Environmental Dust Monitors<br />

ENVIRO<br />

ISO 9001 certified<br />

2011<br />

www.GRIMM-aerosol.com<br />

EXPERIENCE AND EXPERTISE<br />

SINCE 1981


The Future of Dust and<br />

Particle Monitoring<br />

Dear readers,<br />

I am delighted to find you interested in our Enviro Product Line.<br />

Measuring and assessing particulate matter within the<br />

ambient air is of prime importance: Limit values set by the<br />

World Health Organization (WHO) for human health<br />

protection are exceeded worldwide every single day.<br />

In highly congested urban areas in particular, the degree of<br />

contamination is clearly above those limit values with a serious<br />

impact on all those many people subjected to it. In contrast to<br />

gaseous airborne pollutants, no minimum threshold can be<br />

scientifically defined for fine dust beneath the size of which<br />

such dust does not have any further relevance to health. As a<br />

consequence, it is our duty and responsibility to reduce<br />

particulate matter contamination within the ambient air to a<br />

level that is both technically feasible and cost-efficient at the<br />

same time.<br />

For more than 20 years my work at the Institute for<br />

Environmental Protection of the Berlin Technical University<br />

focused on measuring and assessing airborne pollutants.<br />

Today, different measuring principles and techniques for the<br />

determination of atmospheric dust are used in research and in<br />

applications: gravimetric sampling (high-volume and lowvolume<br />

sampling), beta dust monitors, nephelometers,<br />

thermographic, electrostatic and optical methods. Each of<br />

these technologies has its advantages and disadvantages, as<br />

well as its specific range of applications.<br />

Over time, however, a lot has changed: The measuring tasks<br />

have become more demanding and consequently the<br />

requirements on the necessary measuring technology as well.<br />

If in the past monitoring was mainly about staying within dustrelated<br />

limit values; today, root cause analyses and finding the<br />

sources of fine dust contamination have become the primary<br />

targets. Only by being able to properly identify the source of a<br />

specific particulate matter contamination, appropriate, costefficient,<br />

and long-lasting, effective initiatives can be started in<br />

politics.<br />

It is not sufficient to learn tomorrow about today´s fine dust<br />

contamination values; people are entitled to get real-time<br />

information about the current fine dust contamination. In<br />

addition, mean values on a 24-hour basis do not offer enough<br />

information for a precise identification of the contamination<br />

sources.<br />

Atmospheric processes, such as vertical and horizontal<br />

transport and compound processes that have a fundamental<br />

influence on the fine dust contamination within the ambient<br />

air, obviously show lower time scales (minutes to seconds). As a<br />

consequence, measuring technologies with the following<br />

characteristics have become indispensible for today's<br />

measuring tasks:<br />

Dr. Markus Pesch<br />

Technical Director<br />

GRIMM Aerosol Technik GmbH<br />

Continuous measurements with a high temporal<br />

resolution (a few seconds up to 30 minutes)<br />

Information on the particle mass fractions PM10, PM2.5<br />

and PM1 (to monitor the current and future limit values).<br />

Determination of the particle size distribution (to judge its<br />

relevance to health and precisely identify the source).<br />

Maintenance-free, reliable measuring technologies<br />

involving little labor (cost-efficiency).<br />

High sensitivity and low levels of detection (reliable<br />

determination even at low dust contamination of but a few<br />

µg/m³).<br />

Our GRIMM optical fine dust measuring equipment was<br />

designed to meet all the above mentioned requirements.<br />

All our Enviro systems are equipped with the same optical<br />

chamber permitting a precise and reliable single particle<br />

determination. This optical chamber is currently operating in<br />

more than 3,000 devices worldwide and has proven its<br />

quality and superiority by successfully passing the European<br />

directives for PM10 and PM2.5. With the ability to<br />

simultaneously measure dust mass fractions PM10, PM2.5<br />

and PM1 as well as the particle size distribution in up to 31<br />

size channels (simply by switching measuring modes), the<br />

operator is well-prepared for all present and future dust<br />

measurement tasks and specific root cause analyses.<br />

In my capacity as Technical Director of the GRIMM company, I<br />

will strive for a continuous development of measurement<br />

technologies meeting the highest technical standards and<br />

setting the benchmark for what is possible today. Rest<br />

assured that through the combined know-how of our<br />

engineers and scientists - from the service department to the<br />

product development department to R&D - we will provide<br />

top quality in all aspects of our product range and services.<br />

Our line of Enviro products is currently employed in various<br />

fields of application worldwide. I look forward to welcoming<br />

you as a new future GRIMM customer.<br />

Yours truly,


GRIMM’s ENVIRONMENTAL DUST MONITORING FAMILY<br />

PM , PM , PM (or TSP), TC (total count) - all in real-time<br />

10 2.5 1<br />

Portable Enviro Check<br />

GRIMM EDM 107 & EDM 164<br />

(pages 6-7)<br />

The EDM 107 (shown on the right) is a small, portable unit measuring 24 x 12x6cm.<br />

Battery-operated it is possible to measure PM<br />

10, PM<br />

2.5, PM<br />

1<br />

(or Total Suspended<br />

Particles, TSP), and TC (Total Counts) simultaneously for up to 8 hours with a time<br />

resolution from 6 seconds on up.<br />

Next to it, you can see our EDM 164 outdoor housing with integrated heating to<br />

reduce humidity. This compact system has been designed for minimum<br />

maintenance.<br />

Mobile Professional Enviro Check<br />

GRIMM EDM 365<br />

(pages 12-13)<br />

With our EDM 365 we set new standards in environmental monitoring! Compared<br />

to the portable EDM 107 this stand-alone mini shelter can operate on a continuous<br />

basis providing the PM-values of all dust fractions - including semi-volatile<br />

compounds -, the GPS position, wind speed, wind direction, precipitation,<br />

temperature, and humidity. Even data on nano particles down to 25 nm (mean<br />

diameter and total counts) are available and indicative gas sensors can be added as<br />

well. All values are automatically transmitted to the data logger or to the www.<br />

Stationary Dust Monitor<br />

GRIMM EDM 180<br />

(pages 8-11)<br />

The EDM 180 Environmental Dust Monitor is a 19" rack-mounted instrument<br />

specifically designed for use inside protective housings in conformity with the<br />

existing EPA regulations for dust monitoring. As an option, this system can deliver<br />

up to 31 particle size channels within a time resolution of 6 seconds. No semivolatile<br />

compounds are lost in the process. Approved and officially certified it is the<br />

ideal solution for government use in PM monitoring.<br />

Wide Range System<br />

GRIMM EDM 665<br />

(pages 14-15)<br />

Flagship of our Enviro line is the Wide Range Aerosol System EDM 665, the ideal<br />

combination of optical and electrical mobility particle sizing. It has been designed for<br />

environmental research with a perfect overlap of both technologies in the measuring<br />

results. This system automatically determines the size distribution of all aerosols<br />

ranging from 5 nm to 30,000 nm in more than 70 different size channels. In addition,<br />

it is a stand-alone system with an automatic sample air dehumidification and<br />

moisture extraction system incorporated. Thanks to the integrated air conditioning<br />

providing uniform operating conditions, the system can be run unsupervised for<br />

extended time periods necessitating but one single minor intervention a month.<br />

Meteorological sensors as well as GPS and wireless transfer are optionally available.


Measuring Principle<br />

TSP<br />

PM 10<br />

AIR FLOW:<br />

This inlet was designed to meet the requirements defined<br />

at the Johannesburg convention. Sample air at a volume<br />

flow of 1.2 liter/minute is directly fed into the measuring<br />

cell by passing through a TSP (total suspended particles)<br />

head and the probe inlet.<br />

Thanks to this unique principle none of the GRIMM<br />

instruments need any size-selective sample inlets as do all<br />

other dust monitors on the market.<br />

OPTICAL SYSTEM:<br />

The sample air is then passing through the heart of the patented GRIMM spectrometer cell that has<br />

been designed as a single particle detection and counting system. As a consequence, we can<br />

guarantee that every single particle is measured by the instrument.<br />

PM 2.5<br />

PM 1<br />

TC<br />

COUNTS<br />

NANO<br />

Detector<br />

Measuring Principle<br />

Sample air<br />

Mirror<br />

PM CLASSIFICATIONS:<br />

SVC MONITORING:<br />

Aperture<br />

angle<br />

Light trap<br />

90° Scattering angle<br />

The optical system was optimized in such a way<br />

as to ensure that the refractive change (color) is<br />

negligible. Even in the nano size range the<br />

sensitivity across the size channels an excellent<br />

sensitivity is ensured.<br />

All particles (aerosol) passing through the measurement cell are classified by size distribution into 31<br />

channels. Based on this size distribution principle, we obtained the European Equivalence Approval<br />

for PM10 and PM2.5 as well as the US-EPA Approval for PM2.5.<br />

The required figures for PM 10, PM 2.5, as well as for the suggested PM1<br />

are arrived at by multiplying the<br />

obtained count concentrations with the corresponding specific density factors then to be added to the<br />

total masses of each PM channel. This is all done automatically by the instrument.<br />

One of the main problems in measuring ambient air is high humidity. To prevent moisture or small<br />

water droplets from being measured the probe is usually heated to minimize this effect. As an<br />

unwanted side effect, semi-volatile compounds such as nitrates, sulfates, etc. are vaporized before<br />

they can be measured.<br />

Instead of heating the probe, the GRIMM EDM isothermically extracts the humidity by dry air or Nafion<br />

tubes, a process patented by GRIMM. Scientists all over the world agree that the semi volatile<br />

compound (SVC) fraction normally produced by manmade processes (industrial areas, automotive,<br />

combustion, etc.), can amount to 20-50% of the total dust. In addition to the PM + PM + PM<br />

values, this contribution can be determined as an SVC fraction by a GRIMM EDM 365.<br />

10 2.5 1


Benefits of GRIMM EDM Monitors<br />

FOUR VALUES SIMULTANEOUSLY<br />

The GRIMM EDM 180 is the only commercially available fine dust monitoring unit in the world,<br />

approved for PM 10 & PM 2.5, capable of measuring PM 10, PM2.5 and PM1<br />

in µg/m³, as well as TC (total<br />

particles) in p/l at the same time. Measurement updates of all these values are provided in 60-<br />

second intervals and in combination with optionally available meterological sensors identifying the<br />

origin is facilitated, thus permitting a better risk assessment.<br />

LITTLE MAINTENANCE REQUIRED<br />

All GRIMM Environmental Dust Monitors are designed in such a way as to require as little<br />

maintenance as possible; a field system check with a foolproof test kit should be largely sufficient.<br />

ISO 9001 stipulates that calibration of the spectrometer of that system is calibrated once every 12 to<br />

18 months. Instead of calibrating several instruments - one for each PM value - there is but one<br />

GRIMM instrument needing calibration.<br />

REMOTE SERVICE, CONTROL & DATA ACCESS<br />

Output data from the instrument can be directly transmitted to your environmental network, your<br />

Intranet or the world wide web by using our Data Logger 1142.M5 (or the integrated German<br />

GESYTEC protocol).<br />

Scientists or environmental engineers thus gain access to the data from anywhere in the world via the<br />

WWW, by SMS or other data transfer system. Worldwide access to the service interface of our<br />

instrument for the purpose of preventive maintenance is possible as well. A fully automatic self-test<br />

and control system monitors the performance of the instrument and reports possible errors. All this<br />

results in a considerable reduction of the total cost of ownership!<br />

The GRIMM data web page (see page 15) gives every customer the chance to look into his<br />

measurement results in real time from anywhere.<br />

COMPACT SOLUTION<br />

Apart from the fact that our instruments needed to be designed to include all necessary accessories<br />

one of the major objectives was the minimization their dimensions.<br />

Focusing on arriving at the smallest possible instrument size while not compromising reliable<br />

measurements the instruments we can offer compact and handy solutions for your everyday work.<br />

4<br />

I<br />

N<br />

1<br />

NO RADIOACTIVE SOURCE<br />

All these instruments operate with lasers; therefore, no radioactive license is required. Transport,<br />

service and disposal of the products is no longer a problem.<br />

PM 10<br />

NO CONSUMABLES<br />

None of our Environmental line products requires any consumables, such as filters, filter bands or the<br />

like to be changed on a regular basis. This translates into reduced costs, fewer visits and a constant<br />

revalidation of the unit.<br />

PM 2.5<br />

PM 1<br />

LOW POWER CONSUMPTION<br />

Due to the small air flow, the power requirement is minimal! Save lots of money in the course of a<br />

year thanks to our use of small pumps, low laser power, etc.<br />

TC


GRIMM EDM 107<br />

Advantages<br />

Fully automatic<br />

Portable<br />

Handheld Dust Monitor<br />

Simultaneous measuring of PM<br />

10, PM<br />

2.5, PM1<br />

and TC (total counts)<br />

combined with gravimetric sampling (patented)<br />

3 different PM’s<br />

Particle size (opt.)<br />

Rel. humidity (opt.)<br />

Air temperature (opt.)<br />

Air pressure (opt.)<br />

Data logger card<br />

RS-232<br />

Front view with digital display<br />

Rear view with removable filter<br />

Battery-operated<br />

Applications<br />

Mobile monitoring<br />

Hot spot monitoring<br />

Tunnel test<br />

Public site monitor<br />

Source identification<br />

Handling Benefits<br />

of EDM 107<br />

Handheld unit<br />

Not critical to vibration<br />

No radioactive source<br />

Our smallest portable spectrometer is the EDM<br />

107 measuring 24 x 12 x 6 cm and weighing<br />

a mere 2.5 kg (battery included). Results are<br />

collected in 1-minute intervals and the data<br />

stored on the removable data logger card or<br />

shown online on a PC.<br />

Specifications EDM 107:<br />

Similar to our certified EDM 180 with respect to<br />

EN12341<br />

EN14907<br />

US-EPA<br />

GOST R<br />

Measuring principle:<br />

Laser light scattering (90°)<br />

Measurement results:<br />

0.25 to >32 µm/31 channels or<br />

TSP, PM10 and PM2.5<br />

or<br />

PM<br />

10, PM<br />

2.5, PM1<br />

and TC<br />

Particle concentration:<br />

1 to 2,000,000 particles/liter<br />

Data presentation:<br />

in intervals from 6 sec. to 1h<br />

Sampling system:<br />

47 mm PTFE filter<br />

3<br />

Dust mass: 0.1 to >6,000 µg/m<br />

Sample flow: 1.2 l/min, flow-controlled<br />

Reproducibility:3 % in max. range<br />

Power supply: 18 VDC<br />

Weight: 2.5 kg incl. lead battery<br />

Battery life: up to 8h of operation<br />

Temp. range: + 4°C to + 50°C<br />

47 mm filter holder<br />

Little maintenance<br />

Only 2.5 kg<br />

This picture (left) shows the EDM 107 integrated in<br />

our outdoor weather housing 165 and combined<br />

with a meteorological set, installed at a seaside<br />

location.


THE BEST IN PRICE & PERFORMANCE<br />

COMPACT<br />

EFFICIENT & RELIABLE<br />

NEW<br />

GRIMM EDM 164<br />

Portabe Industrial Enviro-Check<br />

EDM 164<br />

Model 164 is the combination of our efficient and reliable EN & US-EPA approved<br />

GRIMM light-scattering technology for aerosol monitoring with a smart<br />

dehumidification system.<br />

This system has been designed for maintenance-free long-term monitoring without<br />

any operator interaction. A combination with optional sensors for meteorology (wind<br />

speed, wind direction, humidity, temperature and precipitation) is optionally available.<br />

Data are available in real-time, stored in the internal memory and can be read out with<br />

the included PC software; alternatively, it can directly be uploaded to the world wide<br />

web in real-time via our Data Logger 1142.M5.<br />

Specifications EDM 107:<br />

Similar to our certified EDM 180 with respect to<br />

EN12341<br />

EN14907<br />

US-EPA<br />

GOST R<br />

Measuring principle: light scattering optics<br />

Measurement results: PM 10, PM 2.5, PM1<br />

and TC<br />

optional: 0.25 to >32 µm in 31 channels<br />

Particle concentration: 1 to 2,000,000 particles/liter<br />

Data presentation: in intervals from 6 sec. to 1h<br />

Data storage: internal storage<br />

3<br />

Dust mass:<br />

0.1 to >6,000 µg/m<br />

Sample flow:<br />

1.2 l/min, volume-controlled<br />

Reproducibility: 5 % in max. Range<br />

Software: GRIMM #177<br />

Specifications Housing:<br />

Housing:<br />

Sampling system:<br />

Winter protection:<br />

Dehumidification:<br />

Ventilation:<br />

Meteorology:<br />

Data logger:<br />

Security:<br />

Fixation:<br />

Power supply:<br />

optional:<br />

Temperature range:<br />

Dimensions:<br />

System weight:<br />

164 PM2.5 [µg/m³]<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

180 vs. 164, PM2.5, a = 0,005%, N = 1371<br />

y = 0,8431x - 0,1664<br />

R 2 = 0,957<br />

0 20 40 60 80 100<br />

180 PM2.5 [µg/m³]<br />

Glass fiber, gray<br />

0.5 m of pipe with<br />

TSP head<br />

Heating inside<br />

Heated sampling pipe<br />

Autom., proportional<br />

Optional<br />

Optional<br />

Double lock system<br />

Wall support hook<br />

110V/230 VAC,<br />

50-60 Hz<br />

12V - 32 VDC<br />

- 25°C to +50°C<br />

40 x 40 x 20 cm<br />

12 kg<br />

Advantages<br />

Fully automatic<br />

Portable<br />

3 different PM’s<br />

No radioactive source<br />

Not critical to vibration<br />

Little maintenance<br />

Extended memory<br />

DC power supply for solar<br />

panel or truck (optional)<br />

Particle size (optional)<br />

Meteorological sensors<br />

(optional)<br />

Data logger (optional)<br />

RS-232<br />

Applications<br />

Mobile monitoring<br />

Hot spot monitoring<br />

Public site monitor<br />

Source identification<br />

TSP<br />

PM 10<br />

PM 2.5<br />

PM 1<br />

TC<br />

COUNTS


GRIMM EDM180<br />

Advantages<br />

Fully automatic<br />

19” rack solution<br />

3 different PM’s<br />

Auto-dehumidification<br />

Particle size (optional)<br />

Relative humidity<br />

Air temperature<br />

Air pressure<br />

GESYTEC protocol<br />

Data logger system<br />

RS-232 port<br />

19” Rack Mounted Dust Monitor<br />

Stationary Approved Environmental Dust Monitor<br />

for the simultaneous measuring of PM , PM and PM<br />

The GRIMM EDM 180 has the capability to<br />

simultaneously measure PM10 and PM2.5<br />

values in<br />

real-time, and conforms to European standards<br />

EN 12341 for PM10 and EN 14907 for PM 2.5. Values<br />

for PM1<br />

and TC (total counts) are provided as well<br />

even though EN standards for those have yet to be<br />

established.<br />

Like a modular system, our EDM 180 can be<br />

delivered with one PM value determination only<br />

and subsequently be upgraded to deliver up to 3<br />

PM values and the total count; in addition, the<br />

complete particle count information from 0.25 µm<br />

to 32 µm can be made available in 31 size<br />

channels (refer to page 16).<br />

10 2.5 1<br />

Applications<br />

Enviro network<br />

Aerosol sizer<br />

Source identification<br />

Design Benefits<br />

EC approval for PM<br />

PM<br />

2.5<br />

equivalent<br />

PM fraction<br />

1<br />

10<br />

TC value<br />

All in one system<br />

No loss of SVC<br />

Service data access<br />

Not critical to vibration<br />

No radioactive source<br />

Little maintenance<br />

Auto retrack system<br />

Specifications EDM 180:<br />

Approved for:<br />

EN12341<br />

EN14907<br />

GOST R<br />

US-EPA (pending)<br />

Measuring principle:<br />

Laser light scattering (90°)<br />

Measurement reporting modes:<br />

EDM180-C: PM10 and PM2.5<br />

EDM180-CE: TSP and PM10<br />

EDM180-D: PM 10, PM 2.5, PM1<br />

and TC<br />

EDM180-E: 31 size channels from<br />

0.25 to >32 µm or<br />

Pm 10, PM 2.5, PM1<br />

and TC<br />

Particle concentration:<br />

1 to 2,000,000 p/l<br />

3<br />

Dust mass: 0.1 to >6,000 µg/m<br />

Sample flow: 72 l/h, flow-controlled<br />

Dehumidification:<br />

Autom. nafion dryer system<br />

Reproducibility:3 % in max. range<br />

Power supply: 230 V, 50 Hz/ 110 V, 60Hz<br />

Power<br />

consumption: 80W<br />

Size: 19”, 6HE


Approved Worldwide & Unrivaled<br />

Certifications and Approvals<br />

Worldwide approval and certification tests in the course of some 15<br />

years of field experience have put us in a position where today, we can<br />

exactly calculate the correct PM values in ambient conditions with an<br />

optical laser system.<br />

Today, this unique GRIMM EDM 180 is the only optical system to have<br />

passed environmental approvals for PM monitoring in accordance<br />

with gravimetric reference systems for PM as well as PM .<br />

GRIMM model EDM 180 is the only approved PM monitor<br />

worldwide providing PM and PM simultaneously in real-time.<br />

10 2.5<br />

10 2.5<br />

PM 10<br />

approved<br />

PM 2.5<br />

Correlation Slope Intercept


GRIMM EDM 180 Options<br />

NANO<br />

Model 1.320 NanoCheck Particle Sensor:<br />

With optically measuring technologies reaching their limit<br />

at some 150 nm, we developed the NanoCheck 1.320 to<br />

be used in combination with our EDM 180. This unit closes<br />

the gap down to 25 nm and provides information about<br />

the number and mean size of nano particles below the<br />

optical detection limit. It comes in a rack mounted version<br />

as depicted on the right.<br />

The upcoming 1. 321 NanoCheck<br />

Sensor will be able to<br />

monitor these nano particles in size ranges of 4 different<br />

classes.<br />

System 1.320/1.321 is a great add-on to the EDM 180 with an integrated 1142.M5 Data Logger and a<br />

touch panel. Get the benefit of being able to see ultrafine particle values in real-time on the display.<br />

Meteorology<br />

Sampling<br />

NEW Meteorological Sensors:<br />

Our new meteorological digital sensor program has now become available for<br />

the EDM 180/ 365/ 665 instruments as an option. It replaces the existing<br />

analogous sensors and upgrades the EDM 180 to benefit from this new digital<br />

technology<br />

Three versions are available:<br />

Model 157L for temperature, relative humidity and ambient pressure.<br />

Model<br />

158L adding wind speed and wind direction to the features of model 157L<br />

Model<br />

159L topping model 158L with an additional ultrasonic sensor for<br />

precipitation (rain and snow).<br />

Please note that apart from the 184L, sensors 158L and 159L require the 1142.M5 Data Logger as<br />

well. When upgrading from the standard analogous sensors, the 184L sensor connection kit is always<br />

required.<br />

Automated Filter Sampling:<br />

To obtain specific samples for laboratory testing (to determine the<br />

chemical composition for instance) of dust exceeding a certain value, we<br />

also supply intelligent filter sampling systems. Sampling time and<br />

sampling intervals are computer-controlled and can be set / modifed by<br />

the end user, which is true for the filter change of the 14 or more filters<br />

(25 to 47 mm).<br />

Another useful feature of the GRIMM instruments.<br />

NEW Outdoor Housings:<br />

To guarantee an accurate data acquisition in conformity with worldwide<br />

governmental regulations, we supply environmental 19" protective housings for our<br />

systems featuring integrated data acquisition systems and A/C. For detailed<br />

information ask for our GAS catalogue.


Calibration & Quality<br />

How are <strong>Grimm</strong> Aerosol instruments<br />

calibrated<br />

Each manufacturer calibrates his systems differently.<br />

Since no worldwide standard for the calibration of<br />

aerosol spectrometers exists, GRIMM developed their<br />

own in-house calibration process. This process has<br />

been validated by Government Departments and is<br />

based on a real-time comparison and adjustment<br />

between a “reference unit” and the unit to be<br />

Quality End Control<br />

<strong>Grimm</strong> Calibration Process<br />

Calibration between the candidate and the reference unit<br />

makes use of a "<strong>Grimm</strong> Calibration Tower" (shown on the<br />

left): The computer-controlled process itself is completely<br />

automated. Dolomite dust is used for our calibration aerosol.<br />

Dolomite dust is anoxic, not hygroscopic, polydisperse and<br />

very stable during storage. In addition, Dolomite dust covers<br />

the entire sizing range for all <strong>Grimm</strong> spectrometer from<br />

approx. 0.2 μm to >30μm. Due to the fact that both the<br />

reference unit and the candidate were manufactured<br />

identically, the Dolomite dust has to produce identical results<br />

in both spectrometers. The dust is injected at the top of the<br />

cylindrical calibration tower by particle-free compressed air<br />

and homogeneously dispersed within the entire tower. Up to<br />

three calibration candidates and one reference unit are<br />

attached to the bottom of the tower via identical aerosol<br />

inlets. A reverse flow of particle-free compressed air from the<br />

bottom to the top of the cylindrical tower guarantees a welldefined<br />

and reproducible aerosol particle distribution during<br />

the whole calibration process.<br />

All Enviro Systems are subjected to a long-term test by operating them complete with sampling pipe<br />

and weather housing (or outdoor rack) for a week in an outdoor reference system. During this time<br />

period, all functions are tested; humidity and temperature sensitivity of the probes, the humidity<br />

controlled mixing service or the temperature regulation, for instance. The data thus obtained are<br />

stored for each delivered unit.<br />

QUALITY<br />

100% Quality Control Control<br />

IS OUR<br />

Made in Germany<br />

DUTY<br />

Extended System Check


GRIMM EDM 365<br />

Advantages<br />

Fully automatic<br />

Outdoor stainless<br />

steel housing<br />

Housing with auto<br />

ventilation and heating<br />

3 different PM´s<br />

Auto dehumidification<br />

Particle size (opt.)<br />

Relative humidity<br />

Air temperature<br />

Air pressure<br />

GESYTEC protocol<br />

Data logger card<br />

RS-232 port<br />

Meteorology (opt.)<br />

Mobile Stand-Alone<br />

Environmental Monitoring Station<br />

For a simultaneous measuring of PM 10, PM2.5 and Pm 1 (or TSP) in real-time plus - optionally -<br />

rel. humidity, temperature, wind speed, wind direction, precipitation and atm. pressure<br />

All data are transferred online to the world wide web.<br />

GRIMM sets a new trend: instead of big<br />

measurement containers with cost-intensive<br />

maintenance requirements, our units are small<br />

and compact while making no compromises<br />

regarding dust and meterological demands.<br />

Our EDM 365 meets all demands and today,<br />

many of these stations are successfully operating<br />

in places all over the world and under the most<br />

adverse atmospheric conditions.<br />

Starting in 2011 we will offer devices of the next<br />

generation with additional gas sensors to<br />

permit the measurements of airborne gaseous<br />

pollutants (such as VOC, NOx, ozone, and CO),<br />

for better chemical differentiation.<br />

TC values<br />

Applications<br />

Enviro station<br />

Mobile PM monitoring<br />

Aerosol sizer<br />

Hot spot monitoring<br />

Source identification<br />

Construction Benefits<br />

Mobile housing<br />

No need for shelter<br />

All-in-one system<br />

Space for nano sensor<br />

Space for met. sensors<br />

Space for PAH sensor<br />

Not critical to vibration<br />

No radioactive source<br />

No loss of SVC<br />

Low maintenance<br />

Chemical analysis (opt.)<br />

Gravimetric analysis (opt.)<br />

Correlation of two different GRIMM instruments<br />

Specifications EDM 365:<br />

Equivalent to our certified EDM 180 complying<br />

with: EN12341 & EN14907<br />

US-EPA<br />

GOST R<br />

Measuring principle:<br />

Laser light scattering<br />

Measurement reporting modes:<br />

EDM 365-C: PM10 and PM2.5<br />

EDM 365-CE: TSP and PM10<br />

EDM 365-D: PM 10, PM 2.5, PM1<br />

and TC<br />

EDM 365-E: 31 size channels from<br />

0.25 to >32 µm or<br />

PM 10, PM 2.5, PM1<br />

and TC<br />

Particle concentration:<br />

1 to 2,000,000 particles/liter<br />

3<br />

Dust mass: 0.1 to >6,000 µg/m<br />

Sample flow: 72 l/h, flow-controlled<br />

Dehumidification:<br />

Automatic nafion dryer system<br />

Reproducibility:3 % in max. range<br />

Power supply: 230 VAC, 50 Hz<br />

(Optional: 110 VAC, 60 Hz)<br />

Dimensions:<br />

80 x 60 x 40 cm<br />

Weight: 25 kg<br />

Temp. range: - 25°C to + 50°C


EDM 365 Features and Options<br />

Size: 10 x 10 x 4cm<br />

1142.M5 Data Logger System<br />

The EDM 365 series comes with an integrated data<br />

logger system. This logger combines the information<br />

from the GRIMM dust monitor with other integrated<br />

sensors.<br />

This all-in-one microcomputer interface features an<br />

integrated web server, facilitating customer interaction<br />

with the instrument on the basis of TCP/IP protocols.<br />

TSP<br />

PM 10<br />

Digital Meteorological Sensors<br />

Our new digital meteorological sensor program is now available for all GRIMM<br />

EDM systems and has already become a standard in the EDM 365 product<br />

range. This 158L model delivers information on temperature, relative humidity,<br />

pressure, wind speed and wind direction.<br />

The optional model #159L combines the features of the #158L with a ultra sonic<br />

sensor for rain and snow information.<br />

1.320 NanoCheck Sensor<br />

Since optical measuring technologies reach their limit<br />

with particle diameters of less than 150 nm, we<br />

developed our NanoCheck 1.320: A device closing<br />

this gap down to 25 nm and providing information on<br />

the number and mean size of these nano particles.<br />

The combination of our optical spectrometer with the<br />

NanoCheck delivers additional information on<br />

ultrafine aerosols (soot particles from vehicle<br />

emissions, for instance) and mechanically created<br />

aerosols (such as tire and brake abrasion). AS a<br />

consequence, the NanoCheck add-on in<br />

combination with the EDM 365 represents the perfect<br />

tool for assessing air quality at road sites. Just think of<br />

the “Green Zones” currently set up all over the world,<br />

which can now be properly evaluated by such an<br />

instrument combination.<br />

365 Gas Sensors<br />

This indicative sensor was recently added to the GRIMM<br />

product portfolio to give customers the opportunity of<br />

acquiring an even more extensive environmental monitoring<br />

system.<br />

The gas system can be equipped with 2 different toxic gas<br />

detectors (CO, H2S, So2, NoX or Nh2) as well as a PID<br />

sensor. This sensor can be linked with the above data logger<br />

system to the EDM365.<br />

PM 2.5<br />

PM 1<br />

TC<br />

COUNTS<br />

NANO<br />

Meteorology<br />

GAS<br />

PAH


GRIMM EDM 665<br />

System components<br />

19” GRIMM Optical Particle<br />

Counter with 31 size<br />

channels<br />

19” GRIMM CPC<br />

Condensation Particle<br />

Counter with included<br />

M-DMA (Vienna Type)<br />

and 44 size channels<br />

Sampling probe with<br />

isothermal dehumidification<br />

(no heating)<br />

Shelter<br />

outdoor housing with<br />

air-conditioning system<br />

Highlights<br />

Counts all particles from<br />

5.5 nm up to 32 µm<br />

71 size classes<br />

Concentration<br />

1 to 10 particles/cm<br />

7 3<br />

Stand-alone measurement<br />

Fully automatic<br />

19” rack mounted<br />

instruments<br />

Unsupervised operation for<br />

extended periods of time<br />

Applications<br />

Environmental studies<br />

Aerosol research<br />

Mobile aerosol studies<br />

Roadside monitoring<br />

Engine exhaust studies<br />

Health effect studies<br />

Atmospheric Research Outdoor<br />

Wide Range Aerosol Spectrometer<br />

Main specifications EDM 665:<br />

Measurement range<br />

- 71 size channels<br />

from 5.5 nm up to 32 µm<br />

- Minimum scan time of 300 seconds<br />

- Concentration range from 1 to 10 P/cm<br />

7 3<br />

Optical device<br />

- Size range: 250 nm to 32 µm<br />

31 size channels<br />

- Particle counts: 1 to 2,000,000 P/liter<br />

- Sample flow: 1.2 l/min<br />

- Reproducibility: 3% in max. range<br />

SMPS+C device<br />

- Size range: 5.5 nm to 350 nm<br />

40 size channels<br />

- Particle counts:<br />

7 3<br />

0 to 10 P/cm<br />

- Sample flow: 0.3 l/min<br />

- Auto refill: Butanol refill of internal<br />

tank simply by connecting<br />

the bottle<br />

- Condensate<br />

removal:<br />

Continuous evacuation by<br />

micro-pump into a collecting<br />

flask<br />

Communication ports<br />

- integrated Microcomputer for data<br />

acquisition<br />

- integrated GRIMM data logger 1142.M5<br />

- 2 x RS-232 with 9-pin D connector<br />

- 2 x PCMCIA-slots for memory card use<br />

- Digital inputs for meteorological or gas<br />

sensors<br />

Operating conditions<br />

- Ambient temp.: -20°C up to +55°C<br />

- Power supply : 110/220 VAC, 50/60 Hz<br />

- Power consumption: 750 W<br />

Flagship of the GRIMM Enviro line - the<br />

EDM 665 Wide Range Aerosol System.<br />

This unique combination of optical and<br />

electrical mobility particle sizing<br />

technologies ideally supports environmental<br />

research in an extremely wide<br />

range of average particle diameters<br />

from 5 nm to 30,000 nm.<br />

Examples of obtained data<br />

Dimensions & Weight incl. A/C<br />

- Size: 60 x 60 x 120 cm<br />

- Weight: 120 kg<br />

- Sample pipe: 1.5 m (3 m optionally avail.)


Data Acquisition<br />

1142.M5 Data Logger<br />

Logger 1142.M5. This data logger is an all-in-one microcomputer<br />

interface with integrated web server permitting an interactive<br />

communication with the instrument based on TCP/IP protocols.<br />

This logger can be combined with all GRIMM products adding the following features to our<br />

instruments:<br />

Extended storage of up to 4 GB, remote control, the possibility to combine information from GRIMM<br />

monitors with data from various other sensors such as meteorology and gas probes. Data can be<br />

transmitted in real-time to the world wide web, our GRIMM data base system, your web page or an<br />

Intranet.<br />

The GRIMM database system offers a range of possibilities for the remote administration and<br />

configuration of your instrument from wherever you are and the data thus obtained can be presented<br />

Online<br />

Real Time<br />

Charts<br />

Tables<br />

Data Tables export<br />

Count values<br />

Measurement results online in real time<br />

PM values<br />

Tables GPS<br />

Google TablesMaps<br />

Remote<br />

Control<br />

Google map, GPS position and instrument status.<br />

Terminal feature for remote access of the instrument<br />

online switch between PM and count mode<br />

User<br />

management<br />

Integrated function for automatic instrument control,<br />

data export and management by the press of a button<br />

Download software<br />

demo for free trial


DATA PRESENTATION<br />

The GRIMM software programs for environmental measurement instruments can present all data<br />

obtained from the instrument itself (or via logger) numerically and graphically or as a histogram. Data<br />

export functions to different file types, MS Excel export, different print functions as well as instrument<br />

configuration tools are implemented.<br />

Examples of results sorted by the different EDM Model versions are shown in the below graphs to give<br />

you an impression of the possibilities to present data from the GRIMM Dust Monitors.<br />

TSP<br />

PM 10<br />

PM 2.5<br />

GRIMM EDM Model Type A - PM 10<br />

GRIMM EDM Model Type B - PM 2.5<br />

PM 1<br />

TC<br />

GRIMM EDM Model Type C<br />

PM & PM<br />

10 2.5<br />

GRIMM EDM Model Type D<br />

PM , PM , PM & TC<br />

10 2.5 1<br />

COUNTS<br />

NANO<br />

GRIMM EDM Model Type E<br />

31 size channels and reversable PM fractions<br />

GRIMM EDM Meteorological Data<br />

METEOROLOGY<br />

Our GRIMM TEAM is traveling all around the world to<br />

advise customers the best available solution in DUST<br />

Monitoring.<br />

FOR YOUR NEAREST EXHIBITION, ROAD SHOW OR<br />

SYMPOSIA VISIT OUR WEB OR CONTACT US.<br />

www.GRIMM-aerosol.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!