7. Fault rectification by the qualified installer<br />

22<br />

Code enquiry<br />

<strong>LCD</strong> display Button Note<br />

Fault / defect code / Info Possible cause / defect Rectification<br />

No display in the control panel.<br />

� Menu selection.<br />

� Code enquiry for service.<br />

No voltage.<br />

No connection to the control unit.<br />

Control unit defective.<br />

Restore voltage supply.<br />

Check that connector „X2“ is correctly<br />

fitted H .<br />

Check control unit (21) and if necessary<br />

replace.<br />

Ca-scale symbol shows Heating element scaled. Heating continues. Descale element. Symbol will disappear.<br />

Service symbol.<br />

Code Continuous display -<br />

setpoint temperature.<br />

Code<br />

Code No anode protection.<br />

Code Last preset setpoint values<br />

active. Possibly continuous<br />

display of .<br />

Defect symbol >> flashing.<br />

Code Continuous display -<br />

setpoint temperature.<br />

Code No heating-up symbol.<br />

Code Running dry protection.<br />

Water heating continues.<br />

Maintenance requirement.<br />

Temperature sensor fault.<br />

Parasitic current anode fault.<br />

Communication fault with electronic<br />

„regulator“ and „control unit“ modules.<br />

No water heating. Defect code enquiry.<br />

Corrective maintenance urgently<br />

required!<br />

Temperature sensor defective.<br />

Safety thermal cut-out (STB) actuated.<br />

Service code enquiry.<br />

Service / maintenance required.<br />

Check that connector „X10“ is correctly<br />

fitted L . Inspect temperature sensor.<br />

Check that connector „X7“ is correctly<br />

fitted L . Check parasitic current anode and<br />

wiring.<br />

Check that connector „X2“ is correctly<br />

fitted on both modules H .<br />

Check connection cable and modules.<br />

Check that connector „X10“ is correctly<br />

fitted L . Inspect temperature sensor.<br />

Eliminate error and reset thermal cut out.<br />

Heating element defective. Rectify cause and unlock; inspect STB and if<br />

necessary replace.<br />

No water in the reservoir.<br />

Fill the reservoir with water.<br />

No anode current. Check that connector „X7“ is correctly<br />

fitted L . Inspect parasitic current anode<br />

and wiring.<br />

Code Relay defective. Replace regulator electronic module (23).