Lab- and Cleanroom Equipment halitec® - Hammerlit
Lab- and Cleanroom Equipment halitec® - Hammerlit
Lab- and Cleanroom Equipment halitec® - Hammerlit
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Cleanroom</strong><br />
equipment<br />
172 <strong>Hammerlit</strong> GmbH<br />
Stainless Cabinet<br />
Closed stainless steel cabinet. Equipped with 4 height-adjustable shelves, 2<br />
lockable double-paned doors on 120° non-abrasive ESD hinges.<br />
Top of cabinet <strong>and</strong> all shelves are available with optional perforated surfaces.<br />
Base of the unit can also be equipped with height-adjustable feet.<br />
Dimensions WDH Model-No.<br />
1000 x 450 x 2000 mm 001SK2FT100045G<br />
1200 x 450 x 2000 mm 001SK2FT120045G<br />
1000 x 550 x 2000 mm 001SK2FT100055G<br />
1200 x 550 x 2000 mm 001SK2FT120055G<br />
1000 x 650 x 2000 mm 001SK2FT100065G<br />
1200 x 650 x 2000 mm 001SK2FT120065G<br />
Other dimensions <strong>and</strong> surface structure are available on request! Please<br />
contact us!<br />
Horizontal <strong>and</strong> vertical inserts<br />
individual compartments available, custom sizes <strong>and</strong><br />
configurations available,<br />
– Automatically Nitrogen- purged system maintain<br />
an internal humidity level down to 0% RH.<br />
– ESD-solution<br />
– His dry environment retards oxidation <strong>and</strong> other<br />
chemical reactions <strong>and</strong> protect the items.<br />
Stainless Cabinet<br />
Stainless steel cabinet with Nitrogen Flushing System /optional<br />
with heating.<br />
Dimensions <strong>and</strong> numbers of chambers customized.<br />
Storage of sensitive products e.g. reticle cassettes / wafers or parts which<br />
must be protected from humidity <strong>and</strong> particle influences <strong>and</strong> for to reduce<br />
corrosion .<br />
The automatic N 2 Flushing System reduced humidity to a lower level <strong>and</strong> the<br />
particle influence is stopped when doors are open <strong>and</strong> fast flushing is on.<br />
Closed doors , fast flushing is changing to permanent flushing.<br />
Operations are shown at the display.<br />
Alarm indicator <strong>and</strong> signal if 1 door is open longer than 30 seconds or more<br />
than1 door, in case of errors <strong>and</strong> if N 2 input pressure is lower as specified.<br />
220/240 V AC 50/60 Hz N 2 / 3.5-6 bar.<br />
Option: Heating for N 2 input.<br />
The temperature inside the cabinet is same as invironment.<br />
Stepless calibration <strong>and</strong> shown at the display.