COMMERCIAL OIL MODELS<br />
CENTER AND REAR FLUE<br />
Rugged, durable and renowned for their high output, these models meet the<br />
highest standards in quality and dependability. <strong>Bradford</strong> <strong>White</strong> oil-powered<br />
water heaters include exceptional standard features that specifiers, installers,<br />
and cus<strong>to</strong>mers can depend on.<br />
APPLICATIONS:<br />
Small hotels and restaurants<br />
FEATURES:<br />
full descriptions are available in glossary beginning on page 33<br />
• Burners are UL Listed<br />
• Hydrojet ® Total Performance System<br />
• Vitraglas ® Lining<br />
• 70 Gallon Models<br />
• Flexible Stainless Steel Baffle (Center<br />
Flue Models Only)<br />
• Ceramic Fiber Combustion Chamber<br />
• Max Temp - 160˚F<br />
• NPT Dielectric Waterway Fittings–<br />
1" on Center Flue Models,<br />
1 1 ⁄4" on Center Rear Models<br />
• Low Restriction Brass Drain Valve<br />
• T&P Relief Valve Installed<br />
• Magnesium Anode Rod<br />
• 1" Non-CFC Foam Insulation<br />
(Fiberglass on RF-70-3)<br />
• 1-Year Limited Warranty on Parts and<br />
Burners<br />
• 3–Year Limited Tank Warranty– can be<br />
upgraded <strong>to</strong> 5–Year at additional cost<br />
Model<br />
Number<br />
CF-70-3<br />
RF-70-3<br />
Capacity<br />
U.S.<br />
Gal.<br />
70<br />
70<br />
Input<br />
BTU/Hr.<br />
119,000<br />
210,000/245,000<br />
Minimum<br />
Maximum<br />
Firing<br />
Rate<br />
GPH<br />
0.85<br />
1.50/1.75<br />
Recovery at<br />
100°F Rise<br />
U.S.<br />
GPH<br />
114<br />
203/237<br />
Floor <strong>to</strong><br />
Heater<br />
Top<br />
in.<br />
63 7 /16<br />
72 1 /16<br />
Jacket<br />
Dia.<br />
in.<br />
24<br />
28 1 /2<br />
Vent<br />
Size<br />
in.<br />
6<br />
8<br />
Approx.<br />
Shipping<br />
Weight<br />
lbs.<br />
290<br />
410<br />
CF = Center Flue<br />
RF = Rear Flue<br />
Part Number Description<br />
228-49641-03 Carlin burner with aquastat for CF-70-3 120V, 1 stage (0.85 gph)<br />
228-49641-07 Carlin burner with aquastat for RF-70-3 120V, 1 stage (1.50 gph)<br />
228-49641-18 Carlin burner with aquastat for RF-70-3 120V, 1 stage (1.75 gph)<br />
These models are not recommended for sanitation purposes.<br />
VISIT WWW.BRADFORDWHITE.COM FOR THE RIGHTSPEC ® SIZING AND CROSS REFERENCE PROGRAM.<br />