24.11.2014 Views

Advance 2007 Atlas - Electronic Ballasts Section - SW Electric ...

Advance 2007 Atlas - Electronic Ballasts Section - SW Electric ...

Advance 2007 Atlas - Electronic Ballasts Section - SW Electric ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

ELECTRONIC<br />

FLUORESCENT<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Contents<br />

General Information .............................................................. 1-2 to 1-25<br />

Compact Fluorescent Lamps ..............................................1-26 to 1-39<br />

CFL<br />

PLH<br />

Long Twin Tubes<br />

2D<br />

Linear Fluorescent Lamps ..................................................1-40 to 1-69<br />

T5<br />

T5 and T5/HO Cirline<br />

T5/HO<br />

T8<br />

T8 Slimline<br />

T8/HO<br />

T10 and T12<br />

T12 Slimline<br />

T12/HO<br />

ELECTRONIC<br />

FLUORESCENT<br />

Note:<br />

Refer to pages 8-14 to 8-30 for Ballast Specifications<br />

Corporate Offices<br />

(800) 322-2086<br />

Customer Support/Technical Service<br />

(800) 372-3331 • (+) 1 847 390-5000 (International)<br />

Visit our web site at www.advancetransformer.com<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-1


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Standard <strong>Electronic</strong><br />

ELECTRONIC<br />

FLUORESCENT<br />

For T8 and T12 Instant or Rapid Start Fluorescent Lamps and for 39 Watt, 40 Watt,<br />

and 50 Watt T5 Rapid Start Long Twin Tube Lamps<br />

Reliable and energy-efficient, <strong>Advance</strong>'s broad line of standard electronic ballasts for T8, T12,<br />

and T5 fluorescent lamps offers proven performance and fast payback of investment based on the<br />

up to 40% energy savings they drive relative to standard magnetic ballast models. A widely popular<br />

product that also qualifies for rebates by a host of utility demand-side management programs<br />

nationwide, <strong>Advance</strong>'s line of standard electronic ballasts are ideal for a broad range of commercial<br />

retrofit and new construction applications.<br />

<strong>Advance</strong>'s standard electronic ballasts are ideal for general office applications as well as<br />

conference, meeting, and board rooms.<br />

Features<br />

Energy-efficient design<br />

Operates up to 75% quieter than<br />

conventional magnetic ballasts<br />

High frequency operation<br />

Fits the exact footprint of the magnetic<br />

ballasts they replace<br />

Backed by 5-year warranty<br />

Benefits<br />

Reduces lighting costs by up to 20% when installed<br />

with modern, energy-efficient lamps in building retrofits<br />

Enhances design flexibility and user satisfaction<br />

Delivers flicker-free operation<br />

Enhances ease of installation in retrofit applications<br />

Insures customer security and satisfaction<br />

1-2<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Centium ®<br />

Standard or Small Can for T8 and T12 Instant or Rapid Start Fluorescent Lamps<br />

and Micro Can for T8 and T5 Instant Start Fluorescent Lamps<br />

Reliable and energy-efficient, <strong>Advance</strong>'s broad line of Centium high frequency electronic ballasts<br />

for T8 and T12 fluorescent lamps offers all of the energy-saving properties of <strong>Advance</strong>'s standard<br />

electronic line plus the added benefits of extended life and small can size options for enhanced<br />

flexibility and versatility. Possessing the same wiring configuration and mounting dimensions as<br />

standard size ballasts, <strong>Advance</strong>'s Centium line is an optimal choice for a broad range of new construction<br />

and retrofit applications within the commercial sector.<br />

ELECTRONIC<br />

FLUORESCENT<br />

Centium is ideal for general office lighting, conference, meeting, and board room applications,<br />

indirect and decorative lighting, and new fixture designs requiring smaller ballasts.<br />

Features<br />

Energy-efficient design<br />

Many instant start models feature IntelliVolt<br />

multiple-voltage technology (enabling<br />

operation from 120 to 277 volts, 50/60Hz<br />

with sustained variation of +/-10%)<br />

Specialized electronic circuitry<br />

High frequency operation<br />

Backed by 5-year warranty<br />

Benefits<br />

Reduces lighting costs by up to 20% when installed<br />

with modern, energy-efficient lamps in building retrofits<br />

Enhances accuracy of ordering and reduces SKU<br />

requirements<br />

Optimizes fit for applications where long lamp life or<br />

frequent switching is required<br />

Provides silent, flicker-free operation<br />

Insures customer security and satisfaction<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-3


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Optanium ®<br />

High-efficiency electronic ballasts for a broad range of T5 and T8 lighting systems<br />

ELECTRONIC<br />

FLUORESCENT<br />

Versatile and high-performing, <strong>Advance</strong>'s Optanium ® high-efficiency electronic ballasts optimize<br />

energy savings and are compatible with T5 high efficiency lamps and the market's wide variety of<br />

T8 fluorescent lamp options -- from standard 32-watt, 40-watt, 25-watt, and 17-watt lamps to 4-<br />

foot energy-saving 30-watt, 28-watt, and 25-watt models -- delivering maximum flexibility and<br />

freedom of choice. Offered in both instant start as well as programmed start options and in<br />

Generation 1.0 (dedicated voltage) and Generation 2.0 (incorporating True Performance<br />

Technology SM and IntelliVolt ® multiple voltage technology) versions.<br />

<strong>Advance</strong>'s Optanium family optimizes lumen-per-watt performance and delivers a high-efficiency<br />

solution for a broad range of commercial, industrial, and institutional applications.<br />

Features<br />

True Performance Technology SM (TPT)<br />

Available in Instant Start and Programmed Start<br />

models to support the market's broad range of<br />

high-efficiency T8 lamp applications<br />

Benefits<br />

<strong>Advance</strong>'s exclusive technology of engineered components<br />

optimizes T8 system performance, resulting in maximum<br />

energy savings, highest lumens-per-watt, and lowest cost of<br />

system ownership<br />

Maximizes flexibility and freedom of choice, regardless of<br />

whether the application involves long burn hours (IS),<br />

frequent switching (PS), or use with occupancy sensors<br />

and/or in frequent on/off areas (PS)<br />

Anti-striation circuitry<br />

Lamp auto-restrike circuitry (Instant Start<br />

Only) and anti-arcing technology<br />

Cold-start capability down to -20°F (on<br />

Optanium 2.0 Instant Start models operating<br />

32-watt lamps only)<br />

PLUS 90 Protection ®<br />

Reduces lamp striation typically seen in energy saving lamps<br />

These and other standard features within the Optanium 2.0<br />

line reduce maintenance concerns and enhance safety<br />

Delivers reliable performance in a wide range of extreme<br />

conditions<br />

<strong>Advance</strong>'s exclusive extended system warranty protection,<br />

which matches any lamp manufacturer's published lampballast<br />

system warranty, plus adds 90 days of additional<br />

warranty protection—on both the lamp and ballast!<br />

1-4<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Mark 5<br />

Programmed Start Integrated Circuit <strong>Electronic</strong> Ballast for 1, 2, and 3 32-Watt,<br />

25-Watt, and 17-Watt T8 Fluorescent Lamps<br />

Designed for easy installation in new construction and retrofit settings, <strong>Advance</strong>'s new and<br />

improved Mark 5 Programmed Start ballasts for 1, 2, and 3 32-Watt, 25-Watt, and 17-Watt T8<br />

fluorescent lamps offer a wide range of features for specialized lighting applications. The Mark 5's<br />

unique integrated circuit-based control technology monitors lamp and ballast conditions to insure<br />

optimum lighting system performance.<br />

ELECTRONIC<br />

FLUORESCENT<br />

Mark 5 is ideal for a wide variety of new construction and retrofit applications.<br />

Features<br />

Programmed start technology<br />

Total harmonic distortion (THD) below<br />

10% for all lamp combinations in any<br />

application<br />

Custom integrated circuit monitors lamp<br />

and ballast conditions<br />

IntelliVolt ® multiple-voltage technology<br />

(enabling Mark 5's operation at any input<br />

voltage from 90 to 305 volts, 50/60Hz)<br />

Operation above 42 Khz<br />

Benefits<br />

Provides extended lamp life in frequent switching<br />

applications (up to 50,000 starts)<br />

Reduces potential for neutral and line conductor<br />

overheating<br />

Delivers optimal lighting system performance<br />

Enhances accuracy of ordering and reduces SKU<br />

requirements<br />

Reduces potential interference with infrared remote<br />

control systems<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-5


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - SmartMate ®<br />

<strong>Electronic</strong> <strong>Ballasts</strong> for 4-Pin Compact Fluorescent Lamps<br />

ELECTRONIC<br />

FLUORESCENT<br />

Offering maximum versatility, <strong>Advance</strong>'s SmartMate electronic ballasts for 4-pin compact fluorescent<br />

lamps drive a broad range of quad and triple-tube, circline, 2D, and long twin-tube lamps.<br />

Representing an innovative breakthrough in CFL ballast technology, SmartMate's energy-efficient<br />

design, compact and lightweight housing, and user-friendly features make SmartMate an ideal<br />

choice for fixture manufacturers, retrofitters, and MRO replacement.<br />

SmartMate is ideal in such applications as restaurants, reception areas, conference and meeting<br />

rooms, hotel and convention center ballrooms, and houses of worship, as well as in place of<br />

incandescent down-lighting systems.<br />

Features<br />

Color-coded dual-entry connector<br />

Color coded, poke-in terminals<br />

Quik Start models available which start<br />

lamps


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Matchbox<br />

Miniaturized <strong>Electronic</strong> <strong>Ballasts</strong> for 4-pin Compact Fluorescent and T5 Linear Lamps<br />

Packaged in a lightweight, miniature housing relative to standard ballast products, <strong>Advance</strong>'s 120V<br />

Matchbox line of energy-efficient electronic ballasts for T5 linear (8-14W) and 4-Pin Compact<br />

Fluorescent (7-26W) lamps offer the combined benefits of enhanced design flexibility and significant<br />

energy savings (up to 25% energy savings compared to electromagnetic ballasts and up to<br />

75% savings over incandescent systems).<br />

ELECTRONIC<br />

FLUORESCENT<br />

Matchbox is ideal in undercabinet, task, ambient, and sign lighting applications as well as in halls<br />

and staircases. Matchbox ballasts meet the Energy Star residential ballast requirements.<br />

Features<br />

Instant-on feature<br />

Color-coded, poke-in-connectors<br />

<strong>Electronic</strong> design<br />

Class B FCC EMI Rating meets Energy Star<br />

and consumer EMI requirements<br />

End-of-lamp-life protection<br />

Benefits<br />

Provides flicker-free starting<br />

Enhances wiring accuracy and ease of<br />

assembly/installation<br />

Delivers energy savings, low temperature starting<br />

(0° F), improved lamp life over 2-pin models, and<br />

no audible noise<br />

Insures approval for use in residential applications<br />

Safely removes power to the lamp(s)<br />

Note; Matchbox ballasts are part of the AmbiStar family<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-7


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - AmbiStar <br />

<strong>Electronic</strong> <strong>Ballasts</strong> for 4-pin Compact Fluorescent and T5, T8 or T12 Linear Lamps<br />

ELECTRONIC<br />

FLUORESCENT<br />

<strong>Advance</strong>'s family of electronic ballasts specifically designed for popular fluorescent applications<br />

in homes and other non-commercial environments brings all of the energy-efficient benefits of<br />

fluorescent lighting to residential and hospitality applications. FCC Class B EMI compliant and<br />

available for T5 linear (8-14W), T8 linear (17-32W), T12 linear (34W-40W) and 4-pin CFL lamps.<br />

<strong>Advance</strong>'s AmbiStar ballasts are compact and lightweight, provide quick starting and save users<br />

significant energy costs relative to alternative lighting sources.<br />

Features<br />

Less than 1.0 second starting<br />

<strong>Electronic</strong> design<br />

Class B FCC EMI Rating meets Energy Star<br />

and consumer EMI requirements<br />

End-of-lamp-life protection for T5 lamps<br />

and smaller<br />

Benefits<br />

Provides flicker-free starting<br />

Increased energy savings over incandescent and<br />

fluorescent magnetic with no audible noise<br />

Insures approval in residential applications<br />

Safely removes power to the lamp(s)<br />

1-8<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - PowrKut ®<br />

Low Frequency <strong>Electronic</strong> <strong>Ballasts</strong> for T8, T10, and T12 Rapid Start Fluorescent Lamps<br />

<strong>Advance</strong>'s PowrKut low frequency electronic ballasts combine the proven performance of electromagnetic<br />

circuitry with the energy savings capabilities of electronics to provide a cost-effective,<br />

energy-efficient solution that offers maximum protection against electromagnetic and radio frequency<br />

interference (EMI/RFI).<br />

ELECTRONIC<br />

FLUORESCENT<br />

<strong>Advance</strong>'s PowrKut ballast is ideal in such applications as office spaces at industrial sites, health<br />

care facilities, consumer electronics retail stores, libraries, educational institutions, radio and<br />

television studios, and in any settings where EMI and/or RFI are a concern.<br />

Features<br />

Unique PowrKut design<br />

Hybrid design with core & coil input<br />

Ability to operate lamps at 60Hz<br />

Open mounting distance for remote or<br />

tandem wiring<br />

Operates T8, T10, and T12 standard and<br />

energy-savings lamps<br />

Benefits<br />

Delivers up to a 26% reduction in energy costs<br />

compared to "standard" electromagnetic ballasts<br />

Protects against transients or voltage surges.<br />

Compatible with powerline carrier systems<br />

Eliminates possible interference with infrared<br />

control systems, radio or television reception, or<br />

portable phone transmission<br />

Provides greater flexibility relative to installation<br />

<strong>Ballasts</strong> are available for more than 90% of<br />

fluorescent applications in the market<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-9


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

ELECTRONIC<br />

FLUORESCENT<br />

<strong>Electronic</strong> Ballast Fundamentals<br />

The job of a ballast<br />

In all fluorescent lighting systems, the ballast’s basic tasks<br />

include:<br />

• Providing the proper voltage to establish an arc between the<br />

two electrodes.<br />

• Regulating the electric current flowing through the lamp to<br />

stabilize light output.<br />

In some fluorescent lighting systems, the ballast also provides<br />

a controlled amount of electrical energy to preheat or maintain the<br />

temperature of the lamp electrodes at levels specified by the manufacturer.<br />

This is required to prevent electrode filaments deteriorating<br />

prematurely and shortening the lamp life.<br />

Starting Methods<br />

For many years there were only three types of lighting systems:<br />

preheat, rapid start and slimline instant start. With the introduction<br />

of electronic ballasts, two additional types of lighting system circuits<br />

have been added: instant start for T8 lamps and programmed<br />

start. Each requires a special ballast design to operate the lamps<br />

in the circuit properly.<br />

Instant start electronic ballasts start lamps without delay (


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Power Factor (PF) is the measurement of how effectively a<br />

ballast converts the voltage and current supplied by the power<br />

source into watts of usable power delivered to the ballast and lamps.<br />

Perfect power utilization would result in a power factor of one.<br />

Input Watts<br />

PF =<br />

Input Current x Input Voltage<br />

A ballast’s power factor may be classified under any one<br />

of the following categories:<br />

High Power Factor (HPF) 0.90 or greater<br />

Power Factor Corrected (PFC) 0.80 to 0.89<br />

Normal (Low) Power Factor (NPF) 0.79 or less<br />

Power factor measurements pertain only to the effective use of<br />

power supplied to the ballast. They are not an indication of the<br />

ballast’s ability to supply light through the lamps. Because low<br />

power factor ballasts require about twice the current needed by<br />

high power factor ballasts, they allow fewer fixtures per circuit and<br />

create added wiring costs. High power factor ballasts are generally<br />

specified for all commercial lighting applications.<br />

EMI/RFI. Because they operate at high frequency, electronic<br />

ballasts may produce electromagnetic interference (EMI) or radio<br />

frequency interference (RFI). RFI frequencies are a subset of EMI<br />

frequencies. EMI issues cover all possible operating frequencies<br />

while RFI is only concerned with radio and television frequencies.<br />

This interference could affect the operation of sensitive electrical<br />

equipment, such as radios, televisions or medical equipment. All<br />

<strong>Advance</strong> electronic ballasts incorporate features necessary<br />

to afford maximum protection for the operating environment and<br />

operate well within regulatory limits. For more information, see<br />

“The ABC’s of <strong>Electronic</strong> Fluorescent <strong>Ballasts</strong>”.<br />

Ballast Noise. The slight “humming” sound associated with<br />

fluorescent lighting systems results from vibration caused by the<br />

inherent electromagnetic action in the core-and-coil assembly of<br />

the ballasts. All electromagnetic and some electronic ballasts make<br />

this sound. <strong>Ballasts</strong> are assigned a sound rating, “A” through “F”,<br />

based on the amount of sound produced, with “A” being the<br />

quietest. Generally, the larger the lamp and ballast, the higher the<br />

sound level and the sound rating will be. Because electronic<br />

ballasts have smaller components, they have the lowest sound<br />

rating. Some electronic ballasts make almost no sound. There is<br />

no ANSI standard for this rating and it is left up to the manufacturer<br />

to rate their ballasts.<br />

Inrush Current. All electrical devices including ballasts have<br />

an initial current surge that is greater than their steady-state<br />

operating current. A new standard published by the National<br />

<strong>Electric</strong>al Manufacturers Association (NEMA) – NEMA 410 –<br />

Performance Testing for Lighting Controls and Switching Devices<br />

with <strong>Electronic</strong> Fluorescent <strong>Ballasts</strong> – covers worst-case ballast<br />

inrush currents. All circuit breakers and light switches are<br />

designed for inrush currents. The electrical system should be<br />

designed with this issue in mind.<br />

Total Harmonic Distortion (THD). Harmonic distortion occurs<br />

when the wave-shape of current or voltage varies from a pure sine<br />

wave. Except for a simple resistor, all electronic devices, including<br />

electromagnetic and electronic ballasts, contribute to power-line<br />

distortion. For ballasts, THD is generally considered the percent<br />

of harmonic current the ballast adds to the power distribution<br />

system. The ANSI standard for electronic ballasts specifies a<br />

maximum THD of 32%. However, most electric utilities now<br />

require that the THD of electronic ballasts be 20% or less. Almost<br />

all <strong>Advance</strong> electronic ballasts are rated for either less than<br />

20% THD or less than 10% THD.<br />

60 Hz Sine<br />

Wave<br />

Actual Waveform<br />

Third Harmonic<br />

(180Hz)<br />

Non-Dimming Applications<br />

Phase A<br />

Phase B<br />

Low Current<br />

Neutral Wire If low Third Harmonic<br />

on balanced system<br />

Phase C<br />

100% Plus Current<br />

Neutral Wire<br />

(Overheated)<br />

Phase A<br />

Phase B<br />

Third<br />

Harmonic<br />

Phase C<br />

When selecting a ballast for a lighting application, the Total<br />

Harmonic Current (THC) rating of the ballast is more significant<br />

than Total Harmonic Distortion (THD). This is because the absolute<br />

value of harmonic current, not the percentage, affects the electrical<br />

power distribution system. As can been seen in the table on page<br />

1-12, the THC rating of our Standard 2-lamp electronic T8 lamp<br />

ballast is well below that of both the conventional and energysaving<br />

magnetic T12 lamp ballasts it replaces. Moreover, the THC<br />

rating of our Centium electronic ballast is even lower.<br />

Dimming Applications<br />

Mark 7 ® 0-10V and ROVR<br />

Traditional low voltage controlled ballasts and ROVR TM typically<br />

produce less than 10% THD at full light output and less than<br />

20% THD throughout the entire dimming range, but require extra<br />

wires for the control circuit. THC is always lower than that of the<br />

conventional or energy-saving magnetic system.<br />

ELECTRONIC<br />

FLUORESCENT<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-11


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

ELECTRONIC<br />

FLUORESCENT<br />

Mark 10 ® Powerline<br />

Mark 10 ® Powerline electronic dimming ballasts are controlled<br />

by 2-wire modified powerline phase-cut style line voltage<br />

dimmers. Whenever the ballast is dimmed, the input voltage is<br />

cut or “chopped”, causing the THD and THC to increase and the<br />

Power Factor to decrease.<br />

Mark 10 ® Powerline electronic dimming systems (ballast and<br />

controller) have similar THD and Power Factor levels as the conventional<br />

lighting systems they replace. Since a much smaller load<br />

is required by the Mark 10 ® Powerline electronic dimming system<br />

to achieve the same illumination level as a magnetic ballast system<br />

(20-30% less), the total input current will be considerably less. As<br />

a result, the magnitude of the total harmonic current will be less.<br />

For example, a typical Mark 10 ® Powerline electronic ballast<br />

and dimmer control might draw a line current of 0.58A at 15%<br />

THD at full light output. If the light level is reduced to 5% of the<br />

maximum, the input power is decreased to 0.19A at 95% THD.<br />

While the THD level may seem alarmingly high at the 5% maximum<br />

light output setting, the total harmonic current is still<br />

lower (0.13A) than the conventional T12 magnetic system<br />

(0.20A). Moreover, the overall heating effect on the wires and<br />

the distribution transformer is never higher than the existing<br />

conventional or energy saving T12 magnetic systems. 1<br />

Conclusions<br />

Our analysis demonstrates that a simple ballast retrofit to<br />

electronic ballasts will not cause harmonic problems if none<br />

existed before the retrofit. Also, in new fixture applications, total<br />

harmonic distortion should not be a concern when specifying<br />

electronic ballasts. Finally, it is important to remember that electronic<br />

ballasts are not the greatest source of THD in an electrical<br />

distribution system. Other electronic devices such as computers,<br />

laser printers, and other electronic equipment can draw<br />

current with more than 100% THD in some cases.<br />

Table 1: Comparison of THD and THC Levels<br />

<strong>Advance</strong><br />

Part No.<br />

Ballast<br />

Type<br />

Light Output<br />

Setting<br />

Lamp<br />

Type<br />

Input<br />

Current<br />

% THD %THC 2<br />

RQM-2S40-TP<br />

Conventional<br />

Magnetic<br />

100% (Ballast<br />

Factor is 0.98)<br />

(2) F40T12 0.84A


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Ballast Life<br />

<strong>Advance</strong> fluorescent electronic and magnetic ballasts are<br />

designed and manufactured to engineering standards correlating to<br />

an average life expectancy of 50,000 hours of operation at maximum<br />

rated case temperature. Since <strong>Advance</strong> ballasts operate<br />

below their maximum case temperature in the majority of applications,<br />

increased ballast life can be expected. As a rule of thumb,<br />

ballast life is doubled for every 10°C reduction in ballast case<br />

operating temperature. However, there are many variables, such as<br />

input voltage, ambient temperature, etc. which affect ballast<br />

operating temperatures, and therefore ballast life.<br />

Lamp Operating Frequency<br />

Electromagnetic ballasts and the lamps connected to them operate<br />

at an input voltage frequency of 60 Hertz (Hz), 60 cycles per<br />

second–which is the standard alternating voltage/current frequency<br />

provided in North America. <strong>Electronic</strong> ballasts, on the other hand,<br />

convert this 60 Hz input to operate lamps at much higher<br />

frequencies above 20 Kilohertz (kHz), 20,000 cycles per second.<br />

<strong>Advance</strong> designs operate above 20 kHz, but avoid certain ranges<br />

such as 30-40 kHz (infrared) and 54-62 kHz (theft deterrent<br />

systems) due to interference issues.<br />

Because electronic ballasts function at high frequency, the fluorescent<br />

lighting systems that they operate can convert power to light<br />

more efficiently than systems operated by electromagnetic ballasts<br />

(See Chart Below). For example, lamps operated on electronic<br />

ballasts can produce over 10 percent more light then if operated on<br />

electromagnetic ballasts at the same power levels. In effect, today’s<br />

electronic ballasts provide additional energy savings by matching<br />

the light output from electromagnetic ballasts while operating the<br />

lamps at lower power. This is the main reason why electronic ballast<br />

systems are more efficient than magnetic ballast system.<br />

Light Output Percentage<br />

114<br />

112<br />

110<br />

108<br />

106<br />

104<br />

102<br />

100<br />

100Hz 1kHz 10kHz 100kHz<br />

Excitation Frequency<br />

Crest Factor<br />

Lamp manufacturers use crest factor to determine ballast<br />

performance as it relates to lamp life. Lamp Current Crest Factor<br />

is a measurement of current supplied by a ballast to start and<br />

operate the lamp. It is basically the ratio of peak current to RMS<br />

(average) current. High crest factor currents may cause the lamp<br />

electrodes to wear out faster, reducing lamp life. Crest factor<br />

requirements are regulated by ANSI (American National Standards<br />

Institute) standards and specified by lamp manufacturers. For<br />

rapid start and instant start T8 lamps the ratio is 1.7 maximum,<br />

and for instant start slimline lamps, it is 1.85 maximum.<br />

Weight and Size Advantages<br />

Since electronic components in electronic ballasts are smaller<br />

and lighter than the core-and-coil assembly in electromagnetic<br />

ballasts, electronic ballasts can weigh less than half as much as<br />

comparable electromagnetic models. Almost all <strong>Advance</strong> electronic<br />

ballasts have a smaller cross-section than electromagnetic ballasts<br />

but maintain the same mounting dimensions. This means that they<br />

can fit into all new fixture designs and can be easily retrofitted into<br />

existing fluorescent lighting systems.<br />

Controllability<br />

The ability of a building’s occupants to control how they light<br />

their space is becoming an increasingly important factor for<br />

organizations in determining what real estate they will lease,<br />

buy or invest in. The ability to dim the lights or easily shut them<br />

off completely is a trend fueled not just by a desire to help the environment,<br />

but also by significant economic benefits. These benefits<br />

include greater energy efficiency – in terms of reduced HVAC costs<br />

as well as energy savings for lighting – more comfortable and<br />

productive working environments, and compliance with ever tighter<br />

energy efficiency regulations. <strong>Advance</strong> offers three families of<br />

electronic controllable ballasts – ROVR , Mark 7 0-10V and<br />

Mark 10 Powerline – that can provide up to 65% energy savings<br />

over standard T8 fixed light output systems.<br />

Compatibility With Powerline Carrier Systems<br />

A powerline carrier system (PLC) uses electronic wiring devices<br />

to send information via a high frequency signal over the 120V or<br />

277V electrical power distribution system of a building. For example,<br />

PLC systems are used in automatic clock systems (master<br />

time systems) to synchronize all of the clocks in a building or reset<br />

the time after a power outage. They eliminate the need for maintenance<br />

personnel to reset hundreds of clocks throughout a facility.<br />

In a PLC system, a generator is used to impose a 1 to 4V high<br />

frequency signal on top of the existing voltage sine wave (60 Hz).<br />

This signal is generally in the 2500 to 9500Hz range, with some<br />

older systems operating at 19,500Hz or higher. Some electronic<br />

ballasts which are capacitive can absorb the signal from a PLC<br />

system. As a result, the signal becomes too weak to be “heard” by<br />

the receiver (like a timeclock) connected to the powerline.<br />

Instant Start vs. Rapid Start Sockets for Dimming<br />

When using dimming ballasts in fixtures, sockets must be of the<br />

RAPID START type. Many fixtures with T-8 Instant Start electronic<br />

ballasts use jumpered or “shunted” Instant Start sockets.<br />

Controllable ballasts require two distinctly separate wires for each<br />

lamp socket. If you encounter shunted or jumpered sockets in a<br />

retrofit application, they must be removed and replaced with Rapid<br />

Start sockets.<br />

Improper socket application will damage the ballast and void the ballast warranty.<br />

Refer to ballast wiring diagram for proper installation.<br />

Rapid Start Sockets<br />

Shunted<br />

SHUNT<br />

Instant Start Sockets<br />

Jumpered<br />

ELECTRONIC<br />

FLUORESCENT<br />

I<br />

Peak<br />

I<br />

Peak<br />

Crest Factor =<br />

I<br />

R.M.S.<br />

I<br />

R.M.S.<br />

Color<br />

‘A’<br />

YES<br />

Color<br />

‘A’<br />

Color<br />

‘A’<br />

NO<br />

Color<br />

‘A’<br />

Fluorescent Lamp Burn-In<br />

Today, most lamp manufacturers do not require the burn-in of linear<br />

fluorescent lamps prior to dimming in order to attain rated lamp<br />

life and stable electrical measurements. However, some manufacturers<br />

compact fluorescent lamp sources do require a 100 hour<br />

burn-in prior to dimming. Consult your lamp manufacturer for their<br />

latest requirements.<br />

NO<br />

NO<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-13


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

ELECTRONIC<br />

FLUORESCENT<br />

ORDERING INFORMATION<br />

How to Order<br />

<strong>Advance</strong> Transformer has developed the industry’s broadest distribution system for<br />

electronic ballasts. More than 3000 stocking distributors nationwide. For information on<br />

the distributor best able to serve your needs, please call 800-372-3331.<br />

<strong>Electronic</strong> Ballast Part Number Breakdown<br />

I CF – 2 S 26 – H1 – LD<br />

CFL Mounting/Connector Options<br />

BS = Bottom mounting studs with single<br />

entry color coded connectors<br />

LD = Length mounting feet with SmartMate<br />

dual entry color coded connectors<br />

LS = Length mounting feet with single<br />

entry color coded connectors<br />

QS = QuikStart<br />

Corporate Offices<br />

(800) 322-2086<br />

Visit our web site at<br />

www.advancetransformer.com<br />

Customer Support/<br />

Technical Service<br />

(800) 372-3331<br />

+1 (847) 390-5000 (International)<br />

Linear Fluorescent Mounting/Connector Options<br />

TP* = Thermal Protected<br />

2LS = 2 Level Switching<br />

CFL Can Desription<br />

H1 = Hybrid metal / plastic case, size 1<br />

L2 = Linear<br />

M1 = Metal case, size 1<br />

M2 = Metal case, size 2<br />

M3 = Metal case, size 3<br />

M4 = Metal case, size 4<br />

M5 = Metal case, size 5<br />

S1 = Square, style 1<br />

S2 = Square, style 2<br />

SC = Small can<br />

Linear Fluorescent Can Desription<br />

90C = 90˚C maximum case temperature rating<br />

D = ‘D’ can<br />

G = ‘G’ can<br />

HL = High light output<br />

LW = Low watt<br />

MC = Micro can<br />

RH* = Reduced harmonics<br />

S = Slimline<br />

SC = Small can<br />

Lamp Watts (Primary lamp)<br />

Maximum Number of Lamps<br />

Family Name<br />

CF = Compact Fluorescent<br />

CN = Centium<br />

DA = ROVR<br />

DL = ROVR<br />

EL = Standard<br />

EZ = Mark 10 ® Powerline<br />

IC = Mark 5 ®<br />

MB = Matchbox<br />

OP = Optanium<br />

ZT = Mark 7 ® 0-10V<br />

Wiring Configuration<br />

D = 2D, series<br />

M = Modified parallel**<br />

P = Parallel<br />

Q = Quad CFL, series<br />

S = Series<br />

T = Triple CFL, series<br />

TTS = Long twin tube, series<br />

TTP = Long twin tube, parallel<br />

• Plan your lighting installation carefully; consider<br />

using the services of a qualified lighting designer<br />

• Consult your local electric utility regarding demand<br />

side management rebate programs.<br />

• Select the <strong>Advance</strong> electronic ballast which best<br />

matches the requirements of your application. The<br />

technical specifications in this catalog (located on<br />

pages 8-4 to 8-22) will be useful in obtaining bids<br />

from electrical contractors.<br />

• Contact your local <strong>Advance</strong> distributor. You will<br />

find them to be a helpful supplier of both products<br />

and information.<br />

Input Voltage<br />

G = 347V<br />

H = IntelliVolt-Hi (347V through 480V, 50/60 Hz)<br />

I = IntelliVolt (120V through 277V, 50/60 Hz)<br />

R = 120V<br />

V = 277V<br />

X = 220V<br />

* Many current and all future electronic ballast part numbers will not use the “RH-TP” suffixes even though these ballasts will be thermally protected.<br />

** Parallel Wiring Configuration. However, if one lamp fails, all other lamps in the circuit will extinguish.<br />

1-14<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

REMOTE, TANDEM OR THROUGH WIRING DISTANCES<br />

REMOTE MOUNTING OF ELECTRONIC BALLASTS<br />

Unlike magnetic ballasts, electronic ballasts are limited in remote mounting distance from the lamps they operate. The factors limiting<br />

the distance from the electronic ballasts to the lamps are: open circuit voltage as opposed to operating voltage, operating frequency and<br />

the lamp operating current.<br />

As the distance from the high frequency electronic ballasts to the lamp increases, so does the capacitance across the lead wire to the<br />

lamp. This increase in capacitance is important for two reasons. First, if the capacitance is too high, there will not be sufficient open<br />

circuit voltage across the lamp for proper lamp ignition.<br />

Second, if the lamp is capable of ignition, the increased capacitance will cause a loss in the current to the lamp. The added capacitance<br />

creates what is known as a “shunt” around the lamp; in other words the current will leak from the red wire (or blue) to the yellow,<br />

completely bypassing the lamp. The current through the lamp will be reduced, resulting in lower lumens, with the possibility that the lamp<br />

will not be capable of sustained operation.<br />

ELECTRONIC<br />

FLUORESCENT<br />

The Mark 7 ® 0-10V, Mark 10 ® Powerline, and ROVR dimming ballasts are particularly sensitive to high capacitance associated with long<br />

lead wires. The dimming ballast is capable of very low dim levels because constant filament heat is provided to the lamp. If there is any<br />

loss of current, the filament current will be reduced and the lamp will begin to flicker, or it will be completely extinguished. It is also<br />

important that the red and blue leads not be twisted together. Twisting the red and blue leads will add capacitance, causing the lamp to<br />

flicker at the lower dimming levels.<br />

Open circuit voltage is a function of input voltage in some ballast designs, particularly for dedicated voltage ballasts. Cold temperature<br />

starting is a function of open circuit voltage. The lead length recommendations in the following table are for normal rated input voltages<br />

(120V, 277V, 347V) at 25°C ambient temperature.<br />

In summary, there is a wide range and varying types of electronic ballast architectures that are capable of being remote mounted for<br />

an equally wide range of distances. If you are uncertain of the remote mounting restrictions for a particular electronic ballast please<br />

consult Technical Services.<br />

Notes:<br />

1. For Tandem or Through wiring, any lamp can be remote mounted.<br />

2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />

3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />

4. No Tandem or Through wiring allowed.<br />

5. No Remote, Tandem or Through wiring allowed.<br />

6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />

7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />

(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />

(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />

(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />

Use 18 AWG wire or larger<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-15


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

ELECTRONIC<br />

FLUORESCENT<br />

Note: Ballast should be mounted<br />

at center of fixture to minimize<br />

lead lengths.<br />

1-16<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

GCN-1S32<br />

GCN-2P32<br />

GCN-2S32<br />

GCN-2TTP40-SC<br />

GCN-3S32<br />

GEL-2P32-LW-RH-TP<br />

GEL-2P32-SC<br />

GEL-2P59<br />

GEL-2S32-RH-TP<br />

GEL-2S40-RH-TP<br />

GEL-3P32-RH-TP<br />

GEL-4P32-LW<br />

GEL-4P32-RH-TP<br />

GK-132-TP (a)<br />

GK-2S32-TP (a)<br />

HCN-2S54-90C<br />

HCN-4S54-90C-2LS-G<br />

ICF-1D38-H1-LD<br />

ICF-1H120-M4-BS<br />

ICF-1H120-M4-LD<br />

ICF-2S13-H1-LD<br />

CF-2S13-M1-BS<br />

ICF-2S13-M1-LS<br />

ICF-2S18-H1-LD<br />

ICF-2S18-M1-BS<br />

ICF-2S18-M1-LS<br />

ICF-2S26-H1-LD<br />

ICF-2S26-M1-BS<br />

ICF-2S26-M1-LS<br />

ICF-2S42-M2-BS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LS<br />

ICF-2S42-90C-M2-BS<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

ICF-2S70-M4-BS<br />

ICF-2S70-M4-LD<br />

Allowed Wiring Configuration<br />

Remote<br />

(max length)<br />

Maximum Lead Length (Feet) for Tandem or Through Wiring<br />

(Total length of all wires between ballast and lamp sockets)<br />

Tandem Through Blue Red Yellow Blue/White Brown Orange<br />

Application<br />

Note<br />

20' NA NA 4<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 4' 20' 20' 2<br />

20' Yes Yes 20' 20' 1<br />

No No No 5<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 4' 20' 3<br />

20' Yes Yes 20' 4' 20' 3<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

20' NA NA 4<br />

20' Yes Yes 4' 20' 20' 2<br />

20' Yes Yes 20' 4' 20' 3<br />

20' Yes Yes 20' 4' 4' 20' 20' 20' 7<br />

15' NA NA 4<br />

1-Lamp 15' NA NA 4<br />

2-Lamp 6' Yes Yes 2' 6' 6' 2<br />

1-Lamp 15' NA NA 4<br />

2-Lamp 6' Yes Yes 2' 6' 6' 2<br />

1-Lamp 15' NA NA 4<br />

2-Lamp 6' Yes Yes 2' 6' 6' 2<br />

1-Lamp 15' NA NA 4<br />

2-Lamp 6' Yes Yes 2' 6' 6' 2<br />

1-Lamp 15' NA NA 4<br />

2-Lamp 6' Yes Yes 2' 6' 6' 2<br />

1-Lamp 15' NA NA 4<br />

2-Lamp 6' Yes Yes 2' 6' 6' 2<br />

6' Yes Yes 2' 6' 6' 2<br />

ELECTRONIC<br />

FLUORESCENT<br />

For nominal input voltage and 25°C ambient temperature.<br />

Notes:<br />

1. For Tandem or Through wiring, any lamp can be remote mounted.<br />

2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />

3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />

4. No Tandem or Through wiring allowed.<br />

5. No Remote, Tandem or Through wiring allowed.<br />

6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />

7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />

(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />

(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />

(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />

Use 18 AWG wire or larger<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-17


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

ELECTRONIC<br />

FLUORESCENT<br />

ICN-132-MC<br />

ICN-1P32-LW-SC<br />

ICN-1P32-SC<br />

ICN-1S80<br />

ICN-2M32-MC<br />

ICN-2P32-LW-SC<br />

ICN-2P32-SC<br />

ICN-2S24<br />

ICN-2S28<br />

ICN-2S39<br />

ICN-2S54<br />

ICN-2S54-90C<br />

ICN-2S86 (b)<br />

ICN-3P32-LW-SC<br />

ICN-3P32-SC<br />

ICN-3S14-D<br />

ICN-4P32-LW-SC<br />

ICN-4P32-SC<br />

ICN-4S54-90C-2LS<br />

ICN-4S54-90C-2LS-G<br />

IDA-132-SC<br />

IDA-154<br />

IDA-2S32-SC<br />

IDA-2S54<br />

IDA-3S32-G<br />

IDA-4S32<br />

IDL-2S26-M5-BS<br />

IDL-2S26-M5-LD<br />

IDL-2T42-M5-BS<br />

IDL-2T42-M5-LD<br />

IEZ-124-D<br />

IEZ-2S24-D<br />

IIC-132-SC<br />

IIC-2S32-SC<br />

IIC-3S32-SC<br />

IOP-1P32-HL-SC<br />

IOP-1P32-LW-SC<br />

IOP-1P32-SC<br />

IOP-1S32-LW-SC (c)<br />

IOP-1S32-SC (c)<br />

IOP-2P32HL-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

Allowed Wiring Configuration<br />

Remote<br />

(max length)<br />

Maximum Lead Length (Feet) for Tandem or Through Wiring<br />

(Total length of all wires between ballast and lamp sockets)<br />

Tandem Through Blue Red Yellow Blue/White Brown Orange<br />

Application<br />

Note<br />

20' NA NA 4<br />

20' NA NA 4<br />

20' NA NA 1<br />

20' NA NA 4<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 4' 20' 3<br />

8' Yes Yes 8' 4' 8' 3<br />

20' Yes Yes 20' 4' 20' 3<br />

20' Yes Yes 20' 4' 20' 3<br />

20' Yes Yes 20' 4' 20' 3<br />

12' Yes Yes 12' 4' 12' 3<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

No No No 5<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 4' 4' 20' 20' 20' 7<br />

20' Yes Yes 20' 4' 4' 20' 20' 20' 7<br />

No NA NA 5<br />

No NA NA 5<br />

No No No 5<br />

No No Yes 5' 4' 4' 5<br />

No No No 5<br />

No No Yes 1' 1.5' 5' 1.5' 4' 5<br />

No No No 5<br />

No No No 5<br />

No NA NA 5<br />

No No Yes 3' 2' 2' 5<br />

20' NA NA 4<br />

20' Yes Yes 4' 20' 20' 2<br />

No No No 5<br />

20' NA NA 4<br />

20' NA NA 4<br />

20' NA NA 4<br />

10' NA NA 4<br />

10' NA NA 4<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

For nominal input voltage and 25°C ambient temperature.<br />

Notes:<br />

1. For Tandem or Through wiring, any lamp can be remote mounted.<br />

2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />

3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />

4. No Tandem or Through wiring allowed.<br />

5. No Remote, Tandem or Through wiring allowed.<br />

6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />

7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />

(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />

(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />

(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />

Use 18 AWG wire or larger<br />

1-18<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

IOP-2P59-SC<br />

IOP-2S32-LW-SC (c)<br />

IOP-2S32-SC (c)<br />

IOP-3P32-HL-90C-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3S32-LW-SC (c)<br />

IOP-3S32-SC (c)<br />

IOP-4P32-HL-90C-G<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4S32-LW-SC (c)<br />

IOP-4S32-SC (c)<br />

IZT-132-SC<br />

IZT-2S26-M5-BS<br />

IZT-2S26-M5-LD<br />

IZT-2S32-SC<br />

IZT-2T42-M3-BS<br />

IZT-2T42-M3-LD<br />

IZT-2T42-M5-BS<br />

IZT-2T42-M5-LD<br />

IZT-2TTS40-SC<br />

IZT-3S32-SC<br />

IZT-4S32<br />

RCF-2S13-H1-LD<br />

RCF-2S13-M1-BS<br />

RCF-2S13-M1-LS<br />

RCF-2S18-H1-LD<br />

RCF-2S18-M1-BS<br />

RCF-2S18-M1-LS<br />

RCF-2S26-H1-LD<br />

RCF-2S26-M1-BS<br />

RCF-2S26-M1-LS<br />

RCN-1S32-SC<br />

RCN-1TTP40-SC<br />

RCN-2P59<br />

RCN-2S32-SC<br />

RCN-2TTP40-SC<br />

RCN-3S32-SC<br />

RCN-3TTP40-SC<br />

RCN-4S32-SC<br />

Allowed Wiring Configuration<br />

Remote<br />

(max length)<br />

Maximum Lead Length (Feet) for Tandem or Through Wiring<br />

(Total length of all wires between ballast and lamp sockets)<br />

Tandem Through Blue Red Yellow Blue/White Brown Orange<br />

20' Yes Yes 20' 20' 1<br />

10' Yes Yes 4' 10' 10' 2<br />

10' Yes Yes 4' 10' 10' 2<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

10' Yes Yes 10' 4' 4' 10' 7<br />

10' Yes Yes 10' 4' 4' 10' 7<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

10' Yes Yes 10' 4' 4' 10' 10' 7<br />

10' Yes Yes 10' 4' 4' 10' 10' 7<br />

6' NA NA 4<br />

No No No 5<br />

6' Yes Yes 6' 6' 6' 1<br />

No No No 5<br />

No No No 5<br />

6' No No 4<br />

No No No 5<br />

No No Yes 1' 1.5' 5' 1.5' 4' 5<br />

1-Lamp 15' No No 4<br />

2-Lamp 6' Yes Yes 2' 6' 6' 2<br />

1-Lamp 15' No No 4<br />

2-Lamp 6' Yes Yes 2' 6' 6' 2<br />

1-Lamp 15' No No 4<br />

Application<br />

Note<br />

2-Lamp 6' Yes Yes 2' 6' 6' 2<br />

20" NA NA 4<br />

20" NA NA 4<br />

20" Yes Yes 20' 20' 1<br />

No Yes Yes 20' 4' 20' 3<br />

20" Yes Yes 20' 20' 1<br />

No Yes Yes 4' 4' 20' 20' 6<br />

20" Yes Yes 20' 20' 1<br />

No Yes Yes 4' 4' 20' 20' 20' 6<br />

ELECTRONIC<br />

FLUORESCENT<br />

For nominal input voltage and 25°C ambient temperature.<br />

Notes:<br />

1. For Tandem or Through wiring, any lamp can be remote mounted.<br />

2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />

3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />

4. No Tandem or Through wiring allowed.<br />

5. No Remote, Tandem or Through wiring allowed.<br />

6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />

7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />

(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />

(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />

(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />

Use 18 AWG wire or larger<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-19


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

ELECTRONIC<br />

FLUORESCENT<br />

REB-2P32-SC<br />

REB-4P32-SC<br />

REL-1P32-HL-SC<br />

REL-1P32-LW-SC<br />

REL-1P32-SC<br />

REL-1S40-SC<br />

REL-1TTS39<br />

REL-1TTS40<br />

REL-1TTS50<br />

REL-2P17-RH-TP<br />

REL-2P32-HL-SC<br />

REL-2P32-LW-SC<br />

REL-2P32-SC<br />

REL-2P59-SC<br />

REL-2P59-S-RH-TP<br />

REL-2P60-S<br />

REL-2S110<br />

REL-2S40-SC<br />

REL-2S86<br />

REL-2TTS39<br />

REL-2TTS40<br />

REL-2TTS50<br />

REL-3P32-HL-SC<br />

REL-3P32-LW-SC<br />

REL-3P32-SC<br />

REL-3S40-RH-TP<br />

REL-4P32-LW-SC<br />

REL-4P32-SC<br />

RELB-2S40-SC<br />

REZ-132-SC<br />

REZ-154<br />

REZ-1Q18-M2-BS<br />

REZ-1Q18-M2-LD<br />

REZ-1T42-M2-BS<br />

REZ-1T42-M2-LD<br />

REZ-1TTS40-SC<br />

REZ-2Q18-M2-BS<br />

REZ-2Q18-M2-LD<br />

REZ-2Q26-M2-BS<br />

REZ-2Q26-M2-LD<br />

REZ-2S32-SC<br />

REZ-2S54<br />

Allowed Wiring Configuration<br />

Remote<br />

(max length)<br />

Maximum Lead Length (Feet) for Tandem or Through Wiring<br />

(Total length of all wires between ballast and lamp sockets)<br />

Tandem Through Blue Red Yellow Blue/White Brown Orange<br />

Application<br />

Note<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 20' 1<br />

20" NA NA 4<br />

20" NA NA 4<br />

20" NA NA 4<br />

20" NA NA 4<br />

No NA NA 5<br />

No NA NA 5<br />

No NA NA 5<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 4' 20' 20' 2<br />

20" Yes Yes 4' 20' 20' 2<br />

20" Yes Yes 4' 20' 20' 2<br />

No No No 5<br />

No No No 5<br />

No No No 5<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

No No No 5<br />

20" Yes Yes 20' 20' 20' 1<br />

20" Yes Yes 20' 20' 20' 1<br />

10" Yes Yes 4' 10' 10' 2<br />

6' NA NA 4<br />

No NA NA 5<br />

No NA NA 5<br />

No NA NA 5<br />

6' NA NA 4<br />

No No No 5<br />

No No No 5<br />

6' Yes No 6' 6' 6' 1<br />

No No Yes 5' 4' 4' 5<br />

For nominal input voltage and 25°C ambient temperature.<br />

Notes:<br />

1. For Tandem or Through wiring, any lamp can be remote mounted.<br />

2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />

3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />

4. No Tandem or Through wiring allowed.<br />

5. No Remote, Tandem or Through wiring allowed.<br />

6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />

7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />

(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />

(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />

(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />

Use 18 AWG wire or larger<br />

1-20<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Allowed Wiring Configuration<br />

Remote<br />

(max length)<br />

Maximum Lead Length (Feet) for Tandem or Through Wiring<br />

(Total length of all wires between ballast and lamp sockets)<br />

Tandem Through Blue Red Yellow Blue/White Brown Orange<br />

Application<br />

Note<br />

REZ-2T42-M3-BS<br />

REZ-2T42-M3-LD<br />

REZ-2TTS40-SC<br />

REZ-3S32-SC<br />

RK-132-TP (a)<br />

RK-2S32-TP (a)<br />

RK-2S34-TP (a)<br />

RMB-1P13-L2<br />

RMB-1P13-S1<br />

RMB-1P13-S2-H<br />

RMB-1P26-S2<br />

RMB-2P13-L2<br />

RMB-2P13-S2<br />

RMB-2P13-S3-H<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

ROP-4P32-HL-90C-G<br />

ROP-4P32-LW-SC<br />

ROP-4P32-SC<br />

RZT-154<br />

RZT-1TTS40<br />

RZT-2S54<br />

VCN-1S32-SC<br />

VCN-1TTP40-SC<br />

VCN-2P59<br />

VCN-2S32-SC<br />

VCN-2TTP40-SC<br />

VCN-3S32-SC<br />

VCN-3TTP40-SC<br />

VCN-4S32-SC<br />

VEL-1P32-HL-SC<br />

VEL-1P32-LW-SC<br />

VEL-1P32-SC<br />

VEL-1S40-SC<br />

VEL-1TTS39<br />

VEL-1TTS40<br />

VEL-1TTS50<br />

VEL-2P17-RH-TP<br />

VEL-2P32-HL-SC<br />

VEL-2P32-LW-SC<br />

No No No 5<br />

6' No No 4<br />

No No No 5<br />

20' NA NA 4<br />

20' Yes Yes 4' 20' 20' 2<br />

20' Yes Yes 4' 20' 20' 2<br />

20' NA NA 4<br />

20' NA NA 4<br />

20' NA NA 4<br />

20' NA NA 4<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

No NA NA 5<br />

6' NA NA 4<br />

No No Yes 5' 4' 4' 5<br />

20" NA NA 4<br />

20" NA NA 4<br />

20" Yes Yes 20' 20' 1<br />

No Yes Yes 20' 4' 20' 3<br />

20" Yes Yes 20' 20' 1<br />

No Yes Yes 4' 4' 20' 20' 6<br />

20" Yes Yes 20' 20' 1<br />

No Yes Yes 4' 4' 20' 20' 20' 6<br />

20" NA NA 4<br />

20" NA NA 4<br />

20" NA NA 4<br />

20" NA NA 4<br />

No NA NA 5<br />

No NA NA 5<br />

No NA NA 5<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

For nominal input voltage and 25°C ambient temperature.<br />

Notes:<br />

1. For Tandem or Through wiring, any lamp can be remote mounted.<br />

2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />

3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />

4. No Tandem or Through wiring allowed.<br />

5. No Remote, Tandem or Through wiring allowed.<br />

6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />

7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />

(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />

(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />

(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />

Use 18 AWG wire or larger<br />

ELECTRONIC<br />

FLUORESCENT<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-21


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

ELECTRONIC<br />

FLUORESCENT<br />

VEL-2P32-SC<br />

VEL-2P59-SC<br />

VEL-2P59S-RH-TP<br />

VEL-2P75-S<br />

VEL-2S110<br />

VEL-2S40-SC<br />

VEL-2S86<br />

VEL-2TTS39<br />

VEL-2TTS40<br />

VEL-2TTS50<br />

VEL-3P32-HL-SC<br />

VEL-3P32-LW-SC<br />

VEL-3P32-SC<br />

VEL-3S40-RH-TP<br />

VEL-4P32-LW-SC<br />

VEL-4P32-SC<br />

VEZ-132-SC<br />

VEZ-154<br />

VEZ-1Q18-M2-BS<br />

VEZ-1Q18-M2-LD<br />

VEZ-1T42-M2-BS<br />

VEZ-1T42-M2-LD<br />

VEZ-1TTS40-SC<br />

VEZ-2Q18-M2-BS<br />

VEZ-2Q18-M2-LD<br />

VEZ-2Q26-M2-BS<br />

VEZ-2Q26-M2-LD<br />

VEZ-2S32-SC<br />

VEZ-2S54<br />

VEZ-2T42-M3-BS<br />

VEZ-2T42-M3-LD<br />

VEZ-2TTS40-SC<br />

VEZ-3S32-SC<br />

VK-132-TP (a)<br />

VK-2S32-TP (a)<br />

VK-2S34-TP (a)<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

VOP-4P32-HL-90C-G<br />

VOP-4P32-LW-SC<br />

VOP-4P32-SC<br />

VZT-154<br />

VZT-180<br />

VZT-1TTS40<br />

VZT-2S54<br />

VZT-4S32-HL<br />

Allowed Wiring Configuration<br />

Remote<br />

(max length)<br />

Maximum Lead Length (Feet) for Tandem or Through Wiring<br />

(Total length of all wires between ballast and lamp sockets)<br />

Tandem Through Blue Red Yellow Blue/White Brown Orange<br />

Application<br />

Note<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 4' 20' 20' 2<br />

20" Yes Yes 4' 20' 20' 2<br />

20" Yes Yes 4' 20' 20' 2<br />

No No No 5<br />

No No No 5<br />

No No No 5<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

20" Yes Yes 20' 20' 1<br />

No No No 5<br />

20" Yes Yes 20' 20' 20' 1<br />

20" Yes Yes 20' 20' 20' 1<br />

6' NA NA 4<br />

No NA NA 5<br />

No NA NA 5<br />

No NA NA 5<br />

6' NA NA 4<br />

No No No 5<br />

No No No 5<br />

6' Yes No 6' 6' 6' 1<br />

No No Yes 5' 4' 4' 5<br />

No No No 5<br />

6' No No 4<br />

No No No 5<br />

20' NA NA 4<br />

20' Yes Yes 4' 20' 20' 2<br />

20' Yes Yes 4' 20' 20' 2<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

20' Yes Yes 20' 20' 20' 1<br />

No NA NA 5<br />

No NA NA 5<br />

6' NA NA 4<br />

No No Yes 5' 4' 4' 5<br />

No No Yes 1' 1.5' 5' 1.5' 4' 5<br />

For nominal input voltage and 25°C ambient temperature.<br />

SEE PAGE 1-21 FOR NOTES<br />

1-22<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Reading Date Codes for Warranty Date on <strong>Electronic</strong> <strong>Ballasts</strong><br />

Most date codes are stamped on the back of the ballast (opposite the label side). The date code is part of a larger group of numbers and<br />

letters, which call out the various codes for the factory where the ballast was manufactured. Depending upon which <strong>Advance</strong> Transformer<br />

factory manufactured the ballast, the date stamp can vary slightly, in terms of its position on the ballast and the number sequence.<br />

Some electronic ballasts manufactured from 1988 to 1991 may have the date code in ink stamped on the ballast label. Some ballasts have<br />

the manufacturing code printed in ink on the end of the ballast.<br />

A typical date code for an electronic ballast will have the week and the year the ballast was manufactured. Some ballasts will have the day<br />

of the week included too.<br />

ADVANCE TRANSFORMER’S ELECTRONIC BALLASTS HAVE A (5) YEAR WARRANTY FROM DATE OF MANUFACTURE, EFFECTIVE WITH<br />

MANUFACTURING IN JANUARY, 1994 (DATE STAMPED 01-94). ELECTRONIC BALLASTS WITH A DATE CODE PRIOR TO THAT DATE, HAVE<br />

A THREE YEAR WARRANTY (DATE STAMPED 52-93 OR EARLIER).<br />

ELECTRONIC<br />

FLUORESCENT<br />

Some examples of these different date codes that you may find are:<br />

937N1B<br />

B41893<br />

The date code is the 18th week of 1993, stamped one line over the other.<br />

This ballast has a (3) year warranty, that ends the 18th week of 1996.<br />

937N1J<br />

P23292<br />

The date code is the 32nd week of 1992, stamped one line over the other.<br />

This ballast has a (3) year warranty, that ends the 32nd week of 1995.<br />

16<br />

93<br />

973N20P3<br />

The date code is the 16th week of 1993, stamped at the end of the ear on the back.<br />

This ballast has a (3) year warranty, that ends the 16th week of 1996.<br />

892P<br />

259P<br />

24<br />

94<br />

The date code is the 4th week of 1994, stamped on four separate lines.<br />

This ballast has a (5) year warranty that ends the 4th week of 1999.<br />

91405BB0291N<br />

The date code is the 2nd week of 1991, stamped on one line.<br />

This ballast has a (3) year warranty that ends the 2nd week of 1994.<br />

9716T032HD<br />

120432IS24<br />

The date code is the 16th week of 1997, stamped in ink on the end of the ballast.<br />

This ballast has a (5) year warranty that ends the 16th week of 2002.<br />

693P0MMA<br />

53397707<br />

The date code is the 5th day, of the 33rd week of 1997, stamped on the back of the ballast.<br />

05127M50<br />

F2104571<br />

The date code is the 127th day of 2005 stamped on the back of the ballast.<br />

FOR ASSISTANCE IN DETERMINING A DATE CODE – CALL TECHNICAL SERVICE AT 1-800-372-3331<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-23


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

SMARTMATE and Mark 10 Powerline Ballast Kits<br />

NOW FEATURING PATENT-PENDING MOUNTING PLATE ADAPTER!<br />

ELECTRONIC<br />

FLUORESCENT<br />

Kit Contents and Key Features<br />

Key Benefits<br />

SmartMate or Mark 10 Powerline ballast<br />

• Intellivolt Technology<br />

• Dual-entry color-coded connectors<br />

• Multi-Lamp Capability<br />

Mounting Plate Adapter<br />

• Multiple lead wire cutouts, including center hole<br />

• Integral mounting studs<br />

Lead Wire<br />

• Color-coded<br />

• Pre-stripped 3/8" on one end – 5/8" on the other<br />

Wire Extraction Tool<br />

Individually Shrink-Wrapped Kits<br />

Makes ballast selection and installation a breeze<br />

• Provides full range input voltage from 120V to 277V<br />

• Adds to application versatility; simplifies wiring<br />

• Encompasses a wide variety of applications, including<br />

• quads, triple tubes, circline, 2D and long twin-tube lamps<br />

Takes the guess-work out of mounting<br />

• Allows wiring and mounting to existing fixture’s mounting plate<br />

• Eliminates need to stock units with and without studs<br />

Allows installer to pre-wire<br />

• Ensures wiring accuracy<br />

• Meets UL poke-in connector requirements and facilitates<br />

• final connection<br />

Makes for quick disconnections if necessary<br />

Provides fast and accurate identification of ballast and lamp<br />

applications<br />

ICF-2S13-H1-LD-K* REZ-2Q26-M2-LD-K* * kits contain the standard<br />

ICF-2S18-H1-LD-K* VEZ-2Q26-M2-LD-K* ballasts. For lamp and operational data<br />

ICF-2S26-H1-LD-K* REZ-1T42-M2-LD-K* consult pages 1-27 through 1-39<br />

ICF-2S42-M2-LD-K* VEZ-1T42-M2-LD-K* and 2-7<br />

• Ideally suited for replacement of expired electronic ballasts, regardless of brand<br />

or mounting configuration.<br />

• Dramatically simplifies the upgrading of incandescent fixtures to energy-saving CFL.<br />

• Compatible with most J-Box covers<br />

1-24<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

NOTES<br />

ELECTRONIC<br />

FLUORESCENT<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-25


T4<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 7 - 9W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

CFT7W/2G7 - 7W CFL Twin Tube Lamp (CF7DS/E)<br />

RMB-1P13-L2<br />

L2<br />

8 1.00 150 0.13<br />

1 120 IS Matchbox † RMB-1P13-S1<br />

0/-18 S1<br />

RMB-1P13-S2-H 8 1.00 25 0.07<br />

S2<br />

RMB-2P13-L2<br />

L2<br />

16 1.10 150 0.24<br />

2 120 IS Matchbox † RMB-2P13-S2<br />

0/-18 S2<br />

RMB-2P13-S3-H 16 1.00 15 0.14<br />

S3<br />

CFT9W/2G7 - 9W CFL Twin Tube Lamp (CF9DS/E)<br />

RMB-1P13-L2<br />

L2<br />

10 1.10 150 0.16<br />

1 120 IS Matchbox † RMB-1P13-S1<br />

0/-18 S1<br />

RMB-1P13-S2-H 10 1.05 20 0.09<br />

S2<br />

RMB-2P13-L2<br />

L2<br />

20 1.10 125 0.29<br />

2 120 IS Matchbox † RMB-2P13-S2<br />

0/-18 S2<br />

RMB-2P13-S3-H 20 1.05 10 0.17<br />

S3<br />

Dim.<br />

Wiring<br />

Dia.<br />

160<br />

159<br />

160<br />

159<br />

† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

S1 Model<br />

S2 Model<br />

L2 Model<br />

S3 Model<br />

1 or 2 lamp linear ballast, plastic enclosure<br />

See page 1-28 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-26<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 13 - 18W Quad Lamps<br />

T4<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

CFQ13W/G24q - 13W CFL Quad Tube Lamp (PL-C13W/4P, F13DBX/4P, CF13DD/E)<br />

RMB-1P13-L2<br />

L2<br />

14 1.00 150 0.20<br />

IS Matchbox † RMB-1P13-S1<br />

S1<br />

120<br />

RMB-1P13-S2-H 14 0.85 20 0.12<br />

S2<br />

RCF-2S13-H1-LD-QS<br />

AmbiStar RCF-2S13-M1-BS-QS 16 1.00 10 0.13<br />

RCF-2S13-M1-LS-QS<br />

QS<br />

1 ICF-2S13-H1-LD-QS<br />

0/-18<br />

ICF-2S13-M1-BS-QS 16 1.00 10 0.13-0.06<br />

ICF-2S13-M1-LS-QS<br />

Size 1<br />

120-277<br />

SmartMate ICF-2S13-H1-LD<br />

PS<br />

ICF-2S13-H1-LD-K ➀<br />

ICF-2S13-M1-BS<br />

16 1.00 10 0.13-0.06<br />

ICF-2S13-M1-LS<br />

RMB-2P13-L2<br />

L2<br />

25 0.95 125 0.35<br />

IS Matchbox † RMB-2P13-S2<br />

S2<br />

120<br />

RMB-2P13-S3-H 27 0.90 10 0.23<br />

S3<br />

RCF-2S13-H1-LD-QS<br />

AmbiStar RCF-2S13-M1-BS-QS 29 1.00 10 0.25<br />

RCF-2S13-M1-LS-QS<br />

QS<br />

2 ICF-2S13-H1-LD-QS<br />

0/-18<br />

ICF-2S13-M1-BS-QS 29 1.00 10 0.25-0.11<br />

ICF-2S13-M1-LS-QS<br />

Size 1<br />

120-277<br />

SmartMate ICF-2S13-H1-LD<br />

PS<br />

ICF-2S13-H1-LD-K ➀<br />

ICF-2S13-M1-BS<br />

29 1.00 10 0.25-0.11<br />

ICF-2S13-M1-LS<br />

CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4 P, F18DBX/4P, CF18DD/E)<br />

RMB-2P13-L2<br />

L2<br />

16 0.80 150 0.26<br />

IS Matchbox † RMB-2P13-S2<br />

S2 *159<br />

120<br />

RMB-2P13-S3-H 15 0.80 15 0.13<br />

S3<br />

RCF-2S18-H1-LD-QS<br />

AmbiStar RCF-2S18-M1-BS-QS 19 1.00 10 0.16<br />

RCF-2S18-M1-LS-QS<br />

QS<br />

1 ICF-2S18-H1-LD-QS<br />

0/-18<br />

ICF-2S18-M1-BS-QS 19 1.00 10 0.16-0.07<br />

ICF-2S18-M1-LS-QS<br />

Size 1 160<br />

120-277<br />

SmartMate ICF-2S18-H1-LD<br />

PS<br />

ICF-2S18-H1-LD-K ➀<br />

ICF-2S18-M1-BS<br />

19 1.00 10 0.16-0.07<br />

ICF-2S18-M1-LS<br />

RCF-2S18-H1-LD-QS<br />

120<br />

AmbiStar RCF-2S18-M1-BS-QS 35 0.95 10 0.30<br />

QS<br />

RCF-2S18-M1-LS-QS<br />

ICF-2S18-H1-LD-QS<br />

2<br />

ICF-2S18-M1-BS-QS 35 0.95 10 0.30-0.13<br />

ICF-2S18-M1-LS-QS<br />

0/-18 Size 1 159<br />

120-277<br />

SmartMate ICF-2S18-H1-LD<br />

PS<br />

ICF-2S18-H1-LD-K ➀<br />

ICF-2S18-M1-BS<br />

ICF-2S18-M1-LS<br />

35 0.95 10 0.30-0.13<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

160<br />

159<br />

ELECTRONIC<br />

FLUORESCENT<br />

HIGH FREQUENCY<br />

ELECTRONIC<br />

†<br />

Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

See page 1-26 for Dimensions<br />

See page 1-28 for Wiring Diagrams<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-27


T4<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 26W Quad Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E)<br />

IS Matchbox † RMB-1P26-S2<br />

26 0.95 125 0.38<br />

S2<br />

120<br />

RCF-2S26-H1-LD-QS<br />

AmbiStar RCF-2S26-M1-BS-QS 27 1.00 10 0.23<br />

QS<br />

RCF-2S26-M1-LS-QS<br />

ICF-2S26-H1-LD-QS<br />

1 ICF-2S26-M1-BS-QS 27 1.00 10 0.23-0.10 0/-18<br />

ICF-2S26-M1-LS-QS<br />

Size 1<br />

120-277<br />

SmartMate ICF-2S26-H1-LD<br />

PS<br />

ICF-2S26-H1-LD-K ➀<br />

ICF-2S26-M1-BS<br />

27 1.00 10 0.23-0.10<br />

ICF-2S26-M1-LS<br />

RCF-2S26-H1-LD-QS<br />

120<br />

AmbiStar RCF-2S26-M1-BS-QS 51 1.00 10 0.43<br />

QS<br />

RCF-2S26-M1-LS-QS<br />

ICF-2S26-H1-LD-QS<br />

ICF-2S26-M1-BS-QS 51 1.00 10 0.43-0.19<br />

ICF-2S26-M1-LS-QS<br />

Size 1<br />

ICF-2S26-H1-LD<br />

ICF-2S26-H1-LD-K ➀<br />

51 1.00 10 0.43-0.19<br />

2 ICF-2S26-M1-BS<br />

0/-18<br />

120-277<br />

SmartMate<br />

ICF-2S26-M1-LS<br />

ICF-2S42-M2-BS<br />

PS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LD-K ➀<br />

52 1.00 10 0.43-0.19<br />

ICF-2S42-M2-LS<br />

Size 2<br />

ICF-2S42-90C-M2-BS<br />

ICF-2S42-90C-M2-LD 52 1.00 10 0.43-0.19<br />

ICF-2S42-90C-M2-LS<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

160<br />

159<br />

† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors<br />

See page 1-26 for Dimensions<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-28<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 13W Triple Lamps<br />

T4<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

CFTR13W/GX24q - 13W CFL Triple Tube Lamp (F13TBX/4P, CF13DT/E)<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

RMB-1P13-L2<br />

L2<br />

14 1.00 150 0.20<br />

IS Matchbox † RMB-1P13-S1<br />

S1<br />

120<br />

RMB-1P13-S2-H 14 0.85 20 0.12<br />

S2<br />

RCF-2S13-H1-LD-QS<br />

AmbiStar RCF-2S13-M1-BS-QS 16 1.00 10 0.13<br />

RCF-2S13-M1-LS-QS<br />

QS<br />

1 ICF-2S13-H1-LD-QS<br />

0/-18<br />

ICF-2S13-M1-BS-QS 16 1.00 10 0.13-0.06<br />

ICF-2S13-M1-LS-QS<br />

Size 1<br />

120-277<br />

SmartMate ICF-2S13-H1-LD<br />

PS<br />

ICF-2S13-H1-LD-K ➀<br />

ICF-2S13-M1-BS<br />

16 1.00 10 0.13-0.06<br />

ICF-2S13-M1-LS<br />

RMB-2P13-L2<br />

L2<br />

25 0.95 125 0.35<br />

IS Matchbox † RMB-2P13-S2<br />

S2<br />

120<br />

RMB-2P13-S3-H 27 0.90 10 0.23<br />

S3<br />

RCF-2S13-H1-LD-QS<br />

AmbiStar RCF-2S13-M1-BS-QS 29 1.00 10 0.25<br />

RCF-2S13-M1-LS-QS<br />

QS<br />

2 ICF-2S13-H1-LD-QS<br />

0/-18<br />

ICF-2S13-M1-BS-QS 29 1.00 10 0.25-0.11<br />

ICF-2S13-M1-LS-QS<br />

Size 1<br />

120-277<br />

SmartMate ICF-2S13-H1-LD<br />

PS<br />

ICF-2S13-H1-LD-K ➀<br />

ICF-2S13-M1-BS<br />

29 1.00 10 0.25-0.11<br />

ICF-2S13-M1-LS<br />

† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

Max.<br />

THD<br />

%<br />

Dim.<br />

Wiring<br />

Dia.<br />

160<br />

159<br />

ELECTRONIC<br />

FLUORESCENT<br />

* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors 1-29<br />

See page 1-26 for Dimensions<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


T4<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 18W Triple Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W/4P, F18TBX/4P, CF18DT/E)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

RMB-2P13-L2<br />

L2<br />

16 0.80 150 0.26<br />

IS Matchbox † RMB-2P13-S2<br />

S2 *159<br />

120<br />

RMB-2P13-S3-H 15 0.80 15 0.13<br />

S3<br />

RCF-2S18-H1-LD-QS<br />

AmbiStar RCF-2S18-M1-BS-QS 20 1.05 10 0.17<br />

RCF-2S18-M1-LS-QS<br />

QS<br />

1 ICF-2S18-H1-LD-QS<br />

0/-18<br />

ICF-2S18-M1-BS-QS 20 1.05 10 0.17-0.08<br />

ICF-2S18-M1-LS-QS<br />

Size 1 160<br />

120-277<br />

SmartMate ICF-2S18-H1-LD<br />

PS<br />

ICF-2S18-H1-LD-K ➀<br />

ICF-2S18-M1-BS<br />

20 1.05 10 0.17-0.08<br />

ICF-2S18-M1-LS<br />

RCF-2S18-H1-LD-QS<br />

120<br />

AmbiStar RCF-2S18-M1-BS-QS 39 1.05 10 0.33<br />

QS<br />

RCF-2S18-M1-LS-QS<br />

ICF-2S18-H1-LD-QS<br />

2<br />

ICF-2S18-M1-BS-QS 39 1.05 10 0.33-0.14<br />

ICF-2S18-M1-LS-QS<br />

0/-18 Size 1 159<br />

120-277<br />

SmartMate ICF-2S18-H1-LD<br />

PS<br />

ICF-2S18-H1-LD-K ➀<br />

ICF-2S18-M1-BS<br />

ICF-2S18-M1-LS<br />

39 1.05 10 0.33-0.14<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Dim.<br />

Wiring<br />

Dia.<br />

† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors<br />

See page 1-26 for Dimensions<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-30<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 26 - 32W Triple Lamps<br />

T4<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W/4P, F26TBX/4P, CF26DT/E)<br />

IS Matchbox † RMB-1P26-S2<br />

26 0.95 125 0.38<br />

S2<br />

120<br />

RCF-2S26-H1-LD-QS<br />

AmbiStar RCF-2S26-M1-BS-QS 29 1.10 10 0.24<br />

RCF-2S26-M1-LS-QS<br />

QS<br />

ICF-2S26-H1-LD-QS<br />

0/-18<br />

Size 1<br />

1<br />

ICF-2S26-M1-BS-QS 29 1.10 10 0.24-0.11<br />

ICF-2S26-M1-LS-QS<br />

120-277<br />

SmartMate ICF-2S26-H1-LD<br />

PS<br />

ICF-2S26-H1-LD-K ➀<br />

ICF-2S26-M1-BS<br />

29 1.10 10 0.24-0.11<br />

ICF-2S26-M1-LS<br />

RCF-2S26-H1-LD-QS<br />

120<br />

AmbiStar RCF-2S26-M1-BS-QS 54 1.00 10 0.45<br />

QS<br />

RCF-2S26-M1-LS-QS<br />

ICF-2S26-H1-LD-QS<br />

ICF-2S26-M1-BS-QS 54 1.00 10 0.45-0.20<br />

ICF-2S26-M1-LS-QS<br />

Size 1<br />

ICF-2S26-H1-LD<br />

ICF-2S26-H1-LD-K ➀<br />

54 1.00 10 0.45-0.20<br />

2<br />

ICF-2S26-M1-BS<br />

0/-18<br />

120-277<br />

SmartMate<br />

ICF-2S26-M1-LS<br />

ICF-2S42-M2-BS<br />

PS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LD-K ➀<br />

55 1.00 10 0.46-0.21<br />

ICF-2S42-M2-LS<br />

Size 2<br />

ICF-2S42-90C-M2-BS<br />

ICF-2S42-90C-M2-LD 55 1.00 10 0.46-0.21<br />

ICF-2S42-90C-M2-LS<br />

CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W/4P, F32TBX/4P, CF32DT/E)<br />

1<br />

2<br />

Input<br />

Volts<br />

120<br />

120-277<br />

277<br />

Lamp<br />

Starting<br />

Method<br />

QS<br />

PS<br />

PS<br />

Ballast<br />

Family<br />

AmbiStar<br />

SmartMate<br />

SmartMate<br />

Catalog Number<br />

RCF-2S26-H1-LD-QS<br />

RCF-2S26-M1-BS-QS<br />

RCF-2S26-M1-LS-QS<br />

ICF-2S26-H1-LD-QS<br />

ICF-2S26-M1-BS-QS<br />

ICF-2S26-M1-LS-QS<br />

ICF-2S26-H1-LD<br />

ICF-2S26-H1-LD-K ➀<br />

ICF-2S26-M1-BS<br />

ICF-2S26-M1-LS<br />

ICF-2S42-M2-BS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LD-K ➀<br />

ICF-2S42-M2-LS<br />

ICF-2S42-90C-M2-BS<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

36<br />

36<br />

36<br />

68<br />

68<br />

Ballast<br />

Factor<br />

0.98<br />

0.98<br />

0.98<br />

0.98<br />

0.98<br />

Max.<br />

THD<br />

%<br />

10<br />

10<br />

10<br />

10<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.31<br />

0.31-0.13<br />

0.31-0.13<br />

0.57-0.25<br />

0.57-0.25<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

0/-18<br />

Dim.<br />

Size 1<br />

Size 2<br />

Wiring<br />

Dia.<br />

160<br />

159<br />

160<br />

159<br />

ELECTRONIC<br />

FLUORESCENT<br />

† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

See page 1-26 for Dimensions<br />

See page 1-28 for Wiring Diagrams<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-31


T4<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 42 - 70W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W/4P, F42TBX/4P, CF42DT/E)<br />

RCF-2S26-H1-LD-QS<br />

120<br />

AmbiStar RCF-2S26-M1-BS-QS 46 0.98 10 0.38<br />

QS<br />

RCF-2S26-M1-LS-QS<br />

ICF-2S26-H1-LD-QS<br />

1<br />

ICF-2S26-M1-BS-QS 46 0.98 10 0.38-0.17<br />

ICF-2S26-M1-LS-QS<br />

0/-18 Size 1 160<br />

120-277<br />

SmartMate ICF-2S26-H1-LD<br />

PS<br />

ICF-2S26-H1-LD-K ➀<br />

ICF-2S26-M1-BS<br />

ICF-2S26-M1-LS<br />

ICF-2S42-M2-BS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LD-K ➀<br />

46<br />

93<br />

0.98<br />

0.97<br />

10<br />

10<br />

0.38-0.17<br />

0.78-0.33<br />

2 120-277 PS SmartMate ICF-2S42-M2-LS<br />

ICF-2S42-90C-M2-BS<br />

0/-18 Size 2 159<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

93 0.97 10 0.78-0.33<br />

CFTR57W/GX24q - 57W CFL Lamp (F57QBX/4P, CF57DT/E)<br />

ICF-2S42-M2-BS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LD-K ➀<br />

59 0.94 10 0.80-0.21<br />

1 120-277 PS SmartMate ICF-2S42-M2-LS<br />

ICF-2S42-90C-M2-BS<br />

14/-10 Size 1 160<br />

2 120-277 PS SmartMate<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

ICF-2S70-M4-BS<br />

ICF-2S70-M4-LD<br />

59<br />

128-126<br />

0.94<br />

1.00<br />

10<br />

10<br />

0.80-0.21<br />

1.07-0.46 0/-18 Size 4 159<br />

CFTR70W/GX24q - 70W CFL Lamp (F70QBX/4P)<br />

ICF-2S42-M2-BS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LD-K ➀<br />

75 0.96 10 0.63-0.27<br />

1 120-277 PS SmartMate ICF-2S42-M2-LS<br />

ICF-2S42-90C-M2-BS<br />

14/-10 Size 2 160<br />

2 120-277 PS SmartMate<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

ICF-2S70-M4-BS<br />

ICF-2S70-M4-LD<br />

75<br />

156-152<br />

0.96<br />

1.00<br />

10<br />

10<br />

0.63-0.27<br />

1.30-0.56 0/-18 Size 4 159<br />

Max.<br />

THD<br />

%<br />

Dim.<br />

Wiring<br />

Dia.<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

See page 1-33 for Dimensions and Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-32<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 60 - 120W Lamps<br />

T4<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

1<br />

2<br />

Input<br />

Volts<br />

120-277<br />

120-277<br />

Lamp<br />

Starting<br />

Method<br />

60W PLH (PL-H60W/4P)<br />

PS<br />

PS<br />

Ballast<br />

Family<br />

SmartMate<br />

Catalog Number<br />

ICF-1H120-M4-BS<br />

ICF-1H120-M4-LD<br />

ICF-1H120-M4-BS<br />

ICF-1H120-M4-LD<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

70<br />

139-136<br />

Ballast<br />

Factor<br />

1.00<br />

1.00<br />

Max.<br />

THD<br />

%<br />

15<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.59-0.26<br />

1.16-0.50<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

-22/-30<br />

-22/-30<br />

Dim.<br />

Size 4<br />

Size 4<br />

Wiring<br />

Dia.<br />

160<br />

159<br />

ELECTRONIC<br />

FLUORESCENT<br />

85W PLH (PL-H85W/4P)<br />

1<br />

120-277<br />

PS<br />

SmartMate<br />

ICF-1H120-M4-BS<br />

ICF-1H120-M4-LD<br />

98-97<br />

1.00<br />

10<br />

0.82-0.36<br />

-22/-30<br />

Size 4<br />

160<br />

120W PLH (PL-H120W/4P)<br />

1<br />

120-277<br />

PS<br />

SmartMate<br />

ICF-1H120-M4-BS<br />

ICF-1H120-M4-LD<br />

139-136<br />

1.00<br />

10<br />

1.16-0.50<br />

-22/-30<br />

Size 4<br />

160<br />

* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-33


FT5<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 18 - 36W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

FT18W/2G11/RS - 18W (F18BX/RS, FT18DL/RS)<br />

1 120 IS Matchbox † RMB-1P26-S2<br />

23 1.00 150 0.37 0/-18 S2 160<br />

FT24W/2G11 - 24/27W (PL-L24W, F27BX/RS, FT24DL)<br />

120 IS Matchbox † RMB-1P26-S2<br />

26 0.95 150 0.40<br />

S2 160<br />

1<br />

ICN-2S24<br />

27 1.02 10 0.23-0.10 0/-18<br />

120-277 PS Centium<br />

ICN-2S39<br />

29 1.12 15 0.24-0.12<br />

ICF-2S26-H1-LD<br />

D 73<br />

ICF-2S26-H1-LD-K ➀<br />

ICF-2S26-M1-BS<br />

ICF-2S26-M1-LS<br />

ICF-2S42-M2-BS<br />

48 0.93 10 0.41-0.18<br />

Size 1 160<br />

SmartMate ICF-2S42-M2-LD<br />

2 120-277 PS<br />

ICF-2S42-M2-LD-K ➀<br />

0/-18<br />

ICF-2S42-M2-LS<br />

ICF-2S42-90C-M2-BS<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

48 0.93 15 0.40-0.18<br />

Size 2 159<br />

Centium<br />

ICN-2S24<br />

52 1.00 10 0.44-0.19<br />

ICN-2S39<br />

54 1.10 10 0.46-0.20<br />

D 74<br />

FT36W/2G11 - 36/39W (PL-L36W, F39BX/RS, FT36DL)<br />

1<br />

2<br />

3<br />

4<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347-480<br />

120<br />

277<br />

120-277<br />

347-480<br />

120-277<br />

347-480<br />

120-277<br />

347-480<br />

Lamp<br />

Starting<br />

Method<br />

RS<br />

PS<br />

RS<br />

PS<br />

PS<br />

PS<br />

Ballast<br />

Family<br />

Standard<br />

Centium<br />

Standard<br />

Centium<br />

Centium<br />

Centium<br />

Catalog Number<br />

REL-1TTS39<br />

VEL-1TTS39<br />

ICN-2S24<br />

ICN-2S39<br />

ICN-2S54<br />

ICN-2S54-90C<br />

HCN-2S54-90C<br />

REL-2TTS39<br />

VEL-2TTS39<br />

ICN-2S39<br />

ICN-2S54<br />

ICN-2S54-90C<br />

HCN-2S54-90C<br />

ICN-4S54-90C-2LS<br />

ICN-4S54-90C-2LS-G<br />

HCN-4S54-90C-2LS-G<br />

ICN-4S54-90C-2LS<br />

ICN-4S54-90C-2LS<br />

HCN-4S54-90C-2LS-G<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

39<br />

34<br />

36<br />

46<br />

46<br />

70<br />

69<br />

89-86<br />

89<br />

133-132<br />

137-135<br />

176-173<br />

182-180<br />

Ballast<br />

Factor<br />

1.00<br />

0.90<br />

0.96<br />

1.22<br />

1.22<br />

0.85<br />

0.94<br />

1.20<br />

1.20<br />

1.20<br />

1.20<br />

1.20<br />

1.20<br />

Max.<br />

THD<br />

%<br />

20<br />

10<br />

15<br />

20<br />

15<br />

20<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.35<br />

0.15<br />

0.29-0.13<br />

0.30-0.13<br />

0.39-0.18<br />

0.13-0.10<br />

0.59<br />

0.25<br />

0.59-0.25<br />

0.75-0.32<br />

0.26-0.19<br />

1.11-0.49<br />

0.40-0.29<br />

1.47-0.64<br />

0.53-0.38<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

50/10<br />

0/-18<br />

50/10<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

A<br />

D<br />

A<br />

D<br />

E<br />

G<br />

E<br />

G<br />

Wiring<br />

Dia.<br />

93<br />

73<br />

94<br />

74<br />

*75<br />

75<br />

† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

See page 1-36 for Dimensions<br />

See page 1-37 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-34<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 40W Lamps<br />

FT5<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

FT40W/2G11/RS - 40W (PL-L40W, F40/30BX, FT40DL/RS)<br />

RS Standard REL-1TTS40<br />

120<br />

RCN-1TTP40-SC<br />

IS Centium<br />

RCN-2TTP40-SC<br />

RS Standard VEL-1TTS40<br />

277<br />

VCN-1TTP40-SC<br />

IS<br />

VCN-2TTP40-SC<br />

Centium<br />

ICN-2S24<br />

1<br />

ICN-2S39<br />

ICF-2S42-M2-BS<br />

120-277 PS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LD-K ➀<br />

SmartMate ICF-2S42-M2-LS<br />

347 IS<br />

RS<br />

Centium<br />

Standard<br />

ICF-2S42-90C-M2-BS<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

GCN-2TTP40-SC<br />

REL-2TTS40<br />

120<br />

RCN-2TTP40-SC<br />

IS Centium<br />

RCN-3TTP40-SC<br />

RS Standard VEL-2TTS40<br />

277<br />

VCN-2TTP40-SC<br />

IS Centium<br />

VCN-3TTP40-SC<br />

2<br />

ICF-2S42-M2-BS<br />

ICF-2S42-M2-LD<br />

120-277<br />

347<br />

PS<br />

IS<br />

SmartMate<br />

Centium<br />

ICF-2S42-M2-LD-K ➀<br />

ICF-2S42-M2-LS<br />

ICF-2S42-90C-M2-BS<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

GCN-2TTP40-SC<br />

3<br />

120<br />

RCN-3TTP40-SC<br />

IS Centium<br />

277<br />

VCN-3TTP40-SC<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

44<br />

41<br />

44<br />

44<br />

41<br />

44<br />

47<br />

50<br />

44<br />

42<br />

71<br />

72<br />

78<br />

71<br />

72<br />

78<br />

78<br />

78<br />

65<br />

103<br />

Ballast<br />

Factor<br />

1.00<br />

0.90<br />

1.00<br />

1.00<br />

0.90<br />

0.97<br />

1.00<br />

1.10<br />

0.95<br />

1.04<br />

0.85<br />

0.88<br />

0.97<br />

0.85<br />

0.88<br />

0.95<br />

0.95<br />

0.95<br />

0.88<br />

0.86<br />

Max.<br />

THD<br />

%<br />

20<br />

10<br />

10<br />

20<br />

10<br />

15<br />

10<br />

10<br />

10<br />

44 0.95 10<br />

10<br />

20<br />

10<br />

10<br />

20<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.37<br />

0.35<br />

0.38<br />

0.16<br />

0.16<br />

0.16<br />

0.40-0.17<br />

0.42-0.19<br />

0.37-0.16<br />

0.37-0.16<br />

0.13<br />

0.60<br />

0.62<br />

0.66<br />

0.26<br />

0.26<br />

0.28<br />

0.66-0.28<br />

0.66-0.28<br />

0.19<br />

0.88<br />

0.37<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

50/10<br />

0/-18<br />

50/10<br />

0/-18<br />

50/10<br />

0/-18<br />

50/10<br />

0/-18<br />

0/-18<br />

Dim.<br />

A<br />

B<br />

A<br />

B<br />

D<br />

Size 2<br />

B<br />

A<br />

B<br />

A<br />

B<br />

Size 2<br />

B<br />

B<br />

Wiring<br />

Dia.<br />

93<br />

70<br />

93<br />

70<br />

73<br />

160<br />

70<br />

94<br />

71<br />

94<br />

71<br />

159<br />

71<br />

72<br />

ELECTRONIC<br />

FLUORESCENT<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

See page 1-36 for Dimensions<br />

See page 1-37 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-35


FT5<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 50W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

1<br />

2<br />

3<br />

4<br />

Input<br />

Volts<br />

FT50W/2G11/RS - 50W (PL-L50W, F50BX/RS)<br />

120<br />

RS Standard<br />

277<br />

120-277<br />

347-480<br />

120<br />

277<br />

120-277<br />

347-480<br />

120-277<br />

347-480<br />

120-277<br />

347-480<br />

Lamp<br />

Starting<br />

Method<br />

PS<br />

RS<br />

PS<br />

PS<br />

PS<br />

Ballast<br />

Family<br />

Centium<br />

Standard<br />

Centium<br />

Centium<br />

Centium<br />

Catalog Number<br />

REL-1TTS50<br />

VEL-1TTS50<br />

ICN-2S54<br />

ICN-2S54-90C<br />

HCN-2S54-90C<br />

REL-2TTS50<br />

VEL-2TTS50<br />

ICN-2S54<br />

ICN-2S54-90C<br />

HCN-2S54-90C<br />

ICN-4S54-90C-2LS<br />

ICN-4S54-90C-2LS-G<br />

HCN-4S54-90C-2LS-G<br />

ICN-4S54-90C-2LS<br />

ICN-4S54-90C-2LS<br />

HCN-4S54-90C-2LS-G<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

54<br />

61<br />

61<br />

106<br />

118-115<br />

118<br />

178-175<br />

185-183<br />

235-230<br />

236-234<br />

Ballast<br />

Factor<br />

0.98<br />

1.12<br />

1.12<br />

0.98<br />

1.10<br />

1.10<br />

1.10<br />

1.10<br />

1.10<br />

1.10<br />

Max.<br />

THD<br />

%<br />

20<br />

15<br />

10<br />

20<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.46<br />

0.20<br />

0.51-0.23<br />

0.18-0.13<br />

0.90<br />

0.39<br />

0.99-0.43<br />

0.34-0.25<br />

1.49-0.65<br />

0.54-0.39<br />

1.96-0.84<br />

0.68-0.49<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

50/10<br />

0/-18<br />

50/10<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

A<br />

D<br />

A<br />

D<br />

E<br />

G<br />

E<br />

G<br />

Wiring<br />

Dia.<br />

93<br />

73<br />

94<br />

74<br />

*75<br />

75<br />

Fig. A<br />

1.18"<br />

8.90"<br />

9.5"<br />

1.7"<br />

Fig. B<br />

Fig. D<br />

Fig. E<br />

S2 Model<br />

Fig. G<br />

See page 1-37 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-36<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 55 - 80W Lamps<br />

FT5<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

1<br />

2<br />

3<br />

Input<br />

Volts<br />

FT55W/2G11 - 55W (F55BX, FT55DL)<br />

120<br />

RS Standard<br />

277<br />

120-277<br />

347-480<br />

120<br />

277<br />

120-277<br />

347-480<br />

120-277<br />

347-480<br />

Lamp<br />

Starting<br />

Method<br />

PS<br />

RS<br />

PS<br />

PS<br />

Ballast<br />

Family<br />

Centium<br />

Standard<br />

Centium<br />

Centium<br />

4<br />

120-277<br />

PS Centium<br />

347-480<br />

FT80W/2G11 - 80W (PL-L80W, FT80DL)<br />

1 120-277 PS Centium ICN-1S80<br />

Catalog Number<br />

REL-1TTS50<br />

VEL-1TTS50<br />

ICN-2S54<br />

ICN-2S54-90C<br />

HCN-2S54-90C<br />

REL-2TTS50<br />

VEL-2TTS50<br />

ICN-2S54<br />

ICN-2S54-90C<br />

HCN-2S54-90C<br />

ICN-4S54-90C-2LS<br />

ICN-4S54-90C-2LS-G<br />

HCN-4S54-90C-2LS-G<br />

ICN-4S54-90C-2LS<br />

ICN-4S54-90C-2LS<br />

HCN-4S54-90C-2LS-G<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

51<br />

58<br />

58<br />

100<br />

112-109<br />

112<br />

169-166<br />

178-176<br />

222-217<br />

228-226<br />

91-89<br />

Ballast<br />

Factor<br />

0.85<br />

0.92<br />

0.92<br />

0.84<br />

0.90<br />

0.90<br />

0.90<br />

0.90<br />

0.90<br />

0.90<br />

1.00<br />

Max.<br />

THD<br />

%<br />

20<br />

15<br />

10<br />

20<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.43<br />

0.20<br />

0.49-0.22<br />

0.17-0.13<br />

0.83<br />

0.40<br />

0.94-0.41<br />

0.33-0.24<br />

1.41-0.61<br />

0.52-0.37<br />

1.86-0.80<br />

0.66-0.47<br />

0.76-0.33<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

50/10<br />

0/-18<br />

50/10<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

A<br />

D<br />

A<br />

D<br />

E<br />

G<br />

E<br />

G<br />

D<br />

Wiring<br />

Dia.<br />

93<br />

73<br />

94<br />

74<br />

*75<br />

75<br />

73<br />

ELECTRONIC<br />

FLUORESCENT<br />

BLACK/WHITE<br />

WHITE<br />

BALLAST<br />

Diag. 70<br />

BLUE<br />

RED<br />

BLACK<br />

WHITE<br />

BALLAST<br />

Diag. 71<br />

BLUE<br />

BLUE<br />

RED<br />

BLACK<br />

WHITE<br />

BLUE<br />

BLUE<br />

BALLAST BLUE<br />

Diag. 72<br />

RED<br />

For 1 lamp operation, do not use yellow leads<br />

Diag. 73<br />

*For 3-lamp operation connect<br />

lamps between RED and<br />

BLUE, BROWN and<br />

BLU/WHT, YELLOW and<br />

BLU/WHT.<br />

LINE<br />

BLK/WHT<br />

WHITE<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

Diag. 74 Diag. 75<br />

DIAG. 93<br />

LINE<br />

BLACK<br />

WHITE<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors See page 1-36 for Dimensions<br />

DIAG. 94<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-37


2D<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 10 - 21W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

CFS10W/GR10q - 10W 2D Lamp (F10 2D/4P)<br />

ICF-2S13-H1-LD<br />

1<br />

2<br />

120-277<br />

120-277<br />

PS<br />

PS<br />

SmartMate<br />

SmartMate<br />

ICF-2S13-H1-LD-K ➀<br />

ICF-2S13-M1-BS<br />

ICF-2S13-M1-LS<br />

ICF-2S13-H1-LD<br />

ICF-2S13-H1-LD-K ➀<br />

ICF-2S13-M1-BS<br />

ICF-2S13-M1-LS<br />

CFS16W/GR10q - 16W 2D Lamp (F16 2D/4P)<br />

ICF-2S13-H1-LD<br />

1 120-277 PS SmartMate<br />

ICF-2S13-H1-LD-K ➀<br />

ICF-2S13-M1-BS<br />

ICF-2S13-M1-LS<br />

ICF-2S18-H1-LD<br />

2 120-277 PS SmartMate<br />

ICF-2S18-H1-LD-K ➀<br />

ICF-2S18-M1-BS<br />

ICF-2S18-M1-LS<br />

CFS21W/GR10q - 21W 2D Lamp (F21 2D/4P)<br />

ICF-2S18-H1-LD<br />

1 120-277 PS SmartMate<br />

ICF-2S18-H1-LD-K ➀<br />

ICF-2S18-M1-BS<br />

ICF-2S18-M1-LS<br />

ICF-2S18-H1-LD<br />

ICF-2S18-H1-LD-K ➀<br />

ICF-2S18-M1-BS<br />

2 120-277 PS SmartMate<br />

ICF-2S18-M1-LS<br />

ICF-2S26-H1-LD<br />

ICF-2S26-H1-LD-K ➀<br />

ICF-2S26-M1-BS<br />

ICF-2S26-M1-LS<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

13<br />

23<br />

17<br />

37<br />

20<br />

40<br />

51<br />

Ballast<br />

Factor<br />

1.05<br />

0.95<br />

1.00<br />

1.00<br />

0.90<br />

0.91<br />

1.12<br />

Max.<br />

THD<br />

%<br />

15<br />

15<br />

15<br />

10<br />

15<br />

10<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.11-0.05<br />

0.19-0.09<br />

0.14-0.06<br />

0.31-0.13<br />

0.16-0.07<br />

0.33-0.14<br />

0.42-0.18<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

Size 1<br />

Size 1<br />

Size 1<br />

Size 1<br />

Size 1<br />

Size 1<br />

Wiring<br />

Dia.<br />

160<br />

159<br />

160<br />

159<br />

160<br />

159<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-38<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 28 - 38W Lamps<br />

2D<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

CFS28W/GR10q - 28W 2D Lamp (F28 2D/4P)<br />

1<br />

2<br />

120-277<br />

120-277<br />

PS<br />

PS<br />

SmartMate<br />

SmartMate<br />

ICF-1D38-H1-LD<br />

ICF-2S42-M2-BS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LD-K ➀<br />

ICF-2S42-M2-LS<br />

ICF-2S42-90C-M2-BS<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

CFS38W/GR10q - 38W 2D Lamp (F38 2D/4P)<br />

1 120-277 PS SmartMate ICF-1D38-H1-LD<br />

ICF-2S42-M2-BS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LD-K ➀<br />

2 120-277 PS SmartMate ICF-2S42-M2-LS<br />

ICF-2S42-90C-M2-BS<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

27<br />

57<br />

57<br />

31<br />

62<br />

62<br />

Ballast<br />

Factor<br />

1.00<br />

1.00<br />

1.00<br />

0.85<br />

0.80<br />

0.80<br />

Max.<br />

THD<br />

%<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.23-0.10<br />

0.48-0.21<br />

0.48-0.21<br />

0.26-0.11<br />

0.55-0.23<br />

0.55-0.23<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

Size 1<br />

Size 2<br />

Size 1<br />

Size 2<br />

Wiring<br />

Dia.<br />

160<br />

159<br />

160<br />

159<br />

ELECTRONIC<br />

FLUORESCENT<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

See page 1-38 for Dimensions and Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-39


T5<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 8 - 13W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

F8T5 (8W)<br />

RMB-1P13-L2<br />

10 1.30 150 0.16<br />

1 120 IS Matchbox † RMB-1P13-S1<br />

0/-18<br />

RMB-2P13-L2<br />

19 1.30 125 0.27<br />

2 120 IS Matchbox † RMB-2P13-S2<br />

0/-18<br />

RMB-1P13-S2-H<br />

10 1.20 20 0.08<br />

RMB-2P13-S3-H<br />

19 1.25 10 0.16<br />

(1) F8T5 & (1) F13T5 {(1) 8W & (1) 13W}<br />

RMB-2P13-L2<br />

23 1.10 125 0.33<br />

1 120 IS Matchbox † RMB-2P13-S2<br />

0/-18<br />

RMB-2P13-S3-H<br />

23 1.10 10 0.20<br />

F13T5 (13W)<br />

RMB-1P13-L2<br />

14 1.00 150 0.21<br />

1 120 IS Matchbox † RMB-1P13-S1<br />

0/-18<br />

RMB-2P13-L2<br />

27 0.95 125 0.38<br />

2 120 IS Matchbox † RMB-2P13-S2<br />

0/-18<br />

RMB-1P13-S2-H<br />

14 0.95 15 0.12<br />

RMB-2P13-S3-H<br />

28 0.95 10 0.24<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Dim.<br />

L2<br />

S1<br />

S2<br />

L2<br />

S2<br />

S3<br />

L2<br />

S1<br />

S2<br />

L2<br />

S1<br />

S2<br />

L2<br />

S2<br />

S3<br />

Wiring<br />

Dia.<br />

163<br />

162<br />

162<br />

163<br />

162<br />

† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

S1 Model<br />

1.05"<br />

8.91"<br />

9.50"<br />

Fig. A2<br />

1.08"<br />

Fig. D<br />

L2 Model<br />

S2 Model<br />

S3 Model<br />

1 or 2 lamp linear ballast, plastic enclosure<br />

See page 1-41 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-40<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 14 - 35W Lamps<br />

T5<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

F14T5 (14W)<br />

1<br />

2<br />

120<br />

120-277<br />

120-277<br />

3 120-277<br />

F21T5 (21W)<br />

1<br />

2<br />

1<br />

2<br />

Input<br />

Volts<br />

120<br />

120-277<br />

120-277<br />

120-277<br />

F28T5 (28W)<br />

120-277<br />

120-277<br />

F35T5 (35W)<br />

1 120-277<br />

2 120-277<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

PS<br />

IS<br />

PS<br />

PS<br />

PS<br />

IS<br />

PS<br />

IS<br />

PS<br />

IS<br />

PS<br />

IS<br />

PS<br />

PS<br />

PS<br />

Ballast<br />

Family<br />

Matchbox †<br />

Centium<br />

Matchbox †<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Catalog Number<br />

RMB-1P13-L2<br />

RMB-1P13-S1<br />

RMB-1P13-S2-H<br />

ICN-132-MC<br />

ICN-2S28<br />

RMB-2P13-L2<br />

RMB-2P13-S2<br />

RMB-2P13-S3-H<br />

ICN-2M32-MC<br />

ICN-2S28<br />

ICN-3S14-D<br />

ICN-3S14-D<br />

ICN-132-MC<br />

ICN-2S28<br />

ICN-2M32-MC<br />

ICN-2S28<br />

ICN-132-MC<br />

ICN-2S28<br />

ICN-2M32-MC<br />

ICN-2S28<br />

ICN-2S28<br />

ICN-2S28<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

14<br />

14<br />

19<br />

19<br />

27<br />

28<br />

36<br />

34<br />

36<br />

50<br />

26<br />

26<br />

50<br />

48<br />

34<br />

33<br />

68<br />

64-63<br />

41<br />

80-77<br />

Ballast<br />

Factor<br />

0.95<br />

0.90<br />

1.05<br />

1.07<br />

0.90<br />

0.90<br />

1.05<br />

1.06<br />

1.10<br />

1.00<br />

1.05<br />

1.03<br />

1.05<br />

1.02<br />

1.05<br />

1.04<br />

1.05<br />

1.03<br />

1.01<br />

1.00<br />

Max.<br />

THD<br />

%<br />

150<br />

15<br />

20<br />

20<br />

125<br />

10<br />

20<br />

10<br />

10<br />

10<br />

15<br />

15<br />

15<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.21<br />

0.12<br />

0.15-0.07<br />

0.16-0.07<br />

0.40<br />

0.24<br />

0.30-0.13<br />

0.29-0.13<br />

0.31-0.13<br />

0.42-0.18<br />

0.21-0.09<br />

0.21-0.10<br />

0.42-0.18<br />

0.40-0.17<br />

0.28-0.12<br />

0.28-0.12<br />

0.57-0.25<br />

0.55-0.23<br />

0.34-0.15<br />

0.67-0.28<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

32/0<br />

0/-18<br />

32/0<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

L2<br />

S1<br />

S2<br />

A2<br />

D<br />

L2<br />

S2<br />

S3<br />

A2<br />

D<br />

D<br />

D<br />

A2<br />

D<br />

A2<br />

D<br />

A2<br />

D<br />

A2<br />

D<br />

D<br />

D<br />

Wiring<br />

Dia.<br />

163<br />

63<br />

73<br />

162<br />

64<br />

74<br />

172<br />

171<br />

63<br />

73<br />

64<br />

74<br />

63<br />

73<br />

64<br />

74<br />

73<br />

74<br />

ELECTRONIC<br />

FLUORESCENT<br />

† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

See page 1-40 for Dimensions<br />

WHITE<br />

BLACK<br />

BALLAST<br />

BLUE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

LAMP<br />

LINE<br />

LAMP<br />

LINE<br />

LAMP<br />

For 1 lamp operation, do not use yellow leads<br />

Diag. 73<br />

Diag. 63<br />

Diag. 64<br />

* For Single Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

Diag. 74<br />

* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-41


T5 and T5/HO<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 22 - 55W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

FC9T5 (22W Circline)<br />

120 IS<br />

1<br />

2<br />

Input<br />

Volts<br />

120-277<br />

120-277<br />

Lamp<br />

Starting<br />

Method<br />

PS<br />

PS<br />

Ballast<br />

Family<br />

Matchbox †<br />

SmartMate<br />

Centium<br />

Centium<br />

Catalog Number<br />

RMB-1P26-S2<br />

ICF-1D38-H1-LD<br />

ICN-2S24<br />

ICN-2S39<br />

ICN-2S24<br />

ICN-2S39<br />

FC12T5 (40W Circline)<br />

SmartMate ICF-1D38-H1-LD<br />

1 120-277 PS<br />

ICN-2S24<br />

Centium<br />

ICN-2S39<br />

2 120-277 PS Centium ICN-2S39<br />

(1) FC9T5 & (1) FC12T5 {(1) 22W & (1) 40W Circline}<br />

ICF-2S42-M2-BS<br />

ICF-2S42-M2-LD<br />

ICF-2S42-M2-LD-K ➀<br />

1&1 120-277 PS<br />

SmartMate ICF-2S42-M2-LS<br />

ICF-2S42-90C-M2-BS<br />

ICF-2S42-90C-M2-LD<br />

ICF-2S42-90C-M2-LS<br />

Centium ICN-2S39<br />

FC12T5/HO (55W Circline)<br />

ICN-2S54<br />

120-277<br />

1<br />

PS Centium ICN-2S54-90C<br />

347-480<br />

HCN-2S54-90C<br />

ICN-2S54<br />

120-277<br />

2<br />

PS Centium ICN-2S54-90C<br />

347-480<br />

HCN-2S54-90C<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

25<br />

25<br />

27<br />

29<br />

52<br />

54<br />

38<br />

40<br />

42<br />

80<br />

61<br />

68<br />

1.00<br />

1.00<br />

1.02<br />

1.12<br />

1.00<br />

1.10<br />

0.95<br />

0.84<br />

0.92<br />

0.90<br />

0.85<br />

1.00<br />

150<br />

15<br />

10<br />

15<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

61 0.85 10<br />

55<br />

55<br />

106-103<br />

106<br />

Ballast<br />

Factor<br />

0.87<br />

0.87<br />

0.85<br />

0.85<br />

Max.<br />

THD<br />

%<br />

10<br />

15<br />

10<br />

10<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.39<br />

0.21-0.09<br />

0.23-0.10<br />

0.24-0.12<br />

0.44-0.19<br />

0.46-0.20<br />

0.32-0.14<br />

0.34-0.15<br />

0.35-0.16<br />

0.68-0.29<br />

0.51-0.22<br />

0.51-0.22<br />

0.58-0.25<br />

0.46-0.21<br />

0.16-0.12<br />

0.89-0.38<br />

0.31-0.22<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

S2<br />

Size 1<br />

D<br />

D<br />

Size 1<br />

D<br />

D<br />

Size 1<br />

D<br />

163<br />

73<br />

74<br />

163<br />

73<br />

74<br />

162<br />

Size 1 162<br />

D<br />

D<br />

Wiring<br />

Dia.<br />

74<br />

73<br />

74<br />

† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />

For 1 lamp operation, do not use yellow leads<br />

Diag. 73<br />

Diag. 74<br />

Diag. 75<br />

*For 3-lamp operation connect<br />

lamps between RED and<br />

BLUE, BROWN and<br />

BLU/WHT, YELLOW and<br />

BLU/WHT.<br />

* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors See page 1-43 for Dimensions<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-42<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 24 - 80W Lamps<br />

T5/HO<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

F24T5/HO (24W)<br />

1<br />

2<br />

1<br />

120-277<br />

120-277<br />

F39T5/HO (39W)<br />

2 120-277<br />

F54T5/HO (54W)<br />

1<br />

2<br />

3<br />

Input<br />

Volts<br />

120-277<br />

120-277<br />

347-480<br />

120-277<br />

347-480<br />

120-277<br />

347-480<br />

120-277<br />

4<br />

347-480<br />

F80T5/HO (80W)<br />

1 120-277<br />

Lamp<br />

Starting<br />

Method<br />

PS<br />

PS<br />

PS<br />

PS<br />

PS<br />

PS<br />

PS<br />

PS<br />

PS<br />

Ballast<br />

Family<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Centium<br />

Catalog Number<br />

ICN-2S24<br />

ICN-2S39<br />

ICN-2S24<br />

ICN-2S39<br />

ICN-2S24<br />

ICN-2S39<br />

ICN-2S39<br />

ICN-2S54<br />

ICN-2S54-90C<br />

HCN-2S54-90C<br />

ICN-2S54<br />

ICN-2S54-90C<br />

HCN-2S54-90C<br />

ICN-4S54-90C-2LS<br />

ICN-4S54-90C-2LS-G<br />

HCN-4S54-90C-2LS-G<br />

ICN-4S54-90C-2LS<br />

ICN-4S54-90C-2LS-G<br />

HCN-4S54-90C-2LS-G<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

27<br />

29<br />

52<br />

55<br />

40<br />

43<br />

87-85<br />

62<br />

185<br />

120-117<br />

120-119<br />

182-179<br />

182-179<br />

188-186<br />

240-234<br />

240-234<br />

239-237<br />

Ballast<br />

Factor<br />

1.02<br />

1.12<br />

1.00<br />

1.10<br />

0.90<br />

1.02<br />

1.00<br />

1.02<br />

0.95<br />

1.00<br />

1.00<br />

1.00<br />

1.00<br />

1.04<br />

1.00<br />

1.00<br />

1.00<br />

Max.<br />

THD<br />

%<br />

0.23-0.10<br />

0.25-0.12<br />

0.44-0.19<br />

0.47-0.21<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

-20/-29<br />

0/-18<br />

-20/-29<br />

0/-18<br />

0/-18<br />

0/-18<br />

ICN-1S80 91-89 1.00 10 0.76-0.33 0/-18 D<br />

10<br />

15<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

Line<br />

Current<br />

(Amps)<br />

0.34-0.15<br />

0.36-0.16<br />

0.73-0.31<br />

0.52-0.23<br />

0.18-0.13<br />

1.00-0.43<br />

0.35-0.25<br />

1.52-0.66<br />

1.52-0.66<br />

0.54-0.39<br />

2.00-0.86<br />

2.00-0.86<br />

0.69-0.50<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

D<br />

D<br />

D<br />

D<br />

D<br />

D<br />

D<br />

G<br />

D<br />

G<br />

Wiring<br />

Dia.<br />

73<br />

74<br />

73<br />

74<br />

73<br />

74<br />

*75<br />

75<br />

73<br />

ELECTRONIC<br />

FLUORESCENT<br />

S2 Model<br />

Fig. D<br />

Fig. G<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

See page 1-42 for Wiring Diagrams<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-43


T8<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 17W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

1<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

Lamp<br />

Starting<br />

Method<br />

F17T8, FBO16T8 (17W)<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

Ballast<br />

Family<br />

AmbiStar ‡<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Mark 5<br />

Catalog Number<br />

REB-2P32-SC<br />

REL-1P32-LW-SC<br />

REL-1P32-SC<br />

REL-1P32-HL-SC<br />

REL-2P17-RH-TP<br />

RCN-1S32-SC<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

VEL-1P32-LW-SC<br />

VEL-1P32-SC<br />

VEL-1P32-HL-SC<br />

VEL-2P17-RH-TP<br />

VCN-1S32-SC<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

ICN-132-MC<br />

ICN-1P32-LW-SC<br />

ICN-1P32-SC<br />

ICN-2P32-LW-SC<br />

ICN-2P32-SC<br />

IOP-1P32-LW-SC<br />

IOP-1P32-SC<br />

IOP-1P32-HL-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-1S32-LW-SC<br />

IOP-1S32-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IIC-132-SC<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

19 1.02 150<br />

18<br />

20<br />

24<br />

22<br />

22<br />

17<br />

19<br />

18<br />

20<br />

24<br />

22<br />

22<br />

17<br />

19<br />

17<br />

16<br />

19<br />

19<br />

22<br />

15<br />

16<br />

22<br />

18<br />

19<br />

25<br />

14<br />

16<br />

15<br />

17<br />

18<br />

Ballast<br />

Factor<br />

0.87<br />

0.95<br />

1.22<br />

1.15<br />

1.00<br />

0.89<br />

1.02<br />

0.87<br />

0.95<br />

1.22<br />

1.15<br />

1.00<br />

0.89<br />

1.02<br />

0.88<br />

0.80<br />

0.93<br />

0.90<br />

1.07<br />

0.80<br />

0.90<br />

1.23<br />

0.90<br />

1.06<br />

1.42<br />

0.79<br />

0.97<br />

0.78<br />

0.97<br />

0.88<br />

Max.<br />

THD<br />

%<br />

25<br />

30<br />

20<br />

25<br />

10<br />

20<br />

15<br />

25<br />

30<br />

20<br />

25<br />

10<br />

20<br />

15<br />

20<br />

10<br />

15<br />

20<br />

15<br />

10<br />

10<br />

15<br />

20<br />

15<br />

20<br />

10<br />

10<br />

15<br />

15<br />

15<br />

Line<br />

Current<br />

(Amps)<br />

0.30<br />

0.17<br />

0.19<br />

0.21<br />

0.19<br />

0.19<br />

0.15<br />

0.17<br />

0.08<br />

0.08<br />

0.10<br />

0.09<br />

0.08<br />

0.07<br />

0.08<br />

0.14-0.06<br />

0.13-0.06<br />

0.16-0.07<br />

0.16-0.07<br />

0.18-0.09<br />

0.13-0.06<br />

0.14-0.07<br />

0.19-0.08<br />

0.15-0.07<br />

0.17-0.08<br />

0.21-0.10<br />

0.12-0.05<br />

0.14-0.07<br />

0.12-0.06<br />

0.14-0.07<br />

0.15-0.07<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

Dim.<br />

B<br />

A<br />

B<br />

B<br />

A<br />

B<br />

A2<br />

B<br />

Wiring<br />

Dia.<br />

*64<br />

63<br />

*64<br />

20<br />

*64<br />

63<br />

*64<br />

20<br />

*64<br />

63<br />

*64<br />

63<br />

*64<br />

20<br />

39<br />

20<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

See page 1-47 for Wiring Diagrams<br />

1.18"<br />

8.90"<br />

9.5"<br />

Fig. A<br />

1.7"<br />

Fig. B<br />

1.05"<br />

8.91"<br />

9.50"<br />

Fig. G<br />

1.08"<br />

Fig. A2<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-44<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 17W Lamps<br />

T8<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

2<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

F17T8, FBO16T8 (17W)<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

Ballast<br />

Family<br />

AmbiStar ‡<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Optanium<br />

Mark 5<br />

Standard<br />

Catalog Number<br />

REB-2P32-SC<br />

REL-2P17-RH-TP<br />

REL-2P32-LW-SC<br />

REL-2P32-SC<br />

REL-2P32-HL-SC<br />

REL-3P32-LW-SC<br />

RCN-2S32-SC<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

VEL-2P17-RH-TP<br />

VEL-2P32-LW-SC<br />

VEL-2P32-SC<br />

VEL-2P32-HL-SC<br />

VEL-3P32-LW-SC<br />

VCN-2S32-SC<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

ICN-2M32-MC<br />

ICN-2P32-LW-SC<br />

ICN-2P32-SC<br />

ICN-3P32-LW-SC<br />

ICN-3P32-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IIC-2S32-SC<br />

GEL-2P32-LW-RH-TP<br />

GEL-2P32-SC<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

31<br />

34<br />

30<br />

34<br />

43<br />

34<br />

39<br />

27<br />

31<br />

29<br />

35<br />

34<br />

30<br />

34<br />

43<br />

34<br />

39<br />

27<br />

31<br />

29<br />

35<br />

31<br />

28<br />

33<br />

32<br />

38<br />

27<br />

31<br />

41<br />

31<br />

35<br />

47<br />

25<br />

29<br />

33<br />

31<br />

34<br />

Ballast<br />

Factor<br />

0.91<br />

0.98<br />

0.82<br />

0.98<br />

1.26<br />

0.87<br />

1.00<br />

0.80<br />

0.90<br />

0.87<br />

0.97<br />

0.98<br />

0.82<br />

0.98<br />

1.26<br />

0.87<br />

1.00<br />

0.80<br />

0.90<br />

0.87<br />

0.97<br />

0.88<br />

0.79<br />

0.93<br />

0.88<br />

1.07<br />

0.80<br />

0.90<br />

0.87<br />

0.87<br />

1.01<br />

1.37<br />

0.73<br />

0.90<br />

0.88<br />

0.82<br />

0.92<br />

Max.<br />

THD<br />

%<br />

140<br />

20<br />

30<br />

30<br />

20<br />

20<br />

10<br />

10<br />

10<br />

15<br />

15<br />

20<br />

30<br />

30<br />

20<br />

20<br />

10<br />

15<br />

15<br />

20<br />

15<br />

10<br />

20<br />

15<br />

20<br />

15<br />

10<br />

10<br />

15<br />

20<br />

15<br />

10-30<br />

10<br />

15<br />

15<br />

30<br />

30<br />

Line<br />

Current<br />

(Amps)<br />

0.45<br />

0.29<br />

0.29<br />

0.29<br />

0.36<br />

0.28<br />

0.33<br />

0.23<br />

0.26<br />

0.25<br />

0.30<br />

0.13<br />

0.12<br />

0.13<br />

0.16<br />

0.13<br />

0.15<br />

0.10<br />

0.11<br />

0.12<br />

0.14<br />

0.26-0.11<br />

0.23-0.10<br />

0.28-0.13<br />

0.27-0.18<br />

0.32-0.14<br />

0.23-0.10<br />

0.26-0.11<br />

0.34-0.15<br />

0.26-0.12<br />

0.30-0.14<br />

0.39-0.20<br />

0.21-0.09<br />

0.24-0.11<br />

0.27-0.12<br />

0.09<br />

0.11<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A2<br />

B<br />

A<br />

B<br />

Wiring<br />

Dia.<br />

*64<br />

64<br />

*65<br />

21<br />

64<br />

*65<br />

64<br />

*65<br />

21<br />

64<br />

*65<br />

64<br />

*65<br />

64<br />

*65<br />

21<br />

64<br />

ELECTRONIC<br />

FLUORESCENT<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

See page 1-44 for Dimensions<br />

See page 1-47 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-45


T8<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 17W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

3<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

F17T8, FBO16T8 (17W)<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

RS<br />

Ballast<br />

Family<br />

AmbiStar ‡<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Optanium<br />

Mark 5<br />

Centium<br />

Catalog Number<br />

REB-4P32-SC<br />

REL-3P32-LW-SC<br />

REL-3P32-SC<br />

REL-3P32-HL-SC<br />

REL-4P32-LW-SC<br />

RCN-3S32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

ROP-4P32-LW-SC<br />

ROP-4P32-SC<br />

ROP-4P32-HL-90C<br />

VEL-3P32-LW-SC<br />

VEL-3P32-SC<br />

VEL-3P32-HL-SC<br />

VEL-4P32-LW-SC<br />

VCN-3S32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

VOP-4P32-LW-SC<br />

VOP-4P32-SC<br />

VOP-4P32-HL-90C<br />

ICN-3P32-LW-SC<br />

ICN-3P32-SC<br />

ICN-4P32-LW-SC<br />

ICN-4P32-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-3S32-LW-SC<br />

IOP-3S32-SC<br />

IIC-3S32-SC<br />

GCN-3S32<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

44<br />

44<br />

47<br />

61<br />

47<br />

61<br />

39<br />

45<br />

41<br />

49<br />

65<br />

44<br />

47<br />

61<br />

47<br />

61<br />

39<br />

45<br />

41<br />

49<br />

61<br />

42<br />

48<br />

43<br />

53<br />

40<br />

45<br />

59<br />

43<br />

49<br />

69<br />

37<br />

43<br />

50<br />

64<br />

Ballast<br />

Factor<br />

0.81<br />

0.77<br />

0.99<br />

1.22<br />

0.84<br />

1.00<br />

0.80<br />

0.91<br />

0.85<br />

0.95<br />

1.25<br />

0.77<br />

0.99<br />

1.22<br />

0.84<br />

1.00<br />

0.80<br />

0.91<br />

0.85<br />

0.95<br />

1.25<br />

0.80<br />

0.92<br />

0.85<br />

1.04<br />

0.81<br />

0.90<br />

1.22<br />

0.85<br />

1.00<br />

1.28<br />

0.72<br />

0.89<br />

0.88<br />

1.04<br />

Max.<br />

THD<br />

%<br />

135<br />

20<br />

20<br />

20<br />

20<br />

10<br />

10<br />

10<br />

15<br />

15<br />

15<br />

20<br />

20<br />

20<br />

20<br />

10<br />

15<br />

15<br />

15<br />

15<br />

15<br />

15<br />

15<br />

15<br />

15<br />

10<br />

10<br />

10-15<br />

20<br />

15<br />

10-15<br />

10<br />

10<br />

15<br />

30<br />

Line<br />

Current<br />

(Amps)<br />

0.87<br />

0.37<br />

0.39<br />

0.51<br />

0.39<br />

0.51<br />

0.33<br />

0.38<br />

0.35<br />

0.41<br />

0.55<br />

0.16<br />

0.17<br />

0.23<br />

0.17<br />

0.22<br />

0.15<br />

0.17<br />

0.16<br />

0.18<br />

0.24<br />

0.35-0.16<br />

0.39-0.17<br />

0.36-0.16<br />

0.45-0.20<br />

0.34-0.15<br />

0.38-0.17<br />

0.49-0.22<br />

0.36-0.17<br />

0.41-0.18<br />

0.58-0.26<br />

0.31-0.14<br />

0.36-0.16<br />

0.41-0.19<br />

0.19<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

G<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

*66<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

65<br />

*66<br />

65<br />

*66<br />

30<br />

30<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

See page 1-44 for Dimensions<br />

See page 1-47 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-46<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 17W Lamps<br />

T8<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

4<br />

Input<br />

Volts<br />

F17T8, FBO16T8 (17W)<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

Ballast<br />

Family<br />

AmbiStar ‡<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Optanium<br />

Standard<br />

Catalog Number<br />

REB-4P32-SC<br />

REL-4P32-LW-SC<br />

REL-4P32-SC<br />

RCN-4S32-SC<br />

ROP-4P32-SC<br />

ROP-4P32-LW-SC<br />

ROP-4P32-HL-90C<br />

VEL-4P32-LW-SC<br />

VEL-4P32-SC<br />

VCN-4S32-SC<br />

VOP-4P32-LW-SC<br />

VOP-4P32-SC<br />

VOP-4P32-HL-90C<br />

ICN-4P32-LW-SC<br />

ICN-4P32-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-4S32-LW-SC<br />

IOP-4S32-SC<br />

GEL-4P32-LW<br />

GEL-4P32-RH-TP<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

52<br />

54<br />

61<br />

79<br />

58<br />

50<br />

77<br />

54<br />

61<br />

79<br />

50<br />

58<br />

77<br />

53<br />

64<br />

53<br />

58<br />

79<br />

48<br />

57<br />

54<br />

56<br />

Ballast<br />

Factor<br />

0.82<br />

0.77<br />

0.96<br />

1.00<br />

0.90<br />

0.80<br />

1.18<br />

0.77<br />

0.96<br />

1.00<br />

0.80<br />

0.90<br />

1.18<br />

0.79<br />

0.93<br />

0.81<br />

0.90<br />

1.22<br />

0.72<br />

0.89<br />

0.77<br />

0.88<br />

Max.<br />

THD<br />

%<br />

135<br />

20<br />

20<br />

10<br />

10<br />

10<br />

10<br />

20<br />

20<br />

10<br />

15<br />

15<br />

10<br />

15<br />

10<br />

10<br />

10<br />

10-15<br />

10<br />

10<br />

30<br />

30<br />

Line<br />

Current<br />

(Amps)<br />

1.00<br />

0.46<br />

0.51<br />

0.67<br />

0.49<br />

0.43<br />

0.65<br />

0.20<br />

0.22<br />

0.29<br />

0.19<br />

0.22<br />

0.28<br />

0.44-0.19<br />

0.54-0.23<br />

0.45-0.20<br />

0.49-0.22<br />

0.66-0.29<br />

0.40-0.18<br />

0.47-0.21<br />

0.18<br />

0.18<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

G<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

*66<br />

66<br />

138<br />

66<br />

66<br />

138<br />

66<br />

66<br />

138<br />

66<br />

ELECTRONIC<br />

FLUORESCENT<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

LAMP<br />

LAMP<br />

LAMP<br />

LAMP<br />

LINE<br />

RED<br />

RED<br />

BLUE/WHITE<br />

BLUE/WHITE<br />

BLACK<br />

WHITE<br />

BALLAST<br />

Diag. 30<br />

YELLOW<br />

YELLOW<br />

BLUE<br />

BLUE<br />

LINE<br />

* YEL<br />

BLUE<br />

* YEL<br />

BLUE<br />

BALLAST<br />

WHITE<br />

RED<br />

BLACK<br />

RED<br />

*FOR SINGLE LAMP OPERATION, INSULATE<br />

YELLOW LEADS INDIVIDUALLY FOR 600V<br />

Diag. 39<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

BLUE<br />

LINE<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

Diag. 63<br />

Diag. 64<br />

* For Single Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

LAMP<br />

Diag. 65<br />

* For Two Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

WHITE<br />

BLACK<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

LAMP<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

Diag. 66<br />

* For Three Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

Diag. 138<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

See page 1-44 for Dimensions<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-47


T8<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 25W - 36" Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

1<br />

Input<br />

Volts<br />

F25T8, FBO24T8 (25W - 36")<br />

AmbiStar ‡<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

RS<br />

Ballast<br />

Family<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Mark 5<br />

Standard<br />

Centium<br />

Catalog Number<br />

REB-2P32-SC<br />

REL-1P32-LW-SC<br />

REL-1P32-SC<br />

REL-1P32-HL-SC<br />

REL-2P32-SC<br />

REL-2P32-HL-SC<br />

RCN-1S32-SC<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

VEL-1P32-LW-SC<br />

VEL-1P32-SC<br />

VEL-1P32-HL-SC<br />

VEL-2P32-SC<br />

VEL-2P32-HL-SC<br />

VCN-1S32-SC<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

ICN-132-MC<br />

ICN-1P32-LW-SC<br />

ICN-1P32-SC<br />

ICN-2P32-LW-SC<br />

ICN-2P32-SC<br />

IOP-1P32-LW-SC<br />

IOP-1P32-SC<br />

IOP-1P32-HL-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-1S32-LW-SC<br />

IOP-1S32-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IIC-132-SC<br />

GEL-2P32-SC<br />

GCN-2P32<br />

GCN-1S32<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

26<br />

24<br />

24<br />

33<br />

30<br />

38<br />

28<br />

24<br />

27<br />

24<br />

24<br />

33<br />

30<br />

38<br />

28<br />

24<br />

27<br />

23<br />

22<br />

26<br />

25<br />

29<br />

21<br />

23<br />

30<br />

24<br />

28<br />

35<br />

20<br />

22<br />

20<br />

23<br />

25<br />

28<br />

32<br />

31<br />

Ballast<br />

Factor<br />

1.00<br />

0.82<br />

0.92<br />

1.21<br />

1.04<br />

1.43<br />

0.95<br />

0.88<br />

1.02<br />

0.82<br />

0.92<br />

1.21<br />

1.10<br />

1.43<br />

0.95<br />

0.88<br />

1.02<br />

0.88<br />

0.80<br />

0.91<br />

0.88<br />

1.06<br />

0.78<br />

0.88<br />

1.22<br />

0.90<br />

1.05<br />

1.40<br />

0.74<br />

0.92<br />

0.73<br />

0.90<br />

0.88<br />

0.92<br />

1.17<br />

0.97<br />

Max.<br />

THD<br />

%<br />

150<br />

20<br />

25<br />

20<br />

30<br />

20<br />

10<br />

15<br />

15<br />

20<br />

25<br />

20<br />

30<br />

20<br />

10<br />

15<br />

15<br />

15<br />

15<br />

10<br />

20<br />

15<br />

10<br />

10<br />

10<br />

10<br />

10<br />

20<br />

10<br />

10<br />

15<br />

15<br />

10<br />

25<br />

25<br />

20<br />

Line<br />

Current<br />

(Amps)<br />

0.39<br />

0.21<br />

0.21<br />

0.28<br />

0.29<br />

0.32<br />

0.24<br />

0.20<br />

0.23<br />

0.09<br />

0.09<br />

0.13<br />

0.13<br />

0.14<br />

0.10<br />

0.09<br />

0.10<br />

0.19-0.09<br />

0.18-0.08<br />

0.22-0.10<br />

0.21-0.10<br />

0.24-0.11<br />

0.17-0.08<br />

0.20-0.09<br />

0.26-0.11<br />

0.20-0.09<br />

0.23-0.10<br />

0.29-0.13<br />

0.16-0.07<br />

0.19-0.08<br />

0.17-0.08<br />

0.19-0.09<br />

0.21-0.09<br />

0.09<br />

0.10<br />

0.09<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

0/-18<br />

32/0<br />

Dim.<br />

B<br />

B<br />

A2<br />

B<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

*64<br />

63<br />

*64<br />

20<br />

*64<br />

63<br />

*64<br />

20<br />

*64<br />

63<br />

*64<br />

63<br />

*64<br />

20<br />

39<br />

20<br />

*64<br />

20<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

See page 1-51 for Wiring Diagrams<br />

1.18"<br />

8.90"<br />

9.5"<br />

Fig. A<br />

1.7"<br />

Fig. B<br />

1.05"<br />

8.91"<br />

9.50"<br />

Fig. G<br />

1.08"<br />

Fig. A2<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-48<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 25W - 36" Lamps<br />

T8<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

2<br />

Input<br />

Volts<br />

F25T8, FBO24T8 (25W - 36")<br />

AmbiStar ‡<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

RS<br />

Ballast<br />

Family<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Mark 5<br />

Standard<br />

Centium<br />

Catalog Number<br />

REB-2P32-SC<br />

REL-2P32-LW-SC<br />

REL-2P32-SC<br />

REL-2P32-HL-SC<br />

REL-3P32-LW-SC<br />

REL-3P32-SC<br />

REL-3P32-HL-SC<br />

RCN-2S32-SC<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

VEL-2P32-LW-SC<br />

VEL-2P32-SC<br />

VEL-2P32-HL-SC<br />

VEL-3P32-LW-SC<br />

VEL-3P32-SC<br />

VEL-3P32-HL-SC<br />

VCN-2S32-SC<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

ICN-2M32-MC<br />

ICN-2P32-LW-SC<br />

ICN-2P32-SC<br />

ICN-3P32-LW-SC<br />

ICN-3P32-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IIC-2S32-SC<br />

GEL-2P32-LW-RH-TP<br />

GEL-2P32-SC<br />

GCN-2P32<br />

GCN-2S32<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

43 0.89 130<br />

41 0.78 25<br />

46 0.90 25<br />

61 1.24 20<br />

46 0.88 20<br />

54 1.06 20<br />

66 1.33 20<br />

53 0.95 10<br />

38 0.79 10<br />

43 0.88 10<br />

49 0.96 10<br />

59 0.96 10<br />

41 0.78 25<br />

46 0.90 25<br />

61 1.24 20<br />

46 0.88 20<br />

54 1.06 20<br />

66 1.33 20<br />

53 0.95 10<br />

38 0.79 10<br />

43 0.88 10<br />

43 0.86 15<br />

49 0.96 10<br />

44 0.88 15<br />

40 0.77 15<br />

48 0.91 10<br />

44 0.85 15<br />

51 1.03 15<br />

39 0.78 10<br />

43 0.88 10<br />

57 1.20 10<br />

43 0.86 10<br />

49 1.00 10<br />

64 1.32 10-15<br />

36 0.71 10<br />

43 0.89 10<br />

47 0.88 10<br />

41 0.78 25<br />

48 0.98 25<br />

47 0.92 15<br />

57 1.00 20<br />

Line<br />

Current<br />

(Amps)<br />

0.61<br />

0.35<br />

0.40<br />

0.51<br />

0.39<br />

0.42<br />

0.56<br />

0.45<br />

0.32<br />

0.37<br />

0.42<br />

0.50<br />

0.15<br />

0.17<br />

0.21<br />

0.17<br />

0.14<br />

0.24<br />

0.20<br />

0.14<br />

0.16<br />

0.16<br />

0.18<br />

0.37-0.16<br />

0.34-0.14<br />

0.40-0.18<br />

0.37-0.16<br />

0.43-0.19<br />

0.32-0.14<br />

0.37-0.16<br />

0.48-0.21<br />

0.36-0.16<br />

0.42-0.18<br />

0.54-0.24<br />

0.30-0.13<br />

0.36-0.16<br />

0.39-0.17<br />

0.12<br />

0.14<br />

0.14<br />

0.16<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

B<br />

B<br />

A2<br />

B<br />

A<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

64<br />

*65<br />

21<br />

64<br />

*65<br />

64<br />

*65<br />

21<br />

64<br />

*65<br />

64<br />

*65<br />

64<br />

*65<br />

21<br />

64<br />

21<br />

ELECTRONIC<br />

FLUORESCENT<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

See page 1-48 for Dimensions<br />

See page 1-51 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-49


T8<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 25W - 36" Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

3<br />

Input<br />

Volts<br />

F25T8, FBO24T8 (25W - 36")<br />

AmbiStar ‡<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

RS<br />

Ballast<br />

Family<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Mark 5<br />

Standard<br />

Centium<br />

Catalog Number<br />

REB-4P32-SC<br />

REL-3P32-LW-SC<br />

REL-3P32-SC<br />

REL-3P32-HL-SC<br />

REL-4P32-LW-SC<br />

REL-4P32-SC<br />

RCN-3S32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

ROP-4P32-LW-SC<br />

ROP-4P32-SC<br />

ROP-4P32-HL-90C<br />

VEL-3P32-LW-SC<br />

VEL-3P32-SC<br />

VEL-3P32-HL-SC<br />

VEL-4P32-LW-SC<br />

VEL-4P32-SC<br />

VCN-3S32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

VOP-4P32-LW-SC<br />

VOP-4P32-SC<br />

VOP-4P32-HL-90C<br />

ICN-3P32-LW-SC<br />

ICN-3P32-SC<br />

ICN-4P32-LW-SC<br />

ICN-4P32-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-3S32-LW-SC<br />

IOP-3S32-SC<br />

IIC-3S32-SC<br />

GEL-3P32-RH-TP<br />

GEL-4P32-LW<br />

GCN-3S32<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

63 0.86 125<br />

59 0.77 20<br />

66 0.93 20<br />

88 1.20 20<br />

62 0.83 20<br />

74 1.04 20<br />

77 0.95 10<br />

65 0.89 10<br />

77 0.88 10<br />

61 0.83 10<br />

70 0.92 10<br />

95 1.25 10<br />

46 0.88 20<br />

66 0.93 15<br />

88 1.20 20<br />

62 0.83 20<br />

74 1.04 20<br />

77 0.95 10<br />

57 0.79 10<br />

65 0.89 10<br />

61 0.83 10<br />

70 0.92 10<br />

95 1.25 10<br />

58 0.79 15<br />

67 0.90 10<br />

62 0.85 10<br />

74 1.01 10<br />

57 0.79 10<br />

64 0.88 10<br />

84 1.20 10<br />

62 0.85 10<br />

71 0.97 10<br />

94 1.28 10<br />

54 0.71 10<br />

64 0.88 10<br />

70 0.88 10<br />

70 0.95 25<br />

62 0.83 30<br />

82 1.02 20<br />

Line<br />

Current<br />

(Amps)<br />

1.14<br />

0.50<br />

0.55<br />

0.74<br />

0.53<br />

0.62<br />

0.65<br />

0.54<br />

0.65<br />

0.52<br />

0.58<br />

0.80<br />

0.17<br />

0.24<br />

0.32<br />

0.22<br />

0.27<br />

0.28<br />

0.21<br />

0.24<br />

0.23<br />

0.26<br />

0.35<br />

0.49-0.21<br />

0.56-0.24<br />

0.52-0.22<br />

0.62-0.27<br />

0.48-0.21<br />

0.54-0.24<br />

0.70-0.31<br />

0.52-0.22<br />

0.59-0.26<br />

0.80-0.35<br />

0.45-0.20<br />

0.53-0.23<br />

0.58-0.25<br />

0.21<br />

0.20<br />

0.25<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

0/-18<br />

32/0<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

G<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

*66<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

65<br />

*66<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

30<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

See page 1-48 for Dimensions<br />

See page 1-51 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-50<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 25W - 36" Lamps<br />

T8<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

F25T8, FBO24T8 (25W - 36")<br />

AmbiStar ‡<br />

4<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

Ballast<br />

Family<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Standard<br />

Catalog Number<br />

REB-4P32-SC<br />

REL-4P32-LW-SC<br />

REL-4P32-SC<br />

RCN-4S32-SC<br />

ROP-4P32-LW-SC<br />

ROP-4P32-SC<br />

ROP-4P32-HL-90C<br />

VEL-4P32-LW-SC<br />

VEL-4P32-SC<br />

VCN-4S32-SC<br />

VOP-4P32-LW-SC<br />

VOP-4P32-SC<br />

VOP-4P32-HL-90C<br />

ICN-4P32-LW-SC<br />

ICN-4P32-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-4S32-LW-SC<br />

IOP-4S32-SC<br />

GEL-4P32-LW<br />

GEL-4P32-RH-TP<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

77 0.81 125<br />

76 0.76 20<br />

89 0.94 20<br />

101 0.95 10<br />

75 0.79 10<br />

85 0.88 10<br />

115 1.17 10<br />

76 0.76 20<br />

89 0.94 15<br />

101 0.95 10<br />

75 0.79 10<br />

85 0.88 10<br />

113 1.17 10<br />

75 0.79 10<br />

89 0.91 10<br />

76 0.79 10<br />

85 0.88 10<br />

113 1.20 10<br />

69 0.72 10<br />

85 0.88 10<br />

76 0.79 25<br />

85 0.88 25<br />

Line<br />

Current<br />

(Amps)<br />

1.31<br />

0.64<br />

0.74<br />

0.84<br />

0.63<br />

0.71<br />

0.97<br />

0.28<br />

0.32<br />

0.36<br />

0.28<br />

0.31<br />

0.41<br />

0.63-0.27<br />

0.74-0.32<br />

0.64-0.27<br />

0.72-0.31<br />

0.96-0.41<br />

0.58-0.25<br />

0.72-0.31<br />

0.23<br />

0.25<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

G<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

66<br />

138<br />

66<br />

66<br />

138<br />

66<br />

66<br />

138<br />

66<br />

ELECTRONIC<br />

FLUORESCENT<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

LAMP<br />

LAMP<br />

LAMP<br />

LAMP<br />

LINE<br />

RED<br />

RED<br />

BLUE/WHITE<br />

BLUE/WHITE<br />

BLACK<br />

WHITE<br />

BALLAST<br />

Diag. 30<br />

YELLOW<br />

YELLOW<br />

BLUE<br />

BLUE<br />

LINE<br />

* YEL<br />

BLUE<br />

* YEL<br />

BLUE<br />

BALLAST<br />

WHITE<br />

RED<br />

BLACK<br />

RED<br />

*FOR SINGLE LAMP OPERATION, INSULATE<br />

YELLOW LEADS INDIVIDUALLY FOR 600V<br />

Diag. 39<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

BLUE<br />

LINE<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

Diag. 63<br />

Diag. 64<br />

* For Single Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

LAMP<br />

Diag. 65<br />

* For Two Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

WHITE<br />

BLACK<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

LAMP<br />

LAMP<br />

LINE<br />

LAMP<br />

Diag. 66<br />

* For Three Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

LAMP<br />

Diag. 138<br />

See page 1-48 for Dimensions<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-51


T8/ES<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 25W - 48" Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

1<br />

2<br />

3<br />

4<br />

Input<br />

Volts<br />

120-277<br />

120-277<br />

120-277<br />

120-277<br />

Lamp<br />

Starting<br />

Method<br />

F32T8/ES (25W - 48")<br />

IS<br />

PS<br />

IS<br />

PS<br />

IS<br />

PS<br />

IS<br />

PS<br />

Ballast<br />

Family<br />

Optanium<br />

Optanium<br />

Optanium<br />

Optanium<br />

Catalog Number<br />

IOP-1P32-LW-SC<br />

IOP-1P32-SC<br />

IOP-1P32-HL-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-1S32-LW-SC<br />

IOP-1S32-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-3S32-LW-SC<br />

IOP-3S32-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-4S32-LW-SC<br />

IOP-4S32-SC<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

21 0.77 10<br />

23 0.87 10<br />

32 1.21 10<br />

24 0.90 10<br />

27 1.05 10<br />

37 1.40 15<br />

21 0.72 10<br />

24 0.88 10<br />

21 0.73 10<br />

24 0.89 10-15<br />

38 0.77 10<br />

44-43 0.87 10<br />

60 1.19 10<br />

43 0.86 10<br />

49 1.00 10<br />

70 1.32 10-20<br />

39-38 0.71 10<br />

45-44 0.88 10<br />

58-57 0.77 10<br />

65-64 0.87 10<br />

95-93 1.20 10<br />

62-61 0.85 10<br />

70-69 0.97 10<br />

101-100 1.27 10<br />

57-56 0.71 10<br />

67-66 0.89 10<br />

77-75 0.77 10<br />

87-85 0.87 10<br />

124-122 1.19 10<br />

74-73 0.71 10<br />

87-85 0.87 10<br />

Line<br />

Current<br />

(Amps)<br />

0.17-0.07<br />

0.20-0.09<br />

0.26-0.12<br />

0.20-0.09<br />

0.23-0.10<br />

0.31-0.14<br />

0.17-0.07<br />

0.20-0.08<br />

0.17-0.08<br />

0.20-0.09<br />

0.32-0.14<br />

0.37-0.06<br />

0.50-0.22<br />

0.36-0.16<br />

0.42-0.18<br />

0.59-0.27<br />

0.32-0.14<br />

0.38-0.16<br />

0.49-0.21<br />

0.55-0.24<br />

0.79-0.35<br />

0.52-0.22<br />

0.59-0.26<br />

0.85-0.37<br />

0.48-0.21<br />

0.56-0.25<br />

0.65-0.28<br />

0.73-0.31<br />

1.05-0.45<br />

0.62-0.27<br />

0.73-0.31<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />

Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />

Max.<br />

THD<br />

%<br />

60/16<br />

60/16<br />

60/16<br />

60/16<br />

Dim.<br />

B<br />

B<br />

B<br />

G<br />

B<br />

B<br />

G<br />

B<br />

Wiring<br />

Dia.<br />

63<br />

*64<br />

20<br />

39<br />

64<br />

*65<br />

21<br />

65<br />

*66<br />

30<br />

66<br />

138<br />

See page 1-57 for Wiring Diagrams<br />

Fig. A<br />

1.18"<br />

1.7"<br />

8.90"<br />

9.5"<br />

Fig. B<br />

1.05"<br />

8.91"<br />

9.50"<br />

Fig. G<br />

1.08"<br />

Fig. A2<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-52<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 28W - 48" Lamps<br />

T8/ES<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

1<br />

2<br />

3<br />

4<br />

Input<br />

Volts<br />

120-277<br />

120-277<br />

120-277<br />

120-277<br />

Lamp<br />

Starting<br />

Method<br />

F32T8/ES (28W - 48")<br />

IS<br />

PS<br />

IS<br />

PS<br />

IS<br />

PS<br />

IS<br />

PS<br />

Ballast<br />

Family<br />

Optanium<br />

Optanium<br />

Optanium<br />

Optanium<br />

Catalog Number<br />

IOP-1P32-LW-SC<br />

IOP-1P32-SC<br />

IOP-1P32-HL-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-1S32-LW-SC<br />

IOP-1S32-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-3S32-LW-SC<br />

IOP-3S32-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-4S32-LW-SC<br />

IOP-4S32-SC<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

22 0.77 10<br />

25 0.87 10<br />

33 1.21 10<br />

26 0.90 10<br />

31 1.05 10<br />

39 1.38 10<br />

21 0.72 10<br />

25 0.88 10<br />

22 0.73 10<br />

26 0.88 10-15<br />

42 0.77 10<br />

48-47 0.87 10<br />

65-64 1.19 10<br />

47 0.86 10<br />

55-54 1.00 10<br />

74-73 1.31 10-15<br />

41-40 0.71 10<br />

49-48 0.88 10<br />

64-63 0.77 10<br />

72-71 0.87 10<br />

99-97 1.20 10<br />

69-68 0.85 10<br />

79-78 0.97 10<br />

107-106 1.24 10<br />

62-61 0.71 10<br />

72-71 0.89 10<br />

84-82 0.77 10<br />

96-94 0.87 10<br />

130-129 1.19 10<br />

80-79 0.71 10<br />

97-96 0.88 10<br />

Line<br />

Current<br />

(Amps)<br />

0.19-0.08<br />

0.22-0.10<br />

0.28-0.12<br />

0.22-0.10<br />

0.26-0.11<br />

0.33-0.15<br />

0.18-0.07<br />

0.20-0.09<br />

0.18-0.08<br />

0.21-0.09<br />

0.35-0.15<br />

0.41-0.18<br />

0.55-0.24<br />

0.40-0.18<br />

0.46-0.20<br />

0.62-0.27<br />

0.34-0.15<br />

0.41-0.18<br />

0.54-0.23<br />

0.61-0.26<br />

0.83-0.36<br />

0.58-0.25<br />

0.66-0.28<br />

0.90-0.39<br />

0.51-0.22<br />

0.60-0.26<br />

0.71-0.30<br />

0.81-0.35<br />

1.10-0.47<br />

0.67-0.29<br />

0.82-0.35<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

60/16<br />

60/16<br />

60/16<br />

60/16<br />

Dim.<br />

B<br />

B<br />

B<br />

G<br />

B<br />

B<br />

G<br />

B<br />

Wiring<br />

Dia.<br />

63<br />

*64<br />

20<br />

39<br />

64<br />

*65<br />

21<br />

65<br />

*66<br />

30<br />

66<br />

138<br />

ELECTRONIC<br />

FLUORESCENT<br />

Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />

Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />

See page 1-52 for Dimensions<br />

See page 1-57 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-53


T8/ES<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 30W - 48" Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

1<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

F32T8/ES (30W - 48")<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

RS<br />

Ballast<br />

Family<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Mark 5<br />

Standard<br />

Centium<br />

Catalog Number<br />

REL-1P32-LW-SC<br />

REL-1P32-SC<br />

REL-1P32-HL-SC<br />

REL-2P32-LW-SC<br />

REL-2P32-SC<br />

REL-2P32-HL-SC<br />

RCN-1S32-SC<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

VEL-1P32-LW-SC<br />

VEL-1P32-SC<br />

VEL-1P32-HL-SC<br />

VEL-2P32-LW-SC<br />

VEL-2P32-SC<br />

VEL-2P32-HL-SC<br />

VCN-1S32-SC<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

ICN-132-MC<br />

ICN-1P32-LW-SC<br />

ICN-1P32-SC<br />

ICN-2P32-LW-SC<br />

ICN-2P32-SC<br />

IOP-1P32-LW-SC<br />

IOP-1P32-SC<br />

IOP-1P32-HL-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-1S32-LW-SC<br />

IOP-1S32-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IIC-132-SC<br />

GEL-2P32-SC<br />

GEL-2P32-LW-RH-TP<br />

GCN-2P32<br />

GCN-1S32<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

28 0.75 20<br />

29 0.92 20<br />

39 1.20 20<br />

30 0.93 30<br />

35 1.10 25<br />

45 1.41 20<br />

32 0.90 10<br />

28 0.87 10<br />

33 1.01 10<br />

27 0.75 20<br />

29 0.92 20<br />

39 1.20 20<br />

30 0.93 30<br />

35 1.10 25<br />

45 1.41 20<br />

32 0.90 10<br />

28 0.87 15<br />

33 1.01 15<br />

27 0.88 10<br />

25 0.77 10<br />

29 0.90 10<br />

29-28 0.85 15-20<br />

33 1.03 10<br />

24 0.77 10<br />

27 0.87 10<br />

37-36 1.20 10<br />

28 0.90 10<br />

33 1.05 10<br />

42 1.38 10<br />

23 0.72 10<br />

27 0.88 10<br />

24-23 0.73 10<br />

27 0.90 10<br />

30 0.88 10<br />

36 1.10 20<br />

33 0.98 20<br />

35 1.10 10<br />

32 0.90 10<br />

Line<br />

Current<br />

(Amps)<br />

0.23<br />

0.25<br />

0.33<br />

0.28<br />

0.31<br />

0.38<br />

0.27<br />

0.24<br />

0.28<br />

0.10<br />

0.11<br />

0.14<br />

0.12<br />

0.13<br />

0.17<br />

0.12<br />

0.10<br />

0.12<br />

0.23-0.10<br />

0.21-0.09<br />

0.24-0.11<br />

0.24-0.11<br />

0.28-0.12<br />

0.20-0.09<br />

0.23-0.10<br />

0.31-0.13<br />

0.24-0.10<br />

0.28-0.12<br />

0.35-0.16<br />

0.19-0.08<br />

0.22-0.10<br />

0.20-0.09<br />

0.23-0.10<br />

0.26-0.11<br />

0.10<br />

0.10<br />

0.11<br />

0.09<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

60/16<br />

60/16<br />

60/16<br />

60/16<br />

Dim.<br />

B<br />

B<br />

A2<br />

B<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

63<br />

*64<br />

20<br />

*64<br />

63<br />

*64<br />

20<br />

*64<br />

63<br />

*64<br />

63<br />

*64<br />

20<br />

39<br />

20<br />

*64<br />

20<br />

Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />

Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />

See page 1-52 for Dimensions<br />

See page 1-57 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-54<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 30W - 48" Lamps<br />

T8/ES<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

2<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

F32T8/ES (30W - 48")<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

RS<br />

IS<br />

RS<br />

Ballast<br />

Family<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Mark 5<br />

Standard<br />

Centium<br />

Catalog Number<br />

REL-2P32-LW-SC<br />

REL-2P32-SC<br />

REL-2P32-HL-SC<br />

REL-3P32-LW-SC<br />

REL-3P32-SC<br />

REL-3P32-HL-SC<br />

RCN-2S32-SC<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

VEL-2P32-LW-SC<br />

VEL-2P32-SC<br />

VEL-2P32-HL-SC<br />

VEL-3P32-LW-SC<br />

VEL-3P32-SC<br />

VEL-3P32-HL-SC<br />

VCN-2S32-SC<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

ICN-2M32-MC<br />

ICN-2P32-LW-SC<br />

ICN-2P32-SC<br />

ICN-3P32-LW-SC<br />

ICN-3P32-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IIC-2S32-SC<br />

GEL-2P32-LW-RH-TP<br />

GEL-2P32-SC<br />

GEL-2S32-RH-TP<br />

GCN-2P32<br />

GCN-2S32<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

48 0.75 20<br />

54 0.87 20<br />

72 1.20 20<br />

54 0.87 20<br />

61 1.03 20<br />

80 1.32 20<br />

60 0.88 10<br />

45 0.78 10<br />

52 0.88 10<br />

51 0.85 10<br />

59 0.96 10<br />

48 0.75 20<br />

54 0.87 20<br />

72 1.20 20<br />

54 0.87 20<br />

61 1.03 20<br />

80 1.32 20<br />

60 0.88 10<br />

45 0.78 10<br />

52 0.88 10<br />

51 0.85 10<br />

58 0.96 10<br />

54 0.88 10<br />

47-46 0.77 10<br />

54 0.88 10<br />

52 0.83 10<br />

61 1.01 10<br />

45 0.77 10<br />

52-51 0.87 10<br />

72-70 1.19 10<br />

51 0.85 10<br />

59-58 1.00 10<br />

78-77 1.31 10<br />

44-43 0.71 10<br />

52 0.88 10<br />

57 0.88 10<br />

49 0.76 20<br />

56 0.88 20<br />

59 0.87 20<br />

55 0.90 10<br />

60 0.90 10<br />

Line<br />

Current<br />

(Amps)<br />

0.41<br />

0.46<br />

0.60<br />

0.45<br />

0.51<br />

0.67<br />

0.51<br />

0.38<br />

0.44<br />

0.43<br />

0.50<br />

0.18<br />

0.20<br />

0.26<br />

0.20<br />

0.22<br />

0.29<br />

0.22<br />

0.16<br />

0.19<br />

0.19<br />

0.21<br />

0.45-0.20<br />

0.39-0.17<br />

0.45-0.20<br />

0.44-0.19<br />

0.51-0.22<br />

0.38-0.17<br />

0.44-0.19<br />

0.60-0.26<br />

0.43-0.19<br />

0.50-0.21<br />

0.65-0.29<br />

0.36-0.16<br />

0.44-0.19<br />

0.49-0.21<br />

0.14<br />

0.17<br />

0.17<br />

0.16<br />

0.17<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

60/16<br />

60/16<br />

60/16<br />

60/16<br />

Dim.<br />

B<br />

B<br />

A2<br />

B<br />

A<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

64<br />

*65<br />

21<br />

64<br />

*65<br />

64<br />

*65<br />

21<br />

64<br />

*65<br />

64<br />

*65<br />

64<br />

*65<br />

21<br />

64<br />

21<br />

64<br />

21<br />

ELECTRONIC<br />

FLUORESCENT<br />

Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />

Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

See page 1-52 for Dimensions<br />

See page 1-57 for Wiring Diagrams<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-55


T8/ES<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 30W - 48" Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

3<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

F32T8/ES (30W - 48")<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

RS<br />

Ballast<br />

Family<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Mark 5<br />

Standard<br />

Centium<br />

Catalog Number<br />

REL-3P32-LW-SC<br />

REL-3P32-SC<br />

REL-3P32-HL-SC<br />

REL-4P32-LW-SC<br />

REL-4P32-SC<br />

RCN-3S32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

ROP-4P32-LW-SC<br />

ROP-4P32-SC<br />

VEL-3P32-LW-SC<br />

VEL-3P32-SC<br />

VEL-3P32-HL-SC<br />

VEL-4P32-LW-SC<br />

VEL-4P32-SC<br />

VCN-3S32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

VOP-4P32-LW-SC<br />

VOP-4P32-SC<br />

VOP-4P32-HL-90C<br />

ICN-3P32-LW-SC<br />

ICN-3P32-SC<br />

ICN-4P32-LW-SC<br />

ICN-4P32-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-3S32-LW-SC<br />

IOP-3S32-SC<br />

IIC-3S32-SC<br />

GEL-3P32-RH-TP<br />

GEL-4P32-LW<br />

GCN-3S32<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

70 0.75 20<br />

79 0.88 20<br />

105 1.18 20<br />

76 0.81 20<br />

87 1.00 20<br />

85 0.88 10<br />

51 0.85 10<br />

77 0.88 10<br />

73 0.83 10<br />

84 0.94 10<br />

70 0.75 20<br />

79 0.88 20<br />

105 1.18 20<br />

76 0.81 20<br />

87 1.00 20<br />

85 0.88 10<br />

66 0.78 10<br />

76 0.88 10<br />

73 0.83 10<br />

83 0.94 10<br />

110 1.25 10<br />

69-68 0.77 10<br />

79 0.88 10<br />

75-74 0.80 10<br />

87 1.00 10<br />

68-67 0.77 10<br />

77-76 0.87 10<br />

106-104 1.20 10<br />

75-74 0.84 10<br />

84-82 0.97 10<br />

115-114 1.24 10<br />

66-65 0.71 10<br />

77-76 0.88 10<br />

85 0.88 10<br />

90 0.97 20<br />

76 0.83 20<br />

89 0.89 10<br />

Line<br />

Current<br />

(Amps)<br />

0.58<br />

0.67<br />

0.88<br />

0.63<br />

0.73<br />

0.72<br />

0.43<br />

0.65<br />

0.61<br />

0.70<br />

0.25<br />

0.29<br />

0.38<br />

0.28<br />

0.32<br />

0.31<br />

0.24<br />

0.28<br />

0.27<br />

0.30<br />

0.40<br />

0.57-0.25<br />

0.66-0.29<br />

0.62-0.27<br />

0.73-0.32<br />

0.57-0.25<br />

0.65-0.28<br />

0.88-0.38<br />

0.63-0.27<br />

0.70-0.30<br />

0.97-0.42<br />

0.55-0.24<br />

0.64-0.28<br />

0.72-0.31<br />

0.26<br />

0.23<br />

0.26<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

60/16<br />

60/16<br />

60/16<br />

60/16<br />

Dim.<br />

B<br />

B<br />

B<br />

G<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

65<br />

*66<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

30<br />

Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />

Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />

See page 1-52 for Dimensions<br />

See page 1-57 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-56<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 30W - 48" Lamps<br />

T8/ES<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

F32T8/ES (30W - 48")<br />

4<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

Ballast<br />

Family<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Standard<br />

Catalog Number<br />

REL-4P32-LW-SC<br />

REL-4P32-SC<br />

RCN-4S32-SC<br />

ROP-4P32-LW-SC<br />

ROP-4P32-SC<br />

ROP-4P32-HL-90C<br />

VEL-4P32-LW-SC<br />

VEL-4P32-SC<br />

VCN-4S32-SC<br />

VOP-4P32-LW-SC<br />

VOP-4P32-SC<br />

VOP-4P32-HL-90C<br />

ICN-4P32-LW-SC<br />

ICN-4P32-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-4S32-LW-SC<br />

IOP-4S32-SC<br />

GEL-4P32-LW<br />

GEL-4P32-RH-TP<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

91 0.75 20<br />

104 0.88 20<br />

114 0.88 10<br />

89 0.78 10<br />

102 0.88 10<br />

133 1.18 10<br />

91 0.75 20<br />

104 0.88 20<br />

114 0.88 10<br />

73 0.83 10<br />

101 0.88 10<br />

132 1.18 10<br />

91-89 0.77 10<br />

105 0.88 10<br />

90-88 0.77 10<br />

102-100 0.87 10<br />

143-140 1.18 10<br />

86-84 0.71 10<br />

102-100 0.88 10<br />

90 0.76 20<br />

102 0.88 20<br />

Line<br />

Current<br />

(Amps)<br />

0.76<br />

0.87<br />

0.97<br />

0.75<br />

0.86<br />

1.12<br />

0.33<br />

0.38<br />

0.42<br />

0.32<br />

0.37<br />

0.48<br />

0.76-0.32<br />

0.88-0.38<br />

0.76-0.33<br />

0.86-0.37<br />

1.21-0.51<br />

0.71-0.31<br />

0.86-0.37<br />

0.26<br />

0.30<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

60/16<br />

60/16<br />

60/16<br />

60/16<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

G<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

66<br />

138<br />

66<br />

66<br />

138<br />

66<br />

66<br />

138<br />

66<br />

ELECTRONIC<br />

FLUORESCENT<br />

Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />

Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />

LAMP<br />

LAMP<br />

LAMP<br />

LINE<br />

RED<br />

RED<br />

BLUE/WHITE<br />

BLUE/WHITE<br />

BLACK<br />

WHITE<br />

LAMP<br />

BALLAST<br />

Diag. 30<br />

YELLOW<br />

YELLOW<br />

BLUE<br />

BLUE<br />

LINE<br />

* YEL<br />

BLUE<br />

* YEL<br />

BLUE<br />

BALLAST<br />

WHITE<br />

RED<br />

BLACK<br />

RED<br />

*FOR SINGLE LAMP OPERATION, INSULATE<br />

YELLOW LEADS INDIVIDUALLY FOR 600V<br />

Diag. 39<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

BLUE<br />

LINE<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

Diag. 63<br />

Diag. 64<br />

* For Single Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

LAMP<br />

Diag. 65<br />

* For Two Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

WHITE<br />

BLACK<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

LAMP<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

Diag. 66<br />

* For Three Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

Diag. 138<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

See page 1-52 for Dimensions<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-57


T8<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 32W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

1<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

PS<br />

RS<br />

IS<br />

IS<br />

PS<br />

RS<br />

IS<br />

IS<br />

PS<br />

IS<br />

RS<br />

Ballast<br />

Family<br />

F32T8, FBO31T8, F32T8/U6 (32W)<br />

AmbiStar ‡<br />

Standard<br />

Centium<br />

PowrKut<br />

Optanium<br />

Standard<br />

Centium<br />

PowrKut<br />

Optanium<br />

Centium<br />

Optanium<br />

Mark 5<br />

Standard<br />

Centium<br />

PowrKut<br />

Catalog Number<br />

REB-2P32-SC<br />

REL-1P32-LW-SC<br />

REL-1P32-SC<br />

REL-1P32-HL-SC<br />

REL-2P32-LW-SC<br />

REL-2P32-SC<br />

REL-2P32-HL-SC<br />

RCN-1S32-SC<br />

RK-132-TP<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

VEL-1P32-LW-SC<br />

VEL-1P32-SC<br />

VEL-1P32-HL-SC<br />

VEL-2P32-LW-SC<br />

VEL-2P32-SC<br />

VEL-2P32-HL-SC<br />

VCN-1S32-SC<br />

VK-132-TP<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

ICN-132-MC<br />

ICN-1P32-LW-SC<br />

ICN-1P32-SC<br />

ICN-2P32-LW-SC<br />

ICN-2P32-SC<br />

IOP-1P32-LW-SC<br />

IOP-1P32-SC<br />

IOP-1P32-HL-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-1S32-LW-SC<br />

IOP-1S32-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IIC-132-SC<br />

GEL-2P32-SC<br />

GCN-2P32<br />

GCN-1S32<br />

GK-132-TP<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

33 1.00 140<br />

29 0.75 20<br />

32 0.92 20<br />

41 1.20 20<br />

33 0.93 30<br />

38 1.10 25<br />

47 1.41 20<br />

34 0.90 10<br />

34 0.85 20<br />

30 0.87 10<br />

35 1.01 10<br />

29 0.75 20<br />

32 0.92 20<br />

41 1.20 20<br />

33 0.93 30<br />

38 1.10 25<br />

47 1.41 20<br />

34 0.90 10<br />

34 0.85 20<br />

30 0.87 15<br />

35 1.01 15<br />

30 0.88 10<br />

27 0.77 10<br />

31 0.90 10<br />

32 0.85 15-20<br />

36 1.03 15<br />

25 0.77 10<br />

28 0.87 10<br />

39-38 1.18 10<br />

31 0.90 10<br />

35 1.05 10<br />

45 1.37 10<br />

25 0.72 10<br />

28 0.88 10<br />

25 0.73 10<br />

29 0.90 10<br />

32 0.88 10<br />

38 1.10 25<br />

39 1.12 20<br />

34 0.87 10<br />

34 0.85 20<br />

Line<br />

Current<br />

(Amps)<br />

0.48<br />

0.24<br />

0.27<br />

0.35<br />

0.30<br />

0.34<br />

0.40<br />

0.29<br />

0.31<br />

0.25<br />

0.30<br />

0.11<br />

0.12<br />

0.15<br />

0.13<br />

0.15<br />

0.18<br />

0.13<br />

0.13<br />

0.11<br />

0.13<br />

0.25-0.11<br />

0.22-0.10<br />

0.26-0.12<br />

0.27-0.12<br />

0.30-0.14<br />

0.22-0.10<br />

0.25-0.11<br />

0.33-0.14<br />

0.26-0.11<br />

0.30-0.13<br />

0.37-0.17<br />

0.20-0.09<br />

0.24-0.10<br />

0.20-0.09<br />

0.24-0.11<br />

0.28-0.12<br />

0.12<br />

0.12<br />

0.10<br />

0.11<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

50/10<br />

0/-18<br />

0/-18<br />

32/0<br />

50/10<br />

0/-18<br />

0/-18<br />

0/-18<br />

32/0<br />

50/10<br />

Dim.<br />

B<br />

A<br />

B<br />

B<br />

A<br />

B<br />

A2<br />

B<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

*64<br />

63<br />

*64<br />

20<br />

*64<br />

63<br />

*64<br />

20<br />

*64<br />

63<br />

*64<br />

63<br />

*64<br />

20<br />

39<br />

20<br />

*64<br />

20<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

See page 1-52 for Dimensions<br />

See page 1-61 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-58<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 32W Lamps<br />

T8<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

2<br />

Input<br />

Volts<br />

120<br />

220<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

PS<br />

RS<br />

IS<br />

RS<br />

IS<br />

PS<br />

RS<br />

IS<br />

IS<br />

PS<br />

IS<br />

RS<br />

IS<br />

RS<br />

Ballast<br />

Family<br />

F32T8, FBO31T8, F32T8/U6 (32W)<br />

AmbiStar ‡<br />

Standard<br />

Centium<br />

PowrKut<br />

Optanium<br />

PowrKut<br />

Standard<br />

Centium<br />

PowrKut<br />

Optanium<br />

Centium<br />

Optanium<br />

Mark 5<br />

Standard<br />

Centium<br />

PowrKut<br />

Catalog Number<br />

REB-2P32-SC<br />

REL-2P32-LW-SC<br />

REL-2P32-SC<br />

REL-2P32-HL-SC<br />

REL-3P32-LW-SC<br />

REL-3P32-SC<br />

REL-3P32-HL-SC<br />

RCN-2S32-SC<br />

RK-2S32-TP<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

YK-2S32-TP<br />

VEL-2P32-LW-SC<br />

VEL-2P32-SC<br />

VEL-2P32-HL-SC<br />

VEL-3P32-LW-SC<br />

VEL-3P32-SC<br />

VEL-3P32-HL-SC<br />

VCN-2S32-SC<br />

VK-2S32-TP<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

ICN-2M32-MC<br />

ICN-2P32-LW-SC<br />

ICN-2P32-SC<br />

ICN-3P32-LW-SC<br />

ICN-3P32-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

IIC-2S32-SC<br />

GEL-2P32-LW-RH-TP<br />

GEL-2P32-SC<br />

GEL-2S32-RH-TP<br />

GCN-2P32<br />

GCN-2S32<br />

GK-2S32-TP<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

56 0.88 120<br />

51 0.75 20<br />

58 0.87 20<br />

77 1.20 20<br />

59 0.87 20<br />

65 1.03 20<br />

85 1.32 20<br />

63 0.88 10<br />

62 0.87 15<br />

48 0.78 10<br />

55 0.88 10<br />

54 0.85 10<br />

63 0.94 10<br />

63 0.87 15<br />

51 0.75 20<br />

58 0.87 20<br />

77 1.20 20<br />

59 0.87 20<br />

65 1.03 20<br />

85 1.32 20<br />

63 0.88 10<br />

62 0.87 15<br />

48 0.78 10<br />

55 0.88 10<br />

54 0.85 10<br />

62 0.94 10<br />

59 0.88 10<br />

50-49 0.77 10<br />

59 0.88 10<br />

57-56 0.86 10<br />

65 1.01 10<br />

48 0.77 10<br />

55-54 0.87 10<br />

74-72 1.18 10<br />

55-54 0.85 10<br />

63-62 1.00 10<br />

80-79 1.38 10<br />

47-46 0.71 10<br />

56-55 0.88 10<br />

61 0.88 10<br />

52 0.75 20<br />

59 0.87 20<br />

62 0.89 20<br />

59 0.90 10<br />

63 0.90 10<br />

63 0.89 15<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

Max.<br />

THD<br />

%<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

Line<br />

Current<br />

(Amps)<br />

0.80<br />

0.44<br />

0.49<br />

0.65<br />

0.49<br />

0.54<br />

0.71<br />

0.53<br />

0.56<br />

0.41<br />

0.47<br />

0.45<br />

0.53<br />

0.29<br />

0.19<br />

0.21<br />

0.28<br />

0.21<br />

0.24<br />

0.31<br />

0.23<br />

0.24<br />

0.17<br />

0.20<br />

0.20<br />

0.24<br />

0.50-0.21<br />

0.42-0.12<br />

0.49-0.22<br />

0.48-0.21<br />

0.54-0.24<br />

0.41-0.17<br />

0.47-0.20<br />

0.62-0.26<br />

0.46-0.20<br />

0.53-0.23<br />

0.67-0.29<br />

0.38-0.17<br />

0.47-0.20<br />

0.51-0.22<br />

0.15<br />

0.17<br />

0.18<br />

0.17<br />

0.18<br />

0.20<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

50/10<br />

0/-18<br />

50/10<br />

0/-18<br />

32/0<br />

50/10<br />

0/-18<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

32/0<br />

50/10<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A2<br />

B<br />

A<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

64<br />

*65<br />

21<br />

64<br />

*65<br />

21<br />

64<br />

*65<br />

21<br />

64<br />

*65<br />

64<br />

*65<br />

64<br />

*65<br />

21<br />

64<br />

21<br />

64<br />

21<br />

See page 1-52 for Dimensions<br />

See page 1-61 for Wiring Diagrams<br />

ELECTRONIC<br />

FLUORESCENT<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-59


T8<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 32W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

3<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

RS<br />

Ballast<br />

Family<br />

F32T8, FBO31T8, F32T8/U6 (32W)<br />

AmbiStar ‡<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Mark 5<br />

Standard<br />

Centium<br />

Catalog Number<br />

REB-4P32-SC<br />

REL-3P32-LW-SC<br />

REL-3P32-SC<br />

REL-3P32-HL-SC<br />

REL-4P32-LW-SC<br />

REL-4P32-SC<br />

RCN-3S32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

ROP-4P32-LW-SC<br />

ROP-4P32-SC<br />

ROP-4P32-HL-90C<br />

VEL-3P32-LW-SC<br />

VEL-3P32-SC<br />

VEL-3P32-HL-SC<br />

VEL-4P32-LW-SC<br />

VEL-4P32-SC<br />

VCN-3S32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

VOP-4P32-LW-SC<br />

VOP-4P32-SC<br />

VOP-4P32-HL-90C<br />

ICN-3P32-LW-SC<br />

ICN-3P32-SC<br />

ICN-4P32-LW-SC<br />

ICN-4P32-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-3S32-LW-SC<br />

IOP-3S32-SC<br />

IIC-3S32-SC<br />

GEL-3P32-RH-TP<br />

GEL-4P32-LW<br />

GCN-3S32<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

80 0.84 125<br />

76 0.75 20<br />

85 0.88 20<br />

111 1.19 20<br />

82 0.81 20<br />

94 1.00 20<br />

91 0.88 10<br />

73 0.78 10<br />

83 0.88 10<br />

78 0.82 10<br />

89 0.92 10<br />

119 1.20 10<br />

76 0.75 20<br />

85 0.88 20<br />

111 1.19 20<br />

82 0.81 20<br />

94 1.00 20<br />

91 0.88 10<br />

73 0.78 10<br />

82 0.88 10<br />

78 0.82 10<br />

89 0.92 10<br />

117 1.25 10<br />

74-73 0.77 10<br />

85 0.88 10<br />

80-79 0.82 10<br />

93 1.00 10<br />

73-71 0.77 10<br />

82-80 0.87 10<br />

110-707 1.18 10<br />

80-79 0.84 10<br />

90-88 0.97 10<br />

120-119 1.26 10<br />

71-70 0.71 10<br />

83-81 0.88 10<br />

91 0.88 10<br />

90 0.97 20<br />

82 0.81 25<br />

94 0.92 10<br />

Line<br />

Current<br />

(Amps)<br />

1.36<br />

0.64<br />

0.71<br />

0.93<br />

0.69<br />

0.79<br />

0.78<br />

0.61<br />

0.70<br />

0.65<br />

0.75<br />

0.99<br />

0.27<br />

0.31<br />

0.40<br />

0.29<br />

0.34<br />

0.34<br />

0.27<br />

0.30<br />

0.29<br />

0.33<br />

0.43<br />

0.62-0.27<br />

0.88-0.88<br />

0.67-0.29<br />

0.78-0.33<br />

0.62-0.27<br />

0.70-0.30<br />

0.91-0.39<br />

0.67-0.29<br />

0.75-0.32<br />

1.02-0.44<br />

0.59-0.21<br />

0.70-0.30<br />

0.76-0.32<br />

0.26<br />

0.24<br />

0.28<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

0/-18<br />

32/0<br />

Dim.<br />

B<br />

B<br />

B<br />

G<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

*66<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

65<br />

*66<br />

65<br />

*66<br />

30<br />

65<br />

*66<br />

30<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

See page 1-52 for Dimensions<br />

See page 1-61 for Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-60<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 32W Lamps<br />

T8<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

F32T8, FBO31T8, F32T8/U6 (32W)<br />

AmbiStar ‡<br />

IS<br />

Standard<br />

120 PS Centium<br />

4<br />

Input<br />

Volts<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

PS<br />

IS<br />

Ballast<br />

Family<br />

Optanium<br />

Standard<br />

Centium<br />

Optanium<br />

Centium<br />

Optanium<br />

Standard<br />

Catalog Number<br />

REB-4P32-SC<br />

REL-4P32-LW-SC<br />

REL-4P32-SC<br />

RCN-4S32-SC<br />

ROP-4P32-LW-SC<br />

ROP-4P32-SC<br />

ROP-4P32-HL-90C<br />

VEL-4P32-LW-SC<br />

VEL-4P32-SC<br />

VCN-4S32-SC<br />

VOP-4P32-LW-SC<br />

VOP-4P32-SC<br />

VOP-4P32-HL-90C<br />

ICN-4P32-LW-SC<br />

ICN-4P32-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

IOP-4S32-LW-SC<br />

IOP-4S32-SC<br />

GEL-4P32-LW<br />

GEL-4P32-RH-TP<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

103 0.81 125<br />

98 0.75 20<br />

112 0.88 20<br />

121 0.88 10<br />

96 0.78 10<br />

108 0.88 10<br />

146 1.18 10<br />

98 0.75 20<br />

112 0.88 20<br />

121 0.88 10<br />

95 0.78 10<br />

107 0.88 10<br />

143 1.18 10<br />

97-95 0.77 10<br />

112 0.88 10<br />

96-94 0.77 10<br />

109-106 0.87 10<br />

146-143 1.18 10<br />

93-91 0.71 10<br />

110 0.88 10<br />

98 0.75 20<br />

112 0.85 20<br />

Line<br />

Current<br />

(Amps)<br />

1.57<br />

0.82<br />

0.94<br />

1.03<br />

0.81<br />

0.91<br />

1.22<br />

0.36<br />

0.41<br />

0.45<br />

0.35<br />

0.39<br />

0.52<br />

0.81-0.34<br />

0.94-0.41<br />

0.81-0.35<br />

0.92-0.39<br />

1.23-0.53<br />

0.77-0.33<br />

0.92-0.40<br />

0.29<br />

0.31<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

32/0<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

G<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

66<br />

138<br />

66<br />

66<br />

138<br />

66<br />

66<br />

138<br />

66<br />

ELECTRONIC<br />

FLUORESCENT<br />

‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />

LAMP<br />

LAMP<br />

LAMP<br />

LAMP<br />

LINE<br />

RED<br />

RED<br />

BLUE/WHITE<br />

BLUE/WHITE<br />

BLACK<br />

WHITE<br />

BALLAST<br />

Diag. 30<br />

YELLOW<br />

YELLOW<br />

BLUE<br />

BLUE<br />

LINE<br />

* YEL<br />

BLUE<br />

* YEL<br />

BLUE<br />

BALLAST<br />

WHITE<br />

RED<br />

BLACK<br />

RED<br />

*FOR SINGLE LAMP OPERATION, INSULATE<br />

YELLOW LEADS INDIVIDUALLY FOR 600V<br />

Diag. 39<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

BLUE<br />

LINE<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

Diag. 63<br />

Diag. 64<br />

* For Single Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

LAMP<br />

Diag. 65<br />

* For Two Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

WHITE<br />

BLACK<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

LAMP<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

Diag. 66<br />

* For Three Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

Diag. 138<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

See page 1-52 for Dimensions<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-61


T8<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 40W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

1<br />

2<br />

Input<br />

Volts<br />

F40T8 (40W)<br />

120<br />

277<br />

120-277<br />

120<br />

277<br />

120-277<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

IS<br />

IS<br />

PS<br />

IS<br />

IS<br />

IS<br />

Ballast<br />

Family<br />

Standard<br />

Optanium<br />

Standard<br />

Optanium<br />

Centium<br />

Optanium<br />

Standard<br />

Optanium<br />

Standard<br />

Optanium<br />

Centium<br />

Optanium<br />

Catalog Number<br />

REL-1P32-HL-SC<br />

REL-2P32-LW-SC<br />

REL-2P32-HL-SC<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

VEL-1P32-HL-SC<br />

VEL-2P32-LW-SC<br />

VEL-2P32-HL-SC<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

ICN-2P32-LW-SC<br />

ICN-2P32-SC<br />

IOP-2P32-LW-SC<br />

IOP-2P32-SC<br />

IOP-2P32-HL-SC<br />

IOP-2S32-LW-SC<br />

IOP-2S32-SC<br />

REL-3P32-LW-SC<br />

REL-3P32-SC<br />

REL-3P32-HL-SC<br />

ROP-2P32-LW-SC<br />

ROP-2P32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

VEL-3P32-LW-SC<br />

VEL-3P32-SC<br />

VEL-3P32-HL-SC<br />

VOP-2P32-LW-SC<br />

VOP-2P32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

ICN-3P32-LW-SC<br />

ICN-3P32-SC<br />

IOP-3P32-LW-SC<br />

IOP-3P32-SC<br />

IOP-3P32-HL-90C-SC<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

49 1.06 20<br />

39 0.88 25<br />

58 1.38 20<br />

35 0.87 10<br />

41 1.01 10<br />

49 1.16 20<br />

39 0.88 25<br />

58 1.38 20<br />

35 0.87 15<br />

41 1.01 15<br />

37 0.86 10-15<br />

42 1.00 10<br />

35 0.87 10<br />

41 1.01 10<br />

55-54 1.35 10<br />

31-30 0.73 10<br />

36 0.90 10<br />

70 0.86 20<br />

79 1.01 20<br />

103 1.30 20<br />

58 0.78 10<br />

067 0.88 10<br />

66 0.83 10<br />

75 0.95 10<br />

70 0.86 20<br />

79 1.01 15<br />

103 1.30 20<br />

58 0.78 10<br />

67 0.88 10<br />

66 0.83 10<br />

74 0.95 10<br />

69-67 0.83 10<br />

77 1.00 10<br />

67-66 0.85 10<br />

74-72 1.01 10<br />

102-100 1.30 10<br />

Line<br />

Current<br />

(Amps)<br />

0.41<br />

0.34<br />

0.49<br />

0.30<br />

0.35<br />

0.18<br />

0.15<br />

0.21<br />

0.13<br />

0.15<br />

0.31-0.14<br />

0.35-0.15<br />

0.29-0.13<br />

0.35-0.15<br />

0.46-0.20<br />

0.73-0.11<br />

0.30-0.13<br />

0.59<br />

0.66<br />

0.86<br />

0.49<br />

0.56<br />

0.56<br />

0.64<br />

0.26<br />

0.31<br />

0.37<br />

0.22<br />

0.24<br />

0.24<br />

0.27<br />

0.58-0.25<br />

0.65-0.28<br />

0.58-0.25<br />

0.64-0.27<br />

0.85-0.37<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

0/-18<br />

Dim.<br />

B<br />

B<br />

B<br />

B<br />

B<br />

B<br />

Wiring<br />

Dia.<br />

63<br />

*64<br />

63<br />

*64<br />

*64<br />

39<br />

*65<br />

64<br />

*65<br />

*65<br />

64<br />

*65<br />

*65<br />

See page 1-63 for Dimensions and Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-62<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 40W Lamps<br />

T8<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

F40T8 (40W)<br />

3<br />

4<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

120<br />

277<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

IS<br />

IS<br />

IS<br />

IS<br />

Ballast<br />

Family<br />

Standard<br />

Optanium<br />

Standard<br />

Optanium<br />

Centium<br />

Optanium<br />

Standard<br />

Optanium<br />

Catalog Number<br />

REL-4P32-LW-SC<br />

REL-4P32-SC<br />

ROP-3P32-LW-SC<br />

ROP-3P32-SC<br />

ROP-4P32-LW-SC<br />

ROP-4P32-SC<br />

ROP-4P32-HL-90C<br />

VEL-4P32-LW-SC<br />

VEL-4P32-SC<br />

VOP-3P32-LW-SC<br />

VOP-3P32-SC<br />

VOP-4P32-LW-SC<br />

VOP-4P32-SC<br />

VOP-4P32-HL-90C<br />

ICN-4P32-LW-SC<br />

ICN-4P32-SC<br />

IOP-4P32-LW-SC<br />

IOP-4P32-SC<br />

IOP-4P32-HL-90C-G<br />

GEL-3P32-RH-TP<br />

GEL-4P32-LW<br />

GEL-4P32-RH-TP<br />

ROP-4P32-LW-SC<br />

VOP-4P32-LW-SC<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

98 0.81 20<br />

112 0.88 20<br />

88 0.78 10<br />

102 0.95 10<br />

95 0.82 10<br />

81 1.03 10<br />

155 1.25 10<br />

98 0.81 20<br />

112 0.88 15<br />

88 0.78 10<br />

101 0.88 10<br />

95 0.82 10<br />

108 0.93 10<br />

151 1.25 10<br />

97-95 0.82 10<br />

112 0.97 10<br />

98-96 0.84 10<br />

110-107 0.93 10<br />

150-147 1.25 10<br />

107 0.89 20<br />

98 0.81 25<br />

108 0.89 20<br />

116 0.89 10<br />

116 0.89 10<br />

Line<br />

Current<br />

(Amps)<br />

0.82<br />

0.94<br />

0.73<br />

0.64<br />

0.80<br />

0.69<br />

1.30<br />

0.35<br />

0.41<br />

0.32<br />

0.37<br />

0.35<br />

0.38<br />

0.55<br />

0.81-0.34<br />

0.94-0.40<br />

0.82-0.35<br />

0.92-0.38<br />

1.27-0.54<br />

0.32<br />

0.29<br />

0.32<br />

0.98<br />

0.41<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

32/0<br />

32/0<br />

32/0<br />

32/0<br />

32/0<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

G<br />

A<br />

B<br />

Wiring<br />

Dia.<br />

*66<br />

65<br />

*66<br />

*66<br />

65<br />

*66<br />

*66<br />

65<br />

*66<br />

66<br />

ELECTRONIC<br />

FLUORESCENT<br />

Fig. A<br />

1.18"<br />

1.7"<br />

8.90"<br />

9.5"<br />

Fig. B<br />

Fig. G<br />

LAMP<br />

LINE<br />

* YEL<br />

* YEL<br />

WHITE<br />

BLACK<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

LAMP<br />

BLUE<br />

BLUE<br />

BLUE<br />

*FOR SINGLE LAMP OPERATION, INSULATE<br />

YELLOW LEADS INDIVIDUALLY FOR 600V<br />

Diag. 39<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

LINE<br />

LAMP<br />

LAMP<br />

Diag. 65<br />

LINE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

LAMP<br />

Diag. 63<br />

BLUE<br />

Diag. 64<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

LINE<br />

LAMP<br />

LAMP<br />

* For Single Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

* For Two Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

LINE<br />

WHITE<br />

BLACK<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

LAMP<br />

LAMP<br />

LAMP<br />

LAMP<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

Diag. 66<br />

* For Three Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-63


T8 Slimline<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 46 - 59W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

F72T8 (46W)<br />

120<br />

1 277<br />

120-277<br />

120<br />

2 277<br />

120-277<br />

F96T8/ES (57W)<br />

1<br />

2<br />

120<br />

277<br />

120-277<br />

347<br />

120<br />

277<br />

120-277<br />

347<br />

F96T8 (59W)<br />

1<br />

2<br />

Input<br />

Volts<br />

120<br />

277<br />

120-277<br />

347<br />

120<br />

277<br />

120-277<br />

347<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

IS<br />

IS<br />

IS<br />

IS<br />

IS<br />

Ballast<br />

Family<br />

Standard<br />

Centium<br />

Standard<br />

Centium<br />

REL-2P59-SC<br />

VEL-2P59-SC<br />

IOP-2P59-SC<br />

REL-2P59-SC<br />

VEL-2P59-SC<br />

IOP-2P59-SC<br />

58<br />

54<br />

90<br />

88<br />

Standard<br />

Centium<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Standard<br />

Centium<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Standard<br />

Centium<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Standard<br />

Centium<br />

Standard<br />

Centium<br />

Optanium<br />

Standard<br />

Catalog Number<br />

REL-2P59-S-RH-TP<br />

REL-2P59-SC<br />

RCN-2P59<br />

VEL-2P59-S-RH-TP<br />

VEL-2P59-SC<br />

VCN-2P59<br />

IOP-2P59-SC<br />

GEL-2P59<br />

REL-2P59-S-RH-TP<br />

REL-2P59-SC<br />

RCN-2P59<br />

VEL-2P59-S-RH-TP<br />

VEL-2P59-SC<br />

VCN-2P59<br />

IOP-2P59-SC<br />

GEL-2P59<br />

REL-2P59-S-RH-TP<br />

REL-2P59-SC<br />

RCN-2P59<br />

VEL-2P59-S-RH-TP<br />

VEL-2P59-SC<br />

VCN-2P59<br />

IOP-2P59-SC<br />

GEL-2P59<br />

REL-2P59-S-RH-TP<br />

REL-2P59-SC<br />

RCN-2P59<br />

VEL-2P59-S-RH-TP<br />

VEL-2P59-SC<br />

VCN-2P59<br />

IOP-2P59-SC<br />

GEL-2P59<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

1.15 20<br />

1.09 10<br />

0.90<br />

0.92<br />

Max.<br />

THD<br />

%<br />

20<br />

10<br />

68 1.10 30<br />

69 1.05 20<br />

68 1.10 30<br />

69 1.05 20<br />

64 1.05 10<br />

70 1.10 30<br />

106 0.85 20<br />

106 0.88 10<br />

106 0.85 20<br />

106 0.88 10<br />

103 0.87 10<br />

108 0.88 20<br />

70 1.10 30<br />

71 1.05 20<br />

70 1.10 30<br />

71 1.05 20<br />

67 1.05 10<br />

72 1.10 30<br />

110 0.85 20<br />

110 0.88 10<br />

110 0.85 20<br />

110 0.88 10<br />

107 0.87 10<br />

110 0.88 20<br />

Line<br />

Current<br />

(Amps)<br />

0.54<br />

0.23<br />

0.46-0.20<br />

0.79<br />

0.34<br />

0.74-0.32<br />

0.60<br />

0.63<br />

0.26<br />

0.26<br />

0.56-0.25<br />

0.21<br />

0.90<br />

0.90<br />

0.39<br />

0.39<br />

0.86-0.37<br />

0.32<br />

0.62<br />

0.63<br />

0.27<br />

0.27<br />

0.56-0.25<br />

0.22<br />

0.94<br />

0.94<br />

0.41<br />

0.41<br />

0.91-0.39<br />

0.32<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

32/0<br />

32/0<br />

32/0<br />

32/0<br />

32/0<br />

32/0<br />

Dim.<br />

B<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

A<br />

B<br />

A<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

*64<br />

64<br />

*64<br />

64<br />

*64<br />

64<br />

• RCN and VCN ballasts will be phased out in 2006 and replaced by IOP-2P59-SC.<br />

• REL and VEL “Standard can” ballasts will be phased out in 2006 and replaced by “Small can” ballasts.<br />

See page 1-63 for Dimensions and Wiring Diagrams<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-64<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 44 - 86W Lamps<br />

T8/HO<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

F48T8/HO (44W)<br />

1 120-277<br />

2 120-277<br />

F60T8/HO (55W)<br />

1 120-277<br />

2 120-277<br />

F72T8/HO (65W)<br />

1 120-277<br />

120<br />

2 277<br />

120-277<br />

F96T8/HO (86W)<br />

1 120-277<br />

120<br />

2 277<br />

120-277<br />

Lamp<br />

Starting<br />

Method<br />

PS<br />

PS<br />

Ballast<br />

Family<br />

Centium<br />

Centium<br />

Catalog Number<br />

ICN-2S86<br />

ICN-2S86<br />

ICN-2S86<br />

ICN-2S86<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

59 1.02 20<br />

98 0.95 10<br />

70 1.00 20<br />

118 0.92 10<br />

Line<br />

Current<br />

(Amps)<br />

0.50-0.23<br />

0.84-0.36<br />

0.58-0.26<br />

1.04-0.45<br />

PS Centium ICN-2S86<br />

81 1.00 15 0.68-0.30<br />

REL-2S86<br />

1.11<br />

RS Standard<br />

130 0.92 20<br />

VEL-2S86<br />

0.48<br />

PS Centium ICN-2S86<br />

140 0.94 10 1.21-0.54<br />

PS Centium ICN-2S86<br />

100 1.00 10 0.84-0.36<br />

REL-2S86<br />

1.36<br />

RS Standard<br />

160 0.88 20<br />

VEL-2S86<br />

0.60<br />

PS Centium ICN-2S86<br />

185 0.95 10 1.57-0.68<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

-20/-29<br />

-20/-29<br />

-20/-29<br />

50/10<br />

-20/-29<br />

-20/-29<br />

50/10<br />

-20/-29<br />

Dim.<br />

C<br />

C<br />

C<br />

C<br />

Wiring<br />

Dia.<br />

39A<br />

21<br />

39A<br />

21<br />

39A<br />

21<br />

39A<br />

21<br />

ELECTRONIC<br />

FLUORESCENT<br />

1 25 /32”<br />

2 7 /8”<br />

11 3 /4”<br />

11 9 /64”<br />

Slimline Fig. Cand HO<br />

LAMP<br />

LINE<br />

BLACK<br />

WHITE<br />

YEL<br />

YEL<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

Diag. 39A<br />

For single lamp operation insulate<br />

yellow leads individually for 1000V<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-65


T10 and T12<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 25 - 40W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

F40T10 (40W)<br />

1<br />

120<br />

277<br />

120<br />

2 277<br />

347<br />

RS<br />

3<br />

120<br />

277<br />

F25T12 (25W - 36")<br />

1<br />

120<br />

277<br />

2<br />

120<br />

277<br />

RS<br />

3<br />

120<br />

277<br />

F30T12 (30W - 36")<br />

1<br />

120<br />

277<br />

2<br />

120<br />

277<br />

RS<br />

3<br />

120<br />

277<br />

Ballast<br />

Family<br />

Standard<br />

Standard<br />

Standard<br />

Catalog Number<br />

REL-1S40-SC<br />

VEL-1S40-SC<br />

REL-2S40-SC<br />

VEL-2S40-SC<br />

GEL-2S40-RH-TP<br />

REL-3S40-RH-TP<br />

VEL-3S40-RH-TP<br />

REL-1S40-SC<br />

VEL-1S40-SC<br />

REL-2S40-SC<br />

VEL-2S40-SC<br />

REL-3S40-RH-TP<br />

VEL-3S40-RH-TP<br />

REL-1S40-SC<br />

VEL-1S40-SC<br />

REL-2S40-SC<br />

VEL-2S40-SC<br />

REL-3S40-RH-TP<br />

VEL-3S40-RH-TP<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

35<br />

71<br />

72<br />

112<br />

28<br />

50<br />

80<br />

30<br />

60<br />

90<br />

Ballast<br />

Factor<br />

0.85<br />

0.85<br />

0.87<br />

0.85<br />

1.07<br />

1.01<br />

0.95<br />

0.98<br />

0.92<br />

0.95<br />

Max.<br />

THD<br />

%<br />

20<br />

20<br />

20<br />

Line<br />

Current<br />

(Amps)<br />

0.30<br />

0.13<br />

0.62<br />

0.25<br />

0.21<br />

0.95<br />

0.41<br />

0.24<br />

0.10<br />

0.44<br />

0.18<br />

0.69<br />

0.30<br />

0.27<br />

0.12<br />

0.51<br />

0.22<br />

0.78<br />

0.34<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

50/10<br />

50/10<br />

50/10<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

20<br />

21<br />

30<br />

20<br />

21<br />

30<br />

20<br />

21<br />

30<br />

LAMP<br />

LAMP<br />

LAMP<br />

LINE<br />

RED<br />

RED<br />

BLUE/WHITE<br />

BLUE/WHITE<br />

BLACK<br />

WHITE<br />

BALLAST<br />

Diag. 30<br />

YELLOW<br />

YELLOW<br />

BLUE<br />

BLUE<br />

See page 1-67 for Dimensions<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-66<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 22 - 40W Lamps<br />

T10 and T12<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

F34T12, F34T12/U (34W)<br />

120<br />

1<br />

277<br />

Standard<br />

120<br />

AmbiStar<br />

PowrKut<br />

2<br />

RS<br />

Standard<br />

277<br />

PowrKut<br />

347<br />

120<br />

Standard<br />

3<br />

277<br />

F40T12, F40T12/U (40W)<br />

120<br />

1<br />

277<br />

Standard<br />

2<br />

3<br />

Input<br />

Volts<br />

120<br />

277<br />

347<br />

120<br />

277<br />

Lamp<br />

Starting<br />

Method<br />

RS<br />

Ballast<br />

Family<br />

AmbiStar<br />

PowrKut<br />

Standard<br />

PowrKut<br />

Standard<br />

Catalog Number<br />

REL-1S40-SC<br />

VEL-1S40-SC<br />

REL-2S40-SC<br />

RELB-2S40-SC<br />

RK-2S34-TP**<br />

VEL-2S40-SC<br />

VK-2S34-TP**<br />

GEL-2S40-RH-TP<br />

REL-3S40-RH-TP<br />

VEL-3S40-RH-TP<br />

REL-1S40-SC<br />

VEL-1S40-SC<br />

REL-2S40-SC<br />

RELB-2S40-SC<br />

RK-2S34-TP**<br />

VEL-2S40-SC<br />

VK-2S34-TP**<br />

GEL-2S40-RH-TP<br />

REL-3S40-RH-TP<br />

VEL-3S40-RH-TP<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

31<br />

60<br />

62<br />

60<br />

60<br />

60<br />

62<br />

91<br />

35<br />

71<br />

73<br />

68<br />

71<br />

68<br />

72<br />

107<br />

Ballast<br />

Factor<br />

0.88<br />

0.85<br />

0.85<br />

0.80<br />

0.85<br />

0.80<br />

0.87<br />

0.87<br />

0.85<br />

0.85<br />

0.85<br />

0.82<br />

0.85<br />

0.82<br />

0.87<br />

0.87<br />

Max.<br />

THD<br />

%<br />

20<br />

20<br />

Line<br />

Current<br />

(Amps)<br />

0.27<br />

0.12<br />

0.52<br />

0.53<br />

0.52<br />

0.22<br />

0.22<br />

0.18<br />

0.77<br />

0.33<br />

0.30<br />

0.13<br />

0.62<br />

0.62<br />

0.57<br />

0.25<br />

0.25<br />

0.21<br />

0.91<br />

0.39<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

50/10<br />

50/10<br />

Dim.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

Wiring<br />

Dia.<br />

20<br />

21<br />

30<br />

20<br />

21<br />

30<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

FC8T9 (22W Circline)<br />

1 120 IS Matchbox † RMB-1P26-S2 22 0.95 150 0.35 0/-18 S2 163<br />

† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />

**For replacement use only.<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

S2 Model<br />

Fig. A<br />

1.18"<br />

8.90"<br />

9.5"<br />

1.7"<br />

Fig. B<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

See page 1-66 for Wiring Diagrams<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-67


T12 Slimline<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 55 - 75W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

ELECTRONIC<br />

FLUORESCENT<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

F72T12 (55W)<br />

120<br />

1<br />

277<br />

120<br />

2<br />

277<br />

F96T12/ES (60W)<br />

120<br />

1<br />

277<br />

120<br />

2<br />

277<br />

F96T12 (75W)<br />

120<br />

1<br />

277<br />

120<br />

2<br />

277<br />

Lamp<br />

Starting<br />

Method<br />

IS<br />

IS<br />

IS<br />

Ballast<br />

Family<br />

Standard<br />

Standard<br />

Standard<br />

Catalog Number<br />

REL-2P60-S<br />

VEL-2P75-S<br />

REL-2P60-S<br />

VEL-2P75-S<br />

REL-2P60-S<br />

VEL-2P75-S<br />

REL-2P60-S<br />

VEL-2P75-S<br />

REL-2P60-S<br />

VEL-2P75-S<br />

REL-2P60-S<br />

VEL-2P75-S<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

70<br />

110<br />

70<br />

107<br />

85<br />

132<br />

Ballast<br />

Factor<br />

1.10<br />

0.92<br />

1.05<br />

0.85<br />

1.05<br />

0.85<br />

Max.<br />

THD<br />

%<br />

30<br />

20<br />

30<br />

20<br />

30<br />

20<br />

Line<br />

Current<br />

(Amps)<br />

0.62<br />

0.27<br />

0.93<br />

0.41<br />

0.62<br />

0.27<br />

0.88<br />

0.39<br />

0.75<br />

0.32<br />

1.13<br />

0.49<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

-20/-29<br />

-20/-29<br />

-20/-29<br />

Dim.<br />

C<br />

C<br />

C<br />

Wiring<br />

Dia.<br />

*64<br />

64<br />

*64<br />

64<br />

*64<br />

64<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

1 25 /32”<br />

LAMP<br />

LINE<br />

LAMP<br />

2 7 /8”<br />

11 3 /4”<br />

11 9 /64”<br />

Slimline Fig. Cand HO<br />

Diag. 64<br />

* For Single Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

1-68<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 60 - 110W Lamps<br />

T12/HO<br />

HIGH POWER FACTOR<br />

SOUND RATED B<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

F48T12/HO (60W)<br />

120<br />

REL-2S110<br />

1.09<br />

2 RS Standard<br />

125 1.15 30<br />

-20/-29 C 21<br />

277<br />

VEL-2S110<br />

0.48<br />

F60T12/HO (75W)<br />

120<br />

REL-2S110<br />

1.29<br />

2 RS Standard 145 1.00 30<br />

-20/-29 C 21<br />

277<br />

VEL-2S110<br />

0.53<br />

F72T12/HO (85W)<br />

120<br />

REL-2S110<br />

1.40<br />

2 RS Standard 164 0.90 20<br />

-20/-29 C 21<br />

277<br />

VEL-2S110<br />

0.61<br />

F96T12/HO/ES (95W)<br />

120<br />

REL-2S110<br />

1.44<br />

2 RS Standard 170 0.89 20<br />

-20/-29 C 21<br />

277<br />

VEL-2S110<br />

0.63<br />

F96T12/HO (110W)<br />

120<br />

REL-2S110<br />

1.10<br />

1<br />

119 0.91 30<br />

39A<br />

277<br />

VEL-2S110<br />

0.48<br />

RS Standard<br />

-20/-29 C<br />

120<br />

REL-2S110<br />

1.74<br />

2<br />

205 0.89 20<br />

21<br />

277<br />

VEL-2S110<br />

0.76<br />

Max.<br />

THD<br />

%<br />

Dim.<br />

Wiring<br />

Dia.<br />

ELECTRONIC<br />

FLUORESCENT<br />

1 25 /32”<br />

2 7 /8”<br />

11 3 /4”<br />

11 9 /64”<br />

Slimline Fig. Cand HO<br />

LAMP<br />

LINE<br />

BLACK<br />

WHITE<br />

YEL<br />

YEL<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

Diag. 39A<br />

For single lamp operation insulate<br />

yellow leads individually for 1000V<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

1-69


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

NOTES<br />

ELECTRONIC<br />

FLUORESCENT<br />

1-70<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Contents<br />

Optanium Step-Dim . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 to 2-3<br />

AmbiStar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 to 2-5<br />

Mark 10 Powerline . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 to 2-10<br />

Mark 7 0-10V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11 to 2-16<br />

ROVR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 to 2-21<br />

Compatible Controls . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22 to 2-23<br />

CONTROLLABLE<br />

Select the control you need for your application from a list of manufacturers<br />

that offer compatible controls for the Mark 7 0-10V and<br />

Mark 10 Powerline electronic dimming ballasts, as well as, ROVR digital<br />

addressable ballasts. The manufacturers that offer Mark 10 Powerline<br />

controls have built the control according to our specifications to<br />

assure the system is compatible. Part numbers and/or brands are<br />

listed along with the manufacturer’s phone number.<br />

Note: Refer to pages 8-24 to 8-26 for Ballast specifications.<br />

Corporate Offices<br />

(800) 322-2086<br />

Customer Support/Technical Service<br />

(800) 372-3331 • (+) 1 847 390-5000 (International)<br />

Visit our web site at www.advancetransformer.com<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 2-1


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Optanium ® Step-Dim<br />

High-efficiency electronic ballasts for a T5 lighting systems<br />

Versatile and high-performing, <strong>Advance</strong>'s Optanium ® high-efficiency electronic ballasts optimize<br />

energy savings and are compatible with T5 high efficiency lamps.<br />

STEP DIMMING<br />

<strong>Advance</strong>'s Optanium family optimizes lumen-per-watt performance and delivers a high-efficiency<br />

solution for a broad range of commercial, industrial, and institutional applications.<br />

OPTANIUM<br />

Features<br />

Benefits<br />

Stepped-Dim capable<br />

Energy consumption reduced by 50%<br />

End-of-lamp-life protection<br />

Safely removes power to the lamp(s)<br />

Lamp auto-restrike circuitry and anti-arcing These and other standard features within the Optanium 2.0<br />

technology<br />

line reduce maintenance concerns and enhance safety<br />

PLUS 90 Protection ®<br />

<strong>Advance</strong>'s exclusive extended system warranty protection,<br />

which matches any lamp manufacturer's published lampballast<br />

system warranty, plus adds 90 days of additional<br />

warranty protection—on both the lamp and ballast!<br />

2-2<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 28W Lamps<br />

T5<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Optanium <strong>Electronic</strong> Step-Dim Ballast<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F28T5 (28W)<br />

2<br />

120-277<br />

IntelliVolt<br />

*Available Q3 2006.<br />

PS<br />

Optanium<br />

IOP-2S28-95-SC-SD*<br />

IOP-2S28-115-SC-SD*<br />

TBD<br />

TBD<br />

TBD<br />

TBD<br />

TBD<br />

TBD TBD B 173<br />

TBD<br />

CONTROLLABLE OPTANIUM<br />

1.18"<br />

8.90"<br />

9.5"<br />

1.7"<br />

Fig. B<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

2-3


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - AmbiStar <br />

<strong>Electronic</strong> <strong>Ballasts</strong> for 4-pin Compact Fluorescent<br />

STEP DIMMING<br />

<strong>Advance</strong>'s family of electronic ballasts specifically designed for popular fluorescent applications<br />

in homes and other non-commercial environments brings all of the energy-efficient benefits of<br />

fluorescent lighting to residential and hospitality applications. FCC Class B EMI compliant and<br />

available for 4-pin CFL lamps. <strong>Advance</strong>'s AmbiStar ballasts are compact and lightweight, provide<br />

quick starting light and save users significant energy costs relative to alternative lighting sources.<br />

AMBISTAR<br />

Features<br />

Dimmable from any incandescent or<br />

Mark 10 Powerline dimmer<br />

Meets Energy Star ballast requirements<br />

Rated for use in 65°C ambient<br />

Benefits<br />

Utilizes simplicity of incandescent dimming<br />

Enables usage where Energy Star fixtures are<br />

required<br />

Low ballast temperature rise allows for higher ambient<br />

applications<br />

Designed in the Size 1 housing<br />

Small housing provides for design flexibility<br />

2-4<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 18 - 42W Lamps<br />

T4<br />

NORMAL POWER FACTOR<br />

SOUND RATED A<br />

AmbiStar <strong>Electronic</strong> Dimming Ballast<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

Full Light Output<br />

CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4P, F18DBX/4P, CF18DD/E)<br />

CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W, F18TBX/4P, CF18DT/E)<br />

REB-2S18-M1-BS-DIM*<br />

1 120<br />

TBD<br />

TBD<br />

REB-2S18-M1-LS-DIM*<br />

PS AmbiStar<br />

0.80/0.15 TBD<br />

REB-2S18-M1-BS-DIM*<br />

2 120<br />

TBD<br />

TBD<br />

REB-2S18-M1-LS-DIM*<br />

CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E)<br />

CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W, F26TBX/4P, CF26DT/E)<br />

REB-2S26-M1-BS-DIM<br />

1 120<br />

TBD<br />

TBD<br />

REB-2S26-M1-LS-DIM<br />

PS AmbiStar<br />

0.80/0.15 TBD<br />

REB-2S26-M1-BS-DIM<br />

2 120<br />

53<br />

0.47<br />

REB-2S26-M1-LS-DIM<br />

50/10<br />

50/10<br />

Size 1<br />

Size 1<br />

138<br />

138<br />

CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W, F32TBX/4P, CF32DT/E)<br />

1 120 PS AmbiStar<br />

REB-2S26-M1-BS-DIM<br />

REB-2S26-M1-LS-DIM<br />

TBD 0.80/0.15 TBD TBD 50/10 Size 1 138<br />

CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W, F42TBX/4P, CF42DT/E)<br />

1 120 PS AmbiStar<br />

REB-2S26-M1-BS-DIM<br />

REB-2S26-M1-LS-DIM<br />

TBD 0.80/0.15 TBD TBD 50/10 Size 1 138<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

CONTROLLABLE AMBISTAR<br />

Some lamp manufacturers recommend burning in new lamps 100 hours at full light output before dimming. Consult lamp manufacturer.<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauges from AWG 16 - 20.<br />

Ballast dimmable from any incandescent or Mark 10 Powerline dimmer.<br />

*Available Q4 2006.<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

ONLY USE 4-PIN RAPID-START SOCKETS<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

2-5


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Mark 10 ® Powerline<br />

Mark 10 ® Powerline <strong>Electronic</strong> Dimming <strong>Ballasts</strong> for Linear Fluorescent, 4-Pin CFL,<br />

and T5/HO Lamps<br />

DIMMING<br />

<strong>Advance</strong>'s Mark 10 Powerline electronic dimming ballasts for Linear Fluorescent, 4-Pin CFL, and<br />

T5/HO Lamps are the full-range electronic dimming ballasts for fluorescent lighting systems.<br />

Flexible and easy to install because they require no additional wiring, Mark 10 Powerline ballasts<br />

combine the long life and energy efficiency of fluorescent technology with the controllability and<br />

full-range dimming capabilities of incandescent systems.<br />

MARK 10 Powerline<br />

Mark 10 Powerline ballasts are ideal in such applications as conference rooms, offices,<br />

auditoriums, educational facilities, hotels, restaurants, and department stores as well as other<br />

new construction or retrofit installations where dimming is desired.<br />

Features<br />

Benefits<br />

100% to 5% full-range continuous<br />

dimming (down to 1% in T5/HO models)<br />

Energy-efficient design<br />

Absence of additional control leads<br />

Programmed Start Ignition<br />

Lamp ignition at any light setting,<br />

including the 5% level (1% in T5/HO models)<br />

Increases system flexibility and enhances visual comfort<br />

Delivers up to 65% energy savings over standard<br />

Fixed Output T8 ballasts<br />

Enhances ease of installation (as no extra wiring is<br />

required) and is also highly flexible and compatible<br />

with a wide variety of controls by a broad range of<br />

control manufacturers<br />

Provides extended lamp life in frequent starting<br />

applications<br />

Eliminates the need to ramp up to 100% light output<br />

when starting<br />

2-6<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 18 - 70W Lamps<br />

T4<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Mark 10 Powerline <strong>Electronic</strong> Dimming Ballast<br />

No. of<br />

Lamps<br />

CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4P, F18DBX/4P, CF18DD/E)<br />

CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W, F18TBX/4P, CF18DT/E)<br />

120<br />

REZ-1Q18-M2-BS<br />

0.18<br />

REZ-1Q18-M2-LD<br />

1<br />

22/7<br />

277<br />

VEZ-1Q18-M2-BS<br />

Mark 10<br />

0.07<br />

VEZ-1Q18-M2-LD<br />

PS<br />

1.00/0.05 10<br />

120<br />

Powerline REZ-2Q18-M2-BS<br />

0.36<br />

REZ-2Q18-M2-LD<br />

2<br />

43/14<br />

277<br />

VEZ-2Q18-M2-BS<br />

0.16<br />

VEZ-2Q18-M2-LD<br />

CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E)<br />

CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W, F26TBX/4P, CF26DT/E)<br />

1<br />

2<br />

Input<br />

Volts<br />

120<br />

277<br />

120<br />

277<br />

Lamp<br />

Starting<br />

Method<br />

PS<br />

Note: ➀ Replacement/Retrofit Ballast Kits indicated by Bold Type with suffix -K<br />

are available to distributers. Refer to page__.<br />

For ballast dimensions<br />

see page 2-8<br />

Mark 10<br />

Powerline<br />

REZ-1T42-M2-BS<br />

REZ-1T42-M2-LD<br />

REZ-1T42-M2-LD-K ➀<br />

VEZ-1T42-M2-BS<br />

VEZ-1T42-M2-LD<br />

VEZ-1T42-M2-LD-K ➀<br />

REZ-2Q26-M2-BS<br />

REZ-2Q26-M2-LD<br />

REZ-2Q26-M2-LD-K ➀<br />

VEZ-2Q26-M2-BS<br />

VEZ-2Q26-M2-LD<br />

VEZ-2Q26-M2-LD-K ➀<br />

31/8<br />

58/16<br />

1.00/0.05 10<br />

CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W, F32TBX/4P, CF32DT/E)<br />

REZ-1T42-M2-BS<br />

120<br />

REZ-1T42-M2-LD<br />

REZ-1T42-M2-LD-K ➀<br />

1<br />

38/9<br />

VEZ-1T42-M2-BS<br />

277<br />

Mark 10<br />

PS<br />

VEZ-1T42-M2-LD<br />

1.00/0.05 10<br />

Powerline VEZ-1T42-M2-LD-K ➀<br />

120<br />

REZ-2T42-M3-BS<br />

REZ-2T42-M3-LD<br />

2<br />

76/20<br />

277<br />

VEZ-2T42-M3-BS<br />

VEZ-2T42-M3-LD<br />

CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W, F42TBX/4P, CF42DT/E)<br />

REZ-1T42-M2-BS<br />

120<br />

REZ-1T42-M2-LD<br />

REZ-1T42-M2-LD-K ➀<br />

1<br />

49/10<br />

VEZ-1T42-M2-BS<br />

277<br />

Mark 10<br />

PS<br />

VEZ-1T42-M2-LD<br />

1.00/0.05 10<br />

Powerline VEZ-1T42-M2-LD-K ➀<br />

REZ-2T42-M3-BS<br />

120<br />

2<br />

REZ-2T42-M3-LD<br />

98/20<br />

VEZ-2T42-M3-BS<br />

277<br />

VEZ-2T42-M3-LD<br />

CFTR57W/GX24q - 57W CFL Triple Tube Lamp (PL-T57W, F57QBX/4P, CF57DT/E)<br />

120<br />

REZ-2T42-M3-BS<br />

Mark 10 REZ-2T42-M3-LD<br />

1 PS<br />

66/18 1.00/0.05 10<br />

277<br />

Powerline VEZ-2T42-M3-BS<br />

VEZ-2T42-M3-LD<br />

CFTR70W/GX24q - 70W CFL Triple Tube Lamp (F70QBX/4P, CF70DT/E)<br />

120<br />

1 PS<br />

277<br />

Ballast<br />

Family<br />

Mark 10<br />

Powerline<br />

Catalog Number<br />

REZ-2T42-M3-BS<br />

REZ-2T42-M3-LD<br />

VEZ-2T42-M3-BS<br />

VEZ-2T42-M3-LD<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

80/18 1.00/0.05 10<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

0.26<br />

0.11<br />

0.48<br />

0.21<br />

0.32<br />

0.14<br />

0.64<br />

0.28<br />

0.41<br />

0.55<br />

0.24<br />

50/10 Size 2<br />

50/10 Size 2<br />

50/10<br />

0.18 50/10<br />

0.82<br />

0.36<br />

0.67<br />

0.29<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Size 2<br />

Size 3<br />

Size 2<br />

Size 3<br />

Wiring<br />

Dia.<br />

134<br />

132<br />

134<br />

132<br />

134<br />

132<br />

134<br />

132<br />

50/10 Size 3 134<br />

50/10 Size 3 134<br />

Some lamp manufacturers recommend burning in new lamps 100 hours at full light<br />

output before dimming. Consult lamp manufacturer.<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauges from AWG 16 - 20.<br />

ONLY USE 4-PIN RAPID-START SOCKETS<br />

Use compatible Mark 10 Powerline controls<br />

only as referenced on page 2-22 & 2-23<br />

CONTROLLABLE MARK 10<br />

POWERLINE<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

2-7


FT5<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 24 - 55W Lamps<br />

Mark 10 Powerline <strong>Electronic</strong> Dimming Ballast<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

FT24W/2G11 - 24/27WW Long Twin Tube Lamp (PL-L24W, F27BX/RS, FT24DL)<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

CONTROLLABLE<br />

MARK 10<br />

POWERLINE<br />

1<br />

2<br />

FT36W/2G11 - 36/39W Long Twin Tube Lamp (PL-L36W, F39BX/RS, FT36DL)<br />

120<br />

REZ-1TTS40-SC<br />

1<br />

38/9<br />

277<br />

Mark 10 VEZ-1TTS40-SC<br />

PS<br />

120<br />

Powerline REZ-2TTS40-SC<br />

2<br />

75/16<br />

277<br />

VEZ-2TTS40-SC<br />

1.00/0.05 10<br />

FT40W/2G11/RS - 40W Long Twin Tube Lamp (PL-L40W, F40BX, FT40DL/RS)<br />

120<br />

REZ-1TTS40-SC<br />

1<br />

41/10<br />

277<br />

Mark 10 VEZ-1TTS40-SC<br />

PS<br />

120<br />

Powerline REZ-2TTS40-SC<br />

2<br />

80/17<br />

277<br />

VEZ-2TTS40-SC<br />

1.00/0.05 10<br />

FT55W/2G11 - 55W Long Twin Tube Lamp (F55BX, FT55DL)<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

120<br />

277<br />

120<br />

277<br />

PS<br />

PS<br />

Mark 10<br />

Powerline<br />

Mark 10<br />

Powerline<br />

IEZ-124-D*<br />

IEZ-2S24-D<br />

REZ-154<br />

VEZ-154<br />

REZ-2S54<br />

VEZ-2S54<br />

TBD<br />

57/16<br />

59/13<br />

114/24<br />

1.00/0.05 10<br />

0.90/0.05 10<br />

TBD<br />

0.48-0.21<br />

0.32<br />

0.14<br />

0.64<br />

0.27<br />

0.32<br />

0.15<br />

0.68<br />

0.30<br />

0.50<br />

0.22<br />

0.96<br />

0.42<br />

50/10 D<br />

50/10 B<br />

50/10 B<br />

50/10 D<br />

134<br />

132<br />

134<br />

132<br />

134<br />

132<br />

134<br />

132<br />

Burn in new lamps 100 hours at full light before dimming.<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />

*Available Q4 2006.<br />

3.00"<br />

Size 2 Enclosure<br />

3.00"<br />

1.29"<br />

1.29" 2.00"<br />

4.20"<br />

4.60"<br />

4.20"<br />

4.60"<br />

1.18"<br />

8.90"<br />

9.5"<br />

-LD<br />

-BS<br />

1.7"<br />

Fig. B<br />

Fig. D<br />

Includes connectors with no leads<br />

3.00"<br />

Size 3 Enclosure<br />

1.29" 2.00"<br />

3.00"<br />

1.29"<br />

5.5"<br />

6.0"<br />

5.5"<br />

6.0" -BS<br />

Diag. 134 Diag. 132<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

Use compatible Mark 10 Powerline controls<br />

only as referenced on page 2-22 & 2-23<br />

-LD<br />

(Dual connector for input only)<br />

ONLY USE RAPID-START SOCKETS<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

2-8<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 24 - 55W Lamps<br />

T5/HO<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Mark 10 Powerline <strong>Electronic</strong> Dimming Ballast<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F24T5/HO (24W)<br />

1<br />

2<br />

F54T5/HO (54W)<br />

1<br />

2<br />

FC12T5/HO (55W)<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

120<br />

277<br />

120<br />

277<br />

120<br />

277<br />

120<br />

277<br />

PS<br />

PS<br />

PS<br />

Mark 10<br />

Powerline<br />

Mark 10<br />

Powerline<br />

Mark 10<br />

Powerline<br />

IEZ-124-D*<br />

IEZ-2S24-D<br />

REZ-154<br />

VEZ-154<br />

REZ-2S54<br />

VEZ-2S54<br />

REZ-154<br />

VEZ-154<br />

REZ-2S54<br />

VEZ-2S54<br />

TBD<br />

57/16<br />

63/13<br />

125/24<br />

59/13<br />

114/24<br />

1.00/0.05<br />

1.00/0.03<br />

0.90/0.03<br />

10<br />

10<br />

10<br />

TBD<br />

0.48-0.21<br />

0.53<br />

0.23<br />

1.05<br />

0.45<br />

0.50<br />

0.22<br />

0.96<br />

0.42<br />

50/10<br />

50/10<br />

50/10<br />

D<br />

D<br />

D<br />

152<br />

153<br />

152<br />

153<br />

152<br />

153<br />

CONTROLLABLE MARK 10<br />

POWERLINE<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />

*Available Q4 2006.<br />

ONLY USE RAPID-START SOCKETS<br />

Diag. 152<br />

Fig. D<br />

Includes connectors with no leads<br />

Diag. 153<br />

Use compatible Mark 10 Powerline controls<br />

only as referenced on page 2-22 & 2-23<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

2-9


T8<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 17 - 32W Lamps<br />

Mark 10 Powerline <strong>Electronic</strong> Dimming Ballast<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

CONTROLLABLE<br />

MARK 10<br />

POWERLINE<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

F17T8, FBO16T8 (17W)<br />

120<br />

1<br />

277<br />

120<br />

Mark 10<br />

2<br />

PS<br />

277<br />

Powerline<br />

120<br />

3<br />

277<br />

F25T8, FBO24T8 (25W)<br />

Ballast<br />

Family<br />

120<br />

1<br />

277<br />

120<br />

Mark 10<br />

2<br />

PS<br />

277<br />

Powerline<br />

120<br />

3<br />

277<br />

F32T8, FBO31T8, F32T8/U6 (32W)<br />

120<br />

1<br />

277<br />

120<br />

Mark 10<br />

2<br />

PS<br />

277<br />

Powerline<br />

120<br />

3<br />

277<br />

Catalog Number<br />

REZ-132-SC 0.20<br />

24/7<br />

VEZ-132-SC<br />

0.09<br />

152<br />

REZ-2S32-SC<br />

0.32<br />

38/13 1.05/0.05 10<br />

VEZ-2S32-SC<br />

0.14<br />

50/10 B 153<br />

REZ-3S32-SC<br />

0.47<br />

56/18<br />

VEZ-3S32-SC<br />

0.21<br />

155<br />

REZ-132-SC<br />

VEZ-132-SC<br />

REZ-2S32-SC<br />

VEZ-2S32-SC<br />

REZ-3S32-SC<br />

VEZ-3S32-SC<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

30/7<br />

55/13<br />

79/19<br />

Max/Min<br />

Ballast<br />

Factor<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

1.05/0.05 10<br />

0.26<br />

0.11<br />

0.46<br />

0.20<br />

0.66<br />

0.29<br />

50/10 B<br />

Wiring<br />

Dia.<br />

REZ-132-SC 0.29<br />

35/9<br />

VEZ-132-SC<br />

0.13<br />

152<br />

REZ-2S32-SC<br />

0.57<br />

68/15 1.00/0.05 10<br />

VEZ-2S32-SC<br />

0.25<br />

50/10 B 153<br />

REZ-3S32-SC<br />

0.86<br />

102/20<br />

VEZ-3S32-SC<br />

0.37<br />

155<br />

152<br />

153<br />

155<br />

ONLY USE RAPID-START SOCKETS<br />

Diag. 152<br />

1.18"<br />

8.90"<br />

9.5"<br />

1.7"<br />

Fig. B<br />

Diag. 153<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

Use compatible Mark 10 Powerline controls<br />

only as referenced on page 2-22 & 2-23<br />

Diag. 155<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

2-10<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Mark 7 ® 0-10 Volt<br />

0-10V <strong>Electronic</strong> Dimming <strong>Ballasts</strong> for Linear Fluorescent, 4-Pin CFL, and T5/HO Lamps<br />

<strong>Advance</strong>'s Mark 7 0-10V series of dimmable electronic ballasts for Linear Fluorescent, 4-Pin<br />

CFL, and T5/HO Lamps represent an affordable, flexible, and versatile dimming solution for a<br />

broad range of commercial, institutional, and retail applications. Ideal for energy management<br />

systems, Mark 7 0-10V ballasts offer full range continuous dimming and fully support sustainable<br />

(green) design.<br />

Mark 7 0-10V ballasts are ideal in such applications as conference rooms, auditoriums, educational<br />

facilities, hotels, restaurants, and department stores as well as other new construction or<br />

retrofit installations where dimming is desired.<br />

DIMMING MARK 70-10V<br />

Features<br />

100% to 5% full-range continuous<br />

dimming (down to 1% in T5/HO models)<br />

Energy-efficient design<br />

Direct operation from a 0-10V DC control<br />

signal<br />

Programmed Start ignition<br />

IntelliVolt ® multiple-voltage technology<br />

enabling operation at any input voltage<br />

from 120 to 277 volts, 50/60Hz<br />

Benefits<br />

Increases system flexibility and enhances visual comfort<br />

Delivers up to 65% energy savings over standard<br />

Fixed Output T8 ballasts<br />

Enables the need for fewer controls and allows for<br />

direct use of daylight harvesting and other low<br />

voltage controls<br />

Provides extended lamp life in frequent starting<br />

applications<br />

Enhances accuracy of ordering and reduces SKU<br />

requirements<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 2-11


T4<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 13 - 70W Lamps<br />

Mark 7 0-10V <strong>Electronic</strong> Dimming Ballast<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

CONTROLLABLE<br />

MARK 70-10V<br />

No. of<br />

Lamps<br />

CFQ13W/G24q - 13W CFL Quad Tube Lamp (PL-C13W/4P, F13DBX/4P, CF13DD/E)<br />

CFTR13W/GX24q - 13W CFL Triple Tube Lamp (F13TBX/4P, CF13DT/E)<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

PS<br />

Mark 7<br />

0-10V<br />

IZT-2S26-M5-BS<br />

IZT-2S26-M5-LD<br />

IZT-2S26-M5-BS<br />

IZT-2S26-M5-LD<br />

CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4P, F18DBX/4P, CF18DD/E)<br />

CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W, F18TBX/4P, CF18DT/E)<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

PS<br />

Mark 7<br />

0-10V<br />

IZT-2S26-M5-BS<br />

IZT-2S26-M5-LD<br />

IZT-2S26-M5-BS<br />

IZT-2S26-M5-LD<br />

CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E)<br />

CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W, F26TBX/4P, CF26DT/E)<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

PS<br />

Mark 7<br />

0-10V<br />

IZT-2S26-M5-BS<br />

IZT-2S26-M5-LD<br />

IZT-2S26-M5-BS<br />

IZT-2S26-M5-LD<br />

CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W, F32TBX/4P, CF32DT/E)<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

PS<br />

Mark 7<br />

0-10V<br />

IZT-2S26-M5-BS<br />

IZT-2S26-M5-LD<br />

IZT-2T42-M5-BS<br />

IZT-2T42-M5-LD<br />

CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W, F42TBX/4P, CF42DT/E)<br />

1<br />

2<br />

Input<br />

Volts<br />

120-277<br />

IntelliVolt<br />

Lamp<br />

Starting<br />

Method<br />

PS<br />

Ballast<br />

Family<br />

Mark 7<br />

0-10V<br />

Catalog Number<br />

IZT-2S26-M5-BS<br />

IZT-2S26-M5-LD<br />

IZT-2T42-M5-BS<br />

IZT-2T42-M5-LD<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

CFTR57W/GX24q - 57W CFL Triple Tube Lamp (PL-T57W, F57QBX/4P, CF57DT/E)<br />

120-277<br />

Mark 7 IZT-2T42-M5-BS<br />

1 PS<br />

65/16 1.00/0.03 10 0.55-0.24 50/10 Size 5 58A<br />

IntelliVolt<br />

0-10V IZT-2T42-M5-LD<br />

CFTR70W/GX24q - 70W CFL Triple Tube Lamp (F70QBX/4P, CF70DT/E)<br />

120-277<br />

Mark 7 IZT-2T42-M5-BS<br />

1 PS<br />

75/16 1.00/0.03 10 0.63-0.27 50/10 Size 5 58A<br />

IntelliVolt<br />

0-10V IZT-2T42-M5-LD<br />

18/6<br />

32/19<br />

20/7<br />

41/11<br />

28/8<br />

49/13<br />

34/9<br />

75/19<br />

46/9<br />

98/18<br />

Max/Min<br />

Ballast<br />

Factor<br />

THD %<br />

1.00/0.03 10<br />

1.00/0.03 10<br />

1.00/0.03 10<br />

1.00/0.03 10<br />

1.00/0.03 10<br />

Full Light Output<br />

Line<br />

Current<br />

(Amps)<br />

0.14-0.07<br />

0.26-0.12<br />

0.15-0.08<br />

0.32-0.15<br />

0.22-0.10<br />

0.41-0.18<br />

0.28-0.13<br />

0.63-0.21<br />

0.38-0.17<br />

0.82-0.36<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

50/10 Size 5<br />

50/10 Size 5<br />

50/10 Size 5<br />

50/10 Size 5<br />

50/10 Size 5<br />

Wiring<br />

Dia.<br />

58A<br />

59A<br />

58A<br />

59A<br />

58A<br />

59A<br />

58A<br />

59A<br />

58A<br />

59A<br />

Some lamp manufacturers recommend burning in new lamps 100 hours at<br />

full light output before dimming. Consult lamp manufacturer.<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauges from AWG 16 - 20.<br />

BLACK<br />

LINE<br />

WHITE<br />

CLASS 1 OR 2 VIOLET (+)<br />

CIRCUIT { GREY (-)<br />

10V, 0.5 mA<br />

BALLAST<br />

RED<br />

BLUE<br />

BLACK<br />

LINE<br />

WHITE<br />

CLASS 1 OR 2 VIOLET (+)<br />

CIRCUIT { GREY (-)<br />

10V, 0.5 mA<br />

BALLAST<br />

RED<br />

YELLOW<br />

BLUE<br />

ONLY USE 4-PIN RAPID-START SOCKETS<br />

Mark 7 0-10V Control Wiring (Grey and Violet)<br />

Wire Size Maximum Length (Ft.)<br />

AWG-16 800<br />

AWG-18 500<br />

AWG-20 320<br />

Diag. 58A<br />

For ballast dimensions<br />

see page 2-13<br />

Diag. 59A<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

2-12<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 36 - 80W Lamps<br />

FT5<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Mark 7 0-10V <strong>Electronic</strong> Dimming Ballast<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

FT36W/2G11 - 36/39W Long Twin Tube Lamp (PL-L36W, F39BX/RS, FT36DL)<br />

120-277<br />

Mark 7<br />

2 PS<br />

IZT-2TTS40-SC 75/16 1.00/0.03 10 0.64-0.27 50/10 B 59A<br />

IntelliVolt<br />

0-10V<br />

FT40W/2G11/RS - 40W Long Twin Tube Lamp (PL-L40W, F40BX, FT40DL/RS)<br />

120<br />

RZT-1TTS40<br />

0.32<br />

1<br />

38/11<br />

58A<br />

277<br />

VZT-1TTS40<br />

0.14<br />

A<br />

120<br />

Mark 7 RZT-2TTS40<br />

0.64<br />

PS<br />

1.00/0.05 10<br />

50/10<br />

277<br />

0-10V VZT-2TTS40<br />

0.28<br />

2<br />

76/16<br />

59A<br />

120-277<br />

IZT-2TTS40-SC<br />

0.64-0.28<br />

B<br />

IntelliVolt<br />

FT55W/2G11 - 55W Long Twin Tube Lamp (F55BX, FT55DL)<br />

120<br />

RZT-154<br />

1<br />

59/13<br />

277<br />

Mark 7 VZT-154<br />

PS<br />

120<br />

0-10V RZT-2S54<br />

2<br />

114/24<br />

277<br />

VZT-2S54<br />

FT80W/2G11 - 80W Long Twin Tube Lamp (PL-L80W, FT80)<br />

Mark 7<br />

2 277 PS<br />

VZT-180<br />

0-10V<br />

Max/Min<br />

Ballast<br />

Factor<br />

THD %<br />

0.90/0.30 10<br />

Full Light Output<br />

Line<br />

Current<br />

(Amps)<br />

0.50<br />

0.22<br />

0.96<br />

0.42<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

50/10 D<br />

Wiring<br />

Dia.<br />

58A<br />

59A<br />

94/16 1.00/0.03 10 0.34 50/10 D 58A<br />

CONTROLLABLE MARK 70-10V<br />

Burn in new lamps 100 hours at full light output before dimming.<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />

ONLY USE RAPID-START SOCKETS<br />

BLACK<br />

LINE<br />

WHITE<br />

CLASS 1 OR 2 VIOLET (+)<br />

CIRCUIT { GREY (-)<br />

10V, 0.5 mA<br />

BALLAST<br />

RED<br />

BLUE<br />

BLACK<br />

LINE<br />

WHITE<br />

CLASS 1 OR 2 VIOLET (+)<br />

CIRCUIT { GREY (-)<br />

10V, 0.5 mA<br />

BALLAST<br />

RED<br />

YELLOW<br />

BLUE<br />

Fig. A<br />

Diag. 58A<br />

Diag. 59A<br />

Fig. D<br />

Includes connectors with no leads<br />

Size 5<br />

3.00" (76.4)<br />

1.18" (30.0)<br />

3.00" (76.4) 2.00" (50.8)<br />

1.18" (30.0)<br />

M5<br />

4.20" (106.7)<br />

4.55" (116.6)<br />

-BS<br />

1.18"<br />

1.7"<br />

8.90"<br />

9.5"<br />

Fig. B<br />

Use compatible low voltage controls<br />

only as referenced on page 2-22 & 2-23<br />

4.20" (106.7)<br />

4.55" (116.6)<br />

-LD<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

2-13


T5/HO<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 54 - 80W Lamps<br />

Mark 7 0-10V <strong>Electronic</strong> Dimming Ballast<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F54T5/HO (54W)<br />

CONTROLLABLE<br />

1<br />

2<br />

120<br />

277<br />

120<br />

277<br />

F80T5/HO (80W)<br />

PS<br />

1 277 PS<br />

Mark 7<br />

0-10V<br />

Mark 7<br />

0-10V<br />

RZT-154<br />

VZT-154<br />

RZT-2S54<br />

VZT-2S54<br />

VZT-180<br />

63/13<br />

125/24<br />

1.00/0.03<br />

94/18 1.00/0.03<br />

10<br />

10<br />

0.53<br />

0.23<br />

1.05<br />

0.45<br />

0.34<br />

50/10<br />

50/10<br />

D<br />

D<br />

55A<br />

56A<br />

55A<br />

MARK 70-10V<br />

FC12T5/HO (55W)<br />

120<br />

1<br />

277<br />

PS<br />

120<br />

2<br />

277<br />

Mark 7<br />

0-10V<br />

RZT-154<br />

VZT-154<br />

RZT-2S54<br />

VZT-2S54<br />

59/13<br />

114/24<br />

0.90/0.03<br />

10<br />

0.50<br />

0.22<br />

0.96<br />

0.42<br />

50/10<br />

D<br />

55A<br />

56A<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />

ONLY USE RAPID-START SOCKETS<br />

Mark 7 0-10V Control Wiring (Grey and Violet)<br />

Wire Size Maximum Length (Ft.)<br />

AWG-16 800<br />

AWG-18 500<br />

AWG-20 320<br />

Fig. D<br />

Includes connectors with no leads<br />

Use compatible low voltage controls<br />

only as referenced on page 2-22 & 2-23<br />

LINE<br />

CLASS 1 OR 2<br />

CIRCUIT<br />

10V, 0.5 mA<br />

BLACK<br />

WHITE<br />

VIOLET (+)<br />

{ GREY (-)<br />

BALLAST<br />

RED<br />

BLUE<br />

LINE<br />

CLASS 1 OR 2<br />

CIRCUIT<br />

10V, 0.5 mA<br />

BLACK<br />

WHITE<br />

VIOLET (+)<br />

{ GREY (-)<br />

BALLAST<br />

RED<br />

BLUE<br />

YELLOW<br />

LAMP<br />

LAMP<br />

LAMP<br />

Diag. 55A<br />

Diag. 56A<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

2-14<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 17 - 25W Lamps<br />

T8<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Mark 7 0-10V <strong>Electronic</strong> Dimming Ballast<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F17T8, FBO16T8 (17W)<br />

1 IZT-132-SC<br />

20/7 0.16-0.07 55A<br />

2<br />

3<br />

120-277<br />

IntelliVolt<br />

PS<br />

F25T8, FBO24T8 (25W)<br />

1<br />

2<br />

3<br />

120-277<br />

IntelliVolt<br />

PS<br />

Mark 7<br />

0-10V<br />

Mark 7<br />

0-10V<br />

IZT-2S32-SC<br />

IZT-3S32-SC<br />

IZT-132-SC<br />

IZT-2S32-SC<br />

IZT-3S32-SC<br />

36/11<br />

56/18<br />

28/8<br />

52/12<br />

79/19<br />

1.00/0.03 10 0.30-0.13 50/10 B<br />

1.00/0.03<br />

0.46-0.20<br />

0.24-0.11<br />

0.43-0.19<br />

10 50/10<br />

0.65-0.28<br />

B<br />

56A<br />

57A<br />

55A<br />

56A<br />

57A<br />

CONTROLLABLE MARK 70-10V<br />

4<br />

IZT-4S32<br />

96/22<br />

0.88/0.03<br />

0.77-0.35<br />

D<br />

16A<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />

Fig. A<br />

1.18"<br />

8.90"<br />

9.5"<br />

1.7"<br />

Fig. B<br />

ONLY USE RAPID-START SOCKETS<br />

Mark 7 0-10V Control Wiring (Grey and Violet)<br />

Wire Size Maximum Length (Ft.)<br />

AWG-16 800<br />

Fig. G<br />

AWG-18 500<br />

AWG-20 320<br />

AWG-22 200<br />

AWG-24 120<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

Fig. D<br />

Includes connectors with no leads<br />

Use compatible low voltage controls<br />

only as referenced on page 2-22 & 2-23<br />

For wiring diagrams see page 2-13<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

2-15


T8<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 32W Lamps<br />

Mark 7 0-10V <strong>Electronic</strong> Dimming Ballast<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

F32T8, FBO31T8, F32T8/U6 (32W)<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

1<br />

IZT-132-SC<br />

35/8 0.30-0.13<br />

55A<br />

CONTROLLABLE<br />

2<br />

3<br />

120-277<br />

IntelliVolt<br />

PS<br />

Mark 7<br />

0-10V<br />

IZT-2S32-SC<br />

IZT-3S32-SC<br />

70/14<br />

102/20<br />

1.00/0.03<br />

0.57-0.24<br />

10 0.86-0.37 50/10<br />

B<br />

56A<br />

57A<br />

MARK 70-10V<br />

4<br />

277<br />

120-277<br />

IntelliVolt<br />

VZT-4S32-HL<br />

IZT-4S32<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />

149/27<br />

116/25<br />

1.18/0.05<br />

0.88/0.03<br />

0.54<br />

0.98-0.42<br />

G<br />

D<br />

16A<br />

16A<br />

LINE<br />

CLASS 1 OR 2<br />

CIRCUIT<br />

10V, 0.5 mA<br />

BLACK<br />

WHITE<br />

VIOLET (+)<br />

{ GREY (-)<br />

BALLAST<br />

RED<br />

BLUE<br />

LINE<br />

CLASS 1 OR 2<br />

CIRCUIT<br />

10V, 0.5 mA<br />

BLACK<br />

WHITE<br />

VIOLET (+)<br />

{ GREY (-)<br />

BALLAST<br />

RED<br />

BLUE<br />

YELLOW<br />

BLACK<br />

LINE<br />

WHITE<br />

CLASS 1 OR 2 VIOLET (+)<br />

CIRCUIT { GREY (-)<br />

10V, 0.5 mA<br />

BALLAST<br />

LAMP<br />

RED<br />

BLUE/WHITE<br />

BLUE<br />

YELLOW<br />

LAMP<br />

LAMP<br />

LAMP<br />

LAMP<br />

LAMP<br />

Diag. 55A<br />

Diag. 56A<br />

Diag. 57A<br />

or<br />

RED<br />

YELLOW<br />

LAMP<br />

BALLAST<br />

BLUE/WHITE<br />

LAMP<br />

LAMP<br />

Diag. 16A<br />

LAMP<br />

ONLY USE RAPID-START SOCKETS<br />

Mark 7 0-10V Control Wiring (Grey and Violet)<br />

Wire Size Maximum Length (Ft.)<br />

AWG-16 800<br />

AWG-18 500<br />

AWG-20 320<br />

AWG-22 200<br />

AWG-24 120<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

For ballast dimensions<br />

see page 2-13<br />

Use compatible low voltage controls<br />

only as referenced on page 2-22 & 2-23<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

2-16<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - ROVR<br />

Digital Addressable <strong>Ballasts</strong> for Linear Fluorescent, 4-Pin CFL, and T5/HO Lamps<br />

<strong>Advance</strong>'s ROVR series of digital addressable controllable fluorescent lamp ballasts are fully<br />

compatible with the DALI (Digital Addressable Lighting Interface) protocol, enabling two-way<br />

communications with individual lighting fixtures. ROVR ballasts offer an unprecedented degree<br />

of design flexibility, allowing users to set up any fluorescent lighting configuration they desire<br />

with numerous distinct dimming performance settings. Offering the ability to track and evaluate<br />

lighting systems as well as easily accommodate any moves or changes in the lighting configuration,<br />

ROVR ballasts fully support sustainable (green) design and are compatible with controls<br />

offered by numerous manufacturers.<br />

ROVR is ideal in applications such as conference rooms, educational facilities, auditoriums,<br />

hotels, and restaurants.<br />

DIMMING ROVR<br />

Features<br />

Full-range continuous dimming from 100%<br />

to 3% (down to 1% in T5/HO models)<br />

Operation directly from the DALI control<br />

signal<br />

Programmed Start ignition<br />

IntelliVolt® multiple-voltage technology<br />

enabling operation at any input voltage<br />

from 120 to 277 volts, 50/60Hz<br />

Color-coded, poke-in connectors on all<br />

CFL, T5/HO, and 4-Lamp T8 models<br />

Benefits<br />

Increases system flexibility and enhances visual comfort<br />

Supports sustainable design principles such as<br />

daylight harvesting<br />

Provides extended lamp life in frequent starting<br />

applications<br />

Enhances accuracy of ordering and reduces SKU<br />

requirements<br />

Enhances wiring accuracy and ease of<br />

assembly/installation<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 2-17


T4<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 13 - 70W Lamps<br />

ROVR Digital Addressable Ballast<br />

NORMAL POWER FACTOR<br />

SOUND RATED A<br />

CONTROLLABLE<br />

ROVR<br />

No. of<br />

Lamps<br />

CFQ13W/G24q - 13W CFL Quad Tube Lamp (PL-C13W/4P, F13DBX/4P, CF13DD/E)<br />

CFTR13W/GX24q - 13W CFL Triple Tube Lamp (F13TBX/4P, CF13DT/E)<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

PS<br />

ROVR<br />

IDL-2S26-M5-BS<br />

IDL-2S26-M5-LD<br />

IDL-2S26-M5-BS<br />

IDL-2S26-M5-LD<br />

CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4P, F18DBX/4P, CF18DD/E)<br />

CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W, F18TBX/4P, CF18DT/E)<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

PS<br />

ROVR<br />

IDL-2S26-M5-BS<br />

IDL-2S26-M5-LD<br />

IDL-2S26-M5-BS<br />

IDL-2S26-M5-LD<br />

CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E)<br />

CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W, F26TBX/4P, CF26DT/E)<br />

1<br />

2<br />

PS<br />

ROVR<br />

CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W, F32TBX/4P, CF32DT/E)<br />

1<br />

2<br />

CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W, F42TBX/4P, CF42DT/E)<br />

1<br />

2<br />

Input<br />

Volts<br />

120-277<br />

IntelliVolt<br />

120-277<br />

IntelliVolt<br />

120-277<br />

IntelliVolt<br />

Lamp<br />

Starting<br />

Method<br />

PS<br />

PS<br />

Ballast<br />

Family<br />

ROVR<br />

ROVR<br />

Catalog Number<br />

IDL-2S26-M5-BS<br />

IDL-2S26-M5-LD<br />

IDL-2S26-M5-BS<br />

IDL-2S26-M5-LD<br />

IDL-2S26-M5-BS<br />

IDL-2S26-M5-LD<br />

IDL-2T42-M5-BS<br />

IDL-2T42-M5-LD<br />

IDL-2S26-M5-BS<br />

IDL-2S26-M5-LD<br />

IDL-2T42-M5-BS<br />

IDL-2T42-M5-LD<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

CFTR57W/GX24q - 57W CFL Triple Tube Lamp (PL-T57W, F57QBX/4P, CF57DT/E)<br />

120-277<br />

IDL-2T42-M5-BS<br />

1 PS ROVR 65/16 1.00/0.03 10 0.55-0.24 50/10 Size 5 165<br />

IntelliVolt<br />

IDL-2T42-M5-LD<br />

CFTR70W/GX24q - 70W CFL Triple Tube Lamp (F70QBX/4P, CF70DT/E)<br />

120-277<br />

IDL-2T42-M5-BS<br />

1 PS ROVR 75/16 1.00/0.03 10 0.63-0.27 50/10 Size 5 165<br />

IntelliVolt<br />

IDL-2T42-M5-LD<br />

18/6<br />

32/19<br />

20/7<br />

41/11<br />

28/8<br />

49/13<br />

34/9<br />

75/19<br />

46/9<br />

98/18<br />

Max/Min<br />

Ballast<br />

Factor<br />

1.00/0.03 10<br />

1.00/0.03 10<br />

1.00/0.03 10<br />

1.00/0.03 10<br />

1.00/0.03 10<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

0.14-0.07<br />

0.26-0.12<br />

0.15-0.08<br />

0.32-0.15<br />

0.22-0.10<br />

0.41-0.18<br />

0.28-0.13<br />

0.63-0.21<br />

0.38-0.17<br />

0.82-0.36<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

50/10 Size 5<br />

50/10 Size 5<br />

50/10 Size 5<br />

50/10 Size 5<br />

50/10 Size 5<br />

Wiring<br />

Dia.<br />

58B<br />

59B<br />

58B<br />

59B<br />

58B<br />

59B<br />

58B<br />

59B<br />

58B<br />

59B<br />

Burn in new lamps 100 hours at full light output before dimming.<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauges from AWG 16 - 20.<br />

ONLY USE 4-PIN RAPID-START SOCKETS<br />

For wiring diagrams<br />

see page 2-19<br />

Use compatible ROVR controls only<br />

as referenced on page 2-22 & 2-23<br />

For ballast dimensions<br />

see page 2-19<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

2-18<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 24W Lamps<br />

FT5<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ROVR Digital Addressable Ballast<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

THD %<br />

FT24W/2G11 - 24/27WW Long Twin Tube Lamp (PL-L24W, F27BX/RS, FT24DL)<br />

Full Light Output<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

PS<br />

ROVR<br />

IDA-154*<br />

IDA-2S54<br />

Burn in new lamps 100 hours at full light output before dimming.<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />

*Available Q4 2006.<br />

ONLY USE RAPID-START SOCKETS<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

59/13<br />

114/24<br />

0.50-0.22<br />

0.90/0.03 10<br />

50/10 D 165<br />

0.96-0.42<br />

3.00" (76.4) 2.00" (50.8)<br />

Size 5<br />

1.18" (30.0)<br />

M5<br />

4.20" (106.7)<br />

3.00" (76.4)<br />

4.55" (116.6)<br />

CONTROLLABLE ROVR<br />

1.18" (30.0)<br />

-BS<br />

4.20" (106.7)<br />

4.55" (116.6)<br />

-LD<br />

Fig. D<br />

Includes connectors with no leads<br />

DALI<br />

Class 1 or<br />

Class 2 Circuit<br />

{<br />

GREEN<br />

WHITE<br />

BLACK<br />

PURPLE<br />

PURPLE<br />

WIRING: (2) QUAD/TRIPLE LAMPS<br />

BLUE<br />

BALLAST YELLOW<br />

RED<br />

(1) QUAD/TRIPLE LAMP<br />

BLUE<br />

RED<br />

Green Terminal Must Be Grounded<br />

Diag. 165<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

Use compatible ROVR controls only<br />

as referenced on page 2-22 & 2-23<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

2-19


T5/HO<br />

HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 54 - 55W Lamps<br />

ROVR Digital Addressable Ballast<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

F54T5/HO (54W)<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

CONTROLLABLE<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

FC12T5/HO (55W)<br />

PS<br />

ROVR<br />

IDA-154*<br />

IDA-2S54<br />

63/13<br />

125/24<br />

1.00/0.03<br />

10<br />

0.53-0.23<br />

1.05-0.45<br />

50/10<br />

D<br />

55B<br />

56B<br />

1<br />

2<br />

120-277<br />

IntelliVolt<br />

PS<br />

ROVR<br />

IDA-154*<br />

IDA-2S54<br />

59/13<br />

114/24<br />

0.90/0.03<br />

10<br />

0.50-0.22<br />

0.96-0.42<br />

50/10<br />

D<br />

55B<br />

56B<br />

ROVR<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />

*Available Q4 2006.<br />

ONLY USE RAPID-START SOCKETS<br />

Fig. D<br />

Includes connectors with no leads<br />

LINE<br />

DALI<br />

Class 1 or<br />

Class 2 Circuit<br />

{<br />

BLACK<br />

WHITE<br />

PURPLE<br />

PURPLE<br />

BALLAST<br />

RED<br />

BLUE<br />

LINE<br />

Class 1 or Class 2<br />

Circuit {<br />

BLACK<br />

WHITE<br />

PURPLE<br />

PURPLE<br />

BALLAST<br />

LAMP<br />

RED<br />

BLUE/WHITE<br />

BLUE<br />

YELLOW<br />

LAMP<br />

LAMP<br />

LAMP<br />

Diag. 55B<br />

Diag. 56B<br />

Diag. 57B<br />

DALI<br />

Class 1 or<br />

Class 2<br />

Circuit<br />

{<br />

PURPLE<br />

PURPLE<br />

GREEN<br />

BLACK<br />

BALLAST<br />

RED<br />

YELLOW<br />

BLUE/WHITE<br />

LAMP<br />

LAMP<br />

LAMP<br />

LINE<br />

WHITE<br />

BROWN<br />

BLUE<br />

LAMP<br />

Diag. 167<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

Use compatible ROVR controls only<br />

as referenced on page 2-22 & 2-23<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

2-20<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

For 17 - 32W Lamps<br />

T8<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ROVR Digital Addressable Ballast<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max/Min<br />

Ballast<br />

Factor<br />

Full Light Output<br />

THD %<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F17T8, FBO16T8 (17W)<br />

1<br />

2<br />

F25T8, FBO24T8 (25W)<br />

1<br />

2<br />

3<br />

120-277<br />

IntelliVolt<br />

120-277<br />

IntelliVolt<br />

PS<br />

PS<br />

ROVR<br />

ROVR<br />

IDA-132-SC*<br />

IDA-2S32-SC*<br />

IDA-132-SC*<br />

IDA-2S32-SC*<br />

IDA-3S32-G<br />

20/7<br />

36/11<br />

28/8<br />

52/12<br />

79/19<br />

1.00/0.03<br />

1.00/0.03<br />

10<br />

10<br />

0.16-0.07<br />

0.30-0.13<br />

0.24-0.11<br />

0.43-0.19<br />

0.65-0.28<br />

50/10<br />

50/10<br />

B<br />

B<br />

G<br />

55B<br />

56B<br />

55B<br />

56B<br />

57B<br />

CONTROLLABLE ROVR<br />

4<br />

IDA-4S32<br />

96/22<br />

0.88/0.03<br />

0.77-0.35<br />

D<br />

167<br />

F32T8, FBO31T8, F32T8/U6 (32W)<br />

1<br />

IDA-132-SC*<br />

35/8<br />

0.30-0.13<br />

55B<br />

B<br />

2<br />

3<br />

120-277<br />

IntelliVolt<br />

PS<br />

ROVR<br />

IDA-2S32-SC*<br />

IDA-3S32-G<br />

70/14<br />

102/20<br />

1.00/0.03<br />

0.57-0.24<br />

10 50/10<br />

0.86-0.37<br />

G<br />

56B<br />

57B<br />

4<br />

IDA-4S32<br />

116/25<br />

0.88/0.03<br />

0.98-0.42<br />

D<br />

167<br />

<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />

*Available Q4 2006.<br />

ONLY USE RAPID-START SOCKETS<br />

Fig. G<br />

1.18"<br />

8.90"<br />

9.5"<br />

1.7"<br />

Fig. B<br />

Refer to page 1-15 for information on remote/tandem<br />

wiring and lead length extension<br />

Fig. D<br />

Includes connectors with no leads<br />

For wiring diagrams<br />

see page 2-20<br />

Use compatible ROVR controls only<br />

as referenced on page 2-22 & 2-23<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

2-21


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Control Manufacturers for <strong>Advance</strong> ® Mark 7 0-10V <strong>Electronic</strong> Dimming<br />

<strong>Ballasts</strong> and Mark 10 Powerline <strong>Electronic</strong> Dimming <strong>Ballasts</strong><br />

ROVR Digital Addressable <strong>Ballasts</strong><br />

MANUFACTURER PHONE MARK 7 0-10V 4-Wire MARK 10 Powerline 2-Wire Line Voltage ROVR<br />

Alerton Technologies Inc. 425-869-8400 TX16160 N/A<br />

ALM Systems Inc. 847-860-0959 SS-120 OR SS-277 ABIUF Dimming Module<br />

AMX Corporation 800-222-0193 Radia (RDM-HDC) & RDM-DC RDD & RDM Series<br />

Series<br />

Automated Logic Corp. 770-429-3000 S Series & M Series S Series and M Series<br />

CONTROLLABLE<br />

COMPATIBLE<br />

CONTROL<br />

Avab America 415-505-5515 PWR Series PWR Series<br />

Blackbird 800-421-3562 2BMO-FLST-AB-IR BBMO-MX-AB-IR<br />

Colortran, Inc. 503-682-1941 Digital Ballast Controller ENR, I Series, I Series E, and<br />

I Series Quad<br />

Crestron <strong>Electronic</strong>s 201-767-3400 CresLite Lighting System CresLite Lighting System<br />

Cutler-Hammer 803-481-6870 POW-R-Command System N/A<br />

Digital Lighting Systems 305-264-8391 Protocol Protocol<br />

Douglas Lighting Controls 604-873-2797 WPC-5700, WPN-5721, MC6000, MC6000, Dilor ALC3<br />

Dilor ALC3, Lightpoint WBC-2512<br />

Echo Controls 866-ECHODIM Echo-Dim<br />

<strong>Electronic</strong> Theatre Controls 608-831-4116 SENSOR or UNISON SENSOR or UNISON<br />

<strong>Electronic</strong>s Diversified, Inc. 503-645-5533 Prolite Dimming System, Versa- Prolite Dimming System, Versa-Pak<br />

Pak System, Mark 10 System Rack System, Mark 10 System Rack<br />

Entertainment Technologies 800-223-9477 Tap Glide, IPS, Capio Plus, Oasis Intelli Set Plus, Tap Glide, U-Set, IPS,<br />

Honeywell, Inc. 800-345-6770 EL7315A1019 or EL7315A1009 N/A<br />

Capio Plus<br />

Hubbell Building Automation 888-698-3242 DLC-7, OMNI, Light Owl, OMNI, Light Owl, Light Hawk, LP-2<br />

Light Hawk, LP-2<br />

Hunt Dimming 970-484-9048 PS, FD and SSD Simplicity Series PS, SC, FD and SSD Simplicity Series PS Series<br />

Intelligent Lighting Controls 800-922-8004 Light Master<br />

Johnson Controls 414-274-4000 Application Specific N/A<br />

Leax Controls 970-927-4845 Consult Factory Consult Factory<br />

Lehigh <strong>Electric</strong> Products Co. 610-395-3386 Sentry, Solitaire, DX2, Solitaire, DX2,<br />

Sunburst, ALX and DX with<br />

Sunburst, ALX and DX with<br />

DCFL Interface<br />

ACFL Interface<br />

Leviton Lighting Control Div. 800-824-3005 Centura, Wallbox: IllumaTech, Wallbox Dimmers: Monet, Renoir, Mural, CD100<br />

PE300-D (Slave Pack). TouchPoint, IllumaTech, SureSlide. CD250<br />

Occupancy Sensors: Multi-Tech, Occupancy Sensors: Multi-Tech, Wide<br />

Wide View, High Bay, Ultrasonic. View, High Bay, Ultrasonic, PIR.<br />

Systems: a-2000, MDS, D3200 Systems: a-2000, I series e, MDS,<br />

Power Master Station, Dimensions D3200<br />

The listed manufacturers have indicated that they manufacture products that properly control the <strong>Advance</strong> Mark 7 0-10V electronic dimming ballasts,<br />

<strong>Advance</strong> Mark 10 Powerline electronic dimming ballasts, or ROVR digital addressable ballasts. <strong>Advance</strong> Transformer provides this list as a service to our<br />

customers and control manufacturers. <strong>Advance</strong> does not support or recommend one manufacturer over another. Please refer to each manufacturer's catalog<br />

for a complete product description and performance specifications.<br />

2-22<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Control Manufacturers for <strong>Advance</strong> ® Mark 7 0-10V <strong>Electronic</strong> Dimming<br />

<strong>Ballasts</strong> and Mark 10 Powerline <strong>Electronic</strong> Dimming <strong>Ballasts</strong><br />

ROVR Digital Addressable <strong>Ballasts</strong><br />

MANUFACTURER PHONE MARK 7 0-10V 4-Wire MARK 10 Powerline 2-Wire Line Voltage ROVR<br />

Lighting Control and Design 323-226-0000 GR4000 GR4000<br />

Lightolier Controls 800-526-2731 Sunrise Preset, Momentum Preset, MultiSet Pro, Sunrise Preset,<br />

Vega Slider, Lytemode module Momentum Preset, Onset, Vega Slider,<br />

Lytemode module<br />

Lithonia Controls 770-987-4200 SLD, Equinox, Digital Equinox, DSD, SLD, Synergy, Sequel, Litronic<br />

Synergy, Sequel, Litronic<br />

Lutron 800-523-9466 See www.lutron.com/advance See www.lutron.com/advance<br />

Marlin Controls 800-788-5750 EFD, Stellar Starbright Dimming System Stellar<br />

NexLight 218-828-3700 WR, WRT, WTV Series Switches WR, WRT, WTV Series Switches and<br />

and Components, LS III<br />

Components, LS III<br />

Novar Controls 330-670-1010 FDI (Fluorescent Dimming Interface) N/A<br />

Novitas 310-568-9600 Wide array of ceiling sensors, wall N/A<br />

sensors, and photocells<br />

Payne Sparkman Mfg., Inc. 812-944-4893 LTRD/4W Series LTRD/2W Series<br />

CONTROLLABLE COMPATIBLE<br />

CONTROL<br />

PDM <strong>Electric</strong>al Products 514-342-6581 WPC-5700, WPN-5721, MC6000, MC6000, Dilor ALC3<br />

Dilor ALC3, Lightpoint WBC-2512<br />

PLC Multipoint 425-353-7552 EDSAB and RCD Dial EDSPR<br />

Sensor Switch, Inc. 800-727-7483 CM-ALC, CM-9, CM-PDT, CM-PC, N/A<br />

WV-16, WV-PDT<br />

Starfield Controls 303-427-1661 TaskRite TaskRite TaskRite<br />

DALInet<br />

Sterner Controls 320-543-3595 BPM-ELVFL-0-10 or ARA series BPM-EHVFL-2W or ARA series<br />

Strand Lighting 714-230-8200 <strong>Electronic</strong> Fluorescent Ballast DE90 & CD80S Dimming Systems<br />

Controller (120/277V)<br />

Touch-Plate Lighting 219-426-1565 CPD-8000D & MCP Series MCD-4000 & CPD-4000<br />

TRIATEK Lighting Inc. 800-241-9173 Digi-Touch NA<br />

Vantage Lighting Control 801-229-2800 SD4008-120, SD9008-277, LVOS SD4008-120, SD9008-277, Scenepoint,<br />

Radiolink Scenepoint, Powerstation 110V,<br />

Powerstation 277V<br />

Vara-Light/Dimatronics/HUB 815-455-4400 PFC-Analog and PGS-M-Digital DCM with FL-60 (digital) or<br />

M36 (analog)<br />

Watt Stopper, Inc. 408-988-5331 LS, IRT, W, WT, CI, CX, DT, IRC, WD 170, WD 180, WD270, and WD 280 ezDALI<br />

LIGHTSAVER<br />

The listed manufacturers have indicated that they manufacture products that properly control the <strong>Advance</strong> Mark 7 0-10V electronic dimming ballasts,<br />

<strong>Advance</strong> Mark 10 Powerline electronic dimming ballasts, or ROVR digital addressable ballasts. <strong>Advance</strong> Transformer provides this list as a service to our<br />

customers and control manufacturers. <strong>Advance</strong> does not support or recommend one manufacturer over another. Please refer to each manufacturer's catalog<br />

for a complete product description and performance specifications.<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 2-23


ELECTROMAGNETIC BALLASTS<br />

ELECTROMAGNETIC<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


ELECTROMAGNETIC BALLASTS<br />

Case - rugged steel ballast case Thermal Protector - exclusive ADVAN-guard ®<br />

automatic reclosing protective device affords<br />

Class P thermal protection on all ADVANCE fluorescent<br />

lamp ballasts ordered with”TP” suffix.<br />

Compound - special thermal-pliable compound<br />

containing a high percentage of silica<br />

ensures rapid heat conductivity. Dampens<br />

vibration and ballast hum. Careful filling<br />

excludes moisture, increases insulation<br />

resistance.<br />

Dry Capacitor - is used for power factor correction<br />

and phase displacement, capacitors<br />

(used only on high power factor ballast) are<br />

of highest quality. Rigid inspection and tests<br />

assure uninterrupted, dependable service.<br />

ELECTROMAGNETIC<br />

Laminations - laminations are constructed<br />

of high-grade steel, annealed and treated to<br />

assure lowest wattage losses. They are precision<br />

stamped with carbide steel dies for<br />

positive, tight stacking to provide consistent<br />

electrical characteristics.<br />

Coils - highest quality annealed wire is<br />

used in the precision winding of all coils.<br />

Uniform, firmly wound coils assure consistent<br />

operating characteristics.<br />

Complete core & coil assembly is vacuum<br />

impregnated with an exclusive <strong>Advance</strong><br />

asphalt-wax impregnant.<br />

Lead Wire - PVC covered solid lead wire is<br />

firmly anchored to the coils to facilitate positive<br />

and permanent connections.<br />

Supply Voltage and Frequency<br />

Each ballast is designed to operate at the nominal<br />

voltage shown on the ADVANCE label. Abnormal deviation<br />

from these values will result in damage to either<br />

the ballast or lamp or both. It is therefore necessary<br />

that the voltage applied to ballasts be maintained within<br />

the respective limits shown in the adjoining table.<br />

A ballast subjected to higher than nominal voltages<br />

will operate at increased temperatures. This will result<br />

in reduced ballast life. Low voltage can cause premature<br />

lamp failures as well as unreliable lamp starting.<br />

All ballasts are designed for single frequency operation.<br />

Therefore, best results will be obtained when that<br />

ballast is used on the frequency shown on the ballast<br />

label. Frequency limitations are as follows:<br />

Nominal Frequency Limits<br />

60HZ 57.5 to 62.5<br />

50HZ 47.5 to 52.5<br />

Prefix<br />

Code<br />

Letters<br />

Normal<br />

Voltage<br />

Applied Voltage<br />

Limits<br />

Color Label<br />

Identification<br />

H 120 112-127 YELLOW<br />

R 120 112-127 YELLOW<br />

L 120 112-127 YELLOW<br />

S 120 112-127 YELLOW<br />

X 220 210-230 GREEN<br />

M 220/250 210-230 / 235-260 —<br />

Y 240 225-250 ORANGE<br />

V 277 255-290 RED<br />

G 347 322-365 GRAY<br />

3-2<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


ELECTROMAGNETIC BALLASTS<br />

Ballast Date Codes<br />

<strong>Advance</strong> electromagnetic<br />

fluorescent lamp ballasts are<br />

date stamped on the ballast<br />

cover to designate month<br />

and year of manufacture. The<br />

month is indicated first, followed<br />

by the year. In the<br />

example shown (1-00), the<br />

manufacturing date is<br />

January, 2000. See page 8-ii for warranty information.<br />

Certifications<br />

Indicates ballast is listed with Underwriters<br />

Laboratories, Inc. and complies with UL935 Standard<br />

for Fluorescent -Lamp <strong>Ballasts</strong> (File No. E14927).<br />

U.L. RECOGNIZED<br />

Indicates ballast is component recognized with<br />

UL. and complies with UL935 Standard for<br />

Fluorescent -Lamp <strong>Ballasts</strong> (File No. E14927).<br />

Visit www.ul.com to find a current listing of<br />

<strong>Advance</strong> ballasts under File No. E14927.<br />

Indicates ballast is certified by Cnadian Standards<br />

Association and complies with CAN/CSA-22.2 No.<br />

74-92 for Fluorescent-Lamp <strong>Ballasts</strong> (File No.<br />

LR7310).<br />

Indicates ballast complies with U.S. Energy<br />

Standards.<br />

Indicates ballast complies with Canadian Energy<br />

Standards.<br />

<strong>Advance</strong> fluorescent ballasts are designed<br />

and manufactured in accordance with the<br />

American National Standards Institute<br />

standard for fluorescent ballasts, ANSI C82.1.<br />

Class P <strong>Ballasts</strong> — <strong>Section</strong> 410-73(e) of the National<br />

<strong>Electric</strong>al Code (NEC) requires that all indoor fluorescent fixtures<br />

shall incorporate ballast protection. Those fixtures employing a<br />

simple reactive type ballast are exempted.<br />

The protector is located within the ballast case to prevent<br />

physical damage and tampering.<br />

<strong>Advance</strong> electromagnetic ballasts ordered with ADVAN-guard ®<br />

Class P ballast protection (TP suffix) are equipped with a thermally<br />

actuated automatic reclosing protective device. This revolutionary<br />

development was originally designed and introduced by <strong>Advance</strong>,<br />

and today this Class P device is a requirement of the National<br />

<strong>Electric</strong>al Code in all indoor lighting installations.<br />

Safety<br />

The National <strong>Electric</strong>al Code requires grounding of fluorescent<br />

fixtures. The fluorescent ballast case must be grounded either to<br />

the fluorescent fixture or, if remote mounted, by other means<br />

such as a wire from the ballast case to ground. Without proper<br />

fixture and ballast grounding, a shock hazard may exist due to<br />

the fluorescent fixture becoming energized by an internal ballast<br />

failure to case. Also, all ballasts have normal leakage current.<br />

When the ballast is properly grounded, the leakage current does<br />

not constitute a hazard.<br />

Starting<br />

The metal of a fluorescent fixture is a starting aid when properly<br />

grounded. T12 Fluorescent lamps rated at 40 watts or less<br />

used for rapid or trigger start operation must be mounted within<br />

1/2” of a grounded metal surface. T8 Lamps must be mounted<br />

within 3/4” of a grounded metal surface. All other lamps must<br />

be mounted within 1” of a grounded metal surface.<br />

An important additional factor for proper lamps starting is<br />

polarity. The white ballast lead must be connected to the ground<br />

of the power supply (neutral) and the black lead to the hot line<br />

wire. A reversal of polarity may result in lamp damage or improper<br />

lamp starting.<br />

Cold Weather Operation<br />

Lumen ratings of fluorescent lamps apply for operation in still<br />

air at a temperature of 77°F. While many fluorescent lamps and<br />

fluorescent lamp ballasts are designed to give their best performance<br />

at 77°F, they will provide reasonably good light output<br />

down to 50°F. Further decreases in ambient temperature will<br />

result in decreased light output.<br />

Variables such as humidity, line voltage, fixture design and<br />

variations within the particular design of the lamp and the fluorescent<br />

lamp ballast play an important part in determining the<br />

low temperature starting limit.<br />

These are the two considerations for low temperature application:<br />

1. Starting of the lamps<br />

Low temperatures change the electrical starting characteristics<br />

of a fluorescent lamp. As the fluorescent lamp becomes<br />

colder, it becomes more difficult to start. Therefore, a fluorescent<br />

ballast must have a higher starting voltage; thus, follow<br />

the temperature recommendations shown in the tables.<br />

<strong>Ballasts</strong> designed for low temperature use ensure reliable<br />

starting only and not the light output.<br />

2. Operating the lamps<br />

The light output of any fluorescent lamp depends on the<br />

mercury vapor pressure within the lamp. Maximum light<br />

output for most fluorescent lamps occurs when the bulb<br />

temperature is about 100°F. As bulb wall temperature goes<br />

above 100°F the mercury vapor pressure within the tube<br />

increases and the light output decreases.<br />

Interestingly enough, at lower bulb-wall temperatures,<br />

the mercury condenses on the tube, pressure drops and the<br />

light output again decreases. This is inherent in all fluorescent<br />

lamps. In order to prevent reduction in light output at<br />

low temperatures the lamp should be enclosed so it has a<br />

chance to overcome the low bulb-wall temperature by the<br />

heat generated by the lamp.<br />

In general, outdoor lighting installations have tended toward<br />

800 and 1500mA lamps since the additional heat generated by<br />

these lamps will provide better illumination in cold weather than<br />

can be obtained with 430mA lamps. The 430mA lamps are not recommended<br />

by the lamp manufacturer for starting conditions<br />

below 0°F. Above this temperature,shielding is required to a<br />

greater degree than with the more heavily loaded lamps. Special<br />

low temperature lamps, which may be purchased with shields, are<br />

available for 1500mA operation.<br />

ELECTROMAGNETIC<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 3-3


ELECTROMAGNETIC BALLASTS<br />

Ballast Sound<br />

The slight hum present in fluorescent lighting installations<br />

originates from the inherent magnetic action in the core & coil<br />

assembly of the ballasts. This hum may be amplified by the<br />

method of mounting the ballast in the fixture...the fixture<br />

design...and, more often than not, this hum is amplified by the<br />

resonant qualities of the ceiling, walls, floors and furniture. In<br />

planning a lighting installation, careful consideration must be<br />

given to the selection of the fluorescent lamp ballast, the lighting<br />

fixture and room components. These precautions will ensure the<br />

quietest installation possible.<br />

The choice of fluorescent lamp ballast should be made on the<br />

basis of selecting the one rated quietest for a specific location or<br />

interior as some ballast have a more discernable hum due to<br />

basic construction features and electrical ratings.<br />

It is therefore essential that a ballast which is placed in an<br />

enclosure be suitably ventilated. Where more than one ballast is<br />

installed in an enclosure, the ballast should be positioned far<br />

enough apart to provide adequate heat dissipation.<br />

To assist in limiting the temperature rise of ballasts, the following<br />

procedures are recommended:<br />

• Mount ballast with maximum number of sides in direct<br />

contact with the metal channel of fixture. Radiators are<br />

an excellent way of dissipating heat.<br />

• Provide fixture ventilation.<br />

• Paint the unpainted fixture channels with a non-metallic<br />

finish to increase radiation.<br />

SOUND RATINGS<br />

• Place ballast in a cooler location outside the fixture.<br />

ELECTROMAGNETIC<br />

For any Installation in:<br />

TV or Radio Station,<br />

Library, Reception or<br />

Reading Room, Church,<br />

School Study Hall<br />

Average Ambient<br />

Noise Level<br />

Of Interior<br />

20-24<br />

DECIBELS<br />

Residence, Quiet Office, 25-30<br />

Night School Classroom DECIBELS<br />

General Office Area,<br />

Commercial Building,<br />

Storeroom<br />

31-36<br />

DECIBELS<br />

Sound<br />

Level<br />

Rating*<br />

A<br />

B<br />

C<br />

• Place fixture to attain maximum dissipation of heat by<br />

conduction, convection or radiation.<br />

BALLAST TYPE<br />

Magnetic = Standard electromagnetic core and coil construction<br />

continues to provide reliable service and economy over a wide<br />

variety of lighting system applications. Operates lamps at 60 Hz.<br />

Mark III = Energy-saving electromagnetic ballast designed to<br />

provide 10% energy savings over corresponding standard magnetic<br />

units while maintaining equivalent full light output.<br />

Operates lamps at 60 Hz.<br />

E-PAK = Energy-saving electromagnetic ballast specifically optimized<br />

for energy saving lamps to provide 17% energy savings<br />

over corresponding standard magnetic units while maintaining<br />

equivalent light output. Operates lamps at 60 Hz.<br />

Manufacturing Facility,<br />

Retail Store,<br />

Noisy Office<br />

37-42<br />

DECIBELS<br />

D<br />

*These sound ratings are based on measurements of Average Ambient<br />

noise levels during conditions of normal occupancy. Audible ballast hum<br />

may appear amplified during exceptionally quiet periods and at times when<br />

area is unoccupied.<br />

Temperature and Ventilation<br />

Underwriters’ Laboratories, Inc. stipulates that the temperature<br />

limitation of a fluorescent lamp ballast using Class A insulation<br />

at normal operation should have a maximum ballast coil<br />

temperature of 105°C (221°F) and maximum ballast case temperature<br />

of 90°C (194°F) at its hottest spot. Ballast life will be<br />

reduced if it is operated at a temperature above these limits.<br />

A fluorescent lamp ballast, like other electrical equipment,<br />

generates heat during normal operation. If not maintained within<br />

prescribed limits, this heat will become the primary cause of<br />

reduced ballast life. Heat generated in the conventional ballast is<br />

transferred to the case through a silica compound which totally<br />

surrounds the internal components and is then dissipated to the<br />

surrounding air or mounting surface by conduction, convection<br />

or radiation.<br />

3-4<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


ELECTROMAGNETIC BALLASTS<br />

Straight<br />

Rapid Start Lamps<br />

T4 T8 T5<br />

and<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim.<br />

Wiring<br />

Dia.<br />

F17T8 (265mA)<br />

1 17 50<br />

2 17 50<br />

120 R-1P817-TP ✓ ✓ 0.21 24 1.01


T5HO T8<br />

CENTIUM ®<br />

ELECTROMAGNETIC BALLASTS<br />

U-Shaped<br />

Rapid Start Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim.<br />

Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

RAPID START<br />

FBO16T8 (265mA)<br />

1 16 50<br />

120 R-1P817-TP ✓ ✓ 0.20 23 0.98


ELECTROMAGNETIC BALLASTS<br />

Straight<br />

Rapid Start Lamps<br />

T4 T10 T5<br />

and<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim.<br />

Wiring<br />

Dia.<br />

F40T10 (420mA)<br />

120 R-140-TP Mark III R ✓ ✓ ✓ ✓ 0.46 53 0.95


T12<br />

ELECTROMAGNETIC BALLASTS<br />

Straight<br />

Rapid Start Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTROMAGNETIC<br />

RAPID START<br />

Lamp Data Min.<br />

Starting<br />

Number Watts Temp.<br />

(F)<br />

F25T12 (455mA)<br />

1 25 60<br />

2 25 60<br />

F30T12 (430mA)<br />

1 30 50<br />

2 30 50<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

120 HM-1P30-TP ✓ ✓ 0.34 40 0.91


10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

ELECTROMAGNETIC BALLASTS<br />

Straight<br />

Rapid Start Lamps<br />

T12<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data Min.<br />

Starting<br />

Number Watts Temp.<br />

(F)<br />

F34T12 (460mA)<br />

● Sound Rated B<br />

✪ For Residential Use Only<br />

LINE<br />

BLUE<br />

BLUE<br />

WHITE<br />

BLK/WHT<br />

LAMP<br />

BALLAST<br />

Diag. 20<br />

Input<br />

Volts<br />

❉ Normal Power Factor<br />

R For Replacement Use Only<br />

RED<br />

RED<br />

Catalog<br />

Number<br />

Certifications<br />

DIMENSIONS<br />

Designation<br />

Length (L)<br />

(inches)<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

120 R-140-TP Mark III R ✓ ✓ ✓ ✓ 0.38 43 0.88


10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

T12<br />

ELECTROMAGNETIC BALLASTS<br />

Straight<br />

Rapid Start Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

ELECTROMAGNETIC<br />

RAPID START<br />

Lamp Data<br />

Number<br />

Watts<br />

F40T12 (430mA)<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

1 40 50<br />

2 40 50<br />

Input<br />

Volts<br />

120<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

R-140-TP Mark III R ✓ ✓ ✓ ✓ 0.43 50 0.95


ELECTROMAGNETIC BALLASTS<br />

U-Shaped<br />

Rapid Start Lamps<br />

T12<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

F34T12/U (460mA)<br />

1 34 60<br />

2 34 60<br />

F40T12/U (430mA)<br />

1 40 50<br />

2 40 50<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

120 R-1U40-T0P Mark III R ✓ ✓ ✓ 0.39 44 0.93


T12<br />

Dimming<br />

ELECTROMAGNETIC BALLASTS<br />

Straight & U-Shaped<br />

Rapid Start Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F40T12 (430mA)<br />

F40T12/U (430mA)<br />

1<br />

2<br />

40<br />

40<br />

50<br />

50<br />

120<br />

120<br />

Data listed is for full light output<br />

Line Current Controlled by Control Setting<br />

Dimming Range-100%—5%<br />

All Require Circuit Interrupting Lampholders<br />

Note: Will NOT Operate 34W Energy Saver Lamps<br />

DIM-140-H-TP ✓ ✓ 0.52 58 1.00


ELECTROMAGNETIC BALLASTS<br />

High Output<br />

Rapid Start Lamps<br />

T12/HO<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F24T12/HO (800mA)<br />

1 35 -20<br />

120 RS-110-TP ● ✓ ✓ 0.58 63 0.93


T12/HO<br />

ELECTROMAGNETIC BALLASTS<br />

High Output<br />

Rapid Start Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim.<br />

Wiring<br />

Dia.<br />

F42T12/HO (800mA)<br />

1 55 -20<br />

2 55 -20<br />

120 RS-110-TP ● ✓ ✓ 0.69 80 0.96


ELECTROMAGNETIC BALLASTS<br />

High Output<br />

Rapid Start Lamps<br />

T12/HO<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F60T12/HO (800mA)<br />

120<br />

RS-110-TP ● ✓ ✓ 0.83 97 0.93


T12/HO<br />

ELECTROMAGNETIC BALLASTS<br />

High Output<br />

Rapid Start Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

HIGH OUTPUT<br />

F72T12/HO (800mA)<br />

120<br />

RC-2S85-TP ✓ ✓ 0.98 100 0.82


ELECTROMAGNETIC BALLASTS<br />

High Output<br />

Rapid Start Lamps<br />

T12/HO<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F96T12/HO Energy Saver (840mA)<br />

120 RS-110-TP ● ✓ ✓ 1.00 121 0.94


T10 and T12/VHO<br />

ELECTROMAGNETIC BALLASTS<br />

Very High Output<br />

VHO & Powergroove Rapid Start Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED D<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

VERY HIGH OUTPUT<br />

F48T10/VHO (1500mA)<br />

F48T12/VHO (1500mA)<br />

F48PG17/VHO (1500mA)<br />

1<br />

2<br />

116<br />

116<br />

-20<br />

-20<br />

120<br />

120<br />

RC-2S102-TP<br />

RC-2S102-TP<br />

✓<br />

✓<br />

✓<br />

✓<br />

1.70<br />

2.20<br />

130<br />

230<br />

0.87<br />

0.89<br />


ELECTROMAGNETIC BALLASTS<br />

Very High Output<br />

VHO & Powergroove Rapid Start Lamps<br />

T10 and T12/VHO<br />

HIGH POWER FACTOR<br />

SOUND RATED D<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F96T12/VHO Energy Saver (1580mA)<br />

F96PG17/VHO Energy Saver (1580mA)<br />

1 185 60<br />

120 RC-2S102-TP ✓ ✓ 2.00 198 0.87


T6,T8,T12<br />

ELECTROMAGNETIC BALLASTS<br />

Slimline & Instant Start<br />

Instant Start Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F42T6 (200mA)<br />

1 25 0 120 SM-151-S-TP ✓ ✓ 0.42 45 1.00


ELECTROMAGNETIC BALLASTS<br />

Slimline & Instant Start<br />

Instant Start Lamps<br />

T12 and T17<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F24T12 (425mA)<br />

1 20 0 120 SM-140-S-TP ✓ ✓ 0.45 45 0.93


T12 SLIMLINE<br />

ELECTROMAGNETIC BALLASTS<br />

Slimline<br />

Instant Start Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F60T12 (425mA)<br />

1<br />

2<br />

50<br />

50<br />

0<br />

0<br />

120 RSM-175-S-TP ✓ ✓ 0.74 73 0.93


ELECTROMAGNETIC BALLASTS<br />

Slimline<br />

Instant Start Lamps<br />

T12 SLIMLINE<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F96T12 Energy Saver (440mA)<br />

1 60 60<br />

120 RSM-175-S-TP ✓ ✓ 0.68 74 0.88


T5<br />

ELECTROMAGNETIC BALLASTS<br />

Preheat Lamps<br />

Preheat <strong>Ballasts</strong> (Starter Required)<br />

✩<br />

CLASS B INSULATION NORMAL POWER FACTOR SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

PREHEAT<br />

F4T5<br />

1<br />

F6T5<br />

1<br />

F8T5<br />

4<br />

6<br />

50<br />

50<br />

120<br />

120<br />

LPL-5-9 ◆✖❏<br />

LPL-5-9 ◆✖❏<br />

✓<br />

✓<br />

✓<br />

✓<br />

0.19<br />

0.17<br />

9<br />

9<br />

1.01<br />

1.02<br />


ELECTROMAGNETIC BALLASTS<br />

Preheat Lamps<br />

Preheat <strong>Ballasts</strong> (Starter Required)<br />

✩<br />

T8<br />

CLASS B INSULATION NORMAL POWER FACTOR SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F13T8<br />

1 13 50 120 LO-13-22 ◆✖❏ ✓ ✓ 0.34 17 0.91


T12<br />

ELECTROMAGNETIC BALLASTS<br />

Preheat Lamps<br />

Preheat <strong>Ballasts</strong> (Starter Required)<br />

✩<br />

CLASS B INSULATION NORMAL POWER FACTOR SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

PREHEAT<br />

F14T12<br />

1<br />

F15T12<br />

14 50 120<br />

LO-13-22 ✖◆❏ ✓ ✓ 0.34 18 0.92


ELECTROMAGNETIC BALLASTS<br />

Preheat Lamps<br />

Trigger Start <strong>Ballasts</strong><br />

T5 and T8<br />

NORMAL POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F4T5 4W<br />

F6T5 6W<br />

F8T5 8W<br />

1 8 50<br />

120 LQ-106F-TP ✓ 0.34 14 0.86


T12<br />

ELECTROMAGNETIC BALLASTS<br />

Preheat Lamps<br />

Trigger Start <strong>Ballasts</strong><br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

PREHEAT<br />

❖<br />

❉<br />

F14T12<br />

1 14<br />

50 RLQ-120-TP ❖❉ ✓ ✓ 0.58 28 0.92


T12<br />

ELECTROMAGNETIC BALLASTS<br />

Preheat Lamps<br />

Trigger Start <strong>Ballasts</strong><br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

PREHEAT<br />

❖<br />

❉<br />

F14T12<br />

1 14<br />

50 RLQ-120-TP ❖❉ ✓ ✓ 0.58 28 0.92


T9<br />

ELECTROMAGNETIC BALLASTS<br />

Circline Lamps<br />

Rapid Start <strong>Ballasts</strong><br />

NORMAL POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

CIRCLINE<br />

FC6T9 (20W Circline)<br />

1 20 50 120 RLQS-122-TP-W ✓ ✓ 0.56 24 0.76


ELECTROMAGNETIC BALLASTS<br />

2-Pin Compact Lamps<br />

Preheat <strong>Ballasts</strong><br />

T4<br />

CLASS B INSULATION NORMAL POWER FACTOR SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line Current (Amps)<br />

Operating Starting<br />

Open<br />

Circuit<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

% Dim. Wiring<br />

Dia.<br />

CFT5W/G23 - 5W Twin Tube Lamp (PL-S5W, F5BX, CF5DS)<br />

1 5 0 120 LPL-5-9-TP ◆ ❏ ✓ ✓ 0.19 0.19 — 9 1.06


T4 and T5<br />

ELECTROMAGNETIC BALLASTS<br />

2-Pin Compact & 4-Pin Long Twin Tube Lamps<br />

Preheat <strong>Ballasts</strong><br />

CLASS B INSULATION NORMAL POWER FACTOR SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line Current (Amps)<br />

Operating Starting<br />

Open<br />

Circuit<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

% Dim. Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

COMPACT<br />

FT18W/2G11 - 18W Long Twin Tube Lamp (PL-L18, F18BX, FT18DL) - Separate Starter Required<br />

1 18 50 120<br />

Above Units Available for Outdoor Fixtures labeled “Outdoor<br />

Use Only.” Eliminate TP from Catalog Number.<br />

◆ Open Core & Coil <strong>Ballasts</strong> are available without mounting feet—<br />

Add Suffix -A to Calalog Number. Units without mounting feet<br />

are UL Component Recognized.<br />

★ Core & Coil with Cover, painted white<br />

ƒ For Outdoor Use Only<br />

WHITE<br />

LINE<br />

BLACK<br />

CAP<br />

OPTIONAL<br />

BALLAST<br />

Diag. 44<br />

S<br />

BLUE<br />

LC-25-TP ★ ✓ ✓ 0.39 0.59 — 22 1.05


ELECTROMAGNETIC BALLASTS<br />

2-Pin Compact Lamps<br />

Preheat <strong>Ballasts</strong><br />

T4<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog ✧<br />

Number<br />

Certifications<br />

Line Current (Amps)<br />

Operating Starting<br />

Open<br />

Circuit<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

% Dim. Wiring<br />

Dia.<br />

CFT5W/G23 - 5W Twin Tube Lamp (PL-S5W, F5BX, CF5DS)<br />

0 L-1B9-TP ❉ ✓ ✓ 0.19 0.20 — 11 1.00


T4<br />

ELECTROMAGNETIC BALLASTS<br />

2-Pin Compact Lamps<br />

Preheat <strong>Ballasts</strong><br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog ✧<br />

Number<br />

Certifications<br />

Line Current (Amps)<br />

Operating Starting<br />

Open<br />

Circuit<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Dim.<br />

Wiring<br />

Dia.<br />

CFQ13W/G24d - 13W Quad Tube Lamp (PL-C13W, F13DBXT4)<br />

1 13 0 120 L-1Q13-TP -W❉ ✓ ✓ 0.35 0.19 — 18 0.93


ELECTROMAGNETIC BALLASTS<br />

2-Pin Compact Lamps<br />

Preheat <strong>Ballasts</strong><br />

T4 and T5<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog✧<br />

Number<br />

Certifications<br />

Line Current (Amps)<br />

Operating Starting<br />

Open<br />

Circuit<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

% Dim. Wiring<br />

Dia.<br />

CFQ18WG24d - 18W Quad Tube Lamp (PL-C18W, F18DBXT4, CF18DD)<br />

CFTR18W/GX24d - 18W Triple Tube Lamp (CF18DT)<br />

1 18 50<br />

120<br />

L-1Q18-TP ❉ ✓ ✓ 0.48 0.27 — 25 0.96


T4 and T6<br />

ELECTROMAGNETIC BALLASTS<br />

2D Square Shaped Lamps<br />

Preheat <strong>Ballasts</strong><br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog✧<br />

Number<br />

Certifications<br />

Line Current (Amps)<br />

Operating Starting<br />

Open<br />

Circuit<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

% Dim. Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

COMPACT<br />

CFS21W/GR10q - 21W 2D Lamp (F21 2D/4P) - Separate Starter Required<br />

L-1Q26-TP ❉ ✓ ✓ 0.66 0.46 — 32 0.98<br />

1 21 25 120<br />

H-1Q26-TP ✓ ✓ 0.23 0.33 0.41 26 0.82<br />

CFS28W/GR8 - 28W 2D Lamp (F28 2D)<br />

L-140-F-TP ❉ ✓ ✓ 0.70 — — 39 0.94<br />

1 28 25 120 L-1Q26-TP ❉ ✓ ✓ 0.63 0.46 — 35 0.97<br />

H-1Q26-TP ✓ ✓ 0.24 0.33 0.41 28 0.80<br />

CFS28W/GR10q - 28W 2D Lamp (F38 2D/4P) - Separate Starter Required<br />

1 28 50 120 LX-140-F-TP ❉ ✩ ✓ ✓ 0.63 — — 40 1.02<br />

✧ Ordering Information<br />

Add suffix -W to Catalog Number for white can<br />

with leads exiting end of ballast.<br />

Add suffix -BLS to Catalog Number for black can<br />

with bottom leads and studs.<br />

❉ Normal Power Factor<br />

✩ Ballast includes built-in starter<br />

BLK/WHT<br />

BLACK<br />

DIMENSIONS<br />

Designation<br />

Length (L)<br />

(inches)<br />

Width (W)<br />

(inches)<br />

Height (H)<br />

(inches)<br />

Mounting (M)<br />

(inches)<br />

R-4 6¹₂ 1¹⁵₁₆ 1³₈ 6 +<br />

T-1 6¹₂ 2³⁄₈ 1¹⁄₂ 6 +<br />

+ Mounting dimensions refer to slots only<br />


ELECTROMAGNETIC BALLASTS<br />

Long Twin Tube Lamps<br />

Rapid Start <strong>Ballasts</strong><br />

FT5<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

FT18W/2G11/RS - 18W Long Twin Tube Lamp (F18BX/RS, FT18DL/RS)<br />

1<br />

2<br />

18<br />

18<br />

50<br />

50<br />

120<br />

120<br />

R-1P817-TP<br />

R-2P817-TP<br />

✓<br />

✓<br />

✓<br />

✓<br />

0.22<br />

0.41<br />

25<br />

47<br />

1.01<br />

0.98<br />


T12/HO<br />

Weatherproof<br />

ELECTROMAGNETIC BALLASTS<br />

High Output<br />

Rapid Start Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

ELECTROMAGNETIC<br />

WEATHERPROOF<br />

F24T12/HO (800mA)<br />

2 35 -20 120 RC-2S85-FO ✓ 1.01 95 0.78


ELECTROMAGNETIC BALLASTS<br />

Very High Output<br />

VHO & Powergroove Rapid Start Lamps<br />

T10 and T12/VHO<br />

HIGH POWER FACTOR<br />

SOUND RATED D<br />

Weatherproof<br />

Lamp Data<br />

Number<br />

Watts<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

THD<br />

%<br />

Power<br />

Factor<br />

Dim. Wiring<br />

Dia.<br />

F48T10/VHO (1500mA)<br />

F48T12/VHO (1500mA)<br />

F48PG17/VHO (1500mA)<br />

1 116 -20<br />

120 RC-2S102-FO ✓ 1.70 130 0.87


T12/HO<br />

Sign<br />

ELECTROMAGNETIC BALLASTS<br />

High Output<br />

Rapid Start Lamps<br />

CLASS P BALLAST IN WHITE CAN<br />

Lamp Data<br />

No. of Lamp Footage<br />

Lamps Min Max<br />

Min.<br />

Starting<br />

Temp.<br />

(F)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Certifications<br />

Max. Line<br />

Current<br />

(Amps)<br />

Max. Input<br />

Power<br />

(Watts)<br />

Open<br />

Circuit<br />

Volts<br />

Dim.<br />

Wiring<br />

Dia.<br />

T12/HO (800mA)<br />

1,2<br />

2, 3, 4<br />

2, 3, 4<br />

2, 3, 4<br />

4<br />

6<br />

12<br />

20•<br />

12<br />

20<br />

24<br />

40•<br />

-20°F<br />

120<br />

277<br />

120<br />

277<br />

120<br />

277<br />

120<br />

277<br />

ASB-0412-12-BL-TP<br />

VSB-0412-12-BL-TP<br />

ASB-0620-24-BL-TP<br />

VSB-0620-24-BL-TP<br />

ASB-1224-24-BL-TP<br />

VSB-1224-24-BL-TP<br />

ASB-2040-24-BL-TP<br />

VSB-2040-24-BL-TP<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

1.48<br />

0.65<br />

2.56<br />

1.12<br />

2.70<br />

1.15<br />

4.00<br />

1.75<br />

175<br />

304<br />

312<br />

472<br />

480<br />

720<br />

785<br />

720<br />

BL-1<br />

BL-1<br />

BL-2<br />

BL-3<br />

21, 39<br />

5, 8, 13<br />

7, 9, 13<br />

5, 9, 13<br />

3, 4<br />

24<br />

32<br />

120<br />

ASB-2432-34-BL-TP<br />

✓<br />

✓<br />

3.30<br />

370<br />

975<br />

BL-4<br />

8, 13<br />

ELECTROMAGNETIC<br />

SIGN<br />

120 ASB-1240-46-BL-TP ✓ ✓<br />

4, 5, 6 12▼ 40▼<br />

277 VSB-1240-46-BL-TP ✓ ✓<br />

120 ASB-2448-46-BL-TP ✓ ✓<br />

4, 5, 6 24■ 48■<br />

277 VSB-2448-46-BL-TP ✓ ✓<br />

● Total lamp length of each circuit (A) and (B) must not be less than 10 ft. nor more than 20 ft.<br />

Circuit (A) is comprised of lamps 1,2. Circuit (B) is comprised of lamps 3,4. (See wiring diagrams).<br />

▼ Total lamp length of each circuit (A) and (B) must not be less than 6 ft. nor more than 20 ft.<br />

Circuit (A) is comprised of lamps 1,2,3. Circuit (B) is comprised of lamps 4,5,6. (See wiring diagrams).<br />

■ Total lamp length of each circuit (A) and (B) must not be less than 12 ft. nor more than 24 ft.<br />

Circuit (A) is comprised of lamps 1,2,3. Circuit (B) is comprised of lamps 4,5,6. (See wiring diagrams).<br />

3.90<br />

1.70<br />

5.19<br />

2.25<br />

462<br />

604<br />

720<br />

720<br />

BL-3<br />

BL-3<br />

14, 15, 19<br />

14, 15, 19<br />

LAMP<br />

BALLAST<br />

LINE<br />

BLACK<br />

WHITE<br />

BROWN<br />

BROWN<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

BLUE-WH<br />

BLUE-WH<br />

RED<br />

YELLOW<br />

RED<br />

LINE<br />

* YEL<br />

* YEL<br />

WHITE<br />

BLACK<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

LAMP 2<br />

*FOR INSULATE<br />

*FOR SINGLE LAMP OPERATION, INSULATE<br />

FOR 600V<br />

YELLOW LEADS INDIVIDUALLY FOR 600V<br />

Diag. 39<br />

Diag. 39<br />

Note: insulate unused leads individually<br />

as shown on ballast label<br />

Diag. 5<br />

LAMP 3<br />

Note: insulate unused leads individually<br />

as shown on ballast label<br />

Diag. 7<br />

Note: Insulate unused leads individually as shown on ballast label<br />

Diag. 7<br />

LINE<br />

BLACK<br />

WHITE<br />

BROWN<br />

BROWN<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

BLUE-WH<br />

BLUE-WH<br />

RED<br />

RED<br />

LINE<br />

BLACK<br />

WHITE<br />

BROWN<br />

BROWN<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

BLUE-WH<br />

BLUE-WH<br />

RED<br />

RED<br />

LINE<br />

BLACK<br />

WHITE<br />

BROWN<br />

BROWN<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

BLUE-WH<br />

BLUE-WH<br />

RED<br />

RED<br />

LINE<br />

BLACK<br />

WHITE<br />

BROWN<br />

BROWN<br />

BLUE-WH<br />

BLUE-WH<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

OR-BLK<br />

OR-BLK<br />

ORANGE<br />

ORANGE<br />

RED<br />

RED<br />

LAMP 1<br />

LAMP 1<br />

LAMP 1<br />

LAMP 2<br />

LAMP 3<br />

LAMP 2<br />

LAMP 2<br />

LAMP 3<br />

LAMP 3<br />

LAMP 3<br />

LAMP 4<br />

Note: Insulate unused Note: leads insulate individually as unused shown on ballast leads labelindividually<br />

Diag. 8<br />

as shown on ballast label<br />

Diag. 8<br />

LAMP 4<br />

Note: insulate unused leads individually<br />

as shown on ballast label<br />

Diag. 9<br />

Note: Insulate unused leads individually as shown on ballast label<br />

Diag. 9<br />

LAMP 4<br />

Diag. 13<br />

LAMP 6<br />

Note: Insulate unused leads individually as shown on ballast label<br />

Note: insulate unused leads individually<br />

as shown on ballast label<br />

Diag. 14<br />

Diag. 14<br />

LINE<br />

BLACK<br />

WHITE<br />

BROWN<br />

BROWN<br />

BLUE-WH<br />

BLUE-WH<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

OR-BLK<br />

OR-BLK<br />

ORANGE<br />

ORANGE<br />

RED<br />

RED<br />

LINE<br />

BLACK<br />

WHITE<br />

BROWN<br />

BROWN<br />

BLUE-WH<br />

BLUE-WH<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

OR-BLK<br />

OR-BLK<br />

ORANGE<br />

ORANGE<br />

RED<br />

RED<br />

LAMP 1<br />

LAMP 1<br />

LAMP 2<br />

LAMP 3<br />

LAMP 3<br />

LAMP 4<br />

LAMP 4<br />

LAMP 5<br />

LAMP 5<br />

3-40<br />

LAMP 6<br />

Note: Insulate unused leads individually as shown on ballast label<br />

Note: insulate unused leads individually<br />

as shown on ballast label<br />

Diag. 15<br />

Diag. 15<br />

LAMP 6<br />

Diag. 19<br />

Diag. 19<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


ELECTROMAGNETIC BALLASTS<br />

High Output<br />

Rapid Start Lamps<br />

CLASS P BALLAST IN WHITE CAN<br />

T12/HO<br />

Sign<br />

Total Lamp Feet<br />

Number of Lamps<br />

per Ballast<br />

1,2<br />

2,3,4<br />

2,3,4<br />

2,3,4<br />

3,4<br />

4,5,6<br />

4,5,6<br />

To select the ballast for your particular plastic sign application:<br />

1) Determine the total number of lamp feet required (from 4 to 48 feet) and read down to select the proper <strong>Advance</strong> Catalog Number. Note<br />

that the first ballast you come to, reading down the chart, will be the most economical for your application.<br />

2) The number of lamps per ballast is shown in the left column.<br />

DIMENSIONS<br />

PC-161W<br />

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50<br />

ASB-0412-12-BL-TP<br />

VSB-0412-12-BL-TP<br />

ASB-0620-24-BL-TP<br />

VSB-0620-24-BL-TP<br />

ASB-1224-24-BL-TP<br />

VSB-1224-24-BL-TP<br />

ASB-2040-24-BL-TP<br />

VSB-2040-24-BL-TP<br />

ASB-2432-34-BL-TP<br />

PC-857W<br />

ASB-1240-46-BL-TP<br />

VSB-1240-46-BL-TP<br />

Designation<br />

Length (L)<br />

(inches)<br />

ASB-2448-46-BL-TP<br />

VSB-2448-46-BL-TP<br />

H<br />

Width (W)<br />

(inches)<br />

C<br />

Height (H)<br />

(inches)<br />

Mounting (M)<br />

(inches)<br />

BL-1 11³₄ 3³₁₆ 2⁵₈ 11⁹₆₄<br />

BL-2 14⁵₁₆ 3³₁₆ 2⁵₈ 13³₄<br />

BL-3 19³₁₆ 3³₁₆ 2¹¹₁₆ 18⁵₈<br />

BL-4 16¹¹₁₆ 3³₁₆ 2⁵₈ 16⁹₆₄<br />

ELECTROMAGNETIC<br />

SIGN<br />

Case BL-1, BL-2, BL-3<br />

HID SIGN BALLASTS___________________________________________________________<br />

Input<br />

Voltage<br />

Circuit<br />

Type<br />

Catalog<br />

Number<br />

Operating<br />

150 Watt Lamp, ANSI Code M102 (Medium Base)<br />

120 HX-HPF ASB-150-M102-BL 1.60 1.50 3.65 180 240 10 BL-2 13.00 10<br />

60HZ., minimum starting temperature -20Þ F or -30Þ C.<br />

Input Amps<br />

Starting<br />

Open<br />

Circuit<br />

Input<br />

Watts<br />

Nom.<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

Amps<br />

W 2"<br />

Dimensions<br />

L<br />

M<br />

Certification<br />

Total<br />

Wt.<br />

(Lbs)<br />

Max. Ballast<br />

to Lamp<br />

Distance (ft)<br />

Wiring Diagram<br />

All leads lengths 12”<br />

Ground case<br />

BALLAST<br />

120V Common<br />

Blk<br />

White<br />

Red<br />

Lamp<br />

DIMENSIONS<br />

Designation<br />

Length (L)<br />

(inches)<br />

Width (W)<br />

(inches)<br />

Height (H)<br />

(inches)<br />

Mounting (M)<br />

(inches)<br />

BL-2 14⁵₁₆ 3³₁₆<br />

2⁵₈ 13³₄<br />

Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

3-41


ELECTRONIC HID BALLASTS<br />

ELECTRONIC HID<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


ELECTRONIC HID BALLASTS<br />

Contents<br />

General Information............................................................................4-2<br />

e-Vision ® ...................................................................................4-3 to 4-7<br />

DynaVision ..........................................................................4-8 to 4-10<br />

ELECTRONIC HID<br />

Corporate Offices<br />

(800) 322-2086<br />

Customer Support/Technical Service<br />

(800) 372-3331 • (+) 1 847 390-5000 (International)<br />

Visit our web site at www.advancetransformer.com<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 4-1


ELECTRONIC HID BALLASTS<br />

Just as electronic ballast technology enhanced fluorescent lighting systems, electronic HID<br />

ballasts bring significant performance improvements to HID lighting systems:<br />

• Higher efficiency<br />

• Greater lumen maintenance<br />

• Longer lamp life<br />

• Enhanced color control<br />

Low frequency electronic ballasts are recommended by lamp manufacturers to drive the<br />

new generation of ceramic, low wattage metal halide lamps. These ceramic lamps have<br />

superior color rendition and can potentially maintain that color over the life of the lamps.<br />

However, as color is a function of lamp wattage, the ballast must be able to maintain<br />

lamp wattage precisely at its rated point throughout the entire life of the lamp. Low<br />

frequency electronic HID ballasts such as <strong>Advance</strong> Transformer’s e-Vision ® line<br />

constantly measure and adjust the wattage, optimizing delivery of the ceramic lamps’<br />

superior color properties. This makes metal halide a viable choice for many<br />

applications previously lit by either tungsten halogen or incandescent sources, such as<br />

retail lighting.<br />

Operational improvements are gained as greater efficiency and cooler running electronic<br />

ballasts lead to energy savings. In addition, ballasts run quieter, weigh less and have<br />

compact footprints.<br />

ELECTRONIC HID<br />

Improved lumen maintenance – the lamp/ballast system’s ability to minimize light output<br />

depreciation over the life of the lamp – is the most fundamental and significant benefit of<br />

electronic HID ballasts, especially medium wattage, high frequency ballasts such as<br />

<strong>Advance</strong>’s DynaVision ballast. DynaVision delivers a 30-50% improvement in lumen<br />

maintenance over conventional HID systems (magnetic ballasts driving probe-start metal<br />

halide lamps) and a 19% improvement over pulse-start systems. Conventional HID systems<br />

typically experience a 50-60% fall-off in light output over the published life of the lamp. By<br />

maintaining higher light levels across the entire published life of the lamp, electronic HID<br />

ballasts reduce the need for frequent re-lamping.<br />

With more maintained lumens the overall fixture count can be significantly reduced.<br />

For example, a 400w DynaVision system produces up to 56% more mean lumens over a<br />

400w probe-start system with magnetic ballasts. Taking advantage of this performance<br />

benefit, the fixture count can be reduced by up to 36% without sacrificing light levels.<br />

Fewer fixtures also lead to much lower operating costs in terms of both energy<br />

savings and maintenance.<br />

Dimming (to 50% power) with lighting controls such as relays, occupancy sensors,<br />

building management systems (BMS) and, in the future, digitally addressable lighting<br />

systems (such as DALI) are also possible with DynaVision electronic HID ballasts.<br />

The DynaVision ballast also incorporates microprocessor-based technology which provides<br />

comprehensive lamp and ballast parameter control and is a solid platform for the future.<br />

4-2<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


e-Vision® LOW FREQUENCY ELECTRONIC HID BALLASTS<br />

For Low Wattage HID Lamps<br />

Key Features<br />

IntelliVolt ®<br />

• Operates on either 120 or 277 volts, or any<br />

voltage in between, 50 or 60 Hz<br />

Smaller and lighter weight than magnetic HID<br />

F-Can ballasts<br />

Reduced input watts compared to magnetic systems<br />

Low frequency lamp operation<br />

Square wave output waveform<br />

Lamp EOL detection; Safely shuts down system at<br />

lamp end of life<br />

Thermally protected, internally fused, and output<br />

short circuit protected<br />

Excellent lamp wattage regulation<br />

• Lamp wattage will change less than .5% with a<br />

+/-10% change in line voltage<br />

Metallic enclosure<br />

Key Benefits<br />

• Fewer SKUs required in inventory<br />

• Broadens the range of applications<br />

• Compact electronic HID footprints<br />

• Provides greater design flexibility<br />

• Energy Savings; Lower cost of ownership<br />

• Prevents acoustic resonance in the lamp arc tube<br />

• Recommended by lamp manufacturers<br />

• Maximizes lamp life<br />

• Enhanced safety<br />

• Safely shuts system down upon<br />

abnormal failure or conditions<br />

Better light quality<br />

• Optimizes lamp color stability over life<br />

• Reduces lamp-to-lamp color variations<br />

both initially and during lamp life<br />

• Provides enhanced capability for high ambient<br />

temperatures by transferring heat away from<br />

sensitive internal components<br />

1.0 Ballast Factor<br />

e-Vision <strong>Electronic</strong> Ballast Catalog Number Explanation<br />

I ZT – MH – _ 100 – A – BLS<br />

• Lamp produces maximum light output over it’s<br />

entire life.<br />

ELECTRONIC HID<br />

e-Vision ®<br />

Lead Exit / Mounting Options:<br />

BLS = Bottom Leads with Studs<br />

LF = Leads (side exit) with mounting Feet<br />

LFS = Leads (side exit, lead exit from same end) with mounting Feet (RMH-39-K Only)<br />

Can Material / Size: (Dimensions include mounting feet)<br />

A = Metal case with dim. 5.5” L x 3.6” W x 1.5” H<br />

C = Metal case with dim. 8.0” L x 3.6” W x 1.5” H<br />

D = Metal case with dim. 5.0” L x 3.0” W x 1.5” H<br />

E = Metal case with dim. 5.5” L x 1.75” W x 1.2” H<br />

G = Metal case with dim. 3.9” L x 3.0” W x 1.2” H<br />

H = Metal case with dim. 6.4” L x 3.7” W x 1.5” H<br />

J = Metal case with dim. 5.9” L x 1.8” W x 1.2” H<br />

K = Metal case with dim. 4.75” L x 1.3” W x 1.2” H<br />

Maximum Lamp Wattage<br />

20 = 22W Lamp (Philips MiniMaster Color Lamp) 39 = 39W Lamp 50 = 50W Lamp 70W = 70W Lamp<br />

100 = 100W Lamp 150 = 100W Lamp 175 = 175W Lamp 200W = 200W Lamp<br />

(Some ballasts are dual voltage - See product table)<br />

Number of Lamps: Blank = 1 Lamp Operations 2 = (2) Lamp Operation<br />

Primary Lamp Type:<br />

MH = Metal Halide<br />

WSN = Mini whiteSON (100W ONLY)<br />

SN = High Pressure Sodium<br />

Dimming Scheme: Blank = Fixed Light Output ZT = 0-10V Dimming<br />

Input Voltage:<br />

I = Intellivolt (accepts input of 120 thru 277V, 50/60 Hz nominal)<br />

R = 120V, 50/60 Hz nominal)<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 4-3


e-Vision® LOW FREQUENCY ELECTRONIC HID BALLASTS<br />

For Low Wattage HID Lamps<br />

e-Vision ® <strong>Electronic</strong> Ballast Specifications<br />

<strong>Section</strong> 1 - Physical Characteristics<br />

1.0 The electronic ballast shall be furnished with integral, colorcoded<br />

leads.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.0 The electronic ballast shall be IntelliVolt ® and operate from a<br />

nominal line voltage range of 120-277 volts, +/-10%, 50/60 Hz.<br />

2.1 The electronic ballast input current shall have Total Harmonic<br />

Distortion (THD) of less than 15%.<br />

2.2 The electronic ballast shall have a Power Factor greater than 90%.<br />

2.3 The electronic ballast shall have a lamp end-of-life detection<br />

and shutdown circuit.<br />

2.4 The electronic ballast shall be Sound Rated A.<br />

2.5 The electronic ballast output frequency to the lamps shall be<br />

less than 200 Hz to prevent acoustic resonance inside the lamp<br />

arc tube and to minimize visible flicker.<br />

2.6 The electronic ballast shall provide a “Lamp Current Crest<br />

Factor” of less than 1.5.<br />

2.7 The electronic ballast shall be thermally protected to shut off<br />

when operating temperatures reach unacceptable levels.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.0 The electronic ballast shall meet the requirements of the Federal<br />

Communications Commission rules and regulations, Title 47 CFR<br />

part 18, for Non-Consumer equipment.<br />

3.1 The electronic ballast shall be Underwriters Laboratories (UL)<br />

Listed and CSA Certified where applicable.<br />

<strong>Section</strong> IV - Other<br />

4.0 The electronic ballast shall not contain Polychlorinated Biphenyl<br />

(PCB’s).<br />

4.1 The electronic ballast shall carry a three-year warranty from the<br />

date of manufacture for operation at marked maximum case<br />

temperature or less.<br />

4.2 The manufacturer shall have a twenty-five year history of producing<br />

HID lamp ballasts for the North American market.<br />

4.3 The electronic ballast shall be produced in a factory certified to<br />

ISO 9002 Quality System Standards<br />

Installation Notes<br />

1. Red lead must be connected to center terminal of lamp (for Edison. screw base lamps). Do not connect red or blue lead to neutral or ground.<br />

2. Use 4.0 kV pulse rated lampholder. (Except where special lampholder is required, such as 22W Philips Mini MasterColor Lamp).<br />

3. Maximum ballast-to-lamp distance is 5 ft. using typical wiring methods and materials. Additional distance up to 15 ft. may be possible using<br />

wire between lamp and ballast with a total measured capacitance of 100 picofarads or less. Consult <strong>Advance</strong> for application assistance.<br />

4. Power mains must be cycled off and then on to reset ballast after failed lamps are replaced.<br />

ELECTRONIC HID<br />

e-Vision ®<br />

Ballast Hot Spot Location<br />

Hot spot locations differ with each ballast model and are designated on the individual ballast labels. Consult ballast labels and ballast<br />

specification sheets for Hot Spot locations.<br />

Enclosure Dimensions, Lead Lengths and Wiring Diagrams<br />

Fig 1 Fig 2 Fig 3<br />

(Red)<br />

(Red)<br />

(Blue)<br />

Lamp<br />

(Blue)<br />

Lamp<br />

Ballast<br />

(White/Black)<br />

Ballast<br />

(White)<br />

Com<br />

(White)<br />

(Black)<br />

120V - 277V<br />

(Black)<br />

(Green)<br />

120V - 277V<br />

Com<br />

Ballast Case must<br />

be Grounded<br />

Ballast Case must<br />

be Grounded<br />

Fig 4<br />

(Red)<br />

kV<br />

Lamp<br />

Fig 5<br />

(Red)<br />

kV<br />

Lamp 1<br />

kV<br />

Fig 6<br />

(Blue)<br />

(Red)<br />

Lamp<br />

Ballast<br />

(Black)<br />

(Blue)<br />

(White)<br />

120V<br />

Com<br />

Ballast<br />

(Blue)<br />

(Orange) Lamp 2<br />

(Brown)<br />

(White)<br />

Com<br />

(Black)<br />

120V - 277V<br />

Ballast<br />

(Violet) Dim +<br />

(Gray)<br />

Dim -<br />

(White)<br />

Com<br />

(Black)<br />

120V - 277V<br />

(Green)<br />

Ballast Case must<br />

be Grounded<br />

Ballast Case must<br />

be Grounded<br />

Ballast Case must<br />

be Grounded<br />

4-4<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


e-Vision® LOW FREQUENCY ELECTRONIC HID BALLASTS<br />

For Low Wattage HID Lamps<br />

Metal Halide and High Pressure Sodium<br />

Lamp Data<br />

Number<br />

Watts<br />

Input<br />

Volts<br />

Catalog Number*<br />

Note 1<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max.<br />

Case<br />

Temp.<br />

Note 6<br />

Wiring<br />

Diag.<br />

Fig.<br />

Weight<br />

(lb)<br />

Max.<br />

Distance to<br />

Lamp (ft)<br />

New<br />

New<br />

New<br />

New<br />

New<br />

New<br />

New<br />

New<br />

22 Watt Lamp, Philips Mini MasterColor, ANSI Code M175, Minimum Starting Temp. -20°C/-4°F<br />

1 22 120<br />

RMH-20-E-LF<br />

✓ ✓ 0.23 26 70°C 4 E 0.4<br />

RMH-20-E-BLS<br />

39 Watt Lamp, ANSI Code M130, Minimum Starting Temp. -30°C/-20°F<br />

RMH-39-K-LF or<br />

1 39 120 RMH-39-K-LFS<br />

✓ ✓ 0.40 45 90°C 4 K 0.5 6<br />

Note 2<br />

1 39<br />

120 IMH-39-G-LF or<br />

✓ ✓ 0.39 46<br />

277 IMG-39-G-BLS<br />

✓ ✓ 0.18 45<br />

90°C 3 G 0.9 5<br />

1 39<br />

120<br />

✓ ✓ 0.39 46<br />

277<br />

IMH-39-J-LF<br />

✓ ✓ 0.18 45<br />

90°C 3 J 0.9 5<br />

1 39<br />

120<br />

IMH-50-A-LF or<br />

✓ ✓ 0.38 45<br />

277<br />

IMH-50-A-BLS<br />

Note 3<br />

✓ ✓ 0.16 44<br />

85°C 1 A 1.4 5<br />

2 39<br />

120 IMH-239-A-LF or<br />

✓ ✓ 0.74 89<br />

277 IMG-239-A-BLS<br />

✓ ✓ 0.31 89<br />

85°C 5 A 1.7 6<br />

50 Watt Lamp, ANSI Code M110, Minimum Starting Temp. -30°C/-20°F<br />

1 50<br />

120<br />

IMH-50-A-LF or<br />

✓ ✓ 0.47 56<br />

277<br />

IMH-50-A-BLS<br />

Note 3<br />

✓ ✓ 0.20 55<br />

85°C 2<br />

70 Watt Lamp, ANSI Code M98 or M143 or M139, Minimum Starting Temp. -30°C/-20°F<br />

1 70<br />

120 IMH-70-G-LF or<br />

✓ ✓ 0.67 80<br />

277 IMG-70-G-BLS<br />

✓ ✓ 0.30 79<br />

90°C 3<br />

1 70<br />

120<br />

✓ ✓ 0.67 80<br />

277<br />

IMH-70-J-LF<br />

✓ ✓ 0.30 79<br />

90°C 3<br />

1 70<br />

120 IMH-70-D-LF or<br />

✓ ✓ 0.67 80<br />

277 IMH-70-D-BLS<br />

✓ ✓ 0.29 79<br />

85°C 3<br />

1 70<br />

120<br />

IMH-100-A-LF or<br />

✓ ✓ 0.68 82<br />

277<br />

IMG-100-A-BLS<br />

Note 4<br />

✓ ✓ 0.30 81<br />

85°C 1<br />

6<br />

A 1.4 5<br />

G 0.9 5<br />

J 0.9 5<br />

D 1.6 5<br />

A 1.4 5<br />

ELECTRONIC HID<br />

e-Vision ®<br />

Notes:<br />

1. All ballasts are sound rated A, and feature high power factor (>0.9, a ballast factor of 1.0 resettable thermal protection, and a maximum Harmonic Distortion of 15%.<br />

2. For RMH-39-K-LF, input and output lead wires exit on opposite sides of ballast. For RMH-39-K-LFS, all lead wires exit the same side of the ballast.<br />

3. A dual-wattage ballast for 39W or 50W MH<br />

4. A dual-wattage ballast for 70W or 100W MH<br />

5. A dual-wattage ballast for 150W or 175W MH<br />

6. Maximum case temperature should not be exceeded in the application, as life will be affected and the integral re-settable thermal protector may activate. A lower<br />

maximum temperature rating does not imply lesser thermal performance, and can be indicative of a cooler running ballast design. Consult factory for further<br />

application assistance.<br />

7. Also operates (1) 150W HPS S56 (100V) Lamp<br />

* Ordering information:<br />

–LF Side exit leads with mounting feet<br />

–BLS Bottom exit leads with mounting studs<br />

For ballast diagrams see page 4-7<br />

Wire Color<br />

Function Lengths Lead Lengths Length Strip<br />

(-LF model) (-BLS model)<br />

Black Input Power 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

White Input Power 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Black/White Lamp Power Selection (IMH models only) 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Red Lamp Base 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Blue Lamp Screwshell 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Green Ground 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Orange Lamp Base 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Brown Lamp Screwshell 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 4-5


e-Vision LOW FREQUENCY ELECTRONIC HID BALLASTS<br />

For Low Wattage Metal Halide Lamps<br />

Metal Halide and High Pressure Sodium<br />

Lamp Data<br />

Number<br />

Watts<br />

Input<br />

Volts<br />

Catalog Number*<br />

Note 1<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max.<br />

Case<br />

Temp.<br />

Note 6<br />

Wiring<br />

Diag.<br />

Fig.<br />

Weight<br />

(lb)<br />

Max.<br />

Distance to<br />

Lamp (ft)<br />

New<br />

New<br />

100 Watt Lamp, ANSI Code M90 or M140, Minimum Starting Temp. -30°C/-20°F<br />

1 100<br />

120 IMH-100-D-LF or<br />

✓ ✓ 0.92 110<br />

277 IMG-100-D-BLS<br />

✓ ✓ 0.40 109<br />

85°C 3 D 1.6 5<br />

1 100<br />

120<br />

IMH-100-A-LF or<br />

✓ ✓ 0.93 112<br />

277<br />

IMH-100-A-BLS<br />

Note 4<br />

✓ ✓ 0.40 110<br />

85°C 2 A 1.4 5<br />

150 Watt Lamp, ANSI Code M102 or M142, Minimum Starting Temp. -30°C/-20°F<br />

1 150<br />

120 IMH-150-H-LF or<br />

✓ ✓ 1.4 165<br />

277 IMG-150-H-BLS<br />

✓ ✓ 0.6 161<br />

85°C 3 H 1.9 5<br />

1 150<br />

120<br />

IMH-175-C-LF or<br />

✓ ✓ 1.4 169<br />

277<br />

IMH-175-C-BLS<br />

Note 5,7 ✓ ✓ 0.6 166<br />

85°C 1 C 2.5 5<br />

175 Watt Pulse Start Lamp, ANSI Code M137 or M152 (Pulse Start), Minimum Starting Temp. -30°C/-20°F<br />

1 175<br />

120<br />

IMH-175-C-LF or<br />

✓ ✓ 1.7 194<br />

277<br />

IMH-175-C-BLS<br />

Note 5<br />

✓ ✓ 0.7 191<br />

85°C 2 C 2.5 5<br />

200 Watt Pulse Start Lamp, ANSI Code M136 (Pulse Start), Minimum Starting Temp. -30°C/-20°F<br />

1 200<br />

120<br />

2.0 229<br />

IMH-200-C-LF ✓ ✓<br />

277<br />

1.0 219<br />

85°C 3 C 2.5 5<br />

100 Watt Lamp, Philips Mini whiteSON (SDW-TG), ANSI Code S167 (Pulse Start), Min. Starting Temp. -20°C/-4°F<br />

120 IWSN-150-C-LF or<br />

✓ ✓ 0.9 165<br />

1 150<br />

85°C 3 C 1.9 5<br />

277 IWSN-150-C-BLS<br />

✓ ✓ 0.5 161<br />

ELECTRONIC HID<br />

e-VISION<br />

New<br />

New<br />

CONTROLLABLE BALLASTS WITH 0-10V DIMMING INTERFACE Note 8<br />

Lamp Data<br />

Number<br />

Watts<br />

Input<br />

Volts<br />

Notes:<br />

1. All ballasts are sound rated A, and feature high power factor (>0.9, a ballast factor of 1.0 resettable thermal protection, and a maximum Harmonic Distortion of 15%.<br />

2. For RMH-39-K-LF, input and output lead wires exit on opposite sides of ballast. For RMH-39-K-LFS, all lead wires exit the same side of the ballast.<br />

3. A dual-wattage ballast for 39W or 50W MH<br />

4. A dual-wattage ballast for 70W or 100W MH<br />

5. A dual-wattage ballast for 150W or 175W MH<br />

6. Maximum case temperature should not be exceeded in the application, as life will be affected and the integral re-settable thermal protector may activate. A lower<br />

maximum temperature rating does not imply lesser thermal performance, and can be indicative of a cooler running ballast design. Consult factory for further<br />

application assistance.<br />

7. Also operates (1) 150W HPS S56 (100V) Lamp<br />

* Ordering information:<br />

–LF Side exit leads with<br />

mounting feet<br />

–BLS Bottom exit leads with<br />

mounting studs<br />

Catalog Number*<br />

Note 1<br />

Certifications<br />

Line<br />

Current<br />

(Amps)<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Max.<br />

Case<br />

Temp.<br />

Note 6<br />

150 Watt Lamp, ANSI Code M102 or M142, Minimum Starting Temp. -30°C/-20°F<br />

120<br />

✓ ✓ 1.4 169<br />

1 150<br />

277<br />

IZTMH-150-C-LF<br />

85°C<br />

✓ ✓ 0.6 166<br />

150 Watt HPS Lamp, ANSI Code S56 (100V), Minimum Starting Temp. -30°C/-20°F<br />

120<br />

✓ ✓ 1.4 169<br />

1 150<br />

277<br />

IZTSN-150-C-LF<br />

85°C 6<br />

✓ ✓ 0.6 166<br />

Wiring<br />

Diag.<br />

For ballast diagrams see page 4-7<br />

Wire Color<br />

Function Lengths Lead Lengths Length Strip<br />

(-LF model) (-BLS model)<br />

Black Input Power 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

White Input Power 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Black/White Lamp Power Selection (IMH models only) 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Red Lamp Base 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Blue Lamp Screwshell 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Green Ground 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Orange Lamp Base 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

Brown Lamp Screwshell 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />

6<br />

Fig.<br />

Weight<br />

(lb)<br />

Max.<br />

Distance to<br />

Lamp (ft)<br />

C 2.5 5<br />

C 2.5 5<br />

4-6<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


e-Vision LOW FREQUENCY ELECTRONIC HID BALLASTS<br />

For Low Wattage Metal Halide Lamps<br />

Case<br />

Figure<br />

Overall<br />

Length<br />

Case<br />

Length<br />

Case<br />

Width<br />

Height Mounting<br />

Length<br />

Mounting<br />

Width<br />

A<br />

140mm<br />

[5.5"]<br />

120mm<br />

[4.7"]<br />

92mm<br />

[3.6"]<br />

38mm<br />

[1.5"]<br />

132mm<br />

[5.2"]<br />

73mm<br />

[2.9"]<br />

C<br />

204mm<br />

[8.0"]<br />

184mm<br />

[7.2"]<br />

92mm<br />

[3.6"]<br />

38mm<br />

[1.5"]<br />

195mm<br />

[7.7"]<br />

73mm<br />

[2.9"]<br />

H<br />

161mm<br />

[6.3"]<br />

144mm<br />

[5.7"]<br />

92mm<br />

[3.6"]<br />

38mm<br />

[1.5"]<br />

152mm<br />

[6.0"]<br />

73mm<br />

[2.9"]<br />

Case<br />

Figure<br />

Overall<br />

Length<br />

Case<br />

Length<br />

Case<br />

Width<br />

Height<br />

Mounting Mounting<br />

Length Width<br />

D<br />

128mm<br />

[5.0"]<br />

108mm<br />

[4.3"]<br />

77mm<br />

[3.0"]<br />

38mm<br />

[1.5"]<br />

118mm<br />

[4.6"]<br />

19mm<br />

[0.7"]<br />

Case<br />

Figure<br />

Overall<br />

Length<br />

Case<br />

Length<br />

Case<br />

Width<br />

Height<br />

Mounting Mounting<br />

Length Width<br />

E<br />

140mm<br />

[5.5"]<br />

127mm<br />

[5.0"]<br />

44mm<br />

[1.7"]<br />

30mm<br />

[1.2"]<br />

135mm<br />

[5.3"]<br />

26mm<br />

[1.0"]<br />

J<br />

149mm<br />

[5.9"]<br />

140mm<br />

[5.5"]<br />

46mm<br />

[1.8"]<br />

30mm<br />

[1.2"]<br />

145mm<br />

[5.7"]<br />

27mm<br />

[1.0"]<br />

ELECTRONIC HID<br />

e-VISION<br />

Case<br />

Figure<br />

Overall<br />

Length<br />

Case<br />

Length<br />

Case<br />

Width<br />

Height<br />

Mounting Mounting<br />

Length Width<br />

G<br />

97mm<br />

[3.8"]<br />

90mm<br />

[3.5"]<br />

77mm<br />

[3.0"]<br />

30mm<br />

[1.2"]<br />

87mm<br />

[3.4"]<br />

67mm<br />

[2.6"]<br />

Case<br />

Figure<br />

Overall<br />

Length<br />

Case<br />

Length<br />

Case<br />

Width<br />

Height<br />

Mounting Mounting<br />

Length Width<br />

K<br />

113mm<br />

[4.4"]<br />

104mm<br />

[4.1"]<br />

33mm<br />

[1.1"]<br />

30mm<br />

[1.2"]<br />

13.5mm<br />

[0.5"]<br />

114mm<br />

[4.5"]<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 4-7


DYNAVISION ELECTRONIC HID BALLASTS<br />

DynaVision extends the key benefits<br />

of magnetic pulse-start metal halide<br />

systems — energy efficiency and<br />

white light. With its very-high<br />

frequency operation, as well as<br />

its on-board microprocessor and<br />

standard features, DynaVision<br />

provides numerous additional<br />

benefits and advantages.<br />

DynaVision Features<br />

Microprocessor technology<br />

High frequency operation<br />

True constant wattage<br />

320/350/400 Tri-Wattage<br />

IntelliVolt 200-277V 50/60 Hz<br />

Integral 120V quartz tap<br />

and relay, 250W<br />

0-10V dimming with automatic<br />

15-minute warm up<br />

Benefits and Advantages<br />

Lower operating and maintenance costs<br />

Fewer fixtures<br />

Energy savings<br />

Fewer SKU’s<br />

Less chance for error<br />

Ease of change over<br />

to different wattage lamps<br />

Standby-lighting ready<br />

No special orders<br />

No special relay or control required<br />

Continuous dimming down to 50% power<br />

Additional energy savings through<br />

daylight harvesting and occupancy sensing<br />

0º to 55ºC ambient rating standard Greater reliability, flexibility and<br />

-40º to +40ºC ambient rating optional and applications opportunities<br />

Lamp End-of-Life Protection (EOL)<br />

Safety<br />

ELECTRONIC HID<br />

DYNAVISION<br />

Physical Characteristics<br />

2.3˝<br />

Optional<br />

junction box<br />

4.0˝<br />

Fully closed<br />

extruded aluminum<br />

housing with white finish<br />

3.7˝<br />

8.8˝ mounting<br />

dimensions<br />

DIP switch access<br />

for lamp wattage selection<br />

More about...<br />

Standby Lighting Versatility<br />

DynaVision’s 120-volt output is designed<br />

to operate one quartz (incandescent)<br />

standby lamp up to 250W. The quartz<br />

lamp on or off modes are determined by the<br />

HID lamp’s specific operating conditions.<br />

Once the HID lamp strikes, the quartz lamp<br />

automatically switches off when the HID<br />

lamp reaches 50% power.<br />

9.2˝ bracket end-to-end length<br />

8.0˝<br />

5.0˝<br />

Hot spot measurement<br />

location at screw<br />

4.4˝ mounting<br />

dimensions<br />

2.6˝<br />

Integral mounting brackets<br />

5mm mounting<br />

holes (4) for<br />

#10 screws<br />

Controllability<br />

DynaVision is dimmable – down to 50% of nominal lamp<br />

power, with no noticeable loss in color characteristics.<br />

With 0-10V dimming, and compatible with a host of<br />

products from most control manufacturers, DynaVision<br />

brings new flexibility and energy-saving strategies,<br />

such as daylight harvesting and occupancy sensing, to<br />

applications in the industrial, educational, government,<br />

hospitality, commercial and retail sectors.<br />

DynaVision <strong>Electronic</strong> Ballast<br />

Catalog Number Breakdown<br />

IZTEMH4003PS - XJ<br />

Basic Model Number<br />

Options<br />

I = IntelliVolt (200-277 50/60 Hz)<br />

ZT = Zero-to-ten volt dimming<br />

E = <strong>Electronic</strong><br />

MH = Metal Halide<br />

400 = 400W maximum<br />

3 = 3 wattage capability (320/350/400W)<br />

PS = Pulse-Start<br />

-XJ = Without junction box<br />

(i.e. junction box is included if this suffix is omitted).<br />

F = Low temperature version (-40ºC to+55ºC)<br />

4-8<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


DYNAVISION ELECTRONIC HID BALLASTS<br />

DynaVision <strong>Electronic</strong> Ballast Specifications<br />

<strong>Section</strong> I – Physical Characteristics<br />

1.1 The electronic ballast shall be fully enclosed in an aluminum<br />

housing painted white.<br />

1.2 The aluminum housing shall include a divided wiring compartment<br />

to separate the power leads from the control leads. All leads to be<br />

color-coded.<br />

2.8 The electronic ballast shall be Sound Rated A.<br />

2.9 The electronic ballast output frequency to the lamps shall be<br />

higher than 100 kHz to prevent acoustic resonance inside the<br />

lamp arc tube and to minimize visible flicker.<br />

2.10 The electronic ballast shall be thermally protected to shut off<br />

when operating temperatures reach unacceptable levels.<br />

<strong>Section</strong> II – Performance Requirements<br />

2.1 The electronic ballast shall be multivoltage capable and operate<br />

from a line voltage range of 180 – 305 volts, 50/60 Hz.<br />

2.2 The electronic ballast shall incorporate a microprocessor controller<br />

to provide for optimum starting and operation of the HID lamp.<br />

2.3 The electronic ballast input current shall have Total Harmonic<br />

Distortion (THD) of less than 15% when operated at nominal line<br />

voltage (200V, 208V, 230V, 240V, 277V).<br />

2.4 The ballast shall incorporate a 0-10V dimming interface and<br />

control the dimming function such that the HID lamp is allowed<br />

to warm up for fifteen minutes at full power before the lamp will<br />

be allowed to dim, regardless of the level of the 0-10V signal.<br />

10V applied to the dimming control leads, shall result in full<br />

light output. 0V applied, or shorting the control leads together,<br />

shall result in dimming to 50% of nominal lamp power.<br />

2.5 The ballast shall include a 120V/250W auxiliary output for stand-by<br />

incandescent lighting that shall include an integral control to turn<br />

the auxiliary lamp on and off. The integral control shall include a<br />

time-delay feature to keep the auxiliary lamp on until the HID<br />

lamp reaches 50% power.<br />

2.6 The electronic ballast shall have a Power Factor greater than 90%.<br />

2.7 The electronic ballast shall have a lamp end-of-life detection and<br />

shutdown circuit.<br />

<strong>Section</strong> III – Regulatory Requirements<br />

3.1 The electronic ballast shall meet the requirements of the Federal<br />

Communications Commission rules and regulations, Title 47 CFR<br />

part 18, for Non-Consumer equipment.<br />

3.2 The electronic ballast shall be Underwriters Laboratories (UL)<br />

Listed and CSA Certified where applicable.<br />

<strong>Section</strong> VI – Other<br />

4.1 The electronic ballast shall not contain Polychlorinated Biphenyl<br />

(PCB’s).<br />

4.2 The electronic ballast shall carry a three-year warranty from the<br />

date of manufacture for operation at an ambient temperature of<br />

55° C or less and when operated as a stand alone product<br />

(i.e.remotely from a lighting fixture housing). When operated<br />

within a lighting fixture housing, the same three-year warranty<br />

shall apply for a maximum ballast case hot spot temperature of<br />

76° C or less.<br />

4.3 The manufacturer shall have a twenty-five year history of producing<br />

HID lamp ballasts for the North American market.<br />

4.4 The electronic ballast shall be produced in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

ELECTRONIC HID<br />

DYNAVISION<br />

Installation and Application Notes<br />

1. Red lead must be connected to center terminal of lamp.<br />

Do not connect red or blue lead to line neutral.<br />

2. Setting precaution with triple-wattage feature: Do not operate<br />

lower wattage lamp on a ballast which has been set for operation<br />

of higher wattage lamp. Short lamp life may result.<br />

3. Ballast output will shut off after 40 minutes maximum if lamp<br />

does not successfully ignite. Replace lamp and cycle mains to<br />

restore output.<br />

4. Use 4.0 kV pulse rated lampholder.<br />

5. Connect red lamp lead to 600Vrms, 3.5kV or UL style 1452 wire.<br />

6. Remote mounting distances not exceeding 15 ft. are possible with<br />

normal wiring methods. For distances greater than 15 ft., power<br />

losses in the wire can result in appreciable decline in actual lamp<br />

operating power. Consult <strong>Advance</strong> for application assistance.<br />

7. Mains must be cycled after replacing lamp.<br />

8. Ballast output exceeds 100kHz. Suitable test equipment is required<br />

for measurement.<br />

9. Ballast is suitable for recessed use. Do not install insulation above or<br />

within 3” of ballast sides.<br />

Where to Measure the Ballast Hot Spot<br />

Hot spot at forward screw location<br />

Side View<br />

Optional<br />

junction box<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 4-9


DYNAVISION ELECTRONIC HID BALLASTS<br />

Breaks New Ground in HID Performance<br />

Pulse-Start Metal Halide<br />

Min Input Max. Min. DIP<br />

Lamp Data Start Input Catalog Listings Line Power Ballast THD PF Switch<br />

Temp. Volts Number Current ANSI Factor % % Settings<br />

No. Watts (F/C) (A) (W)<br />

320 Watt Lamp, ANSI Code M132/M154<br />

Application Specifications<br />

New<br />

New<br />

New<br />

1 320 32/0 200 to IZTEMH4003PS 1.8 @ 200V 345 1.0 15 90<br />

-40/-40 277 IZTEMH4003PS-F 1.3 @ 277V<br />

350 Watt Lamp, ANSI Code M131<br />

1 350 32/0 200 to IZTEMH4003PS 1.9 @ 200V 375 1.0 15 90<br />

-40/-40 277 IZTEM4003PS-F 1.4 @ 277V<br />

400 Watt Lamp, ANSI Code M135/M155<br />

1 400 32/0 200 to IZTEMH4003PS 2.2 @ 200V 430 1.0 15 90<br />

-40/-40 277 IZTEM400EPS-F 1.6 @ 277V<br />

NOTE: These specifications apply to operation of pulse-start metal halide lamps with quartz arc-tube construction only.<br />

For operating compatibility with ceramic arc-tube lamps, consult <strong>Advance</strong>.<br />

Preset at Factory<br />

DIP switches are “on”<br />

in the down position<br />

ON<br />

ON<br />

ON<br />

ELECTRONIC HID<br />

DYNAVISION<br />

Dimming Feature<br />

With an integral, industry-standard 0-10V interface, the<br />

DynaVision electronic ballasts offer the capability to dim<br />

the lamp by lowering the wattage lamp, reducing energy<br />

consumption of the light fixture by up to 50%. Access to<br />

this interface is via the violet (+) and grey (-) dimming<br />

control leads. These leads can be connected to either a<br />

0-10V dimming control, (DynaVision ballast are compatible<br />

with standard 0-10V control devices available from many<br />

manufacturers) a 0-10V DC power supply, or with a switch.<br />

An open switch provides full lamp power, and a closed<br />

switch, short-circuiting the 0-10V wires, yields 50% lamp<br />

power. Control devices such as relays and occupancy sensors<br />

may also be used.<br />

A potentiometer may also be used. However, the value of<br />

the potentiometer is dependent on the number of ballasts<br />

connected. Consult <strong>Advance</strong> for guidance.<br />

In accordance with the requirements of the HID<br />

lamp manufacturers and NEMA, the dimming feature<br />

includes a time delay to allow the HID lamp to<br />

warm up for 15 minutes at full power before the<br />

lamps will be allowed to dim, regardless of the level<br />

of the 0-10V signal.<br />

Lead Wire Information<br />

Wire Color Function<br />

Black Input Power<br />

White Input Power<br />

Green Ground<br />

Red Lamp Eyelet<br />

Blue Lamp Screwshell<br />

Yellow (2) 120V Lamp Output<br />

Violet 0-10V Dimming (+)<br />

Grey 0-10V Dimming (-)<br />

All lead lengths<br />

are 11" +/- 1".<br />

The black & white<br />

(input power), green<br />

(ground), and red &<br />

blue (lamp) leads are<br />

pre-stripped 1/2".<br />

The two yellow 120v<br />

(output) and violet<br />

& grey (dimming<br />

control) leads have<br />

insulated ends.<br />

4-10<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

HID<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Contents<br />

General Information .................................................................5-2 to 5-3<br />

Core & Coil Ballast HID Replacement Kits..............................5-4 to 5-7<br />

EEI-NEMA Head <strong>Ballasts</strong>.....................................................................5-8<br />

Core & Coil Ballast HID Replacement Kits (Canada) ........................5-9<br />

Val-U-Pak Replacement Kits ............................................................5-10<br />

Val-U-Pak Plus Ballast/Lamp Replacement Kits .............................5-11<br />

Core & Coil <strong>Ballasts</strong> 71A Series (60 Hz)<br />

Mercury..........................................................................5-14 to 5-17<br />

Metal Halide ...................................................................5-18 to 5-31<br />

High Pressure Sodium ...................................................5-32 to 5-45<br />

Low Pressure Sodium....................................................5-46 to 5-47<br />

Capacitors for Bi-Level Operation ....................................................5-48<br />

Non-PCB Capacitors ............................................................5-48 to 5-49<br />

Ignitors & Ballast to Lamp Distances..................................5-50 to 5-53<br />

Transformers & Autotransformers ....................................................5-54<br />

Protected Dual-Volt F-Can 72C Series.................................5-55 to 5-58<br />

Mercury — Metal Halide — High Pressure Sodium<br />

Encapsulated Core & Coil 73B Series .................................5-59 to 5-62<br />

Mercury — Metal Halide — High Pressure Sodium<br />

Postline <strong>Ballasts</strong> 74P Series................................................5-63 to 5-66<br />

Mercury — Metal Halide — High Pressure Sodium<br />

Indoor Enclosed <strong>Ballasts</strong> 78E Series...................................5-67 to 5-68<br />

Mercury — Metal Halide — High Pressure Sodium<br />

Outdoor Weatherproof <strong>Ballasts</strong> 79W Series.......................5-69 to 5-71<br />

Mercury — Metal Halide — High Pressure Sodium<br />

Note:<br />

For International HID <strong>Ballasts</strong> (50Hz and 60Hz),<br />

See International <strong>Section</strong>, pages 6-14 to 6-19<br />

For <strong>Electronic</strong> HID <strong>Ballasts</strong>, See <strong>Section</strong> 4<br />

HID<br />

Corporate Offices<br />

(800) 322-2086<br />

Customer Support/Technical Service<br />

(800) 372-3331 • (+) 1 847 390-5000 (International)<br />

Visit our web site at www.advancetransformer.com<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-1


HIGH INTENSITY DISCHARGE BALLASTS<br />

ADVANCE ® HID Lamp <strong>Ballasts</strong> are available to operate the wide variety<br />

of mercury, metal halide, high pressure sodium and low pressure<br />

sodium lamps available in today’s marketplace.<br />

Like fluorescent, HID lamps are electric discharge lamps. Light is<br />

produced by an arc discharge between two electrodes located at<br />

opposite ends of an arc tube within the lamp’s outer glass envelope.<br />

The ballast is the lamp’s power supply; its purpose is to provide<br />

proper starting and operating voltage and current to initiate and sustain<br />

this arc.<br />

LAMP STARTING<br />

Mercury and Probe-Start Metal Halide Lamps<br />

Mercury and the “traditional” probe-start metal halide lamps (175<br />

through 1500 watt) have an additional electrode located at one end<br />

of the arc tube to assist in lamp starting. These types of lamps<br />

require an open circuit voltage (OCV) approximately two times the<br />

lamp’s operating voltage to initiate the arc.<br />

High Pressure Sodium and Pulse-Start Metal Halide Lamps<br />

High pressure sodium and modern metal halide lamps which include<br />

existing lamps, 150 watt and less, as well as the new generation of<br />

pulse-start metal halide lamps, 150 watt and greater, have no starting<br />

electrodes. In addition to an OCV of approximately two times the lamp<br />

voltage, these lamps utilize an “ignitor” to provide a high voltage<br />

starting pulse directly across the main electrodes. Once the lamp’s arc<br />

is established, the ignitor automatically stops delivering pulses, and<br />

the lamp comes up to full brightness on its own.<br />

Low Pressure Sodium<br />

Because they have neither a starting electrode nor an ignitor, low pressure<br />

sodium lamps require an open circuit voltage approximately three<br />

to seven times the lamp voltage to start and sustain the lamp.<br />

4-tap design is called a Quadri-Volt ® ballast and operates on either 120V,<br />

208V, 240V or 277V power. There is an <strong>Advance</strong> Quadri-Volt ® ballast for<br />

virtually every HID lamp on the market. New 5-TAP designs, which<br />

feature the same input voltages as Quadri-Volt ® ballasts plus 480V,<br />

are available for 250W, 400W, and 1000W metal halide and high<br />

pressure sodium applications.<br />

FIXTURE FUSING<br />

Many HID lighting fixtures are sold with protective fuses. The purpose<br />

of the fuse is to isolate a fixture from the lighting circuit in the event<br />

of excessive current draw, such as might be caused by a failed ballast.<br />

Unfortunately, the fuse will not protect the ballast from failure, as<br />

it is often the failed ballast itself that is causing the high current draw.<br />

With many fixtures the fuse is physically located in the ballast<br />

compartment of the fixture. The air temperature within this compartment<br />

can easily reach 80°C and still be within the design limitations<br />

of the fixture.<br />

Many fuses are temperature sensitive, meaning that the current rating<br />

goes down as the ambient temperature goes up. Fuse current ratings<br />

are based on the fuse’s performance in a 25°C ambient (77°F). In<br />

an 80°C ambient, some fuses will open at half their rating.<br />

As a result, the fuse rating shown in the HID ballast tables is calculated<br />

at 2 1 /2 to 3 times the highest current draw of the ballast: lamp operating,<br />

starting or open circuit conditions. Standard or slow-blow fuses<br />

should be used. Fast-blow fuses should be avoided as ballast in-rush<br />

currents during power turn-on could cause these fuses to blow<br />

unnecessarily. It is not necessary to use current limiting fuses.<br />

BALLAST DESIGN APPLICATIONS<br />

HID lamp ballasts are available in a variety of shapes and sizes for<br />

the most popular lighting applications. Six basic designs are in<br />

widest use today.<br />

HID<br />

LAMP OPERATION<br />

<strong>Electric</strong> discharge lamps have a negative resistance characteristic<br />

which causes them to draw an increasing amount of current leading<br />

to immediate destruction if operated directly from the power line.<br />

The ballast, therefore, is utilized to limit the current to the correct<br />

level for proper operation of the lamp.<br />

Ballast factor is defined as the ratio of light output produced by a<br />

lamp operating on a commercial ballast versus the lamp’s rated light<br />

output. <strong>Advance</strong> HID ballasts have a nominal ballast factor of 1.0,<br />

thus providing full light output.<br />

HID lamps take several minutes to warm-up and reach full lumen<br />

output. Additionally, an interruption in the input power or a sudden<br />

voltage drop may cause the arc to extinguish. A lamp that is hot will<br />

not restart immediately. Before the lamp will relight, it must cool sufficiently<br />

to reduce the vapor pressure within the arc tube to a point<br />

where the arc will restrike. The approximate warmup and restriking<br />

times of the HID lamp groups are as follows:<br />

LIGHT SOURCE WARM-UP TIME RESTRIKE TIME<br />

Mercury Vapor 5-7 minutes 3-6 minutes<br />

Metal Halide (Probe-Start) 3-4 minutes 10-20 minutes<br />

Metal Halide (Pulse-Start) 2 minutes 3-4 minutes<br />

High Pressure Sodium 3-4 minutes 1/2-1 minute<br />

Low Pressure Sodium 7-10 minutes 3-12 seconds<br />

BALLAST INPUT VOLTAGES<br />

Unlike fluorescent lighting which is operated on either 120 volt or<br />

277 volt circuits, power for HID lighting in the U.S. is delivered at any<br />

one of five voltages: 120V, 208V, 240V, 277V or 480V. While 120V<br />

and 277V are the most popular, because of the heavier loads and<br />

sometimes longer runs associated with HID lighting (such as shopping<br />

mall parking lots), 208V and 240V power is often used instead<br />

of 120V, and 480V instead of 277V.<br />

To address this multiplicity of voltages, the HID ballast industry offers<br />

ballasts with multiple input voltage taps on the primary coil. <strong>Advance</strong>'s<br />

Fluorescent Can<br />

(72C Series)<br />

Indoor Enclosed<br />

Rectangular Can<br />

(78E Series)<br />

Encapsulated Core & Coil<br />

(73B Series)<br />

Core & Coil<br />

The basic ballast is the open core & coil which is most often used as<br />

a component within a lighting fixture. The core & coil also forms the<br />

nucleus of the five other ballast configurations detailed in this section.<br />

It consists of either one, two or three copper coils on a core (or “stack”)<br />

of electrical-grade steel laminations. The coils are assembled to core<br />

sections which are then surface-welded together. At <strong>Advance</strong><br />

Transformer Co. the assembled ballast is vacuum impregnated with a<br />

silica-filled polyester varnish to re-enforce the electrical insulation, preclude<br />

moisture, inhibit noise, and dissipate heat. <strong>Advance</strong> utilizes a<br />

vacuum-pressure impregnation process. Most other HID ballast manufacturers<br />

apply varnish via a preheat-and-dip process which only puts a<br />

thin coat of varnish on the outer surface of the ballast. <strong>Advance</strong> Core &<br />

Coil ballasts feature as standard an insulation system rated class H<br />

(180°C maximum coil hot spot temp.) for ballasts below 600 watts, and<br />

ADVANCE Class N (200°C maximum coil hot spot temp.) for ballasts<br />

600 watts and higher. When performing in-fixture testing, the maximum<br />

allowable average coil temperature (measured by the rise-of-resistance<br />

method) is 165°C for class H ballasts or 185°C for ADVANCE Class N<br />

ballasts. The maximum allowable coil face or lead wire temperature<br />

(measured by thermocouple) is 150°C for both class H and ADVANCE<br />

Class N ballasts.<br />

5-2<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Encapsulated Core & Coil<br />

Where quiet performance is required, the standard open core & coil ballasts<br />

are encapsulated (potted) in a cube-shaped steel can utilizing<br />

Class H (180°C) polyester compound. These ballasts carry a Class A<br />

noise rating up through 175 watts and Class B for 250 and 400 watts.<br />

As with the open core & coil, the capacitor (and ignitor where included)<br />

are mounted separately within the fixture.<br />

<strong>Ballasts</strong> with Aluminum Secondary Coil<br />

<strong>Advance</strong> offers a wide range of ballasts that have primary coil made out<br />

of copper and secondary coil made out of aluminum. All <strong>Advance</strong> ballasts<br />

including ballasts with aluminum secondary coil adhere to ANSI<br />

specifications and are certified by respective agencies (UL, CSA, etc.).<br />

Aluminum ballasts are designated by -A after ballast Catalog number<br />

and/or “AL” on wiring diagram.<br />

Fluorescent Can (F-Can)<br />

For indoor commercial applications of HID lighting such as offices,<br />

schools and retail stores, ballast noise must be minimized. <strong>Ballasts</strong> for<br />

these fixtures are most often encased and potted in fluorescent ballast<br />

type cans and utilize Class A (90°C) asphalt insulating materials (the<br />

same as used in fluorescent lamp ballasts).<br />

The <strong>Advance</strong> line of F-can ballasts comes in two dual-voltage configurations:<br />

120/277 volt for the US market, and 120/347 volt for the<br />

Canadian market. Each unit has built-in, automatically resetting, thermal<br />

protectors which disconnect the ballast from the power line in the<br />

event of overheating. All units are high power factor and include the<br />

capacitor within the can. All models for high pressure sodium, lowwattage<br />

metal halide, and pulse-start metal halide lamps also include<br />

the ignitor in the can.<br />

Spacing between ballasts and the mounting surface must be considered<br />

when the ballasts are remote-mounted. Twelve inches between<br />

ballasts must be maintained and if multiple rows vertically are used,<br />

there should be at least 12 inches between rows. In addition to ballast<br />

and row spacing, the ballast must not be directly mounted to a nonmetallic<br />

surface. They must be spaced with mounting brackets (available<br />

from <strong>Advance</strong>) to allow airflow under the ballast base.<br />

Indoor Enclosed<br />

These units are designed for use indoors where the ballast must be<br />

mounted remotely from the luminaire. They are most typically used in<br />

factories where the luminaire may be mounted in a high-bay where very<br />

high ambient temperatures may be experienced. In these instances, the<br />

remotely-mounted ballast operates cooler, subsequently providing<br />

longer life because it is away from both the heat of the ceiling ambient<br />

and lamp heat within the fixture.<br />

The case contains the core & coil potted in a Class H (180°C) heatdissipating<br />

resin. The capacitor(s) and ignitor are contained within a<br />

separate compartment. Knockouts in both ends of the case facilitate<br />

hook-up in the most convenient manner. Wall mounting is accomplished<br />

through flanges on the top and bottom of the case. The ballast<br />

is a UL Listed product.<br />

Outdoor Weatherproof<br />

Weatherproof ballasts are designed for remote, pole-mounting outdoor<br />

applications under all weather conditions. They may also be placed inside<br />

of a transformer pole base, but care must be taken to avoid areas prone<br />

to flooding because weatherproof ballasts are not water-submersible.<br />

The core & coil with its capacitor and ignitor (where required) are<br />

firmly mounted to the heat-sink base. An aluminum cover is placed over<br />

the core-&-coil assembly and is bolted with a weather-tight gasket to<br />

the base. An integral 1" threaded nipple with locknut facilities hook-up<br />

to electrical conduit or to the mounting bracket when used on a pole.<br />

The weatherproof ballast may also be placed nipple-up, with a drip loop<br />

in the leads, inside a pole base.<br />

Postline<br />

Lantern-type fixtures mounted on slender poles often require ballasts<br />

which will fit into these poles. Special, elongated core & coil ballasts are<br />

potted in resin in cylindrical cans having a 2.55” outside diameter. All<br />

include leads necessary for direct connection to a photocell.<br />

The capacitor and ignitor (where required) are included within this<br />

can. A ¹₂" threaded nipple is used for vertical mounting, and leads<br />

extend from both ends of the can for ease of installation. The input<br />

leads to the ballast also provide for proper connection to the photocell<br />

if such is included within the fixture.<br />

To help prevent overheating, one to three feet of air space should be<br />

allowed in the pole above the ballast, and the ballast should be positioned<br />

against the post interior wall to provide a heat-sink. All units<br />

rated 100W and above now include a mounting kit consisting of an 18"<br />

chain to hang the ballast within the pole and a spring clip to force the<br />

ballast's cylindrical can to make line contact with the pole's interior<br />

surface to maximize heat transfer, thus prolonging the ballast life.<br />

BALLAST DATE AND TEMPERATURE CODES<br />

Ballast Label<br />

Catalog Number<br />

Alternate Positions for<br />

Date Stamp Code<br />

Temperature<br />

Code<br />

Date Code<br />

Stamp<br />

ADVANCE ® HID Core & Coil ballasts are date stamped on either the top<br />

surface or the side surface of the ballast core. The four-digit number represents<br />

the week and year of manufacture. The first two numbers indicate<br />

the week and the last two indicate the year the ballast was manufactured.<br />

The example shows a ballast manufactured during the 36th<br />

week of 1989. The three letters are an <strong>Advance</strong> factory code.<br />

The ballast’s UL Bench Top Rise Temperature Code is shown on the label<br />

(see below).<br />

UL BENCH TOP RISE TEMPERATURE CODE<br />

To facilitate UL inspection, each ballast’s UL Bench Top Rise<br />

Temperature Code is shown on the <strong>Advance</strong> Core & Coil ballast label as<br />

1029X, where 1029 is the UL Standard for HID <strong>Ballasts</strong>, and the X is the<br />

temperature code: A, B, C, etc. If a fixture is UL listed for 1029C, then<br />

automatically, all ballasts with an A, B, or C temperature classification<br />

are acceptable for use within that same fixture.<br />

UL Bench Top Rise<br />

Letter Code<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

etc.<br />

Temperature Range for<br />

Class H (180°C) <strong>Ballasts</strong><br />

less than 75°C<br />

75°C < 80°C<br />

80°C < 85°C<br />

85°C < 90°C<br />

90°C < 95°C<br />

95°C < 100°C<br />

etc.<br />

Temperature Range for<br />

Class N (200°C) <strong>Ballasts</strong><br />

less than 95°C<br />

95°C < 100°C<br />

100°C < 105°C<br />

105°C < 110°C<br />

110°C < 115°C<br />

115°C < 120°C<br />

etc.<br />

CERTIFICATIONS____________________________________<br />

Indicates ballast is listed by Underwriters Laboratories,<br />

Inc. in accordance with UL 1029 Standard for HID <strong>Ballasts</strong>.<br />

Each ballast is marked appropriately.<br />

Indicates ballast is component recognized by Underwriters<br />

Laboratories, Inc. in accordance with UL 1029 Standard for<br />

HID <strong>Ballasts</strong>. Each ballast is marked appropriately.<br />

Indicates ballast is certified by Canadian Standards<br />

Association in accordance with CAN/CSA-22.2 No. 74-<br />

92.Each ballast is marked appropriately.<br />

All HID <strong>Ballasts</strong> are designed and manufactured in<br />

accordance with the American National Standards<br />

Institute Standard for HID <strong>Ballasts</strong>, ANSI C82.4.<br />

HID<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-3


HID<br />

HID<br />

Core & Coil Replacement Kits<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Distributor Kits and Replacement Ignitors<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

<strong>Advance</strong> furnishes 120/208/240/277 Quadri-Volt ® core & coil ballasts to allow the stocking distributor to conveniently meet the<br />

replacement and retrofit needs of customers. In addition, <strong>Advance</strong> now offers 120/208/240/277/480 volt 5-TAP core & coil ballasts for<br />

the most popular applications. 5-TAP ballasts add the 480 volt input lead to the Quadri-volt designs. A Quadri-Volt or 5-TAP core &<br />

coil, along with the appropriate capacitor, ignitor (where required), mounting bracket & hardware and installation instructions are packed<br />

in a space-saving shipping carton. These “kits” eliminate the need for distributors or end-users to stock loose components of single<br />

voltage ballasts for 120, 208, 240, 277, and even some 480 volt applications, though single voltage kits for 480 volt applications will also<br />

be available.<br />

Ignitors are also packaged in individual cartons for replacement needs. There are several different ignitors to meet the needs of the<br />

many different lamps. The appropriate ignitor for each ballast is shown in the far right column on the page in this <strong>Atlas</strong> where the ballast<br />

is listed. Additionally, this information is summarized in the tables on pages 5-50 through 5-53.<br />

Pre-wired<br />

Ignitor!<br />

Dry Capacitor<br />

Now Rated 105°C !<br />

Pre-attached<br />

Connectors for<br />

Capacitor!<br />

Dry Capacitors<br />

We have extended the operating voltage range of our dry capacitors from 330 to 400 volts. This<br />

means that our most popular HID replacement kits for 175, 250, and 400-watt metal halide lamps now<br />

contain dry capacitors and offer the additional benefits available only with a dry capacitor.<br />

HID<br />

Those benefits are:<br />

• Dry capacitors are typically 25 to 50% smaller than their oil-filled<br />

counterparts, assuring that the <strong>Advance</strong> ballast kit will fit existing fixtures.<br />

• Dry capacitors are rated 105°C, 15°C higher than 90°C oil-filled capacitors, thus assuring longer<br />

component life.<br />

• Dry capacitors are built using a thermoplastic case, thus eliminating the need for grounding and<br />

insuring a faster, easier replacement.<br />

• Unlike oil-filled capacitors with exposed tab terminals, dry capacitors have no exposed live parts and<br />

thus protect end-users from hazardous voltages.<br />

• For customers who prefer connecting dry capacitors via flag terminals (like oil-filled capacitors are<br />

attached) a new line of dry capacitors with terminals is available. See page 5-48 for a full line of offerings.<br />

The bottom line is that our expanded use of dry capacitors makes the contractor’s job faster and<br />

easier. Look for the “D” at the end of our catalog number, it identifies the ballast kit as one that<br />

contains a dry capacitor!<br />

oil<br />

cap<br />

end comparison<br />

Capacitor Size Comparison<br />

Oil-Filled vs. <strong>Advance</strong> Dry Type<br />

5/8" required clearance for terminals<br />

oil cap<br />

dry<br />

cap<br />

side-by-side comparison<br />

dry<br />

cap<br />

HID<br />

REPLACEMENT KITS<br />

Kit Options<br />

HID Replacement<br />

Ballast Kit<br />

Pages<br />

Includes Core & Coil, Capacitor,<br />

Ignitor (where required), and<br />

Complete Mounting Hardware<br />

for ALL Components<br />

Includes 5-TAP<br />

Ballast Where<br />

Available<br />

Carton Has Space<br />

for A Distributor-<br />

Supplied Lamp<br />

Premium-Grade<br />

Clear Lamp<br />

Included<br />

Easy-Carry Handle<br />

On Carton<br />

71A (standard) 5-5,6,7,8,9<br />

✓ ✓<br />

77K (Val-U-Pak) 5-10<br />

✓ ✓<br />

✓<br />

77L (Val-U-Pak PLUS)<br />

5-11 ✓<br />

✓ ✓<br />

✓<br />

5-4<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil Replacement Kits<br />

HID<br />

METAL HALIDE<br />

New<br />

New<br />

Input<br />

Volts<br />

70 Watt Lamp, ANSI Code M98<br />

120/208/<br />

240/277<br />

71A5292-001D HX-HPF 5.2 ✓ ✓<br />

100 Watt Lamp, ANSI Code M90/M140<br />

120/208/<br />

240/277<br />

71A5390-001D HX-HPF 6.0 ✓ ✓<br />

150 Watt Lamp, ANSI Code M102/M142<br />

120/208/<br />

240/277<br />

71A5492-001D HX-HPF 7.75 ✓ ✓<br />

175/150 Watt Lamp, ANSI Code M57/M107 or H39<br />

120/208/<br />

240/277<br />

71A5570-001D CWA 8.5 ✓ ✓<br />

480 71A5540-001D CWA 8.5 ✓ ✓<br />

175 Watt Lamp, ANSI Code M137/M152<br />

120/208/<br />

240/277<br />

71A5593-001D CWA 10.0 ✓ ✓<br />

200 Watt Lamp, ANSI Code M136<br />

Linear<br />

277 71A5637-001D* 6.0<br />

Reactor HPF<br />

250 Watt Lamp, ANSI Code M58 or H37<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277<br />

Super<br />

71A5692-001D 8.0 ✓ ✓<br />

CWA<br />

71A5770-001D<br />

CWA<br />

4 1 /4 x 4 3 /4<br />

71A5750-001D Core 10.0 ✓ ✓<br />

71A5771-001D<br />

CWA<br />

3x4<br />

Core<br />

Includes -540 bracket. See drawing below for details.<br />

*<br />

CORE & COIL MOUNTING BRACKETS<br />

Included with all Replacement Kits<br />

(See Page 5-6 for addional bracket diagram)<br />

13.0<br />

480 71A5740-001D 12.0<br />

11.0<br />

480 71A5741-001D 10.0<br />

250 Watt Lamp, ANSI Code M138<br />

Linear<br />

277 71A5737-001D<br />

Reactor HPF<br />

120/208/<br />

240/277<br />

Catalog<br />

Number<br />

71A5792-001D<br />

Circuit<br />

Type<br />

50 Watt Lamp, ANSI Code M110/M148<br />

Super<br />

CWA<br />

Total Certifications<br />

Weight<br />

(Lbs)<br />

120/277 71A5181-001D HX-HPF 4.9 ✓ ✓<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277/<br />

480<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

Includes welded-on angle<br />

bracket (-540 option)<br />

standard with -001D kit.<br />

Allows Linear Reactor ballast<br />

to mount in fixtures designed<br />

for standard CWA ballasts<br />

without the need for<br />

additional brackets.<br />

✓<br />

✓<br />

✓<br />

✓<br />

7.0 ✓ ✓<br />

9.0 ✓ ✓<br />

New<br />

METAL HALIDE<br />

320 Watt Lamp, ANSI Code M132<br />

Linear<br />

277 71A5837-001D*<br />

Reactor HPF<br />

120/208/<br />

Super<br />

71A5892-001D<br />

240/277<br />

CWA<br />

350 Watt Lamp, ANSI Code M131<br />

277 71A5937-001D*<br />

Linear<br />

Reactor HPF<br />

10.0 ✓<br />

120/208/<br />

Super<br />

71A5993-001D<br />

240/277<br />

CWA<br />

11.0 ✓ ✓<br />

400 Watt Lamp, ANSI Code M59 or H33<br />

277 71A6037-001D*<br />

Linear<br />

Reactor HPF<br />

9.0 ✓<br />

120/208/<br />

240/277<br />

71A6071-001D CWA 11.5 ✓ ✓<br />

120/208/<br />

240/277/ 71A6051-001D CWA 14.0 ✓ ✓<br />

480<br />

480 71A6041-001D CWA 12.0 ✓ ✓<br />

400 Watt Lamp, ANSI Code M135<br />

277 71A6137-001D*<br />

Linear<br />

9.0 ✓<br />

750 Watt Lamp, ANSI Code M149<br />

277/347/<br />

480<br />

71A64F2-001D CWA 18.7 ✓ ✓<br />

1000 Watt Lamp, ANSI Code M47 or H36<br />

120/208/<br />

240/277<br />

71A6572-001 CWA 28.0 ✓ ✓<br />

120/208/<br />

240/277/ 71A6552-001 CWA 22.0 ✓ ✓<br />

480<br />

480 71A6542-001 CWA 28.0 ✓ ✓<br />

1500 Watt Lamp, ANSI Code M48<br />

120/208/<br />

240/277<br />

71A6772-001 CWA 31.0 ✓ ✓<br />

480 71A6742-001 CWA 31.0 ✓ ✓<br />

Includes -540 bracket. See drawing below for details.<br />

*<br />

Input<br />

Volts<br />

9.5 ✓<br />

11.0 ✓ ✓<br />

480-T 71A5842-001DT SCWA 12.8 ✓ ✓<br />

120/208/<br />

240/277<br />

71A6092-001D<br />

Reactor HPF<br />

Super<br />

CWA<br />

Two 400 Watt Lamps, ANSI Code M59 or H33<br />

120/277 71A6382-001D<br />

CWA<br />

Independent 31.0<br />

480 71A6342-001D<br />

Lamp<br />

Operation 31.0<br />

450 Watt Lamp, ANSI Code M144<br />

Linear<br />

277 71A6337-001D<br />

Reactor HPF<br />

120/208/<br />

240/277<br />

Catalog<br />

Number<br />

71A6393-001D<br />

Circuit<br />

Type<br />

Super<br />

CWA<br />

Total Certifications<br />

Weight<br />

(Lbs)<br />

11.0 ✓ ✓<br />

9.0<br />

11.0<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

HID<br />

REPLACEMENT KITS<br />

-540 Bracket Detail<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-5


HID-CORE & COIL BALLAST REPLACEMENT KITS<br />

HID<br />

REPLACEMENT KITS<br />

New<br />

New<br />

New<br />

New<br />

New<br />

HIGH PRESSURE SODIUM<br />

"B" Suffix Denotes Integral Ignitor<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Total<br />

Weight<br />

(Lbs)<br />

Certifications<br />

35 Watt Lamp, ANSI Code S76<br />

120 71A7707-001DB R-HPF 1.5 ✓ ✓<br />

50 Watt Lamp, ANSI Code S68<br />

120 71A7807-001DB R-HPF 1.9 ✓ ✓<br />

120/277 71A7801-001D HX-HPF 3.5 ✓ ✓<br />

70 Watt Lamp, ANSI Code S62<br />

120 71A7907-001DB R-HPF 2.5 ✓ ✓<br />

120/208/<br />

240/277<br />

71A7971-001D HX-HPF 5.5 ✓ ✓<br />

120/208/<br />

240/277<br />

71A7991-001DC HX-HPF 5.5 ✓ ✓<br />

100 Watt Lamp, ANSI Code S54<br />

120 71A8007-001DB R-HPF 3.1 ✓ ✓<br />

120/208/<br />

240/277<br />

71A8071-001D HX-HPF 7.3 ✓ ✓<br />

120/208/<br />

240/277<br />

71A8091-001DC HX-HPF 7.3 ✓ ✓<br />

480 71A8041-001D HX-HPF 7.0 ✓ ✓<br />

150 Watt Lamp, ANSI Code S55<br />

120 71A8107-001DB R-HPF 4.0 ✓ ✓<br />

120/208/<br />

240/277<br />

71A8172-001D HX-HPF 8.0 ✓ ✓<br />

120/208/<br />

240/277<br />

71A8192-001DC HX-HPF 8.0 ✓ ✓<br />

480 71A8142-001D HX-HPF 9.5 ✓ ✓<br />

150 Watt Lamp, ANSI Code S56<br />

120/208/<br />

240/277<br />

71A8176-001D CWA 8.5 ✓ ✓<br />

480 71A8146-001D CWA 8.5 ✓ ✓<br />

CORE & COIL MOUNTING BRACKETS<br />

Included with Replacement Kits<br />

HPS Kit Options<br />

In addition to the standard kits, this and the following page<br />

include two HPS kits with special features:<br />

HPS Reactor Kits with Integral Ignitors<br />

“B” Suffix (p.5-6) denotes 120V reactor circuit kits featuring singlecoil<br />

reactor ballasts with integral ignitors. The kit includes a mounting<br />

bracket (PC848S) sized specifically for the small reactor ballasts.<br />

Compact<br />

Reactor Core<br />

and Bracket<br />

HPS Kits with Plug-In Ignitors<br />

“C” Suffix (p.5-7) denotes standard HPS kit except with plug-in<br />

ignitor. A mating receptacle is attached to the core and coil lead wires,<br />

ready for immediate connection.<br />

Connectorized<br />

ignitor and<br />

mating<br />

receptable<br />

PC-8485<br />

PC-848S mounting bracket for Figure 9<br />

C0re & Coil ballasts. Bracket and thrubolts<br />

are included in 120V HPS Reactor<br />

Kits.<br />

Bracket<br />

Mounting<br />

Holes<br />

7⁷⁄₁₆"<br />

4³⁄₈"<br />

Ballast<br />

Mounting<br />

Holes<br />

³⁄₄"<br />

PC-849 Mounting<br />

bracket for Fig.2, 3, 8, 8a &10<br />

Core & Coil <strong>Ballasts</strong>.<br />

To order individual packaged<br />

kits, specify PKG 849-2<br />

(2 brackets with thru bolts).<br />

4¹⁄₄"<br />

Spacing<br />

in fixture<br />

power door<br />

3⁷⁄₈"<br />

8"<br />

PC-909 Mounting<br />

bracket for Fig. 2, 3 & 8<br />

Core & Coil <strong>Ballasts</strong><br />

when used with power-door<br />

roadway fixtures.<br />

5-6<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HID-CORE & COIL BALLAST REPLACEMENT KITS<br />

New<br />

New<br />

New<br />

HIGH PRESSURE SODIUM<br />

“C” Suffix Denotes Plug-In Ignitor<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Total<br />

Weight<br />

(Lbs)<br />

Certifications<br />

200 Watt Lamp, ANSI Code S66<br />

120/208/<br />

240/277<br />

71A8970-001D CWA 8.5 ✓ ✓<br />

480 71A8940-001D CWA 8.5 ✓ ✓<br />

250 Watt Lamp, ANSI Code S50<br />

120/208/<br />

240/277<br />

71A8271-001D CWA 11.5 ✓ ✓<br />

120/208/<br />

240/277/ 71A8251-001D CWA 12.0 ✓ ✓<br />

480<br />

120/208/<br />

240/277<br />

71A8291-001DC CWA 11.5 ✓ ✓<br />

480 71A8241-001D CWA 11.0 ✓ ✓<br />

310 Watt Lamp, ANSI Code S67<br />

120/208/<br />

240/277<br />

71A8371-001D CWA 13.8 ✓ ✓<br />

400 Watt Lamp, ANSI Code S51<br />

120/208/<br />

240/277<br />

71A8473-001D CWA 15.0 ✓ ✓<br />

120/208/<br />

240/277/ 71A8453-001D CWA 16.0 ✓ ✓<br />

480<br />

120/208/<br />

240/277<br />

71A8493-001DC CWA 15.0 ✓ ✓<br />

480 71A8443-001D CWA 15.5 ✓ ✓<br />

480 71A8443-001DC CWA 15.5 ✓ ✓<br />

1000 Watt Lamp, ANSI Code S52<br />

120/208/<br />

240/277<br />

71A8773-001 CWA 31.0 ✓ ✓<br />

120/208/<br />

240/277/ 71A8753-001 CWA 29.0 ✓ ✓<br />

480<br />

120/208/<br />

240/277<br />

71A8793-001C CWA 31.0 ✓ ✓<br />

480 71A8743-001 CWA 31.0 ✓ ✓<br />

480 71A8743-001C CWA 31.0 ✓ ✓<br />

New<br />

New<br />

MERCURY<br />

Input<br />

Volts<br />

50 Watt Lamp, ANSI Code H46<br />

120 71A1800-001 HX-NPF 3.3<br />

100 Watt Lamp, ANSI Code H38 or H44<br />

120/208/<br />

71A2571-001D CWA 5.0<br />

240/277<br />

120 71A2800-001 HX-NPF 3.8<br />

175 Watt Lamp, ANSI Code H39<br />

120/208/<br />

240/277<br />

71A3072-001D CWA 6.5 ✓ ✓<br />

480 71A3042-001D CWA 5.0 ✓ ✓<br />

120 71A3301-001 HX-NPF 5.0 ✓ ✓<br />

250 Watt Lamp, ANSI Code H37<br />

120/208/<br />

240/277<br />

71A3572-001D CWA 8.3 ✓ ✓<br />

480 71A3542-001D CWA 7.5 ✓ ✓<br />

400 Watt Lamp, ANSI Code H33<br />

120/208/<br />

240/277<br />

71A4071-001D CWA 12.5 ✓ ✓<br />

480 71A4041-001D CWA 12.0 ✓ ✓<br />

Two 400 Watt Lamps, ANSI Code H33<br />

120 71A4300-001 CWI<br />

277 71A4330-001 (2 lamps 20.3 ✓ ✓<br />

480 71A4340-001 in series)<br />

1000 Watt Lamp, ANSI Code H36<br />

120/208/<br />

240/277<br />

71A5070-001 CWA 24.3 ✓ ✓<br />

480 71A5040-001 CWA 23.0 ✓ ✓<br />

LOW PRESSURE SODIUM<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Circuit<br />

Type<br />

Total Certifications<br />

Weight<br />

(Lbs)<br />

Total<br />

Weight<br />

(Lbs)<br />

Certifications<br />

35 or 55 Watt Lamp, ANSI Code L70 or L71<br />

120/208/<br />

71A0490-001D HX-PFC 7.5 ✓ ✓<br />

240/277<br />

90 WATT LAMP, ANSI CODE L72<br />

120/208/<br />

71A0590-001D HX-HPF 11.0 ✓ ✓<br />

240/277<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

HID<br />

REPLACEMENT KITS<br />

CORE & COIL MOUNTING BRACKETS<br />

Included with Replacement Kits<br />

New<br />

135 or 180 Watt Lamp, ANSI Code L73 or L74<br />

120/208/<br />

71A0790-001D HX-HPF 17.5 ✓ ✓<br />

240/277<br />

Bracket<br />

Mounting<br />

Holes<br />

7⁷⁄₁₆"<br />

4³⁄₈"<br />

Ballast<br />

Mounting<br />

Holes<br />

³⁄₄"<br />

4¹⁄₄"<br />

Spacing<br />

in fixture<br />

power door<br />

3⁷⁄₈"<br />

8"<br />

PC-909 Mounting<br />

bracket for Fig. 2, 3 & 8<br />

Core & Coil <strong>Ballasts</strong><br />

when used with power-door<br />

roadway fixtures.<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-7


HID-EEI NEMA HEAD BALLAST ASSEMBLIES<br />

Input<br />

Volts<br />

Catalog Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Dimensions<br />

Fig A B<br />

Net<br />

Wt<br />

(Ibs)<br />

MERCURY<br />

175 Watt Lamp, ANSI Code H39<br />

120 71A3304-791 HX-NPF 205 3.00<br />

A 1.00 2.3 6.0<br />

240<br />

240 71A3325-791 R-NPF 195 2.70 B 1.75 3.0 5.0<br />

250 Watt Lamp, ANSI Code H37<br />

120 71A3801-791 HX-NPF 285 4.80 240 A 1.65 2.3 7.5<br />

HIGH PRESSURE SODIUM<br />

70 Watt Lamp, ANSI Code S62<br />

120 71A7907-791 R-NPF 86 2.10 120 B 1.50 3.0 3.8<br />

100 Watt Lamp, ANSI Code S54<br />

120 71A8007-791 R-NPF 115 3.05 120 B 1.50 3.0 4.3<br />

150 Watt Lamp, ANSI Code S55<br />

120 71A8107-791 R-NPF 170 4.50 120 B 2.00 3.6 5.3<br />

Note: All NEMA Head ballasts include an ignitor integral to the core & coil. All are NPF and<br />

do not include a capacitor.<br />

HID-EEI<br />

NEMA HEAD<br />

2⁵⁄₈"<br />

MOGUL<br />

SOCKET<br />

MOGUL<br />

SOCKET<br />

8" IGNITOR<br />

3⁵⁄₈"<br />

NOTE: Ignitor<br />

for High<br />

Pressure<br />

Sodium Only<br />

8"<br />

3¹⁄₂"<br />

A<br />

B MAX<br />

1³⁄₄"<br />

A<br />

BALLAST<br />

B-ACROSS COIL<br />

Note: Integral<br />

ignitor included<br />

in ballast<br />

3¹⁵⁄₃₂"<br />

4³⁄₈" 5"<br />

2⁵⁄₈"<br />

4³⁄₈"<br />

5"<br />

Fig. A<br />

Fig. B<br />

5-8<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HID-CORE & COIL REPLACEMENT KITS<br />

MERCURY<br />

FOR CANADA<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Total Certifications<br />

Weight<br />

(Lbs)<br />

METAL HALIDE<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Total<br />

Weight<br />

(Lbs)<br />

70 Watt Lamp, ANSI Code M98<br />

120/<br />

71A52A2-001D HX-HPF 5.0<br />

277/347<br />

100 Watt Lamp, ANSI Code M90<br />

120/<br />

71A53A0-001D HX-HPF 5.5<br />

277/347<br />

Certifications<br />

175/150 Watt Lamp, ANSI Code M57/M107 or H39<br />

120/<br />

71A55A0-001D CWA 7.0 ✓ ✓<br />

277/347<br />

250 Watt Lamp, ANSI Code M58 or H37<br />

120/<br />

71A57A0-001D CWA 10.0<br />

277/347<br />

400 Watt Lamp, ANSI Code M59 or H33<br />

120/<br />

71A60A1-001D CWA 12.0<br />

277/347<br />

1000 Watt Lamp, ANSI Code M47 or H36<br />

120/<br />

71A65A2-001 CWA 21.0<br />

277/347<br />

1500 Watt Lamp, ANSI Code M48<br />

120/<br />

71A67A2-001 CWA 30.0<br />

277/347<br />

Note:<br />

175, 250, and 400-watt metal halide<br />

kits now include dry capacitors!<br />

(see page 5-5 for a full explanation of<br />

the features and benefits of dry capacitors)<br />

CORE & COIL MOUNTING BRACKETS<br />

Included with Replacement Kits<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

NEW<br />

100 Watt Lamp, ANSI Code H38 or H44<br />

120/<br />

71A25A1-001D CWA 5.0<br />

277/347<br />

125 Watt Lamp, ANSI Code H42<br />

120/<br />

71A29D1-001D CWA 5.0<br />

240/347<br />

175 Watt Lamp, ANSI Code H39<br />

120/<br />

71A30D2-001D CWA 5.5<br />

240/347<br />

250 Watt Lamp, ANSI Code H37<br />

120/<br />

71A35D2-001D CWA 7.5<br />

240/347<br />

400 Watt Lamp, ANSI Code H33<br />

120/<br />

71A40D1-001D CWA 10.5<br />

240/347<br />

HIGH PRESSURE SODIUM<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Total<br />

Weight<br />

(Lbs)<br />

70 Watt Lamp, ANSI Code S62<br />

120/<br />

71A79A1-001D HX-HPF 5.5<br />

277/347<br />

100 Watt Lamp, ANSI Code S54<br />

120/<br />

71A80A1-001D HX-HPF 7.5<br />

277/347<br />

150 Watt Lamp, ANSI Code S55<br />

120/<br />

71A81A2-001D HX-HPF 8.0<br />

277/347<br />

250 Watt Lamp, ANSI Code S50<br />

120/<br />

71A82A1-001D CWA 11.5<br />

277/347<br />

400 Watt Lamp, ANSI Code S51<br />

120/<br />

71A84A3-001D CWA 15.0<br />

277/347<br />

1000 Watt Lamp, ANSI Code S52<br />

120/<br />

71A87A3-001 CWA 31.0<br />

277/347<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

Certifications<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

HID REPLACEMENT<br />

KITS<br />

Bracket<br />

Mounting<br />

Holes<br />

7⁷⁄₁₆"<br />

4³⁄₈"<br />

Ballast<br />

Mounting<br />

Holes<br />

³⁄₄"<br />

3⁷⁄₈"<br />

PC-849 Mounting<br />

bracket for Fig.2, 3, 8, 8a &10<br />

Core & Coil <strong>Ballasts</strong>.<br />

To order individual packaged<br />

kits, specify PKG 849-2<br />

(2 brackets with thru bolts).<br />

4¹⁄₄"<br />

Spacing<br />

in fixture<br />

power door<br />

8"<br />

PC-909 Mounting<br />

bracket for Fig. 2, 3 & 8<br />

Core & Coil <strong>Ballasts</strong><br />

when used with power-door<br />

roadway fixtures.<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-9


HID VAL-U-PAK REPLACEMENT KITS<br />

Val-U-Pak replacement kits combine all of the features and<br />

components of our popular HID Replacement Kits into a<br />

new, easy-to-carry carton. In addition, these cartons contain<br />

space to add the lamp of YOUR choosing. Need an open-fixture<br />

rated lamp? Coated lamp? Compact or medium base<br />

lamp? Meet your customer’s specific lamp requirement and<br />

package it with the appropriate <strong>Advance</strong> ballast to better<br />

serve the needs of your contractor and MRO clients!<br />

HID VAL-U-PAK<br />

REPLACEMENT KITS<br />

The <strong>Advance</strong> VAL-U-PAK makes total fixture changeouts<br />

easier - packaging labor-saving convenience in an<br />

easy-to-carry carton.<br />

VAL-U-PAK ® features:<br />

• Convenience - Quadri-Volt core and coil ballast with all<br />

required components and mounting hardware packed together<br />

• Easy Handling - Sturdy handles and heavy duty packaging<br />

• Added Safety - Dry film capacitors<br />

• Quick and Accurate Install with No Live Parts - Ignitors are<br />

all pre-wired in High Pressure Sodium and Pulse-start Metal<br />

Halide Kits, eliminating common wiring errors<br />

• Flexibility - Space to add the lamp YOU choose<br />

HID VAL-U-PAKs are available with<br />

the 11 most popular ADVANCE HID<br />

ballast replacement kits:<br />

HIGH PRESSURE SODIUM<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Total<br />

Weight<br />

(Lbs)<br />

100 Watt Lamp, ANSI Code S54<br />

120/208/<br />

77K8071-001D HX-HPF 7.3<br />

240/277<br />

150 Watt Lamp, ANSI Code S55<br />

120/208/<br />

77K8172-001D HX-HPF 8.0<br />

240/277<br />

250 Watt Lamp, ANSI Code S50<br />

120/208/<br />

77K8271-001D CWA 11.5<br />

240/277<br />

400 Watt Lamp, ANSI Code S51<br />

120/208/<br />

77K8473-001D CWA 15.0<br />

240/277<br />

Certifications<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

PULSE-START METAL HALIDE<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

320 Watt Lamp, ANSI Code M132<br />

Linear<br />

277 77K5837-001D*<br />

Reactor HPF<br />

120/208/<br />

Super<br />

77K5892-001D<br />

240/277<br />

CWA<br />

350 Watt Lamp, ANSI Code M131<br />

Linear<br />

277 77K5937-001D*<br />

Reactor HPF<br />

120/208/<br />

77K5993-001D<br />

240/277<br />

* includes -540 Bracket<br />

METAL HALIDE<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Super<br />

CWA<br />

Circuit<br />

Type<br />

Total<br />

Weight<br />

(Lbs)<br />

9.5 ✓<br />

11.0 ✓ ✓<br />

10.0 ✓<br />

Certifications<br />

11.0 ✓ ✓<br />

Total<br />

Weight<br />

(Lbs)<br />

Certifications<br />

175/150 Watt Lamp, ANSI Code M57/M107 or H39<br />

120/208/<br />

77K5570-001D CWA 8.5 ✓ ✓<br />

240/277<br />

250 Watt Lamp, ANSI Code M58 or H37<br />

120/208/<br />

240/277<br />

77K5770-001D<br />

CWA<br />

4¹⁄₄ x 4³⁄₄<br />

Core<br />

Space for<br />

Distributor<br />

Supplied Lamp<br />

13.0 ✓ ✓<br />

400 Watt Lamp, ANSI Code M59 or H33<br />

120/208/<br />

77K6071-001D CWA 11.5 ✓ ✓<br />

240/277<br />

5-10<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HID VAL-U-PAK PLUS REPLACEMENT KITS<br />

NEW<br />

When standard lamps are all that is needed...<br />

Val-U-Pak Plus Kits feature all of the benefits of<br />

the Val-U-Pak Kits PLUS a whole lot more:<br />

New<br />

New<br />

New<br />

New<br />

Additional Features of Val-U-Pak Plus:<br />

• Added Versatility – 5-Tap core and coil ballast<br />

for the six most popular applications<br />

*Adds the 480V input lead to the Quadri-Volt<br />

*design<br />

• All Inclusive – Premium grade clear lamp<br />

supplied in kit<br />

*Manufactured by major lamp company and<br />

*warranteed by <strong>Advance</strong><br />

• Higher Wattage Options – <strong>Advance</strong> Class N<br />

(200°C) insulation system on 1000W units<br />

provides an additional 20°C margin for high<br />

ambient applications<br />

HID VAL-U-PAKs Plus kits are available for the 9 most popular applications<br />

METAL HALIDE<br />

HIGH PRESSURE SODIUM<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Total<br />

Weight<br />

(Lbs)<br />

Certifications<br />

175/150 Watt Lamp, ANSI Code M57/M107 or H39<br />

120/208/<br />

77L5570-001D CWA 9.5 ✓ ✓<br />

240/277<br />

250 Watt Lamp, ANSI Code M58 or H37<br />

120/208/<br />

240/277/ 77L5750-001D CWA 14.0 ✓ ✓<br />

480<br />

400 Watt Lamp, ANSI Code M59 or H33<br />

120/208/<br />

240/277/ 77L6051-001D CWA 17.0 ✓ ✓<br />

480<br />

1000 Watt Lamp, ANSI Code M47 or H36<br />

120/208/<br />

240/277/<br />

480<br />

77L6552-001 CWA 29.0 ✓ ✓<br />

New<br />

New<br />

New<br />

New<br />

New<br />

HID installations just got simpler, more convenient - and up to<br />

30% faster, with the new Val-U-Pak Plus kits from <strong>Advance</strong>.<br />

Why Should You Change All the Components?<br />

HID fixtures are generally difficult to reach and to service.<br />

Subsequently, the cost of labor can often exceed the cost of the<br />

ballast and/or lamp. When the ballast, capacitor or ignitor reach<br />

end-of-life, it is recommended that all of these components in the<br />

fixture be replaced at the same time. It is equally suggested that<br />

the lamp also be replaced, assuring optimal performance of the<br />

system and eliminating the need to re-service the fixture during<br />

the entire life-cycle of the lamp.<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Total<br />

Weight<br />

(Lbs)<br />

100 Watt Lamp, ANSI Code S54<br />

120/208/<br />

77L8071-001D-MED CWA 8.5<br />

240/277<br />

150 Watt Lamp, ANSI Code S55<br />

120/208/<br />

77L8172-001D-MOG CWA 9.5<br />

240/277<br />

Certifications<br />

250 Watt Lamp, ANSI Code S50<br />

120/208/<br />

240/277/ 77L8251-001D CWA 15.0 ✓ ✓<br />

480<br />

400 Watt Lamp, ANSI Code S51<br />

120/208/<br />

240/277/<br />

480<br />

77L8453-001D CWA 16.0 ✓ ✓<br />

1000 Watt Lamp, ANSI Code S52<br />

120/208/<br />

240/277/ 77L8753-001 CWA 31.0 ✓ ✓<br />

480<br />

✓<br />

✓<br />

✓<br />

✓<br />

HID VAL-U-PAK PLUS<br />

REPLACEMENT KITS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-11


HIGH INTENSITY DISCHARGE BALLASTS<br />

NOTES<br />

HID<br />

5-12<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

ORDERING INFORMATION<br />

How to Order<br />

<strong>Advance</strong> Transformer has developed the industry’s broadest selection of HID ballasts. More than 3000 stocking distributors<br />

nationwide. For information on the distributor best able to serve your needs, please call 800-372-3331.<br />

<strong>Advance</strong> HID Ballast Part Number Explanation<br />

71A 60 9 1<br />

-500D<br />

Suffix Code*<br />

(as applicable)<br />

-001DB ballast replacement kit with dry capacitor and integral ignitor<br />

-001D ballast replacement kit with dry film capacitor<br />

-001 ballast replacement kit with oil filled capacitor<br />

-500D core & coil ballast with dry film capacitor<br />

-500 core & coil ballast with oil filled capacitor<br />

-510D core & coil ballast with welded bracket and dry film capacitor<br />

-510 core & coil ballast with welded bracket and oil filled capacitor<br />

-540D core & coil ballast with welded angle bracket and dry film capacitor<br />

-600 core & coil ballast (no capacitor)<br />

-610 core & coil ballast with welded bracket (no capacitor)<br />

* Add additional feature codes to the end of suffix where applicable.<br />

i.e. -B = Integral Ignitor, -P = Thermally Protected, -J = J-Box Mounting,<br />

-A = Aluminum Secondary Coil, T-120V Tap<br />

Design Code<br />

INPUT<br />

VOLTAGE<br />

CODE<br />

60 Hz Voltages<br />

50 Hz Voltages<br />

0 = 120V A = 120/277/347V<br />

M = 100/200V<br />

1 = 208V B = 347V<br />

N = 120/220-240V<br />

2 = 240V C = 120/347V<br />

R = 220/240V<br />

3 = 277V D = 120/240/347V<br />

4 = 480V E = 120/208/240V or 208/240V<br />

5 = 120/240V or F = 277/480V, 277/347V, 277/347/480V or<br />

120/208/240/277/480V 347/480V<br />

6 = 240/480V H = 127/220V<br />

7 = 120/208/240/277V J = 220V or 220/240V<br />

8 = 120/277V Y = 100V or 100/200V<br />

9 = 120/208/240/277V<br />

HID<br />

Lamp Type/Wattage/Ballast Circuit Code<br />

Ballast<br />

Type<br />

71A = Core and Coil Ballast<br />

72C = F-Can Ballast<br />

73B = Encapsulated Core and Coil Ballast<br />

74P = Postline Ballast<br />

77K = Val-U-Pak Replacement Ballast Kit<br />

77L = Val-U-Pak Plus Replacement Ballast kit (includes lamp)<br />

78E = Indoor Enclosed Ballast<br />

79W = Outdoor Weatherproof Ballast<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-13


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Mercury<br />

Input<br />

Volts<br />

Catalog<br />

✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max<br />

•<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 156-157) to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(Pg 113) 5-3)<br />

50 Watt Lamp, ANSI Code H46<br />

120/277 71A1580 CWA 63 1.1/.5 250 3.2 A 1 1.1 2.3 7 250 7C070L33-R D 3.5 A/A<br />

120<br />

71A1800<br />

71A1800-001<br />

HX-NPF 74 2.1 240 7 B 1 .8 1.9 NOT AVAILABLE<br />

3.0 A<br />

75 Watt Lamp, ANSI Code H43<br />

120/277 71A2080 CWA 93 .9/.4 250 3/1 A 1 1.1 2.3 8 280 7C080L33-R<br />

D 3.5 A/A<br />

120 71A2303 HX-NPF 96 2.6 245 7 B 6 .9 1.9 NOT AVAILABLE<br />

2.8 F<br />

100 Watt Lamp, ANSI Code H38 or H44<br />

120<br />

480<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277<br />

120/<br />

277/347<br />

120/<br />

277/347<br />

71A2501<br />

71A2541<br />

CWA<br />

120<br />

125<br />

71A2591 CWA 125<br />

71A2571-001D CWA 125<br />

71A25A1 CWA 125<br />

71A25A1-001D CWA 125<br />

1.1<br />

.3<br />

1.1/.6/<br />

.6/.5<br />

1.1/.6/<br />

.6/.5<br />

1.1/<br />

.5/.4<br />

1.1/<br />

.5/.4<br />

250<br />

250<br />

250<br />

250<br />

250<br />

3<br />

1<br />

3/2/<br />

2/2<br />

3/2/<br />

2/2<br />

3/<br />

2/1<br />

3/<br />

2/1<br />

A<br />

A<br />

A<br />

A<br />

A<br />

1<br />

1.1<br />

1.2<br />

2.3<br />

2.5<br />

10 280 7C100M33-R D<br />

4.0<br />

4.5<br />

1 1.5 2.8 10 280 7C100M33-R D 5.0<br />

1 1.5 2.8 10 280 7C100M33-R D 5.0<br />

1 1.5 2.8 10 280 7C100M33-R D 5.0<br />

1 1.5 2.8 10 280 7C100M33-R D 5.0<br />

B<br />

D<br />

D/D/<br />

D/D<br />

D/D/<br />

D/D<br />

B/<br />

B/B<br />

B/<br />

B/B<br />

120 71A2800<br />

71A2800-001<br />

HX-NPF 125 3.6 255 8 B1 1 1.4 2.4 NOT AVAILABLE 4.0 B<br />

HID • CORE & COIL<br />

MERCURY<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix<br />

-001 or -001D. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA circuits (except 71A1580, 71A2080), figure is operating current.<br />

For 71A1580 and 71A2080, figure is starting current. For HX and R circuits,<br />

figure is highest of starting, operating or open circuit current.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

LINE V<br />

CAP<br />

COM<br />

LAMP<br />

COM<br />

LAMP<br />

Fig. B<br />

LINE V<br />

CAP<br />

CAP<br />

LAMP<br />

LINE V<br />

LINE V<br />

LINE V<br />

LAMP<br />

LAMP<br />

COM<br />

COM<br />

Fig. A<br />

5-14<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Mercury<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max•<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(Pg 5-3)<br />

125 Watt Lamp, ANSI Code H42<br />

120/<br />

240/347<br />

71A29D1 CWA 150<br />

1.3/<br />

.7/.5<br />

255<br />

4/<br />

2/2<br />

A<br />

1 1.4 2.5 12 280 7C120M33-R D 5.0<br />

B/<br />

B/A<br />

120/<br />

240/347<br />

71A29D1-001D CWA 150<br />

1.3/<br />

.7/.5<br />

255<br />

4/<br />

2/2<br />

A<br />

1 1.4 2.5 12 280 7C120M33-R D 5.0<br />

B/<br />

B/A<br />

175 Watt Lamp, ANSI Code H39<br />

or 150 Watt HPS Lamp, ANSI Code S63, EZ Lux (GE), Unalux (Osram-Sylvania), Retrolux (Philips)<br />

120 71A3002 CWA 205 1.9 215 5 A 1 1.6 2.9 17.5 240 7C175M33-R D 5.0 B<br />

NOM<br />

480<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277<br />

120/<br />

240/347<br />

120/<br />

240/347<br />

71A3042<br />

71A3042-001D<br />

71A3092<br />

CWA<br />

CWA<br />

205<br />

200<br />

1.9/1.1/<br />

1.0/.9<br />

1.7/<br />

.9/.6<br />

1.7/<br />

.9/.6<br />

215<br />

240<br />

5/3/<br />

3/2<br />

5/<br />

3/2<br />

120<br />

71A3301<br />

71A3301-001<br />

HX-NPF 200 6.0 240 15 B1 1 1.4 2.5 NOT AVAILABLE<br />

4.5 B<br />

240 71A3325 R-NPF 195 2.7 240 7 C1 9 1.8 3.0 NOT AVAILABLE 3.5 D<br />

1<br />

1<br />

1.6<br />

1.7<br />

2.9<br />

2.9<br />

17.5<br />

17.5<br />

240<br />

240<br />

7C175M33-R<br />

1.9/1.1/<br />

5/3/<br />

71A3072-001D CWA 205<br />

215<br />

A 1 1.6 2.9 17.5 240 7C175M33-R D 5.0<br />

1.0/.9<br />

3/2<br />

71A30D2<br />

71A30D2-001D<br />

CWA 200 .5 240 2 A 1 1.8 2.9 17.5 240 7C175M33-R D 5.5 A<br />

CWA 200<br />

240<br />

5/<br />

3/2<br />

A<br />

A<br />

A<br />

7C175M33-R<br />

1 1.7 2.9 17.5 240 7C175M33-R D<br />

D<br />

D<br />

5.0<br />

5.5<br />

5.5<br />

B/C/<br />

C/C<br />

B/C/<br />

C/C<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001<br />

or -001D. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA circuits, figure is operating current. For HX and R circuits, figure<br />

is highest of starting, operating or open circuit current.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

2 7 /16"<br />

B<br />

MAX.<br />

3 1 /2" 3 15 /16"<br />

A<br />

2 13 /16"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

Fig. 1<br />

(3" x 4" core)<br />

HID • CORE & COIL<br />

MERCURY<br />

B<br />

MAX.<br />

4 3 /32"<br />

A<br />

2 5 /32"<br />

Fig. 6<br />

(2" x 4 " core)<br />

3 /4"<br />

B<br />

MAX.<br />

A<br />

2 3 /16"<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

2 3 /16"<br />

2 5 /8" Fig. 9<br />

(2 5 /8" x 2 3 /16 Reactor Core )<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1,6 5.1 1.00 4.50 0.25<br />

9 4.0 0.75 3.50 0.28<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-15


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Mercury<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max•<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(Pg 5-3)<br />

250 Watt Lamp, ANSI Code H37<br />

120 71A3502 CWA 285 2.5 250 8 A 1 2.0 3.2 22.5 280 7C225P30-R D 6.0 D<br />

480<br />

71A3542<br />

71A3542-001D<br />

CWA 285 .7 250 2 A 1 2.3 3.4 22.5 280 7C225P30-R D 7.0 D<br />

480/120T 71A3542-T CWA 285 .7 250 2 A 1 2.3 3.4 22.5 280 7C225P30-R D 7.0 D<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277<br />

120/<br />

240/347<br />

120/<br />

240/347<br />

71A3592 CWA 285<br />

71A3572-001D CWA 285<br />

71A35D2 CWA 285<br />

71A35D2-001D CWA 285<br />

2.5/1.4/<br />

1.3/1.1<br />

2.5/1.4/<br />

1.3/1.1<br />

2.5/<br />

1.3/.9<br />

2.5/<br />

1.3/.9<br />

250<br />

250<br />

250<br />

250<br />

8/5/<br />

5/3<br />

8/5/<br />

5/3<br />

8/<br />

5/3<br />

8/<br />

5/3<br />

A<br />

A<br />

A<br />

A<br />

1 2.5 3.7 22.5 280 7C225P30-R D 7.5<br />

1 2.5 3.7 22.5 280 7C225P30-R D 7.5<br />

1 2.5 3.7 22.5 280 7C225P30-R D 7.5<br />

1 2.5 3.7 22.5 280 7C225P30-R D 7.5<br />

120 71A3802 HX-NPF 285 6.9 235 20 B1 5 1.2 2.4 NOT AVAILABLE 6.0 B<br />

D/D/<br />

D/D<br />

D/D/<br />

D/D<br />

D/<br />

D/D<br />

D/<br />

D/D<br />

NOM<br />

220 71A35J2 CWA 285 1.6 250 5 A 1 2.0 3.2 22.5 280 7C225P30-R D 6.0 D<br />

HID • CORE & COIL<br />

MERCURY<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA circuits, figure is operating current. For HX and R circuits, figure<br />

is highest of starting, operating or open circuit current.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

LINE V<br />

CAP<br />

CAP<br />

LAMP<br />

B<br />

MAX.<br />

A<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

B<br />

MAX.<br />

2 7 /16"<br />

B<br />

MAX.<br />

3 1 /2" 3 15 /16"<br />

A<br />

A<br />

2 13 /16"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

Fig. 1<br />

(3" x 4" core)<br />

3 1 /2"<br />

LINE V<br />

4 1 /4"<br />

LINE V<br />

LINE V<br />

COM<br />

Fig. A<br />

COM<br />

LAMP<br />

3 7 /8"<br />

4 3 /8" 4 3 /4"<br />

Fig. 2<br />

(4 1 /4" x 4 3 /4" core)<br />

4 15 /32"<br />

Fig. 5<br />

(3 1 /2" x 4 1 /2" NEMA Core)<br />

B<br />

MAX.<br />

A<br />

8 Holes cleared for<br />

#10 thru-bolts<br />

WELDED BRACKET DIMENSIONS<br />

3 7 /8"<br />

4 1 /4"<br />

4 3 /8"<br />

5 3 /8" 6 "<br />

Fig. 8<br />

(4 1 /4" x 6" core)<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

5-16<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Mercury<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max•<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

U.L. Bench Top<br />

Rise Code 1029<br />

(Pg 5-3)<br />

Class H<br />

(180°C)<br />

ADVANCE<br />

Class N<br />

(200°C)<br />

400 Watt Lamp, ANSI Code H33<br />

71A4041<br />

480<br />

CWA 454 1.0 245 5 A 2 1.7 3.2 35 240 7C350P30-R D 10.0 D<br />

71A4041-001D<br />

480/120T 71A4041-T CWA 454 1.0 245 5 A 2 1.7 3.2 35 240 7C350P30-R D 10.0 D<br />

—<br />

—<br />

120/208/<br />

240/277<br />

71A4091 CWA 454<br />

3.9/2.2/<br />

2.0/1.7<br />

245<br />

10/8/<br />

5/5<br />

A<br />

2 1.8 3.3 35 240 7C350P30-R D 10.5<br />

D/C/<br />

C/B<br />

—<br />

N<br />

N<br />

120/208/<br />

240/277<br />

120/<br />

240/347<br />

120/<br />

240/347<br />

71A4071-001D CWA 454<br />

71A40D1 CWA 454<br />

71A40D1-001D CWA 454<br />

3.9/2.2/<br />

2.0/1.7<br />

3.9/<br />

2.0/1.3<br />

3.9/<br />

2.0/1.3<br />

245<br />

245<br />

245<br />

10/8/<br />

5/5<br />

10/<br />

5/4<br />

10/<br />

5/4<br />

A<br />

A<br />

A<br />

2 1.8 3.3 35 240 7C350P30-R D 10.5<br />

2 1.8 3.3 35 240 7C350P30-R D 10.5<br />

2 1.8 3.3 35 240 7C350P30-R D 10.5<br />

Two 400 Watt Lamps, ANSI Code H33 (2 Lamps in Series)<br />

120 71A4300-001 CWI 880 7.5 495 20 D 3 2.9 4.4 16 525 MD1606-100 O 20.3 E<br />

277 71A4330-001 CWI 880 3.3 495 10 D 3 2.9 4.4 16 525 MD1606-100 O 20.3 D<br />

480 71A4340-001 CWI 880 1.9 495 5 D 3 2.9 4.4 16 525 MD1606-100 O 20.3 E<br />

1000 Watt Lamp, ANSI Code H36<br />

480 71A5040-001 CWA 1080 2.3 425 10 A 8 2.9 4.8 24 450 MD2409-100 O 25.0 A<br />

120/208/<br />

240/277<br />

71A5070-001 CWA 1075<br />

9.8/5.6/<br />

4.9/4.3<br />

425<br />

20/15/<br />

10/10<br />

A<br />

8 2.9 4.8 24 450 MD2409-100 O 25.0<br />

D/C/<br />

C/B<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

C/C/<br />

B/C<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

A<br />

A/A/<br />

A/A<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with<br />

suffix -001 or -001D. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA and CWI circuits, figure is operating current.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />

Refer to page 5-3 for additional information.<br />

HID • CORE & COIL<br />

MERCURY<br />

LINE V<br />

CAP<br />

CAP<br />

LAMP<br />

LINE V<br />

CAP<br />

CAP<br />

LAMP<br />

LINE V<br />

LAMP<br />

LINE V<br />

LINE V<br />

COM<br />

Fig. A<br />

COM<br />

LAMP<br />

LINE V<br />

Fig. D<br />

LAMP<br />

LAMP<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

2 6.5 1.25 5.75 0.28<br />

3, 8 7.8 2.75 6.13 0.25<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-17


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Metal Halide<br />

NOM<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

120 71A5005-P✥ HX-NPF<br />

HX-HPF<br />

277<br />

277<br />

71A5037-BP✥<br />

71A5037-J✥<br />

Watts<br />

Input<br />

35/39 Watt Lamp, ANSI Code M130<br />

55<br />

48<br />

48<br />

Max •<br />

Input<br />

Current<br />

1.5<br />

1.1<br />

1.6/.7<br />

.9/.4<br />

.7<br />

.6<br />

.7<br />

.6<br />

.7<br />

.6<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

230<br />

277<br />

277<br />

Fuse<br />

Rating<br />

(Amps)<br />

4<br />

3<br />

Wiring<br />

Dia<br />

Fig<br />

Dimensions<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

6 .9 1.8 28 120 7C280M12 D<br />

Total<br />

Weight<br />

(Ibs)<br />

2.0<br />

2.2<br />

3.3<br />

3.5<br />

1.6<br />

1.8<br />

1.7<br />

1.9<br />

1.9<br />

2.0<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

LI533-H4 15 A<br />

HX-NPF<br />

4/2<br />

120/277 71A5081<br />

56<br />

230<br />

K 1 .8 2.1 5 280 7C050L33 D<br />

LI533-H4 15 B/A<br />

HX-HPF<br />

3/1<br />

R-NPF<br />

277 71A5037-P✥<br />

48<br />

277 2 G 9 .8 1.9 5 280 7C050L33 D<br />

R-HPF<br />

LI533-H4 10 A<br />

R-NPF<br />

R-HPF<br />

R-NPF<br />

R-HPF<br />

2<br />

2<br />

F<br />

H<br />

J<br />

9<br />

11<br />

1.0<br />

1.0<br />

2.7<br />

3.0<br />

5<br />

5<br />

280<br />

280<br />

7C050L33<br />

7C050L33<br />

D<br />

D<br />

Integral Ignitor<br />

J-Box with<br />

Integral Ignitor<br />

2<br />

2<br />

A<br />

A<br />

50 Watt Lamp, ANSI Code M110 or M148<br />

120 71A5105-P✥ HX-NPF<br />

HX-HPF<br />

120/277 71A5181<br />

71A5181-001D<br />

277<br />

277<br />

277<br />

71A5137-P✥<br />

71A5137-BP✥<br />

71A5137-J✥<br />

69<br />

2.0<br />

1.1<br />

260<br />

5<br />

3<br />

6 1.0 1.9 28 120 7C280M12 D 2.3 LI533-H4 15 A<br />

HX-HPF 72 1.0/.5 260 3/2 K 1 1.2 2.1 6 280 7C060L33 D 4.0 LI533-H4 10 A/A<br />

R-NPF<br />

R-HPF<br />

R-NPF<br />

R-HPF<br />

R-NPF<br />

R-HPF<br />

62<br />

62<br />

62<br />

.7<br />

.6<br />

.7<br />

.6<br />

.7<br />

.6<br />

277<br />

277<br />

277<br />

2<br />

2<br />

2<br />

F<br />

G<br />

H<br />

J<br />

9<br />

9<br />

11<br />

1.1<br />

1.1<br />

1.1<br />

2.2<br />

2.6<br />

3.3<br />

5<br />

5<br />

5<br />

280<br />

280<br />

280<br />

7C050L33<br />

7C050L33<br />

7C050L33<br />

D<br />

D<br />

D<br />

2.0<br />

2.2<br />

2.0<br />

2.2<br />

2.3<br />

2.5<br />

LI533-H4<br />

Integral Ignitor<br />

J-Box with<br />

Integral Ignitor<br />

2<br />

2<br />

2<br />

A<br />

A<br />

C<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For HX and R circuits, figure is highest of starting, operating or open circuit current.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor<br />

model shown for use within fixtures. If a Long Range ignitor is required for remote<br />

mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />

✥ Includes auto-reset thermal protection<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

120 V<br />

COM<br />

Fig. F<br />

LAMP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

COM<br />

INTEGRAL<br />

IGNITOR INTEGRATED BALLAST<br />

IGNITOR BALLAST<br />

LINE V<br />

LAMP<br />

IGNITOR<br />

CAP<br />

COM<br />

Fig. FIG. H<br />

LAMP<br />

CAP<br />

LAMP<br />

LAMP<br />

LINE V<br />

LAMP<br />

COM<br />

LINE V<br />

(OPTIONAL)<br />

CAP<br />

X3<br />

IGNITOR<br />

X2<br />

X1<br />

LAMP<br />

COM<br />

CAP<br />

LINE V<br />

LINE V<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

CAP<br />

LINE V<br />

LINE V<br />

COM<br />

J-BOX BALLAST<br />

COM<br />

COM<br />

COM<br />

Fig. G<br />

Fig. J<br />

J-BOX<br />

Fig. K<br />

5-18<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Metal Halide<br />

NOM<br />

NOM<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

70 Watt Lamp, ANSI Code M98 (Medium Base) or M143<br />

120 71A5205-P✥ HX-NPF 94<br />

HX-PFC<br />

120/277 71A5282<br />

HX-HPF 90<br />

127/220 71A52H2<br />

120/208/<br />

240/277<br />

2.6<br />

1.4<br />

1.9/.8<br />

1.9/.9<br />

71A5292<br />

71A5292-001D HX-HPF 90 1.9/1.0/<br />

.9/.8<br />

120/<br />

277/347 71A52A2 HX-HPF 90 1.9/<br />

.8/.7<br />

120/<br />

277/347 71A52A2-001D HX-HPF 90 1.9/<br />

.8/.7<br />

277<br />

277<br />

277<br />

71A5237-P✥<br />

71A5237-BP✥<br />

71A5237-J✥<br />

255<br />

6<br />

4<br />

Wiring<br />

Dia<br />

Fig<br />

Dimensions<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

6 1.6 2.7 36 120 7C360M12 D<br />

Total<br />

Weight<br />

(Ibs)<br />

3.5<br />

3.7<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

LI533-H4 10 B<br />

255 4/2 K 1 1.5 2.8 8 280 7C080L33-R D 5.0 LI533-H4 15 A/A<br />

255<br />

255<br />

255<br />

70 Watt Lamp, ANSI Code M85 (OSI Briteline/HQI, GE MQI ARC70/TD, Philips MHN70/TD)<br />

4/3/<br />

2/2<br />

4/<br />

2/2<br />

4/<br />

2/2<br />

3<br />

2<br />

3<br />

2<br />

3<br />

2<br />

70 Watt Lamp, ANSI Code M139 (Philips CDM70/T6, CDM70/TD)<br />

120/277 71A5281<br />

120/347 71A52C1<br />

120/277 71A5280<br />

120/347 71A52C0<br />

HX-HPF 94<br />

1.6/.7<br />

1.6/.6<br />

245<br />

220<br />

4/2<br />

4/2<br />

F<br />

K<br />

K<br />

K<br />

K<br />

1 1.5 2.8 8 280 7C080L33-R D 5.0 LI533-H4 15<br />

1 1.5 2.8 8 280 7C080L33-R D 5.0 LI533-H4 15<br />

1 1.5 2.8 8 280 7C080L33-R D 5.0 LI533-H4 15<br />

1 1.5<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

1 3 /4"<br />

• For HX and R circuits, figure is highest of starting, operating or open<br />

circuit current.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />

ignitor model shown for use within fixtures. If a Long Range<br />

ignitor is required for remote mounting, specify on order. See pages<br />

5-50 to 5-53 for additional information.<br />

Canadian replacement/retrofit ballast kit indicated by bold type. Refer to page 5-10.<br />

✥ Includes auto-reset thermal protection<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

A<br />

B<br />

R-NPF<br />

R-HPF<br />

R-NPF<br />

R-HPF<br />

R-NPF<br />

R-HPF<br />

1 / 2 "<br />

1 / 2 "-14<br />

STRAIGHT PIPETHREAD<br />

2 5 / 8 "<br />

Fig. 11<br />

J-Box Ballast<br />

85<br />

85<br />

85<br />

HX-HPF 94<br />

2 3 / 16 "<br />

1 27 / 32 "<br />

1.2<br />

.8<br />

1.2<br />

.8<br />

1.2<br />

.8<br />

1.6/.7<br />

1.6/.6<br />

1 13 / 16<br />

277<br />

277<br />

277<br />

245<br />

220<br />

4/2<br />

4/2<br />

B<br />

MAX.<br />

G<br />

H<br />

J<br />

K<br />

9<br />

9<br />

11<br />

4 3 /32"<br />

A<br />

1.6<br />

1.5<br />

1.5<br />

1 1.5<br />

2 5 /32"<br />

2.7<br />

2.9<br />

3.5<br />

2.7<br />

2.8<br />

2.7<br />

2.8<br />

8<br />

8<br />

8<br />

8 280 7C080L33-R D 5.5 LI522-H5 30<br />

B<br />

MAX.<br />

Fig. 6<br />

(2" x 4 " core)<br />

2 3 /16"<br />

280<br />

280<br />

280<br />

A<br />

7C080L33-R<br />

7C080L33-R<br />

7C080L33-R<br />

2 3 /16"<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

2 5 /8" Fig. 9<br />

(2 5 /8" x 2 3 /16 Reactor Core )<br />

D<br />

D<br />

D<br />

2 7 /16"<br />

2.7<br />

2.9<br />

2.7<br />

2.9<br />

3.0<br />

3.2<br />

B<br />

MAX.<br />

LI533-H4<br />

Integral Ignitor<br />

J-Box with<br />

Integral Ignitor<br />

8 280 7C080L33-R D 5.5 LI533-H4<br />

3 1 /2" 3 15 /16"<br />

WELDED BRACKET DIMENSIONS<br />

A<br />

2 13 /16"<br />

Fig. 1<br />

(3" x 4" core)<br />

A/A/<br />

A/A<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

A/A<br />

A/A<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1, 6 5.1 1.00 4.50 0.25<br />

9 4.0 0.75 3.50 0.28<br />

11 Not Available<br />

10<br />

2<br />

2<br />

10<br />

5<br />

A<br />

A<br />

C<br />

A/A<br />

A/A<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-19


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Metal Halide<br />

NOM<br />

NOM<br />

Input<br />

Volts<br />

480/<br />

120T<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

100 Watt Lamp, ANSI Code M90 or M140<br />

120/277<br />

127/220<br />

120/208/<br />

240/277<br />

120/<br />

277/347<br />

71A5380<br />

71A53H0<br />

71A5390<br />

71A5390-001D<br />

HX-HPF<br />

HX-HPF<br />

129<br />

129<br />

HX-HPF 129<br />

2.3/1.0<br />

2.2/1.3<br />

2.3/1.4/<br />

1.2/1.0<br />

71A53A0<br />

71A53A0-001D HX-HPF 129 2.6/<br />

1.2/1.0<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

265<br />

280<br />

265<br />

280<br />

Fuse<br />

Rating<br />

(Amps)<br />

6/3<br />

5/3<br />

6/4/<br />

3/3<br />

6/<br />

3/2<br />

Wiring<br />

Dia<br />

K<br />

K<br />

K<br />

K<br />

Fig<br />

Dimensions<br />

1<br />

1<br />

Cap Catalog<br />

Number<br />

71A5340-T HX-HPF 132 .6 260 2 K 1 1.7 2.9 10 300 7C100M33-R D 5.5 LI533-H4 25 C<br />

120/277 71A5383 CWA 128 1.1/.5 222 3/2 M 1 1.6 2.8 10 330 7C100M33-R D 5.5 LI533-H4 2 C/C<br />

A<br />

1.5<br />

1.7<br />

B<br />

2.8<br />

2.9<br />

Mfd<br />

12<br />

12<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

280<br />

280<br />

7C120M33-R<br />

7C120M33-R<br />

Dry<br />

or<br />

Oil<br />

1 1.5 2.8 12 280 7C120M33-R D<br />

1 1.7 2.9 12 280 7C120M33-R D<br />

D<br />

D<br />

Total<br />

Weight<br />

(Ibs)<br />

5.5<br />

5.5<br />

5.5<br />

5.5<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

LI533-H4<br />

LI533-H4<br />

LI533-H4<br />

LI533-H4<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

20<br />

20<br />

20<br />

25<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

B/A<br />

A/B<br />

B/C/<br />

A/A<br />

B/<br />

B/B<br />

277<br />

277<br />

277<br />

71A5337-P✥<br />

71A5337-BP✥<br />

71A5337-J✥<br />

R-NPF<br />

R-HPF<br />

R-NPF<br />

R-HPF<br />

R-NPF<br />

R-HPF<br />

118<br />

118<br />

118<br />

1.3<br />

1.1<br />

1.3<br />

1.1<br />

1.3<br />

1.1<br />

277<br />

277<br />

277<br />

3<br />

3<br />

3<br />

G<br />

H<br />

J<br />

9<br />

9<br />

11<br />

1.7<br />

1.8<br />

1.8<br />

2.8<br />

3.1<br />

3.9<br />

10<br />

10<br />

10<br />

280<br />

280<br />

280<br />

7C100M33-R<br />

7C100M33-R<br />

7C100M33-R<br />

D<br />

D<br />

D<br />

3.0<br />

3.2<br />

3.0<br />

3.2<br />

3.3<br />

3.5<br />

LI533-H4<br />

Integral Ignitor<br />

J-Box with<br />

Integral Ignitor<br />

2<br />

2<br />

2<br />

A<br />

A<br />

C<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor) (71A5337 only)<br />

• For CWA circuits, figure is operating current. For HX and R circuits, figure is highest of starting,<br />

operating or open circuit current.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

LINE V<br />

LAMP<br />

LAMP<br />

COM<br />

✝✝ Each ballast requiring an ignitor is furnished standard<br />

with the Short Range ignitor model shown for<br />

use within fixtures. If a Long Range ignitor is<br />

required for remote mounting, specify on order. See<br />

pages 5-50 to 5-53 for additional information.<br />

Canadian replacement/retrofit ballast kit indicated<br />

by bold type. Refer to page 5-10.<br />

✥ Includes auto-reset thermal protection<br />

LINE V<br />

LINE V<br />

LAMP<br />

(OPTIONAL)<br />

CAP<br />

X3<br />

X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

LINE V<br />

LINE V<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

COM<br />

CAP<br />

LINE V<br />

CAP<br />

CAP<br />

CAP<br />

Fig. G<br />

J-BOX BALLAST<br />

Fig. J<br />

J-BOX<br />

COM<br />

COM<br />

Fig. L<br />

INTEGRATED<br />

IGNITOR BALLAST<br />

LINE V<br />

LAMP<br />

CAP<br />

LAMP<br />

LINE V<br />

LAMP<br />

LINE V<br />

LINE V<br />

IGNITOR<br />

CAP<br />

INTEGRAL<br />

IGNITOR BALLAST<br />

COM<br />

LAMP<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

CAP<br />

CAP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

COM<br />

LAMP<br />

COM<br />

CAP<br />

LINE V<br />

LINE V<br />

LINE V<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

Fig. H<br />

Fig. M<br />

COM<br />

COM<br />

Fig. K<br />

5-20<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Metal Halide<br />

NOM<br />

New<br />

NOM<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Fig<br />

Dimensions<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

150 Watt Lamp, ANSI Code M102 or M142<br />

120/277 71A5482 HX-HPF 185 3.7/1.6 265 10/4 K 1 2.3 3.9 16 280 7C160M33 D 7.0 LI533-H4 10<br />

120/208/<br />

240/277<br />

480/<br />

120T<br />

71A5492<br />

71A5492-001D HX-HPF 185 3.7/2.1/<br />

1.8/1.6<br />

120/<br />

277/347 71A54A2 HX-HPF 185 3.7/<br />

1.6/1.3<br />

265<br />

265<br />

10/5/<br />

5/4<br />

10/<br />

4/3<br />

1 2.3 3.9 16 280 7C160M33 D<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

1 2.3 3.9 16 280 7C160M33 D 7.0 LI533-H4 10<br />

Linear<br />

277 71A5437-P✥ Reactor 173 1.5 277 4 G 9 2.5 3.8 14 280 7C140M33-R<br />

HPF<br />

Linear<br />

277 71A5437-BP✥ Reactor 173 1.5 277 4 H 9 2.5 4.0 14 280 7C140M33-R<br />

HPF<br />

Linear<br />

277 71A5437-J✥ Reactor 173 1.5 277 4 J 11 2.5 4.5 14 280 7C140M33-R<br />

HPF<br />

150 Watt Lamp, ANSI Code M81 (OSI Briteline/HQI, GE Arcstream MQI, Philips MHN-TD)<br />

120/277 71A5480 HX-HPF 185 3.6/1.7 240 9/4 K 1 2.5 3.8 16 300 7C160M33<br />

120/208/<br />

3.6/2.1/ 9/6/<br />

71A5490 HX-HPF 185<br />

240<br />

240/277<br />

1.8/1.6<br />

5/4<br />

K 1 2.5 3.8 16 300 7C160M33<br />

120/347 71A54C0 HX-HPF 185 3.6/1.30 240 9/4 K 1 2.5 3.8 16 300 7C160M33<br />

L<br />

K<br />

K<br />

7.0 LI533-H4 10<br />

71A5442-T HX-HPF 185 .9 270 3 K 1 2.8 4.0 16 280 7C160M33 D 9.0 LI533-H4 10<br />

120/<br />

277/347 71A54A3 Super<br />

CWA<br />

189<br />

1.7/<br />

.8/.7<br />

187 5/2/2 L1 1 2.7 4.0 22 240 7C220M24-R D 9.0 LI501-J4 15<br />

D<br />

D<br />

D<br />

8.5<br />

8.5<br />

8.5<br />

LI522-H5<br />

LI522-H5<br />

LI522-H5<br />

20<br />

20<br />

20<br />

C/A<br />

C/C/<br />

A/A<br />

F/E<br />

120/277 71A5486 CWA 189 1.7/.8 187 5/2 1 2.7 4.0 22.5 240 7C225P30-R D 9.0 LI523-H5 2 F/E<br />

D<br />

D<br />

D<br />

4.2<br />

4.2<br />

4.5<br />

LI533-H4<br />

Integral Ignitor<br />

J-Box with<br />

Integral Ignitor<br />

15<br />

15<br />

15<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

C/B<br />

C/C/<br />

C/C<br />

B<br />

E/<br />

E/E<br />

C/<br />

B/A<br />

B<br />

B<br />

B<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA circuits, figure is operating current. For HX and Linear Reactor circuits, figure is highest of<br />

starting, operating or open circuit current.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor model shown<br />

for use within fixtures. If a Long Range ignitor is required for remote mounting, specify on order.<br />

See pages 5-50 to 5-53 for additional information.<br />

✥ Includes auto-reset thermal protection<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

2 7 /16"<br />

B<br />

MAX.<br />

3 1 /2" 3 15 /16"<br />

A<br />

2 13 /16"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

Fig. 1<br />

(3" x 4" core)<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

B<br />

MAX.<br />

A<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

1 3 /4"<br />

2 3 /16"<br />

2 3 /16"<br />

2 5 /8" Fig. 9<br />

(2 5 /8" x 2 3 /16 Reactor Core )<br />

A<br />

B<br />

1 / 2 "<br />

2 5 / 8 "<br />

1 / 2 "-14<br />

STRAIGHT PIPETHREAD<br />

Fig. 11<br />

2 3 / 16 "<br />

1 27 / 32 "<br />

1 13 / 16 "<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

9 4.0 0.75 3.50 0.28<br />

11 Not Available<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-21


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

Metal Halide<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

LINE V<br />

LINE V<br />

LINE V<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

LAMP 1<br />

X3<br />

X1<br />

X2<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

IGNITOR<br />

Fuse<br />

Rating<br />

(Amps)<br />

LAMP<br />

Wiring<br />

Dia<br />

Dimensions<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA and Regulated Lag circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />

ignitor model shown for use within fixtures. If a Long Range ignitor is<br />

required for remote mounting, specify on order. See pages 5-50 to 5-53 for<br />

additional information.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

Fig<br />

LINE V<br />

Mfd<br />

INTEGRATED<br />

INTEGRAL<br />

IGNITOR BALLAST<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

LAMP<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

Dry<br />

or<br />

Oil<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

Total<br />

Weight<br />

(Ibs)<br />

CAP<br />

CAP<br />

Fig. A<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

CAP<br />

Part<br />

Number<br />

480<br />

71A5540<br />

71A5540-001D<br />

CWA 210 0.5 305 2 A 1 2.5 4.0 10 400 7C100M40-R D 8.5 — — D<br />

480/120T 71A5540-T CWA 210 0.5 305 2 A 1 2.8 4.0 10 400 7C100M40-R D 8.5 — — D<br />

120/277 71A5580 CWA 210 1.8/.8 305 5/2 A 1 2.5 3.9 10 400 7C100M40-R D 6.8 — — C/D<br />

NOM 127/220 71A55H0 CWA 210 1.8/1.1 305 5/3 A 1 2.5 3.8 10 400 7C100M40-R D 6.8 — — B/B<br />

NOM<br />

NOM<br />

New<br />

175 Watt Lamp, ANSI Code M57 or H39; or 150 Watt Lamp, ANSI Code M107<br />

120<br />

277<br />

71A5500<br />

71A5530<br />

CWA 210<br />

1.8<br />

.8<br />

120/208/<br />

240/277 71A5590 CWA 210 1.8/1.1/<br />

.9/.8<br />

120/208/<br />

240/277 71A5570-001D CWA 210 1.8/1.1/<br />

.9/.8<br />

120/<br />

277/347 71A55A0 CWA 210 1.8/<br />

.8/.7<br />

120/<br />

277/347 71A55A0-001D CWA 210 1.8/<br />

.8/.7<br />

305<br />

305<br />

305<br />

305<br />

5<br />

2<br />

5/3/<br />

3/2<br />

5/3/<br />

3/2<br />

5/<br />

2/2<br />

175 Watt Lamp, ANSI Code M137 or M152 (Pulse-Start)<br />

120/208/ 71A5593<br />

240/277 71A5593-001D<br />

120 71A5504<br />

277/120T 71A5534-T<br />

347/120T 71A55B4-T<br />

480/120T 71A5544-T<br />

Super<br />

CWA<br />

120/<br />

277/347 71A55A3 Super<br />

CWA<br />

480/120T 71A5543-T<br />

Super<br />

CWA<br />

Regulated<br />

Lag<br />

208<br />

208<br />

220<br />

1.9/1.1/<br />

.9/.8<br />

1.9/<br />

.9/.7<br />

2.0<br />

0.8<br />

0.7<br />

0.5<br />

305<br />

275<br />

275<br />

310<br />

5/<br />

2/2<br />

5/3/<br />

3/3<br />

5/<br />

3/2<br />

5<br />

2<br />

2<br />

1<br />

A<br />

A<br />

A<br />

A<br />

A<br />

M<br />

M<br />

N<br />

A<br />

B<br />

CAP<br />

COM<br />

CAP<br />

Fig. M<br />

LAMP<br />

X3<br />

COM<br />

X1<br />

IGNITOR<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

1 2.5 3.5 10 400 7C100M40-R D 6.8 — —<br />

1 2.5 3.7 10 400 7C100M40-R D 6.8 —<br />

X2<br />

—<br />

LAMP<br />

LAMP<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

1 2.5 3.7 10 400 7C100M40-R D 6.8 — — C/D/<br />

D/D<br />

C/<br />

1 2.5 3.7 10 400 7C100M40-R D 7.0 — —<br />

C/D<br />

1 2.5 3.7 10 400 7C100M40-R D 7.0 — —<br />

1 2.3 3.5 11 370 7C110M40 D 7.0 LI533-H4 2<br />

1 2.3 3.5 11 370 7C110M40 D 7.0 LI533-H4 2<br />

206 .5 275 2 M 1 2.3 3.5 11 370 7C110M40 D 7.0 LI533-H4 2 C<br />

3 1.7 3.5 17 400 7C170P40 D 12.5 LI534-H5 20<br />

LAMP<br />

C<br />

D<br />

C/D/<br />

D/D<br />

C/<br />

C/D<br />

C/C/<br />

C/C<br />

C/<br />

C/C<br />

A<br />

A<br />

A<br />

A<br />

LAMP 2<br />

LINE V<br />

CAP<br />

CAP<br />

IGNITOR<br />

LAMP<br />

CAP<br />

COM<br />

CAP<br />

Fig. N<br />

COM<br />

Fig. H<br />

5-22<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Metal Halide<br />

NOM<br />

New<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Fig<br />

Dimensions<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

200 Watt Lamp, ANSI Code M136 (Pulse-Start)<br />

277<br />

71A5637-BP✥ Linear<br />

Reactor 218 1.3 277 4 H 10 1.0 3.1 12 280 7C120M33-R D 6.0<br />

71A5637-001D✥ HPF<br />

120/208/<br />

240/277<br />

120/<br />

277/347<br />

480/<br />

71A5642-T◆<br />

120T<br />

120/208/ 71A5692◆<br />

240/277 71A5692-001D<br />

120/<br />

277/347<br />

71A5693<br />

71A56A3<br />

71A56A2◆<br />

277/120T 71A5634-T<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Regulated<br />

Lag<br />

240<br />

240<br />

232<br />

232<br />

2.1/1.2/<br />

1.1/.9<br />

2.1/<br />

.9/.8<br />

2.0/1.2/<br />

1.0/.9<br />

2.1/<br />

.9/.7<br />

252<br />

263<br />

240<br />

235<br />

6/4/<br />

3/3<br />

5/<br />

2/2<br />

6/4/<br />

3/3<br />

6/<br />

3/2<br />

M<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Integral<br />

Ignitor<br />

M 2 1.4 3.0 15 330 7C150M33 D 8.5 LI533-H4 5<br />

M 2 1.4 3.0 15 330 7C150M33 D 8.5 LI533-H4 5<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

1 2.5 3.6 15 330 7C150M33 D 8.0 LI533-H4 2<br />

M 1 2.5 3.6 15 330 7C150M33 D 8.0 LI533-H4 2<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

2 A<br />

232 .5 240 2 M 1 2.5 3.6 15 330 7C150M33 D 8.0 LI533-H4 2 B<br />

244 .9 305 3 N 3 2.0 3.7 17 400 7C170P40 D 8.0 LI534-H5 2 A<br />

A/A/<br />

A/A<br />

A/<br />

A/A<br />

A/B/<br />

A/A<br />

C/<br />

A/A<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

71A5637-001D kits also include welded angle bracket. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-540D includes core & coil with welded angle bracket and dry-film capacitor<br />

(available for 71A5637-B only).<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA and Regulated Lag circuits, Figure is operating current. For Linear<br />

Reactor circuits, Figure is highest of starting, operating and open circuit currents<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />

ignitor model shown for use within fixtures. If a Long Range ignitor is<br />

required for remote mounting, specify on order. See pages 5-50 to 5-53 for<br />

additional information.<br />

✥ Includes auto-reset thermal protection<br />

◆ Compact 3 x 4 core design.<br />

A<br />

#10 thru-bolts<br />

B<br />

NOM Certified ballast available for Mexican<br />

MAX.<br />

and Central American markets.<br />

B<br />

MAX.<br />

A<br />

2 13 /16"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

3 7 /8"<br />

4 3 /8" 4 3 /4"<br />

4 1 /4"<br />

4 Holes cleared for<br />

Fig. 2<br />

(4 1 /4" x 4 3 /4" core)<br />

31<br />

Suffix-510D provides<br />

weldedon<br />

mounting<br />

foot bracket.<br />

B<br />

MAX.<br />

A<br />

3.75<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

4.06<br />

4.50 Fig. 10<br />

(4 1 /2" x 3 3 /4 Reactor Core )<br />

Bracket Detail<br />

(Fig. 10)<br />

Suffix-540D provides<br />

welded angle bracket<br />

to allow specific Linear<br />

Reactor ballasts to<br />

mount in 400-watt fixtures<br />

designed for<br />

standard CWA ballasts<br />

without brackets<br />

(Figure 2).<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

2 7 /16"<br />

3 1 /2" 3 15 /16"<br />

Fig. 1<br />

(3" x 4" core)<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

3 7.8 2.75 6.13 0.25<br />

2, 10 6.5 1.25 5.75 0.28<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-23


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Metal Halide<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

250 Watt Lamp, ANSI Code M58 or H37<br />

120 71A5700<br />

2.5<br />

CWA 295<br />

277 71A5730<br />

1.1<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

300<br />

300<br />

Fuse<br />

Rating<br />

(Amps)<br />

8<br />

3<br />

Wiring<br />

Dia<br />

A<br />

Dimensions<br />

Fig A B<br />

1.5 3.0<br />

2<br />

1.5 3.0<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

15 400 7C150P40-R D<br />

Total<br />

Weight<br />

(Ibs)<br />

9.0<br />

9.0<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

— —<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

A<br />

A<br />

480 71A5740<br />

71A5740-001D<br />

480/120T 71A5740-T<br />

CWA<br />

CWA<br />

295<br />

295<br />

.7<br />

.7<br />

315<br />

315<br />

2<br />

2<br />

A<br />

A<br />

2<br />

2<br />

1.7<br />

1.7<br />

3.1<br />

3.1<br />

15<br />

15<br />

400<br />

400<br />

7C150P40-R<br />

7C150P40-R<br />

D<br />

D<br />

10.0<br />

10.0<br />

—<br />

—<br />

—<br />

—<br />

B<br />

B<br />

120/277 71A5780 CWA 295 2.5/1.1 300 8/3 A 2 1.5 3.0 15 400 7C150P40-R D 9.0 — — A/A<br />

NOM<br />

127/220 71A57H0 CWA 295 2.6/1.5 300 8/5 A 2 1.5 3.0 15 400 7C150P40-R D 9.0 — — A/B<br />

NOM<br />

120/208/<br />

240/277 71A5790 CWA 295 2.5/1.4<br />

1.3/1.1<br />

300<br />

8/5/<br />

5/3<br />

A<br />

2 1.5 3.0 15 400 7C150P40-R D 9.0 — — A/A/<br />

B/A<br />

120/208/<br />

240/277 71A5770-001D CWA 295 2.5/1.4<br />

1.3/1.1<br />

120/208/<br />

240/277/<br />

480<br />

71A5750<br />

71A5750-001D<br />

CWA 290<br />

2.6/1.5/<br />

1.4/1.1/<br />

.7<br />

120/<br />

277/347 71A57A0 CWA 295 2.5/<br />

1.1/.9<br />

300<br />

315<br />

315<br />

8/5/<br />

5/3<br />

8/5/<br />

5/3/<br />

2<br />

8/<br />

3/3<br />

A<br />

A<br />

A<br />

2 1.5 3.0 15 400 7C150P40-R D 9.0 — — A/A<br />

B/A<br />

2 1.6 3.1 15 400 7C150P40-R D 10.0 — — A/A/<br />

2 1.7 3.1 15 400 7C150P40-R D 10.0 — —<br />

B/A/<br />

B<br />

A/<br />

A/A<br />

120/<br />

277/347 71A57A0-001D CWA 295 2.5/<br />

1.1/.9<br />

315<br />

8/<br />

3/3<br />

A<br />

2 1.7 3.1 15 400 7C150P40-R D 10.0 — —<br />

A/<br />

A/A<br />

120<br />

277<br />

71A5701 ◆<br />

71A5731 ◆<br />

CWA<br />

294<br />

294<br />

2.6<br />

1.1<br />

300<br />

8<br />

3<br />

A<br />

1 3.0 4.2 15 400 7C150P40-R D 9.0 — —<br />

C<br />

D<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

480<br />

120/208/<br />

240/277<br />

71A5741 ◆<br />

71A5741-OO1D<br />

71A5791 ◆ CWA 294<br />

120/208/ 71A5771-001D<br />

240/277 ◆<br />

CWA 294<br />

2.6/1.5/<br />

1.3/1.1<br />

2.6/1.5/<br />

1.3/1.1<br />

120/<br />

208/240 71A57E6 CWI 295 2.6/<br />

1.5/1.3<br />

CWA 298 .7 300 2 A 1 3.0 4.2 15 400 7C150P40-R D 9.0 — — H<br />

300<br />

300<br />

310<br />

8/5/<br />

5/3<br />

8/5/<br />

5/3<br />

7/<br />

4/4<br />

A<br />

A<br />

P<br />

1 3.0 4.2 15 400 7C150P40-R D 9.0 — — C/C/<br />

D/D<br />

1 3.0 4.2 15 400 7C150P40-R D 9.0 — — C/C/<br />

D/D<br />

2 1.8 3.3 13 425 MD1300-100 O 11.0 — —<br />

E/<br />

D/D<br />

✝ Ordering information:<br />

LINE V<br />

CAP<br />

LAMP<br />

CAP<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

LINE V<br />

Refer to pages 5-5 to 5-9.<br />

LINE V<br />

LAMP<br />

LINE V<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

COM<br />

COM<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

Fig. A<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA and CWI circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor model shown for use within fixtures. If<br />

a Long Range ignitor is required for remote mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />

◆ Special compact 3 x 4 core design. Note Bench Top Rise Codes in last column.<br />

Canadian replacement/retrofit ballast kit indicated by bold type. Refer to page 5-10.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

INTEGRATED INTEGRAL<br />

IGNITOR BALLAST<br />

LINE V<br />

IGNITOR<br />

CAP<br />

COM<br />

Fig. H<br />

LINE V<br />

CAP<br />

CAP<br />

LINE V<br />

LINE V<br />

COM<br />

Fig. P<br />

LAMP<br />

LAMP 1<br />

LAMP 2<br />

LAMP<br />

LAMP<br />

5-24<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Metal Halide<br />

New<br />

NOM<br />

Input<br />

Volts<br />

120<br />

240/120T<br />

277/120T<br />

347/120T<br />

480/120T<br />

Catalog✝<br />

Number<br />

71A5704<br />

71A5724-T<br />

71A5734-T<br />

71A57B4-T<br />

71A5744-T<br />

Circuit<br />

Type<br />

Regulated<br />

Lag<br />

Watts<br />

Input<br />

298<br />

Max •<br />

Input<br />

Current<br />

2.8<br />

1.4<br />

1.2<br />

1.0<br />

.7<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

305<br />

Fuse<br />

Rating<br />

(Amps)<br />

8<br />

4<br />

3<br />

3<br />

2<br />

Wiring<br />

Dia<br />

N<br />

Fig<br />

Dimensions<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Cap Catalog<br />

Number<br />

250 Watt Lamp, ANSI Code M138 or M153 (Pulse-Start)<br />

71A5737-BP✥ Linear<br />

277<br />

Reactor 272 1.5 277 4 H 10 1.3 3.2 14 280 7C140M33-R D 6.5<br />

71A5737-001D✥ HPF<br />

120/208/ 71A5792<br />

240/277 71A5792-001D<br />

Super<br />

CWA<br />

120/<br />

277/347 71A57A2 Super<br />

CWA<br />

480/<br />

120T<br />

71A5742-T<br />

Super<br />

CWA<br />

291<br />

291<br />

2.5/1.4/<br />

1.3/1.1<br />

2.5/<br />

1.1/.9<br />

275<br />

272<br />

8/5/<br />

5/3<br />

8/<br />

3/3<br />

250 Watt Lamp, ANSI Code M80 (HQI Double Ended and Mogul Base)<br />

120/277 71A5880 HX-HPF 290 5.5/2.3 240 6 K 2 2.6 4.3 20 280 7C200P33-R D 14.0 LI522-H5 5 A/A<br />

LINE V<br />

LAMP<br />

A<br />

B<br />

Mfd<br />

Min<br />

Volt<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Integral<br />

Ignitor<br />

M 2 1.5 3.1 17 330 7C170M33 D 9.5 LI533-H4 5<br />

M 2 1.5 3.1 17 330 7C170M33 D 9.5 LI533-H4 5<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

3 2.5 4.2 16 480 MD1606-000 O 16.0 LI534-H5 20<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

5 A<br />

281 .6 272 2 M 2 1.5 3.1 17 330 7C170M33 D 9.5 LI533-H4 5 B<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

71A5737-001D kits also include welded angle bracket. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor<br />

model shown for use within fixtures. If a Long Range ignitor is required for remote<br />

mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />

• For CWA and Regulated Lag circuits, figure is operating current. For HX circuits,<br />

figure is highest of starting, operating or open circuit currents.<br />

✥ Includes auto-reset thermal protection<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

LINE V<br />

B<br />

MAX.<br />

A<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

2 7 /16"<br />

B<br />

MAX.<br />

3 1 /2" 3 15 /16"<br />

A<br />

2 13 /16"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

Fig. 1<br />

(3" x 4" core)<br />

3 7 /8"<br />

B<br />

MAX.<br />

4 3 /8" 4 3 /4"<br />

A<br />

4 1 /4"<br />

A/A/<br />

A/B<br />

A/<br />

A/A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

Fig. 2<br />

(4 1 /4" x 4 3 /4" core)<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

LINE V<br />

X3<br />

X1<br />

LINE V<br />

IGNITOR<br />

X2<br />

LAMP<br />

3.75<br />

CAP<br />

CAP<br />

CAP<br />

COM<br />

COM<br />

Fig. M<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

LINE V<br />

LINE V<br />

CAP<br />

LINE V<br />

COM<br />

LINE V<br />

COM<br />

LAMP 1<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP 2<br />

CAP<br />

CAP<br />

CAP<br />

Fig. N<br />

LAMP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

COM<br />

Fig. K<br />

LAMP<br />

LAMP<br />

3.31<br />

Suffix-510D<br />

provides<br />

welded-on<br />

mounting<br />

foot bracket.<br />

4.06<br />

4.50 Fig. 10<br />

(4 1 /2" x 3 3 /4 Reactor Core )<br />

Suffix-540D provides<br />

welded angle bracket<br />

to allow specific<br />

Linear Reactor ballasts<br />

to mount in 400-<br />

watt fixtures designed<br />

for standard CWA ballasts<br />

without brackets<br />

(Figure 2).<br />

Bracket Detail<br />

(Fig. 10)<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

2, 10 6.5 1.25 5.75 0.28<br />

3 7.8 2.75 6.13 0.25<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-25


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

New<br />

NOM<br />

Metal Halide<br />

LL<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Fig<br />

Dimensions<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

320 Watt Lamp, ANSI Code M132 or M154 (Pulse-Start)<br />

71A5837-BP✥ Linear<br />

277<br />

Reactor 342 1.9 277 5 H 10 1.7 3.8 17.5 280 7C175M33-R D 9.5<br />

71A5837-001D✥ HPF<br />

480/<br />

120T<br />

71A5842-T<br />

71A5842-001DT<br />

120/208/ 71A5892<br />

240/277 71A5892-001D<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

120/<br />

277/347 71A58A2 Super<br />

CWA<br />

Super<br />

127/220 71A58H2<br />

CWA<br />

120/208/<br />

240/270 71A5892-LL Super<br />

CWA<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

350 Watt Lamp, ANSI Code M131 (Pulse-Start)<br />

Linear<br />

71A5937-BP✥<br />

277<br />

Reactor 375 2.1 277 5 H 10 1.9 4.0 20 280 7C200P33-R D 10.0<br />

71A5937-001D✥<br />

HPF<br />

480/<br />

71A5943-T<br />

120T<br />

120/208/ 71A5993<br />

240/277 71A5993-001D<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

120/<br />

277/347 71A59A3 Super<br />

CWA<br />

277/<br />

120T<br />

71A5934-T<br />

Regulated<br />

Lag<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Integral<br />

Ignitor<br />

Integral<br />

Ignitor<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

15 A<br />

368 .8 270 5 M 2 1.8 3.7 21 345 7C210P34-R D 11.0 LI533-H4 2 D<br />

368<br />

368<br />

3.3/1.9/<br />

1.7/1.4<br />

3.3/<br />

1.4/1.1<br />

270<br />

270<br />

8/6/<br />

5/3<br />

8/<br />

4/3<br />

M 2 1.8 3.7 21 345 7C210P34-R D 11.0 LI533-H4<br />

M 2 1.8 3.7 21 345 7C210P34-R D 11.0 LI533-H4 2<br />

365 3.0/1.7 270 8/6 M 2 1.8 3.7 21 340 7C210P34-R D 11.0 LI533-H4 2 B/B<br />

350<br />

400<br />

3.0/1.7/<br />

1.5/1.3<br />

3.4/2.0/<br />

1.7/1.5<br />

275<br />

270<br />

8/6/<br />

5/3<br />

10/7/<br />

5/5<br />

M<br />

M<br />

2 2.3 4.1 21 345 7C210P34-R D 14.5 LI533-H4 2<br />

2 1.8 3.7 22.5 345 7C225P34 D 11.0 LI533-H4 2<br />

2<br />

B/B/<br />

B/B<br />

C/<br />

C/C<br />

A/A/<br />

A/A<br />

15 A<br />

400 .9 275 3 M 2 1.8 3.7 22.5 345 7C225P34 D 11.0 LI533-H4 2 D<br />

400<br />

3.4/<br />

1.5/1.2<br />

275<br />

10/<br />

5/3<br />

M<br />

2 1.8 3.7 22.5 345 7C225P34 D 11.0 LI533-H4 2<br />

403 1.5 280 4 N 3 3.1 4.8 21 480 MD2100-030 O 21.0 LI533-H4 20 B<br />

D/C/<br />

C/C<br />

D/<br />

C/C<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

71A5837-001D and 71A5937-001D kits also include welded angle bracket.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-540D includes core & coil with welded angle bracket and dry-film capacitor<br />

(Available for 71A5837-B, 71A5937-B only)<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />

ignitor model shown for use within fixtures. If a Long Range ignitor is<br />

required for remote mounting, specify on order. See pages 5-50 to 5-53<br />

for additional information.<br />

• For CWA circuits, figure is operating current. For Linear Reactor circuits,<br />

figure is highest starting, operating, or open circuit currents.<br />

✥ Includes auto-reset thermal protection<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

LL Special High Efficiency/Low<br />

LINE V<br />

CAP<br />

LAMP<br />

CAP<br />

Loss Magnetic Ballast<br />

LINE V<br />

LINE V<br />

LINE V<br />

LAMP<br />

CAP<br />

LINE V<br />

3 7 /8"<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

B<br />

MAX.<br />

IGNITOR<br />

4 3 /8" 4 3 /4"<br />

INTEGRATED INTEGRAL<br />

IGNITOR BALLAST<br />

A<br />

LAMP<br />

CAP<br />

4 1 /4"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

Fig. Fig. 2 2<br />

(4(4¹₄”x 1 /4" x 4 3 4³₄” /4" core)<br />

Fig. P<br />

CAP<br />

LAMP<br />

LAMP 1<br />

LAMP 2<br />

LAMP<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

CAP<br />

CAP<br />

COM<br />

LAMP 1<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP 2<br />

CAP<br />

LAMP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

CAP<br />

COM<br />

Fig. M<br />

LAMP<br />

LAMP<br />

COM<br />

CAP<br />

COM<br />

Fig. A<br />

COM<br />

Fig. H<br />

COM<br />

CAP<br />

Fig. N<br />

5-26<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Metal Halide<br />

NOM<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

400 Watt Lamp, ANSI Code M59 or H33<br />

277 71A6037-B<br />

71A6037-001D<br />

120<br />

277<br />

480<br />

480/120T<br />

71A6001<br />

71A6031<br />

71A6041<br />

71A6041-001D<br />

71A6041-T<br />

Linear<br />

Reactor<br />

HPF<br />

CWA 458<br />

CWA<br />

CWA<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Fig<br />

Dimensions<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

425 2.1 277 5 H 10 1.6 3.8 20 300 7C200P33-R D 9.0<br />

462<br />

462<br />

4.0<br />

1.7<br />

1.0<br />

1.0<br />

300<br />

300<br />

300<br />

10<br />

5<br />

4<br />

4<br />

A<br />

A<br />

A<br />

2<br />

2<br />

2<br />

2.0<br />

2.0<br />

2.0<br />

2.0<br />

3.8<br />

3.8<br />

4.0<br />

4.0<br />

24 400 7C240P40-R D<br />

24<br />

24<br />

400<br />

400<br />

7C240P40-R<br />

7C240P40-R<br />

D<br />

D<br />

11.5<br />

11.5<br />

12.0<br />

12.0<br />

Ignitor<br />

(Page 5-50 to 5-54)<br />

Part<br />

Number<br />

Integral<br />

Ignitor<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

— —<br />

—<br />

—<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

2 A<br />

—<br />

—<br />

D<br />

E<br />

E<br />

E<br />

120/277 71A6081 CWA 458 4.0/1.7 300 10/5 A 2 2.0 3.9 24 400 7C240P40-R D 11.5 — — D/E<br />

NOM<br />

127/220 71A60H1 CWA 458 3.9/2.2 300 10/7 A 2 2.0 3.8 24 400 7C240P40-R D 11.5 — — D/D<br />

NOM<br />

120/208/<br />

240/277 71A6091 CWA 458 4.0/2.3/<br />

2.0/1.7<br />

120/208/<br />

240/277/<br />

71A6051<br />

4.1/2.3/<br />

71A6051-001D CWA 460 2.0/1.7/<br />

1.0<br />

480<br />

120/208/<br />

240/277 71A6071-001D CWA 458 4.0/2.3/<br />

2.0/1.7<br />

300<br />

300<br />

300<br />

10/7/<br />

5/5<br />

10/7/<br />

5/5/<br />

3<br />

10/7/<br />

5/5<br />

A<br />

A<br />

A<br />

2 2.0 3.9 24 400 7C240P40-R D 11.5 — — D/E/<br />

D/E<br />

2 2.2 4.0 24 400 7C240P40-R D 14.0 — — D/C/<br />

D/C/<br />

D<br />

2 2.2 4.0 24 400 7C240P40-R D 11.5 — — D/E/<br />

D/E<br />

120/<br />

277/347 71A60A1 CWA 460 4.0/<br />

1.7/1.4<br />

300<br />

10/<br />

5/4<br />

A<br />

2 2.0 4.0 24 400 7C240P40-R D 12.0 — —<br />

D/<br />

D/D<br />

120/<br />

277/347 71A60A1-001D CWA 460 4.0/<br />

1.7/1.4<br />

300<br />

10/<br />

5/4<br />

A<br />

2 2.4 4.0 24 400 7C240P40-R D 12.0 — —<br />

D/<br />

D/D<br />

120/<br />

208/240 71A60E6 CWI 465 4.2/<br />

2.5/2.1<br />

320 10/<br />

7/5<br />

P<br />

2 2.4 4.0 20 425 MD2006-100 O 14.0 — —<br />

E/<br />

D/D<br />

277/347 71A60F6 CWI 462 1.8/1.4 325 5/3 P 2 2.4 4.0 20 425 MD2006-100 O 14.0 — — E/D<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix<br />

-001 or -001D. 71A6037-001D kit also includes welded angle<br />

bracket. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film<br />

capacitor<br />

-540D includes core & coil with welded angle bracket and dry-film<br />

capacitor. (Available for 71A6037-B only)<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled<br />

capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA and CWI circuits, figure is operating current.<br />

For Linear Reactor circuits, figure is highest of starting, operating, or<br />

open circuit currents.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

*<br />

NOM<br />

Includes copper primary/aluminum secondary coils.<br />

Certified ballast available for Mexican and Central American markets.<br />

3.31<br />

Bracket Detail<br />

(Fig. 10)<br />

Suffix-510D provides<br />

welded-on mounting<br />

foot bracket.<br />

4 Holes cleared<br />

for #10 thru-bolts<br />

B<br />

MAX.<br />

A<br />

3.75<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

4.06<br />

4.50 Fig. 10<br />

(4 1 /2" x 3 3 /4 Reactor Core )<br />

Suffix-540D provides welded angle bracket to<br />

allow specific Linear Reactor ballasts to mount<br />

in 400-watt fixtures designed for standard CWA<br />

ballasts without brackets (Figure 2).<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

2, 10 6.5 1.25 5.75 0.28<br />

3 7.8 2.75 6.13 .25<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-27


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

NOM<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

5-28<br />

Metal Halide<br />

LL<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

400 Watt Lamp, ANSI Code M135 or M155 (Pulse-Start)<br />

277<br />

480/<br />

120T<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277<br />

120/<br />

277/347<br />

120/208<br />

240<br />

Wiring<br />

Dia<br />

Fig<br />

Dimensions<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D. 71A6137-001D and<br />

71A6337-001D kits also include welded angle bracket. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-540D includes core & coil with welded angle bracket and dry-film capacitor.<br />

(Available for 71A6137-B, 71A6337-B only)<br />

-500 includes core & coil with oil-filled capacitor<br />

CAP<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 includes core & coil only (no capacitor)<br />

-610 includes core & coil with welded bracket (no capacitor)<br />

• For CWA, CWI, and Regulated Lag circuits, figure is operating current. For Linear<br />

Reactor circuits, figure is highest of starting,operating, or open circuit currents.<br />

LINE V<br />

✝✝ Each ballast requiring an ignitor iis furnished as standard with the Short Range<br />

LINE V<br />

ignitor model shown for use within fixtures. If a Long Range ignitor is required for<br />

LINE V<br />

remote mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />

LINE V<br />

✥ Includes auto-reset thermal protection<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

COM<br />

LL Special High Efficiency/Low Loss Magnetic ballast<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Cap Catalog<br />

Number<br />

450 Watt Lamp, ANSI Code M144 (Pulse-Start)<br />

277 71A6337-BP✥ Reactor<br />

Linear<br />

480 2.4 277 7 H 10 1.9 4.0 22.5 280 7C225P30-R D 9.5<br />

HPF<br />

480/<br />

120T<br />

120/208/<br />

240/277<br />

120/<br />

277/347<br />

277/<br />

120T<br />

71A6092<br />

71A6092-001D<br />

71A60A2<br />

71A6004<br />

71A6034-T<br />

71A60B4-T<br />

71A6044-T<br />

71A60E4-T<br />

71A6343-T<br />

71A6393<br />

71A63A3<br />

71A6334-T<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Regulated<br />

Lag<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Regulated<br />

Lag<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

Min<br />

Volt<br />

LINE V<br />

COM<br />

INTEGRAL<br />

INTEGRATED<br />

IGNITOR BALLAST<br />

IGNITOR BALLAST<br />

IGNITOR<br />

Fig. H<br />

LAMP 1<br />

X3<br />

LAMP 2<br />

CAP<br />

CAP<br />

X1<br />

X2<br />

CAP<br />

Fig. N<br />

IGNITOR<br />

LAMP<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

LAMP<br />

LAMP<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Integral<br />

Ignitor<br />

LAMP 1<br />

CAP<br />

Fig. V<br />

CAP<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

452 1.0 270 3 M 2 2.0 3.8 26 330 7C260P33-R D 12.0 LI533-H4 10 D<br />

452<br />

450<br />

465<br />

3.8/2.2/<br />

1.9/1.7<br />

3.8/<br />

1.7/1.4<br />

265<br />

270<br />

10/7/<br />

5/5<br />

10/<br />

5/4<br />

400 Watt Lamp, ANSI Code M128 or M135 or M155 (Pulse-Start)<br />

4.0<br />

10<br />

Regulated 1.7<br />

5<br />

Lag 465 1.4 315 4 N 3<br />

1.0<br />

4<br />

120<br />

277/120T<br />

347/120T<br />

480/120T<br />

208/<br />

240/120T<br />

71A6137-BP✥ Linear<br />

Reactor<br />

71A6137-001D✥ HPF<br />

Super<br />

71A6042-T<br />

CWA<br />

71A6092-LL<br />

71A61E6<br />

Super<br />

CWI<br />

425 2.1 277 5 H 10 1.6 3.8 20 280 7C200P33-R D 9.0<br />

434<br />

455<br />

3.8/2.2/<br />

1.9/1.7<br />

4.2/2.4/<br />

2.1<br />

2.3/2.0<br />

265<br />

265<br />

315<br />

10/6/<br />

5/5<br />

10/7<br />

5<br />

6/5<br />

M<br />

M<br />

M<br />

V<br />

N<br />

2 1.8 3.7 26 330 7C260P33-R D 11.0 LI533-H4 10<br />

2 2.3 4.1 26 330 7C260P33-R D 14.5 LI533-H4 2<br />

2 1.8 3.7 26 330 7C260P33-R D 11.0 LI533-H4 10<br />

3<br />

3.8<br />

3.8<br />

5.5<br />

5.5<br />

21<br />

21<br />

X3<br />

IGNITOR<br />

X1<br />

X2<br />

LAMP 2<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

5 A<br />

514 1.1 267 3 M 2 2.4 4.2 26.5 360 7C265P40-R D 14 LI533-H4 5 D<br />

508<br />

4.3/2.5/ 10/8/<br />

257<br />

2.2/1.9<br />

5/5<br />

M 2 2.3 3.9 26.5 360 7C265P40-R D 13.5 LI533-H4 5<br />

505<br />

4.3/<br />

10/<br />

268<br />

1.9/1.5<br />

5/4<br />

M 2 2.4 4.2 26.5 360 7C265P40-R D 14 LI533-H4 5<br />

530 2.0 310 5 N 3 4.0 5.9 21 525 MD2100-030 O 27 LI534-H5 2 B<br />

500<br />

500<br />

MD2100-030<br />

MD2100-030<br />

Integral<br />

Ignitor<br />

2 2.2 3.8 26 330 7C260P33-R D 13.0 LI533-H4 2<br />

O<br />

O<br />

26.0<br />

26.0<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

LI534-H5<br />

LI534-H5<br />

CAP<br />

CAP<br />

Fig. M<br />

X3<br />

COM<br />

10 A<br />

10<br />

10<br />

X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

D/C/<br />

D/D<br />

A/A/<br />

A/A<br />

C/<br />

C/C<br />

E/C/<br />

C<br />

A<br />

A<br />

A<br />

A<br />

A/A<br />

C/C/<br />

C/C<br />

D/<br />

D/D<br />

LAMP<br />

LAMP


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Metal Halide<br />

New<br />

New<br />

New<br />

New<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

120/<br />

208/240<br />

277/<br />

347/480<br />

277/<br />

347/480/<br />

120T<br />

120/208/<br />

240/277<br />

347/480/<br />

120T<br />

120/<br />

208/240<br />

277/<br />

347/480<br />

71A64F2<br />

71A64F2-001D<br />

Super<br />

CWA<br />

Cap Catalog<br />

Number<br />

3.0/<br />

8/<br />

818 355<br />

M 8 2.3 4.3 28 400 7C280S40 D 17.0 LI573-H5 15<br />

2.5/1.7<br />

7/5<br />

7.8/4.3 20/10/<br />

940 415<br />

M 2 3.0 5.0 21 480<br />

3.9/3.4<br />

MD2100-030 O 17.5 LI572-H5 ★ 5<br />

10/8<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 includes core & coil only (no capacitor)<br />

-610 includes core & coil with welded bracket (no capacitor)<br />

• For CWA circuits, figure is operating current.<br />

★ Equipped with an auto-reset thermal protector to prevent ignitor from<br />

overheating in the event of lamp failure.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with<br />

the Short Range ignitor model shown for use within fixtures.<br />

N If a Long Range ignitor is required for remote mounting, specify<br />

on order. See pages 5-50 to 5-53 for additional information.<br />

Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />

Refer to page 5-3 for additional information.<br />

♦ Special Compact 4-1/4 x 4-3/4 core design<br />

3.31<br />

Input<br />

Volts<br />

B<br />

MAX.<br />

Catalog✝<br />

Number<br />

71A64E2<br />

71A64F2-T<br />

A<br />

3.75<br />

Circuit<br />

Type<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Watts<br />

Input<br />

4 Holes cleared cleared for for #10<br />

#6 thru-bolts<br />

thru-bolts<br />

4.06<br />

4.50 Fig. 10<br />

(4 1 /2" x 3 3 /4 Reactor Core )<br />

Max•<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

750 Watt Lamp, ANSI Code M149 (Pulse-Start)<br />

71A6490♦<br />

71A64F0-T♦<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

7.0/<br />

20/<br />

812 355<br />

M 8 2.2 4.3 28 400 7C280S40 D 17.0 LI573-H5 15<br />

4.0/3.5 10/10<br />

3.0/<br />

8/<br />

818 355<br />

M 8 2.3 4.3 28 400 7C280S40 D 17.0 LI573-H5 15<br />

2.5/1.7<br />

7/5<br />

71A86E5 CWA 850<br />

7.2/<br />

20/<br />

235<br />

4.1/3.6 10/10<br />

M 8a 3.2 5.3 75 280 7C750S28R D 25.0 LI561-H5 5<br />

71A86F5 CWA 850<br />

3.1/<br />

10/<br />

235<br />

2.5/1.8<br />

10/5<br />

M 8a 3.2 5.1 75 280 7C750S28R D 25.0 LI561-H5 5<br />

875 Watt Lamp, ANSI Code Unassigned (Venture pulse-start lamp)<br />

120/208/<br />

Super<br />

240/277<br />

71A6498♦ CWA<br />

347/480/<br />

Super<br />

120T<br />

71A64F8-T♦ CWA<br />

945 2.8/2.0 415 7/5 M 2 3.0 5.0 21 480 MD2100-030 O 17.5 LI572-H5 ★ 5 E/E<br />

Suffix-510D provides<br />

welded-on mounting<br />

foot bracket.<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig<br />

A<br />

B<br />

3 7 /8"<br />

B<br />

MAX.<br />

Suffix-540D provides welded<br />

angle bracket to allow specific<br />

Linear Reactor ballasts to<br />

mount in 400-watt fixtures<br />

designed for standard CWA<br />

ballasts without brackets<br />

(Figure 2).<br />

Bracket Detail<br />

(Fig. 10)<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

4 3 /8" 4 3 /4"<br />

A<br />

4 1 /4"<br />

Dry<br />

or<br />

Oil<br />

44 Holes Holes cleared cleared for for #10<br />

#10 thru-bolts<br />

Fig. 2<br />

(4¹₄”x Fig. 4³₄” 2 core)<br />

(4 1 /4" x 4 3 /4" core)<br />

Total<br />

Weight<br />

(Ibs)<br />

B<br />

MAX.<br />

3 7 /8"<br />

4 1 /4"<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

7.0/4.0/ 20/10/<br />

820 340<br />

M 2 3.0 4.9 28 400 7C280S40 D 17.5 LI573-H5 10<br />

3.5/3.0 10/10<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

820 2.5/1.7 340 7/5 M 2 3.0 4.9 28 400 7C280S40 D 17.5 LI573-H5 10 E/E<br />

750 Watt Lamp, Retrofit for 750 Watt HPS, ANSI Code S111 (Pulse-Start)<br />

E/<br />

E/E<br />

4 3 /8"<br />

5 3 /8" 6 " Fig 8, 8A<br />

Fig. 8<br />

(4 1 /4" x 6" core)<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

2, 10 6.5 1.25 5.75 0.28<br />

3, 8 7.8 2.75 6.13 0.25<br />

8a 7.8 4.50 6.75 0.31<br />

A<br />

U.L. Bench Top<br />

Rise Code 1029<br />

(Pg 5-3)<br />

ADVANCE<br />

Class H<br />

Class N<br />

(180°C)<br />

(200°C)<br />

D/<br />

C/D<br />

E/<br />

E/E<br />

D/D/<br />

D/D<br />

B/<br />

C/C<br />

E/<br />

D/D<br />

E/E/<br />

E/E<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

A/A<br />

A/A<br />

A/A<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

A/A/<br />

A/A<br />

A/A<br />

8 Holes cleared for<br />

#10 thru-bolts<br />

(4 1 /4” x 6” core)<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-29


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Metal Halide<br />

New<br />

N<br />

NOM<br />

N<br />

NOM<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

NOM<br />

N<br />

Input<br />

Volts<br />

Cap Catalog<br />

Number<br />

1000 Watt Lamp, ANSI Code M47 or H36<br />

120<br />

220<br />

277<br />

71A6502<br />

71A65J2<br />

71A6532<br />

CWA 1080<br />

9.0 9.0<br />

4.95.2<br />

3.94.9<br />

430<br />

20<br />

12<br />

10<br />

A 8 2.6 4.5 24 480 MD2409-100 O 21.0 — —<br />

480 71A6542<br />

71A6542-001<br />

CWA 1080 2.2 430 6 A 8 2.6 4.5 24 480 MD2409-100 O 21.0 — — D<br />

480/120T 71A6542-T CWA 1080 2.2 430 6 A 8 2.6 4.5 24 480 MD2409-100 O 21.0 — — D<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277/<br />

480<br />

120/<br />

277/347<br />

120/<br />

277/347<br />

120/208/<br />

240/277<br />

347/480/<br />

120T<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

71A6592 CWA 1080 9.0/5.2/<br />

4.5/3.9<br />

71A6572-001 CWA 1080 9.0/5.2/<br />

4.5/3.9<br />

71A6552<br />

9.0/5.6/<br />

71A6552-001 CWA 1080 4.7/4.1/<br />

2.4<br />

9.0/<br />

71A65A2 CWA 1080<br />

3.9/3.2<br />

71A65A2-001 CWA 1080<br />

Max•<br />

Input<br />

Current<br />

9.0/<br />

3.9/3.2<br />

71A6590◆ CWA 1070 9.0/5.2/<br />

4.5/3.9<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

430<br />

430<br />

430<br />

430<br />

430<br />

415<br />

Fuse<br />

Rating<br />

(Amps)<br />

20/15/<br />

10/10<br />

20/15/<br />

10/10<br />

22/15/<br />

12/10/<br />

6<br />

20/<br />

10/8<br />

20/<br />

10/8<br />

20/15/<br />

10/10<br />

Wiring<br />

Dia<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

Dimensions<br />

Fig<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

8 2.6 4.5 24 480 MD2409-100 O 21.0 — — D/B/<br />

B/B<br />

8 2.6 4.5 24 480 MD2409-100 O 21.0 — — D/B/<br />

B/B<br />

D/D/<br />

8 3.0 4.7 24 480 MD2409-100 O 22.0 — — D/C<br />

C<br />

8 2.8 4.5 24 480 MD2409-100 O 21.0 — —<br />

D/<br />

C/C<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

8 2.8 4.5 24 480 MD2409-100 O 21.0 — —<br />

C<br />

B<br />

B<br />

D/<br />

C/C<br />

2 3.4 5.3 24 480 MD2409-100 O 19.0 — — D/D/<br />

D/D<br />

71A65F0-T◆ CWA 1070 3.1/2.2 415 8/6 A 2 3.4 5.3 24 480 MD2409-100 O 19.0 — — D/D<br />

U.L. Bench Top<br />

Rise Code 1029<br />

(Pg 5-3)<br />

ADVANCE<br />

Class H<br />

Class N<br />

(180°C)<br />

(200°C)<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A/A/<br />

A/A<br />

A/A/<br />

A/A<br />

A/A/<br />

A/A<br />

A<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

A/A/<br />

A/A<br />

A/A<br />

N<br />

208/240<br />

120T<br />

7C400P30-R<br />

71A65E6-T CWI 1080 5.3/4.8 440 15/12 P 8 3.5 5.3 20 560<br />

D 25.0 — — C/D<br />

(Two in Series)<br />

A/A<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

New<br />

New<br />

N<br />

N<br />

N<br />

N<br />

1000 Watt Lamp, ANSI Code M141 (Pulse-Start)<br />

120/208/<br />

240/277<br />

347/480/<br />

120T<br />

120/208/<br />

240/277<br />

347/480/<br />

120T<br />

71A6593<br />

71A65F3-T<br />

71A6591◆<br />

71A65F1-T◆<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

Super<br />

CWA<br />

9.0/5.2/ 20/15/<br />

1080 430<br />

M 8 2.8 4.5 24 480 MD2409-000 O 21.0 LI571-H5 ★ 5<br />

4.5/3.9 10/10<br />

1075 3.2/2.4 430 8/6 M 8 2.8 4.5 24 440 MD2409-000 O 21.0 LI571-H5 ★ 5 D/D<br />

9.0/5.2/ 20/15/<br />

1070 415<br />

M 2 3.4 5.3 24 480 MD2409-000 O 19.0 LI572-H5 ★ 5<br />

4.5/3.9 10/10<br />

1070 3.1/2.2 415 8/6 M 2 3.4 5.3 24 480 MD2409-000 O 19.0 LI572-H5 ★ 5 D/D<br />

D/B/<br />

B/B<br />

D/D/<br />

D/D<br />

A/A/<br />

A/A<br />

A/A<br />

A/A/<br />

A/A<br />

A/A<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

★ Equipped with an auto-reset thermal protector to prevent ignitor from<br />

overheating in the event of lamp failure.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor<br />

model shown for use within fixtures. If a Long Range ignitor is required for remote<br />

mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />

• For CWA and CWI circuits, figure is operating current.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />

Refer to page 5-3 for additional information.<br />

◆ Special compact 4-1/4 x 4-3/4 core design.<br />

Certified ballast available for Mexican and Central American markets.<br />

NOM<br />

5-30<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Metal Halide<br />

N<br />

N<br />

N<br />

NOM<br />

N<br />

N<br />

N<br />

Input<br />

Volts<br />

1500 Watt Lamp, ANSI Code M48<br />

120<br />

220<br />

277<br />

480<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277<br />

120/<br />

277/347<br />

120/<br />

277/347<br />

Catalog✝<br />

Number<br />

71A6702<br />

71A67J2<br />

71A6732<br />

71A6742<br />

71A6742-001<br />

Circuit<br />

Type<br />

CWA<br />

Watts<br />

Input<br />

1605<br />

1605<br />

1605<br />

13.5<br />

7.4<br />

5.9<br />

71A6792 CWA 1605 13.5/7.8/<br />

6.8/5.9<br />

71A6772-001 CWA 1605 13.5/7.8/<br />

6.8/5.9<br />

71A67A2 CWA 1615<br />

71A67A2-001 CWA 1615<br />

Max•<br />

Input<br />

Current<br />

13.5/<br />

5.9/4.8<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor model<br />

shown for use within fixtures. If a Long Range ignitor is required for remote mounting,<br />

specify on order. See pages 5-50 to 5-53 for additional information.<br />

Canadian replacement/retrofit ballast kit indicated by bold type. Refer to page 5-10.<br />

★ Equipped with an auto-reset thermal protector to prevent ignitor from overheating in the<br />

event of lamp failure.<br />

N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />

Refer to page 5-3 for additional information.<br />

450<br />

450<br />

450<br />

450<br />

30<br />

25<br />

15<br />

30/25/<br />

20/15<br />

30/25/<br />

20/15<br />

30/<br />

15/15<br />

A<br />

B<br />

MAX.<br />

3 7 /8"<br />

4 1 /4"<br />

4 3 /8"<br />

5 3 /8" 6 "<br />

A<br />

8 Holes cleared for<br />

#10 thru-bolts<br />

Fig. 8, 88a<br />

(4 1 /4" x 6" core)<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

8a 4.0 6.0 32 525 MD3202-100 O 29.0 — —<br />

CWA 1625 3.4 450 10 A 8a 4.2 6.2 32 525 MD3202-100 O 31.0 — — E<br />

13.5/<br />

5.9/4.8<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

450<br />

Fuse<br />

Rating<br />

(Amps)<br />

30/<br />

15/15<br />

A<br />

A<br />

A<br />

A<br />

Dimensions<br />

Fig<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

8a 4.1 6.1 32 525 MD3202-100 O 30.0 — — G/E/<br />

E/G<br />

8a 4.1 6.1 32 525 MD3202-100 O 30.0 — — G/E/<br />

E/G<br />

8a 4.1 6.1 32 525 MD3202-100 O 30.0 — —<br />

8a 4.1 6.1 32 525 MD3202-100 O 30.0 — —<br />

1650 Watt Lamp, ANSI Code M112<br />

120/208/<br />

71A6890 CWA 1770 16.0/9.3/ 40/25/<br />

2 Capacitor Set:<br />

465<br />

A 8a 4.4 6.5 34 550<br />

— — H/G<br />

N 240/277<br />

8.0/7.0 20/18<br />

MD1701-200 32.0<br />

G/H<br />

(2) 17 MFD Caps<br />

O<br />

N 347/480 71A68F0 CWA 1770 5.5/4.0 465 15/10 A 8a 4.4 6.5 34 550 [ Connected in Parallel]<br />

32.0 — — I/J<br />

2000 Watt Lamp, ANSI Code M134<br />

N 208/220 71A69H0<br />

CWA 2140 10.5/10.0<br />

2 Capacitor Set:<br />

30/25<br />

43 540<br />

465<br />

8a 4.5 6.0 LI571-H5 ★ I/I<br />

M MD2602-030 and O 43.0<br />

5<br />

MD1701-100<br />

N 240/277 71A69EO<br />

9.0/8.0 25/20<br />

43 540<br />

J/J<br />

Connected in Parallel<br />

3 7 /8"<br />

B<br />

MAX.<br />

4 3 /8" 4 3 /4"<br />

A<br />

4 1 /4"<br />

44 Holes Holes cleared cleared for for #10<br />

#10 thru-bolts<br />

Fig. 2<br />

(4¹₄”x Fig. 4³₄” 2 core)<br />

(4 1 /4" x 4 3 /4" core)<br />

Wiring<br />

Dia<br />

A<br />

B<br />

Mfd<br />

Min<br />

Volt<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

U.L. Bench Top<br />

Rise Code 1029<br />

(Pg 5-3)<br />

ADVANCE<br />

Class H<br />

Class N<br />

(180°C)<br />

(200°C)<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

2 6.5 1.25 5.75 0.28<br />

8 7.8 2.75 6.13 0.25<br />

8a 7.8 4.50 6.75 0.31<br />

F<br />

F<br />

F<br />

G/<br />

G/G<br />

G/<br />

G/G<br />

B<br />

B<br />

B<br />

A<br />

C/A/<br />

A/C<br />

C/A/<br />

A/C<br />

C/<br />

C/C<br />

C/<br />

C/C<br />

D/C<br />

C/D<br />

E/F<br />

E/E<br />

F/F<br />

NOM Certified ballast available for Mexican and Central American<br />

markets.<br />

HID • CORE & COIL<br />

METAL HALIDE<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-31


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

35 Watt Lamp, ANSI Code S76<br />

R-NPF<br />

120 71A7707<br />

46<br />

R-HPF<br />

71A7707-B R-NPF<br />

120<br />

46<br />

71A7707-001DB R-HPF<br />

1.4<br />

.8<br />

1.4<br />

.8<br />

120<br />

120<br />

3<br />

2<br />

3<br />

2<br />

G<br />

H<br />

9 .7 1.8<br />

9 .7 2.2<br />

—<br />

14<br />

—<br />

14<br />

—<br />

120<br />

—<br />

120<br />

————–<br />

7C140L12<br />

————–<br />

7C140L12<br />

—<br />

D<br />

—<br />

D<br />

1.3<br />

1.5<br />

1.3<br />

1.5<br />

LI551-H4 2 A<br />

Integral<br />

Ignitor<br />

2 A<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D(B).<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For AR, R and Hybrid circuits, figure is highest of starting, operating or open circuit<br />

currents.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor<br />

model shown for use within fixtures. If a Long Range ignitor is required for remote<br />

mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />

•• 277V operation requires the 120V reactor ballast and controller plus the 120/277V<br />

auto-transformer listed. Ballast dimensions shown in table are for the reactor ballast<br />

component only. See page 5-54 for auto-transformer specifications and dimensions.<br />

COM<br />

CAP<br />

CAP<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

LAMP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

COM<br />

LAMP<br />

Fig. K<br />

120 V<br />

HID • CORE & COIL<br />

HPS<br />

LINE V<br />

(OPTIONAL) CAP<br />

COM<br />

X3<br />

IGNITOR<br />

X2<br />

X1<br />

LAMP<br />

LAMP<br />

CAP REACTOR<br />

NEUTRAL<br />

LAMP (RED) HV<br />

LAMP<br />

3<br />

CONTROLLER<br />

4<br />

LAMP (BLUE) LV<br />

Fig. R<br />

Fig. G<br />

INTEGRAL<br />

INTEGRATED<br />

IGNITOR IGNITOR BALLAST BALLAST<br />

AUTO TRANSFORMER<br />

277V<br />

120 V<br />

LINE V<br />

LAMP<br />

CAP<br />

REACTOR<br />

3<br />

CONTROLLER<br />

CAP<br />

IGNITOR<br />

LAMP<br />

NEUTRAL/COM<br />

4<br />

COM<br />

LAMP (RED) HV<br />

LAMP<br />

LAMP (BLUE) LV<br />

Fig. H<br />

Fig. S<br />

5-32<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

HID<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

50 Watt Lamp, ANSI Code S68<br />

R-NPF<br />

120 71A7807<br />

62<br />

R-HPF<br />

71A7807-B R-NPF<br />

120<br />

62<br />

71A7807-001DB R-HPF<br />

120/277 71A7801<br />

71A7801-001D<br />

Max •<br />

Input<br />

Current<br />

1.8<br />

1.0<br />

1.8<br />

1.0<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

120<br />

120<br />

Fuse<br />

Rating<br />

(Amps)<br />

5<br />

3<br />

5<br />

3<br />

Wiring<br />

Dia<br />

G<br />

H<br />

Fig<br />

Dimensions<br />

A<br />

B<br />

9 1.0 2.3<br />

9 1.0 2.7<br />

Mfd<br />

—<br />

20<br />

—<br />

20<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

—<br />

120<br />

—<br />

120<br />

Cap Catalog<br />

Number<br />

————–<br />

7C200M12<br />

————–<br />

7C200M12<br />

Dry<br />

or<br />

Oil<br />

—<br />

D<br />

—<br />

D<br />

Total<br />

Weight<br />

(Ibs)<br />

1.8<br />

2.0<br />

1.8<br />

2.0<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

LI551-H4 2 A<br />

Integral<br />

Ignitor<br />

2 A<br />

HX-HPF 66 1.0/.5 125 3/1 K 1 1.0 2.2 5 300 7C050L33 D 3.5 LI551-H4 2 A/A<br />

50 Watt Lamp, ANSI Code S104 (White SON - Philips) (Minimum Starting Temperature –20°F or –30°C)<br />

120 71A7805<br />

Hybrid<br />

<strong>Electronic</strong><br />

68 1.3 120 3 R 9 1.3 2.3 28 120 7C280M12 D 4.0<br />

6C050<br />

Controller<br />

2 A<br />

120/277<br />

••<br />

71A7805(120V)<br />

+<br />

71A9847(120/277V<br />

Auto transformer)<br />

Hybrid<br />

<strong>Electronic</strong><br />

AR<br />

72 0.6 120 3/1<br />

S<br />

9<br />

(2pcs)<br />

6C050<br />

1.3 2.3 28 120 7C280M12 D 8.0 2 A/A<br />

Controller<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D(B).<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For AR, HX, R, and Hybrid circuits, figure is highest of starting, operating<br />

or open circuit currents.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />

ignitor model shown for use within fixtures. If a Long Range ignitor is<br />

required for remote mounting, specify on order. Instant Restrike ignitor also<br />

available (71A7807 and 71A7801 only). See pages 5-50 to 5-53 for additional<br />

information.<br />

• • 277V operation requires the 120V reactor ballast and controller plus the<br />

120/277V auto-transformer listed. Ballast dimensions shown in table are for<br />

the reactor ballast component only. See page 5-54 for auto-transformer<br />

specifications and dimensions.<br />

4 3 /16"<br />

p. 80 o C<br />

rounded.<br />

3 1 /16"<br />

Rectangular Case<br />

White SON Controller<br />

1 11 /16"<br />

HID • CORE & COIL<br />

HPS<br />

B<br />

MAX.<br />

A<br />

2 3 /16"<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

B<br />

MAX.<br />

A<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

2 13 /16"<br />

1 3 /4"<br />

2 3 /16"<br />

2 5 /8" Fig. 9<br />

(2 5 /8" x 2 3 /16 Reactor Core )<br />

2 7 /16"<br />

3 1 /2" 3 15 /16"<br />

Fig. 1<br />

(3" x 4" core)<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

9 4.0 0.75 3.50 0.28<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-33


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weigh<br />

t (Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

70 Watt Lamp, ANSI Code S62<br />

NOM<br />

120 71A7907<br />

R-NPF<br />

R-HPF<br />

86<br />

2.1<br />

1.3<br />

120<br />

8<br />

3<br />

G<br />

9 1.3 2.5<br />

—<br />

28<br />

—<br />

120<br />

————–<br />

7C280M12<br />

—<br />

D<br />

2.0 LI551-H4 2 A<br />

120<br />

71A7907-B<br />

71A7907-001DB<br />

R-NPF<br />

R-HPF<br />

86<br />

2.1<br />

1.3<br />

120<br />

8<br />

3<br />

H<br />

9 1.3 2.9<br />

—<br />

28<br />

—<br />

120<br />

————–<br />

7C280M12<br />

—<br />

D<br />

2.0<br />

Integral<br />

Ignitor<br />

2 A<br />

120/277<br />

220<br />

480<br />

71A7901<br />

71A79J1<br />

71A7941<br />

HX-HPF<br />

91<br />

91<br />

93<br />

1.4/.7<br />

.8<br />

.4<br />

120<br />

5/2<br />

2<br />

2<br />

K<br />

1<br />

1.5<br />

1.5<br />

1.9<br />

2.8<br />

2.8<br />

3.2<br />

7 300 7C070L33-R D<br />

5.5<br />

5.5<br />

6.5<br />

LI551-H4 2<br />

A/A<br />

A<br />

A<br />

NOM<br />

120/208/<br />

240/277 71A7991 HX-HPF 91 1.4/.9<br />

.8/.7<br />

120<br />

5/3/<br />

2/2<br />

K<br />

1 1.5 3.1 7 300 7C070L33-R D 5.5<br />

LI551-H4<br />

2<br />

B/C/<br />

B/C<br />

120/208/<br />

240/277 71A7971-001D HX-HPF 91 1.4/.9<br />

.8/.7<br />

120<br />

5/3/<br />

2/2<br />

K<br />

1 1.5 3.1 7 300 7C070L33-R D 5.5<br />

LI551-H4 2<br />

B/C/<br />

B/C<br />

120/<br />

277/347 71A79A1 HX-HPF 93 1.4/<br />

.7/.6<br />

120<br />

5/<br />

2/2<br />

K<br />

1 1.5 3.1 7 300 7C070L33-R D 5.5<br />

LI551-H4<br />

2<br />

A/<br />

B/A<br />

120/<br />

277/347<br />

71A79A1-001D HX-HPF 93<br />

1.4/<br />

.7/.6<br />

120<br />

5/<br />

2/2<br />

K<br />

1 1.5 3.1 7 300 7C070L33-R D 5.5<br />

LI551-H4 2<br />

A/<br />

B/A<br />

HID • CORE & COIL<br />

HPS<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D(B).<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor) (71A7907 Only)<br />

• For HX and R circuits, figure is highest of starting, operating or open circuit<br />

currents.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />

ignitor model shown for use within fixtures. If a Long Range ignitor is<br />

required for remote mounting, specify on order. Instant Restrike ignitor also<br />

available (excludes 71A7907-B, 71A79J1 and 71A7941).<br />

See pages 5-50 to 5-53 for additional information.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

9 4.0 0.75 3.50 0.28<br />

B<br />

MAX.<br />

A<br />

2 3 /16"<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

B<br />

MAX.<br />

A<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

2 13 /16"<br />

1 3 /4"<br />

2 3 /16"<br />

2 5 /8" Fig. 9<br />

(2 5 /8" x 2 3 /16 Reactor Core )<br />

2 7 /16"<br />

3 1 /2" 3 15 /16"<br />

Fig. 1<br />

(3" x 4" core)<br />

5-34<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

HID<br />

High Pressure Sodium<br />

NOM<br />

Input<br />

Volts<br />

127/220<br />

120/277<br />

120/<br />

208/240<br />

Catalog✝<br />

Number<br />

71A79H8<br />

71A7988<br />

120/240 71A7950<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

70 Watt Lamp, ANSI Code S62<br />

CWA 95<br />

71A79E6 CWI 95<br />

Regulated<br />

Lag<br />

Max •<br />

Input<br />

Current<br />

.8/.5<br />

.9/.4<br />

.9/<br />

.5/.5<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

105<br />

110<br />

Fuse<br />

Rating<br />

(Amps)<br />

2/2<br />

3/1<br />

3/<br />

2/2<br />

Wiring<br />

Dia<br />

M<br />

V<br />

Fig<br />

Dimensions<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Wt.<br />

(Ibs)<br />

1 1.5 2.8 28 170 7C280P30-R D 5.5<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

LI551-J4 5<br />

1 1.6 2.9 24 300 7C240P30 D 5.8 LI551-J4 2<br />

103 .9/.5 125 2.5/1 N 1 2.1 3.3 20 300 7C200P33-R D 6.3 LI551-H4 2 D/B<br />

✝ Ordering information:<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA, CWI and Regulated Lag circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />

ignitor model shown for use within fixtures. If a Long Range ignitor is<br />

required for remote mounting, specify on order. See pages 5-50 to 5-53 for<br />

additional information.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

A/D<br />

A/D<br />

C/<br />

C/D<br />

LINE V<br />

LAMP<br />

LINE V<br />

LAMP<br />

LINE V<br />

LAMP 1<br />

(OPTIONAL)<br />

COM<br />

CAP<br />

X3<br />

IGNITOR<br />

X2<br />

Fig. G<br />

X1<br />

LAMP<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

CAP<br />

CAP<br />

Fig. M<br />

X3 X1<br />

IGNITOR<br />

X2<br />

COM<br />

LAMP<br />

LINE V<br />

LINE V<br />

COM<br />

X3 X1<br />

IGNITOR<br />

X2<br />

CAP<br />

CAP<br />

LAMP 2<br />

Fig. V<br />

LAMP<br />

HID • CORE & COIL<br />

HPS<br />

INTEGRATED INTEGRAL<br />

IGNITOR BALLAST<br />

LINE V<br />

LAMP 1<br />

CAP<br />

LAMP<br />

LINE V<br />

CAP<br />

IGNITOR<br />

LAMP<br />

LAMP<br />

LINE V<br />

LINE V<br />

LINE V<br />

X3<br />

LAMP 2<br />

X1<br />

X2<br />

IGNITOR<br />

LAMP<br />

COM<br />

CAP<br />

LINE V<br />

LINE V<br />

LINE V<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

CAP<br />

LINE V<br />

COM<br />

CAP<br />

COM<br />

COM<br />

Fig. H<br />

COM<br />

CAP<br />

Fig. N<br />

Fig. K<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-35


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Wt.<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

100 Watt Lamp, ANSI Code S54<br />

120 71A8007<br />

R-NPF<br />

R-HPF<br />

115<br />

3.1<br />

1.8<br />

120<br />

10<br />

5<br />

G<br />

9 1.5 2.7<br />

—<br />

36<br />

—<br />

120<br />

————–<br />

7C360M12<br />

—<br />

D<br />

2.5<br />

2.8<br />

LI551-H4 2 A<br />

120<br />

71A8007-B<br />

71A8007-001DB<br />

R-NPF<br />

R-HPF<br />

115<br />

3.1<br />

1.8<br />

120<br />

10<br />

5<br />

H<br />

9 1.5 2.7<br />

—<br />

36<br />

—<br />

120<br />

————–<br />

7C360M12<br />

—<br />

D<br />

2.5<br />

2.8<br />

Integral<br />

Ignitor<br />

2 A/A<br />

120/277<br />

220<br />

71A8001<br />

71A80J1<br />

HX-HPF 130<br />

2.2/.9<br />

1.2<br />

120<br />

7/3<br />

3<br />

K<br />

1 2.0 3.3 10 280 7C100M33-R D 7.2 LI551-H4 2<br />

C/C<br />

B<br />

71A8041<br />

480<br />

HX-HPF 130 .6 120 3<br />

71A8041-001D K 1 2.3 3.6 10 280 7C100M33-R D 7.5 LI551-H4 2 E<br />

120/208/<br />

240/277 71A8091 HX-HPF 130 2.2/1.3/ 7/5/<br />

D/F/<br />

120<br />

K 1 2.0 3.6 10 280 7C100M33-R D 7.2 LI551-H4 2<br />

1.1/.9<br />

3/3<br />

D/D<br />

120/208/<br />

240/277 71A8071-001D HX-HPF 130 2.2/1.3/ 7/5/<br />

D/F/<br />

120<br />

K 1 2.0 3.6 10 280 7C100M33-R D 7.2 LI551-H4 2<br />

1.1/.9<br />

3/3<br />

D/D<br />

120/<br />

277/347 71A80A1 HX-HPF 130 2.2/<br />

7/<br />

C/<br />

120<br />

K 1 2.3 3.6 10 280 7C100M33-R D 7.5 LI551-H4 2<br />

.9/.7<br />

3/3<br />

C/D<br />

120/<br />

277/347 71A80A1-001D HX-HPF 130 2.2/<br />

7/<br />

C/<br />

120<br />

K 1 2.3 3.6 10 280 7C100M33-R D 7.5 LI551-H4 2<br />

.9/.7<br />

3/3<br />

C/D<br />

100 Watt Lamp, ANSI Code S105, (White SON-Philips) (Minimum Starting Temperature –20°F or –30°C)<br />

Hybrid<br />

6C100<br />

120 71A8005<br />

120 2.2 120 5 R 9 2.0 3.2 45 120 7C450P12 D 5.5<br />

2 A<br />

<strong>Electronic</strong><br />

Controller<br />

HID • CORE & COIL<br />

HPS<br />

120/277<br />

••<br />

71A8005(120V)<br />

+<br />

71A9876(120/277V<br />

Auto transformer)<br />

Hybrid<br />

<strong>Electronic</strong><br />

AR<br />

125 1.0 120 5/3<br />

9<br />

(2pcs)<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -<br />

001D(B). Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film<br />

capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor) (71A8007 Only)<br />

• For AR, HX, R and Hybrid circuits, figure is highest of starting,<br />

operating or open circuit currents.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the<br />

Short Range ignitor model shown for use within fixtures. If a Long<br />

Range ignitor is required for remote mounting, specify on order.<br />

Instant Restrike ignitor also available (excludes 71A8005, 71A8007-B,<br />

71A80J1 and 71A8041). See pages 5-50 to 5-53 for additional<br />

information.<br />

•• 277V operation requires the 120V reactor ballast and controller<br />

plus the 120/277V auto-transformer listed. Ballast dimensions<br />

shown in table are for the reactor ballast component only. See<br />

page 5-54 for auto-transformer specifications and dimensions.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

S<br />

LINE V<br />

(OPTIONAL)<br />

CAP<br />

LINE V<br />

COM<br />

2.0 3.2 45 120 7C450P12 D 9.5<br />

COM<br />

CAP<br />

IGNITOR<br />

Fig. H<br />

X3<br />

IGNITOR<br />

X2<br />

Fig. G<br />

INTEGRAL<br />

INTEGRATED<br />

IGNITOR BALLAST<br />

LAMP<br />

X1<br />

LAMP<br />

LAMP<br />

LAMP<br />

4 3 /16"<br />

COM<br />

p. 80 o C<br />

rounded.<br />

CAP<br />

3 1 /16"<br />

CAP<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

6C100<br />

Controller<br />

Fig. K<br />

LAMP<br />

X3<br />

IGNITOR<br />

X2<br />

COM<br />

1 11 /16"<br />

2 A/A<br />

X1<br />

LAMP<br />

Rectangular<br />

Case<br />

White SON<br />

Controller<br />

5-36<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

HID<br />

NOM<br />

NOM<br />

NOM LL<br />

Input<br />

Volts<br />

Catalog<br />

Number †<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

100 Watt Lamp, ANSI Code S54<br />

120/277<br />

127/220<br />

480/120T<br />

120/240<br />

120/277<br />

240/480<br />

71A8088<br />

71A80H8<br />

71A8048-T<br />

71A8050<br />

71A8080<br />

71A8060<br />

CWA 138<br />

Regulated<br />

Lag<br />

138<br />

Max •<br />

Input<br />

Current<br />

1.2/.5<br />

1.1/.7<br />

.3<br />

1.2/.6<br />

1.2/.6<br />

.6/.3<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

115<br />

120<br />

Fuse<br />

Wiring<br />

Rating<br />

Dia<br />

(Amps)<br />

3/2<br />

3/2<br />

1<br />

3/<br />

2/2<br />

3/2<br />

3/2<br />

1.5/1<br />

Dimensions<br />

Fig A B Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

High Pressure Sodium<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(lbs)<br />

Ignitor ††<br />

(Page 5-50 to 5-53)<br />

Max<br />

Dist<br />

Part<br />

To<br />

Number<br />

Lamp<br />

(ft)<br />

M 1 2.0 3.3 34 170 7C340P24 D 7.5 LI551-J4 5<br />

120/<br />

208/240 71A80EG CWI 130 1.2/<br />

.7/.6<br />

110<br />

V 1 2.1 3.4 35 170 7C350P24 D 6.8 LI551-J4 2<br />

120/240 71A8056 CWI 130 1.3/0.7 108 3/2 V 1 2.1 3.4 35 170 7C350P24 D 6.8 LI551-J4 2 C/B<br />

230 71A80J8 CWA 136 0.7 118 2 M 1 2.0 3.3 34 170 7C350P24 D 7.5 LI551-J4 5 E<br />

220/240 7180J9 CWA 124 0.6/0.6 117 2/2 M 1 2.8 4.6 34 240 7C340P24 D 10.5 LI551-J4 5 A/A<br />

✝ Ordering information:<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA, CWI and Regulated Lag circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor model shown<br />

for use within fixtures. If a Long Range ignitor is required for remote mounting, specify on order.<br />

See pages 5-50 to 5-53 for additional information.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

LL Special High Efficiency/Low Loss Magnetic ballast<br />

N 2 1.4 3.0 16 330 7C160M33 D 8.5 LI551-H4 2<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

F/F<br />

E/D<br />

E<br />

C/<br />

C/B<br />

A/A<br />

A/A<br />

A/A<br />

4 Holes cleared for<br />

120 V<br />

CAP<br />

REACTOR<br />

B<br />

MAX.<br />

A<br />

#10 thru-bolts<br />

NEUTRAL<br />

LAMP (RED) HV<br />

LAMP<br />

3<br />

CONTROLLER<br />

4<br />

LAMP (BLUE) LV<br />

Fig. R<br />

2 7 /16"<br />

3 1 /2" 3 15 /16"<br />

2 13 /16"<br />

Fig. 1<br />

(3" x 4" core)<br />

B<br />

MAX.<br />

A<br />

2 3 /16"<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

HID • CORE & COIL<br />

HPS<br />

AUTO TRANSFORMER<br />

277V<br />

120 V<br />

REACTOR<br />

CAP<br />

NEUTRAL/COM<br />

LAMP (RED) HV<br />

3<br />

4<br />

CONTROLLER<br />

LINE V<br />

LINE V<br />

LINE V<br />

LAMP 1<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

3 /4"<br />

2 3 /16"<br />

2 5 /8" Fig. 9<br />

(2 5 /8" x 2 3 /16 Reactor Core )<br />

LAMP<br />

Fig. S<br />

LAMP (BLUE) LV<br />

COM<br />

CAP<br />

Fig. V<br />

CAP<br />

LAMP 2<br />

LINE V<br />

LAMP<br />

LINE V<br />

LAMP 1<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

CAP<br />

CAP<br />

Fig. M<br />

X3 X1<br />

IGNITOR<br />

X2<br />

COM<br />

LAMP<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP 2<br />

CAP<br />

CAP<br />

CAP<br />

Fig. N<br />

LAMP<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

2 6.5 1.25 5.75 0.28<br />

9 4.0 0.75 3.50 0.28<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-37


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

150 Watt Lamp, ANSI Code S55 (55-Volt Arc Tube)<br />

120<br />

120<br />

71A8107<br />

71A8107-B<br />

71A8107-001DB<br />

R-NPF<br />

R-HPF<br />

R-NPF<br />

R-HPF<br />

170<br />

170<br />

4.5<br />

2.4<br />

4.5<br />

2.4<br />

120<br />

120<br />

15<br />

8<br />

15<br />

8<br />

G<br />

H<br />

9<br />

9<br />

2.0<br />

2.0<br />

3.3<br />

3.6<br />

—<br />

55<br />

—<br />

55<br />

—<br />

120<br />

—<br />

120<br />

––––––––<br />

7C550P12<br />

––––––––<br />

7C550P12<br />

—<br />

D<br />

—<br />

D<br />

3.5<br />

4.0<br />

3.5<br />

4.0<br />

LI551-H4<br />

Integral<br />

Ignitor<br />

2<br />

2<br />

A<br />

A<br />

120/277<br />

220<br />

277<br />

71A8102<br />

71A81J2<br />

71A8132<br />

HX-HPF 188<br />

2.8/1.3<br />

1.5<br />

1.3<br />

120<br />

10/4<br />

4<br />

4<br />

K<br />

1 2.6 3.8 14 280 7C140M33-R D 7.5 LI551-H4 2<br />

E/E<br />

C<br />

D<br />

480<br />

71A8142<br />

71A8142-001D<br />

HX-HPF 188 0.7<br />

480/120T 71A8142-T HX-HPF 188 0.7<br />

120/208/<br />

240/277 71A8192 HX-HPF 188 2.8/1.6/<br />

1.4/1.3<br />

120<br />

120<br />

120<br />

2<br />

2<br />

10/5/<br />

5/4<br />

K<br />

K<br />

K<br />

1 3.0 4.3 14 280 7C140M33-R D 9.0<br />

1 3.0 4.3 14 280 7C140M33-R D 9.0<br />

LI551-H4 2<br />

LI551-H4 2<br />

1 2.6 3.8 14 280 7C140M33-R D 7.5 LI551-H4 2<br />

E<br />

E<br />

E/D/<br />

E/D<br />

120/208/<br />

240/277 71A8172-001D HX-HPF 188 2.8/1.6/<br />

1.4/1.3<br />

120<br />

10/5/<br />

5/5<br />

K<br />

1 2.6 3.8 14 280 7C140M33-R D 7.5 LI551-H4 2<br />

E/D/<br />

E/D<br />

120/<br />

277/347 71A81A2 HX-HPF 188 2.8/<br />

1.3/.9<br />

120<br />

10/<br />

4/3<br />

K<br />

1 2.6 3.8 14 280 7C140M33-R D 7.5 LI551-H4 2<br />

D/<br />

D/D<br />

120/<br />

277/347 71A81A2-001D HX-HPF 188 2.8/<br />

1.3/.9<br />

120<br />

10/<br />

4/3<br />

K<br />

1 2.6 3.8 14 280 7C140M33-R D 7.5 LI551-H4 2<br />

D/<br />

D/D<br />

HID • CORE & COIL<br />

HPS<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D(B).<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor) (71A8107 Only)<br />

• For HX and R circuits, figure is highest of starting, operating or open circuit currents.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short Range ignitor<br />

model shown for use within fixtures. If a Long Range ignitor is required for remote<br />

mounting, specify on order. Instant Restrike ignitor also available (excludes<br />

71A8107-B, 71A81J2, 71A8132 and 71A8142). See pages 5-50 to 5-53 for<br />

additional information.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

LINE V<br />

(OPTIONAL) CAP<br />

COM<br />

CAP<br />

LINE V<br />

LINE V<br />

CAP<br />

LINE V<br />

COM<br />

LINE V<br />

COM<br />

LAMP<br />

X3<br />

X1<br />

IGNITOR<br />

X2<br />

Fig. G<br />

LAMP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

COM<br />

LAMP<br />

LAMP<br />

Fig. K<br />

INTEGRAL<br />

INTEGRATED<br />

IGNITOR BALLAST<br />

IGNITOR BALLAST<br />

LINE V<br />

LAMP<br />

CAP<br />

IGNITOR<br />

LAMP<br />

COM<br />

Fig. H<br />

5-38<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

HID<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

150 Watt Lamp, ANSI Code S55 (55-Volt Arc Tube)<br />

120/277<br />

127/220<br />

480<br />

71A8188<br />

71A81H8<br />

71A8148<br />

CWA 190<br />

1.7/.7<br />

1.6/.9<br />

.5<br />

110<br />

5/3<br />

4/2<br />

1<br />

Wiring<br />

Dia<br />

M<br />

Fig<br />

1<br />

Dimensions<br />

A<br />

2.8<br />

2.8<br />

2.5<br />

B<br />

4.1<br />

4.1<br />

3.8<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

55 170 7C550P24 D<br />

Total<br />

Weight<br />

(Ibs)<br />

8.5<br />

8.5<br />

8.0<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

LI551-J4 10<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

E/D<br />

D/C<br />

E<br />

120/<br />

208/240<br />

71A81E6 CWI 190<br />

1.7/<br />

1.1/.8<br />

105<br />

5/<br />

3/3<br />

V<br />

1 2.6 4.0 52 240 7C520P24 D 8.5 LI551-J4 2<br />

E/<br />

E/D<br />

120/240<br />

120/277<br />

240/480<br />

71A8150<br />

71A8180<br />

71A8160<br />

Regulated<br />

Lag 196<br />

1.7/.9<br />

1.7/.8<br />

.9/.4<br />

120<br />

5/3<br />

5/2<br />

3/1<br />

N<br />

2 2.0 3.5 16 400 7C160P40 D 12.0 LI551-H4 2<br />

B/B<br />

B/A<br />

B/B<br />

150 Watt Lamp, ANSI Code S56 (100-Volt Arc Tube)<br />

480 71A8146-001D CWA 188 0.5 180 2 M 1 2.5 3.8 20 280 7C200P33-R D 8.5 LI501-H4 2 B<br />

120/208/<br />

240/277 71A8196 CWA 188 1.7/1.0<br />

.9/.8<br />

120/208/<br />

240/277 71A8176-001D CWA 188 1.7/1.0<br />

.9/.8<br />

180<br />

180<br />

5/3/<br />

3/3<br />

5/3/<br />

3/3<br />

M<br />

M<br />

1 2.5 4.1 20 280 7C200P33-R D 8.5<br />

1 2.5 4.1 20 280 7C200P33-R D 8.5<br />

LI501-H4 2<br />

LI501-H4 2<br />

NOM LL 220/240 71A81J9 CWA 170 0.8/0.7 111 2/2 M 2 2.5 3.8 60 240 7C600P24 D 13.5 LI551-J4 2 A/A<br />

E/D/<br />

C/C<br />

E/D/<br />

C/C<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D. Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA, CWI and Regulated Lag circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short Range ignitor model shown<br />

for use within fixtures. If a Long Range ignitor is required for remote mounting, specify on order. See<br />

pages 5-50 to 5-53 for additional information.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

LL Special High Efficiency/Low Loss Magnetic ballast<br />

1 3 /4"<br />

B<br />

MAX.<br />

B<br />

MAX.<br />

2 3 /16"<br />

A<br />

2 3 /16"<br />

A<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

2 5 /8" Fig. 9<br />

(2 5 /8" x 2 3 /16 Reactor Core )<br />

4 1 /4"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

HID • CORE & COIL<br />

HPS<br />

4 Holes cleared for<br />

LINE V<br />

LINE V<br />

LINE V<br />

LAMP 1<br />

X3<br />

X1<br />

X2<br />

IGNITOR<br />

LAMP<br />

B<br />

MAX.<br />

A<br />

2 13 /16"<br />

#10 thru-bolts<br />

3 7 /8"<br />

4 3 /8" 4 3 /4"<br />

Fig. 2<br />

(4 1 /4" x 4 3 /4" core)<br />

LAMP 2<br />

LINE V<br />

CAP<br />

COM<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

CAP<br />

CAP<br />

Fig. N<br />

LAMP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

CAP<br />

CAP<br />

COM<br />

LAMP<br />

2 7 /16"<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

3 1 /2" 3 15 /16"<br />

LAMP 1<br />

CAP<br />

CAP<br />

Fig. 1<br />

(3" x 4" core)<br />

X3<br />

IGNITOR<br />

X1<br />

X2<br />

LAMP 2<br />

LAMP<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

2 6.5 1.25 5.75 0.28<br />

9 4.0 0.75 3.50 0.28<br />

Fig. M<br />

Fig. V<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-39


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog<br />

Number †<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Wiring<br />

Rating<br />

Dia<br />

(Amps)<br />

Dimensions<br />

Fig A B Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(lbs)<br />

Ignitor ††<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

200 Watt Lamp, ANSI Code S66<br />

71A8940<br />

480<br />

71A8940-001D<br />

120/208/<br />

240/277 71A8990 CWA 240 2.2/1.3<br />

1.1/1.0<br />

120/208/<br />

240/277 71A8970-001D CWA 240 2.2/1.3<br />

1.1/1.0<br />

CWA 240 .6 185 2 M 2 1.2 3.0 28 280 7C280P30-R D 8.5 LI501-H4 2 C<br />

185<br />

185<br />

6/4/<br />

3/3<br />

6/4/<br />

3/3<br />

M 2 1.2 3.0 28 280 7C280P30-R D 8.5 LI501-H4 2<br />

M 2 1.2 3.0 28 280 7C280P30-R D 8.5 LI501-H4 2<br />

480 71A8941 CWA 250 .6 195 2 M 1 3.0 4.2 24 280 7C240P30 D 8.5 LI501-H4 2 J<br />

120/208/<br />

240/277 71A8991 CWA 250 2.4/1.4<br />

1.2/1.0<br />

195<br />

8/5/<br />

5/3<br />

M 1 3.0 4.2 24 280 7C240P30 D 8.5 LI501-H4 2<br />

120/208/<br />

2.1/1.2<br />

6/5/<br />

C/B/B/<br />

240/277/ 71A8950 CWA 242 1.1/1.0 199<br />

M 2 1.4 3.0 28 280 7C280P30-R D 9.0 LI501-H4 2<br />

3/3/2<br />

B/B<br />

480<br />

0.6<br />

120/240 71A8954<br />

Regulated<br />

Lag<br />

255 2.2/1/1 225 6/3 N 2 2.3 3.9 18 400 7C180P40-R D 14.0 LI501-H4 2 C<br />

240/480 71A8964<br />

Regulated<br />

Lag<br />

255 1.1/.7 225 3/2 N 2 2.3 3.9 18 400 7C180P40-R D 14.0 LI501-H4 2 C<br />

E/D/<br />

D/C<br />

E/D/<br />

D/C<br />

H/G/<br />

H/I<br />

HID • CORE & COIL<br />

HPS<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA and Regulated Lag circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short Range ignitor model shown for<br />

use within fixtures. If a Long Range ignitor is required for remote mounting, specify on order. See<br />

pages 5-50 to 5-53 for additional information.<br />

◆ Special compact 3 x 4 core design. Note Bench Top Rise Codes in last column.<br />

B<br />

MAX.<br />

A<br />

4 1 /4"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

LINE V<br />

LINE V<br />

LINE V<br />

LAMP 1<br />

X3 X1<br />

X2<br />

IGNITOR<br />

LAMP<br />

B<br />

MAX.<br />

A<br />

2 13 /16"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

3 7 /8"<br />

4 3 /8" 4 3 /4"<br />

Fig. 2<br />

(4 1 /4" x 4 3 /4" core)<br />

LAMP 2<br />

LINE V<br />

CAP<br />

CAP<br />

COM<br />

CAP<br />

Fig. N<br />

2 7 /16"<br />

3 1 /2" 3 15 /16"<br />

Fig. 1<br />

(3" x 4" core)<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

CAP<br />

CAP<br />

Fig. M<br />

LAMP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

COM<br />

LAMP<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

LAMP 1<br />

X3 X1<br />

IGNITOR<br />

X2<br />

CAP<br />

CAP<br />

LAMP 2<br />

LAMP<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

2 6.5 1.25 5.75 0.28<br />

3 7.8 2.75 6.13 0.25<br />

Fig. V<br />

5-40<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

HID<br />

NOM<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

250 Watt Lamp, ANSI Code S50<br />

120<br />

127/220<br />

277<br />

480<br />

480/120T<br />

71A8201<br />

71A82H1<br />

71A8231<br />

71A8241<br />

71A8241-001D<br />

71A8241-T<br />

CWA 295<br />

CWA<br />

CWA<br />

310<br />

310<br />

Max •<br />

Input<br />

Current<br />

2.5<br />

2.5/1.5<br />

1.1<br />

.7<br />

.7<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

185<br />

185<br />

185<br />

Fuse<br />

Rating<br />

(Amps)<br />

7<br />

7/4<br />

3<br />

2<br />

2<br />

Wiring<br />

Dia<br />

M<br />

M<br />

M<br />

Dimensions<br />

Fig<br />

A<br />

B<br />

Mfd<br />

High Pressure Sodium<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

2 1.8 3.5 35 240 7C350P24 D 11.0 LI501-H4 2<br />

2<br />

2<br />

1.8<br />

1.8<br />

3.5<br />

3.5<br />

35<br />

35<br />

240<br />

240<br />

7C350P24<br />

7C350P24<br />

D<br />

D<br />

11.0<br />

11.0<br />

LI501-H4<br />

LI501-H4<br />

2<br />

2<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

A<br />

D/C<br />

B<br />

B<br />

B<br />

120/277<br />

71A8281 CWA 295 2.5/1.1 185 7/3 M 2 1.8 3.5 35 240 7C350P24 D 11.0 LI501-H4 2 B/B<br />

NOM<br />

120/208/<br />

240/277<br />

71A8291 CWA 295<br />

2.5/1.5/<br />

1.3/1.1<br />

185<br />

7/4/<br />

4/3<br />

M<br />

2 1.8 3.5 35 240 7C350P24 D 11.0 LI501-H4 2<br />

B/A/<br />

B/B<br />

120/208/<br />

240/277 71A8271-001D CWA 295 2.5/1.5/<br />

1.3/1.1<br />

185<br />

7/4/<br />

4/3<br />

M<br />

2 1.8 3.5 35 240 7C350P24 D 11.0 LI501-H4 2<br />

B/A/<br />

B/B<br />

120/208/<br />

240/277/<br />

480<br />

2.6/1.5/<br />

71A8251<br />

71A8251-001D CWA 300 1.3/1.2/<br />

.7<br />

185<br />

10/4/<br />

4/3/<br />

2<br />

M<br />

2 2.0 3.6 35 240 7C350P24 D 12.0 LI501-H4 2<br />

B/B/<br />

B/B/<br />

B<br />

120/<br />

277/347 71A82A1 CWA 295 2.7/<br />

1.2/.9<br />

185<br />

7/<br />

3/2<br />

M<br />

2 2.0 3.6 35 240 7C350P24 D 11.5 LI501-H4 2<br />

C/<br />

C/B<br />

120/<br />

277/347 71A82A1-001D CWA 295 2.7/<br />

1.2/.9<br />

185<br />

7/<br />

3/2<br />

M<br />

2 2.0 3.6 35 240 7C350P24 D 11.5 LI501-H4 2<br />

C/<br />

C/B<br />

120/<br />

208/240 71A82E6 CWI 300 2.8/<br />

1.6/1.4<br />

190<br />

8/<br />

5/5<br />

V<br />

2 1.9 3.8 28 300 7C280P30-R D 11.0 LI501-J4 2<br />

D/<br />

C/C<br />

LL<br />

220/240 71A82J9 CWA 285 1.4/1.3 188 4/4 M 2 1.8 3.4 34 240 7C340P24 D 11.0 LI501-H4 5 A/A<br />

120/208/<br />

240/277<br />

120/240 71A8250<br />

240/480 71A8260<br />

120/277 71A8280<br />

71A8296 CWI 300<br />

Regulated<br />

Lag<br />

Regulated<br />

Lag<br />

Regulated<br />

Lag<br />

2.6/1.5/<br />

1.3/1.2<br />

190<br />

7/5/<br />

3/3<br />

V<br />

2 1.9 3.5 28 300 7C280P30R D 11.0 LI501J4 5<br />

310 2.7/1.4 220 8/4 N 3 2.4 4.0 16 480 MD1606-000 O 18.0 LI501-H4 2 C/C<br />

310 1.4/.7 220 4/2 N 3 2.4 4.0 16 480 MD1606-000 O 18.0 LI501-H4 2 C/C<br />

310 2.7/1.2 220 8/3 N 3 2.4 4.0 16 480 MD1606-000 O 18.0 LI501-H4 2 C/C<br />

E/C/<br />

C/C<br />

HID • CORE & COIL<br />

HPS<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />

Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />

is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />

for additional information.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.pages 5-50 to 5-53 for additional information.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

LL Special High Efficiency/Low Loss Magnetic ballast<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-41


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog<br />

Number †<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

310 Watt Lamp, ANSI Code S67<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Wiring<br />

Rating<br />

Dia<br />

(Amps)<br />

Dimensions<br />

Fig A B Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(lbs)<br />

Ignitor ††<br />

(Page 5-50 to 5-53)<br />

Max<br />

Dist<br />

Part<br />

To<br />

Number<br />

Lamp<br />

(ft)<br />

480 71A8341 CWA 365 0.9 175 3 M 2 2.2 3.8 45 280 7C450P30-R D 13.5 LI501-H4 2 D<br />

120/208/<br />

240/277 71A8391 CWI 365 3.4/1.9/<br />

1.7/1.4<br />

120/208/<br />

240/277 71A8371-001D CWA 365 3.4/1.9/<br />

1.7/1.4<br />

120/240<br />

240/480<br />

71A8350<br />

71A8360<br />

Regulated<br />

Lag<br />

380<br />

120/208/<br />

240/277/ 71A8351 CWA 367<br />

480<br />

3.3/1.7<br />

1.7/.9<br />

3.2/1.7/1<br />

.6/1.4/.8<br />

175<br />

175<br />

210<br />

183<br />

8/5/<br />

5/5<br />

8/5/<br />

5/5<br />

9/4<br />

4/3<br />

8/5/4/<br />

4/2<br />

M 2 2.2 4.1 45 280 7C450P30-R D 13.5 LI501-H4 2<br />

M 2 2.2 4.1 45 280 7C450P30-R D 13.5 LI501-H4 2<br />

N 3 2.8 4.5 17 525 MD1701-000 D 21.0 LI501-H4 2<br />

M 2 2.5 4.1 45 280 7C450P30-R D 14.0 LI501-H4 2<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

D/D/<br />

D/B<br />

D/C/<br />

D/B<br />

C/B<br />

C/B<br />

C/A/B/<br />

B/B<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA and Regulated Lag circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short Range ignitor model<br />

shown for use within fixtures. If a Long Range ignitor is required for remote mounting,<br />

specify on order. See pages 5-50 to 5-53 for additional information.<br />

3 7 /8"<br />

B<br />

MAX.<br />

4 3 /8" 4 3 /4"<br />

A<br />

4 1 /4"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

Fig. 2<br />

(4 1 /4" x 4 3 /4" core)<br />

HID • CORE & COIL<br />

HPS<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

LAMP 1<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP 2<br />

CAP<br />

CAP<br />

LAMP<br />

COM<br />

CAP<br />

Fig. N<br />

LINE V<br />

LAMP 1<br />

LINE V<br />

LINE V<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

COM<br />

CAP<br />

CAP<br />

LAMP 2<br />

Fig. V<br />

LINE V<br />

LAMP<br />

LINE V<br />

WELDED BRACKET DIMENSIONS<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

CAP<br />

CAP<br />

Fig. M<br />

X3 X1<br />

IGNITOR<br />

X2<br />

COM<br />

LAMP<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

2 6.5 1.25 5.75 0.28<br />

3 7.8 2.75 6.13 0.25<br />

5-42<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

HID<br />

High Pressure Sodium<br />

NOM<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

400 Watt Lamp, ANSI Code S51<br />

120 71A8403<br />

127/220 71A84H3 CWA 457<br />

277 71A8433<br />

Max •<br />

Input<br />

Current<br />

3.8<br />

3.7/2.1<br />

1.7<br />

120/208/<br />

71A8453<br />

3.9/2.2/<br />

240/277/<br />

480<br />

71A8453-001D CWA 465 1.9/1.7/<br />

1.0<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

190<br />

195<br />

Fuse<br />

Rating<br />

(Amps)<br />

10<br />

5<br />

5<br />

10/6/<br />

5/5/<br />

3<br />

Wiring<br />

Dia<br />

M<br />

Fig<br />

Dimensions<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

2 2.3 4.0 55 240 7C550P24 D 13.5 LI501-H4 2<br />

71A8443<br />

480<br />

CWA 464 1.0 190 3 M 2 2.6 4.3 55 240 7C550P24 D 15.0 LI501-H4 2<br />

71A8443-001D<br />

480/120T 71A8443-T CWA 464 1.0 190 3 M 2 2.6 4.3 55 240 7C550P24 D 15.0 LI501-H4 2<br />

120/208/<br />

240/277 71A8493 CWA 464 3.8/2.2/<br />

1.9/1.7<br />

120/208/<br />

240/277 71A8473-001D CWA 464 3.8/2.2/<br />

1.9/1.7<br />

120/<br />

277/347 71A84A3 CWA 464 3.8/<br />

1.7/1.3<br />

120/<br />

277/347 71A84A3-001D CWA 464 3.8/<br />

1.7/1.3<br />

190<br />

190<br />

190<br />

190<br />

10/8/<br />

5/5<br />

10/8/<br />

5/5<br />

10/<br />

5/5<br />

10/<br />

5/5<br />

M<br />

M<br />

M<br />

M<br />

M<br />

2 2.3 4.0 55 240 7C550P24 D 13.5 LI501-H4 2<br />

2 2.3 4.0 55 240 7C550P24 D 13.5 LI501-H4 2<br />

2 2.7 4.4 55 240 7C550P24 D 16.0 LI501-H4 2<br />

2 2.3 4.0 55 240 7C550P24 D 13.5 LI501-H4 2<br />

2 2.3 4.0 55 240 7C550P24 D 13.5 LI501-H4 2<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

D<br />

D/C<br />

D<br />

D<br />

D<br />

D/D/<br />

D/D<br />

D/D/<br />

D/D<br />

C/C/<br />

D/D/<br />

C<br />

D/<br />

D/D<br />

D/<br />

D/D<br />

120/<br />

208/240 71A84E6 CWI 465 4.2/<br />

2.4/2.1<br />

190<br />

10/<br />

7/5<br />

V<br />

2 2.7 4.4 48 300 7C480P30 D 15.5 LI501-J4 2<br />

E/<br />

E/E<br />

120/240 71A8456 CWI 465 4.2/2.1 190 10/5 M 2 2.7 4.4 48 300 7C480P30 D 15.5 LI501-J4 2<br />

480/120T<br />

120/240<br />

120/277<br />

240/480<br />

71A8440-T<br />

71A8450<br />

71A8480<br />

71A8460<br />

Regulated<br />

Lag<br />

490<br />

1.1<br />

4.2/2.1<br />

4.2/1.8<br />

2.1/1.1<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA, CWI and Regulated Lag circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />

Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />

is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />

for additional information.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

215<br />

5<br />

10/5<br />

10/5<br />

5/5<br />

N<br />

3 3.6 5.3 24 480 MD2409-000 O 26.0 LI501-H4 2<br />

E/E<br />

C<br />

D/C<br />

D/C<br />

D/B<br />

HID • CORE & COIL<br />

HPS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-43


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

High Pressure Sodium<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

Input<br />

Volts<br />

430 Watt Lamp, ANSI Code S145 (SON AGRO-Philips)<br />

120/<br />

208/240<br />

277/<br />

347/480<br />

600 Watt Lamp, ANSI Code S106<br />

120/<br />

208/240<br />

277/<br />

347/480<br />

120/<br />

208/240<br />

277/<br />

347/480<br />

71A85E5 CWA 670<br />

71A85F5<br />

5.5/<br />

3.3/2.9<br />

220<br />

2.5/<br />

CWA 665 230<br />

2.0/1.4<br />

750 Watt Lamp, ANSI Code S111<br />

120/<br />

208/240<br />

277/<br />

347/480<br />

Catalog✝<br />

Number<br />

71A85E6<br />

71A85F6<br />

71A85E8<br />

71A85F8<br />

Circuit<br />

Type<br />

CWI<br />

CWI<br />

CWI<br />

CWI<br />

Watts<br />

Input<br />

490<br />

490<br />

685<br />

685<br />

71A86E5 CWA 840<br />

71A86F5 CWA 840<br />

Max•<br />

Input<br />

Current<br />

5.2/<br />

3.0/2.6<br />

2.3/<br />

1.8/1.3<br />

6.2/<br />

3.5/3.1<br />

2.6/<br />

2.1/1.5<br />

6.8/<br />

4.0/3.5<br />

3.1/<br />

2.5/1.8<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

200<br />

200<br />

240<br />

238<br />

220<br />

225<br />

Fuse<br />

Rating<br />

(Amps)<br />

15/<br />

10/7<br />

7/<br />

5/5<br />

15/<br />

9/8<br />

7/<br />

5/4<br />

20/<br />

9/8<br />

7/<br />

6/5<br />

20/<br />

10/10<br />

10/<br />

10/5<br />

Wiring<br />

Dia<br />

Y<br />

V<br />

M<br />

M<br />

V<br />

V<br />

M<br />

M<br />

Dimensions<br />

Fig<br />

2<br />

2<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

15.0<br />

8a 3.2 5.1 64 280 7C640S28-R D 22.5 LI561-H5 2<br />

8a 3.2 5.1 64 280 7C640S28-R D 23.0 LI561-H5 5<br />

8a<br />

8a<br />

A<br />

2.6<br />

2.6<br />

3.4<br />

3.4<br />

B<br />

4.1<br />

4.1<br />

5.3<br />

5.3<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

48 300 7C480P30<br />

48 300 7C480P30 D 15.0<br />

48 330 7C480S33-R<br />

8a 3.2 5.1 75 280 7C750S28-R D 22.5 LI561-H5 5<br />

8a 3.2 5.1 75 280 7C750S28-R D 23.0<br />

D<br />

D<br />

Total<br />

Weight<br />

(Ibs)<br />

26.0<br />

48 330 7C480S33-R D 26.0<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

LI501-H4<br />

LI501-H4<br />

LI561-H5<br />

LI561-H5<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

15<br />

15<br />

2<br />

2<br />

LI561-H5 5<br />

U.L. Bench Top<br />

Rise Code 1029<br />

(Pg 5-3)<br />

ADVANCE<br />

Class H<br />

Class N<br />

(180°C)<br />

(200°C)<br />

C/<br />

E/D<br />

F/<br />

C/B<br />

A/<br />

A/B<br />

A/<br />

A/A<br />

D/<br />

D/C<br />

D/<br />

D/C<br />

D/<br />

E/E<br />

E/<br />

D/D<br />

—<br />

—<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

HID • CORE & COIL<br />

HPS<br />

✝ Ordering information:<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA and CWI circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short Range ignitor<br />

model shown for use within fixtures. If a Long Range ignitor is required for remote<br />

mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />

N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />

Refer to page 5-3 for additional information.<br />

B<br />

MAX.<br />

3 7 /8"<br />

4 1 /4"<br />

A<br />

4 3 /8"<br />

5 3 /8" 6 "<br />

8 Holes cleared for<br />

#10 thru-bolts<br />

Fig. 88a<br />

(4 1 /4" x 6" core)<br />

B<br />

MAX.<br />

A<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

LINE V<br />

LAMP<br />

H4<br />

H4<br />

H4<br />

LAMP 1<br />

4 1 /4"<br />

LINE V<br />

208 V<br />

208 V<br />

208 V<br />

LINE V<br />

LINE V<br />

CAP<br />

CAP<br />

CAP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

120 V<br />

H2<br />

H3<br />

H1<br />

208V H2<br />

H3<br />

H1<br />

240 V H2<br />

H3<br />

H1<br />

CAP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

CAP<br />

LAMP 2<br />

LAMP<br />

3 7 /8"<br />

4 3 /8" 4 3 /4"<br />

Fig. 2<br />

(4 1 /4" x 4 3 /4" core)<br />

COM<br />

Fig. M<br />

COM<br />

Fig. Y<br />

LINE V<br />

LAMP 1<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

X3 X1<br />

IGNITOR<br />

X2<br />

CAP<br />

LAMP 2<br />

LAMP<br />

WELDED BallastBRACKET L DIMENSIONS W M<br />

Dimensions Fig<br />

S<br />

2 6.5 1.25 5.75 0.28<br />

8a 7.8 4.50 6.75 0.31<br />

Fig. V<br />

5-44<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

HID<br />

High Pressure Sodium<br />

NOM<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

N<br />

Input<br />

Volts<br />

1000 Watt Lamp, ANSI Code S52<br />

120<br />

220<br />

277<br />

480<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277<br />

120/208/<br />

240/277/<br />

480<br />

Catalog✝<br />

Number<br />

71A8703<br />

71A87J3<br />

71A8733<br />

71A8743<br />

71A8743-001<br />

71A8793 CWA 1100<br />

9.5/5.5/<br />

4.8/4.2<br />

71A8773-001 CWA 1100<br />

9.5/5.5/<br />

4.8/4.2<br />

71A8753<br />

71A8753-001<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

CWA 1100<br />

120/<br />

277/347 71A87A3 CWA 1100 9.5/<br />

4.2/3.3<br />

120/<br />

277/347 71A87A3-001 CWA 1100 9.5/<br />

4.2/3.3<br />

435<br />

435<br />

435<br />

25/15/<br />

10/10<br />

25/15/<br />

10/10<br />

25/15/<br />

12/10/<br />

6<br />

25/<br />

15/10<br />

Cap Catalog<br />

Number<br />

CWA 1100 2.3 435 6 M 8a 3.9 5.8 26 525 MD2602-030 O 28.0 LI571-H5 ★ 15 C<br />

CWA 1100<br />

Max•<br />

Input<br />

Current<br />

9.2<br />

5.0<br />

4.0<br />

9.3/5.3/<br />

4.7/4.1/<br />

2.3<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

435<br />

437<br />

435<br />

Fuse<br />

Rating<br />

(Amps)<br />

25<br />

15<br />

10<br />

25/<br />

15/10<br />

Wiring<br />

Dia<br />

M<br />

M<br />

M<br />

M<br />

Dry<br />

or<br />

Oil<br />

M 8a 3.8 5.8 26 525 MD2602-030 O 28.0 LI571-H5 ★ 15<br />

M<br />

Dimensions<br />

Fig<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Total<br />

Weight<br />

(Ibs)<br />

8a 3.8 5.8 26 525 MD2602-030 O 28.0<br />

8a 3.8 5.8 26 525 MD2602-030 O 28.0<br />

8a 4.0 6.0 26 525 MD2602-030 O 29.0<br />

8a 3.9 5.9 26 525 MD2602-030 O 28.0<br />

8a 3.9 5.9 26 525 MD2602-030 O 28.0<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

LI571-H5 ★ 15<br />

LI571-H5 ★ 15<br />

LI571-H5 ★ 15<br />

LI571-H5 ★ 15<br />

LI571-H5 ★ 15<br />

U.L. Bench Top<br />

Rise Code 1029<br />

(Pg 5-3)<br />

ADVANCE<br />

Class H<br />

Class N<br />

(180°C)<br />

(200°C)<br />

B<br />

C<br />

C<br />

C/B/<br />

C/C<br />

C/B/<br />

C/C<br />

C/C/<br />

C/C/<br />

C<br />

C/<br />

C/C<br />

C/<br />

C/C<br />

A<br />

A<br />

A<br />

A<br />

A/A/<br />

A/A<br />

A/A/<br />

A/A<br />

A/A/<br />

A/A/<br />

A<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For CWA circuits, figure is operating current.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />

Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />

is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />

for additional information.<br />

★ Equipped with an auto-reset thermal protector to prevent ignitor from overheating<br />

in the event of lamp failure.<br />

Canadian replacement/retrofit ballast kit indicated by bold type.<br />

Refer to page 5-10.<br />

N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />

Refer to page 5-3 for additional information.<br />

NOM Certified ballast available for Mexican and Central American markets.<br />

HID • CORE & COIL<br />

HPS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-45


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Low Pressure Sodium<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

U.L.<br />

Bench<br />

Top Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

18 Watt Lamp, ANSI Code L69<br />

120/277 71A0280<br />

HX-NPF<br />

HX-PFC<br />

30<br />

.9/.4<br />

1.0/.5<br />

315<br />

3/2<br />

3/2<br />

Q<br />

1 1.0 2.4<br />

—<br />

5<br />

—<br />

250<br />

—––––––<br />

7C050L33<br />

D<br />

4.0<br />

4.5<br />

A/A<br />

35 Watt Lamp, ANSI Code L70<br />

or 55 Watt Lamp, ANSI Code L71<br />

New<br />

120/208/<br />

240/277<br />

71A0490<br />

71A0490-001D<br />

HX-HPF/<br />

HX-PFC<br />

60 or 80<br />

2.35/1.39/<br />

1.18/0.98<br />

480<br />

6/4/<br />

3/3<br />

Q<br />

1<br />

2.3 3.5 14 240 7C140M33-R D 8.0<br />

A/A/<br />

A/A<br />

New<br />

347/480 71A04F0 HX-HPF 60 or 80 0.79/0.58 480 2/2 Q2 1 2.3 3.5 14 240 7C140M33-R D 8.0 A/A<br />

= Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For HX circuits, figure is highest of starting, operating or open circuit current.<br />

B<br />

MAX.<br />

A<br />

2 13 /16"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

2 7 /16"<br />

3 1 /2" 3 15 /16"<br />

Fig. 1<br />

(3" x 4" core)<br />

B<br />

MAX.<br />

A<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

4 1 /4"<br />

HID • CORE & COIL<br />

LPS<br />

LINE V<br />

CAP<br />

LAMP<br />

LAMP<br />

3 7 /8"<br />

4 3 /8" 4 3 /4"<br />

Fig. 2<br />

(4 1 /4" x 4 3 /4" core)<br />

COM<br />

COM<br />

Fig. B<br />

LINE V<br />

LAMP<br />

CAP<br />

LAMP<br />

LINE V<br />

LINE V<br />

CAP<br />

LAMP<br />

COM<br />

CAP<br />

LINE V<br />

LAMP<br />

WELDED BRACKET DIMENSIONS<br />

Fig. C<br />

COM<br />

Fig. Q<br />

COM<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

2 6.5 1.25 5.75 0.28<br />

3 7.8 2.75 6.13 0.25<br />

5-46<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Low Pressure Sodium<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

U.L.<br />

Bench<br />

Top Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

90 Watt Lamp, ANSI Code L72<br />

New<br />

120/208/<br />

240/277<br />

71A0590<br />

71A0590-001D<br />

HX-HPF 125<br />

4.1/2.3/<br />

2.0/1.75<br />

515<br />

11/6/<br />

5/5<br />

Q4<br />

2 1.8 3.3 17.5 330 7C175M33-R<br />

D<br />

10.0<br />

A/A/<br />

A/A<br />

New<br />

347/480 71A05F0 HX-HPF 125 1.35/0.95 520 4/3 Q2 2 1.8 3.4 16.0 330 7C160M33 D 10.2 A/A<br />

New<br />

New<br />

135 Watt Lamp, ANSI Code L73<br />

180 Watt Lamp, ANSI Code L74<br />

120/208/<br />

240/277<br />

71A0790<br />

71A0790-001D<br />

HX-HPF<br />

347/480 71A07F0 HX-HPF<br />

180 or<br />

208<br />

182 or<br />

213<br />

5.28/2.82/<br />

2.65/2.25<br />

695<br />

15/7/<br />

7/6<br />

Q<br />

3 2.4 4.0 16 330 7C160M33<br />

1.82/1.33 690 5/4 Q2 3 2.4 4.0 16 330 7C160M33 D 15.0 A/A<br />

D<br />

15.3<br />

A/A/<br />

A/A<br />

✝ Ordering information:<br />

Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />

Refer to pages 5-5 to 5-9.<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

-610 core & coil with welded bracket (no capacitor)<br />

• For HX circuits, figure is highest of starting, operating or open circuit current.<br />

HID • CORE & COIL<br />

LPS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-47


HID - NON-PCB CAPACITORS<br />

HID • CAPACITORS<br />

CAPACITOR SPECIFICATIONS<br />

Height<br />

New<br />

Max<br />

Case<br />

Temp<br />

105°C<br />

Diameter<br />

Dry-Film<br />

Capacitors<br />

Thermal<br />

Plastic Case<br />

Dry-film capacitors<br />

contain no oil; are<br />

furnished with 8”<br />

leads and include<br />

integral resistor<br />

where required.<br />

CC-175<br />

Mounting Clip<br />

For 1.25 thru 1.75 in. diameter Round<br />

Case (Furnished as standard with -001<br />

and -001 D suffix ballasts).<br />

Max Case<br />

Temp 90°C<br />

3/16” Dia.<br />

Recommended Capacitors for Bi-level Ballast Operation<br />

<strong>Advance</strong><br />

Ballast Family<br />

Nominal<br />

Lamp Watts<br />

ANSI<br />

Code<br />

2 1/8”<br />

Lamp Watts<br />

at Low Light<br />

Metal Halide 60 Hz CWA/SuperCWA <strong>Ballasts</strong><br />

71A54_3 150<br />

M102/14<br />

2<br />

CC-200<br />

Mounting Clip<br />

For 2.00 in. diameter Round<br />

Case. Mount in the middle of can.<br />

Full Light<br />

Capacitance Mfd.<br />

Oil-Filled Capacitor<br />

Furnished with appropriate leads<br />

and/or resistors where required.<br />

Case must be grounded.<br />

Note: Capacitor boots available,<br />

order catalog number CB-100.<br />

Low Light<br />

Capacitance Mfd.<br />

90 22.0 15.0<br />

71A55_0 175 M57 122 10.0 8.0<br />

71A55_3<br />

71A56_2 or<br />

71A56_3<br />

71A57_0 or<br />

71A57_1<br />

71A57_2<br />

71A58_2<br />

71A59_3<br />

175<br />

Pulse-Start<br />

200<br />

Pulse-Start<br />

M137 or<br />

M152<br />

102 11.0 7.7<br />

M136 102 15.0 9.3<br />

250 M58 127 15.0 9.0<br />

250<br />

Pulse-Start<br />

320<br />

Pulse-Start<br />

350<br />

Pulse-Start<br />

M138 or<br />

M153<br />

M132 or<br />

M154<br />

133 17.0 10.8<br />

149 21.0 13.1<br />

M131 163 22.5 14.4<br />

71A60_1 400 M59 192 24.0 15.0<br />

71A60_2<br />

71A63_2<br />

71A64_2<br />

71A65_0, 71A65_1,<br />

71A65_2, or 71A65_3<br />

400<br />

Pulse-Start<br />

450<br />

Pulse-Start<br />

750<br />

Pulse-Start<br />

1000 Probe or<br />

Pulse-Start<br />

M135 or<br />

M155<br />

210 26.0 18.5<br />

M144 212 26.5 16.7<br />

M149 380 28.0 18.0<br />

M47 or<br />

M141<br />

Max<br />

Case<br />

Temp<br />

105°C<br />

571 24.0 15.0<br />

71A80_8 100 S54 52 34.0 26.0<br />

71A81_8 150 S55 66 55.0 40.0<br />

Dry-Film Capacitors<br />

Dimensions (in)<br />

Letter Diameter Height<br />

L 1.25 2.9<br />

M 1.50 2.9 or 3.75<br />

P 1.75 3.75 or 5.15<br />

S 2.00 5.15<br />

Primary<br />

Capacitor<br />

22.0 mfd, 240V<br />

(7C220M24-R)<br />

10 mfd, 400V<br />

(7C100M40-R)<br />

11 mfd, 400V<br />

(7C110M40)<br />

15 mfd, 330V<br />

(7C150M33)<br />

15 mfd, 400V<br />

(7C150P40-R)<br />

17 mfd, 330V<br />

(7C170M33)<br />

21 mfd, 345V<br />

(7C210P34-R)<br />

22.5 mfd, 345V<br />

(7C225P34)<br />

24 mfd, 400V<br />

(7C240P40-R)<br />

18.5 mfd, 330V<br />

(7C185P33-R)<br />

26.5 mfd, 400V<br />

(7C265P40-R)<br />

18 mfd, 400V<br />

(7C180P40-R)<br />

24 mfd, 480V<br />

(MD2409-100)<br />

26.0 mfd, 330V<br />

(7C260P33-R)<br />

40 mfd, 300V<br />

(7C400P30-R)<br />

28 mfd, 300V<br />

(7C280P30-R)<br />

40 mfd, 300V<br />

(7C400P30-R)<br />

35 mfd, 300V (7C350P30-R)<br />

in parallel with 20 mfd, 300V<br />

(7C200P33-R)<br />

26 mfd, 525V<br />

(MD2602-030)<br />

Secondary<br />

Capacitor<br />

48.0 mfd, 300V<br />

(7C480P30)<br />

40 mfd, 300V<br />

(7C400P30-R)<br />

26 mfd, 330V<br />

(7C260:33-R)<br />

24 mfd, 300V<br />

(7C240P30)<br />

22.5 mfd, 300V<br />

(7C225P30-R)<br />

30 mfd, 345V<br />

(7C300S34)<br />

35 mfd, 300V<br />

(7C350P30-R)<br />

40 mfd, 300V<br />

(7C400 P30-R)<br />

40 mfd, 300V<br />

(7C400P30-R)<br />

7.5 mfd, 330V<br />

(7C075L33)<br />

45.0 mfd, 120V<br />

(7C450P12)<br />

10 mfd, 400V<br />

(7C100M40-R)<br />

40 mfd, 300V<br />

(7C400P30-R)<br />

8.0 mfd, 330V<br />

(7C080L33-R)<br />

15 mfd, 330V<br />

(7C150M33)<br />

7 mfd, 330V<br />

(7C070L33-R)<br />

15 mfd, 330V<br />

(7C150M33)<br />

Capacitor<br />

Connection<br />

71A53_3 100 M90/140 55 10.0 7.8 10.0 mfd 330V 35.0 mfd 300V Series<br />

71A64_8 875 - 440 21.0 13.1 21 mfd 480V 35 mfd 170V Series<br />

71A64_8 875 - 440 21.0 13.1 13 mfd 480V 8 mfd 480V Parallel<br />

High Pressure Sodium 60 Hz CWA <strong>Ballasts</strong><br />

New<br />

71A82_1 250 S50 144 35.0 28.0<br />

71A84_3 400 S51 189 55.0 40.0<br />

71A86_5 750 S111 356 75.0 55.0<br />

71A87_3 1000 S52 406 26.0 17.7<br />

Oil-Filled Capacitors<br />

Dimensions (in)<br />

Oval A B Height<br />

1.25 1.30 2.15<br />

1.25 1.55 2.70 As Shown<br />

1.75 1.90 2.90 in Tables<br />

2.00 1.95 3.65<br />

20 mfd, 330V<br />

(7C200P33-R)<br />

55 mfd, 240V<br />

(7C550P24)<br />

71A89_1 200 S66 130 24.0 18.0 24 mfd 280V 72 mfd 120V Series<br />

Series<br />

Series<br />

Series<br />

Series<br />

Series<br />

Series<br />

Series<br />

Series<br />

Series<br />

Parallel<br />

Series<br />

Parallel<br />

Series<br />

Parallel<br />

Parallel<br />

Parallel<br />

Parallel<br />

Parallel<br />

Series<br />

71A89_1 200 S66 130 24.0 18.0 18 mfd 280V 6 mfd 280V Parallel<br />

5-48<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HID - NON-PCB CAPACITORS<br />

Capacitor Specifications<br />

Mfd.<br />

5.0<br />

6.0<br />

7.0<br />

7.5<br />

8.0<br />

8.4<br />

10.0<br />

10.0<br />

11.0<br />

12.0<br />

12.0<br />

13.0<br />

13.0<br />

14.0<br />

14.0<br />

15.0<br />

15.0<br />

16.0<br />

16.0<br />

16.0<br />

16.0<br />

17.0<br />

17.0<br />

17.0<br />

17.5<br />

18.0<br />

18.5<br />

20.0<br />

20.0<br />

20.0<br />

21.0<br />

21.0<br />

22.0<br />

22.5<br />

22.5<br />

22.5<br />

24.0<br />

24.0<br />

24.0<br />

24.0<br />

24.0<br />

25.5<br />

26.0<br />

26.0<br />

26.0<br />

26.0<br />

26.5<br />

28.0<br />

28.0<br />

28.0<br />

28.0<br />

30.0<br />

32.0<br />

34.0<br />

34.0<br />

35.0<br />

35.0<br />

36.0<br />

40.0<br />

40.0<br />

45.0<br />

45.0<br />

48.0<br />

48.0<br />

48.0<br />

52.0<br />

52.0<br />

52.0<br />

55.0<br />

55.0<br />

55.0<br />

58.0<br />

60.0<br />

64.0<br />

66.0<br />

75.0<br />

Voltage<br />

330<br />

330<br />

330<br />

330<br />

330<br />

330<br />

330<br />

400<br />

400<br />

330<br />

450<br />

330<br />

525<br />

120<br />

330<br />

330<br />

400<br />

300<br />

400<br />

525<br />

525<br />

400<br />

550<br />

550<br />

300<br />

400<br />

330<br />

120<br />

330<br />

450<br />

345<br />

525<br />

240<br />

300<br />

345<br />

345<br />

300<br />

400<br />

400<br />

480<br />

480<br />

400<br />

330<br />

330<br />

540<br />

540<br />

400<br />

120<br />

300<br />

400<br />

580<br />

345<br />

525<br />

240<br />

550<br />

240<br />

300<br />

120<br />

120<br />

300<br />

120<br />

300<br />

300<br />

300<br />

330<br />

120<br />

240<br />

280<br />

120<br />

240<br />

240<br />

240<br />

240<br />

280<br />

280<br />

280<br />

7C Dry Capacitor<br />

Part Number<br />

7C050L33<br />

7C060L33<br />

7C070L33R<br />

7C075L33<br />

7C080L33R<br />

7C084L33R<br />

7C100M33R<br />

7C100M40R<br />

7C110P40<br />

7C120M33R<br />

MD1204-100<br />

7C130M33<br />

MD1300-100<br />

7C140L12<br />

7C140M33R<br />

7C150M33<br />

7C150P40R<br />

7C160M30<br />

7C160P40<br />

MD1606-000<br />

MD1606-100<br />

7C170P40<br />

MD1701-000<br />

MD1701-100<br />

7C175M30R<br />

7C180P40R<br />

7C185P33R<br />

7C200M12<br />

7C200P33R<br />

MD2006-100<br />

7C210P34R<br />

MD2100-030<br />

7C220M24R<br />

7C225P30R<br />

7C225P34<br />

7C225S34<br />

7C240P30<br />

7C240P40R<br />

7C240S40R<br />

MD2409-000<br />

MD2409-100<br />

7C255P40R<br />

7C260P33R<br />

7C260S33R<br />

MD2602-030<br />

MD2602-100<br />

7C265P40R<br />

7C280M12<br />

7C280P30R<br />

7C280S40<br />

MD1408-230<br />

7C300S34<br />

MD3202-100<br />

7C340P24<br />

MD1701-200<br />

7C350P24<br />

7C350P30R<br />

7C360M12<br />

7C400P30R<br />

7C450P12<br />

7C450P30R<br />

7C480P30<br />

7C480P30R<br />

7C480S33R<br />

7C520P12<br />

7C520P24<br />

7C520S28R<br />

7C550P12<br />

7C550P24<br />

7C550P24R<br />

7C580P24<br />

7C600P24<br />

7C640S28R<br />

7C660S28<br />

7C750S28R<br />

7T Dry Capacitor<br />

Part Number<br />

7T160P40R<br />

7T180P40R<br />

7T200P33R<br />

7T225P30R<br />

7T240P30R<br />

7T240S40R<br />

7T280P12R<br />

7T280P30R<br />

7T300S34R<br />

7T340P24R<br />

7T350P24R<br />

7T360P12R<br />

7T400P12R<br />

7T400S30R<br />

7T450S30R<br />

7T550P12R<br />

Dia/Oval<br />

7C/7T<br />

1.25<br />

1.25<br />

1.25<br />

1.25<br />

1.25<br />

1.50<br />

1.50<br />

1.50<br />

1.75<br />

1.75<br />

1.75<br />

1.25<br />

1.75<br />

1.50<br />

1.50<br />

1.75<br />

1.50<br />

1.75<br />

1.75<br />

1.75<br />

1.75<br />

1.75<br />

1.75<br />

1.75<br />

1.50<br />

1.75<br />

1.75<br />

1.75<br />

1.50<br />

1.75<br />

1.75<br />

1.75<br />

1.50<br />

1.75<br />

1.75<br />

2.00<br />

1.75<br />

1.75<br />

2.00<br />

1.75<br />

1.75<br />

1.75<br />

1.75<br />

2.00<br />

1.75<br />

1.75<br />

1.75<br />

1.5/1.75<br />

1.75<br />

2.00<br />

1.50<br />

2.00<br />

2.00<br />

1.75<br />

1.75<br />

1.75<br />

1.75<br />

1.50<br />

2.00<br />

1.75/2.00<br />

1.75<br />

1.75/2.00<br />

1.75<br />

1.75<br />

2.00<br />

1.75<br />

1.75<br />

1.75<br />

1.75<br />

1.75<br />

1.75<br />

2.00<br />

1.75<br />

2.00<br />

2.00<br />

2.00<br />

Height<br />

7C/7T<br />

2.90<br />

2.90<br />

2.90<br />

2.90<br />

2.90<br />

2.90<br />

3.75<br />

3.75<br />

3.75<br />

3.75<br />

2.90<br />

3.75<br />

3.90<br />

2.90<br />

3.75<br />

3.75<br />

3.75<br />

3.75<br />

3.75/4.70<br />

3.90<br />

3.90<br />

3.75<br />

3.90<br />

3.90<br />

3.75<br />

3.75/4.70<br />

3.90<br />

3.90<br />

3.75/4.70<br />

3.90<br />

5.12<br />

4.80<br />

2.90<br />

3.75/4.70<br />

5.12<br />

3.75<br />

3.75/4.70<br />

5.12<br />

3.75/4.70<br />

3.90<br />

3.90<br />

3.75<br />

5.12<br />

3.75<br />

5.30<br />

5.30<br />

5.12<br />

2.90/4.70<br />

3.75/4.70<br />

5.12<br />

3.90<br />

5.12/4.70<br />

3.90<br />

3.75/4.70<br />

3.90<br />

3.75/4.70<br />

5.12<br />

3.75/4.70<br />

4.70<br />

5.12/4.70<br />

3.75<br />

5.12/4.70<br />

5.12<br />

5.12<br />

5.12<br />

3.75<br />

5.12<br />

3.90<br />

5.12/4.70<br />

3.75<br />

5.12<br />

5.12<br />

5.12<br />

5.12<br />

5.12<br />

5.12<br />

Ballast family where used<br />

71A02x0, 5037, 5081, 5137, 78x1 (60 Hz)<br />

71A5181, 78R1<br />

71A1580, 50x7 (50 Hz. only), 79x1 (60 Hz)<br />

Bi-Level<br />

71A20x0, 52x0, 52x2 (60 Hz. only), 5237, 5281<br />

71A79x1 (50 Hz)<br />

71A25x1 (60 Hz), 50Y1, 52Y1, 52Y2, 5337, 5340-T, 5383, 53Y3, 80x1 (60 Hz)<br />

71A55x0 (60 Hz)<br />

71A55x3<br />

71A25x1 (50 Hz), 29D1, 50x1 (50 Hz), 53x0 (60Hz, except 5340-T), 5637, 80x1 (50 Hz)<br />

71A55x0 (50 Hz)<br />

Bi-Level<br />

71A57E6<br />

71A7707<br />

71A04x0, 29R0, 52x1 (50 Hz), 52x2 (50 Hz), 5437, 5737, 81x2 (60 Hz)<br />

71A56x2, 56x3<br />

71A57x0 (60 Hz), 57x1<br />

71A05F0, 54x0, 54x2, 80x0<br />

71A81x0, 07x0<br />

71A57x4, 82x0<br />

71A43x0<br />

71A55x4, 57x2, 5634, 56x3 (50 Hz)<br />

71A83x0<br />

71A69x0 (Use one 17 mfd-550V and one 26 mfd-540V in parallel)<br />

71A0590, 30x2, 53N0, 5837, 81x2 (50 Hz)<br />

71A57x0 (50 Hz), 89x4<br />

Bi-Level<br />

71A0201, 7705, 7807<br />

71A57x2 (50 Hz), 53MO, 5880, 5937, 6037, 6137, 79xO, 81R6, 8146, 8176, 8196<br />

71A60x6<br />

71A58x2 (60 Hz)<br />

71A59x4, 60x4 (60 Hz), 6334, 64x8<br />

71A54A3<br />

71A35x2 (60 Hz), 5486, 6337<br />

71A59x3<br />

Alternative to 7C225P34<br />

71A79x6, 89x1<br />

71A58x2 (50 Hz), 60x1 (60 Hz), 63x2<br />

Alternative to 7C240P40R<br />

71A84x0, 65x3 (60 Hz), 65x1<br />

71A50x0, 60N1, 65x2 (60 Hz), 65x0<br />

71A59x3 (50 Hz)<br />

71A60x2 (60 Hz), 61E6<br />

Alternative to 7C260P33R<br />

71A69x0 (Uses one 17 mfd-540V and one 26 mfd-540V capacitor in parallel), 87x3 (60 Hz)<br />

71A60M2, 65x2 (50 Hz), 65x3 (50 Hz only)<br />

71A63x3 (60 Hz)<br />

71A5005, 5105, 7805, 7907<br />

71A35R2, 54x2 (50 Hz), 79x8, 82x6, 89x0<br />

71A64x0, 64x2 (60 Hz)<br />

71A87x3 (50 Hz only, uses two 14mfd-580 volt capacitors in parallel)<br />

71A60N2<br />

71A67x2 (60 Hz)<br />

71A80x8<br />

71A68x0 (Uses two 17mfd-550 volt capacitors in parallel)<br />

71A54M2, 80x6, 82x1 (60 Hz)<br />

71A40x1 (60 Hz)<br />

71A5205, 8007, 50Y5<br />

71A40R1, 65E6 (two in series), 82x1 (50 Hz only), 65Y6 (two in series)<br />

71A8005<br />

71A65M6, 83x1<br />

71A84x6, 85x6<br />

71A84x6, 85x6<br />

71A85x8<br />

71A8156, 81E6<br />

Bi-Level<br />

71A8107<br />

71A81x8, 84x3 (60 Hz)<br />

Alternative to 7C550P24<br />

71A8593<br />

71A84x3 (50 Hz), 85x5<br />

71A86x5<br />

HID • CAPACITORS<br />

1. All capacitors contain no PCB’s. 2. Capacitors include a discharge resistor where required by UL. 3. MD_ Denotes 90° Oil Filled, 7C_ Denotes 105° Dry Film.<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-49


HID - CORE & COIL BALLASTS<br />

IGNITORS<br />

<strong>Ballasts</strong> that include an ignitor to start the HID lamp are<br />

limited in the distance which they may be mounted remotely<br />

from the lamp because the ignitor pulse attenuates as the wire<br />

length between the ballast and lamp increases. All <strong>Advance</strong><br />

Transformer Co. open core & coil ballasts listed in this <strong>Atlas</strong><br />

include a standard ignitor that provides the proper electrical<br />

pulse to start lamps when the ballast is mounted within the<br />

lighting fixture. For most of these ballast/ignitor combinations,<br />

the maximum ballast-to-lamp distance is listed as 2 feet.<br />

For ballast-to-lamp distances greater than the capability of the<br />

standard ignitor, a long range ignitor is required.<br />

Use the tables on the following pages to find the proper<br />

long range ignitor for various metal halide and high pressure<br />

sodium ballasts. Not all ballasts listed in the <strong>Atlas</strong> have long<br />

range ignitor options. It may be necessary to use a ballast<br />

employing a different circuit to achieve the needed ballast-tolamp<br />

distance.<br />

Whichever ignitor is used, it must be installed with and<br />

adjacent to the core & coil, as the two components work<br />

together to deliver the proper pulse to the lamp. Do not install<br />

ignitors next to a remote lamp because the electrical pulse will<br />

be further attenuated as it first has to travel from the ignitor to<br />

the core & coil and then back to the lamp, thus doubling the<br />

actual ballast-to-lamp distance.<br />

When ordering ballasts with long range ignitors, indicate<br />

such on the purchase order, e.g.:<br />

71A8493-500D except with LI501-J4 L.R. Ignitor<br />

BALLAST-TO-LAMP REMOTE MOUNTING DISTANCES<br />

MERCURY VAPOR AND METAL HALIDE BALLASTS<br />

The distances at which most Mercury Vapor and Metal<br />

Halide ballasts can be located from their respective lamps are<br />

limited by the ballast-to-lamp wire size. The exceptions being<br />

the ballasts for the new, Metal Halide lamps which require an<br />

ignitor for starting. The mounting distances for these are limited<br />

by the ignitor as shown on the following page.<br />

Use this chart to determine the minimum wire size<br />

required for the Mercury and Metal Halide (not requiring an<br />

ignitor) lamps shown:<br />

LAMP<br />

MAXIMUM ONE-WAY<br />

LENGTH OF WIRE BETWEEN<br />

LAMP AND BALLAST (FEET)<br />

(Voltage Drop Limited to<br />

1% of Lamp Voltage)<br />

Wattage Mercury<br />

Metal<br />

Halide<br />

#10 #12 #14 #16 #18<br />

100 H38 — 750 470 295 185 115<br />

175 H39 M57 425 265 165 105 65<br />

250 H37 M58 300 190 120 75 45<br />

1-400 or<br />

2-400<br />

H33 M59 200 125 75 50 30<br />

700 H35 — 465 290 180 115 70<br />

1000 H36 M47 325 205 125 80 50<br />

1500 — M48 225 140 85 55 35<br />

HID • IGNITORS<br />

ADVANCE INSTANT RESTRIKE IGNITOR<br />

The <strong>Advance</strong> Instant Restrike Ignitor enhances the performance<br />

of high pressure sodium ballasts for applications in which<br />

quick restart is essential. If the lamp extinguished due to a system<br />

voltage dip, the ignitor is enabled and pulses to restrike the lamp.<br />

Should the lamp extinguish due to high lamp voltage (characteristic<br />

at end of lamp life), the ignitor prevents lamp cycling by remaining<br />

disabled and not restriking the lamp. When the lamp is inoperative,<br />

the Instant Restrike Ignitor automatically shuts off to avoid continuos,<br />

high energy pulsing. The Instant Restrike Ignitor is for use with:<br />

• <strong>Advance</strong> high reactance or reactor ballasts only. Mains voltage<br />

must be 120v, or ballast must have a 120v tap available, for<br />

powering the LI555-IR ignitor.<br />

• Mogul-based high pressure sodium lamps rated 150 watts<br />

(55-volt lamps only).<br />

• 5kv pulse-rated mogul-based lamp sockets.<br />

• Maximum recommended ballast to lamp distance is 2 ft.<br />

For complete details of the <strong>Advance</strong> Instant Restrike Ignitor,<br />

refer to <strong>Advance</strong> Form No. HI-4090-R01.<br />

WIRING DIAGRAMS<br />

LI555-IR<br />

DIMENSIONS<br />

5"<br />

LI555-IR<br />

Instant Restrike Ignitor<br />

Catalog Number<br />

LI555-IR<br />

CC-200<br />

2"<br />

Description<br />

Ignitor packed 24 per carton (may order any quantity)<br />

Mounting Clip<br />

12" LEAD LENGTHS<br />

2 1/8"<br />

3/16" DIA.<br />

CC-200<br />

MOUNTING CLIP<br />

LI555-IR<br />

5-50<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Ignitor Specifications<br />

(Case Temperature Rating 105° C)<br />

HID<br />

Metal Halide<br />

Ballast Data<br />

Metal Halide<br />

Standard Ignitor<br />

Long Range Ignitor<br />

<strong>Advance</strong><br />

Ballast<br />

Max.<br />

Lamp ANSI<br />

Catalog<br />

Case Catalog<br />

Min. Max.<br />

Case<br />

Ballast<br />

Circuit<br />

Dist. (ft.)<br />

Dist. (ft) Dist. (ft)<br />

Watts Code<br />

Number<br />

Type Number<br />

Type<br />

Family<br />

Type<br />

To Lamp<br />

To Lamp To Lamp<br />

}<br />

71A5105 50 M110/148 HX LI533-H4-IC 15 Round<br />

71A5181 50 M110/148 HX LI533-H4-IC 10 Round<br />

XTENZA ®<br />

71A5137 50 M110/148 R LI533-H4-IC 2 Round<br />

71A5205 70 M98/143 HX LI533-H4-IC 25 Round<br />

Wide-Range Ignitor<br />

71A52_2 70 M98/143 HX LI533-H4-IC 15 Round<br />

71A5237 70 M98/143 R LI533-H4-IC 10 Round<br />

71A52_1 70 M139 HX LI533-H4-IC 10 Round<br />

71A53_0 100 M90/140 HX LI533-H4-IC 20 Round<br />

71A5383 100 M90/140 CWA LI533-H4-IC 2 Round<br />

71A5337 100 M90/140 R LI533-H4-IC 2 Round<br />

71A54_2 150 M102/142 HX LI533-H4-IC 10 Round LI533-LR 0 - 50 ft Oval<br />

71A5437 150 M102/142 R LI533-H4-IC 2 Round<br />

71A55_3 175 M137/152 SuperCWA LI533-H4-IC 2 Oval<br />

71A56_2 200 M136 SuperCWA LI533-H4-IC 2 Round<br />

71A56_3 200 M136 SuperCWA LI533-H4-IC 5 Round<br />

71A57_2 250 M138/153 SuperCWA LI533-H4-IC 5 Round<br />

Meets ANSI pulse requirements<br />

71A58_2 320 M132/154 SuperCWA LI533-H4-IC 2 Round<br />

for all ballast to lamp distances<br />

71A59_3 350 M131 SuperCWA LI533-H4-IC 2 Round<br />

from 0 to 50 ft.<br />

71A60_2 400 M135/155 SuperCWA LI533-H4-IC 10 Round<br />

71A61E6 400 M135/155 SuperCWI LI533-H4-IC 2 Round<br />

Features 105°C case<br />

71A63_3 450 M144 Super CWA LI533-H4-IC 5 Round<br />

temperature rating<br />

71A55_4 175 M137/152 Reg Lag LI534-H5-IC 20 Oval<br />

}<br />

See Ordering Information Below<br />

71A5634 200 M136 Reg Lag LI534-H5-IC 2 Oval<br />

71A57_4 250 M138/153 Reg Lag LI533-H4-IC 2 Oval<br />

71A60_4 400 M128/135/155 Reg Lag LI534-H5-IC 10 Oval<br />

71A6334 450 M144 Reg Lag LI534-H5-IC 2 Oval LI533-LR3 ★ 0 - 50 ft Oval<br />

71A64_0 750 M149 SuperCWA LI573-H5 15 Oval<br />

71A64_2 750 M149 SuperCWA LI573-H5-IC 15 Oval<br />

71A64_8 875 M-TBD SuperCWA LI572-H5-IC★ 10 Oval<br />

71A65_1 1000 M141 SuperCWA LI572-H5-IC★ 10 Oval<br />

71A65_3 1000 M141 SuperCWA LI571-H5-IC★ 5 Oval<br />

71A50_5 35 M130 HX LI533-H4-IC 15 Round LI561-H5★ 15 50 Oval<br />

71A5081 35 M130 HX LI533-H4-IC 15 Round LI561-H5★ 15 50 Oval<br />

71A5037 35 M130 R LI533-H4-IC 10 Round LI561-H5★ 10 50 Oval<br />

71A52_0 70 M85 HX LI522-H5-IC★ 30 Oval<br />

Not Available<br />

71A54A3 150 M102/142 SuperCWA LI501-J4-IC★ 15 Round<br />

Not Available<br />

71A54_0 150 M81 HX LI522-H5-IC★ 20 Oval<br />

Not Available<br />

71A5486 150 M81 CWA LI523-H5-IC★ 2 Oval<br />

Not Available<br />

71A5880 250 M80 HX LI522-H5-IC★ 5 Oval<br />

Not Available<br />

71A86_5 750 ** CWA LI561-H5-IC★ 5 Oval<br />

Not Available<br />

71A69_0 2000 M134 CWA LI571-H5-IC★ 5 Oval LI571-J5★ 20 40 Oval<br />

**<br />

- Retrofit for S111<br />

★ Equipped with an auto-rest thermal protector to prevent<br />

ignitor from overheating in the event of lamp failure<br />

XTENZA Ordering Information<br />

To order in bulk, specify item no. LI533-LR or<br />

LI533-LR3. For individual carton, add -IC to item no.<br />

XTENZA is also available packaged with the ballasts<br />

shown at right.<br />

Includes core & coil ballast, capacitor and XTENZA.<br />

<strong>Ballasts</strong> are available with or without welded mounting<br />

bracket. Add appropriate suffix to ballast number.<br />

Round Case<br />

WHITE (X2)<br />

RED (X1)<br />

BLUE (X3)<br />

Round Case<br />

= 2"<br />

LI551-H4<br />

All Others= 2 1 /2"<br />

= 2 1 /8”<br />

All others 2 1 /2”<br />

1 1 /4" DIAMETER<br />

2 5 /32"<br />

Max. case temp. 90 o C<br />

Case must be grounded<br />

4 1 /4"<br />

4 3 /4"<br />

Oval Ignitor<br />

Case<br />

3"<br />

Oval Case<br />

1 5 /16"<br />

1/4" SLOT<br />

RED (X1)<br />

WHITE (X2)<br />

BLUE (X3)<br />

CC-125<br />

MOUNTING CLIP for Round Case (Furnished<br />

as standard with -001 suffix ballasts and all<br />

-IC suffix replacement ignitors.<br />

1"<br />

Lamp<br />

Watts<br />

ANSI<br />

Code<br />

Ballast<br />

Number<br />

50 M110/148 71A5105<br />

50 M110/148 71A5181<br />

70 M98/143 71A5205<br />

70 M98/143 71A5292<br />

70 M139 71A5281<br />

100 M90/140 71A5383<br />

100 M90/140 71A5390<br />

150 M102/142 71A5492<br />

175 M137/152 71A5593<br />

200 M136 71A5692<br />

250 M138/153 71A5792<br />

320 M132/154 71A5892<br />

350 M131 71A5993<br />

400 M135/155 71A6092<br />

450 M144 71A6393<br />

750 M149 71A64E2<br />

1000 M141 71A6593<br />

No<br />

Bracket<br />

-900DP<br />

-900D<br />

-900DP<br />

-900D<br />

-900D<br />

-900D<br />

-900D<br />

-900D<br />

-900D<br />

-900D<br />

-900D<br />

-900D<br />

-900D<br />

-900D<br />

-900D<br />

-900D<br />

-900<br />

With Welded<br />

Bracket<br />

-910DP<br />

-910D<br />

-910DP<br />

-910D<br />

-910D<br />

-910D<br />

-910D<br />

-910D<br />

-910D<br />

-910D<br />

-910D<br />

-910D<br />

-910D<br />

-910D<br />

-910D<br />

-910D<br />

-910<br />

HID • IGNITORS<br />

METAL HALIDE<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-51


HIGH INTENSITY DISCHARGE BALLASTS<br />

LISOD<br />

The <strong>Advance</strong> shut-off device (LISOD TM ) enhances the<br />

reliability of High Intensity Discharge (HID) lighting systems<br />

where ignitors are utilized to start the HID lamps. This includes<br />

all high pressure sodium lamps as well as all low, medium, and<br />

high wattage pulse-start metal halide lamps.<br />

The LISOD shut-off device increases the life of the ignitor by<br />

disabling it from the circuit and eliminates any concern over<br />

long-term ballast reliability due to continuously pulsing<br />

ignitors when a lamp is burned out. The LISOD provides a<br />

simple solution to eliminate lamp cycling typically associated<br />

with lamps that have reached their end of life. The LISOD<br />

disables the ignitor after 15 minutes of pulsing in cases when<br />

lamp is taken out of socket or lamp fails to ignite.<br />

> Compatible with any <strong>Advance</strong> Reactor (R), High-Reactance (HX),<br />

and Constant Wattage Autotransformer (CWA) ballast and ignitor<br />

circuit that includes a 120V input tap.<br />

> Integral timer automatically disables ignitor from ballast circuit<br />

15-minutes after power is applied to the ballast<br />

> Extends ignitor life, which is typically rated for 10,000 hours of<br />

continuous pulsing<br />

> Protects ballast coil insulation from potential damage due to a<br />

continuously pulsing ignitor<br />

> Prevents cycling of end-of-life lamps making identification for<br />

lamp replacement easy<br />

> Automatically resets/restarts itself after 0.6 second of power<br />

interruption (voltage dropout)<br />

Catalog<br />

Number<br />

Catalog<br />

Number<br />

Quantity<br />

Per Carton<br />

Lead Lengths are 12”<br />

VLINE<br />

LAMP<br />

LISOD1-IC<br />

Ignitor shut-off device for HID CWA, HX,<br />

and R ballasts with ignitors.<br />

Individual carton packaging<br />

1<br />

120V<br />

X3<br />

X1 LAMP<br />

IGNITOR<br />

X2 COM<br />

LISOD1<br />

Ignitor shut-off device for HID CWA,<br />

HX and R ballasts with ignitors.<br />

Bulk packaging<br />

50<br />

COM<br />

120V (RED)<br />

X2 COM (WHITE)<br />

LISOD<br />

COM (WHITE)<br />

COM<br />

HID • CORE & COIL<br />

Lamp Ignitors Square Plug-in<br />

Assemblies<br />

Square Plug-in ignitor assemblies for use by the HID<br />

fixture manufacturing community to help simplify the lighting<br />

maintenance process.<br />

Designed to make it easier to maintain, assemble, test,<br />

and replace ignitors in magnetic HID fixtures, the Square Plugin<br />

ignitor assembly is electrically identical to <strong>Advance</strong>'s standard<br />

ignitors (e.g., models LI501-H4, LI551-H4, or LI533-H4),<br />

but is housed in a special mechanical enclosure with 3 tab<br />

terminals. Offering added convenience and freedom of choice,<br />

<strong>Advance</strong>'s Square Plug-in ignitor assembly is designed for use<br />

anywhere that its standard ignitor packaging is placed, and<br />

serves as a direct replacement or enhanced alternative to the<br />

standard product for greater simplicity and ease of use.<br />

The following three Square Plug-in ignitor assemblies are<br />

currently available from <strong>Advance</strong>:<br />

> Square Plug-in ignitor assembly for high pressure sodium<br />

(HPS) lamps 150 Watts and up (100V) -- [catalog number<br />

LI501-SQR]<br />

> Square Plug-in ignitor assembly for 35-150 Watt (55V) high<br />

pressure sodium (HPS) lamps--[catalog number LI551-SQR]<br />

> Square Plug-in ignitor assembly for 50-400 Watt metal<br />

halide lamps (85 to 135V)--[catalog number LI533-SQR]<br />

Catalog<br />

Number<br />

LI5xxSQR<br />

Catalog<br />

Number<br />

Complete Ignitor and<br />

Receptacle Assembly<br />

Quantity<br />

Per Carton<br />

LI5xxSQ Ignitor only 70<br />

50<br />

5-52<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Ignitor Specifications<br />

(Case Temperature Rating 105° C)<br />

High Pressure Sodium<br />

High Pressure Sodium<br />

Ballast Data<br />

Standard Ignitor<br />

Long Range Ignitor<br />

<strong>Advance</strong><br />

Ballast<br />

Family<br />

Lamp<br />

Watts<br />

ANSI<br />

Code<br />

Ballast<br />

Circuit<br />

Type<br />

Catalog<br />

Number<br />

Max.<br />

Dist. (ft.)<br />

To Lamp<br />

Case<br />

Type<br />

Catalog<br />

Number<br />

Max.<br />

Dist. (ft.)<br />

To Lamp<br />

Case<br />

Type<br />

HID • IGNITORS<br />

HPS<br />

RED (X1)<br />

71A7707 35 S76 R LI551-H4-IC 2 Round LI551-J4-IC 15 Round<br />

71A77_5 35 S99 Hybrid 6C035-IC* 2 Rect Not Available<br />

71A7801 50 S68 HX LI551-H4-IC 2 Round LI551-J4-IC 35 Round<br />

71A7807 50 S68 R LI551-H4-IC 2 Round LI551-J4-IC 15 Round<br />

71A78_5 50 S104 Hybrid 6C050-IC* 2 Rect. Not Available<br />

71A79_0 70 S62 Reg Lag LI551-H4-IC 2 Round LI551-J4-IC 20 Round<br />

71A79_1 70 S62 HX LI551-H4-IC 2 Round LI551-J4-IC 35 Round<br />

71A79_6 70 S62 CWI LI551-J4-IC 2 Round Not Available<br />

71A79_8 70 S62 CWA LI551-J4-IC 5 Round Not Available<br />

71A7907 70 S62 R LI551-H4-IC 2 Round LI551-J4-IC 15 Round<br />

71A80_0 100 S54 Reg Lag LI551-H4-IC 2 Round LI551-J4-IC 35 Round<br />

71A80_1 100 S54 HX LI551-H4-IC 2 Round LI551-J4-IC 35 Round<br />

71A80_8 100 S54 CWA LI551-J4-IC 5 Round Not Available<br />

71A8007 100 S54 R LI551-H4-IC 2 Round LI551-J4-IC 15 Round<br />

71A80_6 100 S54 CWI LI551-J4-IC 2 Round Not Available<br />

71A80_5 100 S105 Hybrid 6C100-IC* 2 Rect. Not Available<br />

71A81_0 150 S55 Reg Lag LI551-H4-IC 2 Round LI551-J4-IC 40 Round<br />

71A81_2 150 S55 HX LI551-H4-IC 2 Round LI551-J4-IC 35 Round<br />

71A81_8 150 S55 CWA LI551-J4-IC 10 Round Not Available<br />

71A8107 150 S55 R LI551-H4-IC 2 Round LI551-J4-IC 15 Round<br />

71A8156 150 S55 CWI LI551-J4-IC 2 Round Not Available<br />

71A85_5 150 S55 CWI LI551-J4-IC 2 Round Not Available<br />

71A81_6 150 S56 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A86_7 150 S56 R LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

*<br />

- Case temperature rating is 80°C only.<br />

Round Case<br />

2 5 /32"<br />

Oval Ignitor<br />

Case<br />

3"<br />

Oval Case<br />

1 5 /16"<br />

RED (X1)<br />

WHITE (X2)<br />

BLUE (X3)<br />

WHITE (X2)<br />

Round Case<br />

1 1 /4" DIAMETER<br />

4 1 /4"<br />

4 3 /4"<br />

1"<br />

BLUE (X3)<br />

LI551-H4 = 2" 2 1 /8”<br />

All All Others= others 22 1 /2”<br />

1 /2"<br />

case temp. 90 o C<br />

must be grounded<br />

1/4" SLOT<br />

4 3 /16"<br />

White Son<br />

Controlle<br />

Rectangular<br />

Case<br />

CC-125<br />

MOUNTING CLIP for Round Case<br />

(Furnished as standard with -001<br />

suffix ballasts and all -IC suffix<br />

replacement ignitors.<br />

White SON<br />

Controller<br />

3 1 /16"<br />

emp. 80 o C<br />

e grounded.<br />

1 11 /16"<br />

5-53<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Ignitor Specifications<br />

(Case Temperature Rating 105° C)<br />

HID<br />

High Pressure Sodium<br />

High Pressure Sodium<br />

Ballast Data<br />

Standard Ignitor<br />

Long Range Ignitor<br />

<strong>Advance</strong><br />

Ballast<br />

Family<br />

Lamp<br />

Watts<br />

ANSI<br />

Code<br />

Ballast<br />

Circuit<br />

Type<br />

Catalog<br />

Number<br />

Max.<br />

Dist. (ft.)<br />

To Lamp<br />

Case<br />

Type<br />

Catalog<br />

Number<br />

Max.<br />

Dist. (ft.)<br />

To Lamp<br />

Case<br />

Type<br />

71A89_0 200 S66 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A89_1 200 S66 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A89_4 200 S66 Reg Lag LI501-H4-IC 2 Round LI501-J4-IC 40 Round<br />

71A89_7 200 S66 R LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A82_0 250 S50 Reg Lag LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A82_1 250 S50 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A82_6 250 S50 CWI LI501-J4-IC 2 Round Not Available<br />

71A82_7 250 S50 R LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A8392 250 S50 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A83_0 310 S67 Reg Lag LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A83_1 310 S67 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A83_7 310 S67 R LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A84_0 400 S51 Reg Lag LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A84_3 400 S51 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A84_6 400 S51 CWI LI501-J4-IC 2 Round Not Available<br />

71A84_7 400 S51 R LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />

71A85_6 430 n/a CWI LI501-H4-IC 15 Round LI501-J4-IC 35 Round<br />

71A85_5 600 S106 CWA LI561-H5-IC 5 Oval Not Available<br />

71A85_8 600 S106 CWI LI561-H5-IC 2 Oval Not Available<br />

71A86_5 750 S111 CWA LI561-H5-IC 5 Oval Not Available<br />

71A87_3 1000 S52 CWA LI571-H5-IC★ 15 Oval LI571-J5-IC★ 75 Oval<br />

★ Equipped with an auto-rest thermal protector to prevent<br />

ignitor from overheating in the event of lamp failure.<br />

RED (X1)<br />

Round Case<br />

2 5 /32"<br />

Oval Ignitor<br />

Case<br />

3"<br />

1 5 /16"<br />

Oval Case<br />

RED (X1)<br />

WHITE (X2)<br />

BLUE (X3)<br />

HID • IGNITORS<br />

HPS<br />

WHITE (X2)<br />

BLUE (X3)<br />

Round Case<br />

1 1 /4" DIAMETER<br />

Max. case temp. 90 o C<br />

Case must be grounded<br />

4 1 /4"<br />

4 3 /4"<br />

1/4" SLOT<br />

1"<br />

LI551-H4<br />

LI551-H4 =<br />

2"<br />

2 1 /8”<br />

All<br />

All<br />

Others=<br />

others 2 1 /2”<br />

1 /2"<br />

White Son<br />

Controller<br />

Rectangular Case<br />

4 3 /16"<br />

CC-125<br />

MOUNTING CLIP for Round Case<br />

(Furnished as standard with -001<br />

suffix ballasts and all -IC suffix<br />

replacement ignitors.<br />

3 1 /16"<br />

case temp. 80 o C<br />

must be grounded.<br />

1 11 /16"<br />

White SON Controller<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-54


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Transformers & Autotransformers<br />

Stepdown Transformers and Autotransformers<br />

Lamp Type<br />

Lamp<br />

Watts<br />

Input: Output<br />

(Volts)<br />

Catalog ✝<br />

Number<br />

Max.<br />

Input<br />

Current<br />

Max.<br />

Watt<br />

Input<br />

Max.<br />

V.A.<br />

Load<br />

Wiring<br />

Diagram<br />

Dimensions<br />

Fig A B<br />

Weight<br />

(lbs)<br />

TRANSFORMERS<br />

AUTOTRANSFORMERS<br />

Stepdown Transformers for 6 and 12 volt Halogen Lighting<br />

120 120:6.0 71A9325 1.3 156 120 T-1 1 1.2 2.5 3.8<br />

50<br />

71A9742 (-J) .6 50 50 T-1 9 (11) 1.3 2.5(3.3) 2.0(2.3)<br />

HALOGEN<br />

120:11.5<br />

75 71A9743 (-J) .8 81 75 T-1 9 (11) 1.5 2.8(3.5) 2.5(2.8)<br />

50/75 277:11.8 71A9833 (-J) .3/.4 60/86 75 T-1 9 (11) 1.5 2.8(3.5) 2.5(2.8)<br />

Stepdown Autotransformers for 120 volt Incandescent Lighting<br />

150<br />

71A9749 .6 150 150 T-2 9 1.5 2.7 2.3<br />

INCANDESCENT 200 277:115 71A9839 (-J) .8 199 200 T-2 9 (11) 2.2 3.8(4.2) 3.8(4.1)<br />

300 71A9741 (-J) 1.1 300 300 T-2 9 (11) 2.0 3.5(4.0) 3.5(3.8)<br />

Stepdown & Step-up Autotransformers for use with HID Reactor <strong>Ballasts</strong><br />

35/50/70<br />

71A9740 1.1 99 190 T-2 9 1.5 2.8 2.5<br />

277:120<br />

HIGH PRESSURE 100/150 71A9744 2.1 190 385 T-2 9 2.3 3.5 4.0<br />

SODIUM 35/50/70 347:120 71A9885 .9 100 190 T-2 9 1.7 3.9 4.5<br />

100/150 347:120/277 71A9862 1.7 200 395 T-2 9 2.7 3.9 4.5<br />

HPS WHITE SON 35<br />

71A9846 (-J) .4 50 110 T-2 9 (11) 1.8 3.1(3.8) 3.5(3.8)<br />

(See pages 5-32, 50 277:120 71A9847 (-J) .6 72 155 T-2 9 (11) 2.4 3.8(4.4) 4.0(4.3)<br />

5-33, 5-36) 100 71A9876 (-J) .9 125 265 T-2 4 (11) 1.9 2.6(3.9) 6.5(6.8)<br />

50<br />

71A9877 1.6 80 190 T-4 9 1.5 2.8 2.5<br />

METAL HALIDE<br />

70 120:277 71A9900 2.5 85 250 T-4 9 1.9 3.4 3.3<br />

100 71A9741 (-J) 2.4 125 300 T-4 9 (11) 2.0 3.5(4.0) 3.5(3.8)<br />

50/100/150 347:120/277 71A9862 (-J) 1.7 200 395 T-2 9 (11) 2.7 3.9(4.7) 4.5(4.8)<br />

✝ Ordering information:<br />

Add proper suffix to catalog number:<br />

-600 includes core and coil only<br />

-610 includes core and coil with welded bracket<br />

-J (available where shown) includes J-Box cover and auto-reset thermal protection. Refer to Figure 11.<br />

LINE V<br />

OUTPUT V<br />

INCANDESCENT<br />

LAMP<br />

B<br />

MAX.<br />

A<br />

2 13 /16"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

3 /4"<br />

B<br />

MAX.<br />

2 3 /16"<br />

B<br />

A<br />

A<br />

2 3 /16"<br />

4 Holes cleared for<br />

#6 thru-bolts<br />

2 5 /8" Fig. 9<br />

(2 5 /8" x 2 3 /16 Reactor Core )<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

LINE V<br />

OUTPUT V<br />

Fig. T-1<br />

2 13 /16"<br />

LINE V<br />

VOLTS<br />

LAMP<br />

REACTOR<br />

OUTPUT V<br />

INCANDESCENT<br />

LAMP<br />

BALLAST<br />

HID<br />

CAP (OPTIONAL)<br />

LAMP<br />

2 7 /16"<br />

3 1 /2" 3 15 /16"<br />

Fig. 1<br />

(3" x 4" core)<br />

2 1 /4"<br />

2 13 /16"<br />

3 3 /8" Fig. 4<br />

(2 13 /16 " x 3 3 /8 Reactor Core )<br />

COM<br />

COM<br />

COM<br />

COM<br />

Fig. T-2<br />

B<br />

2 3 / 16 "<br />

OUTPUT V<br />

VOLTS<br />

LAMP<br />

A<br />

1 27 / 32 "<br />

LINE V<br />

COM<br />

COM<br />

REACTOR<br />

BALLAST<br />

HID<br />

CAP (OPTIONAL)<br />

LAMP<br />

COM<br />

COM<br />

Fig. T-4<br />

1 / 2 "<br />

1 / 2 "-14<br />

STRAIGHT PIPETHREAD<br />

2 5 / 8 "<br />

Fig. 11<br />

J-Box Ballast<br />

1 13 / 16<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

4, 9 4.0 0.75 3.50 0.28<br />

5-55<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

F-Can <strong>Ballasts</strong>, Indoor, Outdoor Type 1<br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Mercury<br />

Input<br />

Voltage<br />

100 Watt Lamp, ANSI Code H38/H44<br />

72C2584-NP<br />

120/277<br />

1.0/.5 1.0/.5 .7/.3 118 245 3/2<br />

8.5<br />

72C2584-NP-001 CWA<br />

11.75 10.50 11.13<br />

✪ ✓ ✓<br />

120/347 72C25C4-NP 1.0/.4 1.0/.4 .4/.2 119 235 3/1 8.5<br />

✓<br />

125 Watt Lamp, ANSI Code H42 SOUND RATING B<br />

120/347 72C29C4-NP CWA 1.4/.5 1.4/.5 .4/.2 150 245 4/2 11.75 10.50 11.13 8.5 ✪<br />

✓<br />

175 Watt Lamp, ANSI Code H39 SOUND RATING B<br />

72C3084-NP<br />

120/277<br />

1.7/.8 1.7/.7 .7/.3 200 245 5/3<br />

10.5<br />

72C3084-NP-001 CWA<br />

11.75 10.50 11.13<br />

✪ ✓ ✓<br />

120/347 72C30C4-NP 1.7/.6 1.7/.6 .7/.3 5/2<br />

✓<br />

250 Watt Lamp, ANSI Code H37 SOUND RATING B<br />

120/277<br />

400 Watt Lamp, ANSI Code H33 SOUND RATING C<br />

120/277<br />

Catalog<br />

Number<br />

72C3584-NP<br />

72C3584-NP-001<br />

72C4083-NP<br />

72C4083-NP-001<br />

Circuit<br />

Type<br />

Operating<br />

Input Amps<br />

Starting<br />

Open<br />

Circuit<br />

Input<br />

Watts<br />

Nom.<br />

Open<br />

Circuit<br />

Voltage<br />

✝ Ordering information:<br />

Replacement ballasts in individual cartons indicated by bold type with suffix -001.<br />

Fuse<br />

Rating<br />

Amps<br />

Over-all Case<br />

Length Length<br />

All <strong>Advance</strong> dual-volt, F-can ballasts include auto-reset thermal protection for both taps.<br />

✪ Ballast to lamp distance is only limited by the size of the conductor between the ballast and the lamp. For proper wire<br />

size, see table on page 5-50 of this catalog.<br />

Mtg.<br />

Dim.<br />

Total<br />

Wt.<br />

(lbs)<br />

Max.<br />

Ballast to<br />

Lamp<br />

Distance (ft)<br />

Certifications<br />

SOUND RATING B<br />

CWA 2.5/1.1 2.5/1.1 1.1/.5 280 245 7/3 14.30 13.13 13.75 14.5 ✪ ✓ ✓<br />

CWA 3.9/1.7 3.6/1.6 1.1/.5 450 245 10/5 19.20 18.00 18.63 20.5 ✪ ✓ ✓<br />

2 ⁵⁄₈"<br />

3³⁄₁₆"<br />

CASE LENGTH<br />

MOUNTING<br />

OVERALL LENGTH<br />

LEAD LENGTHS 12"<br />

Wiring Diagram<br />

All lead lengths 12”<br />

HID • F-CAN<br />

2"<br />

⁵⁄₁₆" Slots<br />

F-Can Ballast<br />

Dimensions<br />

Accessories<br />

PKG-625<br />

Mounting Bracket Kit<br />

Includes (2) mounting brackets<br />

and (4) #10-32 screws with<br />

nuts and washers.<br />

PC-161<br />

Lead Cover (TeePee Type)<br />

PC-857<br />

Wiring Compartment<br />

For end mounting, includes<br />

(5) ⁷⁄₈” dia. knockouts. May be used<br />

with or without PC-625 Mtg. Brkt. Kit<br />

³⁄₈"<br />

2"<br />

4"<br />

4¹⁄₂"<br />

⁵⁄₈"<br />

I l d (2) i b k<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-56


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

F-Can <strong>Ballasts</strong>, Indoor, Outdoor Type 1<br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Metal Halide<br />

HID • F-CAN<br />

New<br />

New<br />

New<br />

New<br />

New<br />

New<br />

Nom.<br />

Max.<br />

Input Amps<br />

Fuse<br />

Total<br />

Certifications<br />

Input Catalog Circuit<br />

Input Open Over-all Case Mtg. Ballast to<br />

Rating<br />

Wt.<br />

Voltage Number Type<br />

Open<br />

Watts Circuit Length Length Dim.<br />

Lamp<br />

Operating Starting<br />

Amps<br />

(lbs)<br />

Circuit<br />

Voltage<br />

Distance (ft)<br />

35/39 Watt Lamp, ANSI Code M130 SOUND RATING B<br />

72C5005-NP<br />

120<br />

72C5005-NP-BLS* HX-HPF .5 .5 .8 49 230 2 8.50 7.31 7.90 4.0 5 ✓ ✓<br />

120/277 72C5081-NP HX-HPF .6/.3 .6/.3 1.0/.4 56 255 3/1 11.75 10.50 11.13 9.0 10 ✓ ✓<br />

50 Watt Lamp, ANSI Code M110 or M148 SOUND RATING B<br />

72C5181-NP<br />

✓ ✓<br />

120/277<br />

.7/.3 .8/.4 1.2/.5 72 254 3/2<br />

25<br />

72C5181-NP-001 HX-HPF<br />

11.75 10.50 11.13 9.0<br />

✓<br />

120/347 72C51C1-NP .6/.2 .5/.2 1.6/.6 67 277 4/2<br />

20 20 20<br />

70 Watt Lamp, ANSI Code M85 (Double-ended lamp) SOUND RATING B<br />

72C5280-NP<br />

120/277<br />

.9/.4 1.0/.5 1.7/.8<br />

10 ✓ ✓<br />

72C5280-NP-001 HX-HPF<br />

94 240 5/2 11.75 10.50 11.13 8.5<br />

120/347 72C52C0-NP .8/.3 1.0/.4 1.7/.6<br />

35 ✓<br />

70 Watt Lamp, ANSI Code M98 or M143 SOUND RATING B<br />

72C5282-NP<br />

10 ✓ ✓<br />

120/277 72C5282-NP-001 .9/.4 1.3/.6 1.6/.8<br />

4/2<br />

HX-HPF 94 255<br />

11.75 10.50 11.13 8.5<br />

72C5282-NP-900 • 50<br />

✓<br />

120/347 72C52C2-NP .9/.3 1.2/.4 1.7/.7 5/2 20<br />

✓<br />

70 Watt Lamp, ANSI Code M139 SOUND RATING B<br />

72C5281-NP<br />

5<br />

120/277<br />

.9/.4 1.0/.5 1.7/.8 94 240 5/2 11.75 10.50 11.13 8.5<br />

✓ ✓<br />

72C5281-NP-900 • HX-HPF<br />

50<br />

120/347 72C52C1-NP-900 • .8/.3 1.0/.4 1.7/.6 94 255 5/2 11.75 10.50 11.13 8.5 50 ✓ ✓<br />

100 Watt Lamp, ANSI Code M90 or M140 SOUND RATING B<br />

72C5381-NP<br />

15<br />

120/277 72C5381-NP-001 1.1/.5 2.2/1.0 2.4/1.1<br />

6/3<br />

✓ ✓<br />

HX-HPF 125 277<br />

11.75 10.50 11.13 11.0<br />

72C5381-NP-900 •<br />

50<br />

120/347 72C53C1-NP 1.1/.4 2.2/.8 2.4/.9 6/2 15<br />

✓<br />

150 Watt Lamp, ANSI Code M81 (Double-ended lamp) SOUND RATING B<br />

120/277 72C5481-NP<br />

1.6/.7 1.7/.8 3.7/1.6<br />

✓ ✓<br />

HX-HPF<br />

180 240 10/4 14.30 13.13 13.75 13.0 10<br />

120/347 72C54C1-NP 1.6/.6 1.7/.6 3.7/1.3<br />

✓<br />

150 Watt Lamp, ANSI Code M102 or M142 SOUND RATING B<br />

72C5482-NP<br />

5<br />

120/277<br />

1.6/.7 1.5/.8 3.7/1.6 180 277 10/4 14.30 13.13 13.75 13.0<br />

✓ ✓<br />

72C5482-NP-900 • HX-HPF<br />

50<br />

120/347 72C54C2-NP-900 • 1.6/.6 1.7/.6 3.7/1.3 180 240 10/4 14.30 13.13 13.75 13.0 50 ✓<br />

All <strong>Advance</strong> dual-volt, F-can ballasts include auto-reset thermal protection for both taps.<br />

* Ballast with suffix -BLS includes bottom leads with studs.<br />

✪ Ballast to lamp distance is only limited by the size of the conductor between the ballast and the lamp. For proper wire<br />

size, see table on page 5-50 of this catalog.<br />

Replacement ballasts in individual cartons indicated by bold type with suffix -001.<br />

Wiring Diagram<br />

• <strong>Ballasts</strong> with suffix -900 include integral XTENZA ® Wide-Range Ignitor for 50 ft. max. ballast to lamp distance. All lead lengths 12”<br />

CASE LENGTH<br />

CASE LENGTH<br />

5-57<br />

1 11 /16”<br />

1 11 /16”<br />

2 3 /8”<br />

⁵⁄₁₆" Slots<br />

OVERALL LENGTH<br />

MOUNTING<br />

LEAD LENGTHS 12"<br />

Dimensions<br />

(72C5005-NP)<br />

2 5 /8” ⁵⁄₈"<br />

2"<br />

3³⁄₁₆"<br />

⁵⁄₁₆" Slots<br />

MOUNTING<br />

OVERALL LENGTH<br />

LEAD LENGTHS 12"<br />

Dimensions<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

F-Can <strong>Ballasts</strong>, Indoor, Outdoor Type 1<br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Metal Halide<br />

Input<br />

Voltage<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Operating<br />

Input Amps<br />

Starting<br />

Open<br />

Circuit<br />

Input<br />

Watts<br />

Nom.<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

Amps<br />

Over-all Case<br />

Length Length<br />

Mtg.<br />

Dim.<br />

Total<br />

Wt.<br />

(lbs)<br />

Max.<br />

Ballast to<br />

Lamp<br />

Distance (ft)<br />

Certifications<br />

175/150 Watt Lamp, ANSI Code M57 or H39/M107 SOUND RATING B<br />

72C5581-NP<br />

120/277<br />

2.0/.9 2.0/.9 1.4/.7 205<br />

5/3<br />

✓ ✓<br />

72C5581-NP-001 CWA<br />

300<br />

11.75 10.50 11.13 12.0 ✪<br />

120/347 72C55C1-NP 1.9/.7 1.9/.7 1.7/.5 208 5/2<br />

✓<br />

175 Watt Lamp, ANSI Code M137 or M152 (Pulse-Start) SOUND RATING B<br />

72C5582-NP• Super<br />

120/277<br />

1.7/.8 .9/.4 2.2/.9 205 300 5/3 14.30 13.13 13.75 15.5 50 ✓ ✓<br />

72C5582-NP-001• CWA<br />

250 Watt Lamp, ANSI Code M58 or H37 SOUND RATING C<br />

120/277 72C5782-NP<br />

2.6/1.1 2.1/.9 2.1/.9<br />

8/4 16.70 15.50 16.13 16.0<br />

✓ ✓<br />

120/277 72C5782-NP-001 CWA<br />

290 300<br />

✪<br />

120/347 72C57C2-NP 2.5/.9 2.0/.7 2.0/.7 7/3 14.30 13.13 13.75 14.0 ✓<br />

250 Watt Lamp, ANSI Code M138 or M153 (Pulse-Start) SOUND RATING B<br />

72C5783-NP• Super<br />

120/277<br />

2.8/1.2 2.5/1.1 1.9/.8 290 300 8/3 16.70 15.50 16.13 18.0 50 ✓ ✓<br />

72C5783-NP-001• CWA<br />

320 Watt Lamp, ANSI Code M132 or M154 (Pulse-Start) SOUND RATING C<br />

72C5882-NP• Super<br />

120/277<br />

3.4/1.5 2.8/1.2 1.6/.7 370 270 8/3 19.20 18.00 18.63 21.0 50 ✓ ✓<br />

72C5882-NP-001• CWA<br />

350 Watt Lamp, ANSI Code M131 (Pulse-Start) SOUND RATING C<br />

72C5983-NP• Super<br />

120/277<br />

3.7/1.7 2.5/1.2 3.9/1.7 410 310 10/4 19.20 18.00 18.63 24.0 50 ✓ ✓<br />

72C5983-NP-001• CWA<br />

400 Watt Lamp, ANSI Code M59 or H33 SOUND RATING C<br />

72C6082-NP<br />

120/277<br />

CWA 3.9/1.7 3.3/1.4 3.9/1.7 460 310 10/5 19.20 18.00 18.63 22.5 ✪ ✓ ✓<br />

72C6082-NP-WC*<br />

400 Watt Lamp, ANSI Code M135 or M155 (Pulse-Start) SOUND RATING C<br />

120/277<br />

72C6182-NP•<br />

72C6182-NP-001•<br />

Super<br />

CWA<br />

4.1/1.8 2.9/1.3 3.9/1.7 465 310 10/4 19.20 18.00 18.63 24.0 50 ✓ ✓<br />

All <strong>Advance</strong> dual-volt, F-can ballasts include auto-reset thermal protection for both taps.<br />

✪ Ballast to lamp distance is only limited by the size of the conductor between the ballast and the lamp. For proper wire<br />

size, see table on page 5-50 of this catalog.<br />

Replacement ballasts in individual cartons indicated by bold type with suffix -001.<br />

* Ballast with suffix WC (white can) is rated for Type 2 Outdoor use.<br />

• Includes integral XTENZA ® Wide-Range Ignitor for 50 ft. max. ballast to lamp distance.<br />

HID • F-CAN<br />

Accessories<br />

PKG-625<br />

Mounting Bracket Kit<br />

Includes (2) mounting brackets<br />

and (4) #10-32 screws with<br />

nuts and washers.<br />

PC-161<br />

Lead Cover (TeePee Type)<br />

PC-857<br />

Wiring Compartment<br />

For end mounting, includes<br />

(5) ⁷⁄₈” dia. knockouts. May be used<br />

with or without PC-625 Mtg. Brkt. Kit<br />

³⁄₈"<br />

2"<br />

4"<br />

4¹⁄₂"<br />

⁵⁄₈"<br />

Includes (2) mounting brackets<br />

and (4) #10 32 screws with nuts<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-58


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

F-Can <strong>Ballasts</strong>, Indoor, Outdoor Type 1<br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

High Pressure Sodium<br />

Input<br />

Voltage<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Input Amps<br />

Operating Starting<br />

Open<br />

Circuit<br />

Input<br />

Watts<br />

Nom.<br />

Open<br />

Circuit<br />

Voltage<br />

50 Watt Lamp, ANSI Code S68 SOUND RATING B<br />

72C7884-NP<br />

120/277<br />

HX-HPF .7/.3 .7/.4 1.4/.7 65 120 4/2 11.75 10.50 11.13 11.0 15 ✓ ✓<br />

72C7884-NP-001<br />

Fuse<br />

Rating<br />

Amps<br />

Over-all Case<br />

Length Length<br />

Mtg.<br />

Dim.<br />

Total<br />

Wt.<br />

(lbs)<br />

Max.<br />

Ballast to<br />

Lamp<br />

Distance (ft)<br />

Certifications<br />

70 Watt Lamp, ANSI Code S62 SOUND RATING B<br />

72C7984-NP<br />

120/277<br />

.9/.4 1.0/.5 1.4/.7 90<br />

5/2<br />

✓ ✓<br />

72C7984-NP-001 HX-HPF<br />

120<br />

11.75 10.50 11.13 10.0 7<br />

120/347 72C79C4-NP .8/.3 .9/.3 1.4/.5 94 4/2 ✓<br />

100 Watt Lamp, ANSI Code S54 SOUND RATING B<br />

72C8084-NP<br />

120/277<br />

1.1/.5 1.5/.7 1.9/.8<br />

✓ ✓<br />

72C8084-NP-001 HX-HPF<br />

125 120 6/3 11.75 10.50 11.13 11.0 15<br />

120/347 72C80C4-NP 1.2/.4 1.7/.6 1.7/.6 ✓<br />

150 Watt Lamp, ANSI Code S55 (55-Volt Arc Tube) SOUND RATING B<br />

120/277 72C8185-NP<br />

1.7/.7 2.6/1.2 2.2/1.0<br />

✓ ✓<br />

HX-HPF<br />

185 120 8/4 14.30 13.13 13.75 14.0 5<br />

120/347 72C81C5-NP 1.7/.6 2.6/.9 2.2/.8<br />

✓<br />

150 Watt Lamp, ANSI Code S56 (100-Volt Arc Tube) SOUND RATING B<br />

120/277 72C8680-NP CWA 1.7/.7 1.5/.7 1.0/.4 185 186 5/3 14.30 13.13 13.75 14.0 5 ✓ ✓<br />

35 Watt Lamp, ANSI Code S99 (White SON-Philips) (Minimum starting temperature -30°C or -20°F) SOUND RATING B<br />

Hybrid<br />

120 72C7705-NP<br />

.4 .6 .9 45 120 3 11.75 10.50 11.13 6.0 2 ✓ ✓<br />

<strong>Electronic</strong><br />

50 Watt Lamp, ANSI Code S104 (White SON-Philips) (Minimum starting temperature -30°C or -20°F) SOUND RATING B<br />

Hybrid<br />

120 72C7805-NP<br />

.7 1.0 1.3 68 120 3 11.75 10.50 11.13 6.5 2 ✓ ✓<br />

<strong>Electronic</strong><br />

HID • F-CAN<br />

100 Watt Lamp, ANSI Code S105 (White SON-Philips) (Minimum starting temperature -30°C or -20°F) SOUND RATING B<br />

Hybrid<br />

120 72C8005-NP<br />

1.1 2.2 2.0 120 120 5 14.30 13.13 13.75 9.0 2 ✓ ✓<br />

<strong>Electronic</strong><br />

All <strong>Advance</strong> dual-volt, F-can ballasts include auto-reset thermal protection for both taps.<br />

Wiring Diagram<br />

Except for White SON<br />

All lead lengths 12”<br />

2 5 /8” ⁵⁄₈"<br />

3³⁄₁₆"<br />

CASE LENGTH<br />

MOUNTING<br />

OVERALL LENGTH<br />

LEAD LENGTHS 12"<br />

Replacement ballasts in individual cartons indicated by<br />

bold type with suffix -001.<br />

Wiring Diagram<br />

For White SON<br />

All lead lengths 12”<br />

Accessories<br />

PKG-625<br />

Mounting Bracket Kit<br />

Includes (2) mounting brackets<br />

and (4) #10-32 screws with<br />

nuts and washers.<br />

PC-161<br />

Lead Cover (TeePee Type)<br />

2"<br />

⁵⁄₁₆" Slots<br />

Dimensions<br />

PC-857<br />

Wiring Compartment<br />

For end mounting, includes<br />

(5) ⁷⁄₈” dia. knockouts. May be used<br />

with or without PC-625 Mtg. Brkt. Kit<br />

³⁄₈"<br />

2"<br />

4"<br />

4¹⁄₂"<br />

⁵⁄₈"<br />

Includes (2) mounting brackets<br />

and (4) #10 32 screws with nuts<br />

5-59<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Encapsulated Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Mercury<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Case<br />

Style<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(lbs)<br />

100 Watt Lamp, ANSI Code H38 SOUND RATING A<br />

120/208/<br />

240/277<br />

73B2591 CWA 125<br />

1.1/.6/<br />

.6/.5<br />

250<br />

✝ Ordering information:<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

• For CWA circuits, figure is operating current.<br />

3/2/<br />

2/2<br />

PC709-2 10 280 7C100M33-R D 8.3<br />

175 Watt Lamp, ANSI Code H39 SOUND RATING A<br />

120/208/<br />

240/277<br />

73B3092 CWA 200<br />

1.9/1.1/<br />

1.0/.9<br />

215<br />

5/3/<br />

3/2<br />

PC709-2 17.5 240 7C175M33-R D 8.3<br />

250 Watt Lamp, ANSI Code H37 SOUND RATING B<br />

120/208/<br />

240/277<br />

73B3592 CWA 285<br />

2.5/1.4/<br />

1.3/1.1<br />

250<br />

8/5/<br />

5/3<br />

PC709-4 22.5 280 7C225P30-R D 12.0<br />

400 Watt Lamp, ANSI Code H33 SOUND RATING B<br />

120/208/<br />

240/277<br />

73B4091 CWA 454<br />

3.9/2.2/<br />

2.0/1.7<br />

245<br />

10/8/<br />

5/5<br />

A<br />

A<br />

A<br />

A<br />

PC767-1 35 240 7C350P30-R D 14.0<br />

LINE V<br />

CAP<br />

CAP<br />

LAMP<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

Fig. A<br />

COM<br />

LAMP<br />

HID • ENCAPSULATED<br />

CORE & COIL<br />

SIDE LEAD EXIT<br />

DIMENSIONS<br />

Case<br />

Style<br />

Lead<br />

Exit<br />

A B C<br />

PC709-2 Side 4.6 3.4 3.6 2.0 5.25 6.0<br />

PC709-4 Side 4.6 4.4 3.6 2.0 5.25 6.0<br />

PC767-1 Side 5.4 5.0 3.8 2.0 6.0 6.75<br />

D<br />

E<br />

F<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-60


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Encapsulated Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Metal Halide<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Cap Catalog<br />

Number<br />

70 Watt Lamp, ANSI Code M98 Medium Base SOUND RATING A<br />

120/277 73B5282 HX-HPF 90 1.9/.8 255 4/2 K PC709-2 8 280 7C080L33-R D 9.0 LI533-H4 15<br />

100 Watt Lamp, ANSI Code M90 or M140 SOUND RATING A<br />

120/277<br />

73B5380 HX-HPF 129 2.6/1.2 280 6/3 K PC709-4 12 280 7C120M33-R D<br />

LI533-H4 20<br />

10.0<br />

73B5383 CWA 128 1.1/.5 222 3/2 M PC709-4 10 330 7C100M33-R D<br />

LI533-H4 2<br />

150 Watt Lamp, ANSI Code M102 (Medium Base) or M142 SOUND RATING A<br />

120/277 73B5482 HX-HPF 185 3.7/1.6 265 10/4 K PC709-4 16 280 7C160M33-R D 11.0 LI533-H4 10<br />

175 Watt Lamp, ANSI Code M57 or H39 SOUND RATING A<br />

120/208/<br />

1.8/1.1/<br />

5/3/<br />

73B5590 CWA 210<br />

305<br />

240/277<br />

.9/.8<br />

3/2<br />

A PC709-4 10 400 7C100M40-R D 12.0 — —<br />

120/<br />

1.8/<br />

5/<br />

73B55A0 CWA 210<br />

305<br />

277/347<br />

.8/.7<br />

2/2<br />

A PC709-4 10 400 7C100M40-R D 12.2 — —<br />

250 Watt Lamp, ANSI Code M58 or H37 SOUND RATING B<br />

120/208/<br />

2.5/1.4/<br />

8/5/<br />

73B5790 CWA 295<br />

300<br />

240/277<br />

1.3/1.1<br />

5/3<br />

A PC767-1 15 400 7C150P40-R D 15.0 — —<br />

120/<br />

2.5/<br />

8/<br />

73B57A0 CWA 295<br />

315<br />

277/347<br />

1.1/.9<br />

3/3<br />

A PC767-1 15 400 7C150P40-R D 15.2 — —<br />

Case<br />

Style<br />

Mfd<br />

Min<br />

Volt<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(lbs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

250 Watt Lamp, ANSI Code M138 or M153 (Pulse-Start) SOUND RATING B<br />

120/208/<br />

Super<br />

2.5/1.4/<br />

8/5/<br />

73B5792<br />

292<br />

270 M PC767-1 17 330 7C170M33-R D 16.0 LI533-H4 2<br />

240/277<br />

CWA<br />

1.3/1.1<br />

5/3<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

HID • ENCAPSULATED<br />

CORE & COIL<br />

320 Watt Lamp, ANSI Code M132 or M154 (Pulse-Start) SOUND RATING B<br />

120/208/<br />

Super<br />

3.3/1.9/<br />

8/6/<br />

73B5892<br />

368<br />

270 M PC767-3 21 345 7C210P34-R D 18.0 LI533-H4 2<br />

240/277<br />

CWA<br />

1.7/1.4<br />

5/3<br />

350 Watt Lamp, ANSI Code M131 (Pulse-Start) SOUND RATING B<br />

120/208/<br />

240/277<br />

73B5993<br />

Super<br />

CWA<br />

400<br />

3.4/2.0/<br />

1.7/1.5<br />

✝ Ordering information:<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-500 includes core & coil with oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

• For CWA circuits, figure is operating current. For HX circuits, figure is<br />

highest of starting, operating or open circuit currents.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />

Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />

is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />

for additional information.<br />

10/7/<br />

270 M PC767-3 23 345 7C225P34 D 18.0 LI533-H4 2<br />

5/5<br />

5-61<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Encapsulated Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Metal Halide<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max • Nom<br />

Fuse<br />

Open<br />

Input<br />

Rating<br />

Circuit<br />

Current (Amps)<br />

Voltage<br />

Wiring<br />

Dia<br />

Case<br />

Style<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Total<br />

Weight<br />

(lbs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

400 Watt Lamp, ANSI Code M59 or H33 SOUND RATING B<br />

120/208/<br />

240/277<br />

120/<br />

277/347<br />

73B6091 CWA 458<br />

73B60A1 CWA 460<br />

4.0/2.3/<br />

2.0/1.7<br />

4.0/<br />

1.7/1.4<br />

10/7/<br />

300 A PC767-3 24 400 7C240P40-R D 20.0 — —<br />

5/5<br />

10/<br />

300 A PC767-3 24 400 7C240P40-R D 20.2 — —<br />

5/4<br />

400 Watt Lamp, ANSI Code M135 or M155 (Pulse-Start) SOUND RATING B<br />

120/208/<br />

240/277<br />

10/7/<br />

265 M PC767-3 26 330 7C260P33-R D 18.0 LI533-H4 10<br />

5/5<br />

1000 Watt Lamp, ANSI Code M47 or H36 SOUND RATING C<br />

120/208/<br />

240/277<br />

120/208/<br />

277/347<br />

120/<br />

277/347<br />

73B6092<br />

Super<br />

CWA<br />

452<br />

73B6592 CWA 1080<br />

73B6590 CWA 1070<br />

73B65A2 CWA 1080<br />

3.8/2.2/<br />

1.9/1.7<br />

9.0/5.2/<br />

4.5/3.9<br />

9.0/<br />

3.9/3.2<br />

9.0/<br />

3.9/3.2<br />

Cap Catalog<br />

Number<br />

430<br />

20/15/<br />

10/10<br />

A PC768-2 24 480 MD2409-100 O 28.0 — —<br />

415<br />

20/<br />

10/8<br />

A PC768-2 26 480 MD2409-100 O 28.0 — —<br />

20/<br />

430 A PC768-1 24 480 MD2409-100 O 28.0 — —<br />

10/8<br />

Dry<br />

or<br />

Oil<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

✝ Ordering information:<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-500 includes core & coil with oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

• For CWA circuits, figure is operating current. For HX circuits, figure is<br />

highest of starting, operating or open circuit currents.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />

Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />

is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />

for additional information.<br />

COM<br />

CAP<br />

LINE V<br />

CAP<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

Fig. K<br />

LAMP<br />

X3<br />

IGNITOR<br />

X2<br />

COM<br />

X1<br />

LAMP<br />

LAMP<br />

DIMENSIONS<br />

Case<br />

Style<br />

Lead<br />

Exit<br />

A B C<br />

SIDE LEAD EXIT<br />

PC709-2 Side 4.6 3.4 3.6 2.0 5.25 6.0<br />

PC709-4 Side 4.6 4.4 3.6 2.0 5.25 6.0<br />

PC767-1 Side 5.4 5.0 3.8 2.0 6.0 6.75<br />

PC767-3 Side 5.4 5.0 4.3 2.0 6.0 6.75<br />

PC768-1 Side 6.5 5.0 5.2 2.0 7.0 7.75<br />

PC768-2 Side 6.3 4.9 5.9 2.0 7.0 7.75<br />

D<br />

E<br />

F<br />

HID • ENCAPSULATED<br />

CORE & COIL<br />

LINE V<br />

LINE V<br />

CAP<br />

CAP<br />

LAMP<br />

LINE V<br />

LINE V<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

LINE V<br />

LINE V<br />

CAP<br />

CAP<br />

CAP<br />

LINE V<br />

LAMP<br />

COM<br />

COM<br />

Fig. M<br />

COM<br />

COM<br />

Fig. A<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-62


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Encapsulated Core & Coil <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Case<br />

Style<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(lbs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

250 Watt Lamp, ANSI Code S50 SOUND RATING B<br />

120/277 73B8281 CWA 295 2.5/1.1 187 7/3 M PC767-3 35 240 7C350P24 D 15.0 LI501-H4 2<br />

400 Watt Lamp, ANSI Code S51 SOUND RATING B<br />

120/277 73B8483 CWA 460 3.8/1.7 190 10/5 M PC767-3 55 240 7C550P24 D 21.0 LI501-H4 2<br />

50 Watt Lamp, ANSI Code S104 (White SON-Philips) SOUND RATING A<br />

120 73B7805<br />

Hybrid<br />

<strong>Electronic</strong><br />

Reactor<br />

68 1.3 120 3 R PC709-6 28 120<br />

Dry capacitor & controller<br />

potted in can<br />

Internal 2<br />

100 Watt Lamp, ANSI Code S105 (White SON-Philips) SOUND RATING A<br />

120 73B8005<br />

Hybrid<br />

<strong>Electronic</strong><br />

Reactor<br />

120 2.2 120 5 R PC709-6 45 120<br />

Dry capacitor & controller<br />

potted in can<br />

9.0<br />

9.0<br />

Internal 2<br />

HID • ENCAPSULATED<br />

CORE & COIL<br />

✝ Ordering information:<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D (All except White SON) includes core & coil with dry-film capacitor<br />

-510 (White SON only) includes core and coil with dry-film capacitor and<br />

controller potted in can<br />

-600 (All except White SON) core & coil only (no capacitor)<br />

• For CWA circuits, figure is operating current. For Hybrid <strong>Electronic</strong> Reactor<br />

circuits, figure is highest of starting, operating or open circuit current.<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />

Range ignitor model shown for use within fixtures. If a Long Range ignitor is<br />

required for remote mounting, specify on order. See pages 5-50 to 5-53 for<br />

additional information.<br />

LINE V<br />

LINE V<br />

LAMP<br />

LINE V<br />

LINE V<br />

X3 X1<br />

IGNITOR<br />

X2<br />

LAMP<br />

COM<br />

CAP<br />

CAP<br />

CAP<br />

Fig. M<br />

COM<br />

END LEAD EXIT<br />

SIDE LEAD EXIT<br />

120 V<br />

CAP REACTOR<br />

NEUTRAL<br />

LAMP (RED) HV<br />

LAMP<br />

3<br />

CONTROLLER<br />

4<br />

LAMP (BLUE) LV<br />

Fig. R<br />

DIMENSIONS<br />

Case<br />

Style<br />

Lead<br />

Exit<br />

A B C D E F<br />

PC709-6 End 4.6 4.4 3.6 2.0 5.25 6.0<br />

PC709-7 End 4.6 3.4 3.6 2.0 5.25 6.0<br />

PC767-3 Side 5.4 5.0 4.3 2.0 6.0 6.75<br />

5-63<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Postline <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Mercury<br />

Input<br />

Volts<br />

Catalog Number<br />

(P=Thermally<br />

Protected)<br />

✝<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom. Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

(amps)<br />

Length<br />

(in)<br />

Spring Clip<br />

& Support<br />

Chain Kit<br />

Weight<br />

(lbs)<br />

Certifications<br />

50 Watt Lamp, ANSI Code H46<br />

120 74P1501-011P CWA 76 .7 250 2<br />

12.0<br />

PL-2<br />

(Optional)<br />

6.5<br />

✓<br />

✓<br />

120 74P1801-011 HX-NPF 74 2.0 275 5<br />

7.0<br />

PL-1<br />

(Optional)<br />

5.0<br />

✓<br />

✓<br />

75 Watt Lamp, ANSI Code H43<br />

120 74P2001-011P CWA 95 .9 240 2<br />

12.0<br />

PL-2<br />

(Optional)<br />

6.5<br />

✓<br />

✓<br />

120 74P2301-011 HX-NPF 92 2.1 250 6<br />

7.0<br />

PL-1<br />

(Optional)<br />

5.0<br />

✓<br />

✓<br />

100 Watt Lamp, ANSI Code H38<br />

120<br />

208<br />

240<br />

277<br />

74P2503-011P<br />

74P2513-011P<br />

74P2523-011P<br />

74P2533-011P<br />

CWA 122<br />

1.1<br />

.7<br />

.6<br />

.5<br />

250<br />

3<br />

2<br />

2<br />

2<br />

12.0<br />

PL-2<br />

(Included)<br />

6.5<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

120 74P2802-011 HX-NPF<br />

2.8 245 7<br />

120<br />

277 74P2832-011 R-NPF 1.4 277 4<br />

7.0<br />

PL-1<br />

(Included)<br />

PL-1<br />

(Included)<br />

5.0<br />

✓<br />

✓<br />

✓<br />

✓<br />

✝ Ordering information:<br />

Order catalog number indicated. <strong>Ballasts</strong> rated 100 watts and above include pre-assembled spring clip and support chain kit.<br />

For ballasts rated less than 100 watts, if spring clip and support chain kit is desired, order separately.<br />

• For CWA circuits, figure is operating current. For HX and R circuits, figure is highest of starting, operating or open circuit current.<br />

PHOTO<br />

CONTROL<br />

PHOTO*<br />

CONTROL<br />

BLACK<br />

GREEN<br />

GREEN<br />

GREEN<br />

GREEN<br />

TO<br />

FIXTURE<br />

FRAME<br />

TO<br />

FIXTURE<br />

BLACK<br />

FRAME<br />

RED<br />

RED<br />

INPUT<br />

VOLTS<br />

BLACK<br />

NPUT<br />

OLTS<br />

LACK<br />

WHITE<br />

WHITE<br />

BLUE<br />

COM<br />

WHITE<br />

OM<br />

HITE<br />

BLUE<br />

LAMP<br />

e: If Photo Control is not used,<br />

ect Red and Black leads together<br />

LAMP<br />

Postline Wiring Diagram<br />

Note: If Photo<br />

Control is not<br />

used, connect<br />

Red and Black<br />

leads together.<br />

PL-1 and PL-2 - Spring Clip and<br />

Support Chain Kits<br />

Included pre-assembled with all<br />

postline ballasts rated 100 watts<br />

and above. Support chain lowers<br />

ballast 18” down post while 6” or<br />

10” spring clip forces ballast<br />

against post’s inner wall to assure<br />

proper heat dissipation away from<br />

ballast’s internal components.<br />

Also includes factory-connected<br />

ground wire to provide for proper<br />

grounding of ballast case and fixture<br />

housing. Kits include instruction<br />

sheet and may be ordered<br />

separately to retrofit existing<br />

installations.<br />

18” Chain &<br />

Ground Wire<br />

¹₂” NPT - 14 Nipple<br />

Spring Clip:<br />

PL-1 6” for 7.0”<br />

long ballasts<br />

PL-2 10” for 12.0”,<br />

17.6”, 21.0”<br />

long ballasts<br />

2.55” dia.<br />

L<br />

HID • POSTLINE<br />

Postline Wiring Diagram<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-64


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Postline <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Mercury<br />

Input<br />

Volts<br />

Catalog Number<br />

(P=Thermally<br />

Protected)<br />

✝<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max<br />

•<br />

Input<br />

Current<br />

Nom. Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

(amps)<br />

Length<br />

(in)<br />

Spring Clip<br />

& Support<br />

Chain Kit<br />

Weight<br />

(lbs)<br />

Certifications<br />

175 Watt Lamp, ANSI Code H39<br />

120<br />

208<br />

240<br />

277<br />

74P3003-011P<br />

74P3013-011P<br />

74P3023-011P<br />

74P3033-011P<br />

CWA 215<br />

1.8<br />

1.1<br />

.9<br />

.9<br />

✝ Ordering information:<br />

Order catalog number indicated. <strong>Ballasts</strong> rated 100 watts and above include pre-assembled spring clip and support chain kit.<br />

• For CWA circuits, figure is operating current. For HX and R circuits, figure is highest of starting, operating or open circuit current.<br />

240<br />

5<br />

3<br />

3<br />

2<br />

PL-2<br />

(Included)<br />

175 HPS Watt Lamp, ANSI Code H39<br />

or 150 Watt Lamp, ANSI Code S63, EZ Lux (GE), Unalux (Osram Sylvania), Econolux (Philips), Retrolux (Philips)<br />

120<br />

208<br />

240<br />

277<br />

74P3303-011<br />

74P3313-011<br />

74P3323-011<br />

74P3333-011<br />

HX-NPF<br />

R-NPF<br />

250 Watt Lamp, ANSI Code H37<br />

120<br />

208<br />

240<br />

277<br />

74P3503-011P<br />

74P3513-011P<br />

74P3523-011P<br />

74P3533-011P<br />

210<br />

215<br />

205<br />

205<br />

CWA 300<br />

5.7<br />

2.8<br />

2.7<br />

2.5<br />

2.6<br />

1.5<br />

1.3<br />

1.2<br />

245<br />

245<br />

240<br />

277<br />

250<br />

15<br />

7<br />

7<br />

7<br />

7<br />

4<br />

4<br />

3<br />

12.0<br />

7.0<br />

7.0<br />

21.0<br />

PL-1<br />

(Included)<br />

PL-1<br />

(Included)<br />

PL-2<br />

(Included)<br />

6.5<br />

5.0<br />

5.0<br />

11.0<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

HID • POSTLINE<br />

PHOTO<br />

CONTROL<br />

PHOTO*<br />

CONTROL<br />

BLACK<br />

GREEN<br />

GREEN<br />

GREEN<br />

GREEN<br />

TO<br />

FIXTURE<br />

FRAME<br />

RED<br />

TO<br />

FIXTURE<br />

FRAME<br />

BLACK<br />

RED<br />

INPUT<br />

VOLTS<br />

BLACK<br />

INPUT<br />

VOLTS<br />

BLACK<br />

WHITE<br />

WHITE<br />

BLUE<br />

COM<br />

WHITE<br />

BLUE<br />

COM<br />

WHITE<br />

LAMP<br />

*Note: If Photo Control is not used,<br />

connect Red and Black leads together<br />

LAMP<br />

Postline Wiring Diagram<br />

Note: If Photo<br />

Control is not<br />

used, connect<br />

Red and Black<br />

leads together.<br />

PL-1 and PL-2 - Spring Clip and<br />

Support Chain Kits<br />

Included pre-assembled with all<br />

postline ballasts rated 100 watts<br />

and above. Support chain lowers<br />

ballast 18” down post while<br />

6” or 10” spring clip forces ballast<br />

against post’s inner wall to<br />

assure proper heat dissipation<br />

away from ballast’s internal<br />

components. Also includes factory-connected<br />

ground wire to<br />

provide for proper grounding of<br />

ballast case and fixture housing.<br />

Kits include instruction sheet<br />

and may be ordered separately<br />

to retrofit existing installations.<br />

18” Chain &<br />

Ground Wire<br />

¹₂” NPT - 14 Nipple<br />

Spring Clip:<br />

PL-1 6” for 7.0”<br />

long ballasts<br />

PL-2 10” for 12.0”,<br />

17.6”, 21.0”<br />

long ballasts<br />

L<br />

Postline Wiring Diagram<br />

2.55” dia.<br />

5-65<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Postline <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Metal Halide<br />

Input<br />

Volts<br />

Catalog Number<br />

(P=Thermally<br />

Protected)<br />

✝<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom. Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

(amps)<br />

Length<br />

(in)<br />

Weight<br />

(lbs)<br />

Spring Clip<br />

& Support<br />

Chain Kit<br />

Max Dist<br />

To Lamp<br />

(ft)<br />

Certifications<br />

50 Watt Lamp, ANSI Code M110<br />

120<br />

74P5103-011<br />

74P5104-011P<br />

HX-NPF<br />

HX-PFC<br />

69<br />

1.8<br />

1.1<br />

260<br />

5<br />

3<br />

12.0<br />

6.0<br />

PL-2<br />

(Optional)<br />

20<br />

✓<br />

✓<br />

✓<br />

✓<br />

✝ Ordering information:<br />

Order catalog number indicated. If spring clip and support chain kit is desired,<br />

order separately.<br />

• For HX circuit, figure is highest of starting, operating or open circuit current.<br />

PHOTO<br />

CONTROL<br />

PHOTO*<br />

CONTROL<br />

BLACK<br />

GREEN<br />

GREEN<br />

GREEN<br />

GREEN<br />

TO<br />

FIXTURE<br />

FRAME<br />

TO<br />

FIXTURE<br />

FRAME<br />

RED<br />

BLACK<br />

RED<br />

INPUT<br />

VOLTS<br />

BLACK<br />

INPUT<br />

VOLTS<br />

BLACK<br />

WHITE<br />

WHITE<br />

BLUE<br />

COM<br />

WHITE<br />

COM<br />

WHITE<br />

BLUE<br />

LAMP<br />

*Note: If Photo Control is not used,<br />

connect Red and Black leads together<br />

LAMP<br />

Postline Wiring Diagram<br />

Note: If Photo<br />

Control is not<br />

used, connect<br />

Red and Black<br />

leads together.<br />

PL-1 and PL-2 - Spring Clip and<br />

Support Chain Kits<br />

Included pre-assembled with all<br />

postline ballasts rated 100 watts<br />

and above. Support chain lowers<br />

ballast 18” down post while<br />

6” or 10” spring clip forces ballast<br />

against post’s inner wall to<br />

assure proper heat dissipation<br />

away from ballast’s internal<br />

components. Also includes factory-connected<br />

ground wire to<br />

provide for proper grounding of<br />

ballast case and fixture housing.<br />

Kits include instruction sheet<br />

and may be ordered separately<br />

to retrofit existing installations.<br />

18” Chain &<br />

Ground Wire<br />

¹₂” NPT - 14 Nipple<br />

Spring Clip:<br />

PL-1 6” for 7.0”<br />

long ballasts<br />

PL-2 10” for 12.0”,<br />

17.6”, 21.0”<br />

long ballasts<br />

L<br />

HID • POSTLINE<br />

Postline Wiring Diagram<br />

2.55” dia.<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-66


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Postline <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog Number✝<br />

(P=Thermally<br />

Protected)<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max<br />

•<br />

Input<br />

Current<br />

Nom. Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

(amps)<br />

Length<br />

(in)<br />

Weight<br />

(lbs)<br />

Spring Clip<br />

& Support<br />

Chain Kit<br />

Max Dist<br />

To Lamp<br />

(ft)<br />

Certifications<br />

HID • CORE & COIL<br />

HPS<br />

35 Watt Lamp, ANSI Code S76<br />

74P7702-011 R-NPF<br />

120<br />

74P7703-011P R-HPF<br />

✝ Ordering information:<br />

Order catalog number indicated. <strong>Ballasts</strong> rated 100 watts<br />

and above include pre-assembled spring clip and support<br />

chain kit. For ballasts rated less than 100 watts, if spring<br />

clip and support chain kit is desired, order separately.<br />

* 70 watt High Pressure Sodium ballasts with 208, 240, or<br />

277 Volt inputs will always be supplied with the spring clip<br />

and chain kit.<br />

• For CWA circuits, figure is operating current. For HX and R<br />

circuits, figure is highest of starting, operating or open circuit<br />

current.<br />

PL-1 and PL-2 - Spring Clip and Support Chain Kits<br />

Included pre-assembled with all postline ballasts rated 100<br />

watts and above. Support chain lowers ballast 18” down post<br />

while 6” or 10” spring clip forces ballast against post’s inner wall<br />

to assure proper heat dissipation away from ballast’s internal<br />

components. Also includes factory-connected ground wire to<br />

provide for proper grounding of ballast case and fixture housing.<br />

Kits include instruction sheet and may be ordered separately<br />

to retrofit existing installations.<br />

43<br />

50 Watt Lamp, ANSI Code S68<br />

120 74P7802-011 R-PFC 61<br />

120<br />

1.2<br />

.8<br />

74P7803-011P R-HPF 61 1.3 120 4 12.0 4.8<br />

70 Watt Lamp, ANSI Code S62<br />

120 74P7902-011 R-NPF 84<br />

120<br />

208<br />

240<br />

277<br />

74P7913-011P<br />

74P7923-011P<br />

74P7933-011P<br />

HX-HPF 97<br />

100 Watt Lamp, ANSI Code S54<br />

120<br />

208<br />

240<br />

277<br />

74P8002-011<br />

74P8003-011P<br />

74P8013-011P<br />

74P8023-011P<br />

74P8033-011P<br />

R-NPF<br />

R-HPF<br />

122<br />

HX-HPF 136<br />

120<br />

1.8 120<br />

.9<br />

.8<br />

.7<br />

3.1<br />

2.5<br />

1.1<br />

1.0<br />

.9<br />

150 Watt Lamp, ANSI Code S55 (55-Volt Arc Tube)<br />

74P8103-011 R-NPF<br />

4.6<br />

120<br />

178<br />

74P8104-011P R-HPF<br />

3.6<br />

2.2 120<br />

208<br />

240<br />

277<br />

120<br />

208<br />

240<br />

277<br />

120<br />

3<br />

2<br />

3.0<br />

3.5<br />

5 7.0 3.5<br />

74P7903-011P R-PFC 84 1.6 120 4 12.0 5.0<br />

18” Chain &<br />

Ground Wire<br />

¹₂” NPT -<br />

14 Nipple<br />

Spring Clip:<br />

PL-1<br />

6” for 7.0”<br />

long ballasts<br />

PL-2<br />

10” for 12.0”,<br />

17.6”, 21.0”<br />

long ballasts<br />

2.55” dia.<br />

6 7.0 3.5<br />

2<br />

2<br />

2<br />

8<br />

7<br />

3<br />

3<br />

3<br />

12<br />

9<br />

7.0<br />

17.6<br />

12.0<br />

17.6<br />

21.0<br />

12.0<br />

17.6<br />

8.5<br />

5.5<br />

7.3<br />

12.7<br />

6.0<br />

7.8<br />

L<br />

PL-1<br />

(Optional)<br />

PL-1<br />

(Optional)<br />

PL-2<br />

(Optional)<br />

PL-1<br />

(Optional)<br />

PL-2<br />

(Optional)<br />

PL-2*<br />

(Included)<br />

PL-2<br />

(Included)<br />

PL-2<br />

(Included)<br />

PL-2<br />

(Included)<br />

PHOTO<br />

CONTROL<br />

PHOTO*<br />

CONTROL<br />

BLACK<br />

GREEN<br />

GREEN<br />

GREEN<br />

GREEN<br />

TO<br />

FIXTURE<br />

FRAME<br />

TO<br />

FIXTURE<br />

FRAME<br />

RED<br />

BLACK<br />

RED<br />

INPUT<br />

VOLTS<br />

BLACK<br />

10<br />

10<br />

10<br />

10<br />

10<br />

10<br />

5<br />

5<br />

5<br />

INPUT<br />

VOLTS<br />

BLACK<br />

WHITE<br />

WHITE<br />

BLUE<br />

COM<br />

WHITE<br />

BLUE<br />

COM<br />

WHITE<br />

Postline Wiring Diagram<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

LAMP<br />

*Note: If Photo Control is not used,<br />

connect Red and Black leads together<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

LAMP<br />

Postline Wiring Diagram<br />

Note: If Photo<br />

Control is not<br />

used, connect<br />

Red and Black<br />

leads together.<br />

5-67<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Indoor Enclosed <strong>Ballasts</strong><br />

HID<br />

Mercury/HPS<br />

High Pressure Sodium<br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Maximum<br />

Ambient<br />

Temp.<br />

( )<br />

Watts<br />

Input<br />

Max<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

(amps)<br />

Weight<br />

(Ibs)<br />

200 Watt Lamp, ANSI Code S66<br />

CWA<br />

480 78E8940-001<br />

240 0.6 185 3 IE-1 PC-724 31<br />

(50 C)<br />

•<br />

Wiring<br />

Dia.<br />

Case<br />

Style<br />

Certification<br />

✓<br />

LAMP<br />

LAMP<br />

TO LINE<br />

COM<br />

TOP<br />

Fig. IE-1<br />

LINE V<br />

INSULATE UNUSED<br />

LAMP LEADS<br />

INDIVIDUALLY FOR 600V FOR 600V<br />

COM<br />

250 Watt Lamp, ANSI Code S50<br />

120/208/<br />

CWA<br />

78E8291-001<br />

295<br />

240/277<br />

(50 C)<br />

400 Watt Lamp, ANSI Code S51<br />

120/208/<br />

78E8493-001 CWA<br />

240/277<br />

464<br />

(40 C)<br />

480 78E8443-001<br />

1000 Watt Lamp, ANSI Code S52<br />

120/208/<br />

240/277<br />

480<br />

78E8793-001<br />

78E8743-001<br />

CWA<br />

(Protected★)<br />

(40 C)<br />

1100<br />

2.5/1.5/<br />

1.3/1.1<br />

3.8/2.2/<br />

1.9/1.7<br />

1.0<br />

9.5/5.5/<br />

4.8/4.2<br />

2.3<br />

187<br />

190<br />

435<br />

7/4/<br />

4/3<br />

10/8/<br />

5/5<br />

3<br />

25/15/<br />

10/10<br />

6<br />

IE-2<br />

IE-2<br />

IE-1<br />

IE-2<br />

IE-1<br />

PC-724 34<br />

PC-724 38<br />

PC-746 60<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

LAMP<br />

LAMP<br />

COM<br />

TOP<br />

Fig. IE-2<br />

INSULATE UNUSED<br />

INSULATE LAMP UNUSED LEAD<br />

LAMP FOR LEADS 600V<br />

INDIVIDUALLY FOR 600V<br />

COM<br />

COM<br />

120 V<br />

208 V<br />

240 V<br />

277 V<br />

Note: <strong>Ballasts</strong> must be mounted at least 12” apart. All indoor enclosed high pressure<br />

sodium and pulse-start metal halide lamp ballasts are furnished with an <strong>Advance</strong> long<br />

life ignitor built into the ballast can. Maximum lamp-to-ballast distance is 50 ft.<br />

(Except 1000 watt ballasts which are 75 ft). For ballasts not requiring ignitors,<br />

see page 5-50 for remote mounting considerations.<br />

• For CWA circuits, figure is operating current.<br />

★ Equipped with an auto-reset thermal protector to prevent ignitor from overheating in the<br />

event of lamp failure.<br />

Please see Metal Halide <strong>Section</strong> for Indoor Enclosed <strong>Ballasts</strong><br />

78E<br />

R ENCLOSED<br />

MENSIONS<br />

3 /8" Oval Slots<br />

F<br />

Top view<br />

3 double<br />

7 /8" and 1 1 /8"<br />

knockouts<br />

HID<br />

INDOOR ENCLOSED<br />

A B C D<br />

G<br />

E<br />

DIMENSIONS<br />

Case<br />

Style<br />

A B C D E<br />

PC-723 11³₈ 12 12³₄ 13³₄ 3⁵₁₆<br />

PC-724 12¹₁₆ 12¹¹₁₆ 13⁷₁₆ 14⁷₁₆ 3⁵₁₆<br />

PC-746 17³₈ 18 18³₄ 19³₄ 3⁵₁₆<br />

F<br />

6⁹₁₆<br />

7¹¹₁₆<br />

7¹¹₁₆<br />

G<br />

4³₄<br />

5³₄<br />

5³₄<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-68


HIGH INTENSITY DISCHARGE BALLASTS<br />

Outdoor Weatherproof <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Mercury<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max<br />

•<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

(amps)<br />

Wiring<br />

Dia.<br />

Height<br />

(in)<br />

Weight<br />

(Ibs)<br />

Certification<br />

100 Watt Lamp, ANSI Code H38 or H44<br />

120/208/<br />

240/277<br />

79W2591-001 CWA 125<br />

1.1/.6/<br />

.6/.5<br />

250<br />

3/2/<br />

2/2<br />

OW-2<br />

6.6 10<br />

✓<br />

✓<br />

250 Watt Lamp, ANSI Code H37<br />

120/208/<br />

240/277<br />

480<br />

79W3592-001<br />

79W3542-001<br />

CWA 285<br />

2.5/1.5/<br />

1.3/1.1<br />

.7<br />

250<br />

8/5/<br />

5/3<br />

2<br />

OW-2<br />

OW-1<br />

6.6 13<br />

✓<br />

✓<br />

✓<br />

✓<br />

• For CWA circuits, figure is operating current.<br />

LAMP COM COM LINE V<br />

TO LINE<br />

LAMP<br />

COM<br />

120 LINE V 208 LINE V 240 LINE V 277 LINE V<br />

Fig. OW-1<br />

TO LINE<br />

Fig. OW-2<br />

HID • OUTDOOR<br />

WEATHERPROOF<br />

SH-1 (without a hose clamp)<br />

Not included with ballast. Available at<br />

no charge when ordered with ballast.<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-69


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

Outdoor Weatherproof <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />

Metal Halide<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

(amps)<br />

Wiring<br />

Dia.<br />

Height<br />

(in)<br />

Weight<br />

(Ibs)<br />

Certification<br />

175/150 Watt Lamp, ANSI Code M57/M107 or H39<br />

120/208/<br />

240/277<br />

79W5590-001 CWA 210<br />

250 Watt Lamp, ANSI Code M58 or H37<br />

120/208/<br />

240/277<br />

79W5790-001 CWA 285<br />

1.8/1.1/<br />

.9/.8<br />

2.5/1.5/<br />

1.3/1.1<br />

305<br />

310<br />

5/3/<br />

3/2<br />

8/5/<br />

5/3<br />

OW-2<br />

OW-2<br />

6.6 15<br />

8.6 18<br />

400 Watt Lamp, ANSI Code M59 or H33<br />

120/208/<br />

4.0/2.3/<br />

10/7/<br />

79W6091-001<br />

458<br />

OW-2<br />

240/277<br />

CWA<br />

2.0/1.8 300 5/5<br />

8.6 21 ✓ ✓<br />

480 79W6041-001<br />

462 1.0<br />

4 OW-1<br />

✓ ✓<br />

Two 400 Watt Lamps, ANSI Code M59 or H33<br />

120/240 79W6351-001<br />

CWA<br />

8.4/4.2<br />

25/15<br />

✓ ✓<br />

890<br />

330 OW-4 13.8 43<br />

480 79W6341-001<br />

(ILO)<br />

2.1 7 ✓ ✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

LAMP COM COM LINE V<br />

TO LINE<br />

Fig. OW-1<br />

LAMP COM 120 LINE V 208 LINE V 240 LINE V 277 LINE V<br />

TO LINE<br />

Fig. OW-2<br />

1000 Watt Lamp, ANSI Code M47 or H36<br />

120/208/<br />

240/277<br />

480<br />

79W6592-001<br />

79W6542-001<br />

CWA 1080<br />

9.0/5.2/<br />

4.5/3.9<br />

2.3<br />

430<br />

20/15/<br />

10/10<br />

6<br />

OW-2<br />

OW-1<br />

11.3 33<br />

✓<br />

✓<br />

✓<br />

✓<br />

NSULATE UNUSED<br />

ALTERNATE LAMP<br />

EADS INDIVIDUALLY<br />

FOR 600V<br />

HID • OUTDOOR<br />

WEATHERPROOF<br />

1500 Watt Lamp, ANSI Code M48<br />

120/208/<br />

79W6792-001<br />

1605<br />

240/277<br />

CWA<br />

480 79W6742-001<br />

1625<br />

• For CWA circuits, figure is operating current.<br />

13.5/7.8/<br />

6.8/5.9<br />

3.4<br />

450<br />

30/25/<br />

20/15<br />

10<br />

OW-2<br />

OW-1<br />

13.8<br />

41<br />

40<br />

✓<br />

✓<br />

✓<br />

✓<br />

LAMP 1 COM LAMP 2 COM LINE V LINE V<br />

TO LINE<br />

Fig. OW-4<br />

SH-1 (without a hose clamp)<br />

Not included with ballast. Available at<br />

no charge when ordered with ballast.<br />

5-70<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

Outdoor Weatherproof <strong>Ballasts</strong><br />

(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />

HID<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Catalog<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

(amps)<br />

Wiring<br />

Dia.<br />

Height<br />

(in)<br />

Weight<br />

(Ibs)<br />

Certification<br />

150 Watt Lamp, ANSI Code S55 (55-Volt Arc Tube)<br />

120/208/<br />

240/277<br />

79W8192-001 HX-HPF 188<br />

250 Watt Lamp, ANSI Code S50<br />

120/208/<br />

79W8291-001<br />

240/277<br />

CWA 310<br />

480 79W8241-001<br />

2.8/1.6/<br />

1.4/1.3<br />

2.5/1.5/<br />

1.3/1.1<br />

0.7<br />

All weatherproof high pressure sodium lamp ballasts are furnished with an <strong>Advance</strong> long life ignitor built<br />

into the ballast can. Maximum lamp-to-ballast distance is 50 ft. (except 79W8192 - distance is 35 ft and<br />

1000 watt ballasts which are 75 ft.)<br />

• For CWA circuits, figure is operating current. For HX circuits, figure is highest of starting, operating or open<br />

circuit current.<br />

★ Equipped with an auto-reset thermal protector to prevent ignitor from overheating in the event of lamp failure.<br />

120<br />

10/5/<br />

5/4<br />

OW-2 8.6 12 ✓ ✓<br />

310 Watt Lamp, ANSI Code S67<br />

240/480 79W9597-001 CWA 365 1.7/.9 175 5/3 OW-2 11.3 17<br />

400 Watt Lamp, ANSI Code S51<br />

120/208/<br />

240/277<br />

480<br />

79W8493-001<br />

79W8443-001<br />

CWA 464<br />

1000 Watt Lamp, ANSI Code S52<br />

120/208/<br />

240//277<br />

480<br />

79W8793-001<br />

79W8743-001<br />

CWA<br />

(Protected)<br />

★<br />

1100<br />

3.8/2.2<br />

1.9/1.7<br />

1.0<br />

9.5/5.5/<br />

4.8/4.2<br />

2.3<br />

187<br />

190<br />

435<br />

7/4/<br />

4/3<br />

2<br />

10/8/<br />

5/5<br />

3<br />

25/15/<br />

10/10<br />

6<br />

OW-2<br />

OW-1<br />

OW-2<br />

OW-1<br />

OW-2<br />

OW-1<br />

11.3<br />

14<br />

17<br />

11.3 20<br />

13.8 34<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

LAMP COM COM LINE V<br />

TO LINE<br />

Fig. OW-1<br />

LAMP COM 120 LINE V 208 LINE V 240 LINE V 277 LINE V<br />

TO LINE<br />

Fig. OW-2<br />

HID • OUTDOOR<br />

WEATHERPROOF<br />

SH-1 (without a hose clamp)<br />

Not included with ballast. Available at<br />

no charge when ordered with ballast.<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

5-71


SPECIALTY PRODUCTS<br />

Contents<br />

Specialty Fluorescent and HID <strong>Ballasts</strong> and LED Drivers<br />

Residential Lighting ............................................................................6-4<br />

<strong>Ballasts</strong> that meet FCC Consumer limits and can be used in<br />

Energy Star Fixtures<br />

UV Disinfection....................................................................................6-5<br />

Ballast for Germicidal/UV lamps<br />

Refrigeration, Tanning and Display Lighting......................................6-6<br />

<strong>Ballasts</strong> for T8 and T12/HO lamps<br />

Ballast Dimensions and Wiring Diagrams..................................6-7 to 6-8<br />

International <strong>Ballasts</strong> (Locations other than North America)<br />

High Frequency <strong>Electronic</strong> Fluorescent <strong>Ballasts</strong><br />

General Information ........................................................................6-9<br />

<strong>Ballasts</strong> for Rapid Start, HO & CFL Lamps .......................6-10 to 6-12<br />

Electromagnetic Fluorescent <strong>Ballasts</strong><br />

General Information ......................................................................6-13<br />

<strong>Ballasts</strong> for Rapid Start, HO, Slimline & Preheat Lamps ..6-14 to 6-17<br />

Electromagnetic HID <strong>Ballasts</strong><br />

General Information ......................................................................6-18<br />

50 Hz Core & Coil for <strong>Ballasts</strong>..........................................6-19 to 6-21<br />

Mercury - Metal Halide - High Pressure Sodium lamps<br />

60 Hz Core & Coil (Southern Japan).............................................6-22<br />

Mercury - Metal Halide<br />

50 Hz Core & Coil (Northern Japan) .............................................6-23<br />

Mercury - Metal Halide<br />

LED <strong>Electronic</strong> Drivers<br />

Xitanium TM LED Drivers for Europe ......................................................6-24<br />

Corporate Offices<br />

(800) 322-2086<br />

Customer Support/Technical Service<br />

(800) 372-3331 • (+) 1 847 390-5000 (Specialty)<br />

SPECIALTY<br />

Visit our web site at www.advancetransformer.com<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 6-1


RESIDENTIAL BALLASTS<br />

Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - AmbiStar <br />

<strong>Electronic</strong> <strong>Ballasts</strong> for 4-pin Compact Fluorescent and T5, T8 or T12 Linear Lamps<br />

<strong>Advance</strong>'s family of electronic ballasts specifically designed for popular fluorescent applications<br />

in homes and other non-commercial environments brings all of the energy-efficient benefits of<br />

fluorescent lighting to residential and hospitality applications. FCC Class B EMI compliant and<br />

available for T5 linear (8-14W), T8 linear (17-32W), T12 linear (34W-40W) and 4-pin CFL lamps.<br />

<strong>Advance</strong>'s AmbiStar ballasts are compact and lightweight, provide quick starting and save users<br />

significant energy costs relative to alternative lighting sources.<br />

Features<br />

Less than 1.0 second starting<br />

<strong>Electronic</strong> design<br />

Class B FCC EMI Rating meets Energy Star<br />

and consumer EMI requirements<br />

End-of-Lamp life protection for T5 lamps<br />

and smaller<br />

Benefits<br />

Provides flicker-free starting<br />

Increased energy savings over incandescent and<br />

fluorescent magnetic with no audible noise<br />

Insures approval in residential applications<br />

Safely removes power to the lamp(s)<br />

SPECIALTY<br />

RESIDENTIAL<br />

6-2<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


UV DISINFECTION BALLASTS<br />

<strong>Electronic</strong> <strong>Ballasts</strong> for High Output (HO) Germicidal<br />

Ultraviolet (UV) Lamps<br />

In support of the growing popularity of High Output (HO) germicidal UV-C lamps--<br />

which have been proven effective at improving indoor air quality in low temperature<br />

environments such as HVAC systems--<strong>Advance</strong>'s PureVOLT electronic UV ballast is<br />

specially designed to operate a variety of 800mA HO UV lamps.<br />

PureVOLT is ideal in such applications as hospitals, food processing facilities,<br />

schools, office buildings, recreational facilities, and residences.<br />

Features<br />

Microprocessor-controlled design<br />

IntelliVolt® multiple-voltage technology<br />

enables operation at any input voltage from<br />

120 to 277 volts, 50/60Hz<br />

Benefits<br />

Enables one UV ballast to operate multiple lamps<br />

Enhances accuracy of ordering and reduces SKU<br />

requirements<br />

End-of-Lamp-Life Protection<br />

Safely removes power to the lamp(s)<br />

Auto-restart<br />

Programmed-start technology<br />

Eliminates the need to reset power mains after lamp<br />

replacement<br />

Provides extended lamp life in frequent switching<br />

applications<br />

SPECIALTY<br />

UV DISINFECTION<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 6-3


T4, T5, T8 & T12<br />

RESIDENTIAL LIGHTING<br />

For 7 - 42W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

UL Listed Lamp Types<br />

Page No.<br />

CFL Lamps<br />

1 or 2 120<br />

1 or 2 120<br />

1 or 2 120<br />

1 or 2 120<br />

1 or 2 120<br />

QS<br />

QS<br />

QS<br />

PS<br />

AmbiStar<br />

AmbiStar<br />

AmbiStar<br />

AmbiStar<br />

1 120 IS AmbiStar<br />

1 120<br />

1 or 2 120<br />

Linear T8 Lamps<br />

IS<br />

IS<br />

AmbiStar<br />

AmbiStar<br />

1 or 2 120 iS AmbiStar<br />

3 or 4 120 IS AmbiStar<br />

Linear T12 Lamps<br />

PS<br />

CFL & Linear T5 Lamps<br />

AmbiStar<br />

RCF-2S13-H1-LD-QS<br />

RCF-2S13-M1-BS-QS<br />

RCF-2S13-M1-LS-QS<br />

RCF-2S18-H1-LD-QS<br />

RCF-2S18-M1-BS-QS<br />

RCF-2S18-M1-LS-QS<br />

RCF-2S26-H1-LD-QS<br />

RCF-2S26-M1-BS-QS<br />

RCF-2S26-M1-LS-QS<br />

REB-2S18-M1-BS-DIM<br />

REB-2S18-M1-LS-DIM<br />

REB-2S26-M1-BS-DIM<br />

REB-2S26-M1-LS-DIM<br />

RMB-1P26-S2<br />

RMB-1P13-L2<br />

RMB-1P13-S1<br />

RMB-1P13-S2-H<br />

RMB-2P13-L2<br />

RMB-2P13-S2<br />

RMB-2P13-S2-H<br />

REB-2P32-SC<br />

REB-4P32-SC<br />

(1) or (2) 13W CFL 1-27, 1-29<br />

(1) or (2) 18W CFL 1-27, 1-30<br />

(1) or (2) 26W CFL<br />

(1) 32W, 42W CFL<br />

1-28, 1-31, 1-32<br />

(1) or (2) 18W CFL 2-5<br />

(1) or (2) 26W CFL<br />

(1) 32W, 42W CFL<br />

(1) 26W CFL<br />

(1) 18W, 24W Long Twin Tube or (1) 22W Circline<br />

(1) 7W, 9W, 13W CFL<br />

(1) F8T5, F13T5, F14T5 Linear<br />

(1) 18W or (2) 7W, 9W, 13W CFL<br />

(1) F8T5 & (1) F13T5 or (2) F8T5, F13T5, F14T5<br />

Linear<br />

(1) or (2) F17T8, F25T8, F32T8 Linear<br />

(3) or (4) F17T8, F25T8, F32T8 Linear<br />

2-5<br />

1-28, 1-31, 1-34<br />

1-42, 1-67<br />

1-26, 1-27, 1-29,<br />

1-40, 1-41<br />

1-26, 1-27, 1-29,<br />

1-30, 1-40, 1-41<br />

1-44, 1-45, 1-48,<br />

1-49, 1-58, 1-59<br />

1-46, 1-47, 1-50,<br />

1-51, 1-60, 1-61<br />

1 120 RS Standard RELB-2S40-SC<br />

(2) F34T12, F40T12 Linear<br />

1-67<br />

SPECIALTY<br />

RESIDENTIAL<br />

Above ballasts comply with the requirements of the Federal Communications Commission (FCC) rules and requlations Title 47 CFR Part 18,<br />

Consumer (Class B) for EMI/RFI (conducted and radiated).<br />

Above ballasts meet the ballast-controlled performance requirements in the ENERGY STAR Program Requirements for Residential Lite Fixtures<br />

The most current list of ballasts can be found at www.advance transformer.com/resources/literature in the file "ENERGY STAR Ballast Matrix"<br />

6-4<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


UV DISINFECTION<br />

For 15 - 145W Lamps<br />

T5, T8 & T5/HO<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Lamp<br />

Current<br />

(mAmps)<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

PL-L18W/TUV (18W)<br />

1 120 - 277 PS PureVOLT IUV-2S18-H1-LD 30 290 10 0.26 - 0.11 0/-18 Size 1 160<br />

2 120 - 277 PS PureVOLT IUV-2S18-H1-LD 55 280 10 0.47 - 0.20 0/-18 Size 1 159<br />

PL-L36W/TUV (36W)<br />

1 120 - 277 PS PureVOLT IUV-2S36-M2-LD 51 330 10 0.44 - 0.19 0/-18 Size 2 160<br />

2 120 - 277 PS PureVOLT IUV-2S36-M2-LD 90 285 10 0.78 - 0.33 0/-18 Size 2 159<br />

PL-L35WHO/TUV (35W)<br />

1 120 - 277 PS PureVOLT<br />

IUV-2S60-M4-BS<br />

IUV-2S60-M4-LD<br />

40 850 10 0.35 - 0.15 0/-18 Size 4 160<br />

2 120 - 277 PS PureVOLT<br />

IUV-2S60-M4-BS<br />

IUV-2S60-M4-LD<br />

78 850 10 0.68 - 0.29 0/-18 Size 4 159<br />

PL-L60WHO/TUV (60W)<br />

1 120 - 277 PS PureVOLT<br />

IUV-2S60-M4-BS<br />

IUV-2S60-M4-LD<br />

70 850 10 0.60 - 0.26 0/-18 Size 4 160<br />

2 120 - 277 PS PureVOLT<br />

IUV-2S60-M4-BS<br />

IUV-2S60-M4-LD<br />

138 850 10 1.20 - 0.52 0/-18 Size 4 159<br />

PL-L95WHO/TUV (95W)<br />

1 120 - 277 PS PureVOLT<br />

IUV-2S60-M4-BS<br />

IUV-2S60-M4-LD<br />

100 800 10 0.87 - 0.37 0/-18 Size 4 160<br />

G15T8 (15W)<br />

1 120 IS Standard REL-2P30G<br />

20 290 30 0.17 0/-18 A *64<br />

2 120 IS Standard REL-2P30G<br />

26 220 20 0.22 0/-18 A 64<br />

G30T8 (30W)<br />

1 120 IS Standard REL-2P30G<br />

30 260 20 0.25 0/-18 A *64<br />

2 120 IS Standard REL-2P30G<br />

45 470 20 0.38 0/-18 A 64<br />

G64T5 (75W)<br />

2 120 IS Standard REL-2P64-IS<br />

179 500 20 1.65 0/-18 C 64<br />

SPECIALTY<br />

UV DISINFECTION<br />

TUV 36T5/HO (75W)<br />

1 120 - 277 PS PureVOLT<br />

IUV-2S60-M4-BS<br />

IUV-2S60-M4-LD<br />

80 800 10 0.69 - 0.30 0/-18 Size 4 160<br />

2 120 - 277 PS PureVOLT<br />

IUV-2S60-M4-BS<br />

IUV-2S60-M4-LD<br />

155 800 10 1.30 - 0.56 0/-18 Size 4 159<br />

TUV 64T5/HO (145W)<br />

1 120 - 277 PS PureVOLT<br />

IUV-2S60-M4-BS<br />

IUV-2S60-M4-LD<br />

155 800 10 1.30 - 0.56 0/-18 Size 4 160<br />

See page 6-7 for Ballast Dimensions<br />

See page 6-8 for Wiring Diagrams<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

6-5


T8 & T12/HO<br />

REFRIGERATION, TANNING AND DISPLAY<br />

For 13 - 168W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

REFRIGERATION<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F58T8 (58W)<br />

1 120 - 277 PS Centium<br />

ICN-2S54<br />

ICN-2S54-90C<br />

58 1.00 10 0.49 - 0.22 -20/-18 D 73<br />

2 120 - 277 PS Centium<br />

ICN-2S54<br />

ICN-2S54-90C<br />

116 1.00 10 0.97 - 0.42 -20/-18 D 74<br />

3 120 - 277 PS Centium<br />

ICN-4S54-90C-2LS<br />

D<br />

171 1.00 10 1.43 - 0.62 -20/-18<br />

ICN-4S54-90C-2LS-G<br />

G<br />

*75<br />

4 120 - 277 PS Centium<br />

ICN-4S54-90C-2LS<br />

D<br />

225 1.00 10 1.88 - 0.81 -20/-18<br />

ICN-4S54-90C-2LS-G<br />

G<br />

75<br />

F70T8 (70W)<br />

1 120 - 277 PS Centium ICN-1S80<br />

73 0.77 10 0.62 - 0.26 -20/-18 D 73<br />

TANNING<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F73T12/HO (1000mA) 100W<br />

2 120 RS Magnetic RS-2S100-TP 1 226 1.12 15 2.00 -20/-18 R-9 21<br />

F72T12/VHO (1500mA) 168W<br />

2 120 RS Magnetic RS-2S200-TP<br />

270 0.89 20 2.51 -20/-18 R-11 21<br />

SPECIALTY<br />

REFRIGERATION,<br />

TANNING, DISPALY<br />

1 RS-2S100-TP is only UL approve<br />

DISPLAY<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

F15T8/PLUS, F15T8/XL, FO13T8/XP<br />

Catalog Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

2 120 IS Standard REL-2P32-SC<br />

28 0.95 30 0.24 0/-18 B 64<br />

Dim.<br />

Wiring<br />

Dia.<br />

3 120 IS Standard REL-3P32-SC<br />

40 0.95 20 0.34 0/-18 B 65<br />

4 120 IS Standard REL-4P32-SC<br />

50 0.95 20 0.43 0/-18 B 66<br />

See page 6-7 for Ballast Dimensions<br />

See page 6-8 for Wiring Diagrams<br />

6-6<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


BALLAST DIMENSIONS<br />

Size 12.40"<br />

Size 2<br />

3.00"<br />

Size 4<br />

0.98"<br />

1.29"<br />

1.29"<br />

7.50"<br />

7.00"<br />

7.00"<br />

7.50"<br />

2.00"<br />

1.29"<br />

4.20"<br />

4.60"<br />

4.20"<br />

4.60"<br />

-LD<br />

-LD<br />

3.00"<br />

3.00"<br />

1.18"<br />

8.90"<br />

9.5"<br />

Fig. B<br />

Fig. A<br />

1.7"<br />

1 25 /32”<br />

Fig. D<br />

2 7 /8”<br />

11 3 /4”<br />

11 9 /64”<br />

Slimline<br />

Fig. C<br />

and HO<br />

H<br />

SPECIALTY<br />

1.18"<br />

16.34"<br />

1.70"<br />

16.70"<br />

Fig. G<br />

W<br />

M<br />

L<br />

Case “R”<br />

DIMENSIONS<br />

Designation<br />

Length (L)<br />

(inches)<br />

Width (W)<br />

(inches)<br />

Height (H)<br />

(inches)<br />

Mounting (M)<br />

(inches)<br />

R-9 11³₄ 3³₁₆ 2⁵₈ 11⁹₆₄<br />

R-11 14³₈ 3³₁₆ 2⁵₈ 13³₄<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 6-7


WIRING DIAGRAMS<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

LAMP<br />

LINE<br />

LAMP<br />

Diag. 64<br />

* For Single Lamp Operation, insulate unused<br />

Diag. 159<br />

blue lead for 600 volts<br />

Diag. 160<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

WHITE<br />

BLACK<br />

RED<br />

BALLAST<br />

BLUE<br />

BLUE<br />

BLUE<br />

LAMP<br />

LAMP<br />

LINE<br />

LINE<br />

LAMP<br />

LAMP<br />

LAMP<br />

Diag. 64<br />

Diag. 65<br />

Diag. 21<br />

* For Single Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

* For Two Lamp Operation, insulate unused<br />

blue lead for 600 volts<br />

WHITE<br />

BLACK<br />

YELLOW<br />

YELLOW<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

LAMP<br />

LAMP<br />

LINE<br />

LAMP<br />

LAMP<br />

Diag. 66<br />

For 1 lamp operation, do not use yellow leads<br />

* For Three Lamp Operation,<br />

insulate unusedblue lead for 600 volts<br />

Diag. 73<br />

SPECIALTY<br />

Diag. 75<br />

Diag. 74<br />

* For 3-lamp operation connect lamps<br />

between RED and BLUE, BROWN and<br />

BLUE/WHT, YELLOW and BLUE/WHT<br />

6-8<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INTERNATIONAL HIGH FREQUENCY<br />

ELECTRONIC FLUORESCENT BALLASTS<br />

The following Philips labeled electronic ballasts are available for PLL, T5, T5/HO<br />

and TLD lamps at 220-240 volts (50 or 60 Hertz).<br />

HF-PERFORMER BALLASTS<br />

The HF-Performer electronic ballast is a premium performance<br />

ballast designed specifically for IEC-Specification linear and long<br />

twin tube fluorescent lamps.<br />

Features Include:<br />

• Programmed Rapid Start design optimizes lamp life under all<br />

starting scenarios<br />

• Integrated Circuit-based control technology monitors lamp and<br />

ballast conditions to ensure optimum lighting system performance<br />

• Reduced inrush current; Poke-in WAGO lead connectors<br />

• Designed to meet major European national safety and performance<br />

standards<br />

HF-Performer Ballast Specifications:<br />

1. Ballast shall operate from a nominal line voltage of 220 thru 240<br />

volts, 50/60 Hz. Ballast shall maintain constant wattage output<br />

throughout the operating voltage range<br />

2. Ballast shall be Programmed Start<br />

3. Ballast Power Factor shall be >96%<br />

4. Ballast Total Harmonic Distortion (THD) shall be 15%<br />

5. Ballast shall start the lamp at a min. temperature of 0°F (-15°C)<br />

6. Ballast shall be sound rated A<br />

7. Ballast shall contain no PCB’s<br />

8. Ballast shall carry a 2 year warranty when its case temperature<br />

does not exceed 60°C<br />

9. Complies with safety regulation EN6137-2-3<br />

10. Complies with performance regulation EN60929<br />

11. Complies with EN 55015 for EMI<br />

12. Complies with EU directive 2002/95/EC (RoHS)<br />

13. Approvals: CE<br />

HF-BASIC BALLASTS<br />

The HF-Basic electronic ballast is a standard performance ballast<br />

designed specifically for IEC-Specification TLD fluorescent lamps.<br />

Features Include:<br />

• Instant start design provides greatest operating efficiencies<br />

• Designed to meet major European national safety and performance<br />

standards<br />

• Poke-in WAGO lead connectors<br />

HF-Basic Ballast Specifications:<br />

1. Ballast shall operate from a nominal line voltage of 220 thru 240<br />

volts, 50/60 Hz. Ballast shall maintain constant wattage output<br />

throughout the operating voltage range<br />

2. Ballast shall be Instant Start<br />

3. Ballast Power Factor shall be >96%<br />

4. Ballast Total Harmonic Distortion THD shall be 20%<br />

5. Ballast shall start the lamp at a min. temperature of 0°F (-15°C)<br />

6. Ballast shall be sound rated A<br />

7. Ballast shall contain no PCB’s<br />

8. Ballast shall carry a 2 year warranty when its case temperature<br />

does not exceed 60°C<br />

9. Complies with EN6137-2-3 safety regulation<br />

10. Complies with EN60929 performance regulation<br />

11. Complies with EN 55015 for EMI<br />

12. Complies with EU directive 2002/95/EC (RoHS)<br />

13. Approvals: CE<br />

INTELLIVOLT BALLASTS<br />

<strong>Advance</strong> offers many ballast featuring IntelliVolt input capability. These ballasts will operate on input voltages from 120 through 277 volts<br />

(50 or 60 Hertz). They are designed for ANSI-Specification linear and compact fluorescent lamps, but are only UL and CSA approved.<br />

The fixture or equipment manufacturer must obtain other local approvals, like CE, in order to use these ballasts in locations other than<br />

North America. See <strong>Section</strong> 1 of this <strong>Atlas</strong>, for available ballasts.<br />

INTERNATIONAL<br />

ELECTRONIC<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 6-9


PLL<br />

INTERNATIONAL ELECTRONIC<br />

For 36 - 55W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Hz<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog<br />

Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

PLL 36W<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 136 PLL 37 0.95 10 0.16 0/-18 A1 3<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 236 PLL 70 0.95 10 0.30 0/-18 A2 4<br />

PLL 40W<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 140 PLL 44 0.95 10 0.19 0/-18 A1 3<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 240 PLL 84 0.95 10 0.36 0/-18 A2 4<br />

PLL 55W<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 155 PLL 58 0.95 10 0.25 0/-18 A1 3<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 255 PLL 113 0.95 10 0.49 0/-18 A2 4<br />

DIMENSIONS<br />

Dimensions A1 A2 B1 C1<br />

Fig. A1 11.02” 10.43” 1.18” 1.10”<br />

Fig. A2 11.02” 10.43” 1.18” 1.10”<br />

D1<br />

0.165”<br />

0.165”<br />

INTERNATIONAL<br />

ELECTRONIC<br />

Diag. 3<br />

Fig. A1 & Fig.A2<br />

Diag. 4<br />

6-10<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INTERNATIONAL ELECTRONIC<br />

For 14 - 54W Lamps<br />

T5 and T5HO<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Hz<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog<br />

Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F14T5 (14W)<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 14-35 TL5 HE 18 0.95 15 0.08 0/-18 A1 1<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 14-35 TL5 HE 30 0.95 15 0.14 0/-18 A2 2<br />

F21T5 (21W)<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 14-35 TL5 HE 25 0.95 15 0.11 0/-18 A1 1<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 14-35 TL5 HE 46 0.95 15 0.20 0/-18 A2 2<br />

F28T5 (28W)<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 14-35 TL5 HE 33 0.95 15 0.15 0/-18 A1 1<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 14-35 TL5 HE 61 0.95 15 0.27 0/-18 A2 2<br />

F35T5 (35W)<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 14-35 TL5 HE 40 0.95 15 0.18 0/-18 A1 1<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 14-35 TL5 HE 76 0.95 15 0.33 0/-18 A2 2<br />

F24T5/HO (21W)<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 24-39 TL5 HO 28 0.95 15 0.12 0/-18 A3 1<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 24-39 TL5 HO 49 0.95 15 0.22 0/-18 A4 2<br />

F39T5/HO (39W)<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 24-39 TL5 HO 45 0.95 15 0.20 0/-18 A3 1<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 24-39 TL5 HO 86 0.95 15 0.39 0/-18 A4 2<br />

F54T5/HO (54W)<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 54 TL5 HO 61 0.95 15 0.27 0/-18 A3 1<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 54 TL5 HO 120 0.95 15 0.52 0/-18 A4 2<br />

See page 6-12 for Ballast Dimensions<br />

INTERNATIONAL<br />

ELECTRONIC<br />

Diag. 1<br />

Diag. 2<br />

Refer to pages 8-32 to 8-41 for lead lengths and shipping data<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

6-11


TLD<br />

INTERNATIONAL ELECTRONIC<br />

For 18 - 36W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Hz<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog<br />

Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

TLD 18W<br />

1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 118 TLD 19 0.95 15 0.09 0/-18 A1 1<br />

2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 218 TLD 37 0.95 15 0.18 0/-18 A2 2<br />

TLD 36W<br />

1 220 - 240 50 - 60<br />

IS HF-BASIC HF-B 136 TLD 37 0.95 20 0.16<br />

PS HF-PERFORMER HF-P 136 TLD 37 0.95 15 0.16<br />

0/-18<br />

2 220 - 240 50 - 60<br />

IS HF-BASIC HF-B 236 TLD 70 0.95 20 0.32<br />

PS HF-PERFORMER HF-P 236 TLD 70 0.95 15 0.31<br />

0/-18<br />

TLD 58W<br />

1 220 - 240 50 - 60<br />

IS HF-BASIC HF-B 158 TLD 57 0.95 20 0.24<br />

PS HF-PERFORMER HF-P 158 TLD 56 0.95 15 0.24<br />

0/-18<br />

2 220 - 240 50 - 60<br />

IS HF-BASIC HF-B 258 TLD 110 0.95 20 0.48<br />

PS HF-PERFORMER HF-P 258 TLD 107 0.95 15 0.48<br />

0/-18<br />

DIMENSIONS<br />

A1<br />

A2<br />

A1<br />

A2<br />

1<br />

2<br />

1<br />

2<br />

Dimensions A1 A2 B1 C1<br />

Fig. A1 11.02” 10.43” 1.18” 1.10”<br />

Fig. A2 11.02” 10.43” 1.18” 1.10”<br />

Fig. A3 14.17 13.78” 1.18” 0.83”<br />

Fig. A4 14.17 13.78” 1.18” 0.83”<br />

D1<br />

0.165”<br />

0.165”<br />

0.165”<br />

0.165”<br />

Diag. 1<br />

Diag. 2<br />

INTERNATIONAL<br />

ELECTRONIC<br />

Fig. A1 & Fig.A2<br />

Fig. A3 & Fig.A4<br />

6-12<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INTERNATIONAL ELECTROMAGNETIC FLUORESCENT BALLASTS<br />

ADVANCE offers an extended range of electromagnetic fluorescent ballasts to<br />

operate T8, T10, T12 and compact fluorescent lamps. These ballasts are suitable for<br />

International markets and range in voltage from 120 through 277V, 50 & 60 Hz.<br />

Supply Voltage and Frequency<br />

Each ballast is designed to operate at the nominal voltage shown on<br />

the ADVANCE label. Abnormal deviation from these values will result<br />

in damage to either the ballast or lamp or both. It is therefore necessary<br />

that the voltage applied to ballasts be maintained within the<br />

respective limits shown in the adjoining table.<br />

A ballast subjected to higher than nominal voltages will operate at<br />

increased temperatures. This will result in reduced ballast life. Low<br />

voltage can cause premature lamp failures as well as unreliable lamp<br />

starting.<br />

All ballasts are designed for single frequency operation. Therefore,<br />

best results will be obtained when that ballast is used on the frequency<br />

shown on the ballast label. Frequency limitations are as follows:<br />

Nominal Frequency Limits<br />

60HZ 57.5 to 62.5<br />

50HZ 47.5 to 52.5<br />

Prefix<br />

Code<br />

Letters<br />

Normal<br />

Voltage<br />

Applied Voltage<br />

Limits<br />

Color Label<br />

Identification<br />

H 120 112-127 YELLOW<br />

R 120 112-127 YELLOW<br />

L 120 112-127 YELLOW<br />

S 120 112-127 YELLOW<br />

X 220 210-230 GREEN<br />

M 220/250 210-230 / 235-260 —<br />

Y 240 225-250 ORANGE<br />

V 277 255-290 RED<br />

G 347 322-365 GRAY<br />

CERTIFICATIONS<br />

NOM<br />

All <strong>Advance</strong> ballasts unless otherwise indicated<br />

bear the seal of Underwriters’ Laboratories, Inc. in<br />

accordance with UL935 Standard for Fluorescent<br />

<strong>Ballasts</strong>. File No. E14927<br />

<strong>Advance</strong> ballasts which meet the Canadian<br />

Standards Association requirements for Fluorescent<br />

<strong>Ballasts</strong> per CAN/CSA-22.2 No. 74-92 bear the CSA<br />

seal. File No. LR7310<br />

<strong>Advance</strong> fluorescent ballasts are designed<br />

and manufactured in accordance with the<br />

American National Standards Institute standard<br />

for fluorescent ballasts, ANSI C82.1.<br />

Norma Obligatorio Mexicana<br />

(contact your local salesperson for availability)<br />

Class P <strong>Ballasts</strong> — <strong>Section</strong> 410-73(e) of the National <strong>Electric</strong>al<br />

Code (NEC) requires that all indoor fluorescent fixtures shall incorporate<br />

ballast protection. Those fixtures employing a simple reactive<br />

type ballast are excepted.<br />

The protector is located within the ballast case to prevent physical<br />

damage and tampering.<br />

<strong>Advance</strong> electromagnetic ballasts ordered with ADVAN-guard ®<br />

Class P ballast protection (TP suffix) are equipped with a thermally<br />

actuated automatic reclosing protective device. This revolutionary<br />

development was originally designed and introduced by <strong>Advance</strong>,<br />

and today this Class P device is a requirement of the National<br />

<strong>Electric</strong>al Code in all indoor lighting installations.<br />

Starting<br />

The metal of a fluorescent fixture is a starting aid when properly<br />

grounded. T12 Fluorescent lamps rated at 40 watts or less used for<br />

rapid or trigger start operation must be mounted within 1/2” of a<br />

grounded metal surface. T8 Lamps must be mounted within 3/4”<br />

of a grounded metal surface. All other lamps must be mounted<br />

within 1” of a grounded metal surface.<br />

An important additional factor for proper lamps starting is polarity.<br />

The white ballast lead must be connected to the ground of the power<br />

supply (neutral) and the black lead to the hot line wire. A reversal of<br />

polarity may result in lamp damage or improper lamp starting.<br />

INTERNATIONAL<br />

ELECTROMAGNETIC<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 6-13


T12<br />

INTERNATIONAL ELECTROMAGNETIC<br />

For 30 - 40W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Hz<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog<br />

Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F30T12 (430mA) 30W<br />

1 220 - 250 50 RS Magnetic MTM-140-TP 50 0.88 20 0.24 50/10 R5 18<br />

F34T12 (460mA) 34W<br />

1 120 60 RS Magnetic HM-140-TP 46 0.89 10 0.39 60/16 T2 20<br />

R-2S40-TP 72 0.88 15 0.63<br />

120 60<br />

RQM-2S40-TP 82 0.88 25 0.74<br />

2 RS Magnetic<br />

60/16<br />

220 or 250 50<br />

MTM-2S40-TP 75 0.83 30 0.39<br />

T2<br />

R5<br />

21<br />

76<br />

277<br />

60<br />

VQM-2S40-TP<br />

78 0.91 15<br />

0.29<br />

T2<br />

21<br />

F40T12 (430mA) 40W<br />

120 60 HM-140-TP 53 0.95 10 0.45<br />

T2<br />

1 RS Magnetic 50/10 20<br />

220 or 250 50 MTM-140-TP 51 0.88 20 0.24<br />

R5<br />

120<br />

60<br />

R-2S40-TP<br />

RQM-2S40-TP<br />

86 0.95 15<br />

96 0.95 25<br />

0.73<br />

0.84<br />

T2<br />

21<br />

2 RS Magnetic TM-2S40-TP • 90 0.91 20 0.75 50/10<br />

50<br />

220 or 250<br />

MTM-2S40-TP 88 0.90 25 0.42<br />

R5<br />

76<br />

277 60<br />

VQM-2S40-TP<br />

91 0.96 20<br />

0.33<br />

T2<br />

21<br />

• Sound Rated B<br />

INTERNATIONAL<br />

ELECTROMAGNETIC<br />

BLUE<br />

BLUE<br />

BLACK<br />

LINE WHITE<br />

YEL-BLUE<br />

Insulate unused power<br />

lead for 300 volts<br />

LAMP<br />

BALLAST<br />

220 V<br />

250 V<br />

Diag. 18<br />

RED<br />

RED<br />

INE<br />

BLUE<br />

BLUE<br />

WHITE<br />

BLK/WHT<br />

LAMP<br />

BALLAST<br />

Diag. Diag. 20 20<br />

RED<br />

RED<br />

Diag. 21<br />

LAMP<br />

LAMP<br />

YELLOW<br />

YELLOW<br />

WHITE BALLAST<br />

LINE<br />

BLACK 220 V<br />

YEL-BLUE 250 V<br />

Insulate unused power lead<br />

for 300 volts<br />

Diag. 76<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

DIMENSIONS<br />

Diag. 76<br />

Designation<br />

Length (L)<br />

(inches)<br />

Width (W)<br />

(inches)<br />

Height (H)<br />

(inches)<br />

Mounting (M)<br />

(inches)<br />

H<br />

R-5 9¹₂ 2³₈ 1¹¹₁₆ 8²⁹₃₂<br />

T-2 9¹₂ 2³₈ 1¹₂ 8²⁹₃₂<br />

W<br />

M<br />

L<br />

Case “R”<br />

6-14<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INTERNATIONAL ELECTROMAGNETIC<br />

For 60 - 110W Lamps<br />

T12/HO<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Hz<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog<br />

Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F48T12/HO (800mA) 60W<br />

2 220 or 250 50 RS Magnetic MT-2S110-TP 140 0.87 25 0.70 0/-18 R9 21<br />

F72T12/HO (800mA) 85W<br />

2 220 or 250 50 RS Magnetic MT-2S110-TP 224 0.93 20 1.03 0/-18 R9 21<br />

F96T12/HO (800mA) 110W<br />

2 220 or 250 50 RS Magnetic MT-2S110-TP 280 0.92 15 1.26 0/-18 R9 21<br />

DIMENSIONS<br />

Designation<br />

Length (L)<br />

(inches)<br />

Width (W)<br />

(inches)<br />

Height (H)<br />

(inches)<br />

Mounting (M)<br />

(inches)<br />

R-9 11³₄ 3³₁₆ 2⁵₈ 11⁹₆₄<br />

H<br />

W<br />

M<br />

L<br />

Case “R”<br />

Diag. 21<br />

INTERNATIONAL<br />

ELECTROMAGNETIC<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

6-15


T12 Slimline<br />

INTERNATIONAL ELECTROMAGNETIC<br />

For 40 - 75W Lamps<br />

HIGH POWER FACTOR<br />

SOUND RATED C<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Hz<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog<br />

Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F48T12 (425mA) 40W<br />

ADM-2E40-S<br />

2 120 60 IS Magnetic<br />

63 0.84 30 0.75 50/10 R-6<br />

ADM-2E40-S-TP<br />

F60T12 (425mA) 50W<br />

2<br />

120<br />

60<br />

277<br />

F64T12 (425mA) 52W<br />

2<br />

120<br />

277<br />

60<br />

F72T12 (425mA) 57W<br />

IS<br />

IS<br />

Magnetic<br />

Magnetic<br />

R-2E75-S-TP<br />

SM-2E75-S-TP<br />

VSM-2E75-S-TP<br />

R-2E75-S-TP<br />

SM-2E75-S-TP<br />

VSM-2E75-S-TP<br />

111 0.94 30<br />

126<br />

112<br />

0.98<br />

0.94<br />

30<br />

25<br />

117 0.95 30<br />

126<br />

116<br />

0.99<br />

0.95<br />

25<br />

25<br />

1.03<br />

1.10<br />

0.45<br />

1.07<br />

1.10<br />

0.45<br />

0/-18<br />

50/10<br />

0/-18<br />

50/10<br />

R-8<br />

R-8<br />

12<br />

12<br />

36<br />

12<br />

36<br />

1 120 60 IS Magnetic A-175-S 60 0.67 50 0.60 50/10 R-5 10<br />

ADM-2E75-S<br />

85 0.59 45 0.81 50/10 R-6<br />

ADM-2E75-S-TP<br />

120<br />

2 60 IS Magnetic R-2E75-S-TP 132 0.94 30 1.18 0/-18<br />

SM-2E75-S-TP 130 0.98 25 1.20<br />

R-8<br />

50/10<br />

277<br />

VSM-2E75-S-TP 129 0.93 25 0.50<br />

F96T12 (425mA) 75W<br />

12<br />

36<br />

1 120 60 IS Magnetic A-175-S 69 0.67 25 0.62 50/10 R-5 10<br />

2<br />

120<br />

277<br />

60<br />

IS<br />

Magnetic<br />

ADM-2E75-S<br />

ADM-2E75-S-TP<br />

111<br />

R-2E75-S-TP 158<br />

SM-2E75-S-TP 170<br />

VSM-2E75-S-TP 159<br />

0.59 40 1.05<br />

R-6<br />

12<br />

0.94 30 1.35 50/10<br />

0.97 25 1.40<br />

R-8<br />

0.92 30 0.60 36<br />

INTERNATIONAL<br />

ELECTROMAGNETIC<br />

DIMENSIONS<br />

Designation<br />

Length (L)<br />

(inches)<br />

Width (W)<br />

(inches)<br />

Height (H)<br />

(inches)<br />

Mounting (M)<br />

(inches)<br />

R-5 9¹₂ 2³₈ 1¹¹₁₆ 8²⁹₃₂<br />

R-6 9¹₂ 3⁷₆₄ 1²⁵₃₂ 8²⁹₃₂<br />

W<br />

R-8 11³₄ 3⁷₆₄ 1²⁵₃₂ 11⁹₆₄ Case “R”<br />

H<br />

M<br />

L<br />

CUTOUT LAMPHOLDER<br />

LINE<br />

WHITE<br />

BLK/WHT<br />

CUTOUT LAMPHOLDER<br />

LAMP<br />

BALLAST<br />

BLUE<br />

BLACK<br />

WHITE<br />

LAMP<br />

BALLAST<br />

BLUE<br />

RED<br />

LINE<br />

BROWN,<br />

WHITE or<br />

YEL-BLUE<br />

BLACK<br />

YELLOW<br />

YELLOW<br />

CUTOUT LAMPHOLDER<br />

LAMP<br />

BALLAST<br />

RED<br />

BLUE<br />

LINE<br />

LAMP<br />

LAMP<br />

Diag. 10<br />

CUTOUT LAMPHOLDER<br />

Diag. 12<br />

CUTOUT LAMPHOLDER<br />

Diag. 36<br />

6-16<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INTERNATIONAL ELECTROMAGNETIC<br />

For 13 - 40W Lamps<br />

T8,T12,T9<br />

HIGH POWER FACTOR<br />

SOUND RATED A<br />

No. of<br />

Lamps<br />

Input<br />

Volts<br />

Hz<br />

Lamp<br />

Starting<br />

Method<br />

Ballast<br />

Family<br />

Catalog<br />

Number<br />

Input<br />

Power<br />

ANSI<br />

(Watts)<br />

Ballast<br />

Factor<br />

Max.<br />

THD<br />

%<br />

Line<br />

Current<br />

(Amps)<br />

Min.<br />

Starting<br />

Temp.<br />

(°F/°C)<br />

Dim.<br />

Wiring<br />

Dia.<br />

F15T8 (15W)<br />

1 220 60 PH Magnetic XHM-1P20-TP 26 0.89 20 0.12 0/-18 T-2 20<br />

2 220 60 PH Magnetic XM-2SP20-TP 51 0.82 20 0.28 0/-18 T-2 21<br />

F14T12 (14W)<br />

1 220 60 PH Magnetic XHM-1P20-TP 22 0.78 15 0.11 0/-18 T-2 20<br />

2 220 60 PH Magnetic XM-2SP20-TP 45 0.85 10 0.24 0/-18 T-2 21<br />

F15T12 (15W)<br />

1 220 60 PH Magnetic XHM-1P20-TP 23 0.86 15 0.11 0/-18 T-2 20<br />

2 220 60 PH Magnetic XM-2SP20-TP 44 0.79 15 0.25 0/-18 T-2 21<br />

F20T12 (20W)<br />

1 220 60 PH Magnetic XHM-1P20-TP 25 0.72 20 0.12 0/-18 T-2 20<br />

2 220 60 PH Magnetic XM-2SP20-TP 53 0.86 20 0.27 0/-18 T-2 21<br />

F16T9 (40W Circline)<br />

1 220 or 250 50 RS Magnetic MTM-140-TP 51 0.88 20 0.24 50/10 R-5 18<br />

CFT13W/GX23 (PL-S13W, F13BX, CF13DS) or CFQ13W/GX23 (PL-C13W/USA, F13BX23T4, CF13DD)<br />

1 220 50 PH Magnetic XTH-1B13-TP-W 21 0.98 15 0.10 0/-18 R-2 47<br />

LAMP<br />

LAMP<br />

BLK/WHT BLACK<br />

BLUE<br />

BLUE<br />

BLACK<br />

LINE WHITE<br />

YEL-BLUE<br />

Insulate unused power<br />

lead for 300 volts<br />

BALLAST<br />

220 V<br />

250 V<br />

Diag. 18<br />

RED<br />

RED<br />

LINE<br />

BLUE<br />

BLUE<br />

WHITE<br />

BLK/WHT<br />

BALLAST<br />

Diag. Diag. 20 20<br />

RED<br />

RED<br />

Diag. 21<br />

BLUE<br />

BALLAST<br />

WHITE<br />

Diag. 47<br />

LINE<br />

WHITE<br />

INTERNATIONAL<br />

ELECTROMAGNETIC<br />

DIMENSIONS<br />

Designation<br />

Length (L)<br />

(inches)<br />

Width (W)<br />

(inches)<br />

Height (H)<br />

(inches)<br />

Mounting (M)<br />

(inches)<br />

R-2 4³₄ 2⁷₃₂ 1⁵₈ 4³₈+<br />

R-5 9¹₂ 2³₈ 1¹¹₁₆ 8²⁹₃₂<br />

T-2 9¹₂ 2³₈ 1¹₂ 8²⁹₃₂<br />

H<br />

W<br />

Case “R”<br />

M<br />

L<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

6-17


SPECIALTY ELECTROMAGNETIC HID BALLASTS<br />

Specialty Customer Support / Technical Service phone: (+) 1 847 390-5000<br />

Specialty Customer Support fax: (+) 1 847 390-5366<br />

Specialty Technical Support fax: (+) 1 847 768-7768<br />

<strong>Advance</strong> offers an extensive range of High Intensity Discharge ballasts to run ANSI<br />

specification (U.S. style) lamps. These ballasts are suitable for Specialty markets<br />

and range in voltage from 100 through 415V, 50 & 60 Hz.<br />

ADVANCE ® HID Lamp <strong>Ballasts</strong> are available to operate the wide<br />

variety of mercury, metal halide, high pressure sodium and low pressure<br />

sodium lamps available in today’s marketplace.<br />

Like fluorescent, HID lamps are electric discharge lamps. Light is<br />

produced by an arc discharge between two electrodes located at<br />

opposite ends of an arc tube within the lamp’s outer glass envelope.<br />

The ballast is the lamp’s power supply; its purpose is to provide<br />

proper starting and operating voltage and current to initiate and sustain<br />

this arc.<br />

Core & Coil<br />

The basic ballast is the open core & coil which is most often used<br />

as a component within a lighting fixture. The core & coil also forms<br />

the nucleus of the five other ballast configurations detailed in this<br />

section. It consists of either one, two or three copper coils on a core<br />

(or “stack”) of electrical-grade steel laminations. The coils are<br />

assembled to core sections which are then surface-welded together.<br />

At <strong>Advance</strong> Transformer Co. the assembled ballast is vacuum<br />

impregnated with a silica-filled polyester varnish to re-enforce the<br />

electrical insulation, preclude moisture, inhibit noise, and dissipate<br />

heat. Other HID ballast manufacturers apply varnish via a preheatand-dip<br />

process which only puts a thin coat of varnish on the outer<br />

surface of the ballast.<br />

Encapsulated Core & Coil<br />

Where quiet performance is required, the standard open core &<br />

coil ballasts are encapsulated (potted) in a cube-shaped steel can utilizing<br />

Class H (180°C) polyester compound. These ballasts carry a<br />

Class A noise rating up through 175 watts and Class B for 250 and<br />

400 watts. As with the open core & coil, the capacitor (and ignitor<br />

where included) are mounted separately within the fixture.<br />

Replacements<br />

For capacitors, see pages 4-48 to 4-49<br />

For ignitors, see pages 4-50 to 4-53<br />

Special Voltages<br />

For voltage and frequencies not shown in the charts of the following<br />

pages, please contact your <strong>Advance</strong> Sales Representative.<br />

CERTIFICATIONS<br />

Indicates ballast is listed by Underwriters Laboratories,<br />

Inc. in accordance with UL 1029 Standard for HID <strong>Ballasts</strong>.<br />

Each ballast is marked appropriately.<br />

NOM<br />

All HID <strong>Ballasts</strong> are designed and manufactured<br />

in accordance with the American National<br />

Standards Institute Standard for HID <strong>Ballasts</strong>, ANSI<br />

C82.4.<br />

Norma Obligatorio Mexicana.<br />

(contact your local salesperson for availability)<br />

SPECIALTY<br />

HID<br />

6-18<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

50 HZ Core & Coil <strong>Ballasts</strong><br />

(Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Mercury<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

U.L.<br />

Bench<br />

Top Rise<br />

Code<br />

1029<br />

(Pg 5-3)<br />

100 Watt Lamp, ANSI Code H38 or H44<br />

120/<br />

220/240<br />

71A25N1 CWA 125<br />

1.2/<br />

.7/.6<br />

240<br />

3/<br />

2/2<br />

1 1.3 2.6 12 280 7C120M33-R D 5.0<br />

125 Watt Lamp, ANSI Code H42<br />

220/240 71A29R0 CWA 150 .7/.7 255 2/2 A 1 1.7 3.0 14 280 7C140M33-R D 6.0 D/D<br />

175 Watt Lamp, ANSI Code H39<br />

120/<br />

See 175W Metal Halide CWA 71A55NO (page 6-16)<br />

220/240<br />

250 Watt Lamp, ANSI Code H37<br />

120/<br />

220/240<br />

400 Watt Lamp, ANSI Code H33<br />

120/<br />

220/240<br />

1000 Watt Lamp, ANSI Code H36<br />

120/<br />

220/240<br />

A<br />

See 250W Metal Halide CWA 71A57N0 (page 6-16)<br />

See 400W Metal Halide CWA 71A60N1 (page 6-16)<br />

See 1000W Metal Halide CWA 71A65N2 (page 6-16)<br />

B/<br />

B/B<br />

✝ Ordering information:<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-600 core & coil only (no capacitor)<br />

• For CWA circuits, figure is operating current.<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

CAP<br />

CAP<br />

LAMP<br />

LAMP<br />

COM<br />

COM<br />

Fig. A<br />

B<br />

MAX.<br />

A<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

B<br />

MAX.<br />

A<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

LINE V<br />

LAMP<br />

2 13 /16"<br />

4 1 /4"<br />

OPTIONAL)<br />

CAP<br />

LAMP<br />

2 7 /16"<br />

3 1 /2" 3 15 /16"<br />

Fig. 1<br />

(3" x 4" core)<br />

3 7 /8"<br />

4 3 /8" 4 3 /4"<br />

Fig. 2<br />

(4 1 /4" x 4 3 /4" core)<br />

COM<br />

Fig. G<br />

INTERNATIONAL<br />

HID<br />

CAP<br />

LAMP<br />

LINE V<br />

LAMP<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

WELDED BRACKET DIMENSIONS<br />

COM<br />

CAP<br />

LINE V<br />

LINE V<br />

COM<br />

Fig. K<br />

COM<br />

LAMP<br />

LINE V<br />

COM<br />

CAP<br />

CAP<br />

CAP<br />

Fig. M<br />

COM<br />

LAMP<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

2 6.5 1.25 5.75 0.28<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

6-19


HID<br />

HIGH INTENSITY DISCHARGE BALLASTS<br />

50 HZ Core & Coil <strong>Ballasts</strong><br />

(Minimum Starting Temperature –20°F or –30°C)<br />

Metal Halide<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max<br />

Input<br />

Current<br />

•<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

70 Watt Lamp, ANSI Code M98 or M143<br />

120/<br />

220/240 71A52N2 HX-HPF 95 1.7/<br />

256<br />

1.0/.9<br />

Fuse<br />

Rating<br />

(Amps)<br />

5/<br />

3/3<br />

Wiring<br />

Dia<br />

K<br />

Dimensions<br />

Fig<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

1 1.5 2.8 14 280 7C140M33-R D 5.0 LI533-H4<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

15<br />

U.L. Bench Top<br />

Rise Code 1029<br />

(Pg 5-3)<br />

ADVANCE<br />

Class H<br />

Class N<br />

(180°C)<br />

(200°C)<br />

B/<br />

A/B<br />

—<br />

New<br />

New<br />

INTERNATIONAL<br />

HID<br />

New<br />

N<br />

N<br />

120/<br />

220/240 71A53N0 HX-HPF 129 2.2/<br />

1.2/1.1<br />

120/<br />

220-240 71A55N0 CWA 210 2.0/<br />

1.0<br />

310<br />

250 Watt Lamp, ANSI Code M58 or H37<br />

120/<br />

220-240 71A57N0 CWA 290 2.5/<br />

315<br />

1.3<br />

320 Watt Lamp, ANSI Code M132 or M154 (Pulse-Start)<br />

120/<br />

220-240 71A58N2 Super<br />

CWA<br />

365<br />

394<br />

454<br />

3.1/<br />

1.6<br />

3.3/<br />

1.7<br />

3.9/<br />

2.0<br />

280<br />

350 Watt Lamp, ANSI Code M131 (Pulse-Start)<br />

120/<br />

220-240 71A59N3 Super<br />

CWA<br />

280<br />

400 Watt Lamp, ANSI Code M59 or H33<br />

120/<br />

220-240 71A60N1 CWA 462 4.1/<br />

320<br />

2.1<br />

400 Watt Lamp, ANSI Code M135 or M155 (Pulse-Start)<br />

120/<br />

220-240 71A60N2 Super<br />

CWA<br />

270<br />

1000 Watt Lamp, ANSI Code M47 or H36<br />

120/<br />

220/240 71A65N2 CWA 1090 9.3/<br />

450<br />

5.0/4.5<br />

1500 Watt Lamp, ANSI Code M48<br />

280<br />

150 Watt Lamp, ANSI Code M102 or M142<br />

120/<br />

220/240 71A54N2 HX-HPF 187 3.7/<br />

248<br />

2.0/1.8<br />

175 Watt Lamp, ANSI Code M57 or H39; or 150 Watt Lamp, ANSI Code M107<br />

200 Watt Lamp, ANSI Code M136 (Pulse-Start)<br />

120/<br />

220-240 71A56N3 Super<br />

CWA<br />

7/<br />

4<br />

10/<br />

5/5<br />

250 Watt Lamp, ANSI Code M138 or M153 (Pulse-Start)<br />

120/<br />

220-240 71A57N2 Super<br />

CWA<br />

244<br />

294<br />

2.1/<br />

1.1<br />

2.6/<br />

1.4<br />

280<br />

5/<br />

3<br />

7/<br />

4<br />

10/<br />

5<br />

10/<br />

5<br />

10/<br />

6<br />

10/<br />

5<br />

24/<br />

13/13<br />

1000 Watt Lamp, ANSI Code M141 (Pulse-Start)<br />

120/<br />

220/240 71A65N3 Super<br />

CWA 1090 9.3/<br />

5.0/4.5<br />

285<br />

450<br />

5/<br />

3<br />

6/<br />

3<br />

24/<br />

13/13<br />

K<br />

K<br />

A<br />

M<br />

A<br />

M<br />

M<br />

M<br />

A<br />

M<br />

A<br />

M<br />

A/<br />

1 1.9 3.2 17.5 300 7C175M33-R D 6.0 LI533-H4 15<br />

—<br />

A<br />

C/<br />

1 2.5 4.1 28 240 7C280P30-R D 7.5 LI533-H4 5<br />

—<br />

C/D<br />

1 2.8 4.0 12 450 MD1204-100 O 9.0 —<br />

A/<br />

2 1.9 3.4 17 400 7C180P40-R D 12.5 LI533-H4 2<br />

—<br />

A<br />

2 1.9 3.4 18 400 7C180P40-R D 11.5 —<br />

C/<br />

2 1.8 3.3 20 330 7C200P33-R D 11.5 LI533-H4 5<br />

—<br />

C<br />

2 2.1 3.8 24 400 7C240P40-R D 12.5 LI533-H4<br />

2 2.1 3.8 25.5 400 7C255P40-R D 12.5 LI533-H4<br />

2 2.2 3.7 24 450 MD2409-100 O 14.0 —<br />

2 2.1 3.8 30 345 7C300S34 D 12.3 LI533-H4<br />

8 3.0 5.0 26 525 MD2602-100 O 23.0 —<br />

8 3.0 5.0 26 525 MD2602-100 O 23.0 LI571-H5★<br />

2 Capacitor Set:<br />

MD1802-200<br />

(2) 18mFd Caps<br />

Connected in Parallel<br />

220/240 71A67R2 CWA 1605 7.5/6.9 450 20/20 A 8a 4.4 6.4 36 540<br />

O 32.0 —<br />

[ ]<br />

—<br />

—<br />

2<br />

2<br />

—<br />

2<br />

—<br />

2<br />

—<br />

C/<br />

C<br />

D/<br />

A<br />

A/<br />

A<br />

C/<br />

C<br />

D/<br />

D<br />

C/<br />

E<br />

D/<br />

C/C<br />

D/<br />

C/C<br />

E/E<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

A/A<br />

See Wiring Diagrams on Page 6-21<br />

6-20<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


HIGH INTENSITY DISCHARGE BALLASTS<br />

50 HZ Core & Coil <strong>Ballasts</strong><br />

(Minimum Starting Temperature –40°F or –40°C)<br />

HID<br />

High Pressure Sodium<br />

Input<br />

Volts<br />

Cap Catalog<br />

Number<br />

50 Watt Lamp, ANSI Code S68<br />

220/240 71A78R1 HX-HPF 66 .6/.5 120 2/2 K 1 1.3 2.6 6.0 280 7C060L33 D 5.0 LI551-H4 2 A/A<br />

70 Watt Lamp, ANSI Code S62<br />

120/<br />

220/240<br />

71A79N1 HX-HPF 94<br />

100 Watt Lamp, ANSI Code S54<br />

120/<br />

220/240<br />

71A80N1 HX-HPF 130<br />

150 Watt Lamp, ANSI Code S55<br />

120/<br />

220/240<br />

1.4/<br />

0.8/.7<br />

2.4/<br />

1.3/1.2<br />

125<br />

120<br />

4/<br />

2/2<br />

6/<br />

4/4<br />

1 1.9 3.1 8.4 280 7C084L33-R D 6.0 LI551-H4 2<br />

1 2.4 3.7 12 280 7C120M33-R D 8.0 LI551-H4 2<br />

1 3.0 4.2 17.5 260 7C175M33-R D 7.5 LI551-H4 2<br />

150 Watt Lamp, ANSI Code S56<br />

220/240 71A81R6 R-HPF 175 1.4/1.5 230 4/4 G 4 2.2 3.7 20 240 7C200P33-R D 6 LI501-H4 2 B/C<br />

250 Watt Lamp, ANSI Code S50<br />

120/<br />

220-240<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

71A81N2 HX-HPF 188<br />

71A82N1 CWA 300<br />

400 Watt Lamp, ANSI Code S51<br />

Max<br />

Input<br />

Current<br />

3.0/<br />

1.7/1.6<br />

2.8/<br />

1.4<br />

•<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

120<br />

190<br />

Fuse<br />

Rating<br />

(Amps)<br />

8/<br />

5/4<br />

7/<br />

4<br />

Wiring<br />

Dia<br />

K<br />

K<br />

K<br />

M<br />

Dimensions<br />

Fig<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

2 2.1 3.7 40 240 7C400P30-R D 12.0 LI501-H4 2<br />

U.L. Bench Top<br />

Rise Code 1029<br />

(Pg 5-3)<br />

ADVANCE<br />

Class H<br />

Class N<br />

(180°C)<br />

(200°C)<br />

A/<br />

A/A<br />

A/<br />

A/A<br />

C/<br />

B/B<br />

D/<br />

C<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

120/<br />

220-240<br />

71A84N3<br />

4.0/<br />

10/<br />

CWA 465<br />

190<br />

M 2 2.5 4.1 64 280<br />

2.0<br />

6<br />

7C640S28-R<br />

D<br />

15.0<br />

LI501-H4<br />

2<br />

D/<br />

D<br />

—<br />

N<br />

2 Capacitor Set:<br />

MD1408-230<br />

(2) 14mFd Caps<br />

Connected in Parallel<br />

220/240 71A87R3 CWA 1100 6.0/5.6 435 15/15 M 8a 4.3 6.3 28 580<br />

O 35.5 LI571-H5★ 2 E/E<br />

✝ Ordering information:<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-510D includes core & coil with welded bracket and dry-film capacitor<br />

-500 includes core & coil with oil-filled capacitor<br />

-510 includes core & coil with welded bracket and oil-filled capacitor<br />

-600 core & coil only (no capacitor)<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />

Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />

is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />

for additional information.<br />

• For HX and R circuits, figure is highest of starting, operating or open circuit<br />

current. For CWA circuits, figure is operating current.<br />

★ Equipped with an auto-reset thermal protector to prevent<br />

ignitor from overheating in the event of lamp failure.<br />

N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />

Refer to page 5-3 for additional information.<br />

3 7 /8"<br />

1000 Watt Lamp, ANSI Code S52<br />

B<br />

MAX.<br />

4 3 /8" 4 3 /4"<br />

A<br />

4 1 /4"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

Fig. 2<br />

(4¹₄" 1 /4" x 44³₄" 3 /4" core)<br />

B<br />

MAX.<br />

4 3 /32"<br />

A<br />

2 5 /32"<br />

Fig. 6<br />

(2" x 44" " core)<br />

B<br />

MAX.<br />

3 7 /8"<br />

4 1 /4"<br />

4 3 /8"<br />

5 3 /8" 6 "<br />

2 7 /16"<br />

A<br />

B<br />

MAX.<br />

3 1 /2" 3 15 /16"<br />

8 Holes cleared for<br />

#10 thru-bolts<br />

Fig. Fig. 8 and 8 8a<br />

(4(4¹₄" 1 /4" x 6" core)<br />

[ ]<br />

A<br />

2 13 /16"<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

Fig. 1<br />

(3" x 4" core)<br />

2 1 /4"<br />

2 13 /16"<br />

WELDED BRACKET DIMENSIONS<br />

2 13 /16"<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1 5.1 1.00 4.50 0.25<br />

2 6.5 1.25 5.75 0.28<br />

8 7.8 2.75 6.13 0.25<br />

8a 7.8 4.50 6.75 0.31<br />

B<br />

A<br />

4 Holes cleared for<br />

#10 thru-bolts<br />

3 3 /8"<br />

Fig. 4<br />

13 /16 " x 3 3 /8<br />

(2¹³₁₆" x 3³₈ Reactor Core Core) )<br />

A/A<br />

INTERNATIONAL<br />

HID<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

6-21


HID<br />

100/200V 60 HZ CORE & COIL BALLASTS<br />

For Southern Japan<br />

(Minimum Starting Temperature –20°F or –30°C)<br />

Mercury<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

U.L.<br />

Bench<br />

Top Rise<br />

Code<br />

1029<br />

(Pg 5-3)<br />

INTERNATIONAL<br />

HID<br />

N<br />

100 Watt Lamp, ANSI Code H38 or H44<br />

100/200 71A25Y1 CWA 120 1.3/.7 250 4/2 A 1 1.1 2.3 10 280 7C100M33-R D 4.0 D/E<br />

Metal Halide<br />

Input<br />

Volts<br />

Catalog✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max•<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Cap Catalog<br />

Number<br />

35/39 Watt Lamp, ANSI Code M130<br />

100 71A50Y5-P HX-HPF 54 1.1 235 2 K 6 .9 1.8 36 120 7C360M12 D 3.5 LI533-H4<br />

70 Watt Lamp, ANSI Code M98 or M143<br />

100/200 71A52Y2 HX-HPF 89 2.0/1.0 253 5/3 K 1 1.5 1.7 10 280 7C100M33-R D 4.5 LI533-H4 10 A/A —<br />

70 Watt Lamp, ANSI Code M139 (Philips CDM70/T6, CDM70/TD)<br />

100/200 71A52Y1 HX-HPF 92 2.3/1.2 255 6/3 K 1 1.5 2.7 10 330 7C100M33-R D 4.8 LI533-H4 10 A/A —<br />

100 Watt Lamp, ANSI Code M90<br />

100/200 71A53Y3 CWA 126 1.3/.7 233 3/2 M 1 1.6 1.8 10 300 7C100M33-R D 5.0 LI533-H4<br />

150 Watt Lamp, ANSI Code M102 or M142<br />

100/200 71A54Y2 HX-HPF 185 4.4/2.2 240 10/5 K 1 2.5 4.1 16 280 7C160M33 D 7.5 LI533-H4<br />

175 Watt Lamp, ANSI Code M57 or H39; or 150 Watt Lamp, ANSI Code M107<br />

100/200 71A55Y0 CWA 210 2.2/1.1 295 5/3 A 1 2.4 3.5 10 400 7C100M40-R D 7.1 —<br />

250 Watt Lamp, ANSI Code M58 or H37<br />

100/200 71A57Y0 CWA 285 3.0/1.5 295 8/4 A 2 1.7 3.1 15 400 7C150M40-R D 10.0 — — A/A<br />

320 Watt Lamp, ANSI Code M132 or M154 (Pulse-Start)<br />

Super<br />

100/200 71A58Y2<br />

368 3.7/1.9 267 10/5 M 2 1.8 3.7 21 345 7C210P34-R D 11.0 LI533-H4 5 B/B<br />

CWA<br />

400 Watt Lamp, ANSI Code M59 or H33<br />

100/200 71A60Y1 CWA 458 5.0/2.5 295 15/7 A 2 2.1 3.6 24 400 7C240P40-R D 12.0 — — C/D<br />

1000 Watt Lamp, ANSI Code M47 or H36<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

7C400P30-R<br />

200 71A65Y6 CWA 1090 5.9 425 15 P 8 3.2 5.0 20 560<br />

D 23.0 —<br />

(Two in Series)<br />

Fig<br />

A<br />

B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Dry<br />

or<br />

Oil<br />

Total<br />

Weight<br />

(Ibs)<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Part<br />

Number<br />

Max<br />

Dist<br />

To<br />

Lamp<br />

(ft)<br />

15<br />

5<br />

10<br />

—<br />

—<br />

U.L. Bench Top<br />

Rise Code 1029<br />

(Pg 5-3)<br />

ADVANCE<br />

Class H<br />

Class N<br />

(180°C)<br />

(200°C)<br />

100/200 71A50Y1 HX-HPF 53 1.3/.7 248 3/2 K 1 .9 2.0 10 280 7C100M33-R D 3.0 LI533-H4 5 A/A —<br />

B<br />

B/B<br />

C/A<br />

B/B<br />

E<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

A<br />

B<br />

MAX.<br />

3 7 /8"<br />

1 /4"<br />

A<br />

4 3 /8"<br />

5 3 /8" 5 3 /4"<br />

8 Holes cleared for<br />

#10 thru-bolts<br />

1 1 /4"<br />

Fig. 3<br />

(4 1 /4" x 5 3 /4" core)<br />

WELDED BRACKET DIMENSIONS<br />

Ballast<br />

Dimensions Fig<br />

L W M S<br />

1, 6 5.1 1.00 4.50 0.25<br />

2 6.5 1.25 5.75 0.28<br />

3, 8 7.8 2.75 6.13 0.25<br />

For Figures 1, 2, 6 and 8 – See Page 6-21<br />

6-22<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


100/200V 50 HZ CORE & COIL BALLASTS<br />

For Northern Japan<br />

(Minimum Starting Temperature –20°F or –30°C)<br />

HID<br />

Mercury<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Wiring<br />

Dia<br />

Dimensions<br />

Fig A B<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

Min<br />

Volt<br />

Cap Catalog<br />

Number<br />

Dry<br />

or<br />

Oil<br />

U.L.<br />

Bench<br />

Total<br />

Top Rise<br />

Weight<br />

Code<br />

(Ibs)<br />

1029<br />

(Pg 5-3)<br />

100 Watt Lamp, ANSI Code H38 or H44<br />

100/200 71A25M1 CWA 125 1.3/.7 250 4/2 A 1 1.3 2.6 12 300 7C120M33-R D 4.5 A/A<br />

Metal Halide<br />

Input<br />

Volts<br />

Catalog ✝<br />

Number<br />

Circuit<br />

Type<br />

Watts<br />

Input<br />

35/39 Watt Lamp, ANSI Code M130<br />

Max •<br />

Input<br />

Current<br />

Nom<br />

Open<br />

Circuit<br />

Voltage<br />

Fuse<br />

Rating<br />

(Amps)<br />

Cap Catalog<br />

Number<br />

100/200 71A50M1 HX-HPF 54 1.3/.7 250 3/2 K 1 1.1 2.2 12 280 7C120M33-R D 3.9 LI533-H4<br />

70 Watt Lamp, ANSI Code M98 or M143<br />

Wiring<br />

Dia<br />

Dimensions<br />

100/200 71A52M2 HX-HPF 90 1.9/1.0 258 5/3 K 1 1.5 1.7 14 280 7C140M33-R D 4.5 LI533-H4<br />

100/200 71A55M0 CWA 215 2.2/1.1 295 5/3 A 1 3.0 4.2 12 450 MD1204-100 O 9.0 —<br />

Fig<br />

A<br />

COM<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

B<br />

CAP<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

Mfd<br />

Non-PCB Capacitor<br />

(Page 5-48 to 5-49)<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

Min<br />

Volt<br />

CAP<br />

Fig. A<br />

Fig. K<br />

CAP<br />

COM<br />

LAMP<br />

COM<br />

LAMP<br />

LAMP<br />

LAMP<br />

Dry<br />

or<br />

Oil<br />

LINE V<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

Total<br />

Weight<br />

(Ibs)<br />

LINE V<br />

LINE V<br />

LINE V<br />

COM<br />

CAP<br />

Ignitor ✝✝<br />

(Page 5-50 to 5-53)<br />

Max<br />

Dist<br />

Part<br />

To<br />

Number<br />

Lamp<br />

(ft)<br />

70 Watt Lamp, ANSI Code M139 (Philips CDM70/T6, CDM70/TD)<br />

100/200 71A52M1 HX-HPF 90 1.9/1.0 235 5/3 K 1 1.5 3.0 14 300 7C140M33-R D 5.0 LI533-H4<br />

100 Watt Lamp, ANSI Code M90<br />

100/200 71A53M0 HX-HPF 129 2.9/1.5 280 7/4 K 1 1.9 3.2 20 240 7C200P33-R D 5.8 LI533-H4<br />

150 Watt Lamp, ANSI Code M102 or M142<br />

100/200 71A54M2 HX-HPF 185 4.4/2.2 240 10/5 K 1 2.5 4.1 35 240 7C350P24 D 7.5 LI533-H4<br />

175 Watt Lamp, ANSI Code M57 or H39; or 150 Watt Lamp, ANSI Code M07<br />

250 Watt Lamp, ANSI Code M58 or H37<br />

100/200 71A57M0 CWA 292 3.0/1.5 295 8/4 A 2 1.9 3.4 18 400 7C180P40-R D 11.0 — — A/A<br />

320 Watt Lamp, ANSI Code M132 (Pulse-Start)<br />

100/200 71A58M2<br />

Super<br />

CWA<br />

400 Watt Lamp, ANSI Code M59 or H33<br />

100/200 71A60M2 CWA 460 5.0/2.5 295 15/7 A 3 2.4 4.0 26 525 MD2602-100 O 14.0 — — C/D<br />

CAP<br />

CAP<br />

CAP<br />

Fig. P<br />

Fig. M<br />

COM<br />

CAP<br />

5<br />

15<br />

2<br />

—<br />

LAMP 1<br />

LAMP 2<br />

LAMP<br />

U.L.<br />

Bench<br />

Top<br />

Rise<br />

Code<br />

1029<br />

(pg 5-3)<br />

370 3.7/1.9 280 10/5 M 2 2.1 3.9 24 400 7C240P40-R D 12.7 LI533-H4 2 A/B<br />

✝ Ordering information:<br />

Original equipment ballasts - add proper suffix to catalog number:<br />

-500D includes core & coil with dry-film capacitor<br />

-500 includes core & coil with oil-filled capacitor<br />

✝✝ Each ballast requiring an ignitor is furnished as standard with the<br />

Short Range ignitor model shown for use within fixtures. If a<br />

Long Range ignitor is required for remote mounting, specify on<br />

order. See pages 5-50 to 5-53 for additional information.<br />

• For HX circuits, figure is highest of starting,<br />

operating or open circuit current. For CWA<br />

circuits, figure is operating current.<br />

N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />

Refer to page 5-3 for additional information.<br />

5<br />

10<br />

A/A<br />

A/A<br />

A/A<br />

A/A<br />

D/D<br />

A/A<br />

LAMP<br />

LAMP<br />

INTERNATIONAL<br />

HID<br />

6-23


XITANIUM LED ELECTRONIC DRIVERS<br />

LED Drivers are specialized power supplies serving as both brain and muscle for solid-state lighting<br />

systems. <strong>Advance</strong> is the R&D leader in LED driver technology, with a wide range of innovative products<br />

available today that are integral elements of high quality, energy-efficient solid-state lighting solutions.<br />

XITANIUM<br />

LED<br />

LED 230V Driver Data Ambient Temp.<br />

Nom. Max.<br />

Certifications<br />

Max. Min.<br />

Max. Dim./<br />

Output<br />

Input Catalog<br />

Line Input Power<br />

Env.<br />

Output Output Output Voltage Min. Max.<br />

THD Wiring<br />

Current<br />

Volts Number<br />

Current Power Factor<br />

Rating<br />

Power Voltage (Vdc)<br />

(°F/°C)<br />

CE<br />

%<br />

Dia.<br />

(Adc)<br />

(°F/°C)<br />

(Amps) (Watts)<br />

(W) (Vdc)<br />

Luxeon Drivers<br />

12 1.0 2.8 - 33.0 0.35 -40/-40 140/60 230 LED230A0350C33F ✓ 0.07 15.0 20 0.9 Fig. C/05 Dry<br />

12 1.0 2.8 - 33.0 0.35 -40/-40 140/60 230 LED230A0350C33FO ✓ 0.07 15.0 20 0.9 Fig. C/05 Dry, Damp<br />

17 1.0 2.8 - 24.6 0.70 -40/-40 140/60 230 LED230A0700C24F ✓ 0.10 21.5 20 0.9 Fig. C/05 Dry<br />

17 1.0 2.8 - 24.6 0.70 -40/-40 140/60 230 LED230A0700C24FO ✓ 0.10 21.5 20 0.9 Fig. C/05 Dry, Damp<br />

25 3.0 2.8 - 24.6 1.05 -40/-40 140/60 230 LED230A1050C24F ✓ 0.30 25.5 20 0.9 Fig. B/02 Dry<br />

40 5.0 2.8 - 24.6 1.75 -40/-40 140/60 230 LED230A1750C24F ✓ 0.47 40.8 20 0.9 Fig. B/02 Dry<br />

67 10.0 2.8 - 24.0 2.80 -40/-40 140/60 230 LED230A2800C24FO ✓ 0.35 80.0 20 0.9 Fig. D/05 Dry, Damp<br />

80 10.0 2.8 - 24.0 3.15 -40/-40 140/60 230 LED230A3150C24FO ✓ 0.48 100.0 20 0.9 Fig. D/05 Dry, Damp<br />

Fig. B<br />

Diag. 02<br />

INTERNATIONAL<br />

LED DRIVERS<br />

Fig. C<br />

Diag. 05<br />

Fig. D<br />

6-24<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


Xitanium LED ELECTRONIC DRIVERS<br />

LED DRIVERS<br />

XITANIUM<br />

1<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


Xitanium LED ELECTRONIC DRIVERS<br />

CONTENTS<br />

General Driver Information.................................................................7-2<br />

Driver Specifications ..........................................................................7-3<br />

Corporate Offices<br />

(800) 322-2086<br />

Customer Support/Technical Service<br />

(800) 372-3331 • (+) 1 847 390-5000 (International)<br />

LED DRIVERS<br />

XITANIUM<br />

Visit our web site at www.advancetransformer.com<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 7-1


LED<br />

Xitanium LED ELECTRONIC DRIVERS<br />

CENTIUM ®<br />

LED Driver Data<br />

Min. / Max.<br />

Input Input<br />

Certifications<br />

Max. Dim./<br />

Output Output Output Ambient Input Catalog<br />

Current Power Power<br />

THD Wiring<br />

Power (W) Voltage Current Temperature Volts Number<br />

Max Max Factor<br />

UL48<br />

%<br />

Dia.<br />

Max. Min.<br />

(V)<br />

(Amps) (°C / °F)<br />

(A) (W)<br />

Luxeon Drivers<br />

10.0 1.0 2.8 ~ 28.0 0.35 -40/-40 120 LED120A0350C28FO ✔ ✔ ✔ 0.12 12.5 20 0.9 Fig. A/01<br />

12.0 1.0 2.8 ~ 32.6 0.35 120 LED120A0350C33F ✔ ✔ ✔ 0.14 15.0 20 0.9 Fig. A/01<br />

17.2 2.0 2.8 ~ 24.6 0.70 120 LED120A0700C24F ✔ ✔ ✔ 0.20 21.5 20 0.9 Fig. A/02<br />

17.2 2.0 2.8 ~ 24.6 0.70<br />

-40°C / 60°C<br />

120 LED120A0700C24FO ✔ ✔ ✔ 0.20 21.5 20 0.9 Fig. A02<br />

25.5 3.0 2.8 ~ 24.6 1.05<br />

-40°F / 140°F<br />

120 LED120A0024V10F ✔ ✔ ✔ 0.30 31.9 20 0.9 Fig. B/01<br />

40.8 5.0 2.8 ~ 24.6 1.75 120 LED120A0024V18F ✔ ✔ ✔ 0.47 51.0 20 0.9 Fig. B/01<br />

- 120 ✔ ✔ ✔ 0.98 Fig. D/05<br />

100.0 0.1 2.8 ~ 24.0 4.16 230 LEDINTA0024V41FO 0.51 117.0 20 0.9 Fig. D/05<br />

- 277 ✔ ✔ ✔ 0.42 Fig. D/05<br />

12VDC LED Systems<br />

12.0 2.0 12 - -40/-40 120 LED120A0012V10F ✔ ✔ ✔ 0.13 15.0 20 0.9 Fig. C/05<br />

25.5 2.3 12 - 120 LED120A0012V21F ✔ ✔ ✔ 0.18 21.5 20 0.9 Fig. B/02<br />

60.0 10.0 12 - -40°C / 60°C 120 LED120A0012V50F ✔ ✔ ✔ 0.63 75.0 20 0.9 Fig. D/05<br />

12 - -40°F / 140°F 120 ✔ ✔ ✔ 0.61 Fig. D/05<br />

60.0 0.1 12 - 230 LEDINTA0012V50FO 0.32 73.0 20 0.9 Fig. D/05<br />

12 - 277 ✔ ✔ ✔ 0.26 Fig. D/05<br />

24VDC LED Systems<br />

17.0 2.4 24 - -40/-40 120 LED120A0024V07F ✔ ✔ ✔ 0.18 21.5 20 0.9 Fig. A/01<br />

17.0 2.4 24 - 120 LED120A0700C24FO ✔ ✔ ✔ 0.18 21.5 20 0.9 Fig. A/02<br />

25.5 2.3 24 - 120 LED120A0024V10F ✔ ✔ ✔ 0.27 31.9 20 0.9 Fig. B/02<br />

40.8 5.6 24 - -40°C / 60°C 120 LED120A0024V18F ✔ ✔ ✔ 0.43 51.0 20 0.9 Fig. B/05<br />

80.0 10 24 - -40°F / 140°F 120 LED120A0024V33F ✔ ✔ ✔ 0.83 100.0 20 0.9 Fig. D/05<br />

- 120 ✔ ✔ ✔ 0.98 Fig. D/05<br />

100.0 0.1 24 - 230 LEDINTA0024V41FO 0.51 117.0 20 0.9 Fig. D/05<br />

- 277 ✔ ✔ ✔ 0.42 Fig. D/05<br />

Dimming (0-10V Dimming)<br />

25.5 15 10.4 ~ 24.6 1.05 -40/-40 -40°C / 60°C 120 LED120A0024V10D* ✔ ✔ ✔ 0.30 31.9 20 0.9 Fig. B/03<br />

25.5 15 24 - -40°F / 140°F 120 LED120A0024V10D* ✔ ✔ ✔ 0.27 31.9 20 0.9 Fig. B/03<br />

Env.<br />

Rating<br />

Dry, Damp<br />

Dry<br />

Dry<br />

Dry, Damp<br />

Dry<br />

Dry<br />

Dry, Damp<br />

Dry, Damp<br />

Dry<br />

Dry, Damp<br />

Dry, Damp<br />

Dry<br />

Dry, Damp<br />

Dry<br />

Dry<br />

Dry<br />

Dry, Damp<br />

Dry<br />

Dry<br />

* For complete specifications on dimming driver, see <strong>Advance</strong>, Form No. LE-6010 available at www.ledcentral.com<br />

LED DRIVERS<br />

XITANIUM<br />

7-2<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


Xitanium LED ELECTRONIC DRIVERS<br />

LED<br />

Diag. 01<br />

Fig. A<br />

Diag. 02<br />

Fig. B<br />

Diag. 03<br />

Fig. C<br />

Diag. 05<br />

LED DRIVERS<br />

XITANIUM<br />

Fig. D<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />

7-3


REFERENCE MATERIALS<br />

Contents<br />

<strong>Advance</strong> Warranty ...............................................................................8-ii<br />

Industry Terms..........................................................................8-1 to 8-3<br />

Ballast Specifications ............................................................8-4 to 8-22<br />

Fixed Light Output <strong>Electronic</strong> (<strong>Section</strong> I) .........................8-5 to 8-16<br />

Controlled Light Output <strong>Electronic</strong> (<strong>Section</strong> II) ..............8-17 to 8-19<br />

HID (<strong>Section</strong> III) .........................................................................8-20<br />

<strong>Electronic</strong> HID [Metal Halide] (<strong>Section</strong> IV)..................................8-21<br />

Xitanium LED Drivers (<strong>Section</strong> V)...............................................8-22<br />

Compact Fluorescent Lamp Reference Guide..................................8-43<br />

Note: For Index pages, See pages 8-23 to 8-43<br />

Corporate Offices<br />

(800) 322-2086<br />

Customer Support/Technical Service<br />

(800) 372-3331 • (+) 1 847 390-5000 (International)<br />

Visit our web site at www.advancetransformer.com<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-i


WARRANTY<br />

ADVANCE ® Lamp Ballast Limited Warranty<br />

<strong>Advance</strong> Transformer Co. (“<strong>Advance</strong>”), 10275 W. Higgins Road, Rosemont, IL 60018 warrants that its lamp ballasts will be<br />

free from defects in material and workmanship from the date of manufacture by <strong>Advance</strong> for the following periods.<br />

(2) Years<br />

Standard Magnetic Fluorescent<br />

High Intensity Discharge (HID)<br />

Magnetic Fluorescent & HID Sign<br />

Matchbox (case temperature 65°C or less)<br />

AmbiStar (case temperature 65°C or less)<br />

(3) Years<br />

Mark III Magnetic Fluorescent<br />

E-PAK Magnetic Fluorescent<br />

Centium® <strong>Electronic</strong> 90C T5/HO (case temperature between 71°C and 90°C)<br />

SmartMate® Compact Fluorescent (case temperature between 76°C and 85°C)<br />

<strong>Electronic</strong> Sign (case temperature 90°C or less)<br />

e-Vision® <strong>Electronic</strong> HID (case temperature between 76°C and 85°C)<br />

(5) Years<br />

Standard <strong>Electronic</strong> (case temperature 70°C or less)<br />

Centium® <strong>Electronic</strong> (case temperature 70°C or less)<br />

Centium® <strong>Electronic</strong> 90C T5/HO (case temperature 70°C or less)<br />

Optanium <strong>Electronic</strong> (case temperature 70°C or less)<br />

Mark 5 <strong>Electronic</strong> (case temperature 70°C or less)<br />

SmartMate® Compact Fluorescent (case temperature 75°C or less)<br />

PowrKut® Low Frequency <strong>Electronic</strong> (case temperature 90°C or less)<br />

Mark 7 0-10V <strong>Electronic</strong> Dimming (case temperature 70°C or less)<br />

Mark 10 Powerline <strong>Electronic</strong> Dimming (case temperature 70°C or less)<br />

ROVR <strong>Electronic</strong> Dimming (case temperature 70°C or less)<br />

e-Vision® <strong>Electronic</strong> HID (case temperature 75°C or less)<br />

Xitanium® LED Drivers<br />

This warranty is conditioned upon proper storage, installation,<br />

use and maintenance. This warranty is not applicable<br />

to any ballast which is not installed and operated in accordance<br />

with the current edition of The National <strong>Electric</strong> Code<br />

(NEC), the Standards for Safety of Underwriters’<br />

Laboratory, Inc. (UL), the Standards for the American<br />

National Standards Institute (ANSI), and with <strong>Advance</strong>’s<br />

instructions and guidelines for the ballast. This warranty is<br />

not applicable to any ballast subjected to abnormal stresses<br />

and operating conditions.<br />

<strong>Advance</strong> shall correct any defects, at <strong>Advance</strong>’s option,<br />

by either repairing any defective part or parts or by replacing<br />

any defective part or parts or by making available a new<br />

replacement ballast.<br />

The conditions of any tests concerning any ballast which<br />

is claimed to have not performed to this warranty shall be<br />

mutually agreed upon in writing and <strong>Advance</strong> shall be notified<br />

of, and may be represented at any such tests. This<br />

express limited warranty is extended by <strong>Advance</strong> only to the<br />

original or first end-user purchaser.<br />

Warranty claims are to be made in accordance with<br />

<strong>Advance</strong>’s published Warranty Service Program.<br />

NO IMPLIED STATUTORY WARRANTY OF MER-<br />

CHANTABILITY OR FITNESS FOR A PARTICULAR PUR-<br />

POSE SHALL APPLY BEYOND THE AFOREMENTIONED<br />

WARRANTY PERIOD. The foregoing warranty is exclusive<br />

of all other statutory, written or oral warranties, and no<br />

other warranties of any kind, statutory or otherwise, are<br />

given or herein expressed. This warranty sets forth<br />

<strong>Advance</strong>’s responsibilities regarding the ballast and<br />

claimant’s exclusive remedy.<br />

LIMITATION OF LIABILITY. <strong>Advance</strong> will not under any<br />

circumstances whether as a result of breach of contract,<br />

breach of warranty, tort, strict liability or otherwise be liable<br />

for consequential, incidental, special or exemplary damages<br />

including but not limited to, loss of profits or revenues, loss<br />

of use of ballast or any other goods or associated equipment<br />

or damage to any associated equipment, cost of capital,<br />

cost of substitute products, facilities of services, down<br />

time cost, or claims of claimant’s customers.<br />

<strong>Advance</strong>’s liability on any claim of any kind for any loss<br />

or damages arising out of, resulting from or concerning any<br />

aspect of this agreement of from the product or services<br />

furnished hereunder shall not exceed the price of the specific<br />

ballast or ballasts which gives rise to the claim.<br />

This warranty gives the claimant specific legal rights.<br />

The claimant may also have other rights which vary from<br />

state to state.<br />

REFERENCE<br />

MATERIALS<br />

8-ii<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDUSTRY TERMS<br />

5-Tap - An HID ballast that allows for a choice of five different input<br />

voltages<br />

AC (Alternating Current) - The common form of electricity from<br />

power plant to home/office. Its direction is reversed 60 times per<br />

second in the U.S.; 50 times in Europe<br />

AllnGaP - The preferred LED (Light Emitting Diode) chip technology<br />

containing Aluminum, Indium, Gallium, and Phosphorous to produce<br />

red, orange and amber-colors.<br />

Ambient Sound Levels - "Background noise" generated by electrical<br />

equipment operating in a building.<br />

Ambient Temperature - Temperature of the atmosphere of the surrounding<br />

environment.<br />

Ampere ("Amp") - A measure of electrical current<br />

ANSI (American National Standards Institute) - Group that<br />

generates voluntary product performance standards for many U.S.<br />

industries.<br />

ANSI Watts - System wattage as measured utilizing a reference ballast<br />

and lamps on a bench top in open air as prescribed by ANSI<br />

C82.2<br />

Anti-Arc Circuit - Circuitry used to detect and limit arcing of ballast<br />

output leads<br />

Anti-Striation Circuit - Circuitry used to prevent striations or spiraling<br />

in energy saving lamps due to low temperature or low current<br />

operation<br />

Arc (Lamp) - Intense luminous discharge formed by the passage of<br />

electric current across a space between electrodes.<br />

Auto-Restrike - Circuitry used to restart the lamps without resetting<br />

the power to the ballast<br />

Autotransformer - Tapped winding transformer that changes the<br />

voltage available to the voltage required by a particular load<br />

Ballast - Device for starting and regulating fluorescent and high<br />

intensity discharge lamps.<br />

Ballast Cycling - Undesirable condition under which the ballast<br />

turns lamps on and off (cycles) due to the overheating of the thermal<br />

switch inside the ballast. This may be due to incorrect lamps,<br />

improper voltage being supplied, high ambient temperature around<br />

the fixture, or the early stage of ballast failure.<br />

Ballast Efficacy Factor (BEF) - Measure used to compare various<br />

lighting systems based upon light output and power input. Higher<br />

BEF is favorable. BEF = Ballast Factor x 100 / Input Watts<br />

Ballast Factor - Measure of light output from lamp operated by<br />

commercial ballast, as compared to a laboratory standard reference<br />

ballast.<br />

Ballast Losses - Power that is supplied to the ballast but is not converted<br />

into light energy.<br />

Ballast Noise "Hum" - Sound made by operating Core & Coil assemblies<br />

in both electromagnetic and electronic ballasts, generated by<br />

the vibration of laminations in the electromagnetic field that transforms<br />

the voltage and current used by discharge lamps. The sound<br />

made by high frequency electronic ballasts is lower and any noise<br />

made by models with electronic power factor correction circuits is<br />

inaudible.<br />

Ballast Regulation - The ability of a ballast to control lamp wattage<br />

(and therefore light output) when subject to changes in line voltage.<br />

Bin - In LED's, the systematic dividing of distribution of performance<br />

parameters (Flux, Color or CCT, and Vf) in to smaller groups<br />

that meet aesthetic requirements of the assembly.<br />

Binning - In LED's, the subdivision of the manufactured "distribution"<br />

into bins common operating parts (color, flux, forward voltage)<br />

Canadian Energy Standards - Indicates the ballast complies with<br />

the Canadian Energy Standards and meets the requirements of<br />

CAN/CSA-C654-M91<br />

Canadian Standards Association (CSA) - Association that generates<br />

product performance and safety standards for many Canadian<br />

industries.<br />

Capacitor - Device in ballast that stores electrical energy.<br />

Centigrade (C) - Celsius temperature scale where 0°C = 32°F and<br />

100°C = 212°F.<br />

Chip - A very small square of semi-conducting material. Also known<br />

as a die, it is the active light-emitting component of an LED.<br />

Circle E - Marking on ballast that shows compliance with Federal<br />

Ballast Energy Law (Public Law 100-357)<br />

Coil - Windings of copper or aluminum wire surrounding a core in<br />

ballast.<br />

Conformal Coating - Material that surrounds and adheres to components<br />

and protects them.<br />

Constant Wattage Autotransformer (CWA) - An HID ballast in<br />

which the primary and secondary coils are electrically connected.<br />

Core - Component of electromagnetic ballast that is surrounded by<br />

the coil and comprised of steel laminations or solid ferrite material.<br />

Core & Coil Ballast - Another term for electromagnetic ballast.<br />

Crest Factor - Ratio of peak lamp current to RMS (average) lamp<br />

current.<br />

CSA E - Marking on ballast that shows compliance with Canadian<br />

Ballast Energy Law.<br />

Cycling - See 'Ballast Cycling'<br />

DC forward current - Continuous direct current applied which is<br />

constant over time.<br />

Decibel (dB) - Unit of measurement of the volume of sounds<br />

Die - Chip: heart of the LED<br />

Digital Addressable Lighting Interface (DALI) - An industry<br />

standard digital protocol that allows components from different<br />

manufacturers (ballasts, sensors, controllers, etc.) to be mixed<br />

together seamlessly into complete systems.<br />

Diode - A two-electrode device with an anode and a cathode that<br />

passes current in only one direction. It may be designed as an electron<br />

tube or as a semiconductor device.<br />

Direct Current (DC) - An electrical current flowing steadily in one<br />

direction only.<br />

Discharge Lamp - A light producing device that depends on an electric<br />

arc, rather than a filament, to create illumination.<br />

Driver - <strong>Electronic</strong>s used to power illumination sources. Ballast.<br />

Efficacy - See 'System Efficacy'<br />

Electrode - See 'Filament'<br />

Electromagnetic Ballast - A low frequency (50 - 60 Hz.) ballast that<br />

uses a "Core & Coil" assembly to transform electrical energy (voltage<br />

and current) to start and operate fluorescent and high intensity<br />

discharge (HID) lamps.<br />

Electromagnetic Interference(EMI) - <strong>Electric</strong>al interference (noise)<br />

generated by electrical and electronic devices. Levels<br />

generated by high frequency electronic devices are subject to<br />

regulation by the Federal Communications Commission (FCC). Two<br />

classifications exist Non-Consumer (also referred to as Class A or<br />

Commercial) and Consumer (also referred to as Class B or<br />

Residential).<br />

<strong>Electronic</strong> Ballast - A ballast that, with the aid of electronic<br />

components converts 60 Hz. input voltage and current to high<br />

frequency (20 kHz to 60 kHz.) to operate fluorescent and high intensity<br />

discharge (HID) lamps.<br />

<strong>Electronic</strong> Component - A device or part employed in an electronic<br />

circuit to obtain some desired electronic action.<br />

Energy - Work done by an electrical system measured in watts.<br />

EOL Protection Circuit - For all T5 and smaller lamps, operating<br />

parameters within the ballast that, when exceeded, will shutdown<br />

the ballast<br />

ETL - Independent electrical testing laboratory, which performs ballast<br />

testing.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-1


INDUSTRY TERMS<br />

REFERENCE<br />

MATERIALS<br />

Federal Communication Commission (FCC) - The U.S. federal agency<br />

that is charged with regulating electrical interference emissions of the<br />

electromagnetic spectrum. The regulation entitled, "Part 18" deals<br />

with electromagnetic interference (EMI) from all lighting devices<br />

operating at frequencies higher than 9 kilohertz (kHz).<br />

Feedback Signal - A feedback signal, or control signal, regulates<br />

power through the LED driver to produce various effects in LEDs.<br />

Filament - Coated coil of special wire that emits electrons or light<br />

when heated.<br />

Filament Voltage - Voltage applied to heat the lamp filament coil.<br />

Fluorescent Lamp - Gas filled lamp in which light is produced by the<br />

interaction of an arc with phosphors lining the lamp's glass tube.<br />

Forward Current - Current through a diode in the direction of its<br />

greatest conduction.<br />

Forward Voltage (VF) - The voltage across a diode for a given forward<br />

current.<br />

Frequency - Rate of alteration in an AC current. Expressed in cycles<br />

per second or Hertz (Hz).<br />

Fundamental Frequency - Lowest frequency in a complex waveform.<br />

Also known as first harmonic<br />

Harmonic Distortion - A measurement of the magnitude of voltage<br />

and current harmonics as compared with the amplitude of the fundamental<br />

frequency. Harmonic distortion can be generated by a<br />

load and fed back into the AC mains, causing distortion of the sinusoidal<br />

waveform.<br />

Harmonics - Refers to components of the overall frequency, an integral<br />

multiple of the fundamental sinewave frequency.<br />

Hertz (Hz) - Unit used to measure frequency (cycles per second) of<br />

alternating current or voltage.<br />

High Frequency <strong>Electronic</strong> Ballast - In this book, refers to the operation<br />

of electronic ballasts as frequencies > 20,000 Hertz (20 kHz)<br />

High Intensity Discharge (HID) Lamp - A discharge lamp containing<br />

an arc tube in which the active elements within (mercury, sodium,<br />

etc.) becomes vaporized (a gaseous state) within the electric arc<br />

stream to produce light.<br />

High Light Output - Ballast with a nominal ballast factor of 1.18<br />

High Power Factor Ballast - A ballast in which the power factor is<br />

greater than 0.9 (90%). These ballasts require less line current than<br />

normal power factor ballast.<br />

High Reactance Autotransformer Ballast (HX) - HID ballast used<br />

when the input voltage does not meet the starting voltage requirement<br />

for a lamp. The ballast will transform the input voltage to the<br />

required level.<br />

Hot Restart Time - The time it takes a HID lamp to restart and reach<br />

90% of its light output after going from on to off to on. Typical<br />

restart times are 1 to 2 minutes for HPS and 5 to 20<br />

minutes for Metal Halide.<br />

IEC (International Electrotechnical Commission) - Organization<br />

made up of national committees from over 60 countries that sets<br />

international electrical and electronics standards<br />

IEEE (Institute of electrical and <strong>Electronic</strong>s Engineers)-<br />

Organization of engineers that establishes standards for electrical<br />

and electronics industries.<br />

Ignitor (Starter) - A device used within the ballast circuit to<br />

generate high voltage electrical pulses needed to start high<br />

pressure sodium and some metal halide lamps<br />

Illuminating Engineering Society (IES) - Recognized technical<br />

authority on the advancement of the art and science of illumination<br />

and its dissemination.<br />

InGaN - The preferred LED (Light Emitting Diode) semiconductor<br />

technology containing Indium, Gallium, and Nitrogen to produce<br />

green, blue and white-colored LED light sources.<br />

Input Power - See Input Watts<br />

Input Voltage - Voltage, provided by a power line or power<br />

supply, to the ballast or driver.<br />

Input Watts - Total power input to the ballast that includes lamp<br />

watts and ballast losses.<br />

Inrush Current - Initial surge of current when an electrical device is<br />

turned on.<br />

Instant Start Ballast - Electromagnetic or electronic lighting<br />

circuit without lamp filament heating that produces instant light.<br />

IntelliVolt - Multi-voltage feature of <strong>Advance</strong> electronic ballasts that<br />

allow the ballast to operate from a nominal input voltage range of<br />

120 - 277V at nominal frequencies of 50 or 60 Hz.<br />

Kilohertz (kHz) - One thousand Hertz (cycles per second).<br />

Laminations - Layers of steel, making up the ballast "core" that is<br />

surrounded by the coils in a core & coil ballast.<br />

Lamp - The lighting industry term for light bulb. It refers to the complete<br />

assembly including the internal parts as well as the outer bulb<br />

or tube and base(s).<br />

Lamp Current - The current delivered to the lamp by the ballast to<br />

generate light.<br />

Lamp Current Crest Factor - See "Crest Factor."<br />

Lamp Watts (Rated) - The power consumed by the lamp to generate<br />

light.<br />

Lead-Lag Slimline Ballast - Ballast that operate fluorescent lamps<br />

independently of one another. Can start lamps at 0°F.<br />

LED Driver - See 'Driver'<br />

Light - Radiant energy that can be sensed or seen by the human eye.<br />

Visible light is measured in lumens.<br />

Light Emitting Diode (LED) - A solid-state semiconductor device<br />

that converts electrical energy directly into light. On its most basic<br />

level, the semiconductor is comprised of two regions. The<br />

p-region contains positive electrical charges while the n-region contains<br />

negative electrical charges. When voltage is applied and current<br />

begins to flow, the electrons move across the n region into the<br />

p region. The process of an electron moving through the p-n junction<br />

releases energy. The dispersion of this energy produces photons<br />

with visible wavelengths.<br />

Line Current - See Ampere<br />

Low Power Factor - See 'Normal Power Factor'<br />

Low Voltage Control - DC voltage used for signaling purposes<br />

Low Watt - Ballast with a nominal ballast factor of 0.78 or less<br />

Lumens - Measurement of light emitted by a lighted lamp.<br />

Luminaire - A complete lighting fixture consisting of a lamp (or<br />

lamps), ballast(or ballasts) as required together with the parts<br />

designed to distribute the light, position and protect the lamp, and<br />

connect them to the incoming power.<br />

National <strong>Electric</strong> Code (NEC) - A nationally accepted electrical<br />

installation code developed by the National Fire Protection<br />

Association to reduce the risk of fire.<br />

National <strong>Electric</strong>al Manufacturers Association (NEMA) - U.S.<br />

based association that sets many common standards used in electrical<br />

products<br />

NOM (Normas Oficial Mexicana) - Laboratory that sets safety standards<br />

for building materials, electrical appliances and other products<br />

for Mexico.<br />

Normal Light Output - Ballast with a nominal ballast factor of 0.88<br />

for most T8 ballasts, and 1.00 for most T5 and dimming ballasts.<br />

Normal Power Factor - Ballast in which the power factor is less than<br />

0.80 (80%). These ballasts require about twice the line current of<br />

high power factor ballasts.<br />

Open Circuit Voltage [OCV] - Voltage, as measured at the lamp<br />

socket (HID or CFL) or across the lamp holders (fluorescent) when<br />

the lamp is not present, generated by the ballast needed to start a<br />

lamp when power is turned on.<br />

Operating Position or Burn Position - The orientation of an HID<br />

lamp in a lighting fixture such as base up, base down, horizontal, or<br />

universal.<br />

8-2<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDUSTRY TERMS<br />

Packaged LED - Consists of the die, a lead frame, which houses the<br />

die, the encapsulation epoxy that protectively surrounds the die, and<br />

also disperses the light.<br />

Parallel (LED) - <strong>Electric</strong>al condition where LEDs operate under the<br />

same voltage being provided by a driver.<br />

Parallel Circuit - Ballast circuit in which the lamps connected to<br />

one ballast operate independently of one another - if one lamp fails,<br />

the rest remain lit.<br />

PCB (Polychlorinated Biphenyls) - Chemical pollutant used in<br />

capacitors outlawed by the EPA in 1978. Ballast industry transitioned<br />

to non-PCB capacitors during 1979.<br />

Potting - Compound used to completely surround and cover components<br />

of some magnetic and electronic ballasts in order to protect<br />

components, dampen sound, and dissipate heat.<br />

Power - The amount of energy consumed or needed by a device<br />

(ballast, lamp, or ballast plus lamp) to perform its function. Power<br />

is measured in watts.<br />

Power Factor (PF) - A measurement of how efficiently an electrical<br />

device uses power supplied by the power line. PF = Watts / (Volts<br />

x Amps).<br />

Power Factor Corrected (PFC) - Ballast with a power factor from<br />

0.80 to 0.89<br />

Powerline Control - Method of dimming control where the phase of<br />

the sine wave is 'chopped' to dim the lamps.<br />

Preheat Ballast - Electromagnetic ballast that requires a separate<br />

starter in order to ignite the lamp<br />

Probe Start - Method of starting mercury vapor and specific metal<br />

halide lamps in which an additional electrode at one end of the arc<br />

tube assists in lamp starting.<br />

Programmed Start Ballast - An electronic lighting circuit similar to<br />

rapid start that provides precise heating of the lamp filaments and<br />

tightly controlling the preheat duration before applying starting voltage<br />

to ignite the lamp.<br />

Pulse Start - Method of starting high pressure sodium and specific<br />

metal halide lamps in which a high voltage starting pulse starts the<br />

lamps<br />

Quadri-Volt (Quad-Tap) - Feature within a ballast which gives you a<br />

choice of 4 different input voltages<br />

Rank - See 'Bin'<br />

Rapid Start Ballast - Electromagnetic or electronic ballast that provides<br />

both filament heating and starting voltage to the lamp at the<br />

same time in order to ignite the lamp.<br />

Reference Ballast (standard reactor) - Laboratory device used to<br />

provide ANSI specified measurements of initial and mean lamp<br />

lumens.<br />

Regulation, Lamp Wattage - The measure of the ability of a ballast<br />

or ballast circuit type to control (regulate) a lamp's operating<br />

wattage as the input voltage varies from nominal. It is the ratio of<br />

the percent change in line voltage (input voltage) and the resultant<br />

percent change in lamp wattage<br />

Reverse Current - Current flowing through a diode in the direction<br />

opposite to the direction of maximum conduction<br />

Reverse Voltage - Volatge across the diode for a given reverse current.<br />

RFI (Radio Frequency Interference) - Form of electromagnetic<br />

interference.<br />

Series (LED) - <strong>Electric</strong>al condition where LEDS operate under the<br />

same current being provided by a driver.<br />

Series Circuit - Ballast circuit in which the lamps connected to one<br />

ballast operate as a group. If one lamp fails or is removed, then all<br />

lamps in the circuit turn off<br />

Series-Sequence Slimline Ballast - <strong>Ballasts</strong> that operate with<br />

lamps starting in sequence.<br />

Series-Parallel Circuit - Ballast circuit in which the lamps connected<br />

to one ballast operate both as a group and independently. If one<br />

lamp fails or is removed in the series connected section, then all<br />

lamps in that section will turn off, but the lamps in the parallel circuit<br />

remain on.<br />

Sine Wave - A mathematical function used to represent voltage and<br />

current.<br />

Sound Rating - Classification given to a ballast based upon ballast<br />

noise.<br />

Starting Temperature - The minimum ambient temperature at<br />

which the lamp will start. Light output may be affected due to lamp<br />

characteristics.<br />

Striation - Spiraling or swirling of fluorescent lamps at initial turn<br />

on or energy-saving lamps at low temperature or low current.<br />

System Efficacy - Overall efficiency of the lamp/ballast system.<br />

System efficacy = total lamp lumens/system wattage<br />

Thermal Protector - A self-resetting switch that disconnects power<br />

to the ballast if internal temperatures rise above the trip point (typically<br />

105°C)<br />

Third Harmonic - Third multiple of the fundamental frequency that<br />

will add in the neutral wire of a three phase, 4 wire, Wye system and<br />

will cause over heating of the neutral wire should it exceed 33 1/3<br />

percent.<br />

Three-Phase, Four-Wire Wye - Most popular electrical wiring system<br />

used today for commercial building<br />

Total Harmonic Current (THC) - The combined effect of all of the<br />

harmonic distortion on the AC waveform produced by a ballast or<br />

other device. Excessive levels of THC can create large currents on<br />

the neutral line of a 3 phase 4 wire wye power system. See<br />

Harmonic Distortion.<br />

Total Harmonic Distortion (THD) - Total Harmonic Current (THC)<br />

expressed as a percentage.<br />

Transients - High voltage and resultant high current surges through<br />

an electrical system caused by lightning strikes to nearby transformers,<br />

overhead lines or the ground. May also be caused by<br />

switching of large motors or other electrical loads, as well as by<br />

short circuits or utility system switching. Can lead to premature failure<br />

of ballasts or other electrical devices.<br />

Trigger Start Ballast - Electromagnetic ballast that starts and operates<br />

preheat lamps similar to a rapid start lamp. No separate starter<br />

is needed to ignite the lamp.<br />

UL (Underwriters' Laboratories, Inc.) - A not for profit organization<br />

in the US that generates product performance and safety standards<br />

for electrical equipment, building materials, and other products. End<br />

use products such as lighting fixtures, fully encased ballasts, and<br />

home appliances are examples of UL Listed products and bear the<br />

UL logo. Components such as HID open core & coil ballasts, electrical<br />

insulating materials are UL Component Recognized products<br />

and bear the UL Component Recognition logo<br />

UR (UL Recognized) - A part or subassembly covered under UL's<br />

Recognition Service and intended for factory installation in UL certified<br />

products. They are intended for use as components of complete<br />

equipment submitted for investigation by UL.<br />

Voltage - A measurement of the electromotive force (electrical pressure)<br />

in an electrical circuit or device expressed in volts. Voltage can<br />

be thought of as being analogous to the pressure in a plumbing system.<br />

Voltage Sag - Drop in voltage levels of electrical distribution system<br />

that interferes with the operation of electrical and electronic equipment.<br />

Commonly called "Brownout". Results when demand for electricity<br />

exceeds capacity of the distribution system.<br />

Watt - The unit of measurement of electrical power. Watts = Volts x<br />

Amps x Power Factor<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-3


BALLAST SPECIFICATION<br />

MASTER SPEC. and CSI FORMAT<br />

BALLAST SPECIFICATION FOR LIGHTING<br />

SECTION I - FIXED LIGHT OUTPUT ELECTRONIC (FLUORESCENT)<br />

• Standard<br />

• Centium® Micro Can<br />

• Centium® T5<br />

• Centium® T8, T12 and FT5<br />

• Optanium® Dedicated Voltage<br />

• Optanium® 2.0 IntelliVolt®<br />

• Mark 5<br />

• SmartMate<br />

• Matchbox<br />

• AmbiStar<br />

• PowrKut®<br />

• PureVOLT<br />

SECTION II - CONTROLLABLE LIGHT OUTPUT ELECTRONIC (FLUORESCENT)<br />

• Mark 7 0-10V<br />

• Mark 10 Powerline<br />

•ROVR<br />

SECTION III - HID (INCLUDING METAL HALIDE, HIGH PRESSURE SODIUM, LOW<br />

PRESSURE SODUIM AND MERCURY VAPOR).<br />

SECTION IV - ELECTRONIC HID (METAL HALIDE)<br />

• e-Vision<br />

SECTION V - XITANIUM LED DRIVERS<br />

Corporate Offices<br />

(800) 322-2086<br />

Customer Support/Technical Service<br />

(800) 372-3331 • (+) 1 847 390-5000 (International)<br />

REFERENCE<br />

MATERIALS<br />

Visit our web site at www.advancetransformer.com<br />

8-4<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

Standard<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be provided with integral leads color-coded<br />

per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be __________ (Instant or Rapid) Start.<br />

2.2 Ballast shall provide Independent Lamp Operation (ILO)<br />

for Instant Start ballasts allowing remaining lamp(s) to<br />

maintain full light output when one or more lamps fail.<br />

2.3 Ballast shall contain auto restart circuitry in order to<br />

restart lamps without resetting power.<br />

2.4 Ballast shall operate from 60 Hz input source of 120V,<br />

277V or 347V as applicable with sustained variations of<br />

+/- 10% (voltage and frequency) with no damage to the<br />

ballast.<br />

2.5 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency between 20 kHz and 30 kHz or above<br />

42 kHz to avoid interference with infrared devices and<br />

eliminate visible flicker.<br />

2.6 Ballast shall have a Power Factor greater than 0.98 for<br />

primary lamp.<br />

2.7 Ballast shall have a minimum ballast factor for primary<br />

lamp application as follows: 0.75 for Low Watt, 0.85 for<br />

Normal Light Output, and 1.20 for High Light.<br />

2.8 Ballast shall provide for a Lamp Current Crest Factor of<br />

1.7 or less in accordance with lamp manufacturer recommendations.<br />

2.9 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 20% for Standard models and THD of<br />

less than 10% for Centium models when operated at<br />

nominal line voltage with primary lamp.<br />

2.10 Ballast shall have a Class A sound rating for all 4-foot<br />

lamps and smaller.<br />

2.11 Ballast shall have a minimum starting temperature of<br />

_______ [-18C (0F) for standard T8 lamps, 10C (50F) for<br />

T8/HO, standard T12, Slimline T12 and Long Twin Tube<br />

lamps, 0C (32F) for Slimline T8, -29C (-20F) for T12/HO<br />

lamps,] for primary lamp application. Ballast shall have<br />

a minimum starting temperature of 60F (16C) for energysaving<br />

T8 and T12 lamps.<br />

2.12 Ballast shall tolerate sustained open circuit and short<br />

circuit output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />

Class P and Type 1 Outdoor; and Canadian Standards<br />

Association (CSA) certified where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to ISO<br />

9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of manu<br />

facture against defects in material or workmanship,<br />

including replacement, for operation at a maximum case<br />

temperature of 70C.<br />

4.3 Manufacturer shall have a fifteen-year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />

experience lamp striations if operated on ballasts other than<br />

Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />

saving T8 lamps (25W, 28W or 30W) is only recommended for<br />

Optanium 2.0 (IOP) models.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-5


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

Centium ® Micro Can<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be provided with integral leads color-coded<br />

per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Instant Start.<br />

2.2 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.3 Ballast shall operate from 50/60 Hz input source of 120V or<br />

277V with sustained variations of +/- 10% (voltage and<br />

frequency) with no damage to the ballast. IntelliVolt models<br />

shall operate from 50/60 Hz input source of 120V through<br />

277V with sustained variations of +/- 10% (voltage and<br />

frequency) with no damage to the ballast.<br />

2.4 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz to avoid interference<br />

with infrared devices and eliminate visible flicker.<br />

2.5 Ballast shall have a Power Factor greater than 0.98 for<br />

primary lamp.<br />

2.6 Ballast shall have a minimum ballast factor for primary lamp<br />

application as follows: 0.75 for Low Watt, 0.85 for Normal<br />

Light Output, and 1.20 for High Light.<br />

2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or<br />

less in accordance with lamp manufacturer recommendations.<br />

2.8 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 20% for Standard models and THD of<br />

less than 10% for Centium models when operated at<br />

nominal line voltage with primary lamp.<br />

2.9 Ballast shall have a Class A sound rating.<br />

2.10 Ballast shall have a minimum starting temperature of -18C<br />

(0F) for standard T8 lamps and 16C (60F) for energy-saving<br />

T8 lamps.<br />

2.11 Ballast shall provide Lamp EOL Protection Circuit.<br />

2.12 Ballast shall tolerate sustained open circuit and short circuit<br />

output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />

Class P and Type 1 Outdoor; and Canadian Standards<br />

Association (CSA) certified where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of<br />

manufacture against defects in material or workmanship,<br />

including replacement, for operation at a maximum case<br />

temperature of 70C.<br />

4.3 Manufacturer shall have a fifteen-year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />

experience lamp striations if operated on ballasts other than<br />

Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />

saving T8 lamps (25W, 28W or 30W) is only recommended for<br />

Optanium 2.0 (IOP) models.<br />

REFERENCE<br />

MATERIALS<br />

8-6<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

Centium ® T5<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be provided with integral leads or poke-in wire<br />

trap connectors color-coded per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Programmed Start.<br />

2.2 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.3 Ballast shall operate from 50/60 Hz input source of<br />

___________________ (120V through 277V or 347V<br />

through 480V) with sustained variations of +/- 10% (voltage<br />

and frequency) with no damage to the ballast.<br />

2.4 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz to avoid interference<br />

with infrared devices and eliminate visible flicker.<br />

2.5 Ballast shall have a Power Factor greater than 0.98 for<br />

primary lamp.<br />

2.6 Ballast shall have a minimum ballast factor of 1.00 for<br />

primary lamp application.<br />

2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or<br />

less in accordance with lamp manufacturer recommendations.<br />

2.8 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 20% for Standard models and THD of<br />

less than 10% for Centium models when operated at<br />

nominal line voltage with primary lamp.<br />

2.9 Ballast shall have a Class A sound rating.<br />

2.10 Ballast shall have a minimum starting temperature of<br />

_______ {-18C (0F) or -28C (-20F)} for primary lamp.<br />

2.11 Ballast shall provide Lamp EOL Protection Circuit.<br />

2.12 Ballast shall tolerate sustained open circuit and short circuit<br />

output conditions without damage.<br />

2.13 Ballast shall have a hi-low switching option when operating<br />

(4) F54T5/HO lamps to allow switching from 4-2 lamps,<br />

3-2 lamps or 3-1 lamp.<br />

2.14 Four-lamp ballast shall have semi-independent lamp operation.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />

Class P and Type 1 Outdoor; and Canadian Standards<br />

Association (CSA) certified where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

3.6 Ballast shall comply with UL Type CC rating.<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of<br />

manufacture against defects in material or workmanship,<br />

including replacement, for operation at a maximum case<br />

temperature of 70C. <strong>Ballasts</strong> with a "90C" designation in<br />

their catalog number shall also carry a three-year warranty<br />

at a maximum case temperature of 90C.<br />

4.3 Manufacturer shall have a fifteen-year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-7


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

Centium ® T8, T12 & FT5<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be provided with integral leads color coded per<br />

ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be _________ (Instant, Rapid or Programmed)<br />

Start.<br />

2.2 Ballast shall provide Independent Lamp Operation (ILO) for<br />

Instant Start ballats allowing remaining lamp(s) to maintain<br />

full light output when one or more lamps fail.<br />

2.3 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power (except T8/HO ballast).<br />

2.4 Ballast shall operate from 60 Hz input source of 120V, 277V<br />

or 347V as applicable with sustained variations of +/- 10%<br />

(voltage and frequency) with no damage to the ballast.<br />

IntelliVolt models shall operate from 50/60 Hz input source<br />

of 120V through 277V with sustained variations of +/- 10%<br />

(voltage and frequency) with no damage to the ballast.<br />

2.5 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz ("GCN" models between<br />

20kHz and 30kHz) to avoid interference with infrared<br />

devices and eliminate visible flicker.<br />

2.6 Ballast shall have a Power Factor greater than 0.98 for primary<br />

lamp.<br />

2.7 Ballast shall have a minimum ballast factor for primary<br />

lamp application as follows: 0.75 for Low Watt, 0.85 for<br />

Normal Light Output, and 1.20 for High Light.<br />

2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7<br />

or less in accordance with lamp manufacturer recommendations.<br />

2.9 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 20% for Standard models and THD of<br />

less than 10% for Centium models when operated at nominal<br />

line voltage with primary lamp.<br />

2.10 Ballast shall have a Class A sound rating.<br />

2.11 Ballast shall have a minimum starting temperature of<br />

_______ [-18C (0F) for standard T8 and Long Twin Tube<br />

lamps, 10C (50F) for standard T12 lamps, 0C (32F) for<br />

Slimline T8 lamps and "GCN" models, -29C (-20F) for<br />

T8/HO lamps] for primary lamp application. Ballast shall<br />

have a minimum starting temperature of 16C (60F) for<br />

energy-saving T8 and T12 lamps.<br />

2.12 Ballast shall tolerate sustained open circuit and short<br />

circuit output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class<br />

P and Type 1 Outdoor; and Canadian Standards Association<br />

(CSA) certified where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to ISO<br />

9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of manufacture<br />

against defects in material or workmanship, including<br />

replacement, for operation at a maximum case temperature<br />

of 70C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />

experience lamp striations if operated on ballasts other than<br />

Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />

saving T8 lamps (25W, 28W or 30W) is only recommended for<br />

Optanium 2.0 (IOP) models.<br />

REFERENCE<br />

MATERIALS<br />

8-8<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

Optanium ® Dedicated Voltage<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be provided with integral leads color coded per<br />

ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Instant Start.<br />

2.2 Ballast shall provide Independent Lamp Operation (ILO) for<br />

Instant Start ballats allowing remaining lamp(s) to maintain<br />

full light output when one or more lamps fail.<br />

2.3 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.4 Ballast shall operate from 60 Hz input source of 120V, 277V<br />

or 347V as applicable with sustained variations of +/- 10%<br />

(voltage and frequency) with no damage to the ballast.<br />

2.5 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency between 42 kHz and 52kHz to avoid<br />

interference with infrared devices, eliminate visible flicker<br />

avoid Article Surveillance Systems, such as anti-theft<br />

devices.<br />

2.6 Ballast shall have a Power Factor greater than 0.98 for<br />

primary lamp.<br />

2.7 Ballast shall have a minimum ballast factor for primary<br />

lamp application as follows: 0.75 for Low Watt, 0.85 for<br />

Normal Light Output, and 1.20 for High Light.<br />

2.8 Ballast shall provide for a Lamp Current Crest Factor of<br />

1.7 or less in accordance with lamp manufacturer<br />

recommendations.<br />

2.9 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 10% when operated at nominal line voltage<br />

with primary lamp.<br />

2.10 Ballast shall have a Class A sound rating for all 4-foot<br />

lamps and smaller<br />

2.11 Ballast shall have a minimum starting temperature of<br />

-18C (0F) for standard T8 lamps and 16C (60F) for<br />

energy-saving T8 lamps.<br />

2.12 Ballast shall tolerate sustained open circuit and short<br />

circuit output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />

Class P and Type 1 Outdoor; and Canadian Standards<br />

Association (CSA) certified, where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11, where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of<br />

manufacture against defects in material or workmanship,<br />

including replacement, for operation at a maximum case<br />

temperature of 70C. <strong>Ballasts</strong> with a “90C” designation in<br />

their catalog number shall also carra a three-year warranty<br />

at a maximum case temperature of 90C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />

experience lamp striations if operated on ballasts other than<br />

Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />

saving T8 lamps (25W, 28W or 30W) is only recommended for<br />

Optanium 2.0 (IOP) models.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-9


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

Optanium ® 2.0 IntelliVolt ®<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be provided with integral leads color coded per<br />

ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be _________ (Instant or Programmed) Start.<br />

2.2 Ballast shall provide Independent Lamp Operation (ILO) for<br />

Instant Start ballats allowing remaining lamp(s) to maintain<br />

full light output when one or more lamps fail.<br />

2.3 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.4 Ballast shall operate from 50/60 Hz input source of 120V<br />

through 277V with sustained variations of +/- 10% (voltage<br />

and frequency) with no damage to the ballast.<br />

2.5 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency between 42 kHz and 52kHz to avoid<br />

interference with infrared devices, eliminate visible flicker<br />

and avoid Article Surveillance Systems, such as anti-theft<br />

devices.<br />

2.6 Ballast shall have a Power Factor greater than 0.98 for<br />

primary lamp.<br />

2.7 Ballast shall have a minimum ballast factor for primary<br />

lamp application as follows: 0.77 for Low Watt, 0.87<br />

for Normal Light Output, and 1.18 for High Light for Instant<br />

Start ballasts or 0.71 for Low Watt and 0.88 for Normal<br />

Light Output for Programmed Start ballasts.<br />

2.8 Ballast shall provide for a Lamp Current Crest Factor of<br />

1.7 or less in accordance with lamp manufacturer<br />

recommendations.<br />

2.9 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 10% when operated at nominal line voltage<br />

with primary lamp.<br />

2.10 Ballast shall have a Class A sound rating for all 4-foot<br />

lamps and smaller.<br />

2.11 Ballast shall have a minimum starting temperature of -29C<br />

(-20F) on Instant Start ballasts or -18C (0F) on<br />

Programmed Start ballasts for standard T8 lamps and 16C<br />

(60F) for energy-saving T8 lamps.<br />

2.12 Ballast shall tolerate sustained open circuit and short<br />

circuit output conditions without damage.<br />

2.13 Ballast shall contain an anti-striation circit to prevent<br />

striation on energy-saving T8 lamps.<br />

2.14 Programmed Start ballast shall provide lamp EOL<br />

protection circuitry.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />

Class P and Type 1 Outdoor; and Canadian Standards<br />

Association (CSA) certified, where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

3.6 Ballast shall comply with UL Type CC rating.<br />

3.7 Ballast shall meet NEMA/CEEE High Performance T8<br />

Lighting System Specifications.<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of<br />

manufacture against defects in material or workmanship,<br />

including replacement, for operation at a maximum case<br />

temperature of 70C. <strong>Ballasts</strong> with a "90C" designation in<br />

their catalog number shall also carry a three-year warranty<br />

at a maximum case temperature of 90C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />

experience lamp striations if operated on ballasts other than<br />

Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />

saving T8 lamps (25W, 28W or 30W) is only recommended for<br />

Optanium 2.0 (IOP) models.<br />

REFERENCE<br />

MATERIALS<br />

8-10<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

Mark 5<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be provided with integral leads color coded per<br />

ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Programmed Start.<br />

2.2 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.3 Ballast shall operate from 50/60 Hz input source of 120V<br />

through 277V with sustained variations from 90V - 305V<br />

with no damage to the ballast.<br />

2.4 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz to avoid interference<br />

with infrared devices and eliminate visible flicker.<br />

2.5 Ballast shall have a Power Factor greater than 0.98 for<br />

primary lamp.<br />

2.6 Ballast shall have a minimum ballast factor for primary<br />

lamp application as follows: 0.75 for Low Watt, 0.85 for<br />

Normal Light Output, and 1.20 for High Light.<br />

2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.5<br />

or less for primary lamp and 1.6 or less for all others.<br />

2.8 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 10% when operated at nominal line<br />

voltage with primary lamp.<br />

2.9 Ballast shall have a Class A sound rating.<br />

2.10 Ballast shall have a minimum starting temperature of<br />

-18C (0F) for standard T8 lamps and 16C (60F) for<br />

energy-saving T8 lamps.<br />

2.11 Ballast shall tolerate sustained open circuit and short<br />

circuit output conditions without damage.<br />

2.12 Ballast shall provide lamp EOL protection circuitry.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />

Class P and Type 1 Outdoor; and Canadian Standards<br />

Association (CSA) certified where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of<br />

manufacture against defects in material or workmanship,<br />

including replacement, for operation at a maximum case<br />

temperature of 70C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />

experience lamp striations if operated on ballasts other than<br />

Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />

saving T8 lamps (25W, 28W or 30W) is only recommended for<br />

Optanium 2.0 (IOP) models.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-11


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

SmartMate<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be available in a plastic/metal can or all metal<br />

can construction to meet all plenum requirements.<br />

1.3 Ballast shall be provided with poke-in wire trap connectors<br />

color coded per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Programmed Start except for ballasts with<br />

-QS suffix, which shall be Rapid Start.<br />

2.2 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.3 Ballast shall operate from 50/60 Hz input source of 120V<br />

through 277V with sustained variations of +/- 10% (voltage<br />

and frequency) with no damage to the IntelliVolt ballast.<br />

2.4 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz to avoid interference<br />

with infrared devices and eliminate visible flicker.<br />

2.5 Ballast shall have a Power Factor greater than 0.98 for<br />

primary lamp.<br />

2.6 Ballast shall have a minimum ballast factor of 1.00 for<br />

primary lamp application.<br />

2.7 Ballast shall provide for a Lamp Current Crest Factor of<br />

1.7 or less in accordance with lamp manufacturer<br />

recommendations.<br />

2.8 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 10% when operated at nominal line<br />

voltage with primary lamp.<br />

2.9 Ballast shall have a Class A sound rating.<br />

2.10 Ballast shall have a minimum starting temperature of -18C<br />

(0F) for primary lamp. <strong>Ballasts</strong> for PL-H lamps shall have<br />

a minimum starting temperature of -30C (-20F) for primary<br />

lamp.<br />

2.11 Ballast shall provide Lamp EOL Protection Circuit.<br />

2.12 Ballast shall tolerate sustained open circuit and short<br />

circuit output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polyclorinated Biphenyl (PCB)<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />

Class P and Type 1 Outdoor; and Canadian Standards<br />

Association (CSA) certified where applicable.<br />

3.3 Ballast shall be Underwriters Laboratories (UL) rated for<br />

use in air-handling spaces.<br />

3.4 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.5 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.6 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to ISO<br />

9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date<br />

of manufacture against defects in material or workmanship,<br />

including replacement, for operation at a maximum<br />

case temperature of 75C and three-years for a maximum<br />

case temperature of 85C (90C three-year warranty<br />

for ICF-1H120-M4-XX, ICF-2S42-90C-M2-XX and<br />

ICF-2S70-M4-XX models).<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

REFERENCE<br />

MATERIALS<br />

8-12<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

Matchbox<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be provided with poke-in wire trap connectors<br />

color coded per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Instant Start.<br />

2.2 Ballast shall provide Independent Lamp Operation (ILO)<br />

allowing remaining lamp(s) to maintain full light output<br />

when one or more lamps fail.<br />

2.3 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.4 Ballast shall operate from 60 Hz input source of 120V with<br />

sustained variations of +/- 10% (voltage and frequency)<br />

with no damage to the ballast.<br />

2.5 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz to avoid interference<br />

with infrared devices and eliminate visible flicker.<br />

2.6 Ballast shall have a Power Factor greater than 0.50 for<br />

primary lamp.<br />

2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7<br />

or less in accordance with lamp manufacturer recommendations.<br />

2.8 Ballast shall have a Class A sound rating.<br />

2.9 Ballast shall have a minimum starting temperature of -18C<br />

(0F) for primary lamp.<br />

2.10 Ballast shall provide Lamp EOL Protection Circuit.<br />

2.11 Ballast shall tolerate sustained open circuit and short<br />

circuit output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />

Class P, Type CC, and Type 1 Outdoor; and Canadian<br />

Standards Association (CSA) certified.<br />

3.3 Ballast shall be Underwriters Laboratories (UL) rated for<br />

use in air-handling spaces.<br />

3.4 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.5 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.6 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Consumer (Class B) for EMI/RFI (conducted<br />

and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

4.2 Ballast shall carry a two-year warranty from date of<br />

manufacture against defects in material or workmanship,<br />

including replacement, for operation at a maximum case<br />

temperature of 65C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-13


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

AmbiStar<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be provided with integral leads or poke-in wire<br />

trap connectors color coded per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be ___________ (Instant, Rapid or Quick)<br />

Start.<br />

2.2 Ballast shall provide Independent Lamp Operation (ILO) for<br />

Instant Start ballasts allowing remaining lamp(s) to maintain<br />

full light output when one or more lamps fail.<br />

2.3 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.4 Ballast shall operate from 60 Hz input source of 120V with<br />

sustained variations of +/- 10% (voltage and frequency)<br />

with no damage to the ballast.<br />

2.5 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz to avoid interference<br />

with infrared devices and eliminate visible flicker.<br />

2.6 Ballast shall have a Power Factor greater than 0.50 for primary<br />

lamp.<br />

2.7 Ballast shall provide for a Lamp Current Crest Factor of<br />

1.7 or less in accordance with lamp manufacturer<br />

recommendations.<br />

2.8 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 200% when operated at nominal line<br />

voltage with primary lamp.<br />

2.9 Ballast shall have a Class A sound rating.<br />

2.10 Ballast shall have a minimum starting temperature of<br />

_______ (-18C (0F) for standard T8 and CFL lamps, 10C<br />

(50F) for standard T12 lamps for primary lamp application<br />

and 16C (60F) for energy-saving T12 lamps.<br />

2.11 Ballast shall provide Lamp EOL Protection Circuit for CFL<br />

lamps.<br />

2.12 Ballast shall tolerate sustained open circuit and short circuit<br />

output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class<br />

P, and Type 1 Outdoor; and Canadian Standards Association<br />

(CSA) certified were applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Consumer (Class B) for EMI/RFI (conducted<br />

and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

4.2 Ballast shall carry a two-year warranty from date of<br />

manufacture against defects in material or workmanship,<br />

including replacement, for operation at a maximum case<br />

temperature of 65C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

REFERENCE<br />

MATERIALS<br />

8-14<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

PowrKut ®<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be provided with integral leads color coded per<br />

ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Rapid Start.<br />

2.2 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.3 Ballast shall operate from 60 Hz input source of 120V, 277V<br />

or 347V as applicable with sustained variations of +/- 10%<br />

(voltage and frequency) with no damage to the ballast.<br />

2.4 Ballast shall operate lamps at a frequency of 60 Hz.<br />

2.5 Ballast shall have a Power Factor greater than 0.90 for<br />

primary lamp.<br />

2.6 Ballast shall have a minimum ballast factor of 0.85 for T8 or<br />

0.80 for T12 primary lamp application.<br />

2.7 Ballast shall provide for a Lamp Current Crest Factor of<br />

1.7 or less in accordance with lamp manufacturer<br />

recommendations.<br />

2.8 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 20% when operated at nominal line<br />

voltage with primary lamp.<br />

2.9 Ballast shall have a Class A sound rating.<br />

2.10 Ballast shall have a minimum starting temperature of 10C<br />

(50F) for primary lamp and 16C (60F) for energy-saving<br />

lamps.<br />

2.11 Ballast shall tolerate sustained open circuit and short<br />

circuit output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />

Class P and Type 1 Outdoor; and Canadian Standards<br />

Association (CSA) certified where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of<br />

manufacture against defects in material or workmanship,<br />

including replacement, for operation at a maximum case<br />

temperature of 90C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />

experience lamp striations if operated on ballasts other than<br />

Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />

saving T8 lamps (25W, 28W or 30W) is only recommended for<br />

Optanium 2.0 (IOP) models.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-15


BALLAST SPECIFICATION<br />

SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for <strong>Electronic</strong> Fluorescent<br />

PureVOLT<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be available in a plastic/metal can or all metal<br />

can construction to meet all plenum requirements.<br />

1.2 Ballast shall be provided with poke-in wire trap connectors<br />

color coded per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Programmed Start<br />

2.2 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.3 Ballast shall operate from 50/60 Hz input source of 120V<br />

through 277V with sustained variations of +/- 10% (voltage<br />

and frequency) with no damage to the IntelliVolt ballast.<br />

2.4 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz to avoid interference<br />

with infrared devices and eliminate visible flicker.<br />

2.5 Ballast shall have a Power Factor greater than 0.96 for<br />

primary lamp.<br />

2.6 Ballast shall provide for a Lamp Current Crest Factor of<br />

1.7 or less in accordance with lamp manufacturer<br />

recommendations.<br />

2.7 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 10% when operated at nominal line voltage<br />

with primary lamp.<br />

2.8 Ballast shall have a Class A sound rating.<br />

2.9 Ballast shall have a minimum starting temperature of -18C<br />

(0F) for primary lamp.<br />

2.10 Ballast shall provide Lamp EOL Protection Circuit.<br />

2.11 Ballast shall tolerate sustained open circuit and short<br />

circuit output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />

Class P, and Type 1 Outdoor; and Canadian Standards<br />

Association (CSA) certified were applicable.<br />

3.3 Ballast shall be Underwriters Laboratories (UL) rated for<br />

use in air-handling spaces<br />

3.4 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.5 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.6 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of manufacture<br />

against defects in material or workmanship, including<br />

replacement, for operation at a maximum case temperature<br />

of 75C and three-years for a maximum case temperature<br />

of 85C (90C three-year warranty for IUV-2S60-M4-XX<br />

models).<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

REFERENCE<br />

MATERIALS<br />

8-16<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


BALLAST SPECIFICATION<br />

SECTION II – Controllable Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for Controllable Light Output <strong>Electronic</strong> Fluorescent<br />

Mark 7 0-10V<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be available in a plastic/metal can or all metal<br />

can construction to meet all plenum requirements.<br />

1.3 Ballast shall be provided with poke-in wire trap connectors<br />

or integral leads color coded per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Programmed Start.<br />

2.2 Ballast shall be provided with integral protection circuitry to<br />

withstand connection of low voltage control leads to mains<br />

power supply. In this event, ballast shall default to maximum<br />

light output.<br />

2.3 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.4 Ballast shall operate from 50/60 Hz input source of 120V or<br />

277V with sustained variations of +/- 10% (voltage and frequency)<br />

with no damage to the ballast. IntelliVolt models<br />

shall operate from 50/60 Hz input source of 120V through<br />

277V with sustained variations of +/- 10% (voltage and frequency)<br />

with no damage to the ballast.<br />

2.5 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz to avoid interference<br />

with infrared devices and eliminate visible flicker.<br />

2.6 Ballast shall have a Power Factor greater than 0.98 at full<br />

light output and greater than 0.90 throughout the dimming<br />

range for primary lamp.<br />

2.7 Ballast shall have a minimum ballast factor of 1.00 at maximum<br />

light output and 0.03 at minimum light output for primary<br />

lamp application.<br />

2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7<br />

or less throughout the dimming range in accordance with<br />

lamp manufacturer recommendations.<br />

2.9 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 10% when operated at nominal line voltage<br />

with primary lamp.<br />

2.10 Ballast shall have a Class A sound rating.<br />

2.11 Ballast shall have a minimum starting temperature of 10C<br />

(50F) for primary lamp.<br />

2.12 Ballast shall provide Lamp EOL Protection Circuit for all<br />

T5, T5/HO, CFL lamps, and T8 lamps operating on 4-lamp<br />

ballast.<br />

2.13 Ballast shall control lamp light output from 100% - 3% relative<br />

light output for T8 and CFL lamps and 100% - 1%<br />

relative light output for T5/HO lamps.<br />

2.14 Ballast shall ignite the lamps at any light output setting<br />

without first going to another output setting.<br />

2.15 Ballast shall tolerate sustained open circuit and short circuit<br />

output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class<br />

P and Type 1 Outdoor; and Canadian Standards Association<br />

(CSA) certified where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to ISO<br />

9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of manufacture<br />

against defects in material or workmanship, including<br />

replacement, for operation at a maximum case temperature<br />

of 70C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be controlled by a Class 1 or Class 2 low voltage<br />

0-10VDC controller.<br />

4.5 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-17


BALLAST SPECIFICATION<br />

SECTION II – Controllable Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for Controllable Light Output <strong>Electronic</strong> Fluorescent<br />

Mark 10 Powerline<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be available in a plastic/metal can or all metal<br />

can construction to meet all plenum requirements.<br />

1.3 Ballast shall be provided with poke-in wire trap connectors<br />

or integral leads color coded per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Programmed Start.<br />

2.2 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.3 Ballast shall operate from 60 Hz input source of 120V, 277V<br />

or 347V as applicable with sustained variations of +/- 10%<br />

(voltage and frequency) with no damage to the ballast.<br />

2.4 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz to avoid interference<br />

with infrared devices and eliminate visible flicker.<br />

2.5 Ballast shall have a Power Factor greater than 0.98 at full<br />

light output and greater than 0.90 throughout the dimming<br />

range for primary lamp.<br />

2.6 Ballast shall have a minimum ballast factor of 1.00 at maximum<br />

light output and 0.05 at minimum light output for primary<br />

lamp application.<br />

2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7<br />

or less throughout the dimming range in accordance with<br />

lamp manufacturer recommendations.<br />

2.8 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 10% at maximum light output when<br />

operated at nominal line voltage with primary lamp. Total<br />

Harmonic Current (THC) at minimum light output shall not<br />

exceed THC at maximum light output.<br />

2.9 Ballast shall have a Class A sound rating.<br />

2.10 Ballast shall have a minimum starting temperature of 10C<br />

(50F) for primary lamp.<br />

2.11 Ballast shall provide Lamp EOL Protection Circuit for all<br />

T5, T5/HO, and CFL lamps.<br />

2.12 Ballast shall control lamp light output from 100% - 5% relative<br />

light output for T8 and CFL lamps and 100% - 1%<br />

relative light output for T5/HO lamps.<br />

2.13 Ballast shall ignite the lamps at any light output setting<br />

without first going to another output setting.<br />

2.14 Ballast shall tolerate sustained open circuit and short circuit<br />

output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class<br />

P and Type 1 Outdoor; and Canadian Standards Association<br />

(CSA) certified where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to ISO<br />

9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of manufacture<br />

against defects in material or workmanship, including<br />

replacement, for operation at a maximum case temperature<br />

of 70C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be controlled by a compatible Mark 10<br />

Powerline two-wire dimmer.<br />

4.5 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

REFERENCE<br />

MATERIALS<br />

8-18<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


BALLAST SPECIFICATION<br />

SECTION II – Controllable Light Output <strong>Electronic</strong> (Fluorescent)<br />

Ballast Specification for Controllable Light Output <strong>Electronic</strong> Fluorescent<br />

ROVR<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Ballast shall be physically interchangeable with standard<br />

electromagnetic or standard electronic ballasts, where<br />

applicable.<br />

1.2 Ballast shall be available in a plastic/metal can or all metal<br />

can construction to meet all plenum requirements.<br />

1.3 Ballast shall be provided with poke-in wire trap connectors<br />

or integral leads color coded per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Ballast shall be Programmed Start.<br />

2.2 Ballast shall be provided with integral protection circuitry to<br />

withstand connection of low voltage control leads to mains<br />

power supply. In this event, ballast shall default to maximum<br />

light output.<br />

2.3 Ballast shall contain auto restart circuitry in order to restart<br />

lamps without resetting power.<br />

2.4 Ballast shall operate from 50/60 Hz input source of 120V or<br />

277V with sustained variations of +/- 10% (voltage and frequency)<br />

with no damage to the ballast. IntelliVolt models<br />

shall operate from 50/60 Hz input source of 120V through<br />

277V with sustained variations of +/- 10% (voltage and frequency)<br />

with no damage to the ballast.<br />

2.5 Ballast shall be high frequency electronic type and operate<br />

lamps at a frequency above 42 kHz to avoid interference<br />

with infrared devices and eliminate visible flicker.<br />

2.6 Ballast shall have a Power Factor greater than 0.98 at full<br />

light output and greater than 0.90 throughout the dimming<br />

range for primary lamp.<br />

2.7 Ballast shall have a minimum ballast factor of 1.00 at maximum<br />

light output and 0.03 at minimum light output for primary<br />

lamp application.<br />

2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7<br />

or less throughout the dimming range in accordance with<br />

lamp manufacturer recommendations.<br />

2.9 Ballast input current shall have Total Harmonic Distortion<br />

(THD) of less than 10% when operated at nominal line voltage<br />

with primary lamp.<br />

2.10 Ballast shall have a Class A sound rating.<br />

2.11 Ballast shall have a minimum starting temperature of 10C<br />

(50F) for primary lamp.<br />

2.12 Ballast shall provide Lamp EOL Protection Circuit for all<br />

T5, T5/HO, CFL lamps, and T8 lamps operating on 4-lamp<br />

ballast.<br />

2.13 Ballast shall control lamp light output from 100% - 3% relative<br />

light output for T8 and CFL lamps and 100% - 1%<br />

relative light output for T5/HO lamps.<br />

2.14 Ballast shall ignite the lamps at any light output setting<br />

without first going to another output setting.<br />

2.15 Ballast shall tolerate sustained open circuit and short circuit<br />

output conditions without damage.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class<br />

P and Type 1 Outdoor; and Canadian Standards Association<br />

(CSA) certified where applicable.<br />

3.3 Ballast shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />

3.5 Ballast shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Ballast shall be manufactured in a factory certified to ISO<br />

9002 Quality System Standards.<br />

4.2 Ballast shall carry a five-year warranty from date of manufacture<br />

against defects in material or workmanship, including<br />

replacement, for operation at a maximum case temperature<br />

of 70C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Ballast shall be controlled by a Class 1 or Class 2 low voltage<br />

DALI controller.<br />

4.5 Ballast shall be <strong>Advance</strong> part # _____________<br />

or approved equal.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-19


BALLAST SPECIFICATION<br />

SECTION III – HID<br />

Ballast Specification for HID <strong>Ballasts</strong><br />

HID<br />

INCLUDING: Metal Halide, High Pressure Sodium, Low Pressure<br />

Sodium & Mercury Vapor<br />

Performance Requirements:<br />

1. <strong>Ballasts</strong> shall be designed in accordance with all applicable<br />

ANSI specifications including ANSI C82.4.<br />

2. The Core & Coil ballast shall be designed with class “H”<br />

(180°C) or higher insulation system and vacuum-pressure<br />

impregnated with a silica-filled polyester resin.<br />

3. All coils shall be precision wound.<br />

4. Core & Coil ballasts shall be designed to operate for 60,000<br />

hours of continuous operation at their maximum rated temperature.<br />

5. Core & Coil ballasts and starter combinations shall be<br />

designed to provide a reliable lamp starting down to -40°C<br />

for High Pressure Sodium and -30°C for Metal Halide at<br />

nominal line voltage of plus or minus 10%.<br />

6. All HID ballast shall have a nominal ballast factor of 1.0<br />

7. All HID ballasts shall contain no exposed live parts.<br />

Regulatory and Other Requirements<br />

1. Ballast shall be manufactured in an ISO 9002 and ISO 14001<br />

Certified Facility.<br />

2. Manufacturer shall provide written warranty against defects<br />

in workmanship, including replacement, for two years from<br />

date of manufacture.<br />

3. Manufacturer shall have been manufacturing HID ballasts for<br />

at least ten years.<br />

4. All HID ballasts shall be UL component recognized.<br />

5. All HID ballasts shall be CSA certified.<br />

6. Ballast must be <strong>Advance</strong> Transformer (or approved equal).<br />

CAPACITORS for HID<br />

1. All capacitors will be provided with a self-contained internal<br />

bleeder resistor where required according to UL1029.<br />

2. Oil-filled capacitors will be housed in aluminum or corrosionresistant<br />

steel cans and contain .25” quick disconnect terminals.<br />

3. Oil filled capacitors shall have a 90°C max case temperature<br />

rating.<br />

4. Dry film capacitors shall have a 105°C max. case temperature<br />

rating.<br />

5. All dry film capacitors shall be manufactured by the ballast<br />

manufacturer.<br />

6. All capacitors rated 400V or less shall be dry film type.<br />

7. All dry film capacitors shall have no exposed live parts.<br />

IGNITORS for HID<br />

1. All ignitors will be polyester resin-filled with either a plastic<br />

or aluminum external housing.<br />

2. The ignitor shall be so designed to provide six months of<br />

lamp open circuit operation without failure.<br />

3. All ignitors shall have a case rating temperature of 105°C.<br />

4. All ignitors shall be designed to withstand 10,000 hours of<br />

continuous pulsing.<br />

5. All ignitors shall have no exposed live parts.<br />

HID RETROFIT KITS<br />

1. All HID kits shall be precision wound to insure proper insulation.<br />

2. All HID kits shall be pre-wired with ignitors.<br />

3. HID core and coil shall be interchangeable with prior ballast<br />

or include mounting bracket to adapt ballast to intended fixture.<br />

4. All HID kits shall be supplied with pre-insulated input voltage<br />

leads.<br />

5. All HID kits are to be UL and CSA recognized following the<br />

guidelines found in UL 1029 and CAN/CSA-22.2 No. 74-92<br />

(part 2 and 3).<br />

8. The core & coil shall be designed with class “H” (180°C) or<br />

higher insulation system and vacuum-pressure impregnated<br />

with a silica-filled polyester resin.<br />

9. All capacitors rated 400V or less shall be dry film type rated<br />

105°C.<br />

10. There are to be no exposed live parts on the core & coil,<br />

ignitor, or dry capacitor.<br />

11. Must meet all ANSI Specifications for the specified lamp.<br />

12. Kit must include installation instructions and a 1-800# for<br />

field assistance.<br />

13. Ballast must be <strong>Advance</strong> Part # __________________<br />

(or approved equal).<br />

REFERENCE<br />

MATERIALS<br />

8-20<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


BALLAST SPECIFICATION<br />

SECTION IV – <strong>Electronic</strong> HID (Metal Halide)<br />

Ballast Specification for <strong>Electronic</strong> Metal Halide<br />

e-Vision ® <strong>Electronic</strong> Ballast Specifications<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.0 The electronic ballast shall be furnished with integral, color-coded leads.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.0 The electronic ballast shall be IntelliVolt ® and operate from a nominal<br />

line voltage range of 120-277 volts, +/-10%, 50/60 Hz.<br />

2.1 The electronic ballast input current shall have Total Harmonic<br />

Distortion (THD) of less than 15%.<br />

2.2 The electronic ballast shall have a Power Factor greater than 90%.<br />

2.3 The electronic ballast shall have a lamp end-of-life detection and<br />

shutdown circuit.<br />

2.4 The electronic ballast shall be Sound Rated A.<br />

2.5 The electronic ballast output frequency to the lamps shall be less<br />

than 200 Hz to prevent acoustic resonance inside the lamp arc tube<br />

and to minimize visible flicker.<br />

2.6 The electronic ballast shall provide a “Lamp Current Crest Factor” of<br />

less than 1.5.<br />

2.7 The electronic ballast shall be thermally protected to shut off when<br />

operating temperatures reach unacceptable levels.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.0 The electronic ballast shall meet the requirements of the Federal<br />

Communications Commission rules and regulations, Title 47 CFR<br />

part 18, for Non-Consumer equipment.<br />

3.1 The electronic ballast shall be Underwriters Laboratories (UL) Listed<br />

(Class P) and CSA Certified where applicable.<br />

<strong>Section</strong> IV - Other<br />

4.0 The electronic ballast shall not contain Polychlorinated Biphenyl (PCB’s).<br />

4.1 The electronic ballast shall carry a three-year warranty from the date<br />

of manufacture for operation at a case temperature of 85ÞC or less.<br />

4.2 The manufacturer shall have a twenty-five year history of producing<br />

HID lamp ballasts for the North American market.<br />

4.3 The electronic ballast shall be produced in a factory certified to ISO<br />

9002 Quality System Standards<br />

DynaVision <strong>Electronic</strong> Ballast Specifications<br />

<strong>Section</strong> I – Physical Characteristics<br />

1.1 The electronic ballast shall be fully enclosed in an aluminum housing<br />

painted white.<br />

1.2 The aluminum housing shall include a divided wiring compartment<br />

to separate the power leads from the control leads. All leads to be<br />

color-coded.<br />

<strong>Section</strong> II – Performance Requirements<br />

2.1 The electronic ballast shall be multivoltage capable and operate from<br />

a line voltage range of 180 – 305 volts, 50/60 Hz.<br />

2.2 The electronic ballast shall incorporate a microprocessor controller<br />

to provide for optimum starting and operation of the HID lamp.<br />

2.3 The electronic ballast input current shall have Total Harmonic<br />

Distortion (THD) of less than 15% when operated at nominal line<br />

voltage (200V, 208V, 230V, 240V, 277V).<br />

2.4 The ballast shall incorporate a 0-10V dimming interface and<br />

control the dimming function such that the HID lamp is allowed to<br />

warm up for fifteen minutes at full power before the lamp will be<br />

allowed to dim, regardless of the level of the 0-10V signal.<br />

10V applied to the dimming control leads, shall result in full<br />

light output. 0V applied, or shorting the control leads together, shall<br />

result in dimming to 50% of nominal lamp power.<br />

2.5 The ballast shall include a 120V/250W auxiliary output for stand-by<br />

incandescent lighting that shall include an integral control to turn the<br />

auxiliary lamp on and off. The integral control shall include a timedelay<br />

feature to keep the auxiliary lamp on until the HID lamp reaches<br />

50% power.<br />

2.6 The electronic ballast shall have a Power Factor greater than 90%.<br />

2.7 The electronic ballast shall have a lamp end-of-life detection and<br />

shutdown circuit.<br />

2.8 The electronic ballast shall be Sound Rated A.<br />

2.9 The electronic ballast output frequency to the lamps shall be higher<br />

than 100 kHz to prevent acoustic resonance inside the lamp arc tube<br />

and to minimize visible flicker.<br />

2.10 The electronic ballast shall be thermally protected to shut off when<br />

operating temperatures reach unacceptable levels.<br />

<strong>Section</strong> III – Regulatory Requirements<br />

3.1 The electronic ballast shall meet the requirements of the Federal<br />

Communications Commission rules and regulations, Title 47 CFR<br />

part 18, for Non-Consumer equipment.<br />

3.2 The electronic ballast shall be Underwriters Laboratories (UL) Listed<br />

and CSA Certified where applicable.<br />

<strong>Section</strong> VI – Other<br />

4.1 The electronic ballast shall not contain Polychlorinated Biphenyl (PCB’s).<br />

4.2 The electronic ballast shall carry a three-year warranty from the date<br />

of manufacture for operation at an ambient temperature of 55° C or<br />

less and when operated as a stand alone product (i.e.remotely from<br />

a lighting fixture housing). When operated within a lighting fixture<br />

housing, the same three-year warranty shall apply for a maximum<br />

ballast case hot spot temperature of 76° C or less.<br />

4.3 The manufacturer shall have a twenty-five year history of producing<br />

HID lamp ballasts for the North American market.<br />

4.4 The electronic ballast shall be produced in a factory certified to<br />

ISO 9002 Quality System Standards.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-21


BALLAST SPECIFICATION<br />

SECTION V – Xitanium LED Drivers<br />

Ballast Specification for Xitanium LED Drivers<br />

Xitanium<br />

<strong>Section</strong> I - Physical Characteristics<br />

1.1 Driver shall be available in a plastic/metal can or all metal<br />

can construction to meet all plenum requirements.<br />

1.2 Driver shall be provided with poke-in wire trap connectors<br />

or integral leads color coded per ANSI C82.11.<br />

<strong>Section</strong> II - Performance Requirements<br />

2.1 Driver shall operate from 60 Hz input source of 120V with<br />

sustained variations of +/- 10% (voltage and frequency)<br />

with no damage to the Driver.<br />

2.2 Driver output shall be regulated to +/- 5% across published<br />

load range.<br />

2.3 Driver shall operate LEDs at a frequency of 60 Hz.<br />

2.4 Driver shall have a Power Factor greater than 0.90 for<br />

primary application.<br />

2.5 Driver input current shall have Total Harmonic Distortion<br />

(THD) of less than 20%.<br />

2.6 Driver shall have a Class A sound rating.<br />

2.7 Driver shall have a minimum operating temperature of -40C<br />

(-40F).<br />

2.8 Driver shall tolerate sustained open circuit and short circuit<br />

output conditions without damage and without need for<br />

external fuses or trip devices.<br />

<strong>Section</strong> III - Regulatory Requirements<br />

3.1 Driver shall not contain any Polychlorinated Biphenyl<br />

(PCB).<br />

3.2 Driver shall be Underwriters Laboratories (UL) listed, Class<br />

2 Outdoor; and Canadian Standards Association (CSA) certified<br />

where applicable.<br />

3.3 Driver shall comply with ANSI C62.41 Category A for<br />

Transient protection.<br />

3.4 Driver shall comply with the requirements of the Federal<br />

Communications Commission (FCC) rules and regulations,<br />

Title 47 CFR part 15, Non-Consumer (Class A) for EMI/RFI<br />

(conducted and radiated).<br />

<strong>Section</strong> IV - Other<br />

4.1 Driver shall be manufactured in a factory certified to ISO<br />

9002 Quality System Standards.<br />

4.2 Driver shall carry a five-year warranty from date of manufacture<br />

against defects in material or workmanship, including<br />

replacement, for operation at a maximum case temperature<br />

of 90C.<br />

4.3 Manufacturer shall have a fifteen year history of producing<br />

electronic ballasts for the North American market.<br />

4.4 Dimmable drivers shall be controlled by a Class 2 low voltage<br />

0-10VDC controller.<br />

4.5 Driver shall be <strong>Advance</strong> Part # __________________<br />

or approved equal.<br />

REFERENCE<br />

MATERIALS<br />

8-22<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDEX<br />

Contents<br />

Ballast Catalog Number to Page Number<br />

Fluorescent ................................................................... 8-24 to 8-32<br />

HID................................................................................ 8-33 to 8-34<br />

Discontinued <strong>Ballasts</strong> - Replacements<br />

Electromagnetic Fluorescent....................................................... 8-35 to 8-36<br />

Fluorescent ............................................................................................. 8-37<br />

HID ............................................................................................. 8-38 to 8-41<br />

Lamp Index<br />

HID ............................................................................................ 8-42<br />

CFL ............................................................................................ 8-43<br />

Corporate Offices<br />

(800) 322-2086<br />

Customer Support/Technical Service<br />

(800) 372-3331 • (+) 1 847 390-5000 (International)<br />

Visit our web site at www.advancetransformer.com<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-23


INDEX – FLUORESCENT BALLASTS<br />

CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />

REFERENCE<br />

MATERIALS<br />

Catalog<br />

Number<br />

See<br />

Page<br />

No. Black White Blue Red Yellow<br />

Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />

Tolerance: +2", -1"<br />

A-175-S 6-16 10 71 47 10 40<br />

ADM-2E40-S-TP 6-16 41 41 23 23 10 58<br />

ADM-2E75-S-TP 6-16 70 70 46 46 10 58<br />

ASB-0412-12-BL-TP 3-40 18 18 33 33 51 1 12 ✓<br />

ASB-0620-24-BL-TP 3-40 24 24 75 46 75 46 46 1 12 ✓<br />

ASB-1224-24-BL-TP 3-40 24 24 74 32 70 52 78 1 14 ✓<br />

ASB-1240-46-BL-TP 3-40 24 24 50 80 70 50 50 50 50 1 21 ✓<br />

ASB-2040-24-BL-TP 3-40 24 24 80 80 72 54 72 1 21 ✓<br />

ASB-2432-34-BL-TP 3-40 24 24 72 72 72 72 72 1 18 ✓<br />

ASB-2448-46-BL-TP 3-40 24 24 50 50 70 50 50 50 50 1 21 ✓<br />

DIM-140-H-TP 3-12 35 35 20 20 20 10 37<br />

DIM-240-H-TP 3-12 18 34 34 20 20 34 18 6 38 ✓<br />

G-140-TP 3-7, 3-9, 3-10, 3-11 22 35 23 22 10 34<br />

G-1S32-TP 3-5, 3-6 18 35 23 18 10 35<br />

G-2E75-S-TP 3-22, 3-23 12 12 12 12 12 6 47<br />

G-2S110-TP 3-16, 3-17 22 22 46 46 70 6 70<br />

G-2S32-TP 3-5, 3-6 20 20 24 24 38 10 37<br />

G-2S40-TP 3-7, 3-9, 3-10, 3-11 12 12 12 12 12 10 34<br />

GCN-1S32 1-48, 1-54, 1-58 25 25 31 37 10 24<br />

GCN-2P32 1-48, 49, 54, 55, 58, 59 25 25 31 27 10 24<br />

GCN-2S32 1-49, 1-55, 1-59 22 22 26 26 36 10 24<br />

GCN-2TTP40-SC 1-35 25 25 30 30 20 28<br />

GCN-3S32 1-46, 1-50, 1-56, 1-60 22 22 26 36 26 36 10 28<br />

GEL2P32LW-RH-TP 1-45, 49, 54, 55, 59 25 25 31 37 10 24<br />

GEL-2P32-SC 1-45, 48, 49, 54, 55,58, 59 25 25 31 37 20 32<br />

GEL-2P59 1-64 25 25 31 37 10 28<br />

GEL-2S32-RH-TP 1-55, 1-59 22 22 26 26 36 10 24<br />

GEL-2S40-RH-TP 1-66, 1-67 22 22 26 26 36 10 24<br />

GEL-3P32-RH-TP 1-50, 1-56, 1-60, 1-63 25 25 31 37 10 28<br />

GEL-4P32-LW 1-47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 10 28<br />

GEL-4P32-RH-TP 1-47, 51, 57, 61, 63 25 25 31 31 39 10 28<br />

GK-132-TP 1-58 18 35 23 18 10 35<br />

GK-2S32-TP 1-59 22 22 26 26 36 10 38<br />

H-1B13-TP-BLS 3-34 7 7 7 35 32<br />

H-1B13-TP-W 3-34 15 15 15 36 36 ✓<br />

H-1B9-TP-BLS 3-33 7 7 7 35 28<br />

H-1B9-TP-W 3-33 15 15 15 36 29 ✓<br />

H-1Q18-TP-BLS 3-35 7 7 7 20 46<br />

H-1Q18-TP-W 3-35 15 15 15 20 46 ✓<br />

H-1Q22-TP-BLS 3-35 7 7 7 27 35<br />

H-1Q22-TP-W 3-35 15 15 15 24 31<br />

H-1Q26-TP-BLS 3-35, 3-36 7 7 7 20 46<br />

H-1Q26-TP-W 3-35, 3-36 15 15 15 20 46 ✓<br />

H-1Q28-TP-BLS 3-35 7 7 7 27 38<br />

H-1Q28-TP-W 3-35 15 15 15 24 34<br />

H-2B13-TP-BLS 3-34 7 7 7 20 36<br />

H-2B13-TP-W 3-34 15 15 15 20 36<br />

H-2B9-TP-BLS 3-33 7 7 7 20 32<br />

H-2B9-TP-W 3-33 15 15 15 20 32<br />

H-2Q18-TP-BLS 3-35 7 7 7 10 40<br />

H-2Q18-TP-W 3-35 15 15 15 10 40<br />

H-2Q26-TP-BLS 3-35 7 7 7 10 40<br />

H-2Q26-TP-W 3-35 15 15 15 10 40<br />

HCN-2S54-90C 1-34, 36, 37, 42, 43 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12 ✓<br />

HCN-4S54-90C-2LS-G 1-34, 36, 37, 43 32 32 54 51 60 42 60 42 6 18 ✓<br />

HF-B 136 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

HF-B 158 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

HF-B 236 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HF-B 258 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HF-P 1 14-35 TL5 HE 6-11 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

HF-P 118 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />

*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />

** Also includes 36" violet & grey control leads.<br />

Blue/<br />

White<br />

Black/<br />

White<br />

Yellow/<br />

Blue<br />

Brown<br />

Red/<br />

White<br />

Orange Orange/<br />

Black<br />

Units<br />

Std.<br />

Ctn.<br />

Shipping Data<br />

Weight<br />

Std.<br />

Ctn. (lbs)<br />

Avail<br />

IC*<br />

Ctn.<br />

8-24<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDEX – FLUORESCENT BALLASTS<br />

CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />

Catalog<br />

Number<br />

See<br />

Page<br />

No. Black White Blue Red Yellow<br />

Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />

Tolerance: +2", -1"<br />

Blue/<br />

White<br />

Black/<br />

White<br />

Yellow/<br />

Blue<br />

Brown<br />

Red/<br />

White<br />

Orange Orange/<br />

Black<br />

Units<br />

Std.<br />

Ctn.<br />

Shipping Data<br />

Weight<br />

Std.<br />

Ctn. (lbs)<br />

HF-P 1 24-39 TL5 HO 6-11 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

HF-P 136 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

HF-P 136 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

HF-P 140 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

HF-P 1 54 TL5 HO 6-11 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

HF-P 155 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

HF-P 158 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 6<br />

HF-P 2 14-35 TL5 HE 6-11 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HF-P 218 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HF-P 2 24-39 TL5 HO 6-11 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HF-P 236 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HF-P 236 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HF-P 240 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HF-P 2 54 TL5 HO 6-11 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HF-P 255 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HF-P 258 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 7<br />

HM-140-TP 6-14 22 35 23 22 10 34<br />

HM-1P20-TP 3-27, 3-28 8 10 10 8 10 32 ✓<br />

HM-1P30-TP 3-8 18 26 17 18 10 34 ✓<br />

HM-2SP20-TP 3-27, 3-28 10 10 13 13 16 10 34 ✓<br />

ICF-1D38-H1-LD 1-39, 1-42 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-1H120-M4-BS 1-33 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 21<br />

ICF-1H120-M4-LD 1-33 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 26<br />

ICF-2S13-H1-LD 1-27, 1-29, 1-38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S13-H1-LD-K 1-27, 1-29, 1-38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8 ✓<br />

ICF-2S13-H1-LD-QS 1-27, 1-29 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S13-M1-BS 1-27, 1-29, 1-38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

ICF-2S13-M1-BS-QS 1-27, 1-29 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

ICF-2S13-M1-LS 1-27, 1-29, 1-38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S13-M1-LS-QS 1-27, 1-29 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S18-H1-LD 1-27, 1-30, 1-38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S18-H1-LD-K 1-27, 1-30, 1-38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8 ✓<br />

ICF-2S18-H1-LD-QS 1-27, 1-30 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S18-M1-BS 1-27, 1-30, 1-38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

ICF-2S18-M1-BS-QS 1-27, 1-30 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

ICF-2S18-M1-LS 1-27, 1-30, 1-38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S18-M1-LS-QS 1-27, 1-30 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S26-H1-LD 1-28, 31, 32, 34, 38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S26-H1-LD-K 1-28, 31, 32, 34, 38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8 ✓<br />

ICF-2S26-H1-LD-QS 1-28, 31, 32 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S26-M1-BS 1-28, 31, 32, 34, 38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

ICF-2S26-M1-BS-QS 1-28, 1-31, 1-32 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

ICF-2S26-M1-LS 1-28, 31, 32, 34, 38 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S26-M1-LS-QS 1-28, 1-31, 1-32 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

ICF-2S42-M2-BS 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 13<br />

ICF-2S42-M2-LD 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

ICF-2S42-M2-LD-K 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16 ✓<br />

ICF-2S42-M2-LS 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

ICF-2S42-90C-M2-BS 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 13<br />

ICF-2S42-90C-M2-LD 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

ICF-2S42-90C-M2-LS 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

ICF-2S70-M4-BS 1-32 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 21<br />

ICF-2S70-M4-LD 1-32 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 26<br />

ICN-132-MC 1-41, 1-44, 1-54, 1-58 25 31 37 25 20 15 ✓<br />

ICN-1P32-LW-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 28 ✓<br />

ICN-1P32-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 28 ✓<br />

ICN-1S80 1-43, 6-6 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

ICN-2M32-MC 1-41, 45, 49, 55, 59 25 25 31 37 20 15 ✓<br />

ICN-2P32-LW-SC 1-44, 45, 48, 49, 54, 55, 59, 62 25 25 31 37 20 28 ✓<br />

ICN-2P32-SC 1-44, 45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 28 ✓<br />

ICN-2S24 1-34, 1-35, 1-42, 1-43 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12 ✓<br />

*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />

*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />

** Also includes 36" violet & grey control leads.<br />

Avail<br />

IC*<br />

Ctn.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-25


INDEX – FLUORESCENT BALLASTS<br />

CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />

REFERENCE<br />

MATERIALS<br />

Catalog<br />

Number<br />

See<br />

Page<br />

No. Black White Blue Red Yellow<br />

Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />

Tolerance: +2", -1"<br />

Blue/<br />

White<br />

Black/<br />

White<br />

Yellow/<br />

Blue<br />

Brown<br />

Red/<br />

White<br />

Orange Orange/<br />

Black<br />

Units<br />

Std.<br />

Ctn.<br />

Shipping Data<br />

Weight<br />

Std.<br />

Ctn. (lbs)<br />

ICN-2S28 1-41 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12 ✓<br />

ICN-2S39 1-34, 1-35, 1-42, 1-43 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12 ✓<br />

ICN-2S54 1-34, 36, 37, 42, 43, 6-6 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12 ✓<br />

ICN-2S54-90C 1-34, 36, 37, 42, 43, 6-6 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12 ✓<br />

ICN-2S86 1-65 22 22 46 46 70 6 25 ✓<br />

ICN-3P32-LW-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />

ICN-3P32-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />

ICN-3S14-D 1-41 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

ICN-4P32-LW-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 35 20 28 ✓<br />

ICN-4P32-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 35 20 28 ✓<br />

ICN-4S54-90C-2LS 1-34, 36, 37, 43, 6-6 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 18<br />

ICN-4S54-90C-2LS-G 1-34, 36, 37, 43, 6-6 32 32 54 51 60 42 60 42 6 18 ✓<br />

IDA-132-SC 2-21 22 46 26 22 20 15<br />

IDA-154 2-19, 2-20 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

IDA-2S32-SC 2-21 22 22 26 26 46 20 21<br />

IDA-2S54 2-19, 2-20 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

IDA-3S32-G 2-21 22 22 28 54 28 54 6 18<br />

IDA-4S32 2-21 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

IDL-2S26-M5-BS 2-18 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

IDL-2S26-M5-LD 2-18 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

IDL-2T42-M5-BS 2-18 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

IDL-2T42-M5-LD 2-18 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

IEZ-124-D 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

IEZ-2S24-D 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

IIC-132-SC 1-44, 1-48, 1-54, 1-58 22 46 26 22 20 20 ✓<br />

IIC-2S32-SC 1-45, 1-49, 1-55, 1-59 22 22 26 26 46 20 20 ✓<br />

IIC-3S32-SC 1-46, 1-50, 1-56, 1-60 22 22 26 46 26 46 20 30 ✓<br />

IOP-1P32-HL-SC 1-44, 48, 52, 53, 54, 58 25 31 37 25 20 28 ✓<br />

IOP-1P32-LW-SC 1-44, 48, 52, 53, 54, 58 25 31 37 25 20 28 ✓<br />

IOP-1P32-SC 1-44, 48, 52, 53, 54, 58 25 31 37 25 20 28 ✓<br />

IOP-1S32-LW-SC 1-44, 48, 52, 53, 54, 58 36 36 26 25 20 20<br />

IOP-1S32-SC 1-44, 48, 52, 53, 54, 58 36 36 26 25 20 20<br />

IOP-2P32-HL-SC 1-44, 45, 48, 49, 52, 53, 54, 55, 58, 59, 62 25 25 31 37 20 28 ✓<br />

IOP-2P32-LW-SC 1-44, 45, 48, 49, 52, 53, 54, 55, 58, 59, 62 25 25 31 37 20 28 ✓<br />

IOP-2P32-SC 1-44, 45, 48, 49, 52, 53, 54, 55, 58, 59, 62 25 25 31 37 20 28 ✓<br />

IOP-2P59-SC 1-64 22 22 46 70 20 20 ✓<br />

IOP-2S28-115-SC-SD 2-3 (2) 22 22 26 26 36 20 20<br />

IOP-2S28-95-SC-SD 2-3 (2) 22 22 26 26 36 20 20<br />

IOP-2S32-LW-SC 1-44, 45, 48, 49, 52, 53, 54, 55, 58, 59, 62 25 25 31 37 20 20 ✓<br />

IOP-2S32-SC 1-44, 45, 48, 49, 52, 53, 54, 55, 58, 59, 62 25 25 31 37 20 20 ✓<br />

IOP-3P32-HL-90C-SC 1-45, 46, 49, 50, 52, 53, 55, 56, 59, 60, 62 25 25 31 37 20 32 ✓<br />

IOP-3P32-LW-SC 1-45, 46, 49, 50, 52, 53, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />

IOP-3P32-SC 1-45, 46, 49, 50, 52, 53, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />

IOP-3S32-LW-SC 1-46, 50, 52, 53, 56, 60 25 25 31 37 20 28 ✓<br />

IOP-3S32-SC 1-46, 50, 52, 53, 56, 60 25 25 31 37 20 28 ✓<br />

IOP-4P32-HL-90C-G 1-46, 47, 50, 51, 52, 53, 56, 57, 60, 61, 63 25 25 31 31 39 6 18 ✓<br />

IOP-4P32-LW-SC 1-46, 47, 50, 51, 52, 53, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />

IOP-4P32-SC 1-46, 47, 50, 51, 52, 53, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />

IOP-4S32-LW-SC 1-47, 51, 52, 53, 57, 61 25 25 31 31 39 20 28 ✓<br />

IOP-4S32-SC 1-47, 51, 52, 53, 57, 61 25 25 31 31 39 20 28 ✓<br />

IUV-2S18-H1-LD 6-5 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

IUV-2S36-M2-LD 6-5 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

IUV-2S60-M4-BS 6-5 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 21<br />

IUV-2S60-M4-LD 6-5 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 26<br />

IZT-132-SC ** 2-15, 2-16 22 46 26 22 20 15 ✓<br />

IZT-2S26-M5-BS 2-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

IZT-2S26-M5-LD 2-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

IZT-2S32-SC ** 2-15, 2-16 22 22 26 26 46 20 21 ✓<br />

IZT-2T42-M5-BS 2-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

IZT-2T42-M5-LD 2-12 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

IZT-2TTS40-SC ** 2-13 12 12 24 24 24 20 21<br />

*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />

*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />

** Also includes 36" violet & grey control leads.<br />

Avail<br />

IC*<br />

Ctn.<br />

8-26<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDEX – FLUORESCENT BALLASTS<br />

CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />

Catalog<br />

Number<br />

See<br />

Page<br />

No. Black White Blue Red Yellow<br />

Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />

Tolerance: +2", -1"<br />

Blue/<br />

White<br />

Black/<br />

White<br />

Yellow/<br />

Blue<br />

Brown<br />

Red/<br />

White<br />

Orange Orange/<br />

Black<br />

Units<br />

Std.<br />

Ctn.<br />

Shipping Data<br />

Weight<br />

Std.<br />

Ctn. (lbs)<br />

IZT-3S32-SC ** 2-15, 2-16 22 22 26 46 26 46 20 21 ✓<br />

IZT-4S32 2-15, 2-16 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

L-120F 3-25, 3-26 (2) 10 36 32 ✓<br />

L-140F-TP 3-25, 3-26, 3-29, 3-36 43 27 14 20 42 ✓<br />

L-1B13-TP-BLS 3-34 7 7 35 32<br />

L-1B13-TP-W 3-34 15 15 36 36<br />

L-1B9-TP-BLS 3-33 7 7 35 28<br />

L-1B9-TP-W 3-33 15 15 36 29 ✓<br />

L-1BC13-TP-BLS 3-34 7 7 27 41<br />

L-1BC13-TP-W 3-34 15 15 24 36<br />

L-1Q13-TP-W 3-24, 3-34 15 15 15 20 40 ✓<br />

L-1Q18-TP-BLS 3-35 7 7 7 20 40<br />

L-1Q18-TP-W 3-35 15 15 15 20 40 ✓<br />

L-1Q26-TP-BLS 3-35, 3-36 7 7 7 20 40<br />

L-1Q26-TP-W 3-35, 3-36 15 15 15 20 40 ✓<br />

L-220F 3-25, 3-26 10 12 20 36 ✓<br />

LC-13-TP 3-31 17 14 50 35<br />

LC-14-20-C 3-25, 3-26 14, 17 50 30 ✓<br />

LC-14-20-C-TP 3-29 17 14 50 35<br />

LC-25 3-26 7, 22 50 35 ✓<br />

LC-25-TP 3-32 7 22 50 35 ✓<br />

LC-4-9-C 3-24 (2) 10 50 30 ✓<br />

LC-4-9-C-TP 3-31 10 10 50 30<br />

LO-13-22 3-25, 3-26 (2) 15 72 43<br />

LO-13-22-TP 3-29, 3-31, 3-32 15 15 72 43<br />

LO-1Q22 3-32 (2) 15 72 43<br />

LO-1Q28-TP 3-32 15 15 20 26 ✓<br />

LOS-1Q28 3-32 (2) 15 72 58<br />

LPL-5-9 3-24 (2) 9 135 41<br />

LPL-5-9-TP 3-31 9 9 120 36<br />

LPL-7-9 3-24 (2) 9 150 45<br />

LQ-106F-TP 3-27 10 10 10 10 20 40 ✓<br />

LQ-206F-TP 3-27 10 10 10 10 10 20 40 ✓<br />

LS-113-TP 3-24 15 15 15 20 28 ✓<br />

LSX-113-TP 3-24 15 15 15 15 36 36<br />

LSX-213-TP 3-24 15 15 15 15 36 43 ✓<br />

LX-140-F-TP 3-25, 3-26, 3-29, 3-36 26 26 26 10 26 20 40 ✓<br />

MT-2S110-TP 6-15 18 18 46 46 70 18 6 60<br />

MTM-140-TP 6-14 18 18 35 23 28 10 40<br />

MTM-2S40-TP 6-14 18 18 24 24 36 18 10 40<br />

R-140-TP 3-7, 3-9, 3-10 12 12 12 12 10 36 ✓<br />

R-1BP27-TP 3-37 12 12 12 12 10 36<br />

R-1BP39-TP 3-37 12 12 12 12 10 36 ✓<br />

R-1BP40-TP 3-37 18 28 28 18 10 36 ✓<br />

R-1P32-TP 3-5, 3-6 18 36 23 18 10 37 ✓<br />

R-1P817-TP 3-5, 3-6, 3-37 18 17 17 18 10 36 ✓<br />

R-1P825-TP 3-5, 3-6 18 24 24 18 10 36<br />

R-1P840-TP 3-5 18 44 28 18 10 37<br />

R-1U40-TP 3-11 12 12 12 12 10 36 ✓<br />

R-2BP27-TP 3-37 12 12 24 24 24 10 37<br />

R-2BS39-TP 3-37 12 12 24 24 24 10 37 ✓<br />

R-2BS40-TP 3-37 20 20 24 24 36 10 37 ✓<br />

R-2E60-S-TP 3-23 12 12 12 12 6 49 ✓<br />

R-2E75-S-TP 3-22, 3-23, 6-16 12 12 12 12 6 49 ✓<br />

R-2P32-TP 3-5, 3-6 20 20 24 24 36 10 37 ✓<br />

R-2P817-TP 3-5, 3-6, 3-37 10 10 14 14 26 10 37 ✓<br />

R-2P825-TP 3-5, 3-6 12 12 20 20 32 10 37 ✓<br />

R-2P840-TP 3-5 20 20 28 28 44 10 37 ✓<br />

R-2S110-TP 3-16, 3-17 22 22 46 46 70 6 71 ✓<br />

R-2S34-TP 3-9, 3-10, 3-11 12 12 12 12 12 10 36 ✓<br />

R-2S40-TP 3-7, 9, 10, 11, 6-14 12 12 12 12 12 10 36 ✓<br />

*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />

*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />

** Also includes 36" violet & grey control leads.<br />

Avail<br />

IC*<br />

Ctn.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-27


INDEX – FLUORESCENT BALLASTS<br />

CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />

REFERENCE<br />

MATERIALS<br />

Catalog<br />

Number<br />

See<br />

Page<br />

No. Black White Blue Red Yellow<br />

Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />

Tolerance: +2", -1"<br />

Blue/<br />

White<br />

Black/<br />

White<br />

Yellow/<br />

Blue<br />

Brown<br />

Red/<br />

White<br />

Orange Orange/<br />

Black<br />

Units<br />

Std.<br />

Ctn.<br />

Shipping Data<br />

Weight<br />

Std.<br />

Ctn. (lbs)<br />

R-2SP30-TP 3-8 18 18 17 17 26 10 37 ✓<br />

R-3S34-TP 3-9 20 20 24 36 24 36 10 37 ✓<br />

R-4S40-A-TP-AC 3-9, 3-10 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 1 7 ✓<br />

RC-2E75-S-TP 3-22, 3-23 12 12 12 12 6 49 ✓<br />

RC-2S102-FO 3-39 6.5 6.5 6.5 6.5 6.5 1 17 ✓<br />

RC-2S102-TP 3-18, 3-19 18 18 43 43 19 4 46 ✓<br />

RC-2S110-FO 3-38 6.5 6.5 6.5 6.5 6.5 1 17 ✓<br />

RC-2S200-TP 3-18, 3-19 22 22 44 44 68 4 60 ✓<br />

RC-2S85-FO 3-38 6.5 6.5 6.5 6.5 6.5 1 18 ✓<br />

RC-2S85-TP 3-13, 14, 15, 16, 17 18 18 33 33 51 6 60 ✓<br />

RC-2SP830-TP 3-27 18 18 24 24 36 10 39<br />

RC-4S60-TP 3-13, 3-14, 3-16 24 24 46 46 46 46 46 6 66 ✓<br />

RC-4S85-TP 3-14, 3-15, 3-16, 3-17 24 24 74 32 70 52 78 4 55 ✓<br />

RCF-2S13-H1-LD-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

RCF-2S13-M1-BS-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

RCF-2S13-M1-LS-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

RCF-2S18-H1-LD-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

RCF-2S18-M1-BS-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

RCF-2S18-M1-LS-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

RCF-2S26-H1-LD-QS 1-28, 1-31, 1-32, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

RCF-2S26-M1-BS-QS 1-28, 1-31, 1-32, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

RCF-2S26-M1-LS-QS 1-28, 1-31, 1-32, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

RCN-1S32-SC 1-44, 1-48, 1-54, 1-58 25 36 26 25 20 28 ✓<br />

RCN-1TTP40-SC 1-35 25 30 30 25 20 28 ✓<br />

RCN-2P59 1-64 22 22 46 70 10 28 ✓<br />

RCN-2S32-SC 1-45, 1-49, 1-55, 1-59 25 25 26 26 36 20 28 ✓<br />

RCN-2TTP40-SC 1-35 25 25 30 30 20 28 ✓<br />

RCN-3S32-SC 1-46, 1-50, 1-56, 1-60 25 25 46 36 36 36 20 28 ✓<br />

RCN-3TTP40-SC 1-35 25 25 30 30 20 28 ✓<br />

RCN-4S32-SC 1-47, 1-51, 1-57, 1-61 25 25 36 36 46 36 46 20 28 ✓<br />

REB-2P32-SC 1-44, 45, 48, 49, 58, 59, 6-4 25 25 31 37 20 15<br />

REB-2S18-M1-BS-DIM 2-5, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

REB-2S18-M1-LS-DIM 2-5, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

REB-2S26-M1-BS-DIM 2-5, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 6.4<br />

REB-2S26-M1-LS-DIM 2-5, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 8<br />

REB-4P32-SC 1-46, 47, 50, 51, 60, 61, 6-4 25 25 31 31 39 20 20<br />

REL-1P32-HL-SC 1-44, 48, 54, 58, 62 25 31 37 25 20 32 ✓<br />

REL-1P32-LW-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 32 ✓<br />

REL-1P32-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 24 ✓<br />

REL-1S40-SC 1-66, 1-67 22 36 26 22 20 32 ✓<br />

REL-1TTS39 1-34 12 24 24 12 10 25 ✓<br />

REL-1TTS40 1-35 12 24 24 12 10 25 ✓<br />

REL-1TTS50 1-36, 1-37 12 24 24 12 10 25 ✓<br />

REL-2P17-RH-TP 1-44, 1-45 22 22 24 24 10 25 ✓<br />

REL-2P30-G 6-5 22 22 24 24 10 25<br />

REL-2P32-HL-SC 1-45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />

REL-2P32-LW-SC 1-45, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />

REL-2P32-SC 1-45, 48, 49, 54, 55, 58, 59, 6-6 25 25 31 37 20 24 ✓<br />

REL-2P59-SC 1-64 22 22 46 70 20 20 ✓<br />

REL-2P59-S-RH-TP 1-64 22 22 46 70 10 28 ✓<br />

REL-2P60-S 1-68 22 22 46 70 6 27 ✓<br />

REL-2P64-IS 6-5 48 48 48 48 6 27<br />

REL-2S110 1-69 22 22 46 46 70 6 27 ✓<br />

REL-2S40-SC 1-66, 1-67 22 22 26 26 36 20 32 ✓<br />

REL-2S86 1-65 22 22 46 46 70 6 27 ✓<br />

REL-2TTS39 1-34 12 12 24 24 24 10 25 ✓<br />

REL-2TTS40 1-35 12 12 24 24 24 10 25 ✓<br />

REL-2TTS50 1-36, 1-37 12 12 24 24 24 10 25 ✓<br />

REL-3P32-HL-SC 1-46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 20 ✓<br />

REL-3P32-LW-SC 1-46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />

REL-3P32-SC 1-46, 49, 50, 55, 56, 59, 60, 62, 6-6 25 25 31 37 20 20 ✓<br />

*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />

*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />

** Also includes 36" violet & grey control leads.<br />

Avail<br />

IC*<br />

Ctn.<br />

8-28<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDEX – FLUORESCENT BALLASTS<br />

CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />

Catalog<br />

Number<br />

See<br />

Page<br />

No. Black White Blue Red Yellow<br />

Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />

Tolerance: +2", -1"<br />

Blue/<br />

White<br />

Black/<br />

White<br />

Yellow/<br />

Blue<br />

Brown<br />

Red/<br />

White<br />

Orange Orange/<br />

Black<br />

Units<br />

Std.<br />

Ctn.<br />

Shipping Data<br />

Weight<br />

Std.<br />

Ctn. (lbs)<br />

REL-3S40-RH-TP 1-66, 1-67 22 22 26 36 26 36 10 28 ✓<br />

REL-4P32-LW-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />

REL-4P32-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63, 6-6 25 25 31 31 39 20 20 ✓<br />

RELB-2S40-SC 1-67, 6-4 22 22 26 26 36 20 24 ✓<br />

REZ-132-SC 2-10 22 46 26 22 20 20 ✓<br />

REZ-154 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

REZ-1Q18-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

REZ-1Q18-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

REZ-1T42-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

REZ-1T42-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

REZ-1T42-M2-LD-K 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16 ✓<br />

REZ-1TTS40-SC 2-8 12 24 24 12 20 20<br />

REZ-2Q18-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

REZ-2Q18-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

REZ-2Q26-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

REZ-2Q26-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

REZ-2Q26-M2-LD-K 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16 ✓<br />

REZ-2S32-SC 2-10 22 22 26 26 46 20 20 ✓<br />

REZ-2S54 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

REZ-2T42-M3-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 18<br />

REZ-2T42-M3-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 22<br />

REZ-2TTS40-SC 2-8 12 12 24 24 24 20 20<br />

REZ-3S32-SC 2-10 22 22 26 46 26 46 20 20 ✓<br />

RIF-1 3-12 6 (2) 6 6 24 22<br />

RK-132-TP 1-58 22 35 23 22 10 35 ✓<br />

RK-2S32-TP 1-59 22 22 26 26 36 10 38 ✓<br />

RK-2S34-TP 1-67 12 12 12 12 12 10 38 ✓<br />

RL-140-TP 3-8, 3-10, 3-30 36 36 25 10 20 42 ✓<br />

RL-2SP20-TP 3-27, 3-28 15 15 15 15 18 20 50 ✓<br />

RL-3SP20-TP 3-27, 3-28 12 12 15 15 18 18 10 39 ✓<br />

RLCS-140-TP-W 3-30 11 11 11 10 10 21 ✓<br />

RLQ-120-TP 3-27, 3-28 18 18 12 10 20 42 ✓<br />

RLQS-122-TP-W 3-30 13/11 11 11 13 10 22 ✓<br />

RM-2S35-TP 3-9, 3-10, 3-11 22 22 26 26 36 10 35 ✓<br />

RM-2SP30-TP 3-8 18 18 17 17 26 10 37 ✓<br />

RMB-1P13-L2 1-26, 27, 29, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 50 8<br />

RMB-1P13-S1 1-26, 27, 29, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 75 10<br />

RMB-1P13-S2-H 1-26, 27, 29, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 60 11<br />

RMB-1P26-S2 1-28, 31, 34, 42, 67, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 60 11<br />

RMB-2P13-L2 1-26, 27, 29, 30, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 50 10<br />

RMB-2P13-S2 1-26, 27, 29, 30, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 60 11<br />

RMB-2P13-S3-H 1-26, 27, 29, 30, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 40 9<br />

RMS-22-32-TP-W 3-30 15 15 10 10 10 10 26 ✓<br />

RMS-32-40-TP-W 3-30 10 10 10 10 10 10 26 ✓<br />

ROP-2P32-LW-SC 1-44, 45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />

ROP-2P32-SC 1-44, 45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 24 ✓<br />

ROP-3P32-LW-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62, 63 25 25 31 37 20 28 ✓<br />

ROP-3P32-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62, 63 25 25 31 37 20 20 ✓<br />

ROP-4P32-HL-90C 1-46, 47, 50, 51, 60, 61, 63 25 25 31 31 39 10 20<br />

ROP-4P32-LW-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />

ROP-4P32-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 20 ✓<br />

RQM-2S40-TP 6-14 22 22 26 26 36 10 35<br />

RS-110-TP 3-13, 14, 15, 16, 17 22 70 46 22 6 59 ✓<br />

RS-22-32-TP-W 3-30 15 15 10 10 10 10 26 ✓<br />

RS-2S100-TP 6-6 18 18 33 33 51 6 66<br />

RS-2S200-FO 3-39 6.5 6.5 6.5 6.5 6.5 1 20 ✓<br />

RS-2S200-TP 3-18, 3-19, 6-6 22 22 44 44 68 4 60 ✓<br />

RS-32-40-TP-W 3-30 10 10 10 10 10 10 26 ✓<br />

RSM-175-S-TP 3-22, 3-23 70 46 19 10 62 ✓<br />

RZT-154 2-13, 2-14 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

RZT-1TTS40 ** 2-13 12 24 24 12 10 20<br />

*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />

*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />

** Also includes 36" violet & grey control leads.<br />

Avail<br />

IC*<br />

Ctn.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-29


INDEX – FLUORESCENT BALLASTS<br />

REFERENCE<br />

MATERIALS<br />

CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />

Catalog<br />

Number<br />

See<br />

Page<br />

No. Black White Blue Red Yellow<br />

Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />

Tolerance: +2", -1"<br />

Blue/<br />

White<br />

Black/<br />

White<br />

Yellow/<br />

Blue<br />

Brown<br />

Red/<br />

White<br />

Orange Orange/<br />

Black<br />

Units<br />

Std.<br />

Ctn.<br />

Shipping Data<br />

Weight<br />

Std.<br />

Ctn. (lbs)<br />

RZT-2S54 2-13, 2-14 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

RZT-2TTS40 ** 2-13 12 12 24 24 24 10 20<br />

SM-140-S-TP 3-21 34 22 10 6 40 ✓<br />

SM-151-S-TP 3-20 68 44 10 6 54<br />

SM-2E40-S-TP 3-21 41 41 23 23 10 58 ✓<br />

SM-2E51-S-TP 3-20 70 70 46 46 6 45 ✓<br />

SM-2E57-S-TP 3-22 55 55 36 36 6 45<br />

SM-2E75-S-TP 6-16 70 70 46 46 36 6 45<br />

TM-2S40-TP 6-14 22 22 26 26 36 10 40<br />

V-140-TP 3-7, 3-9, 3-10 12 12 12 12 10 36 ✓<br />

V-1BP27-TP 3-37 12 12 12 12 10 36<br />

V-1BP39-TP 3-37 12 12 12 12 10 36<br />

V-1BP40-TP 3-37 18 28 28 18 10 36 ✓<br />

V-1P32-TP 3-5, 3-6 18 36 23 18 10 37 ✓<br />

V-1P817-TP 3-5, 3-6, 3-37 18 17 17 18 10 36<br />

V-1P825-TP 3-5, 3-6 18 24 24 18 10 36<br />

V-1P840-TP 3-5 18 44 28 18 10 37<br />

V-1U40-TP 3-11 12 12 12 12 10 36 ✓<br />

V-2BP27-TP 3-37 12 12 24 24 24 10 37<br />

V-2BS39-TP 3-37 12 12 24 24 24 10 37<br />

V-2BS40-TP 3-37 20 20 24 24 36 10 37 ✓<br />

V-2E60-S-TP 3-23 12 12 12 12 12 6 49 ✓<br />

V-2E75-S-TP 3-22, 3-23 12 12 12 12 12 6 49 ✓<br />

V-2P32-TP 3-5, 3-6 20 20 24 24 36 10 37 ✓<br />

V-2P817-TP 3-5, 3-6, 3-37 10 10 14 14 26 10 37<br />

V-2P825-TP 3-5, 3-6 12 12 20 20 32 10 37<br />

V-2P840-TP 3-5 20 20 28 28 44 10 37<br />

V-2S110-TP 3-16, 3-17 22 22 46 46 70 6 71 ✓<br />

V-2S34-TP 3-9, 3-10, 3-11 12 12 12 12 12 10 36 ✓<br />

V-2S40-TP 3-7, 3-9, 3-10, 3-11 12 12 12 12 12 10 36 ✓<br />

V-2SP30-TP 3-8 18 18 17 17 26 10 37 ✓<br />

V-3S34-TP 3-9 20 20 24 36 24 36 10 37 ✓<br />

VC-2E75-S-TP 3-22, 3-23 12 12 12 12 6 49 ✓<br />

VC-2S102-FO 3-39 6.5 6.5 6.5 6.5 6.5 1 17 ✓<br />

VC-2S102-TP 3-18, 3-19 18 18 43 43 19 4 47 ✓<br />

VC-2S110-FO 3-38 6.5 6.5 6.5 6.5 6.5 1 17 ✓<br />

VC-2S200-TP 3-18, 3-19 22 22 44 44 68 4 60 ✓<br />

VC-2S85-TP 3-13, 14, 15, 16, 17 22 22 47 47 70 6 60 ✓<br />

VCN-1S32-SC 1-44, 1-48, 1-54, 1-58 25 36 26 25 20 28 ✓<br />

VCN-1TTP40-SC 1-35 25 30 30 25 20 28 ✓<br />

VCN-2P59 1-64 22 22 46 70 10 28 ✓<br />

VCN-2S32-SC 1-45, 1-49, 1-55, 1-59 25 25 26 26 36 20 28 ✓<br />

VCN-2TTP40-SC 1-35 25 25 30 30 20 28 ✓<br />

VCN-3S32-SC 1-46, 1-50, 1-56, 1-60 25 25 46 36 36 36 20 28 ✓<br />

VCN-3TTP40-SC 1-35 25 25 30 30 20 28 ✓<br />

VCN-4S32-SC 1-47, 1-51, 1-57, 1-61 25 25 36 36 46 36 46 20 28 ✓<br />

VEL-1P32-HL-SC 1-44, 48, 54, 58, 62 25 31 37 25 20 32 ✓<br />

VEL-1P32-LW-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 32 ✓<br />

VEL-1P32-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 24 ✓<br />

VEL-1S40-SC 1-66, 1-67 22 36 26 22 20 32 ✓<br />

VEL-1TTS39 1-34 12 24 24 12 10 25 ✓<br />

VEL-1TTS40 1-35 12 24 24 12 10 25 ✓<br />

VEL-1TTS50 1-36, 1-37 12 24 24 12 10 25 ✓<br />

VEL-2P17-RH-TP 1-44, 1-45 22 22 24 24 10 25 ✓<br />

VEL-2P32-HL-SC 1-45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />

VEL-2P32-LW-SC 1-45, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />

VEL-2P32-SC 1-45, 48, 49, 54, 55, 58, 59 25 25 31 37 20 24 ✓<br />

VEL-2P59-SC 1-64 22 22 46 70 20 20 ✓<br />

VEL-2P59-S-RH-TP 1-64 22 22 46 70 10 28 ✓<br />

VEL-2P75-S 1-68 22 22 46 70 6 27 ✓<br />

*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />

*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />

** Also includes 36" violet & grey control leads.<br />

Avail<br />

IC*<br />

Ctn.<br />

8-30<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDEX – FLUORESCENT BALLASTS<br />

CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />

Catalog<br />

Number<br />

See<br />

Page<br />

No. Black White Blue Red Yellow<br />

Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />

Tolerance: +2", -1"<br />

Blue/<br />

White<br />

Black/<br />

White<br />

Yellow/<br />

Blue<br />

Brown<br />

Red/<br />

White<br />

Orange Orange/<br />

Black<br />

Units<br />

Std.<br />

Ctn.<br />

Shipping Data<br />

Weight<br />

Std.<br />

Ctn. (lbs)<br />

VEL-2S110 1-69 22 22 46 46 70 6 27 ✓<br />

VEL-2S40-SC 1-66, 1-67 22 22 26 26 36 20 32 ✓<br />

VEL-2S86 1-65 22 22 46 46 70 6 27 ✓<br />

VEL-2TTS39 1-34 12 12 24 24 24 10 25 ✓<br />

VEL-2TTS40 1-35 12 12 24 24 24 10 25 ✓<br />

VEL-2TTS50 1-36, 1-37 12 12 24 24 24 10 25 ✓<br />

VEL-3P32-HL-SC 1-46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 20 ✓<br />

VEL-3P32-LW-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />

VEL-3P32-SC 1-46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 20 ✓<br />

VEL-3S40-RH-TP 1-66, 1-67 22 22 26 36 26 36 10 28 ✓<br />

VEL-4P32-LW-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />

VEL-4P32-SC 1-47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 20 ✓<br />

VEZ-132-SC 2-10 22 46 26 22 20 20 ✓<br />

VEZ-154 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

VEZ-1Q18-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

VEZ-1Q18-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

VEZ-1T42-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

VEZ-1T42-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

VEZ-1T42-M2-LD-K 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16 ✓<br />

VEZ-1TTS40-SC 2-8 12 24 24 12 20 20<br />

VEZ-2Q18-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

VEZ-2Q18-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

VEZ-2Q26-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 14<br />

VEZ-2Q26-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16<br />

VEZ-2Q26-M2-LD-K 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 16 ✓<br />

VEZ-2S32-SC 2-10 22 22 26 26 46 20 20 ✓<br />

VEZ-2S54 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

VEZ-2T42-M3-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 16 18<br />

VEZ-2T42-M3-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 20 22<br />

VEZ-2TTS40-SC 2-8 12 12 24 24 24 20 20<br />

VEZ-3S32-SC 2-10 22 22 26 46 26 46 20 20 ✓<br />

VH-1B13-TP-BLS 3-34 7 7 7 27 38<br />

VH-1B13-TP-W 3-34 15 15 15 24 34 ✓<br />

VH-1B9-TP-BLS 3-33 7 7 7 27 30<br />

VH-1B9-TP-W 3-33 15 15 15 24 26<br />

VH-1Q18-TP-BLS 3-35 7 7 7 27 40<br />

VH-1Q18-TP-W 3-35 15 15 15 24 36<br />

VH-1Q26-TP-BLS 3-35 7 7 7 27 40<br />

VH-1Q26-TP-W 3-35 15 15 15 24 36 ✓<br />

VH-2B13-TP-BLS 3-34 7 7 7 27 40<br />

VH-2B13-TP-W 3-34 15 15 15 24 36<br />

VH-2B9-TP-BLS 3-33 7 7 7 27 32<br />

VH-2B9-TP-W 3-33 15 15 15 24 29<br />

VH-2Q18-TP-BLS 3-35 7 7 7 10 33<br />

VH-2Q18-TP-W 3-35 15 15 15 10 33<br />

VH-2Q26-TP-BLS 3-35 7 7 7 10 36<br />

VH-2Q26-TP-W 3-35 15 15 15 10 36<br />

VHM-1P20-TP 3-27, 3-28 8 10 10 8 10 32 ✓<br />

VK-132-TP 1-58 22 35 23 22 10 35 ✓<br />

VK-2S32-TP 1-59 22 22 26 26 36 10 38 ✓<br />

VK-2S34-TP 1-67 12 12 12 12 12 10 38 ✓<br />

VL-1B13-TP-BLS 3-34 7 7 27 38<br />

VL-1B13-TP-W 3-34 15 15 24 34 ✓<br />

VL-1B9-TP-BLS 3-33 7 7 27 32<br />

VL-1B9-TP-W 3-33 15 15 24 29 ✓<br />

VL-1Q18-TP-BLS 3-35 7 7 27 38<br />

VL-1Q18-TP-W 3-35 15 15 24 34<br />

VL-1Q26-TP-BLS 3-35 7 7 27 43<br />

VL-1Q26-TP-W 3-35 15 15 24 38<br />

VLO-13-TP 3-31, 3-32 15 15 72 72 ✓<br />

VLO-2S13-TP 3-31 7 7 20 26 ✓<br />

*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />

*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />

** Also includes 36" violet & grey control leads.<br />

Avail<br />

IC*<br />

Ctn.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-31


INDEX – FLUORESCENT BALLASTS<br />

CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />

Catalog<br />

Number<br />

See<br />

Page<br />

No. Black White Blue Red Yellow<br />

Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />

Tolerance: +2", -1"<br />

Blue/<br />

White<br />

Black/<br />

White<br />

Yellow/<br />

Blue<br />

Brown<br />

Red/<br />

White<br />

Orange Orange/<br />

Black<br />

Units<br />

Std.<br />

Ctn.<br />

Shipping Data<br />

Weight<br />

Std.<br />

Ctn. (lbs)<br />

VLQ-106F-TP 3-27 10 10 10 10 20 40 ✓<br />

VM-1P30-TP 3-8 18 26 17 18 10 34 ✓<br />

VM-2SP20-TP 3-27, 3-28 10 10 13 13 16 10 34 ✓<br />

VM-2SP30-TP 3-8 18 18 17 17 26 10 36 ✓<br />

VOP-2P32-LW-SC 1-44, 45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />

VOP-2P32-SC 1-44, 45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 24 ✓<br />

VOP-3P32-LW-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62, 63 25 25 31 37 20 28 ✓<br />

VOP-3P32-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62, 63 25 25 31 37 20 20 ✓<br />

VOP-4P32-HL-90C 1-47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 10 20<br />

VOP-4P32-LW-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />

VOP-4P32-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 20 ✓<br />

VQM-2S40-TP 6-14 22 22 26 26 36 10 35<br />

VS-110-TP 3-13, 14, 15, 16, 17 22 40 46 22 6 59 ✓<br />

VS-2S200-FO 3-39 6.5 6.5 6.5 6.5 6.5 1 20 ✓<br />

VS-2S200-TP 3-18, 3-19 22 22 44 44 68 4 60 ✓<br />

VSB-0412-12-BL-TP 3-40 18 18 33 33 51 1 12 ✓<br />

VSB-0620-24-BL-TP 3-40 24 24 75 46 75 46 46 1 12 ✓<br />

VSB-1224-24-BL-TP 3-40 24 24 74 32 70 52 78 1 14 ✓<br />

VSB-1240-46-BL-TP 3-40 24 24 50 80 70 50 50 50 50 1 21 ✓<br />

VSB-2040-24-BL-TP 3-40 24 24 80 80 72 54 72 1 21 ✓<br />

VSB-2448-46-BL-TP 3-40 24 24 50 50 70 50 50 50 50 1 21 ✓<br />

VSM-175-S-TP 3-22, 3-23 70 48 10 10 62 ✓<br />

VSM-2E40-S-TP 3-21 25 35 23 23 35 10 58 ✓<br />

VSM-2E75-S-TP 6-16 19 70 46 46 70 6 45<br />

VZT-154 2-13, 2-14 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

VZT-180 2-13, 2-14 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

VZT-1TTS40 ** 2-13 12 24 24 12 10 20<br />

VZT-2S54 2-13, 2-14 N N N N No N Leads N- Poke in NConnectors<br />

N N N N N 12 12<br />

VZT-2TTS40 ** 2-13 12 12 24 24 24 10 20<br />

VZT-4S32-HL ** 2-16 12 12 12 15 59 15 45 6 12<br />

X-140-TP 3-7, 3-9, 3-10 22 35 23 22 10 36<br />

XHM-1P20-TP 6-17 8 10 10 8 10 32<br />

XM-2SP20-TP 6-17 10 10 13 13 16 10 34<br />

XQM-2S40-TP 3-7, 3-9, 3-10, 3-11 22 22 26 26 36 10 34<br />

XSM-2E75-S-TP 3-22, 3-23 19 70 46 46 70 6 49<br />

XTH-1B13-TP-W 6-17 15 15 15 24 36<br />

YHQM-1P40-TP 3-7, 3-8, 3-10 18 35 23 18 10 36<br />

YK-2S32-TP 1-59 22 22 26 26 36 10 38<br />

YQM-2S40-TP 3-7, 3-9, 3-10, 3-11 18 18 24 24 36 10 35 ✓<br />

YS-2S110-TP 3-16, 3-17 22 22 46 46 70 6 61<br />

YS-2S85-TP 3-13, 14, 15, 16, 17 (2) 22 47 47 70 6 60<br />

YSM-2E75-S-TP 3-22, 3-23 19 70 46 46 70 6 49<br />

Avail<br />

IC*<br />

Ctn.<br />

*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />

*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />

** Also includes 36" violet & grey control leads.<br />

REFERENCE<br />

MATERIALS<br />

*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />

*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />

8-32<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDEX – HID BALLASTS<br />

CATALOG NUMBER TO PAGE NUMBER<br />

Catalog<br />

Number<br />

Page<br />

Number<br />

7180J9 5-37<br />

71A0280 5-46<br />

71A0490 5-46<br />

71A0490-001D 5-7, 5-46<br />

71A04F0 5-46<br />

71A0590 5-47<br />

71A0590-001D 5-7, 5-47<br />

71A05F0 5-47<br />

71A0790 5-47<br />

71A0790-001D 5-7, 5-47<br />

71A07F0 5-47<br />

71A1580 5-14<br />

71A1800 5-14<br />

71A1800-001 5-7, 5-14<br />

71A2080 5-14<br />

71A2303 5-14<br />

71A2501 5-14<br />

71A2541 5-14<br />

71A2571-001D 5-7, 5-14<br />

71A2591 5-14<br />

71A25A1 5-14<br />

71A25A1-001D 5-9, 5-14<br />

71A2800 5-14<br />

71A2800-001 5-7, 5-14<br />

71A29D1 5-15<br />

71A29D1-001D 5-9, 5-15<br />

71A3002 5-15<br />

71A3042 5-15<br />

71A3042-001D 5-7, 5-15<br />

71A3072-001D 5-7, 5-15<br />

71A3092 5-15<br />

71A30D2 5-15<br />

71A30D2-001D 5-9, 5-15<br />

71A3301 5-15<br />

71A3301-001 5-7, 5-15<br />

71A3304-791 5-8<br />

71A3325 5-15<br />

71A3325-791 5-8<br />

71A3502 5-16<br />

71A3542 5-16<br />

71A3542-001D 5-7, 5-16<br />

71A3542-T 5-16<br />

71A3572-001D 5-7, 5-16<br />

71A3592 5-16<br />

71A35D2 5-16<br />

71A35D2-001D 5-9, 5-16<br />

71A35J2 5-16<br />

71A3801-791 5-8<br />

71A3802 5-16<br />

71A4041 5-17<br />

71A4041-001D 5-7, 5-17<br />

71A4041-T 5-17<br />

71A4071-001D 5-7, 5-17<br />

71A4091 5-17<br />

71A40D1 5-17<br />

71A40D1-001D 5-9, 5-17<br />

71A4300-001 5-7, 5-17<br />

71A4330-001 5-7, 5-17<br />

71A4340-001 5-7, 5-17<br />

71A5005-P 5-18<br />

71A5037-BP 5-18<br />

71A5037-J 5-18<br />

71A5037-P 5-18<br />

71A5040-001 5-7, 5-17<br />

71A5070-001 5-7, 5-17<br />

71A5081 5-18<br />

71A5105-P 5-18<br />

71A5137-BP 5-18<br />

71A5137-J 5-18<br />

71A5137-P 5-18<br />

71A5181 5-18<br />

Catalog<br />

Number<br />

Page<br />

Number<br />

71A5181-001D 5-5, 5-18<br />

71A5205-P 5-19<br />

71A5237-BP 5-19<br />

71A5237-J 5-19<br />

71A5237-P 5-19<br />

71A5280 5-19<br />

71A5281 5-19<br />

71A5282 5-19<br />

71A5292 5-19<br />

71A5292-001D 5-5, 5-19<br />

71A52A2 5-19<br />

71A52A2-001D 5-9, 5-19<br />

71A52C0 5-19<br />

71A52C1 5-19<br />

71A52H2 5-19<br />

71A5337-BP 5-20<br />

71A5337-J 5-20<br />

71A5337-P 5-20<br />

71A5340-T 5-20<br />

71A5380 5-20<br />

71A5383 5-20<br />

71A5390 5-20<br />

71A5390-001D 5-5, 5-20<br />

71A53A0 5-20<br />

71A53A0-001D 5-9, 5-20<br />

71A53H0 5-20<br />

71A5437-BP 5-21<br />

71A5437-J 5-21<br />

71A5437-P 5-21<br />

71A5442-T 5-21<br />

71A5480 5-21<br />

71A5482 5-21<br />

71A5486 5-21<br />

71A5490 5-21<br />

71A5492 5-21<br />

71A5492-001D 5-5, 5-21<br />

71A54A2 5-21<br />

71A54A3 5-21<br />

71A54C0 5-21<br />

71A5500 5-22<br />

71A5504 5-22<br />

71A5530 5-22<br />

71A5534-T 5-22<br />

71A5540 5-22<br />

71A5540-001D 5-5, 5-22<br />

71A5540-T 5-22<br />

71A5543-T 5-22<br />

71A5544-T 5-22<br />

71A5570-001D 5-5, 5-22<br />

71A5580 5-22<br />

71A5590 5-22<br />

71A5593 5-22<br />

71A5593-001D 5-5, 5-22<br />

71A55A0 5-22<br />

71A55A0-001D 5-9, 5-22<br />

71A55A3 5-22<br />

71A55B4-T 5-22<br />

71A55H0 5-22<br />

71A5634-T 5-23<br />

71A5637-001D 5-5, 5-23<br />

71A5637-BP 5-23<br />

71A5642-T 5-23<br />

71A5692 5-23<br />

71A5692-001D 5-5, 5-23<br />

71A5693 5-23<br />

71A56A2 5-23<br />

71A56A3 5-23<br />

71A5700 5-24<br />

71A5701 5-24<br />

71A5704 5-25<br />

71A5724-T 5-25<br />

Catalog<br />

Number<br />

Page<br />

Number<br />

71A5730 5-24<br />

71A5731 5-24<br />

71A5734-T 5-25<br />

71A5737-001D 5-5, 5-25<br />

71A5737-BP 5-25<br />

71A5740 5-24<br />

71A5740-001D 5-5, 5-24<br />

71A5740-T 5-24<br />

71A5741 5-24<br />

71A5741-001D 5-5, 5-24<br />

71A5742-T 5-25<br />

71A5744-T 5-25<br />

71A5750 5-24<br />

71A5750-001D 5-5, 5-24<br />

71A5770-001D 5-5, 5-24<br />

71A5771-001D 5-5, 5-24<br />

71A5780 5-24<br />

71A5790 5-24<br />

71A5791 5-24<br />

71A5792 5-25<br />

71A5792-001D 5-5, 5-25<br />

71A57A0 5-24<br />

71A57A0-001D 5-9, 5-24<br />

71A57A2 5-25<br />

71A57B4-T 5-25<br />

71A57E6 5-24<br />

71A57H0 5-24<br />

71A5837-001D 5-5, 5-26<br />

71A5837-BP 5-26<br />

71A5842-001DT 5-5, 5-26<br />

71A5842-T 5-26<br />

71A5892 5-26<br />

71A5892-001D 5-5, 5-26<br />

71A5892-LL 5-26<br />

71A58A2 5-26<br />

71A58H2 5-26<br />

71A5934-T 5-26<br />

71A5937-001D 5-5, 5-26<br />

71A5937-BP 5-26<br />

71A5943-T 5-26<br />

71A5993 5-26<br />

71A5993-001D 5-5, 5-26<br />

71A59A3 5-26<br />

71A6001 5-27<br />

71A6004 5-28<br />

71A6031 5-27<br />

71A6034-T 5-28<br />

71A6037-001D 5-5, 5-27<br />

71A6037-B 5-27<br />

71A6041 5-27<br />

71A6041-001D 5-5, 5-27<br />

71A6041-T 5-27<br />

71A6042-T 5-28<br />

71A6044-T 5-28<br />

71A6051 5-27<br />

71A6051-001D 5-5, 5-27<br />

71A6071-001D 5-5, 5-27<br />

71A6081 5-27<br />

71A6091 5-27<br />

71A6092 5-28<br />

71A6092-001D 5-5, 5-28<br />

71A6092-LL 5-28<br />

71A60A1 5-27<br />

71A60A1-001D 5-9, 5-27<br />

71A60A2 5-28<br />

71A60B4-T 5-28<br />

71A60E4-T 5-28<br />

71A60E6 5-27<br />

71A60F6 5-27<br />

71A60H1 5-27<br />

71A6137-001D 5-5, 5-28<br />

Catalog<br />

Number<br />

Page<br />

Number<br />

71A6137-BP 5-28<br />

71A6334-T 5-28<br />

71A6337-001D 5-5<br />

71A6337-BP 5-28<br />

71A6342-001D 5-5<br />

71A6343-T 5-28<br />

71A6382-001D 5-5<br />

71A6393 5-28<br />

71A6393-001D 5-5<br />

71A63A3 5-28<br />

71A6490 5-29<br />

71A6498 5-29<br />

71A64E2 5-29<br />

71A64F0-T 5-29<br />

71A64F2 5-29<br />

71A64F2-001D 5-5, 5-29<br />

71A64F2-T 5-29<br />

71A64F8-T 5-29<br />

71A6502 5-30<br />

71A6532 5-30<br />

71A6542 5-30<br />

71A6542-001 5-5, 5-30<br />

71A6542-T 5-30<br />

71A6552 5-30<br />

71A6552-001 5-5, 5-30<br />

71A6572-001 5-5, 5-30<br />

71A6590 5-30<br />

71A6591 5-30<br />

71A6592 5-30<br />

71A6593 5-30<br />

71A65A2 5-30<br />

71A65A2-001 5-9, 5-30<br />

71A65E6-T 5-30<br />

71A65F0-T 5-30<br />

71A65F1-T 5-30<br />

71A65F3-T 5-30<br />

71A65J2 5-30<br />

71A6702 5-31<br />

71A6732 5-31<br />

71A6742 5-31<br />

71A6742-001 5-5, 5-31<br />

71A6772-001 5-5, 5-31<br />

71A6792 5-31<br />

71A67A2 5-31<br />

71A67A2-001 5-9, 5-31<br />

71A67J2 5-31<br />

71A6890 5-31<br />

71A68F0 5-31<br />

71A69EO 5-31<br />

71A69H0 5-31<br />

71A7707 5-32<br />

71A7707-001DB 5-6, 5-32<br />

71A7707-B 5-32<br />

71A7801 5-33<br />

71A7801-001D 5-6, 5-33<br />

71A7805 5-33<br />

71A7807 5-33<br />

71A7807-001DB 5-6, 5-33<br />

71A7807-B 5-33<br />

71A7901 5-34<br />

71A7907 5-34<br />

71A7907-001DB 5-6, 5-34<br />

71A7907-791 5-8<br />

71A7907-B 5-34<br />

71A7941 5-34<br />

71A7950 5-35<br />

71A7971-001D 5-6, 5-34<br />

71A7988 5-35<br />

71A7991 5-34<br />

71A7991-001DC 5-6<br />

71A79A1 5-34<br />

Catalog<br />

Number<br />

Page<br />

Number<br />

71A79A1-001D 5-9, 5-34<br />

71A79E6 5-35<br />

71A79H8 5-35<br />

71A79J1 5-34<br />

71A8001 5-36<br />

71A8005 5-36<br />

71A8005 5-36<br />

71A8007 5-36<br />

71A8007-001DB 5-6,, 5-36<br />

71A8007-791 5-8<br />

71A8007-B 5-36<br />

71A8041 5-36<br />

71A8041-001D 5-6, 5-36<br />

71A8048-T 5-37<br />

71A8050 5-37<br />

71A8056 5-37<br />

71A8060 5-37<br />

71A8071-001D 5-6, 5-36<br />

71A8080 5-37<br />

71A8088 5-37<br />

71A8091 5-36<br />

71A8091-001DC 5-6<br />

71A80A1 5-36<br />

71A80A1-001D 5-9, 5-36<br />

71A80EG 5-37<br />

71A80H8 5-37<br />

71A80J1 5-36<br />

71A80J8 5-37<br />

71A8102 5-38<br />

71A8107 5-38<br />

71A8107-001DB 5-6, 5-38<br />

71A8107-791 5-8<br />

71A8107-B 5-38<br />

71A8132 5-38<br />

71A8142 5-38<br />

71A8142-001D 5-6, 5-38<br />

71A8142-T 5-38<br />

71A8146-001D 5-6, 5-39<br />

71A8148 5-39<br />

71A8150 5-39<br />

71A8160 5-39<br />

71A8172-001D 5-6, 5-38<br />

71A8176-001D 5-6, 5-39<br />

71A8180 5-39<br />

71A8188 5-39<br />

71A8192 5-38<br />

71A8192-001DC 5-6<br />

71A8196 5-39<br />

71A81A2 5-38<br />

71A81A2-001D 5-9, 5-38<br />

71A81E6 5-39<br />

71A81H8 5-39<br />

71A81J2 5-38<br />

71A81J9 5-39<br />

71A8201 5-41<br />

71A8231 5-41<br />

71A8241 5-41<br />

71A8241-001D 5-7, 5-41<br />

71A8241-T 5-41<br />

71A8250 5-41<br />

71A8251 5-41<br />

71A8251-001D 5-7, 5-41<br />

71A8260 5-41<br />

71A8271-001D 5-7, 5-41<br />

71A8280 5-41<br />

71A8281 5-41<br />

71A8291 5-41<br />

71A8291-001DC 5-7<br />

71A8296 5-41<br />

71A82A1 5-41<br />

71A82A1-001D 5-9, 5-41<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-33


INDEX – HID BALLASTS<br />

REFERENCE<br />

MATERIALS<br />

CATALOG NUMBER TO PAGE NUMBER<br />

Catalog<br />

Number<br />

Page<br />

Number<br />

71A82E6 5-41<br />

71A82H1 5-41<br />

71A82J9 5-41<br />

71A8341 5-42<br />

71A8350 5-42<br />

71A8351 5-42<br />

71A8360 5-42<br />

71A8371-001D 5-7, 5-42<br />

71A8391 5-42<br />

71A8403 5-43<br />

71A8433 5-43<br />

71A8440-T 5-43<br />

71A8443 5-43<br />

71A8443-001D 5-7, 5-43<br />

71A8443-001DC 5-7<br />

71A8443-T 5-43<br />

71A8450 5-43<br />

71A8453 5-43<br />

71A8453-001D 5-7, 5-43<br />

71A8456 5-43<br />

71A8460 5-43<br />

71A8473-001D 5-7, 5-43<br />

71A8480 5-43<br />

71A8493 5-43<br />

71A8493-001DC 5-7<br />

71A84A3 5-43<br />

71A84A3-001D 5-9, 5-43<br />

71A84E6 5-43<br />

71A84H3 5-43<br />

71A85E5 5-44<br />

71A85E6 5-44<br />

71A85E8 5-44<br />

71A85F5 5-44<br />

71A85F6 5-44<br />

71A85F8 5-44<br />

71A86E5 5-44<br />

71A86E5 5-29<br />

71A86F5 5-44<br />

71A86F5 5-29<br />

71A8703 5-45<br />

71A8733 5-45<br />

71A8743 5-45<br />

71A8743-001 5-7, 5-45<br />

71A8743-001C 5-7<br />

71A8753 5-45<br />

71A8753-001 5-7, 5-45<br />

71A8773-001 5-7, 5-45<br />

71A8793 5-45<br />

71A8793-001C 5-7<br />

71A87A3 5-45<br />

71A87A3-001 5-9, 5-45<br />

71A87J3 5-45<br />

71A8940 5-40<br />

71A8940-001D 5-7, 5-40<br />

71A8941 5-40<br />

71A8950 5-40<br />

71A8954 5-40<br />

71A8964 5-40<br />

71A8970-001D 5-7, 5-40<br />

71A8990 5-40<br />

71A8991 5-40<br />

71A9325 5-55<br />

71A9740 5-55<br />

71A9741 5-55<br />

71A9742 5-55<br />

71A9743 5-55<br />

71A9744 5-55<br />

71A9749 5-55<br />

71A9833 5-55<br />

71A9839 5-55<br />

71A9846 5-55<br />

Catalog<br />

Number<br />

Page<br />

Number<br />

71A9847 5-33, 5-55<br />

71A9862 5-55<br />

71A9876 5-36, 5-55<br />

71A9877 5-55<br />

71A9885 5-55<br />

71A9900 5-55<br />

72C2584-NP 5-56<br />

72C2584-NP-001 5-56<br />

72C25C4-NP 5-56<br />

72C29C4-NP 5-56<br />

72C3084-NP 5-56<br />

72C3084-NP-001 5-56<br />

72C30C4-NP 5-56<br />

72C3584-NP 5-56<br />

72C3584-NP-001 5-56<br />

72C4083-NP 5-56<br />

72C4083-NP-001 5-56<br />

72C5005-NP 5-57<br />

72C5005-NP-BLS 5-57<br />

72C5081-NP 5-57<br />

72C5181-NP 5-57<br />

72C5181-NP-001 5-57<br />

72C51C1-NP 5-57<br />

72C5280-NP 5-57<br />

72C5280-NP-001 5-57<br />

72C5281-NP 5-57<br />

72C5281-NP-900 5-57<br />

72C5282-NP 5-57<br />

72C5282-NP-001 5-57<br />

72C5282-NP-900 5-57<br />

72C52C0-NP 5-57<br />

72C52C1-NP-900 5-57<br />

72C52C2-NP 5-57<br />

72C5381-NP 5-57<br />

72C5381-NP-001 5-57<br />

72C5381-NP-900 5-57<br />

72C53C1-NP 5-57<br />

72C5481-NP 5-57<br />

72C5482-NP 5-57<br />

72C5482-NP-900 5-57<br />

72C54C1-NP 5-57<br />

72C54C2-NP-900 5-57<br />

72C5581-NP 5-58<br />

72C5581-NP-001 5-58<br />

72C5582-NP 5-58<br />

72C5582-NP-001 5-58<br />

72C55C1-NP 5-58<br />

72C5782-NP 5-58<br />

72C5782-NP-001 5-58<br />

72C5783-NP 5-58<br />

72C5783-NP-001 5-58<br />

72C57C2-NP 5-58<br />

72C5882-NP 5-58<br />

72C5882-NP-001 5-58<br />

72C5983-NP 5-58<br />

72C5983-NP-001 5-58<br />

72C6082-NP 5-58<br />

72C6082-NP-WC 5-58<br />

72C6182-NP 5-58<br />

72C6182-NP-001 5-58<br />

72C7705-NP 5-59<br />

72C7805-NP 5-59<br />

72C7884-NP 5-59<br />

72C7884-NP-001 5-59<br />

72C7984-NP 5-59<br />

72C7984-NP-001 5-59<br />

72C79C4-NP 5-59<br />

72C8005-NP 5-59<br />

72C8084-NP 5-59<br />

72C8084-NP-001 5-59<br />

72C80C4-NP 5-59<br />

Catalog<br />

Number<br />

Page<br />

Number<br />

72C8185-NP 5-59<br />

72C81C5-NP 5-59<br />

72C8680-NP 5-59<br />

73B2591 5-60<br />

73B3092 5-60<br />

73B3592 5-60<br />

73B4091 5-60<br />

73B5282 5-61<br />

73B5380 5-61<br />

73B5383 5-61<br />

73B5482 5-61<br />

73B5590 5-61<br />

73B55A0 5-61<br />

73B5790 5-61<br />

73B5792 5-61<br />

73B57A0 5-61<br />

73B5892 5-61<br />

73B5993 5-61<br />

73B6091 5-62<br />

73B6092 5-62<br />

73B60A1 5-62<br />

73B6590 5-62<br />

73B6592 5-62<br />

73B65A2 5-62<br />

73B7805 5-63<br />

73B8005 5-63<br />

73B8281 5-63<br />

73B8483 5-63<br />

74P1501-011P 5-64<br />

74P1801-011 5-64<br />

74P2001-011P 5-64<br />

74P2301-011 5-64<br />

74P2503-011P 5-64<br />

74P2513-011P 5-64<br />

74P2523-011P 5-64<br />

74P2533-011P 5-64<br />

74P2802-011 5-64<br />

74P2832-011 5-64<br />

74P3003-011P 5-65<br />

74P3013-011P 5-65<br />

74P3023-011P 5-65<br />

74P3033-011P 5-65<br />

74P3303-011 5-65<br />

74P3313-011 5-65<br />

74P3323-011 5-65<br />

74P3333-011 5-65<br />

74P3503-011P 5-65<br />

74P3513-011P 5-65<br />

74P3523-011P 5-65<br />

74P3533-011P 5-65<br />

74P5103-011 5-66<br />

74P5104-011P 5-66<br />

74P7702-011 5-67<br />

74P7703-011P 5-67<br />

74P7802-011 5-67<br />

74P7803-011P 5-67<br />

74P7902-011 5-67<br />

74P7903-011P 5-67<br />

74P7913-011P 5-67<br />

74P7923-011P 5-67<br />

74P7933-011P 5-67<br />

74P8002-011 5-67<br />

74P8003-011P 5-67<br />

74P8013-011P 5-67<br />

74P8023-011P 5-67<br />

74P8033-011P 5-67<br />

74P8103-011 5-67<br />

74P8104-011P 5-67<br />

77K5570-001D 5-10<br />

77K5770-001D 5-10<br />

77K5837-001D 5-10<br />

Catalog<br />

Number<br />

Page<br />

Number<br />

77K5892-001D 5-10<br />

77K5937-001D 5-10<br />

77K5993-001D 5-10<br />

77K6071-001D 5-10<br />

77K8071-001D 5-10<br />

77K8172-001D 5-10<br />

77K8271-001D 5-10<br />

77K8473-001D 5-10<br />

77L5570-001D 5-11<br />

77L5750-001D 5-11<br />

77L6051-001D 5-11<br />

77L6552-001 5-11<br />

77L8071-001D-MED 5-11<br />

77L8172-001D-MOG 5-11<br />

77L8251-001D 5-11<br />

77L8453-001D 5-11<br />

77L8753-001 5-11<br />

78E8291-001 5-68<br />

78E8443-001 5-68<br />

78E8493-001 5-68<br />

78E8743-001 5-68<br />

78E8793-001 5-68<br />

78E8940-001 5-68<br />

79W2591-001 5-69<br />

79W3542-001 5-69<br />

79W3592-001 5-69<br />

79W5590-001 5-70<br />

79W5790-001 5-70<br />

79W6041-001 5-70<br />

79W6091-001 5-70<br />

79W6341-001 5-70<br />

79W6351-001 5-70<br />

79W6542-001 5-70<br />

79W6592-001 5-70<br />

79W6742-001 5-70<br />

79W6792-001 5-70<br />

79W8192-001 5-71<br />

79W8241-001 5-71<br />

79W8291-001 5-71<br />

79W8443-001 5-71<br />

79W8493-001 5-71<br />

79W8743-001 5-71<br />

79W8793-001 5-71<br />

79W9597-001 5-71<br />

EHID<br />

Catalog<br />

Number<br />

IGNITORS<br />

Page<br />

Number<br />

IMG-100-A-BLS 4-5<br />

IMG-100-D-BLS 4-6<br />

IMG-150-H-BLS 4-6<br />

IMG-239-A-BLS 4-5<br />

IMG-39-G-BLS 4-5<br />

IMG-70-G-BLS 4-5<br />

IMH-100-A-BLS 4-5<br />

IMH-100-A-LF 4-5<br />

IMH-100-D-LF 4-6<br />

IMH-150-H-LF 4-6<br />

IMH-175-C-BLS 4-6<br />

IMH-175-C-LF 4-6<br />

IMH-200-C-LF 4-6<br />

IMH-239-A-LF 4-5<br />

IMH-39-G-LF 4-5<br />

IMH-39-J-LF 4-5<br />

IMH-50-A-BLS 4-5<br />

IMH-50-A-LF 4-5<br />

IMH-70-D-BLS 4-5<br />

IMH-70-G-LF 4-5<br />

IMH-70-J-LF 4-5<br />

IWSN-150-H-BLS 4-6<br />

IWSN-150-H-LF 4-6<br />

IZTEM4003PS-F 4-10<br />

IZTEM400EPS-F 4-10<br />

IZTEMH4003PS 4-10<br />

IZTEMH4003PS-F 4-10<br />

IZTMH-150-C-LF 4-10<br />

IZTSN-150-C-LF 4-10<br />

RMH-20-E-LF 4-5<br />

RMH-39-K-LF 4-5<br />

RMH-39-K-LFS 4-5<br />

Catalog<br />

Number<br />

Page<br />

Number<br />

6C035-IC 5-53<br />

6C050-IC 5-53<br />

6C100-IC 5-53<br />

LI501-H4-IC 5-53, 5-54<br />

LI501-J4-IC 5-51, 5-53, 5-54, 5-55<br />

LI522-H5-IC 5-51<br />

LI523-H5-IC 5-51<br />

LI533-H4-IC 5-51<br />

LI534-H5-IC 5-51<br />

LI551-H4-IC 5-53<br />

LI551-J4-IC 5-53<br />

LI561-H5 5-51<br />

LI561-H5-IC 5-51, 5-54<br />

LI571-H5-IC 5-51, 5-54<br />

LI571-J5-IC 5-55<br />

LI572-H5-IC 5-51<br />

LI573-H5 5-51<br />

LI573-H5-IC 5-51<br />

LI5xxSQ 5-52<br />

LI5xxSQR 5-52<br />

LISOD1 5-52<br />

LISOD1-IC 5-52<br />

8-34<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDEX – FLUORESCENT BALLASTS<br />

REFERENCE<br />

MATERIALS<br />

DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />

Electromagnetic Fluorescent Electromagnetic Fluorescent Electromagnetic Fluorescent<br />

Discontinued<br />

Catalog<br />

Number<br />

Current<br />

Catalog<br />

Number<br />

Page<br />

No.<br />

038-A40 - -<br />

065-A40 ASB-0620-24-BL-TP 3-40<br />

217-A40 - -<br />

268-A40 ASB-0412-12-BL-TP 3-40<br />

276-A40 - -<br />

296-A40 - -<br />

492-A40 ASB-0620-24-BL-TP 3-40<br />

494-A40 - -<br />

580-A40 - -<br />

752-A40 ASB-0620-24-BL-TP 3-40<br />

760-A40 - -<br />

762-A40 - -<br />

763-A40 - -<br />

826-A40 ASB-0620-24-BL-TP 3-40<br />

834-A40 - -<br />

843-A40 ASB-2040-24-BL-TP 3-40<br />

844-A40 ASB-1224-24-BL-TP 3-40<br />

849-A40 - -<br />

868-A40 - -<br />

902-A40 - -<br />

903-A40 - -<br />

915-A40 - -<br />

944-A40 ASB-1224-24-BL-TP 3-40<br />

957-A40 - -<br />

966-A40 ASB-0412-12-BL-TP 3-40<br />

967-A40 - -<br />

976-A40 ASB-0620-24-BL-TP 3-40<br />

977-A40 - -<br />

A-175-S RSM-175-S-TP 3-22, 3-23<br />

A-2E75-S R-2E75-S-TP 3-22, 3-23<br />

AD-240 - -<br />

ADM-251-S SM-2E51-S-TP 3-20<br />

ADM-2E40-S SM-2E40-S-TP 3-20<br />

ADM-2E75-S R-2E75-S-TP 3-22, 3-23<br />

ASB-0412-12 ASB-0412-12-BL-TP 3-40<br />

ASB-0412-12-BL ASB-0412-12-BL-TP 3-40<br />

ASB-06-20-24 ASB-06-20-24-BL-TP 3-40<br />

ASB-06-20-24-BL ASB-06-20-24-BL-TP 3-40<br />

ASB-1224-24 ASB-1224-24-BL-TP 3-40<br />

ASB-1224-24-BL ASB-1224-24-BL-TP 3-40<br />

ASB-1240-46 ASB-1240-46-BL-TP 3-40<br />

ASB-1240-46-BL ASB-1240-46-BL-TP 3-40<br />

ASB-2040-24 ASB-2040-24-BL-TP 3-40<br />

ASB-2040-24-BL ASB-2040-24-BL-TP 3-40<br />

ASB-2448-46 ASB-2448-46-BL-TP 3-40<br />

ASB-2448-46-BL ASB-2448-46-BL-TP 3-40<br />

DIM-140-L-TP - -<br />

DS-2S110 - -<br />

DS-2S200-TP - -<br />

DSC-110 - -<br />

DSC-2S100 - -<br />

DSC-2S110 - -<br />

DSM-1P40 - -<br />

DSM-2E75-S - -<br />

ESEQM-240-S - -<br />

ESM-2E40-S - -<br />

ESM-2E75-S - -<br />

G-2S34-TP G-2C34-TP 6-4<br />

G-2S86-TP - -<br />

GC-140-TP - -<br />

GC-2S40-TP - -<br />

GM-2S20-TP - -<br />

GQM-2S40-TP G-2S40-TP 3-7, 3-9 to 11<br />

GSC-2S110-TP G-2S110-TP 3-16, 3-17<br />

GSC-2S200 - -<br />

GSM-2E75-S-TP G-2E75-S-TP 3-22, 3-23<br />

H-140 L-140-F-TP 3-25, 26, 29, 36<br />

H-1Q16-TP - -<br />

HD-140 DIM-140-H-TP 3-12<br />

HM-140-TP R-140-TP 3-7, 3-9 3-10<br />

HM-2SP15 HM-2SP20-TP 3-27, 3-28<br />

HM-3P20 RL-3SP20-TP 3-27, 3-28<br />

HQM-1P40 R-140-TP 3-7, 3-9 to 10<br />

Discontinued<br />

Catalog<br />

Number<br />

Current<br />

Catalog<br />

Number<br />

Page<br />

No.<br />

HQM-2S40 R-2S40-TP 3-7, 3-9 to 11<br />

L-132 L-140-F-TP 3-25, 26, 29, 36<br />

LC-4-8-C LC-4-9-C 3-24<br />

LO-14-20-C LC-14-20-C 3-25, 3-26<br />

LO-1Q16-TP - -<br />

LO-4-8-C LC-4-9-C 3-24<br />

LQ-2S40 R-2S40-TP 3-7, 3-9 to 11<br />

LQF-140 - -<br />

MSM-175-S - -<br />

MT-2S200-TP - -<br />

MTM-2E75-S - -<br />

R-1S32-TP R-1P32-TP 3-5, 3-6<br />

R-22-32-TP RS-22-32-TP-W 3-30<br />

R-2E75-S-TP-AC R-2E75-S-TP 3-22, 3-23<br />

R-2E75-S-TP-MC R-2E75-S-TP 3-22, 3-23<br />

R-2Q18-4P-TP-BLS - -<br />

R-2Q18-4P-TP-W - -<br />

R-2Q26-4P-TP-BLS - -<br />

R-2Q26-4P-TP-W - -<br />

R-2S32-TP R-2P32-TP 3-5, 3-6<br />

R-2S40-TP-AC R-2S40-TP 3-7, 3-9 to 11<br />

R-2S40-TP-MC R-2S40-TP 3-7, 3-9 to 11<br />

R-2S65-TP ICN-2S86 1-65<br />

R-2S86-TP ICN-2S86 1-65<br />

R-32-40-TP RS-32-40-TP-W 3-30<br />

RC-140-TP - -<br />

RC-160-(FO or RO) RC-2S85-FO 3-38<br />

RC-160-TP RS-110-TP 3-13 to 3-17<br />

RC-180 - -<br />

RC-1P40-TP - -<br />

RC-2S102-RO RC-2S102-FO 3-39<br />

RC-2S110 R-2S110-TP 3-16, 3-17<br />

RC-2S110-RO RC-2S110-FO 3-38<br />

RC-2S200-(FO or RO) RS-2S200-FO 3-39<br />

RC-2S40-TP - -<br />

RC-2S85-RO RC-2S85-FO 3-38<br />

RC-2SP40-TP - -<br />

RC-3S150-TP - -<br />

RC-3S200-TP - -<br />

RC-4S155 - -<br />

RH-2S200 RS-2S200-TP 3-18, 3-19<br />

RK-134-TP - -<br />

RK-2S40-TP RK-2S34-TP 1-68<br />

RK-3S34-TP - -<br />

RLC-140 RL-140-TP 3-8, 3-10, 3-30<br />

RLCS-140 RLCS-140-TP-W 3-30<br />

RLM-2SP20 RL-2SP20-TP 3-27, 3-28<br />

RLQ-122-TP RLQS-122-TP-W 3-30<br />

RLQC-1100-CW - -<br />

RLQC-140 RL-140-TP 3-8, 3-10, 3-30<br />

RLQCS-140 RLCS-140-TP-W 3-30<br />

RM-140-TP R-140-TP 3-7, 3-9 to 10<br />

RM-2S40-TP R-2S40-TP 3-7, 3-9 to 11<br />

RQB-2S102 RC-2S102-TP 3-18, 3-19<br />

RQC-102-(FO or RO) RC-2S102-FO 3-39<br />

RQC-102-CW RC-2S102-TP 3-18, 3-19<br />

RQC-1100-CW - -<br />

RQC-2S100-CW - -<br />

RQC-2S102-(FO or RO) RC-2S102-FO 3-39<br />

RQC-2S102-CW RC-2S102-TP 3-18, 3-19<br />

RQC-3S60-CW RC-4S60-TP 3-13 to 3-16<br />

RQC-3S85-CW RC-4S60-TP 3-13 to 3-16<br />

RQM-2S40-TP R-2S40-TP 3-7, 3-9 to 11<br />

RS-110-(FO or RO) RC-2S85-FO 3-38<br />

RS-160-TP RS-110-TP 3-13 to 3-17<br />

RS-2S110-(FO or RO) RS-2S110-FO 3-39<br />

RS-2S110-TP R-2S110-TP 3-16, 3-17<br />

RS-2S40-TP R-2S40-TP 3-7, 3-9 to 11<br />

RS-2S60-TP RC-2S85-TP 3-13 to 3-17<br />

RS-2S80 - -<br />

RS-2S85 RC-2S85-TP 3-13 to 3-17<br />

RS-2S85-(FO or RO) RC-2S85-FO 3-38<br />

RS-3P40-TP - -<br />

Discontinued<br />

Catalog<br />

Number<br />

Current<br />

Catalog<br />

Number<br />

Page<br />

No.<br />

RSC-2S155-TP RC-2S200-TP 3-18, 3-19<br />

RSC-4S60 RC-4S60-TP 3-13 to 3-16<br />

RSD-140 - -<br />

RSH-115 HM-1P20-TP 3-27, 3-28<br />

RSH-120 HM-1P20-TP 3-27, 3-28<br />

RSH-180 - -<br />

RSH-1D40 - -<br />

RSH-215 HM-2SP20-TP 3-27, 3-28<br />

RSH-220 HM-2SP20-TP 3-27, 3-28<br />

RSH-225-F - -<br />

RSH-248-S SM-2E51-S-TP 3-20<br />

RSH-2E75-S R-2E75-S-TP 3-22, 3-23<br />

RSHM-130 L-140-F-TP 3-25, 26, 29, 36<br />

RSHM-140-TP R-140-TP 3-7, 3-9 to 10<br />

RSHM-175-S RSM-175-S-TP 3-22, 3-23<br />

RSHM-230-TP R-2SP30-TP 3-27, 3-28<br />

RSHM-240-TP R-2S40-TP 3-7, 3-9 to 11<br />

RSL-104 - -<br />

RSL-118-G - -<br />

RSL-122 LC-14-20-C 3-25, 3-26<br />

RSL-125 LC-25-TP 3-32<br />

RSL-131-G - -<br />

RSL-150 - -<br />

RSL-180 - -<br />

RSL-2232 - -<br />

RSL-225 - -<br />

S-240 R-2S40-TP 3-7, 3-9 to 11<br />

S-251-S-TP SM-2E51-S-TP 3-20<br />

S-269-S SM-2E51-S-TP 3-20<br />

S-275-S-TP RC-2E75-S-TP 3-22, 3-23<br />

S-285-TP - -<br />

SI-240-S-TP SM-2E40-S-TP 3-21<br />

SM-116-G - -<br />

SM-125-S-TP SM-151-S-TP 3-20<br />

SM-148-S SM-151-S-TP 3-20<br />

SM-225-S-TP SM-2E51-S-TP 3-20<br />

SM-233-S SM-2E51-S-TP 3-20<br />

SM-2E75-S-TP R-2E75-S-TP 3-22, 3-23<br />

TM-2E75-S-TP - -<br />

UHQM-1P40 V-140-TP 3-7, 3-9 to 10<br />

UM-140 V-140-TP 3-7, 3-9 to 10<br />

UM-1P30 VM-1P30-TP 3-8<br />

UM-2S40 V-2S40-TP 3-7, 3-9 to 11<br />

UM-2SP30 VM-2SP30-TP 3-8<br />

UQC-2S102 VC-2S102-TP 3-18, 3-19<br />

UQC-2S102-CW VC-2S102-TP 3-18, 3-19<br />

UQM-2S40 V-2S40-TP 3-7, 3-9 to 11<br />

UQM-2SP20 VM-2SP20-TP 3-27, 3-28<br />

US-110-TP VS-110-TP 3-13 to 3-17<br />

US-140 V-140-TP 3-7, 3-9 to 10<br />

US-2S110 V-S110-TP 3-16, 3-17<br />

US-2S60 VC-2S85-TP 3-13 to 3-17<br />

US-3P40 - -<br />

USC-2S200 VS-2S200-TP 3-18, 3-19<br />

USH-110 VS-110-TP 3-13 to 3-17<br />

USM-175-S VSM-175-S-TP 3-22, 3-23<br />

USM-2E40-S VSM-2E40-S-TP 3-21<br />

USM-2E75-S V-2E75-S-TP 3-22, 3-23<br />

V-2Q18-4P-TP-BLS - -<br />

V-2Q18-4P-TP-W - -<br />

V-2Q26-4P-TP-BLS - -<br />

V-2Q26-4P-TP-W - -<br />

V-2S86-TP ICN-2S86 1-65<br />

VADM-2E75-S V-2E75-S-TP 3-22, 3-23<br />

VC-160-(FO or RO) - -<br />

VC-160-TP VS-110-TP 3-13 to 3-17<br />

VC-1P40-TP - -<br />

VC-2S102-RO VC-2S102-FO 3-39<br />

VC-2S200-RO VC-2S200-FO 3-39<br />

VC-2SP40-TP - -<br />

VHQM-1P40 V-140-TP 3-7, 3-9 to 10<br />

VK-134-TP - -<br />

VK-2S40-TP VK-2S34-TP 1-68<br />

8-35<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDEX – FLUORESCENT BALLASTS<br />

DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />

Electromagnetic Fluorescent<br />

Discontinued<br />

Catalog<br />

Number<br />

Current<br />

Catalog<br />

Number<br />

Page<br />

No.<br />

VK-3S34-TP - -<br />

VM-140-TP V-140-TP 3-7, 3-9 to 10<br />

VM-2S40-TP V-2S40-TP 3-7, 3-9, 3-11<br />

VM-2SP15 VM-2SP20-TP 3-27, 3-28<br />

VQB-2S102 VC-2S102-TP 3-18, 3-19<br />

VQC-1100-CW - -<br />

VQC-2S100-CW - -<br />

VQC-2S102-(FO or RO) VC-2S102-FO 3-39<br />

VQC-2S102-CW VC-2S102-TP 3-18, 3-19<br />

VQM-2S40-TP V-2S40-TP 3-7, 3-9 to 11<br />

VS-110-(FO or RO) - -<br />

VS-140-TP V-140-TP 3-7, 3-9, 3-10<br />

VS-160-TP VS-110-TP 3-13 to 3-17<br />

VS-2S110-(FO or RO) VC-2S110-FO 3-38<br />

VS-2S110-TP V-2S110-TP 3-16, 3-17<br />

VS-2S200-RO VS-2S200-FO 3-39<br />

VS-2S40-TP V-2S40-TP 3-7, 3-9-3-11<br />

VS-2S60-TP VC-2S85-TP 3-13 to 3-17<br />

VS-2S85 VC-2S85-TP 3-13 to 3-17<br />

VS-2S85-(FO or RO) - -<br />

VS-3P40 - -<br />

VSH-240 - -<br />

VSH-240-S VSM-2E40-S-TP 3-21<br />

VSH-275-S-TP VC-2E75-S-TP 3-22, 3-23<br />

VSH-285 - -<br />

VSH-2E75-S V-2E75-S-TP 3-22, 3-23<br />

VSHM-125-S - -<br />

VSHM-140 V-140-TP 3-7, 3-9 to 10<br />

VSL-108-F-TP - -<br />

VSM-140-S - -<br />

VSM-225-S - -<br />

VSM-2E75-S-TP V-2E75-S-TP 3-22, 3-23<br />

XHQM-1P40-TP X-140-TP 6-3, 6-4<br />

XT-2E57-S-TP - -<br />

YQC-2S102-TP - -<br />

YSC-2S200-TP - -<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-36


INDEX – FLUORESCENT BALLASTS<br />

REFERENCE<br />

MATERIALS<br />

DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />

High Frequency <strong>Electronic</strong> Fluorescent<br />

Discontinued<br />

Catalog<br />

Number<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

GDC-132-TP …. ….<br />

GDC-140-TP …. ….<br />

GDC-2S32-TP …. ….<br />

GDC-2S40-TP …. ….<br />

GIC-132-TP GEL-2P32-LW 1-45, 49, 54, 55, 59<br />

GIC-140-TP …. ….<br />

GIC-2S32-TP GEL-2P32-SC 1-45, 48, 49, 54,<br />

55, 58, 59<br />

GIC-2S40-TP GEL-2S40-RH-TP 1-66, 1-67<br />

IZT-1T42-M2-BS* IZT-2S26-M5-BS 2-12<br />

IZT-1T42-M2-LD* IZT-2S26-M5-LD 2-12<br />

IZT-2Q26-M2-BS* IZT-2S26-M5-BS 2-12<br />

IZT-2Q26-M2-LD* IZT-2S26-M5-LD 2-12<br />

IZT-2T42-M3-BS* IZT-2T42-M5-BS 2-12<br />

IZT-2T42-M3-LD* IZT-2T42-M5-LD 2-12<br />

RCN-132-MC ICN-132-MC 1-41, 1-44, 1-54, 1-58<br />

RCN-1P32 ICN-1P32-SC 1-44, 1-48, 1-54, 1-58<br />

RCN-1P32-SC ICN-1P32-SC 1-44, 1-48, 1-54, 1-58<br />

RCN-1S28* ICN-2S28 1-41<br />

RCN-1S40-SC REL-1S40-SC 1-66, 1-67<br />

RCN-2M32-MC ICN-2M32-MC 1-41, 45, 49, 55, 59<br />

RCN-2P32 ICN-2P32-SC 1-44, 45, 48, 49,<br />

54, 55, 58, 1-59, 62<br />

RCN-2P32-LW ICN-2P32-LW-SC 1-44, 45, 48, 49,<br />

54, 55, 59, 62<br />

RCN-2P32-SC ICN-2P32-SC 1-44, 45, 48, 49,<br />

54, 1-55, 58, 59, 62<br />

RCN-2P54-SC ICN-2S54 1-34, 36, 37,<br />

42, 43, 6-6<br />

RCN-2S28* ICN-2S28 1-41<br />

RCN-2S32-LW ICN-2P32-LW-SC 1-44, 45, 48, 49,<br />

54, 55, 59, 62<br />

RCN-2S40 REL-2S40-SC 1-66, 1-67<br />

RCN-2S40-SC REL-2S40-SC 1-66, 1-67<br />

RCN-2S86 ICN-2S86 1-65<br />

RCN-3P32 ICN-3P32-SC 1-45, 46, 49, 50,<br />

55, 56, 59, 60, 62<br />

RCN-3P32-LW-SC ICN-3P32-LW-SC 1-45, 46, 49, 50,<br />

55, 56, 59, 60, 62<br />

RCN-3P32-SC ICN-3P32-SC 1-45, 46, 49, 50,<br />

55, 56, 59, 60, 62<br />

RCN-4P32 ICN-4P32-SC 1-46, 47, 50, 51,<br />

56, 57, 60, 61, 63<br />

RCN-4P32-LW-SC ICN-4P32-LW-SC 1-46, 47, 50, 51,<br />

56, 57, 60, 61, 63<br />

RCN-4P32-SC ICN-4P32-SC 1-46, 47, 50, 51,<br />

56, 57, 60, 61, 63<br />

RDC-132-TP IZT-132-SC 2-15, 2-16<br />

RDC-140-TP …. ….<br />

RDC-2BS40-TP IZT-2TTS40-SC 2-13<br />

RDC-2S32-TP IZT-2S32-SC 2-15, 2-16<br />

RDC-2S40-TP …. ….<br />

RDC-3S32-TP IZT-3S32-SC 2-15, 2-16<br />

RDC-3S40-TP …. ….<br />

REL-1P32-RH-TP REL-1P32-SC 1-44, 48, 54, 58<br />

REL-1S32-RH-TP RCN-1S32-SC 1-44, 48, 54, 58<br />

REL-1S40-RH-TP REL-1S40-SC 1-66, 1-67<br />

REL-1S40-TP REL-1S40-SC 1-66, 1-67<br />

REL-1T32 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />

REL-1T42 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />

REL-2P32-HL-RH-TP REL-2P32-HL-SC 1-45, 48, 49, 54,<br />

55, 58, 59, 62<br />

REL-2P32-LW-RH-TP REL-2P32-LW-SC 1-45, 49, 54, 55,<br />

58, 59, 62<br />

REL-2P32-RH-TP REL-2P32-SC 1-45, 48, 49, 54,<br />

55, 58, 59, 6-6<br />

REL-2P50-SC …. ….<br />

REL-2P59-HL …. ….<br />

REL-2P75-S-RH-TP REL-2P60-S 1-68<br />

REL-2P75-S-TP REL-2P60-S 1-68<br />

REL-2Q18 ICF-2S18-H1-LD 1-27, 30, 38<br />

REL-2Q26 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />

REL-2S32-LW-RH-TP REL-2P32-LW-SC 1-45, 49, 54, 55,<br />

58, 59, 62<br />

REL-2S32-RH-TP RCN-2S32-SC 1-45, 49, 55, 59<br />

REL-2S40-RH-TP REL-2S40-SC 1-66, 1-67<br />

REL-2S40-TP REL-2S40-SC 1-66, 1-67<br />

REL-3P32-HL REL-3P32-HL-SC 1-46, 49, 50, 55,<br />

56, 59, 60, 62<br />

REL-3P32-LW-RH-TP REL-3P32-LW-SC 1-46, 49, 50, 55,<br />

56, 59, 60, 62<br />

REL-3P32-RH-TP REL-3P32-SC 1-46, 49, 50, 55,<br />

High Frequency <strong>Electronic</strong> Fluorescent<br />

Discontinued<br />

Catalog<br />

Number<br />

* These ballasts will be phased out during 2004 and their replacements will be available accordingly.<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

56, 59, 60, 62, 6-6<br />

REL-3P32-TP REL-3P32-SC 1-46, 49, 50, 55,<br />

56, 59, 60, 62, 6-6<br />

REL-3S32-LW-RH-TP REL-3P32-LW-SC 1-46, 49, 50, 55,<br />

56, 59, 60, 62<br />

REL-3S32-RH-TP RCN-3S32-SC 1-46, 50, 56, 60<br />

REL-3S40-TP REL-3S40-RH-TP 1-66, 1-67<br />

REL-4P32 REL-4P32-SC 1-47, 50, 51, 56,<br />

57, 60, 61, 63, 6-6<br />

REL-4P32-2LS - -<br />

REL-4P32-LW-RH-TP REL-4P32-LW-SC 1-46, 47, 50, 51,<br />

56, 57, 60, 61, 63<br />

REL-4P32-RH-TP REL-4P32-SC 1-47, 50, 51, 56,<br />

57, 60, 61, 63, 6-6<br />

REL-4P32-TP REL-4P32-SC 1-47, 50, 51, 56,<br />

57, 60, 61, 63, 6-6<br />

REZ-132 REZ-132-SC 2-10<br />

REZ-1T32 REZ-1T42-M2-LD-K 2-7<br />

REZ-1T42 REZ-1T42-M2-LD-K 2-7<br />

REZ-1TTS40 REZ-1TTS40-SC 2-8<br />

REZ-2Q26 REZ-2Q26-M2-LD-K 2-7<br />

REZ-2S32 REZ-2S32-SC 2-10<br />

REZ-2TTS40 REZ-2TTS40-SC 2-8<br />

REZ-3S32 REZ-3S32-SC 2-10<br />

REZ-C1200-A …. ….<br />

REZ-C500-1 …. ….<br />

RIC-132 IIC-132-SC 1-44, 48, 54, 58<br />

RIC-132-TP IIC-132-SC 1-44, 48, 54, 58<br />

RIC-140-TP REL-1S40-SC 1-66, 1-67<br />

RIC-2S32 IIC-2S32-SC 1-45, 49, 55, 59<br />

RIC-2S32-TP IIC-2S32-SC 1-45, 49, 55, 59<br />

RIC-2S40-TP REL-2S40-SC 1-66, 1-67<br />

RIC-3S32 IIC-2S32-SC 1-45, 49, 55, 59<br />

RIC-3S32-TP IIC-2S32-SC 1-45, 49, 55, 59<br />

RIC-3S40-TP REL-3S40-RH-TP 1-66, 1-67<br />

RZT-132 IZT-132-SC 2-15, 2-16<br />

RZT-1TTS40 RZT-1TTS40-SC 2-8<br />

RZT-2S32 IZT-2S32-SC 2-15, 2-16<br />

RZT-2TTS40 IZT-2TTS40-SC 2-13<br />

RZT-3S32* IZT-3S32-SC 2-15, 2-16<br />

VCN-132-MC ICN-132-MC 1-41, 44, 54, 58<br />

VCN-1P32 ICN-1P32-SC 1-44, 48, 54, 58<br />

VCN-1P32-SC ICN-1P32-SC 1-44, 48, 54, 58<br />

VCN-1S28* ICN-2S28 1-41<br />

VCN-1S40-SC VEL-1S40-SC 1-66, 1-67<br />

VCN-2M32-MC ICN-2M32-MC 1-41, 45, 49, 55, 59<br />

VCN-2P32 ICN-2P32-SC 1-44, 45, 48, 49,<br />

54, 55, 58, 59, 62<br />

VCN-2P32-LW ICN-2P32-LW-SC 1-44, 45, 48, 49,<br />

54, 55, 58, 59, 62<br />

VCN-2P32-SC ICN-2P32-SC 1-44, 45, 48, 49,<br />

54, 55, 58, 59, 62<br />

VCN-2P54-SC ICN-2S54 1-34, 36, 37,<br />

42, 43, 6-6<br />

VCN-2S28* ICN-2S28 1-41<br />

VCN-2S32-LW ICN-2P32-LW-SC 1-44, 45, 48, 49,<br />

54, 55, 58, 59, 62<br />

VCN-2S40 REL-2S40-SC 1-66, 1-67<br />

VCN-2S40-SC VEL-2S40-SC 1-66, 1-67<br />

VCN-2S86 ICN-2S86 1-65<br />

VCN-3P32 ICN-3P32-SC 1-45, 46, 49, 50,<br />

55, 56, 59, 60, 62<br />

VCN-3P32-LW-SC ICN-3P32-LW-SC 1-45, 46, 49, 50,<br />

55, 56, 59, 60, 62<br />

VCN-3P32-SC ICN-3P32-SC 1-45, 46, 49, 50,<br />

55, 56, 59, 60, 62<br />

VCN-4P32 ICN-4P32-SC 1-46, 47, 50, 51,<br />

56, 57, 60, 61, 63<br />

VCN-4P32 VCN-4P32-SC 1-47, 51, 57, 61<br />

VCN-4P32-LW-SC ICN-4P32-LW-SC 1-46, 47, 50, 51,<br />

56, 57, 60, 61, 63<br />

VCN-4P32-SC ICN-4P32-SC 1-46, 47, 50, 51,<br />

56, 57, 60, 61, 63<br />

VDC-132-TP IZT-132-SC 2-15, 2-16<br />

VDC-140-TP …. ….<br />

VDC-2BS40-TP IZT2TTS40 2-13<br />

VDC-2S32-TP IZT-2S32-SC 2-15, 2-16<br />

VDC2S40-TP …. ….<br />

VDC-3S32-TP IZT-3S32 2-15, 2-16<br />

VDC-3S40-TP …. ….<br />

VEL-175-S-TP VEL-2P75-S 1-68<br />

VEL-1P32-RH-TP VEL-1P32-SC 1-44, 48, 54, 58<br />

VEL-1S32-RH-TP VCN-1S32-SC 1-44, 48, 54, 58<br />

Note: In some cases, replacement may have different dimensions, specifications, starting method, lamps<br />

supported or wiring configurations. Technical specifications of the replacement should be evaluated for<br />

intended application.<br />

High Frequency <strong>Electronic</strong> Fluorescent<br />

Discontinued<br />

Catalog<br />

Number<br />

Discontinued<br />

Catalog<br />

Number<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

VEL-1S40-RH-TP VEL-1S40-SC 1-66, 1-67<br />

VEL-1S40-TP VEL-1S40-SC 1-66, 1-67<br />

VEL-1T32 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />

VEL-1T42 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />

VEL-2E75-S-TP VEL-2P75-S 1-68<br />

VEL-2P32-HL-RH-TP VEL-2P32-HL-SC 1-45, 48, 49, 54,<br />

55, 58, 59, 62<br />

VEL-2P32-LW-RH-TP VEL-2P32-LW-SC 1-45, 49, 54, 55,<br />

58, 59, 62<br />

VEL-2P32-RH-TP VEL-2P32-SC 1-45, 48, 49, 54,<br />

55, 58, 59,<br />

VEL-2P50-SC …. ….<br />

VEL-2P59-HL - -<br />

VEL-2Q18 ICF-2S18-H1-LD 1-27, 1-30, 1-38<br />

VEL-2Q26 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />

VEL-2S32-LW-RH-TP VEL-2P32-LW.SC 1-45, 49, 54, 55,<br />

58, 59, 62<br />

VEL-2S32-RH-TP VCN-2S32-SC 1-45, 1-49, 1-55<br />

1-59<br />

VEL-2S40-RH-TP VEL-2S40-SC 1-66, 1-67<br />

VEL-2S40-TP VEL-2S40-SC 1-66, 1-67<br />

VEL-3P32-HL VEL-3P32-HL-SC 1-46, 49, 50, 55,<br />

56, 59, 60, 62<br />

VEL-3P32-LW-RH-TP VEL-3P32-LW-SC 1-45, 46, 49, 50,<br />

55, 56, 59, 60, 62<br />

VEL-3P32-RH-TP VEL-3P32-SC 1-46, 49, 50, 55,<br />

56, 59, 60, 62<br />

VEL-3P32-TP VEL-3P32-SC 1-46, 49, 50, 55,<br />

56, 59, 60, 62<br />

VEL-3S32-LW-RH-TP VEL-3P32-LW-SC 1-45, 46, 49, 50,<br />

55, 56, 59, 60, 62<br />

VEL-3S32-RH-TP VCN-3S32-SC 1-46, 50, 56, 60<br />

VEL-3S40-TP VEL-3S40-RH-TP 1-66, 1-67<br />

VEL-4P32-2LS - -<br />

VEL-4P32-LW-RH-TP VEL-4P32-LW-SC 1-46, 47, 50, 51,<br />

56, 57, 60, 61, 63<br />

VEL-4P32-RH-TP VEL-4P32-SC 1-47, 50, 51, 56,<br />

57, 60, 61, 63<br />

VEL-4P32-TP VEL-4P32-SC 1-47, 50, 51, 56,<br />

57, 60, 61, 63<br />

VEZ-132 VEZ-132-SC 2-10<br />

VEZ-1T32 VEZ-1T42-M2-LD-K 2-7<br />

VEZ-1T42 VEZ-1T42-M2-LD-K 2-7<br />

VEZ-1TTS40 VEZ-1TTS40-SC 2-8<br />

VEZ-2Q26 VEZ-2Q26-M2-LD-K 2-7<br />

VEZ-2S32 VEZ-2S32-SC 2-10<br />

VEZ-2TTS40 VEZ-2TTS40-SC 2-8<br />

VEZ-3S32 VEZ-2S32-SC 2-10<br />

VEZ-C1200-A …. ….<br />

VEZ-C500-1 …. ….<br />

VIC-132 IIC-132-SC 1-44, 48, 54, 58<br />

VIC-132-TP IIC-132-SC 1-44, 48, 54, 58<br />

VIC-140-TP VEL-1S40-SC 1-66, 1-67<br />

VIC-2S32 IIC-2S32-SC 1-45, 49, 55, 59<br />

VIC-2S32-TP IIC-2S32-SC 1-45, 49, 55, 59<br />

VIC-2S40-TP VEL-2S40-SC 1-66, 1-67<br />

VIC-3S32 IIC-2S32-SC 1-45, 49, 55, 59<br />

VIC-3S32-TP IIC-2S32-SC 1-45, 49, 55, 59<br />

VIC-3S40-TP VEL-3S40-RH-TP 1-66, 1-67<br />

VZT-132 IZT-132-SC 2-15, 2-16<br />

VZT-1TTS40-SC VZT-1TTS40-SC 2-8<br />

VZT-2S32 IZT-2S32-SC 2-15, 2-16<br />

VZT-2TTS40-SC IZT-2TTS40-SC 2-13<br />

VZT-3S32* IZT-3S32-SC 2-15, 2-16<br />

VZT-4S32-4 IZT-4S32 2-15, 2-16<br />

VZT-4S32-8 IZT-4S32 2-15, 2-16<br />

Low Frequency <strong>Electronic</strong> Fluorescent<br />

Page<br />

No.<br />

GK-2S110-TP … ….<br />

RK-134-TP …. ….<br />

RK-2S110-TP …. ….<br />

RK-2S40-TP RK-2S34-TP 1-67<br />

RK-3S34-TP …. ….<br />

VK-134-TP …. ….<br />

VK-2S40-TP VK-2S34-TP 1-67<br />

8-37<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDEX – HID BALLASTS<br />

DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />

HID HID HID<br />

Obsolete<br />

Catalog<br />

Numbers<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

Alternate<br />

Quadri-volt<br />

120/208/240/277V<br />

71A0201 71A0280 5-46 ….<br />

71A0401-791 .... .... ....<br />

71A0410 71A0490 5-46 71A0490<br />

71A0430 71A0490 5-46 71A0490<br />

71A0440 71A04F0 5-46 ….<br />

71A0450 71A0490 5-46 71A0490<br />

71A04D0 71A0490/04F0 5-46 ….<br />

71A0540 71A05F0 5-47 ….<br />

71A0550 71A0590 5-47 71A0590<br />

71A0560 71A0590 5-47 71A0590<br />

71A05D0 71A0590/05F0 5-47 ….<br />

71A0740 71A07F0 5-47 ….<br />

71A0750 71A0790 5-47 71A0790<br />

71A0760 71A0790 5-47 71A0790<br />

71A07D0 71A0790/07F0 5-47 ….<br />

71A1500 71A1580 5-14 ....<br />

71A1510 .... .... ....<br />

71A1530 71A1580 5-14 ....<br />

71A1540 .... .... ....<br />

71A15R0 .... .... ....<br />

71A1810 .... .... ....<br />

71A1820 .... .... ....<br />

71A1830 71A1580(CWA)** 5-14 ....<br />

71A2020 .... .... ....<br />

71A20R0 .... .... ....<br />

71A2300 71A2303 5-14 ....<br />

71A2310 .... .... ....<br />

71A2320 .... .... ....<br />

71A2330 71A2080(CWA)** 5-14 ....<br />

71A2340 .... .... ....<br />

71A2500 71A2501 5-14 71A2571/91<br />

71A2502 71A2501 5-14 71A2571/91<br />

71A2510 71A2571/91 5-14 71A2571/91<br />

71A2512 71A2571/91 5-14 71A2571/91<br />

71A2520 .... .... 71A2571/91<br />

71A2522 .... .... 71A2571/91<br />

71A2530 71A2571/91 5-14 71A2571/91<br />

71A2531 71A2571/91 5-14 71A2571/91<br />

71A2532 71A2571/91 5-14 71A2571/91<br />

71A2540 71A2541 5-14 ....<br />

71A2542 71A2541 5-14 ....<br />

71A2551 .... .... 71A2571/91<br />

71A2561 .... .... 71A2571/91<br />

71A25D1 71A25A1<br />

5-14 71A2571/91<br />

(120/240/347V)<br />

(120/277/347V)<br />

71A25J1 .... .... ....<br />

71A25R1 71A25N1 5-15 ....<br />

71A2801 71A2800 5-14 ....<br />

71A2803 71A2800 5-14 ....<br />

71A2810 .... .... 71A2571/91(CWA)**<br />

71A2820 .... .... 71A2571/91(CWA)**<br />

71A2840 71A2541(CWA)** 5-14 ....<br />

71A29G0 .... .... ....<br />

71A3000 71A3002 5-15 71A3072/92<br />

71A3001 71A3002 5-15 71A3072/92<br />

71A3010 .... .... 71A3072/92<br />

71A3011 .... .... 71A3072/92<br />

71A3012 .... .... 71A3072/92<br />

71A3020 .... .... 71A3072/92<br />

71A3021 .... .... 71A3072/92<br />

71A3022 .... .... 71A3072/92<br />

71A3030 71A3072/92<br />

5-5,<br />

5-15<br />

71A3072/92<br />

Obsolete<br />

Catalog<br />

Numbers<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

71A3031 71A3072/92<br />

71A3032 71A3072/92<br />

Page<br />

No.<br />

5-5,<br />

5-15<br />

5-5,<br />

5-15<br />

Alternate<br />

Quadri-volt<br />

120/208/240/277V<br />

71A3072/92<br />

71A3072/92<br />

71A3040 71A3042 5-15 ....<br />

71A3041 71A3042 5-15 ....<br />

71A3052 .... .... 71A3072/92<br />

71A3062 .... .... 71A3072/92<br />

71A30J2 .... .... ....<br />

71A3140 71A3042 5-15 ....<br />

71A3150 .... .... 71A3072/92<br />

71A3320 .... .... 71A3072/92(CWA)**<br />

71A3330 71A3072/92(CWA)** 5-15 ....<br />

71A3340 71A3042(CWA)** 5-15 ....<br />

71A3500 71A3502 5-16 71A3572/92<br />

71A3501 71A3502 5-16 71A3572/92<br />

71A3510 .... .... 71A3572/92<br />

71A3520 .... .... 71A3572/92<br />

71A3521 .... .... 71A3572/92<br />

71A3522 .... .... 71A3572/92<br />

71A3530 .... .... 71A3572/92<br />

71A3531 .... .... 71A3572/92<br />

71A3532 .... .... 71A3572/92<br />

71A3540 71A3542 5-16 ....<br />

71A3541 71A3542 5-16 ....<br />

71A3552 71A3572/92 5-16 71A3572/92<br />

71A3562 71A3572/92 5-16 71A3572/92<br />

71A35J2 .... .... ....<br />

71A35R2 71A57N0 6-16 ....<br />

71A3640 71A3542 5-16 ....<br />

71A3650 .... .... 71A3572/92<br />

71A3800 71A3502(CWA)** 5-16 71A3572/92(CWA)**<br />

71A3810 .... .... 71A3572/92(CWA)**<br />

71A3820 .... .... 71A3572/92(CWA)**<br />

71A3825-791 .... .... ....<br />

71A3830 .... .... 71A3572/92(CWA)**<br />

71A3840 71A3542(CWA)** 5-16 ....<br />

71A4000 .... .... 71A4071/91<br />

71A4001 .... .... 71A4071/91<br />

71A4020 .... .... 71A4071/91<br />

71A4021 .... .... 71A4071/91<br />

71A4030 .... .... 71A4071/91<br />

71A4031 .... .... 71A4071/91<br />

71A4040 71A4041 5-17 ....<br />

71A4051 71A4071/91 5-17 71A4071/91<br />

71A4061 71A4071/91 5-17 71A4071/91<br />

71A40J1 .... .... ....<br />

71A40R1 71A60N1 6-16 ....<br />

71A4142 71A4041 5-17 71A4071/91<br />

71A4152 .... .... 71A4071/91<br />

71A4310 .... .... ....<br />

71A4320 .... .... ....<br />

71A4401 .... .... 71A4071/91(CWA)**<br />

71A4411 .... .... 71A4071/91(CWA)**<br />

71A4421 .... .... 71A4071/91(CWA)**<br />

71A4431 .... .... 71A4071/91(CWA)**<br />

71A4441 71A4041(CWA)** 5-17 71A4071/91(CWA)**<br />

71A5000 .... .... 71A5070/90<br />

71A5005 71A5005-P 5-18 ....<br />

71A5030* .... .... 71A5070/90<br />

71A5037 71A5037-P 5-18 ....<br />

71A5037-B 71A5037-BP 5-18 ....<br />

71A5050 .... .... 71A5070/90<br />

Obsolete<br />

Catalog<br />

Numbers<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

Alternate<br />

Quadri-volt<br />

120/208/240/277V<br />

71A5060 .... .... 71A5070/90<br />

71A5090 71A5070-001<br />

5-5,<br />

5-17<br />

71A5102 .... .... 71A5070/90<br />

71A5105 71A5105-P 5-18 ....<br />

71A5122 .... .... 71A5070/90<br />

71A5137 71A5137-P 5-18 ....<br />

71A5137-B 71A5137-BP 5-18 ....<br />

71A5142 71A5040 5-17 ....<br />

71A5205 71A5205-P 5-19 ....<br />

71A5227 (Reactor) .... .... 71A5292 (3x4 Core)<br />

71A5228 .... .... ....<br />

71A5229 (Reactor) .... .... 71A5292 (3x4 Core)<br />

71A5237 71A5237-P 5-19 ....<br />

71A5237-B 71A5237-BP 5-19 ....<br />

71A5288 .... .... ....<br />

71A5289<br />

.... .... 71A5292 (3x4 Core)<br />

(Reactor + Transformer)<br />

71A52C2 71A52A2 5-19 71A5292 (3x4 Core)<br />

71A5337 71A5337-P 5-20 ....<br />

71A5337-B 71A5337-BP 5-20 ....<br />

71A5338 .... .... ....<br />

71A5386 .... .... ....<br />

71A5387<br />

.... .... 71A5390 (3x4 Core)<br />

(Reactor + Transformer)<br />

71A5388 .... .... ....<br />

71A53C0 71A53A0 5-20 71A5390 (3x4 Core)<br />

71A5427 (Reactor) .... .... 71A5490 (3x4 Core)<br />

71A5428 (Reactor) .... .... 71A5490 (3x4 Core)<br />

71A5429 (Reactor) .... .... 71A5492 (3x4 Core)<br />

71A5437 71A5437-P 5-21 ....<br />

71A5437-B 71A5437-BP 5-21 ....<br />

71A5488<br />

.... .... 71A5490 (3x4 Core)<br />

(Reactor + Autotransformer)<br />

71A5489<br />

.... .... 71A5492 (3x4 Core)<br />

(Reactor + Autotransformer)<br />

71A5510 71A5570/90 5-22 71A5570/90<br />

71A5520 71A5570/90 5-22 71A5570/90<br />

71A5550 71A5570/90 5-22 71A5570/90<br />

71A5560 71A5570/90 5-22 71A5570/90<br />

71A5592 71A5593 5-22 71A5593<br />

71A55A2 71A55A3 5-22 ....<br />

71A55B0 71A55A0 5-22 ....<br />

71A55D0 71A55A0<br />

5-22 71A5570/90<br />

(120/240/347V)<br />

(120/240/347V)<br />

71A55G0 71A55H0 5-22 ....<br />

71A55J0 71A55H0 5-22 ....<br />

71A55R0 71A55N0 6-16 ....<br />

71A5710 71A5770/90 5-6 71A5770/90<br />

71A5711 71A5771/91<br />

5-6,<br />

5-24<br />

71A5771/91<br />

71A5720 71A5770/90 5-6 71A5770/90<br />

71A5721 71A5771/91<br />

5-6,<br />

5-24<br />

71A5771/91<br />

71A5750 .... .... 71A5770/90<br />

71A5760 .... .... 71A5770/90<br />

71A5793 71A5792 5-25 71A5792<br />

71A57A3 71A57A2 5-25 ....<br />

71A57D0 71A57A0<br />

5-24 71A5770/90<br />

(120/240/347V)<br />

(120/240/347V)<br />

71A57J0 71A55H0 5-22 ....<br />

71A57R0 71A57N0 6-16 ....<br />

71A5843-T 71A5842-T 5-26 ....<br />

* Availability limited to existing stocks.<br />

** The CWA ballasts offered as replacements are furnished with a capacitor which must be used in<br />

the ballast circuit as shown in the wiring diagram in this <strong>Atlas</strong>. The original ballast circuit in the<br />

lighting fixture may have been low or normal power factor, and therefore, no capacitor was used.<br />

If the CWA ballast with its capacitor does not fit in the fixture, contact <strong>Advance</strong> for assistance.<br />

<strong>Advance</strong> Replacement ballasts shown are functionally equivalent to listed obsolete ballasts.<br />

Dimensional differences can exist.<br />

Suffix “T” ballast catalog numbers indicate ballast is equipped with 120V output tap. Standard practice<br />

is to use 120V tap on quadri-volt ballast, where quadri-volt ballasts are available.<br />

Where no replacement ballast is shown, ballast has been discontinued and inventories are exhausted.<br />

Consult nearest <strong>Advance</strong> sales office for assistance.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-38


INDEX – HID BALLASTS<br />

DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />

HID HID HID<br />

Obsolete<br />

Catalog<br />

Numbers<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

Alternate<br />

Quadri-volt<br />

120/208/240/277V<br />

71A5893 71A5892 5-26 71A5892<br />

71A58A3 71A58A2 5-26 ....<br />

71A58N3 71A58N2 6-16 ....<br />

71A5942-T 71A5943-T 5-26 ....<br />

71A5992 71A5993 5-26 71A5993<br />

71A59A2 71A59A3 5-26 ....<br />

71A59N2 71A59N3 6-16 ....<br />

71A6000 71A6001 5-27 71A6071/91<br />

71A6010 71A6071/91<br />

5-6,<br />

5-27<br />

71A6071/91<br />

71A6011 71A6071/91<br />

5-6,<br />

5-27<br />

71A6071/91<br />

71A6020 71A6021 5-26 71A6071/91<br />

71A6021 71A6071/91<br />

5-6,<br />

5-27<br />

71A6071/91<br />

71A6030 71A6031 5-27 71A6071/91<br />

71A6040 71A6041 5-27 71A6071/91<br />

71A6043-T 71A6042-T 5-28 ....<br />

71A6061 71A6071/91<br />

5-6,<br />

5-27<br />

71A6071/91<br />

71A6084 (120/277V) 71A6004 (120V) 5-26 71A6034 (277V)<br />

71A6093 71A6092 5-28 71A6092<br />

71A60A3 71A60A2 5-28 ....<br />

71A60B1 71A60A1(120/277/347V) 5-27 ....<br />

71A60D1 71A60A1<br />

5-27 71A6071/91<br />

(120/240/347V)<br />

(120/277/347V)<br />

71A60J1 71A60H1 5-27 ....<br />

71A60N3 71A60N2 6-16 ....<br />

71A60R1 71A60N1 6-16 ....<br />

71A6300 (Series) 71A6382(ILO) 5-28 ....<br />

71A6310 (Series) .... .... ....<br />

71A6320 (Series) .... .... ....<br />

71A6330 (Series) 71A6382-001D(ILO) 5-6 ....<br />

71A6340 (Series) 71A6382-001D(ILO) 5-6 ....<br />

71A6342 71A6342-001D 5-6 ....<br />

71A6352 (120/240V) 71A6382-001D(120V) 5-6 ....<br />

71A6382 71A6382-001D 5-6 ....<br />

71A63J2 .... .... ....<br />

71A6500 71A6502 5-30 71A6572/92<br />

71A6501 71A6502 5-30 71A6572/92<br />

71A6510 71A6572/92 5-30 71A6572/92<br />

71A6511 71A6572/92 5-30 71A6572/92<br />

71A6512 71A6572/92 5-30 71A6572/92<br />

71A6520 71A6572/92 5-30 71A6572/92<br />

71A6521 71A6572/92 5-30 71A6572/92<br />

71A6522 71A6572/92 5-30 71A6572/92<br />

71A6530 71A6532 5-30 71A6572/92<br />

71A6531 71A6532 5-30 71A6572/92<br />

71A6540 71A6542 5-30 ....<br />

71A6541 71A6542 5-30 ....<br />

71A6551 71A6572/92 5-30 71A6572/92<br />

71A6561 71A6572/92 5-30 71A6572/92<br />

71A6571 71A6572 5-30 71A6572/92<br />

71A65B2 71A65A2(120/277/347V) 5-30 ....<br />

71A65D2(120/240/347V) 71A65A2 5-30 ....<br />

71A65E3 71A6593<br />

5-29 71A6593<br />

(120/240/347V)<br />

(120/240/347V)<br />

71A65F3<br />

(277/347/480V)<br />

71A65F3-T<br />

(347/480V/120T)<br />

5-29 ....<br />

71A65M6 .... .... ....<br />

71A65R2 71A65N2 6-16 ....<br />

71A6700 71A6702 5-31 71A6772/92<br />

Obsolete<br />

Catalog<br />

Numbers<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

Alternate<br />

Quadri-volt<br />

120/208/240/277V<br />

71A6701 71A6702 5-31 71A6772/92<br />

71A6710 71A6772/92<br />

5-6,<br />

5-31<br />

71A6772/92<br />

71A6711 71A6772/92<br />

5-6,<br />

5-31<br />

71A6772/92<br />

71A6712 71A6772/92<br />

5-6,<br />

5-31<br />

71A6772/92<br />

71A6720 71A6722/92 5-31 71A6772/92<br />

71A6721 71A6722/92 5-31 71A6772/92<br />

71A6722 71A6722/92 5-31 71A6772/92<br />

71A6730 71A6732 5-31 71A6772/92<br />

71A6731 71A6732 5-31 71A6772/92<br />

71A6740 71A6742 5-31 ....<br />

71A6771 71A6772<br />

5-6,<br />

5-31<br />

71A6772/92<br />

71A6791 71A6792 5-31 71A6772/92<br />

71A67D2 71A67A2<br />

5-31 71A6772/92<br />

(120/240/347V)<br />

(120/277/347V)<br />

71A68J0 .... .... ....<br />

71A7900 71A7950 5-35 ....<br />

71A7910* .... .... ....<br />

71A7920 71A7950 5-35 ....<br />

71A7956 71A79E6(120/208/240V) 5-35 ....<br />

71A7960 (240/480V) 71A7950 (120/240V) 5-35 71A7940*(480V)<br />

71A79D1 71A79A1<br />

(120/240/347V) (120/277/347)<br />

5-34 71A7971/91<br />

71A8000 71A8050/80 5-37 ....<br />

71A8030 71A8080 5-37 ....<br />

71A8056 71A80E6 (120/277/347) 5-37 ....<br />

71A8060(240/480V) .... .... 71A8040(480V)<br />

71A80D1<br />

(120/240/347V)<br />

71A80A1<br />

(120/277/347V)<br />

5-36 71A8071/91<br />

71A80R1 71A79N1,71A80N1 6-17 ....<br />

71A8106* .... .... 71A8176/96<br />

71A8111 .... .... 71A8176/96<br />

71A8116* .... .... 71A8176/96<br />

71A8130 71A8180 5-39 ....<br />

71A8131 71A8176/96<br />

5-7,<br />

5-38<br />

71A8176/96<br />

71A8136 71A8176/96<br />

5-7,<br />

5-38<br />

71A8176/96<br />

71A8141 .... .... ....<br />

71A8151 .... .... 71A8176/96<br />

71A8156 71A81E6(120/208/240V) 5-39 ....<br />

71A81D2 71A81A2<br />

5-38 71A8172/92<br />

(120/240/347V)<br />

(120/277/347V)<br />

71A81R2 71A81N2 6-17 ....<br />

71A8211 71A8271/91 5-41 71A8271/91<br />

71A8221 71A8271/91 5-41 71A8271/91<br />

71A8230 71A8280 5-41 ....<br />

71A8250 (120/240V) .... .... 71A8220 (240V)<br />

71A8256 71A82E6(120/208/240V) 5-41 ....<br />

71A8260 (240/480V) .... .... 71A8240 (480V)<br />

71A8294<br />

(120/208/240/277V)<br />

71A8280 (120/277V)<br />

71A8210 (208V)<br />

5-41 71A8220 (240V)<br />

71A82B1 71A82A1(120/277/347V) 5-41 ....<br />

71A82D1 71A82A1<br />

5-41 71A8271/91<br />

(120/240/347V)<br />

(120/277/347V)<br />

71A82R1 71A82N1 6-17 ....<br />

71A8311 .... .... 71A8371/91<br />

71A8321 .... .... 71A8371/91<br />

71A8331 .... .... 71A8371/91<br />

Obsolete<br />

Catalog<br />

Numbers<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

Alternate<br />

Quadri-volt<br />

120/208/240/277V<br />

71A8401 71A8403 5-43 71A8473/93<br />

71A8402 71A8403 5-43 71A8473/93<br />

71A8411 71A8473/93 5-43 71A8473/93<br />

71A8412 71A8473/93 5-43 71A8473/93<br />

71A8413 71A8473/93 5-43 71A8473/93<br />

71A8420 71A8450 5-43 ....<br />

71A8421 71A8473/93 5-43 71A8473/93<br />

71A8422 71A8473/93 5-43 71A8473/93<br />

71A8423 71A8473/93 5-43 71A8473/93<br />

71A8430 71A8480 5-43 ....<br />

71A8431 71A8433 5-43 71A8473/93<br />

71A8432 71A8433 5-43 71A8473/93<br />

71A8441 71A8443 5-43 ....<br />

71A8442 71A8443 5-43 ....<br />

71A8456 71A84E6(120/208/240V) 5-43 ....<br />

71A8471 .... .... 71A8473/93<br />

71A8472 .... .... 71A8473/93<br />

71A8482 .... .... 71A8473/93<br />

71A8484 71A8480 5-43 ....<br />

71A8491 .... .... 71A8473/93<br />

71A8492 .... .... 71A8473/93<br />

71A84D3 71A84A3<br />

5-43 71A8473/93<br />

(120/240/347V)<br />

(120/277/347V)<br />

71A84R2 71A84N3 6-17 ....<br />

71A8540 71A85F5 5-44 ....<br />

71A8590 71A85E5<br />

5-44<br />

71A85F5<br />

(120/208/240/277V) (120/208/240V) (277/347/480)<br />

71A85A3 .... .... ....<br />

71A8741 71A8743 5-45 ....<br />

71A8771 71A8773/93 5-45 71A8773/93<br />

71A8791 71A8773/93 5-45 71A8773/93<br />

71A87D3 71A87A3<br />

5-45 71A8773/93<br />

(120/240/347V)<br />

(120/277/347V)<br />

71A8900 .... .... 71A8970/90<br />

71A8930 .... .... 71A8970/90<br />

71A8931 .... .... 71A8991<br />

71A8984 (120/277V) 71A8954 (120V) 5-40 71A8970/90 (CWA)<br />

71A9068 .... .... 71A4071/91<br />

71A9073 .... .... 71A5070/90<br />

71A9074 71A5040 5-18 ....<br />

71A9082 .... .... 71A4071/91<br />

71A9114 .... .... ....<br />

71A9115 71A40R1<br />

5-9,<br />

5-17<br />

....<br />

71A9116 71A65N2 6-16 ....<br />

71A9124 .... .... 71A4071/91<br />

71A9127 .... .... 71A5070/90<br />

71A9135 .... .... 71A3072/92<br />

71A9136 .... .... 71A3072/92<br />

71A9137 .... .... 71A3072/92<br />

71A9138 71A3072/92<br />

5-5,<br />

5-15<br />

71A3072/92<br />

71A9139 71A3042 5-15 ....<br />

71A9189 71A0590 5-47 ....<br />

71A9192 71A0490 5-46 ....<br />

71A9209 71A5580 5-22 71A5570/90<br />

71A9212 71A6382-001D 5-6 ....<br />

71A9240 .... .... 71A3572/92<br />

71A9242 .... .... 71A5570/90<br />

71A9243 71A5540 5-22 ....<br />

71A9263 .... .... 71A3572/92<br />

71A9278 71A25N1 6-15 ....<br />

REFERENCE<br />

MATERIALS<br />

* Availability limited to existing stocks.<br />

** The CWA ballasts offered as replacements are furnished with a capacitor which must be used in<br />

the ballast circuit as shown in the wiring diagram in this <strong>Atlas</strong>. The original ballast circuit in the<br />

lighting fixture may have been low or normal power factor, and therefore, no capacitor was used.<br />

If the CWA ballast with its capacitor does not fit in the fixture, contact <strong>Advance</strong> for assistance.<br />

<strong>Advance</strong> Replacement ballasts shown are functionally equivalent to listed obsolete ballasts. Dimensional<br />

differences can exist.<br />

Suffix “T” ballast catalog numbers indicate ballast is equipped with 120V output tap. Standard practice<br />

is to use 120V tap on quadri-volt ballast, where quadri-volt ballasts are available.<br />

Where no replacement ballast is shown, ballast has been discontinued and inventories are exhausted.<br />

Consult nearest <strong>Advance</strong> sales office for assistance.<br />

8-39<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


INDEX – HID BALLASTS<br />

DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />

HID HID HID<br />

Obsolete<br />

Catalog<br />

Numbers<br />

71A9279<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

71A35R2<br />

Page<br />

No.<br />

5-11,<br />

5-16<br />

Alternate<br />

Quadri-volt<br />

120/208/240/277V<br />

71A9280 71A55N0 6-16 71A9281<br />

71A9282 71A65N2 6-16 ....<br />

71A9301 71A07F0 5-47 ....<br />

71A9302 .... .... 71A6071/91<br />

71A9303 .... .... 71A6071/91<br />

71A9305 .... .... 71A6572/92<br />

71A9306 .... .... 71A4071/91<br />

71A9312 .... .... 71A4071/91<br />

71A9313 .... .... 71A4071/91<br />

71A9314 .... .... 71A4071/91<br />

71A9315 .... .... 71A4071/91<br />

71A9316 71A4041 5-17 ....<br />

71A9317 71A0790 5-47 71A0750<br />

71A9318 71A0790 5-47 71A0760<br />

71A9319 .... .... 71A4071/91<br />

71A9326 71A07F0 5-47 ....<br />

71A9327 71A04F0 5-46 ....<br />

71A9328 71A05F0 5-47 ....<br />

71A9331 .... .... 71A2571/91<br />

71A9332 .... .... 71A2571/91<br />

71A9334 .... .... 71A3572/92<br />

71A9335 .... .... ....<br />

71A9341 71A0590 5-47 71A0560<br />

71A9352 71A3002 (CWA)** 5-15 71A3072/92<br />

71A9355 71A0790 5-47 71A0760<br />

71A9356 71A0590 5-47 71A0560<br />

71A9357 71A0490 5-46 71A0410<br />

71A9359 71A0490 5-46 71A0430<br />

71A9366 71A4041(CWA)** 5-17 ....<br />

71A9377* .... .... ....<br />

71A9378* .... .... ....<br />

71A9416 71A3592 5-16 71A3572/92<br />

71A9417 71A3072<br />

5-5,<br />

5-15<br />

71A3572/92<br />

71A9418 71A3092 5-15 71A3572/92<br />

71A9424 71A65A2 5-30 ....<br />

71A9426 71A57N0 6-16 ....<br />

71A9429 71A82N1 6-17 ....<br />

71A9430 71A84N3 6-17 ....<br />

71A9432 (240/480V) 71A4041(480V) 5-17 71A4071/91(240V)<br />

71A9437 (240/480V) 71A5040 (480V) 5-18 71A5070/90 (240V)<br />

71A9441 71A87R3 6-17 ....<br />

71A9445 71A0450 5-46 ....<br />

71A9446 .... .... ....<br />

71A9449 .... .... ....<br />

71A9451 71A82H1 5-41 ....<br />

71A9452 71A84H3 5-43 ....<br />

71A9462 71A81R6 6-17 ....<br />

71A9465 71A67R2 6-16 ....<br />

71A9467 71A0201 5-49 ....<br />

71A9468 71A4071/91 5-17 71A4071/91<br />

71A9469 71A4091 5-17 71A4071/91<br />

71A9470 .... .... ....<br />

71A9471 .... .... ....<br />

71A9473 71A25N1 6-15 ....<br />

71A9474 71A29R0 6-15 ....<br />

71A9475 .... .... ....<br />

71A9476 71A35R2 5-49 ....<br />

71A9477 71A40R1 5-49 ....<br />

71A9478 71A65N2 6-16 ....<br />

....<br />

Obsolete<br />

Catalog<br />

Numbers<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

Alternate<br />

Quadri-volt<br />

120/208/240/277V<br />

71A9479 71A55N0 6-16 ....<br />

71A9480 71A57N0 6-16 ....<br />

71A9481 71A60N1 6-16 ....<br />

71A9482 71A65N2 6-16 ....<br />

71A9483 71A67R2 6-16 ....<br />

71A9484 71A79N1 6-17 ....<br />

71A9485 71A80N1 6-17 ....<br />

71A9486 71A81N2 6-17 ....<br />

71A9487 71A81R6 6-17 ....<br />

71A9489 71A82N1 6-17 ....<br />

71A9491 71A84N3 6-17 ....<br />

71A9492 70A87R3 .... ....<br />

71A9494 71A78R1 6-17 ....<br />

71A9502 (240/480V) 71A8241(480V) 5-41 71A8271/91 (240V)<br />

71A9519 .... .... ....<br />

71A9520 71A3542 (CWA)** 5-16 ....<br />

71A9521 71A4041(CWA)** 5-17 ....<br />

71A9522 71A7941 5-34 ....<br />

71A9523 71A8041 5-36 ....<br />

71A9524 .... .... ....<br />

71A9525 .... .... ....<br />

71A9526 71A07F0 5-47 ....<br />

71A9530 .... .... 71A4071/91<br />

71A9532 .... .... ....<br />

71A9533 .... .... ....<br />

71A9534 .... .... ....<br />

71A9545 71A8107 5-38 ....<br />

71A9546 71A8007 5-36 ....<br />

71A9547 71A7907 5-34 ....<br />

71A9590 .... .... 71A8176/96<br />

71A9597 .... .... ....<br />

71A9646 71A0280 5-46 ....<br />

71A9696 .... .... ....<br />

71A9720 71A60H1 5-27 ....<br />

71A9722 71A55H0 5-22 ....<br />

71A9733 .... .... ....<br />

71A9734 71A79J1 5-34 ....<br />

71A9735 71A80J1 5-36 ....<br />

71A9737 71A87J3 5-45 ....<br />

71A9740-2T .... .... ....<br />

71A9745-2T .... .... ....<br />

71A9748* .... .... ....<br />

71A9761 71A65J2 5-30 ....<br />

71A9775 .... .... ....<br />

71A9784 71A57H0 5-24 ....<br />

71A9787 .... .... ....<br />

71A9789 71A80J1 5-36 ....<br />

71A9791 .... .... ....<br />

71A980 (120/277V) 71A7950 (120/240V) 5-35 71A7930 (277V)<br />

71A9808* .... .... ....<br />

71A9814 .... .... ....<br />

72C9156 72C4083-N-P 5-56 ....<br />

72C9159 72C4083-N-P 5-56 ....<br />

72C9160 72C3584-N-P 5-56 ....<br />

72C9163 72C3584-N-P 5-56 ....<br />

72C9164 72C3084-N-P 5-56 ....<br />

72C9167 72C3084-N-P 5-56 ....<br />

72C9168 72C2584-N-P 5-56 ....<br />

72C9171 72C2584-N-P 5-56 ....<br />

72C9221 72C2584-N-P 5-56 ....<br />

72C9222 72C3084-N-P 5-56 ....<br />

72C9223 72C3584-N-P 5-56 ....<br />

Obsolete<br />

Catalog<br />

Numbers<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

Alternate<br />

Quadri-volt<br />

120/208/240/277V<br />

72C9224 72C4083-N-P 5-56 ....<br />

72E5005-NP IMH50ALF 4-5 ....<br />

72E5005-NP-BLS IMH50ABLS 4-5 ....<br />

73B5580 73B5590 5-61 73B5590<br />

73B5780 73B5790 5-62 73B5790<br />

73B6081 73B6091 5-62 73B6091<br />

73B7705 .... .... ....<br />

74P1831-011 .... .... ....<br />

74P2321-011 .... .... ....<br />

78E3542-001 .... ....<br />

78E4300 (Series) .... .... ....<br />

78E4310 (Series) .... .... ....<br />

78E4320 (ILO) .... .... ....<br />

78E4330 (Series) .... .... ....<br />

78E4340 (Series) .... .... ....<br />

78E5040-001 .... .... ....<br />

78E5090-001 .... .... ....<br />

78E6300 (Series) .... .... ....<br />

78E6310 (Series) .... .... ....<br />

78E6320 (Series) .... .... ....<br />

78E6330 (Series) .... .... ....<br />

78E6340 (Series) .... .... ....<br />

78E6351* .... .... ....<br />

78E8391 .... .... ....<br />

78E8492 78E8493 5-68 ....<br />

799501-001 .... .... ....<br />

79W3140 .... .... ....<br />

79W3150 79W3092 5-69 ....<br />

79W3640 79W3542 5-69 ....<br />

79W3650 79W3592 5-69 ....<br />

79W4300 (Series) 79W6351(ILO) 5-70 ....<br />

79W4320 (Series) 79W6351(ILO) 5-70 ....<br />

79W4330 (Series) .... .... ....<br />

79W4340 (Series) 79W6341(ILO) 5-70 ....<br />

79W6300 (Series) 79W6351(ILO) 5-70 ....<br />

79W6310 (Series) .... .... ....<br />

79W6320 (Series) 79W6351(ILO) 5-70 ....<br />

79W6330 (Series) .... .... ....<br />

79W6340 (Series) 79W6341(ILO) 5-70 ....<br />

79W6381* .... .... ....<br />

79W6541 79W6542 5-70 ....<br />

79W6591 79W6592 5-70 ....<br />

79W8463 (240/480V) 79W8443 (480V) 5-71 79W8493 (240V)<br />

79W8492 79W8493 5-71 ....<br />

79W9256 79W6351 5-70 ....<br />

79W9499* .... .... ....<br />

79W9500 (240/480V) 79W8192 (240V) 5-71 ....<br />

79W9501* .... .... ....<br />

79W9502 (240/480V) 79W8241 (480V) 5-71 79W8291 (240V)<br />

79W9503 (240/480V) 79W8443 (480V) 5-71 79W8493 (240V)<br />

* Availability limited to existing stocks.<br />

** The CWA ballasts offered as replacements are furnished with a capacitor which must be used in<br />

the ballast circuit as shown in the wiring diagram in this <strong>Atlas</strong>. The original ballast circuit in the<br />

lighting fixture may have been low or normal power factor, and therefore, no capacitor was used.<br />

If the CWA ballast with its capacitor does not fit in the fixture, contact <strong>Advance</strong> for assistance.<br />

<strong>Advance</strong> Replacement ballasts shown are functionally equivalent to listed obsolete ballasts. Dimensional<br />

differences can exist.<br />

Suffix “T” ballast catalog numbers indicate ballast is equipped with 120V output tap. Standard practice<br />

is to use 120V tap on quadri-volt ballast, where quadri-volt ballasts are available.<br />

Where no replacement ballast is shown, ballast has been discontinued and inventories are exhausted.<br />

Consult nearest <strong>Advance</strong> sales office for assistance.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-40


INDEX – HID BALLASTS<br />

DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />

IGNITORS<br />

Obsolete<br />

Catalog<br />

Numbers<br />

Suggested<br />

Replacement<br />

Catalog Number<br />

Page<br />

No.<br />

LI500 LI501-H4 5-53, 54 ....<br />

LI501-A LI501-H4 5-51,53,54,55 ....<br />

LI501-B5 LI501-H4 5-53, 54 ....<br />

LI501-E LI501-J4 5-53 ....<br />

LI505-H4 (Cut-off) LI501-H4 (Std.) 5-53 ....<br />

LI520-H5 LI522-H5 5-51 ....<br />

LI521-H5 LI522-H5 5-51 ....<br />

LI525-H6 (Cut-off) LI522-H5 (Std.) 5-51 ....<br />

LI530-H5 LI533-H4 5-51 ....<br />

LI531-H5 LI533-H4 5-51 ....<br />

LI532-H4 LI533-H4 5-51 ....<br />

LI533-H4A LI533-H4 5-51 ....<br />

LI540-H4 Consult Factory for Availability<br />

LI550 LI551-H4 5-53 ....<br />

LI551-B5 LI551-H4 5-53 ....<br />

LI551-RS .... .... ....<br />

LI555-H4 (Cut-off) LI551-H4 (Std.) 5-53 ....<br />

LI560-H5 LI561-H5 5-51 ....<br />

LI570 LI571-H5 5-51, 53, 54 ....<br />

Alternate<br />

Quadri-volt<br />

120/208/240/277V<br />

* Availability limited to existing stocks.<br />

** The CWA ballasts offered as replacements are furnished with a capacitor which must be used in<br />

the ballast circuit as shown in the wiring diagram in this <strong>Atlas</strong>. The original ballast circuit in the<br />

lighting fixture may have been low or normal power factor, and therefore, no capacitor was used.<br />

If the CWA ballast with its capacitor does not fit in the fixture, contact <strong>Advance</strong> for assistance.<br />

<strong>Advance</strong> Replacement ballasts shown are functionally equivalent to listed obsolete ballasts. Dimensional<br />

differences can exist.<br />

Suffix “T” ballast catalog numbers indicate ballast is equipped with 120V output tap. Standard practice<br />

is to use 120V tap on quadri-volt ballast, where quadri-volt ballasts are available.<br />

Where no replacement ballast is shown, ballast has been discontinued and inventories are exhausted.<br />

Consult nearest <strong>Advance</strong> sales office for assistance.<br />

REFERENCE<br />

MATERIALS<br />

8-41<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109


COMPACT FLUORESCENT LAMP REFERENCE GUIDE<br />

Lamp<br />

Type<br />

Twin<br />

Tube<br />

Quad<br />

Tube<br />

Triple<br />

Tube<br />

2D<br />

Flat<br />

Tube<br />

Twin<br />

Tube<br />

Quad<br />

Tube<br />

Triple<br />

Tube<br />

2D<br />

Long<br />

Twin<br />

Tube<br />

Lamp<br />

Watts<br />

NEMA Lamp<br />

Designation<br />

PHILIPS<br />

GE<br />

OSRAM/<br />

SYLVANIA<br />

PANASONIC<br />

2-Pin lamps with built-in starter<br />

5W CFT5W/G23 PL-S5W F5BX CF5DS - 3-31, 33<br />

7W CFT7W/G23 PL-S7W F7BX CF7DS - 3-31, 33<br />

9W CFT9W/G23 PL-S9W F9BX CF9DS - 3-31, 33<br />

13W CFT13W/GX23 PL-S13W F13BX CF13DS - 3-31, 34<br />

9W CFQ9W/G23 - F9DBX23T4 CF9DD - 3-31, 33<br />

10W CFQ10W/G24d - - - - -<br />

13W CFQ13W/GX23 PL-C13W/USA F13DBX23T4 CF13DD FDS13/2 3-31, 34<br />

13W CFQ13W/G24d PL-C13W F13DBXT4 - - 3-34<br />

16W CFQ15W/GX32d - - - - -<br />

18W CFQ18W/G24d PL-C18W F18DBXT4 CF18DD FDS18/2 3-35<br />

22W CFQ20W/GX32d PL-C15MM/22W - - FDL22 3-32, 35<br />

26W CFQ26W/G24d PL-C26W F26DBXT4 CF26DD FDS26/2 3-32, 35<br />

28W CFQ27W/GX32d PL-C15MM/28W - - FDL28 3-32, 35<br />

13W CFTR13W/GX24d - - - - -<br />

18W CFTR18W/GX24d - - CF18DT - 3-35<br />

26W CFTR26W/GX24d - - CF26DT - 3-35<br />

16W CFS16W/GR8 - - - - -<br />

28W CFS28W/GR8 - F28 2D - - 3-36<br />

4-Pin lamps<br />

18W CFM18W/2G10 - - CF18DF - -<br />

24W CFM24W/2G10 - - CF24DF - -<br />

36W CFM36W/2G10 - - CF36DF - -<br />

5W CFT5W/2G7 - - CF5DS/E - -<br />

7W CFT7W/2G7 - - CF7DS/E - 1-26<br />

9W CFT9W/2G7 - - CF9DS/E - 1-26<br />

13W CFT13W/2GX7 - - CF13DS/E - -<br />

10W CFQ10W/G24q - - - FDS10/4 -<br />

13W CFQ13W/G24q PL-C13W/4P F13DBX/4P CF13DD/E FDS13/4 1-27<br />

18W CFQ18W/G24q PL-C18W/4P F18DBX/4P CF18DD/E FDS18/4 1-28<br />

26W CFQ26W/G24q PL-C26W/4P F26DBX/4P CF26DD/E - 1-28<br />

13W CFTR13W/GX24q - F13TBX/4P CF13DT/E - 1-29<br />

18W CFTR18W/GX24q PL-T18W F18TBX/4P CF18DT/E FHT18 1-30<br />

26W CFTR26W/GX24q PL-T26W F26TBX/4P CF26DT/E FHT26 1-31<br />

32W CFTR32W/GX24q PL-T32W F32TBX/4P CF32DT/E FHT32 1-31<br />

42W CFTR42W/GX24q PL-T42W F42TBX/4P CF42DT/E - 1-32<br />

57W CFTR57W/GX24q - F57QBX/4P CF57DT/E - 1-32<br />

60W PL-H60W/4P - - - 1-33<br />

70W CFTR70W/GX24q - F70QBX/4P - - 1-32<br />

85W PL-H85W/4P - - - 1-33<br />

120W PL-H120W/4P - - - 1-33<br />

10W CFS10W/GR10q - F10 2D/4P - - 1-38<br />

16W CFS16W/GR10q - F16 2D/4P - - 1-38<br />

21W CFS21W/GR10q - F21 2D/4P - - 1-38<br />

28W CFS28W/GR10q - F28 2D/4P - - 1-39<br />

38W CFS38W/GR10q - F38 2D/4P - - 1-39<br />

55W CFS55W/GRY10q - F55 2D/4P - - -<br />

18W FT18W/2G11 PL-L18W F18BX FT18DL - 3-32<br />

18W FT18W/2G11/RS - F18BX/RS FT18DL/RS - 1-34<br />

24-27W FT24W/2G11 PL-L24W F27BX/RS FT24DL - 1-34<br />

36-39W FT36W/2G11 PL-L36W F39BX/RS FT36DL - 1-34<br />

40W FT40W/2G11/RS PL-L40W F40BX FT40DL/RS - 1-35<br />

50W FT50W/2G11/RS PL-L50W F50BX/RS - - 1-36<br />

55W FT55W/2G11 PL-L55W F55BX FT55DL - 1-37<br />

80W FT80W/2G11 PL-L80W - - - 1-37<br />

Page<br />

No.<br />

REFERENCE<br />

MATERIALS<br />

ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-42

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!