Example 3: Measured Flow Other Establishments<br />

Establishment: Campground<br />

Period Measured: Fourth of July Week.<br />

Daily flow measurements (gals) and utilization rate (%):<br />

Day Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7<br />

Measured Flow (gpd) 3,000 3,500 5,000 4,000 4,200 4,000 3,200<br />

Percent Utilized (in<br />

decimal <strong>for</strong>m)<br />

Extrapolated <strong>for</strong> max.<br />

capacity (flow / %<br />

capacity)<br />

Calculation of measured average daily flow:<br />

0.60 0.75 0.90 0.85 0.85 0.85 0.65<br />

5,000 4,667 5,556 4,705 4,940 4,705 4,923<br />

(5,000 + 4,667 + 5,556 + 4,705 + 4,940 + 4,705 + 4923) / 7 = 4,928 gallons + Inflow and Infiltration<br />

Step C2 — (question repeated) Will a single SSTS or group of SSTSs under single ownership within<br />

one-half mile of each other be designed to treat a design AWW flow greater than 10,000<br />

gallons per day as determined below?<br />

Yes — the system requires SDS permit from the <strong>MPCA</strong>. Please see<br />

www.pca.state.mn.us/programs/ists/business.html#largeists.<br />

No — Go to Step C3.<br />

Step C3 — Will the SSTS or group of SSTSs cause adverse public health or environmental impacts if<br />

not regulated under a state permit (such as systems in environmentally sensitive areas, those<br />

with unsubstantiated or unexpected flow volumes, or systems requiring exceptional<br />

operation, monitoring and management)?<br />

Yes — The system may need a SDS permit issued by the <strong>MPCA</strong>. Please see<br />

www.pca.state.mn.us/programs/ists/business.html#largeists.<br />

No — The system is regulated under a LGU permit. Contact the local permitting authority<br />

(either county environmental health or planning and zoning office, or township office<br />

or city building inspector).<br />

Step C4 — Does the system serve fewer than four dwellings or does it serve an Other Establishment with<br />

a design AWW flow of 2,500 gallons per day or less? (See Attachment 2 to calculate flow.)<br />

Yes —The system is an individual sewage treatment system (ISTS).<br />

No — The system qualifies as a midsized sewage treatment system (MSTS) with an average<br />

daily flow of sewage greater than 2,500 gallons and less than or equal to 10,000<br />

gallons. The following attachments may be used to aid in the design and review of the<br />

proposed system.<br />

<strong>Design</strong> <strong>Guidance</strong> <strong>for</strong> <strong>Large</strong> <strong>Subsurface</strong><br />

Minnesota Pollution Control Agency<br />

<strong>Wastewater</strong> Treatment Systems April 2010<br />