SleepCube BiLevel ST brochure - DeVilbiss Healthcare
SleepCube BiLevel ST brochure - DeVilbiss Healthcare
SleepCube BiLevel ST brochure - DeVilbiss Healthcare
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>BiLevel</strong> <strong>ST</strong>
The <strong>SleepCube</strong> <strong>BiLevel</strong> <strong>ST</strong> from <strong>DeVilbiss</strong><br />
<strong>Healthcare</strong> gives you the function and<br />
performance required to aid in the<br />
therapy of respiratory insufficiency,<br />
obstructive and central sleep apnoea.<br />
The <strong>BiLevel</strong> <strong>ST</strong> utilises the attractive<br />
design of the <strong>SleepCube</strong> range, which is<br />
widely recognised for its low noise and<br />
high performance. With features usually<br />
found in much larger devices such as<br />
separate IPAP and EPAP flow adjustment<br />
the <strong>SleepCube</strong> <strong>BiLevel</strong> <strong>ST</strong> offers a cost<br />
effective solution. As part of the <strong>SleepCube</strong><br />
range it is fully compatible with the<br />
<strong>SleepCube</strong> integrated humidifier system<br />
and SmartLink data compliance module<br />
and PC software. With a full range of<br />
accessories available, the <strong>SleepCube</strong><br />
<strong>BiLevel</strong> <strong>ST</strong> is equally beneficial in the<br />
hospital or home environment.<br />
Key features<br />
Four modes: CPAP, Spontaneous,<br />
Spontaneous Timed and Timed only<br />
■■<br />
Up to 25 cm H 2 O<br />
■■<br />
Whisper quiet<br />
■■<br />
Easy to use<br />
■■<br />
IPAP and EPAP pressure adjustments<br />
■■<br />
SmartCode as standard<br />
■■<br />
Integrated humidifier available<br />
■■<br />
Optional SmartLink data compliance<br />
module and software<br />
■■<br />
Real Time Display showing measured<br />
pressure, trigger source (Spontaneous<br />
or Timed), breath state (inspiration /<br />
expiration), I : E ratio and percentage<br />
inhale. Real-time data also includes:<br />
Respiratory Rate, Leak, Event Markers,<br />
Minute Volume, and Tidal Volume.<br />
Trigger<br />
The trigger within the <strong>BiLevel</strong> <strong>ST</strong> can be<br />
The simple LED push button display, makes the<br />
<strong>SleepCube</strong> easy to use, even in the dark<br />
The heated humidifier is easy to take apart and clean<br />
<strong>SleepCube</strong> <strong>BiLevel</strong> <strong>ST</strong> with integrated humidifier<br />
Back of the <strong>SleepCube</strong> – showing filter, patient tubing outlet and download outlet
customized to meet the patients’ needs.<br />
The sensitivity of the trigger can be<br />
adjusted on a scale of 1 – 10 (1 being the<br />
most sensitive). Separate Inspiratory and<br />
Expiratory trigger sensitivity settings are<br />
provided.<br />
Pressure Rounding<br />
Pressure Rounding is a patented<br />
technology from <strong>DeVilbiss</strong> <strong>Healthcare</strong><br />
which eases the transition from IPAP to<br />
EPAP by tailoring the users’ requirements<br />
to achieve optimal therapy and patient<br />
comfort over five levels.<br />
Pressure (cm H 2 O)<br />
11<br />
10<br />
9<br />
8<br />
7<br />
6<br />
5<br />
4<br />
0 0.5 1 1.5 2 2.5 3<br />
Time (sec)<br />
Wave form without Pressure Rounding<br />
Pressure (cm H 2 O)<br />
11<br />
10<br />
9<br />
8<br />
7<br />
6<br />
5<br />
4<br />
0 0.5 1 1.5 2 2.5 3<br />
Time (sec)<br />
Selectable IPAP and EPAP Pressure Rounding<br />
Connecting the SmartLink Module to the<br />
<strong>SleepCube</strong> <strong>BiLevel</strong> <strong>ST</strong> allows for the<br />
recording of patient data and the ability<br />
to transfer it by an SD card to a PC for<br />
further analysis and reporting using the<br />
SmartLink Software package. Device<br />
settings can also be updated using the<br />
data card (by sending a configured card<br />
out to patient).<br />
The optional hardware or software<br />
remote control connects directly to the<br />
<strong>SleepCube</strong> or via the SmartLink, which<br />
enables the <strong>SleepCube</strong> to be adjusted<br />
from a remote workstation. The<br />
SmartLink also offers the option of<br />
connecting a pulse oximeter to the<br />
<strong>SleepCube</strong> for recording and reporting<br />
additional oximetry data.<br />
Complete SmartLink compliance system<br />
including pulse oximetry<br />
Analysis using the SmartLink Software<br />
Complete compliance package
SmartCode is a very simple and cost<br />
effective way of retrieving patient<br />
adherence data from the <strong>SleepCube</strong> at<br />
any time. Simply obtain the SmartCode<br />
displayed in the <strong>SleepCube</strong> display<br />
window and enter it into the SmartCode<br />
software program. The code is then<br />
deciphered by the program and up to<br />
the last 90 days of patent adherence<br />
data is displayed on an easy to view<br />
report. SmartCode is a standard feature<br />
throughout the <strong>SleepCube</strong> range and<br />
the software is available online or as a<br />
desktop version.<br />
S P E C I F I C A T I O N S<br />
Dimensions (H x W x L)<br />
10.7 x 16.5 x 17.5 cm<br />
Weight<br />
1.22 kg<br />
Electrical Requirements AC<br />
100 - 240 V, 50/60 Hz<br />
Electrical Requirements DC<br />
10.4 - 15 V, 5 Amps<br />
Maximum Power Consumption<br />
65 watts (from AC power source)<br />
<strong>BiLevel</strong> Pressure Range<br />
3 - 25 cm H 2 O<br />
Operating Temperature Range<br />
5° C to 40° C<br />
Operating Humidity Range<br />
0 % to 95 % R.H. non-condensing<br />
Operating Atmospheric Conditions<br />
Sea level to 2,600 m<br />
Sound Level<br />
26 dBA (tested per ISO 17510)<br />
Events/Hour<br />
%<br />
Machine Inspiration<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
32<br />
30<br />
26<br />
20 16<br />
19<br />
10<br />
0<br />
Last 90 Days Last 30 Days Last 7 Days Last Day<br />
Apnea/Hypopnea Index<br />
35<br />
30<br />
25<br />
20<br />
15<br />
10<br />
5.5<br />
5.5<br />
5<br />
5 5<br />
0<br />
Last 90 Days Last 30 Days Last 7 Days Last Day<br />
Non-Responding Event Index<br />
35<br />
30<br />
% of Time Used<br />
%<br />
Machine Exspiration<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
35<br />
30<br />
23<br />
19<br />
20<br />
10<br />
10<br />
0<br />
Last 90 Days Last 30 Days Last 7 Days Last Day<br />
High Leak Flow Time (>95 L/Min)<br />
35<br />
30<br />
25<br />
20<br />
15<br />
12<br />
10<br />
10<br />
9<br />
10<br />
5<br />
0<br />
Last 90 Days Last 30 Days Last 7 Days Last Day<br />
Exhale Puff Index<br />
35<br />
30<br />
Equipment classification with respect to<br />
protection from electric shock<br />
Class II<br />
Degree of protection from electric shock<br />
Type BF Applied Part<br />
Degree of protection against<br />
ingress of liquids<br />
IPX1<br />
Events/Hour<br />
25<br />
20<br />
15<br />
10<br />
5<br />
0<br />
1.75<br />
1.5 1<br />
0.25<br />
Last 90 Days Last 30 Days Last 7 Days Last Day<br />
SmartCode Reports<br />
Events/Hour<br />
25<br />
20<br />
15<br />
10<br />
5<br />
0<br />
2<br />
Last 90 Days<br />
2<br />
Last 30 Days<br />
3<br />
Last 7 Days<br />
1<br />
Last Day<br />
Operation Modes<br />
CPAP, Spontaneous, Spontaneous Timed<br />
and Timed only<br />
<strong>DeVilbiss</strong> <strong>Healthcare</strong> Ltd.<br />
Unit 3, Bloomfield Park, Bloomfield Road<br />
Tipton, West Midlands DY4 9AP<br />
United Kingdom<br />
Phone + 44 (0) 121 521 3140<br />
Fax + 44 (0) 121 521 3141<br />
www.devilbisshc.com<br />
enquiries@devilbisshc.com<br />
Distributor:<br />
<strong>DeVilbiss</strong> <strong>Healthcare</strong> has a policy of continuing improvement, we therefore reserve the right to vary details at any<br />
time without notice. <strong>SleepCube</strong>, SmartLink and SmartCode are registered trademarks of <strong>DeVilbiss</strong> <strong>Healthcare</strong>.<br />
0310/2000/<strong>ST</strong>-serv/000690196.UK