
(See Note 5 & 8)<br />
120 / 0 / 0 Standard<br />
A, B, I, C &<br />
O / Vertical<br />
plane CL<br />
1200 1000 1000 Ref FD M6-r1<br />
mounted using 2 x 10mm<br />
Ø threaded steel studs, 1<br />
either side of the damper<br />
casing fixed to steel cleats<br />
welded to the top & bottom<br />
of the damper casing in a<br />
steel stud <strong>part</strong>ition within<br />
an opening in a masonry<br />
wall minimum 100mm<br />
thick & of minimum<br />
nominal density 650kg/m 3.<br />
(See Note 8)<br />
120 / 0 / 0 Standard<br />
A, B, I, C &<br />
O / Vertical<br />
plane BF<br />
1200 1000 1000 Infill up to 600mm Ref FD<br />
M7A-r1 mounted using 2<br />
x 10mm Ø threaded steel<br />
studs, 1 either side of the<br />
damper casing fixed to<br />
steel cleats welded to the<br />
top & bottom of the<br />
damper casing in a<br />
Firetherm Intubatt 1 fire<br />
barrier <strong>part</strong>ition within an<br />
opening in a steel stud<br />
<strong>part</strong>ition minimum 140mm<br />
thick.<br />
(See Note 6 & 8)<br />
120 / 0 / 0 Standard<br />
20 Nov 2011 227
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
Product<br />
Name<br />
Model /<br />
Installation<br />
frame<br />
A, B, I, C &<br />
O / Vertical<br />
plane BF<br />
Maximum<br />
Duct size<br />
Width<br />
(mm)<br />
Maximum<br />
Duct size<br />
Height<br />
(mm)<br />
Maximum<br />
Duct size<br />
Diameter<br />
(mm)<br />
Approved<br />
Installation/Construction<br />
1200 1000 1000 Infill greater than 600mm<br />
Ref FD M7B-r1<br />
mounted using 2 x 10mm<br />
Ø threaded steel studs, 1<br />
either side of the damper<br />
casing fixed to steel cleats<br />
welded to the top & bottom<br />
of the damper casing in a<br />
Firetherm Intubatt 1 fire<br />
barrier <strong>part</strong>ition within an<br />
opening in a steel stud<br />
<strong>part</strong>ition minimum 140mm<br />
thick.<br />
(See Note 6, 7 & 8)<br />
BS EN<br />
1366-2<br />
Fire<br />
performance<br />
(min)<br />
Integrity/<br />
Insulation/<br />
Leakage<br />
LPS<br />
1162<br />
Class<br />
(Note 1)<br />
120 / 0 / 0 Standard<br />
Cert.<br />
No.<br />
A, B, I, C &<br />
O / Vertical<br />
plane BF<br />
1200 1000 1000 Infill greater than 600mm<br />
Ref FD M8-r1 mounted<br />
using 2 x 10mm Ø<br />
threaded steel studs, 1<br />
either side of the damper<br />
casing fixed to steel cleats<br />
welded to the top & bottom<br />
of the damper casing in a<br />
Firetherm Intubatt 1 fire<br />
barrier <strong>part</strong>ition within an<br />
opening in a masonry wall<br />
minimum 100mm thick &<br />
of minimum nominal<br />
density 650kg/m 3.<br />
(See Note 6 & 7)<br />
120 / 0 / 0 Standard<br />
A, B, I, C &<br />
O / Vertical<br />
plane AF<br />
1200 1000 1000 Ref. FD M9 mounted<br />
using an angle frame in a<br />
min 100mm - max 200mm<br />
thick steel stud <strong>part</strong>ition.<br />
(See Note 9)<br />
120 / 0 / 0 Standard<br />
Notes:<br />
1. See LPS 1162: Issue 4. Table 1<br />
2. LPCB Ref No. 828a/04 approval covers FD dampers constructed from galvanised steel only.<br />
3.. LPCB Ref No. 828a/03, approval covers FSD-TD dampers constructed from a galvanised steel casing with stainless steel blades,<br />
with the exception of the FSD-TD-AF damper which has galvanised steel casing with galvanised blades.<br />
4. The sleeve protrudes from each face of the wall by at least 20mm. The continuous external angles (minimum 40mm x 40mm) are<br />
riveted to the sleeve on both sides of the wall at maximum 150mm centres. Similar internal angles secure the sleeve to the damper<br />
casing.<br />
5. The Firetherm Intubatt 1 fire barrier system comprises of 2 layers of 50mm-thick Firetherm Intubatt 1 (minimum density 180kg/m³)<br />
seperated by a cavity of 40mm and factory coated on both faces with a 1mm-thick coating of ablative mastic. The perimeter of the<br />
coated batts is retained within galvanised steel angles, 50mm x 50mm x 2m, secured at maximum 300mm centres. The junctions<br />
between the damper and the coated batt are pattressed on both sides of the barrier with strips of Firetherm Intubatt 1, 50mm thick x<br />
150mm wide, which are secured by bedding on a layer of Intucoat mastic and fixing with steel pig-tail screws at maximum 200mm<br />
centres. Maximum distance between the damper and the reveal of the wall opening is 600mm.<br />
6. A perimeter frame work of steel angles 50mm x 50mm x 2mm is secured on each side of the opening between the damper and the<br />
reveal of the wall at 300mm centres. Steel angles are then fixed back-to-back at 300mm centres to form T-<strong>section</strong>s, which are then<br />
fixed around the damper to form a frame, of which its sides are no more than 600mm from the damper. The T-<strong>section</strong> from is<br />
secured to the perimeter frame using a series of T-<strong>section</strong>s positioned at maximum 600mm centres in one direction and 1200mm<br />
centres in the other direction. For barriers where the distance between the top of the damper and the top of the barrier is greater than<br />
1.5m, a deflection head detial is required. The maximum distance between the damper and the wall or floor must not exceed 3m.<br />
7. The Partition comprised of a steel framework of 50mm studs clad on each face with two layers of 12.5mm-thick Firecheck GTEC<br />
plasterboard, with the voids between the studs insulated with one layer of 25mm-thick Knauf Acoustic Partition Roll (minimum density<br />
19.5kg/m³) with the aperture to be lined with one layer of 12.5mm-thick Firecheck GTEC plasterboard. The dry fit sleeve & angle<br />
system comprises of a 1.2mm-thick top hat <strong>section</strong> damper casing and 300mm long sleeves with 40mm x 40mm angle type frame<br />
work riveted to the sleeve using 4.8mm Ø steel rivets, centrally positioned within the aperture to act as a carrier frame.<br />
8. The Partition comprised of a steel framework, of 50mm studs clad on each face with two layers of 12.5mm-thick Firecheck GTEC<br />
plasterboard, with the voids between the studs insulated with one layer of 50mm-thick Rockwool Flexi Slab (minimum density<br />
35kg/m³), with the aperture to be lined with one layer of 12.5mm-thick Firecheck GTEC plasterboard. The angle frame comprises of a<br />
steel angle formed from 1.2mm steel and is secured to one side of the damper casing using stitch welds 6-10mm long, at nominal<br />
150mm centres. The leg of the angle fixed to the damper casing is 35mm long. The other leg of the angle must be long enough to<br />
228 20 Nov 2011
PART 3: SECTION 1<br />
FIRE DAMPERS<br />
overlap the <strong>part</strong>ition and be secured at nominal 300mm centres. On the other side of the <strong>part</strong>ition the damper is pattressed on all four<br />
sides using one or more layers of 12.5mm-thick Firecheck GTEC plasterboard cover strips which must overlap the <strong>part</strong>ition by at least<br />
65mm. The cover strips are secured using suitable screws at 300mm centres. A bead of fire/acoustic sealant must be applied<br />
between the edges of each pattress and the spigot & between each pattress and the spigot & between each pattress and the face of<br />
the <strong>part</strong>ition.<br />
20 Nov 2011 229
PART 3: SECTION 2<br />
FIRE RESISTANT DUCTS<br />
Fire resistant ductwork is installed:<br />
<br />
<br />
To maintain com<strong>part</strong>mentation when air distribution ducts pass through com<strong>part</strong>ment walls and floors<br />
where fire resisting dampers are not used to provide the com<strong>part</strong>mentation<br />
To achieve the same fire resistance in terms of integrity, and if required insulation, as required for the<br />
com<strong>part</strong>ment walls or floors.<br />
All the fire resistant ducts listed in Section 2 of this <strong>part</strong> of the list have been tested and assessed against the<br />
requirements of BS 476:Part 24 Fire tests on building materials and structures: Method for determination of<br />
the fire resistance of ventilation ducts.<br />
Certification is limited to the applications and fire resistances given.<br />
Fire Protection Limited<br />
Flamebar House, South Road, Templefields, Harlow, Essex CM20 2AR, United Kingdom<br />
Tel: +44 (0)1279 634 230 • Fax: +44 (0)1279 634 231<br />
E-mail: info@fireprotection.co.uk • Website: www.fireprotection.co.uk<br />
Certificate No: 277a to BS 476: Part 24<br />
Product Name Duct Type Condition Type of<br />
Insulation<br />
(kg/m 3 )<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Cert. No.<br />
Flamebar BW11 Ventilation Fire outside - - 120 15 277a/01<br />
Ventilation Fire outside - - 240 15<br />
Ventilation Fire outside 45 25 120 60<br />
Ventilation Fire outside 45 60 120 60<br />
Ventilation Fire outside 60 40 120 90<br />
Ventilation Fire outside 60 50 120 118<br />
Ventilation Fire outside 60 120 120 120<br />
Ventilation Fire outside 105 50 120 120<br />
Ventilation Fire outside 105 80 120 120<br />
Ventilation Fire outside 105 50 240 208<br />
Ventilation Fire outside 60 120 240 240<br />
Ventilation Fire outside 105 80 240 240<br />
Ventilation Fire outside 105 120 240 240<br />
Ventilation Fire outside 105 100** 240 240<br />
Ventilation Fire inside - - 120 -<br />
Ventilation Fire inside - - 240 -<br />
Ventilation Fire inside 45 25 120 30<br />
Ventilation Fire inside 45 60 120 30<br />
Ventilation Fire inside 60 50 120 45<br />
Ventilation Fire inside 105 50 120 60<br />
Ventilation Fire inside 60 120 120 90<br />
Ventilation Fire inside 105 80 120 90<br />
Ventilation Fire inside 105 120 120 120<br />
Ventilation Fire inside 60 120 240 90<br />
Ventilation Fire inside 105 80 240 90<br />
Ventilation Fire inside 105 120 240 120<br />
Ventilation Fire inside 105 100** 240 120<br />
Smoke outlet Fire outside - - 120 15<br />
Smoke outlet Fire outside - - 240 15<br />
Smoke outlet Fire outside 45 25 120 60<br />
Smoke outlet Fire outside 45 60 120 60<br />
Smoke outlet Fire outside 60 40 120 90<br />
Smoke outlet Fire outside 60 50 120 118<br />
Smoke outlet Fire outside 60 120 120 120<br />
Smoke outlet Fire outside 105 50 120 120<br />
Smoke outlet Fire outside 105 80 120 120<br />
Smoke outlet Fire outside 105 50 240 208<br />
Smoke outlet Fire outside 60 120 240 240<br />
Smoke outlet Fire outside 105 80 240 240<br />
Smoke outlet Fire outside 105 120 240 240<br />
Smoke outlet Fire outside 105 100** 240 240<br />
230 20 Nov 2011
PART 3: SECTION 2<br />
FIRE RESISTANT DUCTS<br />
Product Name Duct Type Condition Type of<br />
Insulation<br />
(kg/m 3 )<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Smoke outlet Fire inside - - 120 -<br />
Smoke outlet Fire inside - - 240 -<br />
Smoke outlet Fire inside 45 25 120 30<br />
Smoke outlet Fire inside 45 60 120 30<br />
Smoke outlet Fire inside 60 50 120 45<br />
Smoke outlet Fire inside 105 50 120 60<br />
Smoke outlet Fire inside 60 120 120 90<br />
Smoke outlet Fire inside 105 80 120 90<br />
Smoke outlet Fire inside 105 120 120 120<br />
Smoke outlet Fire inside 60 120 240 90<br />
Smoke outlet Fire inside 105 80 240 90<br />
Smoke outlet Fire inside 105 120 240 120<br />
Smoke outlet Fire inside 105 100** 240 120<br />
Kitchen extract Fire outside - - 120 15<br />
Kitchen extract Fire outside - - 240 15<br />
Kitchen extract Fire outside 60 50 120 28*<br />
Kitchen extract Fire outside 60 60 120 30*<br />
Kitchen extract Fire outside 105 50 120 44*<br />
Kitchen extract Fire outside 60 120 120 45*<br />
Kitchen extract Fire outside 105 80 120 45*<br />
Kitchen extract Fire outside 105 50 240 44*<br />
Kitchen extract Fire outside 60 120 240 45*<br />
Kitchen extract Fire outside 105 80 240 45*<br />
Kitchen extract Fire outside 105 120 240 60*<br />
Kitchen extract Fire outside 105 100** 240 60*<br />
Kitchen extract Fire inside - - 120 -<br />
Kitchen extract Fire inside - - 240 -<br />
Kitchen extract Fire inside 45 25 120 30<br />
Kitchen extract Fire inside 45 60 120 30<br />
Kitchen extract Fire inside 60 50 120 45<br />
Kitchen extract Fire inside 105 50 120 60<br />
Kitchen extract Fire inside 60 120 120 90<br />
Kitchen extract Fire inside 105 80 120 90<br />
Kitchen extract Fire inside 105 120 120 120<br />
Kitchen extract Fire inside 60 120 240 90<br />
Kitchen extract Fire inside 105 80 240 90<br />
Kitchen extract Fire inside 105 120 240 120<br />
Kitchen extract Fire inside 105 100** 240 120<br />
Cert. No.<br />
Notes:<br />
1. All ducts are protected with 0.7mm to 1.0mm nominal thickness of Flamebar BW11 Fire Proofing.<br />
2. Maximum hanger centres are 1500mm for fire ratings up to two hours and 1000mm for fire ratings up to four hours.<br />
3. The 50mm thick x 60kg/m 3 density mineral wool insulation may be in the form of either slabs or wrap.<br />
* Refers to internal face inside furnace.<br />
** Includes 500mm x 25mm x 105kg/m 3 density mineral wool collar around duct on both sides of penetration seals through fire<br />
com<strong>part</strong>ment walls and floors.<br />
Firespray International Limited<br />
Flamebar House, South Road, Templefields, Harlow, Essex CM20 2AR, United Kingdom<br />
Tel: +44 (0)1279 634 230 • Fax: +44 (0)1279 634 232<br />
E-mail: info@firespray.eu.com • Website: www.firespray.eu.com<br />
Certificate No: 415a to BS 476: Part 24<br />
Product Name Duct Type Condition Type of<br />
Insulation<br />
(kg/m 3 )<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Cert. No.<br />
Flamebar BW11 Ventilation Fire outside - - 120 15 415a/01<br />
Ventilation Fire outside - - 240 15<br />
Ventilation Fire outside 45 25 120 60<br />
Ventilation Fire outside 45 60 120 60<br />
20 Nov 2011 231
PART 3: SECTION 2<br />
FIRE RESISTANT DUCTS<br />
Product Name Duct Type Condition Type of<br />
Insulation<br />
(kg/m 3 )<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Ventilation Fire outside 60 40 120 90<br />
Ventilation Fire outside 60 50 120 118<br />
Ventilation Fire outside 60 120 120 120<br />
Ventilation Fire outside 105 50 120 120<br />
Ventilation Fire outside 105 80 120 120<br />
Ventilation Fire outside 105 50 240 208<br />
Ventilation Fire outside 60 120 240 240<br />
Ventilation Fire outside 105 80 240 240<br />
Ventilation Fire outside 105 120 240 240<br />
Ventilation Fire outside 105 100** 240 240<br />
Ventilation Fire inside - - 120 -<br />
Ventilation Fire inside - - 240 -<br />
Ventilation Fire inside 45 25 120 30<br />
Ventilation Fire inside 45 60 120 30<br />
Ventilation Fire inside 60 50 120 45<br />
Ventilation Fire inside 105 50 120 60<br />
Ventilation Fire inside 60 120 120 90<br />
Ventilation Fire inside 105 80 120 90<br />
Ventilation Fire inside 105 120 120 120<br />
Ventilation Fire inside 60 120 240 90<br />
Ventilation Fire inside 105 80 240 90<br />
Ventilation Fire inside 105 120 240 120<br />
Ventilation Fire inside 105 100** 240 120<br />
Smoke outlet Fire outside - - 120 15<br />
Smoke outlet Fire outside - - 240 15<br />
Smoke outlet Fire outside 45 25 120 60<br />
Smoke outlet Fire outside 45 60 120 60<br />
Smoke outlet Fire outside 60 40 120 90<br />
Smoke outlet Fire outside 60 50 120 118<br />
Smoke outlet Fire outside 60 120 120 120<br />
Smoke outlet Fire outside 105 50 120 120<br />
Smoke outlet Fire outside 105 80 120 120<br />
Smoke outlet Fire outside 105 50 240 208<br />
Smoke outlet Fire outside 60 120 240 240<br />
Smoke outlet Fire outside 105 80 240 240<br />
Smoke outlet Fire outside 105 120 240 240<br />
Smoke outlet Fire outside 105 100** 240 240<br />
Smoke outlet Fire inside - - 120 -<br />
Smoke outlet Fire inside - - 240 -<br />
Smoke outlet Fire inside 45 25 120 30<br />
Smoke outlet Fire inside 45 60 120 30<br />
Smoke outlet Fire inside 60 50 120 45<br />
Smoke outlet Fire inside 105 50 120 60<br />
Smoke outlet Fire inside 60 120 120 90<br />
Smoke outlet Fire inside 105 80 120 90<br />
Smoke outlet Fire inside 105 120 120 120<br />
Smoke outlet Fire inside 60 120 240 90<br />
Smoke outlet Fire inside 105 80 240 90<br />
Smoke outlet Fire inside 105 120 240 120<br />
Smoke outlet Fire inside 105 100** 240 120<br />
Kitchen extract Fire outside - - 120 15<br />
Kitchen extract Fire outside - - 240 15<br />
Kitchen extract Fire outside 60 50 120 28*<br />
Kitchen extract Fire outside 60 60 120 30*<br />
Kitchen extract Fire outside 105 50 120 44*<br />
Kitchen extract Fire outside 60 120 120 45*<br />
Kitchen extract Fire outside 105 80 120 45*<br />
Kitchen extract Fire outside 105 50 240 44*<br />
Kitchen extract Fire outside 60 120 240 45*<br />
Kitchen extract Fire outside 105 80 240 45*<br />
Kitchen extract Fire outside 105 120 240 60*<br />
Kitchen extract Fire outside 105 100** 240 60*<br />
Kitchen extract Fire inside - - 120 -<br />
Kitchen extract Fire inside - - 240 -<br />
Kitchen extract Fire inside 45 25 120 30<br />
Kitchen extract Fire inside 45 60 120 30<br />
Kitchen extract Fire inside 60 50 120 45<br />
Kitchen extract Fire inside 105 50 120 60<br />
Kitchen extract Fire inside 60 120 120 90<br />
Kitchen extract Fire inside 105 80 120 90<br />
Cert. No.<br />
232 20 Nov 2011
PART 3: SECTION 2<br />
FIRE RESISTANT DUCTS<br />
Product Name Duct Type Condition Type of<br />
Insulation<br />
(kg/m 3 )<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire<br />
Resistance<br />
Integrity<br />
(min)<br />
Fire<br />
Resistance<br />
Insulation<br />
(min)<br />
Kitchen extract Fire inside 105 120 120 120<br />
Kitchen extract Fire inside 60 120 240 90<br />
Kitchen extract Fire inside 105 80 240 90<br />
Kitchen extract Fire inside 105 120 240 120<br />
Kitchen extract Fire inside 105 100** 240 120<br />
Cert. No.<br />
Notes:<br />
1. All ducts are protected with 0.7mm to 1.0mm nominal thickness of Flamebar BW11 Fire Proofing.<br />
2. Maximum hanger centres are 1500mm for fire ratings up to two hours and 1000mm for fire ratings up to four hours.<br />
3. The 50mm thick x 60kg/m 3 density mineral wool insulation may be in the form of either slabs or wrap.<br />
* Refers to internal face inside furnace.<br />
** Includes 500mm x 25mm x 105kg/m 3 density mineral wool collar around duct on both sides of penetration seals through fire<br />
com<strong>part</strong>ment walls and floors.<br />
Flameshield Products Limited<br />
9 Zillah Gardens, Wigmore, Gillingham, Kent ME8 0EE, United Kingdom<br />
Tel: 01322 558887<br />
E-mail: neil.david@btconnect.com<br />
Certificate No: 785a to BS 476: Part 24<br />
Product<br />
Name<br />
Duct Type Condition Type / density of<br />
insulation<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
(Integrity/<br />
stability)<br />
Fire<br />
Resistance<br />
(Insulation)<br />
Flameshield Ventilation Fire inside None - 240 - 785a/03<br />
Smoke outlet Fire inside None - 120 -<br />
Kitchen Fire inside None - 120 -<br />
extract<br />
Ventilation Fire<br />
None - 120 -<br />
outside<br />
Smoke outlet Fire<br />
None - 120<br />
outside<br />
Kitchen Fire<br />
None - 120 -<br />
extract outside<br />
Ventilation Fire inside Mineral wool 165 40 120 30 785a/04<br />
kg/m3<br />
Ventilation Fire inside Mineral wool 165 55 120 60<br />
kg/m3<br />
Ventilation Fire inside Mineral wool 165 70 120 90<br />
kg/m3<br />
Ventilation Fire inside Mineral wool 165 90 240 120<br />
kg/m3<br />
Ventilation Fire Mineral wool 165 30 120 30<br />
outside<br />
kg/m3<br />
Ventilation Fire Mineral wool 165 40 120 60<br />
outside<br />
kg/m3<br />
Ventilation Fire Mineral wool 165 45 120 90<br />
outside<br />
kg/m3<br />
Ventilation Fire Mineral wool 165 50 120 120<br />
outside<br />
kg/m3<br />
Smoke outlet Fire inside Mineral wool 165 40 120 30<br />
kg/m3<br />
Smoke outlet Fire inside Mineral wool 165 55 120 60<br />
kg/m3<br />
Smoke outlet Fire inside Mineral wool 165 70 120 90<br />
kg/m3<br />
Smoke outlet Fire inside Mineral wool 165 90 120 120<br />
kg/m3<br />
Smoke outlet Fire Mineral wool 165 30 120 30<br />
outside<br />
kg/m3<br />
Smoke outlet Fire<br />
outside<br />
Mineral wool 165<br />
kg/m3<br />
40 120 60<br />
Cert.<br />
No.<br />
20 Nov 2011 233
PART 3: SECTION 2<br />
FIRE RESISTANT DUCTS<br />
Product<br />
Name<br />
Duct Type Condition Type / density of<br />
insulation<br />
Smoke outlet<br />
Smoke outlet<br />
Kitchen<br />
extract<br />
Kitchen<br />
extract<br />
Kitchen<br />
extract<br />
Kitchen<br />
extract<br />
Fire<br />
outside<br />
Mineral wool 165<br />
kg/m3<br />
Fire Mineral wool 165<br />
outside<br />
kg/m3<br />
Fire inside Mineral wool 165<br />
kg/m3<br />
Fire inside Mineral wool 165<br />
kg/m3<br />
Fire Mineral wool 165<br />
outside<br />
kg/m3<br />
Fire Mineral wool 165<br />
outside<br />
kg/m3<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
(Integrity/<br />
stability)<br />
Fire<br />
Resistance<br />
(Insulation)<br />
45 120 90<br />
50 120 120<br />
45 120 30<br />
90 120 60<br />
45 120 30<br />
90 120 60<br />
Cert.<br />
No.<br />
Notes:<br />
1. LPCB Ref. No's. 785a/03 and 785a/04 - Uninsulated and Insulated ductwork systems to be manufactured and installed to the<br />
specifications as detailed in BRE Assessment Report CC 255037 Issue 5 dated 8 July 2011.<br />
2. LPCB Ref. No's 785a/03 and 785a/04 - Covers rectangular and flat oval ductwork up to 3000mm wide x 2000mm deep, reference<br />
Flameshield Tables 1 - Issue F & 4 - Issue E and circular ductwork up to 1250mm diameter, reference Flameshield Tables 5 - Issue D<br />
and 6 - Issue D. The Flameshield systems may also be employed as attenuator casings as defined in BRE Assessment Report CC<br />
255037 Issue 5 dated 8 July 2011 however the LPCB approval does not cover the attenuator itself.<br />
4. LPCB Ref. No's 785a/03 and 785/04 - Approval also covers Uninsulated and Insulated ductwork systems manufactured to<br />
Flameshield Table 20 - Issue F for ventilation duct applications only with a fire resistance intergrity and stability period of up to 120<br />
minutes and where applicable, an insulation period as detailed in BRE Assessment Report CC 255037 Issue 5 dated 8 July 2011.<br />
Ductwork manufacturers:<br />
The following Companies manufacture the products listed on this certificate to a specification issued and controlled by Flameshield.<br />
These companies are audited by the LPCB to ensure the product certification requirements are met.<br />
Kent Ductwork Limited (LPCB Ref. 785a(1))<br />
Unit 7/9 Crayford Ind Est<br />
Swaisland Drive<br />
Crayford<br />
Dartford<br />
DA1 4HS<br />
E & S Heating and Ventilation Limited (LPCB Ref. 785a(2))<br />
Diplocks Way<br />
Hailsham<br />
East Sussex<br />
BN27 3JF<br />
Gardner & Co. (Kent) Limited (LPCB Ref. 785a(3))<br />
Unit 2, 23 Revenge Road<br />
Lordswood Industrial Estate<br />
Chatham<br />
Kent<br />
ME5 8UD<br />
Whitehouse Engineering Co. Limited (LPCB Ref. 785a(4))<br />
14 Trench Road<br />
Mallusk<br />
Newtownabbey<br />
Co. Antrim<br />
Northern Ireland<br />
BT36 4UU<br />
Rockwool Limited<br />
Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom<br />
Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302<br />
E-mail: info@rockwool.co.uk • Website: www.rockwool.co.uk<br />
Certificate No: 022f to BS476 : Part 24 : 1987<br />
234 20 Nov 2011
Product Name Duct Type Condition Maximum Duct<br />
size (ht x wt)<br />
(mm)<br />
FirePro Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity<br />
(min)<br />
PART 3: SECTION 2<br />
FIRE RESISTANT DUCTS<br />
Fire Resistance<br />
Insulation<br />
(min)<br />
Cert. No.<br />
Fire Outside 100 x 1000 25 30 30 022f/01<br />
Fire Outside 1000 x 1000 30 60 60<br />
Fire Outside 1500 x 1500 50 90 90<br />
Fire Outside 1500 x 1500 70 120 120<br />
Fire Outside 1525 dia. 25 30 30<br />
Fire Outside 1525 dia. 30 60 60<br />
Fire Outside 1525 dia. 50 90 90<br />
Fire Outside 1525 dia. 70 120 120<br />
Fire Outside 1000 x 1000 25 30 30<br />
Fire Outside 1500 x 1500 40 60 60<br />
Fire Outside 1200 x 1200 70 90 90<br />
Fire Outside 1000 x 1000 90 120 120<br />
Fire Outside 1525 dia. 25 30 30<br />
Fire Outside 1525 dia. 40 60 60<br />
Fire Outside 1525 dia. 70 90 90<br />
Fire Outside 1525 dia. 90 120 120<br />
Fire Inside 1000 x 1000 25 30 30<br />
Fire Inside 1000 x 1000 30 60 60<br />
Fire Inside 1500 x 1500 50 90 90<br />
Fire Inside 1500 x 1500 70 120 120<br />
Fire Inside 1525 dia. 25 30 30<br />
Fire Inside 1525 dia. 30 60 60<br />
Fire Inside 1525 dia. 50 90 90<br />
20 Nov 2011 235
PART 3: SECTION 2<br />
FIRE RESISTANT DUCTS<br />
Product Name Duct Type Condition Maximum Duct<br />
size (ht x wt)<br />
(mm)<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity<br />
(min)<br />
Fire Resistance<br />
Insulation<br />
(min)<br />
Fire Inside 1525 dia. 70 120 120<br />
Fire Inside 1000 x 1000 25 30 30<br />
Fire Inside 1500 x 1500 40 60 60<br />
Fire Inside 1200 x 1200 70 90 90<br />
Fire Inside 1000 x 1000 90 120 120<br />
Fire Inside 1525 dia. 25 30 30<br />
Fire Inside 1525 dia. 40 60 60<br />
Fire Inside 1525 dia. 70 90 90<br />
Fire Inside 1525 dia. 90 120 120<br />
Fire Outside 1000 x 1000 25 30 30<br />
Fire Outside 1000 x 1000 30 60 60<br />
Fire Outside 1500 x 1500 50 90 90<br />
Fire Outside 1500 x 1500 70 120 120<br />
Fire Outside 1525 dia. 25 30 30<br />
Fire Outside 1525 dia. 30 60 60<br />
Fire Outside 1525 dia. 50 90 90<br />
Fire Outside 1525 dia. 70 120 120<br />
Fire Outside 1000 x 1000 25 30 30<br />
Fire Outside 1500 x 1500 40 60 60<br />
Fire Outside 1200 x 1200 70 90 90<br />
Fire Outside 1000 x 1000 90 120 120<br />
Fire Outside 1525 dia. 25 30 30<br />
Fire Outside 1525 dia. 40 60 60<br />
Cert. No.<br />
236 20 Nov 2011
PART 3: SECTION 2<br />
FIRE RESISTANT DUCTS<br />
Product Name Duct Type Condition Maximum Duct<br />
size (ht x wt)<br />
(mm)<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
vertical<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Ventilation<br />
horizontal<br />
orientation<br />
Insulation<br />
Thickness<br />
(mm)<br />
Fire Resistance<br />
Integrity<br />
(min)<br />
Fire Resistance<br />
Insulation<br />
(min)<br />
Fire Outside 1525 dia. 70 90 90<br />
Fire Outside 1525 dia. 90 120 120<br />
Fire Inside 1000 x 1000 25 30 30<br />
Fire Inside 1000 x 1000 30 60 60<br />
Fire Inside 1500 x 1500 50 90 90<br />
Fire Inside 1500 x 1500 70 120 120<br />
Fire Inside 1525 dia. 25 30 30<br />
Fire Inside 1525 dia. 30 60 60<br />
Fire Inside 1525 dia. 50 90 90<br />
Fire Inside 1525 dia. 70 120 120<br />
Fire Inside 1000 x 1000 25 30 30<br />
Fire Inside 1500 x 1500 40 60 60<br />
Fire Inside 1200 x 1200 70 90 90<br />
Fire Inside 1000 x 1000 90 120 120<br />
Fire Inside 1525 dia. 25 30 30<br />
Fire Inside 1525 dia. 40 60 60<br />
Fire Inside 1525 dia. 70 90 90<br />
Fire Inside 1525 dia. 90 120 120<br />
Kitchen extract Fire Outside 1500 x 1500 40 30 30<br />
Kitchen extract Fire Outside 1000 x 1000 90 60 60<br />
Cert. No.<br />
20 Nov 2011 237
PART 3: SECTION 3<br />
SMOKE CURTAINS<br />
Smoke curtains are used:<br />
<br />
<br />
<br />
To create a smoke reservoir by containing and limiting the travel of smoke.<br />
To channel smoke in a predetermined direction.<br />
To prevent or retard smoke entry to another area or void.<br />
All the smoke curtains listed in Section 3 of this <strong>part</strong> of the list have been tested and assessed against the<br />
requirements of LPS 1182 Requirements and tests for fixed fabric smoke curtains, fixed metal smoke curtains<br />
and powered smoke curtains.<br />
238 20 Nov 2011
PART 3: SECTION 4<br />
POWERED SMOKE AND HEAT EXHAUST VENTILATION<br />
Powered smoke and heat exhaust ventilation fans are used:<br />
<br />
<br />
To channel heat and smoke in a predetermined direction.<br />
To prevent smoke logging of the protected space.<br />
All the fans listed have been approved against the requirements of BSEN 12101-3 Smoke and heat control<br />
systems. Part 3 Specification for powered smoke and heat exhaust ventilation.<br />
Elta Fans Limited<br />
17 Barnes Wallis Road, Segensworth East Industrial Estate, Farnham, Hampshire PO15 5ST, United<br />
Kingdom<br />
Tel: +44 (0) 1489 566555 • Fax: +44 (0) 1489 566555<br />
E-mail: mailbox@eltafans.co.uk • Website: www.eltafans.com<br />
Additional Manufacturing Site<br />
46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands DY6 7US, United Kingdom<br />
Certificate No: 937a to BS EN 12101-3: 2002<br />
20 Nov 2011 239
PART 3: SECTION 4<br />
POWERED SMOKE AND HEAT EXHAUST VENTILATION<br />
Product Name Model Application<br />
Classes<br />
SmokeVent axial fan (notes 2, 5, 6, 7,<br />
8)<br />
JetVent Impulse (flanged - standard<br />
thrust) axial fan (notes 2, 5, 6, 7, 8)<br />
LCS025,<br />
LCS031,<br />
LCS035,<br />
LCS040,<br />
LCS045,<br />
LCS050,<br />
LCS056,<br />
LCS063,<br />
LCS071,<br />
LCS080,<br />
LCS090,<br />
LCS100,<br />
LCS112,<br />
LCS125,<br />
LCS140,<br />
LCS160,<br />
LCS180,<br />
LCS200,<br />
SCS025,<br />
SCS031,<br />
SCS035,<br />
SCS040,<br />
SCS045,<br />
SCS050,<br />
SCS056,<br />
SCS063,<br />
SCS071,<br />
SCS080,<br />
SCS090,<br />
SCS100,<br />
SCS112,<br />
SCS125,<br />
SCS140,<br />
SCS160,<br />
SCS180,<br />
SCS200,<br />
LCSCR025,<br />
LCSCR031,<br />
LCSCR035,<br />
LCSCR040,<br />
LCSCR045,<br />
LCSCR050,<br />
LCSCR056,<br />
LCSCR063,<br />
LCSCR071,<br />
LCSCR080,<br />
LCSCR090,<br />
LCSCR100,<br />
LCSCR112,<br />
LCSCR125,<br />
LCSCR140,<br />
LCSCR160,<br />
LCSCR180,<br />
LCSCR200<br />
JFSU-CPA-315<br />
2/4-3,<br />
JFSU-CPA-400<br />
2/4-3,<br />
JFSU-CPA-400<br />
2-3,<br />
JFSR-CPA-315<br />
2/4-3,<br />
JFSR-CPA-400<br />
2/4-3,<br />
JFSR-CPA-400<br />
2-3<br />
insulated or<br />
uninsulated;<br />
smoke reservoir or<br />
non smoke<br />
reservoir; dual<br />
purpose or<br />
emergency use<br />
insulated or<br />
uninsulated;<br />
smoke reservoir or<br />
non smoke<br />
reservoir;<br />
dual purpose or<br />
emergency use<br />
Response<br />
delay<br />
Resistance<br />
to fire<br />
class<br />
Motor<br />
temp.<br />
rating1<br />
N/A F200 Class F<br />
/<br />
Class H<br />
N/A F200 Class F<br />
/<br />
Class H<br />
Cert.<br />
No.<br />
937a/01<br />
240 20 Nov 2011
PART 3: SECTION 4<br />
POWERED SMOKE AND HEAT EXHAUST VENTILATION<br />
Product Name Model Application<br />
Classes<br />
JetVent Impulse (flanged - enhanced<br />
thrust) axial fan (notes 2, 5, 6, 7, 8)<br />
SmokeVent axial fan (notes 2, 5, 6, 7,<br />
8)<br />
LCS031-CPU<br />
2/4-3,<br />
LCS035-CPU<br />
2/4-3,<br />
LCS040-CPU<br />
2/4-3,<br />
LCS031-CPR<br />
2/4-3,<br />
LCS035-CPR<br />
2/4-3,<br />
LCS040-CPR<br />
2/4-3<br />
LCS025,<br />
LCS031,<br />
LCS035,<br />
LCS040,<br />
LCS045,<br />
LCS050,<br />
LCS056,<br />
LCS063,<br />
LCS071,<br />
LCS080,<br />
LCS090,<br />
LCS100,<br />
LCS112,<br />
LCS125,<br />
LCS140,<br />
LCS160,<br />
LCS180,<br />
LCS200,<br />
SCS025,<br />
SCS031,<br />
SCS035,<br />
SCS040,<br />
SCS045,<br />
SCS050,<br />
SCS056,<br />
SCS063,<br />
SCS071,<br />
SCS080,<br />
SCS090,<br />
SCS100,<br />
SCS112,<br />
SCS125,<br />
SCS140,<br />
SCS160,<br />
SCS180,<br />
SCS200,<br />
LCSCR025,<br />
LCSCR031,<br />
LCSCR035,<br />
LCSCR040,<br />
LCSCR045,<br />
LCSCR050,<br />
LCSCR056,<br />
LCSCR063,<br />
LCSCR071,<br />
LCSCR080,<br />
LCSCR090,<br />
LCSCR100,<br />
LCSCR112,<br />
LCSCR125,<br />
LCSCR140,<br />
LCSCR160,<br />
LCSCR180,<br />
LCSCR200<br />
insulated or<br />
uninsulated;<br />
smoke reservoir or<br />
non smoke<br />
reservoir;<br />
dual purpose or<br />
emergency use<br />
insulated or<br />
uninsulated;<br />
smoke reservoir or<br />
non smoke<br />
reservoir;<br />
dual purpose or<br />
emergency use<br />
Response<br />
delay<br />
Resistance<br />
to fire<br />
class<br />
Motor<br />
temp.<br />
rating1<br />
N/A F200 Class F<br />
/<br />
Class H<br />
N/A F300 4 Class F<br />
/<br />
Class H<br />
Cert.<br />
No.<br />
937a/02<br />
20 Nov 2011 241
PART 3: SECTION 4<br />
POWERED SMOKE AND HEAT EXHAUST VENTILATION<br />
Product Name Model Application<br />
Classes<br />
JetVent impulse (flanged - standard<br />
thrust) axial fan (notes 2, 5, 6, 7, 8)<br />
JetVent impulse (flanged - enhanced<br />
thrust) axial fan (notes 2, 5, 6, 7, 8)<br />
SmokeVent axial fan (notes 2, 5, 6, 7,<br />
8)<br />
JetVent centrifugal (Mark I) fan (notes<br />
3, 5, 8)<br />
JFSU-CPA-315<br />
2/4-3,<br />
JFSU-CPA-400<br />
2/4-3,<br />
JFSU-CPA-400<br />
2-3,<br />
JFSR-CPA-315<br />
2/4-3,<br />
JFSR-CPA-400<br />
2/4-3,<br />
JFSR-CPA-400<br />
2-3<br />
LCS031-CPU<br />
2/4-3,<br />
LCS035-CPU<br />
2/4-3,<br />
LCS040-CPU<br />
2/4-3,<br />
LCS031-CPR<br />
2/4-3,<br />
LCS035-CPR<br />
2/4-3,<br />
LCS040-CPR<br />
2/4-3<br />
LCS025,<br />
LCS031,<br />
LCS035,<br />
LCS040,<br />
LCS045,<br />
LCS050,<br />
LCS056,<br />
LCS063,<br />
LCS071,<br />
LCS080,<br />
LCS090,<br />
LCS100,<br />
LCS112,<br />
LCS125,<br />
SCS025,<br />
SCS031,<br />
SCS035,<br />
SCS040,<br />
SCS045,<br />
SCS050,<br />
SCS056,<br />
SCS063,<br />
SCS071,<br />
SCS080,<br />
SCS090,<br />
SCS100,<br />
SCS112,<br />
SCS125,<br />
LCSCR025,<br />
LCSCR031,<br />
LCSCR035,<br />
LCSCR040,<br />
LCSCR045,<br />
LCSCR050,<br />
LCSCR056,<br />
LCSCR063,<br />
LCSCR071,<br />
LCSCR080,<br />
LCSCR090,<br />
LCSCR100,<br />
LCSCR112,<br />
LCSCR125<br />
JISU-CPC-50N,<br />
JISU-CPC-100N,<br />
insulated or<br />
uninsulated;<br />
smoke reservoir or<br />
non smoke<br />
reservoir;<br />
dual purpose or<br />
emergency use<br />
insulated or<br />
uninsulated;<br />
smoke reservoir or<br />
non smoke<br />
reservoir;<br />
dual purpose or<br />
emergency use<br />
insulated or<br />
uninsulated;<br />
smoke reservoir or<br />
non smoke<br />
reservoir;<br />
dual purpose or<br />
emergency use<br />
uninsulated;<br />
smoke reservoir;<br />
dual purpose or<br />
emergency use<br />
Response<br />
delay<br />
Resistance<br />
to fire<br />
class<br />
Motor<br />
temp.<br />
rating1<br />
N/A F300 4 Class F<br />
/<br />
Class H<br />
N/A F300 4 Class F<br />
/<br />
Class H<br />
N/A F400 Class F<br />
/<br />
Class H<br />
N/A F300 Class F<br />
/<br />
Class H<br />
Cert.<br />
No.<br />
937a/03<br />
937a/04<br />
242 20 Nov 2011
PART 3: SECTION 4<br />
POWERED SMOKE AND HEAT EXHAUST VENTILATION<br />
Product Name Model Application<br />
Classes<br />
JetVent -centrifugal (Mark II) fan<br />
(notes 3, 5, 8)<br />
JetVent impulse (unflanged -<br />
standard thrust) axial fan (notes3, 5,<br />
8)<br />
JISU-2-CPC-<br />
50N,<br />
JISU-2-CPC-<br />
100N,<br />
JVSU-CPA-315<br />
2/4-3,<br />
JVSU-CPA-400<br />
2-3,<br />
JVSU-CPA-400<br />
2/4-3,<br />
JVSR-CPA-315<br />
2/4-3,<br />
JVSR-CPA-400<br />
2-3<br />
JVSR-CPA-400<br />
2/4-3<br />
uninsulated;<br />
smoke reservoir;<br />
dual purpose or<br />
emergency use<br />
uninsulated; smoke<br />
reservoir;<br />
dual purpose or<br />
emergency use<br />
Response<br />
delay<br />
Resistance<br />
to fire<br />
class<br />
Motor<br />
temp.<br />
rating1<br />
N/A F300 4 Class F<br />
/<br />
Class H<br />
N/A F300 4 Class F<br />
/<br />
Class H<br />
Cert.<br />
No.<br />
937a/05<br />
937a/06<br />
Notes:<br />
1. Motor temperature rating - classes given refer to temperature rise at ambient and motor insulation as detailed in <strong>section</strong> 4.2 of EN<br />
12101-3: 2002.<br />
2. Both horizontal and vertical installation is permitted.<br />
3. Horizontal installation only is permitted.<br />
4. Tested to 300°C for 120 minutes.<br />
5. Only certified accessories should be used.<br />
6. Use of guide vanes is permitted. Where this is the case the model code has +GV added, e.g. LCS025+GV.<br />
7. Fan coding of units held within Select stock will be prefixed by the letter ‘S’, and the size expressed in mm (i.e. LCS025 becomes<br />
SLCS250)<br />
8. No ducted cooling air is required.<br />
20 Nov 2011 243
PART 3: SECTION 5<br />
GREASE FILTERS USED IN COMMERCIAL KITCHEN EXTRACT SYSTEMS<br />
LPS 1263 Requirements for the LPCB Approval and Listing of the Fire Performance of Grease Filters Used in<br />
Commercial Extract systems.<br />
This standard covers the test procedures and method of calculating the fire performance rating of grease<br />
filters used for the reduction of flammable and volatile grease droplets from the cooking exhaust of<br />
commercial cooking equipment in such situations as restaurant kitchens, canteens or similar food preparation<br />
areas where it is necessary to reduce the cooking exhause via a ventilation system.<br />
Halton Foodservice Limited<br />
11 Laker Road, Airport Industrial Estate, Rochester, Kent ME1 3QX, United Kingdom<br />
Tel: +44 (0)1634 666111 • Fax: +44 (0)1634 666333<br />
E-mail: kelly.hiley@halton.com • Website: www.halton.com/foodservice<br />
Certificate No: 996a to LPS 1263 issue 1.2<br />
Product Name<br />
Nominal<br />
filter size<br />
(w x h x t) (mm)<br />
Nominal<br />
flow rate<br />
(m 3 /h)<br />
LPS 1263 Grade<br />
Cert. No.<br />
KSA Filter 498 x 330 x 51.6 786 GF90 996a/01<br />
Notes:<br />
1. LPCB ref 996a/01 The KSA filter is manufactured from Grade 304 S16 stainless steel with 0.4mm thick filter fins and 0.8mm casing.<br />
2. LPCB ref 996a/01 KSA filter is approved as <strong>part</strong> of a Kitchen Ventilation system with 400, 555 and 555UV canopy profiles only.<br />
244 20 Nov 2011
Part<br />
4<br />
SECURITY PROTECTION<br />
PRODUCTS
PART 4: SECURITY PROTECTION PRODUCTS<br />
INTRODUCTION<br />
Security products and services approved by LPCB play an important role in protecting people and property<br />
against physical attack, burglary, vandalism and terrorism.<br />
Statistics from the UK indicate that the addition of appropriate security measures to a home reduces the risk<br />
of burglary from 25% to 2.4%. However, it is important that the measures installed are effective. LPCB<br />
approval ensures that products developed for use in domestic applications offer effective levels of deterrence<br />
and, when required, will resist determined attack by a criminal wishing to gain access to a property.<br />
The threat to organisations from commercial crime and terrorism is diverse in both geography and levels of<br />
skill involved, it is persistent and requires appropriate measures to deter criminals and terrorists. Improved<br />
detection backed up by a fast and effective response, and effective physical security that provides a suitable<br />
delay while the response arrives, reduces the likelihood of such act being committed. This is supported by<br />
research and initiatives, in the UK, LPCB works closely with Insurers, Government, Police, end users and<br />
security equipment specifiers to develop methods by which the quality of product performance and product<br />
reliability can be assessed. Using security products approved by LPCB to protect people and assets is an<br />
effective way of mitigating many of the risks associated with crime and terrorism.<br />
The products listed in this <strong>section</strong> have been rigorously tested in programmes designed to evaluate resistance<br />
to deliberate attack.<br />
The scope of the approval of each product is described in the relevant <strong>section</strong> and on the certificates issued to<br />
the approved manufacturer. It is important to ensure that specifiers only select products covered by the scope<br />
detailed on the certificate since products outside that scope may not provide an equivalent level of security.<br />
The range of products listed in this <strong>section</strong> is extensive and includes physical barrier type products, asset<br />
marking, computer protection equipment as well as electronic detection and surveillance equipment. The<br />
range and scope of products submitted for approval continues to grow significantly.<br />
Products are approved in accordance with a range of standards. The details of these standards are given at<br />
the front of each <strong>section</strong> relevant to the product.<br />
246 20 Nov 2011
PART 4: SECTION 1.1<br />
INTRUDER DETECTION EQUIPMENT<br />
This <strong>section</strong> lists components of intruder detection systems where compliance with the applicable EN 50131<br />
series of standards has been demonstrated by LPCB’ experts and most importantly on going assessments<br />
confirm the component continues to comply with the requirements.<br />
The LPCB’s intruder detection approval schemes reference Loss Prevention Standards LPS 1602 and LPS<br />
1603 which incorporate the requirements of the corresponding EN 50131 series of standards. The Loss<br />
Prevention Standards also include specific checks to confirm the intruder detection components are suitable<br />
for use in installations complying with the United Kingdom’s document PD 6662 Scheme for the application of<br />
European Standards for intruder and hold-up alarm systems and the confirmation technology requirements of<br />
BS 8243 in support of the ACPO security systems policy.<br />
By obtaining LPCB approval to the relevant LPS, conformance to the applicable requirements of the various<br />
European standards, published documents, and policies can be demonstrated.<br />
Control and Indicating Equipment<br />
LPS 1603 Requirements for LPCB Approval and Listing of Intruder Alarm Control and Indicating Equipment is<br />
the standard used for the certification of security system control and indicating equipment. The purpose of this<br />
LPS is to list requirements of the performance and suitability for use in installations complying with the United<br />
Kingdom’s document PD 6662 Scheme for the application of European Standards for intruder and hold-up<br />
alarm systems.<br />
The requirements are based on the criteria described in the European Standard EN 50131-3 and where<br />
appropriate to the criteria of BS 8243 in support of the ACPO security systems policy.<br />
Intruder Alarm Movement Detectors<br />
LPS 1602 Requirements for LPCB Approval and Listing of Intruder Alarm Movement Detectors is the standard<br />
used for the certification of intruder alarm movement detectors. This Loss Prevention Standard specifies the<br />
requirements for LPCB approval of the following types of intruder alarm movement detectors;<br />
<br />
<br />
<br />
<br />
Passive infrared<br />
Microwave<br />
Combined passive infrared and microwave<br />
Combined passive infrared and ultrasonic<br />
The purpose of this LPS is to list requirements of the performance of intruder alarm movement detectors and<br />
their suitability for use in installations complying with United Kingdom’s document PD 6662 ‘Scheme for the<br />
application of European Standards for intruder and hold-up alarm systems’. The requirements are based on<br />
the criteria described in the European Standards of EN 50131-2-2, EN 50131-2-3, EN 50131-2-4 and EN<br />
50131-2-5 respectively and to the criteria of BS 8243 in support of the ACPO security systems policy.<br />
LPCB approval to this LPS is applicable only to intruder alarm movement detectors intended for mounting<br />
inside the premises i.e. not externally located.<br />
Note: At the time of going to print no intruder detection equipment was listed as LPCB approved. Please<br />
check www.redbooklive.com for updates.<br />
20 Nov 2011 247
PART 4: SECTION 1.2<br />
ALARM TRANSMISSION EQUIPMENT AND SIGNALLING SYSTEMS<br />
This <strong>section</strong> lists alarm transmission equipment suitable for use with intruder alarm and hold-up systems.<br />
Alarm transmission and fault warning routing equipment suitable for use with fire alarm systems is listed in<br />
Volume 1 Part 1 Section 10.1.<br />
Where alarm transmission equipment is suitable for use with both intruder alarm and hold-up systems and fire<br />
alarm systems, the entry for the approved equipment will appear in Volume 2 Part 4 Section 1.2 and Volume 1<br />
Part 1 Section 10 of the Red Book.<br />
The following standard is currently used for the approval scheme:<br />
• LPS 1277 Requirements for LPCB Approval and listing of Alarm Transmission Systems and Equipment<br />
Where appropriate within LPS 1277, reference has been made to published standards for intruder alarm and<br />
hold-up systems including EN 50131-1 together with the alarm transmission equipment standards of EN<br />
50136.<br />
Particular emphasis is placed on the verification of manufacturers’ claims by measuring alarm transmission<br />
times over the transmission path(s) between the equipment under test and the corresponding receiving<br />
centre. The response to the reporting of fault conditions is measured in a similar way.<br />
The results of these measurements are expressed in terms of alarm transmission system (ATS) performance<br />
criteria classification, using the parameters D, M, T and where applicable S and I.<br />
Where:<br />
D = Transmission time classification<br />
M = Transmission time maximum values<br />
T = Reporting time classification<br />
S = Substitution Security<br />
I = Information Security<br />
Availability is considered a key parameter under LPCB approval and is therefore included within the<br />
requirements of LPS 1277 and the resultant performance is expressed using the parameter ‘A’ for Availability.<br />
The measured parameters are used to determine the performance classification in terms of ATS level (1 to 6)<br />
that when used in conjunction with warning devices provide the security grade of the intrusion and hold-up<br />
alarm system (I&HAS) as defined in EN 50131-1.<br />
Products compliant with LPS 1277 Issue 3.0 meet ‘enhanced’ ATS performance classification which includes<br />
timed ‘stepped up’ reporting after the loss of the primary path and the reporting of a catastrophic failure, in<br />
event of the simultaneous loss of multiple transmission paths.<br />
To assist specifiers in their selection of the products most appropriate for protecting their risks, the actual<br />
performance parameters measured during the LPCB test programme are included with the product<br />
listing entry in the Redbook as an indicator of the level of performance that can be expected from the alarm<br />
transmission system.<br />
Compliance with relevant safety standards and applicable mandatory directives is a<br />
pre-requisite of LPCB approval and listing. Regular product auditing and regular factory inspections are<br />
carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable<br />
product standard.<br />
Note<br />
Since LPCB uses national and international standards for the listing of products, in some instances, the<br />
requirements of these standards may conflict with the recommendations of local codes of practice. We<br />
recommend that specifiers seek advice from the relevant local authorities and amend their specifications<br />
accordingly.<br />
248 20 Nov 2011
PART 4: SECTION 1.2.1<br />
ALARM TRANSMISSION EQUIPMENT AND SYSTEMS<br />
The equipment listed in this <strong>section</strong> has been assessed against the requirements and tests methods of LPS<br />
1277 Requirements for LPCB Approval and listing of Alarm Transmission Systems and Equipment.<br />
Those components of the alarm transmission system normally located in the protected premises are listed.<br />
The alarm transmission and fault monitoring performance has been verified by testing the alarm transmission<br />
equipment in conjunction with the appropriate transmission networks.<br />
Specifiers are advised to check the product listing for the issue of LPS 1277 against which the alarm<br />
transmission equipment is approved. At the time of going to print, the current publication of LPS 1277 was<br />
Issue 3.0.<br />
Please check www.redbooklive.com for the current publication and the latest product listings.<br />
BT Redcare<br />
Monument TE, 11-13 Great Tower Street, London EC3R 5EA, United Kingdom<br />
Tel: +44 (0) 800 800 828 • Fax: +44 (0)20 7929 6490<br />
Website: www.redcare.bt.com<br />
Certificate No: 775a to LPS 1277: Issue <strong>2.2</strong><br />
Alarm Transmission Equipment<br />
Product Name Fire<br />
Category<br />
Security<br />
Grade<br />
Primary Transmission<br />
Path<br />
UC-372G-UK B 3 Asynchronous digital subscriber line<br />
ASSURE STAR<br />
(ASDL) operated by BT Broadband<br />
Secondary<br />
Transmission Path<br />
General packet radio service<br />
(GPRS) on a BT mobile network<br />
Cert.<br />
No.<br />
775a/01<br />
Performance Parameters<br />
Transmission<br />
Path<br />
Transmission<br />
Time<br />
Classification<br />
Transmission<br />
Time<br />
Max. Values<br />
Reporting Time<br />
Classification<br />
Substitution<br />
Security<br />
Information<br />
Security<br />
Network<br />
Availability 5<br />
Primary D4 M3 2 T5 S2 I3 A3<br />
Secondary D4 M3 2 T3 3 S2 I3 A1<br />
Combined 1 D4 M3 2 T5 4 S2 I3 A3<br />
Approved Ancillaries<br />
AO100 External base antenna (short)<br />
BA900-5 High gain antenna (long)<br />
CAB0106 10m low loss extension cable<br />
UltraCapture8 Video Card<br />
UltraCapture4 Video Card<br />
Notes:<br />
1. The combined performance parameters are shown for the ASSURE STAR as a whole, i.e. with both primary and secondary<br />
transmission paths operational. The alarm transmission performance parameters of the ASSURE STAR are consistent with those of<br />
ATS 5.<br />
2. During a planned maintenance procedure the ASSURE STAR will achieve performance classification D4 at a maximum transmission<br />
time classification M2. The maintenance procedure will be operated approximately four times per year and will be of approximately 5<br />
minutes duration.<br />
3. The loss of the secondary path following a previous failure of the primary path results in a reporting time classification of T4.<br />
4. The simultaneous loss of the primary and secondary transmission paths results in a reporting time classification of T5.<br />
5. Network availability classifications have been based on the limited availability data. At the time of the initial evaluation only a limited<br />
number of ASSURE STAR alarm transmission equipment were in service and these were subject to interruption due to engineering<br />
trials whilst the data was being recorded. The monitoring of network availability continues and the classification will be updated when<br />
available. When operating with both transmission paths functioning correctly the combined system availability will meet classification<br />
A3.<br />
20 Nov 2011 249
PART 4: SECTION 1.2.1<br />
ALARM TRANSMISSION EQUIPMENT AND SYSTEMS<br />
WebWayOne Ltd<br />
11 Kingfisher Court, Hambridge Road, Newbury, Berkshire RG14 5SJ, United Kingdom<br />
Tel: +44 (0)1635 231500 • Fax: +44 (0)1635 231539<br />
E-mail: sales@webwayone.co.uk • Website: www.webwayone.co.uk<br />
Certificate No: 1022b to LPS 1277: Issue 3.0<br />
Alarm Transmission Equipment<br />
Certificated Products<br />
22-5005 WebWay<br />
The WebWay IP/GPRS LPS I&HAS comprises equipment <strong>part</strong> no. 22-5005 plus<br />
IP/GPRS LPS I&HAS configuration <strong>part</strong> no. '1411AD155002'<br />
Suitable for use with EN 50131-1 compliant I&HAS up to and including security grade 4,<br />
22-5015 WebWay<br />
GPRS/PSTN LPS I&HAS<br />
notification Option C.<br />
The WebWay GPRS/PSTN LPS I&HAS comprises equipment <strong>part</strong> no. 22-5015 plus<br />
configuration <strong>part</strong> no. '1411AD155004'<br />
Suitable for use with EN 50131-1 compliant I&HAS up to and including security grade 3,<br />
notification Option C.<br />
Cert. No.<br />
1022b/01<br />
1022b/02<br />
Approved with the following Ancillaries<br />
22-5054 High performance disc antenna<br />
22-5049-5m High gain extension antenna with 5 metre cable<br />
22-5049-10m High gain extension antenna with 10 metre cable<br />
22-5049-15m High gain extension antenna with 15 metre cable<br />
22-5049-20m High gain extension antenna with 20 metre cable<br />
22-5076 PSTN Dialler PCB module<br />
22-5073 RS232 Serial interface module<br />
22-5076 Modem capture alarm panel interface module<br />
The alarm transmission equipment is to be used in accordance with the installation instructions and the guidance of ANNEX C described<br />
in LPS 1277 Issue 3.0 ‘Requirements for LPCB Approval and Listing of Alarm Transmission Equipment’.<br />
The performance of the above listed products has been found to meet the intrusion and hold-up alarm requirements of LPS 1277 Issue<br />
3.0 with the following performance parameters:<br />
Alarm Transmission System Performance Parameters<br />
22-5005 Webway IP/GPRS LPS I&HAS<br />
Product Name<br />
Fire Category<br />
LPCB<br />
Performance<br />
Classification<br />
Designated Transmission Paths<br />
Primary Secondary Duplicate<br />
Cert No<br />
WebWay<br />
IP/GPRS LPS<br />
I&HAS<br />
N/A<br />
Dual Path<br />
Enhanced<br />
ATS 5<br />
Broadband<br />
(IP)<br />
GPRS N/A 1022b/01<br />
Confirmed Performance Parameters<br />
Transmission<br />
time<br />
Classification 1)<br />
Transmission<br />
time<br />
Max. Values 1)<br />
Reporting time<br />
Classification<br />
Substitution<br />
Security 1)<br />
Information<br />
Security 1)<br />
Netw ork<br />
Availability 2)<br />
Enhanced<br />
Performance<br />
Rating<br />
D4 M3 T4 S2 I3 A4 ATS 5<br />
1)<br />
Minimum performance parameters for primary or secondary path.<br />
2) Network Availability confirmed with both designated primary and secondary paths operating.<br />
ATS path failure<br />
250 20 Nov 2011
PART 4: SECTION 1.2.1<br />
ALARM TRANSMISSION EQUIPMENT AND SYSTEMS<br />
ATS path failure conditions<br />
Loss of Primary path only<br />
(i.e. secondary path remaining operational)<br />
Loss of Secondary path only<br />
(i.e. primary path remaining operational)<br />
Loss of Secondary path w hilst operating in ‘stepped up’ reporting mode<br />
(i.e. the loss of Secondary path some time after a previous loss of the Primary path).<br />
Reporting catastrophic 3) failure of ATS commensurate w ith<br />
Reporting Time<br />
Classification<br />
T4<br />
T3<br />
T4<br />
Enhanced<br />
ATS 5<br />
3) The detected loss of the primary path followed by immediate detection of loss of the Secondary path.<br />
__________________________________________________________________________________________<br />
22-5015 Webway GPRS/PSTN LPS I&HAS<br />
Product Name<br />
Fire Category<br />
LPCB<br />
Performance<br />
Classification<br />
Designated Transmission Paths<br />
Primary Secondary Duplicate<br />
Cert No<br />
WebWay<br />
GPRS/PSTN<br />
LPS I&HAS<br />
N/A<br />
Dual Path<br />
Enhanced GPRS PSTN N/A 1022b/02<br />
ATS 4 Plus<br />
Confirmed Performance Parameters<br />
Transmission<br />
time<br />
Classification 1)<br />
Transmission<br />
time<br />
Max. Values 1)<br />
Reporting time<br />
Classification<br />
Substitution<br />
Security 1)<br />
Information<br />
Security 1)<br />
Netw ork<br />
Availability 2)<br />
Enhanced<br />
Performance<br />
Rating<br />
D3 M3 T3 Plus S2 I3 A4 ATS 4 Plus<br />
1)<br />
Minimum performance parameters for primary or secondary path.<br />
2) Network Availability confirmed with both designated primary and secondary paths operating.<br />
ATS path failure<br />
ATS path failure conditions<br />
Loss of Primary path only<br />
(i.e. secondary path remaining operational)<br />
Loss of Secondary path only<br />
(i.e. primary path remaining operational)<br />
Loss of Secondary path w hilst operating in ‘stepped up’ reporting mode<br />
(i.e. the loss of Secondary path some time after a previous loss of the Primary path).<br />
Reporting catastrophic 3) failure of ATS commensurate w ith<br />
Reporting Time<br />
Classification<br />
T 3 Plus<br />
T3<br />
T3 Plus<br />
Enhanced<br />
ATS 4 Plus<br />
3) The detected loss of the primary path followed by immediate detection of loss of the Secondary path.<br />
20 Nov 2011 251
PART 4: SECTION 2<br />
SAFES, STRONGROOMS AND SECURE SAFE CABINETS<br />
This <strong>section</strong> lists safes, strongrooms and secure safe cabinets that have been designed for the secure<br />
storage of cash and valuables, but which may also be used to secure other high risk assets, including secure<br />
information.<br />
The safes, strongrooms and security cabinets listed are graded according to their resistance to manual<br />
intervention attack tests. These are undertaken by experienced laboratory test engineers using tools carefully<br />
selected to achieve access to the contents of the safe using the minimum time and resistance units possible.<br />
Domestic safes and those typically fitted in hotel bedrooms are generally graded in accordance with EN<br />
14450 Secure Storage units - Requirements, classification and methods of test for resistance to burglary -<br />
Secure safe cabinets.<br />
Commercial safes and strongrooms are either graded in accordance with LPS 1183 Specification for safe<br />
storage units. Part 1: Safes and strongrooms or<br />
EN 1143-1 Secure storage units. Requirements, classification and methods of test for resistance to burglary.<br />
Safes, strongroom doors and strongrooms.<br />
Deposit safes are graded in accordance with EN 1143-2 Secure storage units. Requirements, classification<br />
and methods of test for resistance to burglary. Deposit systems.<br />
Cash and Jewellery Ratings<br />
Table 1 indicates typical cash and jewellery ratings attributed to safes and strongrooms according to their<br />
approved resistance grade. These ratings should only be used as a guide since each insurer defines their<br />
own ratings depending on the performance of the safes and the situation in which the safes and strongrooms<br />
are to be used. Specifiers are strongly advised to discuss the issue of cash and jewellery ratings with their<br />
insurer prior to selecting a safe or strongroom.<br />
Table 1: Typical Cash and Jewellery Ratings for Safes and Strongrooms<br />
Standard Resistance grade Typical overnight cash<br />
rating (£k)<br />
Typical overnight<br />
jewellery rating (£k)<br />
EN 14450<br />
S1 2 20<br />
S2 4 40<br />
LPS 1183 and EN 1143-1<br />
0 6 60<br />
I 10 100<br />
II 17.5 175<br />
III 35 350<br />
IV 60 600<br />
V 100 1000<br />
VI 150 1500<br />
VII to XIII - -<br />
Compatible Locks<br />
The locks that have been approved for use on each of the approved safes and strongrooms are listed in the<br />
'compatible locks' <strong>section</strong> of each manufacturer’s entry in the Red Book. Specifiers and end users are advised<br />
that the performance of the safes to the relevant standards is dependent on them being fitted with the locks<br />
listed.<br />
Installation and maintenance<br />
It is important to ensure that safes are installed in accordance with the manufacturer’s instructions and that all<br />
exposed fixings, the substrate into which the device is fitted and the locking mechanisms are regularly<br />
checked to ensure that they are in good condition and that they have not been tampered with.<br />
252 20 Nov 2011
PART 4: SECTION 2.1<br />
SAFES<br />
The safes listed in this <strong>section</strong> are approved by LPCB to one or more of the following standards:<br />
EN 1143-1 Secure storage units. Requirements, classification and methods of test for resistance to<br />
burglary. Safes, strongroom doors and strongrooms.<br />
LPS 1183 Specification for safe storage units. Part 1: Safes and strongrooms<br />
Copies of LPS 1183 can be downloaded free of charge from our website www.<strong>RedBookLive</strong>.com.<br />
Explosion (EX) Designation<br />
This designation indicates a product offers resistance to detonation of a PETN (Pentaerythritol tetranitrate)<br />
explosive charge followed by post detonation tool attacks aimed at achieving entry to the safe. Where the use<br />
of explosive charges is perceived to be a threat it is recommended products with this designation are<br />
selected.<br />
Core Drill (CD) Designation<br />
This designation is only applicable to safes achieving grades IV and above. This designation reflects the<br />
ability of a product to pass the diamond drill test specified within EN 1143-1 which is designed to demonstrate<br />
the product’s superior resistance to methods of forced entry that solely involve the use of diamond core drills.<br />
Dudley Safes Limited<br />
Unit 17 Deepdale Works, Deepdale Lane, Upper Gornal, Dudley, West Midlands DY3 2AF, United Kingdom<br />
Tel: +44 (0)1384 239991 • Fax: +44 (0)1384 455129<br />
Website: www.dudleysafes.com<br />
Certificate No: 304a to LPS 1183: Issue 4 and BS EN 1143-1: 2005<br />
Free-standing Safes<br />
Product Name Size Reference Security<br />
Cert. No.<br />
Grade<br />
Europa 0 1 to 7 0 304a/01<br />
Europa I 1 to 7 I 304a/02<br />
Europa II 1 to 7 II 304a/03<br />
Europa III 2 to 7 III 304a/04<br />
Europa II (Mk.2) 1 to 7 II 304a/05<br />
Europa 0 (Mk.2) 1 to 7 0 304a/06<br />
Europa I (Mk.2) 1 to 7 I 304a/07<br />
Europa III (Mk. 2) 2 to 7 III 304a/08<br />
Compatible Locks<br />
20 Nov 2011 253
PART 4: SECTION 2.1<br />
SAFES<br />
Model Type Europa Safe (LPCB Ref. No. 304a/..)<br />
01 02 03 04 05 06 07 08<br />
Auditcon 52 Electronic Combination <br />
Caw i 2648 Mechanical Key <br />
Kaba 252 Electronic Combination <br />
Kaba 525 Electronic Combination <br />
Kaba MAS 552 Electronic Combination <br />
LaGard 1985 Mechanical Combination <br />
LaGard 3330 Mechanical Combination <br />
LaGard 3740 Electronic Combination <br />
LaGard Combogard 33E Electronic Combination <br />
LaGard Combogard 39E Electronic Combination <br />
LaGard Combogard 66E Electronic Combination <br />
M-Locks EM3520 Electronic Combination <br />
M-Locks EM3550 Electronic Combination <br />
Mauer 70079 Mechanical Key <br />
Mauer 71111 Mechanical Key <br />
Opus 060/EM25.20 Electronic Combination <br />
S&G 6730 Mechanical Combination <br />
S&G 6731 Mechanical Combination <br />
Godrej & Boyce Mfg. Co. Ltd. (Security Equipment Division)<br />
Plant - 17, Pirojshanagar, Vikhroli, Mumbai 400 079, India<br />
Tel: +91 22 679 64771 • Fax: +91 22 679 61509<br />
E-mail: securityexports@godrej.com or secure@godrej.com • Website: www.godrej.com<br />
Certificate No: 954b to BS EN 1143-1: 2005 + A1: 2009 and LPS 1183: Issue 4<br />
Free-standing Safes<br />
Product Name<br />
Euro Cash Grade<br />
3<br />
Euro Cash Grade<br />
4<br />
Euro Cash Grade<br />
5<br />
Size<br />
Ref:<br />
Minimum<br />
External<br />
Height<br />
(mm)<br />
Maximum<br />
External<br />
Height<br />
(mm) 1<br />
Minimum<br />
External<br />
Width<br />
(mm)<br />
Maximum<br />
External<br />
Width<br />
(mm) 1<br />
Minimum<br />
External<br />
Depth<br />
(mm)<br />
Maximum<br />
External<br />
Depth<br />
(mm) 1<br />
Nominal<br />
Weight<br />
(kg)<br />
Security<br />
Grade<br />
Cert.<br />
No.<br />
T14 485 - 485 - 498 - 173 III 954b/01<br />
T19 615 - 435 - 498 - 185 III<br />
T23 715 - 550 - 648 - 285 III<br />
T28 830 - 580 - 673 - 337 III<br />
T35 1030 - 640 - 748 - 453 III<br />
T43 1230 - 640 - 748 - 530 III<br />
T51 1430 - 630 - 748 - 600 III<br />
T63 1730 - 800 - 693 - 768 III<br />
T70 1900 - 860 - 748 - 903 III<br />
F23 715 - 550 - 648 - 397 IV 954b/02<br />
F28 830 - 580 - 673 - 462 IV<br />
F35 1030 - 640 - 748 - 618 IV<br />
F43 1230 - 640 - 748 - 727 IV<br />
F51 1430 - 640 - 748 - 892 IV<br />
F63 1730 - 800 - 693 - 1092 IV<br />
F70 1900 - 860 - 748 - 1307 IV<br />
P23 715 - 550 - 648 - 397 V 954b/03<br />
P28 830 - 580 - 673 - 462 V<br />
P35 1030 - 640 - 748 - 618 V<br />
P43 1230 - 640 - 748 - 727 V<br />
P51 1430 - 640 - 748 - 892 V<br />
P63 1730 - 800 - 693 - 1092 V<br />
P70 1900 - 860 - 748 - 1307 V<br />
254 20 Nov 2011
PART 4: SECTION 2.1<br />
SAFES<br />
Product Name<br />
Euro Cash Grade<br />
6<br />
Euro Cash Grade<br />
0<br />
Euro Cash Grade<br />
1<br />
Size<br />
Ref:<br />
Minimum<br />
External<br />
Height<br />
(mm)<br />
Maximum<br />
External<br />
Height<br />
(mm) 1<br />
Minimum<br />
External<br />
Width<br />
(mm)<br />
Maximum<br />
External<br />
Width<br />
(mm) 1<br />
Minimum<br />
External<br />
Depth<br />
(mm)<br />
Maximum<br />
External<br />
Depth<br />
(mm) 1<br />
Nominal<br />
Weight<br />
(kg)<br />
Security<br />
Grade<br />
Cert.<br />
No.<br />
H21 735 - 570 - 665 - 567 VI 954b/04<br />
H26 850 - 600 - 690 - 667 VI<br />
H24 790 - 690 - 730 - 720 VI<br />
H35 1090 - 690 - 730 - 924 VI<br />
H47 1390 - 690 - 830 - 1219 VI<br />
H55 1590 - 690 - 830 - 1359 VI<br />
H67 1890 - 940 - 830 - 1898 VI<br />
Z14 455 555 455 555 465 565 81 2 0 954b/05<br />
Z14S 455 555 405 505 370 470 68 2 0<br />
Z19 585 685 405 505 465 565 90 2 0<br />
Z19D 485 785 420 620 515 715 121 2 0<br />
Z23 485 885 420 620 515 715 135 2 0<br />
Z28 600 1000 450 650 540 740 159 2 0<br />
Z28W 600 1000 510 710 615 815 181 2 0<br />
Z35 800 1200 510 710 615 815 214 2 0<br />
Z35W 800 1200 700 900 615 815 257 2 0<br />
Z43 1000 1400 510 710 615 815 245 2 0<br />
Z43W 1000 1400 700 900 615 815 293 2 0<br />
Z51 1200 1600 510 710 615 815 278 2 0<br />
Z51W 1200 1600 700 950 615 815 331 2 0<br />
Z59 1400 1600 420 520 420 620 242 2 0<br />
Z59W 1400 1600 460 610 420 520 263 2 0<br />
A14 455 555 455 555 465 565 122 2 I 954b/06<br />
A14S 455 555 405 505 370 470 100 2 I<br />
A19 585 685 405 505 465 565 136 2 I<br />
A19D 485 785 420 620 515 715 201 2 I<br />
A23 485 885 420 620 515 715 211 2 I<br />
A28 600 1000 450 650 540 740 252 2 I<br />
A28W 600 1000 510 710 615 815 288 2 I<br />
A35 800 1200 510 710 615 815 342 2 I<br />
A35W 800 1200 700 900 615 815 414 2 I<br />
A43 1000 1400 510 710 615 815 395 2 I<br />
A43W 1000 1400 700 900 615 815 476 2 I<br />
A51 1200 1600 510 710 615 815 449 2 I<br />
A51W 1200 1600 700 950 615 815 539 2 I<br />
A59 1400 1600 420 520 420 620 384 2 I<br />
A59W 1400 1600 460 610 420 520 424 2 I<br />
Compatible Locks<br />
Manufacturer Model Type Euro Cash Safes (LPCB Ref. No. 954b/..)<br />
1 2 3 4 5 6<br />
Carl Wittkopp GmbH 1824-159-0 Mechanical key <br />
Carl Wittkopp GmbH / Tw in Lock 7220 Electronic<br />
<br />
Insys Microelectronics<br />
combination<br />
Kaba AG.<br />
SL523 and SL525 Electronic <br />
combination<br />
Kaba Ilco Corp. 673000 Mechanical<br />
<br />
combination<br />
Kaba Ilco Corp. A673000 Mechanical<br />
<br />
combination<br />
Kaba Mauer GmbH President 71111 Mechanical key <br />
20 Nov 2011 255
PART 4: SECTION 2.1<br />
SAFES<br />
Kaba Mauer GmbH Variator B - 70076 Mechanical key <br />
Kaba Mauer GmbH Praetor B - 70079 Mechanical key <br />
Kaba Mauer GmbH Variator A 70091 Mechanical key <br />
Kaba Mauer GmbH Variator A 70092 Mechanical key <br />
Kaba Mas Corp Auditcon 2 Electronic <br />
combination<br />
Kaba Mas Corp Auditcon 2100D Electronic <br />
combination<br />
Kaba Mas Corp Auditcon 3100 Electronic <br />
combination<br />
Kaba Mas Corp Cencon Electronic <br />
combination<br />
La Gard 1947 Mechanical<br />
<br />
combination<br />
La Gard 1985 Mechanical <br />
combination<br />
La Gard 3330-1 Mechanical<br />
<br />
combination<br />
La Gard 3332 Mechanical <br />
combination<br />
La Gard Combogard 3740 Electronic<br />
<br />
(Combo Basic) combination<br />
La Gard Combogard 6040 Electronic<br />
<br />
(39E)<br />
combination<br />
La Gard<br />
Combogard 66E Electronic<br />
<br />
w ith deadbolt combination<br />
Low e and Fletcher Ltd 3007 Mechanical key <br />
Low e and Fletcher Ltd 3012 Mechanical key <br />
Alternative Trade Names<br />
The Euro Cash safes are also marketed under the following alternative trade names<br />
Trade Name<br />
Alternative Trade Names<br />
Euro Cash Grade 0 Euro Cash Z-Series Euro Trader Grade 0 Euro Trader Z-Series<br />
Euro Cash Grade 1 Euro Cash A-Series Euro Trader Grade 1 Euro Trader A-Series<br />
Euro Cash Grade 3 Euro Cash T-Series Euro Trader Grade 3 Euro Trader T-Series<br />
Euro Cash Grade 4 Euro Cash F-Series Euro Trader Grade 4 Euro Trader F-Series<br />
Euro Cash Grade 5 Euro Cash P-Series Euro Trader Grade 5 Euro Trader P-Series<br />
Euro Cash Grade 6 Euro Cash H-Series Euro Trader Grade 6 Euro Trader H-Series<br />
Notes:<br />
1. If no maximum dimension is noted, the model is only approved in a single size; i.e. that listed in the minimum dimension column.<br />
2. The nominal weights noted vary by +/- 5% depending on the size of safe manufactured within the range of dimensions noted for that<br />
model.<br />
Certificate No: 954c to LPS 1183: Issue 4.2<br />
Free-standing Safe<br />
Product<br />
Name<br />
Size<br />
Ref.<br />
Minimum<br />
External<br />
Height<br />
(mm)<br />
Euro<br />
Cash<br />
Grade 5<br />
Maximum<br />
External<br />
Height<br />
(mm)<br />
Minimum<br />
External<br />
Width<br />
(mm)<br />
Maximum<br />
External<br />
Width (mm)<br />
Minimum<br />
External<br />
Depth<br />
(mm)<br />
Maximum<br />
External<br />
Depth (mm)<br />
Security<br />
Grade<br />
P62 1703 1706 688 691 748 751 V 954c/01<br />
Cert.<br />
No.<br />
256 20 Nov 2011
PART 4: SECTION 2.1<br />
SAFES<br />
Compatible Locks<br />
Manufacturer Model Type<br />
Kaba AG. Models SL523 and SL525 Electronic combination<br />
Kaba Mas Corp Auditcon 2100D Electronic combination<br />
Kaba Mas Corp Auditcon 3100 Electronic combination<br />
Kaba Mas Corp Auditcon 2 Electronic combination<br />
Kaba Mas Corp Cencon Electronic combination<br />
Kaba Mauer GmbH Variator B - 70076 Mechanical key<br />
Kaba Mauer GmbH Praetor B - 70079 Mechanical key<br />
La Gard 1985 Mechanical combination<br />
La Gard 3332 Mechanical combination<br />
Notes:<br />
1. The size P62 Euro Cash Grade 5 safe is a double door free-standing safe with integral depository.<br />
2. The security grade applies to the safe when both doors are closed, fully locked and the keys removed.<br />
3. The resistance of the horizontal divider and the deposit mechanism incorporated within that divider to manual forced entry attacks is<br />
outside the scope of this approval, as is the resistance to fishing and trapping provided by the deposit facility located within that<br />
divider.<br />
Lion Steelworks SDN. BHD.<br />
Lot 4, Solok Waja 3, Kawasan Perindustrian Bukit Raja, 41050 Klang, Selangor, Malaysia<br />
Tel: +603 3341 3822 • Fax: +603 3342 7630<br />
E-mail: lion@fmm.jaring.my<br />
Certificate No: 639a to LPS 1183: Issue 4<br />
Free-standing Safes<br />
Product Name<br />
Size<br />
Security<br />
Cert. No.<br />
Reference<br />
Grade<br />
N-Series N1, N2 and N3 III 639a/01<br />
Compatible Locks<br />
Manufacturer<br />
S&G6731<br />
S&G6880<br />
Model<br />
Mechanical Combination<br />
Mechanical Key<br />
Note:<br />
1. LPS 1183: Issue 4 is equivalent to BS EN 1143-1:1997 with the exception of the requirement for the locks to meet ENV 1300.<br />
SMP Security Limited<br />
Halesfield 24, Telford, Shropshire TF7 4NZ, United Kingdom<br />
Tel: +44 (0)1952 585673 • Fax: +44 (0)1952 582816<br />
E-mail: sales@smpsecurity.co.uk • Website: www.smpsecurity.co.uk<br />
Certificate No: 115a to LPS 1183: Issue 3<br />
Free-standing Safes<br />
Product Name Size References 1, 2 Security<br />
Fire Resistance to<br />
Cert. No.<br />
Grade<br />
BS 476: Part 20: 1987<br />
Community 1414 (39) ED (58)<br />
1814 (50) ED (74)<br />
2316 (103) ED (138)<br />
2916 (130) ED (174)<br />
3520 (230) ED (297)<br />
5020 (328) ED (424)<br />
6020 (393) ED (509)<br />
Mini-Vault (702) ED (910)<br />
I 60 115a/01<br />
20 Nov 2011 257
PART 4: SECTION 2.1<br />
SAFES<br />
Product Name Size References 1, 2 Security<br />
Fire Resistance to<br />
Cert. No.<br />
Grade<br />
BS 476: Part 20: 1987<br />
1814 (50) ED (74)<br />
II 60 115a/02<br />
2316 (103) ED (138)<br />
2916 (130) ED (174)<br />
3520 (230) ED (297)<br />
5020 (328) ED (424)<br />
6020 (393) ED (509)<br />
Mini-vault (702) ED (910)<br />
1814 (50) ED (74)<br />
III 60 115a/03<br />
2316 (103) ED (138)<br />
2916 (130) ED (174)<br />
3520 (230) ED (297)<br />
5020 (328) ED (424)<br />
6020 (393) ED (509)<br />
Mini-vault (702) ED (910)<br />
60 50 40 (120) ED (165)<br />
90 50 40 (180) ED (247)<br />
90 40 47.5 (171)<br />
92 42 48.5 (187.4)<br />
120 50 40 (240) ED (330)<br />
120 40 47.5 (228)<br />
122 42 48.5 (248.5)<br />
150 50 40 (300) ED (412)<br />
IV - 115a/04<br />
Compatible Locks<br />
Lock Type Com munity Safe (LPCB Ref. No. 115a/…)<br />
1 2 3 4<br />
Carl Wittkopp GmbH 1819 Mechanical key <br />
Carl Wittkopp GmbH 1821 Mechanical key <br />
Kaba Mas Corporation SL 523 Electronic combination <br />
Kaba Mas Corporation SL 525 Electronic combination <br />
KG Group EM25-20 Electronic combination <br />
KG Group EM35-20 Electronic combination <br />
KG Group ML67-40 Mechanical combination <br />
La Gard 1947 Mechanical combination <br />
La Gard 1985 Mechanical combination <br />
La Gard 3330 Mechanical combination <br />
La Gard Combogard 33E Electronic combination <br />
La Gard Combogard 3740 (Combo Basic) Electronic combination <br />
La Gard Combogard 6040 (39E) Electronic combination <br />
La Gard Combogard 66E w ith deadbolt Electronic combination <br />
La Gard Safeguard 3000/2441 Electronic combination <br />
La Gard Safeguard 3035/2441 Electronic combination <br />
Low e and Fletcher 3007 Mechanical key <br />
Low e and Fletcher 3010 Mechanical key <br />
Low e and Fletcher 3011 Mechanical key <br />
Low e and Fletcher 3012 Mechanical key <br />
Mauer 70076 Mechanical key <br />
Mauer 70077 Mechanical key <br />
Mauer 70079 Mechanical key <br />
Mauer 70091 Mechanical key <br />
Mauer 70092 Mechanical key <br />
Mauer 71111 Mechanical key <br />
S&G 6730 Mechanical combination <br />
S&G 6731 Mechanical combination <br />
SMP S520D7-C Mechanical key <br />
SMP S520D9-C Mechanical key <br />
Notes:<br />
1. ED denotes available with up to 150mm extra depth.<br />
2. Figures in brackets denote the volumes in litres. The first figure is the standard volume, the second figure is the volume of safe with<br />
maximum 150mm extra depth.<br />
258 20 Nov 2011
PART 4: SECTION 2.1<br />
SAFES<br />
Certificate No: 115b to LPS 1183: Issue 4<br />
Free-standing Safes<br />
Product Name Size References 1, 2 Security<br />
Fire Resistance to<br />
Cert. No.<br />
Grade<br />
BS 476:Part 20: 1987<br />
Community 1414 (39) ED (58)<br />
0 60 115b/10<br />
1814 (50) ED (74)<br />
2316 (103) ED (138)<br />
2916 (130) ED (174)<br />
3520 (230) ED (297)<br />
5020 (328) ED (424)<br />
1414 (39) ED (58)<br />
0 60 115b/11<br />
1814 (50) ED (74)<br />
2316 (103) ED (138)<br />
2916 (130) ED (174)<br />
3520 (230) ED (297)<br />
5020 (328) ED (424)<br />
60 50 40 (120) ED (165)<br />
90 50 40 (180) ED (247)<br />
120 50 40 (240) ED (330)<br />
150 50 40 (300) ED (412)<br />
V - 115b/05<br />
Compatible Locks<br />
Lock Type Com munity Safe<br />
(LPCB Ref. No. 115b/…)<br />
5 10 11<br />
Carl Wittkopp GmbH 1819 Mechanical key <br />
Carl Wittkopp GmbH 1821 Mechanical key <br />
Kaba Mas Corporation SL 523 Electronic combination <br />
Kaba Mas Corporation SL 525 Electronic combination <br />
KG Group EM25-20 Electronic combination <br />
KG Group EM35-20 Electronic combination <br />
KG Group ML67-40 Mechanical combination <br />
La Gard 1947 Mechanical combination <br />
La Gard 1985 Mechanical combination <br />
La Gard 3330 Mechanical combination <br />
La Gard Combogard 33E Electronic combination <br />
La Gard Combogard 3740 (Combo Basic) Electronic combination <br />
La Gard Combogard 6040 (39E) Electronic combination <br />
La Gard Combogard 66E w ith deadbolt Electronic combination <br />
La Gard Safeguard 3000/2441 Electronic combination <br />
La Gard Safeguard 3035/2441 Electronic combination <br />
Low e and Fletcher 3007 Mechanical key <br />
Low e and Fletcher 3010 Mechanical key <br />
Low e and Fletcher 3011 Mechanical key <br />
Low e and Fletcher 3012 Mechanical key <br />
Mauer 70076 Mechanical key <br />
Mauer 70077 Mechanical key <br />
Mauer 70079 Mechanical key <br />
Mauer 70091 Mechanical key <br />
Mauer 70092 Mechanical key <br />
Mauer 71111 Mechanical key <br />
S&G 6730 Mechanical combination <br />
S&G 6731 Mechanical combination <br />
SMP S520D7-C Mechanical key <br />
SMP S520D9-C Mechanical key <br />
Notes:<br />
1. ED denote available wit up to 150mm extra depth.<br />
2. Figures in brackets denote the volumes inlitres. The first figure is the standard volume, the second figure is the volume of safe with<br />
maximum 150mm extra depth.<br />
3. LPS 1183: Part 1: Issue 4 is equivalent to BS EN1143-1: 1997, with the exception of the requirements for locks to meet ENV1300.<br />
20 Nov 2011 259
PART 4: SECTION <strong>2.2</strong><br />
SECURE SAFE CABINETS<br />
The Secure safe cabinets listed in this <strong>section</strong> are approved by LPCB to EN 14450 Secure storage units -<br />
Requirements, classification and methods of test for resistance to burglary - Secure safe cabinets.<br />
Dudley Safes Limited<br />
Unit 17 Deepdale Works, Deepdale Lane, Upper Gornal, Dudley, West Midlands DY3 2AF, United Kingdom<br />
Tel: +44 (0)1384 239991 • Fax: +44 (0)1384 455129<br />
Website: www.dudleysafes.com<br />
Certificate No: 304b to BS EN 14450: 2005<br />
Secure Safe Cabinets<br />
Product Name Size Reference Security<br />
Cert. No.<br />
Level<br />
Harlech Lite (Level 1) 00, 0, 1, 2, 3, 4, 5 and 6 S1 304b/01<br />
Harlech Lite (Level 2) 00, 0, 1, 2, 3, 4, 5 and 6 S2 304b/02<br />
Compatible Locks<br />
Model Type Security Cabinet<br />
(LPCB Ref. No. 304b/..)<br />
01 02<br />
Auditcon 52 Electronic Combination <br />
Caw i 2648 Mechanical Key <br />
Kaba 252 Electronic Combination <br />
Kaba 525 Electronic Combination <br />
Kaba MAS 552 Electronic Combination <br />
LaGard 1985 Mechanical Combination <br />
LaGard 3330 Electronic Combination <br />
LaGard 3740 Electronic Combination <br />
LaGard Combogard 33E Electronic Combination <br />
LaGard Combogard 39E Electronic Combination <br />
LaGard Combogard 66E Electronic Combination <br />
M-Locks EM3520 Electronic Combination <br />
M-Locks EM3550 Electronic Combination <br />
Mauer President A 71111 Mechanical Key <br />
Opus 060/EM25.20 Electronic Combination <br />
S&G 6730 Mechanical Combination <br />
S&G 6731 Mechanical Combination <br />
Godrej & Boyce Mfg. Co. Ltd. (Security Equipment Division)<br />
Plant - 17, Pirojshanagar, Vikhroli, Mumbai 400 079, India<br />
Tel: +91 22 679 64771 • Fax: +91 22 679 61509<br />
E-mail: securityexports@godrej.com or secure@godrej.com • Website: www.godrej.com<br />
Certificate No: 954a to BS EN 14450: 2005<br />
Secure Safe Cabinets<br />
Product Name Model External External External Weight (kg) Security Level Cert. No.<br />
Width (mm) Height (mm) Depth (mm)<br />
Euro-Lite FS10 325 275 325 26 S2 954a/01<br />
260 20 Nov 2011
PART 4: SECTION <strong>2.2</strong><br />
SECURE SAFE CABINETS<br />
Product Name Model External External External Weight (kg) Security Level Cert. No.<br />
Width (mm) Height (mm) Depth (mm)<br />
FS40 450 330 380 40 S2<br />
FS50 360 430 400 41 S2<br />
FS45 490 470 410 56 S2<br />
FS65 490 660 410 73 S2<br />
FS85 490 860 410 91 S2<br />
Compatible Locks<br />
Manufacturer Model Type<br />
Carl Wittkopp GmbH 2648 Mechanical key lock<br />
Carl Wittkopp GmbH CombiStar 7250 Electronic combination<br />
Kaba Mas Corporation Auditcon 2 Electronic combination<br />
Kaba Mas Corporation Auditcon 3100 Electronic combination<br />
Kaba Mas Corporation SL 525 Electronic combination<br />
Kaba Mauer GmbH President 71111 Mechanical key lock<br />
Kaba Mauer GmbH Variator A 70091 Mechanical key<br />
Kaba Mauer GmbH Variator A 70092 Mechanical key<br />
KG Group EM25.20 Electronic combination<br />
KG Group EM30.20 Electronic combination<br />
KG Group EM35.20 Electronic combination<br />
La Gard 3330-1 Mechanical combination<br />
La Gard Combogard 3740 (Combo Basic) Electronic combination<br />
La Gard Combogard 6040 (39E) Electronic combination<br />
La Gard Combogard 66E w ith deadbolt Electronic combination<br />
Steinbach & Vollmann GmbH & Co. Series 4.19.92 Mechanical key lock<br />
Alternative Brands and Models<br />
Type Product<br />
Name<br />
Model<br />
Primary Euro-Lite FS10 FS40 FS50 FS45 FS65 FS85<br />
Alternative<br />
Guardian S2 FS10 FS40 FS50 FS45 FS65 FS85<br />
EVVA TR1000 TR4000 TR5000 TR4500 TR6500 TR8500<br />
do it TR1000 TR4000 TR5000 TR4500 TR6500 TR8500<br />
SMP Security Limited<br />
Halesfield 24, Telford, Shropshire TF7 4NZ, United Kingdom<br />
Tel: +44 (0)1952 585673 • Fax: +44 (0)1952 582816<br />
E-mail: sales@smpsecurity.co.uk • Website: www.smpsecurity.co.uk<br />
Certificate No: 115c to BS EN 14450: 2005<br />
Secure Safe Cabinet<br />
Product Name Model External External External Approx. Security Cert. No.<br />
Width (mm) Height (mm) Depth (mm) Weight (kg) Level<br />
Concept 2 1 436 382 382 34 S2 115c/01<br />
2 536 430 382 43 S2<br />
3 491 489 482 50 S2<br />
4 666 489 482 63 S2<br />
5 816 489 482 75 S2<br />
6 1010 608 682 125 S2<br />
7 1372 608 682 162 S2<br />
Concept 3 1 434 382 394 50 S2 115c/02<br />
2 534 430 394 62 S2<br />
3 489 489 494 74 S2<br />
4 664 489 494 92 S2<br />
5 814 489 494 110 S2<br />
20 Nov 2011 261
PART 4: SECTION <strong>2.2</strong><br />
SECURE SAFE CABINETS<br />
Product Name Model External<br />
Width (mm)<br />
External<br />
Height (mm)<br />
External<br />
Depth (mm)<br />
Approx.<br />
Weight (kg)<br />
Security<br />
Level<br />
6 1008 608 694 171 S2<br />
7 1370 608 694 221 S2<br />
Cert. No.<br />
Compatible Locks<br />
Manufacturer Model Type Product<br />
Concept 2 Concept 3<br />
KG Group EM25-20 Electronic combination <br />
KG Group EM35-20 Electronic combination <br />
KG Group ML67-40 Mechanical combination <br />
LaGard 3330 Mechanical combination <br />
LaGard Combogard 33E1 Electronic combination <br />
LaGard Combogard Basic 3740 Electronic combination <br />
LaGard Basic Auditgard 66E Electronic combination <br />
LaGard Combogard Pro 39E Electronic combination <br />
Low e and Fletcher 3007 Mechanical key <br />
Low e and Fletcher 3012 Mechanical key <br />
Mauer 70091 Mechanical key <br />
Mauer 71111 Mechanical key <br />
S&G 6730 Mechanical combination <br />
Note:<br />
1. No evidence was available to confirm these locks met the minimum lock requirements specified in Table 1 of BS EN 14450: 2005 at<br />
the time of issuing approval. None the less, the cabinets met all other requirements of BS EN 14450: 2005 and all requirements of<br />
prEN 14450: June 2004 when fitted with these locks.<br />
262 20 Nov 2011
PART 4: SECTION 2.3<br />
AUTOMATIC TELLER MACHINE (ATM) SAFES<br />
Figures released by the British Bankers’ Association in March 2006 showed that there were 879 physical<br />
attacks on ATMs in 2005. That is an average of 73 per month. In that year alone, the ATM sector suffered<br />
pure cash losses of £8,574,210 - equating to an average of £23,000 per day.<br />
This represented a sharp rise in losses through ATM crime compared with previous years. Since then theft of<br />
ATM safes or money from ATM safes has not abated reinforcing the need for ATM estate mangers to ensure<br />
their ATM safes meet appropriate security standards.<br />
By selecting ATMs that incorporate a safe graded to LPS 1183 or EN 1143-1, ATM losses can be significantly<br />
reduced due to the increased time and effort required to overcome the mounting system and gain entry to the<br />
contents of the safe itself.<br />
As with free-standing safes and strongrooms, the locks fitted to the ATM safe and construction of the safe are<br />
critical. Specifiers and users should therefore discuss any proposals with their insurance company and the<br />
safe manufacturer prior to undertaking such work.<br />
Please note that the fixing system employed forms <strong>part</strong> of the over all classification assessment. As such, the<br />
use of alternative fixings or anchor systems, while generally well intentioned, may undermine the security<br />
afforded by the ATM safe and invalidate the approval. It is also important to check locking mechanisms<br />
regularly to ensure they have not been tampered with.<br />
The same rigorous approval procedures and conditions are applied to the ATM safes listed in this <strong>section</strong> as<br />
are applied to free standing safes, strongrooms and deposit safes.<br />
20 Nov 2011 263
PART 4: SECTION 2.4<br />
ANTI-BANDIT ATM SECURITY DEVICES<br />
A number of ATMs have been attacked while being replenished as this is when there is the most cash held<br />
within the ATM and the cash cassettes are the most vulnerable because the door to the ATM safe is open.<br />
Products listed in this <strong>section</strong> are designed to prevent the unauthorised removal of cash cassettes from the<br />
ATM safe when the ATM safe door is open.<br />
These products have been approved to LPS 1175 Requirements and testing procedures for the LPCB<br />
approval and listing of intruder resistant building components, strongpoints, security enclosures and free<br />
standing barriers.<br />
LPS 1175 is based on manual attack testing and currently defines eight levels of resistance to entry.<br />
These are measured in terms of attack tools and time available to the attacker. This enables specifiers to<br />
select products according to the risks that they and their property face.<br />
Due to the intended application of these products, the entry criteria used to assess these products in<br />
accordance with clause 4.3 of LPS 1175 is defined in the notes relating to each of the products listed.<br />
Although the evaluation and approval covers attempts to remove the products from the ATM safes to which<br />
they are fitted, they do not cover the attack resistance of those ATM safes.<br />
Pressex UK Limited<br />
Kingsway South, Team Valley, Gateshead, Tyne & Wear NE11 0SH, United Kingdom<br />
Tel: +44 (0)191 497 3430 • Fax: +44 (0)191 497 3431<br />
E-mail: pressex@responsive-engineering.com • Website: www.responsive-engineering.com<br />
Certificate No: 870a to LPS 1175: Issue 6<br />
Anti-Bandit ATM Security Device<br />
Product Name Compatible ATMs Security Cert. No.<br />
Rating<br />
Lockpoint ATM Duress Guard NCR 84 ATM incorporating an NCR 5884<br />
UL291 ATM safe<br />
NCR 87 ATM incorporating an NCR 5887<br />
UL291 ATM safe<br />
3 870a<br />
Notes:<br />
1. The Lockpoint ATM Duress Guard permits access to individual cash cassettes within the ATMs listed above once the door to the ATM<br />
safe has been opened. This is possible without the need for the operator to remember an access code or use a coded key, token or<br />
other such device to operate the doors on the Lockpoint ATM Duress Guard.<br />
2. The Lockpoint ATM Duress Guard prevents removal of individual cash cassettes from within the ATMs via the aperture created when<br />
the door to the ATM safe is opened. The level of protection against unauthorised removal of the replenished cash cassettes is<br />
expressed in the above table as a Security Rating in accordance with the requirements of LPS1175: Issue 6. The Security Rating is<br />
achieved by the Lockpoint ATM Duress Guard for up to 60 minutes after the door(s) to the com<strong>part</strong>ments in which the replenished<br />
cassettes are located. This is providing the doors to the adjacent com<strong>part</strong>ments have also been operated to activate the locking<br />
system on those doors. The Lockpoint ATM Duress Guard provides protection to individual replenished cash cassettes while those in<br />
adjacent com<strong>part</strong>ments are being replenished at least compatible with the requirements of Security Rating 1.<br />
3. The product’s resistance to electronic and digital attack methods, other than those possible with tools defined in LPS 1175: Issue 6 1<br />
for the Security Ratings achieved, are outside the scope of this approval.<br />
4. This approval does not cover the attack resistance of the ATM into which the Lockpoint ATM Duress Guard is fitted. However, the<br />
approval does cover the resistance to unauthorised removal of the Lockpoint ATM Duress Guard from the ATM via the aperture<br />
created when the door to the ATM safe is opened.<br />
264 20 Nov 2011
PART 4: SECTION 2.5<br />
DEPOSIT SAFES<br />
Safes that incorporate a deposit facility are covered by EN 1143-2 Requirements, classification and methods<br />
of test for resistance to burglary - Part 2: Deposit systems. This describes tests over and above those<br />
specified in EN 1143-1, and includes ‘forcing’, ‘fishing’, ‘trapping’ and ‘deposit retrieval’.<br />
Deposit safes take a number of forms and these affect the classification attributed to them.<br />
Deposit safes are normally located within a building and are primarily designed to enable employees to<br />
deposit money or other items without having to open the main door of the safe. Deposit safes receive a<br />
classification of “D-#” where # is the grade of resistance achieved during testing.<br />
Deposit safes range from standard deposit safes with manual operation through to the distributed deposit<br />
systems employed by supermarkets.<br />
Night safes, on the other hand, are often accessible from the street and are primarily used by financial<br />
institutions for providing a secure depositing system for their customers. Night safes receive a classification of<br />
“N-#” where # is the grade of resistance achieved during testing.<br />
20 Nov 2011 265
PART 4: SECTION 2.6<br />
STRONGROOMS<br />
Strongrooms listed in this <strong>section</strong> are approved by LPCB to one or more of the following standards:<br />
<br />
<br />
EN 1143-1 Secure storage units. Requirements, classification and methods of test for resistance to<br />
burglary. Safes, strongroom doors and strongrooms.<br />
LPS 1183 Specification for safe storage units. Part 1: Safes and strongrooms<br />
Copies of LPS 1183 can be downloaded free of charge from our website www.<strong>RedBookLive</strong>.com.<br />
Strongrooms take two forms:<br />
<br />
<br />
Cast in-situ. The strongroom structure is cast on site where there is insufficient access to manoeuvre<br />
prefabricated panels into place.<br />
Pre-fabricated. The strongroom is formed on site from pre-fabricated panels, designed to bolt together<br />
securely to form the desired configuration.<br />
Strongrooms are not only designed to secure larger volumes of cash and jewellery but are increasingly used<br />
to store items such as artwork and antiquities, pharmaceuticals, military equipment and highly sensitive<br />
documentation. Strongrooms are also increasingly being used to protect large scale IT server hubs due to the<br />
high value of the server equipment and business continuity risks associated with the potential loss of such<br />
equipment or data.<br />
It is important to ensure that all exposed fixings, jointing plates, the substrate into which the device is fitted<br />
and the locking mechanisms are regularly checked to ensure that they are in good condition and that they<br />
have not been tampered with.<br />
It is also important to ensure only those design options listed, such as special cable access or ventilation<br />
panels, are incorporated within the strongroom construction as the use of alternative options may undermine<br />
the level of security provided by the strongroom.<br />
Explosion (EX) Designation<br />
This designation indicates a product offers resistance to detonation of a PETN (Pentaerythritol tetranitrate)<br />
explosive charge followed by post detonation tool attacks aimed at achieving entry to the strongroom. Where<br />
the use of explosive charges is perceived to be a threat it is recommended products with this designation are<br />
selected.<br />
Core Drill (CD) Designation<br />
This designation is only applicable to strongrooms and strongroom doors achieving grades V and above. This<br />
designation reflects the ability of a product to pass the diamond drill test specified within EN 1143-1 which is<br />
designed to demonstrate the product’s superior resistance to methods of forced entry that solely involve the<br />
use of diamond core drills.<br />
266 20 Nov 2011
PART 4: SECTION 3<br />
SECURE OFFICE FURNITURE<br />
Office furniture and other equipment designed to prevent unauthorised access to confidential and valuable<br />
documents are tested and certified to LPS 1228 Specification for testing and classifying the burglary<br />
resistance of office furniture. The standard was developed for the Cabinet Office as a means of specifying and<br />
testing the resistance offered by office furniture and document cabinets to unauthorised access.<br />
The standard specifies four levels of protection based on the availability of tools and time to the attacker. This<br />
enables specifiers to select the equipment that best suits their needs, such as a filing cabinet, cupboard or<br />
document safe, whilst knowing that the equipment will provide the required level of protection against<br />
unauthorised access, whether in a domestic, commercial or Government environment.<br />
The burglary resistance of the complete product is tested, including any in-situ hardware such as locks and<br />
hinges. However, no allowance is made for various stages of locking. The locks assessed as <strong>part</strong> of the<br />
evaluation of the product are listed under the ‘compatible locks’ <strong>section</strong> of each company’s entry.<br />
It is important that specifiers only select products covered by the scope detailed on the certificate as the<br />
performance of products that fall outside the scope of the assessment may not be adequate. It is also<br />
important to ensure that the products are installed in accordance with the manufacturer’s instructions and that<br />
all exposed fixings, the substrate into which the device is fitted and the locking mechanisms are regularly<br />
checked to ensure that they are in good condition and that they have not been tampered with. This will ensure<br />
that criminals cannot simply remove the security device to a remote location in order to gain access to the<br />
protected documentation or equipment.<br />
20 Nov 2011 267
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Security enclosures that have been assessed to LPS 1175 Specification for testing and Classifying the<br />
Burglary Resistance of Building Components, Strongpoints and Security Enclosures are listed in this <strong>section</strong>.<br />
Each security rating is appropriate to the level of risk to forced entry or removal, and covers everything from<br />
the secure storage of tools in the domestic environment, to protection of remote equipment on railway and<br />
telecommunications infrastructures. Some examples of applications include: secure site tool and plant storage<br />
units, portable office buildings and shipping containers.<br />
The use of appropriately rated and installed physical security enclosures will protect the contents of the<br />
enclosure from the unwanted attentions of the opportunist or professional criminal.<br />
LPS 1175 is based on manual attack testing and currently defines eight levels of resistance to entry into the<br />
enclosure or removal of the enclosure from the supporting substrate. The ratings are determined in terms of<br />
attack tools and time available to the attacker, and enables specifiers to select products according to the risks<br />
that they and their property face. Unless otherwise stated, entry into the enclosures listed was determined<br />
according to the ability to pass the 400 mm by 225 mm elliptical test block defined in LPS 1175. This is<br />
considered to be a size through which a person may pass. In some cases alternative failure criteria was used<br />
during the evaluation of the enclosures listed. These were designed to suit the intended application of the<br />
enclosures concerned and the failure criteria used is noted in the relevant product entries.<br />
It is important to ensure that the enclosures are installed in accordance with the manufacturers instructions<br />
and that all exposed fixings, the substrate onto which the enclosure is fitted, and the locking mechanisms are<br />
regularly checked to ensure that they are in good condition and that they have not been tampered with.<br />
Details regarding the rating system can be found in the standard itself, copies of which are available free of<br />
charge and can be downloaded from the LPCB web site www.<strong>RedBookLive</strong>.com.<br />
It is recommended that assets such as cash or jewellery should preferably be stored in safe storage units or<br />
strongrooms approved by LPCB. These are listed in Section 2. Those looking to prevent unauthorised<br />
removal of computer equipment consider using the physical protection devices listed in Section 12.<br />
Asgard Secure Steel Storage (a trading division of Flexiform Business Furniture<br />
Limited)<br />
1392 Leeds Road, Bradford BD3 7AE, United Kingdom<br />
Tel: +44 (0)1274 706206 • Fax: +44 (0)1274 706247<br />
Certificate No: 596a to LPS 1175: Issue 5<br />
Security Enclosures<br />
Product Name<br />
Nominal Enclosure Nominal Enclosure Nominal Enclosure Security Cert. No.<br />
Height (m)<br />
Width (m)<br />
Depth (m) Rating<br />
Asgard Classic Secure Unit 1.9 1.9 0.8 1 596a/01<br />
Asgard Compact Secure Unit 1.9 1.1 0.8 1 596a/02<br />
Asgard Universal 0.7 0.6 0.5 1 596a/03<br />
Asgard Annexe 1.5 1.8 0.9 1 596a/04<br />
Compatible Locks<br />
Lock Type LPCB Ref. No 596a/..<br />
Winlock<br />
HS2000<br />
Accessories<br />
Garage door locking system fitted w ith Euro Profile<br />
1850/05/30 single cylinder<br />
1 2 3 4<br />
<br />
268 20 Nov 2011
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Accessory<br />
Tool Rail <br />
Adjustable Shelf<br />
LPCB Ref. No 596a/..<br />
1 2 3 4<br />
<br />
Notes:<br />
1. In order to prevent complete removal of the secure units, they must be affixed to concrete foundations in accordance with the self<br />
assembly instructions supplied with the units.<br />
2. On products with sloping or peaked roof design, the height given is the maximum.<br />
Bastion Security Installations Limited<br />
Finlay Court, Simonside East Industrial Estate, South Shields, Tyne and Wear NE34 9QA, United Kingdom<br />
Tel: +44 (0)191 419 3777 • Fax: +44 (0)191 497 2997<br />
E-mail: moreinfoplease@bastionprotects.com • Website: www.bastionprotects.com<br />
Certificate No: 1046a to LPS 1175: Issue 7<br />
Expandable Security Enclosure<br />
Product<br />
Name<br />
Type<br />
Height<br />
(m)<br />
Bastion<br />
Enclosure<br />
Expanding security<br />
enclosure 1 with integral<br />
entrance doorset<br />
Width<br />
(m)<br />
Length When<br />
Enclosure Is Fully<br />
Expanded (m)<br />
Length When<br />
Enclosure Is<br />
Contracted (m)<br />
Security<br />
Rating<br />
Cert. No.<br />
2.469 1.700 2.655 1.700 5 2 1046a/01<br />
3<br />
Manufacturer Model Type Operating Devices Compatible<br />
Compatible Doorset Locking System<br />
Internal Face External Face<br />
Cylinders<br />
Tindall Engineering<br />
Limited<br />
Mico Evo AD3 w ith<br />
USCH 5<br />
Three point lock w ith integrated<br />
automatic deadlock and USCH 5<br />
cylinder guard<br />
Key and lever<br />
handle<br />
Key and lever<br />
handle<br />
A<br />
4<br />
Manufacturer Model Type Operating Devices Compatible<br />
Compatible Corridor Locking System<br />
Internal Face External Face<br />
Cylinders<br />
ASSA 766 Roller Bolt Tw o deadlocks 5 None Key A<br />
Compatible Cylinders<br />
Ref. Manufacturer Model Type<br />
A Access2 Tigris Omega Scandinavian Oval<br />
Notes:<br />
1. The enclosure may be used to house ATM’s. The resistance of ATM’s used within the enclosure is outside the scope of approval. It is<br />
the manufacturers’, and other clients’, responsibility to ensure the ATM and the aperture within which it is located cannot be exploited<br />
in order to gain entry into the enclosure.<br />
2. The enclosure achieves a Security Rating 5 classification in the optimum locked condition, i.e. when placed in the contracted (i.e.<br />
unexpanded) position, the staples are secured with the two locks listed in the ‘compatible corridor locking systems’ table and the lock<br />
on the doorset is secured. A Security Rating 3 classification prevails in the minimum locked condition, i.e. the enclosure is expanded<br />
and the lock on the doorset is secured.<br />
3. This lock secures the integral doorset.<br />
4. These locks secure the enclosure into the contracted (i.e. unexpanded) position.<br />
5. The external face of the cylinder is protected by a USCH 3 cylinder guard supplied by Tindall Engineering Limited.<br />
6. The approval covers the enclosures when installed onto concrete bases of equivalent resistance to attack, using the method of<br />
installation defined on the ‘Installation Instructions’ drawing (Revision A, dated 3 August 2011).<br />
20 Nov 2011 269
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Isoclad Limited<br />
10 Alder Road, West Chirton North Industrial Estate, North Shields, Tyne & Wear NE29 8SD, United Kingdom<br />
Tel: +44 (0)191 258 5052 • Fax: +44 (0)191 259 5742<br />
E-mail: sales@isoclad.co.uk • Website: www.isoclad.co.uk<br />
Certificate No: 142c to LPS 1175: Issue 6<br />
Modular Security Enclosure System<br />
Product<br />
Name<br />
Product<br />
Type<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height (m)<br />
Securiclad Enclosure<br />
with<br />
horizontal<br />
laid panels<br />
Enclosure<br />
with<br />
vertically<br />
laid panels<br />
Enclosure<br />
with<br />
horizontal<br />
laid panels<br />
Enclosure<br />
with<br />
vertically<br />
laid panels<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Minimum<br />
Depth (m)<br />
Maximum<br />
Depth (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
2.5 Unlimited 2.5 Unlimited 2.5 Unlimited 3 142c/01<br />
2.5 6.0 0.25 Unlimited 0.25 Unlimited 3<br />
2.5 Unlimited 2.5 Unlimited 2.5 Unlimited 4 142c/02<br />
2.5 6.0 0.25 Unlimited 0.25 Unlimited 4<br />
System Components<br />
Component Type<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Thickness<br />
(m)<br />
SR3/SR4 panel (mineral w ool) 0.25 1.19 2.5 6 0.1<br />
Ceiling panel (mineral w ool) 0.25 1.19 1 6 0.1<br />
SR3/SR4 panel (PIR) 0.25 1.19 2.5 6 0.1<br />
Ceiling panel (PIR) 0.25 1.19 1 6 0.1<br />
Products Compatible with the Securiclad Security Panel System 2,3<br />
270 20 Nov 2011
Manufacturer Product Name Product Type LPCB<br />
Certificate<br />
Number<br />
Ascot Doors Limited<br />
Benw eldSecure<br />
Pow ershield Doors<br />
Limited<br />
Selectaglaze Limited<br />
Professional Barriers<br />
Limited<br />
Ascot Doors Limited<br />
Pow ershield Doors<br />
Limited<br />
Centurion A363S Single leaf<br />
outw ard<br />
opening<br />
doorset<br />
Centurion A363D Double leaf<br />
outw ard<br />
opening<br />
doorset<br />
Bew dley doorset Single leaf<br />
outw ard<br />
opening<br />
doorset<br />
Pow ershield<br />
Class 3 single<br />
Pow ershield<br />
Class 3 double<br />
Series 55’ level<br />
3’<br />
Single leaf<br />
outw ard<br />
opening<br />
doorset<br />
Double leaf<br />
outw ard<br />
opening<br />
doorset<br />
Fixed light<br />
security<br />
w indow<br />
Security<br />
Rating<br />
131d/04 3 12, 13, 15,<br />
16, 18 and<br />
19<br />
131d/05 3 12, 13, 15,<br />
16, 18 and<br />
19<br />
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Compatible Locking<br />
Systems<br />
Active Leaf Passive<br />
Leaf<br />
N/A<br />
34, 35 and<br />
36<br />
746a/01 3 1 N/A<br />
852a/01 3 2 to 11,<br />
13,16,17 and<br />
19<br />
852a/02 3 2 to 11,<br />
13,16,17 and<br />
19<br />
N/A<br />
32<br />
683a/06 3 N/A N/A<br />
Extendor Eclipse Collapsible grille 869a/01 3 33 N/A<br />
Centurion A355 Single leaf<br />
outw ard<br />
opening<br />
doorset<br />
Centurion A364S Single leaf<br />
outw ard<br />
opening<br />
doorset<br />
Centurion A364D Double leaf<br />
outw ard<br />
opening<br />
doorset<br />
Pow ershield<br />
Class 4 single<br />
Single leaf<br />
outw ard<br />
opening<br />
doorset<br />
131d/01 4 13 N/A<br />
131d/02 4 13, 16, 19,<br />
27, 29 and<br />
31<br />
131d/03 4 13, 16, 19,<br />
27, 29 and<br />
31<br />
852a/03 4 3, 5, 7, 9, 10,<br />
13, 16, 19,<br />
20, 21, 22,<br />
23, 24, 26,<br />
28 and 30<br />
N/A<br />
34, 35 and<br />
36<br />
N/A<br />
Pow ershield<br />
Class 4 double<br />
Double leaf<br />
outw ard<br />
opening<br />
doorset<br />
852a/04 4 3, 5, 7, 9, 10,<br />
13, 16, 19,<br />
20, 21, 22,<br />
23, 24, 26,<br />
28 and 30<br />
32<br />
Compatible Locking Systems for Products Compatible with the Securiclad Security Panel System<br />
20 Nov 2011 271
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Com patible<br />
Locking<br />
Systems<br />
1 Assa 9787 Single point mortice<br />
hook lock<br />
2 MICO 942-3L<br />
EPC INT AD /<br />
HSCH 3<br />
3 MICO 942-3L<br />
EPC INT AD<br />
Model Type Operation<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
4 MICO 942-3 EPC 3-w ay locking system<br />
INT MD / HSCH 3 w ith manual deadlock<br />
5 MICO 942-3 EPC<br />
INT MD<br />
6 MICO 942-3P<br />
EPC INT MD /<br />
HSCH 3<br />
7 MICO 942-3P<br />
EPC INT MD<br />
8 MICO 942-3L<br />
EPC INT MD /<br />
HSCH 3<br />
9 MICO 942-3L<br />
EPC INT MD<br />
10 MICO 942-3L INT<br />
AD<br />
3-w ay locking system<br />
w ith manual deadlock<br />
3-w ay locking system<br />
w ith manual deadlock<br />
3-w ay locking system<br />
w ith manual deadlock<br />
3-w ay locking system<br />
w ith manual deadlock<br />
3-w ay locking system<br />
w ith manual deadlock<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
Key<br />
Entry<br />
Europrofile<br />
cylinder w ithin<br />
the HSCH 3<br />
cylinder guard<br />
and lever handle<br />
None<br />
Europrofile<br />
cylinder w ithin<br />
the HSCH 3<br />
cylinder guard<br />
and lever handle<br />
None<br />
Europrofile<br />
cylinder w ithin<br />
the HSCH 3<br />
cylinder guard<br />
and lever handle<br />
None<br />
Europrofile<br />
cylinder w ithin<br />
the HSCH 3<br />
cylinder guard<br />
and lever handle<br />
None<br />
None<br />
Exit<br />
Key via an Assa<br />
256 (Assa<br />
Classic)<br />
combined<br />
cylinder ring and<br />
thumbturn<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
lever handle<br />
Europrofile<br />
cylinder<br />
(key:key)and<br />
lever handle<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
panic exit push<br />
plate<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
panic exit push<br />
plate<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
push pad<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
push pad<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
lever handle<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
lever handle<br />
Scandinavian<br />
oval cylinder and<br />
lever handle<br />
Compatible<br />
Cylinders<br />
Q or R<br />
A, B, C, D, E<br />
or F<br />
-<br />
A, B, C, D, E<br />
or F<br />
-<br />
A, B, C, D, E<br />
or F<br />
-<br />
A, B, C, D, E<br />
or F<br />
-<br />
-<br />
11 MICO 942-3 INT<br />
MD / HSCH 3<br />
3-w ay locking system<br />
w ith manual deadlock<br />
Scandinavian<br />
oval cylinder<br />
Scandinavian<br />
oval cylinder<br />
G, H, I, J, K, L,<br />
M, N or P<br />
12<br />
w ithin the HSCH and panic exit<br />
3 cylinder guard push plate<br />
and lever handle<br />
G<br />
272 20 Nov 2011
13 MICO 942-3 INT<br />
MD<br />
16 MICO 942-3P INT<br />
MD<br />
3-w ay locking system<br />
w ith manual deadlock<br />
3-w ay locking system<br />
w ith manual deadlock<br />
None<br />
None<br />
Scandinavian<br />
oval cylinder<br />
and panic exit<br />
push plate<br />
Scandinavian<br />
oval cylinder<br />
and push pad<br />
14 MICO 942-3P INT 3-w ay locking system Scandinavian<br />
G, H, I, J, K, L,<br />
MD / HSCH 3 w ith manual deadlock oval cylinder<br />
M, N or P<br />
w ithin the HSCH<br />
15<br />
3 cylinder guard<br />
G<br />
and lever handle<br />
Scandinavian<br />
oval cylinder<br />
and push pad<br />
Scandinavian<br />
oval cylinder<br />
and lever handle<br />
17 MICO 942-3L INT 3-w ay locking system Scandinavian<br />
G, H, I, J, K, L,<br />
MD / HSCH 3 w ith manual deadlock oval cylinder<br />
M, N or P<br />
w ithin the HSCH<br />
18<br />
3 cylinder guard<br />
G<br />
and lever handle<br />
19 MICO 942-3L INT<br />
MD<br />
20 MICO 942-3L<br />
EPC INT AD /<br />
HSCH 4<br />
3-w ay locking system<br />
w ith manual deadlock<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
21 MICO 942-3 EPC 3-w ay locking system<br />
INT MD / HSCH 4 w ith manual deadlock<br />
22 MICO 942-3P<br />
EPC INT MD /<br />
HSCH 4<br />
23 MICO 942-3L<br />
EPC INT MD /<br />
HSCH 4<br />
3-w ay locking system<br />
w ith manual deadlock<br />
3-w ay locking system<br />
w ith manual deadlock<br />
None<br />
Europrofile<br />
cylinder w ithin<br />
the HSCH 4<br />
cylinder guard<br />
and lever handle<br />
Europrofile<br />
cylinder w ithin<br />
the HSCH 4<br />
cylinder guard<br />
and lever handle<br />
Europrofile<br />
cylinder w ithin<br />
the HSCH 4<br />
cylinder guard<br />
and lever handle<br />
Europrofile<br />
cylinder w ithin<br />
the HSCH 4<br />
cylinder guard<br />
and lever handle<br />
Scandinavian<br />
oval cylinder<br />
and lever handle<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
lever handle<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
panic exit push<br />
plate<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
push pad<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
lever handle<br />
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
-<br />
-<br />
-<br />
A, B, C, D, E<br />
or F<br />
A, B, C, D, E<br />
or F<br />
A, B, C, D, E<br />
or F<br />
A, B, C, D, E<br />
or F<br />
20 Nov 2011 273
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
24 MICO 942-3L INT 3-w ay locking system Scandinavian Scandinavian G, H, I, J, K, L,<br />
AD / HSCH 4 w ith automatic oval cylinder oval cylinder M, N or P<br />
25<br />
deadlocking<br />
w ithin the HSCH and lever handle<br />
4 cylinder guard<br />
G<br />
and lever handle<br />
26 MICO 942-3 INT<br />
MD / HSCH 4<br />
3-w ay locking system<br />
w ith manual deadlock<br />
Scandinavian<br />
oval cylinder<br />
Scandinavian<br />
oval cylinder<br />
G, H, I, J, K, L,<br />
M, N or P<br />
27<br />
w ithin the HSCH and panic exit<br />
4 cylinder guard push plate<br />
G<br />
and lever handle<br />
28 MICO 942-3P INT 3-w ay locking system Scandinavian Scandinavian G, H, I, J, K, L,<br />
MD / HSCH 4 w ith manual deadlock oval cylinder oval cylinder M, N or P<br />
29<br />
w ithin the HSCH and push pad<br />
4 cylinder guard<br />
G<br />
and lever handle<br />
30 MICO 942-3L INT 3-w ay locking system Scandinavian Scandinavian G, H, I, J, K, L,<br />
MD / HSCH 4 w ith manual deadlock oval cylinder oval cylinder M, N or P<br />
31<br />
w ithin the HSCH and lever handle<br />
4 cylinder guard<br />
G<br />
and lever handle<br />
32 M0455 Surface mounted<br />
barrel bolts<br />
33 Extendor Eclipse<br />
CL03 w ith CL03<br />
cylinder guard<br />
- Europrofile<br />
cylinder w ithin<br />
the CL03 cylinder<br />
guard<br />
- - -<br />
Key (w hen<br />
internal locking<br />
version only)<br />
S, T or U<br />
34 MICO 942 2-w ay panic exit - Panic bar -<br />
device<br />
35 MICO 942P 2-w ay emergency exit - Push pad -<br />
device<br />
36 MICO 942L 2-w ay emergency exit - Lever handle -<br />
device<br />
Compatible Cylinders for Products Compatible with the Securiclad Security Panel System<br />
Cylinder Manufacturer Model Type<br />
Reference<br />
A Abloy Protec CY304 Double Europrofile cylinder (key:key)<br />
B Abloy Disclock Pro CY304 Double Europrofile cylinder (key:key)<br />
C ASSA Tw in 7622 Double Europrofile cylinder (key:key)<br />
D ASSA C5822 Double Europrofile cylinder (key:key)<br />
E ASSA 4822 Double Europrofile cylinder (key:key)<br />
F Kaba Quattro S Euro Double Europrofile cylinder (key:key)<br />
G ASSA 4807 Half Scandinavian oval mechanical cylinder<br />
H ASSA Tw in 7607 Half Scandinavian oval mechanical cylinder<br />
I ASSA C5807 Half Scandinavian oval mechanical cylinder<br />
J ASSA 4407 Half Scandinavian oval mechanical cylinder<br />
K Abloy Protec CY201PT Half Scandinavian oval mechanical cylinder<br />
L Locken CL-PL2WR Half Scandinavian oval mechatronic cylinder<br />
M Kaba Quattro S Oval Half Scandinavian oval mechanical cylinder<br />
N Kaba K20 Oval Half Scandinavian oval mechanical cylinder<br />
O Abloy Disclock Pro CY201DP Half Scandinavian oval mechanical cylinder<br />
P ASSA 4801 Half Scandinavian oval mechanical cylinder<br />
Q ASSA C5801 Half Scandinavian oval mechanical cylinder<br />
R ASSA C5803 Half Scandinavian oval mechanical cylinder<br />
S ASSA dp4400 Single Europrofile cylinder (key)<br />
T CISA AP3S Single Europrofile cylinder (key)<br />
U Kaba Quattro Plus Single Europrofile cylinder (key)<br />
274 20 Nov 2011
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Notes:<br />
1. The Securiclad panel systems must be installed in accordance with the approved Securiclad design manual (ISO/SECG04/02/11) and<br />
compatible product list (ISO/SEC/DSP/15/9/10).<br />
2. The Security Rating attributed to the compatible product must be at least that of the enclosure in which it is to be fitted. For example,<br />
a Security Rating 3 doorset shall not be used to form <strong>part</strong> of a Security Rating 4 enclosure.<br />
3. Refer to notes contained within the relevant certificate/Red Book entries for these products for details of restrictions on their use.<br />
Liddle Doors Limited<br />
Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom<br />
Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698<br />
E-mail: liddle@liddledoors.co.uk • Website: www.liddledoors.co.uk<br />
Certificate No: 442e to LPS 1175: Issue 6<br />
Security Cabinet (Wall Mounted)<br />
Product Name Model Nominal Cabinet<br />
Height (mm)<br />
Nominal Cabinet<br />
Width (mm)<br />
Nominal Cabinet<br />
Depth (mm)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
Liddle Series 2 Size 1 wall mounted 400 460 240 2 442e/01<br />
Security Box security cabinet<br />
Size 2 wall mounted 400 400 150 2<br />
Liddle Series 3<br />
Security Box<br />
security cabinet<br />
Size 1 wall mounted<br />
security cabinet<br />
Size 2 wall mounted<br />
security cabinet<br />
400 460 240 3 442e/02<br />
400 400 150 3<br />
Compatible Padlocks<br />
Padlock Designation Cylinder LPCB Ref. No 442e/<br />
1 2<br />
Abloy PL340/25 Abloy Disklock Pro <br />
Notes:<br />
1. The security boxes are approved when wall mounted directly to brickwork, concrete or steel. The approval does not cover the security<br />
boxes when mounted to alternative substrates or via intermediate substrates such as plasterboard.<br />
2. Certification does not cover the use of padlocks other than those listed above. Utilisation of unlisted padlocks may affect the level of<br />
security offered by the product.<br />
Lowrey Contractors Limited<br />
200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom<br />
Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111<br />
E-mail: lowrey@talk21.com • Website: www.lowrey-contractors.co.uk<br />
Certificate No: 974b to LPS 1175: Issue 7<br />
Modular Security Cage System<br />
Product<br />
Name<br />
Type Minimum<br />
Height<br />
(m)<br />
Lowrey Level<br />
1 Security<br />
Mesh Panel<br />
System<br />
Lowrey Level<br />
2 Security<br />
Mesh Panel<br />
System<br />
Cage<br />
formed from<br />
four sides<br />
and a ceiling<br />
Cage<br />
formed from<br />
four sides<br />
and a ceiling<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m) 1<br />
Maximum<br />
Width (m)<br />
Minimum<br />
Depth<br />
(m)<br />
Maximum<br />
Depth<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.1 3.91 0.5 Unlimited 0.5 4.0 1 974b/01<br />
1.1 3.91 0.5 Unlimited 0.5 4.0 2 974b/02<br />
20 Nov 2011 275
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Product<br />
Name<br />
Lowrey Level<br />
3 Security<br />
Mesh Panel<br />
System<br />
Type<br />
Cage<br />
formed from<br />
four sides<br />
and a ceiling<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m) 1<br />
Maximum<br />
Width (m)<br />
Minimum<br />
Depth<br />
(m)<br />
Maximum<br />
Depth<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.1 3.91 0.5 Unlimited 0.5 4.0 3 974b/03<br />
System Components<br />
Component Type Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Wall panel Mesh w all panel 0.25 2.4 0.5 1.5 N/A N/A<br />
Roof panel Mesh roof panel N/A N/A 0.25 1.5 0.25 3.8<br />
Support post<br />
Corner post<br />
Doorsets<br />
Support post for 1.0 3.8 0.215 0.215 N/A N/A<br />
w alling system<br />
270 degree corner 1.1 3.91 0.125 0.125 N/A N/A<br />
post for w alling<br />
system<br />
90 degree corner 1.1 3.91 0.11 0.11 N/A N/A<br />
post for w alling<br />
system<br />
Single leaf outw ard<br />
opening doorset<br />
Refer to ‘Low rey Level 1, 2 and 3’ single leaf mesh security doorsets (LPCB<br />
Ref. No. 974a/01, 03 and 05) for scope of approval.<br />
Double leaf outw ard Refer to ‘Low rey Level 1, 2 and 3’ double leaf mesh security doorsets (LPCB<br />
opening doorset Ref. No. 974a/02, 04 and 06) for scope of approval.<br />
Notes:<br />
1. The minimum width of an enclosure wall incorporating a doorset is 0.63 m.<br />
2. The cage’s resistance relies on the supporting substrate offering compatible resistance to manual attack.<br />
3. The Lowrey security mesh panel system is approved when installed in accordance with the instructions detailed on Lowrey’s<br />
document E-INST001 (Issue 3).<br />
Certificate No: 974e to LPS 1175: Issue 7<br />
Modular Security Enclosure System<br />
Product<br />
Name<br />
Product<br />
Type<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height (m)<br />
Lowrey<br />
Level 4<br />
Security<br />
Solid<br />
Panel<br />
System<br />
Enclosure<br />
formed from<br />
four sides<br />
and a<br />
ceiling<br />
Minimum<br />
Width<br />
(m) 1<br />
Maximum<br />
Width (m)<br />
Minimum<br />
Depth (m)<br />
Maximum<br />
Depth (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.1 3.91 0.5 Unlimited 0.5 4.0 4 974e/01<br />
System Components<br />
276 20 Nov 2011
Component Type Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Wall panel Solid w all panel 0.25 2.4 0.5 1.5 N/A N/A<br />
Roof panel Solid roof panel N/A N/A 0.25 1.5 0.25 3.8<br />
Support post<br />
Corner post<br />
Doorsets<br />
Support post for<br />
w alling system<br />
270 degree<br />
corner post for<br />
w alling system<br />
90 degree corner<br />
post for w alling<br />
system<br />
Single leaf<br />
outw ard opening<br />
plain leaf doorset<br />
Double leaf<br />
outw ard opening<br />
plain leaf doorset<br />
1.0 3.8 0.215 0.215 N/A N/A<br />
1.1 3.91 0.125 0.125 N/A N/A<br />
1.1 3.91 0.11 0.11 N/A N/A<br />
Refer to ‘Low rey Level 4’ single leaf security doorsets (LPCB Ref. No.<br />
974d/01) for scope of approval.<br />
Refer to ‘Low rey Level 4’ double leaf security doorsets (LPCB Ref. No.<br />
974d/02) for scope of approval.<br />
Notes:<br />
1. The minimum width of an enclosure wall incorporating a doorset is 0.63 m.<br />
2. The enclosures resistance relies on the supporting substrate offering compatible resistance to manual attack.<br />
3. The Lowrey security solid panel system is approved when installed in accordance with the instructions detailed on Lowrey’s document<br />
E-INST001 (Issue 3).<br />
Morgan Marine Limited<br />
Llandybie, Ammanford, Carmarthenshire SA18 3GY, United Kingdom<br />
Tel: +44 (0)1269 850437 • Fax: +44 (0)1269 850656<br />
E-mail: sales@morgan-marine.com • Website: www.morgan-marine.com<br />
Certificate No: 1051a to LPS 1175: Issue 7<br />
Security Enclosures<br />
Product<br />
Name<br />
Product<br />
Type<br />
Nominal<br />
Minimum<br />
Height 1<br />
(m)<br />
Morgan<br />
Titan<br />
SR2<br />
Morgan<br />
Titan<br />
SR3<br />
GRP<br />
security<br />
enclosure<br />
GRP<br />
security<br />
enclosure<br />
Nominal<br />
Maximum<br />
Height 1<br />
(m)<br />
Nominal<br />
Minimum<br />
External<br />
Width (m)<br />
Nominal<br />
Maximum<br />
External<br />
Width (m)<br />
Nominal<br />
Minimum<br />
External<br />
Length<br />
(m)<br />
Nominal<br />
Maximum<br />
External<br />
Length (m)<br />
Security<br />
Rating<br />
Cert. No.<br />
<strong>2.2</strong>1 5.0 1.0 2 14.0 1.0 2 30.0 2 1051a/01<br />
<strong>2.2</strong>1 5.0 1.0 2 14.0 1.0 2 30.0 3 3 1051a/02<br />
Compatible Doorsets<br />
Manufacturer Model Type Structural<br />
Opening<br />
Structural<br />
Opening<br />
Compatible Locking<br />
Systems<br />
LPCB Ref.<br />
No.<br />
Height (m ) Width (m) Active<br />
Leaf<br />
Passive<br />
Leaf<br />
PSF Wales Hercules Single leaf outw ard 2.12 1.12 1 and 2 N/A 953a/01<br />
Limited SAF3 opening hinged doorset<br />
PSF Wales<br />
Limited<br />
Hercules<br />
SAF3<br />
Double leaf outw ard<br />
opening hinged doorset<br />
<strong>2.2</strong>1 <strong>2.2</strong>1 1 and 2 3 953a/02<br />
Locking Options Available on the Compatible Doorsets<br />
20 Nov 2011 277
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Com patible<br />
Locking<br />
System<br />
1 Tindall<br />
Engineering<br />
2 Tindall<br />
Engineering<br />
3 Commercial<br />
Body Fittings<br />
Limited<br />
Cylinders Options<br />
Manufacturer Model / Type Operation Compatible<br />
Cylinders<br />
Entry<br />
Exit<br />
Mico 942-3L INT AD / USCH4<br />
three-point auto-deadlocking autobolting<br />
system w ith external<br />
cylinder access<br />
Mico 942-3L INT MD / USCH4<br />
three-point manual-deadlocking<br />
auto-bolting system w ith external<br />
cylinder access<br />
USCH4 cylinder<br />
guard incorporating<br />
a Scandinavian oval<br />
cylinder<br />
USCH4 cylinder<br />
guard incorporating<br />
a Scandinavian oval<br />
cylinder<br />
Thumbturn and<br />
lever handle<br />
Thumbturn and<br />
lever handle<br />
Sprung tow er bolt - Tw o sprung tow er<br />
bolts 3<br />
Cylinder Manufacturer Model Type<br />
Reference<br />
A Abloy Disclock Pro CY201DP Mechanical Scandinavian oval cylinder<br />
B Assa 4807 Mechanical Scandinavian oval cylinder<br />
C Assa C5807 Mechanical Scandinavian oval cylinder<br />
D Assa Tw in 7607 Mechanical Scandinavian oval cylinder<br />
E Kaba K20 Oval Mechanical Scandinavian oval cylinder<br />
F Kaba Quattro S Oval Mechanical Scandinavian oval cylinder<br />
G Locken CL-PL2WR Mechatronic Scandinavian oval cylinder 4<br />
A to G<br />
A to G<br />
N/A<br />
Approved Optional Design Features<br />
Optional Design Feature<br />
Reference Revision /<br />
Date<br />
Removable roof MDS017 C<br />
22/7/11<br />
Shrouded vents w ith cow ls measuring 0.45 m w ide by 0.45 m high by 0.45 m deep 5,6<br />
Associated Drawing<br />
MDS015<br />
(Sheet 2)<br />
F<br />
22/7/11<br />
Notes:<br />
1. The height is measured from the ground to the underside of the roof panel.<br />
2. This is the minimum length/width of the enclosure when the enclosure does not incorporate a doorset in that plane. The minimum<br />
length/width of the enclosure when it incorporates a doorset within that plane is 1.39 m (single leaf doorset fitted) or 2.39 m (double<br />
leaf doorset fitted).<br />
3. The Morgan Titan SR3 enclosures incorporating double leaf doorsets achieve Security Rating 3 when both sprung tower bolts on the<br />
passive leaf are engaged and the lock mechanism fitted to the primary leaf is engaged and deadlocked. A Security Rating 1<br />
classification prevails if one of the sprung tower bolts on the passive leaf is not engaged.<br />
4. The resistance of the electronic cylinder to ‘non-mechanical’ attack is outside the scope of this approval because it is outside the<br />
scope of LPS1175: Issue 7. Likewise, this approval does not cover the possible effects of any susceptibilities relating to the<br />
functionality and performance of the keys that may be used to operate the cylinder. It is therefore recommended that specifiers and<br />
installers satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse and are<br />
resistant to any environmental conditions/interference that may cause the lock to disengage.<br />
5. The approval does not cover the provision of any other apertures within the fabric of the enclosure, e.g. for ventilation or other<br />
services, other than that provided by the shrouded vent listed in the list of approved optional design features.<br />
6. The shrouded vents must be located at least 0.3 m away from the thumbturns and lever handles present on Hercules SAF3 doorsets<br />
when fitted within the same plane as the doorset, and 0.4 m away from the thumbturns and lever handles present on Hercules SAF3<br />
doorsets when located in a wall that is perpendicular to the plane of the doorset.<br />
7. The approval covers the enclosures when installed onto stepped concrete bases of equivalent resistance to attack, using the method<br />
of installation defined on drawing MDS 015 (Revision F dated 22 July 2011).<br />
278 20 Nov 2011
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Professional Barrier Systems Limited<br />
16 Stapledon Road, Orton Southgate, Peterborough PE2 6TD, United Kingdom<br />
Tel: +44 (0)1733 361511 • Fax: +44 (0)1733 361512<br />
E-mail: mail@extendor.co.uk • Website: www.extendor.co.uk<br />
Certificate No: 869b to LPS 1175: Issue 6<br />
Modular Security Cages<br />
Product<br />
Name<br />
Type Minimum<br />
Height<br />
(m)<br />
Extendor<br />
Eclipse<br />
Maximum<br />
Height (m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Modular<br />
cage formed<br />
from<br />
Extendor<br />
Eclipse fixed<br />
and opening<br />
grilles 1 0.715 3.67 3, 4 0.48 Unlimited 2,<br />
5<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
1.0 Unlimited 2,<br />
5<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
3 869b/01<br />
System Components<br />
Component Type<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Wall panel 4 0.625 3.58 0.3 3.06 N/A N/A<br />
Roof panel N/A N/A 0.3 3.06 0.625 3<br />
Doorset 7 0.625 2.7 1 3.025 N/A N/A<br />
Notes:<br />
1. Cages are rectilinear in plan and not limited to a simple rectangle. That is approval covers cages with acute and obtuse vertical<br />
corners.<br />
2. The maximum sizes of the cage are subject to specific assessment of physical restrictions and operational conditions.<br />
3. The maximum height of any opening sash within the cage is 2.7 m. Cages above this height incorporate a fixed grille.<br />
4. Wall panels can be coupled vertically to form cage height.<br />
5. The maximum clear span is 4 m. Spans greater than this require support column(s).<br />
6. For details of locking options and accessories approved refer to certificate 869a/01.<br />
7. The certification covers the installation of the cage directly to a concrete floor 8 .<br />
8. The cages can also be secured onto raised floors. This is providing the cage extends under the raised floor to a concrete floor<br />
beneath it. The wall panels located under the raised floor shall be bolted to the underside of the wall panels located above the floor,<br />
sandwiching the floor panels between them. The wall panels located under the raised floor shall also be directly fixed to the concrete<br />
floor beneath the cage.<br />
PSF Wales Limited<br />
Llys Rhiannon, Cil Yr Ychen Industrial Estate, Landeilo Road, Llandybie, Ammanford, Carmarthenshire SA18<br />
3GY, United Kingdom<br />
Tel: +44 (0)1269 851777 • Fax: +44 (0)1269 851747<br />
E-mail: sales@psfwales.co.uk • Website: www.psfwales.co.uk<br />
Certificate No: 953b to LPS 1175: Issue 6<br />
20 Nov 2011 279
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Modular Security Enclosures<br />
Product<br />
Name<br />
Product<br />
Type<br />
Nominal<br />
Minimum<br />
External<br />
Height<br />
(m)<br />
Hercules<br />
SAF 3<br />
Hercules<br />
SAF 4<br />
Nominal<br />
Maximum<br />
External<br />
Height (m)<br />
Nominal<br />
Minimum<br />
External<br />
Width (m)<br />
Nominal<br />
Maximum<br />
External<br />
Width (m)<br />
Nominal<br />
Minimum<br />
External<br />
Depth (m)<br />
Nominal<br />
Maximum<br />
External<br />
Depth (m)<br />
Security<br />
Rating<br />
Modular 2.3 3.8 1.73 25 1.0 10 3 953b/01<br />
doorset 1<br />
enclosure<br />
with single<br />
leaf<br />
outward<br />
opening<br />
Modular<br />
enclosure<br />
with double<br />
leaf<br />
outward<br />
opening<br />
doorset 2 2.3 3.8 2.78 25 1.0 10 3 953b/02<br />
Modular 2.3 3.8 1.73 25 1.0 10 4 953b/03<br />
doorset 3<br />
enclosure<br />
with single<br />
leaf<br />
outward<br />
opening<br />
Modular 2.3 3.8 2.78 25 1.0 10 4 953b/04<br />
doorset 4<br />
enclosure<br />
with double<br />
leaf<br />
outward<br />
opening<br />
Cert.<br />
No.<br />
Approved Accessories<br />
Accessory<br />
Hercules SAF 3 and 4 Enclosure (LPCB Ref. No. 953b/..)<br />
01 02 03 04<br />
Shrouded vents (200 mm high by 350 mm w ide) 5 <br />
Fixed roof <br />
Removable roof <br />
Notes:<br />
1. The approval covers the use of the Hercules SAF 3 single leaf doorsets (LPCB reference number 953a/01).<br />
2. The approval covers the use of the Hercules SAF 3 double leaf doorsets (LPCB reference number 953a/02).<br />
3. The approval covers the use of the Hercules SAF 4 single leaf doorsets (LPCB reference number 953a/03).<br />
4. The approval covers the use of the Hercules SAF 4 double leaf doorsets (LPCB reference number 953a/04).<br />
5. The vents shall not be located within 1.2 m of the locks on doorsets fitted to the enclosure.<br />
6. The approval covers the Hercules SAF 3 and 4 enclosures when installed in accordance with the ‘Installation instructions for Hercules<br />
SAF kiosk’ dated 2 February 2010.<br />
Certificate No: 953c to LPS 1175: Issue 7<br />
Security Enclosures<br />
Product Product<br />
Name Type<br />
Hercules<br />
SAF 2<br />
Security<br />
enclosure<br />
with integral<br />
single or<br />
double leaf 1<br />
padlockable<br />
doorset<br />
Nominal<br />
Minimum<br />
External<br />
Height<br />
(m)<br />
Nominal<br />
Maximum<br />
External<br />
Height (m)<br />
Nominal<br />
Minimum<br />
External<br />
Width (m)<br />
Nominal<br />
Maximum<br />
External<br />
Width (m)<br />
Nominal<br />
Minimum<br />
External<br />
Depth (m)<br />
Nominal<br />
Maximum<br />
External<br />
Depth (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.8 2.8 0.63 2.8 0.375 2.8 2 2 953c/01<br />
Compatible Padlocks<br />
280 20 Nov 2011
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Manufacturer Model Cylinder<br />
Abloy PL340/25 DP Abloy Disclock Pro<br />
Abloy PL340/25 PT Abloy Protec<br />
Abloy PL342 DP Abloy Disclock Pro<br />
Abloy PL342 PT Abloy Protec<br />
Accessories<br />
Type<br />
Shrouded vent w ith integrated<br />
vermin mesh.<br />
Description<br />
The shroud has external dimensions 300 mm (major height) by 200 mm (minor height) by 356 mm<br />
(w idth) by 100 mm (depth). It incorporates a 56 mm w ide by 312 mm long ventilation slot in the<br />
bottom fitted w ith a 100 mm by 100 mm vermin mesh.<br />
Notes:<br />
1. The scope of approval covers doorsets formed with leafs of widths between 0.35 m and 1.3 m and heights between 0.7 m and 2.8 m<br />
secured using the padlocks listed in the compatible padlock <strong>section</strong>.<br />
2. The security rating on the double doorset version of the security enclosure is achieved when both bolts on the passive leaf are<br />
engaged, the multi-point lock mechanism fitted to the primary leaf engaged and padlocked using one of the padlocks listed in the<br />
compatible padlock <strong>section</strong>. The double doorset version of the security enclosure achieved Security Rating 1 if only one of the tower<br />
bolts on the passive leaf was engaged.<br />
3. The approval does not cover the provision of any apertures within the enclosure fabric, other than the integral doorset or the<br />
shrouded vent described in the accessories <strong>section</strong>.<br />
4. The approval covers the Hercules SAF 2 pre-fabricated security enclosures when installed directly onto a concrete plinth in<br />
accordance with the instructions contained on PSF Wales Limited’s document SR2 K2 dated 29 March 2011.<br />
R & D Sheetmetal Limited<br />
Unit 1A, Victoria Court, Colliers Way, Clayton West, Huddersfield, West Yorkshire HD8 9TR, United Kingdom<br />
Tel: +44 (0)1484 864886 • Fax: +44 (0)1484 866505<br />
E-mail: sales@randdsheetmetal.co.uk • Website: www.randdsheetmetal.co.uk<br />
Certificate No: 1034a to LPS 1175: Issue 7<br />
Modular Security Enclosure<br />
Product<br />
Name<br />
Product<br />
Type<br />
Minimum<br />
Height<br />
(m)<br />
Security<br />
Evo IV<br />
Security<br />
Evo V<br />
Security<br />
Evo VI<br />
Enclosure<br />
formed from<br />
four sides<br />
and a ceiling<br />
Enclosure<br />
formed from<br />
four sides<br />
and a ceiling<br />
Enclosure<br />
formed from<br />
four sides<br />
and a ceiling<br />
Maximum<br />
Height (m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Minimum<br />
Depth (m)<br />
Maximum<br />
Depth (m)<br />
Security<br />
Rating<br />
Cert. No.<br />
1.9 2.7 1.1 2.4 0.8 Unlimited 4 1034a/01<br />
1.9 2.7 1.1 2.4 0.8 Unlimited 5 1034a/02<br />
1.9 2.7 1.1 2.4 0.8 Unlimited 6 1034a/03<br />
System Components<br />
20 Nov 2011 281
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Component Type Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Minimum<br />
Depth<br />
(m)<br />
Maximum<br />
Depth<br />
(m)<br />
Wall panel Wall panel 1.8 2.35 0.25 1.1 N/A N/A<br />
Roof panel<br />
Single roof panel 0.1 0.35 1.1 2.4 0.8 1.05<br />
End roof panel 0.1 0.35 1.1 2.4 0.25 1.05<br />
Mid roof panel 0.1 0.35 1.1 2.4 0.25 1.1<br />
Corner post Corner post 1.8 2.35 0.1 0.35 N/A N/A<br />
Doorsets 1<br />
Single leaf outw ard<br />
opening doorset<br />
Refer to Security Evo doorset range (LPCB Ref. No. 1034b) for scope of<br />
approval.<br />
Notes:<br />
1. Certification does not cover the use of locks other than those listed for use with the relevant R&D Sheetmetal Limited doorset.<br />
Utilisation of unlisted locks may affect the level of security offered by the doorset fitted to the enclosure.<br />
2. The enclosure’s resistance relies on the supporting substrate offering compatible resistance to manual attack.<br />
3. The Security Evo enclosure system is approved when installed in accordance with the instructions detailed on document EVO-INST-<br />
01 (Issue 3) and the general arrangement drawings supplied with the product.<br />
Technocover Limited (incorporating TechnoRail and Strataform)<br />
Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom<br />
Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527<br />
E-mail: techadvice@technocover.co.uk • Website: www.technocover.co.uk<br />
Certificate No: 450b to LPS 1175: Issue 5<br />
Security Cabinets<br />
Product Name<br />
Half Location Apparatus<br />
Case (LAC/H)<br />
Full Location Apparatus<br />
Case (LAC/F)<br />
Half Location Apparatus<br />
Case (LAC/H)<br />
Full Location Apparatus<br />
Case (LAC/F)<br />
Nominal Enclosure<br />
Height (mm)<br />
Nominal Enclosure<br />
Width (mm)<br />
Nominal Enclosure<br />
Depth (mm)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1850 575 535 3 450b/01<br />
1850 1010 535 3 450b/02<br />
1850 575 535 4 450b/03<br />
1850 1010 535 4 450b/04<br />
Compatible Padlocks<br />
Padlock Designation Cylinder LPCB Ref. No 450b/…<br />
1 2 3 4<br />
Abloy PL240/25 Abloy High profile <br />
Abloy PL240/25EX Abloy Exec <br />
Abloy PL240/25DP Abloy Disklock Pro <br />
Abloy PL240/25PT Abloy Protec <br />
Abloy PL242 Abloy High Profile <br />
Abloy PL242EX Abloy Exec <br />
Abloy PL242DP Abloy Disklock Pro <br />
Abloy PL242PT Abloy Protec <br />
Abloy PL250/25 Abloy High Profile <br />
Abloy PL250/25EX Abloy Exec <br />
Abloy PL250/25DP Abloy Disklock Pro <br />
Abloy PL250/25PT Abloy Protec <br />
Abloy PL340 Abloy High Profile <br />
Abloy PL340EX Abloy Exec <br />
Abloy PL340DP Abloy Disklock Pro <br />
282 20 Nov 2011
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Abloy PL340PT Abloy Protec <br />
Abloy PL342 Abloy High Profile <br />
Abloy PL342EX Abloy Exec <br />
Abloy PL342DP Abloy Disklock Pro <br />
Abloy PL342PT Abloy Protec <br />
Abloy PL350/25 Abloy High Profile <br />
Abloy PL350/25EX Abloy Exec <br />
Abloy PL350/25DP Abloy Disklock Pro <br />
Abloy PL350/25PT Abloy Protec <br />
Chubb 1K23c Chubb 6-pin <br />
Kaba KP15.0000C5-RB Kaba 20 (Armoured) 3 <br />
Kaba K20SS65L Kaba 20 (Armoured) 3 <br />
Kaba K20SS65CL Kaba 20 (Armoured) 3 <br />
Rotalok 60/12/SE Kaba 20 (Armoured) 3 <br />
Rotalok 60/12/SE Kaba 20 (Standard) 3 <br />
Rotalok 60/12/ST Abloy Disklock Pro <br />
Rotalok 60/12/ST Abloy Exec <br />
Rotalok 60/12/ST Abloy Protec <br />
Rotalok 60/12/ST-T027 Assa Tw in-Combi <br />
Rotalok 60/12/ST Kaba 20 (Armoured) 3 <br />
Rotalok 60/12/ST Kaba 20 (Standard) 3 <br />
Notes:<br />
1. Certification does not cover the use of padlocks other than those listed above. Utilisation of unlisted padlocks may affect the level of<br />
security offered by the enclosure.<br />
2. The ‘user friendliness’ of employing the padlocks listed above has not been assessed as this is beyond the scope of LPS1175: Issue<br />
5.<br />
3. The torque resistant version of the Kaba 20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders.<br />
Certificate No: 450c to LPS 1175: Issue 5<br />
Modular Security Cabinets and Building Systems<br />
Product<br />
Name<br />
Product Type Minimum<br />
Height<br />
(mm)<br />
Maximum<br />
Height<br />
(mm)<br />
Minimum<br />
Width<br />
(mm)<br />
WMC/DV4 Walk-In<br />
Modular<br />
Building<br />
System<br />
CB1/DV4 Small modular<br />
secure<br />
cabinet system<br />
with<br />
single leaf<br />
doorset<br />
CB2/DV4 Small modular<br />
secure<br />
cabinet system<br />
with<br />
double leaf<br />
doorset<br />
WMC/DV3 Walk-in<br />
modular<br />
building<br />
system<br />
CB1/DV3 Small modular<br />
secure cabinet<br />
system with<br />
single<br />
leaf doorset<br />
CB2/DV3 Small modular<br />
secure cabinet<br />
system with<br />
double<br />
leaf doorset<br />
Maximum<br />
Width<br />
(mm)<br />
Minimum<br />
Depth<br />
(mm)<br />
Maximum<br />
Depth<br />
(mm)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1500 3000 1000 5000 1000 10000 4 450c/01<br />
900 2000 650 5000 450 1500 4 450c/02<br />
900 2000 1350 5000 450 1500 4 450c/03<br />
1500 3000 1000 4000 1000 10000 3 450c/04<br />
900 2000 650 5000 450 1500 3 450c/05<br />
900 2000 1350 5000 450 1500 3 450c/06<br />
System Components<br />
20 Nov 2011 283
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Component<br />
Wall panels<br />
Roof panels<br />
Doorsets 1<br />
Type<br />
Minimum<br />
Height<br />
(mm)<br />
Maximum<br />
Height<br />
(mm)<br />
Minimum<br />
Width<br />
(mm)<br />
Maximum<br />
Width<br />
(mm)<br />
Minimum<br />
Depth<br />
(mm)<br />
Maximum<br />
Depth<br />
(mm)<br />
LPCB Ref No: 450c/…<br />
01 02 03 04 05 06<br />
Side panel 900 3000 450 1200 N/A N/A <br />
Side corner panel 900 3000 450 1200 N/A N/A <br />
Single piece side 900 2000 650 1800 450 1025<br />
panel 2 <br />
Capping panel 3 150 2100 500 2600 N/A N/A <br />
"Security Rating 4" N/A N/A 450 1200 510 5060<br />
central roof panel<br />
<br />
"Security Rating 3" N/A N/A 450 1200 510 4060<br />
central roof panel<br />
<br />
"Security Rating 4" N/A N/A 450 1200 510 5060<br />
end roof panel<br />
<br />
"Security Rating 3" N/A N/A 450 1200 510 4060<br />
end roof panel<br />
<br />
'One piece' roof N/A N/A 510 1200 710 5060<br />
panel<br />
<br />
Single leaf<br />
outw ard opening<br />
doorset<br />
Double leaf<br />
outw ard opening<br />
doorset<br />
Single leaf<br />
outw ard opening<br />
doorset<br />
Single leaf<br />
outw ard opening<br />
doorset<br />
Double leaf<br />
outw ard opening<br />
doorset<br />
For dimensions, please refer to UltraSecure DS1/DV4 doorset (LPCB Ref.<br />
No. 450a/03)<br />
For dimensions, please refer to UltraSecure DS2/DV4 doorset (LPCB Ref.<br />
No. 450a/08)<br />
For dimensions, please refer to UltraSecure DS1/DV3 doorset (LPCB Ref.<br />
No. 450d/01)<br />
For dimensions, please refer to UltraSecure DS1/LS3 doorset (LPCB Ref.<br />
No. 450d/02) 4<br />
For dimensions, please refer to UltraSecure DS2/DV3 doorset (LPCB Ref.<br />
No. 450d/03)<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Approved Accessories<br />
Accessory<br />
LPCB Ref. No. 450c/…<br />
01 02 03 04 05 06<br />
Louvre vents 5 <br />
Ultrasecure DV single, tw in or triple leaf access covers 6 <br />
Notes:<br />
1 Certification does not cover the use of locks other than those listed for use with the relevant Technocover doorsets (LPCB Ref. No’s.<br />
450a/03 and 08, and 450d/01, 02 and 03). Utilisation of unlisted locks may affect the level of security offered by the doorset(s) fitted<br />
to the cabinet.<br />
2 Combined maximum size of panel is restricted by material availability. Refer to manufacturer before ordering.<br />
3 The following constraints apply to capping panel:<br />
a. If the panel height is less than 1200 mm, the maximum panel width is 2600 mm.<br />
b. If the panel height is greater than 1200 mm, the maximum panel width is 1200 mm.<br />
4 The following constraints apply when the UltraSecure DS1/LS3 door is fitted to CB1 cabinets or WMC modular buildings:<br />
a. Cabinet depth shall be at least 800 mm.<br />
b. Cabinet height shall be at least 1200 mm.<br />
c. Minimum distance on width side from leading edge of door leaf to side of cabinet is 625 mm.<br />
5 A maximum of six louvre vents may be fitted to each panel.<br />
6 The access covers fall within the scope of LPCB Ref. No’s. 450a/01, 02, 04, 05, 06 and 07. However, the maximum internal opening<br />
width is restricted to 1100 mm.<br />
Certificate No: 450i to LPS 1175: Issue 7<br />
284 20 Nov 2011
Modular Security Cage System<br />
Product<br />
Name<br />
Product Type Minimum<br />
Height<br />
(m)<br />
Ultrasecure<br />
security cage<br />
system<br />
Cage formed<br />
from one side<br />
and a ceiling<br />
supported by<br />
existing<br />
adjacent walls<br />
Cage formed<br />
from two sides<br />
supported by<br />
existing<br />
adjacent walls<br />
Cage formed<br />
from two sides<br />
and a ceiling<br />
supported by<br />
existing<br />
adjacent walls<br />
Cage formed<br />
from three<br />
sides<br />
supported by<br />
existing<br />
adjacent walls<br />
Cage formed<br />
from three<br />
sides and a<br />
ceiling<br />
supported by<br />
existing<br />
adjacent walls<br />
Cage formed<br />
from three<br />
sides<br />
supported by<br />
existing<br />
adjacent walls<br />
Cage formed<br />
from four sides<br />
and a ceiling<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Minimum<br />
Depth<br />
(m)<br />
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Maximum<br />
Depth<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.50 1 6 0.50 2 Unlimited 0.50 2 6 3 450i/01<br />
0.50 1 6 0.63 2 Unlimited 0.63 2 Unlimited 3<br />
0.50 1 6 0.63 2 Unlimited 0.63 2 6 3<br />
0.50 1 6 0.76 2 Unlimited 0.63 2 Unlimited 3<br />
0.50 1 6 0.76 2 Unlimited 0.63 2 6 3<br />
0.50 1 6 0.76 2 Unlimited 0.63 2 Unlimited 3<br />
0.50 1 6 0.76 2 Unlimited 0.76 2 6 3<br />
System Components<br />
Component Type Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Wall panel Mesh w all panel 0.50 6 0.25 1 N/A N/A<br />
Roof panel Mesh roof panel N/A N/A 0.25 1 0.50 6<br />
Corner post Corner post for cage 0.50 6 0.13 0.13 N/A N/A<br />
system<br />
Support post Support post for cage 0.46 5.91 0.165 0.165 N/A N/A<br />
system<br />
Doorsets Single leaf outw ard<br />
opening doorset<br />
Double leaf outw ard<br />
opening doorset<br />
Refer to Ultrasecure SCD1 mesh security doorset (LPCB Ref. No. 450j/01) for<br />
scope of approval.<br />
Refer to Ultrasecure SCD2 mesh security doorset (LPCB Ref. No. 450j/02) for<br />
scope of approval.<br />
Notes:<br />
1. The minimum height of enclosures incorporating a doorset is 1.08 m.<br />
2. The minimum length of a side wall incorporating doorsets is 0.63 m.<br />
3. The cage’s resistance relies on the supporting substrate offering compatible resistance to manual attack.<br />
4. The Ultrasecure security cage system is approved when installed in accordance with the instructions detailed on document SCS-DV-<br />
3-FIT-01 (Ref.B).<br />
20 Nov 2011 285
PART 4: SECTION 4<br />
SECURE ENCLOSURES<br />
Trimetals Limited<br />
Sunrise Business Park, Higher Shaftesbury Road, Blandford Forum, Dorset DT11 8ST, United Kingdom<br />
Tel: +44 (0)1258 459441 • Fax: +44 (0)1258 480408<br />
E-mail: sales@trimetals.co.uk • Website: www.trimetals.co.uk<br />
Certificate No: 899a to LPS 1175: Issue 6<br />
Bicycle and Motorcycle Store<br />
Product Name Type Model Nominal<br />
Internal<br />
Height 1<br />
Nominal<br />
Internal<br />
Width<br />
(m)<br />
Nominal<br />
Internal<br />
Depth<br />
(m)<br />
Security<br />
Rating<br />
Cert. No.<br />
(m)<br />
Protect a Cycle Bicycle store - 1.28 1.8 0.84 1 2 899a/01<br />
Protect a Bike Motorcycle store Standard pent roof model 2.0 1.4 2.7 2 3 899a/02<br />
Motorcycle store Wide pent roof model 2.0 1.6 2.7 2 3<br />
Motorcycle store Extra wide pent roof model 2.0 1.7 2.7 2 3<br />
Compatible Locking Devices<br />
Product Name Locking Device Manufacturer Model Description<br />
Protect a Cycle<br />
Protect a Bike<br />
Ground anchor 4<br />
Padlock 4<br />
Security cable 4<br />
Ground anchor 5<br />
Chain/padlock 5<br />
Oxford Products<br />
Limited<br />
Oxford Products<br />
Limited<br />
IR Safety and<br />
Security<br />
Oxford Products<br />
Limited<br />
Oxford Products<br />
Limited<br />
Oxford BruteForce<br />
(OF439)<br />
Oxford HD Mini (OF161)<br />
7 ft KryptoFlex Looped<br />
Cable (210610)<br />
Oxford RotaForce<br />
(OF438)<br />
Oxford Hardcore XL<br />
(OF118)<br />
Ground anchor<br />
Mini ‘U-lock’ padlock<br />
10 mm diameter by <strong>2.2</strong> m double<br />
looped security cable<br />
Ground anchor<br />
Security chain and padlock set<br />
Approved Installation Configurations<br />
Product Name<br />
Protect a Cycle<br />
Protect a Bike<br />
Configuration<br />
Mounted directly onto a flat level concrete surface at least 100 mm thick, in accordance<br />
w ith the ‘Protect a cycle assembly instructions’ (Issue 1 dated 6 October 2008)<br />
Mounted directly onto a flat level concrete surface at least 100 mm thick, in accordance<br />
w ith the ‘Pent roof shed assembly instructions’<br />
Notes:<br />
1. This is the enclosure’s nominal internal height at the peaked <strong>section</strong> of the roof.<br />
2. The security rating relates to resistance to removal of complete bicycles, of designs incorporating enclosed frames (e.g. ‘diamond’,<br />
‘parallel top tube’, ‘single diagonal’, ‘mixte’ and ‘berceau’), that are secured within the ‘Protect a cycle’ bicycle store in accordance<br />
with the ‘Protect a cycle assembly instructions’ (Issue 1 dated 6 October 2008).<br />
3. The security rating relates to resistance to removal of complete motorcycles that are secured within the ‘Protect a bike’ motorcycle<br />
store in accordance with the ‘Trimetals Titan Range roof shed assembly instructions’.<br />
4. These locking devices must always be used to secure the bicycles within the security enclosure in order to achieve the security rating<br />
attributed to the ‘Protect a Cycle’ bicycle store. The cable should be passed through the centre of the bicycle frame and looped<br />
through the ground anchor and the two looped ends of the cable should both be secured using the padlock provided, as illustrated in<br />
‘step 15’ of the ‘Protect a cycle assembly instructions’ (Issue 1 dated 6 October 2008).<br />
5. These locking devices must always be used to secure the motorcycles within the security enclosure in order to achieve the security<br />
rating attributed to the ‘Protect a Bike’ motorcycle store. The chain should be passed through either the motorcycle frame or rear<br />
wheel and looped through the ground anchor and the two looped ends of the chain should both be secured using the padlock<br />
provided.<br />
286 20 Nov 2011
PART 4: SECTION 5<br />
PHYSICAL SECURITY PROTECTION OF BUILDINGS<br />
Effective security relies on the appropriate combination of physical and electronic measures for the risks faced<br />
and the effective management of those facilities and maintenance of the security solutions and measures<br />
implemented.<br />
To prevent unauthorised entry into a building or area within a building, the components and materials used to<br />
construct that building/area must delay intruders sufficiently to allow an appropriate response.<br />
The effort an intruder needs to exert in order to gain entry is affected by a number of factors which, if<br />
countered by good physical security, will increase the likelihood of deterring potential intruders from even<br />
attempting entry. These factors include:<br />
Preparation and planning - The longer the criminal needs to take to survey a site and develop ways of<br />
overcoming the security measures without detection, the more likely they are to be deterred.<br />
Time spent attempting entry - The more the security delays the intruder when attempting entry, the greater<br />
the risk of them being caught and therefore the more likely they are to be deterred.<br />
Sourcing and transporting tools to overcome the physical security measures in place - The greater the<br />
number/weight of tools the intruder needs to use to overcome the security, and the more specialist the<br />
tools they need, the greater the risk of being caught and the more likely they are to be deterred.<br />
So how do specifiers determine whether physical security measures will be effective at deterring and delaying<br />
unauthorised entry?<br />
LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant<br />
building components, strongpoints, security enclosures and free-standing barriers classifies the resistance to<br />
forced entry provided by security products, systems and building materials.<br />
While previous versions of the standard specified six levels of resistance (security ratings), the latest versions<br />
(Issue 6 and 7) specify eight security ratings. The levels of risk on which the security ratings issued in issue 6<br />
and 7 are based are represented in the following chart.<br />
HIGH RISK<br />
LOW RISK<br />
LPS 1175 SR 8<br />
LPS 1175 SR 7<br />
LPS 1175 SR 6<br />
LPS 1175 SR 5<br />
LPS 1175 SR 4<br />
LPS 1175 SR 3<br />
LPS 1175 SR 2<br />
LPS 1175 SR 1<br />
Products certified to this standard provide 20 minutes of resistance<br />
to extreme means of attempting forced entry into higher value<br />
storage areas.<br />
Products certified to these standards provide 10 minutes of<br />
resistance to professional means of attempting forced entry into<br />
higher value storage areas using a wide range of tools including<br />
mains powered tools.<br />
Products certified to these standards resist experienced attempts at<br />
forced entry using a wide range of tools including battery powered<br />
tools lasting up to 10 minutes (SR 4 and 5) or 5 minutes (SR 3).<br />
Products certified to this standard provide 3 minutes of resistance to<br />
determined attack by an opportunist burglar using a range of<br />
techniques including those that involve creation of noise.<br />
Products certified to this standard provide 1 minute of resistance to<br />
opportunist attempts at entry using a range of techniques including<br />
those that create noise such as those involving breaking glass.<br />
20 Nov 2011 287
PART 4: SECTION 5<br />
PHYSICAL SECURITY PROTECTION OF BUILDINGS<br />
LPS 1175 supports the assessment, approval and specification of security doors, shutters and grilles together<br />
with many other products and systems designed to prevent unauthorised access by mechanical means.<br />
These include:<br />
Cladding Systems Garage Doors Sky Lights<br />
Fences and walls Roofing Systems Strongpoints and Enclosures<br />
Fixed Grilles Temporary Buildings Vehicles<br />
Folding Doorsets Sheds and Tool Stores Windows<br />
LPS 1175 is based on manual attack testing with the resistance provided by the products measured in terms<br />
of the attack tools and time available to the attacker. It enables specifiers to select products according to the<br />
risk.<br />
Further information on the security rating system and attack tools can be found in the standard itself, which<br />
can be downloaded from the Red Book web site www.<strong>RedBookLive</strong>.com.<br />
In addition to certifying windows, doors and shutters to LPS 1175, LPCB also offers approval of these<br />
products to the following standards:<br />
PAS 23-1<br />
PAS 24-1<br />
BS 7950<br />
General performance requirements for door assemblies - Part 1: Single leaf, external<br />
door assemblies to dwellings<br />
Enhanced security performance requirements for door assemblies - Part 1: Single and<br />
double leaf, hinged external door assemblies to dwellings<br />
Specification for enhanced security performance of windows for domestic applications<br />
EN 1627 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance -<br />
Requirements and classification<br />
PAS 23-1, PAS 24-1 and BS 7950 are aimed at domestic applications. Secured by Design report a significant<br />
reduction in domestic burglary where products approved to PAS 24-1 and BS 7950 have been used.<br />
The levels of resistance offered by products approved to PAS 24-1 and BS 7950 is generally lower than that<br />
provided by products approved to LPS 1175, especially if the products incorporate glass or in situations where<br />
the criminal can make sustained amounts of noise while attempting entry.<br />
EN 1627 is the European standard aimed at façade security products used in domestic and commercial<br />
situations.<br />
Specifiers should note that, although the working times specified for grades 2, 3 and 4 in EN 1627 match<br />
those defined for ratings 2, 3 and 4 in LPS 1175 (i.e. 3 minutes, 5 minutes and 10 minutes respectively), LPS<br />
1175 permits a far wider array of tools and attack techniques to be used. Specifiers should therefore not<br />
assume products meeting EN 1627 will offer the ‘same’ levels of resistance when tested to LPS 1175.<br />
In fact, a number of products rated to grade 4 in ENV 1627 tested by BRE to LPS 1175 have failed to achieve<br />
above a Security Rating 2 classification.<br />
Furthermore, because anyone can test products to EN 1627 and the quality of testing can greatly impact on<br />
the ratings attributed to a product, this can affect the resistance to attack actually delivered by products rated<br />
to the standard. LPCB therefore only recognises those tests conducted to this standard by its own<br />
experienced test engineers or by other laboratories that have demonstrated they conduct the tests to suitably<br />
high standards.<br />
Hotel Doorsets<br />
In addition to these standards, LPCB has developed a standard for Hotel Doorsets. LPS 1268 Specification<br />
for the testing and classification of hotel bedroom doorsets covers many aspects of the doorset’s<br />
288 20 Nov 2011
PART 4: SECTION 5<br />
PHYSICAL SECURITY PROTECTION OF BUILDINGS<br />
performance, from security performance through to fire resistance, acoustic and general durability. Copies of<br />
the standard are available free of charge and can be obtained by emailing enquiries@breglobal.com<br />
Product Selection<br />
When selecting a security door, shutter, grille or other façade element, it is important to note aspects such as<br />
the size, locking systems, modes and directions of opening, and the type, size and location of any glazing<br />
incorporated within the product or system. All can affect the level of security provided by the product. These<br />
aspects of each certified product have therefore been described to enable selection of the most appropriate<br />
product for the desired application. Where options, such as glazed in-fills within door leaves, are not covered<br />
in the listing, those options fall outside the scope of that product’s approval.<br />
Unless otherwise stated, the security ratings attributed to the products listed require all lock bolts to be fully<br />
engaged and any deadlocking mechanism provided must be engaged. If a product is shown to achieve more<br />
than one security rating:<br />
The lower rating indicates the security rating achieved by the product when in the “minimum locked<br />
condition”, that is, when the opening element (e.g. door leaf) is closed and only automatic latching<br />
mechanisms are engaged.<br />
The higher rating indicates the security rating achieved by the product when any additional manually<br />
operated deadlocks fitted to the opening element are engaged.<br />
It is important to ensure that the products are installed in accordance with the manufacturer’s instructions and<br />
that all exposed fixings, the substrate into which the device is fitted and the locking mechanisms are regularly<br />
checked to ensure that they are in good condition and that they have not been tampered with. For added<br />
peace of mind, we recommend products are installed by companies certified to LPS 1271 Requirements for<br />
the LPCB Approval and Listing of companies installing fire and security doorsets and shutters, and smoke<br />
barriers for a scope covering the product being specified. A list of currently approved installers is provided in<br />
Volume 2.<br />
20 Nov 2011 289
PART 4: SECTION 5.1<br />
HIGH SECURITY DOORSETS<br />
Doorsets listed in this <strong>section</strong> are approved to LPS 1175 Requirements and testing procedures for the LPCB<br />
approval and listing of intruder resistant building components, strongpoints, security enclosures and freestanding<br />
barriers.<br />
Section 5.1.1 lists high security plain leaf hinged doorsets<br />
Section 5.1.2 lists high security glazed hinged doorsets<br />
Section 5.1.3 lists high security hinged doorsets with other leaf designs, such as those incorporating mesh or<br />
fixed bars.<br />
Section 5.1.4 lists high security folding doorsets<br />
For details of hinged doorsets approved to PAS 23-1 and PAS 24-1 please refer to <strong>section</strong>s 5.2.1 and 5.<strong>2.2</strong><br />
respectively.<br />
290 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
AccentHansen<br />
Greengate Industrial Park, Greengate, Middleton, Manchester M24 1SW, United Kingdom<br />
Tel: +44 (0)161 284 4100 • Fax: +44 (0)161 655 3119<br />
E-mail: info@accenthansen.co.uk • Website: www.servicehansen.com<br />
Certificate No: 021c to LPS 1175: Issue 5<br />
Hinged Security Doorsets<br />
Product<br />
Name<br />
Type<br />
Frame<br />
Dimensions<br />
Height<br />
(m)<br />
Secureshield<br />
4<br />
Single leaf,<br />
outward<br />
opening hinged<br />
security doorset<br />
Double leaf,<br />
outward<br />
opening hinged<br />
security doorset<br />
Double leaf,<br />
outward<br />
opening hinged<br />
security<br />
Single leaf,<br />
outward<br />
opening hinged<br />
security doorset<br />
Frame<br />
Dimensions<br />
Width<br />
(m)<br />
Compatible<br />
Locking<br />
Systems<br />
on Active<br />
Leaf<br />
Compatible<br />
Locking<br />
Systems<br />
on Passive<br />
Leaf<br />
Locked<br />
Condition<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
2.090 1.275 3 N/A Minimum 3 021c/01<br />
2.090 1.775 3 4, 5 or 6 Minimum 3<br />
2.090 1.775 1, 2 or 3 4, 5 or 6 Optimum 4<br />
2.090 1.275 1, 2 or 3 N/A Optimum 4<br />
Compatible Locking Systems<br />
20 Nov 2011 291
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Compatible<br />
Locking<br />
System<br />
Locking System Type Locked Compatible operating devices<br />
Condition External Face Internal Face<br />
1 Assa Mico 942-3 MSD 1 Three point panic<br />
exit device fitted<br />
w ith MSD<br />
deadlocking device<br />
2 Assa Mico 942-3P MSD 1 Three point<br />
emergency exit<br />
device operated by<br />
a push pad and<br />
fitted w ith the MSD<br />
deadlocking device<br />
3 Assa Mico 942-3L MSD 1 Three point<br />
emergency exit<br />
device operated by<br />
a lever handle and<br />
fitted w ith the MSD<br />
deadlocking device<br />
4 Assa Mico 942 Tw o point panic exit<br />
device<br />
5 Assa Mico 942P Tw o point<br />
emergency exit<br />
device operated by<br />
a push pad<br />
6 Assa Mico 942L Tw o point<br />
emergency exit<br />
device operated by<br />
a lever handle<br />
Optimum 2 None Key and panic<br />
bar<br />
Optimum 2 None Key and push<br />
pad<br />
Optimum 2<br />
Minimum<br />
None<br />
None<br />
None<br />
None<br />
Key and lever<br />
handle<br />
Lever handle<br />
Panic bar<br />
Push pad<br />
Lever handle<br />
Notes:<br />
1. The MSD (Micro Switched Deadlock) system is operated by key from inside. This must be deadlocked in order to achieve the level of<br />
security relating to the optimum locked condition.<br />
2. Although outside the scope of LPS1175: Issue 5, special consideration should be paid to the deadlocking of the Assa Mico panic and<br />
emergency three point locking system. This is because it is generally not acceptable to separately deadlock a doorset that is fitted<br />
with a panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or emergency device,<br />
since doing so can inhibit means of escape. For further information, reference should be made to the appropriate standards for<br />
emergency exit and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively.<br />
Certificate No: 021d to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product<br />
Name<br />
Doorset<br />
Configuration<br />
Minimum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
SecureShield<br />
2<br />
Single leaf<br />
outward<br />
opening<br />
hinged security<br />
doorset<br />
Single leaf<br />
outward<br />
opening<br />
hinged security<br />
doorset<br />
Single leaf<br />
outward<br />
opening<br />
hinged security<br />
doorset<br />
Maximum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
1.5 Refer to<br />
compatible<br />
locking<br />
systems<br />
1.5 Refer to<br />
compatible<br />
locking<br />
systems<br />
1.5 Refer to<br />
compatible<br />
locking<br />
systems<br />
Minimum<br />
Structural<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width<br />
(m)<br />
Locking<br />
System<br />
Active<br />
Leaf<br />
Locking<br />
Sysetm<br />
Passive<br />
Leaf<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.5 1.25 1 - 2 021d/01<br />
0.5 1.25 2 - 2<br />
0.5 1.25 3 - 2<br />
292 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Product<br />
Name<br />
Doorset<br />
Configuration<br />
Single leaf<br />
outward<br />
opening<br />
hinged security<br />
doorset<br />
Double leaf<br />
outward<br />
opening<br />
hinged security<br />
doorset<br />
Double leaf<br />
outward<br />
opening<br />
hinged security<br />
doorset<br />
Double leaf<br />
outward<br />
opening<br />
hinged security<br />
doorset<br />
Double leaf<br />
outward<br />
opening<br />
hinged security<br />
doorset<br />
Minimum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
1.5 Refer to<br />
compatible<br />
locking<br />
systems<br />
1.5 Refer to<br />
compatible<br />
locking<br />
systems<br />
1.5 Refer to<br />
compatible<br />
locking<br />
systems<br />
1.5 Refer to<br />
compatible<br />
locking<br />
systems<br />
1.5 Refer to<br />
compatible<br />
locking<br />
systems<br />
Minimum<br />
Structural<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width<br />
(m)<br />
Locking<br />
System<br />
Active<br />
Leaf<br />
Locking<br />
Sysetm<br />
Passive<br />
Leaf<br />
Security<br />
Rating<br />
0.5 1.25 6 - 2<br />
Cert.<br />
No.<br />
1.3 2.5 1 4 2 021d/02<br />
1.3 2.5 2 4 2<br />
1.3 2.5 5 5 2<br />
1.3 2.5 7 7 2<br />
Compatible Locking Systems<br />
Compatible<br />
Locking<br />
System<br />
Manufacturer Model Description Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
1 Associated<br />
Finishers Limited<br />
2 Associated<br />
Finishers Limited<br />
3 Fred Duncombe<br />
Limited<br />
Compatible<br />
Cylinders<br />
QFSL Sashlock 2.4 A<br />
QFDL Deadlock 2.4 A<br />
Exidor<br />
702B/30S w ith<br />
710EC<br />
Tw o point panic bar locking<br />
system w ith external access<br />
device<br />
2.45 B<br />
4 Fred Duncombe<br />
Limited<br />
Exidor HS923 Tow er bolts 2.4 -<br />
5 Fred Duncombe<br />
Limited<br />
Exidor<br />
701BD/30S<br />
w ith 710EC<br />
Double door panic bar locking<br />
system (single point anti-thrust<br />
panic exit locking system w ith<br />
external access device on active<br />
leaf and a tw o point panic exit<br />
locking system on passive leaf)<br />
2.4 B<br />
6 Fred Duncombe<br />
Limited<br />
7 Fred Duncombe<br />
Limited<br />
Exidor<br />
702B/30S<br />
Exidor<br />
701BD/30S<br />
Tw o point panic bar locking<br />
system w ith no external entry<br />
Double door panic bar locking<br />
system w ith no external entry<br />
(single point anti-thrust panic exit<br />
locking system and a tw o point<br />
panic exit locking system on<br />
passive leaf)<br />
2.45 -<br />
2.4 -<br />
Compatible Cylinders<br />
20 Nov 2011 293
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Cylinder Manufacturer Model Type<br />
Reference<br />
A Assa R527 Double europrofile cylinder (key:thumbturn)<br />
B Zone 1500 Single europrofile cylinder<br />
Ascot Doors Limited<br />
Britannia Way Industrial Park, Union Road, Bolton BL2 2HE, United Kingdom<br />
Tel: +44 (0)1204 545801 • Fax: +44 (0)1204 545800<br />
E-mail: sales@ascotdoors.co.uk • Website: www.ascotdoors.co.uk<br />
Certificate No: 131d to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product Name Doorset<br />
Configuration<br />
Centurion A355<br />
Centurion A364S<br />
Centurion A364D<br />
Centurion A363S<br />
Centurion A363D<br />
Single leaf,<br />
outward<br />
opening hinged<br />
doorset<br />
Single leaf,<br />
outward<br />
opening hinged<br />
doorset<br />
Double leaf,<br />
outward<br />
opening hinged<br />
doorset<br />
Single leaf,<br />
outward<br />
opening hinged<br />
doorset<br />
Double leaf,<br />
outward<br />
opening hinged<br />
doorset<br />
Minimum<br />
Clear<br />
Opening<br />
Height (m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width (m)<br />
Maximum<br />
Clear<br />
Opening<br />
Height (m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width (m)<br />
Security<br />
Rating 1<br />
Cert. No.<br />
1.8 0.7 2.5 1.35 4 131d/01<br />
1.8 0.7 2.9 1.35 4 131d/02<br />
1.8 1.4 2.9 2.61 4 131d/03<br />
1.8 0.7 2.9 1.35 3 131d/04<br />
1.8 1.4 2.9 2.61 3 131d/05<br />
Compatible Locking Configurations<br />
294 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Product Name<br />
Centurion A355S<br />
Doorset<br />
Configuration<br />
Compatible Locking Systems<br />
Active Leaf<br />
Passive Leaf<br />
Single leaf, outw ard<br />
19 N/A<br />
security doorset 2<br />
opening hinged<br />
Centurion A363S<br />
Centurion A363D<br />
Centurion A364S<br />
Centurion A364D<br />
Single leaf, outw ard 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15,<br />
opening hinged 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,<br />
security doorset 2 26, 27, 28, 29, 30, 31, 32, 33, 34 and<br />
35<br />
Double leaf, outw ard 4, 5, 6, 7, 8, 9, 10 ,11, 12, 13, 14, 15,<br />
opening hinged 16, 17, 18, 19, 20, 21, 22, 23, 24, 25,<br />
security doorset 2,3 26, 27, 28, 29, 30, 31, 32, 33, 34 and<br />
35<br />
Single leaf, outw ard 5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25,<br />
opening hinged 27, 29, 36, 37, 38, 39, 40, 41, 42, 43,<br />
security doorset 2 44, 45, 46, 47, 48, 49, 50, 51, 52, 53<br />
and 54<br />
Double leaf, outw ard 5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25,<br />
opening hinged 27, 29, 36, 37, 38, 39, 40, 41, 42, 43,<br />
security doorset 2,3 44, 45, 46, 47, 48, 49, 50, 51, 52, 53<br />
and 54<br />
N/A<br />
1, 2, 3<br />
N/A<br />
1, 2, 3<br />
Compatible Locking Systems<br />
Compatible<br />
Locking<br />
Systems<br />
Manufacturer Model Type Compatible Operating Devices<br />
1 Tindall<br />
Engineering Ltd<br />
Mico 942<br />
2-w ay panic exit<br />
device<br />
External Face<br />
Internal Face<br />
Compatible<br />
Cylinders 4<br />
None Panic bar -<br />
2 Tindall<br />
Engineering Ltd<br />
Mico 942P<br />
2-w ay emergency<br />
exit device<br />
None Push pad -<br />
3 Tindall<br />
Engineering Ltd<br />
Mico 942L<br />
2-w ay emergency<br />
exit device<br />
None Lever handle -<br />
4 Tindall<br />
Engineering Ltd<br />
Mico 942-3 / ELK<br />
3<br />
3-w ay panic exit<br />
device<br />
Key (via ELK3) Panic bar A<br />
5 Tindall<br />
Engineering Ltd<br />
Mico 942-3<br />
3-w ay panic exit<br />
device<br />
None Panic bar -<br />
20 Nov 2011 295
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
6 Tindall<br />
Engineering Ltd<br />
Mico 942-3P /<br />
ELK 3<br />
3-w ay emergency<br />
exit device<br />
Key (via ELK3) Push pad A<br />
7 Tindall<br />
Engineering Ltd<br />
Mico 942-3P<br />
3-w ay emergency<br />
exit device<br />
None Push pad -<br />
8 Tindall<br />
Engineering Ltd<br />
Mico 942-3L /<br />
ELK 3<br />
3-w ay emergency<br />
exit device<br />
Key (via ELK3) Lever handle A<br />
9 Tindall<br />
Engineering Ltd<br />
Mico 942-3L<br />
3-w ay emergency<br />
exit device<br />
None Lever handle -<br />
10 Tindall<br />
Engineering Ltd<br />
Mico 942-3 EM<br />
SEC / HSCH 3<br />
3-w ay locking External access<br />
system w ith solenoid control device 6 or<br />
deadlock and electromechanical<br />
access HSCH3 cylinder<br />
key override w ith<br />
control pow ered by guard and lever<br />
12 V 5 handle<br />
Internal access<br />
control device or<br />
thumbturn<br />
override and ‘full<br />
w idth’ push plate<br />
B<br />
11 Tindall<br />
Engineering Ltd<br />
Mico 942-3 EM<br />
SEC<br />
3-w ay locking External access<br />
system w ith solenoid control device 6<br />
deadlock and electromechanical<br />
access<br />
and lever handle<br />
control pow ered by<br />
12 V 5<br />
Internal access<br />
control device or<br />
thumbturn<br />
override and ‘full<br />
w idth’ push plate<br />
-<br />
12 Tindall<br />
Engineering Ltd<br />
Mico 942-3P EM<br />
SEC / HSCH 3<br />
3-w ay locking External access<br />
system w ith solenoid control device 6 or<br />
deadlock and electromechanical<br />
access HSCH3 cylinder<br />
key override w ith<br />
control pow ered by guard and lever<br />
12 V 5 handle<br />
Internal access<br />
control device or<br />
thumbturn<br />
override and push<br />
pad<br />
B<br />
13 Tindall<br />
Engineering Ltd<br />
Mico 942-3P EM<br />
SEC<br />
3-w ay locking External access<br />
system w ith solenoid control device 6<br />
deadlock and electromechanical<br />
access<br />
and lever handle<br />
control pow ered by<br />
12 V 5<br />
Internal access<br />
control device or<br />
thumbturn<br />
override and push<br />
pad<br />
-<br />
14 Tindall<br />
Engineering Ltd<br />
Mico 942-3L EM<br />
SEC / HSCH 3<br />
3-w ay locking External access<br />
system w ith solenoid control device 6 or<br />
deadlock and electromechanical<br />
access HSCH3 cylinder<br />
key override w ith<br />
control pow ered by guard and lever<br />
12 V 5 handle<br />
Internal access<br />
control device or<br />
thumbturn<br />
override and lever<br />
handle<br />
B<br />
15 Tindall<br />
Engineering Ltd<br />
Mico 942-3L EM<br />
SEC<br />
3-w ay locking External access<br />
system w ith solenoid control device 6<br />
deadlock and electromechanical<br />
access<br />
and lever handle<br />
control pow ered by<br />
12 V 5<br />
Internal access<br />
control device or<br />
thumbturn<br />
override and lever<br />
handle<br />
-<br />
296 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
16 Tindall<br />
Engineering Ltd<br />
Mico 942-3L INT<br />
AD / HSCH 3<br />
3-w ay locking<br />
system w ith<br />
automatic deadlock<br />
HSCH3 cylinder<br />
guard and lever<br />
handle<br />
Thumbturn and<br />
lever handle<br />
B<br />
17 Tindall<br />
Engineering Ltd<br />
Mico 942-3L INT<br />
AD<br />
3-w ay locking<br />
system w ith<br />
automatic deadlock<br />
None<br />
Thumb turn and<br />
lever handle<br />
-<br />
18 Tindall<br />
Engineering Ltd<br />
Mico 942-3 INT<br />
MD / HSCH 3<br />
3-w ay locking<br />
system w ith manual<br />
deadlock<br />
HSCH3 cylinder<br />
guard and lever<br />
handle<br />
Key or thumbturn<br />
and full w idth<br />
push plate<br />
B<br />
19 Tindall<br />
Engineering Ltd<br />
Mico 942-3 INT<br />
MD<br />
3-w ay locking<br />
system w ith manual<br />
deadlock<br />
None<br />
Key or thumbturn<br />
and full w idth<br />
push plate<br />
-<br />
20 Tindall<br />
Engineering Ltd<br />
Mico 942-3P INT<br />
MD / HSCH 3<br />
3-w ay locking<br />
system w ith manual<br />
deadlock<br />
HSCH3 cylinder<br />
guard and lever<br />
handle<br />
Key or thumbturn<br />
and push pad<br />
B<br />
21 Tindall<br />
Engineering Ltd<br />
Mico 942-3P INT<br />
MD<br />
3-w ay locking<br />
system w ith manual<br />
deadlock<br />
None<br />
Key or thumbturn<br />
and push pad<br />
-<br />
22 Tindall<br />
Engineering Ltd<br />
Mico 942-3L INT<br />
MD / HSCH 3<br />
3-w ay locking<br />
system w ith manual<br />
deadlock<br />
HSCH3 cylinder<br />
guard and lever<br />
handle<br />
Key or thumbturn<br />
and lever handle<br />
B<br />
23 Tindall<br />
Engineering Ltd<br />
Mico 942-3L INT<br />
MD<br />
3-w ay locking<br />
system w ith manual<br />
deadlock<br />
None<br />
Key or thumbturn<br />
and lever handle<br />
-<br />
24 Tindall<br />
Engineering Ltd<br />
Mico 942-3<br />
SATE EM SEC /<br />
HSCH 3<br />
3-w ay panic exit External access<br />
device w ith solenoid control device 6 or<br />
deadlock and electro key override w ith<br />
mechanical access HSCH3 cylinder<br />
control pow ered by guard and lever<br />
12 V 5 handle<br />
Panic bar<br />
B<br />
25 Tindall<br />
Engineering Ltd<br />
Mico 942-3 SATE<br />
EM SEC<br />
3-w ay panic exit External access<br />
device w ith solenoid control device 6<br />
deadlock and electro and lever handle<br />
mechanical access<br />
control pow ered by<br />
12 V 5<br />
Panic bar -<br />
20 Nov 2011 297
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
26 Tindall<br />
Engineering Ltd<br />
Mico 942-3P<br />
SATE EM SEC /<br />
HSCH 3<br />
3-w ay emergency External access<br />
exit device w ith control device 6 or<br />
solenoid deadlock key override w ith<br />
and electro HSCH3 cylinder<br />
mechanical access guard and lever<br />
control pow ered by handle<br />
12 V 5<br />
Push pad<br />
B<br />
27 Tindall<br />
Engineering Ltd<br />
Mico 942-3P<br />
SATE EM SEC<br />
3-w ay emergency External access<br />
exit device w ith control device 6<br />
solenoid deadlock and lever handle<br />
and electro<br />
mechanical access<br />
control pow ered by<br />
12 V 5<br />
Push pad -<br />
28 Tindall<br />
Engineering Ltd<br />
Mico 942-3L<br />
SATE EM SEC /<br />
HSCH 3<br />
3-w ay emergency External access<br />
exit device w ith control device 6 or<br />
solenoid deadlock key override w ith<br />
and electro HSCH3 cylinder<br />
mechanical access guard and lever<br />
control pow ered by handle<br />
12 V 5<br />
Lever handle<br />
B<br />
29 Tindall<br />
Engineering Ltd<br />
Mico 942-3L<br />
SATE EM SEC<br />
3-w ay emergency External access<br />
exit device w ith control device 6<br />
solenoid deadlock and lever handle<br />
and electro<br />
mechanical access<br />
control pow ered by<br />
12 V 5<br />
Lever handle -<br />
30 Tindall<br />
Engineering Ltd<br />
Mico 942-3 SATE<br />
AD / HSCH 3<br />
3-w ay panic exit<br />
device w ith<br />
automatic deadlock<br />
Key via HSCH3<br />
cylinder guard<br />
and lever handle<br />
Panic bar<br />
B<br />
31 Tindall<br />
Engineering Ltd<br />
Mico 942-3P 3-w ay emergency<br />
SATE AD / HSCH exit device w ith<br />
3<br />
automatic deadlock<br />
Key via HSCH3<br />
cylinder guard<br />
and lever handle<br />
Push pad<br />
B<br />
32 Tindall<br />
Engineering Ltd<br />
Mico 942-3L 3-w ay emergency<br />
SATE AD / HSCH exit device w ith<br />
3<br />
automatic deadlock<br />
Key via HSCH3<br />
cylinder guard<br />
and lever handle<br />
Lever handle<br />
B<br />
33 Tindall<br />
Engineering Ltd<br />
Mico 942-3 SATE<br />
MD / HSCH 3<br />
3-w ay panic exit<br />
device w ith manual<br />
deadlock<br />
Key via HSCH3<br />
cylinder guard<br />
and lever handle<br />
Panic bar<br />
B<br />
34 Tindall<br />
Engineering Ltd<br />
Mico 942-3P 3-w ay emergency<br />
SATE MD / HSCH exit device w ith<br />
3<br />
manual deadlock<br />
Key via HSCH3<br />
cylinder guard<br />
and lever handle<br />
Push pad<br />
B<br />
35 Tindall<br />
Engineering Ltd<br />
Mico 942-3L 3-w ay emergency<br />
SATE MD / HSCH exit device w ith<br />
3<br />
manual deadlock<br />
Key via HSCH3<br />
cylinder guard<br />
and lever handle<br />
Lever handle<br />
B<br />
298 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
36 Tindall<br />
Engineering Ltd<br />
Mico 942-3 / ELK<br />
4<br />
3-w ay panic exit<br />
device<br />
Key (via ELK4) Panic bar A<br />
37 Tindall<br />
Engineering Ltd<br />
Mico 942-3P /<br />
ELK 4<br />
3-w ay emergency<br />
exit device<br />
Key (via ELK4) Push pad A<br />
38 Tindall<br />
Engineering Ltd<br />
Mico 942-3L /<br />
ELK 4<br />
3-w ay emergency<br />
exit device<br />
Key (via ELK4) Lever handle A<br />
39 Tindall<br />
Engineering Ltd<br />
Mico 942-3 EM<br />
SEC / HSCH 4<br />
3-w ay locking External access<br />
system w ith solenoid control device 6 or<br />
deadlock and electromechanical<br />
access HSCH4 cylinder<br />
key override w ith<br />
control pow ered by guard and lever<br />
12 V 5 handle<br />
Internal access<br />
control device or<br />
thumbturn<br />
override and ‘full<br />
w idth’ push plate<br />
B<br />
40 Tindall<br />
Engineering Ltd<br />
Mico 942-3P EM<br />
SEC / HSCH 4<br />
3-w ay locking External access<br />
system w ith solenoid control device 6 or<br />
deadlock and electromechanical<br />
access HSCH4 cylinder<br />
key override w ith<br />
control pow ered by guard and lever<br />
12 V 5 handle<br />
Internal access<br />
control device or<br />
thumbturn<br />
override and push<br />
pad<br />
B<br />
41 Tindall<br />
Engineering Ltd<br />
Mico 942-3L EM<br />
SEC / HSCH 4<br />
3-w ay locking External access<br />
system w ith solenoid control device 6 or<br />
deadlock and electromechanical<br />
access HSCH4 cylinder<br />
key override w ith<br />
control pow ered by guard and lever<br />
12 V 5 handle<br />
Internal access<br />
control device or<br />
thumbturn<br />
override and lever<br />
handle<br />
B<br />
42 Tindall<br />
Engineering Ltd<br />
Mico 942-3L INT<br />
AD / HSCH 4<br />
3-w ay locking<br />
system w ith<br />
automatic deadlock<br />
HSCH4 cylinder<br />
guard and lever<br />
handle<br />
Thumbturn and<br />
lever handle<br />
B<br />
43 Tindall<br />
Engineering Ltd<br />
Mico 942-3 INT<br />
MD / HSCH 4<br />
3-w ay locking<br />
system w ith manual<br />
deadlock<br />
HSCH4 cylinder<br />
guard and lever<br />
handle<br />
Key or thumbturn<br />
and full w idth<br />
push plate<br />
B<br />
44 Tindall<br />
Engineering Ltd<br />
Mico 942-3P INT<br />
MD / HSCH 4<br />
3-w ay locking<br />
system w ith manual<br />
deadlock<br />
HSCH4 cylinder<br />
guard and lever<br />
handle<br />
Key or thumbturn<br />
and push pad<br />
B<br />
45 Tindall<br />
Engineering Ltd<br />
Mico 942-3L INT<br />
MD / HSCH 4<br />
3-w ay locking<br />
system w ith manual<br />
deadlock<br />
HSCH4 cylinder<br />
guard and lever<br />
handle<br />
Key or thumbturn<br />
and lever handle<br />
B<br />
20 Nov 2011 299
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
46 Tindall<br />
Engineering Ltd<br />
Mico 942-3<br />
SATE EM SEC /<br />
HSCH 4<br />
3-w ay panic exit External access<br />
device w ith solenoid control device 6 or<br />
deadlock and electro key override w ith<br />
mechanical access HSCH4 cylinder<br />
control pow ered by guard and lever<br />
12 V 5 handle<br />
Panic bar<br />
B<br />
47 Tindall<br />
Engineering Ltd<br />
Mico 942-3P<br />
SATE EM SEC /<br />
HSCH 4<br />
3-w ay emergency External access<br />
exit device w ith control device 6 or<br />
solenoid deadlock key override w ith<br />
and electro HSCH4 cylinder<br />
mechanical access guard and lever<br />
control pow ered by handle<br />
12 V 5<br />
Push pad<br />
B<br />
48 Tindall<br />
Engineering Ltd<br />
Mico 942-3L<br />
SATE EM SEC /<br />
HSCH 4<br />
3-w ay emergency External access<br />
exit device w ith control device 6 or<br />
solenoid deadlock key override w ith<br />
and electro HSCH4 cylinder<br />
mechanical access guard and lever<br />
control pow ered by handle<br />
12 V 5<br />
Lever handle<br />
B<br />
49 Tindall<br />
Engineering Ltd<br />
Mico 942-3 SATE<br />
AD / HSCH 4<br />
3-w ay panic exit<br />
device w ith<br />
automatic deadlock<br />
Key via HSCH4<br />
cylinder guard<br />
and lever handle<br />
Panic bar<br />
B<br />
50 Tindall<br />
Engineering Ltd<br />
Mico 942-3P 3-w ay emergency<br />
SATE AD / HSCH exit device w ith<br />
4<br />
automatic deadlock<br />
Key via HSCH4<br />
cylinder guard<br />
and lever handle<br />
Push pad<br />
B<br />
51 Tindall<br />
Engineering Ltd<br />
Mico 942-3L 3-w ay emergency<br />
SATE AD / HSCH exit device w ith<br />
4<br />
automatic deadlock<br />
Key via HSCH4<br />
cylinder guard<br />
and lever handle<br />
Lever handle<br />
B<br />
52 Tindall<br />
Engineering Ltd<br />
Mico 942-3 SATE<br />
MD / HSCH 4<br />
3-w ay panic exit<br />
device w ith manual<br />
deadlock<br />
Key via HSCH4<br />
cylinder guard<br />
and lever handle<br />
Panic bar<br />
B<br />
53 Tindall<br />
Engineering Ltd<br />
Mico 942-3P 3-w ay emergency<br />
SATE MD / HSCH exit device w ith<br />
4<br />
manual deadlock<br />
Key via HSCH4<br />
cylinder guard<br />
and lever handle<br />
Push pad<br />
B<br />
54 Tindall<br />
Engineering Ltd<br />
Mico 942-3L 3-w ay emergency<br />
SATE MD / HSCH exit device w ith<br />
4<br />
manual deadlock<br />
Key via HSCH4<br />
cylinder guard<br />
and lever handle<br />
Lever handle<br />
B<br />
Compatible Cylinders<br />
Cylinder Manufacturer Model Type<br />
Reference<br />
A Assa 4801 Half oval mechanical cylinder<br />
B Assa 4807 Half oval mechanical cylinder<br />
Notes:<br />
1. These ratings apply to doorsets with locking fully engaged, i.e. in optimum locked condition. The doorsets achieve Security Rating 2<br />
when the following locking systems are fitted and left in the minimum locked condition, e.g. internal manual deadlock not engaged:<br />
18, 19, 20, 21, 22, 23, 43, 44 and 45.<br />
2. Although outside the scope of LPS 1175: Issue 6, special consideration should be paid to the use of locking systems with separate<br />
deadlocks, e.g. Mico 942-3 INT MD. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a<br />
300 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or emergency device. For<br />
further information, please refer to the appropriate standards for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125<br />
respectively.<br />
3. Although outside the scope of LPS 1175: Issue 6, special consideration should be paid to the use of single operating panic or<br />
emergency exit devices. This is because it is generally accepted that when two panic or emergency exit devices are fitted to double<br />
doorsets the operation of either device should disengage simultaneously such that both leafs can open. For further information,<br />
please refer to the appropriate standard for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively.<br />
4. This is applicable to the external cylinders only. Due to the resistance afforded by the doorset there is no restrictions on the type of<br />
internal cylinder used.<br />
5. Fail secure version only.<br />
6. The resistance of the access control locks to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175.<br />
Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any<br />
access control equipment that may be used to operate these locking systems. This is because the scope of access control devices<br />
and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that Ascot Doors<br />
Limited satisfy themselves that the components are either resistant to mechanical and other forms of tampering/abuse, or that they<br />
are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the<br />
locking system to disengage.<br />
Bradbury Security<br />
Dunlop Way, Queensway Industrial Estate, Scunthorpe DN16 3RN, United Kingdom<br />
Tel: +44 (0)1724 271999 • Fax: +44 (0)1724 271888<br />
E-mail: sales@bradburyuk.com • Website: www.bradburyuk.com<br />
Certificate No: 312c to LPS 1175: Issue 5<br />
Hinged Security Doorsets<br />
Product<br />
Type<br />
Name<br />
Fortress 2<br />
Single leaf outward opening security<br />
louvered door<br />
Minimum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.5 0.5 2.3 1.0 2 312c/01<br />
Compatible Locking Devices<br />
Lock Type Approved product (LPCB Ref. No. 312c/01)<br />
Siver 921 Three-point locking system <br />
Certificate No: 312d to LPS 1175: Issue 6<br />
Hinged Doorsets<br />
Product<br />
Name<br />
M2M 1<br />
Type<br />
Single leaf outward<br />
opening hinged security<br />
doorset<br />
Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Compataible<br />
Locking<br />
Systems<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1745 2475 740 1210 1, 2, 4 and 5 1 312d/01<br />
1745 2410 740 990 3 1<br />
Compataible Locking Systems<br />
20 Nov 2011 301
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Option Manufacturer Type Operating Devices<br />
1 Union JL2C21R sash<br />
lock<br />
External Face<br />
Key and lever<br />
handle<br />
Internal face<br />
Key and lever<br />
handle<br />
Compatible<br />
Cylinders<br />
Baton double<br />
europrofile<br />
cylinder (key:key)<br />
2 Union JL2C22R dead<br />
lock<br />
Key and fixed<br />
pull handle<br />
Key and fixed pull<br />
handle<br />
Baton double<br />
europrofile<br />
cylinder (key:key)<br />
3 Yale Yale 82<br />
deadbolt<br />
4 IDC IDC 736 2 point<br />
panic exit<br />
system<br />
Key and fixed<br />
pull handle<br />
5 Hooply Combat Key and lever<br />
multipoint handle<br />
locking system<br />
Turn handle<br />
None Panic bar None<br />
Thumbturn and<br />
lever handle<br />
Yale 82 rim<br />
cylinder<br />
Combat 65 mm<br />
europrofile double<br />
cylinder<br />
(key:thumbturn)<br />
Certificate No: 312e to LPS 1175: Issue 7<br />
Hinged Security Doorsets<br />
Product<br />
Name<br />
Product Type Minimum<br />
Structural<br />
Opening Height<br />
(m)<br />
M2M3 Single leaf<br />
outward<br />
opening<br />
Maximum<br />
Structural<br />
Opening Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.745 2.43 0.74 1.18 3 1, 2, 3 312e/01<br />
doorset<br />
Double leaf 1.745 2.43 1.15 <strong>2.2</strong>0 3<br />
doorset 4<br />
outward<br />
opening<br />
1, 2, 3<br />
Approved Locking Configurations<br />
LPCB<br />
Ref. No.<br />
Product<br />
Name<br />
312e/01 M2M3<br />
Type<br />
Compatible Locking Devices<br />
Active Leaf<br />
Passive Leaf<br />
Single leaf outw ard opening plain leafed doorset 5 1, 3 to 182 N/A<br />
Single leaf outw ard opening louvred doorset 2 N/A<br />
Double leaf outw ard opening plain leafed doorset 5, 6, 7 1, 3 to 182 62, 64, 66, 76, 78, 103,<br />
105, 107, 109, 183 or 184<br />
Double leaf outw ard opening louvred doorset 2 183 or 184<br />
Compatible Locking Devices 8<br />
302 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Compatible Manufacturer Model Type Com patible Operating Device Compatible<br />
Locking<br />
Cylinders<br />
System<br />
External Face Internal Face<br />
1 Hooply Combat Multi-point locking Key and lever handle Key and lever handle AB<br />
system<br />
2 Bradbury<br />
Security<br />
- 4-w ay locking<br />
mechanism<br />
Key and lever handle Latch mechanism<br />
and lever handle<br />
AW, AX, AY and<br />
AZ<br />
3 Tindall<br />
Engineering<br />
Limited<br />
Abryll PE2<br />
/ELK3<br />
Single point panic<br />
exit device<br />
Key and lever handle Panic bar A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q and R<br />
4 Tindall<br />
Engineering<br />
Limited<br />
5 Tindall<br />
Engineering<br />
Limited<br />
6 Tindall<br />
Engineering<br />
Limited<br />
7 Tindall<br />
Engineering<br />
Limited<br />
8 Tindall<br />
Engineering<br />
Limited<br />
9 Tindall<br />
Engineering<br />
Limited<br />
Abryll PE2<br />
Abryll PE1<br />
/ELK3<br />
Abryll PE1<br />
Abryll PE3<br />
/ELK3<br />
Abryll PE3<br />
Abryll EM2<br />
/USCH3<br />
Single point panic<br />
exit device<br />
Single point<br />
emergency exit<br />
device<br />
Single point<br />
emergency exit<br />
device<br />
Single point<br />
emergency exit<br />
device<br />
Single point<br />
emergency exit<br />
device<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
None Panic bar -<br />
Key and lever handle Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q and R<br />
None Push pad -<br />
Key and lever handle Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q and R<br />
None Lever handle -<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
10 Tindall<br />
Engineering<br />
Limited<br />
Abryll EM2<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
-<br />
11 Tindall<br />
Engineering<br />
Limited<br />
Abryll EM1<br />
/USCH3<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
12 Tindall<br />
Engineering<br />
Limited<br />
Abryll EM1<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
-<br />
20 Nov 2011 303
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
13 Tindall<br />
Engineering<br />
Limited<br />
Abryll EM3<br />
/USCH3<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
14 Tindall<br />
Engineering<br />
Limited<br />
Abryll EM3<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
-<br />
15 Tindall<br />
Engineering<br />
Limited<br />
16 Tindall<br />
Engineering<br />
Limited<br />
17 Tindall<br />
Engineering<br />
Limited<br />
18 Tindall<br />
Engineering<br />
Limited<br />
19 Tindall<br />
Engineering<br />
Limited<br />
20 Tindall<br />
Engineering<br />
Limited<br />
21 Tindall<br />
Engineering<br />
Limited<br />
22 Tindall<br />
Engineering<br />
Limited<br />
23 Tindall<br />
Engineering<br />
Limited<br />
24 Tindall<br />
Engineering<br />
Limited<br />
Abryll AD3<br />
/USCH3<br />
Abryll AD3<br />
Abryll MD2<br />
/USCH3<br />
Abryll MD2<br />
Abryll MD1<br />
/USCH3<br />
Abryll MD1<br />
Abryll MD3<br />
/USCH3<br />
Abryll MD3<br />
Abryll SATE<br />
EM2 /USCH3<br />
Abryll SATE<br />
EM2<br />
Single point locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
Single point locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point panic<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Single point panic<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Key or thumbturn<br />
and lever handle<br />
Key or thumbturn<br />
and lever handle<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push pad<br />
Key or thumb turn<br />
and push pad<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and lever handle<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
Panic bar A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Panic bar -<br />
304 20 Nov 2011
25 Tindall<br />
Engineering<br />
Limited<br />
26 Tindall<br />
Engineering<br />
Limited<br />
27 Tindall<br />
Engineering<br />
Limited<br />
28 Tindall<br />
Engineering<br />
Limited<br />
29 Tindall<br />
Engineering<br />
Limited<br />
30 Tindall<br />
Engineering<br />
Limited<br />
31 Tindall<br />
Engineering<br />
Limited<br />
32 Tindall<br />
Engineering<br />
Limited<br />
33 Tindall<br />
Engineering<br />
Limited<br />
34 Tindall<br />
Engineering<br />
Limited<br />
Abryll SATE<br />
EM1 /USCH3<br />
Abryll SATE<br />
EM1<br />
Abryll SATE<br />
EM3 /USCH3<br />
Abryll SATE<br />
EM3<br />
Abryll SATE<br />
AD2/USCH3<br />
Abryll SATE<br />
AD1/USCH3<br />
Abryll SATE<br />
AD3/USCH3<br />
Abryll SATE<br />
MD2/USCH3<br />
Abryll SATE<br />
MD1/USCH3<br />
Abryll SATE<br />
MD3/USCH3<br />
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Single point<br />
emergency exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point<br />
emergency exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point<br />
emergency exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point<br />
emergency exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point panic<br />
exit device w ith<br />
automatic<br />
deadlocking<br />
Single point<br />
emergency exit<br />
device w ith<br />
automatic<br />
deadlocking<br />
Single point<br />
emergency exit<br />
device w ith<br />
automatic<br />
deadlocking<br />
Single point panic<br />
exit device w ith<br />
manual deadlocking<br />
Single point<br />
emergency exit<br />
device w ith manual<br />
deadlocking<br />
Single point<br />
emergency exit<br />
device w ith manual<br />
deadlocking<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Push pad -<br />
Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Lever handle -<br />
Key and lever handle Panic bar A, B, C, D, E, F,<br />
G, H, I, J, K, L, M,<br />
N, O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Lever handle A, B, C, D, E, F,<br />
G, H, I, J, K, L, M,<br />
N, O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Panic bar A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
20 Nov 2011 305
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
35 Tindall<br />
Engineering<br />
Limited<br />
36 Tindall<br />
Engineering<br />
Limited<br />
37 Tindall<br />
Engineering<br />
Limited<br />
38 Tindall<br />
Engineering<br />
Limited<br />
39 Tindall<br />
Engineering<br />
Limited<br />
40 Tindall<br />
Engineering<br />
Limited<br />
41 Tindall<br />
Engineering<br />
Limited<br />
42 Tindall<br />
Engineering<br />
Limited<br />
43 Tindall<br />
Engineering<br />
Limited<br />
44 Tindall<br />
Engineering<br />
Limited<br />
45 Tindall<br />
Engineering<br />
Limited<br />
Abryll PE2 /<br />
EURO<br />
ELK 3<br />
Abryll<br />
PE1/EURO<br />
ELK3<br />
Abryll<br />
PE3/EURO<br />
ELK3<br />
Abryll EPC<br />
EM2/USCH3<br />
Abryll EPC<br />
EM2<br />
Abryll EPC<br />
EM1/USCH3<br />
Abryll EPC<br />
EM1<br />
Abryll EPC<br />
EM3/USCH3<br />
Abryll EPC<br />
EM3<br />
Abryll EPC<br />
AD3 /USCH 3<br />
Abryll EPC<br />
AD3<br />
Single point panic<br />
exit device<br />
Single point<br />
emergency exit<br />
device<br />
Single point<br />
emergency exit<br />
device<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
Single point locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
Key and lever handle Panic bar S, T, U, V, W, X<br />
Y, Z and AA<br />
Key and lever handle Push pad S, T, U, V, W, X<br />
Y, Z and AA<br />
Key and lever handle Lever handle S, T, U, V, W, X<br />
Y, Z and AA<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Key and lever handle<br />
None<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and lever handle<br />
AE, AF, AG, AH,<br />
AJ, AL, AN, AP,<br />
AR, AT and AV<br />
-<br />
AE, AF, AG, AH,<br />
AJ, AL, AN, AP,<br />
AR, AT and AV<br />
-<br />
AE, AF, AG, AH,<br />
AJ, AL, AN, AP,<br />
AR, AT and AV<br />
-<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
306 20 Nov 2011
46 Tindall<br />
Engineering<br />
Limited<br />
47 Tindall<br />
Engineering<br />
Limited<br />
48 Tindall<br />
Engineering<br />
Limited<br />
49 Tindall<br />
Engineering<br />
Limited<br />
50 Tindall<br />
Engineering<br />
Limited<br />
51 Tindall<br />
Engineering<br />
Limited<br />
52 Tindall<br />
Engineering<br />
Limited<br />
53 Tindall<br />
Engineering<br />
Limited<br />
54 Tindall<br />
Engineering<br />
Limited<br />
55 Tindall<br />
Engineering<br />
Limited<br />
56 Tindall<br />
Engineering<br />
Limited<br />
57 Tindall<br />
Engineering<br />
Limited<br />
Abryll EPC<br />
MD2/USCH3<br />
Abryll EPC<br />
MD2<br />
Abryll EPC<br />
MD1/USCH3<br />
Abryll EPC<br />
MD1<br />
Abryll EPC<br />
MD3/USCH3<br />
Abryll EPC<br />
MD3<br />
Abryll EPC<br />
SATE<br />
EM2/USCH3<br />
Abryll EPC<br />
SATE<br />
EM1/USCH3<br />
Abryll EPC<br />
SATE<br />
EM3/USCH3<br />
Abryll EPC<br />
SATE<br />
AD2/USCH3<br />
Abryll EPC<br />
SATE<br />
AD1/USCH3<br />
Abryll EPC<br />
SATE<br />
AD3/USCH3<br />
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point panic<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Single point<br />
emergency exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point<br />
emergency exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Single point panic<br />
exit device w ith<br />
automatic<br />
deadlocking<br />
Single point<br />
emergency exit<br />
device w ith<br />
automatic<br />
deadlocking<br />
Single point<br />
emergency exit<br />
device w ith<br />
automatic<br />
deadlocking<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push pad<br />
Key or thumb turn<br />
and push pad<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and lever handle<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
Panic bar S, T, U, V, W, X,<br />
Y, Z and AA<br />
Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Panic bar S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
20 Nov 2011 307
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
58 Tindall<br />
Engineering<br />
Limited<br />
59 Tindall<br />
Engineering<br />
Limited<br />
60 Tindall<br />
Engineering<br />
Limited<br />
61 Tindall<br />
Engineering<br />
Limited<br />
62 Tindall<br />
Engineering<br />
Limited<br />
63 Tindall<br />
Engineering<br />
Limited<br />
64 Tindall<br />
Engineering<br />
Limited<br />
65 Tindall<br />
Engineering<br />
Limited<br />
66 Tindall<br />
Engineering<br />
Limited<br />
67 Tindall<br />
Engineering<br />
Limited<br />
68 Tindall<br />
Engineering<br />
Limited<br />
69 Tindall<br />
Engineering<br />
Limited<br />
Abryll EPC<br />
SATE<br />
MD2/USCH3<br />
Abryll EPC<br />
SATE<br />
MD1/USCH3<br />
Abryll EPC<br />
SATE<br />
MD3/USCH3<br />
Mico 942 /ELK<br />
3<br />
Mico 942<br />
Mico 942P<br />
/ELK 3<br />
Mico 942P<br />
Mico 942L<br />
/ELK 3<br />
Mico 942L<br />
Mico 942 EM<br />
SEC<br />
/USCH 3<br />
Mico 942 EM<br />
SEC<br />
Mico 942P EM<br />
SEC /USCH 3<br />
Single point panic<br />
exit device w ith<br />
manual deadlocking<br />
Single point<br />
emergency exit<br />
device w ith manual<br />
deadlocking<br />
Single point<br />
emergency exit<br />
device w ith manual<br />
deadlocking<br />
2-w ay panic exit<br />
device<br />
2-w ay panic exit<br />
device<br />
2-w ay emergency<br />
exit device<br />
2-w ay emergency<br />
exit device<br />
2-w ay emergency<br />
exit device<br />
2-w ay emergency<br />
exit device<br />
2- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
2- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
2- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Key and lever handle Panic bar S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Panic bar A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q and R<br />
None Panic bar -<br />
Key (via ELK 3) and<br />
lever handle<br />
Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q and R<br />
None Push pad -<br />
Key (via ELK 3) and<br />
lever handle<br />
Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q and R<br />
None Lever handle -<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
A, B, C, D, E, F,<br />
G, H, I, J, K, L, M,<br />
N, O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
308 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
70 Tindall<br />
Engineering<br />
Limited<br />
Mico 942P EM<br />
SEC<br />
2- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
-<br />
71 Tindall<br />
Engineering<br />
Limited<br />
Mico 942L EM<br />
SEC /USCH 3<br />
2- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
72 Tindall<br />
Engineering<br />
Limited<br />
Mico 942L EM<br />
SEC<br />
2- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
-<br />
73 Tindall<br />
Engineering<br />
Limited<br />
74 Tindall<br />
Engineering<br />
Limited<br />
75 Tindall<br />
Engineering<br />
Limited<br />
76 Tindall<br />
Engineering<br />
Limited<br />
77 Tindall<br />
Engineering<br />
Limited<br />
78 Tindall<br />
Engineering<br />
Limited<br />
79 Tindall<br />
Engineering<br />
Limited<br />
80 Tindall<br />
Engineering<br />
Limited<br />
81 Tindall<br />
Engineering<br />
Limited<br />
Mico 942L INT<br />
AD /USCH 3<br />
Mico 942L INT<br />
AD<br />
Mico 942 INT<br />
MD /USCH 3<br />
Mico 942 INT<br />
MD<br />
Mico 942P INT<br />
MD /USCH 3<br />
Mico 942P INT<br />
MD<br />
Mico 942L INT<br />
MD /USCH 3<br />
Mico 942L INT<br />
MD<br />
Mico 942<br />
SATE EM SEC<br />
/USCH 3<br />
2-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
2-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2- w ay panic exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Key and lever handle Thumb turn and lever<br />
handle<br />
None<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Key (via USCH 3)<br />
and lever handle<br />
None<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Thumb turn and lever<br />
handle<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push pad<br />
Key or thumb turn<br />
and push pad<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and lever handle<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Push plate A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
20 Nov 2011 309
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
82 Tindall<br />
Engineering<br />
Limited<br />
83 Tindall<br />
Engineering<br />
Limited<br />
84 Tindall<br />
Engineering<br />
Limited<br />
85 Tindall<br />
Engineering<br />
Limited<br />
86 Tindall<br />
Engineering<br />
Limited<br />
87 Tindall<br />
Engineering<br />
Limited<br />
88 Tindall<br />
Engineering<br />
Limited<br />
89 Tindall<br />
Engineering<br />
Limited<br />
Mico 942<br />
SATE EM SEC<br />
Mico 942P<br />
SATE EM SEC<br />
/USCH 3<br />
2- w ay panic exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
2- w ay emergency<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Mico 942P 2- w ay emergency<br />
SATE EM SEC exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Mico 942L 2- w ay emergency<br />
SATE EM SEC exit device w ith<br />
/USCH 3 solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Mico 942L<br />
SATE EM SEC<br />
Mico 942<br />
SATE AD /<br />
USCH 3<br />
Mico 942P<br />
SATE AD /<br />
USCH 3<br />
Mico 942L<br />
SATE AD /<br />
USCH 3<br />
2- w ay emergency<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
2-w ay panic exit<br />
device w ith<br />
automatic<br />
deadlocking<br />
2-w ay emergency<br />
exit device w ith<br />
automatic<br />
deadlocking<br />
2-w ay emergency<br />
exit device w ith<br />
automatic<br />
deadlocking<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Push plate -<br />
Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Push pad -<br />
Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Lever handle -<br />
Key and lever handle Panic bar A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
310 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
90 Tindall<br />
Engineering<br />
Limited<br />
91 Tindall<br />
Engineering<br />
Limited<br />
92 Tindall<br />
Engineering<br />
Limited<br />
93 Tindall<br />
Engineering<br />
Limited<br />
94 Tindall<br />
Engineering<br />
Limited<br />
95 Tindall<br />
Engineering<br />
Limited<br />
96 Tindall<br />
Engineering<br />
Limited<br />
97 Tindall<br />
Engineering<br />
Limited<br />
98 Tindall<br />
Engineering<br />
Limited<br />
99 Tindall<br />
Engineering<br />
Limited<br />
100 Tindall<br />
Engineering<br />
Limited<br />
Mico 942<br />
SATE MD /<br />
USCH 3<br />
Mico 942P<br />
SATE MD /<br />
USCH 3<br />
Mico 942L<br />
SATE MD /<br />
USCH 3<br />
Mico 942<br />
/EURO<br />
ELK 3<br />
Mico 942P<br />
/EURO<br />
ELK 3<br />
Mico 942L<br />
/EURO<br />
ELK 3<br />
Mico 942 EPC<br />
EM SEC<br />
/USCH 3<br />
Mico 942 EPC<br />
EM SEC<br />
2-w ay panic exit<br />
device w ith manual<br />
deadlocking<br />
2-w ay emergency<br />
exit device w ith<br />
manual deadlocking<br />
2-w ay emergency<br />
exit device w ith<br />
manual deadlocking<br />
2-w ay panic exit<br />
device<br />
2-w ay emergency<br />
exit device<br />
2-w ay emergency<br />
exit device<br />
2- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
2- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Mico 942P EPC 2- w ay locking<br />
EM SEC /USCH system w ith solenoid<br />
3<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Mico 942P EPC<br />
EM SEC<br />
2- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Mico 942L EPC 2- w ay locking<br />
EM SEC /USCH system w ith solenoid<br />
3<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Key and lever handle Panic bar A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key (via ELK 3) and<br />
lever handle<br />
Key (via ELK 3) and<br />
lever handle<br />
Key (via ELK 3) and<br />
lever handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Panic bar S, T, U, V, W, X,<br />
Y, Z and AA<br />
Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
AE, AF, AG, AH,<br />
AJ, AL, AN, AP,<br />
AR, AT and AV<br />
-<br />
AE, AF, AG, AH,<br />
AJ, AL, AN, AP,<br />
AR, AT and AV<br />
-<br />
AE, AF, AG, AH,<br />
AJ, AL, AN, AP,<br />
AR, AT and AV<br />
20 Nov 2011 311
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
101 Tindall<br />
Engineering<br />
Limited<br />
Mico 942L EPC<br />
EM SEC<br />
2- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
-<br />
102 Tindall<br />
Engineering<br />
Limited<br />
103 Tindall<br />
Engineering<br />
Limited<br />
104 Tindall<br />
Engineering<br />
Limited<br />
105 Tindall<br />
Engineering<br />
Limited<br />
106 Tindall<br />
Engineering<br />
Limited<br />
107 Tindall<br />
Engineering<br />
Limited<br />
Mico 942L EPC<br />
INT AD /USCH<br />
3<br />
Mico 942L EPC<br />
INT AD<br />
Mico 942 EPC<br />
INT MD /USCH<br />
3<br />
Mico 942 EPC<br />
INT MD<br />
Mico 942P EPC<br />
INT MD /USCH<br />
3<br />
Mico 942P EPC<br />
INT MD<br />
2-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
2-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push pad<br />
Key or thumb turn<br />
and push pad<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
108 Tindall<br />
Engineering<br />
Limited<br />
109 Tindall<br />
Engineering<br />
Limited<br />
110 Tindall<br />
Engineering<br />
Limited<br />
111 Tindall<br />
Engineering<br />
Limited<br />
Mico 942L EPC<br />
INT MD /USCH<br />
3<br />
Mico 942L EPC<br />
INT MD<br />
Mico 942 EPC<br />
SATE EM SEC<br />
/USCH 3<br />
Mico 942 EPC<br />
SATE EM SEC<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2- w ay panic exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
2- w ay panic exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Key and lever handle<br />
None<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and lever handle<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
Push plate S, T, U, V, W, X,<br />
Y, Z and AA<br />
Push plate -<br />
312 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
112 Tindall<br />
Engineering<br />
Limited<br />
113 Tindall<br />
Engineering<br />
Limited<br />
114 Tindall<br />
Engineering<br />
Limited<br />
115 Tindall<br />
Engineering<br />
Limited<br />
116 Tindall<br />
Engineering<br />
Limited<br />
117 Tindall<br />
Engineering<br />
Limited<br />
118 Tindall<br />
Engineering<br />
Limited<br />
119 Tindall<br />
Engineering<br />
Limited<br />
120 Tindall<br />
Engineering<br />
Limited<br />
121 Tindall<br />
Engineering<br />
Limited<br />
122 Tindall<br />
Engineering<br />
Limited<br />
123 Tindall<br />
Engineering<br />
Limited<br />
Mico 942P EPC<br />
SATE EM SEC<br />
/USCH 3<br />
2- w ay emergency<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Mico 942P EPC 2- w ay emergency<br />
SATE EM SEC exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 8<br />
Mico 942L EPC 2- w ay emergency<br />
SATE EM SEC exit device w ith<br />
/USCH 3 solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Mico 942L EPC<br />
SATE EM SEC<br />
Mico 942 EPC<br />
SATE AD /<br />
USCH 3<br />
Mico 942P EPC<br />
SATE AD /<br />
USCH 3<br />
Mico 942L EPC<br />
SATE AD /<br />
USCH 3<br />
Mico 942 EPC<br />
SATE MD /<br />
USCH 3<br />
2- w ay emergency<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
2-w ay panic exit<br />
device w ith<br />
automatic<br />
deadlocking<br />
2-w ay emergency<br />
exit device w ith<br />
automatic<br />
deadlocking<br />
2-w ay emergency<br />
exit device w ith<br />
automatic<br />
deadlocking<br />
2-w ay panic exit<br />
device w ith manual<br />
deadlocking<br />
Mico 942P EPC 2-w ay emergency<br />
SATE MD / exit device w ith<br />
USCH 3 manual deadlocking<br />
Mico 942L EPC 2-w ay emergency<br />
SATE MD / exit device w ith<br />
USCH 3 manual deadlocking<br />
Mico 942-3<br />
/ELK 3<br />
Mico 942-3<br />
3-w ay panic exit<br />
device<br />
3-w ay panic exit<br />
device<br />
Electro-mechanical<br />
access control<br />
device 9 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
Push pad -<br />
Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
Lever handle -<br />
Key and lever handle Panic bar S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Panic bar S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Panic bar A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q and R<br />
None Panic bar -<br />
20 Nov 2011 313
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
124 Tindall<br />
Engineering<br />
Limited<br />
125 Tindall<br />
Engineering<br />
Limited<br />
126 Tindall<br />
Engineering<br />
Limited<br />
127 Tindall<br />
Engineering<br />
Limited<br />
128 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3P<br />
/ELK 3<br />
Mico 942-3P<br />
Mico 942-3L<br />
/ELK 3<br />
Mico 942-3L<br />
Mico 942-3<br />
EM SEC<br />
/USCH 3<br />
3-w ay emergency<br />
exit device<br />
3-w ay emergency<br />
exit device<br />
3-w ay emergency<br />
exit device<br />
3-w ay emergency<br />
exit device<br />
3- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Key and lever handle Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q and R<br />
None Push pad -<br />
Key and lever handle Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q and R<br />
None Lever handle -<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
129 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3<br />
EM SEC<br />
3- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
-<br />
130 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3P 3- w ay locking<br />
EM SEC /USCH system w ith solenoid<br />
3<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
131 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3P<br />
EM SEC<br />
3- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
-<br />
132 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3L 3- w ay locking<br />
EM SEC /USCH system w ith solenoid<br />
3<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 9 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
133 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3L<br />
EM SEC<br />
3- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 8<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
-<br />
134 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3L<br />
INT AD /USCH<br />
3<br />
3-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
Key and lever handle Thumb turn and lever<br />
handle<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
314 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
135 Tindall<br />
Engineering<br />
Limited<br />
136 Tindall<br />
Engineering<br />
Limited<br />
137 Tindall<br />
Engineering<br />
Limited<br />
138 Tindall<br />
Engineering<br />
Limited<br />
139 Tindall<br />
Engineering<br />
Limited<br />
140 Tindall<br />
Engineering<br />
Limited<br />
141 Tindall<br />
Engineering<br />
Limited<br />
142 Tindall<br />
Engineering<br />
Limited<br />
143 Tindall<br />
Engineering<br />
Limited<br />
144 Tindall<br />
Engineering<br />
Limited<br />
145 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3L<br />
INT AD<br />
Mico 942-3 INT<br />
MD /USCH 3<br />
Mico 942-3 INT<br />
MD<br />
Mico 942-3P<br />
INT MD /USCH<br />
3<br />
Mico 942-3P<br />
INT MD<br />
Mico 942-3L<br />
INT MD /USCH<br />
3<br />
Mico 942-3L<br />
INT MD<br />
Mico 942-3<br />
SATE EM SEC<br />
/USCH 3<br />
Mico 942-3<br />
SATE EM SEC<br />
Mico 942-3P<br />
SATE EM SEC<br />
/USCH 3<br />
Mico 942-3P<br />
SATE EM SEC<br />
3-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
3- w ay panic exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
3- w ay panic exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
3- w ay emergency<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
3- w ay emergency<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
None<br />
Key (via USCH 3)<br />
and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Thumb turn and lever<br />
handle<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push pad<br />
Key or thumb turn<br />
and push pad<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and lever handle<br />
-<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
-<br />
Push plate A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Push plate -<br />
Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Push pad -<br />
20 Nov 2011 315
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
146 Tindall<br />
Engineering<br />
Limited<br />
147 Tindall<br />
Engineering<br />
Limited<br />
148 Tindall<br />
Engineering<br />
Limited<br />
149 Tindall<br />
Engineering<br />
Limited<br />
150 Tindall<br />
Engineering<br />
Limited<br />
151 Tindall<br />
Engineering<br />
Limited<br />
152 Tindall<br />
Engineering<br />
Limited<br />
153 Tindall<br />
Engineering<br />
Limited<br />
154 Tindall<br />
Engineering<br />
Limited<br />
155 Tindall<br />
Engineering<br />
Limited<br />
156 Tindall<br />
Engineering<br />
Limited<br />
157 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3L 3- w ay emergency<br />
SATE EM SEC exit device w ith<br />
/USCH 3 solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Mico 942-3L<br />
SATE EM SEC<br />
Mico 942-3<br />
SATE AD /<br />
USCH 3<br />
Mico 942-3P<br />
SATE AD /<br />
USCH 3<br />
Mico 942-3L<br />
SATE AD /<br />
USCH 3<br />
Mico 942-3<br />
SATE MD /<br />
USCH 3<br />
Mico 942-3P<br />
SATE MD /<br />
USCH 3<br />
Mico 942-3L<br />
SATE MD /<br />
USCH 3<br />
Mico 942-3<br />
/EURO ELK 3<br />
Mico 942-3P<br />
/EURO ELK 3<br />
Mico 942-3L<br />
/EURO ELK 3<br />
Mico 942-3<br />
EPC EM SEC<br />
/USCH 3<br />
3- w ay emergency<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
3-w ay panic exit<br />
device w ith<br />
automatic<br />
deadlocking<br />
3-w ay emergency<br />
exit device w ith<br />
automatic<br />
deadlocking<br />
3-w ay emergency<br />
exit device w ith<br />
automatic<br />
deadlocking<br />
3-w ay panic exit<br />
device w ith manual<br />
deadlocking<br />
3-w ay emergency<br />
exit device w ith<br />
manual deadlocking<br />
3-w ay emergency<br />
exit device w ith<br />
manual deadlocking<br />
3-w ay panic exit<br />
device<br />
3-w ay emergency<br />
exit device<br />
3-w ay emergency<br />
exit device<br />
3- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Lever handle -<br />
Key and lever handle Panic bar A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Panic bar A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Push pad A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Lever handle A, B, C, D, E, F, G,<br />
H, I, J, K, L, M, N,<br />
O, P, Q, R, AW,<br />
AX, AY, AZ, BA,<br />
BB and BC<br />
Key and lever handle Panic bar S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
AE, AF, AG, AH,<br />
AJ, AL, AN, AP,<br />
AR, AT and AV<br />
316 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
158 Tindall<br />
Engineering<br />
Limited<br />
159 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3<br />
EPC EM SEC<br />
Mico 942-3P<br />
EPC EM SEC<br />
/USCH 3<br />
3- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
3- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push plate<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
-<br />
AE, AF, AG, AH,<br />
AJ, AL, AN, AP,<br />
AR, AT and AV<br />
160 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3P<br />
EPC EM SEC<br />
3- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
push pad<br />
-<br />
161 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3L<br />
EPC EM SEC<br />
/USCH 3<br />
3- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
AE, AF, AG, AH,<br />
AJ, AL, AN, AP,<br />
AR, AT and AV<br />
162 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3L<br />
EPC EM SEC<br />
3- w ay locking<br />
system w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device w ith thumb<br />
turn override and<br />
lever handle<br />
-<br />
163 Tindall<br />
Engineering<br />
Limited<br />
164 Tindall<br />
Engineering<br />
Limited<br />
165 Tindall<br />
Engineering<br />
Limited<br />
166 Tindall<br />
Engineering<br />
Limited<br />
167 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3L<br />
EPC INT AD<br />
/USCH 3<br />
Mico 942-3L<br />
EPC INT AD<br />
Mico 942-3<br />
EPC INT MD<br />
/USCH 3<br />
Mico 942-3<br />
EPC INT MD<br />
Mico 942-3P<br />
EPC INT MD<br />
/USCH 3<br />
3-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
3-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
None<br />
Key and lever handle<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push plate<br />
Key or thumb turn<br />
and push pad<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
20 Nov 2011 317
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
168 Tindall<br />
Engineering<br />
Limited<br />
169 Tindall<br />
Engineering<br />
Limited<br />
170 Tindall<br />
Engineering<br />
Limited<br />
171 Tindall<br />
Engineering<br />
Limited<br />
172 Tindall<br />
Engineering<br />
Limited<br />
173 Tindall<br />
Engineering<br />
Limited<br />
174 Tindall<br />
Engineering<br />
Limited<br />
175 Tindall<br />
Engineering<br />
Limited<br />
176 Tindall<br />
Engineering<br />
Limited<br />
177 Tindall<br />
Engineering<br />
Limited<br />
178 Tindall<br />
Engineering<br />
Limited<br />
Mico 942-3P<br />
EPC INT MD<br />
Mico 942-3L<br />
EPC INT MD<br />
/USCH 3<br />
Mico 942-3L<br />
EPC INT MD<br />
Mico 942-3<br />
EPC SATE EM<br />
SEC /USCH 3<br />
Mico 942-3<br />
EPC SATE EM<br />
SEC<br />
Mico 942-3P<br />
EPC SATE EM<br />
SEC /USCH 3<br />
Mico 942-3P<br />
EPC SATE EM<br />
SEC<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking<br />
system w ith manual<br />
deadlocking<br />
2-w ay locking<br />
system w ith manual<br />
deadlocking<br />
3- w ay panic exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
3- w ay panic exit<br />
device w ith solenoid<br />
deadlocking and 12v<br />
electro-mechanical<br />
access control 9<br />
3- w ay emergency<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
3- w ay emergency<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Mico 942-3L 3- w ay emergency<br />
EPC SATE EM exit device w ith<br />
SEC /USCH 3 solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Mico 942-3L<br />
EPC SATE EM<br />
SEC<br />
3- w ay emergency<br />
exit device w ith<br />
solenoid deadlocking<br />
and 12v electromechanical<br />
access<br />
control 9<br />
Mico 942-3 3-w ay panic exit<br />
EPC SATE AD device w ith<br />
/ USCH 3 automatic<br />
deadlocking<br />
Mico 942-3P 3-w ay emergency<br />
EPC SATE AD exit device w ith<br />
/ USCH 3 automatic<br />
deadlocking<br />
None<br />
Key and lever handle<br />
None<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 w ith key<br />
override and lever<br />
handle<br />
Electro-mechanical<br />
access control<br />
device 10 and lever<br />
handle<br />
Key or thumb turn<br />
and push pad<br />
Key or thumb turn<br />
and lever handle<br />
Key or thumb turn<br />
and lever handle<br />
-<br />
AC, AD, AE, AF,<br />
AG, AH, AI, AJ,<br />
AK, AL, AM, AN,<br />
AO, AP, AQ, AR,<br />
AS, AT, AU and<br />
AV<br />
-<br />
Push plate S, T, U, V, W, X,<br />
Y, Z and AA<br />
Push plate -<br />
Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
Push pad -<br />
Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
Lever handle -<br />
Key and lever handle Panic bar S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
318 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
179 Tindall<br />
Engineering<br />
Limited<br />
180 Tindall<br />
Engineering<br />
Limited<br />
181 Tindall<br />
Engineering<br />
Limited<br />
182 Tindall<br />
Engineering<br />
Limited<br />
183 Tindall<br />
Engineering<br />
Limited<br />
184 Bradbury<br />
Security<br />
Compatible Cylinders<br />
Mico 942-3L 3-w ay emergency<br />
EPC SATE AD exit device w ith<br />
/ USCH 3 automatic<br />
deadlocking<br />
Mico 942-3 3-w ay panic exit<br />
EPC SATE MD device w ith manual<br />
/ USCH 3 deadlocking<br />
Mico 942-3P 3-w ay emergency<br />
EPC SATE MD exit device w ith<br />
/ USCH 3 manual deadlocking<br />
Mico 942-3L 3-w ay emergency<br />
EPC SATE MD exit device w ith<br />
/ USCH 3 manual deadlocking<br />
HSTB Tw o surface<br />
mounted drop bolts<br />
- Tw o surface<br />
mounted drop bolts<br />
Key and lever handle Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Panic bar S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Push pad S, T, U, V, W, X,<br />
Y, Z and AA<br />
Key and lever handle Lever handle S, T, U, V, W, X,<br />
Y, Z and AA<br />
None<br />
None<br />
Surface mounted<br />
drop bolts<br />
Surface mounted<br />
drop bolts<br />
-<br />
-<br />
Cylinder Manufacturer Model Type<br />
Reference<br />
A Abloy Protec CY201 PT Scandinavian Oval<br />
B Abloy Disklock Pro CY201 DP Scandinavian Oval<br />
C Abloy Protec Cliq CY201 Scandinavian Oval<br />
D AMS CL-OVLD Scandinavian Oval<br />
E ASSA 4401dp Scandinavian Oval<br />
F ASSA 4401 Cliq Scandinavian Oval<br />
G ASSA 4407dp Scandinavian Oval<br />
H ASSA 4407 Cliq Scandinavian Oval<br />
I ASSA 4801 Scandinavian Oval<br />
J ASSA 4807 Scandinavian Oval<br />
K ASSA C5801 Scandinavian Oval<br />
L ASSA C5807 Scandinavian Oval<br />
M ASSA Tw in 7601 Scandinavian Oval<br />
N ASSA Tw in 7607 Scandinavian Oval<br />
O Kaba K20 Scandinavian Oval<br />
P Kaba Quattro PluS Scandinavian Oval<br />
Q Locken CL-PL2WR Scandinavian Oval<br />
R Medeco M3-ARX Scandinavian Oval<br />
S ASSA 44M23 Europrofile single cylinder<br />
T Abloy CY307 Protec Europrofile single cylinder<br />
U Abloy CY307 Disclock Pro Europrofile single cylinder<br />
V Abloy CY307 Protec Cliq Europrofile single cylinder<br />
W ASSA 4823 Europrofile single cylinder<br />
X ASSA C5823 Europrofile single cylinder<br />
Y ASSA 7623 Europrofile single cylinder<br />
Z Medico M3 ARX Europrofile single cylinder<br />
AA KABA Quattro PluS Europrofile single cylinder<br />
20 Nov 2011 319
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
AB ISEO R6 Europrofile double cylinder (key:key)<br />
AC Abloy Protec CY304 Europrofile double cylinder (key:key)<br />
AD Abloy Protec Cliq CY304 Europrofile double cylinder (key:key)<br />
AE Abloy Protec CY305 Europrofile double cylinder (key:thumbturn)<br />
AF Abloy Protec Cliq CY305 Europrofile double cylinder (key:thumbturn)<br />
AG Abloy Protec Cliq CY333 Europrofile double cylinder (key:thumbturn)<br />
AH Abloy Protec CY333 Europrofile double cylinder (key:thumbturn)<br />
AI ASSA 4422dp Europrofile double cylinder (key:key)<br />
AJ ASSA 4427dp Europrofile double cylinder (key:thumbturn)<br />
AK ASSA 44M22 Cliq Europrofile double cylinder (key:key)<br />
AL ASSA 44M27 Cliq Europrofile double cylinder (key:thumbturn)<br />
AM ASSA 4822 Europrofile double cylinder (key:key)<br />
AN ASSA 4827 Europrofile double cylinder (key:thumbturn)<br />
AO ASSA C5822 Europrofile double cylinder (key:key)<br />
AP ASSA C5827 Europrofile double cylinder (key:thumbturn)<br />
AQ ASSA 7622 Europrofile double cylinder (key:key)<br />
AR ASSA 7627 Europrofile double cylinder (key:thumbturn)<br />
AS Kaba Quattro PluS Europrofile double cylinder (key:key)<br />
AT Kaba Quattro PluS Europrofile double cylinder (key:thumbturn)<br />
AU Medeco M3-ARX Europrofile double cylinder (key:key)<br />
AV Medeco M3-ARX Europrofile double cylinder (key:thumbturn)<br />
AW Abloy Protec CY403 Rim<br />
AX Abloy Protec Cliq CY403 Rim<br />
AY Kaba Quattro Plus Rim<br />
AZ Medeco M3-ARX Rim<br />
BA AMS CL-CA2D Finish Round<br />
BB ASSA 4857 Round threaded<br />
BC ASSA C5857 Round threaded<br />
Accessories 11<br />
Accessory<br />
Flat sill 12<br />
Low profile aluminium sill 12<br />
No sill 12<br />
13, 14, 15<br />
Vision panel<br />
Description<br />
3 mm flat plate sill<br />
Low profile aluminium sill<br />
No sill<br />
356 mm high by 203 mm w ide vision panel incorporating a 45.04 mm thick specialist laminated<br />
double glazed security glazing unit<br />
762 mm high by 203 mm w ide vision panel incorporating a 45.04 mm thick specialist laminated<br />
double glazed security glazing unit<br />
457 mm high by 457 mm w ide vision panel incorporating a 45.04 mm thick specialist laminated<br />
double glazed security glazing unit<br />
356 mm high by 203 mm w ide vision panel incorporating a 45.5 mm thick specialist laminated<br />
security glass<br />
762 mm high by 203 mm w ide vision panel incorporating a 45.5 mm thick specialist laminated<br />
security glass<br />
457 mm high by 457 mm w ide vision panel incorporating a 45.5 mm thick specialist laminated<br />
security glass<br />
Notes:<br />
1. When fitted with compatible lock option 1 the security rating applies to doorsets with the locking mechanisms fully engaged, i.e. in<br />
optimum locked condition. The single leaf doorset achieves Security Rating 1 when left in the minimum locked condition, i.e. when the<br />
key is turned once and removed. The double doorset also achieves Security Rating 1 when left in the minimum locked condition, i.e.<br />
only one surface mounted drop bolt on the passive leaf engaged and the key on the active leaf thrown once and removed.<br />
2. When fitted with compatible lock option 2 the security rating is also achieved by the doorset when in the minimum locked condition,<br />
i.e. when both surface mounted drop bolts on the passive leaf are disengaged.<br />
3. When fitted with the Mico compatible lock options 3 to182 the security rating applies to doorsets with the locking mechanisms fully<br />
engaged, i.e. in optimum locked condition. The single leaf and double leaf doorsets achieve Security Rating 1 when left in the<br />
minimum locked condition.<br />
4. The M2M3 double leaf doorsets can be produced with leafs of unequal width. The maximum width of both leafs is 1100 mm. The<br />
minimum width of the active leaf is 750 mm. The minimum width of the passive leaf is 400 mm.<br />
5. Although outside the scope of LPS 1175: Issue 7, special consideration should be paid to the use of locking systems with separate<br />
deadlocks, e.g. Mico 942-3 INT MD. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a<br />
panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or emergency device. For<br />
320 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
further information, please refer to the appropriate standards for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125<br />
respectively.<br />
6. Although outside the scope of LPS 1175: Issue 7, special consideration should be paid to the use of single operating panic or<br />
emergency exit devices. This is because it is generally accepted that when two panic or emergency exit devices are fitted to double<br />
doorsets the operation of either device should disengage simultaneously such that both leafs can open. For further information,<br />
please refer to the appropriate standard for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively.<br />
7. The two-way locking systems used on the passive leaf of double doorsets shall incorporate identical internal operation devices to<br />
those on the locking systems used on the active leaf.<br />
8. Certification does not cover the use of locks other than those listed. Utilisation of unlisted locks may affect the level of security offered<br />
by the doorset.<br />
9. Fail secure version only.<br />
10. The resistance of the access control locks to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175.<br />
Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any<br />
access control equipment that may be used to operate these locking systems. This is because the scope of access control devices<br />
and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that Ascot Doors<br />
Limited satisfy themselves that the components are either resistant to mechanical and other forms of tampering/abuse, or that they<br />
are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the<br />
locking system to disengage.<br />
11. Certification does not cover the use of vision panels or other accessories that are not listed. Utilisation of other accessories may affect<br />
the level of security offered by the doorset.<br />
12. The alternative sill options should not to be fitted to doorsets incorporating panic bars or push pads.<br />
13. The standard (stepped) sill must always be used on doorsets incorporating either glazed apertures or locking mechanisms<br />
incorporating single action escape panic exit systems operated by panic bars.<br />
14. Doorsets fitted with upper and lower glazed apertures should not incorporate hardware operated by a panic bar.<br />
15. The 45.04 mm thick specialist laminated double glazed security glazing unit should only be used on doorsets fitted with compatible<br />
lock option 1 and options 3 to 182 incorporating internal key deadlocks.<br />
C W Fields and Son Limited<br />
Station Road Industrial Estate, Epworth, Nr. Doncaster, South Yorkshire DN9 1JZ, United Kingdom<br />
Tel: +44 (0)1427 872368 • Fax: +44 (0)1427 873057<br />
E-mail: info@cwfields.co.uk • Website: www.cwfields.co.uk<br />
Certificate No: 940a to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product Type<br />
Name<br />
Fields<br />
Security<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Single leaf outward 0.705 2.605 0.382 0.997 2 940a/01<br />
opening hinged<br />
security<br />
doorset<br />
Single leaf outward 0.955 3.055 0.382 0.997 2 940a/02<br />
over panels 1<br />
opening hinged<br />
security<br />
doorset with<br />
fixed/removable<br />
Single leaf inward 0.705 2.605 0.382 0.997 2 940a/03<br />
opening hinged<br />
security<br />
doorset<br />
Single leaf inward 0.955 3.055 0.382 0.997 2 940a/04<br />
over panels 1<br />
opening hinged<br />
security<br />
doorset with<br />
fixed/removable<br />
Double leaf outward<br />
opening hinged<br />
security<br />
doorset 2 0.705 2.605 0.685 1.915 2 940a/05<br />
Cert.<br />
No.<br />
20 Nov 2011 321
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Product<br />
Name<br />
Type<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Double leaf outward 0.955 3.055 0.685 1.915 2 940a/06<br />
over panels 1, 2<br />
opening hinged<br />
security<br />
doorset with<br />
fixed/removable<br />
Double leaf inward 0.705 2.605 0.685 1.915 2 940a/07<br />
doorset 2<br />
opening hinged<br />
security<br />
Double leaf inward<br />
opening hinged<br />
security<br />
doorset with<br />
fixed/removable<br />
over panels 1, 2 0.955 3.055 0.685 1.915 2 940a/08<br />
Cert.<br />
No.<br />
Approved Locking Configurations<br />
LPCB Ref.<br />
No.<br />
Trade<br />
Name<br />
940a/01 Fields<br />
Security<br />
940a/02 Fields<br />
Security<br />
940a/03 Fields<br />
Security<br />
940a/04 Fields<br />
Security<br />
940a/05 Fields<br />
Security<br />
940a/06 Fields<br />
Security<br />
940a/07 Fields<br />
Security<br />
940a/08 Fields<br />
Security<br />
Compatible Locking Systems<br />
Type<br />
Active Leaf Passive Leaf<br />
Single leaf outw ard opening hinged security 1, 2, 3 N/A<br />
doorset<br />
Single leaf outw ard opening hinged security 1, 2, 3 N/A<br />
doorset w ith fixed/removable over panels 1<br />
Single leaf inw ard opening hinged security 1, 2, 3 N/A<br />
doorset<br />
Single leaf inw ard opening hinged security 1, 2, 3 N/A<br />
doorset w ith fixed/removable over panels 1<br />
Double leaf outw ard opening hinged security 1, 2, 3 4<br />
doorset 2<br />
Double leaf outw ard opening hinged security 1, 2, 3 4<br />
doorset w ith fixed/removable over panels 1,2<br />
Double leaf inw ard opening hinged security 1, 2, 3 4<br />
doorset 2<br />
Double leaf inw ard opening hinged security 1, 2, 3 4<br />
doorset w ith fixed/removable over panels 1,2<br />
Compatible Locking Systems<br />
322 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Compatible<br />
Locking<br />
System<br />
Manufacturer Model Operating Devices<br />
1 Surelock McGill<br />
Limited<br />
2 Surelock McGill<br />
Limited<br />
3 Surelock McGill<br />
Limited<br />
4 Surelock McGill<br />
Limited<br />
External<br />
Face<br />
Internal<br />
Face<br />
SL325- E1K2O2 PW Electromechanical<br />
Single action<br />
lever handle<br />
access<br />
control lock<br />
(fail secure)<br />
w ith key<br />
override and<br />
lever handle<br />
SL325-E1W Electromechanical<br />
Single action<br />
lever handle<br />
access<br />
control lock<br />
(fail secure)<br />
w ith lever<br />
handle<br />
SL315- E1K2O2PW Key and lever Single action<br />
handle lever handle<br />
TBFW barrel bolts None Tw o barrel<br />
bolts<br />
Compatible<br />
Cylinders<br />
A<br />
A<br />
A<br />
N/A<br />
Compatible Cylinders<br />
Cylinder<br />
Reference<br />
Manufacturer Model Type<br />
A Assa C5857 Rim cylinder<br />
Vision Panels<br />
Trade<br />
Name<br />
Fields<br />
Security<br />
Vision Panels<br />
30 mm w ide by 300 mm high vision<br />
panels on leafs at least 567 mm w ide.<br />
Compatible Doorset Configurations<br />
Single<br />
Leaf<br />
Inw ard<br />
Opening<br />
Single<br />
Leaf<br />
Outw ard<br />
Opening<br />
Double<br />
Leaf<br />
Inward<br />
Opening<br />
Double<br />
Leaf<br />
Outward<br />
Opening<br />
<br />
Notes:<br />
1. The maximum door leaf height is 2558 mm.<br />
2. The scope of this approval includes double leaf doorsets with equal and unequal leafs. The maximum individual leaf width is 915 mm<br />
and the minimum individual leaf width is 300 mm.<br />
Clearway Environmental Services (UK) Limited<br />
11 Landau Way, Darent Industrial Park, Erith, Kent DA8 2LF, United Kingdom<br />
Tel: +44 (0)1322 332211 • Fax: +44 (0)1322 339582<br />
E-mail: info@clearwayservices.co.uk • Website: www.clearwayservices.co.uk<br />
Certificate No: 1001a to LPS 1175: Issue 7<br />
20 Nov 2011 323
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Temporary Security Doorset<br />
Product<br />
Name<br />
Configuration Minimum<br />
Structural<br />
Opening<br />
Height 1<br />
Toreadoor<br />
Single leaf,<br />
outward<br />
opening,<br />
hinged<br />
temporary 3<br />
security<br />
doorset<br />
Maximum<br />
Structural<br />
Opening<br />
Height 1<br />
Minimum<br />
Structural<br />
Opening<br />
Width 1<br />
Maximum<br />
Structural<br />
Opening<br />
Width 1<br />
Minimum<br />
Structural<br />
Opening<br />
Depth 2<br />
Maximum<br />
Structural<br />
Opening<br />
Depth 2<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
(m) (m) (m) (m) (m) (m)<br />
1.61 1.93 0.37 0.76 0.045 0.25 1 1001a<br />
4<br />
Manufacturer Model Type Compatible Opening Devices<br />
Compatible Locking Systems<br />
External Face Internal Face<br />
Willenhall M1 Clearw ays 5-lever mortice deadlock Key and handle Key and handle<br />
Clearw ay Centurion Electronic locking system 5 Keypad Manual actuator<br />
Notes:<br />
1. The doorset is available in one fixed size to suit a range of structural opening sizes.<br />
2. Maximum depth of the aperture within the supporting substrate 6 that the doorset can be fitted within.<br />
3. The doorset is designed to be fitted to unoccupied properties.<br />
4. Both locking systems are fitted to the doorset. The security rating was achieved by the doorset with only one lock engaged, i.e. the<br />
minimum locked condition. The doorset also achieved Security Rating 1 in the optimum locked condition, i.e. with both locks engaged.<br />
5. The resistance of the electronic locking system to “non-mechanical” attack has not been assessed because it is outside the scope of<br />
LPS 1175: Issue 7.<br />
6. The doorset is suitable for installation 7 into timber, brickwork, steel, blockwork, concrete and aluminium substrates.<br />
7. The doorset should be installed in accordance with the installation instructions ‘Fitting / Fixing instructions for the Toreadoor Keyless<br />
Door’ dated 13 October 2011.<br />
Design & Supply Limited<br />
13 Pant Industrial Estate, Merthyr Tydfil, Mid Glamorgan CF48 2SR, United Kingdom<br />
Tel: +44 (0)1685 350114 • Fax: +44 (0)1685 723276<br />
E-mail: dsl@designandsupply.co.uk<br />
Certificate No: 694b to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product Name Type Minimum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
Desray Single leaf outward opening<br />
Maximum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert. No.<br />
1.8 <strong>2.2</strong> 0.75 1.1 2 694b/01<br />
hinged security doorset<br />
Double leaf outward opening 1.8 <strong>2.2</strong> 1.5 2.5 2 694b/02<br />
hinged security doorset 1<br />
Approved Locking Configurations<br />
LPCB Ref. No. Product Name Type<br />
694b/01 Desray Single leaf outw ard<br />
opening hinged<br />
security doorset<br />
694b/02 Desray Double leaf outw ard<br />
opening hinged<br />
security doorset<br />
Com patible Locking System<br />
Active Leaf Passive Leaf<br />
1, 2, 3, 4, 6, 7, 8 -<br />
1, 2, 3, 4, 6, 7, 8 5 2 , 9<br />
324 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Compatible Locking Systems<br />
Compatible<br />
Locking<br />
Systems<br />
Manufacturer<br />
Model<br />
Type<br />
Compatible Operating<br />
Devices<br />
External Face Internal Face<br />
1 Assa 765 Sash lock Key and lever Key and lever A<br />
handle handle<br />
2 Assa 765 Sash lock Key and lever Thumbturn and B<br />
handle lever handle<br />
3 Assa 2788 Dead lock Key Key A<br />
4 Assa 2788 Dead lock Key Thumbturn B<br />
5 Exidor 802 Tw o point panic exit None Panic bar N/A<br />
device<br />
6 Exidor 803 Three point panic exit None Panic bar N/A<br />
device 3<br />
7 Exidor 803 w ith 809 Three point panic exit<br />
device w ith outside<br />
access device 3<br />
Key via Exidor<br />
809 outside<br />
access device<br />
Panic bar C<br />
8 Exidor 803 w ith 810 Three point panic exit<br />
device w ith outside<br />
access device 3<br />
Key via Exidor<br />
810 outside<br />
access device<br />
Panic bar<br />
Compatible<br />
Cylinder<br />
9 Exidor HS923/10 Tw o tow er bolts None Tow er bolts N/A<br />
Compatible Cylinders<br />
Cylinder Manufacturer Model Type<br />
Reference<br />
A Assa C5802 Double oval cylinder (key:key)<br />
Accessories<br />
B Assa C5801 Double oval cylinder (key:thumbturn)<br />
C Zone 1850 Single europrofile cylinder<br />
Accessory Description EXECDOOR doorsets<br />
Sherman vision panel 4 40.5 mm thick vision panels of maximum dimensions 400 mm by<br />
400 mm. These may either be located central to the w idth of the<br />
leaf or offset from leading edge by 150 mm.<br />
Chieftain vision panel 4 27.8 mm thick vision panels of maximum dimensions 400 mm by<br />
400 mm. These may either be located central to the w idth of the<br />
leaf or offset from leading edge by 150 mm.<br />
AB26 vision panel 27 mm thick vision panels of maximum dimensions 400 mm by 400<br />
mm. These may either be located central to the w idth of the leaf<br />
or offset from leading edge by 150 mm.<br />
The following table confirms which combinations of vision panel and locking system may be used together.<br />
Com patible Locking<br />
Compatible Vision Panels<br />
Systems<br />
1 Sherman, Chieftain and AB26<br />
Notes:<br />
2 Sherman and AB26<br />
3 Sherman, Chieftain and AB26<br />
4 Sherman and AB26<br />
5 Sherman and AB26<br />
6 Sherman and AB26<br />
7 Sherman and AB26<br />
8 Sherman and AB26<br />
9 Sherman, Chieftain and AB26<br />
C<br />
694b/01 694b/02<br />
<br />
<br />
<br />
<br />
<br />
<br />
20 Nov 2011 325
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
1. Double leaf Desray doorsets may incorporate leafs of equal or unequal width. Leafs of unequal width will comprise of an active leaf<br />
exactly twice as wide as the passive leaf. The maximum leaf width is 1350 mm and the minimum leaf width is 500 mm.<br />
2. This locking system may only be used on the passive leaf and then only if locking systems 6, 7 or 8 are used on the active leaf.<br />
3. Locking systems 6, 7 and 8 may not comply with fire escape regulations relating to potential panic situations if fitted to double leaf<br />
doorsets. This is because activation of the device on one leaf may not necessarily release the other leaf and in some cases may not<br />
release the leaf to which it is fitted.<br />
4. These vision panels incorporate obscurable panels controlled by a handle on the protected side of the doorset.<br />
IR Martin Roberts, IR Security & Safety Limited<br />
Millen Road, Sittingbourne, Kent ME10 2AA, United Kingdom<br />
Tel: +44 (0)1795 476161 • Fax: +44 (0)1795 422463<br />
E-mail: martin_roberts@eu.irco.com • Website: www.irmartinroberts.co.uk<br />
Certificate No: 322a to LPS 1175: Issue 5<br />
Hinged Security Doorsets<br />
Product Name Type Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Martin Roberts Single leaf, outward opening<br />
SD5003 Range<br />
Martin Roberts<br />
SD5001<br />
hinged security doorset<br />
Single leaf, outward opening<br />
hinged security doorsets<br />
Single leaf, inward opening<br />
hinged security doorsets<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.951 3.049 0.503 1.322 3 322a/01<br />
0.951 3.049 0.503 1.322 1 322a/02<br />
0.951 <strong>2.2</strong>5 0.503 1.322 1<br />
Approved Locking Configurations<br />
LPCB Ref. No. Trade Name Type Compatible Locking Systems<br />
322a/01 Martin Roberts SD5003 Single leaf, outw ard opening hinged security doorset 1, 2, 4, 6, 7, 8, 9, 10, 11, 12 and 13<br />
322a/02 Martin Roberts SD5001 1<br />
Compatible Locking Systems<br />
Single leaf, outw ard opening hinged security doorset 5<br />
Single leaf, inw ard opening hinged security doorset 3<br />
Option Locking System Type Compatible External and Internal Operating Devices<br />
External<br />
Internal<br />
1 Assa 765 Sash Lock Key via an Assa 6501 single<br />
cylinder or an Assa 6502 double<br />
cylinder<br />
Key plus lever handle<br />
or<br />
Key plus thumb-turn<br />
2 Assa 500/9 Mortice Locking Latch Key via an Assa 6501 single<br />
cylinder<br />
Assa Mico 944 panic latch<br />
or<br />
Briton 379 panic operator<br />
or Lever handle<br />
3 Assa 1520 Escape Sash Lock Key via an Assa 4801 single<br />
cylinder<br />
or<br />
Key via an Assa 4802 double<br />
cylinder<br />
Assa 6650C solid brass handle<br />
plus either:<br />
Assa 6256 thumbturn<br />
or<br />
Key via an Assa 4802 double<br />
cylinder<br />
4 Assa 8761 Emergency Nightlatch Key via an Assa 6501 single<br />
cylinder<br />
Assa Mico 944 panic latch<br />
or<br />
Briton 379 panic operator<br />
or<br />
Lever handle<br />
326 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
5 Assa 8761 Emergency Nightlatch Key via an Assa 4801 single Assa 640 solid brass handle<br />
cylinder<br />
6 Assa 9788 Mortice Deadlock Key via an Assa 6501 single<br />
cylinder or an Assa 6502 double<br />
cylinder<br />
Key<br />
or<br />
Thumb-turn<br />
7 2 Assa 8761<br />
and<br />
Assa 9788<br />
Emergency Nightlatch<br />
and<br />
Mortice Deadlock<br />
Tw o separate keys via Assa<br />
6501 or Assa 6502 cylinders<br />
Combination of either:<br />
Assa Mico 944 panic latch,<br />
Briton 379 panic operator or<br />
Lever handle, and either:<br />
key or thumb-turn<br />
8 Assa 9788 (Tw o fitted) Mortice Deadlocks Key via an Assa 6501 single or<br />
Assa 6502 double cylinder<br />
9 Security Engineering plc<br />
SI1216<br />
10 Security Engineering plc<br />
SI1233<br />
11 Security Engineering plc<br />
SI1241<br />
12 2 Security Engineering plc<br />
SI 1233 and SI 1241<br />
Sash Lock<br />
Emergency Nightlatch<br />
Mortice Deadlock<br />
Emergency Nightlatch<br />
and Mortice Deadlock<br />
Key via a Buga 4600 single<br />
cylinder or a Buga 4610 double<br />
cylinder<br />
Key via a Buga 4600 single<br />
cylinder<br />
Key via a Buga 4600 single<br />
cylinder or a Buga 4610 double<br />
cylinder<br />
Tw o separate keys via Buga<br />
4600 or Buga 4610 cylinders<br />
13 SI 1241 (tw o fitted) Mortice Deadlocks Key via a Buga 4600 single or<br />
Buga 4610 double cylinder<br />
Tw o keys<br />
or<br />
Tw o thumb-turns<br />
or<br />
One key and one thumb-turn<br />
Key plus lever handle<br />
or<br />
Key plus thumb-turn<br />
Assa Mico 944 panic latch<br />
or<br />
Briton 379 panic operator<br />
or<br />
Lever handle<br />
Key<br />
or<br />
Thumb-turn<br />
Combination of either:<br />
Assa Mico 944 panic latch,<br />
Briton 379 panic operator or<br />
Lever handle, and either:<br />
key or thumb-turn<br />
Tw o keys<br />
or<br />
Tw o thumb-turns<br />
or<br />
One key and one thumb-turn<br />
Notes:<br />
1. The Martin Roberts SD5001 also meets the requirements of PAS23-1:1999 and PAS24-1:1999. For further information, please refer<br />
to entries in <strong>section</strong>s on PAS23-1 and PAS24-1 relating to LPCB certificates 322b and 322c respectively.<br />
2. Although outside the scope of LPS1175: Issue 5, special consideration should be paid to the use of the Assa 9788 Mortice Deadlock<br />
in combination with the Assa 8761 Emergency Nightlatch or the SI1241 Mortice Deadlock in combination with the SI1233 Emergency<br />
Nightlatch. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a panic or emergency exit<br />
device unless the deadlock is automatically operated by the action of the panic or emergency device. For further information, please<br />
refer to the appropriate standards for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively.<br />
Certificate No: 322d to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product Name Doorset Configuration Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
SD5002-01<br />
Single plain leaf<br />
outward opening<br />
doorset<br />
SD5002-02 Double plain leaf<br />
outward opening<br />
doorset<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert. No.<br />
1.7 <strong>2.2</strong>5 0.7 1.2 2 322d/01<br />
1.9 <strong>2.2</strong>5 1.4 2.5 2 1 322d/02<br />
Compatible Locking Configurations<br />
20 Nov 2011 327
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Product Name<br />
Doorset Configuration<br />
Compatible Locking Systems<br />
SD5002-01<br />
SD5002-02<br />
Single plain leaf outw ard<br />
opening doorset<br />
Double plain leaf outw ard<br />
opening doorset<br />
Active Leaf<br />
Passive Leaf<br />
1 N/A<br />
2 3<br />
Compatible Locking Systems<br />
Compatible<br />
Locking Systems<br />
Manufacturer Model Type<br />
External<br />
Face<br />
1 Briton 5520 Sash lock Key and<br />
lever handle<br />
Compatible Operating<br />
Devices<br />
Internal<br />
Face<br />
Thumbturn<br />
and lever<br />
handle<br />
Compatible<br />
Cylinders<br />
CISA 52526-60-0<br />
double europrofile<br />
cylinder<br />
2 CISA 52526-60-0 and<br />
06453-05-0<br />
Mortice deadlock<br />
and sw ing bolts<br />
Key and<br />
lever handle<br />
Thumbturn<br />
and lever<br />
handle<br />
CISA 52526-60-0<br />
double europrofile<br />
cylinder<br />
3 Exidor HS923 Drop bolts N/A N/A N/A<br />
Note:<br />
1. In order to provide the certified level of resistance to forced entry, the key must be rotated through 720 degrees, to fully engage the<br />
bolts before removing it from the cylinder, and both drop bolts must be engaged. Security rating 1 classification prevails if the key is<br />
only turned once through 360 degrees before removing.<br />
Liddle Doors Limited<br />
Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom<br />
Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698<br />
E-mail: liddle@liddledoors.co.uk • Website: www.liddledoors.co.uk<br />
Certificate No: 442a to LPS 1175: Issue 5<br />
Hinged Security Doorsets<br />
Product<br />
Type<br />
Name<br />
Minimum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
LD Series 4<br />
Single leaf, outward opening hinged<br />
security doorset<br />
1.8 0.75 <strong>2.2</strong>5 1.15 4 442a/01<br />
Compatible Locking Devices<br />
LPCB Ref. Trade Type Lock Cylinder<br />
No. Name<br />
442a/01 LD Series 4 Single leaf hinged outw ard<br />
opening hinged security doorset<br />
Surelock McGill C3 3-w ay<br />
multiple bolting unit<br />
Abloy 5841 Europrofile single<br />
cylinder w ith internal thumbturn<br />
Certificate No: 442b to LPS 1175: Issue 6<br />
328 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Hinged Security Doorsets<br />
Product<br />
Type<br />
Name<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
Liddle Series<br />
3<br />
Single leaf outward opening<br />
hinged doorset<br />
Double leaf 1 outward opening<br />
hinged doorset<br />
1.8 <strong>2.2</strong> 0.75 1.2 3 442b/01<br />
1.8 <strong>2.2</strong> 1.4 2.0 3 442b/02<br />
Approved Locking Configurations<br />
Cert. No. Product Name Type Compatible Locking Systems<br />
442b/01 Liddle Series 3 Single leaf outw ard opening<br />
hinged doorset<br />
442b/02 Liddle Series 3 Double leaf outw ard opening<br />
hinged doorset<br />
Compatible Locking Systems<br />
Com patible<br />
Locking<br />
System<br />
Manufacturer Model Type<br />
1 Surelock McGill Stirling EX800<br />
ST105-0X-W3<br />
2 Surelock McGill Stirling EX800<br />
ST115-0X-<br />
K13O0PW3<br />
3 Surelock McGill Stirling DL800<br />
ST103-0X-W3<br />
4 Surelock McGill Stirling DL800<br />
ST113-0X-<br />
K13O0PW3<br />
Single point surface<br />
mounted emergency exit<br />
device<br />
Single point surface<br />
mounted emergency exit<br />
device w ith external<br />
access via a cylinder<br />
protected by an ‘SR3’<br />
cylinder guard<br />
Single point surface<br />
mounted deadlock<br />
Single point surface<br />
mounted deadlock w ith<br />
external access via a<br />
cylinder protected by an<br />
‘SR3’ cylinder guard<br />
Active leaf<br />
1, 2, 3, 4, 5, 6, 7, 8, 9, 10,<br />
11<br />
1, 2, 3, 4, 5, 6, 7, 8, 9, 10,<br />
11<br />
Compatible Operating<br />
Device<br />
Passive Leaf<br />
N/A<br />
12<br />
External Internal<br />
Face Face<br />
None Lever handle Not applicable<br />
Key plus lever<br />
handle<br />
None<br />
Key plus lever<br />
handle<br />
Lever handle<br />
Thumb turn<br />
plus lever<br />
handle<br />
Thumb turn<br />
plus lever<br />
handle<br />
Compatible<br />
Cylinders<br />
A, B, C, D, E<br />
Not applicable<br />
A, B, C, D, E<br />
20 Nov 2011 329
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
5 Surelock McGill Stirling AC800<br />
ST102-0X-W3<br />
6 Surelock McGill Stirling AC800<br />
ST122-0X-W3<br />
7 Surelock McGill Stirling AC800<br />
ST122-0X-<br />
K13O0PW3<br />
Single point surface<br />
mounted electromechanical<br />
access<br />
control lock pow ered by<br />
12 V, 24 V or 50 V failsecure<br />
solenoid 2 None Lever handle<br />
plus access<br />
control 2<br />
Single point surface<br />
mounted electromechanical<br />
access<br />
control lock pow ered by<br />
12 V, 24 V or 50 V failsecure<br />
solenoid 2<br />
Single point surface<br />
mounted electromechanical<br />
access<br />
control lock pow ered by<br />
12 V, 24 V or 50 V failsecure<br />
solenoid 2 w ith<br />
external key override via<br />
a cylinder protected by<br />
an ‘SR3’ cylinder guard<br />
Lever handle<br />
plus access<br />
control 2<br />
Lever handle<br />
plus either<br />
key or access<br />
control 2<br />
Lever handle<br />
plus access<br />
control 2<br />
Lever handle<br />
plus access<br />
control 2<br />
Not applicable<br />
Not applicable<br />
A, B, C, D, E<br />
8 Surelock McGill Stirling EX800<br />
ST105-0X-H3W3<br />
9 Surelock McGill Stirling EX800<br />
ST115-OX-<br />
H3K13O0PW3<br />
10 Surelock McGill Stirling AC800<br />
ST125-0X-H3W3<br />
11 Surelock McGill Stirling AC800<br />
ST125-0X-<br />
H3K13O0PW3<br />
12 Surelock McGill Surelock TA<br />
tow er bolt<br />
Compatible Cylinders<br />
Single point surface<br />
mounted emergency exit<br />
device<br />
Single point surface<br />
mounted emergency exit<br />
device w ith external<br />
access via a cylinder<br />
protected by an ‘SR3’<br />
cylinder guard<br />
Single point surface<br />
mounted electromechanical<br />
access<br />
control lock pow ered by<br />
12 V, 24 V or 50 V failsecure<br />
solenoid 2<br />
Single point surface<br />
mounted electromechanical<br />
access<br />
control lock pow ered by<br />
12 V, 24 V or 50 V failsecure<br />
solenoid 2 w ith<br />
external key override via<br />
a cylinder protected by<br />
an ‘SR3’ cylinder guard<br />
None Push pad Not applicable<br />
Key plus lever<br />
handle<br />
Lever handle<br />
plus access<br />
control 2<br />
Lever handle<br />
plus either<br />
key or access<br />
control 2<br />
Push pad<br />
Push pad<br />
plus access<br />
control 2<br />
Push pad<br />
plus access<br />
control 2<br />
A, B, C, D, E<br />
Not applicable<br />
A, B, C, D, E<br />
Tow er bolt 3 - - Not applicable<br />
Cylinder Reference Manufacturer Model Type<br />
A Abloy CY403 PT Rim cylinder<br />
B Abloy CY405 PT Rim cylinder<br />
C Assa 4857 Rim cylinder<br />
D Assa C5857 Rim cylinder<br />
E Kaba KV06.100 Rim cylinder<br />
Notes:<br />
1. The scope covers double doorsets formed with two leafs of equal widths.<br />
330 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
2. The resistance of the access control locks to ‘non-mechanical’ attack was not assessed as it is outside the scope of LPS1175.<br />
Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any<br />
access control equipment used to operate these locking systems. This is because the scope of access control devices and system<br />
configurations that may be used with these locking systems is ‘infinite’. It is therefore recommended that customer satisfy themselves<br />
that the components used are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected<br />
from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to<br />
disengage.<br />
3. Two tower bolts are fitted.<br />
Lowrey Contractors Limited<br />
200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom<br />
Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111<br />
E-mail: lowrey@talk21.com • Website: www.lowrey-contractors.co.uk<br />
Certificate No: 974d to LPS 1175: Issue 7<br />
Hinged Security Doorsets<br />
Product Name Product Type Minimum<br />
Height (m)<br />
Lowrey Level 4<br />
Single Leaf<br />
Security Doorset<br />
Lowrey Level 4<br />
Double Leaf<br />
Security Doorset<br />
Single leaf outward<br />
opening plain leaf<br />
doorset<br />
Double leaf<br />
outward opening<br />
plain leaf doorset<br />
Maximum Minimum Maximum Security Cert.<br />
Height (m) Width (m) Width (m) Rating No.<br />
1.0 2.4 0.6 1.3 4 974d/01<br />
1.0 2.4 1.2 2.6 4 974d/02<br />
Manufacturer Locking Device Type Cylinder Approved Product<br />
(LPCB Ref. No. 974d/..)<br />
Compatible Locking Devices 1, 2 1 2<br />
Abloy PL330/25 (V01) HP Padlock Abloy High Profile <br />
Abloy PL330/25 (V01) EX Padlock Abloy Exec <br />
Abloy PL330/25 (V01) PT Padlock Abloy Protec <br />
Abloy PL340/25 (V01) HP Padlock Abloy High Profile <br />
Abloy PL340/25 (V01) EX Padlock Abloy Exec <br />
Abloy PL340/25 (V01) PT Padlock Protec <br />
Abloy PL342 (V01) HP Padlock Abloy High Profile <br />
Abloy PL342 (V01) EX Padlock Abloy Exec <br />
Abloy PL342 (V01) PT Padlock Abloy Protec <br />
Abloy PL350/25 (V01) HP Padlock Abloy High Profile <br />
Abloy PL350/25 (V01) EX Padlock Abloy Exec <br />
Abloy PL350/25 (V01) PT Padlock Abloy Protec <br />
Kaba<br />
Kaba K18 w ith 11 mm open Padlock Kaba K20-C5 <br />
shackle (Item No. K180010-SS)<br />
Kaba Kaba K2010 Padlock Kaba K20 (Armoured) 3 <br />
Pickersgill-Kaye Kaye-Rota L8637-901 ST Padlock Kaba K20 (Armoured) 3 <br />
Pickersgill-Kaye Kaye-Rota L8637-902 SE Padlock Kaba K20 (Armoured) 3 <br />
Notes:<br />
1. Certification does not cover the use of locks other than those listed. Utilisation of unlisted locks may affect the level of security offered<br />
by the doorset.<br />
2. The ‘user friendliness’ of employing the padlocks listed has not been assessed as this is beyond the scope of LPS 1175: Issue 7.<br />
3. The torque resistant version of the Kaba K20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders.<br />
4. The Lowrey plain leaf doorsets are approved when installed in accordance with the instructions detailed on Lowrey document<br />
E-INST004 (Issue 8).<br />
20 Nov 2011 331
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Powershield Doors Limited<br />
21 Ferguson Drive, Knockmore Hill Industrial Park, Lisburn, Northern Ireland BT28 2EX, United Kingdom<br />
Tel: +44 (0)28 9266 2200 • Fax: +44 (0)28 9260 3600<br />
E-mail: sales@powershield.co.uk • Website: www.powershield.co.uk<br />
Certificate No: 852a to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product Name Type Minimum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
Powershield Class Single leaf, outward opening<br />
3 single<br />
Powershield Class<br />
3 double<br />
Powershield Class<br />
4 single<br />
Powershield Class<br />
4 double<br />
hinged security doorset<br />
Double leaf, outward<br />
opening hinged security<br />
Maximum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating 1<br />
Cert.<br />
No.<br />
1.8 2.4 0.75 1.2 3 852a/01<br />
1.8 2.4 1.4 2.4 3 852a/02<br />
Single leaf, outward opening 1.8 2.4 0.75 1.2 4 852a/03<br />
hinged security doorset<br />
Double leaf, outward 1.8 2.4 1.4 2.4 4 852a/04<br />
doorset 2<br />
opening hinged security<br />
Approved Locking Configurations<br />
LPCB Ref.<br />
No.<br />
852a/01 Powershield Class 3<br />
single<br />
Trade Name Type Compatible Locking Systems<br />
Single leaf, outward opening<br />
hinged security doorset<br />
Active Leaf<br />
Passive Leaf<br />
1 to 58 N/A<br />
852a/02 Powershield Class 3<br />
double<br />
Double leaf, outward opening<br />
hinged security doorset<br />
1 to 58 67<br />
852a/03 Powershield Class 4<br />
single<br />
Single leaf, outward opening<br />
hinged security doorset<br />
11, 13, 15, 17 , 40, 42, 44, 46<br />
59, 60, 61, 62, 63, 64, 65 and<br />
66<br />
N/A<br />
852a/04 Powershield Class 4<br />
double<br />
Double leaf, outward opening<br />
hinged security doorset<br />
11, 13, 15, 17 , 40, 42, 44, 46<br />
59, 60, 61, 62, 63, 64, 65 and<br />
66<br />
67<br />
Compatible Locking Systems<br />
Compatible<br />
Locking<br />
Systems<br />
Model 4 Type Operation<br />
Entry<br />
Exit<br />
External Cylinder<br />
1 MICO 942-3 /<br />
EURO ELK 3<br />
2 MICO 942-3P /<br />
EURO ELK 3<br />
3 MICO 942-3L /<br />
EURO ELK 3<br />
4 MICO 942-3<br />
EPC EM SEC /<br />
HSCH 3<br />
3-way panic exit<br />
device<br />
3-way emergency exit<br />
device<br />
3-way emergency exit<br />
device<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Key via EURO ELK 3 Panic exit push plate A, B, C, D, E and F<br />
Key via EURO ELK 3 Push pad A, B, C, D, E and F<br />
Key via EURO ELK 3 Lever handle A, B, C, D, E and F<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Europrofile cylinder<br />
within the HSCH3 cylinder<br />
guard and lever handle<br />
Internal access<br />
control and thumb<br />
turn override via<br />
Europrofile cylinder<br />
with push plate<br />
A, B, C, D, E and F<br />
332 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
5 MICO 942-3<br />
EPC EM SEC<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Access control and<br />
thumb turn override<br />
via Europrofile<br />
cylinder with push<br />
plate<br />
-<br />
6 MICO 942-3P<br />
EPC EM SEC /<br />
HSCH 3<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Europrofile cylinder<br />
within the HSCH3 cylinder<br />
guard and lever handle<br />
Access control and<br />
thumb turn override<br />
via Europrofile<br />
cylinder with push pad<br />
A, B, C, D, E and F<br />
7 MICO 942-3P<br />
EPC EM SEC<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Access control and<br />
thumb turn override<br />
via Europrofile<br />
cylinder with push pad<br />
-<br />
8 MICO 942-3L<br />
EPC EM SEC /<br />
HSCH 3<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Europrofile cylinder<br />
within the HSCH3 cylinder<br />
guard and lever handle<br />
Access control and<br />
thumb turn override<br />
via Europrofile<br />
cylinder with lever<br />
handle<br />
A, B, C, D, E and F<br />
9 MICO 942-3L<br />
EPC EM SEC<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Access control and<br />
thumb turn override<br />
via Europrofile<br />
cylinder with lever<br />
handle<br />
-<br />
10 MICO 942-3L<br />
EPC INT AD /<br />
HSCH 3<br />
3-way locking system<br />
with automatic<br />
deadlocking.<br />
Europrofile cylinder, within<br />
the HSCH 3 and lever<br />
handle<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and lever handle<br />
A, B, C, D, E and F<br />
11 MICO 942-3L<br />
EPC INT AD<br />
3-way locking system<br />
with automatic<br />
deadlocking.<br />
None<br />
Europrofile cylinder<br />
(Key or thumb<br />
turn)and lever handle<br />
-<br />
12 MICO 942-3<br />
EPC INT MD /<br />
HSCH 3<br />
3-way locking system Europrofile cylinder, within<br />
with manual deadlock. the HSCH 3 and lever<br />
handle<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and panic exit push<br />
plate<br />
A, B, C, D, E and F<br />
13 MICO 942-3<br />
EPC INT MD<br />
3-way locking system None<br />
with manual deadlock.<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and panic exit push<br />
plate<br />
-<br />
20 Nov 2011 333
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
14 MICO 942-3P<br />
EPC INT MD /<br />
HSCH 3<br />
15 MICO 942-3P<br />
EPC INT MD<br />
16 MICO 942-3L<br />
EPC INT MD /<br />
HSCH 3<br />
17 MICO 942-3L<br />
EPC INT MD<br />
18 MICO 942-3<br />
EPC SATE EM<br />
SEC / HSCH 3<br />
3-way locking system Europrofile cylinder, within<br />
with manual deadlock. the HSCH 3 and lever<br />
handle<br />
3-way locking system None<br />
with manual deadlock.<br />
3-way locking system Europrofile cylinder, within<br />
with manual deadlock. the HSCH 3 and lever<br />
handle<br />
3-way locking system None<br />
with manual deadlock.<br />
3-way panic exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Europrofile cylinder<br />
within the HSCH3 cylinder<br />
guard and lever handle<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and push pad<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and push pad<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and lever handle<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and lever handle<br />
Panic exit push plate<br />
A, B, C, D, E and F<br />
-<br />
A, B, C, D, E and F<br />
-<br />
A, B, C, D, E and F<br />
19 MICO 942-3<br />
EPC SATE EM<br />
SEC<br />
3-way panic exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Panic exit push plate -<br />
20 MICO 942-3P<br />
EPC SATE EM<br />
SEC / HSCH 3<br />
3-way emergency exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Europrofile cylinder<br />
within the HSCH3 cylinder<br />
guard and lever handle<br />
Push pad<br />
A, B, C, D, E and F<br />
21 MICO 942-3P<br />
EPC SATE EM<br />
SEC<br />
3-way emergency exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g. Push pad -<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
22 MICO 942-3L<br />
EPC SATE EM<br />
SEC / HSCH 3<br />
3-way emergency exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Europrofile cylinder<br />
within the HSCH3 cylinder<br />
guard and lever handle<br />
Lever handle<br />
A, B, C, D, E and F<br />
23 MICO 942-3L<br />
EPC SATE EM<br />
SEC<br />
3-way emergency exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Lever handle -<br />
24 MICO 942-3<br />
EPC SATE AD /<br />
HSCH 3<br />
3-way panic exit<br />
device with automatic<br />
deadlock.<br />
Europrofile cylinder, within<br />
the HSCH 3 and lever<br />
handle<br />
Panic exit push plate<br />
A, B, C, D, E and F<br />
334 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
25 MICO 942-3P<br />
EPC SATE AD /<br />
HSCH 3<br />
26 MICO 942-3L<br />
EPC SATE AD /<br />
HSCH 3<br />
3-way emergency exit<br />
device with automatic<br />
deadlock.<br />
3-way emergency exit<br />
device with automatic<br />
deadlock.<br />
27 MICO 942-3 3-way panic exit<br />
EPC SATE MD / device with manual<br />
HSCH 3 deadlock.<br />
28 MICO 942-3P 3-way emergency exit<br />
EPC SATE MD / device with manual<br />
HSCH 3 deadlock.<br />
29 MICO 942-3L 3-way emergency exit<br />
EPC SATE MD / device with manual<br />
HSCH 3 deadlock.<br />
30 MICO 942-3 /<br />
ELK 3<br />
31 MICO 942-3P /<br />
ELK 3<br />
32 MICO 942-3L /<br />
ELK 3<br />
33 MICO 942-3 EM<br />
SEC / HSCH 3<br />
3-way panic exit<br />
device<br />
3-way emergency exit<br />
device<br />
3-way emergency exit<br />
device<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Europrofile cylinder, within<br />
the HSCH 3 and lever<br />
handle<br />
Europrofile cylinder, within<br />
the HSCH 3 and lever<br />
handle<br />
Europrofile cylinder, within<br />
the HSCH 3 and lever<br />
handle<br />
Europrofile cylinder, within<br />
the HSCH 3 and lever<br />
handle<br />
Europrofile cylinder, within<br />
the HSCH 3 and lever<br />
handle<br />
Push pad<br />
Lever handle<br />
Panic exit push plate<br />
Push pad<br />
Lever handle<br />
A, B, C, D, E and F<br />
A, B, C, D, E and F<br />
A, B, C, D, E and F<br />
A, B, C, D, E and F<br />
A, B, C, D, E and F<br />
Key via ELK 3 Panic exit push plate K, L,M,N, O, P, Q, R<br />
and T<br />
Key via ELK 3 Push pad K, L,M,N, O, P, Q, R<br />
and T<br />
Key via ELK 3 Lever handle K, L,M,N, O, P, Q, R<br />
and T<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Scandinavian oval<br />
cylinder within the HSCH3<br />
cylinder guard and lever<br />
handle<br />
Internal access<br />
control and thumb<br />
turn override via<br />
Scandinavian oval<br />
cylinder with push<br />
plate<br />
G, H, I, J, K, L, M, N<br />
and P<br />
34 MICO 942-3 EM<br />
SEC<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Access control and<br />
thumb turn override<br />
via Scandinavian<br />
oval cylinder with<br />
push plate<br />
-<br />
35 MICO 942-3P<br />
EM SEC /<br />
HSCH 3<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Scandinavian oval<br />
cylinder within the HSCH3<br />
cylinder guard and lever<br />
handle<br />
Access control and<br />
thumb turn override<br />
via Scandinavian<br />
oval cylinder with<br />
push pad<br />
G, H, I, J, K, L, M, N<br />
and P<br />
36 MICO 942-3P<br />
EM SEC<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Access control and<br />
thumb turn override<br />
via Scandinavian<br />
oval cylinder with<br />
push pad<br />
-<br />
37 MICO 942-3L<br />
EM SEC /<br />
HSCH 3<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Scandinavian oval<br />
cylinder within the HSCH3<br />
cylinder guard and lever<br />
handle<br />
Access control and<br />
thumb turn override<br />
via Scandinavian oval<br />
cylinder with lever<br />
handle<br />
G, H, I, J, K, L, M, N<br />
and P<br />
20 Nov 2011 335
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
38 MICO 942-3L<br />
EM SEC<br />
3-way locking system<br />
with solenoid<br />
deadlock and<br />
electromechanical<br />
access control<br />
powdered by 12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Access control and<br />
thumb turn override<br />
via Scandinavian oval<br />
cylinder with lever<br />
handle<br />
-<br />
39 MICO 942-3L<br />
INT AD / HSCH<br />
3<br />
40 MICO 942-3L<br />
INT AD<br />
41 MICO 942-3 INT<br />
MD / HSCH 3<br />
3-way locking system<br />
with automatic<br />
deadlocking.<br />
3-way locking system<br />
with automatic<br />
deadlocking.<br />
Scandinavian oval cylinder,<br />
within the HSCH 3 and<br />
lever handle<br />
None<br />
3-way locking system Scandinavian oval cylinder,<br />
with manual deadlock. within the HSCH 3 and<br />
lever handle<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and lever<br />
handle<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn)and lever<br />
handle<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and panic<br />
exit push plate<br />
G, H, I, J, K, L, M, N<br />
and P<br />
-<br />
G, H, I, J, K, L, M, N<br />
and P<br />
42 MICO 942-3 INT<br />
MD<br />
3-way locking system None<br />
with manual deadlock.<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and panic<br />
exit push plate<br />
-<br />
43 MICO 942-3P<br />
INT MD / HSCH<br />
3<br />
44 MICO 942-3P<br />
INT MD<br />
45 MICO 942-3L<br />
INT MD / HSCH<br />
3<br />
46 MICO 942-3L<br />
INT MD<br />
3-way locking system Scandinavian oval cylinder,<br />
with manual deadlock. within the HSCH 3 and<br />
lever handle<br />
3-way locking system None<br />
with manual deadlock.<br />
3-way locking system Scandinavian oval cylinder,<br />
with manual deadlock. within the HSCH 3 and<br />
lever handle<br />
3-way locking system None<br />
with manual deadlock.<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and push<br />
pad<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and push<br />
pad<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and lever<br />
handle<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and lever<br />
handle<br />
G, H, I, J, K, L, M, N<br />
and P<br />
-<br />
G, H, I, J, K, L, M, N<br />
and P<br />
-<br />
336 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
47 MICO 942-3 3-way panic exit<br />
SATE EM SEC / device with solenoid<br />
HSCH 3 deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Scandinavian oval<br />
cylinder within the HSCH3<br />
cylinder guard and lever<br />
handle<br />
Panic exit push plate<br />
G, H, I, J, K, L, M, N<br />
and P<br />
48 MICO 942-3<br />
SATE EM SEC<br />
3-way panic exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Panic exit push plate -<br />
49 MICO 942-3P<br />
SATE EM SEC /<br />
HSCH 3<br />
3-way emergency exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Scandinavian oval<br />
cylinder within the HSCH3<br />
cylinder guard and lever<br />
handle<br />
Push pad<br />
G, H, I, J, K, L, M, N<br />
and P<br />
50 MICO 942-3P<br />
SATE EM SEC<br />
3-way emergency exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Push pad -<br />
51 MICO 942-3L<br />
SATE EM SEC /<br />
HSCH 3<br />
3-way emergency exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 or key override<br />
via Scandinavian oval<br />
cylinder within the HSCH3<br />
cylinder guard and lever<br />
handle<br />
Lever handle<br />
G, H, I, J, K, L, M, N<br />
and P<br />
52 MICO 942-3L<br />
SATE EM SEC<br />
3-way emergency exit<br />
device with solenoid<br />
deadlock and electromechanical<br />
access<br />
control powered by<br />
12v.<br />
Access control system (e.g.<br />
key pad or swipe card) not<br />
specified 3 and lever handle<br />
Lever handle -<br />
20 Nov 2011 337
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
53 MICO 942-3<br />
SATE AD /<br />
HSCH 3<br />
3-way panic exit<br />
device with automatic<br />
deadlock.<br />
Scandinavian oval cylinder,<br />
within the HSCH 3 and<br />
lever handle<br />
Panic exit push plate<br />
G, H, I, J, K, L, M, N<br />
and P<br />
54 MICO 942-3P<br />
SATE AD /<br />
HSCH 3<br />
3-way emergency exit<br />
device with automatic<br />
deadlock.<br />
Scandinavian oval cylinder,<br />
within the HSCH 3 and<br />
lever handle<br />
Push pad<br />
G, H, I, J, K, L, M, N<br />
and P<br />
55 MICO 942-3L<br />
SATE AD /<br />
HSCH 3<br />
3-way emergency exit<br />
device with automatic<br />
deadlock.<br />
Scandinavian oval cylinder,<br />
within the HSCH 3 and<br />
lever handle<br />
Lever handle<br />
G, H, I, J, K, L, M, N<br />
and P<br />
56 MICO 942-3<br />
SATE MD /<br />
HSCH 3<br />
3-way panic exit<br />
device with manual<br />
deadlock.<br />
Scandinavian oval cylinder,<br />
within the HSCH 3 and<br />
lever handle<br />
Panic exit push plate<br />
G, H, I, J, K, L, M, N<br />
and P<br />
57 MICO 942-3P<br />
SATE MD /<br />
HSCH 3<br />
3-way emergency exit<br />
device with manual<br />
deadlock.<br />
Scandinavian oval cylinder,<br />
within the HSCH 3 and<br />
lever handle<br />
Push pad<br />
G, H, I, J, K, L, M, N<br />
and P<br />
58 MICO 942-3L<br />
SATE MD /<br />
HSCH 3<br />
3-way emergency exit<br />
device with manual<br />
deadlock.<br />
Scandinavian oval cylinder,<br />
within the HSCH 3 and<br />
lever handle<br />
Lever handle<br />
G, H, I, J, K, L, M, N<br />
and P<br />
59 MICO 942-3L<br />
EPC INT AD /<br />
HSCH 4<br />
3-way locking system<br />
with automatic<br />
deadlocking.<br />
Europrofile cylinder within<br />
the HSCH 4 and lever<br />
handle<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and lever handle<br />
A, B, C, D, E and F<br />
60 MICO 942-3<br />
EPC INT MD /<br />
HSCH 4<br />
61 MICO 942-3P<br />
EPC INT MD /<br />
HSCH 4<br />
62 MICO 942-3L<br />
EPC INT MD /<br />
HSCH 4<br />
63 MICO 942-3L<br />
INT AD / HSCH<br />
4<br />
64 MICO 942-3 INT<br />
MD / HSCH 4<br />
3-way locking system Europrofile cylinder within<br />
with manual deadlock. the HSCH 4 and lever<br />
handle<br />
3-way locking system Europrofile cylinder within<br />
with manual deadlock. the HSCH 4 and lever<br />
handle<br />
3-way locking system Europrofile cylinder within<br />
with manual deadlock. the HSCH 4 and lever<br />
handle<br />
3-way locking system<br />
with automatic<br />
deadlocking.<br />
Scandinavian oval cylinder<br />
within the HSCH 4 and<br />
lever handle<br />
3-way locking system Scandinavian oval cylinder<br />
with manual deadlock. within the HSCH 4 and<br />
lever handle<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and panic exit push<br />
plate<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and push pad<br />
Europrofile cylinder<br />
(Key or thumb turn)<br />
and lever handle<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and lever<br />
handle<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and panic<br />
exit push plate<br />
A, B, C, D, E and F<br />
A, B, C, D, E and F<br />
A, B, C, D, E and F<br />
G, H, I, J, K, L, M, N<br />
and P<br />
G, H, I, J, K, L, M, N<br />
and P<br />
65 MICO 942-3P<br />
INT MD / HSCH<br />
4<br />
66 MICO 942-3L<br />
INT MD / HSCH<br />
4<br />
67 M0455 Surface mounted<br />
barrel bolts<br />
Compatible Cylinders<br />
3-way locking system Scandinavian oval cylinder<br />
with manual deadlock. within the HSCH 4 and<br />
lever handle<br />
3-way locking system Scandinavian oval cylinder<br />
with manual deadlock. within the HSCH 4 and<br />
lever handle<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and push<br />
pad<br />
Scandinavian oval<br />
cylinder (Key or<br />
thumb turn) and lever<br />
handle<br />
G, H, I, J, K, L, M, N<br />
and P<br />
G, H, I, J, K, L, M, N<br />
and P<br />
- - -<br />
338 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Cylinder Reference Manufacturer Model Type<br />
A Abloy Protec CY304 Double Europrofile cylinder (Key:Key or Key:Thumbturn)<br />
B Abloy Disclock Pro CY304 Double Europrofile cylinder (Key:Key or Key:Thumbturn)<br />
C ASSA Twin 7622 Double Europrofile cylinder (Key:Key or Key:Thumbturn)<br />
D ASSA C5822 Double Europrofile cylinder (Key:Key or Key:Thumbturn)<br />
E ASSA 4822 Double Europrofile cylinder (Key:Key or Key:Thumbturn)<br />
F Kaba Quattro S Euro Double Europrofile cylinder (Key:Key or Key:Thumbturn)<br />
G ASSA 4807 Half Scandinavian oval mechanical cylinder<br />
H ASSA Twin 7607 Half Scandinavian oval mechanical cylinder<br />
I ASSA C5807 Half Scandinavian oval mechanical cylinder<br />
J ASSA 4407 Half Scandinavian oval mechanical cylinder<br />
K Abloy Protec CY201PT Half Scandinavian oval mechanical cylinder<br />
L Locken CL-PL2WR Half Scandinavian oval mechatronic cylinder<br />
M Kaba Quattro S Oval Half Scandinavian oval mechanical cylinder<br />
N Kaba K20 Oval Half Scandinavian oval mechanical cylinder<br />
O Abloy Disclock Pro CY201DPHalf Scandinavian oval mechanical cylinder<br />
P ASSA 4801 Half Scandinavian oval mechanical cylinder<br />
Q ASSA Twin 7601 Half Scandinavian oval mechanical cylinder<br />
R ASSA C5801 Half Scandinavian oval mechanical cylinder<br />
T ASSA 4401 Half Scandinavian oval mechanical cylinder<br />
Notes:<br />
1. This security rating prevails when the doorsets are locked in the optimum locked condition. The following locking configurations<br />
incorporate a manual deadlock mechanism: 13, 15, 17, 42, 44 and 46. If the door is closed and the deadlock mechanism is not<br />
engaged then a minimum locked condition exists. In this condition the doorsets achieve a minimum of a Security Rating 1.<br />
2. The scope of this approval covers double leaf doorsets with equal leafs. Double doorsets with unequal leafs are not covered by this<br />
approval.<br />
3. The resistance of the access control locks to “non-mechanical” attack is not covered by this approval as they were outside the scope<br />
of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and<br />
performance of any access control equipment that may be used to operate these locking systems. This is because the scope of<br />
access control devices and system configurations that may be used with these locking systems is “infinite”. It is therefore<br />
recommended that specifiers’ satisfy themselves that the components used are either resistant to mechanical and other forms of<br />
tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental<br />
conditions/interference that may cause the locking system to disengage.<br />
4. Although outside the scope of LPS 1175: Issue 6, special consideration should be paid to the use of locking systems with separate<br />
deadlocks, e.g. Mico 942-3 INT MD. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a<br />
panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or exit device. Furthermore,<br />
double doorsets with panic devices fitted to only one leaf do not necessarily suit public areas. For further information, please refer to<br />
the appropriate standards for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively.<br />
PSF Wales Limited<br />
Llys Rhiannon, Cil Yr Ychen Industrial Estate, Landeilo Road, Llandybie, Ammanford, Carmarthenshire SA18<br />
3GY, United Kingdom<br />
Tel: +44 (0)1269 851777 • Fax: +44 (0)1269 851747<br />
E-mail: sales@psfwales.co.uk • Website: www.psfwales.co.uk<br />
Certificate No: 953a to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product<br />
Type<br />
Name<br />
Hercules Single leaf outward opening<br />
SAF 3<br />
hinged doorset<br />
Double leaf outward opening<br />
hinged doorset<br />
Hercules Single leaf outward opening<br />
SAF 4<br />
hinged doorset<br />
Double leaf outward opening<br />
hinged doorset<br />
Structural Opening<br />
Height (m)<br />
Structural Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
2.12 1.12 3 953a/01<br />
<strong>2.2</strong>1 <strong>2.2</strong>1 3 1 953a/02<br />
2.12 1.12 4 953a/03<br />
<strong>2.2</strong>1 <strong>2.2</strong>1 4 1 953a/04<br />
20 Nov 2011 339
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Approved Locking Configurations<br />
LPCB Ref. No.<br />
Product Name Type Compatible Locking Systems<br />
953a/01 Hercules SAF 3 Single leaf outw ard opening<br />
hinged doorset<br />
953a/02 Hercules SAF 3 Double leaf outw ard opening<br />
hinged doorset<br />
953a/03 Hercules SAF 4 Single leaf outw ard opening<br />
hinged doorset<br />
953a/04 Hercules SAF 4 Double leaf outw ard opening<br />
hinged doorset<br />
Compatible Locking Systems<br />
Compatible<br />
Locking<br />
System<br />
Active Leaf<br />
Passive Leaf<br />
1 and 2 N/A<br />
1 and 2 3<br />
1 and 2 N/A<br />
1 and 2 3<br />
Manufacturer Model / Type External Face Internal Face Compatible<br />
Cylinders<br />
1 Tindall<br />
Engineering<br />
2 Tindall<br />
Engineering<br />
3 Commercial<br />
Body Fittings<br />
Limited<br />
Compatible Cylinders<br />
Mico 942-3L INT AD / USCH4<br />
three-point auto-deadlocking<br />
auto-bolting system w ith<br />
external cylinder access<br />
Mico 942-3L INT MD / USCH4<br />
three-point manual-deadlocking<br />
auto-bolting system w ith<br />
external cylinder access<br />
USCH4 cylinder<br />
guard incorporating a<br />
Scandinavian oval<br />
cylinder<br />
USCH4 cylinder<br />
guard incorporating a<br />
Scandinavian oval<br />
cylinder<br />
Thumbturn and lever<br />
handle<br />
Thumbturn and lever<br />
handle<br />
Sprung tow er bolt - Tw o sprung tow er<br />
bolts<br />
Cylinder Manufacturer Model Type<br />
Reference<br />
A Abloy Disclock Pro CY201DP Mechanical Scandinavian oval cylinder<br />
B Assa 4807 Mechanical Scandinavian oval cylinder<br />
C Assa C5807 Mechanical Scandinavian oval cylinder<br />
D Assa Tw in 7607 Mechanical Scandinavian oval cylinder<br />
E Kaba K20 Oval Mechanical Scandinavian oval cylinder<br />
F Kaba Quattro S Oval Mechanical Scandinavian oval cylinder<br />
G Locken CL-PL2WR Mechatronic Scandinavian oval cylinder 2<br />
Notes:<br />
1. This rating is achieved with both bolts engaged on the passive leaf engaged and the lock mechanism fitted to the primary leaf<br />
engaged and deadlocked. The doorset achieves at least Security Rating 1 if one of the bolts on the passive leaf is not engaged.<br />
2. The resistance of the electronic cylinder to “non-mechanical” attack has not been assessed as it is outside the scope of LPS1175.<br />
Likewise, the assessment has not covered possible effects of any susceptibilities relating to the functionality and performance of the<br />
keys that may be used to operate the cylinder. It is therefore recommended that specifiers and installers satisfy themselves that the<br />
components used are either resistant to mechanical and other forms of tampering/abuse and are resistant to any environmental<br />
conditions/interference that may cause the lock to disengage.<br />
A to G<br />
A to G<br />
N/A<br />
R & D Sheetmetal Limited<br />
Unit 1A, Victoria Court, Colliers Way, Clayton West, Huddersfield, West Yorkshire HD8 9TR, United Kingdom<br />
Tel: +44 (0)1484 864886 • Fax: +44 (0)1484 866505<br />
E-mail: sales@randdsheetmetal.co.uk • Website: www.randdsheetmetal.co.uk<br />
Certificate No: 1034b to LPS 1175: Issue 7<br />
340 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Hinged Security Doorset<br />
Product Product Type<br />
Name<br />
Security Single leaf outward<br />
Evo IV opening hinged security<br />
Security<br />
Evo V<br />
Security<br />
Evo VI<br />
doorset<br />
Single leaf outward<br />
opening hinged security<br />
doorset<br />
Single leaf outward<br />
opening hinged security<br />
doorset<br />
Minimum<br />
Height (m)<br />
Maximum<br />
Height (m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Security<br />
Rating<br />
Cert. No.<br />
1.8 2.3 0.8 1.1 4 1034b/01<br />
1.8 2.3 0.8 1.1 5 1034b/02<br />
1.8 2.3 0.8 1.1 6 1034b/03<br />
Compatible Locking Configurations<br />
Product Name Doorset Configuration<br />
Compatible Locking Systems<br />
Security Evo IV Single leaf outw ard opening hinged security doorset 1 to 15<br />
Security Evo V Single leaf outw ard opening hinged security doorset 16 to 30<br />
Security Evo VI Single leaf outw ard opening hinged security doorset 31 to 45<br />
Compatible Locking Systems<br />
Compatible<br />
Locking<br />
System<br />
Manufacturer Model Type Compatible Operating<br />
Devices<br />
External<br />
Face<br />
Internal<br />
Face<br />
Abryll AD3 Single point locking Key and Thumb turn<br />
/USCH 4 system w ith automatic lever handle and lever<br />
Limited<br />
deadlocking<br />
handle<br />
Abryll MD2<br />
Key and<br />
/USCH 4<br />
lever handle<br />
1 Tindall<br />
Engineering<br />
2 Tindall<br />
Engineering<br />
Limited<br />
3 Tindall<br />
Engineering<br />
Limited<br />
4 Tindall<br />
Engineering<br />
Limited<br />
5 Tindall<br />
Engineering<br />
Limited<br />
Abryll MD1<br />
/USCH 4<br />
Abryll MD3<br />
/USCH 4<br />
Abryll EPC<br />
MD2 /USCH 4<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
Compatible Cylinders<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
20 Nov 2011 341
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
6 Tindall<br />
Engineering<br />
Limited<br />
7 Tindall<br />
Engineering<br />
Limited<br />
8 Tindall<br />
Engineering<br />
Limited<br />
9 Tindall<br />
Engineering<br />
Limited<br />
10 Tindall<br />
Engineering<br />
Limited<br />
11 Tindall<br />
Engineering<br />
Limited<br />
12 Tindall<br />
Engineering<br />
Limited<br />
13 Tindall<br />
Engineering<br />
Limited<br />
14 Tindall<br />
Engineering<br />
Limited<br />
15 Tindall<br />
Engineering<br />
Limited<br />
16 Tindall<br />
Engineering<br />
Limited<br />
17 Tindall<br />
Engineering<br />
Limited<br />
18 Tindall<br />
Engineering<br />
Limited<br />
19 Tindall<br />
Engineering<br />
Limited<br />
20 Tindall<br />
Engineering<br />
Limited<br />
Abryll EPC<br />
MD1 /USCH 4<br />
Abryll EPC<br />
MD3 /USCH 4<br />
Mico EVO 3<br />
AD3 /USCH 4<br />
Mico EVO 3<br />
MD2 /USCH 4<br />
Mico EVO 3<br />
MD1 /USCH 4<br />
Mico EVO 3<br />
MD3 /USCH 4<br />
Mico EVO 3<br />
AD3 EPC<br />
/USCH 4<br />
Mico EVO 3<br />
MD2 EPC<br />
/USCH 4<br />
Mico EVO 3<br />
MD1<br />
EPC/USCH 4<br />
Mico EVO 3<br />
MD3<br />
EPC/USCH 4<br />
Abryll AD3<br />
/USCH 5<br />
Abryll MD2<br />
/USCH 5<br />
Abryll MD1<br />
/USCH 5<br />
Abryll MD3<br />
/USCH 5<br />
Abryll EPC<br />
MD2 /USCH 5<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
Single point locking<br />
system w ith automatic<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
342 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
21 Tindall<br />
Engineering<br />
Limited<br />
22 Tindall<br />
Engineering<br />
Limited<br />
23 Tindall<br />
Engineering<br />
Limited<br />
24 Tindall<br />
Engineering<br />
Limited<br />
25 Tindall<br />
Engineering<br />
Limited<br />
26 Tindall<br />
Engineering<br />
Limited<br />
27 Tindall<br />
Engineering<br />
Limited<br />
28 Tindall<br />
Engineering<br />
Limited<br />
29 Tindall<br />
Engineering<br />
Limited<br />
30 Tindall<br />
Engineering<br />
Limited<br />
31 Tindall<br />
Engineering<br />
Limited<br />
32 Tindall<br />
Engineering<br />
Limited<br />
33 Tindall<br />
Engineering<br />
Limited<br />
34 Tindall<br />
Engineering<br />
Limited<br />
35 Tindall<br />
Engineering<br />
Limited<br />
Abryll EPC<br />
MD1 /USCH 5<br />
Abryll EPC<br />
MD3 /USCH 5<br />
Mico EVO 3<br />
AD3 /USCH 5<br />
Mico EVO 3<br />
MD2 /USCH 5<br />
Mico EVO 3<br />
MD1 /USCH 5<br />
Mico EVO<br />
MD3 /USCH 5<br />
Mico EVO 3<br />
AD3 EPC<br />
/USCH 5<br />
Mico EVO3<br />
MD2 EPC<br />
/USCH 5<br />
Mico EVO 3<br />
MD1 EPC<br />
/USCH 5<br />
Mico EVO 3<br />
MD3 EPC<br />
/USCH 5<br />
Abryll AD3<br />
/USCH 6<br />
Abryll MD2<br />
/USCH 6<br />
Abryll MD1<br />
/USCH 6<br />
Abryll MD3<br />
/USCH 6<br />
Abryll EPC<br />
MD2 /USCH 6<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
Single point locking<br />
system w ith automatic<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
20 Nov 2011 343
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
36 Tindall<br />
Engineering<br />
Limited<br />
37 Tindall<br />
Engineering<br />
Limited<br />
38 Tindall<br />
Engineering<br />
Limited<br />
39 Tindall<br />
Engineering<br />
Limited<br />
40 Tindall<br />
Engineering<br />
Limited<br />
41 Tindall<br />
Engineering<br />
Limited<br />
42 Tindall<br />
Engineering<br />
Limited<br />
43 Tindall<br />
Engineering<br />
Limited<br />
44 Tindall<br />
Engineering<br />
Limited<br />
45 Tindall<br />
Engineering<br />
Limited<br />
Abryll EPC<br />
MD1 /USCH 6<br />
Abryll EPC<br />
MD3 /USCH 6<br />
Mico EVO 3<br />
AD3 /USCH 6<br />
Mico EVO 3<br />
MD2 /USCH 6<br />
Mico EVO 3<br />
MD1 /USCH 6<br />
Mico EVO 3<br />
MD3 /USCH 6<br />
Mico EVO 3<br />
AD3 EPC<br />
/USCH 6<br />
Mico EVO 3<br />
MD2 EPC<br />
/USCH 6<br />
Mico EVO 3<br />
MD1 EPC<br />
/USCH 6<br />
Mico EVO 3<br />
MD3 EPC<br />
/USCH 6<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
Single point locking<br />
system w ith manual<br />
deadlocking<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
3-w ay locking system<br />
w ith manual deadlocking<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key and<br />
lever handle<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
Key or<br />
thumb turn<br />
and push<br />
plate<br />
Key or<br />
thumb turn<br />
and push<br />
pad<br />
Key or<br />
thumb turn<br />
and lever<br />
handle<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
A, B, C, D, E, F, G, H, I, J, K,<br />
L, M, N, O, P, Q, Al, AM, AN,<br />
AO, AP, AQ and AR<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
R, S, T, U, V, W, X, Y, Z, AA,<br />
AB, AC, AD, AE, AF, AG,<br />
AH, AI and AK<br />
Compatible Cylinders<br />
Cylinder Manufacturer Model Type<br />
Reference<br />
A Abloy Protec CY201 PT Scandinavian Oval<br />
B Abloy Protec Cliq CY201 Scandinavian Oval<br />
C AMS CL-OVLD Scandinavian Oval<br />
D ASSA 4401dp Scandinavian Oval<br />
E ASSA 4401 Cliq Scandinavian Oval<br />
F ASSA 4407dp Scandinavian Oval<br />
G ASSA 4407 Cliq Scandinavian Oval<br />
H ASSA 4801 Scandinavian Oval<br />
I ASSA 4807 Scandinavian Oval<br />
344 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
J ASSA C5801 Scandinavian Oval<br />
K ASSA C5807 Scandinavian Oval<br />
L ASSA Tw in 7601 Scandinavian Oval<br />
M ASSA Tw in 7607 Scandinavian Oval<br />
N Kaba K20 Scandinavian Oval<br />
O Kaba Quattro PluS Scandinavian Oval<br />
P Locken CL-PL2WR Scandinavian Oval<br />
Q Medeco M3-ARX Scandinavian Oval<br />
R Abloy Protec CY304 Europrofile double cylinder (key:key)<br />
S Abloy Protec Cliq CY333 Europrofile double cylinder (key:thumbturn)<br />
T Abloy Protec CY333 Europrofile double cylinder (key:thumbturn)<br />
U Abloy Protec Cliq CY304 Europrofile double cylinder (key:key)<br />
V Abloy Protec CY305 Europrofile double cylinder (key:thumbturn)<br />
W Abloy Protec Cliq CY305 Europrofile double cylinder (key:thumbturn)<br />
X ASSA 4422dp Europrofile double cylinder (key:key)<br />
Y ASSA 4427dp Europrofile double cylinder (key:thumbturn)<br />
Z ASSA 44M22 Cliq Europrofile double cylinder (key:key)<br />
AA ASSA 44M27 Cliq Europrofile double cylinder (key:thumbturn)<br />
AB ASSA 4822 Europrofile double cylinder (key:key)<br />
AC ASSA 4827 Europrofile double cylinder (key:thumbturn)<br />
AD ASSA C5822 Europrofile double cylinder (key:key)<br />
AE ASSA C5827 Europrofile double cylinder (key:thumbturn)<br />
AF ASSA 7622 Europrofile double cylinder (key:key)<br />
AG ASSA 7627 Europrofile double cylinder (key:thumbturn)<br />
AH Kaba Quattro PluS Europrofile double cylinder (key:key)<br />
AI Kaba Quattro PluS Europrofile double cylinder (key:thumbturn)<br />
AJ Medeco M3-ARX Europrofile double cylinder (key:key)<br />
AK Medeco M3-ARX Europrofile double cylinder (key:thumbturn)<br />
AL Abloy Protec CY403 Rim<br />
AM Abloy Protec Cliq CY403 Rim<br />
AN Kaba Quatro Plus Rim<br />
AO Medeco M3-ARX Rim<br />
AP AMS CL-CA2D Finish Round<br />
AQ ASSA 4857 Round threaded<br />
AR ASSA C5857 Round threaded<br />
Notes:<br />
1. Certification does not cover the use of locks other than those listed above. Utilisation of unlisted locks may affect the level of security<br />
offered by the doorset.<br />
2. The doorset’s resistance relies on the supporting substrate offering compatible resistance to manual attack.<br />
3. The Security Evo IV doorset is approved when installed in accordance with the instructions detailed on document EVO-INST-02<br />
(Issue 1).<br />
4. The Security Evo V and VI doorsets are approved when installed in accordance with the instructions detailed on document EVO-<br />
INST-01 (Issue 3) into the Security Evo enclosures only.<br />
20 Nov 2011 345
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Safe Partnership<br />
3 East Street, Wareham, Dorset BH20 4NN, United Kingdom<br />
Tel: +44 (0)1929 551100 • Fax: +44 (0)1929 553300<br />
E-mail: safe@safe<strong>part</strong>nership.org • Website: www.safe<strong>part</strong>nership.co.uk<br />
Certificate No: 835a to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product Name Type Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Safe Doorset SR1 Single leaf<br />
outward<br />
opening<br />
hinged security<br />
timber doorset<br />
Safe Doorset SR2 Single leaf<br />
outward<br />
opening<br />
hinged security<br />
timber doorset<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert. No.<br />
1.8 2 0.675 0.825 2 835a/01<br />
1.8 2 0.675 0.825 2 1 835a/02<br />
Compatible Locking Devices<br />
Lock<br />
Position<br />
Upper<br />
Middle<br />
Low er<br />
Lockset Cylinder Associated<br />
Ironmongery<br />
ERA mortice deadlock<br />
(Product code 325-31)<br />
ERA Euro Pro Fit<br />
sashlock (Product code<br />
326-31)<br />
ERA Fortress 5 lever<br />
mortice sashlock<br />
(Product code 362-31)<br />
ERA mortice deadlock<br />
(Product code 325-31)<br />
ERA Satin 35/35 mm<br />
key/thumbturn europrofile<br />
double cylinder (Product<br />
code 4103-51)<br />
ERA Satin 35/35 mm<br />
key/thumbturn europrofile<br />
double cylinder (Product<br />
code 4103-51)<br />
ERA Satin 35/35 mm<br />
key/thumbturn europrofile<br />
double cylinder (Product<br />
code 4103-51)<br />
-<br />
Solon Satin Escutcheons<br />
(Product code 263 55<br />
ESC)<br />
Solon Satin sash lever<br />
handle fitted to each face<br />
(Product code BD0406)<br />
Solon Satin sash lever<br />
handle fitted to each face<br />
(Product code 222-00)<br />
Solon Satin Escutcheons<br />
(Product code 263 55<br />
ESC)<br />
Doorset<br />
SR1 SR2<br />
<br />
<br />
<br />
<br />
Note:<br />
1. This doorset achieves it’s Security Rating when all three locks are engaged. The doorset achieves Security Rating 1 when only one<br />
lock is engaged.<br />
SafeGuard Doors, A Division of Adams Rite Europe Limited<br />
School Street, Willenhall, West Midlands WV13 3PW, United Kingdom<br />
Tel: +44 (0))1902 364601 • Fax: +44 (0)1902 364602<br />
E-mail: sales@safeguarddoors.co.uk • Website: www.safeguarddoors.co.uk<br />
Certificate No: 661a to LPS 1175: Issue 5<br />
346 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Hinged Security Doorsets<br />
Product<br />
Type<br />
Name<br />
Trenchard<br />
Fenwick<br />
Single leaf, outward opening<br />
hinged security doorset<br />
Single leaf, outward opening<br />
hinged security doorset<br />
Minimum<br />
Clear<br />
Opening<br />
Height (m)<br />
Maximum<br />
Clear<br />
Opening<br />
Height (m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width (m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.8 2.4 0.76 1.2 3 661a/01<br />
1.8 2.4 0.76 1.2 4 661a/02<br />
Compatible Locking Systems<br />
LPCB<br />
Ref. No.<br />
Trade<br />
Name<br />
Com patible Locking Systems<br />
Manufacturer Model Type Compatible Cylinders<br />
661a/01 Trenchard Surelock McGill EX210(B1) -L1 Three point surface<br />
mounted locking system<br />
fitted w ith push bar and<br />
LEO external operating<br />
device<br />
661a/02 Fenw ick Surelock McGill EX210(B1) Three point surface<br />
mounted locking system<br />
fitted w ith push bar<br />
Bramah C17SI<br />
DOM 419ix10G<br />
Kaba KV207.0000C5-SC<br />
Union 26X11B<br />
Yale PK1133 Pro-Key<br />
N/A<br />
Stafford Bridge Doors Limited<br />
Bedford Road, Pavenham, Bedford MK43 7PS, United Kingdom<br />
Tel: +44 (0)1234 826316 • Fax: +44 (0)1234 826319<br />
E-mail: sales@sbdoors.com • Website: www.surelockmcgillgroup.com/sbd<br />
Certificate No: 516a to LPS 1175: Issue 5<br />
Hinged Security Doorsets<br />
Product<br />
Type<br />
Name<br />
Sandhurst<br />
Wilton<br />
Halton<br />
Sandhurst<br />
Wilton<br />
Halton<br />
Single leaf, outward and<br />
inward opening hinged<br />
security doorset<br />
Single leaf, outward<br />
opening hinged security<br />
doorset<br />
Single leaf, outward<br />
opening hinged security<br />
doorset<br />
Double leaf, outward<br />
opening hinged security<br />
doorset<br />
Double leaf, outward<br />
opening hinged security<br />
doorset<br />
Double leaf, outward<br />
opening hinged security<br />
doorset<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.9 2.5 0.7 1.4 3 516a/01<br />
1.9 2.5 0.7 1.4 4 516a/03<br />
1.468 2.5 0.7 1.4 4 516a/04<br />
1.9 2.5 1.4 3.0 3 516a/05<br />
1.9 2.5 1.4 3.0 4 516a/06<br />
1.9 2.5 1.4 3.0 4 516a/07<br />
Compatible Locking Systems<br />
20 Nov 2011 347
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
LPCB Ref.<br />
No.<br />
Trade<br />
Name<br />
516a/01 Sandhurst<br />
Type<br />
Single leaf outw ard<br />
opening doorset<br />
Nom inal<br />
Compatible Locking Systems<br />
Leaf<br />
Thickness<br />
Active Leaf<br />
Passive Leaf<br />
(mm)<br />
46 AA, AB, AC, AD1, AE, AF1, AG, N/A<br />
AH, AI, AJ, AK1, AL, AM1, AN1,<br />
AN3, AO, AP, AQ1, AR1 and AU<br />
Single leaf inw ard<br />
opening doorset<br />
516a/03 Wilton Single leaf outw ard<br />
opening doorset<br />
516a/04 Halton Single leaf outw ard<br />
opening doorset<br />
516a/05 Sandhurst Double leaf outw ard<br />
opening doorset<br />
516a/06 Wilton Double leaf outw ard<br />
opening doorset<br />
516a/07 Halton Double leaf outw ard<br />
opening doorset<br />
54 AA, AB, AC, AD, AD1, AE, AF,<br />
AF1, AG, AH, AI, AJ, AK, AL,<br />
AM, AN1, AN2, AO, AP, AQ, AR<br />
and AU<br />
46 AA, AB, AC, AD1, AE, AF1, AI,<br />
AJ, AK1, AL, AM1, AO, AP, AQ1<br />
and AR1<br />
54 AA, AB, AC, AD, AD1, AE, AF,<br />
AF1, AI, AJ, AK, AL, AM, AO,<br />
AP, AQ and AR<br />
55 AC1, AJ1, AK2, AL, AM2, AN,<br />
AP1, AQ2, AR2 and AS<br />
55 AC1, AJ1, AK2, AL, AM2, AN,<br />
AP1, AQ2, AR2 and AS<br />
46 AD1, AE, AF1, AK1, AL, AM1,<br />
AN1, AN3, AQ1 and AR1<br />
54 AD, AE, AF, AK, AL, AM, AN1,<br />
AN2, AQ and AR<br />
55 AK2, AL , AM2, AN, AQ2, AR2<br />
and AS<br />
55 AK2, AL , AM2, AN, AQ2, AR2<br />
and AS<br />
N/A<br />
N/A<br />
N/A<br />
N/A<br />
N/A<br />
AT or tw o-point bolting version<br />
of locking system on the active<br />
leaf<br />
AT or tw o-point bolting version<br />
of locking system on the active<br />
leaf<br />
AT or tw o-point bolting version<br />
of locking system on the active<br />
leaf<br />
AT or tw o-point bolting version<br />
of locking system on the active<br />
leaf<br />
Compatible Locks<br />
348 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Compatible Manufacturer Model Type Compatible Cylinders<br />
Locking<br />
System<br />
AA Surelock McGill Trimlock (D117) Three point mortice locking system 4, 5 1 , 7, 8 1 , 14, 15 1 , 19, 20 1 , 24, 25 1 ,<br />
27, 28 1 , 35, 36 1 , 39, 40 1 , 43, 44 1 , 49,<br />
50 1, 54 and 55 1<br />
AB Surelock McGill EX110-L1 Three point surface mounted 22, 29, 33, 46, 51 and 52<br />
emergency exit system fitted w ith<br />
lever handle or push pad and LEO<br />
module<br />
AC Surelock McGill EX210-L1 Three point surface mounted panic 22, 29, 33, 46, 51 and 52<br />
exit system fitted w ith push bar and<br />
LEO module<br />
AC1 Surelock McGill EX210-L2 Three point surface mounted panic<br />
exit system fitted w ith push bar and<br />
'SR4' LEO module<br />
22, 29, 33, 46, 51 and 52<br />
AD Surelock McGill DL200-P Three point surface mounted locking<br />
system w ith automatic cylinder<br />
deadlock operated by key (outside)<br />
and turn-knob (inside)<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
AD1 Surelock McGill DL200-K15P Three point surface mounted locking<br />
system w ith automatic cylinder<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
deadlock operated by key (outside)<br />
and turn-knob (inside) w ith integrated<br />
turn-knob protection shroud<br />
AD2 Surelock McGill DL200-K15P5 Three point surface mounted locking<br />
system w ith automatic cylinder<br />
deadlock operated by key (outside)<br />
and turn-knob (inside) w ith integrated<br />
turn-knob protection shroud<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
AE Surelock McGill DL100 Three point surface mounted locking<br />
system w ith lever-key operated<br />
deadlock<br />
AF Surelock McGill DL106-P Three point surface mounted locking<br />
system w ith cylinder deadlock<br />
operated by key (outside) and turnknob<br />
(inside)<br />
AF1 Surelock McGill DL106-K15P Three point surface mounted locking<br />
system w ith cylinder deadlock<br />
operated by key (outside) and turnknob<br />
(inside) w ith integrated turnknob<br />
protection shroud<br />
N/A<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
20 Nov 2011 349
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
AF2 Surelock McGill DL106-K15P5 Three point surface mounted locking<br />
system w ith cylinder deadlock<br />
operated by key (outside) and turnknob<br />
(inside) w ith integrated turnknob<br />
protection shroud<br />
AG Surelock McGill Stirling DL800 Single point surface mounted locking<br />
w ith K2 and K13P device w ith cylinder deadlock<br />
options<br />
operated by key (outside) and turnknob<br />
(inside)<br />
AH Surelock McGill Stirling EX800 Single point surface mounted<br />
w ith K2 and K13P emergency exit device fitted w ith<br />
options<br />
external key access<br />
AI Surelock McGill A1-L1 Three point surface mounted locking<br />
system fitted w ith lever handle or<br />
push pad and LEO module<br />
AJ Surelock McGill B1-L1 Three point surface mounted panic<br />
exit system fitted w ith push bar and<br />
LEO module<br />
AJ1 Surelock McGill B1-L2 Three point surface mounted panic<br />
exit system fitted w ith push bar and<br />
'SR4' LEO module<br />
AK Surelock McGill C1-P Three point surface mounted locking<br />
system w ith automatic cylinder<br />
deadlock operated by key (outside)<br />
and turn-knob (inside)<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 3, 6, 10, 12, 13, 17, 18, 21, 23, 26,<br />
30, 31, 34, 38, 41, 42, 45, 47, 48, 53,<br />
56, 57 and 58<br />
2, 3, 6, 10, 12, 13, 17, 18, 21, 23, 26,<br />
30, 31, 34, 38, 41, 42, 45, 47, 48, 53,<br />
56, 57 and 58<br />
22, 29, 33, 46, 51 and 52<br />
22, 29, 33, 46, 51 and 52<br />
1, 9, 11, 16, 22, 29, 32, 37, 46, 51<br />
and 52<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
AK1 Surelock McGill C1-K15P Three point surface mounted locking<br />
system w ith automatic cylinder<br />
deadlock operated by key (outside)<br />
and turn-knob (inside) w ith integrated<br />
turn-knob protection shroud<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48 ,<br />
56, 57 and 58<br />
AK2 Surelock McGill C1-K15P5 Three point surface mounted locking<br />
system w ith automatic cylinder<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
deadlock operated by key (outside)<br />
and turn-knob (inside) w ith integrated<br />
turn-knob protection shroud<br />
AL Surelock McGill D1 Three point surface mounted locking<br />
system w ith lever-key operated<br />
deadlock<br />
N/A<br />
350 20 Nov 2011
AM Surelock McGill D6-P Three point surface mounted locking<br />
system w ith cylinder deadlock<br />
operated by key (outside) and turnknob<br />
(inside)<br />
AM1 Surelock McGill D6-K15P Three point surface mounted locking<br />
system w ith cylinder deadlock<br />
operated by key (outside) and turnknob<br />
(inside) w ith integrated turnknob<br />
protection shroud<br />
AM2 Surelock McGill D6-K15P5 Three point surface mounted locking<br />
system w ith cylinder deadlock<br />
operated by key (outside) and turnknob<br />
(inside) w ith integrated turnknob<br />
protection shroud<br />
AN Surelock McGill 25C1-P5R# 2,3 X 25mm throw three point locking<br />
system w ith solenoid 2 deadlock<br />
(pow er to release) and external<br />
cylinder operation<br />
AN1 Surelock McGill 25C1-PR# 2,3 X 25mm throw three point locking<br />
system w ith solenoid 2 deadlock<br />
(pow er to release) and external<br />
cylinder operation<br />
AN2 Surelock McGill 25C1-PR# 2,3 25mm throw three point locking<br />
system w ith solenoid 2 deadlock<br />
(pow er to release) and external<br />
cylinder operation<br />
AN3 Surelock McGill 25C1-K15 PR# 2,3 25mm throw three point locking<br />
system w ith solenoid 2 deadlock<br />
(pow er to release) external cylinder<br />
operation<br />
AO Surelock McGill Slimline 315R-L1<br />
or 315L-L1<br />
AP Surelock McGill Slimline 314R-L1<br />
or 314L-L1<br />
AP1 Surelock McGill Slimline 314R-L2<br />
or 314L-L2<br />
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
Three point surface mounted 22, 29, 33, 46, 51 and 52<br />
emergency exit system fitted w ith<br />
lever handle or push pad and LEO<br />
module 5<br />
Three point surface mounted panic 22, 29, 33, 46, 51 and 52<br />
exit system fitted w ith push bar and<br />
LEO module 6<br />
Three point surface mounted panic 1, 9, 11, 16, 22, 29, 32, 37, 46, 51<br />
exit system fitted w ith push bar and and 52<br />
'SR4' LEO module 6<br />
AQ Surelock McGill Slimline 313-KP Three point surface mounted locking<br />
system w ith automatic cylinder<br />
deadlock operated by key (outside)<br />
and turn-knob (inside)<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
20 Nov 2011 351
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
AQ1 Surelock McGill Slimline 313-<br />
KK15P<br />
AQ2 Surelock McGill Slimline 313-<br />
KK15P5<br />
AR Surelock McGill Slimline 313-A0P Three point surface mounted locking<br />
system w ith cylinder deadlock<br />
operated by key (outside)and turnknob<br />
(inside)<br />
AR1 Surelock McGill Slimline 313-<br />
A0K15P<br />
AR2 Surelock McGill Slimline 313-<br />
A0K15P5<br />
AS Surelock McGill Slimline 325R-<br />
K2P5 R# 2,3 or<br />
325L-K2P5 R# 2,3<br />
Three point surface mounted locking 2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
system w ith automatic cylinder 56, 57 and 58<br />
deadlock operated by key (outside)<br />
and turn-knob (inside) w ith integrated<br />
turn-knob protection shroud<br />
Three point surface mounted locking 2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
system w ith automatic cylinder 56, 57 and 58<br />
deadlock operated by key (outside)<br />
and turn-knob (inside) w ith integrated<br />
turn-knob protection shroud<br />
Three point surface mounted locking<br />
system w ith cylinder deadlock<br />
operated by key (outside) and turnknob<br />
(inside) w ith integrated turnknob<br />
protection shroud<br />
Three point surface mounted locking<br />
system w ith cylinder deadlock<br />
operated by key (outside) and turnknob<br />
(inside) w ith integrated turnknob<br />
protection shroud<br />
25mm throw three point locking<br />
system w ith solenoid 2 deadlock<br />
(pow er to release) and external<br />
cylinder operation<br />
AT Surelock McGill S3TB-W Barrel bolt (2 off) N/A<br />
AU Surelock McGill Stirling AC800 2<br />
Compatible Cylinders<br />
w ith K2 and K13P<br />
options<br />
Single point surface mounted<br />
solenoid 2 (pow er to release) fitted<br />
w ith external key access<br />
Compatible Manufacturer Model Type<br />
Cylinder<br />
1 Abloy Disklock Pro CY404 DP Screw -in single cylinder<br />
2 Abloy Disklock Pro CY405 DP Rim cylinder<br />
3 Abloy Disklock Pro CY303 DP Single Europrofile cylinder<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 10, 12, 17, 21, 30, 31, 41, 42, 48,<br />
56, 57 and 58<br />
2, 3, 6, 10, 12, 13, 17, 18, 21, 23, 26,<br />
30, 31, 34, 38, 41, 42, 45, 47, 48, 53,<br />
56, 57 and 58<br />
4 Abloy Disklock Pro CY304 DP Double Europrofile cylinder (key:key)<br />
5 Abloy Disklock Pro CY305 DP Double Europrofile cylinder (key:thumbturn) 1<br />
6 Assa 4823 Single Europrofile cylinder<br />
7 Assa 4822 Double Europrofile cylinder (key:key)<br />
8 Assa 4824 Double Europrofile cylinder (key:thumbturn) 1<br />
9 Assa 4851 Screw -in single cylinder<br />
10 Assa 4857 Rim cylinder<br />
352 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
11 Assa C5851 Screw -in single cylinder<br />
12 Assa C5857 Rim cylinder<br />
13 Assa Ruko Flexcore - F523 Single Europrofile cylinder<br />
14 Assa Ruko Flexcore - F522 Double Europrofile cylinder (key:key)<br />
15 Assa Ruko Flexcore - F524 Double Europrofile cylinder (key:thumbturn) 1<br />
16 Assa F551 Screw -in single cylinder<br />
17 Assa Ruko Flexcore - F557 Rim cylinder<br />
18 Assa Tw in Combi - C5823 Single Europrofile cylinder<br />
19 Assa Tw in Combi - C5822 Double Europrofile cylinder (key:key)<br />
20 Assa Tw in Combi - C5821 Double Europrofile cylinder (key:thumbturn) 1<br />
21 Bramah C17 Rim cylinder<br />
22 Bramah C17SI Screw -in single cylinder<br />
23 Chubb TXE3010 Single Europrofile cylinder<br />
24 Chubb TXED3030 Double Europrofile cylinder (key:key)<br />
25 Chubb TXET3030 Double Europrofile cylinder (key:thumbturn) 1<br />
26 Dom 333 H RS5 Single Europrofile cylinder<br />
27 Dom 333 RS5 Double Europrofile cylinder (key:key)<br />
28 Dom 333 K RS5 Double Europrofile cylinder (key:thumbturn) 1<br />
29 Dom 419ix10KG Screw -in single cylinder<br />
30 Dom 555ix10G Rim cylinder<br />
31 Kaba KV06.100 Rim cylinder<br />
32 Kaba K207.203 C5-SC Screw -in single cylinder<br />
33 Kaba K2070000C5-SC Armoured screw -in single cylinder<br />
34 Kaba QS 152.100.00 Single Europrofile cylinder<br />
35 Kaba QS 150.100.00 Double Europrofile cylinder (key:key)<br />
36 Kaba QS 151.100.00 Double Europrofile cylinder (key:thumbturn) 1<br />
37 Medeco BX664 Screw -in single cylinder<br />
38 Medeco BX665 Single Europrofile cylinder<br />
39 Medeco BX666 Double Europrofile cylinder (key:key)<br />
40 Medeco BX667 Double Europrofile cylinder (key:thumbturn) 1<br />
41 Medeco BX668 Rim cylinder<br />
42 Union 1x1 Rim cylinder<br />
43 Union 2x18AA Double Europrofile cylinder (key:key)<br />
44 Union 2x19AA Double Europrofile cylinder (key:thumbturn) 1<br />
45 Union 2x20A Single Europrofile cylinder<br />
46 Union 26x11B Screw -in single cylinder<br />
47 Yale 10026 Single Europrofile cylinder<br />
48 Yale 1109.SCP Rim cylinder<br />
49 Yale 22626 Double Europrofile cylinder (key:key)<br />
50 Yale 32626 Double Europrofile cylinder key:thumbturn) 1<br />
20 Nov 2011 353
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
51 Yale PK1133 Pro-key Screw -in single cylinder<br />
52 Medeco M3ARX MOTC-1001 Screw -in single cylinder<br />
53 Medeco M3ARX ESS-000-047 Single Europrofile cylinder<br />
54 Medeco M3ARX ETS-032-032 Double Europrofile cylinder (key:key)<br />
55 Medeco M3ARX ETT-032-032 Double Europrofile cylinder (key:thumbturn) 1<br />
56 Medeco M3ARX RIMC-10516 Rim cylinder<br />
57 AMS CL-OVLD Scandinavian Oval mechatronic cylinder 7<br />
58 AMS CL-CA2D Finish Round mechatronic cylinder 7<br />
Accessories<br />
Accessory Description Compatible Doorsets (LPCB Cert. No. 516a/..)<br />
01 4 03 04 05 4 06 07<br />
Vision panels 150 mm w ide by 350 mm high vision panels 8<br />
<br />
<br />
incorporating Tego S28 glazing units.<br />
Side panels 9 Single timber side panels to either side of the doorset. <br />
Over-panels 9 Single timber overhead panel. <br />
Surface-mounted<br />
cable conduits<br />
Concealed cable<br />
conduits<br />
Cable conduits mounted on the non-attack face of the<br />
leaf, through w hich cables are routed to energise<br />
solenoid-operated locking systems.<br />
Cable conduits concealed w ithin the thickness of the<br />
leaf, through w hich cables are routed to energise<br />
solenoid-operated locking systems.<br />
Supply voltage of solenoid-operated locking systems<br />
<br />
<br />
<br />
Compatible Doorsets<br />
(LPCB Cert. No. 516a/..)<br />
01 and 05<br />
Configuration<br />
Surface-mounted cable Concealed cable<br />
conduits<br />
conduits<br />
Plain doorset 12 V, 24 V and 50 V 12 V, 24 V and 50 V<br />
Doorset w ith vision panels 12 V, 24 V and 50 V 12 V, 24 V and 50 V<br />
Doorset w ith side panels 50 V 50 V<br />
03, 04, 06 and 07<br />
Doorset w ith overhead panels 12 V, 24 V and 50 V 10 12 V, 24 V and 50 V 10<br />
Plain doorset 12 V, 24 V and 50 V -<br />
Doorset w ith side panels 50 V -<br />
Doorset w ith overhead panels 12 V, 24 V and 50 V 10 -<br />
Notes:<br />
1. The ‘thumbturn’ end of the lock cylinder should be located on the non-attack side of the doorset when the doorset is installed. These<br />
cylinders are unsuitable for use with the Trimlock when fitted to the ‘46 mm thick’ version of the Sandhurst doorset.<br />
2. The resistance of these access control locks to ‘non-mechanical’ attack has not been assessed as it is outside the scope of LPS1175.<br />
Likewise, the assessment has not covered possible effects of any susceptibilities relating to the functionality and performance of any<br />
access control equipment that may be used to operate these locking systems. This is because the scope of access control devices<br />
and system configurations that may be used with these locking systems is ‘infinite’. It is therefore recommended that specifiers and<br />
installers satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or that<br />
they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause<br />
the locking system to disengage.<br />
3. This approval covers the use of Surelock McGill’s lock option codes R (12 V), R1 (24 V) and R4 (50 V). These reflect the supply<br />
voltage required and that the locks are configured in the ‘power to release’ mode. The actual voltages that are compatible on each<br />
doorset are identified in the table above entitled ‘Supply voltage of solenoid-operated locking systems’.<br />
4. The vision panels are only approved on the Sandhurst doorsets when used in conjunction with lock options AA, AE, AF1, AD1, AG,<br />
AU, AQ and AR.<br />
5. The approval covers the use of either the H3 or H21 versions of the push pad.<br />
6. The approval covers the use of either the standard or H20 versions of the panic bar.<br />
7. The resistance of the mechatronic cylinders to ‘non-mechanical’ attack has not been assessed as it is outside the scope of LPS 1175.<br />
Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of ancillary<br />
equipment that may be used in conjunction with those cylinders. It is therefore recommended that specifiers satisfy themselves that<br />
the components used are either resistant to electronic methods of attack, or that they are suitably protected from such<br />
tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage.<br />
8. Two locations are approved. These are both 375 mm from the leading edge of the leaf and either 625 mm or 1325 mm from the<br />
bottom of the leaf.<br />
354 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
9. The side and overhead panels are available in fixed and removable variants of the configurations and overall dimensions defined on<br />
documents D12167.01 (Issue A) through to D12167.30 (Issue A). The approval only covers the provision of a single panel to each<br />
side of the doorset, and a single panel above the doorset. The provision of multiple panels in any direction is outside the scope of this<br />
approval.<br />
10. Doorsets with overhead panels and cable conduits are compatible with 12 V, 24 V and 50 V solenoid-operated locking systems on<br />
the basis that cables are not routed via the overhead panels.<br />
Certificate No: 516c to LPS 1175: Issue 7<br />
Hinged Doorsets<br />
Product Product Type<br />
Name<br />
Hendon<br />
Single leaf<br />
inward<br />
opening<br />
doorset<br />
Single leaf<br />
outward<br />
opening<br />
doorset<br />
Double leaf 1<br />
inward<br />
opening<br />
doorset<br />
Double leaf 1<br />
outward<br />
opening<br />
doorset<br />
Minimum<br />
Structural<br />
Opening Height<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.9 2.5 0.7 1.4 2 516c/01<br />
1.9 2.5 0.7 1.4 2<br />
1.9 2.5 1.4 3.0 2 2<br />
1.9 2.5 1.4 3.0 2 2<br />
Compatible Locking Systems<br />
LPCB<br />
Ref. No.<br />
Trade<br />
Name<br />
Type<br />
516c/01 Hendon Single leaf inw ard<br />
opening doorset<br />
Single leaf<br />
outw ard opening<br />
doorset<br />
Double leaf<br />
inw ard opening<br />
doorset<br />
Double leaf<br />
outw ard opening<br />
doorset<br />
Nomimal Leaf<br />
Thickness<br />
(mm)<br />
Com patible Locking Systems<br />
Active Leaf<br />
46 1, 2, 5, 6, 9, 10, 11, 12, 16, 17, 19, 20,<br />
22, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34,<br />
35, 36, 37, 38, 39, 40, 41, 42 and 43<br />
54 1, 2, 3, 5, 6, 7, 8, 9, 10, 11, 12, 16, 17,<br />
18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28,<br />
29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39,<br />
40, 41, 42 and 44<br />
46 2, 5, 6, 9, 10, 11, 12, 16, 17, 19, 20, 22,<br />
25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35,<br />
36, 37, 38, 39, 40, 41, 42 and 43<br />
54 2, 3, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 16,<br />
17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27,<br />
28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38,<br />
39, 40, 41, 42 and 44<br />
46 5, 6, 9, 10, 11, 12, 16, 17, 19, 20, 22, 25<br />
and 26<br />
27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37,<br />
38, 39, 40, 41 and 42<br />
54 3, 5, 6, 7, 8, 9, 10, 11, 12, 16, 17, 18, 19,<br />
20, 21, 22, 23, 24, 25 and 26<br />
27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37,<br />
38, 39, 40, 41 and 42<br />
46 5, 6, 9, 10, 11, 12, 16, 17, 19, 20, 22, 25<br />
and 26<br />
54 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16, 17,<br />
18, 19, 20, 21, 22, 23, 24, 25 and 26<br />
Passive Leaf<br />
N/A<br />
N/A<br />
N/A<br />
N/A<br />
45 or tw o-point version of<br />
the active leaf lock<br />
45<br />
45 or tw o-point version of<br />
the active leaf lock<br />
45<br />
45 or tw o-point version of<br />
the active leaf lock<br />
45 or tw o-point version of<br />
the active leaf lock<br />
Compatible Locks<br />
20 Nov 2011 355
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Locking<br />
System<br />
Manufacturer Model Type Operating Devices Com patible<br />
External Face Internal Face<br />
Cylinders<br />
1 Dom Nemef Nemef<br />
642/17<br />
2 Dom Nemef Nemef<br />
6602/32<br />
Single-point mortice deadlock<br />
w ith internal quick release<br />
handle<br />
Single-point mortice deadlock<br />
3 Surelock McGill SL301-0X-<br />
O0W<br />
Slimline three-point surfacemounted<br />
locking system<br />
4 Surelock McGill SL304-0X- Slimline three-point surfacemounted<br />
W<br />
locking system<br />
5 Surelock McGill SL305- Slimline three-point surfacemounted<br />
H3Q4<br />
locking system<br />
6 Surelock McGill SL305-Q4 Slimline three-point surfacemounted<br />
locking system<br />
7 Surelock McGill SL311-0X- Slimline three-point surfacemounted<br />
A0K0O0PW<br />
locking system w ith<br />
manual bolting and deadlocking<br />
8 Surelock McGill SL311-0X-<br />
K0O0PW<br />
9 Surelock McGill SL313-<br />
A0K15P<br />
Slimline three-point surfacemounted<br />
locking system w ith<br />
manual deadlocking<br />
Slimline three-point surfacemounted<br />
locking system w ith<br />
manual bolting<br />
10 Surelock McGill SL313-A0P Slimline three-point surfacemounted<br />
locking system w ith<br />
manual bolting<br />
16 Surelock McGill SL315- Slimline three-point surfacemounted<br />
H3PW<br />
locking system<br />
17 Surelock McGill SL315-PW Slimline three-point surfacemounted<br />
locking system<br />
18 Surelock McGill SL322-0X-<br />
K2O0R#PW<br />
Slimline three-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
19 Surelock McGill SL322-PR# Slimline three-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
20 Surelock McGill SL323-<br />
K15PR#<br />
Slimline three-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
21 Surelock McGill SL323-P Slimline three-point surfacemounted<br />
locking system<br />
22 Surelock McGill SL323-PR# Slimline three-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
23 Surelock McGill SL325-0X-<br />
H3K2O0R#P<br />
W<br />
24 Surelock McGill SL325-0X-<br />
K2O0R#PW<br />
25 Surelock McGill SL325-<br />
H3PR#<br />
Slimline three-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Slimline three-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Slimline three-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Key 3 and lever<br />
handle<br />
Key 3 and lever<br />
handle<br />
None<br />
Lever handle<br />
Key or<br />
thumbturn and<br />
lever handle<br />
Key and lever<br />
handle<br />
L to T<br />
U to AL<br />
N/A<br />
None Panic bar 4 N/A<br />
None Push pad 5 N/A<br />
None Lever handle N/A<br />
Key 3 and lever<br />
handle<br />
Key 3 and lever<br />
handle<br />
Key 3 and lever<br />
handle<br />
Key 3 and lever<br />
handle<br />
Key 3 and lever<br />
handle<br />
Key 3 and lever<br />
handle<br />
Electric release<br />
w ith key 3<br />
override and<br />
lever handle<br />
Electric release<br />
and lever<br />
handle<br />
Electric release<br />
and lever<br />
handle<br />
Electric release<br />
and lever<br />
handle<br />
Electric release<br />
and lever<br />
handle<br />
Electric release<br />
w ith key 3<br />
override and<br />
lever handle<br />
Electric release<br />
w ith key 3<br />
override and<br />
lever handle<br />
Electric release<br />
and lever<br />
handle<br />
Key and lever<br />
handle<br />
Key and lever<br />
handle<br />
Shrouded<br />
thumbturn and<br />
lever handle<br />
Thumbturn and<br />
lever handle<br />
Push pad 5<br />
Lever handle<br />
Electric release<br />
and lever<br />
handle<br />
Electric release<br />
and lever<br />
handle<br />
Shrouded<br />
thumbturn and<br />
lever handle<br />
Thumbturn and<br />
lever handle<br />
Thumbturn and<br />
lever handle<br />
Push pad 5<br />
Lever handle<br />
Push pad 5<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
356 20 Nov 2011
26 Surelock McGill SL325-PR# Slimline three-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
27 Surelock McGill ST105-<br />
H3Q4<br />
Stirling single-point surfacemounted<br />
locking system<br />
28 Surelock McGill ST105-Q4 Stirling single-point surfacemounted<br />
locking system<br />
29 Surelock McGill ST113- Stirling single-point surfacemounted<br />
K13P<br />
locking system<br />
30 Surelock McGill ST113-K2 Stirling single-point surfacemounted<br />
locking system<br />
31 Surelock McGill ST115- Stirling single-point surfacemounted<br />
H3K13P<br />
locking system<br />
32 Surelock McGill ST115- Stirling single-point surfacemounted<br />
H3K2<br />
locking system<br />
33 Surelock McGill ST115- Stirling single-point surfacemounted<br />
K13P<br />
locking system<br />
34 Surelock McGill ST115-K2 Stirling single-point surfacemounted<br />
locking system<br />
35 Surelock McGill ST122-<br />
K13PR#<br />
36 Surelock McGill ST122-<br />
K2R#<br />
37 Surelock McGill ST123-<br />
K13PR#<br />
38 Surelock McGill ST123-<br />
K2R#<br />
39 Surelock McGill ST125-<br />
H3K13PR#<br />
40 Surelock McGill ST125-<br />
H3K2R#<br />
41 Surelock McGill ST125-<br />
K13PR#<br />
42 Surelock McGill ST125-<br />
K2R#<br />
43 Surelock McGill Trimlock<br />
DL117<br />
44 Surelock McGill Trimlock<br />
DL137<br />
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Stirling single-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Stirling single-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Stirling single-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Stirling single-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Stirling single-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Stirling single-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Stirling single-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Stirling single-point surfacemounted<br />
locking system w ith fail<br />
secure solenoid 6,7<br />
Three-point mortice locking<br />
system<br />
Three-point mortice locking<br />
system<br />
Electric release<br />
w ith key 3<br />
override and<br />
lever handle<br />
Lever handle A to K<br />
None Push pad 5 N/A<br />
None Lever handle N/A<br />
Key 3 and lever Thumbturn and<br />
handle lever handle<br />
Key 3 and lever Thumbturn and<br />
handle lever handle<br />
Key 3 and lever Push pad 5<br />
handle<br />
Key 3 and lever Push pad 5<br />
handle<br />
Key 3 and lever Lever handle<br />
handle<br />
Key 3 and lever Lever handle<br />
handle<br />
Electric release Electric release<br />
and lever and lever<br />
handle handle<br />
Electric release Electric release<br />
w ith key 3 and lever<br />
override and handle<br />
lever handle<br />
Electric release Thumbturn and<br />
and lever lever handle<br />
handle<br />
Electric release Thumbturn and<br />
w ith key 3 lever handle<br />
override and<br />
lever handle<br />
Electric release Push pad 5<br />
and lever<br />
handle<br />
Electric release Push pad 5<br />
w ith key 3<br />
override and<br />
lever handle<br />
Electric release Lever handle<br />
and lever<br />
handle<br />
Electric release Lever handle<br />
w ith key 3<br />
override and<br />
lever handle<br />
Key 3 and lever Key or<br />
handle thumbturn and<br />
lever handle<br />
Key 3 and lever Key or<br />
handle thumbturn and<br />
A to T<br />
A to T<br />
A to T<br />
A to T<br />
A to T<br />
A to T<br />
A to T<br />
A to T<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
A to K<br />
U to AL<br />
U to AL<br />
lever handle<br />
45 Surelock McGill S3TB-W Tow er bolts (2 off) None Tow er bolt N/A<br />
Compatible Cylinders<br />
20 Nov 2011 357
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Cylinder Reference Manufacturer Model Type<br />
A Abloy Disklock Pro CY405 DP Rim cylinder<br />
B Assa 4857 Rim cylinder<br />
C Assa Tw in Combi - C5857 Rim cylinder<br />
D Assa Ruko Flexcore - F557 Rim cylinder<br />
E Bramah C17 Rim cylinder<br />
F Dom 555ix10G Rim cylinder<br />
G Kaba KV06.100 Rim cylinder<br />
H Medeco BX668 Rim cylinder<br />
I Medeco M3ARX RIMC-10516 Rim cylinder<br />
J AMS CL-OVLD Scandinavian Oval mechatronic 8 cylinder<br />
K AMS CL-CA2D Finish Round mechatronic 8 cylinder<br />
L Abloy Disklock Pro CY303 DP Single europrofile cylinder<br />
M Assa 4823 Single europrofile cylinder<br />
N Assa Ruko Flexcore - F523 Single europrofile cylinder<br />
O Assa Tw in Combi - C5823 Single europrofile cylinder<br />
P Chubb TXE3010 Single europrofile cylinder<br />
Q Dom 333 H RS5 Single europrofile cylinder<br />
R Kaba QS 152.100.00 Single europrofile cylinder<br />
S Medeco BX665 Single europrofile cylinder<br />
T Medeco M3ARX ESS-000-047 Single europrofile cylinder<br />
U Abloy Disklock Pro CY304 DP Double europrofile cylinder (key:key)<br />
V Abloy Disklock Pro CY305 DP Double europrofile cylinder (key:thumbturn) 9<br />
W Assa 4822 Double europrofile cylinder (key:key)<br />
X Assa 4824 Double europrofile cylinder (key:thumbturn) 9<br />
Y Assa Ruko Flexcore - F522 Double europrofile cylinder (key:key)<br />
Z Assa Ruko Flexcore - F524 Double europrofile cylinder (key:thumbturn) 9<br />
AA Assa Tw in Combi - C5822 Double europrofile cylinder (key:key)<br />
AB Assa Tw in Combi - C5821 Double europrofile cylinder (key:thumbturn) 9<br />
AC Chubb TXED3030 Double europrofile cylinder (key:key)<br />
AD Chubb TXET3030 Double europrofile cylinder (key:thumbturn) 9<br />
AE Dom 333 RS5 Double europrofile cylinder (key:key)<br />
AF Dom 333 K RS5 Double europrofile cylinder (key:thumbturn) 9<br />
AG Kaba QS 150.100.00 Double europrofile cylinder (key:key)<br />
AH Kaba QS 151.100.00 Double europrofile cylinder (key:thumbturn) 9<br />
AI Medeco BX666 Double europrofile cylinder (key:key)<br />
AJ Medeco BX667 Double europrofile cylinder (key:thumbturn) 9<br />
AK Medeco M3ARX ETS-032-032 Double europrofile cylinder (key:key)<br />
AL Medeco M3ARX ETT-032-032 Double europrofile cylinder (key:thumbturn) 9<br />
Accessories<br />
358 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Accessory Description Compatible Doorsets<br />
(LPCB Ref. No. 516c/01)<br />
Vision panels 150 mm w ide by 350 mm high vision panels 10 incorporating ‘Tecdur DC28’ glazing<br />
11<br />
units.<br />
150 mm w ide by 350 mm high vision panels 10 incorporating ‘Tecdur DC46’ glazing<br />
12<br />
units.<br />
Side panels 13 Single timber side panel to either side of the doorset. <br />
Overhead Single timber overhead panel. <br />
panels 13<br />
Surface-mounted<br />
cable conduits<br />
Cable conduits mounted on the non-attack face of the leaf, through w hich cables<br />
are routed to energise solenoid-operated locking systems.<br />
<br />
Concealed cable<br />
conduits<br />
Cable conduits concealed w ithin the thickness of the leaf, through w hich cables<br />
are routed to energise solenoid-operated locking systems.<br />
<br />
Supply Voltage of Solenoid-Operated Locking Systems<br />
Configuration<br />
Doorset w ith cable conduits<br />
Doorset w ith side panels and cable conduits<br />
Doorset w ith overhead panels and cable conduits<br />
Doorset w ith vision panels and cable conduits<br />
Com patible Doorsets<br />
(LPCB Ref. No. 516c/01 14 )<br />
12 V, 24 V and 50 V<br />
12 V, 24 V and 50 V<br />
12 V, 24 V and 50 V<br />
12 V, 24 V and 50 V<br />
Notes:<br />
1. The approval only covers double leaf doorsets with leafs of equal width.<br />
2. The doorset achieves a Security Rating 2 classification when placed in the optimum locked condition. A Security Rating 1<br />
classification prevails when placed in the minimum locked condition. That condition exists when either:<br />
a. One tower bolt is engaged, the active leaf locking system is engaged and the external key is removed.<br />
b. The two-point manual bolting version of the locking system fitted to the active leaf was disengaged, the active leaf locking system<br />
is engaged and the external key is removed.<br />
3. The external cylinder is protected within a Surelock McGill ‘P’ cylinder guard.<br />
4. The approval covers the use of either the standard or H20 versions of the panic bar.<br />
5. The approval covers the use of either the H3 or H21 versions of the push pad.<br />
6. This approval covers the use of Surelock McGill’s lock option codes R (12 V), R1 (24 V) and R4 (50 V). These reflect the supply<br />
voltage required and that the locks are configured in the ‘power to release’ mode. The actual voltages that are compatible on each<br />
doorset are identified in the table above entitled ‘Supply voltage of solenoid-operated locking systems’.<br />
7. The resistance of these access control locks to ‘non-mechanical’ attack has not been assessed as it is outside the scope of LPS1175.<br />
Likewise, the assessment has not covered possible effects of any susceptibilities relating to the functionality and performance of any<br />
access control equipment that may be used to operate these locking systems. This is because the scope of access control devices<br />
and system configurations that may be used with these locking systems is ‘infinite’. It is therefore recommended that specifiers and<br />
installers satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or that<br />
they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause<br />
the locking system to disengage.<br />
8. The resistance of the mechatronic cylinders to ‘non-mechanical’ attack has not been assessed as it is outside the scope of LPS 1175.<br />
Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of ancillary<br />
equipment that may be used in conjunction with those cylinders. It is therefore recommended that specifiers satisfy themselves that<br />
the components used are either resistant to electronic methods of attack, or that they are suitably protected from such<br />
tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage.<br />
9. The ‘thumbturn’ end of the lock cylinder should be located on the non-attack side of the doorset when the doorset is installed.<br />
10. Two locations are approved. These are both 375 mm from the leading edge of the leaf and either 625 mm or 1325 mm from the<br />
bottom of the leaf.<br />
11. ‘Tecdur DC28’ glazing units should not be used in combination with locking systems 4, 13, 14 or 15.<br />
12. ‘Tecdur DC46’ glazing units should not be used in combination with locking systems 1 to 3, 5 to 12 or 16 to 44.<br />
13. The side and overhead panels are available in fixed and removable variants of the configurations and overall dimensions defined on<br />
documents D12167.01 (Issue A) through to D12167.30 (Issue A). The approval only covers the provision of a single panel to each<br />
side of the doorset, and a single panel above the doorset. The provision of multiple panels in any direction is outside the scope of this<br />
approval.<br />
14. ‘Hendon’ doorsets may incorporate surface-mounted or concealed cable conduits, as illustrated on documents D12183.06 (Issue A)<br />
and D12183.07 (Issue A).<br />
20 Nov 2011 359
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Sunray Engineering Limited<br />
Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL, United Kingdom<br />
Tel: +44 (0)1233 639039 • Fax: +44 (0)1233 625137<br />
E-mail: sales@sunraydoors.co.uk • Website: www.sunraydoors.co.uk<br />
Certificate No: 234c to LPS 1175: Issue 5<br />
Hinged Security Doorsets<br />
Product<br />
Type<br />
Name<br />
ExcluDoor 3<br />
ExcluDoor 4<br />
ExcluDoor 3<br />
ExcluDoor 4<br />
ExcluDoor 4<br />
F.R.<br />
ExlcuDoor 4<br />
F.R.<br />
Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening:<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening:<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Double leaf, outward opening<br />
hinged security doorset<br />
1.8 2.4 1.4 2.4 3 234c/01<br />
Double leaf, outward opening 1.8 2.4 1.24 2.4 4 234c/02<br />
hinged security doorset 10<br />
Single leaf, outward opening 1.8 2.4 0.75 1.24 4 234c/03<br />
hinged security doorset with multipoint<br />
locking systems<br />
Single leaf, outward opening<br />
- <strong>2.2</strong>5 - 1.1 3 234c/04<br />
hinged security doorset<br />
Single leaf, outward opening 1.8 <strong>2.2</strong>5 0.75 1.24 4 234c/05<br />
hinged security doorset with two<br />
single point locks<br />
Single leaf, outward opening 1.8 2.4 0.75 1.24 4 234c/06<br />
hinged security doorset with a<br />
single point lock<br />
Double leaf, outward opening 1.8 2.4 1.24 2.4 4 234c/07<br />
multi point locking systems 10<br />
hinged security doorset with<br />
Single leaf, outward opening 1.8 2.4 0.75 1.24 4 234c/08<br />
hinged security doorset with<br />
multi point locking systems<br />
Cert.<br />
No.<br />
Approved Locking Configurations<br />
LPCB Ref. No. Trade Name Compatible Locking Devices<br />
Active Leaf<br />
Passive Leaf<br />
234c/01 ExcluDoor 3 11, 12 or 32 9<br />
234c/02 ExcluDoor 4 1, 2, 3 1 , 4 1 , 5, 6, 7, 8, 10, 17, 18, 19, 20, 21,<br />
13 or 14<br />
22, 23, 24, 25, 26, 27, 28, 29, 30 or 31<br />
11, 12 or 32 9<br />
234c/03 ExcluDoor 4 6, 7, 8, 15, 16, 17, 18, 19 or 30 N/A<br />
234c/04 ExcluDoor 3 1 or 2 N/A<br />
234c/05 ExcluDoor 4 9 3 or 4 1 N/A<br />
234c/06 ExcluDoor 4 1, 2, 20, 21, 22, 23, 24, 25, 26, 27, 28 or 29 N/A<br />
234c/07 ExcluDoor 4 F.R. 7 13 or 14<br />
234c/08 ExcluDoor 4 F.R. 7 N/A<br />
Compatible Locking Systems<br />
360 20 Nov 2011
Compatible<br />
Locking<br />
System<br />
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Locking System Type Com patible Operating Devices Compatible<br />
Cylinders<br />
External Face Internal Face<br />
1 Assa765 Sash lock Key Key 2 or<br />
Thumbturn 5 Blind<br />
rose<br />
A to D<br />
2 Assa 2788 Dead lock Key Key 2 B or D<br />
3<br />
Assa 765 3 Sash lock Key Thumbturn A or C<br />
Assa 2788 4 Deadlock Key Blind rose A or C<br />
4<br />
Assa 765 3 Sash lock Key Thumbturn A or C<br />
Assa 765 4 Sash lock Key Thumbturn A or C<br />
5 Assa Mico 942-10 2-w ay panic exit device None Push pad N/A<br />
6 Assa Mico 942-3p 3-w ay panic exit device None Push pad N/A<br />
7 Surelock McGill EX210 (B1) 3-w ay panic exit device None Panic bar N/A<br />
8 Surelock McGill EX210 (B1) 3-w ay panic exit device Key and handle<br />
(LEO L1P)<br />
Panic bar<br />
S to W<br />
9 Surelock McGill EX212 (B2) 2-w ay panic exit device None Panic bar N/A<br />
10 Surelock McGill EX212 (B2) 2-w ay panic exit device Key and handle Panic bar<br />
S to W<br />
(LEO L1P)<br />
11 Surelock McGill EX213 (B3) 3-bolt panic exit device None Panic bar N/A<br />
12 Surelock McGill EX213 (B3) 3-bolt panic exit device Key and handle Panic bar<br />
S to W<br />
(LEO L1P)<br />
13 Sunray “D/40083” internal Tw o concealed leading N/A N/A N/A<br />
drop bolt<br />
edge drop bolts<br />
14 Sunray “D/40015” surface Tw o surface mounted high N/A N/A N/A<br />
mounted drop bolt<br />
security barrel bolts<br />
15 Surelock McGill A1 3-w ay locking device None Handle N/A<br />
16 Surelock McGill A1 3-w ay locking device Key and handle Handle<br />
S to W<br />
(LEO L1P)<br />
17 Surelock McGill D3- K13P5 6 3-w ay locking device Key and handle Handle E to R<br />
18 Surelock McGill D6 K13P5 6 3-w ay locking device Key and handle Handle E to R<br />
19 Surelock McGill C1 K13P5 6 3-w ay locking device Key and handle Handle E to R<br />
20 EX800 Single point emergency exit None Handle N/A<br />
device<br />
21 EX800 w ith K13P5 option Single point emergency exit Key and handle Handle E to R<br />
device<br />
22 DL800 Single point deadlock None Thumb turn and N/A<br />
handle<br />
23 DL800 w ith K13P5 option Single point deadlock Key and handle Thumb turn and E to R<br />
handle<br />
24 DL800 w ith K13P5 option Single point deadlock None Break dome<br />
N/A<br />
protection turn<br />
knob and handle<br />
25 DL800 w ith K4 and K13P5<br />
option<br />
Single point deadlock Key and handle Break dome<br />
protection turn<br />
knob and handle<br />
E to R<br />
20 Nov 2011 361
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
26 AC800 Single point electromechanical<br />
access control<br />
lock pow ered by 12V, 24V<br />
or 50 V solenoid 7, 8<br />
27 AC800 w ith X option Single point electromechanical<br />
access control<br />
lock pow ered by 12V, 24V<br />
or 50 V solenoid 7, 8<br />
28 AC800 w ith K13P5 option Single point electromechanical<br />
access control<br />
lock pow ered by 12V, 24V<br />
or 50 V solenoid 7, 8<br />
29 AC800 w ith K13P5 and K9<br />
options<br />
Single point electromechanical<br />
access control<br />
lock pow ered by 12V, 24V<br />
or 50 V solenoid 7, 8<br />
Handle plus<br />
external access<br />
control entry<br />
device (e.g. key<br />
pad or sw ipe<br />
card etc)<br />
Handle plus<br />
external access<br />
control entry<br />
device (e.g. key<br />
pad or sw ipe<br />
card etc)<br />
Handle plus<br />
external access<br />
control entry<br />
device (e.g. key<br />
pad or sw ipe<br />
card etc)<br />
Handle plus<br />
external access<br />
control entry<br />
device (e.g. key<br />
pad or sw ipe<br />
card etc)<br />
30 Surelock McGill EX210 (B1) 3-w ay panic exit device Key and handle<br />
(LEO L2)<br />
31 Surelock McGill EX212 (B2) 2-w ay panic exit device Key and handle<br />
(LEO L2)<br />
32 Surelock McGill EX213 (B3) 3-bolt panic exit device Key and handle<br />
(LEO L2)<br />
Compatible Cylinders<br />
Handle<br />
Handle<br />
Handle<br />
Handle and<br />
thumbturn<br />
Panic bar<br />
Panic bar<br />
Panic bar<br />
N/A<br />
N/A<br />
E to R<br />
E to R<br />
T to AE<br />
T to AE<br />
T to AE<br />
Cylinder Manufacturer Model Type<br />
Reference<br />
A Assa 601 Oval profile cylinder<br />
B Assa 602 Oval profile cylinder<br />
C Assa Tw in Combi C5801 Oval profile cylinder<br />
D Assa Tw in Combi C5802 Oval profile cylinder<br />
E Abloy CY405DP Rim cylinder<br />
F Abloy CY405PT Rim cylinder<br />
G Assa 4857 Rim cylinder<br />
H Assa C5857 Rim cylinder<br />
I Assa Ruko Flexcore - F557 Rim cylinder<br />
J Bramah C17 Rim cylinder<br />
K Dom 555ix10G Rim cylinder<br />
L Kaba KV06.100 Rim cylinder<br />
M Medeco BX668 Rim cylinder<br />
N Medico M3 ARX Rim cylinder<br />
O Union 1x1 Rim cylinder<br />
P Yale 1109.SCP Rim cylinder<br />
Q AMS CL-OVLD 11 Scandinavian oval profile mechatronic cylinder<br />
R AMS CL-CA2D 11 Finnish Round profile mechatronic cylinder<br />
S Winkhaus VS629 Screw -in cylinder<br />
T Union 26x11B Screw -in cylinder<br />
U Abloy CY404DP Screw -in cylinder<br />
362 20 Nov 2011
V Abloy CY404PT Screw -in cylinder<br />
W Assa Tw in-Combi C5851 Screw -in cylinder<br />
X Assa 4851 Screw -in cylinder<br />
Y Assa F551 Screw -in cylinder<br />
Z Bramah C17SI Screw -in cylinder<br />
AA Dom 419ix10KG Screw -in cylinder<br />
AB Kaba K207.203 C5-SC Screw -in cylinder<br />
AC Medico 664 Screw -in cylinder<br />
AD Medico M3ARX MOTC-1001 Screw -in cylinder<br />
AE Yale PK1133 ProKey Screw -in cylinder<br />
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Notes:<br />
1. In order to achieve the required security rating, both locks must be activated.<br />
2. The security rating will not be achieved if the key is left in the lock on the inside of the door or if the door is placed in the emergency<br />
exit mode.<br />
3. Lock fitted to the upper lock position.<br />
4. Lock fitted to the lower lock position.<br />
5. The D/40047/L thumbturn protection shroud shall be fitted when this hardware is fitted to the ExcluDoor 4 double doorset.<br />
6. Device must be deadlocked if the doorset is to provide resistance to attack commensurate with Security Rating 4.<br />
7. Fail secure version only.<br />
8. The resistance of the access control locks to “non-mechanical” attack has not been assessed as it is outside the scope of LPS1175.<br />
Likewise, the assessment has not covered possible effects of any susceptibilities relating to the functionality and performance of any<br />
access control equipment that may be used to operate these locking systems. This is because the scope of access control devices<br />
and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that Sunray<br />
Engineering satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or<br />
that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may<br />
cause the locking system to disengage.<br />
9. The ExcluDoor 4 single leaf doorset (certificate number 234c/05) is also certified for 30 minutes integrity against the requirements of<br />
LPS1056: Issue 5. See LPCB Certificate No. 234b or Volume 2, Part 2, Section 1.1 of the Red Book for details.<br />
10. The ExcluDoor 4 double leaf doorset can be produced with leafs of unequal width. The maximum width of both leaves is 1173.5 mm.<br />
The minimum width of active leaf approved is 615 mm and the minimum width of passive leaf approved is 300 mm.<br />
11. The resistance of the mechatronic cylinders to “non-mechanical” attack has not been assessed as it is outside the scope of LPS<br />
1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of<br />
ancillary equipment that may be used in conjunction with those cylinders. It is therefore recommended that specifiers satisfy<br />
themselves that the components used are either resistant to electronic methods of attack, or that they are suitably protected from<br />
such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to<br />
disengage.<br />
Certificate No: 234d to LPS 1175: Issue 7<br />
Hinged Security Doorsets<br />
Product Name Type Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
ExcluDoor 3 Mk2 Single leaf, outward opening hinged<br />
security doorset<br />
Double leaf, outward opening<br />
ExecDoor 2<br />
ExcluDoor 4 Mk2<br />
ExcluDoor 4 Mk2<br />
F.R.<br />
ExcluDoor 5<br />
ExcluDoor 4 Mk3<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.8 2.4 0.75 1.24 3 234d/01<br />
1 1.8 2.4 1.24 2.4 3 234d/02<br />
Single leaf, outward opening hinged 1.8 <strong>2.2</strong> 0.75 1.3 2 234d/03<br />
security doorset<br />
Double leaf, outward opening 1.8 <strong>2.2</strong> 1.5 2.5 2 234d/04<br />
hinged security doorset 2<br />
Single leaf, outward opening hinged 1.8 2.4 0.75 1.24 4 234d/05<br />
security doorset<br />
Double leaf, outward opening 1.8 2.4 1.24 2.4 4 234d/06<br />
hinged security doorset 3<br />
Single leaf, outward opening hinged 1.8 2.4 0.75 1.24 4 234d/07<br />
security doorset<br />
Double leaf, outward opening 1.8 2.4 1.24 2.4 4 234d/08<br />
hinged security doorset 3<br />
Single leaf, outward opening hinged 1.8 2.4 0.75 1.24 5 234d/09<br />
security doorset<br />
Double leaf, outward opening 1.8 2.4 1.24 2.4 5 234d/10<br />
hinged security doorset 4<br />
Single leaf, outward opening hinged 1.8 2.4 0.75 1.24 4 234d/11<br />
security doorset<br />
Double leaf, outward opening 1.8 2.4 1.24 2.4 4 234d/12<br />
hinged security doorset 4<br />
20 Nov 2011 363
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Product Name Type Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
ExcluDoor 3 Mk3<br />
F.R.<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Single leaf, outward opening hinged 1.8 2.4 0.75 1.24 3 234d/13<br />
security doorset<br />
Double leaf, outward opening<br />
hinged security doorset 3 1.8 2.4 1.24 2.4 3 234d/14<br />
Cert.<br />
No.<br />
Approved Locking Configurations<br />
LPCB Ref.<br />
No.<br />
Product Name Type Compatible Locking Systems<br />
Active Leaf<br />
Passive Leaf<br />
234d/01 ExcluDoor 3 Mk2 Single leaf, outw ard opening hinged security doorset 1 to 51 -<br />
234d/02 ExcluDoor 3 Mk2 Double leaf, outw ard opening hinged security doorset 1 to 51 52 or 53<br />
234d/03 ExecDoor 2 Single leaf outw ard opening hinged security doorset 54 to 60 -<br />
234d/04 ExecDoor 2 Double leaf outw ard opening hinged security doorset 54 to 60 61 or 62<br />
234d/05 ExcluDoor 4 Mk2 Single leaf, outw ard opening hinged security doorset 63 to 80 N/A<br />
234d/06 ExcluDoor 4 Mk2 Double leaf, outw ard opening hinged security doorset 63 to 71 52 or 53<br />
234d/07 ExcluDoor 4 Mk2 F.R. Single leaf, outw ard opening hinged security doorset 63 to 71 N/A<br />
234d/08 ExcluDoor 4 Mk2 F.R. Double leaf, outw ard opening hinged security doorset 63 to 71 52 or 53<br />
234d/09 ExcluDoor 5 Single leaf, outw ard opening hinged security doorset 81 to 102 N/A<br />
234d/10 ExcluDoor 5 Double leaf, outw ard opening hinged security doorset 81 to 102 52 or 53<br />
234d/11 ExcluDoor 4 Mk3 Single leaf, outw ard opening hinged security doorset 81 to 102 N/A<br />
234d/12 ExcluDoor 4 Mk3 Double leaf, outw ard opening hinged security doorset 81 to 102 52 or 53<br />
234d/13 ExcluDoor 3 Mk3 F.R. Single leaf, outw ard opening hinged security doorset 63 to 71 N/A<br />
234d/14 ExcluDoor 3 Mk3 F.R. Double leaf, outw ard opening hinged security doorset 63 to 71 52 or 53<br />
Compatible Locking Systems<br />
Compatible<br />
Locking<br />
Systems<br />
Manufacturer Model Type Com patible Operating Devices<br />
1 Surelock McGill<br />
Limited<br />
2 Surelock McGill<br />
Limited<br />
3 Surelock McGill<br />
Limited<br />
4 Surelock McGill<br />
Limited<br />
5 Surelock McGill<br />
Limited<br />
6 Surelock McGill<br />
Limited<br />
External Face<br />
Internal Face<br />
Stirling EX800 Single point emergency<br />
exit device<br />
None Handle N/A<br />
Stirling EX800 w ith Single point emergency Key and handle Handle Z, AB to AI,<br />
K13P option exit device<br />
AX<br />
Stirling DL800 Single point deadlock None Thumb turn and N/A<br />
handle<br />
Stirling DL800 w ith Single point deadlock Key and handle Thumb turn and Z, AB to AI,<br />
K13P option<br />
handle<br />
AX<br />
Stirling DL800 w ith Single point deadlock None Break dome N/A<br />
K4 option<br />
protection turn<br />
knob and handle<br />
Stirling DL800 w ith<br />
K4 and K13P<br />
option<br />
Single point deadlock Key and handle Break dome<br />
protection turn<br />
knob and handle<br />
Compatible<br />
Cylinders<br />
Z, AB to AI,<br />
AX<br />
364 20 Nov 2011
7 Surelock McGill<br />
Limited<br />
8 Surelock McGill<br />
Limited<br />
9 Surelock McGill<br />
Limited<br />
10 Surelock McGill<br />
Limited<br />
11 Surelock McGill<br />
Limited<br />
12 Surelock McGill<br />
Limited<br />
13 Surelock McGill<br />
Limited<br />
14 Surelock McGill<br />
Limited<br />
15 Surelock McGill<br />
Limited<br />
16 Surelock McGill<br />
Limited<br />
17 Surelock McGill<br />
Limited<br />
Stirling AC800<br />
Stirling AC800 w ith<br />
X option<br />
Stirling AC800 w ith<br />
K13P option<br />
Stirling AC800 w ith<br />
K13P and K9<br />
options<br />
Slimline<br />
SL305-00-H3<br />
Slimline<br />
SL304-00<br />
Slimline<br />
SL305-0x-H3Lon<br />
Slimline<br />
SL304-0x-Lon<br />
Slimline<br />
SL324-0x-<br />
K2OnPRn<br />
Slimline<br />
SL325-0x-<br />
H3K2OnPRn<br />
Slimline<br />
SL325-0x-<br />
K2OnPRn<br />
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Single point electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5<br />
Single point electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5<br />
Single point electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5<br />
Single point electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5<br />
Handle plus<br />
external access<br />
control entry<br />
device (e.g. key<br />
pad or sw ipe<br />
card etc) 6 Handle N/A<br />
Handle plus Handle N/A<br />
card etc) 6<br />
external access<br />
control entry<br />
device (e.g. key<br />
pad or sw ipe<br />
Handle and key Handle Z, AB to AI,<br />
sw ipe card etc.) 6<br />
or external<br />
AX<br />
access control<br />
entry device<br />
(e.g. key pad or<br />
Handle and key<br />
or external<br />
access control<br />
entry device<br />
(e.g. key pad or<br />
sw ipe card etc.) 6<br />
Handle and<br />
thumb turn<br />
Z, AB to AI,<br />
AX<br />
3-w ay emergency exit None Push pad N/A<br />
device<br />
3-w ay panic exit device None Panic bar N/A<br />
3-w ay emergency exit<br />
device<br />
Key and handle<br />
(LEO L1P)<br />
Push pad<br />
BB, BC, BE,<br />
BI<br />
3-w ay panic exit device Key and handle<br />
(LEO L1P)<br />
Panic bar BB, BC, BE,<br />
BI<br />
3-w ay panic exit device Handle and key Panic bar Z, AB to AI,<br />
sw ipe card etc.) 6<br />
w ith electro-mechanical or external<br />
AX<br />
access control lock access control<br />
pow ered by 12 V, 24 V entry device<br />
or 50 V solenoid 5 (e.g. key pad or<br />
3-w ay emergency exit<br />
device w ith electromechanical<br />
access<br />
control lock pow ered<br />
by 12 V, 24 V or 50 V<br />
solenoid 5<br />
3-w ay emergency exit<br />
device w ith electromechanical<br />
access<br />
control lock pow ered<br />
by 12 V, 24 V or 50 V<br />
solenoid 5<br />
Handle and key<br />
or external<br />
access control<br />
entry device<br />
(e.g. key pad or<br />
sw ipe card etc.) 6 Push pad Z, AB to AI,<br />
AX<br />
Handle and key<br />
or external<br />
access control<br />
entry device<br />
(e.g. key pad or<br />
sw ipe card etc.) 6 Handle Z, AB to AI,<br />
AX<br />
20 Nov 2011 365
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
18 Surelock McGill<br />
Limited<br />
19 Surelock McGill<br />
Limited<br />
20 Tindall<br />
Engineering Ltd<br />
21 Tindall<br />
Engineering Ltd<br />
22 Tindall<br />
Engineering Ltd<br />
23 Tindall<br />
Engineering Ltd<br />
24 Tindall<br />
Engineering Ltd<br />
25 Tindall<br />
Engineering Ltd<br />
26 Tindall<br />
Engineering Ltd<br />
27 Tindall<br />
Engineering Ltd<br />
28 Tindall<br />
Engineering Ltd<br />
29 Tindall<br />
Engineering Ltd<br />
30 Tindall<br />
Engineering Ltd<br />
31 Tindall<br />
Engineering Ltd<br />
32 Tindall<br />
Engineering Ltd<br />
33 Tindall<br />
Engineering Ltd<br />
34 Tindall<br />
Engineering Ltd<br />
35 Tindall<br />
Engineering Ltd<br />
36 Tindall<br />
Engineering Ltd<br />
37 Tindall<br />
Engineering Ltd<br />
38 Tindall<br />
Engineering Ltd<br />
Slimline<br />
SL305-0x-H3L2on<br />
3-w ay emergency exit<br />
device<br />
Key and handle<br />
(LEO L2)<br />
Push pad BB to BH<br />
Slimline 3-w ay panic exit device Key and handle Panic bar BB to BH<br />
SL304-0x-L2on<br />
(LEO L2)<br />
Mico 942 / ELK 3 2-w ay panic exit device Key and handle Panic bar AM to AZ<br />
(ELK3)<br />
Mico 942 2-w ay panic exit device None Panic bar N/A<br />
Mico 942P / ELK 3 2-w ay emergency exit<br />
device<br />
Key and handle<br />
(ELK3)<br />
Push pad AM to AZ<br />
Mico 942P 2-w ay emergency exit None Push pad N/A<br />
device<br />
Mico 942L / ELK 3 2-w ay emergency exit Key and handle Lever handle AM to AZ<br />
device<br />
(ELK3)<br />
Mico 942L 2-w ay emergency exit None Lever handle N/A<br />
device<br />
Mico 942L INT AD 2-w ay locking system None Thumb turn and N/A<br />
w ith automatic deadlock<br />
lever handle<br />
Mico 942 INT MD<br />
Mico 942P INT MD<br />
Mico 942L INT MD<br />
2-w ay locking system<br />
w ith manual deadlock<br />
2-w ay locking system<br />
w ith manual deadlock<br />
2-w ay locking system<br />
w ith manual deadlock<br />
None<br />
None<br />
None<br />
Thumb turn and<br />
full w idth push<br />
plate 7<br />
Thumb turn and<br />
push pad<br />
Thumb turn and<br />
lever handle<br />
Mico 942-3 / ELK 3 3-w ay panic exit device Key and handle<br />
(ELK3)<br />
Panic bar AM to AZ<br />
Mico 942-3 3-w ay panic exit device None Panic bar N/A<br />
Mico 942-3P / ELK<br />
3<br />
3-w ay emergency exit<br />
device<br />
Key and handle<br />
(ELK3)<br />
Push pad AM to AZ<br />
Mico 942-3P 3-w ay emergency exit None Push pad N/A<br />
device<br />
Mico 942-3L / ELK 3-w ay emergency exit Key and handle Lever handle AM to AZ<br />
3<br />
device<br />
(ELK3)<br />
Mico 942-3L 3-w ay emergency exit None Lever handle N/A<br />
device<br />
Mico 942-3L INT 3-w ay locking system None Thumb turn and N/A<br />
AD w ith automatic deadlock<br />
lever handle<br />
Mico 942-3 INT MD 3-w ay locking system None Thumb turn and N/A<br />
w ith manual deadlock<br />
full w idth push<br />
plate 7<br />
Mico 942-3P INT 3-w ay locking system None Thumb turn and N/A<br />
MD w ith manual deadlock<br />
push pad<br />
N/A<br />
N/A<br />
N/A<br />
366 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
39 Tindall<br />
Engineering Ltd<br />
40 Tindall<br />
Engineering Ltd<br />
41 Tindall<br />
Engineering Ltd<br />
42 Tindall<br />
Engineering Ltd<br />
43 Tindall<br />
Engineering Ltd<br />
44 Tindall<br />
Engineering Ltd<br />
45 Tindall<br />
Engineering Ltd<br />
46 Tindall<br />
Engineering Ltd<br />
47 Tindall<br />
Engineering Ltd<br />
48 Tindall<br />
Engineering Ltd<br />
49 Tindall<br />
Engineering Ltd<br />
50 Tindall<br />
Engineering Ltd<br />
51 Tindall<br />
Engineering Ltd<br />
Mico 942-3L INT<br />
MD<br />
Mico 942 EM SEC<br />
Mico 942P EM SEC<br />
Mico 942L EM SEC<br />
Mico 942 SATE EM<br />
SEC<br />
Mico 942P SATE<br />
EM SEC<br />
Mico 942L SATE<br />
EM SEC<br />
Mico 942-3 EM SEC<br />
Mico 942-3P EM<br />
SEC<br />
Mico 942-3L EM<br />
SEC<br />
Mico 942-3 SATE<br />
EM SEC<br />
Mico 942-3P SATE<br />
EM SEC<br />
Mico 942-3L SATE<br />
EM SEC<br />
3-w ay locking system<br />
w ith manual deadlock<br />
2-w ay locking system<br />
w ith automatic deadlock<br />
None<br />
Access control<br />
system and lever<br />
handle 5,6<br />
2-w ay locking system Access control<br />
w ith automatic deadlock system and lever<br />
handle 5,6<br />
2-w ay locking system Access control<br />
w ith automatic deadlock system and lever<br />
handle 5,6<br />
2-w ay panic exit device<br />
w ith automatic<br />
deadlocking<br />
2-w ay emergency exit<br />
device w ith automatic<br />
deadlocking<br />
2-w ay emergency exit<br />
device w ith automatic<br />
deadlocking<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
3-w ay locking system<br />
w ith automatic<br />
deadlocking<br />
3-w ay panic exit device<br />
w ith automatic<br />
deadlocking<br />
3-w ay emergency exit<br />
device w ith automatic<br />
deadlocking<br />
3-w ay emergency exit<br />
device w ith automatic<br />
deadlocking<br />
Thumb turn and<br />
lever handle<br />
Access control<br />
and thumb turn<br />
override w ith full<br />
w idth push plate 7<br />
Access control<br />
and thumb turn<br />
override w ith<br />
push pad<br />
Access control<br />
and thumb turn<br />
override w ith<br />
lever handle<br />
N/A<br />
N/A<br />
N/A<br />
N/A<br />
Access control Panic bar N/A<br />
handle 5,6<br />
system and lever<br />
Access control Push pad N/A<br />
handle 5,6<br />
system and lever<br />
Access control Lever handle N/A<br />
handle 5,6<br />
system and lever<br />
Access control<br />
system and lever<br />
handle 5,6<br />
Access control<br />
system and lever<br />
handle 5,6<br />
Access control<br />
system and lever<br />
handle 5,6<br />
Access control<br />
and thumb turn<br />
override w ith full<br />
w idth push plate 7<br />
Access control<br />
and thumb turn<br />
override w ith<br />
push pad<br />
Access control<br />
and thumb turn<br />
override w ith<br />
lever handle<br />
N/A<br />
N/A<br />
N/A<br />
Access control Panic bar N/A<br />
handle 5,6<br />
system and lever<br />
Access control<br />
system and lever<br />
handle 5,6 Push pad N/A<br />
Access control Lever handle N/A<br />
handle 5,6<br />
system and lever<br />
20 Nov 2011 367
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
52 Sunray<br />
Engineering Ltd<br />
Sunray surface<br />
mounted drop bolts<br />
Tw o surface mounted<br />
drop bolts<br />
None<br />
Surface mounted<br />
drop bolts<br />
53 Sunray Sunray internal Tw o internal drop bolts None Internal drop N/A<br />
Engineering Ltd drop bolts<br />
bolts<br />
54 Assa 765 Sash lock Key and lever Key and lever BA<br />
handle<br />
handle<br />
55 Assa 765 Sash lock Key and lever Thumbturn and AS<br />
handle lever handle<br />
56 Assa 2788 Dead lock Key Key BA<br />
57 Assa 2788 Dead lock Key Thumbturn AS<br />
58 Exidor 803 Three point panic exit<br />
device 8 None Panic bar N/A<br />
59 Exidor 803 w ith 809 Three point panic exit<br />
device w ith outside<br />
access device 8<br />
60 Exidor 803 w ith 810 Three point panic exit<br />
device w ith outside<br />
access device 8<br />
Key and turn<br />
knob (Exidor<br />
809)<br />
Key and handle<br />
(Exidor 810)<br />
Panic bar<br />
Panic bar<br />
None Panic bar N/A<br />
61 Exidor 802 Tw o point panic exit<br />
device 9<br />
62 Exidor HS923/10 Tw o tow er bolts None Tow er bolts N/A<br />
63 Surelock McGill<br />
Limited<br />
64 Surelock McGill<br />
Limited<br />
65 Surelock McGill<br />
Limited<br />
66 Surelock McGill<br />
Limited<br />
67 Surelock McGill<br />
Limited<br />
68 Surelock McGill<br />
Limited<br />
69 Surelock McGill<br />
Limited<br />
70 Surelock McGill<br />
Limited<br />
Slimline SL301 Three point deadlock None Internal key and<br />
handle<br />
N/A<br />
Slimline SL303 Three point deadlock None Thumb turn and N/A<br />
handle (K4 breakdome<br />
optional)<br />
Slimline SL305 Three point emergency None Handle N/A<br />
exit device<br />
Slimline SL311-P5 Three point deadlock Key and lever Internal key and Z, AB to AI,<br />
handle<br />
handle<br />
AX<br />
Slimline SL313-P5 Three point deadlock Key and lever<br />
handle<br />
Slimline SL315-P5<br />
Slimline SL321-P5<br />
Slimline SL323-P5<br />
Three point emergency<br />
exit device<br />
Three point deadlock<br />
incorporating electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5,6<br />
Three point deadlock<br />
incorporating electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5,6<br />
Key and lever<br />
handle<br />
Handle plus<br />
external access<br />
control entry<br />
device and key<br />
override<br />
Handle plus<br />
external access<br />
control entry<br />
device and key<br />
override<br />
Thumb turn and<br />
handle (K4 breakdome<br />
optional)<br />
Handle<br />
Internal key/<br />
access control<br />
and handle<br />
Thumb turn/<br />
access control<br />
and handle (K4<br />
break-dome<br />
optional)<br />
N/A<br />
Y<br />
Y<br />
Z, AB to AI,<br />
AX<br />
Z, AB to AI,<br />
AX<br />
Z, AB to AI,<br />
AX<br />
Z, AB to AI,<br />
AX<br />
368 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
71 Surelock McGill<br />
Limited<br />
72 Surelock McGill<br />
Limited<br />
73 Surelock McGill<br />
Limited<br />
74 Surelock McGill<br />
Limited<br />
75 Surelock McGill<br />
Limited<br />
76 Surelock McGill<br />
Limited<br />
77 Surelock McGill<br />
Limited<br />
78 Surelock McGill<br />
Limited<br />
79 Surelock McGill<br />
Limited<br />
80 Surelock McGill<br />
Limited<br />
81 Surelock McGill<br />
Limited<br />
82 Surelock McGill<br />
Limited<br />
Slimline SL325-P5<br />
Three point emergency<br />
exit device<br />
incorporating electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5,6<br />
Handle plus<br />
external access<br />
control entry<br />
device and key<br />
override<br />
Handle<br />
Z, AB to AI,<br />
AX<br />
Stirling ST101 Single point deadlock None Internal key and<br />
handle<br />
N/A<br />
Stirling ST103 Single point deadlock None Thumb turn and N/A<br />
handle (K4 breakdome<br />
optional)<br />
Stirling ST105 Single point emergency None Handle N/A<br />
exit device<br />
Stirling ST111-P5 Single point deadlock Key and lever Internal key and Z, AB to AI,<br />
handle<br />
handle<br />
AX<br />
Stirling ST113-P5 Single point deadlock Key and lever Thumb turn and Z, AB to AI,<br />
handle handle (K4 breakdome<br />
AX<br />
optional)<br />
Stirling ST115-P5 Single point emergency<br />
exit device<br />
Key and lever<br />
handle<br />
Handle<br />
Stirling ST121-P5 Single point deadlock Handle plus Internal key/<br />
incorporating electromechanical<br />
external access access control<br />
access control entry and handle<br />
control lock pow ered device and key<br />
by 12V, 24V or 50V override<br />
solenoid 5,6<br />
Stirling ST123-P5 Single point deadlock Handle plus Thumb turn/<br />
incorporating electromechanical<br />
external access access control<br />
access control entry and handle (K4<br />
control lock pow ered device and key break-dome<br />
by 12V, 24V or 50V override optional)<br />
solenoid 5,6<br />
Stirling ST125-P5 Single point emergency Handle plus Handle<br />
exit device external access<br />
incorporating electromechanical<br />
control entry<br />
access device and key<br />
control lock pow ered override<br />
by 12V, 24V or 50V<br />
solenoid 5,6<br />
Slimline SL305 Three point emergency<br />
exit device<br />
Slimline SL303 Three point deadlock None Thumb turn and<br />
handle (K4 breakdome<br />
optional)<br />
Z, AB to AI,<br />
AX<br />
Z, AB to AI,<br />
AX<br />
Z, AB to AI,<br />
AX<br />
Z, AB to AI,<br />
AX<br />
None Handle N/A<br />
N/A<br />
83 Surelock McGill<br />
Limited<br />
84 Surelock McGill<br />
Limited<br />
Slimline SL301 Three point deadlock None Internal key and<br />
handle<br />
Slimline SL315-P6 Three point emergency Key and lever Handle<br />
exit device<br />
handle<br />
N/A<br />
Z, AB to AI,<br />
AX<br />
20 Nov 2011 369
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
85 Surelock McGill<br />
Limited<br />
Slimline SL313-P6 Three point deadlock Key and lever<br />
handle<br />
Thumb turn and<br />
handle (K4 breakdome<br />
optional)<br />
Z, AB to AI,<br />
AX<br />
86 Surelock McGill<br />
Limited<br />
87 Surelock McGill<br />
Limited<br />
88 Surelock McGill<br />
Limited<br />
89 Surelock McGill<br />
Limited<br />
90 Tindall<br />
Engineering Ltd<br />
91 Tindall<br />
Engineering Ltd<br />
92 Tindall<br />
Engineering Ltd<br />
93 Tindall<br />
Engineering Ltd<br />
94 Tindall<br />
Engineering Ltd<br />
95 Tindall<br />
Engineering Ltd<br />
96 Tindall<br />
Engineering Ltd<br />
97 Tindall<br />
Engineering Ltd<br />
98 Tindall<br />
Engineering Ltd<br />
Slimline SL311-P6 Three point deadlock Key and lever<br />
handle<br />
Slimline SL325-P6 Three point emergency Handle plus<br />
exit device external access<br />
incorporating electromechanical<br />
control entry<br />
access device and key<br />
control lock pow ered override<br />
by 12V, 24V or 50V<br />
solenoid 5.6<br />
Slimline SL323-P6<br />
Slimline SL321-P6<br />
Abryll PE3<br />
Three point deadlock<br />
incorporating electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5.6<br />
Three point deadlock<br />
incorporating electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5.6<br />
Single point emergency<br />
exit device<br />
Handle plus<br />
external access<br />
control entry<br />
device and key<br />
override<br />
Handle plus<br />
external access<br />
control entry<br />
device and key<br />
override<br />
Internal key and<br />
handle<br />
Handle<br />
Thumb turn/<br />
access control<br />
and handle (K4<br />
break-dome<br />
optional)<br />
Internal key/<br />
access control<br />
and handle<br />
Z, AB to AI,<br />
AX<br />
Z, AB to AI,<br />
AX<br />
Z, AB to AI,<br />
AX<br />
Z, AB to AI,<br />
AX<br />
None Handle N/A<br />
Abryll AD3 Single point deadlock None Thumb turn and<br />
handle<br />
Abryll EPC AD3 Single point deadlock None Internal key and<br />
handle<br />
Abryll SATE AD3 Single point emergency Key and lever Handle<br />
USCH5<br />
exit device<br />
handle<br />
Abryll SATE EPC Single point emergency Key and lever Handle<br />
AD3 USCH5 exit device<br />
handle<br />
Abryll AD3 USCH5 Single point deadlock Key and lever Thumb turn and<br />
handle<br />
handle<br />
Abryll EPC AD3 Single point deadlock Key and lever Thumb turn and<br />
USCH5<br />
handle<br />
handle<br />
Abryll EPC AD3 Single point deadlock Key and lever Internal key and<br />
USCH5<br />
handle<br />
handle<br />
Abryll SATE EM3<br />
Handle<br />
USCH5<br />
Single point emergency<br />
exit device<br />
incorporating electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5.6<br />
Handle plus<br />
external access<br />
control entry<br />
device and key<br />
override<br />
N/A<br />
A to K<br />
Z, AA, AH to<br />
AL, AN to AZ<br />
A to K<br />
Z, AA, AH to<br />
AL, AN to AZ<br />
L to X<br />
A to K<br />
Z, AA, AH to<br />
AL, AN to AZ<br />
370 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
99 Tindall<br />
Engineering Ltd<br />
100 Tindall<br />
Engineering Ltd<br />
101 Tindall<br />
Engineering Ltd<br />
102 Tindall<br />
Engineering Ltd<br />
Abryll EPC SATE<br />
EM3 USCH5<br />
Abryll EPC EM3<br />
USCH5<br />
Abryll EM3 USCH5<br />
Abryll EPC EM3<br />
USCH5<br />
Single point emergency<br />
exit device<br />
incorporating electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5.6<br />
Single point deadlock<br />
incorporating electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5.6<br />
Single point deadlock<br />
incorporating electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5.6<br />
Single point deadlock<br />
incorporating electromechanical<br />
access<br />
control lock pow ered<br />
by 12V, 24V or 50V<br />
solenoid 5.6<br />
Handle plus<br />
external access<br />
control entry<br />
device and key<br />
override<br />
Handle plus<br />
external access<br />
control entry<br />
device and key<br />
override<br />
Handle plus<br />
external access<br />
control entry<br />
device and key<br />
override<br />
Handle plus<br />
external access<br />
control entry<br />
device and key<br />
override<br />
Handle<br />
Thumb turn/<br />
access control<br />
and handle<br />
Thumb turn/<br />
access control<br />
and handle<br />
Internal key/<br />
access control<br />
and handle<br />
A to K<br />
L to X<br />
Z, AA, AH to<br />
AL, AN to AZ<br />
A to K<br />
Compatible Cylinders<br />
Cylinder Manufacturer Model Type ‘Plus’<br />
Reference<br />
rating 10<br />
A Abloy CY304 Protec Europrofile double cylinder (key:key) +<br />
B Access2 Tigres Omega Europrofile double cylinder (key:key) +<br />
C Assa 4822 Europrofile double cylinder (key:key)<br />
D Assa 7622 Europrofile double cylinder (key:key)<br />
E Assa C5822 Europrofile double cylinder (key:key)<br />
F Assa dp4422 Europrofile double cylinder (key:key)<br />
G Kaba Gege RAM Europrofile double cylinder (key:key) +<br />
H Kaba Quattro PluS Europrofile double cylinder (key:key) +<br />
I Medeco M3-ARX Europrofile double cylinder (key:key) +<br />
J Abloy CY304 Protec Cliq 11 Europrofile double cylinder (key:key) (mechatronic) +<br />
K Assa 44M22 Cliq 11 Europrofile double cylinder (key:key) (mechatronic)<br />
L Abloy CY305 Protec Europrofile double cylinder (key:thumbturn) +<br />
20 Nov 2011 371
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
M Abloy CY333 Protec (PT) Europrofile double cylinder (key:thumbturn) +<br />
N Access2 Tigres Omega Europrofile double cylinder (key:thumbturn) +<br />
O Assa 4827 Europrofile double cylinder (key:thumbturn)<br />
P Assa 7627 Europrofile double cylinder (key:thumbturn)<br />
Q Assa 44M27 Cliq 11 Europrofile double cylinder (key:thumbturn)<br />
R Assa C5827 Europrofile double cylinder (key:thumbturn)<br />
S Assa dp4427 Europrofile double cylinder (key:thumbturn)<br />
T Kaba Gege RAM Europrofile double cylinder (key:thumbturn) +<br />
U Kaba Quattro PluS Europrofile double cylinder (key:thumbturn) +<br />
V Medeco M3-ARX Europrofile double cylinder (key:thumbturn) +<br />
W Abloy CY305 Protec Cliq 11 Europrofile double cylinder (key:thumbturn)<br />
(mechatronic)<br />
X Abloy CY333 Protec Cliq 11 Europrofile double cylinder (key:thumbturn)<br />
(mechatronic)<br />
Y Zone 1850 Europrofile single cylinder<br />
Z AMS CL-CA2D 11 Finnish Round cylinder (mechatronic) +<br />
AA Abloy CY403 Protec Rim cylinder +<br />
AB Abloy CY405 Disklock Pro (DP) Rim cylinder +<br />
AC Abloy CY405 ProTec (PT) Rim cylinder +<br />
AD Assa 4857 Rim cylinder<br />
AE Assa C5857 Rim cylinder<br />
AF Bramah C17 Rim cylinder<br />
AG Kaba K20 Rim cylinder<br />
AH Kaba Quattro PluS Rim cylinder +<br />
AI Medico M3ARX Rim cylinder +<br />
AJ Abloy CY403 Protec Cliq 11 Rim cylinder (mechatronic) +<br />
AK Assa 4857 Round threaded cylinder<br />
AL Assa C5857 Round threaded cylinder<br />
AM Abloy CY201 Disklock Pro (DP) Scandinavian Oval cylinder +<br />
AN Abloy CY201 Protec (PT) Scandinavian Oval cylinder +<br />
AO Abloy CY201 Protec Cliq 11 Scandinavian Oval cylinder +<br />
AP Access2 Tigres Omega Scandinavian Oval cylinder +<br />
AQ Assa 4801 Scandinavian Oval cylinder<br />
AR Assa 7601 Scandinavian Oval cylinder<br />
AS Assa C5801 Scandinavian Oval cylinder<br />
AT Assa dp4401 Scandinavian Oval cylinder<br />
AU Kaba K20 Scandinavian Oval cylinder<br />
AV Kaba Quattro PluS Scandinavian Oval cylinder +<br />
AW Medeco M3-ARX Scandinavian Oval cylinder +<br />
AX AMS CL-OVLD 11 Scandinavian Oval cylinder (mechatronic) +<br />
AY Assa 4401 Cliq 11 Scandinavian Oval cylinder (mechatronic)<br />
AZ Locken CL-PL2WR 11 Scandinavian Oval cylinder (mechatronic) +<br />
BA Assa C5802 Scandinavian Oval double cylinder (key:key)<br />
BB Abloy CY404 Disklock Pro (DP) Screw -in cylinder +<br />
+<br />
+<br />
372 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
BC Abloy CY404 Protec (PT) Screw -in cylinder +<br />
BD Assa 4851 Screw -in cylinder<br />
BE Assa C5851 Screw -in cylinder<br />
BF Bramah C17SI Screw -in cylinder<br />
BG Kaba K207.203 C5-SC Screw -in cylinder<br />
BH Medico M3ARX MOTC-1001 Screw -in cylinder +<br />
BI Winkhaus VS629 Screw -in cylinder<br />
Accessories<br />
Accessory Description Certificate number of associated doorset (234d/##)<br />
Full frame<br />
threshold<br />
Low level<br />
threshold w ith<br />
stop<br />
Low level<br />
threshold<br />
Central Tego<br />
vision panel<br />
Offset Tego<br />
vision panel<br />
Vistamatic<br />
Sherman<br />
vision panel 12<br />
Vistamatic<br />
Chieftain vision<br />
panel 12<br />
01 02 03 04 05 06 07 08 09 10 11 12 13 14<br />
Full frame threshold <br />
Low level threshold w ith stop <br />
Low level threshold <br />
200 mm (w ide) by 300 mm (high)<br />
vision panel formed using Tego S46<br />
glazing units located in the centre<br />
(w idth) of the leaf at a height<br />
betw een 1464.5 and 1614.5 mm up<br />
from the bottom of the leaf.<br />
200 mm (w ide) by 300 mm (high)<br />
vision panel formed using Tego S46<br />
glazing units located betw een the<br />
centre of the leaf and leading<br />
edge 11 at a height betw een 1464.5<br />
and 1614.5 mm up from the bottom<br />
of the leaf.<br />
40.5 mm thick vision panels of<br />
maximum dimensions 400 mm by<br />
400 mm. These may either be<br />
located central to the w idth of the<br />
leaf or offset from leading edge by<br />
150 mm.<br />
27.8 mm thick vision panels of<br />
maximum dimensions 400 mm by<br />
400 mm. These may either be<br />
located central to the w idth of the<br />
leaf or offset from leading edge by<br />
150 mm.<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
20 Nov 2011 373
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
AB26 vision<br />
panel<br />
27 mm thick vision panels of<br />
maximum dimensions 400 mm by<br />
400 mm. These may either be<br />
located central to the w idth of the<br />
leaf or offset from leading edge by<br />
150 mm.<br />
<br />
<br />
Tecdur vision<br />
panel<br />
200 mm (w ide) by 300 mm (high)<br />
vision panel formed using Tecdur<br />
DC49MS glazing units incorporating<br />
steel grids located in the centre<br />
(w idth) of the leaf at a height<br />
betw een 1464.5 and 1614.5 mm<br />
from the bottom of the leaf to the<br />
centre of the vision panel.<br />
<br />
<br />
ExcluVent 3<br />
louvre panels<br />
400 mm (w ide) by 400 mm (high)<br />
louvre panels located central to the<br />
w idth of the leaf in the top half of<br />
the leaf, in the bottom half of the<br />
leaf, or in both top and bottom half’s<br />
of the leaf.<br />
<br />
<br />
ExcluVent 4<br />
louvre panels<br />
400 mm (w ide) by 400 mm (high)<br />
louvre panels located central to the<br />
w idth of the leaf in the top half of<br />
the leaf, in the bottom half of the<br />
leaf, or in both top and bottom half’s<br />
of the leaf.<br />
<br />
<br />
ExcluVent 5<br />
louvre panels<br />
400 mm (w ide) by 400 mm (high)<br />
louvre panels located central to the<br />
w idth of the leaf in the top half of<br />
the leaf, in the bottom half of the<br />
leaf, or in both top and bottom half’s<br />
of the leaf.<br />
<br />
The following table confirms which combinations of vision panel, louvre panel, threshold and locking system may be used together.<br />
Accessory<br />
ExcluVent 3<br />
louvre panel<br />
located in the<br />
top half of the<br />
leaf<br />
ExcluDoor 3 Mk2 doorset ExecDoor 2<br />
doorset<br />
Full Frame<br />
Threshold<br />
Low Level<br />
Threshold<br />
With Stop<br />
Low Level<br />
Threshold<br />
1 to 53 1 to 53 1 to 11, 13,<br />
16 to 18, 22<br />
to 29, 32 to<br />
42, 44 to 48,<br />
50 to 53<br />
Com patible locking systems<br />
ExcluDoor 4 ExcluDoor 4 ExcluDoor 5<br />
Mk2 Mk2 F.R. doorset Mk3<br />
doorset and with any<br />
w ith any ExcluDoor 3 threshold<br />
threshold Mk3 F.R.<br />
option doorsets<br />
w ith any<br />
threshold<br />
option<br />
N/A N/A N/A N/A N/A<br />
ExcluDoor 4<br />
doorset<br />
with any<br />
option 14 threshold<br />
option<br />
374 20 Nov 2011
ExcluVent 3<br />
louvre panel<br />
located in the<br />
bottom half of<br />
the leaf<br />
ExcluVent 3<br />
louvre panels<br />
located in the<br />
top and bottom<br />
halves of the<br />
leaf<br />
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
1 to 53 1 to 53 1 to 53 N/A N/A N/A N/A N/A<br />
1 to 11, 13,<br />
16 to 18, 22<br />
to 29, 32 to<br />
42, 44 to 48,<br />
50 to 53<br />
1 to 11, 13,<br />
16 to 18, 22<br />
to 29, 32 to<br />
42, 44 to 48,<br />
50 to 53<br />
1 to 11, 13,<br />
16 to 18, 22<br />
to 29, 32 to<br />
42, 44 to 48,<br />
50 to 53<br />
ExcluVent 4 N/A N/A N/A N/A 52, 53, 63 to<br />
louvre panels 15 80<br />
N/A N/A N/A N/A N/A<br />
N/A N/A N/A<br />
ExcluVent 5 N/A N/A N/A N/A N/A N/A 52, 53, 83,<br />
louvre panels 15 86, 89, 92,<br />
97, 102<br />
Central and<br />
Offset Tego<br />
vision panels<br />
Vistamatic<br />
Sherman vision<br />
panel<br />
Vistamatic<br />
Chieftain vision<br />
panel<br />
AB26 vision<br />
panel<br />
Tecdur vision<br />
panel<br />
52, 53, 83,<br />
86, 89, 92,<br />
97, 102<br />
1 to 53 1 to 53 1 to 11, 13,<br />
16 to 18, 22<br />
to 29, 32 to<br />
42, 44 to 48,<br />
50 to 53<br />
N/A N/A N/A N/A N/A<br />
N/A N/A N/A 54 to 62 N/A N/A N/A N/A<br />
N/A N/A N/A 54, 56, 62 N/A N/A N/A N/A<br />
N/A N/A N/A 54 to 62 N/A N/A N/A N/A<br />
N/A N/A N/A N/A 52, 53, 63 to<br />
80<br />
N/A N/A N/A<br />
Notes:<br />
1. The ExcluDoor 3 Mk2 double leaf doorset can be produced with leafs of unequal width. The maximum width of both leaves is 1173.5<br />
mm. The minimum width of active leaves approved is 615 mm. The minimum width of passive leaves approved is 300 mm (plain<br />
leaves) and 500 mm (leaves incorporating vision panels).<br />
2. The ExecDoor 2 double leaf doorsets may incorporate leafs of equal or unequal width. Leafs of unequal width will comprise of an<br />
active leaf exactly twice as wide as the passive leaf. The maximum leaf width is 1350 mm and the minimum leaf width is 500 mm.<br />
3. The ExcluDoor 4 Mk2, ExcluDoor 4 Mk2 F.R. and ExcluDoor 3 Mk3 F.R. double leaf doorsets can be produced with leafs of equal<br />
and unequal width, with the leaf width being within the following range:<br />
a. Active leaf width between 615 mm and 1169.5 mm (excluding the astragal).<br />
b. Passive leaf width between 220.5 mm and 1714 mm (excluding the astragal).<br />
4. The ExcluDoor 5 and ExcluDoor 4 Mk3 double leaf doorsets can be produced with leafs of equal and unequal width, with the leaf<br />
width being within the following range:<br />
a. Active leaf width between 615 mm and 1169.5 mm (excluding the astragal).<br />
b. Passive leaf width between 470 mm and 1714 mm (excluding the astragal).<br />
5. Fail secure version only.<br />
6. The resistance of the access control locks to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175.<br />
Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any<br />
access control equipment that may be used to operate these locking systems. This is because the scope of access control devices<br />
and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that Sunray<br />
Engineering satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or<br />
that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may<br />
cause the locking system to disengage.<br />
7. Although outside the scope of LPS 1175: Issue 7, special consideration should be paid to the use of locking systems with separate<br />
deadlocks, e.g. Mico 942-3 INT MD. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a<br />
panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or exit device. For further<br />
information, please refer to the appropriate standards for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125<br />
respectively.<br />
8. Locking systems 58, 59 and 60 may not comply with fire escape regulations relating to potential panic situations if fitted to double leaf<br />
doorsets. This is because activation of the device on one leaf may not necessarily release the other leaf and in some cases may not<br />
release the leaf to which it is fitted.<br />
9. This locking system may only be used on the passive leaf and then only if locking systems 58, 59 and 60 are used on the active leaf.<br />
10. A ‘Plus’ rating demonstrates that the cylinder meets the requirements defined in Annex A of BS 3621: 2007 or manipulation<br />
resistance class ‘1’ defined in LPS 1242: Issue 2.<br />
11. The resistance of the mechatronic cylinders to “non-mechanical” attack has not been assessed as it is outside the scope of LPS<br />
1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of<br />
20 Nov 2011 375
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
ancillary equipment that may be used in conjunction with those cylinders. It is therefore recommended that specifiers satisfy<br />
themselves that the components used are either resistant to electronic methods of attack, or that they are suitably protected from<br />
such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to<br />
disengage.<br />
12. The horizontal position of the offset vision panels depends on the locking hardware fitted. Please refer to the manufacturer for more<br />
details.<br />
13. The Vistamatic vision panels incorporate obscurable panels controlled by a handle on the protected side of the doorset.<br />
14. The ExcluDoor 5 double leaf doorsets incorporating ExcluVent 5 louvre panels achieve Security Rating 4 when placed in the<br />
minimum locked condition and incorporating locking systems 92, 97 and 102 on the active leaf and locking system 52 on the passive<br />
leaf. All other ExcluDoor 5 double leaf doorsets incorporating ExcluVent 5 louvre panels achieve Security Rating 5 when placed in the<br />
minimum locked condition.<br />
15. The ExcluVent 4 and ExcluVent 5 louvre panels were compatible with the locking options listed when the louvre panels were located<br />
in the top half of the leaf only, the bottom half of the leaf only, or in both the top and bottom halves of the leaf.<br />
Technocover Limited (incorporating TechnoRail and Strataform)<br />
Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom<br />
Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527<br />
E-mail: techadvice@technocover.co.uk • Website: www.technocover.co.uk<br />
Certificate No: 450a to LPS 1175: Issue 5<br />
Hinged Security Doorsets<br />
Product Name Type Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
UltraSecure DS1/DV4 Single leaf hinged<br />
outward opening<br />
security doorset<br />
UltraSecure DS2/DV4 Double leaf hinged<br />
outward opening<br />
security doorset<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert. No.<br />
0.9 2.9 0.5 1.3 4 450a/03<br />
0.9 2.9 1.2 2.6 4 450a/08<br />
Compatible Locks<br />
Padlock Designation<br />
Cylinder<br />
UltraSecure Doorset (LPCB<br />
Ref. No. 450a/……)<br />
03 08<br />
Abloy PL240/25 Abloy High profile <br />
Abloy PL240/25EX Abloy Exec <br />
Abloy PL240/25DP Abloy Disklock Pro <br />
Abloy PL240/25PT Abloy Protec <br />
Abloy PL242 Abloy High Profile <br />
Abloy PL242EX Abloy Exec <br />
Abloy PL242DP Abloy Disklock Pro <br />
Abloy PL242PT Abloy Protec <br />
Abloy PL250/25 Abloy High Profile <br />
Abloy PL250/25EX Abloy Exec <br />
Abloy PL250/25DP Abloy Disklock Pro <br />
Abloy PL250/25 Abloy High Profile <br />
Abloy PL250/25 Abloy High Profile <br />
Abloy PL250/25EX Abloy Exec <br />
376 20 Nov 2011
Abloy PL250/25DP Abloy Disklock Pro <br />
Abloy PL250/25PT Abloy Protec <br />
Abloy PL340 Abloy High Profile <br />
Abloy PL340EX Abloy Exec <br />
Abloy PL340DP Abloy Disklock Pro <br />
Abloy PL340PT Abloy Protec <br />
Abloy PL342 Abloy High Profile <br />
Abloy PL342EX Abloy Exec <br />
Abloy PL342DP Abloy Disklock Pro <br />
Abloy PL342PT Abloy Protec <br />
Abloy PL350/25 Abloy High Profile <br />
Abloy PL350/25EX Abloy Exec <br />
Abloy PL350/25DP Abloy Disklock Pro <br />
Abloy PL350/25PT Abloy Protec <br />
Chubb 1K23c Chubb 6-pin cylinder <br />
Kaba KP15.0000C5-RB Kaba 20 (Armoured) 3 <br />
Kaba K20SS65L Kaba 20 (Armoured) 3 <br />
Kaba K20SS65CL Kaba 20 (Armoured) 3 <br />
Kaba Thorlock 4 Kaba 20 <br />
Rotalok 60/12/SE Kaba 20 (Armoured) 3 <br />
Rotalok 60/12/SE Kaba 20 (Standard) 3 <br />
Rotalok 60/12/ST Abloy Disklock Pro <br />
Rotalok 60/12/ST Abloy Exec <br />
Rotalok 60/12/ST Abloy Protec <br />
Rotalok 60/12/ST-T027 Assa Twin-Combi <br />
Rotalok 60/12/ST Kaba 20 (Armoured) 3 <br />
Rotalok 60/12/ST Kaba 20 (Standard) 3 <br />
Accessories<br />
Accessory<br />
UltraSecure Doorset<br />
(LPCB Ref. No. 450a/……)<br />
03 08<br />
Arched profile <br />
K1 staple 4 <br />
Louver option 1 <br />
Louver option 2 <br />
Narrow frame <br />
Shallow threshold <br />
Notes<br />
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
1. Certification does not cover the use of padlocks other than those listed above. Utilisation of unlisted padlocks and/or accessories<br />
may affect the level of security offered by the door set.<br />
2. The ‘user friendliness’ of employing the padlocks listed above has not been assessed as this is beyond the scope of LPS 1175:<br />
Issue 5.<br />
3. The torque resistant version of the Kaba 20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders.<br />
4. K1 staple is used in conjunction with the Kaba Thorlock fitted with a Kaba 20 cylinder.<br />
5. The use of the locking override system is outside the scope of the LPCB approval.<br />
Certificate No: 450d to LPS 1175: Issue 5<br />
Hinged Security Doorsets<br />
Product Name Type Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Ultra Secure DS1/DV3 Single leaf hinged<br />
outward opening<br />
security doorset<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert. No.<br />
0.9 2.9 0.5 1.3 3 450d/01<br />
20 Nov 2011 377
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Product Name Type Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Ultra Secure DS1/LS3 Single leaf hinged<br />
outward opening<br />
security doorset<br />
Ultra Secure DS2/DV3 Double leaf hinged<br />
outward opening<br />
security doorset<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert. No.<br />
0.9 2.3 0.5 1.1 3 450d/02<br />
0.9 2.9 1.2 2.6 3 450d/03<br />
Compatible locking devices<br />
Locking Device Type<br />
Cylinder<br />
Ultra Secure Doorsets<br />
(LPCB Ref. No. 450d/..)<br />
01 02 03<br />
Abloy PL240/25 Padlock Abloy High Profile <br />
Abloy PL240/25EX Padlock Abloy Exec <br />
Abloy PL240/25DP Padlock Abloy Disklock Pro <br />
Abloy PL240/25PT Padlock Abloy Protec <br />
Abloy PL242 Padlock Abloy High Profile <br />
Abloy PL242EX Padlock Abloy Exec <br />
Abloy PL242DP Padlock Abloy Disklock Pro <br />
Abloy PL242PT Padlock Abloy Protec <br />
Abloy PL250/25 Padlock Abloy High Profile <br />
Abloy PL250/25EX Padlock Abloy Exec <br />
Abloy PL250/25DP Padlock Abloy Disklock Pro <br />
Abloy PL250/25PT Padlock Abloy Protec <br />
Abloy PL340 Padlock Abloy High Profile <br />
Abloy PL340EX Padlock Abloy Exec <br />
Abloy PL340DP Padlock Abloy Disklock Pro <br />
Abloy PL340PT Padlock Abloy Protec <br />
Abloy PL342 Padlock Abloy High Profile <br />
Abloy PL342EX Padlock Abloy Exec <br />
Abloy PL342DP Padlock Abloy Disklock Pro <br />
Abloy PL342PT Padlock Abloy Protec <br />
Abloy PL350/25 Padlock Abloy High Profile <br />
Abloy PL350/25EX Padlock Abloy Exec <br />
Abloy PL350/25DP Padlock Abloy Disklock Pro <br />
Abloy PL350/25PT Padlock Abloy Protec <br />
Chubb 1K23c Padlock Chubb 6-pin cylinder <br />
Kaba KP15.0000C5-RB Padlock Kaba 20 (Armoured) 3 <br />
Kaba K20SS65L Padlock Kaba 20 (Armoured) 3 <br />
378 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Kaba K20SS65CL Padlock Kaba 20 (Armoured) 3 <br />
Kaba Thorlock 4 Integral lock Kaba 20 (Armoured) 3 <br />
Kaba Thorlock 4 Integral lock Kaba 20 (Standard) 3 <br />
Rotalok 60/12/SE Padlock Kaba 20 (Armoured) 3 <br />
Rotalok 60/12/SE Padlock Kaba 20 (Standard) 3 <br />
Rotalok 60/12/ST Padlock Abloy Disklock Pro <br />
Rotalok 60/12/ST Padlock Abloy Exec <br />
Rotalok 60/12/ST Padlock Abloy Protec <br />
Rotalok 60/12/ST-T027 Padlock Assa Twin-Combi <br />
Rotalok 60/12/ST Padlock Kaba 20 (Armoured) 3 <br />
Rotalok 60/12/ST Padlock Kaba 20 (Standard) 3 <br />
Surelock McGill DL800 Single point surface<br />
mounted locking<br />
device with cylinder<br />
deadlock operated by<br />
key (outside) and turn<br />
knob (inside) with<br />
integrated S-10319<br />
cylinder guard<br />
ASSA Flexicore F523<br />
<br />
Surelock McGill DL800<br />
Single point surface<br />
mounted locking<br />
device with cylinder<br />
deadlock operated by<br />
key (outside) and turn<br />
knob (inside) with<br />
integrated S-10319<br />
cylinder guard<br />
ASSA 4823<br />
<br />
Surelock McGill DL800<br />
Single point surface<br />
mounted locking<br />
device with cylinder<br />
deadlock operated by<br />
key (outside) and turn<br />
knob (inside) with<br />
integrated S-10319<br />
cylinder guard<br />
ASSA Twin Combi<br />
F5823<br />
<br />
Surelock McGill DL800<br />
Single point surface<br />
mounted locking<br />
device with cylinder<br />
deadlock operated by<br />
key (outside) and turn<br />
knob (inside) with<br />
integrated S-10319<br />
cylinder guard<br />
Abloy Disklok Pro<br />
CY303<br />
<br />
20 Nov 2011 379
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Surelock McGill DL800<br />
Single point surface<br />
mounted locking<br />
device with cylinder<br />
deadlock operated by<br />
key (outside) and turn<br />
knob (inside) with<br />
integrated S-10319<br />
cylinder guard<br />
Kaba QS152.100.00<br />
<br />
Surelock McGill DL800<br />
Single point surface<br />
mounted locking<br />
device with cylinder<br />
deadlock operated by<br />
key (outside) and turn<br />
knob (inside) with<br />
integrated S-10319<br />
cylinder guard<br />
Union 2X20A<br />
<br />
Notes<br />
1. Certification does not cover the use of locks other than those listed above. Utilisation of unlisted locks may<br />
affect the level of security offered by the door set.<br />
2. The ‘user friendliness’ of employing the padlocks listed above has not been assessed as this is beyond<br />
the scope of LPS 1175: Issue 5.<br />
3. The torque resistant version of the Kaba 20 cylinder must be fitted to these padlocks in place of the standard<br />
Kaba 20 cylinders.<br />
4. Certification only covers the galvanised mild steel versions.<br />
Certificate No: 450f to LPS 1175: Issue 7<br />
Hinged Security Doorsets<br />
Product Name Doorset Configuration Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Sentinel UltraSecure Single leaf outward<br />
opening hinged<br />
security doorset<br />
Double 1 leaf outward<br />
opening hinged<br />
security doorset<br />
Single leaf outward<br />
opening hinged<br />
security doorset<br />
Double 1 leaf outward<br />
opening hinged<br />
security doorset<br />
Single leaf outward<br />
opening hinged<br />
security doorset<br />
Double 1 leaf outward<br />
opening hinged<br />
security doorset<br />
Single leaf outward<br />
opening hinged<br />
security doorset<br />
Double leaf outward<br />
opening hinged<br />
security doorset<br />
Single leaf outward<br />
opening hinged<br />
security doorset<br />
Double leaf outward<br />
opening hinged<br />
security doorset<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Cert. No.<br />
1.8 2.35 0.75 1.2 3 450f/01<br />
1.8 2.35 1.2 2.185 3 2 450f/02<br />
1.8 2.35 0.75 1.2 4 450f/03<br />
1.8 2.35 1.2 2.185 4 450f/04<br />
1.8 2.35 0.75 1.2 5 450f/05<br />
1.8 2.35 1.2 2.3 5 450f/06<br />
1.7 2.35 0.75 1.2 3 450f/07<br />
1.7 2.35 1.2 2.35 3 2 450f/08<br />
1.7 2.35 0.75 1.2 4 450f/09<br />
1.7 2.35 1.2 2.35 4 450f/10<br />
380 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
Approved Locking Configurations<br />
LPCB Ref. Trade Name Type Compatible Locking Systems<br />
No.<br />
450f/01 Sentinel<br />
UltraSecure<br />
Single leaf outward opening<br />
hinged security doorset<br />
SM1 to SM5, SM11 to SM15 and SM21 to<br />
SM25<br />
450f/02 Sentinel<br />
UltraSecure<br />
Double leaf outward opening<br />
hinged security doorset<br />
SM1 to SM5, SM11 to SM15 and SM21 to<br />
SM25<br />
450f/03 Sentinel<br />
UltraSecure<br />
Single leaf outward opening<br />
hinged security doorset<br />
SM6 to SM10, SM16 to SM20 and SM26<br />
to SM30<br />
450f/04 Sentinel<br />
UltraSecure<br />
Double leaf outward opening<br />
hinged security doorset<br />
SM6 to SM10, SM16 to SM20 and SM26<br />
to SM30<br />
450f/05 Sentinel<br />
UltraSecure<br />
Single leaf outward opening<br />
hinged security doorset<br />
MT21 to MT30, MT51 to MT60 and MT81<br />
to MT90<br />
450f/06 Sentinel<br />
UltraSecure<br />
Double1 leaf outward opening<br />
hinged security doorset<br />
MT22, MT24, MT26, MT28, MT30, MT52,<br />
MT54, MT56, MT58, MT60, MT82, MT84,<br />
MT86, MT88, MT90<br />
450f/07 Sentinel<br />
UltraSecure<br />
Single leaf outward opening<br />
hinged security doorset<br />
MT1 to MT10, MT31 to MT40 and MT61 to<br />
MT70<br />
450f/08 Sentinel<br />
UltraSecure<br />
Double leaf outward opening<br />
hinged security doorset<br />
MT1(T) to MT10(T), MT31(T) to MT40(T)<br />
and MT61(T) to MT70(T)<br />
450f/09 Sentinel<br />
UltraSecure<br />
Single leaf outward opening<br />
hinged security doorset<br />
MT11 to MT20, MT41 to MT50 and MT71<br />
to MT80<br />
450f/10 Sentinel<br />
UltraSecure<br />
Compatible Locking Systems<br />
Double leaf outward opening<br />
hinged security doorset<br />
MT12(T), MT14(T), MT16(T), MT18(T),<br />
MT20(T), MT42(T), MT44(T), MT46(T),<br />
MT48(T), MT50(T), MT72(T), MT74(T),<br />
MT76(T), MT78(T), MT80(T)<br />
Compatible<br />
Locking System<br />
SM1<br />
SM2<br />
SM3<br />
SM4<br />
Manufacturer Operating Devices Compatible<br />
Active Leaf<br />
Passive Leaf Cylinders<br />
Surelock McGill<br />
Limited<br />
Surelock McGill<br />
Limited<br />
Surelock McGill<br />
Limited<br />
Surelock McGill<br />
Limited<br />
Model External Face Internal Face<br />
EX800-K2-Q4-P-<br />
(04/05) single<br />
point emergency<br />
exit device<br />
DL800-Q4-P-<br />
(04/05) single<br />
point lock<br />
SL315-H3-P-A5-<br />
(04/05) three point<br />
emergency exit<br />
device<br />
SL314-P-A5-<br />
(04/05) three point<br />
panic exit device<br />
Key and lever<br />
handle<br />
Key and lever<br />
handle<br />
Key and lever<br />
handle<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Thumb turn and<br />
lever handle<br />
Single action<br />
push pad<br />
Panic bar<br />
Two S3TB barrel<br />
bolts<br />
Two S3TB barrel<br />
bolts<br />
Two S3TB barrel<br />
bolts<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
AH, AM, AN,<br />
AO, AP<br />
AH, AM, AN,<br />
AO, AP<br />
AH, AM, AN,<br />
AO, AP<br />
SM5<br />
Surelock McGill<br />
Limited<br />
AC800-K2-K4-P-R-<br />
(04/05) single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with break<br />
dome thumb turn<br />
override and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM6<br />
Surelock McGill<br />
Limited<br />
SL315-P5-A5-<br />
(04/05) three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
20 Nov 2011 381
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
SM7<br />
Surelock McGill<br />
Limited<br />
SL313-P5-A5-K15-<br />
(04/05) three point<br />
locking system<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM8<br />
SM9<br />
Surelock McGill<br />
Limited<br />
Surelock McGill<br />
Limited<br />
SL315-H3-P5-A5-<br />
(04/05) three point<br />
emergency exit<br />
device<br />
SL314-P5-A5-<br />
(04/05) three point<br />
panic exit device<br />
Key and lever<br />
handle<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Panic bar<br />
Two S3TB barrel<br />
bolts<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
AH, AM, AN,<br />
AO, AP<br />
SM10<br />
Surelock McGill<br />
Limited<br />
SL322-P5-A5-K2-<br />
K4-(04/05) three<br />
point locking<br />
system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with break<br />
dome thumb turn<br />
override and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM11<br />
Surelock McGill<br />
Limited<br />
AC800-K2-P-Q4-R-<br />
X-(04/05) single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM12<br />
Surelock McGill<br />
Limited<br />
AC800-K2-K9-P-<br />
Q4-R-(04/05)<br />
single point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM13<br />
Surelock McGill<br />
Limited<br />
SL325-H3-P-K2-<br />
A5-R-(04/05) three<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM14<br />
Surelock McGill<br />
Limited<br />
SL324-P-A5-K2-R-<br />
(04/05) three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM15<br />
Surelock McGill<br />
Limited<br />
AC800-K2-K4-P-R-<br />
(04/05) single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with break<br />
dome thumb turn<br />
override and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
382 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
SM16<br />
Surelock McGill<br />
Limited<br />
SL325-P5-K2-A5-<br />
R-(04/05) three<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM17<br />
Surelock McGill<br />
Limited<br />
SL323-P5-K2-K15-<br />
A5-R-(04/05) three<br />
point locking<br />
system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM18<br />
Surelock McGill<br />
Limited<br />
SL325-H3-P5-K2-<br />
A5-R-(04/05) three<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM19<br />
Surelock McGill<br />
Limited<br />
SL324-P5-A5-K2-<br />
R-(04/05) three<br />
point panic exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM20<br />
Surelock McGill<br />
Limited<br />
SL322-P5-A5-K2-<br />
K4-(04/05) three<br />
point locking<br />
system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with break<br />
dome thumb turn<br />
override and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
AH, AM, AN,<br />
AO, AP<br />
SM21<br />
Surelock McGill<br />
Limited<br />
EX800-Q4-(04/05)<br />
single point<br />
emergency exit<br />
device<br />
None<br />
Single action<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
Not applicable<br />
SM22<br />
Surelock McGill<br />
Limited<br />
DL800-Q4-(04/05)<br />
single point lock<br />
None<br />
Thumb turn and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
Not applicable<br />
SM23<br />
SM24<br />
Surelock McGill<br />
Limited<br />
Surelock McGill<br />
Limited<br />
SL315-H3-A5-<br />
(04/05) three point<br />
emergency exit<br />
device<br />
SL314-A5-(04/05)<br />
three point panic<br />
exit device<br />
None<br />
Single action<br />
push pad<br />
Two S3TB barrel<br />
bolts<br />
None Panic bar Two S3TB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
20 Nov 2011 383
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
SM25<br />
Surelock McGill<br />
Limited<br />
AC800-K4-R-<br />
(04/05) single<br />
point lock 3 None Electromechanical<br />
access control<br />
lock (fail secure)<br />
with break dome<br />
thumb turn<br />
override and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
Not applicable<br />
SM26<br />
SM27<br />
Surelock McGill<br />
Limited<br />
Surelock McGill<br />
Limited<br />
SL315-A5-(04/05)<br />
three point<br />
emergency exit<br />
device<br />
SL313-O0-A5-K15-<br />
(04/05) three point<br />
locking system<br />
None<br />
None<br />
Single action<br />
lever handle<br />
Thumb turn and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
Two S3TB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
SM28<br />
SM29<br />
Surelock McGill<br />
Limited<br />
Surelock McGill<br />
Limited<br />
SL315-H3-A5-<br />
(04/05) three point<br />
emergency exit<br />
device<br />
SL314-A5-(04/05)<br />
three point panic<br />
exit device<br />
None<br />
Single action<br />
push pad<br />
Two S3TB barrel<br />
bolts<br />
None Panic bar Two S3TB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
SM30<br />
Surelock McGill<br />
Limited<br />
SL322-A5-K4-<br />
(04/05) three point<br />
locking system 3 None Electromechanical<br />
access control<br />
lock (fail secure)<br />
with break dome<br />
thumb turn<br />
override and<br />
lever handle<br />
Two S3TB barrel<br />
bolts<br />
Not applicable<br />
MT1<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 4 SATE<br />
USCH3 single<br />
point emergency<br />
exit device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT1<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 4 SATE<br />
EPC USCH3<br />
single point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT1(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 4 SATE<br />
USCH3 single<br />
point emergency<br />
exit device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
384 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT1(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 4 SATE<br />
EPC USCH3<br />
single point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT2<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
SATE<br />
USCH3three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT2<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
SATE EPC<br />
USCH3 three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT2(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
SATE USCH3<br />
three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
MT2(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
SATE EPC<br />
USCH3 three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT3<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 3<br />
USCH3 single<br />
point lock<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT3<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 3 EPC<br />
USCH3 single<br />
point lock<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT3(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 3<br />
USCH3 single<br />
point lock<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
MT3(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 3 EPC<br />
USCH3 single<br />
point lock<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT4<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
USCH3 three point<br />
locking system<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT4<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
EPC USCH3 three<br />
point locking<br />
system<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT4(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
USCH3 three point<br />
locking system<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
20 Nov 2011 385
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT4(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
EPC USCH3 three<br />
point locking<br />
system<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT5<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 1 SATE<br />
USCH3 single<br />
point emergency<br />
exit device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT5<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 1 SATE<br />
EPC USCH3<br />
single point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT5(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 1 SATE<br />
USCH3 single<br />
point emergency<br />
exit device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
A to M And AH<br />
to AN<br />
MT5(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 1 SATE<br />
EPC USCH3<br />
single point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT6<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P INT AD<br />
SATE USCH3<br />
three point<br />
emergency exit<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
device<br />
MT6<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P INT AD<br />
SATE EPC<br />
USCH3three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT6(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P INT AD<br />
SATE<br />
USCH3three point<br />
emergency exit<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
device<br />
MT6(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P INT AD<br />
SATE EPC<br />
USCH3 three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT7<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 2 SATE<br />
USCH3 single<br />
point panic exit<br />
device<br />
Key and lever<br />
handle<br />
Panic bar Not applicable A to M and AH<br />
to AN<br />
MT7<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 2 SATE<br />
EPC USCH3<br />
single point panic<br />
exit device<br />
Key and lever<br />
handle<br />
Panic bar Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT7(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 2 SATE<br />
USCH3 single<br />
point panic exit<br />
device<br />
Key and lever<br />
handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
386 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT7(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 2 SATE<br />
EPC USCH3<br />
single point panic<br />
exit device<br />
Key and lever<br />
handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT8<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 INT AD<br />
SATE USCH3<br />
three point panic<br />
Key and lever<br />
handle<br />
Panic bar Not applicable A to M and AH<br />
to AN<br />
exit device<br />
MT8<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 INT AD<br />
SATE EPC<br />
USCH3 three point<br />
panic exit device<br />
Key and lever<br />
handle<br />
Panic bar Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT8(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 INT AD<br />
SATE USCH3<br />
three point panic<br />
Key and lever<br />
handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
exit device<br />
MT8(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 INT AD<br />
SATE EPC<br />
USCH3 three point<br />
panic exit device<br />
Key and lever<br />
handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT9<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure)<br />
USCH3 single<br />
point lock 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT9<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure) EPC<br />
USCH3 single<br />
point lock 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT9(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure)<br />
USCH3 single<br />
point lock 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
MT9(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure) EPC<br />
USCH3 single<br />
point lock 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
20 Nov 2011 387
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT10<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) USCH3<br />
three point locking<br />
system 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT10<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) EPC<br />
USCH3 three point<br />
locking system 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT10(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) USCH3<br />
three point locking<br />
system 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
MT10(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) EPC<br />
USCH3 three point<br />
locking system 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT11<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 4 SATE<br />
USCH4 single<br />
point emergency<br />
exit device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT11<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 4 SATE<br />
EPC USCH4<br />
single point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT12<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
SATE USCH4<br />
three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT12<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
SATE EPC<br />
USCH4 three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT12(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
SATE USCH4<br />
three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
388 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT12(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
SATE EPC<br />
USCH4 three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT13<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 3 SATE<br />
USCH4 single<br />
point lock<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT13<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 3 SATE<br />
EPC USCH4<br />
single point lock<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT14<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
USCH4 three point<br />
locking system<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT14<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
EPC USCH4 three<br />
point locking<br />
system<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT14(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
USCH4 three point<br />
locking system<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT14(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
EPC USCH4 three<br />
point locking<br />
system<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT15<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 1 SATE<br />
USCH4 single<br />
point emergency<br />
exit device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT15<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 1 SATE<br />
EPC USCH4<br />
single point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT16<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P INT AD<br />
SATE USCH4<br />
three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT16<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P INT AD<br />
SATE EPC<br />
USCH4 three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT16(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P INT AD<br />
SATE USCH4<br />
three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
20 Nov 2011 389
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT16(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P INT AD<br />
SATE EPC<br />
USCH4 three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT17<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 2 SATE<br />
USCH4 single<br />
point panic exit<br />
device<br />
Key and lever<br />
handle<br />
Panic bar Not applicable B to M and AH<br />
to AN<br />
MT17<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD 2 SATE<br />
EPC USCH4<br />
single point panic<br />
exit device<br />
Key and lever<br />
handle<br />
Panic bar Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT18<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 INT AD<br />
SATE USCH4<br />
three point panic<br />
exit device<br />
Key and lever<br />
handle<br />
Panic bar Not applicable B to M and AH<br />
to AN<br />
MT18<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 INT AD<br />
SATE EPC<br />
USCH4 three point<br />
panic exit device<br />
Key and lever<br />
handle<br />
Panic bar Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT18(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 INT AD<br />
SATE USCH4<br />
three point panic<br />
exit device<br />
Key and lever<br />
handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT18(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 INT AD<br />
SATE EPC<br />
USCH4 three point<br />
panic exit device<br />
Key and lever<br />
handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT19<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure)<br />
USCH4 single<br />
point lock 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT19<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure) EPC<br />
USCH4 single<br />
point lock 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
390 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT20<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) USCH4<br />
three point locking<br />
system 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT20<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) EPC<br />
USCH4 three point<br />
locking system 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT20(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) USCH4<br />
three point locking<br />
system 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT20(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) EPC<br />
USCH4 three point<br />
locking system 3<br />
Key and lever<br />
handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT21<br />
MT21<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD3 SATE<br />
USCH5 single<br />
point emergency<br />
exit device<br />
Abryll AD3 SATE<br />
EPC USCH5<br />
single point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Single action<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT22<br />
Tindall<br />
Engineering<br />
Limited<br />
942L INT AD<br />
SATE USCH5<br />
three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT22<br />
Tindall<br />
Engineering<br />
Limited<br />
942L INT AD<br />
SATE EPC<br />
USCH5 three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT23<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD3 USCH5<br />
single point lock<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
20 Nov 2011 391
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT23<br />
MT24<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD3 EPC<br />
USCH5 single<br />
point lock<br />
942L INT AD<br />
USCH5 three point<br />
locking system<br />
Key and lever<br />
handle<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT24<br />
Tindall<br />
Engineering<br />
Limited<br />
942L INT AD EPC<br />
USCH5 three point<br />
locking system<br />
Key and lever<br />
handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT25<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD1 SATE<br />
USCH5 single<br />
point emergency<br />
exit device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT25<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD1 SATE<br />
EPC USCH5<br />
single point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT26<br />
Tindall<br />
Engineering<br />
Limited<br />
942P INT AD<br />
SATE USCH5<br />
three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT26<br />
Tindall<br />
Engineering<br />
Limited<br />
942P INT AD<br />
SATE EPC<br />
USCH5 three point<br />
emergency exit<br />
device<br />
Key and lever<br />
handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT27<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD2 SATE<br />
USCH5 single<br />
point panic exit<br />
device<br />
Key and lever<br />
handle<br />
Panic bar Not applicable B to M and AH<br />
to AN<br />
MT27<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll AD2 SATE<br />
EPC USCH5<br />
single point panic<br />
exit device<br />
Key and lever<br />
handle<br />
Panic bar Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT28<br />
Tindall<br />
Engineering<br />
Limited<br />
942 INT AD SATE<br />
USCH5 three point<br />
panic exit device<br />
Key and lever<br />
handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT28<br />
Tindall<br />
Engineering<br />
Limited<br />
942 INT AD SATE<br />
EPC USCH5 three<br />
point panic exit<br />
device<br />
Key and lever<br />
handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT29<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM3<br />
(fail secure)<br />
USCH5 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
392 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT29<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM3<br />
(fail secure) EPC<br />
USCH5 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT30<br />
Tindall<br />
Engineering<br />
Limited<br />
942L EM<br />
(fail secure)<br />
USCH5 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT30<br />
Tindall<br />
Engineering<br />
Limited<br />
942L EM<br />
(fail secure) EPC<br />
USCH5 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT31<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 4 SATE<br />
(fail secure)<br />
USCH3 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT31<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 4 SATE<br />
(fail secure) EPC<br />
USCH3 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT31(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 4 SATE<br />
(fail secure)<br />
USCH3 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
20 Nov 2011 393
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT31(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 4 SATE<br />
(fail secure) EPC<br />
USCH3 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT32<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM SATE<br />
(fail secure)<br />
USCH3 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT32<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM SATE<br />
(fail secure) EPC<br />
USCH3 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT32(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM SATE<br />
(fail secure)<br />
USCH3 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
MT32(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM SATE<br />
(fail secure) EPC<br />
USCH3 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT33<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 3 SATE<br />
(fail secure)<br />
USCH3 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
394 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT33<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 3 SATE<br />
(fail secure) EPC<br />
USCH3 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT33(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 3 SATE<br />
(fail secure)<br />
USCH3 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
MT33(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 3 SATE<br />
(fail secure) EPC<br />
USCH3 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT34<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM<br />
(fail secure)<br />
USCH3 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT34<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM<br />
(fail secure) EPC<br />
USCH3 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT34(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM<br />
(fail secure)<br />
USCH3 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
20 Nov 2011 395
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT34(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM<br />
(fail secure) EPC<br />
USCH3 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT35<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1 SATE<br />
(fail secure)<br />
USCH3 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT35<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1 SATE<br />
(fail secure) EPC<br />
USCH3 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT35(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1 SATE<br />
(fail secure)<br />
USCH3 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
MT35(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1 SATE<br />
(fail secure) EPC<br />
USCH3 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT36<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P EM SATE<br />
(fail secure)<br />
USCH3 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
396 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT36<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P EM SATE<br />
(fail secure) EPC<br />
USCH3 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT36(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P EM SATE<br />
(fail secure)<br />
USCH3 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
MT36(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P EM SATE<br />
(fail secure) EPC<br />
USCH3 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT37<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 2 SATE<br />
(fail secure)<br />
USCH3 single<br />
point panic exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar Not applicable A to M and AH<br />
to AN<br />
MT37<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 2 SATE<br />
(fail secure) EPC<br />
USCH3 single<br />
point panic exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT37(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 2 SATE<br />
(fail secure)<br />
USCH3 single<br />
point panic exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
20 Nov 2011 397
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT37(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 2 SATE<br />
(fail secure) EPC<br />
USCH3 single<br />
point panic exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT38<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 EM SATE<br />
(fail secure)<br />
USCH3 three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar Not applicable A to M and AH<br />
to AN<br />
MT38<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 EM SATE<br />
(fail secure) EPC<br />
USCH3 three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT38(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 EM SATE<br />
(fail secure)<br />
USCH3 three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
MT38(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 EM SATE<br />
(fail secure) EPC<br />
USCH3 three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT39<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure)<br />
USCH3 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
398 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT39<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure) EPC<br />
USCH3 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT39(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure)<br />
USCH3 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
MT39(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure)EPC<br />
USCH3 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT40<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) USCH3<br />
three point locking<br />
system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
A to M and AH<br />
to AN<br />
MT40<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) EPC<br />
USCH3 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT40(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) USCH3<br />
three point locking<br />
system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
A to M and AH<br />
to AN<br />
20 Nov 2011 399
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT40(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) EPC<br />
USCH3 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT41<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 4 SATE<br />
(fail secure)<br />
USCH4 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT41<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 4 SATE<br />
(fail secure) EPC<br />
USCH4 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT42<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM SATE<br />
(fail secure)<br />
USCH4 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT42<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM SATE<br />
(fail secure) EPC<br />
USCH4 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT42(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM SATE<br />
(fail secure)<br />
USCH4 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
400 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT42(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM SATE<br />
(fail secure) EPC<br />
USCH4 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT43<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 3 SATE<br />
(fail secure)<br />
USCH4 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT43<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 3 SATE<br />
(fail secure) EPC<br />
USCH4 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT44<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM<br />
(fail secure)<br />
USCH4 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT44<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM<br />
(fail secure) EPC<br />
USCH4 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT44(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM SATE<br />
(fail secure)<br />
USCH4 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
20 Nov 2011 401
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT44(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM SATE<br />
(fail secure) EPC<br />
USCH4 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT45<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1 SATE<br />
(fail secure)<br />
USCH4 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT45<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1 SATE<br />
(fail secure) EPC<br />
USCH4 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT46<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P EM SATE<br />
(fail secure)<br />
USCH4 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT46<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P EM SATE<br />
(fail secure) EPC<br />
USCH4 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT46(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P EM SATE<br />
(fail secure)<br />
USCH4 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
402 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT46(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P EM SATE<br />
(fail secure) EPC<br />
USCH4 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT47<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 2 SATE<br />
(fail secure)<br />
USCH4 single<br />
point panic exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar Not applicable B to M and AH<br />
to AN<br />
MT47<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 2 SATE<br />
(fail secure) EPC<br />
USCH4 single<br />
point panic exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT48<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 EM SATE<br />
(fail secure)<br />
USCH4 three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar Not applicable B to M and AH<br />
to AN<br />
MT48<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 EM SATE<br />
(fail secure) EPC<br />
USCH4 three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT48(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 EM SATE<br />
(fail secure)<br />
USCH4 three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
20 Nov 2011 403
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT48(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3 EM SATE<br />
(fail secure) EPC<br />
USCH4 three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT49<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure)<br />
USCH4 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT49<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure) EPC<br />
USCH4 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT50<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) USCH4<br />
three point locking<br />
system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT50<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) EPC<br />
USCH4 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT50(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) USCH4<br />
three point locking<br />
system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
404 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT53<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM3<br />
(fail secure) EPC<br />
USCH5 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT54<br />
Tindall<br />
Engineering<br />
Limited<br />
942L EM<br />
(fail secure)<br />
USCH5 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT54<br />
Tindall<br />
Engineering<br />
Limited<br />
942L EM<br />
(fail secure) EPC<br />
USCH5 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT55<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM1 SATE<br />
(fail secure)<br />
USCH5 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
MT55<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM1 SATE<br />
(fail secure) EPC<br />
USCH5 single<br />
point emergency<br />
exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT56<br />
Tindall<br />
Engineering<br />
Limited<br />
942P EM SATE<br />
(fail secure)<br />
USCH5 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
20 Nov 2011 405
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT56<br />
Tindall<br />
Engineering<br />
Limited<br />
942P EM SATE<br />
(fail secure) EPC<br />
USCH5 three point<br />
emergency exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT57<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM2 SATE<br />
(fail secure)<br />
USCH5 single<br />
point panic exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar Not applicable B to M and AH<br />
to AN<br />
MT57<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM2 SATE<br />
(fail secure) EPC<br />
USCH5 single<br />
point panic exit<br />
device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar Not applicable N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT58<br />
Tindall<br />
Engineering<br />
Limited<br />
942 EM SATE<br />
(fail secure)<br />
USCH5 three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT58<br />
Tindall<br />
Engineering<br />
Limited<br />
942 EM SATE<br />
(fail secure) EPC<br />
USCH5 three point<br />
panic exit device 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Panic bar<br />
Two HSTB barrel<br />
bolts<br />
N, Q, T, V, X, Z,<br />
AB, AD, AF<br />
MT59<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM3<br />
(fail secure)<br />
USCH5 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
B to M and AH<br />
to AN<br />
406 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT59<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM3<br />
(fail secure) EPC<br />
USCH5 single<br />
point lock 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Not applicable O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT60<br />
Tindall<br />
Engineering<br />
Limited<br />
942L EM<br />
(fail secure)<br />
USCH5 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
B to M and AH<br />
to AN<br />
MT60<br />
Tindall<br />
Engineering<br />
Limited<br />
942L EM<br />
(fail secure) EPC<br />
USCH5 three point<br />
locking system 3<br />
Electromechanical<br />
access control<br />
lock (fail secure)<br />
with key override<br />
and lever handle<br />
Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
O, P, R, S, U,<br />
W, Y, AA, AC,<br />
AE, AG<br />
MT61<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll PE 4 SATE<br />
single point<br />
emergency exit<br />
device<br />
None<br />
Single action<br />
lever handle<br />
Not applicable<br />
Not applicable<br />
MT61(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll PE 4 SATE<br />
single point<br />
emergency exit<br />
device<br />
None<br />
Single action<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
MT62<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L three point<br />
emergency exit<br />
device<br />
None<br />
Single action<br />
lever handle<br />
Not applicable<br />
Not applicable<br />
MT62(T)<br />
MT63<br />
MT63(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L three point<br />
emergency exit<br />
device<br />
Abryll AD 3 SATE<br />
single point lock<br />
Abryll AD 3 SATE<br />
single point lock<br />
None<br />
None<br />
None<br />
Single action<br />
lever handle<br />
Thumb turn and<br />
lever handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
MT64<br />
MT64(T)<br />
MT65<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
three point locking<br />
system<br />
942-3L INT AD<br />
three point locking<br />
system<br />
Abryll PE 1 SATE<br />
single point<br />
emergency exit<br />
device<br />
None<br />
None<br />
None<br />
Thumb turn and<br />
lever handle<br />
Thumb turn and<br />
lever handle<br />
Single action<br />
push pad<br />
Not applicable<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
MT65(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll PE 1 SATE<br />
single point<br />
emergency exit<br />
device<br />
None<br />
Single action<br />
push pad<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
MT66<br />
MT66(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P three point<br />
emergency exit<br />
device<br />
942-3P three point<br />
emergency exit<br />
device<br />
None<br />
None<br />
Single action<br />
push pad<br />
Single action<br />
push pad<br />
Not applicable<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
20 Nov 2011 407
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT67<br />
MT67(T)<br />
MT68<br />
MT68(T)<br />
MT69<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll PE 2 SATE<br />
single point panic<br />
exit device<br />
Abryll PE 2 SATE<br />
single point panic<br />
exit device<br />
942-3 three point<br />
panic exit device<br />
942-3 three point<br />
panic exit device<br />
None Panic bar Not applicable Not applicable<br />
None Panic bar Two HSTB barrel<br />
bolts<br />
Not applicable<br />
None Panic bar Not applicable Not applicable<br />
None Panic bar Two HSTB barrel<br />
bolts<br />
Abryll EM 1<br />
(fail secure) single<br />
point lock 3 None Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
MT69(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll EM 1<br />
(fail secure) single<br />
point lock 3 None Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
MT70<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) three point<br />
locking system 3 None Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
Not applicable<br />
MT70(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) three point<br />
locking system 3 None Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
MT71<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll PE 4 SATE<br />
single point<br />
emergency exit<br />
device<br />
None<br />
Single action<br />
lever handle<br />
Not applicable<br />
Not applicable<br />
MT72<br />
MT72(T)<br />
MT73<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L three point<br />
emergency exit<br />
device<br />
942-3L three point<br />
emergency exit<br />
device<br />
Abryll AD 3 SATE<br />
single point lock<br />
None<br />
None<br />
None<br />
Single action<br />
lever handle<br />
Single action<br />
lever handle<br />
Thumb turn and<br />
lever handle<br />
Not applicable<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
408 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT74<br />
MT74(T)<br />
MT75<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L INT AD<br />
three point locking<br />
system<br />
942-3L INT AD<br />
three point locking<br />
system<br />
Abryll PE 1 single<br />
point emergency<br />
exit device<br />
None<br />
None<br />
None<br />
Thumb turn and<br />
lever handle<br />
Thumb turn and<br />
lever handle<br />
Single action<br />
push pad<br />
Not applicable<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
MT76<br />
MT76(T)<br />
MT77<br />
MT78<br />
MT78(T)<br />
MT79<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3P three point<br />
emergency exit<br />
device<br />
942-3P three point<br />
emergency exit<br />
device<br />
Abryll PE 2 single<br />
point panic exit<br />
device<br />
942-3 three point<br />
panic exit device<br />
942-3 three point<br />
panic exit device<br />
None<br />
None<br />
Single action<br />
push pad<br />
Single action<br />
push pad<br />
Not applicable<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
None Panic bar Not applicable Not applicable<br />
None Panic bar Not applicable Not applicable<br />
None Panic bar Two HSTB barrel<br />
bolts<br />
Abryll EM 1<br />
(fail secure) single<br />
point lock 3 None Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
MT80<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) three point<br />
locking system 3 None Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
Not applicable<br />
MT80(T)<br />
Tindall<br />
Engineering<br />
Limited<br />
942-3L EM (fail<br />
secure) three point<br />
locking system 3 None Electromechanical<br />
access control<br />
lock with<br />
shrouded thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
MT81<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll PE3 single<br />
point emergency<br />
exit device<br />
None<br />
Single action<br />
lever handle<br />
Not applicable<br />
Not applicable<br />
MT82<br />
MT83<br />
MT84<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
942L three point<br />
emergency exit<br />
device<br />
Abryll AD3 single<br />
point lock<br />
942L INT AD three<br />
point locking<br />
system<br />
None<br />
None<br />
None<br />
Single action<br />
lever handle<br />
Thumb turn and<br />
lever handle<br />
Thumb turn and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
20 Nov 2011 409
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
MT85<br />
MT86<br />
MT87<br />
MT88<br />
MT89<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Tindall<br />
Engineering<br />
Limited<br />
Abryll PE1 single<br />
point emergency<br />
exit device<br />
942P three point<br />
emergency exit<br />
device<br />
Abryll PE2 single<br />
point panic exit<br />
device<br />
942 three point<br />
panic exit device<br />
None<br />
None<br />
Single action<br />
push pad<br />
Single action<br />
push pad<br />
Not applicable<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Not applicable<br />
None Panic bar Not applicable Not applicable<br />
None Panic bar Two HSTB barrel<br />
bolts<br />
Abryll EM3<br />
(fail secure) single<br />
point lock 3 None Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Not applicable<br />
Not applicable<br />
Not applicable<br />
MT90<br />
Tindall<br />
Engineering<br />
Limited<br />
942L EM<br />
(fail secure) three<br />
point locking<br />
system 3 None Electromechanical<br />
access control<br />
lock with thumb<br />
turn override and<br />
lever handle<br />
Two HSTB barrel<br />
bolts<br />
Not applicable<br />
Compatible Cylinders<br />
Cylinder Manufacturer Model Type<br />
Reference<br />
A Abloy Disklock Pro CY201 DP Scandinavian Oval (with tail)<br />
B Abloy Protec CY201 PT Scandinavian Oval (with tail)<br />
C Abloy Protec Cliq CY201 Scandinavian Oval (with tail) (Electo-mechanical)<br />
D AMS CL-OVLD 3 Scandinavian Oval (with tail) (Electo-mechanical)<br />
E ASSA 4407dp Scandinavian Oval (with tail)<br />
F ASSA 4407 Cliq Scandinavian Oval (with tail) (Electo-mechanical)<br />
G ASSA 4807 Scandinavian Oval (with tail)<br />
H ASSA C5807 Scandinavian Oval (with tail)<br />
I ASSA Twin 7607 Scandinavian Oval (with tail)<br />
J Kaba K20 Scandinavian Oval (with tail)<br />
K Kaba Quattro PluS Scandinavian Oval (with tail)<br />
L Locken CL-PL2WR 3 Scandinavian Oval (with tail) (Electo-mechanical)<br />
M Medeco M3-ARX Scandinavian Oval (with tail)<br />
N Abloy Protec CY304 Europrofile double cylinder (key:key)<br />
O Abloy Protec Cliq CY333 Europrofile double cylinder (key:thumbturn) (Electomechanical)<br />
P Abloy Protec CY333 Europrofile double cylinder (key:thumbturn)<br />
Q Abloy Protec Cliq CY304 Europrofile double cylinder (key:key) (Electo-mechanical)<br />
R Abloy Protec CY305 Europrofile double cylinder (key:thumbturn)<br />
S Abloy Protec Cliq CY305 Europrofile double cylinder (key:thumbturn) (Electomechanical)<br />
410 20 Nov 2011
PART 4: SECTION 5.1.1<br />
HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES<br />
T ASSA 4422dp Europrofile double cylinder (key:key)<br />
U ASSA 4427dp Europrofile double cylinder (key:thumbturn)<br />
V ASSA 44M22 Cliq Europrofile double cylinder (key:key) (Electo-mechanical)<br />
W ASSA 44M27 Cliq Europrofile double cylinder (key:thumbturn) (Electomechanical)<br />
X ASSA 4822 Europrofile double cylinder (key:key)<br />
Y ASSA 4827 Europrofile double cylinder (key:thumbturn)<br />
Z ASSA C5822 Europrofile double cylinder (key:key)<br />
AA ASSA C5827 Europrofile double cylinder (key:thumbturn)<br />
AB ASSA 7622 Europrofile double cylinder (key:key)<br />
AC ASSA 7627 Europrofile double cylinder (key:thumbturn)<br />
AD Kaba Quattro PluS Europrofile double cylinder (key:key)<br />
AE Kaba Quattro PluS Europrofile double cylinder (key:thumbturn)<br />
AF Medeco M3-ARX Europrofile double cylinder (key:key)<br />
AG Medeco M3-ARX Europrofile double cylinder (key:thumbturn)<br />
AH Abloy Protec CY403 Rim<br />
AI Abloy Protec Cliq CY403 Rim(Electo-mechanical)<br />
AJ Kaba Quattro Plus Rim<br />
AK Medeco M3-ARX Rim<br />
AL AMS CL-CA2D 3 Finish Round (Electo-mechanical)<br />
AM ASSA 4857 Round threaded<br />
AN ASSA C5857 Round threaded<br />
AO Kaba KV06.100 (torque Rim<br />
resistant)<br />
AP Yale PK1109 (Pro key) Rim<br />
Options<br />
Option<br />
Upper louver vent (200 mm by 220<br />
mm)<br />
Lower louver vent (200 mm by 220<br />
mm)<br />
Compatible Locking Systems<br />
SM1 to SM30,<br />
MT1 to MT20 and MT1(T) to MT20(T),<br />
MT31 to MT50 and MT31(T) to MT 50(T),<br />
MT61 to MT80 and MT61(T) to MT80(T)<br />
SM1, SM2, SM3, SM5, SM6, SM7, SM8, SM10, SM11, SM12, SM13, SM15, SM16, SM17, SM18,<br />
SM20, SM21, SM22, SM23, SM25, SM26, SM27, SM28, SM30, MT1, MT1(T), MT2, MT2(T), MT3,<br />
MT3(T), MT4, MT4(T), MT5, MT5(T), MT6, MT6(T), MT9, MT9(T), MT10, MT10(T), MT11, MT12,<br />
MT12(T), MT13, MT14, MT14(T), MT15, MT16, MT16(T), MT19, MT20, MT20(T), MT31, MT31(T),<br />
MT32, MT32(T), MT33, MT33(T), MT34, MT34(T), MT35, MT35(T), MT36, MT36(T), MT39, MT39(T),<br />
MT40, MT40(T), MT41, MT42, MT42(T), MT43, MT44, MT44(T), MT45, MT46, MT46(T), MT49, MT50,<br />
MT50(T), MT61, MT61(T), MT62, MT62(T), MT63, MT63(T), MT64, MT64(T), MT65, MT65(T), MT66,<br />
MT66(T), MT69, MT69(T), MT70, MT70(T), MT71, MT72, MT72(T), MT73, MT74, MT74(T), MT75,<br />
MT76, MT76(T), MT79, MT80, MT80(T)<br />
Notes:<br />
1<br />
This approval covers double leaf doorsets with:<br />
<br />
<br />
Leafs of equal width (450f/02, 450f/04 and 450f/06); and<br />
Leafs of unequal width (450f/02 and 450f/04). Both leafs on these doors shall be between 300 mm and 975 mm wide.<br />
2 If only one barrel bolt on the passive leaf is engaged on configurations SM3, SM4, SM13, SM14, SM23, SM24, MT1(T) to MT10(T),<br />
MT31(T) to MT40(T) and MT61(T) to MT70(T), these configurations achieve Security Rating 1. Both barrel bolts must therefore be<br />
engaged to ensure that the doorsets meet the requirements of Security Rating 3.<br />
3 The resistance of the access control locks and electro-mechanical cylinders to “non-mechanical” attack is not covered by this approval<br />
as they were outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the<br />
functionality and performance of any access control equipment that may be used to operate these locking systems. This is because the<br />
scope of access control devices and system configurations that may be used with these locking systems is “infinite”. It is therefore<br />
recommended that specifiers’ satisfy themselves that the components used are either resistant to mechanical and other forms of<br />
tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental<br />
conditions/interference that may cause the locking system to disengage.<br />
20 Nov 2011 411
PART 4: SECTION 5.1.2<br />
HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES<br />
Blyweert Beaufort Aluminium Limited<br />
Imperial Park, Celtic Way, Newport NP10 8BE, United Kingdom<br />
Tel: +44 (0)1633 294040 • Fax: +44 (0)1633 294041<br />
E-mail: sales@blyweertbeaufort.com • Website: www.blyweertbeaufort.com<br />
Certificate No: 975a to LPS 1175: Issue 6<br />
Hinged Security Doorset<br />
Product<br />
Type<br />
Name<br />
'LPS 1175 Single leaf bidirectional<br />
Commercial glazed aluminium doorset with<br />
Door' anti-finger trap hinges and two<br />
deadlocks on the leading<br />
edge<br />
Minimum Maximum Minimum Maximum Security Cert.<br />
Height (m) Height (m) Width (m) Width (m) Rating No.<br />
1.8 <strong>2.2</strong> 0.9 1.2 2 1 975a/01<br />
Compatible Locking System<br />
Manufacturer Model Type Compatible Cylinders<br />
Adams Rite Sentinel 6 Deadlock fitted w ith the Adams<br />
Rite Sentinel security<br />
escutcheon and lock face plate<br />
Manufacturer Model Type<br />
Adams Rite<br />
CL1-ED3535-SC-KD Double europrofile<br />
cylinder (key:key)<br />
Compatible Glazing Material<br />
Manufacturer Model Type<br />
Hamilton Erskine TECDUR SR2/SR3 DGU 28 mm thick double glazing unit<br />
Notes:<br />
1. The doorset achieves Security Rating 2 in the optimum locked condition, i.e. when both locks are engaged. A Security Rating 1<br />
classification is achieved when only one lock is engaged.<br />
2. The quality of work conducted by those fabricating and installing the doorset can affect the products’ ability to offer resistance to<br />
forced entry commensurate with that of the Security Rating attributed to the doorset. It is therefore recommended that the doorset is<br />
sourced from fabricators that hold LPCB approval for the fabrication of this doorset.<br />
Bradbury Security<br />
Dunlop Way, Queensway Industrial Estate, Scunthorpe DN16 3RN, United Kingdom<br />
Tel: +44 (0)1724 271999 • Fax: +44 (0)1724 271888<br />
E-mail: sales@bradburyuk.com • Website: www.bradburyuk.com<br />
Certificate No: 312e to LPS 1175: Issue 7<br />
Hinged Security Doorsets<br />
Product<br />
Name<br />
Product<br />
Type<br />
Minimum<br />
Structural<br />
Opening Height<br />
(m)<br />
M2M3<br />
Combat<br />
Single leaf<br />
outward<br />
opening<br />
doorset<br />
Double leaf<br />
outward<br />
opening<br />
doorset<br />
Maximum<br />
Structural<br />
Opening Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.745 2.43 0.74 1.18 3 312e/01<br />
1.745 2.43 1.15 <strong>2.2</strong>0 3 312e/02<br />
412 20 Nov 2011
PART 4: SECTION 5.1.2<br />
HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES<br />
Product<br />
Name<br />
M2M3<br />
Substation<br />
Product<br />
Type<br />
Single leaf<br />
outward<br />
opening<br />
doorset<br />
Double leaf<br />
outward<br />
opening<br />
doorset<br />
Minimum<br />
Structural<br />
Opening Height<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.745 2.43 0.74 1.18 3 312e/03<br />
1.745 2.43 1.15 <strong>2.2</strong>0 3 312e/04<br />
Note<br />
1. Refer to Volume 2 Part 4 Section 5.1.1 for full details of the sizes, locking devices and accessories approved on the M2M3 doorset<br />
ranges.<br />
C W Fields and Son Limited<br />
Station Road Industrial Estate, Epworth, Nr. Doncaster, South Yorkshire DN9 1JZ, United Kingdom<br />
Tel: +44 (0)1427 872368 • Fax: +44 (0)1427 873057<br />
E-mail: info@cwfields.co.uk • Website: www.cwfields.co.uk<br />
Certificate No: 940a to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product<br />
Name<br />
Type<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
Fields Security Single leaf outward opening hinged security doorset 2 940a/01<br />
Single leaf outward opening hinged security doorset with fixed/removable over<br />
2 940a/02<br />
panels<br />
Single leaf inward opening hinged security doorset 2 940a/03<br />
Single leaf inward opening hinged security doorset with fixed/removable over panels 2 940a/04<br />
Double leaf outward opening hinged security doorset 2 940a/05<br />
Double leaf outward opening hinged security doorset with fixed/removable over<br />
2 940a/06<br />
panels<br />
Double leaf inward opening hinged security doorset 2 940a/07<br />
Double leaf inward opening hinged security doorset with fixed/removable over<br />
panels<br />
2 940a/08<br />
Note:<br />
1. Refer to Volume 2 Part 4 Section 5.1.1 for full details of the sizes, locking systems and accessories approved on the Fields Security<br />
doorset range.<br />
Design & Supply Limited<br />
13 Pant Industrial Estate, Merthyr Tydfil, Mid Glamorgan CF48 2SR, United Kingdom<br />
Tel: +44 (0)1685 350114 • Fax: +44 (0)1685 723276<br />
E-mail: dsl@designandsupply.co.uk<br />
Certificate No: 694b to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product<br />
Name<br />
Type<br />
Minimum<br />
Structural<br />
Opening Height<br />
(m)<br />
Desray Single leaf<br />
outward<br />
opening hinged<br />
security doorset<br />
Maximum<br />
Structural<br />
Opening Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.8 <strong>2.2</strong> 0.75 1.3 2 694b/01<br />
20 Nov 2011 413
PART 4: SECTION 5.1.2<br />
HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES<br />
Product<br />
Name<br />
Type<br />
Double leaf<br />
outward<br />
opening hinged<br />
security doorset<br />
Minimum<br />
Structural<br />
Opening Height<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.8 <strong>2.2</strong> 1.5 2.5 2 694b/02<br />
Note<br />
1. Refer to Volume 2 Part 4 Section 5.1.1 for full details of the locking systems and accessories approved on the Desray doorsets.<br />
Fendor Limited<br />
Heworth House, William Street, Felling, Gateshead NE10 0JP, United Kingdom<br />
Tel: +44 (0)191 438 3222 • Fax: +44 (0)191 438 1686<br />
E-mail: av@fendor.co.uk • Website: www.fendor.co.uk<br />
Certificate No: 712b to LPS 1175: Issue 5<br />
Hinged Security Doorsets<br />
Product<br />
Type<br />
Name<br />
SecureLine<br />
Single leaf outward opening<br />
hinged security doorsets<br />
Single leaf inward opening hinged<br />
security doorsets<br />
Double leaf outward opening<br />
hinged security doorsets<br />
Double leaf inward opening<br />
hinged security doorsets<br />
Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
2.0 2.6 0.85 1.4 2 712b/01<br />
2.0 2.6 0.85 1.4 2<br />
2.0 2.6 1.5 2.8 2<br />
2.0 <strong>2.2</strong>4 1.5 2.8 2<br />
Compatible Locking Devices and Glazing<br />
LPCB Product<br />
Ref. No. Name<br />
712b/01 SecureLine<br />
Notes<br />
Type Lock Cylinder Glazing 2<br />
Single leaf outw ard<br />
opening hinged<br />
security doorsets<br />
Single leaf inw ard<br />
opening hinged<br />
security doorsets<br />
Double leaf outw ard<br />
opening hinged<br />
security doorsets<br />
Double leaf inw ard<br />
opening hinged<br />
security doorsets<br />
Adams Rite MS2000 maximum<br />
security deadlock model 2200-<br />
210 w ith barbolt<br />
Adams Rite MS2000 maximum<br />
security deadlock model 2200-<br />
210 w ith barbolt<br />
Adams Rite MS2000 maximum<br />
security deadlock model 2200-<br />
250 w ith hookbolt and<br />
top/bottom rods<br />
Adams Rite MS2000 maximum<br />
security deadlock model 2200-<br />
250 w ith hookbolt and<br />
top/bottom rods<br />
Assa Sofi 4822<br />
Europrofile double<br />
cylinder (key:key)<br />
Assa Sofi 4822<br />
Europrofile double<br />
cylinder (key:key)<br />
Assa Sofi 4822<br />
Europrofile double<br />
cylinder (key:key)<br />
Assa Sofi 4822<br />
Europrofile double<br />
cylinder (key:key)<br />
16 mm thick specialist<br />
laminated glazing unit<br />
16 mm thick specialist<br />
laminated glazing unit<br />
16 mm thick specialist<br />
laminated glazing unit<br />
16 mm thick specialist<br />
laminated glazing unit<br />
1. The SecureLine doorsets should be mounted within the reveal, directly into the surrounding structure in accordance with Fendor<br />
Hansen installation instructions SR2+/03.<br />
2. Alternative glazing may not provide equivalent resistance to attack. Therefore, please consult Fendor Hansen before replacing or<br />
changing the glazing.<br />
414 20 Nov 2011
PART 4: SECTION 5.1.2<br />
HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES<br />
Liddle Doors Limited<br />
Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom<br />
Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698<br />
E-mail: liddle@liddledoors.co.uk • Website: www.liddledoors.co.uk<br />
Certificate No: 442b to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product<br />
Type<br />
Name<br />
Liddle Single leaf outward<br />
Series 3 opening hinged<br />
doorset<br />
Double leaf outward<br />
opening hinged<br />
doorset<br />
Minimum<br />
Height (m)<br />
Maximum<br />
Height (m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.8 <strong>2.2</strong> 0.75 1.2 3 442b/01<br />
1.8 <strong>2.2</strong> 1.4 2.0 3 442b/02<br />
Vision Panels<br />
Note<br />
Product Name Vision Panels Compatible Doorset Configurations<br />
Single Leaf Outward Opening Double Leaf Outward Opening<br />
Liddle Series 3 200 mm wide by 40 mm high<br />
vision panel<br />
<br />
<br />
1. Refer to Volume 2 Part 4 Section 5.1.1 for full details of the locking systems approved on the Liddle Series 3 doorsets.<br />
MultiSteel Limited<br />
MultiSteel House, 117-119 Brent Terrace, London NW2 1LL, United Kingdom<br />
Tel: +44 (0)20 8208 8300 • Fax: +44 (0)20 8208 8209<br />
E-mail: office@multisteel.co.uk • Website: www.multisteel.co.uk<br />
Certificate No: 818a to LPS 1175: Issue 6<br />
Hinged Security Doorsets<br />
Product<br />
Name<br />
Type Minimum<br />
Height (m)<br />
Multisteel<br />
'Mag Lock'<br />
Multisteel '3<br />
Point Mul-T-<br />
Lock'<br />
Maximum<br />
Height (m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Compatible<br />
Locking<br />
Systems<br />
Security<br />
Rating<br />
Single leaf<br />
outward<br />
opening<br />
doorset 1, 2 1.83 2.43 0.647 1.377 1 1 818a/01<br />
Single leaf 1.83 2.43 0.575 1.425 2 2 818a/02<br />
doorset 1, 2<br />
outward<br />
opening<br />
Cert.<br />
No.<br />
Compatible Locking Systems<br />
20 Nov 2011 415
PART 4: SECTION 5.1.2<br />
HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES<br />
Locking<br />
Locking System Operating Devices Compatible<br />
System Manufacturer Model Type External Face Internal Face Cylinders<br />
Reference 1 Securitron Magnalock M32<br />
(top of leaf) and<br />
M32c (bottom of<br />
leaf)<br />
Pair of<br />
electromagnetic<br />
locks<br />
‘Entrotec low rise<br />
panel with DDA<br />
features’ access<br />
control panel with<br />
PAC panel reader<br />
(PAC20085) 3<br />
‘Entrotec DDA<br />
push to exit’ push<br />
button release 4<br />
Not applicable<br />
2 Mul-T-Lock 235 Multipoint mortise<br />
lock<br />
Key and lever<br />
handle<br />
Key and lever<br />
handle<br />
A or B<br />
Compatible Cylinders<br />
Cylinder Reference Manufacturer Model Type<br />
A Mul-T-Lock Garrison Double euro-profile cylinder (key:key)<br />
B Mul-T-Lock Interactive Double euro-profile cylinder (key:key)<br />
Notes<br />
1. The doorsets may be used within the walling systems falling within the scope of the ‘Multisteel security screen’ modular<br />
security screen walling system (LPCB certificate reference 818b/01), for example, to form communal entrance systems.<br />
2. The doorsets are available with either glazed or opaque panels.<br />
3. The access control system’s resistance to “non-mechanical” attack has not been assessed as it is outside the scope of<br />
LPS 1175. It is therefore recommended that specifiers satisfy themselves that the components used are resistant to any<br />
environmental conditions/interference that may cause the locking system to disengage.<br />
4. The push button must be located at least 1.5 m from the doorset and any associated side and over panels.<br />
Stafford Bridge Doors Limited<br />
Bedford Road, Pavenham, Bedford MK43 7PS, United Kingdom<br />
Tel: +44 (0)1234 826316 • Fax: +44 (0)1234 826319<br />
E-mail: sales@sbdoors.com • Website: www.surelockmcgillgroup.com/sbd<br />
Certificate No: 516a to LPS 1175: Issue 5<br />
Hinged Doorsets<br />
Product<br />
Name<br />
Sandhurst<br />
Hendon<br />
Sandhurst<br />
Type<br />
Single leaf, outward and<br />
inward opening hinged<br />
security doorset<br />
Single leaf, outward and<br />
inward opening hinged<br />
security doorset<br />
Double leaf, outward<br />
opening hinged security<br />
doorset<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.9 2.5 0.7 1 3 516a/01<br />
1.9 2.5 0.7 1 2 516a/02<br />
1.9 2.5 1.4 2 3 516a/05<br />
Note<br />
1. Refer to Volume 2 Part 4 Section 5.1.1 for full details of the locking systems and accessories approved on the Sandhurst and<br />
Hendon doorsets.<br />
416 20 Nov 2011
PART 4: SECTION 5.1.2<br />
HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES<br />
Sunray Engineering Limited<br />
Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL, United Kingdom<br />
Tel: +44 (0)1233 639039 • Fax: +44 (0)1233 625137<br />
E-mail: sales@sunraydoors.co.uk • Website: www.sunraydoors.co.uk<br />
Certificate No: 234d to LPS 1175: Issue 7<br />
Hinged Security Doorsets<br />
Product<br />
Type<br />
Name<br />
ExcluDoor 3<br />
Mk2<br />
ExecDoor 2<br />
ExcluDoor 4<br />
Mk2<br />
Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Single leaf, outward opening hinged 1.8 2.4 0.75 1.24 3 234d/01<br />
security doorset with vision panel<br />
Double leaf, outward opening hinged<br />
security doorset with vision panel<br />
1.8 2.4 1.24 2.4 3 234d/02<br />
Single leaf, outward opening hinged 1.8 <strong>2.2</strong> 0.75 1.3 2 234d/03<br />
security doorset with vision panel<br />
Double leaf, outward opening hinged 1.8 <strong>2.2</strong> 1.5 2.5 2 234d/04<br />
security doorset with vision panel<br />
Single leaf, outward opening hinged 1.8 2.4 0.75 1.24 4 234d/05<br />
security doorset with vision panel<br />
doorset with vision panel 1.8 2.4 1.24 2.4 4 234d/06<br />
Cert.<br />
No.<br />
Note:<br />
1. Refer to Volume 2 Part 4 Section 5.1.1 for full details of the locking systems and accessories approved on the ExecDoor 2, ExcluDoor<br />
3 Mk2 and ExcluDoor 4 Mk2 doorsets.<br />
20 Nov 2011 417
PART 4: SECTION 5.1.3<br />
HIGH SECURITY HINGED DOORSETS WITH OTHER LEAF DESIGNS<br />
Lowrey Contractors Limited<br />
200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom<br />
Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111<br />
E-mail: lowrey@talk21.com • Website: www.lowrey-contractors.co.uk<br />
Certificate No: 974a to LPS 1175: Issue 7<br />
Hinged Mesh Panel Security Doorsets<br />
Product Name Type Minimum<br />
Height (m)<br />
Lowrey Level 1<br />
Single Leaf Mesh<br />
Security Doorset<br />
Lowrey Level 1<br />
Double Leaf Mesh<br />
Security Doorset<br />
Lowrey Level 2<br />
Single Leaf Mesh<br />
Security Doorset<br />
Lowrey Level 2<br />
Double Leaf Mesh<br />
Security Doorset<br />
Lowrey Level 3<br />
Single Leaf Mesh<br />
Security Doorset<br />
Lowrey Level 3<br />
Double Leaf Mesh<br />
Security Doorset<br />
Single leaf outward<br />
opening mesh<br />
panel doorset<br />
Double leaf<br />
outward opening<br />
mesh panel<br />
doorset<br />
Single leaf outward<br />
opening mesh<br />
panel doorset<br />
Double leaf<br />
outward opening<br />
mesh panel<br />
doorset<br />
Single leaf outward<br />
opening mesh<br />
panel doorset<br />
Double leaf<br />
outward opening<br />
mesh panel<br />
doorset<br />
Maximum Minimum Maximum Security Cert.<br />
Height (m) Width (m) Width (m) Rating No.<br />
1.0 2.4 0.6 1.3 1 974a/01<br />
1.0 2.4 1.2 2.6 1 974a/02<br />
1.0 2.4 0.6 1.3 2 974a/03<br />
1.0 2.4 1.2 2.6 2 974a/04<br />
1.0 2.4 0.6 1.3 3 974a/05<br />
1.0 2.4 1.2 2.6 3 974a/06<br />
Compatible Locking Devices 1, 2 01 02 03 04 05 06<br />
Manufacture Locking Device Type Cylinder Approved Product (LPCB Ref. No. 974a/..)<br />
Abloy Abloy PL330/25 (V01) HP Padlock Abloy High Profile <br />
Abloy Abloy PL330/25 (V01) EX Padlock Abloy Exec <br />
Abloy Abloy PL330/25 (V01) PT Padlock Abloy Protec <br />
Abloy Abloy PL340/25 (V01) HP Padlock Abloy High Profile <br />
Abloy Abloy PL340/25 (V01) EX Padlock Abloy Exec <br />
Abloy Abloy PL340/25 (V01) PT Padlock Protec <br />
Abloy Abloy PL342 (V01) HP Padlock Abloy High Profile <br />
Abloy Abloy PL342 (V01) EX Padlock Abloy Exec <br />
Abloy Abloy PL342 (V01) PT Padlock Abloy Protec <br />
Abloy Abloy PL350/25 (V01) HP Padlock Abloy High Profile <br />
Abloy Abloy PL350/25 (V01) EX Padlock Abloy Exec <br />
Abloy Abloy PL350/25 (V01) PT Padlock Abloy Protec <br />
Kaba<br />
Kaba K18 w ith 11 mm open<br />
shackle (Item No. K180010-SS)<br />
Padlock Kaba K20-C5 <br />
Notes:<br />
1. Certification does not cover the use of locks other than those listed. Utilisation of unlisted locks may affect the level of security offered<br />
by the doorset.<br />
2. The ‘user friendliness’ of employing the padlocks listed has not been assessed as this is beyond the scope of LPS 1175: Issue 7.<br />
3. The Lowrey security mesh doorsets are approved when installed in accordance with the instructions detailed on Lowrey document E-<br />
INST004 (Issue 4).<br />
418 20 Nov 2011
PART 4: SECTION 5.1.3<br />
HIGH SECURITY HINGED DOORSETS WITH OTHER LEAF DESIGNS<br />
Technocover Limited (incorporating TechnoRail and Strataform)<br />
Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom<br />
Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527<br />
E-mail: techadvice@technocover.co.uk • Website: www.technocover.co.uk<br />
Certificate No: 450j to LPS 1175: Issue 7<br />
Hinged Mesh Panel Security Doorset<br />
Product<br />
Name<br />
Product Type Minimum<br />
Height (m)<br />
Maximum<br />
Height (m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
Ultrasecure<br />
SCD1<br />
Single leaf outward<br />
opening mesh panel<br />
1 3 0.5 1.2 3 450j/01<br />
Ultrasecure<br />
SCD2<br />
doorset<br />
Double leaf outward<br />
opening mesh panel<br />
doorset<br />
1 3 1.2 3 3 450j/02<br />
Compatible Locking Devices<br />
Locking Device Type Cylinder Approved Product<br />
(LPCB Ref. No. 450j/..)<br />
01 02<br />
Kaba K18 Padlock Kaba 20 with C5 option <br />
Notes<br />
1. Certification does not cover the use of locks other than those listed above. Utilisation of unlisted locks may affect the<br />
level of security offered by the doorset.<br />
2. The ‘user friendliness’ of employing the padlock listed above has not been assessed as this is beyond the scope of<br />
LPS 1175: Issue 7.<br />
3. The Ultrasecure SCD1 and SCD2 mesh panel doorsets are approved when installed in accordance with the<br />
instructions detailed on document SCD-DV-3-FIT-01 (Ref.A).<br />
20 Nov 2011 419
PART 4: SECTION 5.1.4<br />
HIGH SECURITY FOLDING DOORSETS<br />
Bolton Gate Co. Limited<br />
Waterloo Street, Bolton, Lancashire BL1 2SP, United Kingdom<br />
Tel: +44 (0)1204 871000 • Fax: +44 (0)1204 871049<br />
E-mail: kb@boltongate.co.uk • Website: www.boltongate.co.uk<br />
Certificate No: 026-2b to LPS 1175: Issue 5<br />
Folding Security Doorsets<br />
Product Name Type Number<br />
of Door<br />
Panels<br />
Superfold 4000<br />
Superfold 5000<br />
Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert. No.<br />
Sliding folding panel 4 3.00 1.70 6.00 4.65 4 026-2b/01<br />
security door set 1<br />
Sliding folding panel 6 3.00 2.60 6.00 7.00 4<br />
security door set 1<br />
Sliding folding panel<br />
security door set 1 8 3.00 3.55 6.00 8.00 4<br />
Sliding folding panel 4 3.00 1.70 6.00 4.65 5 026-2b/02<br />
security door set 1<br />
Sliding folding panel 6 3.00 2.60 6.00 7.00 5<br />
security door set<br />
Sliding folding panel 8 3.00 3.55 6.00 8.00 5<br />
security door set<br />
Compatible Locking Devices<br />
LPCB Ref. No. Trade Name<br />
Locking Device<br />
026-2b/01 Superfold 4000 Chubb 7009 padbar and Chubb 1K11 padlock 2<br />
026-2b/02 Superfold 5000 Chubb 7009 padbar and Chubb 1K11 padlock 2<br />
Notes<br />
1. Single stack back configuration only.<br />
2. The locking device is mounted on the "non-attack" face of the doorset. Therefore, although not currently covered by the scope of<br />
the approval, other padlocks may be suitable for use on the doorsets.<br />
420 20 Nov 2011
PART 4: SECTION 5.2.1<br />
DOMESTIC DOORSETS APPROVED TO PAS 23-1<br />
Doorsets listed in this <strong>section</strong> are approved to PAS 23-1 General performance requirements for door<br />
assemblies - Part 1. Single leaf, external door assemblies to dwellings.<br />
This standard describes a series of test methods and a range of criteria relevant to the general performance<br />
of single leaf, single swing, external door assemblies to dwellings. The scope of the standard covers inward<br />
and outward opening doorsets, with or without integral or coupled side panels and fanlights. Where these are<br />
covered by the LPCB certificate, details will be provided in the listing for that product.<br />
The scope of the standard does not cover the installation of the product nor does it cover double leaf doors,<br />
sliding doors, folding doors, tilt and slide doors, and pivoted doors, or doors with any frame member over 3m.<br />
For details of hinged doorsets approved to LPS 1175 and PAS 24-1 please refer to <strong>section</strong>s 5.1 and 5.<strong>2.2</strong><br />
respectively.<br />
IR Martin Roberts, IR Security & Safety Limited<br />
Millen Road, Sittingbourne, Kent ME10 2AA, United Kingdom<br />
Tel: +44 (0)1795 476161 • Fax: +44 (0)1795 422463<br />
E-mail: martin_roberts@eu.irco.com • Website: www.irmartinroberts.co.uk<br />
Certificate No: 322b to PAS23-1: 1999 (Incorporating Amendment No. 1)<br />
Hinged Security Doorsets<br />
Product Type<br />
Name<br />
Martin Roberts<br />
SD5001<br />
Martin Roberts<br />
SD5001(1)<br />
Single leaf,<br />
hinged security<br />
doorsets<br />
Single leaf,<br />
hinged security<br />
doorsets<br />
Direction of<br />
Opening<br />
Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Exposure<br />
Category<br />
Cert.<br />
No.<br />
Outward 0.951 0.503 3.049 1.332 800U 322b/02<br />
Inward 0.951 0.503 <strong>2.2</strong>50 1.332 800U<br />
Compatible Locking Options<br />
LPCB Ref.<br />
No.<br />
Trade Name Type Direction of<br />
Opening<br />
322b/02 Martin Roberts<br />
SD5001<br />
Compatible Locking Systems<br />
Single leaf, hinged<br />
security doorsets<br />
Compatible Locking<br />
Systems<br />
Outward 2<br />
Inward 1<br />
Option Locking Type<br />
Compatible External and Internal Operating Devices<br />
System<br />
External<br />
Internal<br />
1 Assa 1520 Escape Sash Lock Key via an Assa 4801 single<br />
cylinder or<br />
Key via an Assa 4802 double<br />
cylinder<br />
Assa 6650C solid brass<br />
handle plus either<br />
Assa 6256 thumbturn or<br />
Key via an Assa 4802 double<br />
cylinder<br />
Note<br />
2 Assa 8761 Emergency Nightlatch Key via an Assa 4801 single<br />
cylinder<br />
Assa 640 solid brass handle<br />
1. The Martin Roberts SD5001 also meets the requirements of LPS 1175: Issue 5 and PAS 24-1:1999. For further information, please<br />
refer to entries in <strong>section</strong>s on LPS 1175: Issue 5 and PAS 24-1 relating to LPCB certificates 322a and 322c respectively.<br />
20 Nov 2011 421
PART 4: SECTION 5.2.1<br />
DOMESTIC DOORSETS APPROVED TO PAS 23-1<br />
Salisbury Glass Centre Limited<br />
Newton Road, Churchfields Industrial Estate, Salisbury, Wiltshire SP2 7QA, United Kingdom<br />
Tel: +44 (0)1722 342900 • Fax: +44 (0)1722 338784<br />
E-mail: commercialenquiries@salisbury-glass.com or domesticenquiries@salisbury-glass.com • Website:<br />
www.salisbury-glass.com<br />
Certificate No: 947a to PAS 23-1:1999 (incorporating amendments Nos. 1, 2, 3 and 4 and Corrigendum No. 1) and PAS 24:2007<br />
Hinged Doorsets<br />
Product<br />
Type<br />
Name<br />
Visoline<br />
Fully glazed single<br />
leaf outward opening<br />
aluminium doorset<br />
Minimum<br />
Structural<br />
Opening Height<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Width<br />
(m)<br />
Cert.<br />
No.<br />
1.85 <strong>2.2</strong> 0.8 1.05 947a/01<br />
Notes<br />
1. This doorset achieves exposure category '850 Special'.<br />
2. Refer to Volume 2 Part 4 Section 5.<strong>2.2</strong> for full details of the locking systems and compatible cylinders approved on the doorsets.<br />
422 20 Nov 2011
PART 4: SECTION 5.<strong>2.2</strong><br />
DOMESTIC DOORSETS APPROVED TO PAS 24-1<br />
Doorsets listed in this <strong>section</strong> are approved to PAS 24-1 Enhanced security requirements for door assemblies<br />
- Part 1. Single and double leaf, external door assemblies to dwellings.<br />
This standard describes a series of test methods and a range of criteria relevant to the general performance<br />
of single and double leaf, single swing, hinged external door assemblies for dwellings. The scope of the<br />
standard covers inward and outward opening doorsets, with or without integral or coupled side panels and<br />
fanlights. Where these are covered by the LPCB certificate, details will be provided in the listing for that<br />
product.<br />
The scope of the standard does not cover the installation of the product nor does it cover sliding doors, folding<br />
doors, tilt and slide doors, and pivoted doors, or doors with any frame member over 3m.<br />
The concept of ‘enhanced security’ in this product standard is based upon a relationship between forced<br />
human intervention techniques with basic hand tools and resistance to entry under multi-directional loading<br />
and hard and soft body impact tests. The standard provides a means of evaluation of resistance to opportunist<br />
attack. The standard does not provide a means of evaluating the protection provided against unauthorised<br />
intrusion to the levels of attack or scope of entry methods covered within LPS 1175 Requirements and testing<br />
procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security<br />
enclosures and free-standing barriers.<br />
The ability to gain entry by picking the locks, deliberately breaking the glass or by attacking the frame fixing<br />
methods is not addressed in PAS 24-1.<br />
For details of hinged doorsets approved to LPS 1175 and PAS 23-1 please refer to <strong>section</strong>s 5.1 and 5.2<br />
respectively.<br />
IR Martin Roberts, IR Security & Safety Limited<br />
Millen Road, Sittingbourne, Kent ME10 2AA, United Kingdom<br />
Tel: +44 (0)1795 476161 • Fax: +44 (0)1795 422463<br />
E-mail: martin_roberts@eu.irco.com • Website: www.irmartinroberts.co.uk<br />
Certificate No: 322c to PAS24-1: 1999 (Incorporating Amendment No 1)<br />
Hinged Security Doorsets<br />
Product Name Type Direction of<br />
Opening<br />
Martin Roberts<br />
SD5001<br />
Single leaf, hinged<br />
security doorsets<br />
Single leaf, hinged<br />
security doorsets<br />
Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Cert.<br />
No.<br />
Outward 0.951 0.503 3.049 1.332 322c/02<br />
Inward 0.951 0.503 <strong>2.2</strong>50 1.332<br />
20 Nov 2011 423
PART 4: SECTION 5.<strong>2.2</strong><br />
DOMESTIC DOORSETS APPROVED TO PAS 24-1<br />
Compatible Locking Options<br />
LPCB Ref. Trade Name Type Direction of<br />
No.<br />
Opening<br />
322c/02 Martin Roberts SD5001 Single leaf, hinged security<br />
doorsets<br />
Compatible Locking Systems<br />
Option<br />
Locking<br />
System<br />
Type<br />
External<br />
1 Assa 1520 Escape Sash Lock Key via an Assa 4801 single cylinder<br />
or<br />
Key via an Assa 4802 double cylinder<br />
Compatible Locking<br />
Systems<br />
Outward 2<br />
Inward 1<br />
Compatible External and Internal Operating Devices<br />
Internal<br />
Assa 6650C solid brass handle<br />
plus either<br />
Assa 6256 thumbturn or<br />
Key via an Assa 4802 double<br />
cylinder<br />
2 Assa 8761 Emergency Nightlatch Key via an Assa 4801 single cylinder Assa 640 solid brass handle<br />
Note<br />
1. The Martin Roberts SD5001 also meets the requirements of LPS 1175: Issue 5 and PAS 23-1: 1999. For further information, please<br />
refer to entries in <strong>section</strong>s on LPS 1175: Issue 5 and PAS 23-1 relating to LPCB certificates 322a and 322b respectively.<br />
Salisbury Glass Centre Limited<br />
Newton Road, Churchfields Industrial Estate, Salisbury, Wiltshire SP2 7QA, United Kingdom<br />
Tel: +44 (0)1722 342900 • Fax: +44 (0)1722 338784<br />
E-mail: commercialenquiries@salisbury-glass.com or domesticenquiries@salisbury-glass.com • Website:<br />
www.salisbury-glass.com<br />
Certificate No: 947a to PAS 23-1:1999 (incorporating amendments Nos. 1, 2, 3 and 4 and Corrigendum No. 1) and PAS 24:2007<br />
Hinged Doorsets<br />
Product<br />
Type<br />
Name<br />
Visoline<br />
Fully glazed single<br />
leaf outward opening<br />
aluminium doorset<br />
Minimum<br />
Structural<br />
Opening Height<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Width<br />
(m)<br />
Cert.<br />
No.<br />
1.85 <strong>2.2</strong> 0.8 1.05 947a/01<br />
Compatible Locking Systems<br />
Manufacturer Model Type<br />
Sobinco ACVL 415 Multipoint locking<br />
system<br />
Compatible Cylinders<br />
Operating Devices<br />
External Face Internal Face<br />
Key and Hoppe Key and Hoppe<br />
Tokyo PAS24 Tokyo PAS24<br />
lever handle set lever handle set<br />
Compatible<br />
Cylinders<br />
A<br />
Cylinder Reference Manufacturer Model Type<br />
A Securistyle Anti-manipulation Double europrofile cylinder (key/key)<br />
Note<br />
1. This doorset achieves exposure category '850 Special'.<br />
424 20 Nov 2011
PART 4: SECTION 5.3<br />
HIGH SECURITY WINDOWS<br />
The windows listed in this <strong>section</strong> are approved to LPS 1175 Requirements and testing procedures for the<br />
LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and<br />
free-standing barriers.<br />
The windows listed in this <strong>section</strong> are generally designed for use in commercial applications. Section 5.3.1<br />
lists external security windows while <strong>section</strong> 5.3.2 lists secondary glazing systems and <strong>section</strong> 5.3.3 lists<br />
rooflights.<br />
Windows approved to BS 7950 Specification for enhanced security performance of windows for domestic<br />
applications are listed in <strong>section</strong> 5.4.<br />
Unlike BS 7950, LPS 1175 can be applied to all designs and configurations of windows. Windows approved to<br />
LPS 1175 also generally offer much higher protection against forced entry than windows approved to BS<br />
7950. This is because windows approved to LPS 1175 are subjected to physical attack tests with a wide<br />
range of tools aimed at overcoming all aspects of the window including aspects omitted by BS 7950 such as<br />
the glazing and the fixings used to install the window.<br />
In addition to approving windows to LPS 1175 and BS 7950, LPCB also offer security performance approval<br />
of windows and other façade elements to EN 1627 as well as approvals covering other aspects of window<br />
performance, including weathertightness, thermal performance, fire and acoustics.<br />
LPCB has also published a standard for glazing and security glazing films which employs the principles<br />
contained within LPS 1175. LPS 1270 Requirements and testing procedures for the LPCB approval and listing<br />
of intruder resistant security glazing units covers the resistance to manual attack of the glazing material. It<br />
enables specifiers to select new or replacement glazing that affords two levels of security equivalent to that of<br />
the frame or façade in which it is to be employed.<br />
20 Nov 2011 425
PART 4: SECTION 5.3.1<br />
HIGH SECURITY WINDOWS - EXTERNAL WINDOWS<br />
Fendor Limited<br />
Heworth House, William Street, Felling, Gateshead NE10 0JP, United Kingdom<br />
Tel: +44 (0)191 438 3222 • Fax: +44 (0)191 438 1686<br />
E-mail: av@fendor.co.uk • Website: www.fendor.co.uk<br />
Certificate No: 712a to LPS 1175: Issue 5.1<br />
Security Windows<br />
Product Name Style Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
SecureLine<br />
SR2<br />
Top hung opening light<br />
SecureLine<br />
SR3<br />
SecureLine<br />
SR4<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Fixed light window 0.96 2.0 0.86 2.0 2 712a/01<br />
1.0 2.0 0.90 2.0 2<br />
window<br />
Fixed light window 0.96 2.0 0.86 2.0 3 712a/02<br />
Top hung opening light 1.0 2.0 0.90 2.0 3<br />
window<br />
Fixed light window 0.96 2.0 0.86 2.0 4 712a/03<br />
Cert.<br />
No.<br />
Compatible Locking Devices and Glazing<br />
LPCB<br />
Ref. No.<br />
712a/01<br />
Product<br />
Name<br />
SecureLine<br />
SR2<br />
Style<br />
Fixed light<br />
w indow<br />
Locking<br />
N/A<br />
Glazing 2<br />
Attack Face Non-attack Face<br />
8mm thick 32.8mm thick<br />
specialist laminated specialist laminated<br />
glazing unit double glazed unit<br />
Top hung<br />
opening light<br />
w indow<br />
Tw o Wilka dead locks<br />
w ith key operated<br />
cylinders<br />
8mm thick 32.8mm thick<br />
specialist laminated specialist laminated<br />
glazing unit double glazed unit<br />
712a/02<br />
SecureLine<br />
SR3<br />
Fixed light<br />
w indow<br />
N/A<br />
10mm thick 32.8mm thick<br />
specialist laminated specialist laminated<br />
glazing unit double glazed unit<br />
Top hung<br />
opening light<br />
w indow<br />
Tw o Wilka dead locks<br />
w ith key operated<br />
cylinders<br />
10mm thick 32.8mm thick<br />
specialist laminated specialist laminated<br />
glazing unit double glazed unit<br />
712a/03 SecureLine<br />
SR4<br />
Fixed light<br />
w indow<br />
N/A<br />
28mm thick<br />
specialist laninated<br />
glazing unit<br />
32.8mm thick<br />
specialist laminated<br />
double glazed unit<br />
Notes<br />
1. The SecureLine window systems should be mounted within the reveal, directly into the surrounding structure in accordance with<br />
installation instructions SL-02 (fixed light version) or SL-007 (top hung opening light version).<br />
2. Alternative glazing may not provide equivalent resistance to attack. Therefore, please consult Fendor Ltd before replacing or<br />
changing the glazing.<br />
426 20 Nov 2011
PART 4: SECTION 5.3.2<br />
HIGH SECURITY WINDOWS - SECONDARY GLAZING SYSTEMS<br />
Selectaglaze Limited<br />
Alban Park, Hatfield Road, St Albans, Hertfordshire AL4 0JJ, United Kingdom<br />
Tel: +44 (0)1727 837271 • Fax: +44 (0)1727 844053<br />
E-mail: enquiries@selectaglaze.co.uk • Website: www.selectaglaze.co.uk<br />
Certificate No: 683a to LPS 1175: Issue 6<br />
Secondary Security Glazing Systems<br />
Product Name Type Style Minimum<br />
Height<br />
(m)<br />
Series 50 'Level<br />
1'<br />
Series 50 'Level<br />
2'<br />
Series 55 'Level<br />
1'<br />
Series 55 'Level<br />
2'<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Single fixed light<br />
casement<br />
Single light inward<br />
opening<br />
top hung casement<br />
Single light inward<br />
opening<br />
side hung casement<br />
Single fixed light<br />
casement<br />
Single light inward<br />
opening<br />
top hung casement<br />
Single light inward<br />
opening<br />
side hung casement<br />
2H multiple fixed light<br />
demountable unit<br />
2V multiple fixed light<br />
demountable unit<br />
3H multiple fixed light<br />
demountable unit<br />
3V multiple fixed light<br />
demountable unit<br />
4H multiple fixed light<br />
demountable unit<br />
5H multiple fixed light<br />
demountable unit<br />
Single demountable<br />
fixed-light unit<br />
Single demountable<br />
fixed light unit<br />
2H multi-light<br />
demountable unit<br />
3H multi-light<br />
demountable unit<br />
4H multi-light<br />
demountable unit<br />
5H multi-light<br />
demountable unit<br />
Maximum<br />
Height<br />
(m) 1<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m) 1<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.4 3.2 3 0.4 3.2 3 1 683a/01<br />
0.43 1.5 3 0.574 3.2 3 1<br />
0.574 3.2 3 0.43 1.5 3 1<br />
0.4 3.2 3 0.4 3.2 3 2 683a/02<br />
0.43 1.5 3 0.574 3.2 3 2<br />
0.574 3.2 3 0.43 1.5 3 2<br />
0.4 3.2 3 0.8 4 3 1 683a/03<br />
0.8 4 3 0.4 3.2 3 1<br />
0.4 3.2 3 1.2 5 3 1<br />
1.2 5 3 0.4 3.2 3 1<br />
0.4 3.2 3 1.6 6 3 1<br />
0.4 3.2 3 2 6 3 1<br />
0.4 3.2 3 0.4 3.2 3 1<br />
0.4 3.2 3 0.4 3.2 3 2 683a/04<br />
0.4 3.2 3 0.8 4 3 2<br />
0.4 3.2 3 1.2 5 3 2<br />
0.4 3.2 3 1.6 6 3 2<br />
0.4 3.2 3 2 6 3 2<br />
20 Nov 2011 427
PART 4: SECTION 5.3.2<br />
HIGH SECURITY WINDOWS - SECONDARY GLAZING SYSTEMS<br />
Product Name Type Style Minimum<br />
Height<br />
(m)<br />
Series 55 'Level<br />
3'<br />
Series 85 'Level<br />
1'<br />
Series 85 'Level<br />
2'<br />
Series 95 'Level<br />
1'<br />
Series 95 'Level<br />
2'<br />
Series 42 'Level<br />
1'<br />
Series 42 'Level<br />
2'<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
Secondary<br />
glazing<br />
system<br />
2V multi-light<br />
demountable unit<br />
3V multi-light<br />
demountable unit<br />
Single demountable<br />
fixed light unit<br />
2H multi-light<br />
demountable unit<br />
3H multi-light<br />
demountable unit<br />
4H multi-light<br />
demountable unit<br />
5H multi-light<br />
demountable unit<br />
2V multi-light<br />
demountable unit<br />
3V multi-light<br />
demountable unit<br />
Twin light horizontally<br />
sliding casement<br />
Twin light horizontally<br />
sliding casement<br />
Twin light vertically<br />
sliding casement<br />
Twin light vertically<br />
sliding casement<br />
Maximum<br />
Height<br />
(m) 1<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m) 1<br />
Security<br />
Rating<br />
0.8 4 3 0.4 3.2 3 2<br />
1.2 5 3 0.4 3.2 3 2<br />
Cert.<br />
No.<br />
0.4 3.2 0.4 3.2 3 683a/06<br />
0.4 3.2 0.8 4 3<br />
0.4 3.2 1.2 5 3<br />
0.4 3.2 1.6 6 3<br />
0.4 3.2 2 6 3<br />
0.8 4 0.4 3.2 3<br />
1.2 5 0.4 3.2 3<br />
0.65 2.6 7 1 3 7 1 683a/05<br />
0.65 2.6 7 1 3 7 2 683a/07<br />
1 3 2, 7 0.65 2.6 2, 7 1 683a/08<br />
1 3 2, 7 0.65 2.6 2, 7 2 683a/09<br />
Single fixed light unit 0.3 3 7 0.3 2 7 1 683a/10<br />
Single fixed light unit 0.3 3 7 0.3 2 7 2 683a/11<br />
Compatible Locking and Glazing<br />
LPCB Trade Name Style Locking Systems Glazing 4<br />
Ref. No.<br />
683a/01 Series 50<br />
'Level 1'<br />
All single fixed light casements None 12.04 mm thick specialist laminated<br />
security glass<br />
All single light inw ard opening Selectaglaze proprietary 12.04 mm thick specialist laminated<br />
top hung and side hung<br />
casements<br />
espagnolette locking system w ith security glass<br />
Softline LM lockable handle<br />
683a/02 Series 50<br />
'Level 2'<br />
683a/03 Series 55<br />
'Level 1'<br />
683a/04 Series 55<br />
'Level 2'<br />
All single fixed light casements None 12 mm or 12.4 mm thick specialist<br />
laminated security glass<br />
All single light inw ard opening<br />
top hung and side hung<br />
casements<br />
All single and multiple light<br />
demountable units<br />
All single and multiple light<br />
demountable units<br />
Selectaglaze proprietary 12 mm or 12.4 mm thick specialist<br />
espagnolette locking system w ith laminated security glass<br />
Softline LM lockable handle<br />
None<br />
12.04 mm thick specialist laminated<br />
security glass<br />
None<br />
12 mm or 12.4 mm thick specialist<br />
laminated security glass<br />
428 20 Nov 2011
PART 4: SECTION 5.3.2<br />
HIGH SECURITY WINDOWS - SECONDARY GLAZING SYSTEMS<br />
683a/06 Series 55<br />
'Level 3'<br />
683a/05 Series 85<br />
'Level 1'<br />
683a/07 Series 85<br />
'Level 2'<br />
683a/08 Series 95<br />
'Level 1'<br />
683a/09 Series 95<br />
'Level 2'<br />
683a/10 Series 42<br />
'Level 1'<br />
683a/11 Series 42<br />
'Level 2'<br />
All single and multiple light<br />
demountable units<br />
Tw in light horizontally sliding<br />
casements<br />
Tw in light horizontally sliding<br />
casements<br />
Tw in light vertically sliding<br />
casements<br />
Tw in light vertically sliding<br />
casements<br />
None<br />
Selectaglaze proprietary<br />
espagnolette locking system<br />
Selectaglaze proprietary<br />
espagnolette locking system<br />
Selectaglaze proprietary<br />
espagnolette locking system<br />
Selectaglaze proprietary<br />
espagnolette locking system<br />
12 mm thick specialist laminated<br />
security glass<br />
12.04 mm thick specialist laminated<br />
security glass<br />
12 mm or 12.4 mm thick specialist<br />
laminated security glass<br />
12.04 mm thick specialist laminated<br />
security glass<br />
12 mm or 12.4 mm thick specialist<br />
laminated security glass<br />
Single fixed light units None 12.04 mm thick specialist laminated<br />
security glass<br />
Single fixed light units None 12 mm or 12.4 mm thick specialist<br />
laminated security glass<br />
Compatible Installation Configurations<br />
LPCB Ref.<br />
No.<br />
Trade Name Com patible Installation Configurations 5<br />
Masonry Structural Tim ber Timber Stud Structural Steel<br />
683a/01 Series 50 'Level 1' I and R 6 I and R 6 I and R 6 I and R 6<br />
683a/02 Series 50 'Level 2' I and R 6 I and R 6 - I and R 6<br />
683a/03 Series 55 'Level 1' I and R 6 I and R 6 I and R I and R 6<br />
683a/04 Series 55 'Level 2' I and R 6 I and R 6 - I and R 6<br />
683a/06 Series 55 'Level 3' I and R 6 I and R 6 - I and R 6<br />
683a/05 Series 85 'Level 1' I and R I and R I and R I and R<br />
683a/07 Series 85 'Level 2' I and R I and R - I and R<br />
683a/08 Series 95 'Level 1' I and R I and R I and R I and R<br />
683a/09 Series 95 'Level 2' I and R I and R - I and R<br />
683a/10 Series 42 'Level 1' I and R I and R I and R I and R<br />
683a/11 Series 42 'Level 2' I and R I and R - I and R<br />
Notes:<br />
1 The maximum size of casements and coupled systems are subject to specific assessment of physical restrictions and operational<br />
conditions.<br />
2 The maximum sash area available on Series 95 units is 3.5 m 2 .<br />
3 The Series 50 and Series 55 'Level 1' and 'Level 2' units can be joined together to form multi-light flat-coupled and bay systems using<br />
the Selectaglaze standard coupling, direct coupling and timber coupling methods, as appropriate. The security provided is equivalent<br />
to that offered by the lowest grade unit incorporated in the coupled system.<br />
4 Alternative glazing may not provide equivalent resistance to attack. Therefore, please consult Selectaglaze before replacing or<br />
changing the glazing.<br />
5 This assumes installation direct to substrate as detailed in document DS-003 (Issue AR, 07/049) and not via intermediate substrates,<br />
such as plasterboard. An 'I' indicates internal face fixed direct to structure while an 'R' indicates reveal mounted direct to structure.<br />
6 The Series 50 and Series 55 secondary glazing system may be mounted in the reveal (standard, tapered or splayed) or face fixed to<br />
the inside of the surrounding structure.<br />
7 The Series 42, 85 and 95 'Level 1' and 'Level 2' units can be joined together to form multi-light flat-coupled and bay systems using the<br />
Selectaglaze standard coupling and timber coupling methods, as appropriate. The security provided is equivalent to that offered by<br />
the lowest grade unit incorporated in the coupled system.<br />
20 Nov 2011 429
PART 4: SECTION 5.3.3<br />
ROOFLIGHTS<br />
The Rooflight Company<br />
Wychwood Business Centre, Milton Road, Shipton-under-Wychwood, Oxfordshire OX7 6XU, United Kingdom<br />
Tel: +44 (0)1993 833108 • Fax: +44 (0)1993 831066<br />
E-mail: info@therooflightcompany.co.uk • Website: www.therooflightcompany.co.uk<br />
Certificate No: 929a to LPS 1175: Issue 6<br />
Fixed Rooflights<br />
Product Name Type Minimum<br />
Length<br />
(m)<br />
Plateau Secured<br />
by Design: Level 2<br />
Plateau Secured<br />
by Design: Level 3<br />
Maximum<br />
Length<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Fixed rooflight 0.96 1.76 0.96 2.76 2 929a/01<br />
Fixed rooflight with<br />
integral security<br />
bars<br />
Cert.<br />
No.<br />
0.96 0.96 0.96 2.76 3 929a/02<br />
Note<br />
1 Approval is based upon installation of the rooflight onto a reinforced concrete kerb in accordance with drawing<br />
PS_100INST (Revision B dated 14 August 2009).<br />
430 20 Nov 2011
PART 4: SECTION 5.4<br />
DOMESTIC SECURITY WINDOWS<br />
Windows listed in this <strong>section</strong> are approved against the requirements of BS 7950 Specification for enhanced<br />
security performance of windows for domestic applications.<br />
The scope of windows covered by BS 7950 is restricted to the following:<br />
(i)<br />
(ii)<br />
(iii)<br />
(iv)<br />
(v)<br />
Casement windows - inward and outward opening side hung, outward opening top hung and inward<br />
opening bottom hung.<br />
Tilt/turn and turn/tilt windows.<br />
Fixed lights and dummy vents.<br />
Top swing.<br />
Vertical sliding.<br />
BS 7950 does not assess the resistance to entry by breaking glazing nor does it directly assess the fixing<br />
method employed.<br />
The concept of ‘enhanced security’ in this product standard is based upon a relationship between forced<br />
human intervention techniques with basic hand tools and resistance to entry under multi-directional loading<br />
and hard and soft body impact tests. The standard provides a means of evaluation of resistance to opportunist<br />
attack. The standard does not provide a means of evaluating the protection provided against unauthorised<br />
intrusion to the levels of attack or scope of entry methods covered within LPS 1175 Requirements and testing<br />
procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security<br />
enclosures and free-standing barriers.<br />
It is recommended that specifiers requiring windows outside the scope of BS 7950 or windows that exhibit<br />
resistance to methods of forced entry not covered by BS 7950, specify windows that have been approved to<br />
LPS 1175 (see products listed in <strong>section</strong> 5.3). Alternatively, specifiers should consider specifying additional<br />
window protection; such as grilles, shutters or secondary glazing systems; approved to LPS 1175.<br />
In addition to approving windows to LPS 1175 and BS 7950, LPCB also offer security performance approval<br />
of windows and other façade elements to EN 1627 as well as approvals covering other aspects of window<br />
performance, including weathertightness, thermal performance, fire and acoustics.<br />
LPCB has also published a standard for glazing and security glazing films which employs the principles<br />
contained within LPS 1175. LPS 1270 Requirements and testing procedures for the LPCB approval and listing<br />
of intruder resistant security glazing units covers the resistance to manual attack of the glazing material. It<br />
enables specifiers to select new or replacement glazing that affords two levels of security equivalent to that of<br />
the frame or façade in which it is to be employed.<br />
PRO TEC Vinduer A/S<br />
Nybovej 34, 7500 Holstebro, Denmark<br />
Tel: +45 9741 3077 • Fax: +45 9741 3060<br />
E-mail: protec@protecvinduer.com • Website: www.protecvinduer.com<br />
UK Sales<br />
PRO TEC Windows Limited, The Plough Barn, Feltmores Park, Chalk Lane, Moor Hall Road, Harlow CM17<br />
0PF, United Kingdom<br />
Tel: +44 (0)127 942 4004 • Fax: +44 (0)127 942 1709<br />
E-mail: protec@protecwindows.com • Website: www.protecwindows.com<br />
Certificate No: 930a to BS 7950: 1997, BS 6375-1: 2004 and BS 6375-2: 1987<br />
20 Nov 2011 431
PART 4: SECTION 5.4<br />
DOMESTIC SECURITY WINDOWS<br />
Windows<br />
Product<br />
Name<br />
PRO<br />
TEC<br />
Classic<br />
Type<br />
Aluminium/timber<br />
composite single fixed<br />
light windows<br />
Aluminium/timber<br />
composite single top<br />
hung casement<br />
windows<br />
Aluminium/timber<br />
composite single side<br />
hung casement<br />
windows<br />
Aluminium/timber<br />
composite single<br />
terrace side hung<br />
casement windows<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Compatible<br />
Locking<br />
System<br />
Cert.<br />
No.<br />
0.35 3 0.230 3 - 930a/01<br />
0.353 1.563 0.353 1.563 1 930a/02<br />
0.363 1.763 0.353 0.953 1 930a/03<br />
1.713 2.463 0.661 1.063 1 930a/04<br />
Approval Standards<br />
LPCB Ref.<br />
No.<br />
930a/01 PRO TEC<br />
Classic<br />
930a/02 PRO TEC<br />
Classic<br />
930a/03 PRO TEC<br />
Classic<br />
930a/04 PRO TEC<br />
Classic<br />
Trade Name Type BS 7950:<br />
1997<br />
Aluminium/timber composite<br />
single fixed light windows<br />
Aluminium/timber composite<br />
single top hung casement<br />
windows<br />
Aluminium/timber composite<br />
single side hung casement<br />
windows<br />
Aluminium/timber composite<br />
single terrace side hung<br />
casement windows<br />
BS 6375-1:<br />
2004<br />
BS 6375-2:<br />
1987<br />
UK<br />
Exposure<br />
Category<br />
1200<br />
Refer to<br />
note 1<br />
1200<br />
1200<br />
1200<br />
Compatible Locking System<br />
Compatible Locking Manufacturer Model Type<br />
System<br />
1 Mila A/S Garant D28 Multipoint locking system incorporating four<br />
locking points and key lockable handle<br />
Note<br />
1. Fixed light windows are outside the scope of BS 6375-2: 1987.<br />
Salisbury Glass Centre Limited<br />
Newton Road, Churchfields Industrial Estate, Salisbury, Wiltshire SP2 7QA, United Kingdom<br />
Tel: +44 (0)1722 342900 • Fax: +44 (0)1722 338784<br />
E-mail: commercialenquiries@salisbury-glass.com or domesticenquiries@salisbury-glass.com • Website:<br />
www.salisbury-glass.com<br />
Certificate No: 947b to BS 7950: 1997, BS 6375-1: 2004, BS 6375-2: 1987 and BS 4873: 2004<br />
432 20 Nov 2011
PART 4: SECTION 5.4<br />
DOMESTIC SECURITY WINDOWS<br />
Domestic Window<br />
Product Type<br />
Name<br />
Visoline<br />
Internally glazed<br />
inward opening<br />
tilt/turn<br />
aluminium<br />
window<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Compatible<br />
Locking<br />
Systems<br />
Cert.<br />
No.<br />
0.8 2 0.7 1.2 1 947b/01<br />
Approval Standards<br />
LPCB Ref.<br />
No.<br />
Trade Name Type BS 7950:1997 BS 6375-1:2004<br />
(UK Exposure<br />
Category)<br />
947b/01 Visoline Internally glazed inw ard opening<br />
tilt/turn aluminium w indow<br />
Compatible Locking Systems<br />
BS 6375-2:1987 BS 4873:2004<br />
2000+ <br />
Compatible Manufacturer Model Type<br />
Locking System<br />
1 Fappin ACFA 061 Multi point tilt/turn locking system with additional ACFA 078 locking points and ACFA 082<br />
key locking handle on the internal face.<br />
Note:<br />
1. This approval only covers single light units.<br />
Certificate No: 947c to BS 7950: 1997, BS 6375-1: 2009, BS 6375-2: 2009 and BS 4873: 2009<br />
Domestic Window<br />
Product Type<br />
Name<br />
Technal<br />
FXi52<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Compatible<br />
Locking<br />
System<br />
Inward opening<br />
tilt/turn<br />
aluminium<br />
window 1 0.6 2.38 0.6 1.26 1 947c/01<br />
Cert.<br />
No.<br />
Compatible Locking System<br />
Compatible<br />
Locking<br />
System<br />
Manufacturer Model Type Operating Devices<br />
External Face<br />
Internal Face<br />
1 Seigenia SI-line TBT 90 Key locking handle None Key locking<br />
Seigenia SI-line LM 4200 TBT-E-WK2 Tilt/turn locking system<br />
handle<br />
Exposure Category<br />
Cert. No. Trade Name Type UK Exposure Category<br />
947c/01 Technal FXi52 Inw ard opening tilt/turn aluminium w indow 2000+<br />
Note:<br />
1. This approval covers single light units.<br />
20 Nov 2011 433
PART 4: SECTION 5.5<br />
SECURITY GRILLES, BLINDS AND BARSETS<br />
Security grilles, blinds and barsets listed in this <strong>section</strong> are approved to LPS 1175 Requirements and testing<br />
procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security<br />
enclosures and free-standing barriers.<br />
Bradbury Security<br />
Dunlop Way, Queensway Industrial Estate, Scunthorpe DN16 3RN, United Kingdom<br />
Tel: +44 (0)1724 271999 • Fax: +44 (0)1724 271888<br />
E-mail: sales@bradburyuk.com • Website: www.bradburyuk.com<br />
Certificate No: 312a to LPS 1175: Issue 5<br />
Security Grilles<br />
Product<br />
Name<br />
CX2<br />
Type<br />
Single gate collapsible<br />
security grille<br />
Double gate collapsible<br />
security grille<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.7 3.0 0.4 3.0 1 312a/04<br />
0.7 3.0 0.4 6.0 1<br />
Compatible Locking Devices<br />
LPCB Ref.<br />
No.<br />
Bradbury CX250<br />
two point slam<br />
lock<br />
Lock<br />
Bradbury CX500<br />
two point slam<br />
lock<br />
Bradbury CX1000<br />
two point slam<br />
lock<br />
Cylinders<br />
312a/04 CX2 single or double<br />
Europrofile cylinder<br />
Approved Accessories<br />
None.<br />
Approved Installation Configurations 1<br />
Configuration<br />
Substrate<br />
Brick Concrete Structural<br />
Steel<br />
Structural<br />
Timber<br />
Reveal <br />
Internal face fixed <br />
Note<br />
1. This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.<br />
Henry Lewis and Sons (Wireworkers) Limited<br />
Unit 7, Bolling Road Industrial Estate, Bradford BD4 7HN, United Kingdom<br />
Tel: +44 (0) 1274 307359 • Fax: +44 (0) 1274 370784<br />
E-mail: info@henrylewisandson.co.uk • Website: www.henrylewisandson.co.uk<br />
Certificate No: 528a to LPS 1175: Issue 5<br />
Security Grilles<br />
Product<br />
Name<br />
Balmoral<br />
Type<br />
Single gate<br />
collapsible grille<br />
Minimum<br />
Width<br />
(mm)<br />
Maximum<br />
Width<br />
(mm)<br />
Minimum<br />
Height<br />
(mm)<br />
Maximum<br />
Height<br />
(mm)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
500 6000 650 3046 1 528a/01<br />
434 20 Nov 2011
PART 4: SECTION 5.5<br />
SECURITY GRILLES, BLINDS AND BARSETS<br />
Product<br />
Name<br />
Type<br />
Minimum<br />
Width<br />
(mm)<br />
Maximum<br />
Width<br />
(mm)<br />
Minimum<br />
Height<br />
(mm)<br />
Maximum<br />
Height<br />
(mm)<br />
Security<br />
Rating<br />
Double gate<br />
500 6000 650 3046 1 528a/02<br />
collapsible grille<br />
Fixed grille 500 6000 650 3046 1 528a/03<br />
Cert.<br />
No.<br />
Compatible Locking Devices<br />
Lock Cylinder Approved Product (LPCB Ref. No. 528a/…)<br />
Adams Rite<br />
MS1900<br />
Approved Accessories<br />
1 2 3<br />
ASEC AS 1193 single europrofile <br />
ASEC AS 1153 double europrofile <br />
Accessory<br />
Approved Product (LPCB Ref. No. 528a/…)<br />
1 2 3<br />
Removable bottom track <br />
Lift up (hinged) bottom<br />
track<br />
<br />
<br />
Approved Installation Configurations 1<br />
Configuration<br />
Compatible Substrates<br />
Brick Concrete Structural<br />
Steel<br />
Structural<br />
Timber<br />
Reveal <br />
Internal face<br />
<br />
External face<br />
<br />
Note<br />
1. This assumes installation direct to substrate and not via intermediate substrates such as plasterboard.<br />
Liddle Doors Limited<br />
Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom<br />
Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698<br />
E-mail: liddle@liddledoors.co.uk • Website: www.liddledoors.co.uk<br />
Certificate No: 442d to LPS 1175: Issue 6<br />
Fixed Security Bar Sets<br />
Product Type<br />
Name<br />
Liddle<br />
Series 2<br />
security bar<br />
set<br />
Liddle<br />
Series 3<br />
security bar<br />
set<br />
Reveal mounted<br />
security bar set<br />
Internally or<br />
externally face<br />
fixed security<br />
bar set<br />
Reveal mounted<br />
security bar set<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.4 2.7 0.4 3.0 2 442d/01<br />
0.1 <strong>2.2</strong>4 0.1 2.54 2<br />
0.4 2.7 0.4 3.0 3 442d/02<br />
20 Nov 2011 435
PART 4: SECTION 5.5<br />
SECURITY GRILLES, BLINDS AND BARSETS<br />
Product<br />
Name<br />
Type<br />
Internally or<br />
externally face<br />
fixed security<br />
bar set<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening Width<br />
(m)<br />
Security<br />
Rating<br />
0.1 <strong>2.2</strong>4 0.1 2.54 3<br />
Cert.<br />
No.<br />
Note<br />
1. The bar sets are approved when installed directly to brickwork, concrete or steel. The approval does not cover the bar sets when<br />
mounted to alternative substrates or via intermediate substrates such as plasterboard.<br />
Lowrey Contractors Limited<br />
200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom<br />
Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111<br />
E-mail: lowrey@talk21.com • Website: www.lowrey-contractors.co.uk<br />
Certificate No: 974g to LPS 1175: Issue 7<br />
Fixed Security Barsets<br />
Product<br />
Name<br />
Product<br />
Type<br />
Installation<br />
Anti- Individual Reveal<br />
Intruder security mounted<br />
barset<br />
Individual<br />
security<br />
barset<br />
Individual<br />
security<br />
barset<br />
Modular<br />
security<br />
barset<br />
Modular<br />
security<br />
barset<br />
Modular<br />
security<br />
barset<br />
External face<br />
fixed<br />
Internal face<br />
fixed<br />
Reveal<br />
mounted<br />
External face<br />
fixed<br />
Internal face<br />
fixed<br />
Minimum<br />
Height (m)<br />
Maximum<br />
Height (m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.55 2.1 0.55 2.1 3 974g/01<br />
0.45 2.0 0.45 2.0 3<br />
0.45 2.0 0.45 2.0 3<br />
0.55 Unlimited 1 0.55 Unlimited 1 3<br />
0.45 Unlimited 1 0.45 Unlimited 1 3<br />
0.45 Unlimited 1 0.45 Unlimited 1 3<br />
Notes:<br />
1. The maximum minor dimension approved is 4.1 m. This is because the number of individual barsets that can be connected is<br />
restricted to a maximum of two in the minor dimension. However, the barset’s size is unrestricted in the major direction.<br />
2. The barsets are approved when installed in accordance with the instructions detailed on document SB/3BS/INS (Issue 4).<br />
Professional Barrier Systems Limited<br />
16 Stapledon Road, Orton Southgate, Peterborough PE2 6TD, United Kingdom<br />
Tel: +44 (0)1733 361511 • Fax: +44 (0)1733 361512<br />
E-mail: mail@extendor.co.uk • Website: www.extendor.co.uk<br />
Certificate No: 869a to LPS 1175: Issue 6<br />
Security Grilles<br />
Product<br />
Name<br />
Extendor<br />
Eclipse<br />
Type<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Fixed security grille 0.5 3.58 0.3 5.75 3 869a/01<br />
Cert.<br />
No.<br />
436 20 Nov 2011
PART 4: SECTION 5.5<br />
SECURITY GRILLES, BLINDS AND BARSETS<br />
Product<br />
Name<br />
Type<br />
Single sash collapsible<br />
security grille<br />
Double sash collapsible<br />
security grille<br />
Flexi single and multiple<br />
sash collapsible security<br />
grille<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
0.625 2.7 0.39 5.75 3<br />
0.625 2.7 0.44 11.5 1 3<br />
0.625 2.7 0.44 Unlimited 1 3<br />
Cert.<br />
No.<br />
Compatible Locking Devices<br />
Product Name Type Lock Compatible<br />
Cylinders<br />
Extendor Eclipse Single sash collapsible security grille Extendor Eclipse CL03 lock<br />
with CL03 cylinder guard 2<br />
Compatible Cylinders<br />
Double sash collapsible security<br />
grille<br />
‘Flexi’ single and multiple sash<br />
collapsible security grille<br />
Compatible Cylinders Cylinders<br />
1 Assa dp4400 single europrofile<br />
2 CISA AP3S single europrofile<br />
3 Kaba Quattro Plus single europrofile<br />
Approved Accessories<br />
Recessed track and deep rail cover channel.<br />
Approved Installation Configurations 3<br />
Extendor Eclipse CL03 lock<br />
1 to 3<br />
with CL03 cylinder guard 2<br />
Extendor Eclipse CL03 lock<br />
1 to 3<br />
with CL03 cylinder guard 2<br />
Configuration<br />
Substrate<br />
Brickwork Concrete<br />
Blockwork<br />
Concrete Structural<br />
Timber<br />
Reveal <br />
Internal Face <br />
Notes<br />
1. The maximum width of any sash is 5.75 m.<br />
2. The CL03 cylinder guard is only required for protecting cylinders on the attack side of the grille.<br />
3. Installation into other substrates should be assessed by LPCB to ensure the installation method offers compatible resistance to<br />
attack.<br />
Safeguard Security, a trade name of WBH Industries<br />
Unit 5, 229 Torrington Avenue, Coventry CV4 9HN, United Kingdom<br />
Tel: +44 (0)2476 470 600 • Fax: +44 (0)2476 471 600<br />
E-mail: info@safeguardsecurity.co.uk • Website: www.safeguardsecurity.co.uk<br />
Certificate No: 418a to LPS 1175: Issue 5<br />
Security Grilles<br />
Product<br />
Name<br />
LPC1 System<br />
Type<br />
Single gate, collapsible security<br />
grille<br />
Double gate, collapsible<br />
security grille<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.594 3.0 0.233 6.0 1 418a/01<br />
0.594 3.0 0.405 12.0 1<br />
20 Nov 2011 437
PART 4: SECTION 5.5<br />
SECURITY GRILLES, BLINDS AND BARSETS<br />
Compatible Locking Devices<br />
LPCB Ref. Product Name Type Locks Cylinder<br />
No.<br />
418a/01 LPC1 System Single and double gate<br />
collapsible security grille<br />
Adams Rite MS 1900 hook<br />
lock<br />
Sofi 5-pin single Europrofile<br />
Approved Installations Configurations 1<br />
Configuration<br />
Substrate<br />
Brick Concrete Blockwork Timber Steel<br />
Reveal <br />
Internal face fixed <br />
Note:<br />
1. This assumes installation direct to the substrate and not via intermediate substrates, such as plasterboard.<br />
Security Blinds Limited<br />
Units 3 A/B, Hope Street, Thornhill Industrial Estate, Rotherham S60 1LH, United Kingdom<br />
Tel: +44 (0)1709 363535 • Fax: +44 (0)1709 364512<br />
E-mail: info@securityblinds.co.uk • Website: www.securityblinds.co.uk<br />
Certificate No: 854a to LPS 1175: Issue 5<br />
Security Blinds<br />
Product Name Model Type Minimum<br />
Height<br />
(m)<br />
Secur 950031 Single leaf inward<br />
opening vertical<br />
blind unit<br />
950032 Single leaf inward<br />
opening vertical<br />
blind unit with<br />
transom<br />
950033 Double leaf<br />
horizontal sliding<br />
verticial blind unit<br />
950034 Double leaf<br />
horizontal sliding<br />
vertical blind unit<br />
with transom<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
SecurityRating<br />
Cert. No.<br />
0.5 0.324 2.5 1.399 2 854a/01<br />
0.5 0.324 2.5 1.3999 2<br />
0.5 0.918 2.5 3.018 2<br />
0.5 0.918 2.5 3.018 2<br />
Compatible Locking Devices<br />
LPCB Ref. Model Lock Cylinder<br />
No.<br />
854a/01 950031 CISA 46270-25 tw o w ay locking system C2000 European single europrofile cylinder<br />
950032<br />
950033<br />
950034<br />
Approved Installation Configurations 1<br />
Configuration<br />
Substrate<br />
Brick Concrete Blockw ork<br />
Reveal <br />
Note:<br />
1. This assumes installation direct to the substrate and not via intermediate substrates, such as plasterboard.<br />
438 20 Nov 2011
PART 4: SECTION 5.5<br />
SECURITY GRILLES, BLINDS AND BARSETS<br />
Simbars (UK) Limited<br />
Unit 2, 46 Ashton Vale Road, Ashton, Bristol BS3 2HQ, United Kingdom<br />
Tel: +44 (0)117 953 1444 • Fax: +44 (0)117 963 1444<br />
E-mail: info@simbars.co.uk • Website: www.simbars.co.uk<br />
Certificate No: 932a to LPS 1175: Issue 6<br />
Fixed Security Bar Sets<br />
Product Name Type Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Simbars<br />
security bar sets<br />
SR3<br />
Simbars<br />
security bar sets<br />
SR4<br />
Reveal mounted<br />
security bar set<br />
Internally face<br />
fixed security bar<br />
set<br />
Reveal mounted<br />
security bar set<br />
Internally face<br />
fixed security bar<br />
set<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.6 8.0 0.6 6.0 3 932a/01<br />
0.14 7.54 0.14 5.54 3<br />
0.225 8.0 0.225 6.0 4 932a/02<br />
0.227 7.54 0.29 5.54 4<br />
Note<br />
1. The bar sets are approved when installed directly to structural concrete using the fixings specified on drawings A1-00056 Revision<br />
F and A1-00104 Revision B (Internal face fixed) and A1-00057 Revision E and A1-00108 Revision C (Reveal mounted). The<br />
approval does not cover the bar sets when mounted to alternative substrates or via intermediate substrates such as plasterboard.<br />
SWS UK<br />
Hornby Road, Claughton, Lancaster LA2 9LA, United Kingdom<br />
Tel: +44 (0)1524 772400 • Fax: +44 (0)1524 772411<br />
E-mail: info@swsuk.co.uk • Website: www.swsuk.co.uk<br />
Certificate No: 390a to LPS 1175: Issue 5<br />
Security Grilles<br />
Product Name Type Minimum<br />
Height<br />
(m)<br />
SeceuroGuard 1001 Single gate<br />
collapsible security<br />
grille<br />
SeceuroGuard 1001<br />
"Fixed"<br />
SeceuroGuard 1001<br />
"Floating"<br />
SeceuroGuard 1001<br />
SeceuroGuard 1001s<br />
SeceuroGuard 1001s<br />
"Fixed"<br />
SeceuroGuard 1001s<br />
"Floating"<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1 0.5 3 3 1 390a/01<br />
Fixed security grille 1 0.5 3 3 1<br />
Single gate<br />
collapsible security<br />
grille<br />
1 0.5 3 3 1<br />
Double gate<br />
1 1 3 6.5 1<br />
collapsible security<br />
grille<br />
Single gate<br />
1 0.5 3 3 1 390a/03<br />
collapsible security<br />
grille<br />
Fixed security grille 1 0.5 3 3 1<br />
Single gate<br />
collapsible security<br />
grille<br />
1 0.5 3 3 1<br />
20 Nov 2011 439
PART 4: SECTION 5.5<br />
SECURITY GRILLES, BLINDS AND BARSETS<br />
Product Name Type Minimum<br />
Height<br />
(m)<br />
SeceuroGuard 1001s Double gate<br />
collapsible security<br />
grille<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
1 1 3 6.5 1<br />
Cert.<br />
No.<br />
Compatible Locking Devices<br />
LPCB Ref. Trade Name Type Locks<br />
No.<br />
390a/01 SeceuroGuard 1001 Single gate collapsible<br />
security grille<br />
Viro 8300 extensible gate<br />
lock with 5-pin cylinder<br />
SeceuroGuard 1001 Fixed security grille N/A<br />
“Fixed”<br />
SeceuroGuard 1001<br />
“Floating”<br />
Single gate collapsible<br />
security grille<br />
Viro 8300 extensible gate<br />
lock with 5-pin cylinder<br />
SeceuroGuard 1001 Double gate collapsible<br />
security grille<br />
Viro 8300 extensible gate<br />
lock with 5-pin cylinder<br />
390a/03 S-lattice SeceuroGuard<br />
1001s<br />
Single gate collapsible<br />
security grille<br />
Viro 8300 extensible gate<br />
lock with 5-pin cylinder<br />
S-lattice SeceuroGuard Fixed security grille N/A<br />
1001s “Fixed”<br />
S-lattice SeceuroGuard<br />
1001s “Floating”<br />
Single gate collapsible<br />
security grille<br />
Viro 8300 extensible gate<br />
lock with 5-pin cylinder<br />
S-lattice SeceuroGuard<br />
1001s<br />
Double gate collapsible<br />
security grille<br />
Viro 8300 extensible gate<br />
lock with 5-pin cylinder<br />
Approved Accessories<br />
Accessory<br />
Associated Products (LPCB Ref. No. 390a/...)<br />
1 3<br />
Folding bottom track 1 <br />
Approved Installation Configurations 2<br />
Configuration<br />
Substrate<br />
Brick Concrete Structural<br />
Steel<br />
Structural<br />
Timber<br />
Reveal <br />
Internal face fixed 2 <br />
Notes<br />
1. The folding bottom track is approved as an option on the single gate and double gate SeceuroGuard 1001 and SeceuroGuard<br />
1001s models only.<br />
2. This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.<br />
The Expanded Metal Company Limited<br />
P.O.Box 14, Longhill Industrial Estate (North), Hartlepool TS25 1PR, United Kingdom<br />
Tel: +44 (0)1429 867 388 • Fax: +44 (0)1429 867 355<br />
E-mail: fencing@expamet.co.uk • Website: www.expandedmetalfencing.co.uk<br />
Certificate No: 731d to LPS 1175: Issue 6<br />
440 20 Nov 2011
Fixed Security Window Guard<br />
Product<br />
Name<br />
Type<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Class 3<br />
Window<br />
Guard<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
PART 4: SECTION 5.5<br />
SECURITY GRILLES, BLINDS AND BARSETS<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Security<br />
Rating<br />
Rectangular<br />
0.5 4.0 0.5 2.0 3 731d/01<br />
vertical bars 1<br />
security window<br />
guards with square<br />
Rectangular<br />
security window<br />
guards with round<br />
vertical bars 2 0.5 4.0 0.5 2.0 3 731d/02<br />
Cert.<br />
No.<br />
Notes<br />
1. The window guards are approved when reveal mounted directly into solid brickwork or concrete structures of equivalent resistance<br />
to attack in accordance with the installation instructions contained in documents C3WG/RHS/P1 (Issue B), C3WG/RHS/P2 (Issue<br />
A), C3WG/RHS/P3 (Issue A) and C3WG/RHS/P4 (Issue A).<br />
2. The window guards are approved when reveal mounted directly into solid brickwork or concrete structures of equivalent resistance<br />
to attack in accordance with the installation instructions contained in drawings C3WG/BAR/P1 (Issue B), C3WG/BAR/P2 (Issue A),<br />
C3WG/BAR/P3 (Issue A) and C3WG/BAR/P4 (Issue A).<br />
3. The approval does not cover the window guards when mounted to alternative substrates or via intermediate substrates such as<br />
plasterboard.<br />
Trellicor (Pty) Limited<br />
20 Aberdare Drive, Phoenix Industrial Park, Durban, South Africa<br />
Tel: +27 31 500 4301 • Fax: +27 31 507 2129/3973<br />
Certificate No: 474a to LPS 1175: Issue 5<br />
Security Grilles<br />
Product<br />
Name<br />
Model Type Minimum<br />
Height<br />
(m)<br />
Trellidor<br />
Trojan II<br />
Trellidor<br />
Trojan II<br />
EMESC<br />
Standard<br />
Flexi<br />
Fixture<br />
Double<br />
Double<br />
flexi<br />
Standard<br />
Flexi<br />
Double<br />
Double<br />
flexi<br />
Single gate<br />
collapsible<br />
security grille<br />
Single gate<br />
collapsible<br />
security grille<br />
Single gate<br />
collapsible<br />
security grille<br />
Single gate<br />
collapsible<br />
security grille<br />
Double gate<br />
collapsible<br />
security grille<br />
Double gate<br />
collapsible<br />
security grille<br />
Single gate<br />
collapsible<br />
security grille<br />
Single gate<br />
collapsible<br />
security grille<br />
Double gate<br />
collapsible<br />
security grille<br />
Double gate<br />
collapsible<br />
security grille<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1.195 1.0 3.0 5.0 2 474a/04<br />
1.195 1.0 3.0 5.0 2<br />
1.195 1.0 3.0 5.0 2<br />
1.195 2.0 3.0 10.0 2<br />
1.195 2.0 3.0 10.0 2<br />
1.780 1.0 3.0 5.0 2 474a/05<br />
1-780 1.0 3.0 5.0 2<br />
1.780 2.0 3.0 10.0 2<br />
1.780 2.0 3.0 10.0 2<br />
Compatible Locking Devices<br />
20 Nov 2011 441
PART 4: SECTION 5.5<br />
SECURITY GRILLES, BLINDS AND BARSETS<br />
LPCB Ref.<br />
No.<br />
Trade<br />
Name<br />
474a/04 Trellidor<br />
Trojan II<br />
474a/05 Trellidor<br />
Trojan II<br />
EMESC<br />
Model<br />
Lock<br />
Trellidor<br />
single<br />
europrofile<br />
Cylinder<br />
Trellidor<br />
double<br />
europrofile<br />
Trellidor double<br />
europrofile<br />
(key:key) (key:thumbturn) 1<br />
Standard Trellilok (Mark IV) -<br />
Flexi Trellilok (Mark IV) -<br />
Fixture N/A - - -<br />
Double Trellilok (Mark IV) -<br />
Double Trellilok (Mark IV)<br />
-<br />
flexi<br />
<br />
<br />
Standard Trellilok (Mark IV) - - <br />
Flexi Trellilok (Mark IV) - - <br />
Double Trellilok (Mark IV) - - <br />
Double<br />
flexi<br />
Trellilok (Mark IV)<br />
- - <br />
LPCB Ref.<br />
No.<br />
Brick Concrete<br />
Blockwork<br />
Product Name Configuration Substrate<br />
Stone<br />
Structural<br />
Steel<br />
Structural<br />
Timber<br />
474a/04 Trellidor Trojan II Reveal <br />
474a/05 Trellidor Trojan II<br />
EMESC<br />
Notes<br />
Reveal <br />
1. Thumbturn is located on non-attack side of the grille with a protection shroud.<br />
2. This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.<br />
Certificate No: 474b to LPS 1175: Issue 6<br />
Security grilles<br />
Product Name Model Type Minimum<br />
Height<br />
(m)<br />
Trellidor Plus Standard Single gate<br />
collapsible security<br />
grille<br />
Flexi Single gate<br />
collapsible security<br />
grille<br />
Fixture Single gate<br />
collapsible security<br />
grille<br />
Double Double gate<br />
collapsible security<br />
grille<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert. No.<br />
0.945 0.6 3.0 5.0 1 474b/01<br />
0.945 1.0 3.0 5.0 1<br />
0.945 0.6 3.0 5.0 1<br />
0.945 1.0 3.0 10.0 1<br />
Compatible Locking Devices<br />
LPCB Ref. No.<br />
474b/01<br />
Model<br />
Lock<br />
Cylinder<br />
Trellidor single Trellidor double europrofile<br />
europrofile<br />
Standard Trellilok (Mark IV) <br />
Flexi Trellilok (Mark IV) <br />
Fixture N/A N/A N/A<br />
Double Trellilok (Mark IV) <br />
442 20 Nov 2011
PART 4: SECTION 5.5<br />
SECURITY GRILLES, BLINDS AND BARSETS<br />
Approved Accessories<br />
Accessory<br />
Hinged bottom track<br />
Removable bottom track<br />
Approved Product (LPCB Ref. No. 474b/...)<br />
01<br />
<br />
<br />
Approved Instllation Configurations 1<br />
Configuration<br />
Substrate<br />
Brick Concrete Structural Steel Structural Timber<br />
Reveal <br />
Note<br />
1. This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.<br />
20 Nov 2011 443
PART 4: SECTION 5.6<br />
SECURITY SHUTTERS<br />
Security shutters listed in this <strong>section</strong> are approved to LPS 1175 Requirements and testing procedures for the<br />
LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and<br />
free-standing barriers.<br />
In addition to approving shutters to LPS 1175, LPCB also offer security performance approval of shutters to<br />
EN1627 aswell as approvals covering other aspects of shutter performance including weathertightness,<br />
thermal performance, fire and acoustics.<br />
Aluroll Limited<br />
Mile Oak Industrial Estate, Maesbury Road, Oswestry, Shropshire SY10 8GA, United Kingdom<br />
Tel: +44 (0)800 977 8975 • Fax: +44 (0)1691 671 482<br />
E-mail: enquiry@aluroll.co.uk • Website: www.aluroll.co.uk<br />
Certificate No: 931a to LPS 1175: Issue 6<br />
Security Shutters<br />
Product Type<br />
Name<br />
E37<br />
Elite<br />
T77<br />
Elite (1)<br />
V77<br />
Elite<br />
E77<br />
Elite<br />
Externally<br />
face fitted<br />
double skin<br />
aluminium<br />
roller shutter<br />
Internally<br />
face fitted<br />
double skin<br />
insulated<br />
roller shutter<br />
Internally<br />
face fitted<br />
aluminium<br />
roller shutter<br />
with vision<br />
slats<br />
Internally<br />
face fitted<br />
aluminium<br />
roller shutter<br />
Minimum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum Compatible<br />
Door Locking<br />
Area Devices<br />
(m 2<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.9 4.0 0.77 3.0 8.5 A 1 931a/01<br />
0.9 2 5.2 0.9 5.0 20 B 1 931a/02<br />
0.9 2 5.2 0.9 5.0 25 B 2 931a/03<br />
0.9 2 5.2 0.9 5.0 25 B 2 931a/04<br />
Compatible Locking Devices<br />
Compatible<br />
Locking<br />
Device<br />
External<br />
Internal<br />
A Tw o Hopkins bullet H75 locks plus w ireless keypad and/or keyfob Push button motor control 4<br />
motor control 3 and external manual override handle protected by<br />
Alukon 380370100 locking cap<br />
B Wireless keypad and/or keyfob motor control 3 Push button motor control 4 w ith<br />
internal manual override handle 5<br />
Compatible Substrates<br />
Locking / Operating Devices<br />
444 20 Nov 2011
Trade Name Type<br />
PART 4: SECTION 5.6<br />
SECURITY SHUTTERS<br />
Compatible Substrates<br />
Masonry Steelw ork Aluminium<br />
E37 Elite Externally face fitted double skin aluminium roller shutter <br />
T77 Elite Internally face fitted double skin insulated roller shutter 2<br />
V77 Elite Internally face fitted aluminium roller shutter w ith vision slats 2<br />
E77 Elite Internally face fitted aluminium roller shutter 2<br />
Notes:<br />
1. The T77 Elite is also marketed as an Elite garage door. That is available over the same size range and with same locking devices.<br />
2. The T77 Elite, V77 Elite and E77 Elite roller shutters must have a minimum structural opening height of 2 m when installed on<br />
aluminium substrates.<br />
3. The resistance of the wireless keypad and keyfob motor control to “non-mechanical” attack is not covered by this approval as they are<br />
outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the<br />
functionality and performance of the wireless keypad and keyfob motor control equipment. It is therefore recommended that<br />
specifiers’ satisfy themselves that the components used are either resistant other forms of tampering/abuse, or that they are suitably<br />
protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking<br />
system to disengage.<br />
4. The push button controller should be located on the protected side of the shutter at least 1.5 m from the shutter curtain.<br />
5. The manual override handle should be stored on the protected side of the shutter at least 1.5 m from the shutter curtain.<br />
Ascot Doors Limited<br />
Britannia Way Industrial Park, Union Road, Bolton BL2 2HE, United Kingdom<br />
Tel: +44 (0)1204 545801 • Fax: +44 (0)1204 545800<br />
E-mail: sales@ascotdoors.co.uk • Website: www.ascotdoors.co.uk<br />
Certificate No: 131b to LPS 1175: Issue 3<br />
Security Shutters<br />
Product Type<br />
Name<br />
A320<br />
Rolling<br />
shutter<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
2 7 2.5 9 4 131b/01<br />
Compatible Locking Devices<br />
LPCB Ref. Product Type<br />
Lock<br />
No. Name<br />
131b/01 A320 Rolling Shutter H75H Euro Guide Bullet Pin Lock<br />
Note<br />
1. A centre ground lock must be provided on shutters of greater than 5 metres width.<br />
Certificate No: 131e to LPS 1175: Issue 6<br />
Security Shutters<br />
Product Name Model Type Security Rating Cert. No.<br />
Centurion A305SS Roller shutter with solid single skin steel lath 1 131e/01<br />
A305PS Roller shutter with perforated single skin steel lath 1 131e/02<br />
A305SA Roller shutter with solid single skin aluminium lath 1 131e/03<br />
A305PA Roller shutter with punched aluminium lath 1 131e/04<br />
A305PG Roller shutter with punched and glazed aluminium lath 1 131e/05<br />
A310SS Roller shutter with solid single skin steel lath 2 131e/06<br />
A315 Roller shutter with reinforced double skin aluminium lath 3 131e/07<br />
Configurations, Sizes and Locking<br />
20 Nov 2011 445
PART 4: SECTION 5.6<br />
SECURITY SHUTTERS<br />
Models Orientation Operation Minimum<br />
Height<br />
(m)<br />
A305SS<br />
A305PS<br />
A305SA<br />
A305PA<br />
A305PG<br />
A310SS<br />
A315<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Locking<br />
Reveal Push up 1 3 1 3 Hopkins H75 pin lock fitted to internal<br />
or external face<br />
Tube motor 1 7 1 7 Hopkins H75 pin lock fitted to internal<br />
or external face<br />
Internal Push up 1 3 1 3 Hopkins H75 pin lock fitted to internal<br />
face<br />
Tube motor 1 7 1 7 Hopkins H75 pin lock fitted to internal<br />
face<br />
Direct drive 1 7 1 7 Hopkins H75 pin lock fitted to internal<br />
face<br />
Reveal Push up 1 3 1 3 Hopkins H75 pin lock fitted to internal<br />
or external face<br />
Tube motor 1 7 1 7 Hopkins H75 pin lock fitted to internal<br />
or external face<br />
Internal Push up 1 3 1 3 Hopkins H75 pin lock fitted to internal<br />
face<br />
Tube motor 1 7 1 7 Hopkins H75 pin lock fitted to internal<br />
face<br />
Direct drive 1 7 1 7 Hopkins H75 pin lock fitted to internal<br />
face<br />
Reveal Tube motor 1 7 2 7 Hopkins H75 pin lock fitted to internal<br />
face<br />
Internal Tube motor 1 7 2 7 Hopkins H75 pin lock fitted to internal<br />
face<br />
Direct drive 1 7 2 7 Hopkins H75 pin lock fitted to internal<br />
face<br />
Note:<br />
1. The approval applies to the shutters when installed strictly in accordance with the instructions provided with the product.<br />
Shellcast Systems Limited<br />
Camel House, Six Ashes, Bridgnorth WV15 6ER, United Kingdom<br />
Tel: +44 (0)1562 750 700 • Fax: +44(0)8712 453 553<br />
E-mail: technical@shellcast-shutters.co.uk • Website: www.shellcast-shutters.co.uk<br />
Certificate No: 707a to LPS 1175: Issue 5<br />
Security Shutters<br />
Product<br />
Name<br />
Model Type Minimum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Linframe CD38.1 Built-in rolling<br />
shutter<br />
CD38.2 Built-in rolling<br />
shutter<br />
CD38.3 Built-in rolling<br />
shutter<br />
CD38/P.1 Built-in rolling<br />
shutter<br />
CD38/S.1 Built-in rolling<br />
shutter<br />
CD60.1 Built-in rolling<br />
shutter<br />
CD60.2 Built-in rolling<br />
shutter<br />
Minimum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Height<br />
(m)<br />
Maximum<br />
Clear<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0 0.4 6 5 1 707a/01<br />
0 0.4 6 5 2 707a/02<br />
0 0.4 6 5 3 (2) 707a/03<br />
0 0.4 6 3 1 707a/04<br />
0 0.4 6 3 1 707a/05<br />
0 0.4 6 5 1 707a/06<br />
0 0.4 6 5 2 707a/07<br />
Notes<br />
446 20 Nov 2011
PART 4: SECTION 5.6<br />
SECURITY SHUTTERS<br />
1. The approval applies to the shutters when installed strictly in accordance with the instructions provided with the product<br />
2. To achieve this grade the lockable override cover plate must be fitted and locked, and the key removed to a secure location.<br />
SWS UK<br />
Hornby Road, Claughton, Lancaster LA2 9LA, United Kingdom<br />
Tel: +44 (0)1524 772400 • Fax: +44 (0)1524 772411<br />
E-mail: info@swsuk.co.uk • Website: www.swsuk.co.uk<br />
Certificate No: 390a to LPS 1175: Issue 5.3<br />
Security Shutters<br />
Product Name Type Lath Minimum<br />
Height<br />
(m)<br />
SeceuroShield Roller<br />
7501 shutter<br />
SeceuroShield Roller<br />
3801<br />
SeceuroVision<br />
7501<br />
shutter<br />
Roller<br />
shutter<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
Solid 0.6 0.9 4.7 6 1 390a/04<br />
Solid 0.9 0.9 4 3 1 390a/02<br />
Perforated 0.6 0.9 4.7 6 1 390a/05<br />
Compatible Locking Devices and Method of Shutter Operation<br />
LPCB Ref.No. Product Name Type Operation<br />
Motorised Manual Simbac<br />
6C3.3227<br />
cylinder<br />
lock<br />
Lock<br />
Hopkins<br />
H75 pin<br />
lock<br />
390a/02 SeceuroShield 3801 Roller shutter<br />
390a/04 SeceuroShield 7501 Roller shutter<br />
390a/05 SeceuroVision 7501 Roller shutter<br />
<br />
1<br />
<br />
1<br />
<br />
Approved Accessories<br />
Accessory<br />
Associated Products (LPCB Ref. No. 390a/..)<br />
02 2 04 05<br />
Manual override handle <br />
Approved Installation Configurations 3 Brick Concrete Structural<br />
LPCB Ref. No.<br />
Product Name<br />
390a/02 SeceuroShield 3801<br />
390a/04 SeceuroShield 7501<br />
390a/05 SeceuroVision 7501<br />
Configuration<br />
Substrate<br />
Structural<br />
Steel Timber<br />
Reveal <br />
Internal face fixed <br />
External face fixed <br />
Reveal <br />
Internal face fixed <br />
Reveal <br />
Internal face fixed <br />
20 Nov 2011 447
PART 4: SECTION 5.6<br />
SECURITY SHUTTERS<br />
Notes<br />
1. The Hopkins H75 pin lock is only approved on shutters over 3m wide operated by a motor drive axle.<br />
2. The manual override option is only approved on internally face fixed units with internally face fixed motor boxes.<br />
3. This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.<br />
448 20 Nov 2011
PART 4: SECTION 5.7<br />
PERFORATED SECURITY SCREENS<br />
Perforated security screens (otherwise referred to as security screens and void protection screens) listed in<br />
this <strong>section</strong> are approved to LPS 1175 Requirements and testing procedures for the LPCB approval and<br />
listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers.<br />
In addition to approving security screens to LPS 1175, LPCB also offer security performance approval of such<br />
products to EN1627.<br />
SWS UK<br />
Hornby Road, Claughton, Lancaster LA2 9LA, United Kingdom<br />
Tel: +44 (0)1524 772400 • Fax: +44 (0)1524 772411<br />
E-mail: info@swsuk.co.uk • Website: www.swsuk.co.uk<br />
Certificate No: 390c/01 to LPS 1175: Issue 6<br />
Perforated Security Screens<br />
Product Name Type Minimum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert. No.<br />
SeceuroMesh Fixed security screen 0.25 0.25 2.54 1.29 1 390c/01<br />
Approved Installation Configurations (1)<br />
Configuration<br />
Substrate<br />
Structural Concrete Brick Timber<br />
Steel Blockwork<br />
External face <br />
Reveal <br />
Note<br />
1. This assumes installation direct to substrate and not via intermediate substrates.<br />
Trellicor (Pty) Limited<br />
20 Aberdare Drive, Phoenix Industrial Park, Durban, South Africa<br />
Tel: +27 31 500 4301 • Fax: +27 31 507 2129/3973<br />
Certificate No: 474a to LPS 1175: Issue 5<br />
Perforated Security Screens<br />
Product<br />
Name<br />
Model Type Minimum<br />
Height<br />
(m)<br />
Griffinguard Standard Fixed security<br />
Griffinguard<br />
(3)<br />
Double<br />
screen<br />
Fixed security<br />
screen<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.4 0.4 1.3 2.5 1 474a/03<br />
0.4 1.4 2.6 2.5 1<br />
Note<br />
1. The Griffinguard is approved for either externally face fixing or reveal mounting into brickwork, lightweight blockwork, concrete<br />
blockwork, structural steelwork or timber.<br />
20 Nov 2011 449
PART 4: SECTION 5.8<br />
LOUVRE VENTS<br />
Louvre vents listed within this <strong>section</strong> have been evaluated in accordance with LPS 1175 Specification for<br />
testing and classifying the burglary resistance of building components, strongpoints and security enclosures.<br />
Stafford Bridge Doors Limited<br />
Bedford Road, Pavenham, Bedford MK43 7PS, United Kingdom<br />
Tel: +44 (0)1234 826316 • Fax: +44 (0)1234 826319<br />
E-mail: sales@sbdoors.com • Website: www.surelockmcgillgroup.com/sbd<br />
Certificate No: 516b to LPS 1175: Issue 7<br />
Louvre Vents<br />
Product Name Type Minimum<br />
Louvre<br />
Height 1 (m)<br />
Maximum<br />
Louvre<br />
Height 1 (m)<br />
Minimum<br />
Louvre<br />
Width 2 (m)<br />
Maximum<br />
Louvre<br />
Width 2 (m)<br />
Security<br />
Rating<br />
Cert. No.<br />
SR4 Louvre Steel security louvre vent 0.35 2.5 0.35 1.15 4 516b/01<br />
Compatible Substrates 3<br />
Cert. No.<br />
516b/01<br />
Substrate<br />
Steelw ork<br />
Reinforced blockw ork<br />
Reinforced concrete<br />
Partition w all of ‘Wilton’ / ‘Halton’ construction via Sapele timber stud 4<br />
Partition w all of equivalent resistance to LPS 1175 SR4 via Sapele timber stud 4<br />
lining an aperture in steelw ork, reinforced blockw ork or reinforced concrete<br />
Notes:<br />
1. The height of the louvre vent is measured perpendicular to the plane of the louvre blades.<br />
2. The width of the louvre vent is measured in the plane of the louvre blades.<br />
3. The vents are approved for installation in accordance with the instructions contained in documents D11767.15 (revision I) and<br />
D11767.23 (revision B).<br />
4. Sapele timber stud should be at least 100 mm by 70 mm.<br />
Technocover Limited (incorporating TechnoRail and Strataform)<br />
Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom<br />
Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527<br />
E-mail: techadvice@technocover.co.uk • Website: www.technocover.co.uk<br />
Certificate No: 450h to LPS 1175: Issue 6<br />
Louvre Vents<br />
Product Type<br />
Name<br />
Louvre<br />
Vent<br />
Minimum<br />
Louvre Module<br />
Height (m)<br />
Maximum<br />
Louvre Module<br />
Height (m)<br />
Minimum<br />
Louvre Module<br />
Width (m)<br />
Maximum<br />
Louvre Module<br />
Width (m)<br />
Security<br />
Rating<br />
Modular<br />
0.2 1 1 0.6 1.2 1 5 450h/01<br />
system 1<br />
louvre vent<br />
Cert.<br />
No.<br />
Compatible Substrates<br />
LPCB Trade Name Type Installation method<br />
Compatible Substrates<br />
Ref. No.<br />
Reinforced Concrete Steelwork<br />
450h/01 Louvre Vent Modular louvre<br />
vent system<br />
Reveal fitting only <br />
Notes<br />
450 20 Nov 2011
PART 4: SECTION 5.8<br />
LOUVRE VENTS<br />
1. The louvre modules can be bolted together to form a larger panel. The bolted together panels can theoretically fill any<br />
structural opening larger than the smallest module.<br />
2. The Louvre Vent may also be fitted directly above the Technocover Sentinel UltraSecure doorsets listed on LPCB<br />
certificate 450f without compromising their Security Ratings to LPS 1175.<br />
20 Nov 2011 451
PART 4: SECTION 5.9<br />
GARAGE DOORS<br />
Theft of equipment from garages is fairly common due to the value of equipment often stored within them and<br />
the ease with which burglars can overcome many garage doors. Burglars also target garages that provide<br />
access to the inside of the house via internal pedestrian doors because the burglars can:<br />
attack the internal doorset unobserved by people in surrounding properties; and/or<br />
use tools stored within the garage to aid their entry into the house.<br />
Specifying garage doors that provide proven levels of resistance to forced entry therefore plays an important<br />
<strong>part</strong> in reducing:<br />
Theft of equipment from garages.<br />
Theft of items from houses resulting from entry through adjoining garages.<br />
Good physical security will also help to protect against attempted arson, especially if the garage doors have<br />
dual security and fire approval through LPCB.<br />
Garage doors listed in this <strong>section</strong> meet the requirements of LPS 1175 Requirements and testing procedures<br />
for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures<br />
and free-standing barriers.<br />
In addition to fitting garage doors approved to LPS 1175, specifiers keen to improve the security of their<br />
garages should also consider using security enclosures approved to LPS 1175 and fitting intruder detection<br />
equipment approved by LPCB and installed by a competent installer. Please refer to Section 4 for a list of<br />
approved security enclosures and Section 1 for a list of approved intruder detection equipment.<br />
LPCB also offer security performance approvals of garage doors to EN1627.<br />
Aluroll Limited<br />
Mile Oak Industrial Estate, Maesbury Road, Oswestry, Shropshire SY10 8GA, United Kingdom<br />
Tel: +44 (0)800 977 8975 • Fax: +44 (0)1691 671 482<br />
E-mail: enquiry@aluroll.co.uk • Website: www.aluroll.co.uk<br />
Certificate No: 931a to LPS 1175: Issue 6<br />
Garage Doors<br />
Product Type<br />
Name<br />
Elite<br />
Internally<br />
face fitted<br />
double skin<br />
insulated<br />
roller<br />
shutter<br />
Minimum<br />
Structural<br />
Opening<br />
Height (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Height (m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width (m)<br />
Maximum<br />
Door<br />
Area<br />
(m 2 )<br />
Compatible<br />
Locking<br />
Devices<br />
Security<br />
Rating<br />
0.9 5.2 0.9 5.0 20 B 1 931a/02<br />
Cert.<br />
No.<br />
Notes<br />
1 The Elite garage door is also marketed as a T77 Elite roller shutter. That is available over the same size range and<br />
with same locking devices.<br />
2 Refer to Volume 2 Part 4 Section 5.6 for full details of the locking systems and accessories approved on the T77 Elite<br />
roller shutter and other approved roller shutters manufactured by Aluroll Limited.<br />
452 20 Nov 2011
PART 4: SECTION 5.9<br />
GARAGE DOORS<br />
SWS UK<br />
Hornby Road, Claughton, Lancaster LA2 9LA, United Kingdom<br />
Tel: +44 (0)1524 772400 • Fax: +44 (0)1524 772411<br />
E-mail: info@swsuk.co.uk • Website: www.swsuk.co.uk<br />
Certificate No: 390b to LPS 1175: Issue 5.3<br />
Garage Doors<br />
Product Name Type Minimum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Security Rating<br />
Cert. No.<br />
SeceuroGlide Excel Garage door 1 1.5 3.85 5.2 1 390b/01<br />
Approved Accessories<br />
Accessory<br />
Associated Products (LPCB Ref. No. 390b/...)<br />
Bullet locks<br />
01<br />
<br />
Approved Installation Configurations<br />
Configuration<br />
Substrate<br />
Brick Blockwork Structural<br />
Steel<br />
Structural<br />
Timber<br />
Reveal 1 <br />
Internal face fixed 1 <br />
Notes<br />
1. This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.<br />
2. No assessment has been made of the remote control device.<br />
20 Nov 2011 453
PART 4: SECTION 6<br />
ACCESS COVERS AND HATCHES<br />
Many important facilities, especially those of utility companies, are unmanned and remote from the main<br />
business. At the request of the utility companies, access covers protecting items such as valves, switchgear<br />
and meters are now security rated to provide protection against malicious attack.<br />
LPCB approves access covers to LPS 1175 Requirements and testing procedures for the LPCB approval and<br />
listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers.<br />
The approval procedures and conditions that apply to access covers are the same as those that apply to<br />
security doors and shutters.<br />
It is important that specifiers only select access covers that are covered by the scope detailed on the<br />
certificate since products that fall outside that scope may not provide an equivalent level of security.<br />
It is also important to ensure that the products are installed in accordance with the manufacturer’s instructions<br />
and that all exposed fixings, the substrate into which the device is fitted and the locking mechanisms are<br />
regularly checked to ensure that they are in good condition and that they have not been tampered with.<br />
Products that have been certified by LPCB should be marked with a label indicating the grade of security<br />
offered, LPCB approval mark and certificate number.<br />
Aquacast (Fabrications) Limited<br />
Unit 3 Power Park, Towers Business Park, Rugeley, Staffordshire WS15 1UZ, United Kingdom<br />
Tel: +44 (0)1889 572620 • Fax: +44 (0)1889 572629<br />
E-mail: sales@aquacastltd.com • Website: www.aquacastltd.com<br />
Certificate No: 1020a to LPS 1175: Issue 7<br />
Horizontal Access Cover<br />
Product<br />
Name<br />
Type Minimum<br />
Length of<br />
Internal<br />
Opening (mm)<br />
Aquaguard Single leaf<br />
horizontal<br />
access cover<br />
Maximum<br />
Length of<br />
Internal<br />
Opening (mm)<br />
Minimum<br />
Width of<br />
Internal<br />
Opening (mm)<br />
Maximum<br />
Width of<br />
Internal<br />
Opening (mm)<br />
Security<br />
Rating<br />
Cert. No.<br />
250 1200 250 1200 4 1020a/01<br />
Compatible Padlocks 1,2<br />
Padlock Cylinder LPCB Cert. No. 1020a/01<br />
Abloy PL340/25 Abloy Protec <br />
Abloy PL340/25 Abloy High Profile <br />
Abloy PL340/25 Abloy Disklock Pro <br />
Abloy PL340/25 Abloy Exec <br />
Abloy PL342 Abloy Protec <br />
Abloy PL342 Abloy High Profile <br />
Abloy PL342 Abloy Disklock Pro <br />
Abloy PL342 Abloy Exec <br />
Abloy PL350/25 Abloy Protec <br />
Abloy PL350/25 Abloy High Profile <br />
Abloy PL350/25 Abloy Disklock Pro <br />
Abloy PL350/25 Abloy Exec <br />
Accessories 1<br />
454 20 Nov 2011
PART 4: SECTION 6<br />
ACCESS COVERS AND HATCHES<br />
Accessory Code LPCB Cert. No. 1020a/01<br />
Alarm bracket AB1 <br />
Cable holes 3 CH1 <br />
Extended frame and lid EX1 <br />
Ladder type safety grill FP1 <br />
Split type safety grill FP2 <br />
Extended low er shroud 4 LS1 <br />
Notes:<br />
1. Certification does not cover the use of padlocks or accessories other than those listed. Utilisation of unlisted padlocks and/or<br />
accessories may affect the level of security offered by the access cover.<br />
2. The ‘user friendliness’ of employing the padlocks listed has not been assessed as this is beyond the scope of LPS 1175: Issue 7.<br />
3. Cable holes (accessory CH1) are only available on access covers with the extended frame and lid (accessory EX1).<br />
4. The extended lower shroud (accessory LS1) must be used when the substrate onto which the access cover is mounted does not<br />
extend horizontally from the front of the main body of the access cover by at least 300 mm.<br />
5. The access cover is approved when installed in accordance with the instructions on document AG-LPS4-Fit (Revision 3, dated 2<br />
March 2011).<br />
Midas Technologies (GB) Limited<br />
Unit A, Roundhouse Close, Eastern Industry, Peterborough PE1 5TA, United Kingdom<br />
Tel: +44 (0)1733 342600 • Fax: +44 (0)1733 346672<br />
E-mail: sales@midastech.co.uk • Website: www.midastech.co.uk<br />
Certificate No: 421a to LPS 1175: Issue 5<br />
Horizontal Access Covers<br />
Product Name Type Minimum<br />
Internal<br />
Opening<br />
Length<br />
(mm)<br />
Maximum<br />
Internal<br />
Opening<br />
Length<br />
(mm)<br />
Minimum<br />
Internal<br />
Opening<br />
Width<br />
(mm)<br />
Maximum<br />
Internal<br />
Opening<br />
Width<br />
(mm)<br />
Security<br />
Rating<br />
Aquavent 2004 Single leaf horizontal access cover 200 1200 200 1200 4 421a/01<br />
Aquavent Single leaf (twin lid 1 ) horizontal 200 2000 200 2000 4 421a/02<br />
2004/TC<br />
access cover<br />
Aquavent<br />
2004/DC<br />
Double leaf horizontal access cover 1200 4000 1200 2000 4 421a/03<br />
Cert.<br />
No.<br />
Accessories<br />
Accessory<br />
Access Covers (LPCB Ref. No. 421a/..)<br />
01 02 03<br />
Safety grill/ladder<br />
<br />
Deep pan base frame <br />
Alarm bracket and switch plate <br />
Compatible Padlocks<br />
20 Nov 2011 455
PART 4: SECTION 6<br />
ACCESS COVERS AND HATCHES<br />
Padlock Designation<br />
Cylinder<br />
Access Covers (LPCB Ref. No. 421a/..)<br />
01 02 03<br />
Abloy PL240/25 Abloy High Profile <br />
Abloy PL240/25EX Abloy Exec <br />
Abloy PL240/25DP Abloy Disklock Pro <br />
Abloy PL240/25PT Abloy Protec <br />
Abloy PL242 Abloy High Profile <br />
Abloy PL242EX Abloy Exec <br />
Abloy PL242DP Abloy Disklock Pro <br />
Abloy PL242PT Abloy Protec <br />
Abloy PL250/25 Abloy High Profile <br />
Abloy PL250/25EX Abloy Exec <br />
Abloy PL250/25DP Abloy Disklock Pro <br />
Abloy PL250/25PT Abloy Protec <br />
Abloy PL340/25 Abloy High Profile <br />
Abloy PL340/25EX Abloy Exec <br />
Abloy PL340/25DP Abloy Disklock Pro <br />
Abloy PL340/25PT Abloy Protec <br />
Abloy PL342 Abloy High Profile <br />
Abloy PL342EX Abloy Exec <br />
Abloy PL342DP Abloy Disklock Pro <br />
Abloy PL342PT Abloy Protec <br />
Abloy PL350/25 Abloy High Profile <br />
Abloy PL350/25EX Abloy Exec <br />
Abloy PL350/25DP Abloy Disklock Pro <br />
Abloy PL350/25PT Abloy Protec <br />
Chubb 1K12c Chubb 6-pin <br />
Chubb 1K13c Chubb 6-pin <br />
Chubb 1K22c Chubb 6-pin <br />
Chubb 1K23c Chubb 6-pin <br />
ERA “Fortress” 977-91 ERA 6-pin <br />
Rotalok 60/12/ST N/A <br />
Rotalok 60/12/SE N/A <br />
Rotalocken 22RTLKNX Locken CL-PL2WR<br />
electronic cylinder<br />
<br />
Notes<br />
1. This model incorporates a secondary inner lid.<br />
2. Certification does not cover the use of padlocks or accessories other than those listed above. Utilisation of unlisted padlocks and/or<br />
accessories may affect the level of security offered by the access cover.<br />
3. The 'user friendliness' of employing the padlocks listed above has not been assessed as this is beyond the scope of LPS 1175:<br />
Issue 5.<br />
4. The resistance of the electronic cylinder to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175.<br />
Likewise, the assessment has not covered possible effects of any susceptibilities relating to the functionality and performance of the<br />
keys that may be used to operate the cylinder. It is therefore recommended that specifiers and installers satisfy themselves that the<br />
components used are either resistant to mechanical and other forms of tampering/abuse and are resistant to any environmental<br />
conditions/interference that may cause the padlock to disengage.<br />
Steelway Fensecure Limited t/a Steelway Brickhouse<br />
Brickhouse Lane, West Bromwich, West Midlands B70 0DY, United Kingdom<br />
Tel: +44 (0)121 521 4524 • Fax: +44 (0)121 521 4551<br />
E-mail: sales@steelwaybrickhouse.co.uk • Website: www.steelway.co.uk<br />
Certificate No: 645a to LPS 1175: Issue 5<br />
456 20 Nov 2011
PART 4: SECTION 6<br />
ACCESS COVERS AND HATCHES<br />
Horizontal Access Covers<br />
Product<br />
Type<br />
Name<br />
Sentry<br />
Single leaf horizontal<br />
access cover<br />
Single leaf horizontal valve<br />
cover<br />
Single leaf horizontal<br />
ventilator cover<br />
Twin leaf in-line hinged<br />
horizontal access cover<br />
Twin leaf end-hinged<br />
horizontal access cover<br />
Minimum<br />
Length of<br />
Internal<br />
Opening<br />
(mm)<br />
Maximum<br />
Length of<br />
Internal<br />
Opening<br />
(mm)<br />
Minimum<br />
Width of<br />
Internal<br />
Opening<br />
(mm)<br />
Maximum<br />
Width of<br />
Internal<br />
Opening<br />
(mm)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
300 1200 300 1100 4 645a/01<br />
200 300 200 300 4 645a/02<br />
200 500 200 500 4 645a/03<br />
1200 2200 600 1000 4 645a/04<br />
1200 2200 600 1500 4 645a/05<br />
Approved Accessories<br />
Accessory<br />
Sentry Access Cover (LPCB Ref. No. 645a/…)<br />
01 02 03 04 05<br />
Safety grid 1 <br />
Safety grid/Exit support 1 <br />
Alarm Bracket <br />
Junction box bracket <br />
External seal version<br />
<br />
External vent and seal version <br />
Compatible Padlocks<br />
Padlock Designation Cylinder<br />
Sentry Access Cover (LPCB Ref. No. 645a/…)<br />
01 02 03 04 05<br />
Abloy PL250/25 Abloy High Profile <br />
Abloy PL250/25EX Abloy Exec <br />
Abloy PL250/25DP Abloy Disklock Pro <br />
Abloy PL250/25PT Abloy Protec <br />
Abloy PL350/25 Abloy High Profile <br />
Abloy PL350/25EX Abloy Exec <br />
Abloy PL350/25DP Abloy Disklock Pro <br />
Abloy PL350/25PT Abloy Protec <br />
Chubb 1K23c Chubb 6-pin <br />
Kaba KP15.0000C5-RB20 Kaba 20 (Armoured) 2 <br />
Rotalok 60/12/ST Abloy Exec <br />
Rotalok 60/12/ST Abloy Disklock Pro <br />
Rotalok 60/12/ST Abloy Protec <br />
Rotalok 60/12/ST Assa Twin-Combi <br />
Rotalok 60/12/ST Kaba 20 (Armoured) 2 <br />
Rotalok 60/12/ST Kaba 20 (standard) 2 <br />
Notes<br />
1. The safety grid/exit support is only available on access covers with an internal clear opening length of at least 400mm.<br />
2. The torque resistant version of the Kaba 20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders.<br />
20 Nov 2011 457
PART 4: SECTION 6<br />
ACCESS COVERS AND HATCHES<br />
Technocover Limited (incorporating TechnoRail and Strataform)<br />
Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom<br />
Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527<br />
E-mail: techadvice@technocover.co.uk • Website: www.technocover.co.uk<br />
Certificate No: 450a to LPS 1175: Issue 5<br />
Horizontal Access Covers<br />
Product Name Type Minimum<br />
Internal<br />
Opening<br />
Length<br />
(mm)<br />
Ultra Secure DV<br />
Single leaf horizontal<br />
Ultra Secure DV (Small Lock)<br />
Ultra Secure DV4 Twin Leaf<br />
(End Hinged)<br />
Ultra Secure DV4 Twin Leaf<br />
(In-line Hinged)<br />
Ultra Secure DV4 Triple Leaf<br />
(In-line Hinged)<br />
Ultra Secure DV4 Triple Leaf<br />
(Special)<br />
SHH1/DV<br />
SHH2/DV<br />
SHH3/DV<br />
SHHM/DV<br />
Maximum<br />
Internal<br />
Opening<br />
Length<br />
(mm)<br />
Minimum<br />
Internal<br />
Opening<br />
Width<br />
(mm)<br />
Maximum<br />
Internal<br />
Opening<br />
Width<br />
(mm)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
8 150 1100 150 1100 4 450a/01<br />
Single leaf horizontal 150 1100 150 1100 4 450a/02<br />
access cover 8<br />
Twin leaf horizontal 1100 2200 1100 1800 4 450a/04<br />
access cover 8<br />
Twin leaf horizontal 1100 2400 600 1100 4 450a/05<br />
access cover 8<br />
Triple leaf horizontal 1800 3600 600 1100 4 450a/06<br />
access cover 8<br />
Triple leaf horizontal 1800 3600 1100 1800 4 450a/07<br />
access cover 8<br />
Single leaf flush access 400 1200 400 1200 3 450a/09<br />
cover<br />
Twin leaf flush access 1200 2400 400 1200 3 450a/10<br />
cover<br />
Triple leaf flush access 1500 3000 400 1200 3 450a/11<br />
cover<br />
Multiple leaf flush 2000 12000 7 2000 2400 3 450a/12<br />
access cover<br />
Compatible Padlocks<br />
Padlock Designation Cylinder<br />
Access Covers (LPCB Ref. No. 450a/..)<br />
01 02 04 05 06 07 09 10 11 12<br />
Abloy PL240/25 Abloy High Profile <br />
Abloy PL240/25EX Abloy Exec <br />
Abloy PL240/25DP Abloy Disklock Pro <br />
Abloy PL240/25PT Abloy Protec <br />
Abloy PL250/25 Abloy High Profile <br />
Abloy PL250/25EX Abloy Exec <br />
Abloy PL250/25DP Abloy Disklock Pro <br />
Abloy PL250/25PT Abloy Protec <br />
Abloy PL340/25 Abloy High Profile <br />
Abloy PL340/25EX Abloy Exec <br />
Abloy PL340/25DP Abloy Disklock Pro <br />
Abloy PL340/25PT Abloy Protec <br />
Abloy PL342/25 Abloy High Profile <br />
Abloy PL342/25EX Abloy Exec <br />
Abloy PL342/25DP Abloy Disklock Pro <br />
Abloy PL342/25PT Abloy Protec <br />
Abloy PL350/25 Abloy High Profile <br />
Abloy PL350/25EX Abloy Exec <br />
458 20 Nov 2011
PART 4: SECTION 6<br />
ACCESS COVERS AND HATCHES<br />
Abloy PL350/25DP Abloy Disklock Pro <br />
Abloy PL350/25PT Abloy Protec <br />
Chubb 1K22c Chubb 6-pin <br />
Chubb 1K23c Chubb 6-pin <br />
Kaba K20SS65L Kaba 20 (Armoured) 4 <br />
Kaba K20SS65CL Kaba 20 (Armoured) 4 <br />
Kaba KP15.0000C5-RB Kaba 20 (Armoured) 4 <br />
Rotalok 60/12/ST Abloy Disclock Pro <br />
Rotalok 60/12/ST Abloy Exec <br />
Rotalok 60/12/ST Abloy Protec <br />
Rotalok 60/12/ST Assa Twin-Combi <br />
Rotalok 60/12/ST Kaba 20 (Armoured) 4 <br />
Rotalok 60/12/ST Kaba 20 (Armoured) 4 <br />
Accessories<br />
Accessory<br />
Access Covers (LPCB Ref. No. 450a/..)<br />
01 02 04 05 06 07 09 10 11 12<br />
F3 skirting frame <br />
K2 Hasp and staple <br />
Viper alarm bracket <br />
Ladder/safety grid <br />
400 x 50 mm inner frame ventilation holes <br />
Standard vent option <br />
Maxi vent option <br />
Undercover bracing 'A15' option <br />
Undercover bracing 'B125' option <br />
Undercover bracing 'C250' option <br />
Notes<br />
1. The Abloy PL240/25 and PL340/25 padlocks should only be used on Ultra Secure DV access covers that have been fitted with the<br />
K2 hasp and staple.<br />
2. The Abloy PL250/25, PL350/25 and Chubb 1K23c padlocks should not be used on Ultra Secure DV access covers that have been<br />
fitted with the K2 hasp and staple.<br />
3. If the Abloy PL250/25 and PL350/25 padlocks are to be fitted to access covers on upstands greater than 250 mm tall, the horizontal<br />
distance between the locking face of the access cover and the outside edge of the upstand must be at least 200 mm.<br />
4. The torque resistant version of the Kaba 20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders.<br />
5. Certification does not cover the use of padlocks or accessories other than those listed above. Utilisation of unlisted padlocks and/or<br />
accessories may affect the level of security offered by the access cover.<br />
6. The 'user friendliness' of employing the padlocks listed above has not been assessed as this is beyond the scope of LPS 1175:<br />
Issue 5.<br />
7. The configurations of multi leaf access covers falling within the scope of this approval are defined on Technocover document<br />
SHH/DV/ASSY-08 dated 12 September 2006.<br />
8. This product is available with or without an inner lid. This does not effect the security rating of the product.<br />
20 Nov 2011 459
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
Walling systems listed in this <strong>section</strong> are approved to LPS 1175 Requirements and testing procedures for the<br />
LPCB approval and listing or intruder resistant building components, strongpoints, security enclosures and<br />
free-standing barriers.<br />
In order to comply with the terms of the approval, the walling systems must be designed and installed in<br />
accordance with the relevant system manuals noted within the product entry.<br />
Unless otherwise stated, the approvals cover:<br />
Plain systems (that is, excluding service penetrations, ducts or other openings such as doors and<br />
windows).<br />
Resistance to the creation of an access hole, within the area of the barrier, through which it is<br />
possible to pass the 225 mm by 400 mm elliptical test block defined in LPS 1175.<br />
It is recommended that evidence is sought to confirm compatibility of any doors, windows etc to ensure the<br />
combined assembly offers the required security rating. Where such compatibility has been proven, this is<br />
indicated in the relevant listing.<br />
Isoclad Limited<br />
10 Alder Road, West Chirton North Industrial Estate, North Shields, Tyne & Wear NE29 8SD, United Kingdom<br />
Tel: +44 (0)191 258 5052 • Fax: +44 (0)191 259 5742<br />
E-mail: sales@isoclad.co.uk • Website: www.isoclad.co.uk<br />
Certificate No: 142d to LPS 1175: Issue 6<br />
Secure Partition Walling System<br />
Product<br />
Name<br />
Product Type Minimum<br />
Height (m)<br />
Maximum<br />
Height (m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
Securiclad Walls with<br />
2.5 Unlimited 2.5 Unlimited 3 142d/01<br />
horizontally laid<br />
panels<br />
Walls with vertically 2.5 6.0 0.25 Unlimited 3<br />
laid panels<br />
Walls with<br />
2.5 Unlimited 2.5 Unlimited 4 142d/02<br />
horizontally laid<br />
panels<br />
Walls with vertically<br />
laid panels<br />
2.5 6.0 0.25 Unlimited 4<br />
System Components<br />
Component Type<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Thickness<br />
(m)<br />
SR3/SR4 panel (mineral w ool) 0.25 1.19 2.5 6 0.1<br />
Ceiling panel (mineral w ool) 0.25 1.19 1 6 0.1<br />
SR3/SR4 panel (PIR) 0.25 1.19 2.5 6 0.1<br />
Ceiling panel (PIR) 0.25 1.19 1 6 0.1<br />
Products Compatible with the Securiclad Security Panel System 2,3<br />
460 20 Nov 2011
Manufacturer Product Name Product Type LPCB<br />
Certificate<br />
Number<br />
Ascot Doors<br />
Limited<br />
Centurion A363S<br />
Centurion A363D<br />
Single leaf outw ard<br />
opening doorset<br />
Double leaf outw ard<br />
opening doorset<br />
Benw eldSecure Bew dley doorset Single leaf outw ard<br />
opening doorset<br />
Pow ershield Pow ershield Class Single leaf outw ard<br />
Doors Limited 3 single<br />
opening doorset<br />
Selectaglaze<br />
Limited<br />
Professional<br />
Barriers Limited<br />
Ascot Doors<br />
Limited<br />
Pow ershield<br />
Doors Limited<br />
Pow ershield Class<br />
3 double<br />
Double leaf outw ard<br />
opening doorset<br />
Security<br />
Rating<br />
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
Compatible Locking<br />
Systems<br />
Active Leaf Passive<br />
Leaf<br />
N/A<br />
131d/04 3 12, 13, 15,<br />
16, 18 and<br />
19<br />
131d/05 3 12, 13, 15,<br />
16, 18 and<br />
19<br />
34, 35 and<br />
36<br />
746a/01 3 1 N/A<br />
852a/01 3 2 to 11,<br />
13,16,17 and<br />
19<br />
N/A<br />
852a/02 3 2 to 11, 32<br />
13,16,17 and<br />
19<br />
683a/06 3 N/A N/A<br />
Series 55’ level 3’ Fixed light security<br />
w indow<br />
Extendor Eclipse Collapsible grille 869a/01 3 33 N/A<br />
Centurion A355<br />
Centurion A364S<br />
Centurion A364D<br />
Pow ershield Class<br />
4 single<br />
Pow ershield Class<br />
4 double<br />
Single leaf outw ard<br />
opening doorset<br />
Single leaf outw ard<br />
opening doorset<br />
Double leaf outw ard<br />
opening doorset<br />
Single leaf outw ard<br />
opening doorset<br />
Double leaf outw ard<br />
opening doorset<br />
131d/01 4 13 N/A<br />
131d/02 4 13, 16, 19,<br />
27, 29 and<br />
31<br />
131d/03 4 13, 16, 19,<br />
27, 29 and<br />
31<br />
852a/03 4 3, 5, 7, 9, 10,<br />
13, 16, 19,<br />
20, 21, 22,<br />
23, 24, 26,<br />
28 and 30<br />
852a/04 4 3, 5, 7, 9, 10,<br />
13, 16, 19,<br />
20, 21, 22,<br />
23, 24, 26,<br />
28 and 30<br />
N/A<br />
34, 35 and<br />
36<br />
N/A<br />
32<br />
Compatible Locking Systems for Products Compatible with the Securiclad Security Panel System<br />
20 Nov 2011 461
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
Compatible<br />
Locking<br />
Systems<br />
1 Assa 9787 Single point mortice<br />
hook lock<br />
2 MICO 942-3L EPC INT<br />
AD / HSCH 3<br />
3 MICO 942-3L EPC INT<br />
AD<br />
4 MICO 942-3 EPC INT<br />
MD / HSCH 3<br />
5 MICO 942-3 EPC INT<br />
MD<br />
6 MICO 942-3P EPC INT<br />
MD / HSCH 3<br />
7 MICO 942-3P EPC INT<br />
MD<br />
8 MICO 942-3L EPC INT<br />
MD / HSCH 3<br />
Model Type Operation Com patible<br />
Cylinders<br />
Entry<br />
Exit<br />
3-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
3-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
Key<br />
Europrofile<br />
cylinder w ithin<br />
the HSCH 3<br />
cylinder guard<br />
and lever handle<br />
None<br />
3-w ay locking Europrofile<br />
system w ith manual cylinder w ithin<br />
deadlock<br />
the HSCH 3<br />
cylinder guard<br />
and lever handle<br />
3-w ay locking None<br />
system w ith manual<br />
deadlock<br />
3-w ay locking Europrofile<br />
system w ith manual cylinder w ithin<br />
deadlock<br />
the HSCH 3<br />
cylinder guard<br />
and lever handle<br />
3-w ay locking None<br />
system w ith manual<br />
deadlock<br />
3-w ay locking Europrofile<br />
system w ith manual cylinder w ithin<br />
deadlock<br />
the HSCH 3<br />
cylinder guard<br />
and lever handle<br />
Key via an Assa<br />
256 (Assa<br />
Classic)<br />
combined<br />
cylinder ring and<br />
thumbturn<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
lever handle<br />
Europrofile<br />
cylinder<br />
(key:key)and<br />
lever handle<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
panic exit push<br />
plate<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
panic exit push<br />
plate<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
push pad<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
push pad<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
lever handle<br />
Q or R<br />
A, B, C, D, E<br />
or F<br />
-<br />
A, B, C, D, E<br />
or F<br />
-<br />
A, B, C, D, E<br />
or F<br />
-<br />
A, B, C, D, E<br />
or F<br />
9 MICO 942-3L EPC INT<br />
MD<br />
3-w ay locking None<br />
system w ith manual<br />
deadlock<br />
10 MICO 942-3L INT AD 3-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
None<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
lever handle<br />
Scandinavian<br />
oval cylinder and<br />
lever handle<br />
-<br />
-<br />
462 20 Nov 2011
11 MICO 942-3 INT MD / 3-w ay locking Scandinavian Scandinavian G, H, I, J, K, L,<br />
HSCH 3<br />
system w ith manual oval cylinder oval cylinder M, N or P<br />
12 deadlock<br />
w ithin the HSCH and panic exit G<br />
3 cylinder guard push plate<br />
and lever handle<br />
13 MICO 942-3 INT MD 3-w ay locking None<br />
system w ith manual<br />
deadlock<br />
16 MICO 942-3P INT MD 3-w ay locking<br />
system w ith manual<br />
deadlock<br />
None<br />
MICO 942-3L INT MD / 3-w ay locking Scandinavian<br />
HSCH 3<br />
system w ith manual oval cylinder<br />
deadlock<br />
w ithin the HSCH<br />
3 cylinder guard<br />
and lever handle<br />
Scandinavian<br />
oval cylinder<br />
and panic exit<br />
push plate<br />
Scandinavian<br />
oval cylinder<br />
and push pad<br />
14 MICO 942-3P INT MD / 3-w ay locking Scandinavian<br />
G, H, I, J, K, L,<br />
HSCH 3<br />
system w ith manual oval cylinder<br />
M, N or P<br />
15 deadlock<br />
w ithin the HSCH<br />
G<br />
3 cylinder guard<br />
and lever handle<br />
Scandinavian<br />
oval cylinder<br />
and push pad<br />
17 Scandinavian G, H, I, J, K, L,<br />
oval cylinder M, N or P<br />
18 and lever handle G<br />
19 MICO 942-3L INT MD 3-w ay locking<br />
system w ith manual<br />
deadlock<br />
None<br />
20 MICO 942-3L EPC INT<br />
AD / HSCH 4<br />
21 MICO 942-3 EPC INT<br />
MD / HSCH 4<br />
22 MICO 942-3P EPC INT<br />
MD / HSCH 4<br />
23 MICO 942-3L EPC INT<br />
MD / HSCH 4<br />
3-w ay locking<br />
system w ith<br />
automatic<br />
deadlocking<br />
Europrofile<br />
cylinder w ithin<br />
the HSCH 4<br />
cylinder guard<br />
and lever handle<br />
3-w ay locking Europrofile<br />
system w ith manual cylinder w ithin<br />
deadlock<br />
the HSCH 4<br />
cylinder guard<br />
and lever handle<br />
3-w ay locking Europrofile<br />
system w ith manual cylinder w ithin<br />
deadlock<br />
the HSCH 4<br />
cylinder guard<br />
and lever handle<br />
3-w ay locking Europrofile<br />
system w ith manual cylinder w ithin<br />
deadlock<br />
the HSCH 4<br />
cylinder guard<br />
and lever handle<br />
3-w ay locking Scandinavian<br />
system w ith oval cylinder<br />
automatic<br />
w ithin the HSCH<br />
deadlocking 4 cylinder guard<br />
and lever handle<br />
Scandinavian<br />
oval cylinder<br />
and lever handle<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
lever handle<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
panic exit push<br />
plate<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
push pad<br />
Europrofile<br />
cylinder<br />
(key:key) and<br />
lever handle<br />
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
-<br />
-<br />
-<br />
A, B, C, D, E<br />
or F<br />
A, B, C, D, E<br />
or F<br />
A, B, C, D, E<br />
or F<br />
A, B, C, D, E<br />
or F<br />
24 MICO 942-3L INT AD /<br />
Scandinavian G, H, I, J, K, L,<br />
HSCH 4<br />
oval cylinder M, N or P<br />
25 and lever handle G<br />
20 Nov 2011 463
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
26 MICO 942-3 INT MD / 3-w ay locking Scandinavian Scandinavian G, H, I, J, K, L,<br />
HSCH 4<br />
system w ith manual oval cylinder oval cylinder M, N or P<br />
27 deadlock<br />
w ithin the HSCH and panic exit G<br />
4 cylinder guard push plate<br />
and lever handle<br />
28 MICO 942-3P INT MD / 3-w ay locking Scandinavian Scandinavian G, H, I, J, K, L,<br />
HSCH 4<br />
system w ith manual oval cylinder oval cylinder M, N or P<br />
29 deadlock<br />
w ithin the HSCH and push pad G<br />
4 cylinder guard<br />
and lever handle<br />
30 MICO 942-3L INT MD / 3-w ay locking Scandinavian Scandinavian G, H, I, J, K, L,<br />
HSCH 4<br />
system w ith manual oval cylinder oval cylinder M, N or P<br />
31 deadlock<br />
w ithin the HSCH and lever handle G<br />
4 cylinder guard<br />
and lever handle<br />
32 M0455 Surface mounted<br />
barrel bolts<br />
33 Extendor Eclipse<br />
CL03 w ith CL03<br />
cylinder guard<br />
34 MICO 942 2-w ay panic exit<br />
35 MICO 942P 2-w ay emergency<br />
36 MICO 942L 2-w ay emergency<br />
exit device<br />
- - -<br />
- Europrofile<br />
cylinder w ithin<br />
Key (w hen<br />
internal locking<br />
S, T or U<br />
the CL03 cylinder version only)<br />
guard<br />
- Panic bar -<br />
device<br />
- Push pad -<br />
exit device<br />
- Lever handle -<br />
Compatible Cylinders for Products Compatible with the Securiclad Security Panel System<br />
Cylinder<br />
Reference<br />
Manufacturer Model<br />
Type<br />
A Abloy Protec CY304 Double Europrofile cylinder (key:key)<br />
B Abloy Disclock Pro CY304 Double Europrofile cylinder (key:key)<br />
C ASSA Tw in 7622 Double Europrofile cylinder (key:key)<br />
D ASSA C5822 Double Europrofile cylinder (key:key)<br />
E ASSA 4822 Double Europrofile cylinder (key:key)<br />
F Kaba Quattro S Euro Double Europrofile cylinder (key:key)<br />
G ASSA 4807 Half Scandinavian oval mechanical cylinder<br />
H ASSA Tw in 7607 Half Scandinavian oval mechanical cylinder<br />
I ASSA C5807 Half Scandinavian oval mechanical cylinder<br />
J ASSA 4407 Half Scandinavian oval mechanical cylinder<br />
K Abloy Protec CY201PT Half Scandinavian oval mechanical cylinder<br />
L Locken CL-PL2WR Half Scandinavian oval mechatronic cylinder<br />
M Kaba Quattro S Oval Half Scandinavian oval mechanical cylinder<br />
N Kaba K20 Oval Half Scandinavian oval mechanical cylinder<br />
O Abloy Disclock Pro CY201DP Half Scandinavian oval mechanical cylinder<br />
464 20 Nov 2011
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
P ASSA 4801 Half Scandinavian oval mechanical cylinder<br />
Q ASSA C5801 Half Scandinavian oval mechanical cylinder<br />
R ASSA C5803 Half Scandinavian oval mechanical cylinder<br />
S ASSA dp4400 Single Europrofile cylinder (key)<br />
T CISA AP3S Single Europrofile cylinder (key)<br />
U Kaba Quattro Plus Single Europrofile cylinder (key)<br />
Notes:<br />
1. The Securiclad panel systems must be installed in accordance with the approved Securiclad design manual (ISO/SECG04/02/11) and<br />
compatible product list (ISO/SEC/DSP/15/9/10).<br />
2. The Security Rating attributed to the compatible product must be at least that of the wall in which it is to be fitted. For example, a<br />
Security Rating 3 doorset shall not be used to form <strong>part</strong> of a Security Rating 4 wall.<br />
3. Refer to notes contained within the relevant certificate/Red Book entries for these products for details of restrictions on their use.<br />
Lowrey Contractors Limited<br />
200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom<br />
Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111<br />
E-mail: lowrey@talk21.com • Website: www.lowrey-contractors.co.uk<br />
Certificate No: 974c to LPS 1175: Issue 7<br />
Secure Partitioning Systems<br />
Product<br />
Name<br />
Product<br />
Type<br />
Minimum<br />
Height<br />
(m)<br />
Lowrey<br />
Level 1<br />
Security<br />
Mesh<br />
Panel<br />
System<br />
Lowrey<br />
Level 2<br />
Security<br />
Mesh<br />
Panel<br />
System<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Security<br />
Rating<br />
Partition 0.5 2 3.8 0.5 3 Unlimited N/A N/A 1 974c/01<br />
walls 1<br />
formed from<br />
wall panels<br />
supported by<br />
existing<br />
adjacent<br />
Partition 0.61 4 3.91 0.5 3 Unlimited 0.5 4.0 1<br />
walls 1<br />
formed from<br />
wall and<br />
ceiling panels<br />
supported by<br />
existing<br />
adjacent<br />
Ceiling<br />
formed from<br />
ceiling panels<br />
N/A N/A 0.5 Unlimited 0.5 4.0 1<br />
Partition 0.5 2 3.8 0.5 3 Unlimited N/A N/A 2 974c/02<br />
walls 1<br />
formed from<br />
wall panels<br />
supported by<br />
existing<br />
adjacent<br />
Partition 0.61 4 3.91 0.5 3 Unlimited 0.5 4.0 2<br />
walls 1<br />
formed from<br />
wall and<br />
ceiling panels<br />
supported by<br />
existing<br />
adjacent<br />
Ceiling N/A N/A 0.5 Unlimited 0.5 4.0 2<br />
formed from<br />
ceiling panels<br />
Cert.<br />
No.<br />
20 Nov 2011 465
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
Product<br />
Name<br />
Lowrey<br />
Level 3<br />
Security<br />
Mesh<br />
Panel<br />
System<br />
Product<br />
Type<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Security<br />
Rating<br />
Partition 0.5 2 3.8 0.5 3 Unlimited N/A N/A 3 974c/03<br />
walls 1<br />
formed from<br />
wall panels<br />
supported by<br />
existing<br />
adjacent<br />
Partition 0.61 4 3.91 0.5 3 Unlimited 0.5 4.0 3<br />
walls 1<br />
formed from<br />
wall and<br />
ceiling panels<br />
supported by<br />
existing<br />
adjacent<br />
Ceiling<br />
formed from<br />
ceiling panels<br />
N/A N/A 0.5 Unlimited 0.5 4.0 3<br />
Cert.<br />
No.<br />
System Components<br />
Com ponent Type Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Wall panel Mesh w all panel 0.25 2.4 0.5 1.5 N/A N/A<br />
Ceiling panel Mesh ceiling panel N/A N/A 0.25 1.5 0.25 3.8<br />
Support post<br />
Corner post<br />
Doorsets 5<br />
Support post for<br />
w alling system<br />
270 degree corner<br />
post for w alling<br />
system<br />
90 degree corner<br />
post for w alling<br />
system<br />
Single leaf outw ard<br />
opening doorset<br />
Double leaf outw ard<br />
opening doorset<br />
0.5 3.8 0.215 0.215 N/A N/A<br />
0.5 3.8 0.125 0.125 N/A N/A<br />
0.5 3.8 0.11 0.11 N/A N/A<br />
Refer to ‘Low rey Level 1, 2 and 3’ single leaf mesh security doorsets (LPCB<br />
Ref. No. 974a/01, 03 and 05) for scope of approval.<br />
Refer to ‘Low rey Level 1, 2 and 3’ double leaf mesh security doorsets (LPCB<br />
Ref. No. 974a/02, 04 and 06) for scope of approval.<br />
Notes:<br />
1. The walling system can either be constructed as a straight walling system or incorporate 90 or 270 degree angles. This angle is<br />
measured between the attack faces of the two adjacent panels.<br />
2. The minimum height of <strong>part</strong>itioning systems incorporating doorsets is 1.0 m.<br />
3. The minimum width of walls incorporating doorsets is 0.63 m.<br />
4. The minimum height of <strong>part</strong>itioning systems formed with a ceiling and incorporating doorsets is 1.1 m.<br />
5. The doorsets are not designed to be fitted within the ceiling system<br />
6. The <strong>part</strong>itioning system’s resistance relies on the supporting substrate offering compatible resistance to manual attack.<br />
7. The Lowrey security mesh panel systems are approved when installed in accordance with the instructions detailed in Lowrey’s<br />
document E-INST003 (Issue 4).<br />
Certificate No: 974f to LPS 1175: Issue 7<br />
Secure Partitioning Systems<br />
Product<br />
Name<br />
Product<br />
Type<br />
Minimum<br />
Height<br />
(m)<br />
Lowrey<br />
Level 4<br />
Security<br />
Solid<br />
Panel<br />
System<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Security<br />
Rating<br />
Partition<br />
formed from<br />
wall panels<br />
supported by<br />
existing<br />
adjacent<br />
walls 1 0.5 2 3.8 0.5 3 Unlimited N/A N/A 4 974f/01<br />
Cert.<br />
No.<br />
466 20 Nov 2011
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
Product<br />
Name<br />
Product<br />
Type<br />
Partition<br />
formed from<br />
wall and<br />
ceiling panels<br />
supported by<br />
existing<br />
adjacent<br />
Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width (m)<br />
Maximum<br />
Width (m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
walls 1 0.61 4 3.91 0.5 3 Unlimited 0.5 4.0 4<br />
Ceiling<br />
formed from<br />
ceiling panels<br />
Security<br />
Rating<br />
N/A N/A 0.5 Unlimited 0.5 4.0 4<br />
Cert.<br />
No.<br />
System Components<br />
Component Type Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Wall panel Solid w all panel 0.25 2.4 0.5 1.5 N/A N/A<br />
Ceiling panel Solid ceiling panel N/A N/A 0.25 1.5 0.25 3.8<br />
Support post<br />
Corner post<br />
Doorsets 6<br />
Support post for<br />
w alling system<br />
270 degree<br />
corner post for<br />
w alling system<br />
90 degree corner<br />
post for w alling<br />
system<br />
Single leaf<br />
outw ard opening<br />
plain leaf doorset<br />
Double leaf<br />
outw ard opening<br />
plain leaf doorset<br />
0.5 3.8 0.215 0.215 N/A N/A<br />
0.5 3.8 0.125 0.125 N/A N/A<br />
0.5 3.8 0.11 0.11 N/A N/A<br />
Refer to ‘Low rey Level 4’ single leaf security doorsets (LPCB Ref. No.<br />
974d/01) for scope of approval.<br />
Refer to ‘Low rey Level 4’ double leaf security doorsets (LPCB Ref. No.<br />
974d/02) for scope of approval.<br />
Notes:<br />
1. The walling system can either be constructed as a straight walling system or incorporate 90 or 270 degree angles in the wall line. This<br />
angle is measured between the attack faces of the two adjacent panels.<br />
2. The minimum height of <strong>part</strong>itioning systems incorporating doorsets is 1.0 m.<br />
3. The minimum width of walls incorporating doorsets is 0.63 m.<br />
4. The minimum height of <strong>part</strong>itioning systems formed with a ceiling and incorporating doorsets is 1.1 m.<br />
5. The doorsets are not designed to be fitted within the ceiling system.<br />
6. The <strong>part</strong>itioning system’s resistance relies on the supporting substrate offering compatible resistance to manual attack.<br />
7. The Lowrey security solid panel systems are approved when installed in accordance with the instructions detailed in Lowrey’s<br />
document E-INST003 (Issue 4).<br />
MultiSteel Limited<br />
MultiSteel House, 117-119 Brent Terrace, London NW2 1LL, United Kingdom<br />
Tel: +44 (0)20 8208 8300 • Fax: +44 (0)20 8208 8209<br />
E-mail: office@multisteel.co.uk • Website: www.multisteel.co.uk<br />
Certificate No: 818b to LPS 1175: Issue 6<br />
20 Nov 2011 467
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
Modular Security Screen<br />
Product Name Type Minimum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
Multisteel 'Security<br />
Screen'<br />
Maximum<br />
Structural<br />
Opening<br />
Height<br />
(m)<br />
Minimum<br />
Structural<br />
Opening<br />
Width<br />
(m)<br />
Maximum<br />
Structural<br />
Opening<br />
Width<br />
(m)<br />
Security<br />
Rating<br />
Modular security 1.9 5 0.79 4 1 818b/01<br />
doorset 2, 3<br />
screen 1<br />
with access control<br />
Modular security 1.9 5 0.7 4 2<br />
doorset 4<br />
screen 1<br />
with deadlocking<br />
Modular security<br />
screen 5 1.9 5 2 6 2<br />
Cert.<br />
No.<br />
Notes<br />
1. The security screens are available with glazed and opaque panels.<br />
2. The access control system’s resistance to “non-mechanical” attack has not been assessed as it is outside the scope of<br />
LPS 1175. It is therefore recommended that specifiers satisfy themselves that the components used are resistant to any<br />
environmental conditions/interference that may cause the locking system to disengage.<br />
3. Refer to LPCB certificate number 818a for full details of the Multisteel ‘Mag Lock’ doorset (LPCB reference number<br />
818a/01).<br />
4. Refer to LPCB certificate number 818a for full details of the Multisteel ‘3 Point Mul-T-Lock’ doorset (LPCB reference<br />
number 818a/02).<br />
5. This configuration does not incorporate any doorsets.<br />
Technocover Limited (incorporating TechnoRail and Strataform)<br />
Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom<br />
Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527<br />
E-mail: techadvice@technocover.co.uk • Website: www.technocover.co.uk<br />
Certificate No: 450k to LPS 1175: Issue 7<br />
Secure Partitioning System<br />
Product Name Product<br />
Type<br />
Minimum<br />
Height<br />
(m)<br />
Ultrasecure<br />
security mesh<br />
panel system<br />
Walling<br />
system<br />
Ceiling<br />
system<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
0.50 1 6 0.50 2 Unlimited N/A N/A 3 450k/01<br />
N/A N/A 0.50 Unlimited 0.50 6 3<br />
System Components<br />
468 20 Nov 2011
Component Type Minimum<br />
Height<br />
(m)<br />
Maximum<br />
Height<br />
(m)<br />
Minimum<br />
Width<br />
(m)<br />
Maximum<br />
Width<br />
(m)<br />
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
Minimum<br />
Length<br />
(m)<br />
Maximum<br />
Length<br />
(m)<br />
Wall panel Mesh wall panel 0.50 6 0.25 1 N/A N/A<br />
Ceiling panel Mesh ceiling panel N/A N/A 0.25 1 0.50 6<br />
Support post<br />
Corner post<br />
Doorsets<br />
Notes<br />
Support post for<br />
walling system 3 0.46 5.91 0.165 0.165 N/A N/A<br />
Corner post for<br />
0.50 6 0.13 0.13 N/A N/A<br />
walling system 3<br />
Single leaf outward Refer to Ultrasecure SCD1 mesh security doorset (LPCB Ref. No.<br />
opening doorset<br />
Double leaf outward<br />
opening doorset<br />
450j/01) for scope of approval 4 .<br />
Refer to Ultrasecure SCD2 mesh security doorset (LPCB Ref. No.<br />
450j/02) for scope of approval 4 .<br />
1. The minimum height of <strong>part</strong>itioning systems incorporating doorsets is 1.08 m.<br />
2. The minimum width of walls incorporating doorsets is 0.63 m.<br />
3. The walling system can either be constructed as a straight walling system or incorporate 270 degree angles in the wall line. This<br />
angle is measured between the attack faces of the two adjacent panels.<br />
4. The doorsets are not designed to be fitted within the ceiling system.<br />
5. The <strong>part</strong>itioning system’s resistance relies on the supporting substrate offering compatible resistance to manual attack.<br />
6. The Ultrasecure security cage system is approved when installed in accordance with the instructions detailed on document SCS-<br />
DV-3-FIT-01 (Ref.B).<br />
The Expanded Metal Company Limited<br />
P.O.Box 14, Longhill Industrial Estate (North), Hartlepool TS25 1PR, United Kingdom<br />
Tel: +44 (0)1429 867 388 • Fax: +44 (0)1429 867 355<br />
E-mail: fencing@expamet.co.uk • Website: www.expandedmetalfencing.co.uk<br />
Certificate No: 731b to LPS 1175: Issue 7<br />
Secure Partition Wall Systems<br />
Product Name Type Minimum<br />
Wall<br />
Height<br />
(m)<br />
Securilath HD1<br />
Partition wall<br />
Standard<br />
system<br />
Securilath HD1-PB Partition wall<br />
system<br />
Securilath MD1<br />
Partition wall<br />
system<br />
Securilath HD1 Twin Partition wall<br />
system<br />
Maximum<br />
Wall<br />
Height<br />
(m)<br />
Minimum<br />
Wall<br />
Width<br />
(m)<br />
Maximum<br />
Wall<br />
Width<br />
(m)<br />
Security<br />
Rating 2<br />
Cert.<br />
No.<br />
1.2 3.0 0.6 N/A 1 2 731b/01<br />
1.2 3.0 0.6 N/A 1 1 731b/02<br />
1.2 3.0 0.6 N/A 1 1 731b/03<br />
1.2 3.0 0.6 N/A 1 3 731b/04<br />
Approved Configurations<br />
20 Nov 2011 469
PART 4: SECTION 7<br />
SECURE WALLING SYSTEMS<br />
System Layers Configuration Approved Installation<br />
Instructions<br />
Securilath<br />
HD1 Standard<br />
Attack face 19 mm thick plyw ood fixed using 4.5 mm by 50 mm<br />
w oodscrew s at 300 mm centres.<br />
‘HD1 Securilath’ mesh panels fixed to timber studs using<br />
65 mm by 3.35 mm bright annular nails to BS1202 w ith R36<br />
w ashers at maximum 400 mm centres.<br />
Securilath<br />
HD1-PB<br />
Securilath<br />
MD1<br />
Securilath<br />
HD1 Tw in<br />
Timber stud<br />
Non- Attack<br />
face<br />
Attack face<br />
Timber stud<br />
Non- Attack<br />
face<br />
Attack face<br />
Timber stud<br />
Non- Attack<br />
face<br />
Attack face<br />
Timber stud<br />
Non- Attack<br />
face<br />
75 mm by 50 mm softw ood frame w ith vertical studs at<br />
600 mm centres. Noggins shall be at maximum 400 mm<br />
centres. Timber fixed w ith M8 by 80 mm screw s.<br />
12 mm thick plasterboard fixed using bugle head dryw all<br />
screw fixings PN2 3.5 mm by 55 mm BZP at maximum 450<br />
mm centres.<br />
12 mm thick plasterboard fixed using bugle head dryw all<br />
screw fixings PN2 3.5 mm by 55 mm BZP at maximum 450<br />
mm centres.<br />
‘HD1 Securilath’ mesh panels fixed to timber studs using<br />
65 mm by 3.35 mm bright annular nails to BS1202 w ith R36<br />
w ashers at maximum 400 mm centres.<br />
75 mm by 50 mm softw ood frame w ith vertical studs at<br />
600 mm centres. Noggins shall be at maximum 400 mm<br />
centres. Timber fixed w ith M8 by 80 mm screw s.<br />
12 mm thick plasterboard fixed using bugle head dryw all<br />
screw fixings PN2 3.5 mm by 55 mm BZP at maximum 450<br />
mm centres.<br />
19 mm thick plyw ood fixed using 4.5 mm by 50 mm<br />
w oodscrew s at 300 mm centres.<br />
‘MD1 Securilath’ mesh panels fixed to timber studs using<br />
65 mm by 3.35 mm bright annular nails to BS1202 w ith R36<br />
w ashers at maximum 400 mm centres.<br />
75 mm by 50 mm softw ood frame w ith vertical studs at<br />
600 mm centres. Noggins shall be at maximum 400 mm<br />
centres. Timber fixed w ith M8 by 80 mm screw s.<br />
12 mm thick plasterboard fixed using bugle head dryw all<br />
screw fixings PN2 3.5 mm by 55 mm BZP at maximum 450<br />
mm centres.<br />
19 mm thick plyw ood fixed using 4.5 mm by 50 mm<br />
w oodscrew s at 300 mm centres.<br />
‘HD1 Securilath’ mesh panels fixed to timber studs using<br />
65 mm by 3.35 mm bright annular nails to BS1202 w ith R36<br />
w ashers at maximum 400 mm centres.<br />
75 mm by 50 mm softw ood frame w ith vertical studs at<br />
600 mm centres. Noggins shall be at maximum 400 mm<br />
centres. Timber fixed w ith M8 by 80 mm screw s.<br />
‘HD1 Securilath’ mesh panels fixed to timber studs using<br />
65 mm by 3.35 mm bright annular nails to BS1202 w ith R36<br />
w ashers at maximum 400 mm centres.<br />
19 mm thick plyw ood fixed using 4.5 mm by 50 mm<br />
w oodscrew s at 300 mm centres.<br />
Securilath Installation Guide<br />
IP90 LPCB Inst. Issue 6, April<br />
2011<br />
Securilath Installation Guide<br />
IP90 LPCB Inst. Issue 6, April<br />
2011<br />
Securilath Installation Guide<br />
IP90 LPCB Inst. Issue 6, April<br />
2011<br />
Securilath Installation Guide<br />
IP90 LPCB Inst. Issue 6, April<br />
2011<br />
Notes:<br />
1. There is no restriction on the maximum width as long as the <strong>part</strong>ition wall is constructed in a straight run and does not include any<br />
corners.<br />
2. These systems are approved as plain <strong>part</strong>itions. Please refer to the introduction to the <strong>section</strong> on secure walling systems in Red Book<br />
Volume 2 for further information.<br />
470 20 Nov 2011
PART 4: SECTION 8<br />
SECURE ROOFING SYSTEMS<br />
Roofing systems listed in this <strong>section</strong> are approved to LPS 1175 Requirements and testing procedures for the<br />
LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and<br />
free-standing barriers.<br />
In order to comply with the terms of the approval, the roofing systems should be designed and installed in<br />
accordance with the relevant system manuals noted within the product entry. The styles of tile/panel included<br />
within the scope of approval, the range of roof pitches to which they can be fitted and the accessories that are<br />
covered by the scope of approval are also noted in each product entry.<br />
Icopal S. A.<br />
Parc Industriel des Hauts Sarts, Rue de Hermee 186, Herstal, Belgium<br />
Tel: +32 4240 5151 • Fax: +32 4240 5199<br />
E-mail: sales@decra.co.uk • Website: www.decra.co.uk<br />
UK sales, marketing, distribution and technical enquiries:<br />
Decra Roofing Systems Limited, Unit 4, Crompton Fields, Crompton Way, Crawley, West Sussex RH10 9QB,<br />
United Kingdom<br />
Tel: +44 (0)1293 545058 • Fax: +44 (0)1293 562709<br />
E-mail: sales@decra.co.uk • Website: www.decra.co.uk<br />
Certificate No: 834a to LPS 1175: Issue 5.3<br />
Security Roof Tiling Systems<br />
Product Name<br />
Overall Tile<br />
Tile Cover<br />
Security<br />
Cert. No.<br />
Size (mm)<br />
(mm)<br />
Rating<br />
Decra Classic 1324 x 410 1260 x 370 1 834a/01<br />
Decra Stratos 1290 x 360 1230 x 320 1 834a/02<br />
Decra Elegance 1324 x 410 1260 x 370 1 834a/03<br />
Decra Plus 1324 x 410 1260 x 368 1 834a/04<br />
Approved Configurations<br />
System Roof pitch Tile bond<br />
configurations<br />
Batten size to be used according to the maximum rafter<br />
spacing (mm)<br />
Staggered Straight 450 600 900 1200 1500<br />
Decra 10° to 90° 38 x 25 50 x 25 50 x 50 50 x 50 50 x 65<br />
Classic<br />
Decra 10° to 90° - 38 x 38 50 x 38 50 x 50 50 x 50 50 x 65<br />
Stratos<br />
Decra 10° to 90° 38 x 25 50 x 25 50 x 50 50 x 50 50 x 65<br />
Elegance<br />
Decra Plus 10° to 90° 38 x 25 50 x 25 50 x 50 50 x 50 50 x 65<br />
Approved Accessories<br />
20 Nov 2011 471
PART 4: SECTION 8<br />
SECURE ROOFING SYSTEMS<br />
Accessory Decra Classic Decra Elegance Decra Stratos Decra Plus<br />
Cloaked verge cap – Left hand DH_B2 EH_B2 - -<br />
Cloaked verge cap – Right hand DI_B2 EI_B2 - -<br />
Barge cover – Left hand DH_B1 - SH_B1 -<br />
Barge cover – Right hand DI_B1 - SI_B1 -<br />
Barge cover eaves closure – Left DH_DE1 - SH_DE1 -<br />
hand<br />
Barge cover eaves closure – Right DI_DE1 - SI_DE1 -<br />
hand<br />
Top course DC_B1 EC_B1 DC_B1 DC_B1<br />
Decra Plus D box barge cap - - - PH_D1<br />
Decra Plus D ridge/hip sealing strip - - - PSXD1<br />
D ridge hip end closure unit DD_DH1 ED_DH1 DD_DH1 DD_DH1<br />
D ridge DD_B1 ED_B1 DD_B1 PD_D1<br />
D ridge end closure unit DD_DE1 ED_DE1 DD_DE1 DD_DE1<br />
In-line air vent DVA_W1 EVA_W1 SVA_W1 DVA_W1<br />
In-line soil/mech extract vent DVS_W1 EVS_W1 SVS_W1 DVS_W1<br />
Universal D ridge/hip ventilator DVUXW1 DVUXW1 DVUXW1 DVUXW1<br />
Decra Classic D ridge vent filler DVRXW1 DVRXW1 - -<br />
Finishing kit DU_B1 EU_B1 DU_B1 DU_B1<br />
Fixing nails (6kg) pack DNXB5 DNXB5 DNXB5 DNXB5<br />
Decra power tile fixing nails DNXP7 DNXP7 DNXP7 -<br />
Approved System Instructions<br />
This approval covers the above roof tiling systems when designed and installed in accordance with the following instructions.<br />
System Instructions<br />
Decra Classic Decra Classic tile Secured by Design instructions (October 2007)<br />
Decra Stratos Decra Stratos tile Secured by Design instructions (October 2007)<br />
Decra Elegance Decra Elegance tile Secured by Design instructions (October 2007)<br />
Decra Plus Decra Plus tile Secured by Design instructions (October 2007)<br />
Notes<br />
1. This approval assumes the roofing systems are installed to roof structures of equivalent resistance to attack.<br />
2. This approval covers the roofing systems when installed in the ‘unsupported underlay’ configuration.<br />
472 20 Nov 2011
PART 4: SECTION 9<br />
PERIMETER SECURITY PRODUCTS<br />
This <strong>section</strong> lists perimeter security products; such as fences, gates and turnstiles; that have been approved<br />
to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant<br />
building components, strongpoints, security enclosures and free-standing barriers.<br />
While previous versions of the standard specified six levels of resistance (security ratings), the latest version<br />
(Issue 6 and 7) specifies eight security ratings. The levels of risk on which the security ratings are based in<br />
Issue 6 and 7 are represented in the following chart.<br />
HIGH RISK<br />
LPS 1175 SR 8<br />
LPS 1175 SR 7<br />
LPS 1175 SR 6<br />
LPS 1175 SR 5<br />
LPS 1175 SR 4<br />
LPS 1175 SR 3<br />
LPS 1175 SR 2<br />
LOW RISK LPS 1175 SR 1<br />
Products certified to this standard provide 20 minutes of<br />
resistance to extreme means of attempting forced entry into<br />
higher value storage areas.<br />
Products certified to these standards provide 10 minutes of<br />
resistance to professional means of attempting forced entry into<br />
higher value storage areas using a wide range of tools including<br />
mains powered tools.<br />
Products certified to these standards resist experienced<br />
attempts at forced entry using a wide range of tools including<br />
battery powered tools lasting up to 10 minutes (SR 4 and 5) or<br />
5 minutes (SR 3).<br />
Products certified to this standard provide 3 minutes of<br />
resistance to determined attack by an opportunist burglar using<br />
a range of techniques including those that involve creation of<br />
noise.<br />
Products certified to this standard provide 1 minute of<br />
resistance to opportunist attempts at entry using a range of<br />
techniques including those that create noise such as those<br />
involving breaking glass.<br />
LPS 1175 supports the assessment, approval and specification of perimeter security products such as walls,<br />
fences, gates and turnstiles.<br />
Unlike current British and European fence standards, LPS 1175 is based on manual attack testing with the<br />
resistance provided by the products measured in terms of the attack tools and time available to the attacker. It<br />
enables specifiers to select products according to their performance relative to the risks faced rather than<br />
simply specifying them by design.<br />
Although the standard includes minimum requirements relating to the height of the product, the product’s<br />
resistance to scaling is not covered by the standard, nor is its resistance to tunnelling or vehicle impact.<br />
Further information on the security rating system and attack tools can be found in the standard itself, which<br />
can be downloaded from the Red Book web site www.<strong>RedBookLive</strong>.com.<br />
For details of products offering resistance to vehicle impact, please refer to Section 2.10.<br />
Product Selection<br />
When selecting a perimeter security product, it is important to note aspects such as the size, locking systems<br />
and directions of opening; all can affect the level of security provided by the product. These aspects of each<br />
certified product have therefore been described to enable selection of the most appropriate product.<br />
It is important to ensure that the products are installed in accordance with the manufacturer’s instructions and<br />
that all exposed fixings, the substrate into which the device is fitted and the locking mechanisms are regularly<br />
checked to ensure that they are in good condition and that they have not been tampered with.<br />
20 Nov 2011 473
PART 4: SECTION 9<br />
PERIMETER SECURITY PRODUCTS<br />
Unless otherwise stated, the security ratings attributed to the products listed require all locks to be fully<br />
engaged.<br />
474 20 Nov 2011
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
CLD Fencing Systems<br />
Unit 11, Springvale Business Centre, Millbuck Way, Sandbach, Cheshire CW11 3HY, United Kingdom<br />
Tel: +44 (0)1270 764751 • Fax: +44 (0)1270 757503<br />
E-mail: info@cld-fencing.com • Website: www.cld-fencing.com<br />
Certificate No: 999a to LPS 1175: Issue 7<br />
Security Fencing Systems<br />
Product<br />
Type<br />
Name<br />
Securus<br />
SR1<br />
Securus<br />
SR2<br />
Nominal<br />
Height (m)<br />
Maximum<br />
Post<br />
Centres (m)<br />
Gradients<br />
Angles in<br />
Fence Line<br />
Welded mesh security<br />
fencing system 1 2.4 2.515 0°, 9.5° and<br />
18.4° 4 100° to<br />
170°, 180°,<br />
190° to<br />
260°, 270°<br />
Vertical bar and mesh panel 2.4 2.515 0°, 9.5° and<br />
security fencing system 2 18.4°<br />
100° to<br />
170°, 180°,<br />
190° to<br />
260°, 270°<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1 999a/01<br />
2 999a/02<br />
Principle Components 5<br />
Component Type Description Securus Fencing System<br />
Base-plated<br />
posts<br />
Embedded<br />
posts<br />
Panels<br />
Clamping bars<br />
Reinforcing<br />
channels<br />
Base-Plated<br />
Version<br />
Primary posts Pow der coated steel posts. <br />
Embedded<br />
Version<br />
SR2<br />
Embedded<br />
Version<br />
Corner posts Pow der coated steel posts<br />
used to form angles in the<br />
fence line.<br />
100° to 170°<br />
190° to 260°<br />
270°<br />
Primary posts Pow der coated steel posts. <br />
Intermediate posts<br />
Corner posts<br />
Galvanised mesh<br />
panels<br />
Clamp bars<br />
Intermediate clamp<br />
bars<br />
Channel<br />
Approved Assembly and Installation Drawings<br />
Pow der coated steel<br />
intermediate posts.<br />
Pow der coated steel posts<br />
used to form angles in the<br />
fence line.<br />
‘Security 358’ w elded mesh<br />
panels.<br />
Clamping bars secured over<br />
the mesh to the attack face of<br />
each post.<br />
Clamping bars secured over<br />
the mesh to the attack face of<br />
each intermediate post.<br />
Channels secured over the<br />
mesh to reinforce it.<br />
100° to 170°<br />
190° to 260°<br />
270°<br />
<br />
100° to 170°<br />
190° to 260°<br />
270°<br />
One layer One layer Tw o layers<br />
<br />
SR1<br />
<br />
<br />
<br />
20 Nov 2011 475
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
Document Ref. Revision /<br />
Issue Date<br />
SR1/07/Bas<br />
(Draw ing 1 of 5)<br />
SR1/07/Bas<br />
(Draw ing 2 of 5)<br />
SR1/07/Bas<br />
(Draw ing 3 of 5)<br />
SR1/07/Bas<br />
(Draw ing 4 of 5)<br />
SR1/07/Bas<br />
(Draw ing 5 of 5)<br />
SR1/07/Fou<br />
(Draw ing 1 of 5)<br />
SR1/07/Fou<br />
(Draw ing 2 of 5)<br />
SR1/07/Fou<br />
(Draw ing 3 of 5)<br />
SR1/07/Fou<br />
(Draw ing 4 of 5)<br />
SR1/07/Fou<br />
(Draw ing 5 of 5)<br />
SR2/07/Fou<br />
(Draw ing 1 of 5)<br />
SR2/07/Fou<br />
(Draw ing 2 of 5)<br />
SR2/07/Fou<br />
(Draw ing 3 of 5)<br />
SR2/07/Fou<br />
(Draw ing 4 of 5)<br />
SR2/07/Fou<br />
(Draw ing 5 of 5)<br />
Revision 7<br />
12/01/11<br />
Revision 7<br />
12/01/11<br />
Revision 7<br />
12/01/11<br />
Revision 7<br />
12/01/11<br />
Revision 7<br />
12/01/11<br />
Revision 6<br />
06/12/10<br />
Revision 6<br />
06/12/10<br />
Revision 6<br />
06/12/10<br />
Revision 6<br />
06/12/10<br />
Revision 6<br />
06/12/10<br />
Revision 5<br />
13/12/10<br />
Revision 5<br />
13/12/10<br />
Revision 5<br />
13/12/10<br />
Revision 5<br />
13/12/10<br />
Revision 5<br />
13/12/10<br />
Title / Contents<br />
General assembly<br />
Elevations detail<br />
Installation instructions<br />
Component details<br />
Variable angle details<br />
General assembly<br />
Elevations detail<br />
Installation instructions<br />
Component details<br />
Variable angle details<br />
General assembly<br />
Elevations detail<br />
Installation instructions<br />
Component details<br />
Variable angle details<br />
Base-Plated<br />
Version<br />
<br />
<br />
<br />
<br />
<br />
Securus Fencing System<br />
SR1<br />
Embedded<br />
Version<br />
<br />
<br />
<br />
<br />
<br />
SR2<br />
Embedded<br />
Version<br />
<br />
<br />
<br />
<br />
<br />
Notes:<br />
1. The fencing system is available in configurations to suit either surface mounting onto hard surfaces 3 or embedding within concrete<br />
foundations placed in the ground 3 .<br />
2. The fencing system is available in configurations to suit embedding within concrete foundations placed within the ground 3 only.<br />
3. It is important to ensure that the local ground onto/into which the fence is installed offers compatible strength and that the fence is<br />
installed in accordance with the documents listed in the table entitled ‘Approved assembly and installation drawings’.<br />
4. The base-plated version of the ‘Securus SR1’ fencing system is not approved for use on 18.4° gradients.<br />
5. The fencing system should only be constructed using components supplied by CLD Fencing Systems.<br />
6. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two<br />
adjacent fence panels.<br />
H S Jackson & Son (Fencing) Limited, t/a Jacksons Fencing<br />
Stowting Common, Ashford, Kent TN25 6BN, United Kingdom<br />
Tel: +44 (0)1233 750393 • Fax: +44 (0)1233 750178<br />
E-mail: security@jacksons-fencing.co.uk • Website: www.jacksons-fencing.co.uk<br />
Certificate No: 913a to LPS 1175: Issue 6<br />
Security Fencing System<br />
Product<br />
Name<br />
Type Height (m) Post<br />
Centres (m)<br />
Gradients<br />
Jakoustic Timber security 2.5, 2.75, 3.0 0.125 to 2.4 0° to<br />
Class 3 fencing system 1 or 3.25<br />
18.5°<br />
Angles In<br />
Fence Line<br />
90°, 180° or<br />
270°<br />
Security Cert.<br />
Rating No.<br />
3 913a/01<br />
476 20 Nov 2011
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
Principle Components 1<br />
Component Type Description<br />
Timber Boards Timber acoustic boards – Mid <strong>section</strong> 142.75 mm by 34 mm by 4800 mm long timber<br />
tongue and groove board.<br />
Timber acoustic boards – Base<br />
<strong>section</strong><br />
142.75 mm by 34 mm by 4800 mm long timber<br />
tongued board.<br />
Timber acoustic boards – Top <strong>section</strong> 123 mm by 34 mm by 4800 mm long and /or 48<br />
mm by 34 mm by 4800 mm long timber grooved<br />
board.<br />
Posts<br />
Intermediate and corner posts 152 mm by 89 mm by 16 mm universal beam<br />
either 3350 mm, 3600 mm, 3850 mm or 4100<br />
mm long to suit fence height.<br />
Timber batten for steel post<br />
100 mm by 50 mm timber batten either 2700 mm,<br />
2950 mm, 3200 mm or 3450 mm long to suit post<br />
height.<br />
Capping Rail Timber capping rail 145 mm by 34 mm by 4800 mm long timber<br />
<strong>section</strong>.<br />
Counter Rail Timber counter rail 70 mm by 34 mm by 2400 mm long timber<br />
<strong>section</strong>.<br />
Post Cover Boards Timber post cover board 125 mm by 34 mm by 3200 mm long timber<br />
board.<br />
Corner Supports Timber corner support 54 mm by 45 mm by 3200 mm long timber<br />
<strong>section</strong>.<br />
Timberlok Screws Steel screws 100 mm and 150 mm long galvanised steel<br />
screw.<br />
2, 3, 4<br />
Approved Assembly and Installation Drawings<br />
Document Ref. Revision / Issue Date Title / Contents<br />
09 HS1/1001 (Sheet 1 of 3) 0.1 05/01/10 Jakoustic Class 3 fencing general detail<br />
09 HS1/1001 (Sheet 2 of 3) 0.1 05/01/10 Jakoustic Class 3 fencing general detail<br />
09 HS1/1001 (Sheet 3 of 3) 0.1 05/01/10 Jakoustic Class 3 fencing raking detail<br />
Notes<br />
1. The fencing system should only be constructed using components supplied by Jacksons Fencing.<br />
2. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength and that the fence is<br />
installed in accordance with the documents listed the table entitled ‘Approved assembly and installation drawings’.<br />
3. The fencing system is approved for installation onto/into flat ground of gradients between 0° and 18.5°.<br />
4. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two<br />
adjacent fence posts.<br />
Certificate No: 913b to LPS 1175: Issue 6<br />
Security Fencing Systems<br />
Product<br />
Name<br />
Type<br />
Height<br />
(m)<br />
Post<br />
Centres<br />
(m)<br />
Trident 4 Vertical bar and mesh panel security 3.6 0.260 to<br />
fencing system 1 2.57<br />
Trident 5 Vertical bar and mesh panel security 4.2 0.260 to<br />
fencing system 1 2.57<br />
Gradients<br />
Angles in<br />
Fence Line<br />
0° to 5.7° 90°, 180° or<br />
270°<br />
0° to 5.7° 90°, 180° or<br />
270°<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
4 913b/01<br />
5 913b/02<br />
Principle Components 1<br />
20 Nov 2011 477
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
Component Type Description<br />
Panels Galvanised vertical bar and mesh<br />
panels<br />
Fence panels comprising of reinforced 3/8” tubular vertical bars<br />
welded within 60 mm by 40 mm horizontal rails. The panels<br />
incorporate ‘358’ mesh panels welded on either face.<br />
Posts Galvanised steel posts 120 mm by 120 mm by 5 mm galvanised steel post.<br />
Toppings Concertina barbed tape topping 800 mm diameter barbed tape topping<br />
Document Ref.<br />
Approved Assembly and Installation Drawings 2, 3, 4 Trident 4 Trident 5<br />
Revision / Issue<br />
Date<br />
Title / Contents<br />
Product Name<br />
09 HS1_1002<br />
(Sheet 1 of 5)<br />
09 HS1_1002<br />
(Sheet 2 of 5)<br />
09 HS1_1002<br />
(Sheet 3 of 5)<br />
09 HS1_1002<br />
(Sheet 4 of 5)<br />
09 HS1_1002<br />
(Sheet 5 of 5)<br />
Revision 0.2<br />
30/03/10<br />
Revision 0.2<br />
30/03/10<br />
Revision 0.2<br />
30/03/10<br />
Revision 0.2<br />
30/03/10<br />
Revision 0.2<br />
30/03/10<br />
09 HS1_1003<br />
(Sheet 1 of 5)<br />
Revision 0<br />
31/03/10<br />
09 HS1_1003 Revision 0<br />
(Sheet 2 of 5) 31/03/10<br />
09 HS1_1003 Revision 0<br />
(Sheet 3 of 5) 31/03/10<br />
09 HS1_1003 Revision 0<br />
(Sheet 4 of 5) 31/03/10<br />
09 HS1_1003 Revision 0<br />
(Sheet 5 of 5) 31/03/10<br />
HS1_4001 Revision 0.0<br />
31/03/2010<br />
3.6 m high Trident 4 fencing general layout <br />
3.6m Trident 4 <strong>section</strong>s, details and notes <br />
3.6m high Trident 4 fencing stepped using standard <br />
components<br />
3.6m high Trident 4 fencing stepped using double <br />
posts<br />
3.6m high Trident 4 fencing stepped using special <br />
stepped posts<br />
4.2 m high Trident 5 fencing general layout <br />
4.2 m Trident 5 <strong>section</strong>s, details and notes <br />
4.2 m high Trident 5 fencing stepped using<br />
standard components<br />
4.2m high Trident 5 fencing stepped using double<br />
posts<br />
4.2m high Trident 5 fencing stepped using special<br />
stepped posts<br />
Concertina barbed tape topping option for trident<br />
fencing range<br />
<br />
<br />
<br />
<br />
<br />
Notes<br />
1. The fencing system should only be constructed using components supplied by Jacksons Fencing.<br />
2. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength and that the fence is<br />
installed in accordance with the documents listed the table entitled ‘Approved assembly and installation drawings’.<br />
3. The fencing system is approved for installation onto/into flat ground of gradients between 0° and 5.7°.<br />
4. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two<br />
adjacent fence posts.<br />
Heras U.K. Fencing Systems<br />
Herons Way, Balby, Doncaster DN4 8WA, United Kingdom<br />
Tel: +44 (0)1302 364551 • Fax: +44 (0)1302 322401<br />
E-mail: enquiries@herasuk.co.uk • Website: www.heras.co.uk<br />
Certificate No: 890a to LPS 1175: Issue 6<br />
Security Fencing Systems<br />
Product Name Type Height (m) Post<br />
Centres<br />
(m)<br />
Contour Standard<br />
Capped<br />
Gradients<br />
Angles In<br />
Fence Line 1<br />
Railings 1.8, 2.0 and 2.4 2.84 16.5° 3 75° to 105°,<br />
165° to 195°<br />
and<br />
255° to 265°<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1 890a/01<br />
478 20 Nov 2011
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
Product Name Type Height (m) Post<br />
Centres<br />
(m)<br />
Contour Mitred<br />
Top<br />
Contour Security<br />
Capped<br />
Contour Security<br />
Mitred Top<br />
Contour Fullered<br />
Top<br />
Gradients<br />
Angles In<br />
Fence Line 1<br />
Railings 1.8, 2.0 and 2.4 2.84 1.65° 3 75° to 105°,<br />
165° to 195°<br />
and<br />
255° to 265°<br />
Railings 1.8, 2.0 and 2.4 2.755 17° 3 75° to 105°,<br />
165° to 195°<br />
and<br />
255° to 265°<br />
Railings 1.8, 2.0 and 2.4 2.755 17° 3 75° to 105°,<br />
165° to 195°<br />
and<br />
255° to 265°<br />
Railings 1.8, 2.0 and 2.4 2.84 16.5° 3 75° to 105°,<br />
165° to 195°<br />
and<br />
255° to 265°<br />
Contour Point Top Railings 1.8, 2.0 and 2.4 2.84 16.5° 3 75° to 105°,<br />
165° to 195°<br />
and<br />
255° to 265°<br />
Contour Square<br />
Bar Capped Top<br />
Pallas Xtra<br />
Zenith<br />
Railings 1.8, 2.0 and 2.4 2.84 16.5° 3 75° to 105°,<br />
165° to 195°<br />
and<br />
255° to 265°<br />
Welded mesh<br />
security fencing<br />
system<br />
Welded mesh<br />
security fencing<br />
system<br />
1.8, 2.0 and 2.4 2.53 0° 2 175° to 185°<br />
and<br />
265° to 275°<br />
1.8, 2.0, 2.4,<br />
3.0, 4.2 and 5.2<br />
2.44 0° 2 175° to 185°<br />
and<br />
265° to 275°<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
1 890a/02<br />
1 890a/03<br />
1 890a/04<br />
1 890a/05<br />
1 890a/06<br />
1<br />
1 890a/08<br />
1 890a/09<br />
Principle Components (Contour Fencing Systems) 4<br />
Component Type Description<br />
Contour<br />
Standard<br />
Capped<br />
Finials<br />
Fishplates<br />
Contour<br />
Mitred<br />
Top<br />
Fencing System<br />
Contour<br />
Security<br />
Mitred<br />
Top<br />
Contour<br />
Security<br />
Capped<br />
Contour<br />
Fullered<br />
Top<br />
Contour<br />
Point<br />
Top<br />
Fullered Fullered finial <br />
Point Point top finial <br />
Intermediate<br />
fishplate<br />
Corner<br />
fishplate<br />
Square<br />
Bar<br />
Capped<br />
Top<br />
Fishplate used<br />
to attach rails to<br />
intermediate<br />
posts. These<br />
form angles in<br />
the fence<br />
between 165°<br />
and 195° 1 <br />
Fishplate used <br />
and 265° 1<br />
to attach rails to<br />
intermediate<br />
posts. These<br />
form angles in<br />
the fence<br />
between 75°<br />
and 105° and<br />
between 255°<br />
20 Nov 2011 479
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
Pales<br />
Posts<br />
Rails<br />
Standard<br />
capped<br />
pales<br />
Standard<br />
mitred pales<br />
25.5 mm (outer<br />
diameter) steel<br />
tubes at<br />
0.125 mm<br />
centres<br />
25.5 mm (outer<br />
diameter) steel<br />
tubes at<br />
0.125 mm<br />
centres<br />
TR300 pales 25.5 mm (outer<br />
diameter) steel<br />
tubes at<br />
0.125 mm<br />
centres<br />
Security<br />
capped<br />
pales<br />
Security<br />
mitred pales<br />
Square bar<br />
capped<br />
pales<br />
HD rolled<br />
formed<br />
posts<br />
HD1 rails<br />
HD2 rails<br />
HD3 rails<br />
25.5 mm (outer<br />
diameter) steel<br />
tubes at<br />
0.103 mm<br />
centres<br />
25.5 mm (outer<br />
diameter) steel<br />
tubes at<br />
0.103 mm<br />
centres<br />
25 mm by<br />
25 mm steel<br />
tubes at<br />
0.125 mm<br />
centres<br />
HD rolled<br />
formed post of<br />
nominal cross<br />
<strong>section</strong> 117 mm<br />
by 43.5 mm<br />
55 mm by<br />
52 mm by<br />
1.5 mm rail<br />
55 mm by<br />
52 mm by<br />
1.5 mm rail<br />
55 mm by<br />
52 mm by<br />
1.5 mm rail<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Principle Components (Pallas Xtra and Zenith Fencing Systems) 4<br />
Component Type Description Fencing<br />
Pallas System Zenith<br />
Xtra<br />
Panels Pallas Xtra welded<br />
mesh panels<br />
Welded mesh formed from nominal 6 mm diameter steel<br />
vertical wires at 50 mm centres and pairs of 8 mm diameter<br />
horizontal wires at 200 mm centres<br />
<br />
Zenith welded mesh<br />
panels<br />
Welded mesh formed from nominal 4 mm diameter steel<br />
wires at 76.3 mm (3 inch) vertical centres and 12.7 mm (1/2<br />
inch) horizontal centres<br />
<br />
480 20 Nov 2011
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
Panel clamp<br />
bars<br />
Posts<br />
Hexafix clamp bars<br />
Zenith clamp bars<br />
Hexafix RHS<br />
intermediate posts<br />
Hexafix RHS corner<br />
posts<br />
Zenith intermediate<br />
posts<br />
Zenith intermediate<br />
posts<br />
Zenith intermediate<br />
posts<br />
Zenith intermediate<br />
posts<br />
Zenith corner posts<br />
Zenith corner posts<br />
Zenith corner posts<br />
40 mm by 5 mm slotted steel clamp bars secured using M8<br />
by 40 mm shear drive bolts<br />
40 mm by 5 mm slotted steel clamp bars secured using M8<br />
cup square bolts and shear nuts<br />
60 by 40 mm by 3 mm RHS posts with integral panel<br />
mounting clips<br />
60 by 60 mm by 2 mm SHS posts with integral panel<br />
mounting clips<br />
60 by 60 mm by 2 mm SHS posts for use on 1.8 m, 2.0 m<br />
and 2.4 m high fences<br />
80 by 40 mm by 3 mm RHS posts for use on 3.0 m high<br />
fences<br />
80 by 80 mm by 3 mm RHS posts for use on 4.2 m high<br />
fences<br />
100 by 100 mm by 4 mm SHS posts for use on 5.2 m high<br />
fences<br />
60 by 60 mm by 2 mm SHS posts for use on 1.8 m, 2.0 m<br />
and 2.4 m high fences<br />
80 by 80 mm by 3 mm RHS posts for use on 3.0 m and 4.2 m<br />
high fences<br />
100 by 100 mm by 4 mm SHS posts for use on 5.2 m high<br />
fences<br />
U clamp sets U- clamp set Three U-clamp sets comprising 5 mm diameter steel U-<br />
clamps, plastic bases, steel retaining plates, M6 shear nuts<br />
and plastic covers<br />
Approved Assembly and Installation Drawings (Contour, Pallas Xtra and Zenith Fencing Systems) 5<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Document<br />
Ref.<br />
Form 39 0<br />
7/7/10<br />
Form 40 0<br />
11/11/10<br />
Form 42<br />
(Contour<br />
Capped/<br />
Mitred/<br />
Square Bar)<br />
Form 42<br />
(Contour<br />
Finial Top)<br />
Form 42<br />
(Contour<br />
Security<br />
Capped/<br />
Mitred Top)<br />
Revision /<br />
Issue Date<br />
Title / Contents<br />
Customer information<br />
(Zenith)<br />
Customer information<br />
(Pallas Xtra)<br />
11/11/10 Customer information<br />
(Contour Capped /<br />
Mitred / Square Bar)<br />
11/11/10 Customer information<br />
(Contour Point Top /<br />
Fullered Top)<br />
11/11/10 Customer information<br />
(Contour Capped /<br />
Mitred / Square Bar)<br />
Pallas<br />
Xtra<br />
<br />
Zenith<br />
<br />
Fencing System<br />
Contour<br />
Standard<br />
Capped<br />
and<br />
Contour<br />
Mitred<br />
Top<br />
<br />
Contour<br />
Security<br />
Capped<br />
and<br />
Contour<br />
Security<br />
Mitred<br />
Top<br />
<br />
Contour<br />
Point Top<br />
and<br />
Contour<br />
Fullered<br />
Top<br />
<br />
Square<br />
Bar<br />
Capped<br />
Top<br />
<br />
20 Nov 2011 481
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
ref_pal_1<br />
B<br />
11/11/10<br />
Pallas Xtra<br />
specification 1.8m,<br />
2.0m, 2.4m high fence<br />
installation details<br />
<br />
ref_pal_3 0<br />
19/3/09<br />
ref_zen_1<br />
A<br />
11/11/10<br />
ref_zen_3 0<br />
16/3/09<br />
Hexafix system<br />
External corner<br />
assembly<br />
Zenith system<br />
specification<br />
All heights<br />
Installation details<br />
Zenith system in<br />
ground spec corner<br />
arrangement<br />
<br />
<br />
<br />
Notes<br />
1. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two<br />
adjacent fence posts.<br />
2. The fencing system is only approved for installation into flat level ground.<br />
3. The gradient is based on a maximum rake of 800 mm along the length of the rail. It relates to the 2.0 m and 2.4 m high fences. The<br />
scope of approval for the 1.8 m high fences only covers fences installed on flat level ground.<br />
4. The fencing system should only be constructed using components supplied by Heras U.K. Fencing Systems.<br />
5. The fencing system is approved for installation into foundations buried in the ground, as detailed on the documents listed in the<br />
table above entitled ‘Approved Assembly and Installation Drawings’. The approval does not cover the use of base plated posts<br />
surface mounted on top of the ground.<br />
6. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength.<br />
NK Fencing Limited<br />
40 Trailcock Road, Carrickfergus, Co. Antrim, Northern Ireland BT38 7NU, United Kingdom<br />
Tel: +44 (0)28 9335 1172 • Fax: +44 (0)28 9336 4336<br />
E-mail: mail@nkfencing.com • Website: www.nkfencing.com<br />
Certificate No: 951a to LPS 1175: Issue 6<br />
Security Fencing Systems<br />
Product<br />
Type<br />
Name<br />
Ibex Hi Welded mesh security<br />
Security fencing system<br />
Height<br />
(m)<br />
Post Centres<br />
(m)<br />
Gradients<br />
1.8 to 3 1 to 2.46 0° to<br />
5.71°<br />
Angles in Security Cert.<br />
Fence Line Rating No.<br />
90° to 315° 1 951a/01<br />
Principal Components<br />
Component Type Description Ibex Hi Security Fencing<br />
System<br />
Panels<br />
Pre-galvanized welded<br />
mesh panels<br />
Galvanized welded mesh formed<br />
from nominal 4 mm diameter steel<br />
vertical and horizontal wires at<br />
76.2 mm and 12.7 mm centres<br />
respectively<br />
Base-plated<br />
version<br />
<br />
Standard<br />
(Embedded<br />
version)<br />
<br />
482 20 Nov 2011
Base-plated Posts NK Ibex Hi-Security<br />
standard post<br />
assembly<br />
NK Ibex Hi-Security<br />
end post assembly<br />
NK Ibex Hi-Security<br />
alternative end post<br />
assembly<br />
Hot dip galvanized steel<br />
intermediate post<br />
Hot dip galvanized steel post<br />
Hot dip galvanized steel post used<br />
to form the end of the fence line or<br />
used in pairs to form acute and<br />
obtuse angles in the fence line<br />
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
180°<br />
<br />
>90° to 180° to 270° to 315°<br />
Embedded Posts<br />
NK Ibex Hi-Security<br />
corner post assembly<br />
NK Ibex Hi-Security<br />
standard post<br />
assembly<br />
NK Ibex Hi-Security<br />
end post assembly<br />
Hot dip galvanized steel post used<br />
to form right angles in the fence<br />
line<br />
Hot dip galvanized steel<br />
intermediate post<br />
Hot dip galvanized steel post used<br />
to form the end of the fence line or<br />
used in pairs to form acute and<br />
obtuse angles in the fence line<br />
270°<br />
180°<br />
>90° to 180° to 270° to 315°<br />
Panel clamping<br />
bars<br />
NK Ibex Hi-Security<br />
corner post assembly<br />
Stretcher bar<br />
Hot dip galvanized steel post used<br />
to form right angles in the fence<br />
line<br />
Clamping bars secured to the<br />
attack face of each post<br />
<br />
270°<br />
<br />
Approved Assembly and Installation Drawings<br />
Drawing No.<br />
/ Sheet<br />
1096M (Sheet<br />
22)<br />
1096M (Sheet<br />
23)<br />
1096M (Sheet<br />
24)<br />
1096M (Sheet<br />
25)<br />
1096M (Sheet<br />
26)<br />
1096M (Sheet<br />
27)<br />
1096M (Sheet<br />
28)<br />
Revision /<br />
Issue Date<br />
Title / Contents<br />
18/08/09 1.8-3.0 Ibex security fence (base plated<br />
posts) - Fence general arrangement<br />
Rev A 1.8-3.0 Ibex security fence (base plated<br />
02/09/09 posts) - Fence general arrangement for<br />
sloping ground (Option A - Panels above<br />
ground level)<br />
18/08/09 1.8-3.0 Ibex security fence (base plated<br />
posts) - Fence general arrangement for<br />
sloping ground (Option B - Buried panel<br />
bases)<br />
Rev B<br />
08/09/09<br />
1.8-3.0 Ibex security fence (base plated<br />
posts) - Fence erection details (Exploded<br />
views and <strong>section</strong>s at posts)<br />
18/08/09 1.8-3.0 Ibex security fence (base plated<br />
posts) - Fence erection details (Plan views)<br />
18/08/09 1.8-3.0 Ibex security fence (base plated<br />
posts) - Panel detail<br />
Rev A 1.8-3.0 Ibex security fence (base plated<br />
08/09/09 posts) - Post and stretcher bar detail<br />
Ibex Hi Security Fencing<br />
System<br />
Base-plated<br />
version<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Standard<br />
(Embedded<br />
version)<br />
20 Nov 2011 483
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
1096M (Sheet<br />
29)<br />
1096M (Sheet<br />
30)<br />
1096M (Sheet<br />
31)<br />
1096M (Sheet<br />
32)<br />
1096M (Sheet<br />
33)<br />
1096M (Sheet<br />
34)<br />
1096M (Sheet<br />
35)<br />
Notes<br />
18/08/09 1.8-3.0 Ibex security fence (buried posts) -<br />
Fence general arrangement<br />
Rev A 1.8-3.0 Ibex security fence (buried posts) -<br />
02/09/09 Fence general arrangement for sloping<br />
ground (Option A - Panels above ground<br />
level)<br />
18/08/09 1.8-3.0 Ibex security fence (buried posts) -<br />
Fence general arrangement for sloping<br />
ground (Option B - Buried panel bases)<br />
Rev B<br />
08/09/09<br />
1.8-3.0 Ibex security fence (buried posts) -<br />
Fence erection details (Exploded views and<br />
<strong>section</strong>s at posts)<br />
18/08/09 1.8-3.0 Ibex security fence (buried posts) -<br />
Fence erection details (Plan views)<br />
18/08/09 1.8-3.0 Ibex security fence (buried plated<br />
posts) - Panel detail<br />
Rev A 1.8-3.0 Ibex security fence (buried posts) -<br />
02/09/09 Post and stretcher bar detail<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
1. The fencing system should only be constructed using components supplied by NK Fencing Limited.<br />
2. The fencing system is available in configurations to suit either surface mounting onto hard surfaces or embedding within concrete<br />
foundations placed in the ground.<br />
3. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength and that the fence is<br />
installed in accordance with the documents listed in the table above entitled ‘Approved Assembly and Installation Drawings’.<br />
4. The fencing system is approved for installation onto/into flat ground of gradients between 0° and 5.71°.<br />
5. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two<br />
adjacent fence panels.<br />
TangoRail Limited<br />
Units 1-3,, Prothero Industrial Estate, Bilport Lane, Wednesbury, West Midlands WS10 0NT, United Kingdom<br />
Tel: +44 (0)844 8360008 • Fax: +44 (0)844 8360009<br />
E-mail: info@tangorail.com • Website: www.tangorail.com<br />
Certificate No: 942a to LPS 1175: Issue 6<br />
Security Fencing Systems<br />
Product Name Type Height (m) Post Centres<br />
(m)<br />
TangoRail<br />
TR100<br />
TangoRail<br />
TR200<br />
TangoRail<br />
TR150<br />
TangoRail<br />
TR250<br />
TangoRail<br />
TR300F<br />
TangoRail<br />
TR300P<br />
TangoRail<br />
TR400<br />
Railings<br />
Railings<br />
Railings<br />
Railings<br />
Railings<br />
Railings<br />
Railings<br />
1.8, 2.0, 2.1 and<br />
2.4<br />
1.8, 2.0, 2.1 and<br />
2.4<br />
1.8, 2.0, 2.1 and<br />
2.4<br />
1.8, 2.0, 2.1 and<br />
2.4<br />
1.8, 2.0, 2.1 and<br />
2.4<br />
1.8, 2.0, 2.1 and<br />
2.4<br />
1.8, 2.0, 2.1 and<br />
2.4<br />
Gradients 1 Angles In Fence<br />
Line 2<br />
2.84 16.5° 3 75° to 105°,<br />
165° to 195° and<br />
255° to 265°<br />
2.84 16.5° 3 75° to 105°,<br />
165° to 195° and<br />
255° to 265°<br />
2.755 17° 3 75° to 105°,<br />
165° to 195° and<br />
255° to 265°<br />
2.755 17° 3 75° to 105°,<br />
165° to 195° and<br />
255° to 265°<br />
2.84 16.5° 3 75° to 105°,<br />
165° to 195° and<br />
255° to 265°<br />
2.84 16.5° 3 75° to 105°,<br />
165° to 195° and<br />
255° to 265°<br />
2.84 16.5° 3 75° to 105°,<br />
165° to 195° and<br />
255° to 265°<br />
Security Cert.<br />
Rating No.<br />
1 942a/01<br />
1 942a/02<br />
1 942a/03<br />
1 942a/04<br />
1 942a/05<br />
1 942a/06<br />
1 942a/07<br />
484 20 Nov 2011
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
3<br />
Component Type Description TangoRail Fencing System<br />
Principle Components<br />
TR100 TR200 TR150 TR250 TR300F TR300P TR400<br />
Finials<br />
Fishplates<br />
Fullered Fullered finial <br />
Point Point top finial <br />
Intermediate<br />
fishplate<br />
Corner<br />
fishplate<br />
Fishplate<br />
used to attach<br />
rails to<br />
intermediate<br />
posts. These<br />
form angles in<br />
the fence<br />
between 165°<br />
and 195° 1 <br />
Fishplate <br />
and 265° 1<br />
used to attach<br />
rails to<br />
intermediate<br />
posts. These<br />
form angles in<br />
the fence<br />
between 75°<br />
and 105° and<br />
between 255°<br />
20 Nov 2011 485
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
Pales<br />
Posts<br />
Rails<br />
Standard<br />
capped<br />
pales<br />
Standard<br />
mitred pales<br />
25.5 mm<br />
(outer<br />
diameter)<br />
steel tubes at<br />
0.125 mm<br />
centres<br />
25.5 mm<br />
(outer<br />
diameter)<br />
steel tubes at<br />
0.125 mm<br />
centres<br />
TR300 pales 25.5 mm<br />
(outer<br />
diameter)<br />
steel tubes at<br />
0.125 mm<br />
centres<br />
Security<br />
capped<br />
pales<br />
Security<br />
mitred pales<br />
Square bar<br />
capped<br />
pales<br />
HD rolled<br />
formed posts<br />
HD1 rails<br />
HD2 rails<br />
HD3 rails<br />
25.5 mm<br />
(outer<br />
diameter)<br />
steel tubes at<br />
0.103 mm<br />
centres<br />
25.5 mm<br />
(outer<br />
diameter)<br />
steel tubes at<br />
0.103 mm<br />
centres<br />
25 mm by<br />
25 mm steel<br />
tubes at<br />
0.125 mm<br />
centres<br />
HD rolled<br />
formed post of<br />
nominal cross<br />
<strong>section</strong><br />
117 mm by<br />
43.5 mm<br />
55 mm by<br />
52 mm by<br />
1.5 mm rail<br />
55 mm by<br />
52 mm by<br />
1.5 mm rail<br />
55 mm by<br />
52 mm by<br />
1.5 mm rail<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Approved Assembly and Installation Drawings 4<br />
486 20 Nov 2011
Document<br />
Ref.<br />
Form 42<br />
(TangoRail<br />
TR100,<br />
TR200 and<br />
TR400)<br />
Form 42<br />
(TangoRail<br />
TR150 and<br />
TR250)<br />
Form 42<br />
(TangoRail<br />
TR300F and<br />
TR300P)<br />
Notes<br />
Revision /<br />
Issue Date<br />
Title / Contents<br />
11/11/10 Customer<br />
information<br />
(Contour<br />
Capped / Mitred /<br />
Square Bar)<br />
11/11/10 Customer<br />
information<br />
(Contour<br />
Capped / Mitred /<br />
Square Bar)<br />
11/11/10 Customer<br />
information<br />
(Contour<br />
Fullered Top /<br />
Point Top)<br />
TangoRail Fencing System<br />
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
TR100 TR200 TR150 TR250 TR300F TR300P TR400<br />
<br />
<br />
<br />
<br />
<br />
1. The gradient is based on a maximum rake of 800 mm along the length of the rail. It relates to the 2.0 m and 2.4 m high fences. The<br />
scope of approval for the 1.8 m high fences only covers fences installed on flat level ground.<br />
2. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two<br />
adjacent fence posts.<br />
3. The fencing system should only be constructed using components supplied by TangoRail Limited.<br />
4. The fencing system is approved for installation into foundations buried in the ground, as detailed on the documents listed in the<br />
table above entitled ‘Approved Assembly and Installation Drawings’. The approval does not cover the use of base plated posts<br />
surface mounted on top of the ground.<br />
5. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength.<br />
The Expanded Metal Company Limited<br />
P.O.Box 14, Longhill Industrial Estate (North), Hartlepool TS25 1PR, United Kingdom<br />
Tel: +44 (0)1429 867 388 • Fax: +44 (0)1429 867 355<br />
E-mail: fencing@expamet.co.uk • Website: www.expandedmetalfencing.co.uk<br />
Certificate No: 731c to LPS 1175: Issue 6<br />
Security Fencing Systems<br />
Product<br />
Type<br />
Name<br />
1576 Expanded metal mesh security fencing<br />
system<br />
Height Maximum Post Centres Security Cert.<br />
(m)<br />
(m)<br />
Rating No.<br />
2.4 3 2 731c/01<br />
Principal Components 1<br />
20 Nov 2011 487
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
Component Type Description<br />
Panels Expamet 1576 Expanded metal mesh panels<br />
Posts<br />
2.4 1576 Inter Post 3.215 m long intermediate post to suit 2.4 m<br />
high fence<br />
2.4 1576 Corner Post 3.215 m long corner post to suit 2.4 m high<br />
fence<br />
Stringers Diamond stringer Five stringers are located between each pair of<br />
adjacent posts on the non-attack side of the<br />
fence panel.<br />
Clamping Strips FCS 2440<br />
2.44 m long clamping strips secured to the<br />
attack face of each intermediate post.<br />
Corner clamp plate 2.44 m long ‘L’ <strong>section</strong> clamping plates secured<br />
to the attack face of each corner post.<br />
Notes<br />
1. The fencing system should be constructed using components supplied by The Expanded Metal Company Limited.<br />
2. The fencing system is approved for installation onto flat level ground of compatible strength in accordance with the instructions<br />
contained in document ‘1576/INST’ (Rev. D, 2/4/09).<br />
Certificate No: 731e to LPS 1175: Issue 7<br />
Security Fencing System<br />
Product<br />
Type<br />
Name<br />
1576 Class Twin-skinned expanded metal<br />
3<br />
mesh fencing system<br />
Height<br />
(m)<br />
Post<br />
Centres (m)<br />
Gradients 1 Angles in<br />
Fence Line 2<br />
2.465 0.5 to 3.0 0° 90°, 180° and<br />
270°<br />
Security Cert.<br />
Rating No.<br />
3 731e/01<br />
Principle Components 3<br />
Component Type Description<br />
Posts<br />
Intermediate posts (180°)<br />
Corner posts (90° and 270°)<br />
End posts<br />
80 mm by 40 mm by 3 mm galvanised steel posts.<br />
100 mm by 100 mm by 4 mm galvanised steel posts w ith 80 mm by 40 mm by<br />
3 mm RHS boxes running up adjacent sides.<br />
80 mm by 40 mm by 3 mm galvanised steel posts.<br />
Mid lugs<br />
35 mm high by 150 mm long by 5 mm thick galvanised steel flats for use on<br />
intermediate posts (six per post).<br />
End lugs<br />
35 mm high by 90 mm long by 5 mm thick galvanised steel flats for use on end<br />
posts and corner posts (six per post).<br />
Panels Galvanised mesh panels 1576 expanded metal mesh panels 3 .<br />
Horizontal rails Diamond stringer Six stringers are located betw een each pair of adjacent posts. These are<br />
sandw iched betw een the tw o mesh layers forming each fence panel.<br />
Clamping strips Flat clamp strip<br />
40 mm w ide by 5 mm thick by 2465 mm long galvanised steel bar.<br />
Corner clamp plate<br />
149 mm w ide by 2 mm thick by 2465 mm long ‘L’ shaped galvanised steel bar.<br />
Approved Assembly and Installation Drawings<br />
Document Reference Revision Title / Contents<br />
1576/C3/ILLUST<br />
1576/C3/INST<br />
D<br />
20/04/2011<br />
E<br />
20/04/2011<br />
1576 Fencing - Class 3<br />
1576 Class 3 Fencing Installation<br />
Notes:<br />
1. The fencing system is approved for installation into flat ground of gradients 0°.<br />
488 20 Nov 2011
PART 4: SECTION 9.1<br />
SECURITY FENCING<br />
2. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two<br />
adjacent fence panels.<br />
3. Mesh panels must be attached to the front and rear of the posts and stringers and overlap adjacent panels by at least 150 mm at<br />
intermediate posts.<br />
4. The fencing system should only be constructed using components supplied by The Expanded Metal Company Limited.<br />
5. The fencing system is only available for embedding into concrete foundations placed within the ground.<br />
6. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength and that the fence is<br />
installed in accordance with the documents listed in the table entitled ‘Approved Assembly and Installation Drawings’.<br />
20 Nov 2011 489
PART 4: SECTION 9.2<br />
SECURITY GATES<br />
CLD Fencing Systems<br />
Unit 11, Springvale Business Centre, Millbuck Way, Sandbach, Cheshire CW11 3HY, United Kingdom<br />
Tel: +44 (0)1270 764751 • Fax: +44 (0)1270 757503<br />
E-mail: info@cld-fencing.com • Website: www.cld-fencing.com<br />
Certificate No: 999b to LPS1175: Issue 7<br />
Security Gates<br />
Product<br />
Name<br />
Lockmaster<br />
Type<br />
Height<br />
(m)<br />
Minimum Width<br />
(m)<br />
Maximum Width<br />
(m)<br />
Security<br />
Rating<br />
Single leaf inward opening 2.44 0.6 3 2 999b/01<br />
security gate 1<br />
Double leaf inward opening<br />
security gate 1 2.44 1.2 6 2<br />
Cert.<br />
No.<br />
Compatible Locking Devices<br />
Reference Manufacturer Model Type Compatible operating devices Com patible<br />
External face Internal face<br />
cylinders<br />
1 Chubb B-3C16-PL-80 2 Mortice hook Key Key A and B<br />
lock<br />
2 Ingersoll London Line B- Mortice hook Key Key A and B<br />
SC110-CH 2 lock<br />
3 3 CLD Fencing<br />
Systems<br />
Drop bolt Drop bolt - Handle -<br />
Compatible Cylinders<br />
Reference Manufacturer Model Type<br />
A Eurospec CYA 74260PC Euro-profile double cylinder (key:key)<br />
B Mul-T-Lock Interactive Euro-profile double cylinder (key:key)<br />
Notes:<br />
1. The gate is available in configurations to suit either surface mounting onto hard surfaces 4 or embedding within concrete foundations<br />
placed in the ground 4 .<br />
2. Fitted with an LS2 cylinder guard supplied by Tindall Engineering Limited.<br />
3. This option is only available on double leaf gates. The security rating noted above will only be achieved if the primary locking device<br />
(i.e. those referenced as ‘1’ and ‘2’ in the compatible locking devices table) is engaged.<br />
4. It is important to ensure that the local ground onto/into which the gate is installed offers compatible strength.<br />
5. The gap between the gate posts and adjacent structures must not exceed 220 mm.<br />
6. The gap between the bottom of the gate leaf and the ground must not exceed 50 mm.<br />
The Expanded Metal Company Limited<br />
P.O.Box 14, Longhill Industrial Estate (North), Hartlepool TS25 1PR, United Kingdom<br />
Tel: +44 (0)1429 867 388 • Fax: +44 (0)1429 867 355<br />
E-mail: fencing@expamet.co.uk • Website: www.expandedmetalfencing.co.uk<br />
Certificate No: 731a to LPS 1175: Issue 5<br />
Vehicle and Pedestrian Gates<br />
Product<br />
Name<br />
Type Width (mm) Height<br />
(mm)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
Alleygator Pedestrian alley gate 810, 1000, 1100 and 2350 1 731a/01<br />
1600<br />
Vehicle alley gate 2150, 2300, 2450, 3010<br />
and 3300<br />
2350 1 731a/02<br />
490 20 Nov 2011
PART 4: SECTION 9.2<br />
SECURITY GATES<br />
Product<br />
Name<br />
Type Width (mm) Height<br />
(mm)<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
Vehicle alley gate incorporating inner 2150, 2300, 2450, 3010 2350 1 731a/03<br />
pedestrian alley gate<br />
and 3300<br />
Pedestrian alley gate<br />
810, 1000, 1100 and 2350 2 1 731a/04<br />
1600<br />
Vehicle alley gate 2150, 2300, 2450, 3010 2350 2 1 731a/05<br />
and 3300<br />
Vehicle alley gate incorporating inner<br />
pedestrian alley gate<br />
2150, 2300, 2450, 3010<br />
and 3300<br />
2350 2 1 731a/06<br />
Compatible locking systems<br />
Model Type Compatible<br />
Cylinders<br />
Wilka 5495<br />
Compatible accessories<br />
Self locking<br />
emergency exit<br />
mortice lock<br />
Approved Product (LPCB Ref. No. 731a/...)<br />
01 02 03 04 05 06<br />
Dom 333i5HT <br />
Model Type Approved Product (LPCB Ref. No. 731a/...)<br />
01 02 03 04 05 06<br />
Roller top 2 Anti-scaling<br />
attachment for top<br />
of gate<br />
<br />
Notes<br />
1. The deadlock must be fully thrown by turning the key twice in order for the gate to meet Security Rating 2.<br />
If the key is only thrown once the gate achieves Security Rating 1.<br />
2. The roller top option can be fitted without undermining the attack resistance provided by the gates.<br />
However, the roller top’s resistance to removal is not covered by this approval nor is its resistance to scaling.<br />
3. The gap between the gate and the adjacent walls must not exceed 45 mm.<br />
4. The gap between the bottom of the gate leaf and the ground must be within the following range:<br />
(i) 10 mm to 110 mm - Alleygator TM pedestrian alley gates.<br />
(ii) 50 mm to 150 mm - Alleygator TM vehicle alley gates and vehicle alley gates incorporating pedestrian gates.<br />
20 Nov 2011 491
PART 4: SECTION 9.3<br />
TURNSTILES<br />
Frontier-Pitts Limited<br />
Crompton House, Crompton Way, Manor Royal Industrial Estate, Crawley, West Sussex RH10 9QZ, United<br />
Kingdom<br />
Tel: +44 (0)1293 548301 • Fax: +44 (0)1293 560650<br />
E-mail: sales@frontierpitts.com • Website: www.frontierpitts.com<br />
Certificate No: 1059a to LPS 1175: Issue 6<br />
Full Height Turnstile<br />
Product Type<br />
Name<br />
Terra<br />
Diamond<br />
Grade 3<br />
Terra<br />
Diamond<br />
Grade 4<br />
Single full<br />
height<br />
turnstile<br />
Single full<br />
height<br />
turnstile<br />
Number of<br />
Rota Arms<br />
Walkway<br />
Width (m) 1<br />
Nominal<br />
Overall Unit<br />
Height (m) 2<br />
Nominal<br />
Overall Unit<br />
Width 2<br />
Nominal<br />
Overall Unit<br />
Depth 2<br />
Security<br />
3, 4, 5<br />
Rating<br />
Cert. No.<br />
Four 0.5 2.387 1.380 1.390 3 1059a/01<br />
Four 0.5 2.387 1.380 1.390 4 1059a/02<br />
Notes:<br />
1. This is measured at the outside entrance to the turnstile.<br />
2. These dimensions are of the entire unit. They include the enclosure above the rotor that contains the drive and control mechanism,<br />
but exclude those of the foundations.<br />
3. The turnstiles achieve these security ratings when installed and maintained in accordance with the instructions contained in the Terra<br />
Diamond Turnstile Operating and Maintenance Manual (document reference 6614-O&M Issue 4 dated 7 April 2011) and ‘Diamond<br />
Turnstile Installation Procedure (document reference 6614-IP Issue 2 dated 9 March 2011), placed in the ‘power to release’ (normal<br />
automatic) mode and operated from the ‘attack’ side using an access control system 6 having at least 30,000 effective differs that<br />
offers compatible resistance to manual attack.<br />
4. The turnstiles offer resistance to attack commensurate with at least Security Rating 1 when placed in the ‘manual release’ mode.<br />
5. The security ratings noted indicate the turnstile’s resistance to forced entry from the outside when mounted within barriers that offer<br />
compatible resistance to forced entry in accordance with LPS 1175: Issue 6.<br />
6. The resistance of the access control system, used to operate the turnstiles, to ‘non-mechanical’ attack is not covered as it is outside<br />
the scope of LPS 1175: Issue 6. Likewise, the approval does not cover possible effects of any susceptibilities relating to the<br />
functionality and performance of any access control equipment that may be used to operate the turnstiles. This is because the scope<br />
of access control devices and system configurations that may be used with these locking systems is “infinite”. It is therefore<br />
recommended that specifiers satisfy themselves that the components used are either resistant to mechanical and other forms of<br />
tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental<br />
conditions/interference that may cause the locking system to disengage.<br />
492 20 Nov 2011
PART 4: SECTION 10<br />
VEHICLE SECURITY BARRIER<br />
This <strong>section</strong> will include vehicle security barriers such as:<br />
Fixed bollards<br />
Rising bollards<br />
Road blockers<br />
Drop arm barriers<br />
Vehicle security barriers and their associated foundations will be evaluated against the requirements of PAS<br />
68: 2010 Impact test specifications for vehicle security barriers, a standard drawing on the draft LPS 1246<br />
Requirements and test methods for classifying security bollards originally developed by LPCB.<br />
Barriers are classified according to the following measurements after a single impact by a vehicle of a defined<br />
mass, velocity and angle of impact:<br />
The distance the vehicle passed beyond the plane of the barrier.<br />
The distance the major debris dispersed beyond the plane of the barrier.<br />
It is also intended that, where requested by the manufacturer, the barriers’ resistance to manual attacks aimed<br />
at compromising their resistance to vehicle attack will be rated in accordance with LPS 1175 Requirements<br />
and testing procedures for the LPCB approval and listing of intruder resistant building components,<br />
strongpoints, security enclosures and free-standing barriers.<br />
LPCB is also working closely with the Perimeter Security Suppliers Association (PSSA) and leading<br />
independent laboratories, such as TRL, to develop criteria evaluating and approving other aspects of the<br />
barriers performance and durability.<br />
This will enable specifiers to select vehicle barriers suitable to the risks identified during a risk assessment of<br />
the facilities to be protected.<br />
20 Nov 2011 493
PART 4: SECTION 11<br />
GAS CYLINDER SECURITY DEVICES<br />
This <strong>section</strong> lists gas cylinder security devices that have been approved to LPS 1175 Requirements and<br />
testing procedures for the LPCB approval and listing of intruder resistant building components,<br />
strongpoints, security enclosures and free-standing barriers.<br />
The approval covers the resistance to unauthorised removal of gas cylinders provided by the security devices<br />
when installed and maintained in accordance with the approved instructions.<br />
While previous versions of the standard specified six levels of resistance (security ratings), the latest version<br />
(Issue 6) specifies eight security ratings. These range from opportunist (1 minute attacks using easily<br />
concealable hand tools) up to extreme methods of attacks (20 minute attacks using a wide range of hand<br />
tools, power tools and thermal cutting equipment).<br />
Further details of the grading system can be found in the standard itself, copies of which are available free of<br />
charge and can be downloaded from www.<strong>RedBookLive</strong>.com.<br />
The approval does not cover the resistance to unauthorised operation of the gas cylinders when secured by<br />
the devices listed.<br />
Product Selection<br />
When selecting a gas cylinder security device, check that the product’s approval covers the types and sizes of<br />
cylinders to be secured, the compatible locking systems listed and the substrates to which the devices may be<br />
fixed in order to provide secure anchorage - all can affect the level of security provided by the product.<br />
To enable selection of the most appropriate product for the desired application, the listing defines the gas<br />
cylinders that are covered by the scope of approval in terms of the supplier, supplier reference and following<br />
dimensions:<br />
Key:<br />
h a = Height of cylinder, including foot ring and neck ring and/or valve cap<br />
h b = Height of cylinder to base of neck ring<br />
h c = Height of cylinder to edge of shoulder<br />
h d = Height of foot ring<br />
d a = Diameter at base of neck ring/valve cap<br />
d b = Diameter of cylinder<br />
To achieve the security ratings:<br />
(a) the gas cylinder security devices must be installed in accordance with the manufacturer’s instructions;<br />
494 20 Nov 2011
PART 4: SECTION 11<br />
GAS CYLINDER SECURITY DEVICES<br />
(b) all locks must be fully engaged and deadlocked; and<br />
(c) all exposed fixings, the substrate onto which each device is fitted and the locking mechanism(s) must be<br />
regularly checked to ensure they are in good condition and that they have not been tampered with.<br />
Liddle Doors Limited<br />
Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom<br />
Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698<br />
E-mail: liddle@liddledoors.co.uk • Website: www.liddledoors.co.uk<br />
Certificate No: 442c to LPS 1175: Issue 6<br />
Gas Cylinder Security Devices<br />
Product Name Model Type Compatible Gas<br />
Cylinders<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
Liddle Series 2 Bottle Storage LD Type A Three bottle storage 1, 4, 5 and 6 2 442c/01<br />
Frame<br />
(CL2)<br />
frame<br />
LD Type A Three bottle storage<br />
2 2<br />
(SO2)<br />
frame<br />
LD Type A Three bottle storage<br />
3 2<br />
(NH3)<br />
frame<br />
LD Type B Two bottle storage<br />
1, 4, 5 and 6 2<br />
(CL2)<br />
frame<br />
LD Type B Two bottle storage<br />
2 2<br />
(SO2)<br />
frame<br />
LD Type B Two bottle storage<br />
3 2<br />
(NH3)<br />
frame<br />
LD Type C Four bottle storage 1, 4, 5 and 6 2<br />
(CL2)<br />
frame<br />
LD Type C Four bottle storage<br />
2 2<br />
(SO2)<br />
frame<br />
LD Type C Four bottle storage<br />
3 2<br />
(NH3)<br />
frame<br />
LD Type D Six bottle storage<br />
1 2<br />
(CL2)<br />
frame<br />
LD Type D Six bottle storage<br />
2 2<br />
(SO2)<br />
frame<br />
LD Type F Single bottle storage 1, 4, 5 and 6 2<br />
(CL2)<br />
frame<br />
LD Type F Single bottle storage<br />
2 2<br />
(SO2)<br />
LD Type F<br />
(NH3)<br />
frame<br />
Single bottle storage<br />
frame<br />
3 2<br />
Compatible Locking Systems<br />
Model Type Cylinder<br />
Abloy PL340 Padlock Abloy High Profile<br />
Abloy PL340 Padlock Abloy Disklock Pro<br />
Abloy PL340 Padlock Abloy Exec<br />
Abloy PL340 Padlock Abloy Protec<br />
Abloy PL342 Padlock Abloy High Profile<br />
Abloy PL342 Padlock Abloy Disklock Pro<br />
Abloy PL342 Padlock Abloy Exec<br />
Abloy PL342 Padlock Abloy Protec<br />
Compatible Gas Cylinders<br />
20 Nov 2011 495
PART 4: SECTION 11<br />
GAS CYLINDER SECURITY DEVICES<br />
Cylinder<br />
Reference<br />
Supplier<br />
Model<br />
Reference<br />
Height 3 (mm)<br />
Diameter 3 (mm)<br />
Notes<br />
h a h b h c h d d a d b<br />
1 BOC BKA 1120 1000 930 65 75 300<br />
2 BOC BD 910 780 700 60 140 320<br />
3 BOC BE 1265 1120 1035 85 90 380<br />
4 BOC E3 1060 940 890 45 75 220<br />
5 Ineos 71kg 1130 1020 950 65 85 290<br />
6 Ineos 33kg 1050 940 840 n/a 85 220<br />
1. The 'Liddle Series 2 Bottle Storage Frames' are approved when installed directly onto a flat solid concrete floor.<br />
2. The security rating afforded to the 'Liddle Series 2 Bottle Storage Frames' is based upon every bay within the frame containing a<br />
cylinder of the relevant type and dimensions specified.<br />
3. For a key to the cylinder dimensions refer to the introduction of the gas cylinder security device <strong>section</strong> of the Red Book<br />
(<strong>RedBookLive</strong>.com).<br />
Technocover Limited (incorporating TechnoRail and Strataform)<br />
Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom<br />
Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527<br />
E-mail: techadvice@technocover.co.uk • Website: www.technocover.co.uk<br />
Certificate No: 450e to LPS 1175: Issue 6<br />
Gas Cylinder Security Devices<br />
Product Name Type Gas Cylinders Security Rating Cert. No.<br />
Ultrasecure Cylinder Clamp Single cylinder clamp 1, 2, 3, 4 and 5 2 450e/01<br />
Compatible Locking Systems<br />
Model Type Cylinder<br />
Abloy PL340 Padlock Abloy Disklock Pro<br />
Abloy PL340 Padlock Abloy Protec<br />
Kaba K20SS65L Padlock Kaba 20 (Armoured)<br />
Kaba Thorlock Integral lock Kaba 20 (Armoured)<br />
Compatible Gas Cylinders<br />
Cylinder<br />
Reference<br />
Note<br />
Supplier<br />
Model<br />
Reference<br />
Height (mm)<br />
Diameter<br />
(mm)<br />
h a h b h c h d d a d b<br />
1 IneosChlor 71 kg 1130 1020 950 65 85 290<br />
2 IneosChlor 33 kg 1050 940 840 n/a 85 220<br />
3 BOC BKA 1120 1000 930 65 75 300<br />
4 BOC E3 1060 940 890 45 75 220<br />
5 BOC BD 910 780 700 60 140 320<br />
1. The device is approved when installed in accordance with document CCU-DV-FIT-01 (Issue 2).<br />
496 20 Nov 2011
PART 4: SECTION 12<br />
PHYSICAL SECURITY DEVICES FOR COMPUTERS AND OTHER ICT EQUIPMENT<br />
At the request of the Association of British Insurers, the LPCB developed LPS 1214 Specification for testing<br />
and classifying physical protection devices for personal computers and similar equipment for the performance<br />
of security equipment designed to prevent removal of computer and other office equipment:<br />
The standard currently defines two categories of protection. Both categories of device prevent theft of the<br />
complete computer for three minutes allowing a response by Police or security guards, while Category II<br />
products also prevent removal of the computer chips for the same period.<br />
Suitable applications for products certified to LPS 1214 are described below:<br />
Category I:<br />
Category II:<br />
Prevent unauthorised removal of personal computers (PCs), file<br />
servers, printers, facsimile machines and other high value equipment<br />
for example where access is important for use and the component<br />
value is low.<br />
Prevent unauthorised removal of or access to personal computers<br />
(PCs), file servers, printers, facsimile machines and other high value<br />
equipment for example where the PC is both important and highly<br />
valued and/or the component value is high.<br />
Specifiers requiring category II devices should ensure that they select a device suitable for their <strong>part</strong>icular<br />
equipment and that there is suitable ventilation of the computer in accordance with any instructions and<br />
warranty conditions supplied with the computer.<br />
In order that they will provide the required protection, the approved equipment must be installed in accordance<br />
with the manufacturer’s instructions and be in the locked condition with keys removed and held in a secure<br />
location.<br />
It is recommended that users regularly check that all exposed fixings and locking mechanisms are in good<br />
condition and that they have not been tampered with.<br />
In addition to approving physical protection devices for personal computers and similar equipment to LPS<br />
1214, LPCB also evaluate and approve the following equipment designed to secure larger volumes of ICT<br />
equipment to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder<br />
resistant building components, strongpoints, security enclosures and free-standing barriers:<br />
- Racking systems<br />
- Modular enclosures<br />
- Composite panelling systems designed for constructing data halls.<br />
Security products approved to LPS 1175 Security Rating 2 provide an equivalent resistance to forced entry as<br />
that provided by an LPS 1214 Category I device.<br />
It should be noted that the resistance provided by each enclosure approved to LPS 1214 category I or LPS<br />
1175 Security Rating 2 used to secure individual items of ICT equipment matches the resistance provided by<br />
products, such as doors and <strong>part</strong>itioning systems, rated to Security Rating 2 in LPS 1175 that secure larger<br />
quantities of ICT equipment. It is therefore recommended that specifiers individually secure items of ICT<br />
equipment especially when located in multi-user spaces, such as schools and offices, and open access areas<br />
such as libraries.<br />
It is also recommended that all equipment is marked with an asset management marking system approved to<br />
LPS 1225 and registered on a secure asset database certified to LPS 1224. Marking devices and secured<br />
database services are listed in Sections 13 and 14 of Part 4.<br />
Products that have been certified by LPCB should be marked with a label indicating the level of security<br />
offered, LPCB certification mark and certificate number.<br />
20 Nov 2011 497
PART 4: SECTION 12<br />
PHYSICAL SECURITY DEVICES FOR COMPUTERS AND OTHER ICT EQUIPMENT<br />
Bradbury Security<br />
Dunlop Way, Queensway Industrial Estate, Scunthorpe DN16 3RN, United Kingdom<br />
Tel: +44 (0)1724 271999 • Fax: +44 (0)1724 271888<br />
E-mail: sales@bradburyuk.com • Website: www.bradburyuk.com<br />
Certificate No: 312b to LPS 1214: Issue 2<br />
Server Security Cabinets<br />
Product<br />
Name<br />
Type Model Height<br />
(mm)<br />
Width<br />
(mm)<br />
Depth<br />
(mm)<br />
Security<br />
Category<br />
Cert.<br />
No.<br />
Ventis Server Server enclosure with<br />
- 2127 725 1100 II 312b/03<br />
Safe single door in front and rear<br />
Sun Safe Server enclosure with UKT-SUNSAFE-1 2160 725 1500 II<br />
System Vault single door in front and rear<br />
Server enclosure with UKT-SUNSAFE-2 2160 725 1265 II<br />
single door in front and rear<br />
Server enclosure with UKT-SUNSAFE-3 2160 725 1100 II<br />
single door in front and rear<br />
Server enclosure with UKT-SUNSAFE-6 1000 725 1000 II<br />
single door in front and rear<br />
Server enclosure with UKT-SUNSAFE-7 1000 725 900 II<br />
single door in front and rear<br />
Server enclosure with Made to measure: 1000 600 600 II<br />
single door in front and rear min. size<br />
Server enclosure with Made to measure: 2500 1000 2000 II<br />
single door in front and rear max. size<br />
Server enclosure with UKT-SUNSAFE-4 2160 1000 1500 II<br />
double door in front and<br />
rear<br />
Server enclosure with UKT-SUNSAFE-5 2160 1000 1853 II<br />
double door in front and<br />
rear<br />
Server enclosure with UKT-SUNSAFE-8 2160 1000 1265 II<br />
double door in front and<br />
rear<br />
Server enclosure with<br />
double door in front and<br />
rear<br />
Made to measure:<br />
min. size<br />
1000 700 600 II<br />
Server enclosure with<br />
double door in front and<br />
rear<br />
Made to measure:<br />
max. size<br />
2500 2000 2000 II<br />
Compatible Locks<br />
Lock Type Cylinder<br />
Dom Nemef DDLK Mortice Lock Mul-T-Lock Interactive single Euro-profile cylinder<br />
or<br />
Santos 725 single Euro-profile cylinder<br />
Notes<br />
1. The above approval applies to these products when assembled and installed strictly in accordance with the instructions provided<br />
with the product.<br />
2. In order to offer the required level of security, all locks must be engaged and the keys removed.<br />
Dalen Limited<br />
Valepits Road, Garretts Green Industrial Estate, Birmingham B33 0TD, United Kingdom<br />
Tel: +44 (0)121 783 3838 • Fax: +44 (0)121 784 6348<br />
E-mail: sales@top-tec.co.uk • Website: www.top-tec.co.uk<br />
Certificate No: 276a to LPS 1214: Issue 2<br />
498 20 Nov 2011
Computer Security Devices<br />
Product<br />
Name<br />
Type Maximum<br />
Computer<br />
Height<br />
(mm)<br />
T-T450/1 Adjustable<br />
tower<br />
computer<br />
security cage<br />
T-T450/2 Adjustable<br />
tower<br />
computer<br />
security cage<br />
T-T460/2 Adjustable<br />
tower<br />
computer<br />
T-T418<br />
(4)<br />
T-T419<br />
T-T540<br />
Nightsafe<br />
security cage<br />
Front<br />
opening<br />
bespoke<br />
range of<br />
security<br />
entrapments<br />
for tower<br />
computers<br />
Front<br />
opening<br />
bespoke<br />
range of<br />
security<br />
entrapments<br />
for tower<br />
computers<br />
PART 4: SECTION 12<br />
PHYSICAL SECURITY DEVICES FOR COMPUTERS AND OTHER ICT EQUIPMENT<br />
Maximum<br />
Computer<br />
Width<br />
(mm)<br />
Maximum<br />
Computer<br />
Depth<br />
(mm)<br />
Minimum<br />
Computer<br />
Height<br />
(mm)<br />
Minimum<br />
Computer<br />
Width<br />
(mm)<br />
Minimum<br />
Computer<br />
Depth<br />
(mm)<br />
Security<br />
Category<br />
Cert.<br />
No.<br />
380 190 - 330 165 440 I 276a/01<br />
430 190 - 380 165 440 I 276a/02<br />
180 515 700 100 300 355 I 276a/03<br />
700 400 700 250 180 300 I 276a/04<br />
300 800 700 110 200 350 I 276a/05<br />
Modular<br />
laptop<br />
security<br />
enclosures 3 500 250 500 330 95 330 II 276a/06<br />
Notes<br />
1. The approval applies to these products when installed strictly in accordance with the instructions provided with the product.<br />
2. The substrate and fixings for wall and floor mounting may affect the performance of the product and are therefore outside the scope<br />
of the approval.<br />
3. The Nightsafe units are modular units available with between three and nine com<strong>part</strong>ments each designed to take computers within<br />
the size range specified above.<br />
4. The T-T418 may also be sold under the alternative model reference T-T SE 0250.<br />
Certificate No: 276b to LPS 1214: Issue 2<br />
Projector Security Devices<br />
Product Name Cage<br />
Dimensions<br />
Cage<br />
Dimensions<br />
Cage<br />
Dimensions<br />
Pole<br />
Length<br />
Pole<br />
Length<br />
Security<br />
Category<br />
Cert.<br />
No.<br />
Depth<br />
(mm)<br />
Width<br />
(mm)<br />
Height<br />
(mm)<br />
Minimum<br />
(mm)<br />
Maximum<br />
(mm)<br />
T-T140/3 Projector 386 319 115 500 1500 I 276b/01<br />
cage<br />
T-T140/4 Projector<br />
cage<br />
386 319 140 500 1500 I 276b/02<br />
Suitable for use with the projectors within the following size range:<br />
Product Name<br />
Minimum<br />
Maximum<br />
Depth<br />
(mm)<br />
Width<br />
(mm)<br />
Height<br />
(mm)<br />
Depth<br />
(mm)<br />
Width<br />
(mm)<br />
Height<br />
(mm)<br />
T-T140/3 Projector cage 150 150 50 225 340 95<br />
T-T140/4 Projector cage 150 150 50 225 340 115<br />
Compatible locks<br />
20 Nov 2011 499
PART 4: SECTION 12<br />
PHYSICAL SECURITY DEVICES FOR COMPUTERS AND OTHER ICT EQUIPMENT<br />
Lock Designation<br />
T-T140 (LPCB Ref. No. 276b/...)<br />
01 02<br />
Lowe and Fletcher 10 pin radial tumbler lock <br />
Manseng Enterprise Co. Ltd, 7 pin radial push button lock <br />
Note<br />
1. The approval only applies to the projector cages when used in conjunction with the T-T105 pole and T-T105-CU ceiling unit, and<br />
installed strictly in accordance with the following instructions:<br />
T-T140 iss5.pub<br />
CC_INST T-T 105-CU iss3.pub<br />
CC_INST T-T 105-Pole iss1.pub<br />
500 20 Nov 2011
PART 4: SECTION 13<br />
DATABASE MANAGEMENT FOR ASSET MARKING<br />
The essential requirements of LPS 1224:Issue 2 Requirements for Secure Database Registers were<br />
developed as a result of needs identified by the Police, Insurers and Home Office. LPS 1224 ensured that<br />
Police and other legitimate enquirers can confirm ownership of property 24 hours a day while ensuring full<br />
details of property ownership are held securely and in accordance with the Data Protection Act.<br />
Therefore, under the requirements of LPS 1224, the database operator must:<br />
(i) Have an established track record in the field of asset registration of at least one year.<br />
(ii) Operate the database in accordance with a documented set of procedures in accordance with the<br />
requirements defined in LPS 1224.<br />
(iii) Offer a telephone check line service manned by trained operatives. In accordance with Government<br />
policy, the service shall be available 24 hour a day access and shall be free of direct charge to the enquirer,<br />
e.g. it shall not chargeable to the enquirer as a premium rate telephone service.<br />
This <strong>section</strong> lists companies that run databases that have been assessed and approved to LPS 1224. More<br />
recently LPS 1224:Issue 3 Requirements for companies providing security asset registration services was<br />
developed. This covers database services provided over the internet as well as those which may be accessed<br />
using other media.<br />
Datatag ID Limited<br />
3000 Hillswood Drive, Hillswood Business Park, Chertsey, Surrey KT16 0RS, United Kingdom<br />
Tel: +44 (0)1932 895304 • Fax: +44 (0)1932 796797<br />
E-mail: info@datatag.co.uk • Website: www.datatag.co.uk<br />
24/7 Telephone Number: 0845 0700 440<br />
Certificate No: 665a to LPS 1224: Issue 2<br />
Secure Database Register<br />
Product Name Telephone Number Web Address Cert. No.<br />
Datatag ID Secure Database 08450 700440 as above 665a/01<br />
Retainagroup Limited<br />
Unit 5, St John's Court, Foster Road, Ashford Business Park, Ashford, Kent TN24 0SJ, United Kingdom<br />
Tel: +44 (0)1233 506400 • Fax: +44 (0)1233 506401<br />
E-mail: cust.service@retainagroup.co.uk • Website: www.retainagroup.com<br />
Certificate 493a<br />
5 Windward House, Plantation Wharf, London SW11 3TU, United Kingdom<br />
Tel: 24 hour 07000 111333<br />
Certificate No: 493a to LPS 1224: Issue 2<br />
Secure Database Register<br />
Product Name Telephone Number Web Address Cert. No.<br />
International Security Register 07000 111333 As above 493a/01<br />
20 Nov 2011 501
PART 4: SECTION 13<br />
DATABASE MANAGEMENT FOR ASSET MARKING<br />
Selectamark Security Systems plc<br />
1 Locks Court, 429 Crofton Road, Locksbottom, Kent BR6 8NL, United Kingdom<br />
Tel: +44 (0)1689 860757 • Fax: +44 (0)1689 860693<br />
E-mail: sales@selectamark.co.uk • Website: www.selectadna.co.uk<br />
Certificate No: 497b to LPS 1224: Issue 3<br />
Secure Database Register<br />
Product Name Telephone<br />
Number<br />
Selectamark +44 (0)1689<br />
Secure Asset 860757<br />
Register<br />
Hours of Operation 1 Web Address Postal<br />
Address<br />
9 am to 5 pm on<br />
www.<br />
1 Locks<br />
weekdays, excluding secureassetregister.com Court,<br />
bank holidays<br />
429 Crofton<br />
Road,<br />
Locksbottom<br />
Kent BR6<br />
8NL<br />
Security Cert.<br />
Level No.<br />
2 497b/01<br />
Note:<br />
1. These are the hours during which the telephone helpline is available. These are based on UK time.<br />
502 20 Nov 2011
PART 4: SECTION 14<br />
ASSET MARKING SYSTEMS<br />
The following marking devices listed have been tested to LPS 1225 Specification for testing and classifying<br />
asset marking systems.<br />
LPS 1225 specifies requirements for the composition and performance of an asset marking system such that,<br />
when used according to the manufacturer’s instructions, the asset marking device may:<br />
i) Enable the marked asset to be traced to the legal owner via a secure database register linked to the<br />
marking system employed.<br />
ii)<br />
Act as a theft deterrent in the first instance by virtue of known existence.<br />
It is assumed that the <strong>part</strong> of the asset to which the asset marking device is applied is at least equal in<br />
resistance to removal from the asset as the asset marking device employed.<br />
The two-<strong>part</strong> classification indicates the resistance of the product to eradication of ownership traceability and<br />
resistance to complete removal of marking without leaving evidence of previous existence. This gives the enduser<br />
the option of selecting a product to suit the required application. Complete removal of the marking and<br />
restoration of the asset gives maximum resale value to the stolen asset; however the standard does not take<br />
into account replication or replacement of components as <strong>part</strong> of asset restoration.<br />
The overall classification designation achieved is given by two numerals separated by a plus sign. The first<br />
numeral represents the resistance rating to erasure of traceability and the second numeral to complete<br />
removal/asset restoration.<br />
The two classifications are both on a scale of one to eight. Classification ‘1’ performance relates to that which<br />
should be expected as a minimum for marking devices used in the retail trade and other public areas<br />
equipped with CCTV and security staff. Classification ‘8’, on the other hand, is aimed at marking devices<br />
applied to assets that have a high value and this will be the subject of a more determined level of effort by the<br />
criminal in order to prevent traceability or completely remove the mark.<br />
Long term durability of the system and associated components are beyond the scope of this standard, as are<br />
the performance requirements of any covert marking technology incorporated in the system.<br />
Although this standard specifies that the product instructions shall include hazard data, confirmation of the<br />
authenticity of such data is not addressed.<br />
All approved marking devices are marked with a unique asset identification code. The LPCB certification mark<br />
and reference numbers relating to the marking device and database, and the telephone number of the<br />
database will also be marked on the marking device, or where this is not viable, on separate warning labels<br />
which are supplied with the marking device.<br />
In addition to LPS 1225, LPCB is currently working with manufacturers and specifiers to finalise standards<br />
classifying the performance of “microdot”, “trace chemical” and RFID marking systems. Please contact LPCB<br />
for further details.<br />
20 Nov 2011 503
PART 4: SECTION 14<br />
ASSET MARKING SYSTEMS<br />
Retainagroup Limited<br />
Unit 5, St John's Court, Foster Road, Ashford Business Park, Ashford, Kent TN24 0SJ, United Kingdom<br />
Tel: +44 (0)1233 506400 • Fax: +44 (0)1233 506401<br />
E-mail: cust.service@retainagroup.co.uk • Website: www.retainagroup.com<br />
Certificate 493b<br />
5 Windward House, Plantation Wharf, London SW11 3TU, United Kingdom<br />
Tel: 24 hour 07000 111333<br />
Certificate No: 493b to LPS 1225: Issue 3<br />
Overt Asset Marking Systems<br />
Product Name Substrate Resistance<br />
Rating<br />
Classification<br />
Database<br />
Ref. No.<br />
The Retainagroup Marking and Registration System for Vehicles Float glass 2 + 8 493a/01 493b/01<br />
Marking and Registration System for Vehicles<br />
Laminated 2 + 8 493a/01<br />
glass<br />
Toughened 2 + 8 493a/01<br />
glass<br />
The Retainagroup Marking and Registration System for Office and<br />
Household Equipment<br />
ABS Plastic 1 + 2 493a/01 493b/02<br />
Cert.<br />
No.<br />
Note<br />
1. Effective marking of materials, in <strong>part</strong>icular plastics, is dependent upon the specific material type, material constituents and surface<br />
finish. If you are in any doubt over the likely performance of these marking devices in your situation please contact the<br />
manufacturer.<br />
Selectamark Security Systems plc<br />
1 Locks Court, 429 Crofton Road, Locksbottom, Kent BR6 8NL, United Kingdom<br />
Tel: +44 (0)1689 860757 • Fax: +44 (0)1689 860693<br />
E-mail: sales@selectamark.co.uk • Website: www.selectadna.co.uk<br />
Certificate No: 497a to LPS 1225: Issue 3<br />
Overt Asset Marking Systems<br />
Product Name<br />
Type of<br />
Marking<br />
Substrate<br />
Resistance<br />
Rating<br />
Database<br />
Ref. No.<br />
Cert.<br />
No.<br />
Device<br />
Classification<br />
Selectamark Glass etching compound Float glass 1 + 8 379a 497a/01<br />
(7mm)<br />
'Blue' etching compound ABS plastic 1 + 2 379a 497a/02<br />
'Blue' etching compound Enamel finished steel 1 + 1 379a<br />
'Blue' etching compound Leather 1 + 2 379a<br />
'Blue' etching compound Polycarbonate 2 + 5 379a<br />
'Blue' etching compound<br />
Polymethyl Methacrylate<br />
1 + 3 379a<br />
("Perspex")<br />
'Blue' etching compound Planed softwood timber 1 + 1 379a<br />
'Blue' etching compound Planed hardwood timber 1 + 1 379a<br />
'Blue' etching compound Plywood 1 + 1 379a<br />
'Blue' etching compound PVC 1 + 2 379a<br />
'UV-Orange' etching compound ABS plastic 1 + 2 379a 497a/03<br />
'UV-Orange' etching compound Enamel finished steel 1 + 1 379a<br />
'UV-Orange' etching compound Leather 1 + 2 379a<br />
'UV-Orange' etching compound Polycarbonate 2 + 5 379a<br />
'UV-Orange' etching compound Polymethyl Methacrylate<br />
1 + 3 379a<br />
("Perspex")<br />
'UV-Orange' etching compound Planed softwood timber 1 + 1 379a<br />
'UV-Orange' etching compound Planed hardwood timber 1 + 1 379a<br />
504 20 Nov 2011
PART 4: SECTION 14<br />
ASSET MARKING SYSTEMS<br />
Product Name<br />
Supermark<br />
(5mm)<br />
Selectamark<br />
(5mm)<br />
Selectamark<br />
(7mm)<br />
Supermark<br />
(5mm)<br />
Type of<br />
Marking<br />
Device<br />
Substrate<br />
Resistance<br />
Rating<br />
Classification<br />
Database<br />
Ref. No.<br />
'UV-Orange' etching compound Plywood 1 + 1 379a<br />
'UV-Orange' etching compound PVC 1 + 2 379a<br />
Label and 'Blue' etching compound ABS plastic 1 + 3 379a 497a/04<br />
Label and 'Blue' etching compound Enamel finish steel 1 + 2 379a<br />
Label and 'Blue' etching compound Polycarbonate 1 + 4 379a<br />
Label and 'Blue' etching compound Polypropylene 1 + 2 379a<br />
Label and 'Blue' etching compound Polymethyl Methacrylate<br />
1 + 4 379a<br />
("Perspex")<br />
Label and 'Blue' etching compound Planed softwood timber 1 + 2 379a<br />
Label and 'Blue' etching compound Planed hardwood timber 1 + 2 379a<br />
Label and 'Blue' etching compound Plywood 1 + 2 379a<br />
Label and 'Blue' etching compound PVC 1 + 3 379a<br />
Label and 'UV-Orange' etching<br />
ABS plastic 1 + 3 379a 497a/05<br />
compound<br />
Label and 'UV-Orange' etching Enamel finished steel 1 + 2 379a<br />
compound<br />
Label and 'UV-Orange' etching<br />
Polycarbonate 1 + 4 379a<br />
compound<br />
Label and 'UV-Orange' etching<br />
Polypropylene 1 + 2 379a<br />
compound<br />
Label and 'UV-Orange' etching Polymethyl Methacrylate<br />
1 + 4 379a<br />
compound<br />
("Perspex")<br />
Label and 'UV-Orange' etching Planned softwood timber 1 + 2 379a<br />
compound<br />
Label and 'UV-Orange' etching Planed hardwood timber 1 + 2 379a<br />
compound<br />
Label and 'UV-Orange' etching<br />
Plywood 1 + 2 379a<br />
compound<br />
Label and 'UV-Orange' etching<br />
compound<br />
PVC 1 + 3 379a<br />
'Blue' etching compound ABS plastic 1 + 2 379a 497a/02<br />
'Blue' etching compound Enamel finished steel 1 + 1 379a<br />
'Blue' etching compound Polycarbonate 2 + 5 379a<br />
'Blue' etching compound<br />
Polymethyl Methacrylate<br />
1 + 3 379a<br />
("Perspex")<br />
'Blue' etching compound PVC 1 + 2 379a<br />
'Ice Blue' etching compound ABS plastic 1 + 2 379a 497a/07<br />
'Ice Blue' etching compound Enamel finished steel 1 + 1 379a<br />
'Ice Blue' etching compound Polycarbonate 2 + 5 379a<br />
'Ice Blue' etching compound Polymethyl Methacrylate<br />
1 + 3 379a<br />
("Perspex")<br />
'Ice Blue' etching compound PVC 1 + 2 379a<br />
'Ice Blue' etching compound ABS plastic 1 + 2 379a<br />
'Ice Blue' etching compound Enamel finished steel 1 + 2 379a<br />
'Ice Blue' etching compound Polycarbonate 2 + 5 379a<br />
'Ice Blue' etching compound Polymethyl Methacrylate<br />
1 + 3 379a<br />
("Perspex")<br />
'Ice Blue' etching compound PVC 1 + 2 379a<br />
Label and 'Ice Blue' etching<br />
ABS plastic 1 + 3 379a 497a/06<br />
compound<br />
Label and 'Ice Blue' etching<br />
Enamel finished steel 1 + 2 379a<br />
compound<br />
Label and 'Ice Blue' etching<br />
Polycarbonate 1 + 4 379a<br />
compound<br />
Label and 'Ice Blue' etching Polymethyl Methacrylate<br />
1 + 4 379a<br />
compound<br />
("Perspex")<br />
Label and 'Ice Blue' etching<br />
Polypropylene 1 + 2 379a<br />
compound<br />
Label and 'Ice Blue' etching<br />
PVC 1 + 3 379a<br />
compound<br />
Cert.<br />
No.<br />
Note<br />
1. Effective marking of materials, in <strong>part</strong>icular plastics, is dependent upon the specific material type, material constituents surface<br />
colour and finish. If you are in any doubt over the likely performance of these marking devices in your situation please contact the<br />
manufacturer.<br />
20 Nov 2011 505
PART 4: SECTION 15<br />
'THEFT RESISTANT' ELECTRONIC PRODUCTS<br />
This <strong>section</strong> lists ‘theft resistant’ electronic products that have been assessed to LPS 1650 Requirements and<br />
testing procedures for the LPCB approval and listing of ‘theft resistant’ electronic products. This includes:<br />
• In-car entertainment systems • PDA’s<br />
• DVD players and writers • Personal computers<br />
• Health care equipment • Projectors and wipe boards<br />
• Laptops • Printers<br />
• Mobile telephones • Satellite navigation devices<br />
• MP3 players • Televisions and screens<br />
The attributes that make these products <strong>part</strong>icularly desirable to thieves can be summarised into six elements<br />
and these elements are often referred to by the acronym CRAVED. Concealable, Removable, Available,<br />
Valuable, Enjoyable and Disposable. Whilst each element can be used to determine which products are likely<br />
to be stolen, the frequency at which the thefts occur may ultimately depend on just one attribute, the ease at<br />
which the item can be disposed.<br />
The intention of LPS 1650 is to encourage the use of effective security features that make it difficult to return<br />
the product to a ‘re-saleable’ condition if stolen, thus reducing the level to which they are craved by criminals.<br />
Whilst the standard does not specify any one <strong>part</strong>icular design of anti-theft technology it includes<br />
requirements for the performance of the following types:<br />
• Denial of service technologies, such as PIN codes, removal<br />
coded panels and electronic keys<br />
• Asset marking systems (overt and covert) linked to secure<br />
databases providing traceability to the legal owner of the<br />
product<br />
• Anchoring devices providing mechanical resistance against<br />
unauthorised removal of the product<br />
• Alarm /signalling technologies providing warning of attempted<br />
removal<br />
– Use of effective denial of service technology can prevent the<br />
product being enjoyed by persons other than the legitimate<br />
owner(s).<br />
– Asset marking that cannot be removed without damaging the<br />
product can make it harder for the thief to dispose of the item<br />
and reduce the value of the goods if removal is attempted.<br />
– Secure fixing to a solid mounting surface can increase the<br />
effort required to remove the product.<br />
– An audible alarm could make the product less concealable.<br />
The requirements and tests of LPS 1650 permit the assessment and rating of the performance of the anti-theft<br />
security features built into or supplied with the product.<br />
Where appropriate reference is made to specific requirements of standards such as LPS 1224 Requirements<br />
for secure database registers, LPS 1225 Requirements for the LPCB approval and listing of asset marking<br />
systems, LPS 1214 Specification for testing and classifying physical protection devices for personal<br />
computers and similar equipment and a number of other applicable European standards.<br />
The overall security performance rating is indicated by a series of security performance classifications. To<br />
meet the minimum requirement of LPS 1650 products must achieve at least one denial of service<br />
classification. The security performance rating is expressed in the following format:<br />
506 20 Nov 2011
PART 4: SECTION 15<br />
'THEFT RESISTANT' ELECTRONIC PRODUCTS<br />
For details of the security performance rating parameters and their classification refer to LPS 1650.<br />
20 Nov 2011 507
PART 4: SECTION 16<br />
LETTER PLATES AND LETTER BOXES (MAIL BOXES)<br />
Letter plates and letter boxes (otherwise known as mail boxes) listed within this <strong>section</strong> have been evaluated<br />
in accordance with either LPS 1175 Specification for testing and classifying the burglary resistance of building<br />
components, strongpoints and security enclosures or BS EN 13724: 2002 Postal services - Apertures of<br />
private letter boxes and letter plates - Requirements and test methods.<br />
LPS 1175 currently specifies eight grades of security according to the severity of the likely attack ranging from<br />
opportunists (security rating 1) through to professional criminals. The ratings are determined in terms of attack<br />
tools and time available to the attacker, and enables specifiers to select products according to the risks that<br />
they and their property face. The failure criteria used will suit the intended application of the products listed.<br />
These may include boxes designed to prevent the unauthorised removal of the contents of a letter box to<br />
letter plates and boxes with lockable flaps that are designed to prevent deliveries being made during periods<br />
when the properties to which they are fitted are left empty.<br />
Details regarding the classification system used when rating products to LPS 1175 can be found within the<br />
standard itself, copies of which are available free of charge and can be downloaded from the LPCB web site<br />
www.<strong>RedBookLive</strong>.com.<br />
BS EN 13724: 2002 classifies apertures of letter boxes and plates according to the following:<br />
Type of aperture<br />
Size of aperture<br />
Corrosion resistance and water penetration<br />
Security.<br />
The classification is determined by taking a series of measurements and conducting a series of mechanical<br />
tests including soak tests (water), salt spray tests to EN 1670 (corrosion) and load tests (security). The<br />
security requirements contained within BS EN 13724: 2002 are considered to be less severe than those of the<br />
minimum security rating defined in LPS 1175, i.e. Security Rating 1.<br />
It is important to ensure that the letter plates and boxes are installed in accordance with the manufacturers<br />
instructions and that all exposed fixings, the substrate to which the product is fitted, and any locking<br />
mechanisms incorporated within the product are regularly checked to ensure that they are in good condition<br />
and that they have not been tampered with.<br />
The Safety Letter Box Company Limited<br />
Unit 1B, Milland Industrial Estate, Milland Road, Neath, West Glamorgan SA11 1NJ, United Kingdom<br />
Tel: +44 (0)1639 633525 • Fax: +44 (0)1639 646359<br />
E-mail: info@safetyletterbox.com • Website: www.safetyletterbox.com<br />
Certificate No: 962a to LPS 1175: Issue 6<br />
Security Letter plate<br />
Product<br />
Name<br />
Type Scope of Installation Security<br />
Rating<br />
Cert.<br />
No.<br />
Flaplock<br />
FL05<br />
Internal letter<br />
plate<br />
Mounting on the rear of 44 mm thick solid timber door leaves over letter<br />
slots measuring 45 mm by 250 mm<br />
1 962a/01<br />
Function<br />
508 20 Nov 2011
PART 4: SECTION 16<br />
LETTER PLATES AND LETTER BOXES (MAIL BOXES)<br />
The ‘Flaplock5’ helps to prevent the following when installed in accordance with the instructions contained on the<br />
document ‘FL05 FIT INST Rev 1’ and the flap is secured by inserting the pegs provided into the yolks located at<br />
both ends of the flap:<br />
- Insertion of litter, mail and other unwanted items into the property via the letter plate aperture.<br />
- Removal of keys and other items from within the property via the letter plate aperture1.<br />
- Access to locking hardware fitted to the door via the letter plate aperture by those attempting to gain<br />
unauthorised entry into the property by operating such hardware.<br />
Note<br />
1. It is recommended that such items are not stored within the immediate proximity of the letter plate.<br />
20 Nov 2011 509
PART 4: SECTION 17<br />
KEY SAFES<br />
Key safes listed in this <strong>section</strong> are approved to LPS 1175 Requirements and testing procedures for the LPCB<br />
approval and listing of intruder resistant building components, strongholds, security enclosures and freestanding<br />
barriers.<br />
Unless otherwise stated, the security rating attributed to each key safe listed in this <strong>section</strong> relates to the key<br />
safes’ resistance to the following methods of attack:<br />
Forced entry into the key safe to remove a key stored within it.<br />
Unauthorised removal of the key safe from the supporting substrate.<br />
It is recommended that the security ratings of the key safes used to store keys are at least equivalent to those<br />
of the products (e.g. doorsets) the keys operate. This is <strong>part</strong>icularly important if the key safes are located in<br />
unprotected areas, for example, on the outside of properties. This is to ensure the key safes do not<br />
compromise the resistance to forced entry provided by the products that the keys operate.<br />
UTC Fire & Security B.V.<br />
Kelvinstraat 7, 6003 DH, Weert, The Netherlands<br />
Tel: +31 495 583000 • Fax: +31 495 550042<br />
E-mail: esther.franken@fs.utc.com<br />
Europe, Middle East, Africa sales:<br />
UTC Fire & Security, Supra Asset Protection Solutions, Kouterveldstraat 2, B-1831 Diegem, Belgium<br />
Tel: +32 478 98 32 81<br />
E-mail: didier.trehout@fs.utc.com<br />
UK sales:<br />
Supra UK Ltd, 24 The Furlong, Berry Hill Industrial Estate, Droitwich Spa, Worcestershire WR9 9AH, United<br />
Kingdom<br />
Tel: +44 (0)1905 770333<br />
E-mail: sales@keysafe.co.uk<br />
Certificate No: 1062a to LPS 1175: Issue 6<br />
Key Safes<br />
Product Name Model Part<br />
No.<br />
Instructions<br />
Supra P500 Wall mounted key safe with twelve button 002045 P/N10102761P1<br />
combination<br />
December 2009<br />
Supra Consumer 500 Wall mounted key safe with twelve button 002049 P/N10102770P1<br />
combination<br />
December 2009<br />
Supra P500 with Wall mounted key safe with twelve button 002046 P/N10102761P1<br />
alarm switch<br />
Supra Consumer 500<br />
with alarm switch<br />
combination incorporating an alarm switch<br />
Wall mounted key safe with twelve button<br />
combination incorporating an alarm switch<br />
December 2009<br />
002050 P/N10102770P1<br />
December 2009<br />
Security Cert.<br />
Rating No.<br />
1 976a/01<br />
1 976a/02<br />
1 976a/03<br />
1 976a/04<br />
Notes:<br />
1. The Supra key safes are approved when mounted directly to masonry walls in accordance with the instructions noted in the above<br />
table. The approval does not cover the key safes when mounted to alternative substrates or via intermediate substrates such as<br />
plasterboard.<br />
510 20 Nov 2011
PART 4: SECTION 18<br />
SECURITY GLAZING<br />
This <strong>section</strong> includes security glazing that has been approved to one or more of the following standards:<br />
LPS 1270: Issue 1 Requirements and testing procedures for the LPCB approval and listing of intruder<br />
resistant security glazing units<br />
BS EN 356: 2000 Glass in Building - Security Glazing - Testing and classification of resistance against<br />
manual attack<br />
BS EN 1063: 2000 Glass in building. Security glazing. Testing and classification of resistance against<br />
bullet attack.<br />
LPS 1270 was developed because it was considered the method for classifying the attack resistance of<br />
security glazing specified within the current European standard (BS EN 356: 2000) was incompatible with that<br />
employed within LPS 1175: Issue 7 Requirements and testing procedures for the LPCB approval and listing of<br />
intruder resistant building components, strongpoints, security enclosures and free-standing barriers. This was<br />
because:<br />
BS EN 356: 2000 does not classify glass according to its resistance to different levels of attack based on<br />
the tools and time available to an intruder.<br />
The tests contained within BS EN 356: 2000 do not evaluate the glass’s susceptibility to attacks involving<br />
the creation of small holes through which locking hardware may be manipulated and/or protected items,<br />
such as items on display within shop windows or display cases, may be removed.<br />
Glazing materials rated to BS EN 356: 2000 that have previously been included within products and<br />
systems submitted for testing to LPS 1175: Issue 7 has undermined those product’s/system’s ability to<br />
offer intruder resistance commensurate with the security ratings sought to LPS 1175: Issue 7.<br />
The LPS 1270 classification system contains three digits. Each digit describes the glazing’s resistance to<br />
creation of a different size of hole, as described in the table below.<br />
Digit Type Tests block<br />
1 Local<br />
penetration<br />
3 Complete<br />
access<br />
8 mm (+3 mm/-0 mm) by<br />
25 mm (+3 mm/-0 mm)<br />
rectangular <strong>section</strong><br />
2 Hand hole 60 mm (+3 mm/-0 mm)<br />
diameter<br />
Elliptical <strong>section</strong> of 400 mm<br />
(+3 mm/-0 mm) major axis<br />
by 225 mm (+3 mm/-0 mm)<br />
minor axis<br />
Notes<br />
Represents the glazing’s likely resistance to creation of a<br />
hole through which a piece of wire, screwdriver, lever or<br />
other such device can be passed. Such an attack may be<br />
attempted by an intruder wishing to operate a panic bar,<br />
emergency lever handle or other non-deadlocked device<br />
capable of releasing the boltwork on the item in which the<br />
glazing is mounted or on an item directly adjacent to that<br />
in which the glazing is mounted.<br />
Represents the glazing’s likely resistance to creation of a<br />
hand hole. Such an attack may be attempted by an<br />
intruder wishing to:<br />
• Operate a thumbturn to release the boltwork on the<br />
item in which the glazing is mounted or on an item<br />
directly adjacent to that in which the glazing is<br />
mounted.<br />
• Retrieve an item from the protected side of the glass,<br />
e.g. an item on display behind a shop window, a set of<br />
door keys or a set of car keys.<br />
This reflects the size of aperture specified in LPS 1175:<br />
Issue 7. The digit confirms the glazing’s resistance to<br />
creation of a hole through which an elliptical test block<br />
measuring 400 mm by 225 mm may be passed. This<br />
replicates the size a person may be able to pass through<br />
and reflects the test block defined in LPS 1175: Issue 7.<br />
The glazing’s resistance to creation of each size of hole will be indicated by a number (security rating) 0 to 8.<br />
The tools and time that the glazing must resist in order to achieve the security ratings match those that<br />
products classified in accordance with LPS 1175: Issue 7 must resist. The only difference is that glazing may<br />
20 Nov 2011 511
PART 4: SECTION 18<br />
SECURITY GLAZING<br />
also achieve a ‘0’ rating in the first and second digits. Such a rating indicates the glazing’s resistance to the<br />
creation of those sizes of hole falls below that required to achieve security rating 1.<br />
The security ratings are loosely based upon domestic risks (security ratings 1 and 2), commercial risks (security<br />
ratings 2, 3 and 4), high security risks (security ratings 5 and 6) and extremely high security facilities (security<br />
ratings 7 and 8).<br />
In order to be classified to LPS 1270, glazing units must achieve a security rating of at least “001”.<br />
When selecting security glazing units it is important to consider other aspects of the product (e.g. window,<br />
doorset or curtain walling system) into which the glazing unit is to be fitted. In <strong>part</strong>icular, it is important to<br />
consider the method by which the glazing unit is held in place. Manufacturers and specifiers should therefore<br />
ensure the complete product or system is assessed and classified in accordance with LPS 1175: Issue 7<br />
rather than simply the glazing.<br />
Essex Safety Glass Limited<br />
Units 1-3, Moss Road, Witham, Essex CM8 3UG, United Kingdom<br />
Tel: +44 (0)1376 520061 • Fax: +44 (0)1376 521176<br />
E-mail: sales@esguk.co.uk • Website: www.esguk.co.uk<br />
Certificate No: 997a to LPS 1270: Issue 1<br />
Laminated Security Glazing<br />
Product Name Type Nominal Total Thickness<br />
(mm)<br />
Nominal Weight<br />
(kg/m 2<br />
Security<br />
Rating<br />
Cert.<br />
No.<br />
ESG Secure LPS Laminated single glazing<br />
13 26.6 001 997a/01<br />
001/13<br />
unit 1, 2, 3, 4<br />
ESG Secure LPS Laminated single glazing<br />
17 28.8 112 997a/02<br />
112/17<br />
unit 1, 2, 4, 5<br />
ESG Secure LPS Laminated single glazing<br />
19 31.2 123 997a/03<br />
123/19<br />
unit 1, 2, 4, 5<br />
ESG Secure LPS Laminated single glazing<br />
23 36 123 997a/04<br />
123/23<br />
unit 1, 2, 4, 5<br />
ESG Secure LPS Laminated single glazing<br />
31 50.1 223 997a/05<br />
223/31<br />
unit 1, 2, 3, 4<br />
ESG Secure LPS Laminated single glazing<br />
40 6<strong>2.2</strong> 224 997a/06<br />
224/40<br />
unit 1, 2, 3, 4<br />
ESG Secure LPS Laminated single glazing<br />
234/44<br />
ESG Secure LPS<br />
235/57<br />
1, 2, 4, 5 44 59.2 234 997a/07<br />
Laminated single glazing<br />
57.5 90 235 997a/08<br />
unit 1, 2, 3, 4<br />
Notes:<br />
1. The number within the product code indicating the thickness will be greater than that noted if thicker layers are used than those noted<br />
for the standard glazing units listed.<br />
2. The 4 mm toughened glass layer on the attack face of the glazing unit may be replaced by 4 mm float glass, 4 mm heat strengthened<br />
glass, 4 mm ‘ESG Pyrotech’ glass or 6 mm ‘ESG Pyrotech’ glass. However, these options may affect the nominal thickness and<br />
weight noted for this ‘ESG Secure’ glazing unit.<br />
3. The 4 mm float glass layer on the non-attack face of the glazing unit may be replaced by thicker float glass up to 19 mm, toughened<br />
glass between 4 mm and 19 mm thick, heat strengthened glass between 4 mm and 19 mm thick, 4 mm ‘ESG Pyrotech’ glass or 6 mm<br />
‘ESG Pyrotech’ glass. However, these options may affect the nominal thickness and weight noted for this ‘ESG Secure’ glazing unit.<br />
4. As an alternative to the single glazing units, Essex Safety Glass Limited also supply double glazed units (DGUs) formed using the<br />
glazing units approved to LPS 1270. The DGU’s are formed by adding a layer of float glass, toughened glass, heat strengthened<br />
glass or ‘ESG Pyrotech’ glass to the non-attack face. These are separated from the glazing units listed above by a spacer between 6<br />
mm and 22 mm thick. The DGUs are therefore thicker and heavier than the ‘ESG Secure’ single glazing units listed above. The<br />
product codes for ‘ESG Secure’ DGUs include the letters DGU immediately before the unit’s total thickness. For example, the ‘001/11’<br />
unit with a 6 mm spacer and 4 mm toughened glass on the non-attack side of the DGU would have a code ‘001/DGU21’.<br />
5. The 4 mm toughened glass layer on the non-attack face of the glazing unit may be replaced by thicker toughened glass up to 19 mm,<br />
float glass between 4 mm and 19 mm thick, heat strengthened glass between 4 mm and 19 mm thick, 4 mm ‘ESG Pyrotech’ glass or<br />
6 mm ‘ESG Pyrotech’ glass. However, these options may affect the nominal thickness and weight noted for this ‘ESG Secure’ glazing<br />
unit.<br />
512 20 Nov 2011
Part<br />
5<br />
CONSTRUCTION<br />
PRODUCTS
PART 5: CONSTRUCTION PRODUCTS<br />
INTRODUCTION<br />
The products listed in this <strong>part</strong> of the Red Book have been assessed for ‘Technical Approval’ (or Certification)<br />
based on the intended use of the product, and take into account the UK Building Regulations, Highways<br />
Regulations, the Essential Requirements from the Construction Products Directive (CPD) and other directives<br />
as necessary.<br />
Most of the approvals listed are for products and systems for which there are no directly applicable recognised<br />
standards and a Technical Approval certification has been granted. Where British, European or other<br />
recognised standards apply, we also approve products against these standards.<br />
The granting of certification depends on the type testing and initial factory assessments meeting the relevant<br />
standards and scheme requirements laid down. Certification is maintained by regular factory production<br />
control surveillance visits and, where specified, the testing of audit samples to ensure that the product<br />
continues to be made in exactly the same way.<br />
IMPORTANT<br />
We are currently changing the way that we approve and certificate products with the result that we will not be<br />
issuing any new Technical Approvals. In the future, new certificates will issued against published BRE<br />
Schemes and, where appropriate BRE Product Standards (BPS). Details of current Schemes and associated<br />
BPSs can be found at: www.<strong>RedBookLive</strong>.com<br />
This does not affect the validity of the current Technical Approvals listed in this <strong>section</strong>. These will<br />
remain valid for three years from their date of issue - or until converted into one of our new range of<br />
Approved Building Product certificates.<br />
514 20 Nov 2011
PART 5: SECTION 1<br />
ANCHORS, CONNECTORS, FASTENERS AND FIXING SYSTEMS<br />
The scope of products approved under this <strong>section</strong> is as follows:<br />
Anchors, connectors, fasteners and fixing components and systems manufactured from metals and plastics<br />
for providing mechanical jointing between components, or to fix to substrates of concrete, masonry, metal,<br />
timber and plastics, for building and construction products and kits over a specified design life.<br />
Max Frank Limited<br />
Whittle Road, Meir, Stoke-on-Trent, Staffordshire ST3 7HF, United Kingdom<br />
Tel: +44 (0)1782 598041 • Fax: +44 (0)1782 315056<br />
E-mail: info@maxfrank.co.uk • Website: www.maxfrank.co.uk<br />
Certificate No: 136/07 Rev Oct 10<br />
Certificated Products<br />
Shearail punching shear<br />
reinforcement<br />
Shearail punching shear reinforcement has been assessed to confirm its suitability, within<br />
limitations, for use as a punching shear reinforcement in reinforced concrete floor and<br />
roof slabs in buildings. The product comprises a set of forged steel studs (smooth or<br />
ribbed) connected at one end to a steel rail which is used to position them in the<br />
construction prior to placement of structural concrete. The product is available in a range<br />
of stud sizes. Studs are welded to the rails at predetermined spacing. Shearails are<br />
produced to meet specific project requirements. The minimum number of studs on a rail<br />
is two.<br />
Cert. No.<br />
136/07<br />
Rev Oct<br />
10<br />
20 Nov 2011 515
PART 5: SECTION 2<br />
DRAINAGE AND PLUMBING SYSTEMS<br />
The scope of products approved under this <strong>section</strong> is as follows:<br />
Drainage and plumbing products, systems and kits for domestic, commercial and industrial building<br />
applications manufactured from clay and cementitious based materials, plastics, metals and composites to<br />
provide for transfer and containment of potable and foul water, rainwater, sewage and effluent over a<br />
specified design life.<br />
516 20 Nov 2011
PART 5: SECTION 3<br />
FLOORING SYSTEMS<br />
The scope of products approved under this <strong>section</strong> is as follows:<br />
Flooring products, systems and kits for floor bases and floor finishes for domestic, commercial and industrial<br />
building applications manufactured from gypsum, clay and cementitious based materials, plastics, timber,<br />
metals and composites to provide support for loading, decoration and thermal, acoustic and fire protection<br />
over a specified design life.<br />
Intelligent Engineering (UK) Ltd<br />
Shire House, West Common, Gerrards Cross, Slough, Bucks SL9 7QN, United Kingdom<br />
Tel: +44 (0) 1753 890 575 • Fax: +44 (0) 1753 899 056<br />
E-mail: turner@ie-sps.com • Website: www.ie-sps.com<br />
Certificate No: ABP008 to BPS7007<br />
Certificated Products<br />
Flooring System -<br />
permanent and temporary<br />
stadium risers<br />
SPS Terraces are individual step units which are joined together one above the other in<br />
sets of four to form terraces. Each step unit consists of a horizontal sandwich panel<br />
(4mm steel faceplates with a 20mm high density (≥1000kg/m 3 ) polyurethane core)<br />
welded to steel plate risers. Connections between individual step units are made with<br />
proprietary fasteners which are also used to fix steel bracing and closing plates to<br />
completed terraces.<br />
SPS Terraces are available with a horizontal step width of 830mm and riser heights of<br />
178mm (7”) and 365mm (14”). Terraces consisting of four step units having a maximum<br />
length of 10m are supported on a braced steel perimeter frame. A steel closing plate is<br />
fixed immediately beneath the risers angled to the rake of the terrace.<br />
Cert. No.<br />
ABP008<br />
<br />
<br />
Steel is specified as S235 in accordance with BS EN 10025 Hot rolled products of<br />
structural steels.<br />
The polyurethane core is produced from polyol and isocyanate<br />
Fire resistance is achieved by the addition of fire protection using stone mineral wool<br />
insulation board (see table 3) fixed beneath the completed terraces.<br />
SPS Terraces are intended for use in permanent and temporary grandstand structures in<br />
the UK. The individual step units are connected together to form terraces in such a way<br />
that they can be dismantled and reassembled at another location.<br />
Certificate No: 154/11<br />
Certificated Products<br />
SPS Bubble Core Floors<br />
SPS (Sandwich Plate System) Bubble Core Floors are built up from a number of<br />
individual SPS Plates laid side by side and fixed to supporting steel located under each<br />
longitudinal joint in the direction of span. SPS Plates are of sandwich construction and<br />
comprise upper and lower steel plates bonded to a voided polyurethane elastomer core.<br />
Voids in the core are formed by the inclusion of hollow polypropylene spheres (nominal<br />
50mm diameter). The structural performance of the SPS Bubble Core Floor is achieved<br />
by the composite action of the SPS Plates and the supporting steel beams. SPS Plate<br />
units are a maximum of 3m wide by 9m long.<br />
This certificate reports on the outcome of specified tests on defined construction<br />
configurations. It provides design data relating to that construction for use by structural<br />
engineers competent in the design of steel structures.<br />
The tested construction incorporated three 9m x 3m SPS Plates assembled to form a 9m<br />
x 9m floor supported on a perimeter framework of rolled steel <strong>section</strong>s with proprietary<br />
fabricated steel beams providing intermediate support at plate junctions (see Figure 1).<br />
The SPS Plates were each 60mm thick, having a 50mm core sandwiched between two<br />
5mm steel plates.<br />
Fire protection shall be provided by means of stone mineral wool insulation board fixed<br />
immediately beneath the SPS Plates and supporting steel beam construction.<br />
The laboratory airborne and impact (acoustic) performance of the system has been<br />
determined for a number of different configurations.<br />
Cert. No.<br />
154/11<br />
20 Nov 2011 517
PART 5: SECTION 3<br />
FLOORING SYSTEMS<br />
Certificated Products<br />
Cert. No.<br />
The characteristics of the product and its method of application have been reviewed with<br />
respect to the current Building Regulations, British and European Standards and other<br />
publications in the United Kingdom in February 2010.<br />
518 20 Nov 2011
PART 5: SECTION 4<br />
GROUNDWORKS AND FOUNDATION SYSTEMS<br />
The scope of products approved under this <strong>section</strong> is as follows:<br />
Groundworks and foundation products, systems and kits for domestic, commercial and industrial building<br />
applications manufactured from clay and cementitious based materials, plastics, timber, metals and<br />
composites to provide support for loading, water and gas resistance and thermal and fire protection over a<br />
specified design life.<br />
Cordek Limited<br />
Spring Copse Business Park, Slinfold, West Sussex RH13 0SZ, United Kingdom<br />
Tel: +44 (0)1403 799600 • Fax: +44 (0)1403 791718<br />
E-mail: sales@cordek.com • Website: www.cordek.com<br />
Certificate No: 031/96<br />
Certificated Products<br />
Ventform Panels<br />
Ventform panels have been assessed to confirm their suitability for use as a ventilation<br />
void former for the support of cast in-situ concrete slabs for either suspended or ground<br />
supported floors and to facilitate ventilation of hazardous gases. Ventform panels also<br />
provide insulation to improve thermal performance of ground floor construction.<br />
Cert. No.<br />
031/96<br />
Saint-Gobain Weber Limited<br />
Dickens House, Enterprise Way, Flitwick, Beds MK45 5BY, United Kingdom<br />
Tel: +44 (0) 1525 722101 • Fax: +44 (0) 1525 718988<br />
E-mail: mick.lovell@netweber.co.uk • Website: www.netweber.co.uk<br />
Certificate No: 052/98<br />
Certificated Products<br />
Weber Leca Insulation Fill<br />
Weber Leca Insulation Fill has been assessed to confirm its suitability, within limitations,<br />
for use as an insulation and hardcore material below ground floors. The product is a<br />
graded lightweight expanded clay aggregate. In a construction it is overlaid with a<br />
specified waterproofing membrane and stabilising wire mesh layer (both items not<br />
covered by this certificate).<br />
Cert. No.<br />
052/98<br />
20 Nov 2011 519
PART 5: SECTION 5<br />
MEMBRANES<br />
The scope of products approved under this <strong>section</strong> is as follows:<br />
Membranes for buildings manufactured from polymers, bitumen, rubbers and metal foil in liquid applied or<br />
sheet form for use as continuous or discontinuous layers for the control of the movement of air, liquid water,<br />
water vapour, carbon dioxide, radon and methane through floor, wall, roof and internal elements of buildings<br />
and structures over a specified design life.<br />
DuPont de Nemours (Luxembourg) S.a.r.l.<br />
Rue General Patton, L-2984, , Luxembourg<br />
Tel: +352 3666 5736<br />
E-mail: jimmy.helfenstein@lux.dupont.com • Website: www.tyvek.co.uk<br />
Certificate No: 155/10<br />
Certificated Products<br />
Tyvek® UV Facade<br />
Underlay 2524B<br />
Tyvek® UV Facade Underlay 2524B is intended to be used in Façade construction as a<br />
secondary, water vapour permeable, weather resistant layer, for protection against wind<br />
driven rain or snow and the ingress of dust. It has been designed for use with open or<br />
ventilated cladding constructions.<br />
Tyvek® UV Facade 2524B is a UV and heat stabilised Type LR low resistance<br />
(breathable) polymeric underlay as defined in BS 5250 Code of practice for the control of<br />
condensation in buildings. It comprises a 2 layer laminate of high density polyethylene,<br />
and a polypropylene fleece. Tyvek® UV Facade 2524B is embossed black on the outer<br />
surface (as installed) and white on the inner surface.<br />
Cert. No.<br />
155/10<br />
Industrial Textiles & Plastics Ltd<br />
Stillington Road, Easingwold, York YO61 3FA, United Kingdom<br />
Tel: +44 (0)1347 825200 • Fax: +44 (0)1347 825222<br />
E-mail: info@itpltd.com • Website: www.itpltd.com<br />
Certificate No: 095/02<br />
Certificated Products<br />
Powerbase MB 420 Gas<br />
Resistant Membrane<br />
Powerbase MB 420 has been assessed to confirm its suitability for use as a gas and<br />
moisture resistant barrier for incorporation into the floor of a building to restrict the<br />
ingress of radon, methane and carbon dioxide from the ground in situations where there<br />
is a risk of contamination to the internal environment of the building.<br />
Cert. No.<br />
095/02<br />
Certificate No: 124/07<br />
Certificated Products<br />
Powerlon UltraPerm<br />
Breather Membrane<br />
Powerlon UltraPerm Breather Membrane (Powerlon UltraPerm BM) has been assessed<br />
to determine that it can be used, with conditions, as a roof underlay for use in pitched<br />
warm and cold roof constructions with or without ventilators, as a secondary weather<br />
resistant layer, for protection against wind driven rain and snow, tile wind-uplift, and<br />
ingress of dust to satisfy or contribute towards satisfying the requirements of the Building<br />
Regulations within the United Kingdom and Ireland. Powerlon UltraPerm BM consists of<br />
a water resistant and breathable polypropylene film sandwiched between two<br />
polypropylene spunbonded layers and is a permeable low vapour resistance (type LR)<br />
roof underlay as defined by BS 5250 Code of practice for the control of condensation in<br />
buildings. It is available in different weights, between 85g/m 2 and 140g/m 2 .<br />
Cert. No.<br />
124/07<br />
520 20 Nov 2011
PART 5: SECTION 5<br />
MEMBRANES<br />
Klober Limited<br />
Unit 6F, East Midlands Distribution Centre, Short Land, Castle Donington, Derbyshire DE74 2HA, United<br />
Kingdom<br />
Tel: +44 (0)1332 813050 • Fax: +44 (0)1332 814033<br />
Certificate No: 105/03<br />
Certificated Products<br />
Sepa® forte<br />
Sepa ® forte is a reinforced multi-layer membrane and is blue in colour on the upper side.<br />
It is suitable, within conditions, as a roof underlay for use in pitched roof construction,<br />
under slates or tiles as a secondary weather resistant layer, for protection against winddriven<br />
rain and snow, tile wind-uplift and ingress of dust. The underlay has good<br />
resistance to tearing during installation and remains flexible at low temperatures.<br />
Cert. No.<br />
105/03<br />
Certificate No: ABP013 to BPS 7005 Issue 1.0<br />
Certificated Products<br />
Sepa Light<br />
Sepa Light is a UV and heat stabilised Type HR polymeric roof underlay. It comprises a<br />
polypropylene non-woven layer which is coated on one surface with a continuous film of<br />
polyethylene/polypropylene blend and is regarded as a high water vapour resistance<br />
(Type HR) underlay as defined in BS 5250 Code of practice for the control of<br />
condensation in buildings . Sepa Light is manufactured in rolls as shown below.<br />
Cert. No.<br />
ABP013<br />
Product dimensions CharacteristicNominal value Roll length 25 and 50 m Roll<br />
width1.0, and 1.5 m<br />
Sepa Light is dark grey with the brand name and unique production code printed on the<br />
upper surface (as installed) and blank on the lower surface.<br />
Sepa Light is intended to be used in pitched roofs as a secondary, impermeable, weather<br />
resistant layer, for protection against wind driven rain or snow and the ingress of dust. It<br />
is installed beneath roof tiles or slates in roofs constructed in accordance with BS 5534<br />
Code of practice for slating and tiling (including shingles).<br />
Visqueen Building Products<br />
Maerdy Industrial Estate, Rhymney, Tredegar NP22 5PY, United Kingdom<br />
Tel: +44 (0)1685 840672 • Fax: +44(0)1685 842580<br />
E-mail: enquiries@visqueenbuilding.co.uk • Website: www.visqueenbuilding.co.uk<br />
Certificate No: 083/01<br />
Certificated Products<br />
Visqueen Radon<br />
Membrane<br />
Visqueen Radon Membrane polyethylene sheet membrane has been assessed to<br />
confirm its suitability for use as <strong>part</strong> of a radon gas and moisture-resistant system for<br />
incorporation into the floor of a building in situations where there is a risk of<br />
contamination to the internal environment of the building arising from radon evolution<br />
from the ground.<br />
Cert. No.<br />
083/01<br />
Certificate No: 112/04<br />
Certificated Products<br />
Visqueen Eco-membrane<br />
Visqueen Eco-membrane re-cycled low density polyethene sheet membrane has been<br />
assessed to confirm its suitability for use as a damp proof membrane for incorporation<br />
into the floor of a building in situations where there is a risk of damage to the internal<br />
environment of the building arising from moisture from the ground.<br />
Cert. No.<br />
112/04<br />
20 Nov 2011 521
PART 5: SECTION 6<br />
PRE-FABRICATED BUILDING SYSTEMS<br />
The scope of products approved under this <strong>section</strong> is as follows:<br />
Building systems and kits of superstructure, basement and roofing structure for buildings as products,<br />
components and systems of wall, floor, roof and stairways, linings and finishes manufactured from gypsum,<br />
clay and cementitious based materials, plastics, timber, metals and composites for domestic and commercial<br />
applications over a specified design life.<br />
Kingspan Limited (t/a Profiles and Sections)<br />
Sherburn, Malton, North Yorkshire YO17 8PQ, United Kingdom<br />
Tel: +44 (0)1944 712000 • Fax: +44 (0)1944 710555<br />
E-mail: enquiries@kingspanprofiles.com • Website: www.kingspanprofiles.com<br />
Certificate No: 118/06<br />
Certificated Products<br />
Kingframe Building and<br />
Architectural Façade<br />
System<br />
The Kingframe Building and Architectural Façade Systems have been assessed to<br />
confirm suitability for use as building structures (KBS) and as infill construction to form<br />
external facades to steel or concrete framed single and multi storey buildings (AFS).<br />
The Kingframe Building System (KBS) comprises; load-bearing steel stud external wall<br />
frames incorporating specified insulation, load-bearing and non load-bearing internal wall<br />
frames incorporating specified insulation, steel and timber cassette floor panels,<br />
composite concrete floors and steel and timber cassette roof panels.<br />
The Architectural Façade System (AFS) comprises; non load-bearing steel stud wall<br />
frames incorporating specified insulation.<br />
The characteristics of the systems covered by this certificate are:<br />
Cert. No.<br />
118/06<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Structure<br />
Behaviour in relation to fire<br />
Weathertightness<br />
Thermal transmittance and condensation risk<br />
Acoustic performance<br />
Durability<br />
Factory production and quality control<br />
Practicality of site installation<br />
The KBS and AFS systems are installed by Kingspan Ltd trained and approved installers.<br />
The KBS and AFS systems have been assessed for use with masonry, render, brick slip,<br />
rainscreen, timber and stone claddings (outside the scope of this certificate) which are<br />
not supplied by Kingspan Ltd but for which performance assessments have been made<br />
in relation to use with the KBS and AFS systems.<br />
The characteristics of The Kingframe Building and Architectural Façade Systems have<br />
been reviewed with respect to the current Building Regulations, British and European<br />
Standards and other publications in the United Kingdom and Ireland in January 2011.<br />
Metsec Limited<br />
Broadwell Road, Oldbury, West Midlands B69 4HE, United Kingdom<br />
Tel: +44 (0)121 601 6000 • Fax: +44 (0)121 601 6126<br />
E-mail: metsecframing@metsec.com • Website: www.metsec.com<br />
Certificate No: 110/04<br />
Certificated Products<br />
Metframe and SFS Building<br />
System<br />
The Metframe and SFS Building Systems have been assessed to confirm suitability,<br />
subject to the limitations of this certificate, for use in the construction of residential and<br />
commercial buildings in the UK with a floor no more than 18m from the ground unless<br />
Cert. No.<br />
110/04<br />
522 20 Nov 2011
Certificated Products<br />
otherwise stated in this certificate<br />
PART 5: SECTION 6<br />
PRE-FABRICATED BUILDING SYSTEMS<br />
Cert. No.<br />
The loadbearing system either arrives on site in pre-made panels (Metframe) where<br />
connections are predominately bolted or is ‘stick-built’ on site (SFS) with connections<br />
predominately screw fixed. The non-loadbearing system (SFS) is ‘stick-built’ on site using<br />
screw fixed connections and is used to form non-loadbearing external walls in traditional<br />
superstructures.<br />
The Metframe and SFS Building Systems included within the scope<br />
of this certificate are listed below along with the materials or<br />
products (outside the scope of this certificate) for which the<br />
performance of the Metframe and SFS building systems have been<br />
assessed in typical building applications.<br />
Intermediate/separating floors:<br />
Cold formed galvanised steel Z-purlins<br />
Profiled metal decking to support in-situ poured concrete*<br />
Under cladding with 80mm Isowool 1000 insulation*<br />
Two 12.5mm layers of British Gypsum Fireline Board*<br />
Either over cladding with 5mm Ethafoam and 50mm<br />
concrete screed or<br />
Isolgomma R10 and 19mm Viroc board*.<br />
Cold-formed galvanised steel joists<br />
75mm Isowool 1605 located between the joists*<br />
Under cladding with defined combinations of British Gypsum Wall and Fireline<br />
Boards*<br />
External wall panels (load bearing and non-load bearing):<br />
Cold-formed galvanised steel stud (SFS) and pre-fabricated panels (Metframe)<br />
Defined combinations of British Gypsum lining boards, cement <strong>part</strong>icle board<br />
and Thermawall TW55 insulation board*<br />
Isowool Hitherm insulation between the studs. The panels form the inner leaf<br />
of a wall having a 50mm cavity*<br />
Outer leaf of conventional masonry construction*<br />
External wall panels (load bearing and non-load bearing):<br />
Cold-formed galvanised steel stud (SFS) and pre-fabricated panels (Metframe)<br />
Defined combinations of British Gypsum lining boards, cement <strong>part</strong>icle board<br />
and Thermawall TW55 insulation board*<br />
Isowool Hitherm insulation between the studs. The panels form the inner leaf<br />
of a wall having a 50mm cavity*<br />
Outer leaf of conventional masonry construction*<br />
Internal wall panels (load bearing and non-load bearing):<br />
Cold-formed galvanised steel stud panels<br />
Defined combinations of British Gypsum lining boards*.<br />
Isowool 1000, 1200 and 1605 insulation between the studs*.<br />
* Materials/products supplied by others and outside the scope of this certificate<br />
The Metframe and SFS Building Systems which are designed on a site and project<br />
specific basis, are used with other building elements and products, that are supplied by<br />
others, to deliver specific building requirements. The design verification shall be carried<br />
out by a suitably qualified and experienced Metsec plc engineer and comply with relevant<br />
structural regulations, codes and standards in force in the UK at that time and including<br />
the Metsec plc Technical Manual. The structural adequacy of the Metframe and SFS<br />
Building Systems, including connection and foundation design, have not been assessed<br />
by BRE Certification as the design verification will be site and project specific.<br />
The characteristics of the system elements covered by this certificate are:<br />
Behaviour in relation to fire<br />
Weathertightness<br />
Thermal transmittance and condensation risk<br />
Acoustic performance<br />
Durability<br />
Factory production and quality control<br />
Practicality of site installation (with reference to Metsec plc Technical Manual).<br />
The structural adequacy of the Metframe and SFS building systems, including foundation<br />
design, has not been assessed by BRE Certification.<br />
The Metframe and SFS Building Systems are installed by Metsec plc Approved Installers.<br />
20 Nov 2011 523
PART 5: SECTION 6<br />
PRE-FABRICATED BUILDING SYSTEMS<br />
Certificated Products<br />
Cert. No.<br />
The performance of the system depends on the quality of its installation. Whilst the<br />
installation manual has been examined by BRE Certification and a site installation<br />
observed to confirm that the system can be assembled satisfactorily following those<br />
installation instructions, the actual quality of installation achieved on specific sites is not<br />
covered by this certificate. The systems shall be installed by appropriately trained and<br />
experienced Metsec plc Approved Installers.<br />
When used as <strong>part</strong> of the external wall construction to framed superstructures (i.e.Timber<br />
BS 5268 Structural use of timber; Masonry BS 5628 Code of practice for the use of<br />
masonry, Steel BS 5950 Structural use of steelwork in building; Concrete BS 8110<br />
Structural use of concrete with a masonry external surface (i.e. BS EN 771-1:2003<br />
Specification for masonry units. Clay masonry units or previously BS 3921 Specification<br />
for clay bricks) the non-loadbearing SFS system may be used in buildings with a floor<br />
more than 18 metres from the ground.<br />
The load bearing site-built stick system (SFS) shall not be used for constructions over 3<br />
storeys in height.<br />
Characteristics of the Metframe and SFS Building Systems have been reviewed with<br />
respect to the current Building Regulations, British and European Standards and other<br />
publications in the United Kingdom in April 2010.The assessment is described in the<br />
following pages, which form integral <strong>part</strong>s of this certificate and should be read in their<br />
entirety.<br />
524 20 Nov 2011
PART 5: SECTION 7<br />
BUILDING SYSTEMS FOR DWELLINGS<br />
BRE Global has developed the BPS 2020 suite of standards to provide for approval of building systems for<br />
dwellings. The primary objective of this approval scheme is to encourage innovation whilst maintaining<br />
acceptable levels of safety and to create confidence in the development and use of building systems for<br />
dwellings, <strong>part</strong>icularly those using Modern Methods of Construction (MMC).<br />
Fusion Building Systems<br />
Fusion House, Scirocco Close, Moulton Park, Northamptonshire NN6 3HE, United Kingdom<br />
Tel: +44 (0)1604 490540 • Fax: +44 (0)1604 490549<br />
E-mail: Tom.Salvesen@fusionbuild.com • Website: www.fusionbuild.com<br />
Certificate No: ABP006 to BPS2020<br />
Certificated Products<br />
Fusion Building System<br />
The Fusion building system is a panelised light gauge steel building system for the<br />
construction of dwellings up to 6 storeys in height, and as the upper six storeys of a<br />
building which has a top floor height not more than 30m above ground level. In buildings<br />
with a traditional pitched roof no floor shall be more than 18m above ground level. The<br />
system comprises the following principal building elements.<br />
External Walls - the inner leaf of external walls consists of factory made loadbearing cold<br />
rolled light gauge steel <strong>section</strong>s with flame retardant expanded polystyrene insulation<br />
moulded into the body of the panel and forming an external layer to provide a hybrid<br />
construction. The Fusion building system has been assessed for use with conventional<br />
masonry cladding and specified internal plasterboard lining.<br />
Internal Walls - load bearing walls are formed using cold rolled light steel panels as<br />
described for external walls. Separating walls consist of two load bearing panels<br />
separated by a cavity with gable apex panels used in pitched roofs.<br />
Floors - upper floors are either of factory built cassette form using C <strong>section</strong> steel joists<br />
and steel channel rim <strong>section</strong>s covered with oriented strand board or site assembled,<br />
using C <strong>section</strong> steel joists supported at the ends by steel Z <strong>section</strong>s and covered with<br />
oriented strand board. Separating floors are designed as com<strong>part</strong>ment floors and<br />
incorporate additional proprietary material to provide fire resistance and acoustic<br />
performance. Composite concrete/steel deck floors have also been assessed for use with<br />
the Fusion building system.<br />
Roofs - flat roofs are of factory built floor cassette form (as floors) suitable to support<br />
proprietary warm deck roof systems or traditional proprietary timber trussed rafter roofs.<br />
Cert. No.<br />
ABP006<br />
Key Housing Limited<br />
2 Sebastian Street, London EC1V 0HE, United Kingdom<br />
Tel: +44 (0)20 7687 6004 • Fax: +44 (0)20 7687 6002<br />
E-mail: kahn@key-housing.co.uk • Website: ww.key-housing.co.uk<br />
Certificate No: ABP 010 to BPS 2020<br />
Certificated Products<br />
Key Housing Building<br />
System<br />
The Key Housing building system is a volumetric steel framed building system for the<br />
construction of dwellings up to 6 storeys in height with floors up to 18m above ground<br />
level. The system comprises the following principal building elements.<br />
External Walls - Factory made insulated loadbearing volumetric building pods forming the<br />
inner leaf of external walls assembled from a combination of hot and cold rolled light steel<br />
C <strong>section</strong>s, (of various material thickness up to 3mm) with mineral fibre insulation. An<br />
internal lining of one or more layers calcium silicate board is added to provide the<br />
required period of fire resistance and a surface finish. External faces are lined with fibre<br />
cement boards. The volumetric modules incorporate brackets allowing steel wall ties to<br />
be fitted on site to tie external cladding systems to the Key Housing external wall panel.<br />
Cert. No.<br />
ABP 010<br />
20 Nov 2011 525
PART 5: SECTION 7<br />
BUILDING SYSTEMS FOR DWELLINGS<br />
Certificated Products<br />
The backing wall does not rely on the exterior cladding to provide water resistance and<br />
has been designed to accommodate a number of cladding systems. BRE report 267-819<br />
provides information on the use of typical insulated render, brick skin and terracotta tile<br />
rainscreen applications which are outside the scope of the certificate.<br />
Internal Walls - load bearing walls are formed using cold rolled steel C <strong>section</strong>s.<br />
Separating walls incorporate a cavity and are formed by placing two steel C <strong>section</strong><br />
panels adjacent to one another. Walls incorporate mineral fibre insulation and are lined<br />
on room faces with calcium silicate board.<br />
Floors - Upper floors are of factory built volumetric pod construction, the floor surface<br />
and supporting steel joists are <strong>part</strong> of the upper pod and the ceiling below is formed by<br />
the lower pod. Separating floors are designed as com<strong>part</strong>ment floors and incorporate<br />
additional proprietary material, including calcium silicate board, to provide fire resistance<br />
and acoustic performance.<br />
Roof - Roof structures are formed by the top of the upper pod, used to form a flat roof<br />
structure (suitable to support a warm deck roof system outside the scope of the<br />
certificate) or a traditional pitched roof (formed of roof trusses with cladding, which is<br />
outside the scope of the certificate).<br />
Cert. No.<br />
SIP Energy Ltd<br />
Athenry, , Co Galway, Ireland<br />
Tel: +353 (0)91 874290 • Fax: +353 (0)91 874295<br />
E-mail: info@sip-energy.com • Website: www@sip-energy.com<br />
Certificate No: ABP 005/001 to BPS2020<br />
Certificated Products<br />
SIP Energy Structurally<br />
Insulated Panel System<br />
The SIP Energy Structurally Insulated Panel System (incorporating structurally insulated<br />
wall and roof panels) is a factory produced structurally insulated panel (SIP) system for<br />
the construction of dwellings up to 3 storeys in height. The system, shown in figures 1 to<br />
5, comprises the following principal building elements;<br />
1.1 External Walls - load bearing factory assembled wall panels comprising timber<br />
studs, OSB facings and extruded polystyrene insulation, bonded together by<br />
polyurethane adhesive. The key components of these panels are:<br />
- 15mm OSB sheathing<br />
- 100mm* internal timber stud framing** with XPS (Extruded Polystyrene) insulation infill<br />
between<br />
- 15mm OSB sheathing<br />
The panels are erected and fixed together on site using power driven 2.8mm by 63mm<br />
ringshank nails and screws. Preservative treated timber plates, bolted to the<br />
substructure, are used for accurate positioning and levelling. Panels interlock with<br />
adjacent panels and with location plates to provide a positive connection which is also<br />
sealed by application of sealant during installation. The walls have a breather membrane<br />
and conventional masonry cladding (provided by others) externally with a 50mm drained<br />
and vented cavity. Any other external cladding is outside the scope of this certificate. An<br />
internal lining of plasterboard is added (by others) to provide the required period of fire<br />
resistance and a surface finish.<br />
* Panels with thicker insulation are available<br />
** Preservative treated timber can be used if requested.<br />
1.2 Internal Walls - load bearing walls can be formed using the panels as described for<br />
external walls. Com<strong>part</strong>ment walls between adjacent dwellings consist of two panels<br />
separated by a cavity as shown in Figure 5<br />
1.3 Floors - floors are formed using conventional components such as I <strong>section</strong> joists<br />
with OSB decking. The OSB deck can be carried over the head of wall panels below to<br />
provide a connection to the wall. See figure 1<br />
1.4 Roof - roofs can be formed using similar panels to the walls (with 125mm thickness<br />
insulation infill) or by using conventional roof trusses. When SIP Energy panels are used<br />
they are inclined to provide support to the roof underlay and battens which support the<br />
tile covering. A timber or steel beam (outside the scope of this certificate) is used to<br />
support the roof panels at the ridge. See figure 1<br />
Cert. No.<br />
ABP<br />
005/001<br />
526 20 Nov 2011
PART 5: SECTION 7<br />
BUILDING SYSTEMS FOR DWELLINGS<br />
Certificated Products<br />
Cert. No.<br />
1.5 Other items - Other items typically supplied with the SIP Energy system include<br />
DPCs, mineral wool insulation, cavity barriers, lining boards, acoustic sealant, ceiling<br />
battens, fixing plates, and foam sealant to fill joints. These are not covered by this<br />
certificate.<br />
The innovative elements covered by this certificate are:<br />
- The insulated wall panel which can also be used inclined to form a roof<br />
- Fixing brackets and straps for frame and foundation connections<br />
The non-innovative elements assessed for use with the above innovative elements<br />
- The internal wall and ceiling linings<br />
- Roof insulation applied between roof trusses<br />
- The timber based floor joists and decking<br />
- The masonry external wall cladding<br />
- The tile or slate roof cladding<br />
20 Nov 2011 527
PART 5: SECTION 8<br />
TRUSSED RAFTERS (TIMBER)<br />
This scheme has now been withdrawn.<br />
528 20 Nov 2011
PART 5: SECTION 9<br />
THERMAL INSULATION SYSTEMS<br />
The scope of products covered under this scheme is as follows:<br />
Thermal insulation products, systems and kits, with formed and formless materials, for domestic, commercial<br />
and industrial building applications manufactured from cellulose, mineral and natural fibre, clay and<br />
cementitious based materials, plastics, timber, metals and composites. These provide control of thermal<br />
movement through floor, wall, roof and internal elements of buildings, decoration, and weather resisting, fire<br />
and acoustic protection with and without mechanical and adhesive fixings, with continuous or discontinuous<br />
layers.<br />
Euroform Products Limited<br />
The Heliport, Lyncastle Road, Appleton, Warrington, Cheshire WA44 4SN, United Kingdom<br />
Tel: +44 (0) 1925 860999 • Fax: +44 (0) 1925 860066<br />
E-mail: sales@euroform.co.uk<br />
Certificate No: 147/08<br />
Certificated Products<br />
U Foil 1BD/A-1 Single Foil<br />
Bubble Insulation and U<br />
Foil 1BD/A Double Foil<br />
Bubble Insulation<br />
U Foil 1BD/A-1 (Single) and 1BD/A (Double) Foil Subble Insulation products have been<br />
assessed to confirm their suitability for use as insulation behind internal dry lining or for<br />
improving insulation to external cavity walls on the internal side of the weathering<br />
protection as <strong>part</strong>ial fill cavity wall insulation for buildings with masonry or dense concrete<br />
walls. The products consist of aluminium foil faced polyethylene bubble film multilayer<br />
laminates.<br />
Cert. No.<br />
147/08<br />
Certificate No: 148/08<br />
Certificated Products<br />
U Foil VBF Vented Foil<br />
Bubble<br />
U Foil VBF Vented Foil Bubble is a reflective insulation and vapour open cavity rain<br />
barrier and has been assessed to confirm its suitability for use as a thermal isolating<br />
layer for improving insulation to external cavity walls of timber frame construction in the<br />
United Kingdom. The product consists of an aluminium foil faced polyethylene bubble film<br />
laminate. U Foil VBF Vented Foil Bubble is installed against the inner leaf sheathing<br />
withing the cavity within the foil face o the clear cavity side.<br />
Cert. No.<br />
148/08<br />
Yorkshire Building Services (Whitwell) Limited<br />
The Crags Industrial Estate, Morven Street, Creswell, Derbyshire S80 4AJ, United Kingdom<br />
Tel: +44 (0)8449910044 • Fax: +44 (0)8449910055<br />
E-mail: robertq@ybsinsulation.com • Website: www.ybsinsulation.com<br />
Certificate No: 157/11<br />
Certificated Products<br />
Products for Use in<br />
improving thermal<br />
insulation of walls & roofs<br />
Yorkshire Building Services (Whitwell) Limited (YBS) produce a range of products for use<br />
in improving the thermal insulation of walls and roofs. This certificate covers the products<br />
below;<br />
Therma Close - Insulated cavity closer and damp proof barrier for use around openings<br />
in masonry cavity walls.<br />
Therma Close Type R - Insulated cavity closer and damp proof barrier for use around<br />
openings in masonry cavity walls.<br />
Therma-Flect EPS and Therma-Flect PIR (Wall Boards) - Partial fill cavity wall insulation<br />
for improving thermal insulation in external walls of masonry.<br />
Therma-Flect EPS and Therma-Flect PIR (Roof Boards) - Combined thermal insulation<br />
and protection against wind driven rain and snow for use under slates or tiles at rafter<br />
Cert. No.<br />
157/11<br />
20 Nov 2011 529
PART 5: SECTION 9<br />
THERMAL INSULATION SYSTEMS<br />
Certificated Products<br />
level. The bubble foil layer may be located above or below the rafter.<br />
Cavi-Mate EPS and Cavi-Mate Rock fibre cavity closers - Cavity closer providing a<br />
damp-proof barrier and thermal insulation for use around openings in masonry cavity<br />
walls.<br />
Cert. No.<br />
The characteristics of the products and their method of application have been reviewed<br />
with respect to the current Building Regulations, British and European Standards and<br />
other publications in the United Kingdom in November 2011.<br />
530 20 Nov 2011
PART 5: SECTION 10<br />
WALL AND ROOF CLADDING SYSTEMS<br />
The scope of products covered under this scheme is as follows:<br />
Wall and roof cladding products, systems and kits for domestic, commercial and industrial building<br />
applications manufactured from metals, plastics, timber, glass, natural stone, clay and cementitious based<br />
materials and composites to provide decoration, and weather resisting, fire, thermal and acoustic protection.<br />
Eurobrick Systems Limited<br />
Unit 7, Wilverley Trading Estate, Bath Road, Brislington, Bristol BS4 5NL, United Kingdom<br />
Tel: +44 (0)117 971 7117 • Fax: +44 (0)117 971 7217<br />
E-mail: info@eurobrick.co.uk • Website: www.eurobrick.co.uk<br />
Certificate No: 015/93 Reissue 2010<br />
Certificated Products<br />
Eurobrick Insulated Brick<br />
Cladding System<br />
The Eurobrick Insulated Brick Cladding System (Eurobrick System) comprises a<br />
composite backerboard formed from extruded polystyrene insulation board glued to a<br />
profiled polystyrene carrier sheet, brick slips, proprietary mortar and specified ancillary<br />
components. Finished walls have the appearance of traditional brickwork. Where<br />
specified a cavity can be incorporated into the construction behind the insulation by<br />
means of a supporting framework. This application is outside the scope of this certificate.<br />
The Eurobrick System supplied by Eurobrick Systems Limited (Eurobrick) has been<br />
assessed to confirm its suitability for use as a weather resistant, thermal insulating<br />
external decorative finish for application to external vertical walls of new or existing<br />
residential and commercial buildings of masonry, dense concrete, timber or metal frame<br />
construction.<br />
Cert. No.<br />
015/93<br />
reissue<br />
2010<br />
John Brash & Company Ltd<br />
The Old Shipyard, Gainsborough, Lincolnshire DN21 1NG, United Kingdom<br />
Tel: +44 (0)1427 613858 • Fax: +44 (0)1427 810218<br />
E-mail: info@johnbrash.co.uk • Website: www.johnbrash.co.uk<br />
Certificate No: ABP 003 to BRE Product Standard BPS 7002 Issue 1.0<br />
Certificated Products<br />
JB RED Roof tiling battens<br />
The JB RED Roof tiling battens are machine graded timber roof tiling battens with cross<br />
<strong>section</strong>al dimensions of either 25mm x 38mm or 25mm x 50mm made from either<br />
European Redwood or Whitewood from a PEFC/FSC certified source. The battens are<br />
treated with a preservative specified to achieve a 60 year design life for the battens in<br />
accordance with BS 8417 and BS EN 599-1. The preservative supplier provides a 60<br />
year warranty.<br />
Individual battens are marked as follows:<br />
For 25mm x 38mm redwood battens: JOHN BRASH 25x38 PNSY BS5534 JBRED<br />
For 25mm x 50mm redwood battens: JOHN BRASH 25x50 PNSY BS5534 JBRED<br />
For 25mm x 38mm whitewood battens: JOHN BRASH 25x38 WPCA BS5534 JBRED<br />
For 25mm x 50mm whitewood battens: JOHN BRASH 25x38 WPCA BS5534 JBRED<br />
The battens are intended for use as <strong>part</strong> of a timber roofing structure to support concrete,<br />
clay, fibre-cement, natural slate or metal roofing tiles and/or bitumen or wooden shingles.<br />
The preservative treatment applied does not provide resistance to attack by the House<br />
Longhorn beetle.<br />
Cert. No.<br />
ABP 003<br />
20 Nov 2011 531
PART 5: SECTION 10<br />
WALL AND ROOF CLADDING SYSTEMS<br />
Marmorit (UK) GmbH<br />
1 Portview Road, Avonmouth, Bristol BS11 9LS, United Kingdom<br />
Tel: +44 (0)117 982 1042<br />
E-mail: enquiries@marmorit.co.uk • Website: www.marmorit.co.uk<br />
Certificate No: 059/99<br />
Certificated Products<br />
Marmorit Warm Wall<br />
Insulation Systems<br />
1) Warm-wall polystyrene tongue and grooved<br />
2) Warm-wall mineral fibre wool<br />
3) Warm-wall mineral fibre volamit<br />
4) Warm-wall rail system<br />
<br />
<br />
<br />
<br />
polystyrene tongue and grooved<br />
mineral fibre wool<br />
mineral fibre volamit<br />
rail system External Wall Insulation<br />
Marmorit Warm-Wall External Wall Insulation Systems are External Thermal Insulation<br />
Composite Systems (ETICS) and have been assessed to confirm their suitability for use<br />
as external decorative and thermal insulating systems for buildings of masonry or dense<br />
concrete walls in the United Kingdom. The systems consist of an insulant of expanded<br />
polystyrene boards or mineral fibre slabs with a range of cementitious based coloured<br />
coating finishes. The method of providing insulation and fixing to the substrate<br />
determines which of the Marmorit Warm-Wall systems is used.<br />
Cert. No.<br />
059/99<br />
Certificate No: 081/01<br />
Certificated Products<br />
Marmorit Render Systems<br />
Marmorit render systems (finish renders applied to a basecoat) have been assessed to<br />
confirm their suitability for use as a weather resistant external decorative coating on new<br />
and existing walls of either fired-clay brick, or of lightweight or dense aggregate concrete<br />
block, masonry or dense concrete construction or over existing rendering using these<br />
products. They are one coat or two coat ready coloured render system providing various<br />
surface textures and colours.<br />
Cert. No.<br />
081/01<br />
PermaRock Products Limited<br />
Jubilee Drive, Loughborough, Leicestershire LE11 5TW, United Kingdom<br />
Tel: +44 (0)1509 262924<br />
E-mail: info@permarock.com<br />
Certificate No: 029/95<br />
Certificated Products<br />
PermaRock External Wall<br />
Insulation System<br />
The system has been assessed to confirm its suitability as an external decorative and<br />
thermal insulating system for use on masonry, dense and no-fines concrete, timber frame<br />
or steel frame walls. It consists of an insulant of mineral wool or expanded polystyrene<br />
boards with a range of polymer modified render and aggregate finishes, or fired clay brick<br />
slips.<br />
Cert. No.<br />
029/95<br />
Certificate No: 041/97<br />
Certificated Products<br />
PermaRock Phenolic<br />
External Wall Insulation<br />
System<br />
The system has been assessed to confirm its suitability for use as an external decorative<br />
and thermal insulation system for masonry or concrete walls. The system consists of an<br />
insulant of phenolic foam and a range of polymer-modified render and aggregate<br />
finishes.<br />
Cert. No.<br />
041/97<br />
532 20 Nov 2011
PART 5: SECTION 10<br />
WALL AND ROOF CLADDING SYSTEMS<br />
Wienerberger Limited<br />
Wienerberger House, Brooks Drive, Cheadle Royal, Cheadle, Cheshire SK8 3SA, United Kingdom<br />
Tel: +44(0)161 491 8200 • Fax: +44(0)161 491 1270<br />
E-mail: office@wienerberger.co.uk • Website: www.wienerberger.co.uk<br />
Certificate No: 082/01<br />
Certificated Products<br />
Corium<br />
Corium has been assessed to confirm its suitability for use as an external weather<br />
resistant and decorative brick cladding for application to external vertical walls of new or<br />
existing buildings of masonry, dense concrete, timber or metal frame construction in the<br />
UK. The system consists of horizontally mounted steel channel profiles, fitted externally<br />
with brick clay tiles with mortar pointing, to provide a brickwork finish.<br />
Cert. No.<br />
082/01<br />
Z-Led Limited<br />
Plymouth Avenue, Brookhill Industrial Estate, Pinxton, Nottingham NG16 6NS, United Kingdom<br />
Tel: +44 (0)1773 814113 • Fax: +44 (0)1773 814115<br />
E-mail: info@z-led.com • Website: www.z-led.com<br />
Certificate No: 153/10<br />
Certificated Products<br />
Aluflash - coated<br />
aluminium flashing<br />
Aluflash is an aluminium based weathering flashing material. It comprises solvent lacquer<br />
coated embossed aluminium sheet material to BS EN 1396:2007 Aluminium and<br />
aluminium alloys. Coil coated sheet and strip for general applications. Specifications with<br />
a self-adhesive butyl backing for adhesion to roof coverings or masonry. It is available in<br />
flat or cross corrugated versions.<br />
Aluflash is intended for use fully supported as stepped, abutment, chimney and saddle<br />
flashings, to line valleys, box and secret gutters and at upstands to rooflights and solar<br />
panels. Cross corrugated Aluflash is intended for use where the flashing needs to be<br />
moulded over and around complex shapes.<br />
Cert. No.<br />
153/10<br />
20 Nov 2011 533
PART 5: SECTION 11<br />
WALLING, ROOFING AND PARTITION SYSTEMS<br />
The scope of products covered under this scheme is as follows:<br />
Walling, roofing and <strong>part</strong>ition products, systems and kits for building and construction applications<br />
manufactured from gypsum, clay and cementitious based materials, plastics, timber, metals and composites<br />
to provide loadbearing or non loadbearing structures and finishes, decoration and weather resisting, fire,<br />
thermal and acoustic protection.<br />
Kingspan Limited (t/a Profiles and Sections)<br />
Sherburn, Malton, North Yorkshire YO17 8PQ, United Kingdom<br />
Tel: +44 (0)1944 712000 • Fax: +44 (0)1944 710555<br />
E-mail: enquiries@kingspanprofiles.com • Website: www.kingspanprofiles.com<br />
Certificate No: 118/06<br />
Certificated Products<br />
Kingspan Building and<br />
Architectural Façade<br />
Systems<br />
The Kingframe Building and Architectural Façade Systems have been assessed to<br />
confirm suitability for use as building structures (KBS) and as infill construction to form<br />
external facades to steel or concrete framed single and multi storey buildings (AFS).<br />
The Kingframe Building System (KBS) comprises; load-bearing steel stud external wall<br />
frames incorporating specified insulation, load-bearing and non load-bearing internal wall<br />
frames incorporating specified insulation, steel and timber cassette floor panels,<br />
composite concrete floors and steel and timber cassette roof panels.<br />
The Architectural Façade System (AFS) comprises; non load-bearing steel stud wall<br />
frames incorporating specified insulation.<br />
The characteristics of the systems covered by this certificate are:<br />
· Structure<br />
· Behaviour in relation to fire<br />
· Weathertightness<br />
· Thermal transmittance and condensation risk<br />
· Acoustic performance<br />
· Durability<br />
· Factory production and quality control<br />
· Practicality of site installation<br />
The KBS and AFS systems are installed by Kingspan Ltd trained and approved installers.<br />
The KBS and AFS systems have been assessed for use with masonry, render, brick slip,<br />
rainscreen, timber and stone claddings (outside the scope of this certificate) which are<br />
not supplied by Kingspan Ltd but for which performance assessments have been made<br />
in relation to use with the KBS and AFS systems.<br />
The characteristics of The Kingframe Building and Architectural Façade Systems have<br />
been reviewed with respect to the current Building Regulations, British and European<br />
Standards and other publications in the United Kingdom and Ireland in January 2011.<br />
Cert. No.<br />
118/06<br />
Logix UK Limited (Simplipac)<br />
57 Balena Close, Creekmoor Industrial Estate, Poole, Dorset BH17 7DG, United Kingdom<br />
Tel: +44 (0)1202 694 259 • Fax: +44 (0)1202 600 640<br />
E-mail: enquiries@logix.uk.com • Website: www.logix.uk.com<br />
Certificate No: 122/06<br />
Certificated Products<br />
Logix ICF Blocks<br />
Logix ICF blocks have been assessed to confirm, within limitations, their suitability as a<br />
permanent Insulating Concrete Formwork (ICF) system. The forms of the system can be<br />
<strong>part</strong>ly assembled off site (panelised) or fully assembled on site (in-situ) to produce a<br />
Cert. No.<br />
122/06<br />
534 20 Nov 2011
PART 5: SECTION 11<br />
WALLING, ROOFING AND PARTITION SYSTEMS<br />
Certificated Products<br />
permanent formwork (shuttering), which is filled with a defined concrete mix and steel<br />
reinforcement where required. The resultant concrete walls with expanded polystyrene<br />
(EPS) panels either side can be used as either load-bearing or non load-bearing<br />
insulated walls in residential or commercial buildings. Only walls where the height of the<br />
top floor above ground, in a building or separated <strong>part</strong> of a building is not more than 18m<br />
are covered by this certificate.<br />
The forms comprise of two EPS panels each having a thickness of 70mm. They are held<br />
a<strong>part</strong> at either: 100mm (Logix4), or 159mm (Logix6) or 203mm (Logix8) forms, by<br />
proprietary polypropylene ties moulded into the EPS panels at 203mm centres. The<br />
forms have a nominal height of 203mm (half height) or 406mm (full height). The lengths<br />
of the forms are typically 1219mm. The forms are produced in straight, 45 o or 90 o plan<br />
<strong>section</strong>s. Both internal and external faces of the finished walls require the addition of a<br />
protective cladding not covered by this certificate.<br />
The characteristics of the product and the method of application have been reviewed with<br />
respect to the Building Regulations current in the United Kingdom. The assessment has<br />
referred to British Standards and other publications current when this certificate was<br />
issued.<br />
Cert. No.<br />
20 Nov 2011 535
PART 5: SECTION 12<br />
CONSERVATION OF FUEL AND POWER<br />
Products covered under this scheme have been demonstrated to aid the conservation of fuel and power in<br />
buildings.<br />
Energy Control Systems Ltd<br />
Pipsden Lodge, Rye Road, Hawkhurst, Kent TN18 5DN, United Kingdom<br />
Tel: +44 (0)1580 753682<br />
Website: www.energy-control-systems.no<br />
Distributed and Installed by Dynamic Energy Products Ltd<br />
Fig Tree House, Dymchurch Road, St Mary's Bay, Kent TN29 0HF, United Kingdom<br />
Tel: +44 (0)1797 367400 • Fax: +44 (0)1797 367400<br />
E-mail: thermsave@aol.com<br />
Certificate No: CFP 348<br />
Certificated Products<br />
Burner Management Unit<br />
BM1 and Dynamic Burner<br />
Management Unit DBMU<br />
The Burner Management is designed to modify the burner-firing pattern of conventional<br />
commercial boilers and water heaters (with 40kW input or greater) to minimise wasteful<br />
over-firing. The effectiveness of the Burner Management Unit has been tested on a<br />
typical open-flued commercial boiler (rated at 63kW) subject to a fully repeatable load<br />
pattern over a course of back-to-back tests with the Burner Management Unit both in and<br />
out of circuit.<br />
Cert. No.<br />
CFP 348<br />
536 20 Nov 2011
Part<br />
6<br />
MANAGEMENT SYSTEM<br />
CERTIFICATION
PART 6: MANAGEMENT SYSTEM CERTIFICATION<br />
Introduction<br />
We offer approval to the three key management system standards for:<br />
Quality - ISO 9001<br />
Now one of the world’s leading management system standards, ISO 9001 gives confidence to customers that<br />
the businesses they trade with have consistent levels of quality and service.<br />
Environmental Management - ISO 14001<br />
Approval to ISO 14001 demonstrates a company’s commitment to the environment and provides an<br />
assurance to the public, regulators and purchasers that its environmental policies and procedures are<br />
effective.<br />
Health and Safety - BS OHSAS 18001<br />
This is a specification that helps to fully integrate health and safety into company policies and working<br />
practices. It also signals to architects, clients, insurers and specifiers that a company takes its health and<br />
safety responsibilities seriously.<br />
As well as providing approval to each individually, we offer an integrated service to companies wanting<br />
approval under two or more of these management system standards.<br />
538 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Approval of a Quality Management System demonstrates that a company’s internal systems and processes<br />
are in place and operating as intended. It also measures performance in delivering products or services to an<br />
agreed standard.<br />
Third <strong>part</strong>y approval is an independent review of a <strong>part</strong>icular area of a company’s activities, which leads to<br />
improved processes and increased consumer confidence, and can help to reduce costs. Under the<br />
International Standard, ISO 9001, the certificate identifies which <strong>part</strong>s of a company’s activities are covered,<br />
and must include design if this is <strong>part</strong> of its operation.<br />
This scheme is for companies whose Quality Management Systems have been designed to meet the<br />
requirements of ISO 9001. For companies that already have a certificated Quality Management System<br />
assessed to ISO 9001, we offer approval of the factory production control processes applicable to the<br />
products we approve, and these are detailed in the entries listed where that option has been taken.<br />
The entries in this <strong>section</strong> define the scope of activities that have been assessed under the management<br />
system.<br />
Unlike our product approval schemes, which relate to specific products and services, Quality Management<br />
Systems approval can encompass the complete scope of a firm's activities at that <strong>part</strong>icular address.<br />
However, it is important to understand that ISO 9001 does not provide an assurance to the user or specifiers<br />
that actual products or services conform to requirements, since no testing or cross checking of conformity to<br />
product or service standards is involved. Therefore, no marking of specific products or installations is<br />
permitted.<br />
For companies operating in the fire and security areas with LPCB product or service approvals, our ISO 9001<br />
approval is given in the name of LPCB. Where companies do not require LPCB product or service<br />
certification, then all certificates are issued in the name of BRE Global Limited.<br />
2M KABLO SAN. ve TIC. A.S.<br />
Sanayi Mahallesi, 1678 Sokak No: 3, 34511 Esenyurt, Istanbul, Turkey<br />
Tel: +90 212 672 7314 • Fax: +90 212 672 7312<br />
E-mail: sales@2mkab.com • Website: www.2mkab.com<br />
Also at:<br />
Perpa Ticaret Merkezi, A Blok Kat:8, No.707, Okmeydani, Istanbul, Turkey<br />
Quality System Cert. No. 711 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of electric cables for use in installations that require safety in the event of fire.<br />
A & F Sprinklers Limited<br />
Atrium House, 574 Manchester Road, Blackford Bridge, Bury, Lancashire BL9 9SW, United Kingdom<br />
Tel: +44 (0)845 505 1550 • Fax: +44 (0)845 505 1660<br />
E-mail: info@afsprinklers.co.uk • Website: www.afsprinklers.co.uk<br />
Quality System Cert. No. 049 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and installation of fire sprinkler and water spray systems.<br />
20 Nov 2011 539
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
A M Profiles Limited<br />
Hardwick View Road, Holmewood Industrial Estate, Holmewood, Chesterfield, Derbyshire S42 5SA, United<br />
Kingdom<br />
Tel: +44 (0)1246 856000 • Fax: +44 (0)1246 855105<br />
E-mail: sales@amprofiles.com<br />
Quality System Cert. No. 808 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacturing and installation of architectural aluminium and composite glazing.<br />
A Steadman & Son<br />
(a division of SIG Trading Ltd), Warnell, Welton, Carlisle, Cumbria CA5 7HH, United Kingdom<br />
Tel: +44 (0)16974 78277 • Fax: +44 (0)16974 78530<br />
E-mail: info@steadmans.co.uk • Website: www.steadmans.co.uk<br />
Quality System Cert. No. 635 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of AS35 sandwich roof and wall panels. Manufacture of cold rolled <strong>section</strong>, including purlins, facias and fittings associated<br />
with wall and roof panels.<br />
A.C. Plastic Industries Limited<br />
Unit J Loddon Business Centre, Roentgen Road, Basingstoke, Hants RG24 8NG, United Kingdom<br />
Tel: +44 (0)1256 329334 • Fax: +44 (0)1256 817862<br />
E-mail: sales@ac-plastics.com • Website: www.ac-plastics.com<br />
Quality System Cert. No. 065 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of hot press moulded GRP <strong>section</strong>al water storage tanks.<br />
A.M. Fire Systems Limited<br />
Red Brook Mill, Bury Road, Rochdale OL11 4EE, United Kingdom<br />
Tel: +44 (0)1706 639439 • Fax: +44 (0)1706 347733<br />
E-mail: andyedmunds@amfiresystems.co.uk<br />
Quality System Cert. No. 357 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and installation of fire sprinkler, water spray and foam systems.<br />
Abbot Fire Group Limited<br />
Abbots Barn, Radclive Road, Gawcott, Buckingham MK18 4AA, United Kingdom<br />
Tel: +44 (0)870 844 1666 • Fax: +44 (0)870 844 1777<br />
E-mail: admin@abbotfiregroup.co.uk<br />
Quality System Cert. No. 586 Assessed to ISO 9001:2008<br />
Scope:<br />
Installation and servicing of portable fire extinguishers. Installation and servicing of kitchen suppression systems.<br />
540 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
AccentHansen<br />
Greengate Industrial Park, Greengate, Middleton, Manchester M24 1SW, United Kingdom<br />
Tel: +44 (0)161 284 4100 • Fax: +44 (0)161 655 3119<br />
E-mail: info@accenthansen.co.uk • Website: www.servicehansen.com<br />
Quality System Cert. No. 021 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of industrial doors, security doors and fire doors.<br />
Actionair<br />
Ruskin Air Management, Joseph Wilson Industrial Estate, South Street, Whitstable, Kent CT5 3DU, United<br />
Kingdom<br />
Tel: +44 (0)1227 276100 • Fax: +44 (0)1227 264262<br />
E-mail: sales@actionair.co.uk • Website: www.actionair.co.uk<br />
Quality System Cert. No. 017 Assessed to ISO 9001:2008<br />
Scope:<br />
The design, manufacture and supply of fire protection and air distribution products including: Electrically or pneumatically operated fire<br />
smoke dampers; Thermal release or electro magnetic release curtain fire dampers; Manually, electrically or pneumatically operated<br />
volume control and shut off dampers; Fan coil units; Control systems and ancillary products.<br />
AD Sprinkler Protection Limited<br />
2/8 Heaton Mill, Grey Street, Denton, Manchester M34 3RG, United Kingdom<br />
Tel: +44 (0)161 336 0001 • Fax: +44 (0)161 336 6608<br />
E-mail: mail@adsprinklers.co.uk • Website: www.adsprinklers.co.uk<br />
Quality System Cert. No. 916 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and service of fire sprinkler systems.<br />
Advanced Electronics Limited<br />
34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom<br />
Tel: +44 (0) 1226 737 465 • Fax: +44 (0) 1226 737 469<br />
E-mail: ithompson@advel.co.uk • Website: www.Advel.co.uk<br />
Also at:<br />
2 Claycliffe Office Park, Whaley Road, Barnsley, South Yorkshire S75 1HT, United Kingdom<br />
Quality System Cert. No. 544 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection panels, emergency lighting and safety control equipment.<br />
AEI Cables Limited<br />
Birtley, Chester-le-Street, Co. Durham DH3 2RA, United Kingdom<br />
Tel: +44 (0)191 410 3111 • Fax: +44 (0)191 410 8312<br />
E-mail: sales@aeicables.co.uk • Website: www.aeicables.co.uk<br />
Quality System Cert. No. 221 Assessed to ISO 9001:2008<br />
Scope:<br />
20 Nov 2011 541
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Design and manufacture of electric cables for use in fire alarm installations.<br />
Alliance Valves and Piping Supplies Limited 'AVPS'<br />
Unit 2, Royd Business Park, Dyehouse Lane, Brighouse, West Yorkshire HD6 1LL, United Kingdom<br />
Tel: +44 (0)1484 401880 • Fax: +44 (0)1484 401881<br />
E-mail: sales@alliancevalves.co.uk • Website: www.alliancevalves.co.uk<br />
Quality System Cert. No. 797 Assessed to ISO 9001:2008<br />
Scope:<br />
Supply of process and instrumentation valves fittings as associated for the oil, petrochemical and associated sectors.<br />
Alpine Fire Engineers Limited<br />
Sovereign House, Barehill Street, Littleborough, Lancashire OL15 9BL, United Kingdom<br />
Tel: +44 (0)1706 838200 • Fax: +44 (0)1706 838020<br />
E-mail: d.smith@alpinefire.co.uk • Website: www.alpinefire.co.uk<br />
Quality System Cert. No. 283 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, service and installation of fire sprinkler systems.<br />
Aluroll Limited<br />
Mile Oak Industrial Estate, Maesbury Road, Oswestry, Shropshire SY10 8GA, United Kingdom<br />
Tel: +44 (0)800 977 8975 • Fax: +44 (0)1691 671 482<br />
E-mail: enquiry@aluroll.co.uk • Website: www.aluroll.co.uk<br />
Quality System Cert. No. 931 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and fabrication of security shutters and garage doors and assembly and supply of photovoltaic systems.<br />
AMPAC Europe Limited<br />
Unit 18 Networkcentre, Yorkshire Way, Westmoor Park, Doncaster DN3 3GW, United Kingdom<br />
Tel: +44 (0)1302 833522 • Fax: +44 (0)1302 835021<br />
E-mail: info@ampac.net • Website: www.ampac.net<br />
Quality System Cert. No. 952 Assessed to ISO 9001:2008<br />
Scope:<br />
The marketing, assembly and distribution of fire detection and emergency warning products and associated training.<br />
Ampac Security Products Limited<br />
Saxon Way, Melbourn, Royston, Hertfordshire SG8 6DN, United Kingdom<br />
Tel: +44 (0)1763 261900 • Fax: +44 (0)1763 261234<br />
Website: www.ampaconline.com<br />
Quality System Cert. No. 822 Assessed to ISO 9001:2008<br />
Scope:<br />
The manufacture of tamper evident polythene security bags and envelopes.<br />
542 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Andreu Barbera S.L.<br />
Poligono Fuente Del Jarro, C/Ciudad De Sevilla, 20, 46988 Paterna, Valencia, Spain<br />
Tel: +34 96134 3100 • Fax: +34 961 34 0859<br />
E-mail: andreu@andreu.es • Website: www.andreu.es<br />
Quality System Cert. No. 922 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Design and production of metallic door sets and accessories.<br />
Ansul Incorporated<br />
One Stanton Street, Marinette, Wisconsin 54143-2542, United States<br />
Tel: +1 715 735 7411 • Fax: +1 715 732 3477<br />
Website: www.ansul.com<br />
Quality System Cert. No. 591 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of restaurant fire protection systems and fire suppression wet agents.<br />
Anvil International Inc.<br />
1411 Lancaster Avenue, Columbia, Pennsylvania 17512, United States<br />
Tel: +1 717 684 4400 • Fax: +1 717 684 2131<br />
Website: www.anvilintl.com<br />
Quality System Cert. No. 119 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of pipe couplings fittings and valves. Malleable and gray iron threaded fittings and pipe hangers.<br />
Anvil International Inc.<br />
2870 Old Jackson Road, Henderson, Tennessee 38340, United States<br />
Tel: +1 731 989 3551 • Fax: +1 731 989 4144<br />
Quality System Cert. No. 177 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of pipe hangers. Metal stamping and fabrication.<br />
Apollo (Beijing) Fire Products Co Ltd<br />
No. 5, Industrial District North-West Jia, Jiugong Town Daxing District, Beijing 100076, China<br />
Tel: +86 10 8361 7122 • Fax: +86 10 8361 7017<br />
E-mail: lhxf@uip.163.com<br />
Quality System Cert. No. 1032 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, service and repair of fire detectors and alarm system components.<br />
20 Nov 2011 543
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Apollo Fire Detectors Limited<br />
36 Brookside Road, Havant, Hampshire PO9 1JR, United Kingdom<br />
Tel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754<br />
E-mail: enquiries@apollo-fire.co.uk<br />
Quality System Cert. No. 010 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, service and repair of fire detectors for commercial/industrial applications.<br />
APW Fire Protection Limited<br />
Unit A, Marlfield Factory, Front Road, Drumbo, Lisburn BT27 5JY, United Kingdom<br />
Tel: +44 (0)28 90827046 • Fax: +44 (0)28 90827049<br />
E-mail: will@apwfp.com<br />
Quality System Cert. No. 866 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
ArcelorMittal Construction Belgium<br />
Zone Industrielle de Martinrou, 21b rue de Berlaimont, Fleurus, Belgium<br />
Tel: +32 (0) 718 70540 • Fax: +32 (0) 718 70541<br />
Website: www.arcelormittal.com<br />
Quality System Cert. No. 737 Assessed to ISO 9001:2008<br />
Scope:<br />
Sales and manufacture of mineral wool insulation panels for construction.<br />
ArcelorMittal Construction Belgium NV<br />
Lammerdries 8, Industrieterrein Geel West Z4, B-2440 Geel, Belgium<br />
Tel: +32 14563943 • Fax: +32 14563952<br />
E-mail: eric.mees@arcelormittal.com • Website: www.arclad.be<br />
Quality System Cert. No. 939 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Production of sandwich panels for industrial and utility buildings.<br />
Argus Fire Protection Company Limited<br />
Hendglade House, 46 New Road, Stourbridge, West Midlands DY8 1PA, United Kingdom<br />
Tel: +44 (0)1384 376256 • Fax: +44 (0)1384 393955<br />
E-mail: info@argusfire.co.uk • Website: www.argusfire.co.uk<br />
Quality System Cert. No. 011 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and installation of fire sprinkler, water spray and foam systems. Installation, commissioning and servicing of fire detection and<br />
alarm systems.<br />
544 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Argus-Spectrum Co<br />
65 Serdobolskaya St, St. Petersburg 197342, Russian Federation<br />
Tel: +7 812 7037500 • Fax: +7 812 7037501<br />
E-mail: mail@argus-spectr.ru • Website: www.argus-spectr.ru<br />
Quality System Cert. No. 603 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire and security alarm system components<br />
Armstrong Priestley Limited<br />
Seventy Seven, Holbeck Lane, Leeds LS11 9UL, United Kingdom<br />
Tel: +44 (0)113 3944040 • Fax: +44 (0)113 3944041<br />
E-mail: info@armstrongpriestley.co.uk • Website: www.armstrongpriestley.co.uk<br />
Quality System Cert. No. 109 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler, water spray and foam systems, hydrants and hose reels. Fabrication of pipework for fire<br />
sprinkler systems.<br />
Ascot Doors Limited<br />
Britannia Way Industrial Park, Union Road, Bolton BL2 2HE, United Kingdom<br />
Tel: +44 (0)1204 545801 • Fax: +44 (0)1204 545800<br />
E-mail: sales@ascotdoors.co.uk • Website: www.ascotdoors.co.uk<br />
Quality System Cert. No. 131 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture, installation, servicing and repair of industrial doors, industrial rolling shutters, fire doors and fire rolling shutters.<br />
Ashvale Fire Services Limited<br />
Ashvale House, Fitzroy Street, Ashton-under-Lyne, Lancashire OL7 0JG, United Kingdom<br />
Tel: +44 (0)161 343 1090 • Fax: +44 (0)161 343 3732<br />
E-mail: sales@ashvalefire.co.uk • Website: www.ashvalefireservices.com<br />
Quality System Cert. No. 275 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
ASLR Fabrication Services Limited<br />
Opal Way, Stone Business Park, Stone, Staffordshire ST15 0SS, United Kingdom<br />
Tel: +44 (0)1785 286060 • Fax: +44 (0)1785 818728<br />
E-mail: sales@aslr.co.uk • Website: www.aslr.co.uk<br />
Quality System Cert. No. 1072 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and supply of pre fabricated pipework for the fire protection, building services, water and process engineering industries.<br />
20 Nov 2011 545
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
ATOM KABLO SANAYI VE TICARET A.S.<br />
Ankara Karayolu 6. Km, Akkale Bedesi, Denizli 20155, Turkey<br />
Tel: +90 258 274 63 52 • Fax: +90 258 274 64 31<br />
E-mail: atom@atom.com.tr • Website: www.atom.com.tr<br />
Quality System Cert. No. 905 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
The manufacture and suppy of electric cables and wires, including cables used for installations which require safety in the event of fire.<br />
Attenborough Doors Limited<br />
Merlin Way, Quarry Hill Industrial Estate, Ilkeston, Derbyshire DE7 4RA, United Kingdom<br />
Tel: +44 (0)115 9300815 • Fax: +44 (0)115 9448930<br />
E-mail: information@attenboroughdoor.co.uk • Website: www.attenboroughdoor.co.uk<br />
Quality System Cert. No. 145 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of industrial rolling shutters and fire rolling shutters.<br />
Automatic Fire Control Limited<br />
Unit 7 Kingsdown Orchard, Hyde Road, Swindon SN2 7RR, United Kingdom<br />
Tel: +44 (0)1793 821588 • Fax: +44 (0)1793 821587<br />
E-mail: info@automaticfire.co.uk<br />
Quality System Cert. No. 101 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler and water spray systems.<br />
Bahra Cables Company<br />
CPC Industrial Park, Bahra, Jeddah 21432, Kingdom of Saudi Arabia<br />
Tel: +966 25911115, (Toll Free) 8001248111 • Fax: +966 25915683<br />
E-mail: fsb@bahra-cables.com • Website: www.bahra-cables.com<br />
Quality System Cert. No. 1069 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of single core fire resistant cables tested to BS 6387:1994 Cat CWZ. Conductor cross <strong>section</strong>al area 2.5mm 2 - 25mm 2 .<br />
Bailey & Mackey Limited<br />
Baltimore Road, Birmingham B42 1DE, United Kingdom<br />
Tel: +44 (0)121 357 5351 • Fax: +44 (0)121 357 8319<br />
E-mail: enquiries@baileymackey.com • Website: www.baileymackey.com<br />
Quality System Cert. No. 085 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of calibrated pressure gauges, pressure switches, pressure transducers and vapour pressure temperature<br />
gauges. Repair and re-calibration of pressure gauges, pressure switches, pressure transducers and vapour pressure temperature<br />
gauges, in the range of absolute vacuum up to 1000 bar gauge, and temperature range of 20 degrees celsius up to 200 degrees celsius.<br />
546 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Balmoral Sectional Tanks Limited<br />
(A Division of Balmoral Group Holdings Limited), Balmoral Park, Loirston, Aberdeen AB12 3GY, United<br />
Kingdom<br />
Tel: +44 (0)1224 859000 • Fax: +44 (0)1224 859123<br />
E-mail: tanks@balmoral.co.uk • Website: www.balmoraltanks.com<br />
Quality System Cert. No. 445 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of hot press moulded GRP <strong>section</strong>al water storage tanks.<br />
Bangkok Cable Co Limited<br />
187/1 Rajdamri Road, Lumpinee, Pathumwan, Bangkok 10330, Thailand<br />
Tel: +662 254 4550 • Fax: +662 254 3859<br />
E-mail: sales@bangkokcable.com<br />
Manufacture at:<br />
93 Moo. 11, Suksawad Rd, Naiklongbangplakod, Prasamutchedee, Samutprakarn 10290, Thailand<br />
Quality System Cert. No. 576 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of cables for use in installations that require safety in the event of fire.<br />
BBC Fire Protection Limited<br />
St Florian House, Ayton Road, Wymondham, Norfolk NR18 0QH, United Kingdom<br />
Tel: +44 (0)1953 857700 • Fax: +44 (0)1953 857750<br />
E-mail: sales@bbcfire.co.uk • Website: www.bbcfire.co.uk<br />
Quality System Cert. No. 346 Assessed to ISO 9001:2008<br />
Scope:<br />
Installation, commissioning and servicing of fire detection and alarm systems.<br />
Beijing Siemens Cerberus Electronics Limited<br />
No. 1, Feng Zhi Dong Lu, Xi Bei Wang, Haidian District, Beijing 100094, China<br />
Tel: +86 010 629 62255 • Fax: +86 010 629 87387<br />
E-mail: hongyan.lv@siemens.com<br />
Quality System Cert. No. 531 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm equipment, intruder detection and alarm equipment. Design and manufacture of<br />
electronic and mechanical control products and systems for HVAC applications, room-controls and building automation.<br />
Besseges Limited<br />
Riverside, Dukinfield, Cheshire SK16 4HE, United Kingdom<br />
Tel: +44 (0)161 308 3252 • Fax: +44 (0)161 339 5003<br />
E-mail: sales@besseges.co.uk • Website: www.besseges.co.uk<br />
Quality System Cert. No. 071 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems. Fabrication of pipework.<br />
20 Nov 2011 547
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Biamp Systems Corporation<br />
9300 S.W. Gemini Drive, Beaverton, Oregon 97008, United States<br />
Tel: +1 503 718 9212 • Fax: +1 503 626 0281<br />
Website: www.biamp.com<br />
Quality System Cert. No. 977 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacturer of audio equipment including voice alarm control and indicating equipment.<br />
Blue Shield Fire Protection Limited<br />
Blue Shield House, Queen Street, Tring, Hertfordshire HP23 6BQ, United Kingdom<br />
Tel: +44 (0)1442 828000 • Fax: +44 (0)1442 828001<br />
E-mail: sales@blueshieldfire.co.uk • Website: www.blueshieldfire.co.uk<br />
Quality System Cert. No. 667 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, service and repair of fire sprinkler systems.<br />
Bolton Gate Co. Limited<br />
Waterloo Street, Bolton, Lancashire BL1 2SP, United Kingdom<br />
Tel: +44 (0)1204 871000 • Fax: +44 (0)1204 871049<br />
E-mail: kb@boltongate.co.uk • Website: www.boltongate.co.uk<br />
Quality System Cert. No. 026-2 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of industrial doors, industrial rolling shutters, fire doors and fire rolling shutters.<br />
Booth Industries Limited<br />
P.O. Box 50, Nelson Street, Bolton, Lancashire BL3 2AP, United Kingdom<br />
Tel: +44 (0)1204 366333 • Fax: +44 (0)1204 380888<br />
E-mail: marketing@booth-industries.co.uk • Website: www.booth-industries.co.uk<br />
Also at:<br />
Unit D, Lecturers Close, Bridgeman Street, Bolton BL3 6DG, United Kingdom<br />
Quality System Cert. No. 816 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of blast walls, blast panels and blast doors. Manufacture of fire walls, fire panels, fire doors, security doors and<br />
industrial doors.<br />
BPI Visqueen - Greenock<br />
96 Port Glasgow Road, Greenock, Scotland PA15 2UL, United Kingdom<br />
Tel: +44 (0)1475 501100 • Fax: +44 (0)1475 743256<br />
Website: www.bpipoly.com<br />
Quality System Cert. No. 521 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of flame retardant plastic protection material.<br />
548 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Bradbury Security<br />
Dunlop Way, Queensway Industrial Estate, Scunthorpe DN16 3RN, United Kingdom<br />
Tel: +44 (0)1724 271999 • Fax: +44 (0)1724 271888<br />
E-mail: sales@bradburyuk.com • Website: www.bradburyuk.com<br />
Quality System Cert. No. 312 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of physical security products.<br />
Braithwaite Engineers Limited<br />
Neptune Works, Uskway, Newport, South Wales NP20 2UY, United Kingdom<br />
Tel: +44 (0)1633 262141 • Fax: +44 (0)1633 250631<br />
E-mail: tanks@braithwaite.co.uk • Website: www.braithwaite.co.uk<br />
Quality System Cert. No. 103 Assessed to ISO 9001:2008<br />
Scope:<br />
The design, supply and installation of <strong>section</strong>al pressed steel tanks and glass reinforced plastic (GRP) cold water storage tanks, including<br />
the manufacture of custom GRP panels and components.<br />
Brammall Inc.<br />
Doing business as Tyden Brooks Security Products, 409 Hoosier Drive, Angola, Indiana 46703, United States<br />
Tel: +1 260 665 3176 • Fax: +1 260 665 8309<br />
E-mail: insidesales@tydenbrooks.com • Website: www.tydenbrooks.com<br />
Quality System Cert. No. 779 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of cargo security seals.<br />
Britannia Kitchen Ventilation Limited<br />
10 Highdown Road, Leamington Spa, Warwickshire CV31 1XT, United Kingdom<br />
Tel: +44 (0)1926 463540 • Fax: +44 (0)1926 463941<br />
E-mail: sales@kitchen-ventilation.co.uk • Website: www.kitchen-ventilation.co.uk<br />
Quality System Cert. No. 1085 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of commercial and institutional kitchen ventilation canopies and associated equipment.<br />
BSB Engineering Services Limited<br />
Unit E, Tribune Drive, Trinity Trading Estate, Sittingbourne, Kent ME10 2PD, United Kingdom<br />
Tel: +44 (0)1795 422609 • Fax: +44 (0)1795 429543<br />
E-mail: sales@bsb-dampers.co.uk • Website: www.bsb-dampers.co.uk<br />
Quality System Cert. No. 828 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of fire dampers (fire curtains), fire smoke dampers, smoke control dampers and volume control dampers.<br />
20 Nov 2011 549
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Burton Safes Limited<br />
Unit 12, Brockholes Business Park, Rockmill Road, Brockholes, Holmfirth HD9 7BN, United Kingdom<br />
Tel: +44 (0)1484 663388 • Fax: +44 (0)1484 666338<br />
Website: www.burtonsafes.co.uk<br />
Quality System Cert. No. 1000 Assessed to ISO 9001:2008<br />
Scope:<br />
Distribution, supply and commissioning of safes, safe locks, strong rooms and security cabinets.<br />
Bush (Fire Engineering) Limited<br />
Unit 28 The Metro Centre, Kangley Bridge Road, Sydenham, London SE26 5BW, United Kingdom<br />
Tel: +44 (0)845 241 9860 • Fax: +44 (0)845 241 9861<br />
E-mail: sales@bushengineering.com<br />
Quality System Cert. No. 385 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems. Installation and servicing of dry risers.<br />
CA Group Limited<br />
Evenwood Industrial Estate, Copeland Road, Evenwood, Co. Durham DL14 9SF, United Kingdom<br />
Tel: +44 (0)1388 834242 • Fax: +44(0)1388 834881<br />
E-mail: help@cagroup.ltd.uk • Website: www.cagroup.ltd.uk<br />
Quality System Cert. No. 443 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of built-up roof and wall systems.<br />
Cavicel SpA<br />
Via Caduti del Lavoro, 18/A, 20096 Pioltello, Milan, Italy<br />
Tel: +39 02 9216 0521 • Fax: +39 02 9216 0753<br />
E-mail: cavicel@cavicel.com • Website: www.cavicel.com<br />
Quality System Cert. No. 217 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of electric cables for installations that require safety in the event of fire.<br />
Ceodeux - Firetec<br />
24 Route de Diekirch - B.P.19, L-7505 Lintgen, Luxembourg<br />
Tel: +352 32 78 32-1 • Fax: +352 32 78 32-326<br />
E-mail: info@firetec.rotarex.com • Website: www.rotarex.com<br />
Quality System Cert. No. 724 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Development, assembly, test and sale of BO480 differential pressure valves for fire suppression systems.<br />
550 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Chaoyi Industry Development<br />
3/F No. 4 Factory Building, Lang Kou Industrial Estate, Lang Kou Road, Lang Hau, Bao An District,<br />
Shenzhen, China<br />
Tel: +755 338 76556 • Fax: +755 338 76538<br />
E-mail: szchaoyi@163.com<br />
Quality System Cert. No. 876 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of fire alarm bells.<br />
Charter Sepcialist Security Limited<br />
Innovation House, Arkwright Road, Reading, Berkshire RG2 0LU, United Kingdom<br />
Tel: +44 (0) 845 0508705 • Fax: +44 (0) 845 0508707<br />
E-mail: sales@chatergroupuk.com • Website: www.chartergroupuk.com<br />
Quality System Cert. No. 1075 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, fabrication, installation and repair of roller shutter systems.<br />
Chemring Energetics Limited<br />
Ardeer Site, Stevenston, Ayrshire, Scotland KA20 3LN, United Kingdom<br />
Tel: +44 (0)1294 487007 • Fax: +44 (0)1294 487230<br />
E-mail: campbell.howie@chemringenergetics.co.uk • Website: www.chemringenergetics.co.uk<br />
Quality System Cert. No. 313 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of Metron actuators for installation in fire fighting systems.<br />
Chubb Fire & Security Limited<br />
400 Dallow Road, Luton, Beds LU1 1UR, United Kingdom<br />
Tel: +44 (0)1582 413694 • Fax: +44 (0)1582 456353<br />
E-mail: quality.fireuk@chubb.co.uk • Website: www.chubb.co.uk<br />
Quality System Cert. No. 315 Assessed to ISO 9001:2008<br />
Scope:<br />
Installation, commissioning and servicing of fire detection and alarm systems.<br />
Chubb Fire & Security Limited<br />
5 Canal Place, Armley Road, Leeds LS12 2DU, United Kingdom<br />
Tel: +44 (0)113 235 5131 • Fax: +44 (0)113 235 5132<br />
E-mail: fire.leeds@chubb.co.uk • Website: www.chubb.co.uk<br />
Quality System Cert. No. 309 Assessed to ISO 9001:2008<br />
Scope:<br />
Installation, commissioning and servicing of fire detection and alarm systems.<br />
20 Nov 2011 551
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Circum Limited<br />
Roundhouse Farm, Roestock Lane, Colney Heath, Hertfordshire AL4 0PP, United Kingdom<br />
Tel: +44 (0)1727 821228 • Fax: +44 (0)1727 822428<br />
E-mail: sfulcher@circum.ltd.uk • Website: www.circum.ltd.uk<br />
Quality System Cert. No. 892 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, service and maintenance of fire sprinkler systems, gas suppression systems and the sale of associated fire products.<br />
Clark Door Limited<br />
Unit F Central, Kingmoor Park, Carlisle, Cumbria CA6 4SJ, United Kingdom<br />
Tel: +44 (0)1228 522321 • Fax: +44 (0)1228 401854<br />
E-mail: mail@clarkdoor.com • Website: www.clarkdoor.com<br />
Quality System Cert. No. 106 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of industrial doors, industrial rolling shutters, fire doors and fire rolling shutters.<br />
CLD Fencing Systems<br />
Unit 11, Springvale Business Centre, Millbuck Way, Sandbach, Cheshire CW11 3HY, United Kingdom<br />
Tel: +44 (0)1270 764751 • Fax: +44 (0)1270 757503<br />
E-mail: info@cld-fencing.com • Website: www.cld-fencing.com<br />
Quality System Cert. No. 999 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of perimeter, security and sports fencing systems.<br />
Clearway Environmental Services (UK) Limited<br />
11 Landau Way, Darent Industrial Park, Erith, Kent DA8 2LF, United Kingdom<br />
Tel: +44 (0)1322 332211 • Fax: +44 (0)1322 339582<br />
E-mail: info@clearwayservices.co.uk • Website: www.clearwayservices.co.uk<br />
Quality System Cert. No. 1001 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Provision and installation of security doorsets for property protection.<br />
Clymac Limited<br />
Cloudway Court, Belton Road, Loughborough LE11 1LW, United Kingdom<br />
Tel: +44 (0)1509 232651 • Fax: +44 (0)1509 232665<br />
E-mail: sales@clymac.co.uk • Website: www.clymac.co.uk<br />
Quality System Cert. No. 687 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, supply, installation, commissioning and servicing of fire detection and alarm systems.<br />
552 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Compco Fire Systems Limited<br />
Cleeve House, Malvern Road, Lower Wick, Worcester WR2 4YX, United Kingdom<br />
Tel: +44 (0)1905 741600 • Fax: +44 (0)1905 741620<br />
E-mail: enquiries@compcofire.co.uk<br />
Also at:<br />
High Banks House, Lawn Lane, Hemel Hempstead, Hertfordshire HP3 9HR, United Kingdom<br />
Tel: +44 (0)1442 242821<br />
and<br />
23 Fairfield Place, College Milton, East Kilbride G74 5LP, United Kingdom<br />
Tel: +44 (0)1355 570033 • Fax: +44 (0)1355 570044<br />
E-mail: david.m@compcofire.co.uk<br />
Quality System Cert. No. 274 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler and foam systems, and hose reels.<br />
Computionics Limited (Trading as C-Tec)<br />
Stephens Way, Goose Green, Wigan, Lancashire WN3 6PH, United Kingdom<br />
Tel: +44 (0)1942 322744/42444 • Fax: +44 (0)1942 829867<br />
E-mail: sales@C-tec.co.uk • Website: www.c-tec.co.uk<br />
Also at:<br />
Dark Lane, Mawdesley L40 2QU, United Kingdom<br />
Quality System Cert. No. 176 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire and security control and indicating equipment, associated alarm system components, and call equipment.<br />
Control Equipment Limited<br />
Hillcrest Business Park, Dudley, West Midlands DY2 9AP, United Kingdom<br />
Tel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972<br />
E-mail: celsales@controlequipment.co.uk • Website: www.controlequipment.com<br />
Quality System Cert. No. 018 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of detection and electronic control equipment for fire protection and other PCB assembly.<br />
Cooper Fulleon Limited<br />
Llantarnam Park, Cwmbran, South Wales NP44 3AW, United Kingdom<br />
Tel: +44 (0)1633 628500 • Fax: +44 (0)1633 866346<br />
E-mail: sales@fulleon.co.uk • Website: www.cooperfulleon.com<br />
Quality System Cert. No. 378 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of alarm sounders, beacons and manually activated signalling devices.<br />
20 Nov 2011 553
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Cooper Lighting and Safety Limited<br />
Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom<br />
Tel: +44 (0)1302 303303 • Fax: +44 (0)1302 367155<br />
E-mail: sales@cooper-ls.com • Website: www.cooper-Is.com<br />
Quality System Cert. No. 714 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm panels.<br />
Core Industrial Plastics Limited<br />
Unit 12, A1 Ferrybridge Business Park, Fishergate, Knottingley, West Yorkshire WF11 8NA, United Kingdom<br />
Tel: +44 (0)1977 676072 • Fax: +44 (0)1977 676069<br />
E-mail: sales@coreplastics.co.uk<br />
Quality System Cert. No. 803 Assessed to ISO 9001:2008<br />
Scope:<br />
Procurement and supply of printed FR board.<br />
Corus Panels and Profiles<br />
Shotton Works, Flintshire CH5 2NH, United Kingdom<br />
Tel: +44 (0)1684 856600 • Fax: +44 (0)1684 856601<br />
E-mail: sales@coruspanelsandprofiles.co.uk • Website: www.coruspanelsandprofiles.com<br />
Quality System Cert. No. 460 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of metal-faced profiles, roof and wall cladding, composite flooring, composite panels, façade systems,<br />
rain screen systems, structural tray systems including ancillary items and flashings in accordance with client’s specified requirements.<br />
Cranford Controls Limited<br />
Unit 2, Waterbrook Estate, Waterbrook Road, Alton, Hampshire GU34 2UD, United Kingdom<br />
Tel: +44 (0)1420 592444 • Fax: +44 (0)1420 592445<br />
E-mail: sales@cranfordcontrols.com • Website: www.cranfordcontrols.com<br />
Quality System Cert. No. 546 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, supply and manufacture of fire detection and alarm system accessories.<br />
Crawford UK Limited<br />
7 Churchill Way, 35A Business Park, Chapeltown, Sheffield, South Yorkshire S35 2PY, United Kingdom<br />
Tel: +44 (0)870 609 4474 • Fax: +44 (0)114 257 4397<br />
E-mail: sales.uk@crawfordsolutions.com • Website: www.crawfordsolutions.uk.com<br />
Quality System Cert. No. 001 Assessed to ISO 9001:2008<br />
Scope:<br />
Supply, installation, maintenance and repair of industrial doors and loading bay equipment.<br />
Service Centres:<br />
Central & Southern UK:<br />
7 Churchill Way, 35A Business Park, Chapeltown, Sheffield, South Yorkshire S35 2PY<br />
Tel: +44 (0)870 609 4474 • Fax: +44 (0)114 257 4397<br />
554 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Email: service.uk@crawfordsolutions.com • Website: www.crawfordsolutions.uk.com<br />
Northern UK:<br />
First Floor, Cedar House, Quarry Court, Livingston, West Lothian EH54 6AX<br />
Tel: +44 (0)1506 417237 • Fax: +44 (0)1506 412726<br />
Email: service.uk@crawfordsolutions.com • Website: www.crawfordsolutions.uk.com<br />
Out of office hours: Tel.: +44 (0)1244 355235<br />
New Product Sales & Installation:<br />
Contact Details:<br />
7 Churchill Way, 35A Business Park, Chapeltown, Sheffield, South Yorkshire S35 2PY<br />
Tel: +44 (0)114 257 4330 • Fax: +44 (0)114 257 4399<br />
Certificate No. 001 Assessed to ISO 9001:2008<br />
Scope:<br />
Supply and installation of industrial doors and loading bay equipment.<br />
CTM Fire and Security Limited (Leyland & London Offices)<br />
Unit 2, Osprey Place, Moss Side Industrial Estate, Leyland PR26 7EW, United Kingdom<br />
Tel: +44 (0)800 5872753 • Fax: +44 (0)1772 641227<br />
E-mail: ctmfire@btconnect.com • Website: www.firealarmuk.com<br />
Including satellite office at:<br />
BBC Television Centre, Arch 118, Dodds Yard, Wood Lane, London W12 7RJ, United Kingdom<br />
Quality System Cert. No. 710 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, supply, installation, commissioning and servicing of fire detection and alarm systems. Installation, service of portable fire<br />
extinguishers.<br />
Culimeta-Saveguard Limited<br />
Tame Valley Mill, Wainwright Street, Dukinfield, Cheshire SK16 5NB, United Kingdom<br />
Tel: +44 (0)161 344 2484 • Fax: +44 (0)161 344 2486<br />
E-mail: sales@saveguard.com<br />
Quality System Cert. No. 552 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of cavity fore barriers and related fire protection products, protective textiles, thermal and accoustic<br />
insulation.<br />
D.I.S. Sprinklers<br />
183 Westgate Street, Gloucester GL1 2RN, United Kingdom<br />
Tel: +44 (0)1452 304927 • Fax: +44 (0)1452 306692<br />
E-mail: sprinklers@dis-ltd.co.uk • Website: www.dis-ltd.co.uk<br />
Quality System Cert. No. 286 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
20 Nov 2011 555
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Daemon Fire and Security Limited<br />
Daemon House, 41-42 Albert Road, Tamworth, Staffs B79 7JS, United Kingdom<br />
Tel: +44 (0)1827 69266 • Fax: +44 (0)1827 53584<br />
E-mail: sales@daemonfire.co.uk<br />
Quality System Cert. No. 542 Assessed to ISO 9001:2008<br />
Scope:<br />
Installation, commissioning and servicing of fire detection and alarm systems.<br />
Dalen Limited<br />
Valepits Road, Garretts Green Industrial Estate, Birmingham B33 0TD, United Kingdom<br />
Tel: +44 (0)121 783 3838 • Fax: +44 (0)121 784 6348<br />
E-mail: sales@top-tec.co.uk • Website: www.top-tec.co.uk<br />
Quality System Cert. No. 276 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of physical security devices, computer and TV stands, materials handling and storage equipment, access platforms and<br />
general metal fabrication and powder coating services.<br />
Datatag ID Limited<br />
3000 Hillswood Drive, Hillswood Business Park, Chertsey, Surrey KT16 0RS, United Kingdom<br />
Tel: +44 (0)1932 895304 • Fax: +44 (0)1932 796797<br />
E-mail: info@datatag.co.uk • Website: www.datatag.co.uk<br />
24/7 Telephone Number: 0845 0700 440<br />
Quality System Cert. No. 665 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and distribution of asset identification systems and provision of secure database registration services.<br />
Dätwyler Cables<br />
Unit of Dätwyler Switzerland Inc, Gotthardstrasse 31, CH-6460 Altdorf, Switzerland<br />
Tel: +41 41 875 1122 • Fax: +41 41 875 1860<br />
E-mail: info.ch@daetwyler-cables.com • Website: www.daetwyler-cables.com<br />
Quality System Cert. No. 172 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of electric cables for use in fire alarm installations.<br />
Day-Impex Limited<br />
Station Works, Earls Colne, Colchester, Essex CO6 2ER, United Kingdom<br />
Tel: +44 (0)1787 223232 • Fax: +44 (0)1787 224171<br />
E-mail: grahaml@day-impex.co.uk • Website: www.day-impex.co.uk<br />
Quality System Cert. No. 291 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of glass bulbs for fire sprinklers.<br />
556 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Debro Engineering and Presswork trading as Unistrut Ltd<br />
Unit 2 Delta Point Trading Estate, Greets Green Road, West Bromwich, West Midlands B70 9PL, United<br />
Kingdom<br />
Tel: +44 (0)121 580 6350 • Fax: +44 (0)121 580 6364<br />
Website: www.unistrut.co.uk<br />
Quality System Cert. No. 015 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of brackets and pipe support equipment.<br />
Defensor Group Limited<br />
Defensor House, 15 Kingsley Street, Leicester LE2 6DY, United Kingdom<br />
Tel: +44 (0)116 244 8689 • Fax: +44 (0)116 244 8884<br />
E-mail: j.kyte@defensorfds.co.uk<br />
Quality System Cert. No. 788 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning, service and maintenance of fire detection and alarm systems.<br />
Delta Extinctors S. A.<br />
Birmingham Street 102, Brussels 1070, Belgium<br />
Tel: +32 (0) 2 528 08 70 • Fax: +32 (0) 2 521 07 31<br />
E-mail: info@delta.be • Website: www.delta.be<br />
Quality System Cert. No. 910 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of portable 1kg, 2kg & 3kg (BC & ABC powder) extinguishers in accordance with EN 3.<br />
Design & Supply Limited<br />
13 Pant Industrial Estate, Merthyr Tydfil, Mid Glamorgan CF48 2SR, United Kingdom<br />
Tel: +44 (0)1685 350114 • Fax: +44 (0)1685 723276<br />
E-mail: dsl@designandsupply.co.uk<br />
Quality System Cert. No. 694 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of steel hinged door sets.<br />
Dewey Waters Limited<br />
Heritage Works, Winterstoke Road, Weston-Super-Mare, Somerset BS24 9AN, United Kingdom<br />
Tel: +44 (0)1934 421477 • Fax: +44 (0)1934 421488<br />
E-mail: sales@deweywaters.co.uk • Website: www.deweywaters.co.uk<br />
Quality System Cert. No. 135 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of GRP <strong>section</strong>al and one-piece tanks, and industrial and commercial mouldings.<br />
20 Nov 2011 557
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Digital Lighting (Dongguan) Co Ltd<br />
Xinmin Road, Xinmin District, Chang'an Town, Dongguan City, Guandong Province, China<br />
Tel: +86 769 5332372 • Fax: +86 769 5538520<br />
E-mail: info@dl-sv.com • Website: www.dl-sv.com<br />
Quality System Cert. No. 685 Assessed to ISO 9001:2008<br />
Scope:<br />
The design and manufacture of fire detection and alarm system components.<br />
Doncaster Cables<br />
Millfields Industrial Estate, Arksey Lane, Bentley, Doncaster, South Yorkshire DN5 0SJ, United Kingdom<br />
Tel: +44 (0)1302 821700 • Fax: +44 (0)1302 821701<br />
E-mail: sales@doncastercables.com • Website: www.doncastercables.com<br />
Quality System Cert. No. 338 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of electric cables for use in installations that require safety in the event of fire.<br />
Dong-A Flexible Metal Tubes Co. Ltd.<br />
4F Kowon Bldg. 20-19, Yangjae-Dong, Seocho-Gu, Seoul 137-888, Korea, Republic Of<br />
Tel: +82 (0)2 3476 2541 • Fax: +82 (0)2 3476 2540<br />
E-mail: daflex@daflex.co.kr<br />
Also at:<br />
#412-2 Chubook-Ri, Yangji-Myon, Yongin-Si, Gyeonggi-Do 449-822, Korea, Republic Of<br />
Quality System Cert. No. 565 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of flexible hoses for sprinkler systems, flexible tubing for gas supplies and water supplies, uncoated or plastic<br />
coated.<br />
DoorTechnik<br />
Moor Lane, Thorpe-on-the-Hill, Lincoln LN6 9BW, United Kingdom<br />
Tel: +44 (0)1522 693522 • Fax: +44 (0)1522 508494<br />
Website: www.doortechnik.co.uk<br />
Quality System Cert. No. 1084 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, installation and repair of fabricated products including general fabrication and metal based <strong>part</strong>s of a non-structural<br />
nature.<br />
Draka UK Limited<br />
Alfreton Road, Derby DE21 4AE, United Kingdom<br />
Tel: +44 (0)1332 345431 • Fax: +44 (0)1332 331237<br />
E-mail: firetuf@drakauk.com • Website: www.drakauk.com<br />
Quality System Cert. No. 361 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of electric cables for use in installations that require safety in the event of fire.<br />
558 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
DS SMITH CORREX (Trading as a division of DS Smith Plastics Limited)<br />
Madleaze Industrial Estate, Bristol Road, Gloucester GL1 5SG, United Kingdom<br />
Tel: +44 (0)1452 316500 • Fax: +44 (0)1452 300436<br />
E-mail: sales@kayplast.com • Website: www.kaysersberg-plastics.com<br />
Quality System Cert. No. 227 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and development of plastics packaging and other products using thermoforming, injection moulding and structural foam, and<br />
conversion of structural sheet material. Manufacture of structural sheet and conversion into packaging and other products including flame<br />
retardant materials.<br />
Dubai Cable Company (Private) Limited, Trading as Ducab<br />
Old Abu Dhabi Road, Jebel Ali, Dubai, United Arab Emirates<br />
Tel: +9714 808 2500 • Fax: +9714 808 2622<br />
E-mail: ducab@ducab.com • Website: www.ducab.com, Sales office: PO Box 11529, Dubai, UAE<br />
Quality System Cert. No. 781 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of electric cables for installations that require safety in the event of fire.<br />
Dubai Cable Company (Private) Limited, Trading as Ducab<br />
Ducab-M1, Plot No. - 2D12,3D2,4D2,5D2, Sector - M41, Industrial City of Abu Dhabi-1, Mussafah, Abu Dhabi,<br />
United Arab Emirates<br />
Tel: +9714 808 2500 • Fax: +9714 808 2622<br />
E-mail: ducab@ducab.com • Website: www.ducab.com<br />
Quality System Cert. No. 782 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of electric cables for installations that require safety in the event of fire.<br />
Dudley Safes Limited<br />
Unit 17 Deepdale Works, Deepdale Lane, Upper Gornal, Dudley, West Midlands DY3 2AF, United Kingdom<br />
Tel: +44 (0)1384 239991 • Fax: +44 (0)1384 455129<br />
Website: www.dudleysafes.com<br />
Quality System Cert. No. 304 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of free-standing safes.<br />
Duplus Architectural Systems Limited<br />
370 Melton Road, Leicester LE4 7SL, United Kingdom<br />
Tel: +44 (0)116 2610710 • Fax: +44(0)116 2610539<br />
E-mail: sales@duplus.co.uk • Website: www.duplus.co.uk<br />
Quality System Cert. No. 1048 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Fabrication and installation of aluminium windows, doors and curtain walling.<br />
20 Nov 2011 559
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
EMCOR Facilities Services Limited, EMCOR Specialist Services<br />
Premier House, Tollgate, Eastleigh, Hampshire SO53 3YE, United Kingdom<br />
Tel: +44 (0)2380 648028 • Fax: +44 (0)2380 648191<br />
E-mail: david.parker@emcoruk.com<br />
Quality System Cert. No. 620 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning, service and repair of fire detection and alarm systems.<br />
Emirates Fire Fighting Equipment Factory L.L.C. (FIREX)<br />
P.O.Box 22436, Industrial Area 13, Sharjah, United Arab Emirates<br />
Tel: +971 6 5340300 • Fax: +971 6 5340090<br />
E-mail: firex@emirates.net.ae • Website: www.firexuae.com<br />
Quality System Cert. No. 863 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of fire cabinets, fire hose reels and wheeled unit fire extinguishers. Distribution of portable fire extinguishers and fire<br />
blankets. Design and installation of fire sprinkler systems, fire alarm systems and fire fighting systems. Distribution of landing valves and<br />
breech inlets. Design, manufacture and distribution of breech inlet cabinets. Manufacture of fire doors.<br />
Envirowrap Solutions Limited<br />
Registered Office:, Strangford House, Church Road, Ashford, Kent TN23 3QR, United Kingdom<br />
Tel: +44 (0)1233 860080 • Fax: +44 (0)1233 860090<br />
E-mail: enquiries@envirowrap.info • Website: www.envirowrap.info<br />
Quality System Cert. No. 691 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, supply, distribution and installation of EnviroWrap flame retardant sheeting including the control of a sub contract manufacturing<br />
process.<br />
Essex Safety Glass Limited<br />
Units 1-3, Moss Road, Witham, Essex CM8 3UG, United Kingdom<br />
Tel: +44 (0)1376 520061 • Fax: +44 (0)1376 521176<br />
E-mail: sales@esguk.co.uk • Website: www.esguk.co.uk<br />
Quality System Cert. No. 997 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of security rated and bullet resistant glass.<br />
560 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Eton Fire Limited<br />
Printers Gate, Limehouse Court, 3 - 11 Dod Street, London E14 7EQ, United Kingdom<br />
Tel: +44 (0)207 517 6300 • Fax: +44 (0)207 538 5231<br />
E-mail: fire@etonfire.com • Website: www.etonfire.com<br />
Also at:<br />
Aynsley House, Waterside Business Centre, Wolverhampton Road, Cannock WS11 1SN, United Kingdom<br />
Tel: +44 (0)1543 431 340 • Fax: +44 (0)1543 571 680<br />
E-mail: fire@etonfire.com • Website: www.etonfire.com<br />
Quality System Cert. No. 662 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Eurobond Laminates Limited & Eurobond Doors Limited<br />
Wentloog Corporate Park, Wentloog, Cardiff CF3 2ER, United Kingdom<br />
Tel: + 44 (0)2920 776677 • Fax: + 44 (0)2920 369161<br />
E-mail: sales@eurobond.co.uk • Website: www.eurobond.co.uk<br />
Eurobond Doors Limited<br />
Tel: +44 (0)29 20 36 11 11 • Fax: +44 (0)29 20 36 22 22<br />
E-mail: sales@eurobonddoors.co.uk<br />
Eurobond Laminates Limited<br />
Tel: +44 (0)2920 77 66 77 • Fax: +44 (0)2920 36 91 61<br />
E-mail: sales@eurobond.co.uk<br />
Quality System Cert. No. 545 Assessed to ISO 9001:2008<br />
Scope:<br />
Certificates 523 (Eurobond Doors Limited) and 545 (Eurobond Laminates Limited) have been merged and the scope is as follows:-<br />
Design, manufacture and supply of structural insulated panels, industrial doors, flashings and ancillaries.<br />
Euroclad Limited<br />
Wentloog Corporate Park, Wentloog Road, Cardiff CF3 2ER, United Kingdom<br />
Tel: +44 (0)2920 790722 • Fax: +44 (0)2920 793149<br />
E-mail: sales@euroclad.com • Website: www.euroclad.com<br />
Quality System Cert. No. 879 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of elite 1.25RW built-up roof and elite 55.30RW built-up wall rockfibre insulation plus elite 3.16GW built-up roof & elite 51.30<br />
built-up wall with glass wool insulation to LPS 1181 Part 1: Issue 1.<br />
20 Nov 2011 561
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Everday Technology Co. Limited<br />
No 8, Lane 492, Ba-Der Street, Shulin 238, Taipei Hsien, Taiwan ROC<br />
Tel: +886 2 2668 9668 • Fax: +886 2 2668 9666<br />
E-mail: tech@everday.com • Website: www.everday.com<br />
Quality System Cert. No. 512 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of smoke, heat, carbon monoxide, and gas detectors.<br />
Excel Industries Ltd<br />
Maerdy Industrial Estate (South), Rhymney, Gwent NP22 5PY, United Kingdom<br />
Tel: +44 (0)1685 845200 • Fax: +44 (0)1685 844106<br />
E-mail: info@excelfibre.com • Website: www.excelfibre.com<br />
Quality System Cert. No. 721 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of Warmcel Panel Systems.<br />
Eyston Company Ltd<br />
27 Zhen Tian South Road, Wei Xing Industrial Zone, Yan Tian, Feng Gang, Dongguan, Guangdong, China<br />
Tel: +852 25573135 • Fax: +852 28970249<br />
E-mail: tracylo@eyston.com • Website: www.eyston.com<br />
Quality System Cert. No. 679 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of smoke detectors.<br />
F.V.S. Limited<br />
Broom Street, Off Huddersfield Road, Newhey, Rochdale OL16 3RY, United Kingdom<br />
Tel: +44 (0)1706 848599 • Fax: +44 (0)1706 843474<br />
E-mail: fvs@fvslimited.co.uk • Website: www.fvslimited.co.uk<br />
Quality System Cert. No. 151 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems. Fabrication of pipework for fire sprinkler systems.<br />
Fendor Limited<br />
Heworth House, William Street, Felling, Gateshead NE10 0JP, United Kingdom<br />
Tel: +44 (0)191 438 3222 • Fax: +44 (0)191 438 1686<br />
E-mail: av@fendor.co.uk • Website: www.fendor.co.uk<br />
Quality System Cert. No. 712 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of specialist glazing systems.<br />
562 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
FES Limited, FES Sprinklers<br />
Forth House, Pirnhall Business Park, Stirling FK7 8HW, United Kingdom<br />
Tel: +44 (0)1786 819600 • Fax: +44 (0)1786 811456<br />
E-mail: hq@fes.ltd.uk<br />
Quality System Cert. No. 853 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning and servicing of sprinklers systems.<br />
FFE Fire & Security Limited<br />
122 The Minories, London EC3 1NT, United Kingdom<br />
Tel: +44 (0)845 60 999 06 • Fax: +44 (0)20 8665 4125<br />
E-mail: enquiries@ffe.co.uk • Website: www.ffe.co.uk<br />
Quality System Cert. No. 625 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning, repair and servicing of fire detection and alarm systems.<br />
Fike Safety Technology Ltd<br />
Unit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United Kingdom<br />
Tel: +44 (0)1633 865558 • Fax: +44 (0)1633 866656<br />
E-mail: fstinfo@fike.com • Website: www.fikesafetytechnology.co.uk<br />
Quality System Cert. No. 331 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire alarm, detection and indicating equipment.<br />
Filling and Packing Materials Manufacturing Company (F.I.P.C.O.)<br />
P.O. Box 8762, Riyadh 11492, Kingdom of Saudi Arabia<br />
Tel: +966 1265 2299 • Fax: +966 1265 1275<br />
Quality System Cert. No. 871 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of woven coated polypropylene sheets (in rolls) to flame retardant standard LPS 1207.<br />
Fire Alarm Solutions Limited<br />
Unit 2, Manor Way Business Centre, Fairview Industrial Park, Marsh Way, Rainham, Essex RM13 8UG,<br />
United Kingdom<br />
Tel: +44(0) 1708 521181 • Fax: +44(0) 1708 521182<br />
E-mail: enquiries@fas-ltd.com • Website: www.fas-ltd.com<br />
Quality System Cert. No. 972 Assessed to ISO 9001:2008<br />
Scope:<br />
Sprinkler system design and project management.<br />
20 Nov 2011 563
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Fire Defence (Northern) Limited<br />
Unit 9, B.B.I.C. Innovation Way, Wilthorpe, Barnsley, South Yorkshire S75 1JL, United Kingdom<br />
Tel: +44 (0)1226 289558 • Fax: +44 (0)1226 249625<br />
E-mail: fds@fire-defence.com • Website: www.fire-defence.com<br />
Quality System Cert. No. 1053 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Fire Defence plc<br />
Crown Yealm House, Pathfields Business Park, South Molton EX36 3LH, United Kingdom<br />
Tel: +44 (0)1769 574070 • Fax: +44 (0)1769 574079<br />
E-mail: fds@fire-defence.com • Website: www.fire-defence.com<br />
Quality System Cert. No. 245 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Fire Logistics Limited<br />
Unit A4, Union Street, Shieldfield, Newcastle upon Tyne NE2 1AH, United Kingdom<br />
Tel: +44 (0)191 230 3647 • Fax: +44 (0)191 230 3650<br />
E-mail: enquiries@firelogistics.co.uk • Website: www.firelogistics.co.uk<br />
Quality System Cert. No. 872 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, supply, installation and servicing of fire sprinkler systems.<br />
Fire Protection Limited<br />
Flamebar House, South Road, Templefields, Harlow, Essex CM20 2AR, United Kingdom<br />
Tel: +44 (0)1279 634 230 • Fax: +44 (0)1279 634 231<br />
E-mail: info@fireprotection.co.uk • Website: www.fireprotection.co.uk<br />
Quality System Cert. No. 277 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of fire resistant ductwork systems and penetration seals.<br />
Fire Queen Limited<br />
23-37 Broadstone Road, Reddish, Stockport, Cheshire SK5 7AR, United Kingdom<br />
Tel: +44 (0)800 731 2748 • Fax: +44 (0)161 442 2664<br />
E-mail: enquiries@firequeen.co.uk • Website: www.firequeen.co.uk<br />
Quality System Cert. No. 489 Assessed to ISO 9001:2008<br />
Scope:<br />
Supply, installation and servicing of portable fire extinguishers and fire hose reels. Supply and installation of fire safety notices.<br />
564 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Fire Security (Sprinkler Installations) Limited<br />
Homefield Road, Haverhill, Suffolk CB9 8QP, United Kingdom<br />
Tel: +44 (0)1440 705815 • Fax: +44 (0)1440 704352<br />
E-mail: info@firesecurity.co.uk • Website: www.firesecurity.co.uk<br />
Quality System Cert. No. 144 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler and water spray systems. Fabrication of pipework for fire sprinkler systems.<br />
Fireproof Fire Engineering Limited<br />
The Old Brewery, 40 Coldhurst Street, Oldham, Lancashire OL1 2BQ, United Kingdom<br />
Tel: +44 (0)161 620 0902 • Fax: +44 (0)161 620 0772<br />
E-mail: contactus@fireproofsprinklersystems.com • Website: www.fireproofsprinklersystems.com<br />
Quality System Cert. No. 058 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler and water spray systems.<br />
Firespray International Limited<br />
Flamebar House, South Road, Templefields, Harlow, Essex CM20 2AR, United Kingdom<br />
Tel: +44 (0)1279 634 230 • Fax: +44 (0)1279 634 232<br />
E-mail: info@firespray.eu.com • Website: www.firespray.eu.com<br />
Quality System Cert. No. 415 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of fire resistant ductwork systems and penetration seals.<br />
Firetecnics Systems Limited<br />
142 Vauxhall Street, London SE11 5RH, United Kingdom<br />
Tel: +44 (0) 20 7587 0927 • Fax: +44 (0) 20 7582 3496<br />
E-mail: info@firetecnics.co.uk • Website: www.firetecnics.com<br />
Quality System Cert. No. 555 Assessed to ISO 9001:2008<br />
Scope:<br />
Installation, commissioning and servicing of fire detection and alarm systems.<br />
First Fire Protection Limited<br />
Unit 3, Network 4, Lincoln Road, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3RF,<br />
United Kingdom<br />
Tel: +44 (0)1494 522031/2 • Fax: +44 (0)1494 452752<br />
E-mail: enquiries@firstfireprotection.co.uk • Website: www.firstfireprotection.co.uk<br />
Quality System Cert. No. 158 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
20 Nov 2011 565
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Flameshield Products Limited (Incorporating Flameshield Limited)<br />
4 The Limes, Ingatestone, Essex CM4 0BE, United Kingdom<br />
Tel: +44 (0)1277 352202 • Fax: +44 (0)1277 355419<br />
E-mail: info@flameshield.org • Website: www.flameshield.org<br />
Quality System Cert. No. 785 Assessed to ISO 9001:2008<br />
Scope:<br />
The operation of licensed manufacturing agreement(s) to manufacture - Flameshield Products Ltd, fire resistant ductwork systems and<br />
the supervision of the licensees FPC management system(s).<br />
The operation of a licensed installer service to - inspect and certify Flameshield Products Ltd, fire resistant ductwork system(s)<br />
installations. The supply and installation of Flameshield Products Ltd - fire resistant ductwork systems.<br />
Flexiform Business Furniture Limited-incorporating Asgard Secure Steel Storage<br />
1392 Leeds Road, Bradford, West Yorkshire BD3 7AE, United Kingdom<br />
Tel: +44 (0)1274 706206 • Fax: +44 (0)1274 660867<br />
E-mail: info@flexiform.co.uk • Website: www.flexiform.co.uk<br />
Quality System Cert. No. 596 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of business furniture and secure storage units.<br />
Fortress Doors N.I. Limited<br />
6 Trench Road, Hyde Park Industrial Estate, Newtownabbey, Belfast, Northern Ireland BT36 4TY, United<br />
Kingdom<br />
Tel: +44 (0)28 9034 2655 • Fax: +44 (0)28 9034 2651<br />
E-mail: grodgers@fortaxa.com • Website: www.fortaxa.com<br />
Quality System Cert. No. 1076 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of fire and security doors and roller shutters.<br />
Franklin Hodge Industries Ltd.<br />
Jubilee Building, Faraday Road, Westfields Trading Estate, Hereford HR4 9NS, United Kingdom<br />
Tel: +44 (0)1432 269605 • Fax: +44 (0)1432 277454<br />
E-mail: sales@franklinhodge.com • Website: www.franklinhodge.com<br />
Quality System Cert. No. 037 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of water storage tanks, tank refurbishment and maintenance.<br />
Galglass Limited<br />
321 Hough Lane, Wombwell, Barnsley, South Yorkshire S73 0LR, United Kingdom<br />
Tel: +44 (0)1226 340370 • Fax: +44 (0)1226 344200<br />
E-mail: sales@galglass.co.uk • Website: www.galglass.com<br />
Quality System Cert. No. 108 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of cylindrical and rectangular water storage tanks.<br />
566 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Gaocheng General Foundry<br />
Yucai Road, Gaocheng City, Hebei Province, China<br />
Tel: +86 311 8816 6123 • Fax: +86 311 8819 3601<br />
E-mail: ixgzzc@163.net<br />
Quality System Cert. No. 920 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and machining of grey and ductile iron castings.<br />
Globe Fire Sprinkler Corporation<br />
4077 Air Park Drive, Standish, Michigan 48658, United States<br />
Tel: +1 989 846 4583 • Fax: +1 989 846 9231<br />
Website: www.globesprinkler.com<br />
Quality System Cert. No. 147 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire sprinklers, fire protection valves, and related products for fire sprinkler systems.<br />
Gloucester Composites Limited<br />
Fox House, Stonedale Road, Stonedale, Gloucestershire GL10 3SA, United Kingdom<br />
Tel: +44 (0)1453 791616 • Fax: +44 (0)1453 791516<br />
E-mail: sales@gloucestercomposites.com • Website: www.gloucestercomposites.com<br />
Quality System Cert. No. 773 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of <strong>section</strong>al water tanks and a range of hot pressed SMC moulded products.<br />
Godwin Pumps Limited<br />
Quenington, Cirencester, Gloucestershire GL7 5BX, United Kingdom<br />
Tel: +44 (0)1285 750271 • Fax: +44 (0)1285 750352<br />
E-mail: sales@godwinpumps.co.uk • Website: www.godwinpumps.co.uk<br />
Quality System Cert. No. 1027 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, commissioning and service of centrifugal pumping equipment, system packages and fire pumps.<br />
Goran Plastics<br />
Unit C, 5 Caxton Way, Watford Business Park, Watford, Herts WD18 8UA, United Kingdom<br />
Tel: +44 (0)1923 255700 • Fax: +44 (0)1923 255698<br />
E-mail: sales@goran.co.uk<br />
Quality System Cert. No. 688 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of twinwall polypropylene sheeting.<br />
20 Nov 2011 567
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Gordonson Fire Protection Limited<br />
Unit 8, Bombay Street, Bermondsey, London SE16 3UX, United Kingdom<br />
Tel: +44 (0)207 237 6707 • Fax: +44 (0)207 252 0152<br />
E-mail: gordonson@mailbox.co.uk<br />
Quality System Cert. No. 323 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Grange Door Systems<br />
Unit 12, Bilston Glen Industrial Estate, Edinburgh EH20 9LZ, United Kingdom<br />
Tel: +44 (0)131 440 7000 • Fax: +44 (0)131 440 7003<br />
E-mail: admin@grangedoor.com • Website: www.grangedoor.com<br />
Quality System Cert. No. 573 Assessed to ISO 9001:2008<br />
Scope:<br />
Installation, servicing and repair of industrial doors, fire doors and fire rolling shutters.<br />
Grundfos Fire Systems<br />
Ferryboat Lane, Castletown, Sunderland SR5 3JL, United Kingdom<br />
Tel: +44 (0)191 549 5555 • Fax: +44 (0)191 516 0067<br />
Website: www.grundfos.co.uk<br />
Quality System Cert. No. 510 Assessed to ISO 9001:2008<br />
Scope:<br />
Sales, manufacture and test of fire pumps and fire pump sets.<br />
Grundfos Europump Limited<br />
Oxford Court, Greenfold Way, Leigh, Lamcashire WN7 3XJ UK<br />
Scope:<br />
Installation, commissioning, service and repair of fire pumps and pump / sets.<br />
gte Brandschutz AG<br />
Hamburger Straße 2, D-14532 Stahnsdorf, Germany<br />
Tel: +49 3329 6359-0 • Fax: +49 3329 6359-25<br />
E-mail: gte@gte.ag • Website: www.gte.ag<br />
Quality System Cert. No. 735 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, installation, service and repair of gte conveyor shutters.<br />
Gulf Security Technology Co. Ltd - A UTC Fire & Security Company<br />
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province<br />
066004, China<br />
Tel: +86 0335 8502528 • Fax: +86 0335 8508942<br />
E-mail: gst@gst.com.cn • Website: www.gst.com.cn<br />
Quality System Cert. No. 548 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm systems and components.<br />
568 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Guthrie Douglas Limited<br />
12 Heathcote Way, Heathcote Industrial Estate, Warwick CV34 6TE, United Kingdom<br />
Tel: +44 (0)1926 452452 • Fax: +44 (0)1926 336417<br />
E-mail: info@guthriedouglas.com • Website: www.guthriedouglas.com<br />
Quality System Cert. No. 193 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and repair of drive and control systems for building automation including access and security systems, fire, smoke<br />
and solar protection equipment.<br />
GW Sprinkler A/S<br />
Kastanievej 15, DK-5620 Glamsbjerg, Denmark<br />
Tel: +45 64 72 2055 • Fax: +45 64 72 2255<br />
E-mail: sales.dep@gwsprinkler.com<br />
Quality System Cert. No. 084 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire sprinklers, fire protection valves and related products for fire sprinkler systems.<br />
H S Jackson & Son (Fencing) Limited, t/a Jacksons Fencing<br />
Stowting Common, Ashford, Kent TN25 6BN, United Kingdom<br />
Tel: +44 (0)1233 750393 • Fax: +44 (0)1233 750178<br />
E-mail: security@jacksons-fencing.co.uk • Website: www.jacksons-fencing.co.uk<br />
Quality System Cert. No. 913 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, supply and installation of timber and steel, fencing, gate and security barriers to commercial, trade and domestic<br />
customers.<br />
The following location is included within the above scope of certification:-<br />
Ashford<br />
Stowting Common, Ashford, Kent TN25 6BN<br />
Tel: +44 (0)1233 750393 • Fax: +44 (0)1233 750178<br />
Scope:<br />
Manufacture, supply and installation of timber and steel, fencing, gate and security barriers to commercial, trade and domestic customers.<br />
The following locations are included within the above scope of certification:-<br />
Bath<br />
New Rock, Chilcompton, Radstock, Bath BA3 4GJ<br />
Tel: +44 (0)1761 232666 • Fax: +44 (0)1761 232647<br />
Chester<br />
Dragon Hall, Whitchurch Road, Chowley, Tattenhall, Chester CH3 9DU<br />
Tel: +44 (0)1829 770776 • Fax: +44 (0)1829 770778<br />
20 Nov 2011 569
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Haes Systems Limited<br />
Columbia House, Packet Boat Lane, Cowley Peachey, Uxbridge, Middlesex UB8 2JP, United Kingdom<br />
Tel: +44 (0)1895 422066 • Fax: +44 (0)1895 420603<br />
E-mail: enquiries@haes-systems.co.uk • Website: www.haes-systems.co.uk<br />
Quality System Cert. No. 810 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of fire detection and alarm system components.<br />
Hall & Kay Fire Engineering (Manchester)<br />
10 Westpoint, Clarence Avenue, Trafford Park, Manchester M17 1QS, United Kingdom<br />
Tel: +44 (0)161 872 7316 • Fax: +44 (0)161 872 7003<br />
E-mail: Manchester@hkfire.co.uk • Website: www.hkfire.co.uk<br />
Quality System Cert. No. 139 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Hall & Kay Fire Engineering (Paisley)<br />
Studio 3002, Abbey Mill, Seedhill Road, Paisley PA1 1TJ, United Kingdom<br />
Tel: +44 (0)141 887 4921 • Fax: +44 (0)141 887 6346<br />
E-mail: glasgow@hkfire.co.uk • Website: www.hkfire.co.uk<br />
Quality System Cert. No. 771 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Hall & Kay Fire Engineering (Thame)<br />
Thame Park Road, Thame, Oxfordshire OX9 3RT, United Kingdom<br />
Tel: +44(0) 1844 265008 • Fax: +44(0) 1844 265008<br />
E-mail: detection@hkfire.co.uk • Website: www.hkfire.co.uk<br />
Quality System Cert. No. 907 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning & servicing of fire detection, fire alarm and gaseous fire extinguishing systems.<br />
Hall & Kay Fire Engineering (West Midlands)<br />
Sterling Park, Clapgate Lane, Woodgate Valley, West Midlands B32 3BU, United Kingdom<br />
Tel: +44 (0)121 421 3311 • Fax: +44 (0)121 422 7312<br />
E-mail: birmingham@hkfire.co.uk • Website: www.hkfire.co.uk<br />
Quality System Cert. No. 036 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and servicing of fire sprinklers, alarm, dry and deluge valves and related products for fire sprinkler systems.<br />
570 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Hall Fire Protection Limited<br />
Holloway Drive, Wardley Business Park, Worsley M28 2LA, United Kingdom<br />
Tel: +44 (0)161 793 4822 • Fax: +44 (0)161 794 4950<br />
E-mail: sales@hallfire.co.uk • Website: www.hallfire.co.uk<br />
Quality System Cert. No. 027 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler and water spray systems. Fabrication of pipework for fire sprinkler systems.<br />
Hallmark Fire (a division of SFS Fire Services Ltd)<br />
Systems House, Stoke Road, Hoo, Rochester, Kent ME3 9NT, United Kingdom<br />
Tel: +44 (0)8700 111150 • Fax: +44 (0)8700 111160<br />
E-mail: sales@hallmarkfire.co.uk • Website: www.hallmarkfire.co.uk<br />
Quality System Cert. No. 452 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning and servicing of fire detection systems, fire alarm systems and gaseous fire extinguishing systems.<br />
Halton Foodservice Limited<br />
11 Laker Road, Airport Industrial Estate, Rochester, Kent ME1 3QX, United Kingdom<br />
Tel: +44 (0)1634 666111 • Fax: +44 (0)1634 666333<br />
E-mail: kelly.hiley@halton.com • Website: www.halton.com/foodservice<br />
Quality System Cert. No. 996 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Design and manufacture of KSA Filters.<br />
Handan Boate Foundry Co Limited<br />
Foundry Industry Zone, Jize County, Handan, Hebei Province 057350, China<br />
Tel: +0310 766 2358 • Fax: +0310 766 2868<br />
E-mail: hd-baote@tom.com<br />
Quality System Cert. No. 921 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and machining of grey and ductile iron castings.<br />
Hart Door Systems<br />
Redburn Road, Westerhope Industrial Estate, Westerhope, Newcastle upon Tyne NE5 1PJ, United Kingdom<br />
Tel: +44 (0)191 214 0404 • Fax: +44 (0)191 271 1611<br />
E-mail: sales@speedor.co.uk • Website: www.speedor.com<br />
Quality System Cert. No. 016 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, development, manufacture, installation, service and repair of industrial doors, industrial rolling shutters, fire doors and fire rolling<br />
shutters.<br />
20 Nov 2011 571
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Harvel Plastics Incorporated (Bakersfield)<br />
7001 Schirra Court, Bakersfield, California 93313, United States<br />
Tel: +1 661 396 0653 • Fax: +1 661 396 1821<br />
E-mail: harvel@harvel.com • Website: www.harvel.com<br />
Quality System Cert. No. 455 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of PVC and CPVC pipes.<br />
Harvel Plastics Incorporated (Easton)<br />
300 Kuebler Road, Easton, Pennsylvania 18040, United States<br />
Tel: + 1 610 252 7355 • Fax: + 1 610 253 4436<br />
E-mail: harvel@harvel.com<br />
Quality System Cert. No. 270 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of PVC and CPVC pipe, shapes and ducts.<br />
Hemsec Manufacturing Limited<br />
Stoney Lane, Rainhill, Prescot, Merseyside L35 9LL, United Kingdom<br />
Tel: +44 (0)151 426 7171 • Fax: +44 (0)151 493 1331<br />
E-mail: sales@hemsec.com • Website: www.hemsec.com<br />
Quality System Cert. No. 558 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of thermal insulating and fire resistant composite panels.<br />
Henry Lewis and Sons (Wireworkers) Limited<br />
Unit 7, Bolling Road Industrial Estate, Bradford BD4 7HN, United Kingdom<br />
Tel: +44 (0) 1274 307359 • Fax: +44 (0) 1274 370784<br />
E-mail: info@henrylewisandson.co.uk • Website: www.henrylewisandson.co.uk<br />
Quality System Cert. No. 528 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture, assembly, installation and repair of physical security products, comprising retractable grilles, shutters, fencing and guards.<br />
Heras U.K. Fencing Systems<br />
Herons Way, Balby, Doncaster DN4 8WA, United Kingdom<br />
Tel: +44 (0)1302 364551 • Fax: +44 (0)1302 322401<br />
E-mail: enquiries@herasuk.co.uk • Website: www.heras.co.uk<br />
Quality System Cert. No. 890 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of security fencing systems.<br />
572 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Hersey Meters<br />
Highway 70, Cleveland (Rowan County), North Carolina 27013, United States<br />
Tel: +1 704 278 2221 • Fax: +1 704 278 9617<br />
Website: www.herseymeters.com<br />
Quality System Cert. No. 481 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of water meters and related waterworks products. Manufacture of butterfly valves and check valves.<br />
Hershey Valve Co Limited<br />
No 16 Jing 2nd Road, Wuchi, Taichung 435, Taiwan ROC<br />
Tel: +886 4 2659 5377 • Fax: +886 4 2659 5288<br />
Quality System Cert. No. 438 Assessed to ISO 9001:2008<br />
Scope:<br />
Production of CPVC, UPVC and plastic pipes, fittings, valves, sheets and cable trays.<br />
Hilti (Gt Britain) Limited<br />
1 Trafford Wharf Road, Manchester M17 1BY, United Kingdom<br />
Tel: +44 (0)161 886 1000 • Fax: +44 (0)161 872 1240<br />
Website: www.hilti.co.uk<br />
Freephone: 0800 886 100, Freefax: 0800 886 200<br />
Quality System Cert. No. 090 Assessed to ISO 9001:2008<br />
Scope:<br />
Stockholding and supply of fire penetration seals, sealants and fire rated foam filler.<br />
Hochiki America Corporation<br />
7051 Village Drive, Buena Park, California 90621, United States<br />
Tel: +1 714 522 2246 • Fax: +1 714 522 2268<br />
E-mail: sales@hochiki.com • Website: www.hochiki.com<br />
Quality System Cert. No. 358 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of fire detection and alarm system components. Procurement, distribution and repair of control indicating equipment for fire<br />
protection.<br />
Hochiki Corporation<br />
246 Tsuruma, Machidia, Tokyo 194-8577, Japan<br />
Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167<br />
E-mail: info@hochiki.co.jp • Website: www.hochiki.co.jp<br />
Also at:<br />
141-1 Maehara, Ejiri, Kakuda, Miyagi 981-1521, Japan<br />
Quality System Cert. No. 117 Assessed to ISO 9001:2008<br />
Scope:<br />
Machida:<br />
20 Nov 2011 573
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Design of fire and gas leakage alarms.<br />
Design and manufacture of fire detectors and fire control and indicating equipment.<br />
Design and manufacture control panels for road tunnels.<br />
Design and manufacture control panels for fire sprinkler systems.<br />
Control of outsourcing manufacture for emergency alarm equipment and alarm sounders.<br />
Design and manufacture of small power radio equipment.<br />
Scope:<br />
Miyagi<br />
Manufacture of point type smoke and heat detectors, optical beam smoke detectors and fire and gas leakage alarms.<br />
Control of outsourcing manufacture for emergency alarm equipment.<br />
Manufacture of small power radio equipment.<br />
Hochiki Europe (UK) Limited<br />
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom<br />
Tel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132<br />
E-mail: sales@hochikieurope.com<br />
Quality System Cert. No. 164 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, service and maintenance of fire detection and alarm equipment.<br />
Honeywell Life Safety Systems UK<br />
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom<br />
Tel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300<br />
E-mail: gent_enquiry@gent.co.uk • Website: www.gent.co.uk<br />
Quality System Cert. No. 042 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm systems and components.<br />
Honeywell Security UK Limited<br />
Newhouse Industrial Estate, Fire Exit 3, Motherwell, Lanarkshire ML1 5SB, United Kingdom<br />
Tel: +44 (0)1698 738200 • Fax: +44 (0)1698 738300<br />
E-mail: hsuk64salesteam@honeywell.com • Website: www.honeywell-security.co.uk<br />
Repair at:<br />
Aston Fields Road, Whitehouse Industrial Estate, Runcorn, Cheshire WA7 3DL, United Kingdom<br />
Quality System Cert. No. 787 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, repair and sales of intruder security products.<br />
Horing LIH Industrial Co Ltd<br />
No. 17-6, Ai-Chien Road, Hu-Hsi Village, Yuan-Shan Hsiang (264), Ilan Hsien, Taiwan ROC<br />
Tel: +886 2 22487599 • Fax: +886 2 22407752<br />
Quality System Cert. No. 506 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm components.<br />
574 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Hosiden Besson Limited<br />
St Joseph's Close Trading Estate, St Joseph's Close, Hove, East Sussex BN3 7EZ, United Kingdom<br />
Tel: +44 (0)1273 860000 • Fax: +44 (0)1273 777501<br />
E-mail: info@hbl.co.uk • Website: www.hbl.co.uk<br />
Quality System Cert. No. 539 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and supply of audible alarm devices.<br />
Huzhou Jiusheng Electric Co Ltd<br />
1000 Xifeng Road, Huzhou Economy & Technology Zone, Huzhou, Zhejiang Province 313000, China<br />
Tel: +86 572 222 8188 • Fax: + 86 572 222 8177<br />
E-mail: tec@hz-tec.com<br />
Quality System Cert. No. 948 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
The manufacture and supply of mineral insulated cables not exceeding 500V.<br />
Iceberg Building Services Limited<br />
1 Station Court, Station Approach, Wickford, Essex SS11 7AT, United Kingdom<br />
Tel: +44 (0)1268 739450 • Fax: +44 (0)1268 739439<br />
E-mail: iceberg@btconnect.com • Website: www.iceberybuildingservices.co.uk<br />
Quality System Cert. No. 934 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning and servicing of fire detection and alarm systems. Design, installation and maintenance of air<br />
conditioning and ventilation systems.<br />
Icopal S. A.<br />
Parc Industriel des Hauts Sarts, Rue de Hermee 186, Herstal, Belgium<br />
Tel: +32 4240 5151 • Fax: +32 4240 5199<br />
E-mail: sales@decra.co.uk • Website: www.decra.co.uk<br />
Quality System Cert. No. 834 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture and supply of metal roof and cladding systems including accessories.<br />
Industrial Door Engineering Limited<br />
Winnington Avenue, Winnington, Northwich, Cheshire CW8 4EQ, United Kingdom<br />
Tel: +44 (0)1606 871832 • Fax: +44 (0)1606 871482<br />
E-mail: sales@industrial-door-eng.co.uk • Website: www.industrial-door-eng.co.uk<br />
Quality System Cert. No. 165 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, installation and servicing of fire rolling shutters and industrial rolling shutters. Installation and servicing of fire doors<br />
and industrial doors.<br />
20 Nov 2011 575
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Influx Measurements Limited<br />
1A Bennett House, The Dean, Alresford, Hampshire SO24 9BQ, United Kingdom<br />
Tel: +44 (0)1962 736736 • Fax: +44 (0)1962 736737<br />
E-mail: townermark@yahoo.co.uk<br />
Quality System Cert. No. 464 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of direct reading flow meters.<br />
IPB N.V.<br />
Steenovenstraat 30, B-8790 Waregem, Belgium<br />
Tel: +32 56 60 79 19 • Fax: +32 56 61 08 85<br />
Quality System Cert. No. 365 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, development, manufacture and sales of plastic sheets.<br />
Irish Driver-Harris Company Limited<br />
Millbanks, New Ross, Co Wexford, Ireland<br />
Tel: +353 51 421 405 • Fax: +353 51 422 983<br />
E-mail: quality@idh.ie<br />
Quality System Cert. No. 408 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of electric cables for use in installations that require safety in the event of fire.<br />
Irish Industrial Tanks Limited<br />
Unit C1, Ballymount Drive Industrial Estate, Ballymount Road, Walkinstown, Dublin 12, Ireland<br />
Tel: +353 1 450 7893 • Fax: +353 1 450 6404<br />
E-mail: irishind@connect.ie • Website: www.iit.ie<br />
Quality System Cert. No. 112 Assessed to ISO 9001:2008<br />
Scope:<br />
Supply and installation of water storage tanks.<br />
Irish Sprinkler & Fire Protection Limited<br />
Damastown Green, Damastown Industrial Estate, Mulhuddart, Dublin 15, Ireland<br />
Tel: +353 1 8614036 • Fax: +353 1 8614037<br />
E-mail: irishsprinkler@joneseng.com • Website: www.joneseng.com<br />
Quality System Cert. No. 382 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
576 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Isoclad Limited<br />
10 Alder Road, West Chirton North Industrial Estate, North Shields, Tyne & Wear NE29 8SD, United Kingdom<br />
Tel: +44 (0)191 258 5052 • Fax: +44 (0)191 259 5742<br />
E-mail: sales@isoclad.co.uk • Website: www.isoclad.co.uk<br />
Quality System Cert. No. 142 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of fire resistant and industrial wall and ceiling cladding materials. Manufacture of fire resistant and industrial cold storage<br />
wall panels. Manufacture of polyisocyanurate foam (PIR) products.<br />
J & J Design Limited<br />
Unit 4, Underbank Way, Carrs Industrial Estate, Haslingden, Rossendale, Lancashire BB4 5HR, United<br />
Kingdom<br />
Tel: +44 (0)1706 223414 • Fax: +44 (0)1706 225639<br />
E-mail: Adrian@jjsprinklers.co.uk • Website: www.jjsprinklers.co.uk<br />
Quality System Cert. No. 299 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
J Durrance & Co Ltd<br />
Durrance House, 855 London Road, West Thurrock, Essex RM20 3LG, United Kingdom<br />
Tel: +44 (0)1708 258999 • Fax: +44 (0)1708 258900<br />
E-mail: sales@jdurrance.co.uk • Website: www.jdurrance.co.uk<br />
Quality System Cert. No. 588 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of pedestrian access security, fire doors and anti bandit screens. Installation and servicing of roller<br />
shutter and fire doors.<br />
Also at:<br />
Unit 3, Hanlon Court, Royal Industrial Estate, Jarrow, Newcastle-upon-Tyne NE32 2HR UK<br />
Tel: +44 (0)191 428 6000 • Fax: +44 (0)191 483 8787<br />
Quality System Cert. No. 588 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture, installation, service and repair of door, grilles, rolling shutters, fire doors and fire roller shutters.<br />
J. Bryceland Fire Systems Ltd<br />
Nobel Road, West Gourdie Industrial Estate, Dundee DD2 4XE, United Kingdom<br />
Tel: +44 (0)1382 624000 • Fax: +44 (0)1382 624300<br />
E-mail: jbryceland@aol.com • Website: www.jbrycelandfiresystems.co.uk<br />
Quality System Cert. No. 960 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of automatic sprinkler systems. Installation of wet and dry hydrant risers and hose reels.<br />
20 Nov 2011 577
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
K.P.F.P. Limited<br />
59 Pound Street, Carshalton, Surrey SM5 3PG, United Kingdom<br />
Tel: +44 (0)20 8544 4844 • Fax: +44 (0)20 8544 4819<br />
E-mail: fire@kpfp.co.uk • Website: kpfp.co.uk<br />
Quality System Cert. No. 725 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, supply, installation, testing and repair of sprinkler systems, hose reels, hydrants and risers.<br />
KAC Alarm Company Limited<br />
KAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United Kingdom<br />
Tel: +44 (0)1527 406655 • Fax: +44 (0)1527 406677<br />
E-mail: sales@kac.co.uk OR marketing@kac.co.uk • Website: www.kac.co.uk<br />
Quality System Cert. No. 166 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of manual call points, sounders and sounder strobes.<br />
Kean Building & Fire Protection Services Limited<br />
39/43 Temple Bar, Willenhall, West Midlands WV13 1SH, United Kingdom<br />
Tel: +44 (0)1902 603550 • Fax: +44 (0)1902 608017<br />
E-mail: kean.fp@btconnect.com<br />
Quality System Cert. No. 411 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and installation of fire sprinkler systems.<br />
Kentallen Fire Protection Limited<br />
Lancaster Road, Lowmoss Industrial Estate, Bishopbriggs, Glasgow G64 2LL, United Kingdom<br />
Tel: +44 (0)141 762 2540 • Fax: +44 (0)141 762 0823<br />
E-mail: kentallen@btconnect.com<br />
Quality System Cert. No. 395 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and installation of fire sprinkler systems.<br />
Kentec Electronics Limited<br />
Units 25-27, Fawkes Avenue, Questor, Dartford, Kent DA1 1JQ, United Kingdom<br />
Tel: +44 (0)1322 222121 • Fax: +44 (0)1322 291794<br />
E-mail: sales@kentec.co.uk • Website: www.kentec.co.uk<br />
Quality System Cert. No. 360 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, sales and servicing of control panels for fire detection, extinguishing release, sprinkler systems, water and smoke<br />
detection, associated power supplies, battery chargers and supply of printed circuit assemblies including metal fabrication, powder<br />
coating and silk screening of enclosures.<br />
578 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Keystone Electric Wire & Cable Company Limited<br />
#110 D.D. 83, Kwan Ti North Village, Fanling, New Territories, Hong Kong<br />
Tel: +852 2691 7183 • Fax: +852 2695 9738<br />
E-mail: sales@keystonecable.com • Website: www.keystonecable.com<br />
Quality System Cert. No. 663 Assessed to ISO 9001:2008<br />
Scope:<br />
Sales:<br />
Design and supply of electric wires and cables for use in installations which require safety in the event of fire.<br />
Dongguan Factory:<br />
Dongguan Keystone Electric Wire & Cable Company Ltd<br />
Ye Sha Management District, Shatin, Dongguan City, Guangdong,<br />
People's Republic of China<br />
Scope:<br />
Design, manufacture and supply of electric wires and cables up to 35KV for use in installations which require safety in the event of fire.<br />
Kidde Products Ltd, trading as AirSense Technology<br />
Unit 1, Caxton Place, Caxton Way, Stevenage, Hertfordshire SG1 2UG, United Kingdom<br />
Tel: +44 (0)1462 751296 • Fax: +44 (0)1462 729137<br />
E-mail: tech@airsense.co.uk • Website: www.airsense.co.uk/airsense<br />
Quality System Cert. No. 404 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of aspirating smoke detectors and supply of aspirating pipe, associated fittings and accessories.<br />
Kingfell Plc<br />
Capital Tower, 12th Floor, 91 Waterloo Road, London SE1 8RT, United Kingdom<br />
Tel: +44 (0)845 60 61 999 • Fax: +44 (0)845 25 81 999<br />
E-mail: enquiries@kingfell.com • Website: www.kingfell.com<br />
Quality System Cert. No. 475 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning and servicing of fire detection and alarm systems.<br />
Kingspan Door Components S.A.<br />
Zone Industrielle De L'Europe 1A, 7900 Leuze-En-Hainaut, Belgium<br />
Tel: +32 (0)69 868222<br />
Website: www.kingspandoor.com<br />
Quality System Cert. No. 1063 Assessed to ISO 9001:2008<br />
Scope:<br />
The design, manufacture and distribution of PUR/PIR foam filled composite door panels and components.<br />
20 Nov 2011 579
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Kingspan Insulation Limited<br />
Pembridge, Leominster, Herefordshire HR6 9LA, United Kingdom<br />
Tel: +44 (0)1544 388601 • Fax: +44 (0)1544 388888<br />
E-mail: info.uk@insulation.kingspan.com • Website: www.insulation.kingspan.com<br />
Also at:<br />
Sherburn Enterprise Park, Enterprise Way, Sherburn-in-Elmet, North Yorkshire LS25 6NA, United Kingdom<br />
Quality System Cert. No. 388 Assessed to ISO 9001:2008<br />
Scope:<br />
Leomister:<br />
Design and manufacture of insulated and fire rated flat and tapered rigid polyurethane, polyisocyanurate and phenolic thermal insulation<br />
boards. Design, manufacture and sales of pre-mitred tapered roof systems.<br />
Scope:<br />
Sherburn-in Elmet:<br />
Manufacture of insulated products.<br />
Kingspan Ltd<br />
Carrickmacross Road, Kingscourt, Co. Cavan, Ireland<br />
Tel: +353 42 969 8572 • Fax: +353 42 969 8576/77<br />
E-mail: info.irl@kingspanpanels.com • Website: www.kingspanpanels.com<br />
Quality System Cert. No. 186 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire resistant wall and roof cladding materials and industrial wall and roof cladding materials, multi-beam<br />
purlins and accessories, gutters, flashing systems and single and double translucent roof lights.<br />
Kingspan Ltd trading as Kingspan Structural, Kingspan Fabrications, Kingspan<br />
Controlled Environments (KCE), Kingspan Profiles and Sections<br />
Sherburn, Malton, North Yorkshire YO17 8PQ, United Kingdom<br />
Tel: +44 (0)1944 710591 • Fax: +44 (0)1944 710777<br />
E-mail: wbc@wards.co.uk • Website: www.wards.co.uk<br />
Quality System Cert. No. 279 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of foam filled fire resistant insulated panels for roof, wall and cold store applications and ancillaries, cold rolled<br />
Multi-Beam, rail and channel <strong>section</strong>s, floor deck profiles; flashings, building ancillaries and architectural façade systems. Design,<br />
manufacture and installation of Kingframe building systems and cold rolled steel <strong>section</strong>s. Pre-treatment and protective coating to steel<br />
and galvanized components for architecturtal and industrial applications.<br />
Kingspan Ltd.<br />
Greenfield Business Park No. 2, Greenfield, Holywell, Flintshire CH8 7HU, United Kingdom<br />
Tel: +44 (0)1352 716100 • Fax: +44 (0)1352 716161<br />
E-mail: info@kingspanpanels.com • Website: www.kingspanpanels.com<br />
Quality System Cert. No. 260 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of fire resistant and industrial wall and roof cladding materials.<br />
580 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
KingspanTarec Industrial Insulation Limited<br />
Glossop Brook Road, Glossop, Derbyshire SK13 8GF, United Kingdom<br />
Tel: +44 (0)870 733 0021 • Fax: +44 (0)870 700 0022<br />
E-mail: info@kingspantarec.co.uk • Website: www.kingspantarec.co.uk<br />
Quality System Cert. No. 035-2 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of polyurethane and phenolic rigid foam insulation.<br />
KME Italy SpA<br />
Via Della Repubblica 257, 55051 Fornaci Di Barga, Lucca, Italy<br />
Tel: +39 0583 701.1 • Fax: +39 0583 701623<br />
E-mail: massimo.banfi@kme.com • Website: www.kme-italy.com<br />
Quality System Cert. No. 427 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of mineral insulated cables for use in installations that require safety in the event of fire.<br />
L.B.S. Group (incorporating L.B.S Security Services Limited - t/a Specialized Door<br />
Services, Russell Shutters, Olsen Shutters and Ranford Doors)<br />
Unit 6, Sterling Trading Estate, Rainham Road South, Dagenham, Essex RM10 8TX, United Kingdom<br />
Tel: +44 (0)208 526 8572 • Fax: +44 (0)208 984 0378<br />
Quality System Cert. No. 247 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture, installation and servicing of industrial doors, industrial rolling shutters and fire rolling shutters.<br />
Liddle Doors Limited<br />
Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom<br />
Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698<br />
E-mail: liddle@liddledoors.co.uk • Website: www.liddledoors.co.uk<br />
Quality System Cert. No. 442 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of specialist steel security doors, screens and glazed steel entrance systems.<br />
Lincs Doors Limited<br />
Innovation Way, Europarc, Grimsby, North East Lincolnshire DN37 9TT, United Kingdom<br />
Tel: +44 (0)1472 311057 • Fax: +44 (0)1472 311058<br />
E-mail: enquiries@lincsdoors.co.uk • Website: www.lincsdoors.co.uk<br />
Quality System Cert. No. 777 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture, supply and installation of industrial and fire doors.<br />
20 Nov 2011 581
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Lingjack Engineering Works PTE Ltd<br />
No. 1 Woodlands Terrace, #03-01 Lingjack Industrial Building 738471, Singapore<br />
Tel: +65 6759 4163 • Fax: +65 6758 7513<br />
E-mail: combat@lingjack.com • Website: www.combat.com.sg<br />
Quality System Cert. No. 501 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of portable fire extinguishers, fire hose reels, breeching inlets, dry risers, high pressure landing valves and fire fighting hose<br />
assemblies. Non-ferrous casting, machining and testing process.*<br />
(*Foundry Address: 35, Jalan Canggih 8, Taman Perindustrian Cemerling, 81800 Ulu Tiram, Johor, Malaysia)<br />
Linkester Fire Protection Limited<br />
4/6 Cross Street, Macclesfield, Cheshire SK11 7PG, United Kingdom<br />
Tel: +44 (0)1625 511272 • Fax: +44 (0)1625 511272<br />
E-mail: sales.linkester@btconnect.com<br />
Quality System Cert. No. 086 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler and foam systems.<br />
Lion Steelworks SDN. BHD.<br />
Lot 4, Solok Waja 3, Kawasan Perindustrian Bukit Raja, 41050 Klang, Selangor, Malaysia<br />
Tel: +603 3341 3822 • Fax: +603 3342 7630<br />
E-mail: lion@fmm.jaring.my<br />
Quality System Cert. No. 639 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Design and manufacture of safes, strong rooms and secure cabinets.<br />
Lixil Nittan Company Limited<br />
1-11-6, Hatagaya, Shibuya-Ku, Tokyo 151-8535, Japan<br />
Tel: +81 3 3468 1116 • Fax: +81 3 3468 1120<br />
Quality System Cert. No. 756 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, development of automatic fire detectors, fire alarm control systems, indicating equipment and fire extinguishing equipment<br />
including management of distribution centres.<br />
Lixil Nittan Electronic Company Limited<br />
1 Higashi-Kibogaoka, Asahi-ku, Yokohama, Kanagawa 241-0826, Japan<br />
Tel: +81 45 364 4751 • Fax: +81 45 363 2678<br />
Quality System Cert. No. 755 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire alarm control equipment.<br />
Also at:<br />
563-6, 1-Chome, Toyonodai, Otonemachi, Kitasaitama-gun, Saitama, Japan<br />
1, Aza Minamihata, Kohnoike, Itami, Hyougo 664-0006, Japan<br />
582 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Scope at above addresses:<br />
Manufacture of automatic fire detectors.<br />
Lowrey Contractors Limited<br />
200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom<br />
Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111<br />
E-mail: lowrey@talk21.com • Website: www.lowrey-contractors.co.uk<br />
Quality System Cert. No. 974 Assessed to ISO 9001:2008<br />
Scope:<br />
Supply and installation of modular security kiosks and cages, perimeter and power fencing, gates, barriers, window barsets and alarm<br />
ducting.<br />
LPG Tecnicas en Extincion de Incendios, S.L.<br />
Mestre Joan Corrales 107-109, 08950 Esplugues de Llobregat, Barcelona, Spain<br />
Tel: +34 93 480 2925 • Fax: +34 93 473 7492<br />
E-mail: marketing@lpg.es • Website: www.lpg.es<br />
Also at:<br />
Sierra de Guadarrama, 32 Naves A y B, Poligono Industrial San Fernando 1, 28830 San Fernando De<br />
Henares, Madrid, Spain<br />
and<br />
C/ Josep Ros i Ros no. 19A y 19B, Poligono Industrial la Clota, 08740 Sant Andreu de la Barca, Barcelona,<br />
Spain<br />
and<br />
Pol. Ind. La Canaleta, Parcela no. 6 Naves 1 y 2, 25300 Tarrega, Lleida, Spain<br />
Quality System Cert. No. 446 Assessed to ISO 9001:2008<br />
Scope:<br />
The design and manufacture of gaseous fire suppression components and the periodical maintenance, inspection, test and refilling of gas<br />
cylinders.<br />
Lubrizol Advanced Materials Europe B.V.B.A<br />
Nijverheidsstraat 30, B-2260 Westerlo, Oevel, Belgium<br />
Tel: +32 14 24 16 11 • Fax: +32 14 24 18 19<br />
Quality System Cert. No. 535 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture, quality control and distribution of Temprite CPVC products.<br />
20 Nov 2011 583
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
M & P Fire Solutions Ltd<br />
Suite 17, The Cubes Offices, Beacon South Quarter, Sandyford, Dublin 18, Ireland<br />
Tel: +353 1 293 3846/47/48/49 • Fax: +353 1 293 7951<br />
E-mail: admin@mpfiresolutions.com<br />
Quality System Cert. No. 795 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
M. J. Quinn Integrated Services Limited<br />
Oak House, Overbrook Lane, Knowsley Business Park, Knowsley, Merseyside L34 9FB, United Kingdom<br />
Tel: +44 (0)151 547 8800 • Fax: +44 (0)151 547 8801<br />
E-mail: enquiries@mjquinn.co.uk • Website: www.mjquinn.co.uk<br />
Quality System Cert. No. 492 Assessed to ISO 9001:2008<br />
Scope:<br />
Installation, commissioning and servicing of fire detection and alarm systems.<br />
M. J. Quinn Integrated Services Limited<br />
5th Floor, 119 Farringdon Road, London EC1R 3DA, United Kingdom<br />
Tel: +44 (0)207 239 8750 • Fax: +44 (0)207 239 8751<br />
E-mail: enquiries@mjquinn.co.uk • Website: www.mjquinn.co.uk<br />
Quality System Cert. No. 529 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning and servicing of fire detection, alarm systems and sprinkler systems.<br />
Mavili Elektronik Ticaret Ve Sanayi A.S.<br />
Bostanci Dudullu Yolu, Kutup Sok, No. 29 Y Dudullu - Umraniye, Istanbul TR 34775, Turkey<br />
Tel: +90 216 4664 505 • Fax: +90 216 4664 510<br />
E-mail: mavili@mavili.com.tr • Website: www.mavigard.com<br />
Quality System Cert. No. 926 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, sale & after sale services of fire & gas detectors, control panels & accessories.<br />
McAvoy Group Limited<br />
2 Ferguson Road, Knockmore Hill Industrial Estate, Lisburn, Co Antrim BT28 2FW, United Kingdom<br />
Tel: +44 (0)870 2408987 • Fax: +44 (0)28 8774 88495<br />
E-mail: sales@mcavoygroup.co.uk • Website: www.mcavoygroup.com<br />
Quality System Cert. No. 728 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and fabrication of portable modular buildings.<br />
584 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
MECE Fire & Security Limited<br />
Courtlodge, Kemsley Street Road, Bredhurst, Gillingham, Kent ME7 3LS, United Kingdom<br />
Tel: +44 (0)1634 260607 • Fax: +44 (0)1634 260278<br />
E-mail: enquiries@mecefireandsecurity.co.uk • Website: www.mecefireandsecurity.co.uk<br />
Quality System Cert. No. 733 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire alarm, security, access control and CCTV systems.<br />
Mercian Shutters Limited<br />
Pearsall Drive, Brades Road Industrial Estate, Oldbury, West Midlands B69 2RA, United Kingdom<br />
Tel: +44 (0)121 544 6124 • Fax: +44 (0)121 552 6793<br />
E-mail: info@merciandoors.co.uk • Website: www.merciandoors.co.uk<br />
Quality System Cert. No. 355 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, installation, servicing and repair of industrial doors, industrial rolling shutters, fire doors and fire rolling shutters.<br />
Mercian Industrial Doors (Southern) Limited<br />
t/a Mercian Industrial Doors Southern, 10-12 Galleymead Road, Colnbrook, Slough, Berkshire SL3 0EN UK<br />
Tel: +44 (0)1753 681 020 • Fax: +44 (0)1753 684 842<br />
Scope:<br />
Installation, servicing and repair of industrial doors, industrial rolling shutters, fire doors, fire rolling shutters and collapsible gates.<br />
Manufacture of collapsible gates.<br />
Mercury Engineering<br />
Mercury House, Sandyford Industrial Estate, Foxrock, Dublin 18, Ireland<br />
Tel: +353 1 216 3000 • Fax: +353 1 216 3006<br />
E-mail: fireprotection@mercury.ie • Website: www.mercury.ie<br />
Quality System Cert. No. 231 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Midas Technologies (GB) Limited<br />
Unit A, Roundhouse Close, Eastern Industry, Peterborough PE1 5TA, United Kingdom<br />
Tel: +44 (0)1733 342600 • Fax: +44 (0)1733 346672<br />
E-mail: sales@midastech.co.uk • Website: www.midastech.co.uk<br />
Quality System Cert. No. 421 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of access covers and general metal fabrication.<br />
Midland Door Services Limited<br />
Booth Street, Smethwick, West Midlands B66 2PF, United Kingdom<br />
Tel: +44 (0)121 565 0022 • Fax: +44 (0)121 565 0055<br />
E-mail: ralph@mdsind.co.uk • Website: www.mdsind.co.uk<br />
Quality System Cert. No. 964 Assessed to ISO 9001:2008<br />
Scope:<br />
20 Nov 2011 585
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Manufacture, installation, service and repair of all types of door systems.<br />
MITIE McCartney Fire Protection Limited<br />
Meiklewood Gate, 35 Meiklewood Road, Glasgow G51 4GB, United Kingdom<br />
Tel: +44 (0)141 880 2700 • Fax: +44 (0)141 880 2701<br />
E-mail: fireprotection@mitie.co.uk • Website: www.mitie.co.uk<br />
Also included within the scope of certification<br />
Unit 11, Hobbs Cross Business Centre, Hobbs Cross Road, Theydon Garnon, Essex CM16 7NY, United<br />
Kingdom<br />
Tel: +44 (0)1992 813 598 • Fax: +44 (0)1992 814 541<br />
and<br />
Units 16 & 18, Whitwick Business Centre, Stenson Road, Coalville, Leicestershire LE67 4JP, United Kingdom<br />
Tel: +44(0)1530 276 166 • Fax: +44(0)1530 276 167<br />
Quality System Cert. No. 769 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, specification, installation, inspection, servicing and repair of all types of passive fire protection and performance coating systems.<br />
MITIE Technical Facilities Management Limited (MITIE Fire and Security Systems)<br />
Ventura House, Ventura Park Road, Tamworth B78 3HL, United Kingdom<br />
Tel: +44 (0)1827 303251 • Fax: +44 (0)1827 309798<br />
Website: www.mitie.com<br />
Quality System Cert. No. 776 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning and servicing of fire detection and alarm systems.<br />
Mitsubishi Plastics Inc<br />
Hiratsuka Factory, 2-1-35 Nishishindo, Hiratsuka City, Kanagawa Prefecture 254-8614, Japan<br />
Tel: +81 4 6322 8065 • Fax: +81 4 6355 9450<br />
E-mail: mpi1377@cc.mpi.co.jp • Website: www.mpi.co.jp<br />
Sales Enquiries:<br />
1-2-2, Nihonbashi Hongokucho, Chuo-ku, Tokyo 103-0021, Japan<br />
Tel: +81 3 3279 3455 • Fax: +81 3 3279 6740<br />
E-mail: asano.hiroki@mf.mpi.co.jp • Website: www.mpi.co.jp<br />
Quality System Cert. No. 447 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of hot press moulded GRP <strong>section</strong>al water storage tanks.<br />
586 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Modgal Metal (99) Limited<br />
Rosh Pina Industrial Park, Rosh Pina 12000, Israel<br />
Tel: +972 4 691 4222 • Fax: +972 4 691 4202<br />
E-mail: modgalmetal@modgal-metal.com • Website: www.modgalmetal.com<br />
Quality System Cert. No. 123 Assessed to ISO 9001<br />
Scope:<br />
Manufacture of pipe couplings, fittings and general purpose malleable, ductile and grey iron castings.<br />
Monarflex<br />
Lyskaer 10,, DK-2730 Herlev, Copenhagen, Denmark<br />
Tel: +45 44 88 55 50 • Fax: +45 44 88 55 99<br />
E-mail: contact@monarflex.com • Website: www.special-fire.com<br />
Quality System Cert. No. 540 Assessed to ISO 9001<br />
Scope:<br />
Manufacture and supply of reinforced plastic sheeting and special membranes, including related products.<br />
Morgan Marine Limited<br />
Llandybie, Ammanford, Carmarthenshire SA18 3GY, United Kingdom<br />
Tel: +44 (0)1269 850437 • Fax: +44 (0)1269 850656<br />
E-mail: sales@morgan-marine.com • Website: www.morgan-marine.com<br />
Quality System Cert. No. 1051 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of industrial housing, covers and tanks including RF and NEMP screened enclosures and sound<br />
proof housings in composite materials including plastic, alloys and timber.<br />
Morley-IAS Fire Systems By Honeywell<br />
Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom<br />
Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888<br />
E-mail: sales@morleyias.co.uk • Website: www.morley-ias.co.uk<br />
Quality System Cert. No. 429 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm systems.<br />
20 Nov 2011 587
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
N.V. Joris IDE<br />
Hille 174, B-8750, Zwevezele, Belgium<br />
Tel: +44 (0)1928 571 444 • Fax: +44 (0)1928 571 488<br />
E-mail: division.export@joriside.co.uk • Website: www.joriside.co.uk<br />
and factories at:<br />
Kortrijksestraat 505, B-8020 Oostkamp, Belgium<br />
and<br />
Bosveldstraat 4, B-8750 Zwevezele, Belgium<br />
Quality System Cert. No. 700 Assessed to ISO 9001:2008<br />
Scope:<br />
Sales, design, fabrication & supply of steel construction materials (roof & wall panels, roof tiles, technical profiles, galvanized profiles &<br />
insulating sandwich panels).<br />
Nanjing Fire Protection Technology Co Limited<br />
12 Shiyang Road, Baixia District, Nanjing, China<br />
Tel: 86 25 842 79156 • Fax: 86 25 842 79101<br />
E-mail: yaoQl@tuna.com.cn<br />
Quality System Cert. No. 874 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of fire sprinklers.<br />
National Fire Fighting Manufacturing Company Limited (NAFFCO)<br />
PO Box 17014, Jebel Ali, Dubai, United Arab Emirates<br />
Tel: +9714 881 5653 • Fax: +9714 881 6229<br />
E-mail: natfire@emirates.net.ae • Website: www.naffco.com<br />
Quality System Cert. No. 463 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, installation and servicing of portable fire extinguishers, mobile fire extinguishers, auto extinguishing systems, fire<br />
hoses, hose reels and fire cabinets. Design and assembly of fire pumps, fire pump sets and fire hydrants. Design, manufacture,<br />
installation and servicing of water supply systems, fire sprinklers, water spray, foam systems and gaseous fixed fire fighting systems.<br />
Supply of fire blankets. Manufacture of dry riser inlet boxes to BS 5041-5.<br />
National Sprinkler Company Limited<br />
Unit 4B, Fingal Bay Business Park, Balbriggan, Co Dublin, Ireland<br />
Tel: +353 1 690 4001/4040 • Fax: +353 1 841 7400<br />
E-mail: info@nationalsprinkler.ie • Website: www.nationalsprinkler.ie<br />
Quality System Cert. No. 772 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
588 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Nexans Turkiye Endustri ve Ticaret A.S.<br />
Izmir Karayolu Uzeri 6.km, Denizli, Turkey<br />
Tel: 0090 212 266 0160 • Fax: 0090 212 266 0170<br />
E-mail: Info.turkey@nexans.com • Website: www.nexans.com.tr<br />
Quality System Cert. No. 946 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
The manufacture and supply of electric cables and wires, including cables that are used in installations which require safety in the event<br />
of fire.<br />
NIBCO Inc<br />
105 Quality Court, Charlestown, IN 471111-1149, United States<br />
Tel: +1 812 256 8530 • Fax: +1 812 256 8585<br />
Also at:<br />
701, Eisenhower Drive North, Goshen, Indiana 46526, United States<br />
Tel: +1 574 296 1240 • Fax: +1 574 296 1241<br />
Quality System Cert. No. 878 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of CPVC fittings for fire sprinkler systems.<br />
Nields Plastic Company Limited<br />
Units 1 -2, Foley Works Estate, Hereford HR1 2SF, United Kingdom<br />
Tel: +44 (0)1432 268341 • Fax: +44 (0)1432 353247<br />
E-mail: sales@nields.co.uk<br />
Quality System Cert. No. 342 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of low density polythene film including coloured, printed, anti-static, conductive and flame retardant to customer<br />
specification: film thickness from 12.5 to 375 microns and widths from 50mm (2 inches) to 1524mm (60 inches). Material supplied on reels<br />
in the form of lay flat tube, centre folded sheet, double wound sheet, single wound sheet, pre-formed lay flat tube, or converted into bags.<br />
Nitin Fire Protection Industries Limited<br />
A-117, T.T.C. Industrial Area, Pawane, Navi Mumbai - 400 701, Maharashtra, India<br />
Tel: +91 22 7633796<br />
E-mail: nitinfire@vsni.com<br />
Also at:<br />
29, Vadhani Estate, L.B.S. Marge, Ghatkoper (West), Mumbai - 400 086, Maharashtra, India<br />
And<br />
D-20/4, T.T.C. Industrial Estate, Turbhe, Navi Mumbai - 400 701, Maharashtra, India<br />
Quality System Cert. No. 855 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Procurement and supply of gaseous fire fighting components. Procurement, filling, supply and assembly of gaseous fixed fire fighting<br />
systems.<br />
20 Nov 2011 589
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Nittan (UK) Limited<br />
Hipley Street, Old Woking, Surrey GU22 9LQ, United Kingdom<br />
Tel: +44 (0)1483 769555/8 • Fax: +44 (0)1483 756686<br />
E-mail: sales@nittan.co.uk • Website: www.nittan.co.uk<br />
Quality System Cert. No. 041 Assessed to ISO 9001:2008<br />
Scope:<br />
The manufacture of fire detection, alarm and monitoring equipment.<br />
Nittan Fire Protection System (Zhongshan) Company, Limited<br />
The 2nd Floor, No. 29 Factory Building, New Concentrated Constructed Quarter, Zhongshan Torch Hi-Tech<br />
Industrial Dvlpmnt Zone, Zhongshan, Guangdong 528437, China<br />
Tel: +86 760 828 5700 • Fax: +86 760 828 1000<br />
Quality System Cert. No. 842 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of smoke detectors and their ancillaries.<br />
NMC (UK) Limited<br />
Tafarnaubach Industrial Estate, Tredegar, South Wales NP22 3AA, United Kingdom<br />
Tel: +44 (0)800 834 704 • Fax: +44 (0)800 834 705<br />
E-mail: enquiries@protection.co.uk • Website: www.protection.co.uk<br />
Quality System Cert. No. 634 Assessed to ISO 9001:2008<br />
Scope:<br />
The manufacture and supply of cellular polymers in extruded tube and profiles form including the supply of foam and polyurethane<br />
decorative products. The manufacture of fire retardent tubing and profiles.<br />
No Climb Products Limited<br />
Edison House, 163 Dixons Hill Road, Welham Green, Hertfordshire AL9 7JE, United Kingdom<br />
Tel: +44 (0)1707 282760 • Fax: +44 (0)1707 282777<br />
E-mail: info@noclimb.com • Website: www.noclimb.com<br />
Quality System Cert. No. 813 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection test equipment.<br />
Nobel Fire Systems<br />
Unit 6 Southgate Industrial Estate, Green Lane, Heywood, Lancashire OL10 1ND, United Kingdom<br />
Tel: +44 (0)1706 625 777 • Fax: +44 (0)1706 625 325<br />
E-mail: info@nobel-fire-systems.com • Website: www.nobel-fire-systems.com<br />
Quality System Cert. No. 642 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, supply, installation, commissioning & servicing of gas generator, foam, dry chemical, gaseous, watermist & <strong>part</strong>iculate aerosol fire<br />
suppression systems.<br />
590 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Northern Ireland Plastics Limited<br />
39 Shrigley Road, Killyleagh, Co. Down, Northern Ireland BT30 9SR, United Kingdom<br />
Tel: +44 (0)2844 828753/4 • Fax: +44 (0)2844 828809<br />
E-mail: info@niplastics.co.uk<br />
Quality System Cert. No. 341 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of twin wall polypropylene sheet.<br />
Notifier Fire Systems by Honeywell<br />
Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom<br />
Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888<br />
E-mail: sales@notifiersystems.co.uk • Website: www.notifierfiresystems.co.uk<br />
Quality System Cert. No. 154 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm systems and components.<br />
Nu-Form Fire UK Limited<br />
390 Manchester Road, Gollinrod, Bury, Lancashire BL9 5NB, United Kingdom<br />
Tel: +44 (0)1706 825111 • Fax: +44 (0)1706 827111<br />
E-mail: info@sprinklersystems.co.uk • Website: www.sprinklersystems.co.uk<br />
Quality System Cert. No. 214 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Olympic Fire Protection Limited<br />
Fire House, Mayflower Close, Chandlers Ford, Eastleigh, Hampshire SO53 4AR, United Kingdom<br />
Tel: +44 (0)870 608 4350 • Fax: +44 (0)870 608 4351<br />
E-mail: info@olympicfire.co.uk • Website: www.olympicfire.co.uk<br />
Quality System Cert. No. 173 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems, hosereels, dry risers and hydrants.<br />
Pace Technology Co. Limited<br />
The Sanlian Industrial Estate of Gulao Town, Heshan City, Guangdong Province, China<br />
Tel: +852 917 66779 • Fax: +852 237 45126<br />
E-mail: peter_pace36@hotmail.com<br />
Quality System Cert. No. 656 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of blanket control and heating under-blanket and manufacture of carbon monoxide detectors.<br />
20 Nov 2011 591
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Panel Projects Limited<br />
Portview Road, Avonmouth, Bristol BS11 9LQ, United Kingdom<br />
Tel: +44 (0)117 316 7000 • Fax: +44 (0)117 316 7001<br />
Quality System Cert. No. 881 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and supply of composite insulation and fire retardant panels.<br />
Paroc Panel System Oy Ab<br />
FIN-21600, Parainen, Finland<br />
Tel: +358 46 876 8000 • Fax: +358 46 876 8702<br />
E-mail: panelinfo@paroc.com • Website: www.paroc.com<br />
Quality System Cert. No. 381 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of fire resistant composite panels.<br />
Patterson Pump Ireland Limited<br />
Unit 14, Mullingar Business Park, Mullingar, Co Westmeath, Ireland<br />
Tel: +353 44 47078 • Fax: +353 44 47896<br />
E-mail: rpelot@ie.pattersonpumps.com • Website: www.ie.pattersonpumps.com<br />
Quality System Cert. No. 436 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire pump sets. Manufacture of fire pumps.<br />
PEL Services Limited<br />
Belvue Business Centre, Belvue Road, Northolt, Middlesex UB5 5QQ, United Kingdom<br />
Tel: +44 (0)20 8839 2100 • Fax: +44 (0)20 8841 1948<br />
E-mail: pel@pel.co.uk • Website: www.pel.co.uk<br />
Quality System Cert. No. 981 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, supply, installation and commissioning of public address, fire alarm, security and communications equipment.<br />
Pendle Designs Limited<br />
Pendle House, Webb Street, Bury, Lancs BL8 1AF, United Kingdom<br />
Tel: +44 (0)161 764 2252 • Fax: +44 (0)161 763 1429<br />
E-mail: sprinklers@pendledesigns.co.uk<br />
Quality System Cert. No. 138 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems. Manufacture of fabricated pipework for fire sprinkler systems.<br />
592 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Peripheral Support Services Limited<br />
Unit 14, Enterprise Court, Rankine Road, Basingstoke, Hampshire RG24 8GE, United Kingdom<br />
Tel: +44 (0)1256 844 685 • Fax: +44 (0)1256 810 082<br />
E-mail: sales@pss-firequest.co.uk • Website: www.pss-firequest.co.uk<br />
Quality System Cert. No. 888 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, test and repair of fire control systems, emergency lighting control systems and LST radiator covers and<br />
accessories.<br />
Pittway Tecnologica Srl.<br />
Via Caboto 19/3, 34147 Trieste, Italy<br />
Tel: +39 040 94 90111 • Fax: +39 040 38 2137<br />
E-mail: sandro_bonin@systemsensor.com • Website: www.systemsensoreurope.com<br />
European Sales:<br />
System Sensor Europe, Life Safety Distribution AG, Wilstrasse 11 (Building U31), CH-8610 Uster, Switzerland<br />
Tel: +41 44 943 4424 • Fax: +41 44 943 4399<br />
E-mail: sse.marketing@systemsensor.com • Website: www.systemsensoreurope.com<br />
Quality System Cert. No. 199 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, development and manufacture of control and signalling devices for fire prevention systems and gas detectors.<br />
Potter Electric Signal Company<br />
1609 Park 370 Place, Hazelwood, St Louis, Missouri 63042, United States<br />
Tel: +1 314 595 6900 • Fax: +1 314 595 6999<br />
E-mail: info@pottersignal.com • Website: www.pottersignal.com<br />
Quality System Cert. No. 125 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of electric alarm pressure switches and water flow alarm switches.<br />
Powershield Doors Limited<br />
21 Ferguson Drive, Knockmore Hill Industrial Park, Lisburn, Northern Ireland BT28 2EX, United Kingdom<br />
Tel: +44 (0)28 9266 2200 • Fax: +44 (0)28 9260 3600<br />
E-mail: sales@powershield.co.uk • Website: www.powershield.co.uk<br />
Quality System Cert. No. 852 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of industrial doors, fire doors and windows.<br />
Pressex UK Limited<br />
Kingsway South, Team Valley, Gateshead, Tyne & Wear NE11 0SH, United Kingdom<br />
Tel: +44 (0)191 497 3430 • Fax: +44 (0)191 497 3431<br />
E-mail: pressex@responsive-engineering.com • Website: www.responsive-engineering.com<br />
Quality System Cert. No. 870 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
20 Nov 2011 593
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Manufacture and supply of anti duress mechanical and electromechanical devices for ATM security.<br />
Professional Barrier Systems Limited<br />
16 Stapledon Road, Orton Southgate, Peterborough PE2 6TD, United Kingdom<br />
Tel: +44 (0)1733 361511 • Fax: +44 (0)1733 361512<br />
E-mail: mail@extendor.co.uk • Website: www.extendor.co.uk<br />
Quality System Cert. No. 869 Assessed to ISO 9001:2008<br />
Scope:<br />
The design, manufacture and installation of barrier systems.<br />
Project Fire Products Limited (incorporating Project Fire Engineers)<br />
Pasturefields Lane Industrial Estate, Pasturefields Lane, Hixon, Staffordshire ST18 0PH, United Kingdom<br />
Tel: +44 (0)1889 270999 • Fax: +44 (0)1889 270974<br />
E-mail: sales@projectfire.co.uk • Website: www.projectfire.co.uk<br />
Quality System Cert. No. 060 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler and water spray systems. Assembly, installation and commissioning, repair and<br />
servicing of water flow switch and alarm valve testing devices.<br />
Protec Camerfield Limited<br />
5 Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom<br />
Tel: +44 (0)1282 717474 • Fax: +44 (0)1282 717475<br />
E-mail: camerfield@protec.co.uk • Website: www.protec.co.uk<br />
Quality System Cert. No. 268 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, service and maintenance of fire sprinkler systems and gaseous extinguishing systems.<br />
Protec Fire Detection plc<br />
Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom<br />
Tel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273<br />
E-mail: sales@protec.co.uk • Website: www.protec.co.uk<br />
Quality System Cert. No. 201 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, installation, commissioning and servicing of fire detection and alarm systems and components.<br />
The following locations are included within the scope of certification:<br />
Swanley<br />
Unit 4<br />
White Oak Square<br />
London Road<br />
Swanley<br />
Kent BR8 7AG<br />
Fareham<br />
Unit 10<br />
Fulcrum 4<br />
Solent Way<br />
Fareham<br />
Hampshire PO15 7FT<br />
594 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Leeds<br />
Unit 1, Ashfield Court<br />
Whitehall Road<br />
Leeds LS12 5JB<br />
Tel: 0845 456 5388<br />
Cannock<br />
5 Morston Court<br />
Blakeney Way<br />
Kingswood Lakeside<br />
Cannock<br />
Staffordshire WS11 8JB<br />
Protec International Limited<br />
Construction House, Adlington Industrial Estate, Adlington, Cheshire SK10 4NL, United Kingdom<br />
Tel: +44 (0)1625 855666 • Fax: +44 (0)1625 855601<br />
E-mail: enquiries@protection.co.uk • Website: www.protection.co.uk<br />
Quality System Cert. No. 843 Assessed to ISO 9001:2008<br />
Scope:<br />
The procurement and supply of specialist temporary protection materials and scaffold cladding materials. Flame retardant products for<br />
building and construction industry.<br />
Provincial Sprinkler Co. Limited<br />
Unit 4, Cork Airport Industrial Estate, Kinsale Road, Cork, Ireland<br />
Tel: +353 (0)21 4965058 • Fax: +353 (0)21 4317425<br />
E-mail: info@provincial-sprinkler.ie • Website: www.provincial-sprinkler.ie<br />
Quality System Cert. No. 440 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Prysmian Cables & Systems Limited<br />
Energy Cables Unit, Wrexham Industrial Estate, Wrexham LL13 9PH, United Kingdom<br />
Tel: +44 (0)1978 662345 • Fax: +44 (0)1978 662292<br />
E-mail: cables.marketing.uk@prysmian.com • Website: www.prysmian.co.uk<br />
Quality System Cert. No. 517 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of electrical cable for installations that require safety in the event of a fire.<br />
Prysmian Cables & Systems Ltd<br />
Energy Cables, Chickenhall Lane, Bishopstoke, Eastleigh, Hants SO50 6YU, United Kingdom<br />
Tel: +44 (0)8457 678345 • Fax: +44 (0)2380 295465<br />
E-mail: cables.marketing.uk@prysmian.com • Website: www.prysmian.co.uk<br />
Overseas:<br />
Tel: +44 (0)2380 295555<br />
Quality System Cert. No. 077 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of electric cable for use in installations that require safety in the event of fire.<br />
20 Nov 2011 595
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Prysmian Power Cables & Systems Australia Pty Limited<br />
1 Heathcote Road, Liverpool, Sydney, New South Wales 2170, Australia<br />
Tel: +61 2 9600 0777 • Fax: +61 2 9600 0303<br />
Website: www.pirelli.com<br />
Quality System Cert. No. 422 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of cables for use in installations that require safety in the event of fire.<br />
PSF Wales Limited<br />
Llys Rhiannon, Cil Yr Ychen Industrial Estate, Landeilo Road, Llandybie, Ammanford, Carmarthenshire SA18<br />
3GY, United Kingdom<br />
Tel: +44 (0)1269 851777 • Fax: +44 (0)1269 851747<br />
E-mail: sales@psfwales.co.uk • Website: www.psfwales.co.uk<br />
Quality System Cert. No. 953 Assessed to ISO 9001:2008<br />
Scope:<br />
The design and manufacture of sheet metalwork, fabrications and security doors.<br />
Qinhuangdao Taidy Flex-Tech Co. Ltd<br />
No. 5 Yongdinghe Road, Qinhuangdao Economic & Technology Development Zone, Hebei 066004, China<br />
Tel: +86 335 8586186 • Fax: +86 335 8586190<br />
E-mail: taidy@taidy.com • Website: www.taidy.com<br />
Quality System Cert. No. 764 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of "FlexHead" flexible hoses for fire sprinkler systems.<br />
Quinn Therm Limited<br />
Scotchtown, Ballyconnell, Co. Cavan, Ireland<br />
Tel: +353 49 952 5604 • Fax: +353 49 952 5601<br />
E-mail: info@quinn-therm.com • Website: www.quinn-therm.com<br />
Quality System Cert. No. 893 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of flat roof systems.<br />
R & S Fire & Security Services Limited<br />
Trafalgar House, 712 London Road, Grays, West Thurrock, Essex RM20 3JT, United Kingdom<br />
Tel: +44 (0)1708 683040 • Fax: +44 (0)1708 683068<br />
E-mail: sales@rs-fire.com • Website: www.rs-fire.com<br />
Quality System Cert. No. 1057 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning and servicing of fire detection and alarm gas extinguishing systems.<br />
596 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
RAMCRO S.p.A<br />
Via Marzorati, 15 - 20014 Nerviano, Milan, Italy<br />
Tel: +39 0331 406560 • Fax: +39 0331 406559<br />
E-mail: ramcro@ramcro.it<br />
Quality System Cert. No. 568 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of electric cables including cables used for installations that require safety in the event of fire and the<br />
supply of fibre optic cables.<br />
Rapidrop Global Limited<br />
Rutland Business Park, Newark Road, Peterborough PE1 5WA, United Kingdom<br />
Tel: +44 (0)1733 847 510 • Fax: +44 (0)1733 553 958<br />
E-mail: rapidrop@rapidrop.com • Website: www.rapidrop.com<br />
Quality System Cert. No. 566 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and testing of fire protection equipment including fire sprinklers, valves and fire sprinkler systems components sub<br />
assemblies. Procurement, stockholding and supply of fire system products and manual fire extinguishing equipment.<br />
Red Rose Fire Protection Limited<br />
Unit 2, Atlas Foundry Estate, Brieryfield Road, Preston PR1 8SR, United Kingdom<br />
Tel: +44 (0)1772 822133 • Fax: +44 (0)1772 822144<br />
E-mail: redrosefp@aol.com<br />
Quality System Cert. No. 384 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and installation of fire sprinkler systems.<br />
Reliable Fire Sprinkler Limited<br />
Unit 25, Birches Industrial Estate, East Grinstead RH19 1XZ, United Kingdom<br />
Tel: +44 (0)1342 316800 • Fax: +44 (0)1342 314679<br />
E-mail: gleonard@reliablesprinkler.com • Website: www.reliablesprinkler.com<br />
Quality System Cert. No. 140 Assessed to ISO 9001:2008<br />
Scope:<br />
Stockholding and supply of fire sprinklers, fire protection valves and related products for fire sprinkler and water spray systems.<br />
20 Nov 2011 597
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Retainagroup Limited<br />
Unit 5, St John's Court, Foster Road, Ashford Business Park, Ashford, Kent TN24 0SJ, United Kingdom<br />
Tel: +44 (0)1233 506400 • Fax: +44 (0)1233 506401<br />
E-mail: cust.service@retainagroup.co.uk • Website: www.retainagroup.com<br />
Also included within the scope of certification<br />
Unit 2, Highpoint Business Village, Henwood, Ashford, Kent TN24 8DH<br />
5 Windward House, Plantation Wharf, London SW11 3TU, United Kingdom<br />
Tel: +44 (0)20 7801 4800 • Fax: +44 (0)20 7801 4801<br />
24 hour Telephone Number: 07000 111333<br />
Quality System Cert. No. 493 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of security marking devices and registration of items of property.<br />
RGB Integrated Services Limited<br />
223-236 Claremont House, Nestle Avenue, Hayes, Middlesex UB3 4SH, United Kingdom<br />
Tel: +44 (0)208 573 9882 • Fax: +44 (0)208 711 3916<br />
E-mail: info@rgb-services.com • Website: www.rgb-services.com<br />
Quality System Cert. No. 1074 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, testing, inspection and commissioning of electrical installations and design, installation, commissioning and servicing<br />
of fire detection and alarm systems.<br />
RGT Fire Protection Limited<br />
95 Beaumont Road, Bournville, Birmingham B30 2EB, United Kingdom<br />
Tel: +44 (0)121 433 5175 • Fax: +44 (0)121 486 1847<br />
E-mail: info@rgtfire.com<br />
Quality System Cert. No. 745 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and commissioning of fire sprinkler systems.<br />
Richmond Fire Engineers Limited<br />
30 Firby Road, Gallowfields Trading Estate, Richmond, North Yorkshire DL10 4ST, United Kingdom<br />
Tel: +44 (0)1748 825612 • Fax: +44 (0)1748 825935<br />
E-mail: Sprinklers@richmondfire.co.uk • Website: www.richmondfire.co.uk<br />
Quality System Cert. No. 297 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and service of fire sprinkler systems.<br />
598 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
RMD Fire Control Limited<br />
The Coach House, 22 Lower Stone Street, Maidstone, Kent ME15 6LX, United Kingdom<br />
Tel: +44 (0)1622 682522 • Fax: +44 (0)1622 692675<br />
E-mail: sprinklers@rmdfire.co.uk • Website: www.rmdfire.co.uk<br />
Quality System Cert. No. 102 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems, hose reels and dry risers.<br />
Robust UK Limited<br />
Brookhouse Way, Brookhouse Industrial Estate, Cheadle, Stoke-on-Trent, Staffordshire ST10 1SR, United<br />
Kingdom<br />
Tel: +44 (0)1538 752600 • Fax: +44 (0)1538 752604<br />
E-mail: sales@robust-uk.com • Website: www.robust-uk.com<br />
Factory:<br />
Unit 9B, Blythe Park, Sandon Road, Creswell, Stoke-on-Trent, Staffordshire ST11 9RD, United Kingdom<br />
Quality System Cert. No. 1070 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and supply of doorsets for customers and or published requirements.<br />
Rockwool Limited<br />
Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom<br />
Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302<br />
E-mail: info@rockwool.co.uk • Website: www.rockwool.co.uk<br />
Quality System Cert. No. 022 Assessed to ISO 9001:2008<br />
Scope:<br />
The design and manufacture of stone wool products and systems.<br />
Rolland Sprinklers<br />
Usine de 73410, Mognard, France<br />
Tel: +33 479 547 250 • Fax: +33 479 547 248<br />
E-mail: info@rolland-sprinklers.com<br />
Quality System Cert. No. 295 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of fire sprinklers.<br />
Ross Fire Protection Limited<br />
29 Deerdykes View, Westfield, Cumbernauld G68 9HN, United Kingdom<br />
Tel: +44 (0)1236 738502 • Fax: +44 (0)1236 727977<br />
E-mail: info@rossfire.co.uk • Website: www.rossfire.co.uk<br />
Quality System Cert. No. 124 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and service of fire sprinkler and water spray systems.<br />
20 Nov 2011 599
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Rotary Firematic Limited<br />
5 Trench Road, Mallusk Industrial Estate, Newtownabbey, Co Antrim, Northern Ireland BT36 8XA, United<br />
Kingdom<br />
Tel: +44 (0)2890 831200 • Fax: +44 (0)2890 831201<br />
E-mail: mechanical.contracts@rotarygroup.com<br />
Quality System Cert. No. 107 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and installation of fire sprinkler systems. Fabrication of pipework for fire sprinkler systems.<br />
Rotherham CNC Ltd<br />
Unit 30 Orgreave Close, Dore House Industrial Estate, Handsworth, Sheffield S13 9NP, United Kingdom<br />
Tel: +44 (0)114 269 9800 • Fax: +44 (0)114 269 7949<br />
E-mail: sales@rotherhamcnc.f9.co.uk<br />
Quality System Cert. No. 778 Assessed to ISO 9001:2008<br />
Scope:<br />
Provision of engineered precision components.<br />
RSM Refko Installations Limited<br />
Unit 8, Capstan Centre, Thurrock Park Way, Tilbury, Essex RM18 7HH, United Kingdom<br />
Tel: +44 (0)1375 855500 • Fax: +44 (0)1375 855533<br />
E-mail: rsmrefko@btconnect.com<br />
Quality System Cert. No. 336 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems. Installation of gaseous fire extinguishing systems.<br />
Ruukki Polska Sp. Z.o.o.<br />
Lukowska 7/9 Street, Oborniki, Wielkopolskie, 64-600, Poland<br />
Tel: +48 61 296 8510 • Fax: +48 61 296 8545<br />
Website: www.ruukki.com<br />
Quality System Cert. No. 1052 Assessed to ISO 9001:2008<br />
Scope:<br />
Sandwich panels with PIR core for external claddings, roof coverings and <strong>part</strong>ition walls.<br />
S.F.S. FIRE SERVICES LIMITED (trading as Hall & Kay Fire Engineering and Chubb<br />
Fire Mechanical Division)<br />
1st Floor, Sefton Lodge, Clewer Hill Road, Windsor SL4 4FT, United Kingdom<br />
Tel: +44 (0)1753 833444 • Fax: +44 (0)1753 833434<br />
E-mail: windsor@hkfire.co.uk • Website: www.hkfire.co.uk<br />
Quality System Cert. No. 223 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems, hydrants, hose reels and dry/wet risers together with the supply and servicing<br />
of fire extinguishers. Supply of fire fighting products.<br />
600 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
S.F.S. Fire Services Ltd, T/A Hall & Kay Fire Engineering<br />
3 Peerglow Centre, Marsh Lane, Ware, Hertfordshire SG12 9QL, United Kingdom<br />
Tel: +44 (0)1920 460616 • Fax: +44 (0)1920 461113<br />
E-mail: cpfware@hkfire.co.uk • Website: www.hkfire.co.uk<br />
Quality System Cert. No. 1055 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and installation of fire sprinkler systems.<br />
Safe Partnership<br />
3 East Street, Wareham, Dorset BH20 4NN, United Kingdom<br />
Tel: +44 (0)1929 551100 • Fax: +44 (0)1929 553300<br />
E-mail: safe@safe<strong>part</strong>nership.org • Website: www.safe<strong>part</strong>nership.co.uk<br />
Quality System Cert. No. 835 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture, supply, installation, maintenance and repair of timber door sets.<br />
Supply, installation, maintenance and repair of domestic physical security products.<br />
SafeGuard Doors, A Division of Adams Rite Europe Limited<br />
School Street, Willenhall, West Midlands WV13 3PW, United Kingdom<br />
Tel: +44 (0))1902 364601 • Fax: +44 (0)1902 364602<br />
E-mail: sales@safeguarddoors.co.uk • Website: www.safeguarddoors.co.uk<br />
Quality System Cert. No. 661 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of security, bullet resistant, blast effect and fire doors.<br />
Safeguard Security, a trade name of WBH Industries<br />
Unit 5, 229 Torrington Avenue, Coventry CV4 9HN, United Kingdom<br />
Tel: +44 (0)2476 470 600 • Fax: +44 (0)2476 471 600<br />
E-mail: info@safeguardsecurity.co.uk • Website: www.safeguardsecurity.co.uk<br />
Quality System Cert. No. 418 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and installation of sliding security grilles.<br />
Safety Hi-Tech Srl<br />
Via Cavour, 96 - 67051 Avezzano (AQ), Italy<br />
Tel: +39 0863 1940720 • Fax: +39 0863 1940724<br />
E-mail: mail@safetyhitech.com • Website: www.safetyhitech.com<br />
Quality System Cert. No. 969 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Production of components and halocarbon gases for fire suppression systems.<br />
20 Nov 2011 601
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Safety Technology International (Europe) Limited<br />
Unit 49G Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire B98 0HU, United Kingdom<br />
Tel: +44 (0)1527 520999 • Fax: +44 (0)1527 501999<br />
E-mail: sales@sti-europe.com • Website: www.sti-europe.com<br />
Quality System Cert. No. 653 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire indicating equipment including products to protect fire and security equipment from theft and damage.<br />
Stock holding and supply of third <strong>part</strong>y fire and security equipment.<br />
Salisbury Glass Centre Limited<br />
Newton Road, Churchfields Industrial Estate, Salisbury, Wiltshire SP2 7QA, United Kingdom<br />
Tel: +44 (0)1722 342900 • Fax: +44 (0)1722 338784<br />
E-mail: commercialenquiries@salisbury-glass.com or domesticenquiries@salisbury-glass.com • Website:<br />
www.salisbury-glass.com<br />
Quality System Cert. No. 947 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture, installation and service of aluminium and UPVC windows, doors, conservatories and glazed sealed units.<br />
Sanwa Yoshida (JiaXing) Construction Material Industry Co., Ltd<br />
South Xitang Town, Jiashan County, Jiaxing City, Zheijang Province, China<br />
Tel: +86-573-4565888 • Fax: +86-573-84565988<br />
E-mail: megaboard@yahoo.cn • Website: www.yangmega.net<br />
Quality System Cert. No. 983 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of non-combustable high performance building board.<br />
SAPAG Industrial Valves<br />
2 Rue du Marais, 80400 Ham, France<br />
Tel: +33 (0)323 810582 • Fax: +33 (0)323 814300<br />
Quality System Cert. No. 571 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of butterfly valves for fire protection systems application.<br />
Saudi Factory For Fire Equipment Co.<br />
New Industrial Area, PO Box 58469, Riyadh 11515, Kingdom of Saudi Arabia<br />
Tel: +966 1 265 0070 • Fax: +966 1 265 2190<br />
E-mail: qa@sffeco.com.sa • Website: www.sffeco.com<br />
Quality System Cert. No. 403 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, installation, maintenance, repair and servicing of fire extinguishing systems. Design, installation and maintenance<br />
of fire detection and alarm systems. Manufacture, installation, repair and servicing of portable fire extinguishers, hose reels and cabinets.<br />
Assembly of fire pumps, hydrants and controllers for fire pumps. Manufacture of fire doors.<br />
602 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Schlumberger Oilfield UK PLC, Sensor Highway Limited (Schlumberger,<br />
Southhampton)<br />
Unit 7, The Quadrangle, Abbey Park Industrial Estate, Romsey, Southampton, Hampshire SO51 9DL, United<br />
Kingdom<br />
Tel: +44 (0)1794 529600 • Fax: +44 (0)1794 514931<br />
Website: www.slb.com<br />
Also at:<br />
Unit 5, The Quadrangle, Abbey Park Industrial Estate, Romsey, Hampshire SO51 9DL, United Kingdom<br />
and<br />
Unit 8, The Quadrangle, Abbey Park Industrial Estate, Romsey, Hampshire SO51 9DL, United Kingdom<br />
Quality System Cert. No. 648 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and repair of distributed temperature sensor devices.<br />
Scotshield Limited<br />
Century House, Chapelhall Industrial Estate, Airdrie, Scotland ML6 8QH, United Kingdom<br />
Tel: +44 (0)1236 767788 • Fax: +44 (0)1236 762233<br />
E-mail: sales@scotshield.com<br />
Quality System Cert. No. 614 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, commissioning and maintenance of fire detection systems.<br />
Security Blinds Limited<br />
Units 3 A/B, Hope Street, Thornhill Industrial Estate, Rotherham S60 1LH, United Kingdom<br />
Tel: +44 (0)1709 363535 • Fax: +44 (0)1709 364512<br />
E-mail: info@securityblinds.co.uk • Website: www.securityblinds.co.uk<br />
Quality System Cert. No. 854 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of security blinds.<br />
Sekisui Aqua Systems Company Limited<br />
77 Kami-Onogo, Iwata City, Shizuoka Prefecture 438, Japan<br />
Tel: +81 5 3835 0101 • Fax: +81 5 3836 2229<br />
Website: www.sps-int.com<br />
Quality System Cert. No. 242 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of GRP <strong>section</strong>al water storage tanks.<br />
20 Nov 2011 603
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Select Fire Services Limited<br />
10 Harolds Road, Harlow, Essex CM19 5BJ, United Kingdom<br />
Tel: +44 (0)1279 641979 • Fax: +44 (0)1279 641978<br />
E-mail: info@selectfire.co.uk • Website: www.selectfire.co.uk<br />
Quality System Cert. No. 479 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Selectaglaze Limited<br />
Alban Park, Hatfield Road, St Albans, Hertfordshire AL4 0JJ, United Kingdom<br />
Tel: +44 (0)1727 837271 • Fax: +44 (0)1727 844053<br />
E-mail: enquiries@selectaglaze.co.uk • Website: www.selectaglaze.co.uk<br />
Quality System Cert. No. 683 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, installation and service of secondary glazing systems.<br />
Selectamark Security Systems plc<br />
1 Locks Court, 429 Crofton Road, Locksbottom, Kent BR6 8NL, United Kingdom<br />
Tel: +44 (0)1689 860757 • Fax: +44 (0)1689 860693<br />
E-mail: sales@selectamark.co.uk • Website: www.selectadna.co.uk<br />
Quality System Cert. No. 497 Assessed to ISO 9001:2008<br />
Scope:<br />
The manufacture and supply of property marking systems incorporating chemical etching, forensic marking, electronic identification and<br />
secure asset registration using electronic and hard copy systems.<br />
Shaanxi J & R Fire Fighting Co Ltd<br />
Qingyang International Building, No 65, Keji 2nd Road, Gaoxin District, Xi'an, Shaanxi 710075, China<br />
Tel: +86 29 88332970 • Fax: +86 29 88332680<br />
E-mail: sales@xajr.com • Website: www.xajr.com<br />
Factory:<br />
No. 23, South of Weiyang Road, Jinwei New City, Economic and Technologic Development Zone, Xi'an,<br />
Shaanxi, China<br />
Quality System Cert. No. 1049 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and after service of gas (aerosol) fire-extinguishing systems, accessories and fittings.<br />
Shakun Polymers Limited<br />
(Cable Division), Plot No. 4, Silver Industrial Estate, Bhimpore, Patalia Road, Daman 396 210, India<br />
Tel: +91 260 222 1538 • Fax: +91 260 222 1199<br />
E-mail: technical@shakunpolymers.com • Website: www.shakuncables.com<br />
Quality System Cert. No. 978 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacturing of insulated fire resistant wires and cables.<br />
604 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Shellcast Systems Limited<br />
Camel House, Six Ashes, Bridgnorth WV15 6ER, United Kingdom<br />
Tel: +44 (0)1562 750 700 • Fax: +44(0)8712 453 553<br />
E-mail: technical@shellcast-shutters.co.uk • Website: www.shellcast-shutters.co.uk<br />
Quality System Cert. No. 707 Assessed to ISO 9001:2008<br />
Scope:<br />
Supply, installation, commissioning, service and repair of security shutters.<br />
ShenZhen CICAM Manufacturing Co Ltd<br />
Building 11, Wanxia Industry Garden, Tongfuyu Industry District, Shajing Street, Bao An District, Shenzhen<br />
518104, China<br />
Tel: +852 2596 7711 • Fax: +852 2586 1600<br />
E-mail: sherva.chung@dtechnology.com.hk<br />
Quality System Cert. No. 668 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of radioactive based industrial and domestic smoke detection ionization chambers and components.<br />
Manufacture of industrial and domestic smoke alarms and associated products.<br />
Shurjoint Metals Inc.<br />
No 295, Sec 3, Wantan Road, Wantan Township, Pingtung County, Taiwan ROC<br />
Tel: +886 8 752 5877 • Fax: +886 8 753 0227<br />
Quality System Cert. No. 448 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of pipe couplings and fittings.<br />
Siemens plc, Building Technologies, Fire Safety Division<br />
Brunel House, Sir William Siemens Square, Frimley, Camberley, Surrey GU16 8QD, United Kingdom<br />
Tel: +44 (0)1276 696000 • Fax: +44 (0)1276 696133<br />
E-mail: sales.uk.sbt@siemens.com • Website: www.siemens.co.uk/buildingtechnologies<br />
Also at:<br />
7th Floor, Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock, Staffordshire WS11 0XE,<br />
United Kingdom<br />
Tel: +44 (0)1543 435500 • Fax: +44 (0)1543 435525<br />
Quality System Cert. No. 616 Assessed to ISO 9001:2008<br />
Scope:<br />
Frimley:- Design, installation, commissioning and servicing of fire detection, alarm systems and gaseous fire extinguishing systems.<br />
Service and maintenance of fire sprinkler, deluge, water spray, foam, hose reels and hydrants.<br />
Cannock:- Design, installation, commissioning and servicing of fire detection, alarm systems and gaseous fire extinguishing systems.<br />
Maintenance of portable fire extinguishers.<br />
20 Nov 2011 605
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Siemens Switzerland Limited, Building Technologies Division<br />
International Headquarters, Gubelstrasse 22, CH-6301 Zug, Switzerland<br />
Tel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22<br />
Quality System Cert. No. 126 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm equipment and electronic security equipment. Design and assembly of fire<br />
extinguishing equipment.<br />
The following locations are included within the scope of certification:-<br />
Factory Volketswil<br />
CH-8604 Volketswil, Switzerland<br />
Factory Altenrhein<br />
CH-9423 Altenrhein, Switzerland<br />
Factory Buc<br />
F-78531 Buc, France<br />
Scope:<br />
Manufacture and repair of fire and security detection and alarm systems and components.<br />
The following location is included within the scope of certification:-<br />
Factory Berlin<br />
D-13629 Berlin, Germany<br />
SigNET AC Limited<br />
6 Tower Road, Glover Industrial Park, Washington, Tyne & Wear NE37 2SH, United Kingdom<br />
Tel: +44 (0)191 417 4551 • Fax: +44 (0)191 417 0634<br />
E-mail: sales@signet-ac.com • Website: www.signet-ac.co.uk<br />
Quality System Cert. No. 1082 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of voice/PA equipment; audio frequency induction loop equipment. Disabled refuge emergency evacuation equipment.<br />
Simbars (UK) Limited<br />
Unit 2, 46 Ashton Vale Road, Ashton, Bristol BS3 2HQ, United Kingdom<br />
Tel: +44 (0)117 953 1444 • Fax: +44 (0)117 963 1444<br />
E-mail: info@simbars.co.uk • Website: www.simbars.co.uk<br />
Quality System Cert. No. 932 Assessed to ISO 9001:2008<br />
Scope:<br />
The design, manufacture and installation of water borehole security kiosks including enclosures and gates. Fabrication of small and<br />
medium sized metal products used as street furniture for security and pedestrian use.<br />
606 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
SMP Security Limited<br />
Halesfield 24, Telford, Shropshire TF7 4NZ, United Kingdom<br />
Tel: +44 (0)1952 585673 • Fax: +44 (0)1952 582816<br />
E-mail: sales@smpsecurity.co.uk • Website: www.smpsecurity.co.uk<br />
Quality System Cert. No. 115 Assessed to ISO 9001:2008<br />
Scope:<br />
The design, manufacture and installation of secure storage enclosures, strongroom doors, associated products and services.<br />
Solent Fire Protection Services Limited<br />
12 Heritage Business Park, Heritage Way, Gosport, Hampshire PO12 4BG, United Kingdom<br />
Tel: +44 (0)2392 510230 • Fax: +44 (0)2392 511510<br />
E-mail: info@solentfire.co.uk • Website: www.solentfire.co.uk<br />
Quality System Cert. No. 220 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Sotech Limited<br />
2 Traynor Way, Whitehouse Business Park, Peterlee, County Durham SR8 2RU, United Kingdom<br />
Tel: +44 (0)191 587 2287 • Fax: +44 (0)191 518 0703<br />
E-mail: mail@sotech-optima.co.uk • Website: www.sotech-optima.co.uk<br />
Quality System Cert. No. 770 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of rain screen cladding panels, louvre units, gutter flashings, fascia and soffit details and bent metal components for<br />
construction. Sub-contract metal bending.<br />
Southern Grille & Gate Limited<br />
Unit 4, Eagle Trading Estate, 29 Willow Lane, Mitcham, Surrey CR4 4UY, United Kingdom<br />
Tel: +44 (0)208 640 9989 • Fax: +44 (0)208 640 4108<br />
E-mail: sales@sgg-ltd.co.uk • Website: www.sgg-ltd.co.uk<br />
Quality System Cert. No. 1037 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacutre of steel doorsets and collapsible gates, roller shutters and grilles.<br />
Spears Manufacturing Company Inc<br />
15853 Olden Street, Sylmar, California 91342, United States<br />
Tel: +1 818 364 1611 • Fax: +1 818 364 6945<br />
Website: www.spearsmfg.com<br />
Quality System Cert. No. 293 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of injection moulded pipe fittings and valves.<br />
20 Nov 2011 607
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Specialist Panels UK Limited<br />
Bolam Business Park, Bassington Drive, Bassington Industrial Estate, Cramlington, Northumberland NE23<br />
8AD, United Kingdom<br />
Tel: +44(0) 1670 739116 • Fax: +44(0) 1670 732955<br />
E-mail: isowall@btinternet.com • Website: www.isowall.org.uk<br />
Quality System Cert. No. 957 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of structural insulated panels.<br />
SPIE Fire (A division of SPIE)<br />
7-14 Great Dover Street, London SE1 4YR, United Kingdom<br />
Tel: +44 (0)20 7089 7350 • Fax: +44 (0)20 7089 7378<br />
E-mail: fire.engineering@spiematthewhall.com • Website: www.spiematthewhall.com<br />
Quality System Cert. No. 070 Assessed to ISO 9001<br />
Scope:<br />
Design, installation and servicing of fire sprinkler and water spray systems. Design and installation of fire detection systems.<br />
SPIE Fire (A division of SPIE)<br />
Unit 2, Focus Park, Ashbourne Way, Solihull, West Midlands B90 4QU, United Kingdom<br />
Tel: +44 (0)121 713 8113 • Fax: +44 (0)121 713 8198/8199<br />
E-mail: fire.engineering@spiematthewhall.com • Website: www.spiematthewhall.com<br />
Quality System Cert. No. 070-2 Assessed to ISO 9001<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems. Small works and servicing of fire detection systems.<br />
SPIE Matthew Hall<br />
Level 2, McCafferty House, 99 Firhill Road, Glasgow G20 7BE, United Kingdom<br />
Tel: +44 (0)141 945 8900 • Fax: +44 (0)141 945 8901<br />
E-mail: fire.engineering@spiematthewhall.com • Website: www.spiematthewhall.com<br />
Quality System Cert. No. 986 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, project management, installation and commissioning of fire suppression systems.<br />
608 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
SPP Pumps Limited<br />
Sales & Services:<br />
Theale Cross, Pincents Lane, Calcot, Reading, Berkshire RG31 7SP, United Kingdom<br />
Tel: +44 (0)118 932 3123 • Fax: +44 (0)118 932 3302<br />
E-mail: solutions@spppumps.com • Website: www.spppumps.com<br />
Design & Manufacture:<br />
Crucible Close, Muschet Industrial Park, Coleford, Gloucestershire GL16 8PS, United Kingdom<br />
Quality System Cert. No. 111 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of pumps, pump packages and generator sets, for use in construction, building services, oil and gas, and<br />
water industries, as well as general industry. Project management and the assembly of pump packages and generators including<br />
associated documentation. Service and provision of spare <strong>part</strong>s, repair and maintenance of pumps, valves, compressors and other allied<br />
equipment.<br />
The following locations are included within the scope of certification:-<br />
Service Centres:<br />
Tufthorn Avenue, Coleford, Gloucestershire GL16 8PS UK<br />
Unit 1, Stanstead Road, Eastleigh, Hampshire SO50 4RZ UK<br />
Greg Street, Reddish, Stockport, Cheshire SK5 7BU UK<br />
Unit 2, Oakbank, Channel Commercial Park, Queens Road, Belfast, Northern Ireland BT3 9DT<br />
Scope:<br />
Installation, service and repair of fire pumps, pump packages and valves.<br />
PO Box 61491, Jebel Ali, Dubai, United Arab Emirates<br />
Scope:<br />
Testing and supply of LPCB approved fire pump sets.<br />
SPP Pumps Inc., 6716 Best Friend Road, Norcross, GA 30071, United States of America<br />
Scope:<br />
Supply and testing of pumps and pump sets.<br />
SPP Pumps (South Africa) (Pty), 6c Roller Street, S<strong>part</strong>an Extension 7, Kempton Park, Gauteng, Johannesburg, RSA.<br />
Scope:<br />
Supply, manufacture and repair of pumps and pump sets.<br />
Sprue Safety Products Ltd<br />
Vanguard Centre, Sir William Lyons Road, Coventry CV4 7EZ, United Kingdom<br />
Tel: +44 (0)2476 323232 • Fax: +44 (0)2476 693610<br />
E-mail: info@fireangel.co.uk • Website: www.fireangel.co.uk<br />
Quality System Cert. No. 651 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and supply of domestic photo-electric, ionization smoke detectors and CO alarms.<br />
20 Nov 2011 609
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Stanair Industrial Door Services Limited<br />
2 Henson Way, Telford Way Industrial Estate, Kettering, Northamptonshire NN16 8PX, United Kingdom<br />
Tel: +44 (0)1536 482187 • Fax: +44 (0)1536 411799<br />
E-mail: info@stanair.co.uk • Website: www.stanair.co.uk<br />
Also at:<br />
Unit 11, Blundells Road, Bradville, Milton Keynes MK13 7HA, United Kingdom<br />
Tel: +44 (0)1908 222070 • Fax: +44 (0)1908 222621<br />
Quality System Cert. No. 141 Assessed to ISO 9001:2008<br />
Scope:<br />
Installation, servicing and repair of industrial doors and fire doors. Installation, servicing and repair of industrial rolling shutters and fire<br />
rolling shutters.<br />
Stancold plc<br />
Portview Road, Avonmouth, Bristol BS11 9LQ, United Kingdom<br />
Tel: +44 (0)117 316 7000 • Fax: +44 (0)117 316 7001<br />
E-mail: sales@stancold.co.uk • Website: www.stancold.co.uk<br />
Quality System Cert. No. 600 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, supply and installation of composite insulation and fire retardant panels and panel systems.<br />
Static Systems Group Plc<br />
Heath Mill Road, Wombourne, Staffordshire WV5 8AN, United Kingdom<br />
Tel: +44 (0)1902 895551 • Fax: +44 (0)1902 324969<br />
E-mail: sales@staticsystems.co.uk • Website: www.staticsystems.co.uk<br />
Quality System Cert. No. 053 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire alarm systems. Installation, commissioning and servicing of fire detection and alarm systems.<br />
Steeltech Systems Limited<br />
Baris House, Nunn Brook Road, County Estate, Huthwaite, Nottinghamshire NG17 2HU, United Kingdom<br />
Tel: +44 (0)1623 441442 • Fax: +44(0)1623 441443<br />
Quality System Cert. No. 985 Assessed to ISO 9001:2008<br />
Scope:<br />
The design and fabrication of Dryvit Fedderlite External Thermal-Insulated Cladding (ETIC) System Panels.<br />
STO AG<br />
Ehrenbachstrasse 1, D-79780, Stuhlingen, Germany<br />
Tel: +49 7744 571440 • Fax: +49 7744 572440<br />
Quality System Cert. No. 749 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
External wall insulation systems plasters, concrete restoration and paints.<br />
610 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Sunjüt A.S.<br />
Manufacturing Plant:<br />
Yesilbayir Mah, Hadimköy Istanbul yolu Cad. No: 59, 34555 P.K Arnavutköy Hadimköy, Istanbul, Turkey<br />
Tel: +90 216 365 3950 • Fax: +90 216 365 0663<br />
Quality System Cert. No. 495 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of flame retardant woven material.<br />
Sunray Engineering Limited<br />
Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL, United Kingdom<br />
Tel: +44 (0)1233 639039 • Fax: +44 (0)1233 625137<br />
E-mail: sales@sunraydoors.co.uk • Website: www.sunraydoors.co.uk<br />
Quality System Cert. No. 234 Assessed to ISO 9001:2008<br />
Scope:<br />
The design, manufacture, supply and installation of steel security doors, fire doors, commercial doors, industrial doors and louvre<br />
systems.<br />
Supra UK Limited<br />
24 The Furlong, Berry Hill Industrial Estate, Droitwich Spa, Worcestershire WR9 9AH, United Kingdom<br />
Tel: +44 (0)1905 770333 • Fax: +44 (0)1905 797773<br />
E-mail: sales@keysafe.co.uk • Website: www.keysafe.co.uk<br />
Quality System Cert. No. 1004 Assessed to ISO 9001:2008<br />
Scope:<br />
Distribution and installation of key safes and cabinets.<br />
Sure Lock Doors Limited<br />
Unit 4, Monarch Industrial Estate, 198 Kings Road, Tyseley, Birmingham, West Midlands B11 2AP, United<br />
Kingdom<br />
Tel: +44 (0)121 706 8400 • Fax: +44 (0)121 706 4399<br />
E-mail: sales@surelockdoors.co.uk • Website: www.surelockdoors.co.uk<br />
Quality System Cert. No. 1045 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of high security stainless steel and aluminium doors, door sets and interlocking systems.<br />
20 Nov 2011 611
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Surelock McGill Group<br />
Incorporating:<br />
Surelock McGill Ltd, 25/26 The Business Centre, Molly Millars Lane, Wokingham, Berks RG41 2QY, United<br />
Kingdom<br />
and<br />
Stafford Bridge Doors Ltd, Beford Road, Pavenham, Bedfordshire MK43 7OS, United Kingdom<br />
Quality System Cert. No. 516 Assessed to ISO 9001:2008<br />
Scope:<br />
McGill Ltd, Wokingham:<br />
Design and manufacture of single point and multi point bolting and locking systems, heavy duty hinges and related equipment for fire,<br />
safety, security, blast and acoustic doors, windows, panels and hatches.<br />
Stafford Bridge Doors Ltd, Pavenham:<br />
Design, manufacture, supply and installation of security doors and door sets.<br />
SuZhou Primetech Electronics Co Limited<br />
ChunFeng Road, Pan Yang Industrial Park, HuangDai Town, Xiang Cheng District, SuZhou City, JiangSu,<br />
China<br />
Tel: +86 512 6571<br />
E-mail: frankybliu@hotmail.com • Website: www.primetech-sz.com.cn<br />
Quality System Cert. No. 971 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and repair of smoke, heat and gas detection alarms for domestic use.<br />
SWS UK<br />
Hornby Road, Claughton, Lancaster LA2 9LA, United Kingdom<br />
Tel: +44 (0)1524 772400 • Fax: +44 (0)1524 772411<br />
E-mail: info@swsuk.co.uk • Website: www.swsuk.co.uk<br />
Quality System Cert. No. 390 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture, installation and repair of industrial shutters, collapsible gates and window bars.<br />
System Sensor<br />
3825 Ohio Avenue, Saint Charles, Illinois 60174, United States<br />
Tel: +1 630 377 6580 • Fax: +1 630 377 7245<br />
Website: www.systemsensor.com<br />
Quality System Cert. No. 118 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture of fire detection and alarm system components. Design and manufacture of waterflow alarm switches.<br />
612 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
System Sensor de México S.A. de C.V.<br />
Ave. Valle del Cedro No. 1681, Parque Industrial Intermex, Ciudad Juárez, Chihuahua, CP 32574, Mexico<br />
Tel: +52 656 6240479 • Fax: +52 656 6240490<br />
Website: www.systemsensor.com<br />
USA Office:<br />
Tel: +1 630 443 4242 • Fax: +1 630 443 4247<br />
Quality System Cert. No. 859 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm system components. Manufacture of gas detection devices.<br />
System Sensor Fire Detectors<br />
Volochaevskaya Ulitsa, 40 Building 2, 111033 Moscow, Russian Federation<br />
Tel: +7 495 937 7985 • Fax: +7 495 937 7983<br />
E-mail: Moscow@systemsensor.com<br />
Quality System Cert. No. 585 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture and servicing of fire detection and alarm system components.<br />
System Sensor, Honeywell International (I) PVT. Limited<br />
Sector 36, Pace City - II, Gurgaon - 122 004, Haryana, India<br />
Tel: +91 124 6371770 • Fax: +91 124 6371713<br />
E-mail: anil.chugh@honeywell.com<br />
Quality System Cert. No. 550 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of fire detection and alarm system components.<br />
Talentum Developments Limited<br />
Beal Lane, Shaw, Oldham, Lancashire OL2 8PF, United Kingdom<br />
Tel: +44 (0)1706 844714 • Fax: +44 (0)1706 882612<br />
E-mail: info@talentum.co.uk • Website: www.talentum.co.uk<br />
Quality System Cert. No. 729 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and repair of spark and flame detectors.<br />
TangoRail Limited<br />
Units 1-3,, Prothero Industrial Estate, Bilport Lane, Wednesbury, West Midlands WS10 0NT, United Kingdom<br />
Tel: +44 (0)844 8360008 • Fax: +44 (0)844 8360009<br />
E-mail: info@tangorail.com • Website: www.tangorail.com<br />
Quality System Cert. No. 942 Assessed to ISO 9001:2008<br />
Scope:<br />
Supply of security fencing.<br />
and<br />
20 Nov 2011 613
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Herons Way, Balby, Doncaster, DN4 8WA<br />
Scope:<br />
Design, manufacture and supply of security fencing systems.<br />
Taylor Fire Sprinklers Limited<br />
Unit D, Avondale Way, Wakefield, West Yorkshire WF2 7QU, United Kingdom<br />
Tel: +44 (0)1924 375971 • Fax: +44 (0)1924 609902<br />
E-mail: info@taylorfiresprinklers.co.uk • Website: www.taylorfiresprinklers.co.uk<br />
Quality System Cert. No. 990 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Technocover Limited (incorporating TechnoRail and Strataform)<br />
Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom<br />
Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527<br />
E-mail: techadvice@technocover.co.uk • Website: www.technocover.co.uk<br />
Quality System Cert. No. 450 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of access covers, doors, gratings, grilles, security enclosures, gas cylinder security devices and<br />
access systems including flooring, decking, support steel and hand railing.<br />
Terofire Products<br />
Lion House, Lion Street, Congleton, Cheshire CW12 4BH, United Kingdom<br />
Tel: +44 (0)1260 297 578 • Fax: +44 (0)1260 290 078<br />
E-mail: sales@terofire.com • Website: www.terofire.com<br />
Quality System Cert. No. 799 Assessed to ISO 9001:2008<br />
Scope:<br />
Stockholding and supply of fire alarm control and indicating equipment. Repair of control and indicating equipment.<br />
Thameside Fire Protection Co. Limited<br />
Unit 4, Sovereign Business Park, Cranes Farm Road, Basildon, Essex SS14 3JD, United Kingdom<br />
Tel: +44 (0)1268 597999 • Fax: +44 (0)1268 597998<br />
E-mail: enquiries@thamesidefire.co.uk • Website: www.thamesidefire.co.uk<br />
Quality System Cert. No. 269 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems. Installation, repair and servicing of portable fire extinguishers. Fire alarm<br />
installation and servicing.<br />
The Reliable Automatic Sprinkler Co., Inc,<br />
1470 Smith Grove Road, Liberty, South Carolina 29657, United States<br />
Tel: +1 864 843 1734 • Fax: +1 864 843 1418<br />
E-mail: jcevallos@reliablesprinkler.com • Website: www.reliablesprinkler.com<br />
Quality System Cert. No. 034 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire sprinklers, alarm, dry and deluge valves and related products for fire sprinkler systems.<br />
614 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
The Rooflight Company<br />
Wychwood Business Centre, Milton Road, Shipton-under-Wychwood, Oxfordshire OX7 6XU, United Kingdom<br />
Tel: +44 (0)1993 833108 • Fax: +44 (0)1993 831066<br />
E-mail: info@therooflightcompany.co.uk • Website: www.therooflightcompany.co.uk<br />
Also at:<br />
Bourton Industrial Park, Bourton on the Water, Gloucestershire GL54 2HQ, United Kingdom<br />
Quality System Cert. No. 929 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture, storage and distribution of pitched and flat rooflights.<br />
The Viking Corporation<br />
210 N Industrial Park, Hastings, Michigan 49058, United States<br />
Tel: +1 269 945 9501 • Fax: +1 269 945 9599<br />
E-mail: techsvcs@vikingcorp.com • Website: www.vikingcorp.com<br />
Also at:<br />
11305 James Street, Holland, Michigan 49424, United States<br />
Quality System Cert. No. 096 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire sprinklers, fire protection valves and related products for fire sprinkler systems.<br />
Thermotech Fire Protection Limited<br />
Unit 10, Bamford Business Park, Off Hibbert Street, Reddish, Stockport SK4 1PL, United Kingdom<br />
Tel: +44 (0)161 476 5551 • Fax: +44 (0)161 476 2998<br />
E-mail: info@thermotech-fireprotection.co.uk • Website: www.thermotech-fireprotection.co.uk<br />
Quality System Cert. No. 829 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation and servicing of fire sprinkler systems.<br />
Tindall Engineering Limited<br />
Abryll House, Wright Street (off Yorkshire Street), Oldham, Lancashire OL1 3TF, United Kingdom<br />
Tel: +44 (0)161 620 0666 • Fax: +44 (0)161 620 3966<br />
Quality System Cert. No. 608 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of the MICO range of emergency exit hardware and high security multi-point locking hardware.<br />
Total Polyfilm Limited<br />
Armytage Road, The Industrial Estate, Brighouse, West Yorkshire HD6 1PT, United Kingdom<br />
Tel: +44 (0)1484 714313 • Fax: +44 (0)1484 720452<br />
Quality System Cert. No. 527 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture and supply of low density flame retardant polythene sheeting.<br />
20 Nov 2011 615
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Tratos Cavi SpA<br />
Via Stadio 2, Pieve S. Stefano 52036, Arezzo, Italy<br />
Tel: +39 0575 7941 • Fax: +39 0575 798026<br />
E-mail: direzione@tratos.it • Website: www.tratos.it<br />
Quality System Cert. No. 222 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of electric cables for use in fire alarm systems.<br />
Trellicor (Pty) Limited<br />
20 Aberdare Drive, Phoenix Industrial Park, Durban, South Africa<br />
Tel: +27 31 500 4301 • Fax: +27 31 507 2129/3973<br />
Quality System Cert. No. 474 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of sliding security gates.<br />
Trimetals Limited<br />
Sunrise Business Park, Higher Shaftesbury Road, Blandford Forum, Dorset DT11 8ST, United Kingdom<br />
Tel: +44 (0)1258 459441 • Fax: +44 (0)1258 480408<br />
E-mail: sales@trimetals.co.uk • Website: www.trimetals.co.uk<br />
Quality System Cert. No. 899 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Design and manufacture of bicycle stores.<br />
Twinplast Limited<br />
Unit 2, Greycaine Road, Watford, Hertfordshire WD24 7GP, United Kingdom<br />
Tel: +44 (0)1923 230191/817761 • Fax: +44 (0)1923 817756<br />
E-mail: sales@twinplast.co.uk • Website: www.twinplast.co.uk<br />
Quality System Cert. No. 375 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of polypropylene twinwall sheet and associated conversion products.<br />
Tyco Building Services Products B.V.<br />
Kopersteden 1, 7547 TJ Enschede, The Netherlands<br />
Tel: +31 53 4284444 • Fax: +31 53 4283377<br />
E-mail: info-NL@tyco-bspd.com • Website: www.tycobuilding.com<br />
Quality System Cert. No. 169 Assessed to ISO 9001:2008<br />
Scope:<br />
Scope:<br />
Stockholding, supply and distribution of fire protection equipment including:<br />
-Sprinklers, valves and accessories<br />
-Hydrants, foam extinguishing system components<br />
-Pipe couplings, fittings and hangers<br />
-Metal framing and support systems to distributors and the construction industry<br />
-Assembly and test of fire protection valve stations<br />
616 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Central Spraysafe / Spraysafe Automatic Sprinklers Limited<br />
Unit 6, Westpoint Enterprise Park, Clarence Avenue, Trafford Park, Manchester M17 1QS, UK<br />
Tel: +44 (0)161 875 0400 Fax: +44 (0)161 875 0491<br />
Scope:<br />
Supply of fire protection equipment. Assembly and pressure test of valve stations.<br />
Tyco Fire & Building Products<br />
Research & Development Center, 1467 Elmwood Avenue, Cranston, RI 02910, United States<br />
Tel: +1 401 781 8220 • Fax: +1 401 781 7317<br />
Quality System Cert. No. 570 Assessed to ISO 9001:2008<br />
Scope:<br />
Research, design, development and manufacturing support for the fire protection equipment, pipe couplings, fittings, related piping<br />
system components and CPVC pipe and fitting manufactures of Tyco Fire and Building Products.<br />
Tyco Fire & Building Products<br />
8902 North Interstate 27, Lubbock, Texas 79403, United States<br />
Tel: +1 806 472 2400 • Fax: +1 806 806 8902<br />
Quality System Cert. No. 094-2 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of fire sprinklers and sprayers.<br />
Tyco Fire & Building Products<br />
245 Swancott Road, Madison, Alabama 35756, United States<br />
Tel: +1 256 464 5633 • Fax: +1 256 464 5635<br />
Quality System Cert. No. 420 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of CPVC pipe and fittings.<br />
Tyco Fire & Building Products<br />
260 Central Castings Drive, Anniston, AL 36206, United States<br />
E-mail: info-uk@tyco-bspd.com • Website: www.tycobuilding.com<br />
Quality System Cert. No. 669 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of pipe couplings, fittings, related piping systems components and castings.<br />
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated<br />
Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)<br />
Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL, United Kingdom<br />
Tel: +44 (0)161 205 2321 • Fax: +44 (0)161 455 4459<br />
Website: www.tycofis.com<br />
Quality System Cert. No. 014 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, servicing and inspection of fire sprinklers, detection, deluge, water spray, foam and gas suppression systems.<br />
The following locations are included within the scope of certification:-<br />
20 Nov 2011 617
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Belfast<br />
Tyco House, 13a Airport Road West, Belfast, Northern Ireland BT8 9ED<br />
Birmingham<br />
Hawthorns Business Centre, Halfords Lane, Smethwick, Warley, West Midlands B66 1DW<br />
Bristol<br />
1610 Park Avenue, Aztec West, Almondsbury, Bristol BS32 4UA<br />
Dudley<br />
Hillcrest Business Park, Cinderbank, Dudley, West Midlands DY2 9AP<br />
Manchester<br />
Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL<br />
Slough<br />
Tyco House, 57-63 Farnham Road, Slough, Berkshire SL1 3TN<br />
Swansea<br />
Tyco House, Phoenix Way, Swansea SA7 9EQ<br />
Scope:<br />
Design, installation, servicing and inspection of fire sprinklers, water spray and foam systems.<br />
The following locations are included within the scope of certification:-<br />
East Kilbride<br />
30-32 Singer Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0XS<br />
Newcastle<br />
6 Stirling Court, Eleventh Avenue North, Team Valley Trading Estate, Gateshead, Tyne & Wear NE11 0JF<br />
Scope:<br />
Manufacture, installation, servicing and repair of industrial rolling shutters, fire doors, fire rolling shutters and glazed automatic doors.<br />
The following locations are included within the scope of certification:-<br />
Barnsley (Doors)<br />
Albion Road, Carlton Industrial Estate, Barnsley, South Yorkshire S71 3HW<br />
Manchester (Doors)<br />
Tyco Park, Newton Heath, Manchester M40 2WL<br />
Wigan (Doors)<br />
Unit 4, Bradley Hall Trading Estate, Bradley Lane, Standish, Wigan, Lancashire WN6 OXQ<br />
Scope:<br />
The contract service and maintenance of portable fire extinguishers within the UK, at each location and in accordance with BS 5306:3,<br />
BS 5306:8.<br />
The following locations are included within the scope of certification:-<br />
Crayford<br />
Unit L, Acorn Business Park, Crayford, DA1 4FL<br />
East Kilbride<br />
30-32 Singer Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0XS<br />
Birmingham<br />
Hawthorns Business Centre, Halfords Lane, Smethwick, Warley, West Midlands B66 1DW<br />
618 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Manchester<br />
Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL<br />
Tyco Fire Products Manufacturing Limited<br />
Stockport Trading Estate, Yew Street, Stockport, Cheshire SK4 2JW, United Kingdom<br />
Tel: +44 (0)161 429 3400 • Fax: +44 (0)161 477 6729<br />
E-mail: tycofireproducts.uk@tyco-bspd.com • Website: www.tycobuilding.com<br />
Sales Enquiries:<br />
Tel: +44 (0)161 8750400 • Fax: +44 (0)161 8750491<br />
Quality System Cert. No. 007 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire protection valves, fire sprinklers, high and medium velocity nozzles and controls. Design, manufacture<br />
and assembly of foam and gas fire extinguishing systems. Manufacture of fusible links.<br />
Tyco Flow Control (M) Sdn. Bhd. (Tyco Fire Suppression & Building Products,<br />
Malaysia)<br />
Lot 886, C1 & C2,, Jalan Subang 9, Taman Perindustrian Subang, 47500 Subang, Selangor, Malaysia<br />
E-mail: info-uk@tyco-bspd.com • Website: www.tycobuilding.com<br />
Quality System Cert. No. 673 Assessed to ISO 9001:2008<br />
Scope:<br />
Assembly of couplings and marketing of couplings and fittings.<br />
Tyco Thermal Controls UK Ltd<br />
3 Rutherford Road, Stephenson Industrial Estate, Washington, Tyne & Wear NE37 3HX, United Kingdom<br />
Tel: +44 (0)191 419 8200 • Fax: +44 (0)191 419 8201<br />
E-mail: jjones@tycothermal.com • Website: www.tycothermal.com<br />
Quality System Cert. No. 063 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and supply of mineral insulated and flexible cables and assemblies for use in heating, temperature measurement,<br />
wiring, displacement measurement, leak detection, signal transmittal and nuclear applications. Design, supply and installation of heat<br />
tracing systems.<br />
UK Fire Safety Limited<br />
13-15 Lostock Road, Urmston, Manchester M41 0ES, United Kingdom<br />
Tel: +44 (0)161 746 8037 • Fax: +44 (0)161 746 8136<br />
E-mail: mroyle@uk-firesafety.co.uk • Website: www.uk-firesafety.co.uk<br />
Quality System Cert. No. 856 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, supply, installation, servicing and commissioning of fire sprinkler systems.<br />
20 Nov 2011 619
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
UK Firewatch Limited<br />
10 Apollo Court, Koppers Way, Monkton Business Park South, Hebburn, Tyne & Wear NE31 2ES, United<br />
Kingdom<br />
Tel: +44 (0)191 495 9525 • Fax: +44 (0)191 495 9529<br />
E-mail: enquiries@ukfirewatch.com • Website: www.ukfirewatch.com<br />
Quality System Cert. No. 391 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, fabrication, installation and maintenance of fixed fire protection systems.<br />
UK Firewatch Limited<br />
37/39 Manor Road, Romford, Essex RM1 2TL, United Kingdom<br />
Tel: +44 (0)1708 756248 • Fax: +44 (0)1708 769315<br />
E-mail: enquiries@ukfirewatch.com • Website: www.ukfirewatch.com<br />
Quality System Cert. No. 536 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, fabrication, installation and servicing of fire sprinkler and water spray systems, hydrants and hosereels.<br />
Ultra Suppression Systems Limited<br />
Oakridge House, Wellington Road, High Wycombe, Buckinghamshire HP12 3PR, United Kingdom<br />
Tel: +44 (0)1494 444123 • Fax: +44 (0)1494 444345<br />
E-mail: info@ultrass.co.uk • Website: www.ultrass.co.uk<br />
Quality System Cert. No. 752 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and project management of water mist and gaseous fire suppression systems including installation, commissioning, service and<br />
repair.<br />
Universal Fixings Limited<br />
New John Street, Halesowen, West Midlands B62 8HT, United Kingdom<br />
Tel: +44 (0)1384 422284 • Fax: +44 (0)1384 897446<br />
Quality System Cert. No. 766 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Manufacture of Filbow Hangers.<br />
UTC Fire & Security (Africa) trading as Ziton<br />
Ziton House, 555 Voortrekker Road, Maitland 7405, Cape Town, South Africa<br />
Tel: +27 21 5066000 • Fax: +27 21 5066100<br />
Website: www.utcfireandsecurity.com<br />
Quality System Cert. No. 092 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of fire detection and alarm systems and components.<br />
620 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
UTC Fire & Security Americas Corporation, Inc.<br />
129 North Main Street, Pittsfield, ME 04967, United States<br />
Tel: +1 207 487 3104 • Fax: +1 207 487 5526<br />
E-mail: leon.newsome@ge.com • Website: www.gesecurity.com<br />
8985 Town Center Parkway, Bradenton FL 34202, United States<br />
Tel: +1 941 739 4200 • Fax: +1 941 751 6384<br />
41 Woodford Avenue, Plainville CT 06062, United States<br />
Also at:<br />
Technology Center, 129 Hunnewell Avenue, Pittsfield ME 04967, United States<br />
Quality System Cert. No. 262 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and repair of fire detection, fire alarm control and indicating equipment, and customer training.<br />
UTC Fire & Security Services<br />
10 Avenue du Centaure, B.P.38408-95806, Cergy-Pontoise Cedex, France<br />
Tel: +33 1 30173737 • Fax: +33 1 30173707<br />
Website: www.chubbsecurite.com<br />
Quality System Cert. No. 747 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm system panels.<br />
Ventcroft Limited<br />
Goddard Road, Astmoor Industrial Estate, Runcorn, Cheshire WA7 1NQ, United Kingdom<br />
Tel: +44 (0)1928 581098 • Fax: +44 (0)1928 581099<br />
E-mail: sales@ventcroft.co.uk • Website: www.ventcroft.co.uk<br />
Quality System Cert. No. 682 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of electric cables for use in security alarm systems and installations that require safety in the event of fire.<br />
Victaulic Company<br />
2010 Enterprise Drive NE, Leland, North Carolina 28451, United States<br />
Tel: +1 910 371 5588 • Fax: +1 910 371 2728<br />
E-mail: victaulic@victaulic.co.uk • Website: www.victaulic.com<br />
Quality System Cert. No. 203 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of press fit pipe couplings and fittings; elastomeric gaskets and fire sprinklers and accessories.<br />
20 Nov 2011 621
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Victaulic Company<br />
4901 Kesslersville Road, Easton, Pennsylvania 18040, United States<br />
Tel: +1 610 559 3300 • Fax: +1 610 250 8817<br />
E-mail: victaulic@victaulic.com • Website: www.victaulic.com<br />
Quality System Cert. No. 104 Assessed to ISO 9001:2008<br />
Scope:<br />
Design of pipe couplings, fittings, valves, fire sprinklers, grooving tools and related accessories. Manufacture of pipe couplings, fittings,<br />
valves and related accessories.<br />
Also at:<br />
8023 Quarry Road, Alburtis, Pennsylvania 18011, USA<br />
Scope:<br />
Casting of pipe couplings, fittings and related accessories.<br />
And:<br />
1818 Vultee Street, Allentown, Pennsylvania 18103, USA<br />
Scope:<br />
Finishes of pipe couplings and fittings for the water supply industry.<br />
And:<br />
Mold Technology Centre (MTC), 2860 Bath Pike, Suite 300, Nazareth, Pennsylvania 18064, USA<br />
Scope:<br />
Design and manufacture of elastomeric molds.<br />
Viking Plastics<br />
202 Industrial Drive, Huntsville AL 35811, United States<br />
Tel: 001 256 858 3711 • Fax: 001 256 858 3775<br />
E-mail: techsvcs@viking.com • Website: www.vikingcorp.com<br />
Quality System Cert. No. 837 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of CPVC fire sprinkler pipe.<br />
Vimpex Limited<br />
Star Lane, Great Wakering, Essex SS3 0PJ, United Kingdom<br />
Tel: +44 (0) 1702 216999 • Fax: +44 (0) 1702 216699<br />
E-mail: sales@vimpex.co.uk • Website: www.vimpex.co.uk<br />
Quality System Cert. No. 456 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, sub-contract manufacture and distribution of fire alarm warning and evacuation devices, including voice-enhanced sounders and<br />
water leak detection systems. Stockholding, distribution, repair and servicing of tools for the emergency services, police and the military.<br />
Portable fire fighting equipment, telescopic masts and commercial vehicle accessories.<br />
622 20 Nov 2011
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Vipond Fire Protection Limited<br />
10-12 Glenfield Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0RA, United Kingdom<br />
Tel: +44 (0)1355 2375 25/80/88 • Fax: +44 (0)1355 263399<br />
E-mail: admin.uk@vipondltd.co.uk • Website: www.vipondfire.co.uk<br />
Quality System Cert. No. 136 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, installation, and servicing of fire sprinkler systems. Design, installation, commissioning and servicing of fire detection and alarm<br />
systems. Fabrication of pipework for the sprinkler systems and pipework for carrying fluids.<br />
Vulcan Tanks Limited<br />
Cotes Park Lane, Cotes Park Industrial Estate, Alfreton, Derbyshire DE55 4NJ, United Kingdom<br />
Tel: +44 (0)1773 835321 • Fax: +44 (0)1773 836578<br />
E-mail: info@cstvulcan.com • Website: www.cstvulcan.com<br />
Quality System Cert. No. 044 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and installation of fire sprinkler water tanks and industrial storage tanks.<br />
Wagner Group GmbH<br />
Schleswigstraße 5, D-30853 Langenhagen, Germany<br />
Tel: +49 511 97383 0 • Fax: +49 511 73338 6<br />
E-mail: info@wagner.de • Website: www.wagner.de<br />
Also at:<br />
Hanseatenstrasse 52, D-30853 Langenhagen, Germany<br />
Quality System Cert. No. 524 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, production and distribution of fire detection, fire suppression, fire prevention, risk management, intrusion monitoring and alarm<br />
systems.<br />
WOPF Befestigungselemente GmbH<br />
Luner Rennbahn 22, D-21339 Luneburg, Germany<br />
Tel: +49 4131 30110 • Fax: +49 4131 301198<br />
Website: www.wopf.de<br />
Quality System Cert. No. 918 Assessed to Factory Production Control to PN 111<br />
Scope:<br />
Development & manufacture of brackets & pipe support systems.<br />
Wrexham Mineral Cables<br />
Wynnstay Technology Park, Ruabon, Wrexham, Clwyd LL14 6EN, United Kingdom<br />
Tel: +44 (0)1978 810789 • Fax: +44 (0)1978 821502<br />
E-mail: sales@wrexhammineralcable.com • Website: www.wrexhammineralcables.com<br />
Quality System Cert. No. 333 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of mineral insulated cables and their terminations with a rated voltage not exceeding 750V.<br />
20 Nov 2011 623
PART 6: SECTION 1<br />
QUALITY SYSTEMS<br />
Writech Industrial Services Limited<br />
Also including Writech Manufacturing Limited, Mullingar Business Park, Mullingar, Co. Westmeath, Ireland<br />
Tel: +353 44 9349857 • Fax: +353 44 9349858<br />
E-mail: info@writechltd.com<br />
Quality System Cert. No. 366 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacturing, installation, commissioning and servicing of fire sprinkler systems.<br />
Xi'an System Sensor Electronics Limited<br />
28 Tuan Jie South Road, Xi'An Hi-Tech Development Zone, Xi'An, Shaan Xi 710075, China<br />
Tel: +86 29 5246253 • Fax: +86 29 5239673<br />
E-mail: xf_zhang@systemsensor.com.cn<br />
Also at:<br />
40# Zhangbar Er Road, National Xi'an Hi-Tech Industrial Development Zone, Xi'an, China<br />
Tel: +86 29 85387800 • Fax: +86 29 88332796<br />
Quality System Cert. No. 641 Assessed to ISO 9001:2008<br />
Scope:<br />
Design, manufacture and repair of fire detection and alarm system components. Manufacture of water flow alarm switches.<br />
Xtratherm Limited<br />
Kells Road, Navan, Co. Meath, Ireland<br />
Tel: +353 46 906 6000 • Fax: +353 46 906 6090<br />
E-mail: info@xtratherm.com • Website: www.xtratherm.com<br />
Quality System Cert. No. 851 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of rigid foam insulation.<br />
Xtratherm UK Limited<br />
Park Road, Holmewood Industrial Park, Holmewood, Chesterfield, Derbyshire S42 5UY, United Kingdom<br />
Tel: +44 (0)1246 858100 • Fax: +44 (0)1246 857447<br />
E-mail: info@xtratherm.com • Website: www.xtratherm.com<br />
Quality System Cert. No. 718 Assessed to ISO 9001:2008<br />
Scope:<br />
Manufacture of rigid foam insulation.<br />
Zeta Alarm Systems by GLT Exports Limited<br />
Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom<br />
Tel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176<br />
E-mail: ghassan@gltexports.com • Website: www.gltexports.com<br />
Quality System Cert. No. 330 Assessed to ISO 9001:2008<br />
Scope:<br />
Design and manufacture of fire detection and alarm systems and components.<br />
624 20 Nov 2011
PART 6: SECTION 2<br />
ENVIRONMENTAL SYSTEMS<br />
Businesses face a growing number of environmental pressures including:<br />
Energy prices<br />
Water prices<br />
Concerns from the public about pollution, climate change and resources<br />
Legislation<br />
Environmental Taxes (climate change levy, landfill tax etc)<br />
Waste disposal<br />
Environmental impact assessment<br />
Prosecution<br />
ISO 14001 is a clear way of demonstrating a company’s commitment to the ‘green’ culture, and provides an<br />
assurance to the public, regulators and purchasers that the environmental policies and procedures the<br />
company puts into place help to:-<br />
<br />
<br />
<br />
<br />
<br />
Address public concerns<br />
Reduce risk of legal non-compliance (Environmental Protection Act 1990 and a whole host of others)<br />
Reduce costs and tax burden (Climate Change Levy and rebates)<br />
Improve reputation and marketability<br />
Manage environmental performance<br />
Assessment and evaluation of environmental management systems can lead to products, systems and<br />
services that directly improve the quality of life through cleaner, safer and healthier environments.<br />
Apollo Fire Detectors Limited<br />
36 Brookside Road, Havant, Hampshire PO9 1JR, United Kingdom<br />
Tel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754<br />
E-mail: enquiries@apollo-fire.co.uk<br />
Quality System Cert. No. EMS 010 Assessed to ISO 14001:2004<br />
Scope:<br />
Design and manufacture of fire detection equipment.<br />
Hochiki Europe (UK) Limited<br />
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom<br />
Tel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132<br />
Website: www.hochikieurope.com<br />
Quality System Cert. No. EMS 164 Assessed to ISO 14001:2004<br />
Scope:<br />
Design, manufacture, service and maintenance of fire detection and alarm equipment.<br />
J W Singer<br />
Handlemaker Road, Frome, Somerset BA11 4RW, United Kingdom<br />
Tel: +44 (0)1373 462201 • Fax: +44 (0)1373 473156<br />
E-mail: enquiries@jwsinger.com • Website: www.jwsinger.com<br />
Quality System Cert. No. EMS 925 Assessed to ISO 14001:2004<br />
Scope:<br />
Manufacture of brass sprinkler heads for the fire protection industry.<br />
20 Nov 2011 625
PART 6: SECTION 2<br />
ENVIRONMENTAL SYSTEMS<br />
Kingspan Ltd<br />
Carrickmacross Road, Kingscourt, Co. Cavan, Ireland<br />
Tel: +353 42 969 8572 • Fax: +353 42 969 8576/77<br />
E-mail: info.irl@kingspanpanels.com • Website: www.kingspanpanels.com<br />
Quality System Cert. No. EMS 186 Assessed to ISO 14001:2004<br />
Scope:<br />
Design and manufacture of fire resistant wall and roof cladding materials and industrial wall and roof cladding materials, multi-beam<br />
purlins and accessories, gutters, flashing system and single and double translucent roof lights.<br />
Kingspan Ltd trading as Kingspan Structural, Kingspan Fabrications, Kingspan<br />
Controlled Environments (KCE), Kingspan Profiles and Sections<br />
Sherburn, Malton, North Yorkshire YO17 8PQ, United Kingdom<br />
Tel: +44 (0)1944 710591 • Fax: +44 (0)1944 710777<br />
E-mail: wbc@wards.co.uk • Website: www.wards.co.uk<br />
Quality System Cert. No. EMS 279 Assessed to ISO 14001:2004<br />
Scope:<br />
Design and manufacture of foam filled fire resistant insulated panels for roof, wall and cold store applications and ancillaries, cold rolled<br />
Multi-Beam, rail and channel <strong>section</strong>s, floor deck profiles; flashings, building ancillaries and architectural façade systems. Design,<br />
manufacture and installation of Kingframe building systems and cold rolled steel <strong>section</strong>s. Pre-treatment and protective coating to steel<br />
and galvanized components for architecturtal and industrial applications.<br />
Kingspan Ltd.<br />
Greenfield Business Park No. 2, Greenfield, Holywell, Flintshire CH8 7HU, United Kingdom<br />
Tel: +44 (0)1352 716100 • Fax: +44 (0)1352 716161<br />
E-mail: info@kingspanpanels.com • Website: www.kingspanpanels.com<br />
Quality System Cert. No. EMS 260 Assessed to ISO 14001:2004<br />
Scope:<br />
Manufacture of fire resistant and industrial wall and roof cladding materials.<br />
KingspanTarec Industrial Insulation Limited<br />
Glossop Brook Road, Glossop, Derbyshire SK13 8GF, United Kingdom<br />
Tel: +44 (0)870 733 0021 • Fax: +44 (0)870 700 0022<br />
E-mail: info@kingspantarec.co.uk • Website: www.kingspantarec.co.uk<br />
Quality System Cert. No. EMS 035-2 Assessed to ISO 14001:2004<br />
Scope:<br />
Manufacture of polyurethane and phenolic rigid foam insulation.<br />
Project Fire Products Limited (incorporating Project Fire Engineers)<br />
Pasturefields Lane Industrial Estate, Pasturefields Lane, Hixon, Staffordshire ST18 0PH, United Kingdom<br />
Tel: +44 (0)1889 270999 • Fax: +44 (0)1889 270974<br />
E-mail: sales@projectfire.co.uk • Website: www.projectfire.co.uk<br />
Quality System Cert. No. EMS 060 Assessed to ISO 14001<br />
Scope:<br />
Design, installation and servicing of fire sprinkler and water spray systems. Assembly, installation and commissioning, repair and<br />
servicing of water flow switch and alarm valve testing devices.<br />
626 20 Nov 2011
PART 6: SECTION 2<br />
ENVIRONMENTAL SYSTEMS<br />
Protec International Limited<br />
Construction House, Adlington Industrial Estate, Adlington, Cheshire SK10 4NL, United Kingdom<br />
Tel: +44 (0)1625 855666 • Fax: +44 (0)1625 855601<br />
E-mail: enquiries@protection.co.uk • Website: www.protection.co.uk<br />
Tel: 0800 834 704 • Fax: 0800 834 705<br />
Quality System Cert. No. EMS 843 Assessed to ISO 14001:2004<br />
Scope:<br />
The procurement and supply of specialist temporary protection materials including LPS 1207 and LPS 1215 flame retardant products for<br />
the building and construction industry.<br />
Ruskin Air Management Limited<br />
Joseph Wilson Industrial Estate, South Street, Whitstable, Kent CT5 3DU, United Kingdom<br />
Tel: +44 (0)1227 276100 • Fax: +44 (0)1227 264262<br />
E-mail: sales@actionair.co.uk • Website: www.actionair.co.uk<br />
Also at:<br />
Stourbridge Road, Bridgnorth, Shropshire WV15 5BB, United Kingdom<br />
Quality System Cert. No. EMS 017 Assessed to ISO 14001:2004<br />
Scope:<br />
Manufacture and supply of fire protection, weather protection and air distribution products.<br />
Safe Partnership<br />
3 East Street, Wareham, Dorset BH20 4NN, United Kingdom<br />
Tel: +44 (0)1929 551100 • Fax: +44 (0)1929 553300<br />
E-mail: safe@safe<strong>part</strong>nership.org • Website: www.safe<strong>part</strong>nership.co.uk<br />
Quality System Cert. No. EMS 835 Assessed to ISO 14001<br />
Scope:<br />
Manufacture, supply, installation and repair of timber doors. Supply installation, maintenance and repair of domestic physical security<br />
products.<br />
SPP Pumps Limited<br />
Theale Cross, Pincents Lane, Calcot, Reading, Berkshire RG31 7SP, United Kingdom<br />
Tel: +44 (0)118 932 3123 • Fax: +44 (0)118 932 3302<br />
E-mail: solutions@spppumps.com • Website: www.spppumps.com<br />
Quality System Cert. No. EMS 111 Assessed to ISO 14001:2004<br />
Scope:<br />
Design, manufacture and supply of pumps, pump packages and generator sets for use in construction, building services, oil and gas and<br />
water industries as well as general industry. Project management and the assembly of pump packages and generators including<br />
associated documentation. Service and provision of spare <strong>part</strong>s, repair and maintenance of pumps, valves, compressors and other allied<br />
equipment.<br />
Sites covered by this Approval:<br />
Sales & Service Centre: Theale Cross, Pincents Lane, Calcot, Reading, Berkshire RG31 7SP UK<br />
Design & Manufacture : Crucible Close, Muschet Industrial Park, Coleford, Gloucestershire GL16 8PS UK<br />
Service Centre: Tufthorn Avenue, Coleford, Gloucestershire GL16 8PJ UK<br />
Service Centre: Unit 2, Oak Bank, Channel Commercial Park, Belfast, Northern Ireland BT3 9DT<br />
20 Nov 2011 627
PART 6: SECTION 2<br />
ENVIRONMENTAL SYSTEMS<br />
Service Centre: Unit 1, Stanstead Road, Eastleigh, Hampshire SO50 4RZ UK<br />
Service Centre: Greg Street, Reddish, Stockport, Cheshire SK5 7BU UK<br />
Technocover Limited (incorporating TechnoRail and Strataform)<br />
Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom<br />
Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527<br />
E-mail: techadvice@technocover.co.uk • Website: www.technocover.co.uk<br />
Quality System Cert. No. EMS 450 Assessed to ISO 14001:2004<br />
Scope:<br />
The design, manufacture and installation of metal security covers, doors, grating and staging.<br />
Tyco Fire Products Manufacturing Limited<br />
Stockport Trading Estate, Yew Street, Stockport, Cheshire SK4 2JW, United Kingdom<br />
Tel: +44 (0)161 429 3400 • Fax: +44 (0)161 477 6729<br />
E-mail: tycofireproducts.uk@tyco-bspd.com • Website: www.tycobuilding.com<br />
Quality System Cert. No. EMS 007 Assessed to ISO 14001:2004<br />
Scope:<br />
Design and manufacture of fire protection valves, fire sprinklers, high and medium velocity nozzles and controls.<br />
Xtratherm UK Limited<br />
Park Road, Holmewood Industrial Park, Holmewood, Chesterfield, Derbyshire S42 5UY, United Kingdom<br />
Tel: +44 (0)1246 858100 • Fax: +44 (0)1246 857447<br />
E-mail: info@xtratherm.com • Website: www.xtratherm.com<br />
Quality System Cert. No. EMS 718 Assessed to ISO 14001:2004<br />
Scope:<br />
Manufacture of rigid foam insulation.<br />
628 20 Nov 2011
PART 6: SECTION 3<br />
HEALTH & SAFETY CERTIFICATION BS OHSAS 18001<br />
HSE statistics show that some thirty million working days were lost due to work related health and safety<br />
issues In the UK in 2006/07.<br />
Poor health and safety performance not only means loss of revenue, but also loss of reputation, license to<br />
trade and business, and huge extra costs. In some instances it can lead to very large fines or custodial<br />
sentences. Good health and safety performance reduces costs and gives companies a competitive edge.<br />
BS OHSAS 18001 is a specification that helps to fully integrate health and safety into company policies and<br />
working practices. This in turn helps the company to identify risks, engage staff and continuously improve<br />
processes and systems. It also signals to architects, clients, insurers and specifiers that the company takes its<br />
health and safety responsibilities seriously.<br />
The assessment standard for this scheme is:<br />
BS OHSAS 18001:2007 Occupational health and safety management systems - Requirements.<br />
Argus Fire Protection Company Limited<br />
Hendglade House, 46 New Road, Stourbridge, West Midlands DY8 1PA, United Kingdom<br />
Tel: +44 (0)1384 376256 • Fax: +44 (0)1384 393955<br />
E-mail: info@argusfire.co.uk • Website: www.argusfire.co.uk<br />
Quality System Cert. No. 011-HS Assessed to OHSAS 18001:2007<br />
Scope:<br />
Design, supply and installation, servicing and maintenance of fire protection and detection systems, including site based activities.<br />
Kingspan Ltd<br />
Carrickmacross Road, Kingscourt, Co. Cavan, Ireland<br />
Tel: +353 42 969 8572 • Fax: +353 42 969 8576/77<br />
E-mail: info.irl@kingspanpanels.com • Website: www.kingspanpanels.com<br />
Quality System Cert. No. 186-HS Assessed to OHSAS 18001:2007<br />
Scope:<br />
Design and manufacture of fire resistant wall and roof cladding materials and industrial wall and roof cladding materials, multi-beam<br />
purlins and accessories, gutters, flashing system and single and double translucent roof lights.<br />
Kingspan Ltd trading as Kingspan Structural, Kingspan Fabrications, Kingspan<br />
Controlled Environments (KCE), Kingspan Profiles and Sections<br />
Sherburn, Malton, North Yorkshire YO17 8PQ, United Kingdom<br />
Tel: +44 (0)1944 710591 • Fax: +44 (0)1944 710777<br />
E-mail: wbc@wards.co.uk • Website: www.wards.co.uk<br />
Quality System Cert. No. 279-HS Assessed to OHSAS 18001:2007<br />
Scope:<br />
Design and manufacture of foam filled fire resistant insulated panels for roof, wall and cold store applications and ancillaries, cold rolled<br />
Multi-Beam, rail and channel <strong>section</strong>s, floor deck profiles; flashings, building ancillaries and architectural façade systems. Design,<br />
manufacture and installation of Kingframe building systems and cold rolled steel <strong>section</strong>s. Pre-treatment and protective coating to steel<br />
and galvanized components for architecturtal and industrial applications.<br />
20 Nov 2011 629
PART 6: SECTION 3<br />
HEALTH & SAFETY CERTIFICATION BS OHSAS 18001<br />
Kingspan Ltd.<br />
Greenfield Business Park No. 2, Greenfield, Holywell, Flintshire CH8 7HU, United Kingdom<br />
Tel: +44 (0)1352 716100 • Fax: +44 (0)1352 716161<br />
E-mail: info@kingspanpanels.com • Website: www.kingspanpanels.com<br />
Quality System Cert. No. 260-HS Assessed to OHSAS 18001:2007<br />
Scope:<br />
Manufacture of fire resistant and industrial wall and roof cladding materials.<br />
Xtratherm UK Limited<br />
Park Road, Holmewood Industrial Park, Holmewood, Chesterfield, Derbyshire S42 5UY, United Kingdom<br />
Tel: +44 (0)1246 858100 • Fax: +44 (0)1246 857447<br />
E-mail: info@xtratherm.com • Website: www.xtratherm.com<br />
Quality System Cert. No. 718-HS Assessed to OHSAS 18001:2007<br />
Scope:<br />
Manufacture of rigid foam insulation.<br />
630 20 Nov 2011