D) Chemical Protection<br />

If the risk of oil and chemicals affecting the installed cable cannot be excluded this may affect the operation<br />

of the cables in long term.<br />

The extent of the risk is determined by type, agressive nature, condition and quantity of the medium, the<br />

duration of immersion and the temperature.<br />

A suitable protection can be achieved by corresponding measures:<br />

Lead sheath (Pb)<br />

The safest, though most expensive protection<br />

against aromatic hydrocarbons and active<br />

chamicals.<br />

Design Options<br />

Multilayer sheath (L)2Y4Y<br />

This design combining aluminium tape and HDPE<br />

sheath with a covering of polyamide PA (Nylon),<br />

represents an excellent barrier against penetrating<br />

chemicals and can be used as an alternative to lead<br />

sheath.<br />

Advantage: lighter, smaller diameter.<br />

Oil resistant PVC-sheath Yö<br />

In contrast to standard PVC (Y) this compound is more resistant to oils and aliphatic hydrocarbons.<br />

It <strong>pa</strong>sses the oil resistance test according to IEC 60811-2-1.<br />

© KERPEN GmbH & Co. KG 2005 • 1.2007 • Printing errors excepted. Subject to alteration. H3