Design Development Report January 2011<br />

5.3 MECHANICAL<br />

Mechanical systems for this facility will be selected in order to achieve a LEED<br />

silver rating. Air system will be located in the Mechanical Room and be ducted to<br />

displacement air grilles at low levels in all rooms. Air system will use 100% outside air<br />

with heat recovery. Plumbing systems will utilize low consumption fixtures c/w high<br />

efficiency water heater. Building heating system will utilize two medium efficient boilers<br />

and distribution pumps to heating radiant panels in the various spaces. Controls will be<br />

direct digital type.<br />

5.4 ELECTRICAL<br />

<strong>The</strong> electrical service and distribution for this building will include a utility fed<br />

transformer supplying a 120/208 volt, 3 phase, 4 wire secondary power service to a main<br />

distribution centre located in the Electrical Room. Branch circuit panelboards will be<br />

used to feed downstream devices such as mechanical loads, fluorescent lighting and<br />

duplex receptacles. A motor control center fed via the main distribution panel will be<br />

used to supply power to required mechanical loads. Duplex receptacles will be provided<br />

throughout the building for convenience, and as required by the identified building<br />

equipment. Lighting will be fluorescent throughout including high bay T5 fluorescent<br />

fixtures in the main gymnasium with T8 fluorescent fixtures throughout the remaining<br />

support spaces. Lighting controls will include microphonic/IR occupancy sensors in the<br />

main gymnasium and washroom/change room areas and occupancy sensors in the <strong>of</strong>fice<br />

and common areas. <strong>The</strong> gymnasium will have three level lighting and the remaining<br />

<strong>of</strong>fice, change room and common areas will be two level lighting. <strong>The</strong> main gymnasium<br />

will also have daylight sensors incorporated to account for additional daylight through<br />

the proposed windows. Emergency and exit lighting will be supplied in accordance with<br />

the requirements <strong>of</strong> the Alberta Building Standards, with the use <strong>of</strong> battery power as<br />

backup.<br />

Telephone service and distribution will include a utility feed to the main Telephone/<br />

Data backboard in the Electrical Room, from which point an empty conduit system will<br />

be provided throughout the building to serve outlets in <strong>of</strong>fice areas and other areas as<br />

required. <strong>The</strong> fire alarm and smoke detection system will be a class A system with battery<br />

backup and will include a main panel at the front entrance with initiating and signaling<br />

devices as required based on the code. <strong>The</strong> building and gymnasium sound systems<br />

will be provided for as directed by the <strong>City</strong> <strong>of</strong> <strong>Spruce</strong> <strong>Grove</strong>. Electrical systems will be<br />

designed in this building in order to achieve a LEED Silver rating.<br />