14.11.2014 Views

Monitoring voltage relay HRN-33, HRN-34, HRN-35 ...

Monitoring voltage relay HRN-33, HRN-34, HRN-35 ...

Monitoring voltage relay HRN-33, HRN-34, HRN-35 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Monitoring</strong> <strong>voltage</strong> <strong>relay</strong> <strong>HRN</strong>-<strong>33</strong>, <strong>HRN</strong>-<strong>34</strong>, <strong>HRN</strong>-<strong>35</strong><br />

Spannungsüberwachungsrelais <strong>HRN</strong>-<strong>33</strong>, <strong>HRN</strong>-<strong>34</strong>, <strong>HRN</strong>-<strong>35</strong><br />

Technical parameters<br />

Supply and measuring<br />

Terminals:<br />

Supply <strong>voltage</strong>:<br />

Consumption:<br />

Upper level (Umax):<br />

Bottom level (Umin):<br />

Time delay:<br />

Accuracy<br />

Setting accuracy (mechanical):<br />

Repeat accuracy:<br />

Dependance on temperature:<br />

Tolerance of limit values:<br />

Hysteresis (from fault to normal):<br />

Output<br />

Number of contacts:<br />

Rated current:<br />

Breaking capacity:<br />

Inrush current:<br />

Switching <strong>voltage</strong>:<br />

Min. breaking capacity DC:<br />

Output indication:<br />

Mechanical life:<br />

Electrical life:<br />

Operating temperature:<br />

Storage temperature:<br />

Electrical strength:<br />

Operating position:<br />

Mounting:<br />

Protection degree:<br />

Over<strong>voltage</strong> cathegory:<br />

Pollution degree:<br />

Max. cable size:<br />

Dimensions:<br />

Weight:<br />

Standards:<br />

Technische Daten<br />

Versorgung und Messung<br />

Versorgungs-, Meßklemmen:<br />

Versorgungsspannung:<br />

Leistungsaufnahme:<br />

Obenbereich (Umax):<br />

Untenbereich (Umin):<br />

Zeitverzögerung:<br />

Genauigkeit<br />

Einstellungsgenauigkeit:<br />

Wiederholgenauigkeit:<br />

Abhängung von Temperatur:<br />

Grenzwerttoleranz:<br />

Hysterese (aus Fehlerstand in OK.):<br />

Ausgang<br />

Anzahl der Wechsler:<br />

Nennstrom:<br />

Schaltleistung:<br />

Höchststrom:<br />

Schaltspannung:<br />

Min. Schaltleistung DC:<br />

Ausgangsanzeige:<br />

Mechanische Lebensdauer:<br />

Elektrische Lebensdauer:<br />

Umgebungstemperatur:<br />

Lagerstemperatur:<br />

Elektrische Festigkeit:<br />

Arbeitsstellung:<br />

Befestigung/DIN-Schiene:<br />

Schutzart:<br />

Spannungsbegrenzungsklasse:<br />

Verschmutzungsgrad:<br />

Anschlußquerschnitt:<br />

Abmessung:<br />

Gewicht:<br />

Normen:<br />

Supply from monitored <strong>voltage</strong><br />

(monitores level of its own supply)<br />

3-state indication - LEDs indicating normal<br />

state and 2 fault states<br />

Voltage Umin adjusted as % of Umax<br />

Adjustable delay0-10sec<br />

Adjustment of <strong>voltage</strong> levels and delay via potentiometers<br />

<strong>HRN</strong>-<strong>33</strong><br />

- U max AC 160 - 276 V<br />

- U min 30-99 % of U max.<br />

- U max and U min can be monitored independently<br />

<strong>HRN</strong>-<strong>34</strong><br />

- like <strong>HRN</strong>-<strong>33</strong> but <strong>voltage</strong> range is DC6-30V<br />

- monitoring of battery circuits (12, 24 V)<br />

<strong>HRN</strong>-<strong>35</strong> - like <strong>HRN</strong>-<strong>33</strong>, but independent output <strong>relay</strong>s for<br />

each <strong>voltage</strong> level<br />

- switching of other loads possible<br />

1-phase, 1-MODULE, DIN rail mounted<br />

<strong>HRN</strong>-<strong>33</strong><br />

<br />

<br />

<br />

<br />

<br />

Versorgung aus der Überwachungsspannung<br />

3-Standanzeige: LED (1x Normalstand und 2x Fehlerstand)<br />

Untenspannungsbereich (Umin) wird in % von<br />

Obenspannungsbereich (Umax) eingestellt<br />

Zeitverzögerung:0-10s<br />

Spannungsniveau-, Zeitverzörgerungseinstellung:<br />

durch Potentiometer<br />

<strong>HRN</strong>-<strong>33</strong><br />

- Umax AC 160 - 276 V<br />

- Umin 30-99 % von Obenniveau<br />

- Umin und Umax können selbständig überwacht werden<br />

<br />

<br />

<br />

<strong>HRN</strong>-<strong>34</strong> - wie <strong>HRN</strong>-<strong>33</strong>, aber mit Bereich DC 6 - 30 V<br />

- bestimmt für Überwachung von Baterienkreise (12, 24 V)<br />

<strong>HRN</strong>-<strong>35</strong> - wie <strong>HRN</strong>-<strong>33</strong>, hat jedoch selbständiges<br />

Ausgangsrelais für jedes Spannungsniveau<br />

- mögliche Schaltung von anderen Lasten<br />

<br />

1-Phase, 1-MODUL, Befestigung auf DIN-Schiene<br />

A1-A2 A1-A2 A1-A2<br />

in range of monitored <strong>voltage</strong> in range of monitored <strong>voltage</strong> in range of monitored <strong>voltage</strong><br />

AC/DC max. 1.2 VA AC/DC max. 1.2 VA AC/DC max. 1.2 VA<br />

AC 160 - 276 V<br />

DC6-30V<br />

AC 160 - 276 V<br />

30 - 99 % Umax 30 - 99 % Umax 30 - 99 % Umax<br />

adjustable0-10s adjustable0-10s adjustable0-10s<br />

1x changeover, AgNi<br />

red / green LED<br />

<strong>HRN</strong>-<strong>34</strong><br />

5% 5% 5%<br />

2-6 % of adjusted value<br />

2-6 % of adjusted value<br />

2-6 % of adjusted value<br />

16 A / AC1<br />

4000 VA / AC1, 384W/DC<br />

30A/


Functions / Funktionen<br />

Legend:<br />

Umax - upper adjustable level of <strong>voltage</strong><br />

Umax - Eingestellt-Obenspannungsniveau<br />

Un - measured <strong>voltage</strong><br />

Un - gemessene Spannung<br />

Umin - bottom adjustable level of <strong>voltage</strong><br />

Umin - Eingestellt - Untenspannungsniveau<br />

15-18 - switching contact of output <strong>relay</strong> No.1<br />

15-18 - Schaltkontakt des Ausgangsrelais Nr.1<br />

25-28 - switching contact of output <strong>relay</strong> No. 2<br />

25-28 - Schaltkontakt des Ausgangsrelais Nr.2<br />

LED > Un - indication green<br />

- Anzeige grün<br />

LED > < U - indication red<br />

- Anzeige rot<br />

LED<br />

<strong>HRN</strong>-<strong>33</strong>, <strong>HRN</strong>-<strong>34</strong><br />

Umax<br />

Un<br />

Umin<br />

15-18<br />

> Un<br />

LED U > <<br />

t<br />

Hysteresis<br />

t<br />

Hysteresis<br />

LED<br />

<strong>HRN</strong>-<strong>35</strong><br />

Umax<br />

Un<br />

Umin<br />

15-18<br />

25-28<br />

> Un<br />

LED U > <<br />

t<br />

Hysteresis<br />

t<br />

Hysteresis<br />

<<br />

230 Umax<br />

[V]<br />

253<br />

276<br />

4 5 6<br />

7<br />

8<br />

9<br />

10<br />

70<br />

80<br />

90<br />

99<br />

Umin<br />

[%Umax]<br />

Normal state<br />

Normalstand<br />

Umin <<br />

230 Umax<br />

[V]<br />

253<br />

276<br />

4 5 6<br />

7<br />

8<br />

9<br />

10<br />

70<br />

80<br />

90<br />

99<br />

Umin<br />

[%Umax]<br />

Upper level exceeded (over<strong>voltage</strong>)<br />

Obenniveau überschritten (Überspannung)<br />

Un>Umax<br />

green /grün LED = ON<br />

red / rot LED = ON<br />

><br />

U n<br />

184<br />

207<br />

160<br />

3<br />

t 2<br />

[s] 1<br />

0<br />

60<br />

50<br />

40<br />

30<br />

U > <<br />

230 Umax<br />

[V]<br />

253<br />

276<br />

4 5 6<br />

7<br />

8<br />

9<br />

10<br />

70<br />

80<br />

90<br />

99<br />

Umin<br />

[%Umax]<br />

Bottom level exceeded (under<strong>voltage</strong>)<br />

Untenniveau überschritten (Unterspannung)<br />

Un<br />

U h U > n <<br />

207 230 Umax<br />

184<br />

[V]<br />

253<br />

160<br />

276<br />

4 5 6<br />

3<br />

t<br />

7<br />

2<br />

8<br />

[s] 1<br />

9<br />

0<br />

10<br />

60<br />

50<br />

40<br />

30<br />

70<br />

80<br />

90<br />

99<br />

Umin<br />

[%Umax]<br />

Indication<br />

Anzeige<br />

Adjusting of time pause<br />

Einstellung der<br />

Zeitverzögerung<br />

Adjusting of upper value<br />

Einstellung des Obenniveaus<br />

Adjusting of bottom value<br />

Einstellung des Untenniveaus<br />

<strong>HRN</strong>-<strong>35</strong><br />

><br />

U h U > n <<br />

207 230 Umax<br />

184<br />

[V]<br />

253<br />

160<br />

276<br />

4 5 6<br />

3<br />

t<br />

7<br />

2<br />

8<br />

[s] 1<br />

9<br />

0<br />

10<br />

60<br />

50<br />

40<br />

30<br />

70<br />

80<br />

90<br />

99<br />

Umin<br />

[%Umax]<br />

Indication<br />

Anzeige<br />

Adjusting of time pause<br />

Einstellung der<br />

Zeitverzögerung<br />

ELKO<br />

Output contacts<br />

Ausgangskontakte<br />

Output contacts / Ausgangskontakte<br />

Output contacts / Ausgangskontakte<br />

41

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!