<strong>PX</strong> <strong>212</strong><br />

Technical Data Sheet<br />

VACUUM CASTING POLYURETHANE<br />

FOR TECHNICAL PARTS AND PROTOTYPES<br />

FLEXURAL MODULUS 174,000 psi (1,200 MPa)<br />

HDT 194°F (90°C)<br />

Applications<br />

Thermoplastic-like parts (prototypes and mock-ups) with a flexural modulus close to 174,000 psi (1,200 MPa)<br />

(example: polypropylene, HDPE).<br />

Properties<br />

• Low viscosity for easy casting<br />

• Excellent impact resistance<br />

• Fast demolding<br />

• Easily tintable<br />

Physical Properties<br />

<strong>PX</strong> <strong>212</strong> Part A <strong>PX</strong> <strong>212</strong> Part B Mixed<br />

Composition Isocyanate Polyol<br />

Mixing ratio by weight 100 100<br />

Aspect liquid liquid liquid<br />

Color light yellow transparent translucent<br />

Viscosity at 77°F (25°C)<br />

(mPa.s)<br />

Brookfield LVT 150 1,000 800<br />

Density at 77°F (25°C) lbs/gal (g/cc) ISO 1675 : 1985 10.2 (1.22) 8.6 (1.03)<br />

-<br />

Cured density at 74°F (23°C) g/cc ISO 2781 : 1988<br />

-<br />

-<br />

1.15<br />

Pot life at 77°F (25°C) on 100 g (min) 4 – 6<br />

Processing Conditions<br />

• Vacuum casting into silicone molds.<br />

• Heat both parts to 64°F (18°C) when stored at lower temperature.<br />

• Important: vigorously shake Part B Polyol before each and every weighing.<br />

• Degas each part before use.<br />

• Mix for a minimum of 30 seconds.<br />

• Pour into mold preheated to 149 – 158°F (65 – 70°F).<br />

• Cure for 60 – 75 minutes at 158°F (70°C) before demolding<br />

Page 1/2- August 18, 2009, US Rev 01<br />

AXSON NA USA AXSON GmbH AXSON IBERICA AXSON BRASIL AXSON SHANGHAI AXSON JAPAN<br />

1611 Hults Drive Dietzenbach Barcelona Sao Paulo Shanghai OKAZAKI CITY<br />

Eaton Rapids, MI Tél. (++49) 60 74 407110 Tel. (++34) 93 225 16 20 Tel. (++55) 11 5687 7331 Tel. (++86)-58 68 30 37 Tel.(++81) 564 26 2591<br />

48827<br />

Tel. (517) 663-8191 AXSON Italie AXSON UK Limited AXSON MEXICO AXSON France<br />

Fax (517) 663-0523 Saronno Newmarket Mexico DF Cergy<br />

Email : info@axson-na.com Tel. (++39) 02 96 70 23 36 Tel. (++44) 1638 660 062 Tel. (++52) 55 5264 49 22 Tél. (++33) 1 34 40 34 60<br />

Email : axson@axson.fr


<strong>PX</strong> <strong>212</strong><br />

Technical Data Sheet<br />

VACUUM CASTING POLYURETHANE<br />

FOR TECHNICAL PARTS AND PROTOTYPES<br />

FLEXURAL MODULUS 174,000 psi (1,200 MPa)<br />

HDT 194°F (90°C)<br />

Mechanical Properties at 74°F (23°C)<br />

Flexural modulus of elasticity ISO 178 : 2001 psi (MPa) 174,000 (1,200)<br />

Flexural strength ISO 178 : 2001 psi (MPa) 11,600 (80)<br />

Tensile strength ISO 527 : 1993 psi (MPa) 10,900 (75)<br />

Elongation at break in tension ISO 527 : 1993 % 25<br />

Charpy impact strength ISO 179/1eU : 1994 ft-lb/in 2 (kJ/m 2 ) >23.8 (50)<br />

Hardness<br />

– 74°F (23°C)<br />

– 176°F (80°C)<br />

ISO 868 : 1985<br />

Shore D1<br />

Thermal and Specific Properties 1<br />

Glass transition temperature (Tg) TMA METTLER °F (°C) 194 (90)<br />

Heat deflection temperature at 264 psi<br />

(1.8 MPa)<br />

ISO 75 Ae : 1993 °F (°C) 172 (78)<br />

Linear shrinkage % 0.3%<br />

Time before demolding at 158°F (70°C) minutes 60 – 75<br />

Complete hardening time at 158°F (70°C) hours 4<br />

Maximal casting thickness in (mm) 0.2 (5)<br />

1 Average values obtained on standardized specimens/postcured 4 hours at 158°F (70°C)<br />

Storage Conditions<br />

Product shelf life is 6 months when stored in original unopened containers between 59 – 77°F (15 – 25°C). Any<br />

opened can must be tightly closed under protective gas blanket, such as Bloxygen (available from Axson).<br />

Part A (Isocyanate) may crystallize at temperatures below 59°F (15°C) as indicated by a non-homgeneous<br />

appearance, heat product to 158°F (70°C) until uniform.<br />

Part B (Polyol) separates rapidly in storage. Please shake vigorously before each use to ensure best results.<br />

Handling Precautions<br />

Normal health and safety precautions should be observed when handling these products:<br />

• Ensure good ventilation<br />

• Wear gloves and safety glasses<br />

For further information, please consult the material safety data sheet.<br />

Guarantee<br />

The information contained in this technical data sheet results from research and tests conducted in our Laboratories under precise conditions.<br />

It is the responsibility of the user to determine the suitability of AXSON products, under their own conditions before commencing with the<br />

proposed application. AXSON guarantees the conformity of their products with their specifications but cannot guarantee the compatibility of a<br />

product with any particular application. AXSON disclaims all responsibility for damage from any incident which results from the use of these<br />

products. The responsibility of AXSON is strictly limited to reimbursement or replacement of products which do not comply with the published<br />

specifications.<br />

76<br />

68<br />

Page 2/2- August 18, 2009, US Rev 01<br />

AXSON NA USA AXSON GmbH AXSON IBERICA AXSON BRASIL AXSON SHANGHAI AXSON JAPAN<br />

1611 Hults Drive Dietzenbach Barcelona Sao Paulo Shanghai OKAZAKI CITY<br />

Eaton Rapids, MI Tél. (++49) 60 74 407110 Tel. (++34) 93 225 16 20 Tel. (++55) 11 5687 7331 Tel. (++86)-58 68 30 37 Tel.(++81) 564 26 2591<br />

48827<br />

Tel. (517) 663-8191 AXSON Italie AXSON UK Limited AXSON MEXICO AXSON France<br />

Fax (517) 663-0523 Saronno Newmarket Mexico DF Cergy<br />

Email : info@axson-na.com Tel. (++39) 02 96 70 23 36 Tel. (++44) 1638 660 062 Tel. (++52) 55 5264 49 22 Tél. (++33) 1 34 40 34 60<br />

Email : axson@axson.fr

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!