17.11.2014 Views

Technical Data Y.CT Universal - Instmed.com.br

Technical Data Y.CT Universal - Instmed.com.br

Technical Data Y.CT Universal - Instmed.com.br

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

+<strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +<<strong>br</strong> />

<strong>Technical</strong> <strong>Data</strong><<strong>br</strong> />

Y.<strong>CT</strong> <strong>Universal</strong><<strong>br</strong> />

YXLON.<strong>CT</strong> <strong>Universal</strong><<strong>br</strong> />

<strong>CT</strong> based X-ray Inspection System<<strong>br</strong> />

for a wide inspection item spectrum<<strong>br</strong> />

■ Various material testing<<strong>br</strong> />

■ Wide Inspection envelope<<strong>br</strong> />

■ Voluminous and heavy inspection items<<strong>br</strong> />

■ Line Detector and Flat Panel<<strong>br</strong> />

<strong>Universal</strong> test requirements require a universal test<<strong>br</strong> />

system. With the Y.<strong>CT</strong> <strong>Universal</strong>, a <strong>CT</strong> system is offered<<strong>br</strong> />

that meet these requirements. This flexibility is made<<strong>br</strong> />

possible by the <strong>com</strong>bination of a large test space, a<<strong>br</strong> />

manipulator for precise placement of items, a high<<strong>br</strong> />

energy X-ray source and a Line Array Detector and Flat<<strong>br</strong> />

Panel.<<strong>br</strong> />

The strengths of the Y.<strong>CT</strong> <strong>Universal</strong> <strong>com</strong>e into play<<strong>br</strong> />

when within the wide inspection item spectrum,<<strong>br</strong> />

voluminous and heavy <strong>com</strong>ponents need to be tested.<<strong>br</strong> />

For instance, engine blocks can be as precisely<<strong>br</strong> />

researched as spark plugs.<<strong>br</strong> />

This information is then available for the development<<strong>br</strong> />

of innovative products – which contributes to the<<strong>br</strong> />

economic strength of the <strong>com</strong>pany within the market.<<strong>br</strong> />

YXLON. The reason why.<<strong>br</strong> />

■ Application for research and development<<strong>br</strong> />

Y.<strong>CT</strong> <strong>Universal</strong><<strong>br</strong> />

YXLON. The reason why<<strong>br</strong> />

®


+<strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +++ <strong>Technical</strong> <strong>Data</strong> +<<strong>br</strong> />

<strong>Technical</strong> <strong>Data</strong><<strong>br</strong> />

Y.<strong>CT</strong> <strong>Universal</strong><<strong>br</strong> />

Measurement Computed Tomography Line Detector Array Slice images / Fan beam<<strong>br</strong> />

modes Computed Tomography Flat Panel Volume scan / Cone beam<<strong>br</strong> />

Continuous rotation / stop & go mode<<strong>br</strong> />

Radiography<<strong>br</strong> />

Digital radiography / Real time<<strong>br</strong> />

X-ray system X-ray system (see also separate datasheet) MG 452<<strong>br</strong> />

X-ray tube Y.TU 450-D02<<strong>br</strong> />

Tube voltage / Tube current<<strong>br</strong> />

60 - 450 keV / 2.0 - 9.0 mA<<strong>br</strong> />

Power<<strong>br</strong> />

900 W<<strong>br</strong> />

Focal spot according to EN12543<<strong>br</strong> />

2.5 mm<<strong>br</strong> />

Cooling<<strong>br</strong> />

Supplies<<strong>br</strong> />

<strong>Data</strong> subject to change without notice. Printed in Germany. 9499.211.16010.FC01<<strong>br</strong> />

Oil-Water / Oil-Air<<strong>br</strong> />

Filter kit and collimators<<strong>br</strong> />

alternative alternative optional<<strong>br</strong> />

Line Detector Array Line Detector Array Flat Panel<<strong>br</strong> />

Inspection Inspection item weight 75 kg 75 kg 75 kg<<strong>br</strong> />

envelope inspection item height 1,200 mm 1,200 mm 1,200 mm<<strong>br</strong> />

Inspection item max. diameter 505 mm 620 mm 315 mm<<strong>br</strong> />

630 mm (horizontal<<strong>br</strong> />

scan field extension)<<strong>br</strong> />

Performance Spatial resolution 73 - 195 µm 73 - 195 µm 115 - 300 µm<<strong>br</strong> />

Contrast resolution 1 % 1 % 1 %<<strong>br</strong> />

Scan time 15 sec 15 sec 300 ms / Projektion<<strong>br</strong> />

(1024 2 Pixel)<<strong>br</strong> />

Scan time<<strong>br</strong> />

incl. reconstruction 30 sec 30 sec<<strong>br</strong> />

Reconstruction<<strong>br</strong> />

YXLON International X-Ray GmbH,<<strong>br</strong> />

Essener Bogen 15, D-22419 Hamburg, Phone: +49 40 527 29 - 0,<<strong>br</strong> />

Fax: +49 40 527 29 -170, E-mail: yxlon@hbg.yxlon.<strong>com</strong>, http://www.yxlon.<strong>com</strong><<strong>br</strong> />

®<<strong>br</strong> />

Inline Reconstruction<<strong>br</strong> />

512 2 Voxel, 360 Projections<<strong>br</strong> />

approx. 100 sec<<strong>br</strong> />

Imaging Type of Detector Line Det. Array LDA2604-250-5X Line Det. Array LDA3224-250-5X Flat Panel PE RID 1640 <strong>CT</strong><<strong>br</strong> />

system Format / Sensor 651 mm effective length 806 mm effective length 409,6 x 409,6 mm 2 Sensor area<<strong>br</strong> />

Resolution / Pitch 2604 Pixel / 250 µm 3224 Pixel / 250 µm 1024 x 1024 Pixel / 400 µm<<strong>br</strong> />

Dynamic 16 bit 16 bit 16 bit<<strong>br</strong> />

Imaging Magnification 1.25 - 3.33 times 1.25 - 3.33 times 1.25 - 3.33 times<<strong>br</strong> />

parameters Minimal Focus-Detector-Distance 1,000 mm 1,000 mm 1,000 mm<<strong>br</strong> />

Maximum Focus-Detector-Distance 2,000 mm 2,000 mm 2,000 mm<<strong>br</strong> />

Manipulator Material Steel / Granite<<strong>br</strong> />

Dimensions (Length x Depth x Height) 3,800 x 1,300 x 2,850 mm 3<<strong>br</strong> />

Weight<<strong>br</strong> />

6 t<<strong>br</strong> />

Turntable diameter<<strong>br</strong> />

400 mm / plane surface, witch notches<<strong>br</strong> />

- max. speed / precision 45 °/s / 0,04 °<<strong>br</strong> />

Longitudinal axis turntable<<strong>br</strong> />

1,500 mm<<strong>br</strong> />

- max. speed / precision 50 mm/s / < 50 µm<<strong>br</strong> />

Vertical axis X-ray source 450 kV<<strong>br</strong> />

1,200 mm<<strong>br</strong> />

- max. speed / precision 50 mm/s / 50µm<<strong>br</strong> />

Vertical axis detectors<<strong>br</strong> />

1,200 mm<<strong>br</strong> />

- max. speed / precision 50 mm/s / 50µm<<strong>br</strong> />

Longitudinal axis detectors<<strong>br</strong> />

1,100 mm<<strong>br</strong> />

- max. speed / precision 50 mm/s / 50µm<<strong>br</strong> />

Traverse axis Flat Panel (scan field extension)<<strong>br</strong> />

500 mm<<strong>br</strong> />

- max. speed / precision 50 mm/s / 50µm<<strong>br</strong> />

Radiation Radiation protection cabin Customized radiation protection solutions<<strong>br</strong> />

protection<<strong>br</strong> />

Typical mass for walkable cabin (L x W x H):<<strong>br</strong> />

5,500 x 3,000 x 3,200 mm 3<<strong>br</strong> />

Control unit Operators Desk with two 19 " TFT Monitors<<strong>br</strong> />

Computer server cabinet with X-ray operation sector<<strong>br</strong> />

Software Control software Y.<strong>CT</strong> Control Software<<strong>br</strong> />

Y.<strong>CT</strong> Inline Reconstruction<<strong>br</strong> />

Analysis software<<strong>br</strong> />

3D Volume Software VG Studio<<strong>br</strong> />

Environment Power supply 3 phases + PE + N 63 A / 400 V / 50 Hz<<strong>br</strong> />

Ambient air temperature 20 - 25 °C<<strong>br</strong> />

Humidity<<strong>br</strong> />

30 - 70 %, no condensation<<strong>br</strong> />

Optiones Monitoring camera<<strong>br</strong> />

Laser for indicate slice position<<strong>br</strong> />

Hand-held control for manipulator<<strong>br</strong> />

Active vi<strong>br</strong>ation absorber<<strong>br</strong> />

Software<<strong>br</strong> />

e.g. VG Studio Max, Nom. / Act. Value Comp.<<strong>br</strong> />

Measurement Software, Reverse Engineering<<strong>br</strong> />

Customized At customer request configurations are freely eligible