“OFF” Setting<br />
<br />
<br />
Timer settings<br />
Design <strong>flow</strong> ÷ Gal per dose = # of Doses<br />
• 450 gpd ÷ 55 gal = 8 doses per day<br />
1440 minutes ÷ # of doses - On time = Off time<br />
• 1440 min ÷ 8 doses – 1.25 min. = 178.75 min<br />
• 178.75 min ÷ 60 min/hr = 2.9 hours