MANUFACTURED HOUSING UNIT<br />

PERMIT REQUIREMENTS<br />

FOR<br />

APACHE COUNTY<br />

When applying <strong>for</strong> a <strong>manufactured</strong> home <strong>permit</strong>, this department must have the<br />

following items prior to the <strong>permit</strong> being issued:<br />

1. A copy of the septic <strong>permit</strong> from the County Health Department or a letter from the applicable<br />

sanitary district.<br />

2. A plot plan showing: a. the location of all existing buildings or structures.<br />

b. proposed building(s). c. proper setbacks.<br />

3. A map showing the location of the property.<br />

4. Total Valuation of <strong>manufactured</strong> home, not including land.<br />

NOTE: IF THE PROPERTY WAS ACQUIRED WITHIN ONE-HUNDRED TWENTY (120) DAYS PRIOR<br />

TO APPLICATION FOR THE PERMIT, A COPY OF THE RECORDED DEED OR SALES<br />

TRANSACTION IS REQUIRED.<br />

Application fee <strong>for</strong> the <strong>permit</strong> is $245.00. Make checks payable to the Apache County Building Department.<br />

Put your <strong>permit</strong> number on the bottom of your check.<br />

Request <strong>for</strong> inspection must be made at least 24 hours prior to inspection. MUST BE COMPLETELY<br />

SET-UP AND HOOKED TO ALL UTILITIES BEFORE INSPECTION IS REQUESTED.<br />

NOTE: ELECTRICAL WILL NOT BE GREEN TAGGED UNTIL ALL OTHER ITEMS HAVE BEEN<br />

INSPECTED AND PASSED. ALSO, DO NOT PUT SKIRTING ON MANUFACTURED HOME UNTIL<br />

THE UNIT HAS PASSED FINAL INSPECTION.<br />

Installation and inspection in<strong>for</strong>mation is included in this packet.<br />

APACHE COUNTY BUILDING DEPARTMENT<br />

PO Box 238 75 West Cleveland<br />

St. Johns, Arizona 85936<br />

Phone: 520-337-7527<br />

Fax: 520-337-2062<br />

MOBILE HOME INSPECTION REQUIREMENTS


1. SET UP: Piers at proper intervals<br />

Treated plate and/or wedges (wood)<br />

OR<br />

Jacks at proper intervals<br />

Correct size pads under Jacks<br />

2. WATER: Proper Depth <strong>for</strong> freeze protection. Shut-off valve at inlet to trailer. Freeze<br />

protection above ground.<br />

3. SEWER: Accessible clean-out<br />

Proper Depth & Fall<br />

4. GAS: Proper Depth<br />

Proper flex connection<br />

Shut off valve @ inlet to trailer<br />

Gas pressure test<br />

5. ELECTRIC: Proper flex connection<br />

4-wire feed<br />

Wire size corresponds to breaker panel rating<br />

Neutral wires are isolated from box<br />

Main disconnect rating equal to panel rating<br />

6. SKIRTING: Do not put skirting on until after final inspection<br />

Some one needs to be there to let the inspector in <strong>for</strong> the final inspection.


DIAGRAM 1 DIAGRAM 2<br />

SUPPORT: An adjustable steel pier. The flange on the top of the pier shall be


PLOT


DIAGRAM 3<br />

SUPPORT AND FOOTING: One or no more than two concrete supports stacked<br />

vertically.<br />

WEDGES: There shall be no more than two wedges placed on each support, both


DIAGRAM 5<br />

SUPPORTS: More than two courses of Concrete Masonry Unit's (CMU's) building


GAS TESTING<br />

1) - Test Gauge (must measure in 1/10 Ib increments)


FOUR-WIRE, SINGLE-PHASE MOBILE / MANUFACTURED HOME FEEDER<br />

FEEDER CONDUCTOR TYPES AND SIZES<br />

RHW - THW - THHW - THWN - XHHW<br />

"HOT ll<br />

(BLACK)<br />

"NEUTRAL"<br />

(WHITE)<br />

"GROUND"<br />

(GREEN)<br />

SERVICE<br />

RATING<br />

COPPER<br />

ALUMINUM<br />

AND COPPER<br />

CLAD AL.<br />

SERVICE<br />

RATING<br />

COPPER<br />

ALUMINUM<br />

AND COPPER<br />

CLAD AL.<br />

SERVICE<br />

RATING<br />

COPPER<br />

ALUMINUM<br />

AND COPPER<br />

CLAD AL.<br />

AMPERES<br />

AWG<br />

AWG<br />

AMPERES<br />

AWG<br />

AWG<br />

AMPERES<br />

AWG<br />

AWG<br />

100<br />

4<br />

2<br />

100<br />

6<br />

2<br />

100<br />

8<br />

6<br />

125<br />

2<br />

1/0<br />

125<br />

3<br />

1<br />

125<br />

8<br />

6<br />

150<br />

1<br />

2/0<br />

150<br />

2<br />

1/0<br />

150<br />

6<br />

4<br />

175<br />

1/0<br />

3/0<br />

175<br />

2<br />

1/0<br />

175<br />

6<br />

4<br />

200<br />

2/0<br />

4/0<br />

200<br />

1<br />

2/0<br />

200<br />

6<br />

4<br />

STATE OF ARIZONA<br />

DEPARTMENT OF BUILDING & FIRE<br />

SAFETY