Power Supplies<br />

STANDARD FEATURES<br />

• UL294 Listed for <strong>Access</strong> Control<br />

• Class 2 rated power limited output<br />

• Universal 110-2<strong>20</strong> VAC input<br />

• Regulated and filtered DC outputs<br />

• AC input, battery and DC output LED indications<br />

• 1 connector for optional distribution boards<br />

• AC input status indication on outside cover<br />

• AC monitoring<br />

• 2" H x 14" W x 4" D enclosure<br />

1. Select Power Supply<br />

Model No. Description List Price<br />

PS902 Base Power Supply (2A @ 12/24 VDC field selectable) (approx. weight 9 lbs) 189<br />

PS902 is able to accept a total of 1 optional distribution board and 1 900-FA board<br />

PS914 Base Power Supply (4A (16A inrush) @ 12/24 VDC field selectable) (approx. weight 9 lbs) 534<br />

PS914 is able to accept a total of 2 optional distribution boards and 2 900-FA boards<br />

BAA "Buy America Act" compliant power supply option 29<br />

will be labeled as "Assembled in the U.S.A. with U.S. and foreign materials<br />

When specifying PS914 power supply for use with "EL" or "QEL" Electric Latch Retraction devices, the 2RS is furnished<br />

when board option not specified.<br />

2. Select Optional Distribution Board with or without FA (Fire Alarm Relay)<br />

Model No. Description Part # List Price<br />

900-4R Independently controlled relays 44489912-00 126<br />

900-4R-FA Independently controlled relays with FA 171<br />

900-2RS 2 Relay board output 44489896-00 <strong>13</strong>1<br />

900-2RS-FA 2 Relay board output with FA 176<br />

* For field installation, use model number. Example: 900-2RS.<br />

900-4RL 4 Relay board integrated logic for controlling security interlocks, 444899<strong>20</strong>-00 346<br />

auto operators and time delays<br />

900-4RL-FA 4 Relay board integrated logic for controlling security interlocks, 391<br />

auto operators and time delays with FA<br />

900-8F 8 fuse protected outputs 44489946-00 45<br />

900-8F-FA 8 fuse protected outputs with FA 90<br />

900-8P 8 PTC protected outputs 44489938-00 45<br />

900-8P-FA 8 PTC protected outputs with FA 90<br />

900-BBK Battery Backup Kit (includes two 7A/hr batteries) 44489961-00 180<br />

900-BB Battery Backup Board Only 44489953-00 90<br />

900-BAT Batteries Only (qty 2) 44487155-00 90<br />

3. Select Other Power Supply Options<br />

Model No. Description Part # List Price<br />

900-FA Fire Alarm Relay (EIR) module is a plug-in relay to provide an interface with 44487247-00 45<br />

fire or other emergency override systems<br />

PS902: may be installed directly on power supply or may be used with<br />

optional distribution boards<br />

PS914: must be used with optional distribution boards. If an optional<br />

board is not listed the 900-8F-FA will be provided.<br />

900-KL Key Lock Cover (not available with BAA) 44486850-00 29<br />

Note: PS902 and PS914 power supplies require connection to AC line voltage. Installation and all electrical<br />

connections (high and low voltage) should be performed by a qualified electrical contractor.<br />

Prices subject to change without notice<br />

Exit-55 Price Book <strong><strong>20</strong><strong>13</strong></strong>B • Effective July 1, <strong><strong>20</strong><strong>13</strong></strong> • Rev. 7/<strong>13</strong>