11.01.2015 Views

Aesthetic & Medical Laser Systems - Lutronic

Aesthetic & Medical Laser Systems - Lutronic

Aesthetic & Medical Laser Systems - Lutronic

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Aesthetic</strong> &<br />

<strong>Medical</strong> <strong>Laser</strong><br />

<strong>Systems</strong><br />

Innovative <strong>Systems</strong>.<br />

Proven Science.<br />

Exceptional Value.<br />

California Office<br />

Pennslyvania Office<br />

GLOBAL HEADQUARTERS<br />

Japan Office<br />

ACCUSCULPT II ADVANTAGE HEALITE II eCO 2 SPECTRA<br />

China Office<br />

US HEADQUARTERS / R&D<br />

850 Auburn Court<br />

Fremont, CA 94538<br />

EAST COAST OFFICE<br />

Six Neshaminy Interplex, Suite 207<br />

Trevose, PA 19053<br />

THESE LASER PRODUCT COMPLIES WITH FEDERAL PERFORMANCE STANDARD 21 CFR. 1040.10 AND 1040.11 FOR CLASS IV LASER PRODUCTS - CE 0434, FDA CLEARED.<br />

©2013, LUTRONIC Group of Companies. All rights reserved. LUTRONIC, its logo and ADVANTAGE, eCO2, ACCUSCULPT II, HEALITE II & SPECTRA are trademarks or registered trademarks of the LUTRONIC Group of<br />

Companies. Specifications are subject to change without notice. This product or the use of this product is covered by one or more US and foreign patents or patent application pending.<br />

LUTRONIC-BR-4100151000


The World Relies on <strong>Lutronic</strong> Products<br />

Established in 1997 by a group of accomplished scientists and prominent members of<br />

the medical community, LUTRONIC is passionate about improving the lives of physicians<br />

and their patients by developing solutions that are intuitive, versatile, and efficacious.<br />

Our customers choose our systems because they are easy to use, innovative as well as<br />

affordable.<br />

Currently, <strong>Lutronic</strong> dedicates more than 15% of revenues in R&D,<br />

holding more than 70 patents and continues to invest in the<br />

development of devices that offer features and improvements not<br />

found in the market today.<br />

<strong>Lutronic</strong> is also dedicated to furthering the clinical efficacy of our<br />

devices through partnership with leading physicians and key<br />

opinion leaders in their respective fields. These partnerships ensure<br />

that our systems are innovative, relevant and most of all effective.<br />

“They focus on solid-state devices that<br />

are reliable, and their international reputation<br />

for safety and efficacy is strong.<br />

<strong>Lutronic</strong> is forward-thinking, innovative<br />

and willing to constantly improve.”<br />

— J. David Holcomb, M.D.<br />

Facial Plastic Surgeon in Sarasota, Florida and<br />

past president of the Florida Society of Facial<br />

Plastic and Reconstructive Surgery<br />

<strong>Lutronic</strong> Timeline<br />

Start of <strong>Medical</strong><br />

<strong>Laser</strong>s Development<br />

1997<br />

R&D Center established<br />

First Product Introduction:<br />

Spectra VRM (Q-switched<br />

Nd:YAG <strong>Laser</strong>)<br />

<strong>Lutronic</strong> receives<br />

multiple awards for<br />

Design, Innovation<br />

and Export.<br />

Approved by NSAI<br />

show systems for ISO<br />

9001 and EN 46001<br />

2000 2002<br />

Spectra QT gains<br />

FDA clearance<br />

Presented<br />

Presidential<br />

Award received<br />

from Ministry of<br />

Commerce &<br />

Industry,<br />

South Korea<br />

200404<br />

2005<br />

Listed on<br />

Awarded Global<br />

Brand and World<br />

Class Design<br />

Development<br />

MAX Engineering<br />

becomes <strong>Lutronic</strong><br />

Corporation<br />

Accusculpt I,<br />

eCO2 & Spectra<br />

VRM III gains<br />

FDA clearance<br />

2007<br />

2009<br />

Accusculpt II gains<br />

FDA clearance<br />

R&D center established<br />

in Silicon Valley, US<br />

Selected as member of<br />

‘Global Small but Strong’<br />

by SMBA and ‘Advanced<br />

Technology Center’ by<br />

Ministry of Knowledge<br />

Economy, S. Korea<br />

2011<br />

Advantage &<br />

Healite II gain<br />

FDA clearance<br />

Infini receives<br />

CE mark<br />

Spectra for<br />

Melasma gains<br />

FDA clearance<br />

1998<br />

1999 2001<br />

2003<br />

2006<br />

2008<br />

2010 2012<br />

<strong>Lutronic</strong> founded<br />

by Haelyung Hwang<br />

Ministry of Science<br />

& Technology<br />

Approved as Venture<br />

Corporation<br />

Spectra VRM,<br />

first product to gain<br />

FDA clearance<br />

Spectra VRM,<br />

first product to<br />

receive CE mark<br />

Received World<br />

Class Product<br />

Award<br />

Granted Equity<br />

Investment<br />

Release of<br />

Solid-State<br />

Dye <strong>Laser</strong><br />

Quality System<br />

Upgrade to I.S.<br />

EN 13485:2000<br />

by NSAI<br />

Spectra VRM gains<br />

SFDA (Chinese FDA)<br />

clearance<br />

Spectra VRM II,<br />

Spectra SP & Action<br />

receive CE mark<br />

Approved by CE<br />

for SPECTRA SP<br />

Spectra SP gains<br />

FDA clearance<br />

Mosaic receives<br />

CE mark<br />

US Headquarters<br />

opens<br />

Mosaic gains<br />

FDA clearance<br />

Accusculpt II<br />

receives CE mark<br />

Awarded<br />

Technology Fast500<br />

Selected as a member of<br />

‘Columbus Project’ by The<br />

Ministry of Health & Welfare<br />

of Korea<br />

Spectra new generation<br />

gains FDA clearance<br />

Healite II, Infini, Solari, &<br />

Claria recieve CE mark<br />

Infini gains KFDA clearance


<strong>Lutronic</strong> <strong>Systems</strong><br />

Each day thousands of physicians and patients place<br />

their trust in <strong>Lutronic</strong> medical devices.<br />

Your Clinical Needs Realized<br />

Physicians can count of the safety and efficacy of our systems.<br />

Patients can count of results that are predicable and reproducible.<br />

Efficacious<br />

First and foremost, <strong>Lutronic</strong> believes all our systems must be clinically sound and be<br />

backed by proven science and medicine. We invest strongly in our on-staff team of experts<br />

who partner with leading experts to perform clinical studies, research and ensure<br />

that our systems are efficacious. <strong>Lutronic</strong> systems have over 80 journal articles, which<br />

include more than 53 peer-reviewed articles, and the number is growing every day.<br />

SPECTRA<br />

Dual Mode Q-switched<br />

Nd:YAG <strong>Laser</strong><br />

Take your Practice to the Next Level<br />

<br />

melasma and tattoo removal<br />

<br />

<br />

<br />

Intuitive<br />

Our products, services and interfaces are consistent, easy to use and understand. Our<br />

intuitive systems allow physicians to concentrate on the patient, not the technology.<br />

From technology, interface to treatments our systems are built to be user-friendly.<br />

ADVANTAGE<br />

Diode <strong>Laser</strong><br />

Speed & Results Without Compromise<br />

<br />

<br />

<br />

<br />

Versatile<br />

Our systems are versatile; they all treat multiple applications and provide the widest<br />

range of treatment parameters. Physicians are confident that no matter what system<br />

they purchase they can offer their patients multiple treatments that are customized to<br />

their specific needs.<br />

eCO 2<br />

CO2 Fractional <strong>Laser</strong><br />

Versatile, Stable & Powerful Fractional Technology<br />

<br />

for improved patient comfort<br />

<br />

<br />

<br />

Reliable<br />

<strong>Lutronic</strong> systems are reliable; we believe it is important to work as promised from day<br />

one until you decide to upgrade. Our quality and reliability are what sets us apart;<br />

physicians can count on our systems to outlast and outperform, and when they do<br />

need servicing, our specialized technicians ensure that their system is up and running<br />

quickly.<br />

ACCUSCULPT II<br />

1444nm Pulsed Nd:YAG <strong>Laser</strong><br />

Precise Facial & Body Contouring<br />

<br />

<br />

<br />

<br />

Innovative<br />

We invest heavily in research and development, as well as partnering with leading<br />

experts in the medical and aesthetics fields to ensure that our systems are always cutting<br />

edge. Physicians can be sure that when they purchase a <strong>Lutronic</strong> device they are<br />

getting the latest technology has to offer.<br />

HEALITE II<br />

830nm LED Phototherapy System<br />

Advancing the Way to Faster Recovery


ACCUSCULPT<br />

PRECISE FACIAL & BODY CONTOURING<br />

1444nm Micropulsed Nd:YAG <strong>Laser</strong><br />

SPEED & RESULTS WITHOUT COMPROMISE<br />

Diode <strong>Laser</strong> Hair Removal and More<br />

ADVANTAGE<br />

AccuSculpt features unique 1444nm micropulsed Nd:YAG<br />

wavelength wavelength for facial and body contouring;<br />

(the clinical procedure is well known as the AccuLift .)<br />

The diversity of the device accommodates usage in both<br />

offices and hospitals while offering the following benefits:<br />

ACCURATE Lower thermal damage provides<br />

a safe and precise treatment.<br />

EFFECTIVE Ideal wavelength facilitates both<br />

efficient fat emulsification and skin contour-<br />

ing through collagen remodeling.<br />

IMPROVED Experienced physicians see less<br />

trauma to surrounding tissue and lower<br />

downtimes.<br />

INVISIBLE Small 18G needle incision for the<br />

600μm optical fiber, results in no scars, minimized<br />

discomfort, less bruising and minimal<br />

downtime.<br />

Advantage is a re-engineered, high energy pulsed<br />

diode laser system for hair removal and permanent hair<br />

reduction. This is the first laser system to integrate<br />

adjustable pulse width control with a large spot chilled<br />

compression tip. Built with speed, efficacy and comfort<br />

as the foundation, the Advantage is the cost-effective<br />

choice for a dependable laser hair removal system.<br />

QUICK Choice of large spot size provides<br />

up to 40% faster treatment rates.<br />

OPTIMIZED Wavelength ideally targets<br />

follicle, confining heat and minimizing<br />

lateral damage.<br />

UNLIMITED FDA cleared to treat Fitzpatrick<br />

skin types I-IV.<br />

FLEXIBLE Multiple treatment heads,<br />

treatment parameters and applications.<br />

Before<br />

After<br />

Before<br />

After<br />

Before<br />

After 6 mos<br />

Before<br />

After 6 mos<br />

Upper Arm<br />

Nasolabial Fold, Jowl, Submentum<br />

Underarm Hair<br />

Underarm Hair<br />

Courtesy of S. J. Baek, M.D., S. Korea<br />

Courtesy of J. David Holcomb, M.D., USA<br />

Courtesy of Wooseok Koh, M.D., Korea<br />

Courtesy of Wooseok Koh, M.D., Korea<br />

PERFORMANCE<br />

SYSTEM SPECIFICATIONS<br />

PERFORMANCE<br />

SYSTEM SPECIFICATIONS<br />

Wavelength<br />

1444nm<br />

Wavelength<br />

805nm diode laser<br />

Pulse energy<br />

Max. 300mJ<br />

Pulse width<br />

D1-800: 5-400ms<br />

D3-800: 30-400ms<br />

Transmission system<br />

600μm optical fiber, 4m length<br />

Handpiece & spot size<br />

D1-800: 10x10mm<br />

D3-800: 10x30mm<br />

Energy calibration<br />

Auto-calibration<br />

Fluence<br />

D1-800: 5 to 100 J/cm 2 D3-800: 5 to 35 J/cm 2<br />

Pulse width<br />

100 μsec (0.1ms)<br />

Repetition rate<br />

Up to 3 Hz<br />

Pulse rate<br />

5-40 Hz<br />

Comfort management<br />

Contact cooling (3˚C)<br />

Aiming beam<br />

Red visible laser diode<br />

Peak power<br />

2800 W Max.<br />

Power output<br />

12 W<br />

Display<br />

Touch screen (8” LCD)<br />

Memory<br />

User programmable<br />

Dimensions (mm)<br />

409 x 592 x 464 (W x L x H)<br />

Input power<br />

Single phase 220 VAC - 230 VAC, 50/60 Hz<br />

Weight<br />

35kg<br />

Dimensions (mm)<br />

295 x 656 x 910 (W x L x H)<br />

Optional accessories<br />

Fiber, cannula set, suction cannula set,<br />

inflitration cannula set


eCO 2<br />

VERSATILE, STABLE & POWERFUL FRACTIONAL TECHNOLOGY<br />

CO2 Fractional <strong>Laser</strong><br />

ADVANCING THE WAY TO FASTER RECOVERY<br />

830nm LED Phototherapy System<br />

HEALITE II<br />

eCO 2 from <strong>Lutronic</strong> is the new generation of CO 2<br />

fractional resurfacing lasers combining versatility and<br />

easy-to-use dual mode technology with the deep ablative<br />

properties of a CO 2 laser system.<br />

RESULTS Patented Controlled Chaos<br />

Technology (CCT) provides lower thermal<br />

damage, improved patient comfort and faster<br />

healing by limiting the heat generated with<br />

each scan.<br />

VARIETY State-of-the-art micro spot size<br />

tips, the eCO2 system provides multiple treatment<br />

modes, from the most superficial to the<br />

deepest fractional ablation, to achieve effects<br />

tailored to the individual patient and skin<br />

condition.<br />

SMART FEATURES A variety of smart features<br />

allow the eCO2 to stand out. From the ergonomic<br />

handpieces, CCT and a range of scan<br />

patterns to the easy-to-use GUI <strong>Lutronic</strong> is<br />

know for, the eCO2 system will fit easily into<br />

your practice.<br />

Low-Level Light Therapy (LLLT) with HEALITE II is the<br />

therapeutic use of incident light to photomodulate<br />

cellular function, relieving pain and stiffness in muscles<br />

and joints and increasing blood flow. HEALITE II harnesses<br />

the properties of 830/590 nm light via Light Emitting<br />

Diode (LED) technology, properly delivered and<br />

concentrated, treating effectively without possibility of<br />

physical trauma or thermal damage.<br />

ADVANCED The innovative technology<br />

behind the Healite II takes LED phototherapy<br />

to a whole new level, by combining<br />

patented photosequencing and Optical<br />

Lense Array Technology (OLAT) with<br />

multiple wavelengths.<br />

SOLUTION Use alone or as an adjunctive<br />

treatment, the Healite II offers your practice<br />

a solution to set you apart.<br />

EASY The safe and simple to operate<br />

system allows you to leave treatments<br />

to your support staff, freeing you up to<br />

perform other procedures.<br />

Before<br />

After<br />

Facial Scarring<br />

Courtesy of H. Harker, M.D., Columbia<br />

Before<br />

After<br />

Nasolabial Fold, Jowl, Submentum<br />

Courtesy of J. David Holcomb, M.D., USA<br />

Increased blood flow and deep penetration<br />

provide improved recovery for your patients.<br />

Adjustable head for large coverage or focused intensity.<br />

PERFORMANCE<br />

SYSTEM SPECIFICATIONS<br />

PERFORMANCE<br />

SYSTEM SPECIFICATIONS<br />

Wavelength<br />

10.6 μm<br />

Wavelength<br />

830nm/590nm<br />

Medium of transmission<br />

Sealed off CO2 RF module laser<br />

Type of lamp<br />

LED (Light Emitting Diode)<br />

Maximum power<br />

Scanner handpiece<br />

Maximum 30 Watt at Continuous Wave<br />

User Mode Static/Dynamic<br />

Pulse Energy 2mJ - 240mJ<br />

Pulse Rate 10Hz - 200Hz<br />

Density 25 - 400 spots/cm2<br />

Scan Area Max. 14 x 14mm<br />

Type & degree of protection<br />

against electrical shock<br />

Electrical rating<br />

Power comsumption<br />

User interface<br />

CLASS I/B type<br />

AC110-120V or AC220-230V, 50/60Hz, FUZE 250V/6.3A<br />

600VA<br />

3.2” touch LCD module<br />

Normal handpiece<br />

User Mode Char Free (Ultra Pulse)/Super Pulse/CW<br />

Pulse Rate Char Free (Ultra Pulse) 1Hz - 700Hz<br />

Super Pulse<br />

1Hz - 400Hz<br />

Pulse Width Char Free (Ultra Pulse) 40μs - 1,000μs<br />

Super Pulse<br />

1ms - 5ms<br />

CW ON time Cont, 0.01s - 1.0s<br />

OFF time Single, 0.01s - 1.0s<br />

Cooling system<br />

Power output<br />

Body dimensions (mm)<br />

Weight<br />

Cold air<br />

40-60mW/cm2<br />

Body: 556 x 671 x 1562 (W x L x H)<br />

Head: 510 x 300 x110 (W x L x H)<br />

27kg<br />

Dimensions (mm)<br />

360 x 450 x 1870 (W x L x H)


SPECTRA<br />

TAKE YOUR PRACTICE TO THE NEXT LEVEL<br />

Dual Mode Q-switched Nd:YAG <strong>Laser</strong><br />

SPECTRA has been engineered to meet the growing<br />

demands of a busy clinic, and includes a variety of efficacious<br />

treatment options, customizable parameters, built-in<br />

safety, minimized downtimes, all at an affordable price.<br />

OPTIONS Multiple laser modes and power<br />

settings maximize treatment options and<br />

allow you to provide customized treatments<br />

for every patient.<br />

TREATMENTS Provide your patients with a<br />

broad range of treatments including melasma<br />

and pigments, tattoo removal and more.<br />

RESULTS The power you need, the thermal<br />

damage you don’t, provide reproducible<br />

results and gentle treatments for broad range<br />

of skin types.<br />

PEACE OF MIND The ease-of-use you want<br />

combined with the peace of mind provided<br />

by this robust system.<br />

Continued Commitment<br />

to Clinical Excellence<br />

We continually strive for excellence and continue<br />

to partner with experts in their respective fields to<br />

conduct new studies, explore new applications, and<br />

refine and improve our systems. Our success only<br />

comes with your success.<br />

See what physicians doing with our technology:<br />

www.lutronic.com/media<br />

Before<br />

After<br />

Before<br />

After<br />

Supporting You Every<br />

Step of the Way<br />

Tattoo Removal<br />

Melasma<br />

Courtesy of Matthew Werner, M.D., USA<br />

Courtesy of Kevin Duplechain, M.D., USA<br />

PERFORMANCE<br />

Wavelength<br />

Operating mode<br />

Beam profile<br />

Pulse energy<br />

Energy calibration<br />

Pulse width<br />

Solid dye laser (option)<br />

Spot size (auto sensing)<br />

Aiming beam<br />

SYSTEM SPECIFICATIONS<br />

1064nm/532nm (Option: 585nm, 650nm)<br />

Q-switched mode & Spectra mode (Quasi-long Pulse)<br />

Top Hat mode<br />

1064 mode (Q-switched) Max. 1200 mJ<br />

532 mode (Q-switched) Max. 400 mJ<br />

Spectra mode (1064nm)<br />

Max. 1500 mJ<br />

585 mode Max. 250 mJ<br />

650 mode Max. 150 mJ<br />

External, Auto-calibration & self-restoration<br />

5-10ns (Q-switched mode) / 300μs (Spectra mode)<br />

585nm: 7.5J/cm 2 , 650nm: 4.5J/cm 2<br />

1064nm<br />

3, 4, 5, 6, 7, 8 mm/1, 2, 3, 4, 5, 6, 7 mm<br />

532nm<br />

2.6, 3.4, 4.3, 5.2, 6.0, 6.9 mm/<br />

0.8, 1.7, 2.6, 3.4, 4.3, 5.2, 6.0 mm<br />

585nm, 650nm 2mm<br />

Diode 655nm (red), adjustable brightness<br />

When you purchase a <strong>Lutronic</strong> product, you’ll enjoy the dedicated training support to help you achieve mastery of your new<br />

device. You can take comfort in the fact that if you ever need service, it’s a phone call away. Unlike other companies who drop<br />

you as soon as you make a purchase, <strong>Lutronic</strong> stays with you every step of the way. This includes helping you with the marketing<br />

support that helps drive patients into your practice and keeps them.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!