eC02ANSWERING THE NEED FOR BETTER ... - Lutronic
eC02ANSWERING THE NEED FOR BETTER ... - Lutronic
eC02ANSWERING THE NEED FOR BETTER ... - Lutronic
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
eCO2<br />
TM<br />
ANSWERING <strong>THE</strong> <strong>NEED</strong> <strong>FOR</strong> <strong>BETTER</strong> FRACTIONAL TECHNOLOGY.<br />
SYSTEM SPECIFICATIONS<br />
Laser Wavelength 10.6 µm<br />
Medium of Transmission<br />
Sealed off CO2 RF Module Laser<br />
Laser Transfer Method<br />
Articulated Arm with Handpiece<br />
CO2 RF Module Maximum power<br />
Maximum 30 Watt at Continuous Wave<br />
Scanner Handpiece User Mode STATIC / DYNAMIC<br />
Pulse Energy<br />
2 mJ ~ 240 mJ<br />
Pulse Rate 10 Hz ~ 200 Hz<br />
Density 25 ~ 400 spots/cm 2<br />
Scan Area Max. 14 x 14 mm<br />
<br />
Scan Type<br />
<br />
Dual Beam Pattern<br />
<br />
Handpiece Tips<br />
(Distinct interchangeable<br />
spot sizes)<br />
Random Linear<br />
120µ spot 300µ spot 1000µ spot<br />
1-17% cov. per pass 5-58% cov. per pass 20-130% cov. per pass<br />
Normal Handpiece User Mode Char Free (Ultra Pulse) / Super Pulse / CW<br />
<strong>Lutronic</strong>, Inc. U.S. Headquarters<br />
3003 N. First St., Suite 235<br />
San Jose, CA 95134<br />
The Healing Power of Light<br />
Pulse Rate Char Free (Ultra Pulse) 1 Hz ~ 700 Hz<br />
Super Pulse 1 Hz ~ 400 Hz<br />
Pulse Width Char Free (Ultra Pulse) 40 µs ~ 1,000 µs<br />
Super Pulse 1 ms ~ 5 ms<br />
CW ON Time CONT, 0.01 s ~ 1.0 s<br />
OFF Time SINGLE, 0.01 s ~ 1.0 s<br />
User Interface<br />
Dimensions (mm)<br />
Weight (excluding the arm)<br />
Cooling Method<br />
<strong>Lutronic</strong>, Inc. R+D Center<br />
48890 Milmont Dr., Suite 106 D<br />
Fremont, CA 94538<br />
Touch LCD type, 7” LCD<br />
360 (W) x 450 (L) x1870 (H)<br />
48 kg<br />
Air Cooling<br />
<strong>Lutronic</strong>, Inc. East Coast Office<br />
Six Neshaminy Interplex, Suite 207<br />
Trevose, PA 19053<br />
WWW.LUTRONIC.COM | CONTACT@LUTRONIC.COM | 888.588.7644<br />
©2012 <strong>Lutronic</strong>, Inc. All rights reserved. <strong>Lutronic</strong> is a registered trademark of <strong>Lutronic</strong> Corp.<br />
eCO2 is a trademark of <strong>Lutronic</strong> Inc.<br />
eC02<br />
ANSWERING <strong>THE</strong> <strong>NEED</strong> <strong>FOR</strong><br />
<strong>BETTER</strong> FRACTIONAL TECHNOLOGY.<br />
TM<br />
The Healing Power of Light
eCO2’S INNOVATIVE<br />
TECHNOLOGIES FEATURING:<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
2<br />
laser handpiece<br />
available on eCO2 Plus<br />
MINIMAL DOWNTIME<br />
& LESS DISCOM<strong>FOR</strong>T<br />
Common Indications for Use:<br />
<br />
<br />
(e.g. acne and surgical scars)<br />
<br />
<br />
<br />
eC02<br />
TM<br />
ENGINEERED <strong>FOR</strong> YOUR<br />
GROWING PRACTICE<br />
<br />
<br />
<br />
<br />
VERSATILE, STABLE, POWERFUL<br />
FRACTIONAL TECHNOLOGY<br />
<strong>Lutronic</strong>’s eCO2 laser establishes a new generation of<br />
CO 2<br />
fractional resurfacing. It combines versatility and<br />
user-friendly dual mode technology with the deep<br />
ablative properties of a CO 2<br />
laser system.<br />
Superficially targeting the epidermis or promoting<br />
collagen remodeling deep in the reticular dermis,<br />
the eCO2 effectively and dramatically treats multiple<br />
dermatologic indications. Measurably shorter treatment<br />
times are more comfortable for patients. Recovery is<br />
rapid, with minimal downtime. Advanced capabilities<br />
Mark G. Rubin, M.D.<br />
Dermatologist,<br />
Beverly Hills, CA, USA<br />
“The technology behind<br />
eCO2 fills a niche we’ve<br />
been trying to fill for years,<br />
in that patients experience<br />
dramatically better results<br />
and more rapid post-treatment<br />
healing than with the<br />
old ablative techniques.”<br />
and intuitive functionality allow clinicians to deliver<br />
customized treatments with dynamic and longlasting<br />
results.<br />
Choice of beam patterns and wide range of tips allows<br />
for treatment flexibility in both area and depth. Our<br />
<br />
the foot pedal, allows continuous firing of the laser.<br />
Contributing to eCO2’s clinical superiority, this feature<br />
is time-efficient for physicians and affords the patient<br />
a faster treatment.<br />
J. David Holcomb, M.D.<br />
Facial Plastic Surgeon,<br />
Sarasota, FL, USA<br />
“... a familiar wavelength in<br />
an extremely elegant and<br />
versatile package ... with the<br />
ability to perform incisional<br />
surgery, ablative resurfacing<br />
and ablative microfractional<br />
photothermolysis ...”<br />
BE<strong>FOR</strong>E AFTER BE<strong>FOR</strong>E AFTER<br />
Acne Scars, Courtesy of J. Rapaport, M.D., USA<br />
Post 2 months<br />
1 treatment<br />
Rhytides and Dyschromia, Courtesy of Julie Woodward, M.D., USA<br />
Post 3 months<br />
1 treatment<br />
Rhytides, Courtesy of J. Rapaport, M.D., USA<br />
Post 1 month<br />
1 treatment<br />
ECO2 CAN BE UPGRADED<br />
TO ECO2 PLUS<br />
(not available for glass tube type)<br />
eCO2 PLUS has additional handpiece<br />
for conventional surgical application.<br />
Rhytides, Courtesy of J. David Holcomb, M.D., USA<br />
Post 2.5 months<br />
2 treatments<br />
Hypertrophic Scar<br />
Post 2 weeks<br />
3 treatments<br />
Hypertrophic Scar, Courtesy of Hernando Harker, M.D., Colombia<br />
FRACTIONAL MODE<br />
CONVENTIONAL MODE<br />
Post 9 months<br />
1 treatment<br />
Activated with<br />
scanner handpiece<br />
Activated with<br />
normal handpiece