DEWE-50-USB2-8_broch.. - Dewetron America
DEWE-50-USB2-8_broch.. - Dewetron America
DEWE-50-USB2-8_broch.. - Dewetron America
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Automotive<br />
Energy & power Analysis<br />
Aerospace & Defense<br />
Transportation<br />
General Test & Measurement<br />
<strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
Modular USB data acquisition system for isolated signal conditioners<br />
When connected to the high speed USB 2.0 interface of<br />
any computer the <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8 becomes a powerful<br />
measurement instrument for analog, digital, counter<br />
and CAn-bus data capture. Simply connect a webcam<br />
to your computer and add video information to your<br />
recorded data.<br />
Eight simultaneous analog inputs sample data at up<br />
to 204.8 kS/s and in combination with DAQp-series<br />
isolated signal conditioners almost any sensor can be<br />
connected.<br />
popular measurands are:<br />
voltage Strain<br />
Current Acceleration<br />
Force Torque<br />
pressure Sound<br />
position RpM<br />
Frequency velocity<br />
Resistance And more<br />
The included <strong>DEWE</strong>Soft application software adds<br />
powerful measurement and analysis capability, turning<br />
the <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8 into a dedicated recorder, scope,<br />
data logger or FFT analyzer.<br />
The isolated signal conditioners make this unit almost<br />
indestructible and a safe investment for many years.<br />
Key Features<br />
Connects to any computer via USB interface<br />
8 slots for isolated DAQp-series signal<br />
conditioners<br />
24 bit resolution, 204.8 kS/s per channel<br />
Simultaneous sampling, separate ADC per channel<br />
2 counters or 6 digital inputs<br />
2 high speed CAn interfaces<br />
EpAD2 expansion for slow signals<br />
<strong>DEWE</strong>Soft instrument software included<br />
The <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8 is the perfect fit for<br />
Mobile applications<br />
e.g. mobile shock and vibration tests<br />
Field service<br />
e.g. bringing into service tasks<br />
Maintenance<br />
e.g. order tracking<br />
in-vehicle tests<br />
e.g. trouble shooting, OBDii data recording<br />
industrial applications<br />
e.g. balancing<br />
www.dewetron.com<br />
AUTOMOTivE<br />
pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
1
pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
2<br />
Connectivity<br />
USB and SYnC interfaces<br />
The USB connection to a host computer is secured with<br />
a unique mini-USB connector which actually screws into<br />
the backside of the <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8, locking it in place,<br />
and guarding against accidental disconnection.<br />
For channel expansion up to 16 analog inputs a second<br />
<strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8 can directly be attached to the unit,<br />
USB and SYnC interfaces are prepared.<br />
EpAD<br />
Analog input<br />
There are eight slots for DAQp series isolated signal<br />
conditioners. The internal A/D system offers eight analog<br />
inputs, each has its own sigma-delta A/D converter and is<br />
sampled at up to 204.8 kS/s at 24 bit resolution. Anti-aliasing<br />
filters are included for each channel.<br />
<strong>DEWE</strong>TROn offers a wide range of DAQp modules, see pages<br />
6 and 7 for an overview.<br />
To enable signal conditioning for additional slow signals an EpAD interface is prepared. <strong>DEWE</strong>TROn EpAD2 series<br />
modules to acquire quasi-static thermocouple, RTD, voltage or current signals can be connected to this interface by<br />
a single cable. The sampling rate of an EpAD2 input channel is approx. 10 Hz / amount of modules.<br />
CAn<br />
There are two high speed CAn interfaces which are able to acquire data from vehicle CAn – or vehicle OBDii<br />
interface – as well as from any sensor outputting CAn data.<br />
Additionally <strong>DEWE</strong>TROn CpAD2 modules can be connected to a CAn interface. These modules have the same<br />
features as EpAD2 but the sampling rate does not depend on the amount of attached modules, so it can be 10 Hz<br />
in any case.<br />
Option <strong>50</strong>-8-OUT-5<br />
Optional eight BnC sockets can be installed to provide access to the conditioned ±5 v signal of each DAQp<br />
module.<br />
www.dewetron.com
Counter input features<br />
<strong>DEWE</strong>TROn has advanced the state-of-the-art in<br />
counter/encoder inputs in our data acquisition<br />
systems.<br />
The key advancement is that our counters<br />
are pHASE SYnCHROniZED. Referring to the<br />
diagram, you can see that a standard counter<br />
is always a sample behind. With software<br />
interpolation you can get closer, but only with<br />
<strong>DEWE</strong>TROn’s advanced time shifting technology<br />
are both the phase and amplitude fully<br />
corrected!<br />
RPM-Measurement<br />
Length-measurement<br />
Event Counting<br />
Waveform Timing<br />
Encoder<br />
Tacho<br />
Gearthooth, CDM<br />
ADC-clock<br />
Counter input<br />
ideal counting<br />
ORION-counter<br />
Software interpolation<br />
Standard counter<br />
Gearthooth, TRG, CDM and TRG<br />
Gearthooth with missing teeth<br />
Gearthooth with double teeth<br />
Linear encoder<br />
Linear pulse sensor<br />
Basic counting<br />
Gated counting<br />
Up/down counting<br />
period frequency<br />
Two pulse edge separation<br />
period, pulse width,<br />
frequency, duty cycle<br />
PORTaBLE INSTRUMENTS • <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
3
pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
4<br />
<strong>DEWE</strong>Soft<br />
Our award-winning data acquisition package is second to none when it comes to both pure recording power and<br />
ease of use. normally it is a difficult balancing act to provide lots of capability and performance, without making the<br />
user interface cumbersome and hard to learn. But with careful and innovative design, we have done exactly that!<br />
<strong>DEWE</strong>Soft is the solution to acquire signals synchronous from different sources, display and store them together<br />
and perform quick analyses.<br />
File browser in analyze mode<br />
Typical <strong>DEWE</strong>Soft report<br />
Typical <strong>DEWE</strong>Soft online display<br />
Key Features<br />
perfect sync of analog, digital, counter, CAn, GpS,<br />
video, ARinC, 1553 data … and even more<br />
Fast and easy setup of all kinds of input channels<br />
Failsafe and simple sensor setup by TEDS or<br />
sensor database<br />
powerful online data processing, MATH functions,<br />
filters, statistics, reference curves<br />
Attractive online display of all kind of data,<br />
creation of displays is a matter of seconds<br />
various storing strategies, stream data to hard<br />
disk (up to 100 MB/s), triggered storing or<br />
database storing<br />
Analog, digital or CAn data output, powerful<br />
function generator, alarms, CAn messages<br />
Build test procedures in a form of workflow<br />
diagram by means of our sequencer<br />
Fast data analysis, reload GB files in seconds<br />
post processing, a data file can be postprocessed<br />
on any computer<br />
Ready to us applications, power calculations,<br />
Combustion analysis, Torsional vibration, Order<br />
tracking, Sound analysis, Frequency response<br />
function, Human vibrations, Balancing ... and even<br />
more<br />
www.dewetron.com
SPECIFICaTIONS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
aNaLOG INPUT<br />
number of channels 8 (simultaneously sampled)<br />
Measured values According installed DAQp modules<br />
INTERNaL a/D SySTEM<br />
Resolution 24 bit<br />
Type of ADC Sigma-Delta<br />
Sampling rate 204.8 kS/s<br />
-3 dB bandwidth 76 kHz @ 204.8 kS/s<br />
(consider possible limit of DAQp module)<br />
Accuracy ±0.1 % of range, ±0.5 mv<br />
DyNaMIC CHaRaCTERISTICS<br />
Signal to noise @ fs
pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
6<br />
Selection guide<br />
DAQ series modules<br />
Single channel<br />
High bandwidth - for dynamic signals<br />
isolation (most models)<br />
Analog signal output (±5 v)<br />
Single channel modularity<br />
Module Input type Ranges TEDS<br />
Universal measurement<br />
Bandwidth (BW),<br />
Filters (LP = lowpass,<br />
HP = highpass)<br />
Isolation (ISO),<br />
Overvoltage<br />
protection (OP)<br />
DAQP-STG Strain gauge, bridge sensors ±0.1 to ±1000 mV/V (@ 5 VDCexc) ■ BW: 300 kHz ISO: 3<strong>50</strong> VDC<br />
Piezoresistive bridge ±0.5 to 10000 mV/mA (@ 1 mAexc) LP: 10 Hz to 300 kHz OP: ±<strong>50</strong> VDC<br />
Voltage<br />
Resistance<br />
±<strong>50</strong>0 µV to ±10 V<br />
25 mΩ to 100 kΩ<br />
Pt100, Pt200, Pt<strong>50</strong>0, Pt1000,<br />
Pt2000<br />
-200° C to 8<strong>50</strong>° C<br />
IEPE ® V<br />
via MSI-BR-ACC<br />
±2.5 to ±10000 mV<br />
MSI MSI MSI<br />
Thermocouple via MSI-BR-TH-x full range of TC type<br />
Charge via MSI-BR-CH-<strong>50</strong> up to <strong>50</strong>000 pC<br />
Voltage via MSI-BR-V-200 up to ±200 V<br />
High voltage measurement<br />
DAQP-HV High voltage ±20 to ±1400 V - BW: 300 kHz ISO: 1.8 kVRMS<br />
LP: 10 Hz to 300 kHz<br />
V<br />
DAQP-HV-S3 High voltage ±20 to ±1400 V - BW: 700 kHz ISO: 1.8 kVRMS<br />
LP: 10 Hz to 700 kHz<br />
V<br />
DAQP-DMM High voltage ±10 to ±1000 V - BW: 20/30 kHz ISO: 1.5 kVRMS<br />
LP: 10 Hz to 30 kHz<br />
V<br />
Voltage & current measurement<br />
DAQP-LV Voltage ±10 mV to ±<strong>50</strong> V ■ BW: 300 kHz ISO: up to 1 kVRMS<br />
Current with external shunt 20 mA / 5 A LP: 10 Hz to 300 kHz OP: 3<strong>50</strong> VDC<br />
IEPE ® via MSI-V-ACC<br />
±10 mV to 10 V<br />
V<br />
MSI MSI<br />
Pt100, Pt200, Pt<strong>50</strong>0, Pt1000, -200° C to 1000° C and<br />
Pt2000 and resistance via 0 to 6.5 kOhm<br />
MSI-V-RTD<br />
Charge via MSI-V-CH-<strong>50</strong> up to <strong>50</strong>000 pC<br />
DAQP-V Voltage 10 mV to <strong>50</strong> V - BW: <strong>50</strong> kHz ISO: up to 1 kVRMS<br />
Current with external shunt 20 mA / 5 A LP: 10 Hz to <strong>50</strong> kHz OP: ±<strong>50</strong>0 VDC<br />
V<br />
DAQN-AIN Voltage ±10 V (1:1 input) - - OP: < ±<strong>50</strong>0 V<br />
(jumper<br />
selectable)<br />
V<br />
Current measurement<br />
MSI<br />
DAQP-LA-SC Current 0.1 A to 30 A peak - BW: 300 kHz ISO: 1.4 kVRMS<br />
Note: 5 ARMS continuous max. 5 ARMS contin. current LP: 10 Hz to 300 kHz<br />
DAQP-LA-B Current 2 mA to 600 mA - BW: 300 kHz ISO: 1.4 kVRMS<br />
Note: typ. 20 mA application LP: 10 Hz to 300 kHz<br />
www.dewetron.com<br />
■ = standard
Module Input type Ranges TEDS<br />
Bridge / strain gauge and carrier frequency amplifier<br />
OUT<br />
Bandwidth (BW),<br />
Filters (LP = lowpass,<br />
HP = highpass)<br />
Isolation (ISO),<br />
Overvoltage<br />
protection (OP)<br />
DAQP-CFB AC bridge, strain gauge Bridge: 0.1 to 1000 mV/V - BW: DC to 2.3 kHz OP: ±10 VDC<br />
Note : 5 kHz sine wave excitation LP: 10 Hz to 1 kHz<br />
Inductive sensors, LVDT Inductive: 5 to 1000 mV/V<br />
DAQP-BRIDGE-A Strain gauge, bridge sensors ±1 to ±<strong>50</strong> mV/V (@ 5 VDC) - BW: 20 kHz ISO: 3<strong>50</strong> VDC<br />
LP: 10 Hz to 20 kHz OP: ±10 VDC<br />
Potentiometric sensors 200 Ω to 10 kΩ<br />
DAQP-BRIDGE-B Strain gauge, bridge sensors ±0.1 to ±100 mV/V (@ 5 VDC) ■ 1) BW: 200 kHz OP: ±10 VDC<br />
LP: 10 Hz to 200 kHz<br />
Charge / IEPE ® measurement<br />
Potentiometric sensors 200 Ω to 10 kΩ<br />
DAQP-ACC-A IEPE ® sensors ±<strong>50</strong> mV to ±5 V - BW: 0.5 Hz to 300 kHz -<br />
LP: 1 to 300 kHz<br />
HP: 0.5 Hz and 5 Hz<br />
DAQP-CHARGE-A Charge sensors Charge: 5 to <strong>50</strong>000 pC - BW: 0.1 Hz to <strong>50</strong> kHz -<br />
IEPE ® sensors IEPE ® : ±5 mV to 5 V LP: 100 Hz to <strong>50</strong> kHz<br />
Note: selectable integration and<br />
double integration<br />
HP: 0.1 Hz to 10 Hz<br />
DAQP-CHARGE-B Charge sensors ±100 to ±1 000 000 pC - BW: DC to 100 kHz ISO: 3<strong>50</strong> VDC<br />
Temperature measurement<br />
LP: 10 Hz to 100 kHz<br />
Note: selectable time constant HP: DC, 0.001 Hz to 0.5 Hz<br />
for static sensors<br />
DAQN-THERM-x Thermocouple K and J type (others on request) - BW: 4 Hz ISO: 1 kVRMS<br />
DAQN-THERM-1 K: -30 to 170 °C<br />
Note: internal CJC DAQN-THERM-2 K: -30 to 370 °C<br />
DAQN-THERM-3 K: 0 to 1000 °C<br />
DAQN-THERM-4 K: -100 to 13<strong>50</strong> °C<br />
DAQN-THERM-5 J: -100 to 760 °C<br />
DAQN-RTD-x Thermoresistors Pt100 - BW: 10 Hz -<br />
DAQN-RTD-1: -30 to 170 °C<br />
DAQN-RTD-2: -100 to 200 °C<br />
DAQN-RTD-3: -<strong>50</strong> to 600 °C<br />
Frequency measurement<br />
DAQP-FREQ-A Frequency 100 Hz to 200 kHz - BW: according to range<br />
Output response:<br />
1.5 ms<br />
30 ms<br />
<strong>50</strong>0 ms<br />
ISO: 3<strong>50</strong> VDC<br />
Voltage output module<br />
DAQN-V-OUT Voltage output 1:1 output module with isolation - BW: 400 Hz ISO: 240 VDC<br />
Input voltage: ±10 V<br />
Output voltage: ±10 V<br />
1) TEDS support for DAQP-BRIDGE-B revision 2 only ■ = standard<br />
ADAp-D9M-BnCF:<br />
DSUB to BnC adapter<br />
for DAQp-v series and<br />
DAQp-FREQ modules<br />
BnC to Microdot adapter<br />
(included as a standard with<br />
DAQp-CHARGE-A modules)<br />
COnn-DSUB-9:<br />
Screw terminal adapter<br />
for all modules with 9-pin<br />
DSUB connector<br />
BnC to banana and<br />
banana to BnC adaptors<br />
isolated high-voltage amplifier:<br />
DAQp-Hv<br />
PORTaBLE INSTRUMENTS • <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
7
pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />
8<br />
applications<br />
Recorder<br />
Synchronous recording of different signals<br />
voltage Acceleration<br />
pressure Force<br />
Temperature Sound<br />
position RpM<br />
Torque Frequency<br />
velocity And more<br />
Torsional and Rotational vibration<br />
Time domain measurement<br />
Angle based view<br />
Additional to all other functions (analog, CAn, GpS, video, ...)<br />
Configurable display<br />
Direct sensor connection<br />
80 MHz time base<br />
High resolution ±0.03rpm ±2 mdeg@12000 rpm<br />
The shown applications are only a few examples, many more can be covered using<br />
the <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8 instrument.<br />
<strong>DEWE</strong>TRON Ges.m.b.H. • Parkring 4 • A-8074 Graz-Grambach<br />
Tel (0043) 316 3070 0 • Fax (0043) 316 3070 90 • sales@dewetron.com<br />
Order Tracking<br />
Dedicated re-sampling method for sharp order separation<br />
Measurement in time domain to keep all benefits<br />
2D, 3D waterfall in order or frequency domain<br />
Amplitude, phase extraction<br />
Recalculation in post processing<br />
phase synchronous RpM input with 12.5 ns resolution<br />
EASY TO SETUp<br />
Balancing<br />
User interface which guides through all steps<br />
Order tracking based balancing method<br />
Single or dual plane<br />
Multiple balancing for two directions saves time<br />
2D graph for plane view<br />
RpM channel with color indicator (RpM range)<br />
Alarm output if velocity exceeds predefined value<br />
Displays tacho probe time signal to set trigger<br />
vector polar plots of 1st order of all runs<br />
(initial, trail, ...)<br />
Weight splitting<br />
Acceleration, velocity, displacement in recorder<br />
Time domain measurement<br />
www.dewetron.com<br />
DE-D100301E • All trademarks are acknowledged to be the property of their owners. Specification subject to change without notice. © <strong>DEWE</strong>TRON Ges.m.b.H. 04/2010