<strong>TCA</strong><br />

Conical Ceiling Diffuser<br />

20/<strong>TCA</strong>/3500/0106/EN<br />

• Horizontal or vertical air supply, suitable also for<br />

heating applications<br />

• Installation flush to the ceiling, or exposed<br />

especially in high spaces<br />

• Circular duct connection with rubber gasket<br />

• Openable cone module enables cleaning of the<br />

diffuser and ductwork<br />

Product Models & Accessories<br />

• Models integrated in a panel for installation in<br />

modular 600 x 600 mm suspended ceilings<br />

• Balancing plenum with adjustment functions or with<br />

measurement function (TRI, PLC)<br />

• Actuator (24 VAC with 0…10 VDC control signal or<br />

wax-bulb) for the direction of airflow pattern<br />

MATERIAL AND FINISHING<br />

PART MATERIAL FINISHING<br />

Diffuser Hard-rolled steel Epoxy-painted / White RAL 9010 or Grey RAL 7004, 50% gloss<br />

Plenum<br />

Galvanised steel<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

130


QUICK SELECTION<br />

Pa 360 480 720 960 1320 1800 2400 3600 4800 6360 8400 10800 14400 21600 36000<br />

qv l/s 30 40 60 80 110 150 200 300 400 530 700 900 1200 1800 3000<br />

m 3 /h 108 144 216 288 396 540 720 1080 1440 1908 2520 3240 4320 6480 10800<br />

<strong>TCA</strong>-125(R) LpA 19 27 38 46<br />

DPst 3 5 12 22<br />

DPtot 7 12 27 47<br />

Ld - - - -<br />

Lmin - 0,5 1,2 2,0<br />

L0.2 1,8 2,4 3,8 5,0<br />

<strong>TCA</strong>-160(R) LpA 25 34 44 54<br />

DPst 9 15 29 54<br />

DPtot 14 25 47 87<br />

Ld - - 4,4 5,4<br />

Lmin 0,5 1,0 1,7 2,7<br />

L0.2 2,4 3,2 4,6 6,2<br />

<strong>TCA</strong>-200(R) LpA 24 32 41 48<br />

DPst 8 15 28 51<br />

DPtot 12 23 42 75<br />

Ld - - 4,0 4,8<br />

Lmin 0,5 0,8 1,5 2,3<br />

L0.2 2,2 3,0 4,2 5,6<br />

<strong>TCA</strong>-250(R) LpA 24 30 37 48<br />

DPst 4 7 12 27<br />

DPtot 7 12 22 49<br />

Ld - 3,2 3,8 4,8<br />

Lmin 0,5 1,0 1,7 3,0<br />

L0.2 2,4 3,4 4,4 6,8<br />

<strong>TCA</strong>-315(R) LpA 25 38 47<br />

DPst 5 11 20<br />

DPtot 9 20 36<br />

Ld 2,8 3,6 4,2<br />

Lmin 1,1 2,1 3,1<br />

L0.2 3,4 5,2 7,0<br />

<strong>TCA</strong>-355(R) LpA 20 31 38 45<br />

DPst 3 8 13 24<br />

DPtot 6 13 23 41<br />

Ld 2,6 3,4 4,2 4,8<br />

Lmin 1,0 2,0 2,9 4,2<br />

L0.2 3,2 5,0 6,6 8,8<br />

<strong>TCA</strong>-400(R) LpA 28 35 42 49<br />

DPst 4 8 14 24<br />

DPtot 8 14 24 42<br />

Ld 3,0 3,6 4,4 5,2<br />

Lmin 1,6 2,5 3,6 5,1<br />

L0.2 4,4 5,8 7,8 10,2<br />

<strong>TCA</strong>-450(R) LpA 27 35 43 50<br />

DPst 4 8 13 22<br />

DPtot 8 14 25 41<br />

Ld 3,0 3,6 4,4 5,0<br />

Lmin 1,7 2,6 3,8 5,1<br />

L0.2 4,6 6,0 8,0 10,2<br />

<strong>TCA</strong>-500(R) LpA 22 30 38 47<br />

DPst 3 5 8 14<br />

DPtot 7 13 21 37<br />

Ld 3,4 3,8 4,4 5,2<br />

Lmin 2,1 3,1 4,3 6,1<br />

L0.2 5,2 7,0 8,8 11,8<br />

20/<strong>TCA</strong>/3500/0106/EN<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

131


QUICK SELECTION<br />

Pa 360 480 720 960 1320 1800 2400 3600 4800 6360 8400 10800 14400 21600 36000<br />

qv l/s 30 40 60 80 110 150 200 300 400 530 700 900 1200 1800 3000<br />

m 3 /h 108 144 216 288 396 540 720 1080 1440 1908 2520 3240 4320 6480 10800<br />

20/<strong>TCA</strong>/3500/0106/EN<br />

<strong>TCA</strong>-560(R) LpA 27 35 43 56<br />

DPst 5 8 14 32<br />

DPtot 10 16 29 64<br />

Ld 3,4 4,0 4,6 5,8<br />

Lmin 5,2 7,2 10,2 16,4<br />

L0.2 6,0 7,6 10,2 15,0<br />

<strong>TCA</strong>-630(R) LpA 29 37 50<br />

DPst 7 12 28<br />

DPtot 12 21 48<br />

Ld 3,4 4,0 5,0<br />

Lmin 6,0 8,6 13,8<br />

L0.2 6,6 8,8 13,0<br />

<strong>TCA</strong>-800(R) LpA 26 38 54<br />

DPst 4 9 25<br />

DPtot 7 17 47<br />

Ld 3,2 4,0 5,2<br />

Lmin 5,8 9,8 17,6<br />

L0.2 6,6 9,8 16,0<br />

<strong>TCA</strong>-1000(R) LpA 26 42<br />

DPst 5 15<br />

DPtot 8 24<br />

Ld 3,4 4,6<br />

Lmin 8,2 15,0<br />

L0.2 8,4 14,0<br />

LpA values presented with room attenuation 4 dB (red 10m 2 -<br />

sab). When using room attenuation 8 dB (red 25m 2 - sab):<br />

LpA - 4dB.<br />

Pa<br />

LpA<br />

DPst<br />

Supply air cooling capacity, W<br />

A-weighted sound pressure level, reduced by total<br />

equivalent absorption surface of 10m 2 , dB(A) red<br />

0m 2 - sab<br />

Static pressure drop, Pa<br />

DPtot<br />

Ld<br />

Lmin<br />

L0.<br />

Total pressure drop, Pa<br />

Distance from the supply unit, at which air jet<br />

detaches from ceiling, m<br />

Minimum distance between central lines of two<br />

supply units, m (V3 = 0,25m/s at 1.8m height)<br />

Isotermal throw length, m when residual velocity of<br />

supply air jet 0,2 m/s<br />

Room temperature (Tr) = 24 °C<br />

Supply air temperature (Ta) = 14 °C<br />

Room height<br />

= 2,8 m<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

132


Product Models<br />

Sizes 125, 160, 200 and 250 are available integrated in<br />

a steel panel for installation in modular 600x600 mm<br />

suspended ceilings.<br />

The external dimensions of the front panel are<br />

595 mm x 595 mm.<br />

20/<strong>TCA</strong>/3500/0106/EN<br />

ACCESSORIES<br />

ACCESSORY CODE DESCRIPTION<br />

Balancing plenum with airflow<br />

measurement and adjustment unit<br />

TRI/N<br />

For balancing, equalizing the airflow<br />

Plenum PLC Plenum for duct connection (with or without insulation)<br />

Sound attenuation IN Polyester fiber as sound attenuation material in the TRI plenum. Mineral wool as<br />

sound attenuation material in the PLC.<br />

Airflow measurement and<br />

adjustment unit<br />

MSM<br />

For supply installation<br />

Airflow adjustment unit LD Circular galvanised steel unit for flow adjustment (inside the coupling sleeve)<br />

Airflow adjustment damper DC Circular galvanised steel blade damper for flow adjustment (inside the coupling<br />

sleeve)<br />

Airflow adjustment unit CU1 Circular galvanised steel unit for flow adjustment in the plenum<br />

Electrical actuator M1 Adjustment of the position of the conical central core<br />

Wax-bulb actuator M2 Adjustment of the position of the conical central core<br />

Wax-bulb actuator<br />

The <strong>TCA</strong> (D355…630mm) can be equipped with a waxbulb<br />

actuator. Neither auxiliary energy nor dedicated<br />

control system are needed.<br />

The actuator position changes according to the<br />

temperature of supply air.<br />

When warm air is supplied at a temperature up<br />

to 18°C, the wax bulb actuator piston moves<br />

progressively until the conical central core is at the<br />

low position. The supply air pattern is vertical compact<br />

jet.<br />

The cycle for movement between extreme positions<br />

takes 10 to 20 minutes.<br />

When cold air is supplied, the conical central cone<br />

is returned back by springs to the upper position for<br />

horizontal radial jet function.<br />

The operation range of the wax-bulb actuator is<br />

between 18°C and 32°C.<br />

No maintenance is required for the wax-bulb actuator.<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

133


20/<strong>TCA</strong>/3500/0106/EN<br />

Compact jet<br />

Radial Jet<br />

Function<br />

Supply air is supplied into the space through cones,<br />

either horizontally along the ceiling (ventilation or<br />

cooling application) or vertically (heating application).<br />

The supply air mixes with the room air around the<br />

diffuser.<br />

The adjustment from the radial jet position to the<br />

compact jet position can be performed either manually<br />

or by using an electric or wax-bulb actuator.<br />

DIMENSIONS<br />

NS ØW H H1 H2 ØD<br />

125 286 137 100 7 124<br />

160 343 142 100 9 159<br />

200 457 162 100 9 199<br />

250 572 178 100 15 248<br />

315 686 190 100 18 314<br />

355 857 233 115 20 354<br />

400 857 252 141 20 399<br />

450 1029 300 160 22 449<br />

500 1029 281 22 499<br />

560 1175 348 181 17 558<br />

630 1175 350 196 17 628<br />

800 1727 427 180 25 797<br />

1000 1727 373 180 25 997<br />

H<br />

H1<br />

ØD<br />

H3 ØW<br />

Actuator model Manual M1 M2<br />

H2<br />

NS H3 H3 H3<br />

125 130<br />

160 133<br />

200 153<br />

250 163 563<br />

315 172 572<br />

355 213 588 213<br />

400 232 582 232<br />

450 278 618 278<br />

500 259 599 259<br />

560 331 641 331<br />

630 333 628 333<br />

800 402 722<br />

1000 348 668<br />

M1 = Electric actuator 0-10 VDC<br />

M2 = Wax-bulb actuator<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

134


20/<strong>TCA</strong>/3500/0106/EN<br />

Installation<br />

CODE DESCRIPTION<br />

1 Conical central core<br />

2 External cone<br />

The <strong>TCA</strong> diffuser can be installed flush with a<br />

suspended ceiling or fully exposed in the space.<br />

The diffuser is connected either directly to the duct or<br />

using a PLC plenum or TRI balancing plenum.<br />

When connected directly to ductwork a safety<br />

distance of minimum 3xD upstream of the diffuser<br />

should be maintained.<br />

Installation with plenum PLC<br />

ØD1<br />

ØD<br />

H3<br />

ØW1<br />

H1<br />

<strong>TCA</strong> (ØD) ØD1 PLC H1 H3<br />

125 125 PLC125 7 336-366<br />

160 160 PLC160 9 336-366<br />

200 200 PLC200 9 444-474<br />

250 250 PLC 250 15 457-487<br />

315 315 PLC 315 18 616-646<br />

355 355 PLC 355 20 760-790<br />

400 400 PLC 400 20 710-740<br />

450 450 PLC 450 22 927-957<br />

560 560 PLC 560 17 1024-1054<br />

630 630 PLC 630 17 1040-1070<br />

Installation with plenum TRI<br />

<strong>TCA</strong> ØD1 TRI H1 H3<br />

125 125 TRI125/125 7 329-359<br />

160 160 TRI160/160 9 372-402<br />

200 200 TRI200/200 9 442-472<br />

250 250 TRI250/250 15 516-546<br />

315 315 TRI315/315 18 571-601<br />

Dimensions of the ceiling opening<br />

<strong>TCA</strong><br />

ØW1<br />

125 260<br />

160 318<br />

200 432<br />

250 533<br />

315 635<br />

355 787<br />

400 787<br />

450 940<br />

500 940<br />

560 1130<br />

630 1130<br />

800 1670<br />

1000 1670<br />

The technical performance for the combination of<br />

supply air diffuser and TRI plenum is presented<br />

separately for the two different installations. See HIT<br />

Design software.<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

135


20/<strong>TCA</strong>/3500/0106/EN<br />

Adjustment<br />

CODE DESCRIPTION<br />

1 plenum box plc<br />

2 Measurement and adjustment<br />

Part (MSM)<br />

The airflow rate can be adjusted and measured only<br />

when the diffuser is installed.<br />

In order to enable airflow adjustment and<br />

measurement of the airflow rate, it is recommended<br />

that the diffuser be connected to the plenum<br />

equipped with the MSM module.<br />

The supply flow rate is determined by using the<br />

measurement and adjustment module MSM.<br />

Unscrew the conical central core and pass the tubes<br />

and control spindle through the diffuser.<br />

Measure the differential pressure using a manometer.<br />

The flow rate is calculated using the formula below.<br />

q<br />

v<br />

= k *<br />

p<br />

m<br />

Adjust the airflow rate by rotating the control spindle<br />

until the desired setting is achieved.<br />

Lock the damper position with a screw.<br />

Replace the tubes and spindle into the plenum and<br />

replace the central cone.<br />

K factor for installations with different safety distances<br />

(D= duct diameter)<br />

Airflow adjustment damper DC<br />

The airflow rate is adjusted by turning the damper<br />

blades behind the diffuser with a screwdriver. The<br />

measurement is carried out when diffuser is installed.<br />

PLC/TRI >8XD min 3XD<br />

100 6.0 7.5<br />

125 9.9 12.6<br />

160 16.9 21.9<br />

200 28.3 31.0<br />

250 47.9 51.5<br />

315 78.6 -<br />

Servicing<br />

Remove the conical central core by gently drawing it<br />

out by the central core.<br />

Clean the parts by wiping them with a damp cloth.<br />

Push the conical central core back into place so that<br />

the springs lock.<br />

Option: with balancing plenum TRI + MSM or PLC<br />

+ MSM<br />

Remove the measurement and adjustment module by<br />

gently pulling the shaft (not the control spindle).<br />

Wipe the parts with a damp cloth, instead of<br />

immersing in water.<br />

Reassemble the measurement and adjustment<br />

module by pushing the shaft back into place until the<br />

module meets the stopper.<br />

Push the diffuser back into place so that the springs<br />

lock.<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

136


Pressure drop, throw pattern and sound data<br />

Supply, horizontal jet<br />

20/<strong>TCA</strong>/3500/0106/EN<br />

<strong>TCA</strong> 125, <strong>TCA</strong> 160, <strong>TCA</strong> 200<br />

<strong>TCA</strong> 250, <strong>TCA</strong> 315, <strong>TCA</strong> 355, <strong>TCA</strong> 400<br />

<strong>TCA</strong> 450, <strong>TCA</strong> 560, <strong>TCA</strong> 630 <strong>TCA</strong> 800, <strong>TCA</strong> 1000<br />

Selection example :<br />

Requirements : qv = 1000 l/s Selection : <strong>TCA</strong>-630<br />

LpA < 35 dB(A)<br />

LpA < 32 dB(A)<br />

L0,2 < 10,0 m L0,2 < 9,0 m<br />

Horizontal jet<br />

DPtot = 15 Pa<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

137


Pressure drop, throw pattern and sound data<br />

Supply, vertical jet<br />

20/<strong>TCA</strong>/3500/0106/EN<br />

<strong>TCA</strong> 125, <strong>TCA</strong> 160, <strong>TCA</strong> 200, <strong>TCA</strong> 250<br />

<strong>TCA</strong> 315, <strong>TCA</strong> 355, <strong>TCA</strong> 400<br />

<strong>TCA</strong> 450, <strong>TCA</strong> 560, <strong>TCA</strong> 630 <strong>TCA</strong> 800, <strong>TCA</strong> 1000<br />

Selection example :<br />

Requirements : qv = 500 l/s Selection : <strong>TCA</strong>-450<br />

LpA < 35 dB(A)<br />

LpA < 33 dB(A)<br />

0,2 2<br />

< 25 m L0,2 < 22 m<br />

DT = 0 °C<br />

DPtot = 13 Pa<br />

Vertical jet<br />

Note :<br />

For supply of non isothermal air, please see next page.<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

138


Vertical throw pattern with non-isothermal air<br />

Vertical throw patterns shown in the diagrams are<br />

based on isothermal air. When heated or chilled jets<br />

are considered, the distance of projection changes<br />

due to air density.<br />

Throw patterns using different input data can be seen<br />

calculated precisely using the <strong>Halton</strong> HIT Design, or<br />

the table below to determine the projection factor.<br />

Multiply the factor by the isothermal throw pattern<br />

(L0.2) to determine estimated projection distance:<br />

20/<strong>TCA</strong>/3500/0106/EN<br />

DT (°C) ±0 ±5 ±8 ±10 ±12 ±14 ±16<br />

K cooling 1,00 1,30 1,40 1,45 1,50 1,52 1,55<br />

K heating 1,00 0,27 0,23 0,21 0,20 0,19 0,18<br />

Selection example :<br />

Requirements : qv = 500 l/s Selection : <strong>TCA</strong>-450<br />

LpA < 35 dB(A)<br />

LpA = 36 dB(A)<br />

L0.2 < 25m L0.2 = 22 m x 0.20 = 4,4 m<br />

DT = +12 °C<br />

DPtot = 13 Pa<br />

Vertical jet<br />

SOUND LEVEL DATA, HORIZONTAL JET<br />

qv DPst DPtot F (Hz) LpA NR NC<br />

(l/s) (m 3 /h) (Pa) (Pa) 125 250 500 1000 2000 4000 [dB(A)]<br />

<strong>TCA</strong>-125(R) 38 137 5 10 29 32 28 24 14 6 25 20 18<br />

45 162 7 15 34 37 33 29 20 13 30 25 23<br />

54 194 10 21 39 41 38 34 27 20 35 30 28<br />

64 230 14 31 44 46 43 39 33 27 40 35 34<br />

<strong>TCA</strong>-160(R) 60 216 9 14 28 31 28 22 20 4 25 20 18<br />

70 252 12 19 34 36 33 28 26 10 30 25 23<br />

82 295 16 26 39 40 38 33 31 17 35 30 28<br />

96 346 22 36 44 44 43 38 36 24 40 35 34<br />

<strong>TCA</strong>-200(R) 83 299 9 13 36 33 26 21 20 16 25 19 16<br />

101 364 13 19 41 38 31 26 25 20 30 24 21<br />

121 436 18 27 45 43 36 31 30 24 35 29 26<br />

147 529 27 40 50 48 41 36 35 28 40 34 32<br />

<strong>TCA</strong>-250(R) 118 425 4 8 31 27 24 14 26 4 25 25 23<br />

148 533 7 12 38 33 31 22 30 11 30 29 27<br />

182 655 10 18 44 39 37 29 34 18 35 33 30<br />

221 796 15 27 49 44 42 36 37 24 40 36 34<br />

<strong>TCA</strong>-315(R) 198 713 5 9 32 32 26 25 11 10 25 21 19<br />

233 839 7 12 38 37 32 30 17 15 30 26 24<br />

274 986 9 17 43 41 37 35 23 20 35 31 29<br />

322 1159 13 23 49 46 42 40 29 25 40 36 34<br />

<strong>TCA</strong>-355(R) 240 864 5 8 36 34 26 20 14 9 25 19 16<br />

293 1055 7 12 42 38 32 26 20 15 30 24 22<br />

355 1278 11 18 47 43 37 31 25 20 35 29 27<br />

433 1559 16 27 52 48 42 36 30 26 40 34 33<br />

<strong>TCA</strong>-400(R) 265 954 3 6 37 33 26 21 15 9 25 19 16<br />

323 1163 5 9 42 38 31 26 20 15 30 24 21<br />

394 1418 8 13 47 43 36 31 25 20 35 29 27<br />

482 1735 11 20 52 48 42 36 31 26 40 34 33<br />

<strong>TCA</strong>-450(R) 363 1307 4 7 35 36 22 18 14 12 25 21 18<br />

441 1588 5 10 40 40 28 24 21 18 30 26 24<br />

534 1922 8 14 45 45 34 30 27 24 35 31 29<br />

637 2293 11 20 50 49 40 36 33 30 40 35 33<br />

<strong>TCA</strong>-560(R) 648 2333 4 8 24 26 28 23 21 13 25 20 17<br />

766 2758 6 12 29 31 33 28 26 18 30 25 23<br />

902 3247 8 16 34 36 38 33 31 23 35 30 29<br />

1062 3823 12 23 39 41 43 38 36 28 40 35 34<br />

<strong>TCA</strong>-630(R) 792 2851 5 9 24 26 28 24 21 13 25 20 18<br />

933 3359 7 13 29 31 33 29 26 18 30 25 23<br />

1101 3964 10 18 34 36 38 34 31 23 35 30 28<br />

1302 4687 15 25 39 41 43 39 36 28 40 35 34<br />

<strong>TCA</strong>-800(R) 1169 4208 4 7 24 26 28 24 21 10 25 20 18<br />

1382 4975 5 10 29 31 33 29 26 12 30 25 24<br />

1630 5868 7 14 34 36 38 34 31 15 35 30 29<br />

1927 6937 10 19 39 41 43 39 36 18 40 36 34<br />

<strong>TCA</strong>-1000(R) 1774 6386 5 8 24 26 28 24 21 13 25 20 18<br />

2073 7463 7 11 29 31 33 29 26 18 30 25 23<br />

2411 8680 9 15 34 36 38 34 31 23 35 30 29<br />

2802 10087 13 20 39 41 43 39 36 28 40 35 34<br />

LpA values presented with room attenuation 4 dB (red 10m 2 - sab). When using room attenuation 8 dB (red 25m 2 - sab): LpA - 4dB.<br />

NR/NC noise criteria<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

139


SOUND LEVEL DATA, VERTICAL JET<br />

qv DPst DPtot F (Hz) LpA NR NC<br />

(l/s) (m 3 /h) (Pa) (Pa) 125 250 500 1000 2000 4000 [dB(A)]<br />

<strong>TCA</strong>-125(C) 34 122 5 9 29 32 30 21 12 3 25 22 20<br />

40 144 6 13 34 36 35 26 18 9 30 27 25<br />

48 173 9 19 39 41 40 31 25 16 35 32 31<br />

58 209 13 26 44 45 45 36 32 23 40 37 36<br />

<strong>TCA</strong>-160(C) 54 194 8 12 28 31 30 19 19 3 25 21 20<br />

63 227 11 17 33 35 35 24 24 7 30 27 25<br />

74 266 15 24 39 39 40 30 30 13 35 32 30<br />

87 313 21 32 44 44 45 35 35 20 40 37 36<br />

<strong>TCA</strong>-200(C) 76 274 8 12 37 32 28 18 19 13 25 19 18<br />

91 328 12 17 41 37 33 23 24 18 30 25 23<br />

110 396 18 25 46 42 38 28 29 22 35 30 29<br />

133 479 26 36 50 47 43 33 34 26 40 35 34<br />

<strong>TCA</strong>-250(C) 104 374 4 6 31 25 26 10 26 3 25 25 22<br />

131 472 6 10 37 32 32 18 30 8 30 29 26<br />

161 580 9 16 43 37 38 25 34 14 35 33 30<br />

197 709 14 23 49 43 44 32 37 21 40 36 35<br />

<strong>TCA</strong>-315(C) 184 662 5 8 32 32 29 22 10 7 25 21 19<br />

215 774 7 11 38 36 34 27 16 12 30 26 24<br />

252 907 9 16 43 41 39 32 22 17 35 31 30<br />

295 1062 13 21 49 45 44 37 27 22 40 36 35<br />

<strong>TCA</strong>-355(C) 213 767 4 7 36 33 28 17 13 6 25 20 18<br />

261 940 7 11 42 38 34 23 19 12 30 26 24<br />

317 1141 10 16 47 42 39 28 24 17 35 31 30<br />

385 1386 14 23 52 47 44 33 29 23 40 36 35<br />

<strong>TCA</strong>-400(C) 236 850 3 5 37 33 28 18 14 6 25 20 18<br />

289 1040 5 8 42 38 33 23 19 12 30 25 23<br />

353 1271 7 12 47 42 38 28 24 17 35 30 29<br />

429 1544 10 17 52 47 44 33 30 23 40 36 35<br />

<strong>TCA</strong>-450(C) 334 1202 3 6 36 36 24 15 13 9 25 21 18<br />

404 1454 5 9 41 40 30 21 19 15 30 26 23<br />

485 1746 7 13 46 44 36 27 26 21 35 31 28<br />

582 2095 11 19 51 49 42 33 32 27 40 35 33<br />

<strong>TCA</strong>-560(C) 589 2120 4 8 24 25 30 20 20 10 25 22 20<br />

693 2495 6 10 29 30 35 25 25 15 30 27 25<br />

819 2948 8 14 34 35 40 30 30 20 35 32 31<br />

969 3488 11 20 39 40 45 35 35 25 40 37 36<br />

<strong>TCA</strong>-630(C) 721 2596 5 8 24 24 30 21 20 10 25 22 20<br />

849 3056 7 12 29 29 35 26 25 15 30 27 25<br />

998 3593 10 16 34 35 40 31 30 20 35 32 31<br />

1172 4219 14 22 39 40 45 36 35 25 40 37 36<br />

<strong>TCA</strong>-800(C) 1059 3812 4 6 24 25 30 21 20 8 25 22 20<br />

1249 4496 5 9 29 30 35 26 25 11 30 27 26<br />

1469 5288 7 12 34 35 40 31 30 13 35 32 31<br />

1736 6250 10 17 39 40 45 36 35 16 40 37 36<br />

<strong>TCA</strong>-1000(C) 1627 5857 5 8 24 25 30 21 20 10 25 22 20<br />

1885 6786 7 10 29 30 35 26 25 15 30 27 25<br />

2202 7927 9 14 34 35 40 31 30 20 35 32 31<br />

2560 9216 12 19 39 40 45 36 35 25 40 37 36<br />

LpA values presented with room attenuation 4 dB (red 10m 2 - sab). When using room attenuation 8 dB (red 25m 2 - sab): LpA - 4dB.<br />

NR/NC noise criteria<br />

20/<strong>TCA</strong>/3500/0106/EN<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

140


Suggested Specifications<br />

The diffuser shall be made of four cones made of<br />

epoxy-painted steel with a white (RAL 9010) or grey<br />

(RAL 7004) colour.<br />

The diffuser shall be suitable for installation on<br />

exposed ductwork or flush to the ceiling.<br />

Product Code<br />

<strong>TCA</strong>/S-D-W(J)<br />

S = Model<br />

A<br />

B<br />

Standard<br />

Suspended ceiling installation<br />

600 x 600 mm<br />

20/<strong>TCA</strong>/3500/0106/EN<br />

The diffuser shall be connected to the ductwork using<br />

a TRI balancing plenum, which comprises polyester<br />

fibre with a washable surface as sound attenuation<br />

material.<br />

D = Diameter of duct connection<br />

S=A: 125, 160, 200, 250, 315, 355, 400, 450,<br />

500, 560, 630, 800, 1000<br />

S=B: 125, 160, 200, 250<br />

Option<br />

The diffuser shall be connected to the ductwork using<br />

a PLC plenum with mineral wool as sound attenuation<br />

material.<br />

W = Width<br />

S=B: 600<br />

Specifics and accessories<br />

The plenum shall comprise an airflow measurement<br />

and adjustment module.<br />

The diffuser shall be suitable for installation into<br />

600x600 suspended ceilings.<br />

The airflow flow pattern shall be adjustable from<br />

horizontal to vertical by turning the inner cones.<br />

Option<br />

Where both heating and cooling are required, the air<br />

pattern can be changed automatically via an electric or<br />

wax-bulb actuator.<br />

CO = Colour<br />

W White<br />

G Grey<br />

MO = Actuator type<br />

N Not assigned<br />

M1 Electric actuator<br />

M2 Wax-bulb actuator<br />

Code example<br />

<strong>TCA</strong>/A-125(C), CO=W,MO=N<br />

Sub products<br />

PLC<br />

TRI<br />

Plenum (Ceiling diffusers)<br />

Plenum (Diffusers)<br />

<strong>TCA</strong> - Conical Ceiling Diffuser<br />

141

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!