eCO2<br />

TM<br />

ANSWERING <strong>THE</strong> <strong>NEED</strong> <strong>FOR</strong> <strong>BETTER</strong> FRACTIONAL TECHNOLOGY.<br />

SYSTEM SPECIFICATIONS<br />

Laser Wavelength 10.6 µm<br />

Medium of Transmission<br />

Sealed off CO2 RF Module Laser<br />

Laser Transfer Method<br />

Articulated Arm with Handpiece<br />

CO2 RF Module Maximum power<br />

Maximum 30 Watt at Continuous Wave<br />

Scanner Handpiece User Mode STATIC / DYNAMIC<br />

Pulse Energy<br />

2 mJ ~ 240 mJ<br />

Pulse Rate 10 Hz ~ 200 Hz<br />

Density 25 ~ 400 spots/cm 2<br />

Scan Area Max. 14 x 14 mm<br />

<br />

Scan Type<br />

<br />

Dual Beam Pattern<br />

<br />

Handpiece Tips<br />

(Distinct interchangeable<br />

spot sizes)<br />

Random Linear<br />

120µ spot 300µ spot 1000µ spot<br />

1-17% cov. per pass 5-58% cov. per pass 20-130% cov. per pass<br />

Normal Handpiece User Mode Char Free (Ultra Pulse) / Super Pulse / CW<br />

<strong>Lutronic</strong>, Inc. U.S. Headquarters<br />

3003 N. First St., Suite 235<br />

San Jose, CA 95134<br />

The Healing Power of Light<br />

Pulse Rate Char Free (Ultra Pulse) 1 Hz ~ 700 Hz<br />

Super Pulse 1 Hz ~ 400 Hz<br />

Pulse Width Char Free (Ultra Pulse) 40 µs ~ 1,000 µs<br />

Super Pulse 1 ms ~ 5 ms<br />

CW ON Time CONT, 0.01 s ~ 1.0 s<br />

OFF Time SINGLE, 0.01 s ~ 1.0 s<br />

User Interface<br />

Dimensions (mm)<br />

Weight (excluding the arm)<br />

Cooling Method<br />

<strong>Lutronic</strong>, Inc. R+D Center<br />

48890 Milmont Dr., Suite 106 D<br />

Fremont, CA 94538<br />

Touch LCD type, 7” LCD<br />

360 (W) x 450 (L) x1870 (H)<br />

48 kg<br />

Air Cooling<br />

<strong>Lutronic</strong>, Inc. East Coast Office<br />

Six Neshaminy Interplex, Suite 207<br />

Trevose, PA 19053<br />

WWW.LUTRONIC.COM | CONTACT@LUTRONIC.COM | 888.588.7644<br />

©2012 <strong>Lutronic</strong>, Inc. All rights reserved. <strong>Lutronic</strong> is a registered trademark of <strong>Lutronic</strong> Corp.<br />

eCO2 is a trademark of <strong>Lutronic</strong> Inc.<br />

eC02<br />

ANSWERING <strong>THE</strong> <strong>NEED</strong> <strong>FOR</strong><br />

<strong>BETTER</strong> FRACTIONAL TECHNOLOGY.<br />

TM<br />

The Healing Power of Light


eCO2’S INNOVATIVE<br />

TECHNOLOGIES FEATURING:<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

2<br />

laser handpiece<br />

available on eCO2 Plus<br />

MINIMAL DOWNTIME<br />

& LESS DISCOM<strong>FOR</strong>T<br />

Common Indications for Use:<br />

<br />

<br />

(e.g. acne and surgical scars)<br />

<br />

<br />

<br />

eC02<br />

TM<br />

ENGINEERED <strong>FOR</strong> YOUR<br />

GROWING PRACTICE<br />

<br />

<br />

<br />

<br />

VERSATILE, STABLE, POWERFUL<br />

FRACTIONAL TECHNOLOGY<br />

<strong>Lutronic</strong>’s eCO2 laser establishes a new generation of<br />

CO 2<br />

fractional resurfacing. It combines versatility and<br />

user-friendly dual mode technology with the deep<br />

ablative properties of a CO 2<br />

laser system.<br />

Superficially targeting the epidermis or promoting<br />

collagen remodeling deep in the reticular dermis,<br />

the eCO2 effectively and dramatically treats multiple<br />

dermatologic indications. Measurably shorter treatment<br />

times are more comfortable for patients. Recovery is<br />

rapid, with minimal downtime. Advanced capabilities<br />

Mark G. Rubin, M.D.<br />

Dermatologist,<br />

Beverly Hills, CA, USA<br />

“The technology behind<br />

eCO2 fills a niche we’ve<br />

been trying to fill for years,<br />

in that patients experience<br />

dramatically better results<br />

and more rapid post-treatment<br />

healing than with the<br />

old ablative techniques.”<br />

and intuitive functionality allow clinicians to deliver<br />

customized treatments with dynamic and longlasting<br />

results.<br />

Choice of beam patterns and wide range of tips allows<br />

for treatment flexibility in both area and depth. Our<br />

<br />

the foot pedal, allows continuous firing of the laser.<br />

Contributing to eCO2’s clinical superiority, this feature<br />

is time-efficient for physicians and affords the patient<br />

a faster treatment.<br />

J. David Holcomb, M.D.<br />

Facial Plastic Surgeon,<br />

Sarasota, FL, USA<br />

“... a familiar wavelength in<br />

an extremely elegant and<br />

versatile package ... with the<br />

ability to perform incisional<br />

surgery, ablative resurfacing<br />

and ablative microfractional<br />

photothermolysis ...”<br />

BE<strong>FOR</strong>E AFTER BE<strong>FOR</strong>E AFTER<br />

Acne Scars, Courtesy of J. Rapaport, M.D., USA<br />

Post 2 months<br />

1 treatment<br />

Rhytides and Dyschromia, Courtesy of Julie Woodward, M.D., USA<br />

Post 3 months<br />

1 treatment<br />

Rhytides, Courtesy of J. Rapaport, M.D., USA<br />

Post 1 month<br />

1 treatment<br />

ECO2 CAN BE UPGRADED<br />

TO ECO2 PLUS<br />

(not available for glass tube type)<br />

eCO2 PLUS has additional handpiece<br />

for conventional surgical application.<br />

Rhytides, Courtesy of J. David Holcomb, M.D., USA<br />

Post 2.5 months<br />

2 treatments<br />

Hypertrophic Scar<br />

Post 2 weeks<br />

3 treatments<br />

Hypertrophic Scar, Courtesy of Hernando Harker, M.D., Colombia<br />

FRACTIONAL MODE<br />

CONVENTIONAL MODE<br />

Post 9 months<br />

1 treatment<br />

Activated with<br />

scanner handpiece<br />

Activated with<br />

normal handpiece