<strong>BiLevel</strong> <strong>ST</strong>


The <strong>SleepCube</strong> <strong>BiLevel</strong> <strong>ST</strong> from <strong>DeVilbiss</strong><br />

<strong>Healthcare</strong> gives you the function and<br />

performance required to aid in the<br />

therapy of respiratory insufficiency,<br />

obstructive and central sleep apnoea.<br />

The <strong>BiLevel</strong> <strong>ST</strong> utilises the attractive<br />

design of the <strong>SleepCube</strong> range, which is<br />

widely recognised for its low noise and<br />

high performance. With features usually<br />

found in much larger devices such as<br />

separate IPAP and EPAP flow adjustment<br />

the <strong>SleepCube</strong> <strong>BiLevel</strong> <strong>ST</strong> offers a cost<br />

effective solution. As part of the <strong>SleepCube</strong><br />

range it is fully compatible with the<br />

<strong>SleepCube</strong> integrated humidifier system<br />

and SmartLink data compliance module<br />

and PC software. With a full range of<br />

accessories available, the <strong>SleepCube</strong><br />

<strong>BiLevel</strong> <strong>ST</strong> is equally beneficial in the<br />

hospital or home environment.<br />

Key features<br />

Four modes: CPAP, Spontaneous,<br />

Spontaneous Timed and Timed only<br />

■■<br />

Up to 25 cm H 2 O<br />

■■<br />

Whisper quiet<br />

■■<br />

Easy to use<br />

■■<br />

IPAP and EPAP pressure adjustments<br />

■■<br />

SmartCode as standard<br />

■■<br />

Integrated humidifier available<br />

■■<br />

Optional SmartLink data compliance<br />

module and software<br />

■■<br />

Real Time Display showing measured<br />

pressure, trigger source (Spontaneous<br />

or Timed), breath state (inspiration /<br />

expiration), I : E ratio and percentage<br />

inhale. Real-time data also includes:<br />

Respiratory Rate, Leak, Event Markers,<br />

Minute Volume, and Tidal Volume.<br />

Trigger<br />

The trigger within the <strong>BiLevel</strong> <strong>ST</strong> can be<br />

The simple LED push button display, makes the<br />

<strong>SleepCube</strong> easy to use, even in the dark<br />

The heated humidifier is easy to take apart and clean<br />

<strong>SleepCube</strong> <strong>BiLevel</strong> <strong>ST</strong> with integrated humidifier<br />

Back of the <strong>SleepCube</strong> – showing filter, patient tubing outlet and download outlet


customized to meet the patients’ needs.<br />

The sensitivity of the trigger can be<br />

adjusted on a scale of 1 – 10 (1 being the<br />

most sensitive). Separate Inspiratory and<br />

Expiratory trigger sensitivity settings are<br />

provided.<br />

Pressure Rounding<br />

Pressure Rounding is a patented<br />

technology from <strong>DeVilbiss</strong> <strong>Healthcare</strong><br />

which eases the transition from IPAP to<br />

EPAP by tailoring the users’ requirements<br />

to achieve optimal therapy and patient<br />

comfort over five levels.<br />

Pressure (cm H 2 O)<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

0 0.5 1 1.5 2 2.5 3<br />

Time (sec)<br />

Wave form without Pressure Rounding<br />

Pressure (cm H 2 O)<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

0 0.5 1 1.5 2 2.5 3<br />

Time (sec)<br />

Selectable IPAP and EPAP Pressure Rounding<br />

Connecting the SmartLink Module to the<br />

<strong>SleepCube</strong> <strong>BiLevel</strong> <strong>ST</strong> allows for the<br />

recording of patient data and the ability<br />

to transfer it by an SD card to a PC for<br />

further analysis and reporting using the<br />

SmartLink Software package. Device<br />

settings can also be updated using the<br />

data card (by sending a configured card<br />

out to patient).<br />

The optional hardware or software<br />

remote control connects directly to the<br />

<strong>SleepCube</strong> or via the SmartLink, which<br />

enables the <strong>SleepCube</strong> to be adjusted<br />

from a remote workstation. The<br />

SmartLink also offers the option of<br />

connecting a pulse oximeter to the<br />

<strong>SleepCube</strong> for recording and reporting<br />

additional oximetry data.<br />

Complete SmartLink compliance system<br />

including pulse oximetry<br />

Analysis using the SmartLink Software<br />

Complete compliance package


SmartCode is a very simple and cost<br />

effective way of retrieving patient<br />

adherence data from the <strong>SleepCube</strong> at<br />

any time. Simply obtain the SmartCode<br />

displayed in the <strong>SleepCube</strong> display<br />

window and enter it into the SmartCode<br />

software program. The code is then<br />

deciphered by the program and up to<br />

the last 90 days of patent adherence<br />

data is displayed on an easy to view<br />

report. SmartCode is a standard feature<br />

throughout the <strong>SleepCube</strong> range and<br />

the software is available online or as a<br />

desktop version.<br />

S P E C I F I C A T I O N S<br />

Dimensions (H x W x L)<br />

10.7 x 16.5 x 17.5 cm<br />

Weight<br />

1.22 kg<br />

Electrical Requirements AC<br />

100 - 240 V, 50/60 Hz<br />

Electrical Requirements DC<br />

10.4 - 15 V, 5 Amps<br />

Maximum Power Consumption<br />

65 watts (from AC power source)<br />

<strong>BiLevel</strong> Pressure Range<br />

3 - 25 cm H 2 O<br />

Operating Temperature Range<br />

5° C to 40° C<br />

Operating Humidity Range<br />

0 % to 95 % R.H. non-condensing<br />

Operating Atmospheric Conditions<br />

Sea level to 2,600 m<br />

Sound Level<br />

26 dBA (tested per ISO 17510)<br />

Events/Hour<br />

%<br />

Machine Inspiration<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

32<br />

30<br />

26<br />

20 16<br />

19<br />

10<br />

0<br />

Last 90 Days Last 30 Days Last 7 Days Last Day<br />

Apnea/Hypopnea Index<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5.5<br />

5.5<br />

5<br />

5 5<br />

0<br />

Last 90 Days Last 30 Days Last 7 Days Last Day<br />

Non-Responding Event Index<br />

35<br />

30<br />

% of Time Used<br />

%<br />

Machine Exspiration<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

35<br />

30<br />

23<br />

19<br />

20<br />

10<br />

10<br />

0<br />

Last 90 Days Last 30 Days Last 7 Days Last Day<br />

High Leak Flow Time (>95 L/Min)<br />

35<br />

30<br />

25<br />

20<br />

15<br />

12<br />

10<br />

10<br />

9<br />

10<br />

5<br />

0<br />

Last 90 Days Last 30 Days Last 7 Days Last Day<br />

Exhale Puff Index<br />

35<br />

30<br />

Equipment classification with respect to<br />

protection from electric shock<br />

Class II<br />

Degree of protection from electric shock<br />

Type BF Applied Part<br />

Degree of protection against<br />

ingress of liquids<br />

IPX1<br />

Events/Hour<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

1.75<br />

1.5 1<br />

0.25<br />

Last 90 Days Last 30 Days Last 7 Days Last Day<br />

SmartCode Reports<br />

Events/Hour<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

2<br />

Last 90 Days<br />

2<br />

Last 30 Days<br />

3<br />

Last 7 Days<br />

1<br />

Last Day<br />

Operation Modes<br />

CPAP, Spontaneous, Spontaneous Timed<br />

and Timed only<br />

<strong>DeVilbiss</strong> <strong>Healthcare</strong> Ltd.<br />

Unit 3, Bloomfield Park, Bloomfield Road<br />

Tipton, West Midlands DY4 9AP<br />

United Kingdom<br />

Phone + 44 (0) 121 521 3140<br />

Fax + 44 (0) 121 521 3141<br />

www.devilbisshc.com<br />

enquiries@devilbisshc.com<br />

Distributor:<br />

<strong>DeVilbiss</strong> <strong>Healthcare</strong> has a policy of continuing improvement, we therefore reserve the right to vary details at any<br />

time without notice. <strong>SleepCube</strong>, SmartLink and SmartCode are registered trademarks of <strong>DeVilbiss</strong> <strong>Healthcare</strong>.<br />

0310/2000/<strong>ST</strong>-serv/000690196.UK

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!