<strong>CelliGen</strong> <strong>BLU</strong> Bioreactor Specifications 1<br />

Total Volume 5.0 Liters 14.0 Liters<br />

Single-Use<br />

Cell Culture Vessel<br />

Working Volume 3.75 Liters 10.5 Liters<br />

Minimum Volume 1.25 Liters 3.5 Liters<br />

Controls up to 32 control loops; stores 10 recipes and 8 process variables for trend graphing.<br />

Controller<br />

Control Station<br />

Includes an industrial touchscreen monitor/user interface, 3 built-in pumps and connectors for<br />

all utilities and <strong>com</strong>munications signals<br />

Touchscreen Interface/Display 15-inch (38.1 cm) color industrial monitor with adjustable-angle swivel<br />

Indication<br />

Digital display in 0.1°C increments<br />

Temperature<br />

Range From 5°C above ambient temperature to 40°C<br />

Control<br />

P&I for heating using a Heat Blanket (cooling via ambient environment)<br />

Sensor<br />

Platinum RTD probe<br />

Drive<br />

Permanent magnet motor with high torque input<br />

Indication<br />

Digital display in 1 rpm increments<br />

Agitation<br />

Range<br />

25 - 200 rpm<br />

Control<br />

PI-controlled<br />

Impellers<br />

Pitched blade (upflow or downflow selectable via touchscreen)<br />

Exhaust<br />

Filter<br />

0.2 µm disposable filter<br />

Tube<br />

Heat blanketed<br />

3- or 4-Gas System Up to 4 gases, including air, N 2 , CO 2 and O 2 , delivered to sparge and overlay<br />

Flow Control<br />

Automatic or manual options<br />

Aeration<br />

Sparge<br />

1, 3 or 4 TMFCs (0.002 - 0.1 SLPM) – Automatic option<br />

1 Rotameter (0.001 - 0.1 SLPM) – Manual option<br />

Optional Overlay<br />

1 TMFC (0.1 - 3.0 SLPM) – Automatic option<br />

1 Rotameter (0.1 - 3.3 SLPM) – Manual option<br />

Sparge Element<br />

Porous microsparger (6 - 12 µm)<br />

Inlet Filters<br />

0.2 µm disposable filter<br />

Indication<br />

Digital display in 0.01 pH increments<br />

pH<br />

Range<br />

6 - 8 pH<br />

Control<br />

P&I<br />

Probe<br />

Noninvasive optical pH probe. Single-use fluorescence sensor is included with each vessel<br />

Indication<br />

Digital display in 0.1% increments<br />

DO<br />

Range 0 - 200%<br />

Control<br />

P&I<br />

Probe<br />

Noninvasive, reusable polarographic probe<br />

Assignable high-performance peristaltic pump<br />

Pump 1<br />

Fixed speed (14 rpm) or variable-duty cycle<br />

Pumps<br />

Available control modes: Off, On, Prime<br />

Assignable high-performance peristaltic pumps<br />

Pumps 2 and 3<br />

Fixed speed (109 rpm) or variable-duty cycle<br />

Available control modes: Off, On, Prime<br />

Utilities Gas 5 - 6 PSIG maximum<br />

Electrical Requirements<br />

100 - 120 VAC 50/60 Hz, Single phase, 15 Amps<br />

200 - 240 VAC 50/60 Hz, Single phase, 15 Amps<br />

Control Station<br />

88 lbs. (40 kg) with touchscreen<br />

Net Weight<br />

Touchscreen<br />

15 lbs. (6.8 kg)<br />

Vessel empty without motor 2 5.0 liter vessel: 2.9 lbs. (1.3 kg) 14.0 liter vessel: 3.9 lbs. (1.8 kg)<br />

Overall Dimensions<br />

(W x D x H)<br />

Control Station & Vessel 25 x 24 x 34 inches (63 x 61 x 86 cm), including touchscreen<br />

Input/Output Connections<br />

Analog Inputs/Outputs<br />

Up to 7 analog inputs and up to 7 analog outputs to add auxiliary equipment, usable as follows:<br />

TMFC configuration<br />

••<br />

3 inputs and 3 outputs – interchangeable 0 – 5 V or 4 – 20 mA<br />

••<br />

Up to 4 additional 0 – 5 V inputs and 4 additional 0 – 5 V outputs available, depending on<br />

and Comm Ports<br />

Import firmware/software upgrades and export trend data<br />

2 USB Ports<br />

Connect optional 8-port serial box for scales, etc.<br />

Communications Port<br />

For optional BioCommand ® /SCADA software<br />

Ambient Operating Conditions<br />

10 - 30°C up to 80% relative humidity, non-condensing<br />

Regulatory Compliance<br />

CAN/CSA-C22.2 Nos. 1010.1 & 1010.2.010<br />

UL Standard UL-61010A-1 & 61010A-2-010<br />

1. Specifications subject to change without notice. 2. Vessel weight does not include probes, exhaust heater or other options.<br />

<strong>CelliGen</strong> and BioCommand are trademarks of New Brunswick Scientific. C-Flex is a trademark of Saint-Gobain Plastics. Clave is a trademark of ICU Medical, Inc.<br />

New Brunswick Scientific - A culture of innovation<br />

USA Headquarters PO Box 4005, Edison, NJ 08818-4005 • bioinfo@nbsc.<strong>com</strong><br />

800.631.5417 • 1.732.287.1200 • Fax: 1.732.287.4222 • www.nbsc.<strong>com</strong><br />

B-4025 10XC1009