SPECIFICATION<br />

POTASH: COMPACTOR EXPANSION SECTION: 41 12 16<br />

BUCKET ELEVATORS<br />

EQUIPMENT SPECIFICATION<br />

ENQUIRY NUMBER: REV. A, PAGE: 3 OF 10<br />

4.3.7 Chain links shall be made of high tensile drop forged<br />

nickel alloy steel with case hardened chrome alloy steel<br />

pins.<br />

4.3.8 The Vendor shall confirm material selection where<br />

specified. Otherwise the Vendor shall specify materials of<br />

construction with corrosion and erosion allowances.<br />

4.4 Specific Equipment Requirements<br />

4.4.1 General<br />

4.4.1.1 Vendor shall propose units with as many common components<br />

as possible.<br />

4.4.1.2 <strong>Bucket</strong> elevators shall be continuous discharge, double<br />

chain bucket type and shall be manufacturer’s standard size<br />

and design, modified only as required and suitable for duty<br />

specified.<br />

4.4.1.3 For each bucket elevator, Vendor shall advise price<br />

adder/discount schedule for increasing/reducing the height<br />

of the bucket elevator (+/- 0 to 20%). Price<br />

adder/discount shall account for all changes required to<br />

extend/reduce the height of the elevator. This includes<br />

but is not limited to; drive, power train sizing, shafts,<br />

bearings, chain, casing, etc. This data will be used to<br />

finalize pricing of the units before issuing the Purchase<br />

Order, as layouts are still in development.<br />

4.4.1.4 <strong>Bucket</strong> elevators shall be designed with a bucket filling<br />

rate of 60% by volume at normal operating flow rate and<br />

using the minimum density of material. Elevator power<br />

calculation shall be based on buckets filled to 100% of the<br />

theoretical capacity with maximum density material allowing<br />

adequate provision for digging load.<br />

4.4.1.5 Casing design shall be dust-tight and weatherproof. Dusttight<br />

inspection and repair doors shall be provided as<br />

required for proper inspection and maintenance. A vent<br />

connection flange (6” standard pipe flange) for dedusting<br />

purposes shall be provided at the head and boot sections.<br />

4.4.1.6 The elevator casing shall be fabricated of steel plate,<br />

adequately braced and stiffened so as to be completely<br />

self-supporting. Minimum thickness shall be 6 mm.<br />

4.4.1.7 The bucket elevators shall be provided with a counterweight<br />

– type chain tensioning device, complete with weights.<br />

4.4.1.8 Elevator shall be capable of starting from a full load<br />

condition, including digging factor.<br />