05.11.2012 Views

Coaxial Cables - RG Coaxial and Triaxial Reference Guide - Belden

Coaxial Cables - RG Coaxial and Triaxial Reference Guide - Belden

Coaxial Cables - RG Coaxial and Triaxial Reference Guide - Belden

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

C O A X I A L C A B L E S 6.6<br />

<strong>RG</strong> <strong>Coaxial</strong> <strong>and</strong> <strong>Triaxial</strong> <strong>Reference</strong> <strong>Guide</strong><br />

<strong>RG</strong>-6 Type<br />

Cable Designation<br />

Part<br />

No.<br />

Page<br />

No.<br />

Spec.<br />

<strong>Reference</strong><br />

Conductor<br />

Str<strong>and</strong>ing/<br />

Dia. & Type*<br />

(DCR/1000 Ft.)<br />

Insulation<br />

Material<br />

(OD in.)<br />

Shield Type<br />

Tape/Braid<br />

(DCR/1000 Ft.)<br />

Jacket<br />

Material<br />

(OD in.)<br />

Nom.<br />

Weight<br />

(Lbs./Ft.)<br />

Nom.<br />

Cap.<br />

(pF/Ft.)<br />

For more information, contact <strong>Belden</strong> Technical Support: 1-800-BELDEN-1 • www.belden.com<br />

Nom.<br />

Imp.<br />

(Ω)<br />

Suggested<br />

Operating<br />

Temp. Range<br />

(°C) UL<br />

Max. Oper.<br />

Voltage<br />

(RMS)<br />

Non UL<br />

<strong>RG</strong>-6 Type (continued)<br />

<strong>RG</strong>-6/U Type 1839A 6.32 <strong>Belden</strong> 1/.040″ BCCS GIFPE DBII/60% AL PVC .040 75 16.2 -40 to +80 300<br />

Static Ground (28.0) (.180) (9.0) (.270 x .405)<br />

<strong>RG</strong>-6/U Type 1839AC 6.32 <strong>Belden</strong> 1/.040″ BCAC GIFPE DBII/60% AL PVC .040 75 16.2 -40 to +80 300<br />

Static Ground (6.4) (.180) (9.0) (.270 x .405)<br />

<strong>RG</strong>-6/U Type 1840A 6.32 <strong>Belden</strong> 2/.040″ BCAC GIFPE DBII/60% AL PVC .069 75 16.2 -40 to +80 300<br />

Static Ground (28.0) (.180) (9.0) (.273 x .703)<br />

<strong>RG</strong>-6/U Type 1840AC 6.32 <strong>Belden</strong> 2/.040″ BC GIFPE DBII/60% AL PVC .069 75 16.2 -40 to +80 300<br />

Static Ground (6.4) (.180) (9.0) (.273 x .703)<br />

<strong>RG</strong>-6/U Type 1841A 6.32 <strong>Belden</strong> 2/.040″ BCCS GIFPE DBII/60% AL PVC .058 75 16.2 -40 to +80 300<br />

(28.0) (.180) (9.0) (.273 x .595)<br />

<strong>RG</strong>-6/U Type 1841AC 6.32 <strong>Belden</strong> 2/.040″ BCAC GIFPE DBII/60% AL PVC .058 75 16.2 -40 to +80 300<br />

(6.4) (.180) (9.0) (.273 x .595)<br />

<strong>RG</strong>-6/U Type 1843A 6.33 <strong>Belden</strong> 1/.040″ BCCS GIFPE DBII/60% AL PE .052 75 16.2 -55 to +80 300<br />

Burial (28.0) (.180) (9.0) (.273 x .750)<br />

<strong>RG</strong>-6/U Type 3131A 6.84 <strong>Belden</strong> 1/.040″ BCCS FPE DBIV/67% AL PVC .033 75 16.2 -30 to +75 3000<br />

(28.0) (.180) 46% AL<br />

(3.6)<br />

(.300)<br />

<strong>RG</strong>-6/U Type 3132A 6.84 <strong>Belden</strong> 1/.040″ BCCS FFPE DBIV/67% AL PVDF .043 75 16.3 -20 to +150 300<br />

(28.0) (.170) 46% AL<br />

(7.2)<br />

(.274)<br />

<strong>RG</strong>-6/U Type 5339G5 6.21 <strong>Belden</strong> 1/.040″ BCCS GIFPE BB/50% AL PVC .024 75 16.2 -40 to +80 300<br />

(28.0) (.180) (15.0) (.253)<br />

<strong>RG</strong>-6/U Type 7915A 6.33 <strong>Belden</strong> 1/.040″ BC GIFPE DB+/77% AL PVC .029 75 16.2 -40 to +80 300<br />

(6.4) (.180) (4.6) (.275)<br />

<strong>RG</strong>-6/U Type 7916A 6.33 <strong>Belden</strong> 1/.040″ BC GIFPE DBIV/60% AL PVC .032 75 16.2 -40 to +80 300<br />

(6.4) (.180) 40% AL<br />

(4.8)<br />

(.298)<br />

<strong>RG</strong>-6/U Type 8215 6.38 <strong>Belden</strong> 1/.028″ BCCS PE None/96% BC PE .069 75 20.5 -55 to +80 2,700<br />

(32.0) (.185) None/95% BC<br />

(1.1)<br />

(.332)<br />

<strong>RG</strong>-6/U Type 8238 6.39 JAN-C-17A 7/.048″ TC FRSFPE None/97% BC PVC .117 75 20.5 -40 to +80 300<br />

(6.1) (.285) (1.2) (.405)<br />

<strong>RG</strong>-6/U Type 8261 6.39 MIL-C-17D 7/.048″ TC PE None/97% BC PVC .104 75 20.5 -40 to +60 3,700<br />

(6.1) (.285) (1.2) (.405)<br />

<strong>RG</strong>-6/U Type 9058 6.23 <strong>Belden</strong> 1/.040″ BCCS GIFPE DB+/77% AL PVC .029 75 16.2 -40 to +80 300<br />

(28.0) (.180) (5.6) (.275)<br />

<strong>RG</strong>-6/U Type 9058M 6.23 <strong>Belden</strong> 1/.040″ BCCS GIFPE DB+/77% AL PVC .043 75 16.2 -40 to +80 350<br />

Messengered (28.0) (.180) (5.6) (.275 x .416)<br />

<strong>RG</strong>-6/U Type 9062 6.23 <strong>Belden</strong> 1/.040″ BCCS GIFPE DB+/77% AL PVC .023 75 16.2 -55 to +80 300<br />

Burial (28.0) (.180) (5.6) (.275)<br />

<strong>RG</strong>-6/U Type 9066 6.19 <strong>Belden</strong> 1/.040″ BCCS GIFPE DBII/60% AL PE .026 75 16.2 -55 to +80 300<br />

Burial (28.0) (.180) (9.0) (.270)<br />

<strong>RG</strong>-6/U Type 9077 6.19 <strong>Belden</strong> 2/.040″ BCCS GIFPE DBII/60% AL PVC .057 75 16.2 -40 to +80 300<br />

(28.0) (.180) (9.0) (.270 x .590)<br />

<strong>RG</strong>-6/U Type 9116 6.19 <strong>Belden</strong> 1/.040″ BCCS GIFPE DBII/60% AL PVC .030 75 16.2 -40 to +80 300<br />

(28.0) (.180) (9.0) (.270)<br />

<strong>RG</strong>-6/U Type 9116P 6.19 <strong>Belden</strong> 1/.040″ BCCS FFEP DBII/60% AL FLM .025 75 16.3 -20 to +75 300<br />

Plenum (28.0) (.170) (9.0) (.235)<br />

<strong>RG</strong>-6/U Type 9116R 6.19 <strong>Belden</strong> 1/.040″ BCCS GIFPE DBII/60% AL PVC .030 75 16.2 -40 to +80 300<br />

Riser (28.0) (.180) (9.0) (.270)<br />

<strong>RG</strong>-6/U Type 9116SB 6.19 <strong>Belden</strong> 1/.040″ BCCS GIFPE DBII/60% AL LSZH .031 75 16.2 -30 to +75 300<br />

(28.0) (.180) (9.0) (.274)<br />

<strong>RG</strong>-6/U Type 9117M 6.19 <strong>Belden</strong> 1/.040″ BCCS GIFPE DBII/60% AL PVC .042 75 16.2 -40 to +80 300<br />

Messengered (28.0) (.180) (9.0) (.270 x .410)<br />

<strong>RG</strong>-6/U Type 9118 6.21 <strong>Belden</strong> 1/.040″ BCCS GIFPE DBIII/60% AL PVC .026 75 16.2 -40 to +80 300<br />

(28.0) (.180) (6.8) (.275)<br />

<strong>RG</strong>-6/U Type 9119M 6.21 <strong>Belden</strong> 1/.040″ BCCS GIFPE DBIII/60% AL PVC .042 75 16.2 -40 to +80 300<br />

Messengered (28.0) (.180) (6.5) (.275 x .416)<br />

<strong>RG</strong>-6/U Type 9248 6.38 <strong>Belden</strong> 1/.040″ BC GIFHDPE DF/65% TC PVC .030 75 16.2 -40 to +80 300<br />

(6.4) (.180) (5.6) (.270)<br />

<strong>RG</strong>-6/U Type 9290 6.38 <strong>Belden</strong> 1/.037″ BC FPE None/95% BC PVC .054 75 17.3 -40 to +80 300<br />

(7.5) (.180) None/95% BC<br />

(2.0)<br />

(.288)<br />

*Inner conductors are entered as: number of str<strong>and</strong>s/str<strong>and</strong> diameter (in inches). See page 6.15 for key to abbreviations used in this table.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!