08.11.2012 Views

DEWE-50-USB2-8_broch.. - Dewetron America

DEWE-50-USB2-8_broch.. - Dewetron America

DEWE-50-USB2-8_broch.. - Dewetron America

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Automotive<br />

Energy & power Analysis<br />

Aerospace & Defense<br />

Transportation<br />

General Test & Measurement<br />

<strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

Modular USB data acquisition system for isolated signal conditioners<br />

When connected to the high speed USB 2.0 interface of<br />

any computer the <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8 becomes a powerful<br />

measurement instrument for analog, digital, counter<br />

and CAn-bus data capture. Simply connect a webcam<br />

to your computer and add video information to your<br />

recorded data.<br />

Eight simultaneous analog inputs sample data at up<br />

to 204.8 kS/s and in combination with DAQp-series<br />

isolated signal conditioners almost any sensor can be<br />

connected.<br />

popular measurands are:<br />

voltage Strain<br />

Current Acceleration<br />

Force Torque<br />

pressure Sound<br />

position RpM<br />

Frequency velocity<br />

Resistance And more<br />

The included <strong>DEWE</strong>Soft application software adds<br />

powerful measurement and analysis capability, turning<br />

the <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8 into a dedicated recorder, scope,<br />

data logger or FFT analyzer.<br />

The isolated signal conditioners make this unit almost<br />

indestructible and a safe investment for many years.<br />

Key Features<br />

Connects to any computer via USB interface<br />

8 slots for isolated DAQp-series signal<br />

conditioners<br />

24 bit resolution, 204.8 kS/s per channel<br />

Simultaneous sampling, separate ADC per channel<br />

2 counters or 6 digital inputs<br />

2 high speed CAn interfaces<br />

EpAD2 expansion for slow signals<br />

<strong>DEWE</strong>Soft instrument software included<br />

The <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8 is the perfect fit for<br />

Mobile applications<br />

e.g. mobile shock and vibration tests<br />

Field service<br />

e.g. bringing into service tasks<br />

Maintenance<br />

e.g. order tracking<br />

in-vehicle tests<br />

e.g. trouble shooting, OBDii data recording<br />

industrial applications<br />

e.g. balancing<br />

www.dewetron.com<br />

AUTOMOTivE<br />

pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

1


pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

2<br />

Connectivity<br />

USB and SYnC interfaces<br />

The USB connection to a host computer is secured with<br />

a unique mini-USB connector which actually screws into<br />

the backside of the <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8, locking it in place,<br />

and guarding against accidental disconnection.<br />

For channel expansion up to 16 analog inputs a second<br />

<strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8 can directly be attached to the unit,<br />

USB and SYnC interfaces are prepared.<br />

EpAD<br />

Analog input<br />

There are eight slots for DAQp series isolated signal<br />

conditioners. The internal A/D system offers eight analog<br />

inputs, each has its own sigma-delta A/D converter and is<br />

sampled at up to 204.8 kS/s at 24 bit resolution. Anti-aliasing<br />

filters are included for each channel.<br />

<strong>DEWE</strong>TROn offers a wide range of DAQp modules, see pages<br />

6 and 7 for an overview.<br />

To enable signal conditioning for additional slow signals an EpAD interface is prepared. <strong>DEWE</strong>TROn EpAD2 series<br />

modules to acquire quasi-static thermocouple, RTD, voltage or current signals can be connected to this interface by<br />

a single cable. The sampling rate of an EpAD2 input channel is approx. 10 Hz / amount of modules.<br />

CAn<br />

There are two high speed CAn interfaces which are able to acquire data from vehicle CAn – or vehicle OBDii<br />

interface – as well as from any sensor outputting CAn data.<br />

Additionally <strong>DEWE</strong>TROn CpAD2 modules can be connected to a CAn interface. These modules have the same<br />

features as EpAD2 but the sampling rate does not depend on the amount of attached modules, so it can be 10 Hz<br />

in any case.<br />

Option <strong>50</strong>-8-OUT-5<br />

Optional eight BnC sockets can be installed to provide access to the conditioned ±5 v signal of each DAQp<br />

module.<br />

www.dewetron.com


Counter input features<br />

<strong>DEWE</strong>TROn has advanced the state-of-the-art in<br />

counter/encoder inputs in our data acquisition<br />

systems.<br />

The key advancement is that our counters<br />

are pHASE SYnCHROniZED. Referring to the<br />

diagram, you can see that a standard counter<br />

is always a sample behind. With software<br />

interpolation you can get closer, but only with<br />

<strong>DEWE</strong>TROn’s advanced time shifting technology<br />

are both the phase and amplitude fully<br />

corrected!<br />

RPM-Measurement<br />

Length-measurement<br />

Event Counting<br />

Waveform Timing<br />

Encoder<br />

Tacho<br />

Gearthooth, CDM<br />

ADC-clock<br />

Counter input<br />

ideal counting<br />

ORION-counter<br />

Software interpolation<br />

Standard counter<br />

Gearthooth, TRG, CDM and TRG<br />

Gearthooth with missing teeth<br />

Gearthooth with double teeth<br />

Linear encoder<br />

Linear pulse sensor<br />

Basic counting<br />

Gated counting<br />

Up/down counting<br />

period frequency<br />

Two pulse edge separation<br />

period, pulse width,<br />

frequency, duty cycle<br />

PORTaBLE INSTRUMENTS • <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

3


pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

4<br />

<strong>DEWE</strong>Soft<br />

Our award-winning data acquisition package is second to none when it comes to both pure recording power and<br />

ease of use. normally it is a difficult balancing act to provide lots of capability and performance, without making the<br />

user interface cumbersome and hard to learn. But with careful and innovative design, we have done exactly that!<br />

<strong>DEWE</strong>Soft is the solution to acquire signals synchronous from different sources, display and store them together<br />

and perform quick analyses.<br />

File browser in analyze mode<br />

Typical <strong>DEWE</strong>Soft report<br />

Typical <strong>DEWE</strong>Soft online display<br />

Key Features<br />

perfect sync of analog, digital, counter, CAn, GpS,<br />

video, ARinC, 1553 data … and even more<br />

Fast and easy setup of all kinds of input channels<br />

Failsafe and simple sensor setup by TEDS or<br />

sensor database<br />

powerful online data processing, MATH functions,<br />

filters, statistics, reference curves<br />

Attractive online display of all kind of data,<br />

creation of displays is a matter of seconds<br />

various storing strategies, stream data to hard<br />

disk (up to 100 MB/s), triggered storing or<br />

database storing<br />

Analog, digital or CAn data output, powerful<br />

function generator, alarms, CAn messages<br />

Build test procedures in a form of workflow<br />

diagram by means of our sequencer<br />

Fast data analysis, reload GB files in seconds<br />

post processing, a data file can be postprocessed<br />

on any computer<br />

Ready to us applications, power calculations,<br />

Combustion analysis, Torsional vibration, Order<br />

tracking, Sound analysis, Frequency response<br />

function, Human vibrations, Balancing ... and even<br />

more<br />

www.dewetron.com


SPECIFICaTIONS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

aNaLOG INPUT<br />

number of channels 8 (simultaneously sampled)<br />

Measured values According installed DAQp modules<br />

INTERNaL a/D SySTEM<br />

Resolution 24 bit<br />

Type of ADC Sigma-Delta<br />

Sampling rate 204.8 kS/s<br />

-3 dB bandwidth 76 kHz @ 204.8 kS/s<br />

(consider possible limit of DAQp module)<br />

Accuracy ±0.1 % of range, ±0.5 mv<br />

DyNaMIC CHaRaCTERISTICS<br />

Signal to noise @ fs


pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

6<br />

Selection guide<br />

DAQ series modules<br />

Single channel<br />

High bandwidth - for dynamic signals<br />

isolation (most models)<br />

Analog signal output (±5 v)<br />

Single channel modularity<br />

Module Input type Ranges TEDS<br />

Universal measurement<br />

Bandwidth (BW),<br />

Filters (LP = lowpass,<br />

HP = highpass)<br />

Isolation (ISO),<br />

Overvoltage<br />

protection (OP)<br />

DAQP-STG Strain gauge, bridge sensors ±0.1 to ±1000 mV/V (@ 5 VDCexc) ■ BW: 300 kHz ISO: 3<strong>50</strong> VDC<br />

Piezoresistive bridge ±0.5 to 10000 mV/mA (@ 1 mAexc) LP: 10 Hz to 300 kHz OP: ±<strong>50</strong> VDC<br />

Voltage<br />

Resistance<br />

±<strong>50</strong>0 µV to ±10 V<br />

25 mΩ to 100 kΩ<br />

Pt100, Pt200, Pt<strong>50</strong>0, Pt1000,<br />

Pt2000<br />

-200° C to 8<strong>50</strong>° C<br />

IEPE ® V<br />

via MSI-BR-ACC<br />

±2.5 to ±10000 mV<br />

MSI MSI MSI<br />

Thermocouple via MSI-BR-TH-x full range of TC type<br />

Charge via MSI-BR-CH-<strong>50</strong> up to <strong>50</strong>000 pC<br />

Voltage via MSI-BR-V-200 up to ±200 V<br />

High voltage measurement<br />

DAQP-HV High voltage ±20 to ±1400 V - BW: 300 kHz ISO: 1.8 kVRMS<br />

LP: 10 Hz to 300 kHz<br />

V<br />

DAQP-HV-S3 High voltage ±20 to ±1400 V - BW: 700 kHz ISO: 1.8 kVRMS<br />

LP: 10 Hz to 700 kHz<br />

V<br />

DAQP-DMM High voltage ±10 to ±1000 V - BW: 20/30 kHz ISO: 1.5 kVRMS<br />

LP: 10 Hz to 30 kHz<br />

V<br />

Voltage & current measurement<br />

DAQP-LV Voltage ±10 mV to ±<strong>50</strong> V ■ BW: 300 kHz ISO: up to 1 kVRMS<br />

Current with external shunt 20 mA / 5 A LP: 10 Hz to 300 kHz OP: 3<strong>50</strong> VDC<br />

IEPE ® via MSI-V-ACC<br />

±10 mV to 10 V<br />

V<br />

MSI MSI<br />

Pt100, Pt200, Pt<strong>50</strong>0, Pt1000, -200° C to 1000° C and<br />

Pt2000 and resistance via 0 to 6.5 kOhm<br />

MSI-V-RTD<br />

Charge via MSI-V-CH-<strong>50</strong> up to <strong>50</strong>000 pC<br />

DAQP-V Voltage 10 mV to <strong>50</strong> V - BW: <strong>50</strong> kHz ISO: up to 1 kVRMS<br />

Current with external shunt 20 mA / 5 A LP: 10 Hz to <strong>50</strong> kHz OP: ±<strong>50</strong>0 VDC<br />

V<br />

DAQN-AIN Voltage ±10 V (1:1 input) - - OP: < ±<strong>50</strong>0 V<br />

(jumper<br />

selectable)<br />

V<br />

Current measurement<br />

MSI<br />

DAQP-LA-SC Current 0.1 A to 30 A peak - BW: 300 kHz ISO: 1.4 kVRMS<br />

Note: 5 ARMS continuous max. 5 ARMS contin. current LP: 10 Hz to 300 kHz<br />

DAQP-LA-B Current 2 mA to 600 mA - BW: 300 kHz ISO: 1.4 kVRMS<br />

Note: typ. 20 mA application LP: 10 Hz to 300 kHz<br />

www.dewetron.com<br />

■ = standard


Module Input type Ranges TEDS<br />

Bridge / strain gauge and carrier frequency amplifier<br />

OUT<br />

Bandwidth (BW),<br />

Filters (LP = lowpass,<br />

HP = highpass)<br />

Isolation (ISO),<br />

Overvoltage<br />

protection (OP)<br />

DAQP-CFB AC bridge, strain gauge Bridge: 0.1 to 1000 mV/V - BW: DC to 2.3 kHz OP: ±10 VDC<br />

Note : 5 kHz sine wave excitation LP: 10 Hz to 1 kHz<br />

Inductive sensors, LVDT Inductive: 5 to 1000 mV/V<br />

DAQP-BRIDGE-A Strain gauge, bridge sensors ±1 to ±<strong>50</strong> mV/V (@ 5 VDC) - BW: 20 kHz ISO: 3<strong>50</strong> VDC<br />

LP: 10 Hz to 20 kHz OP: ±10 VDC<br />

Potentiometric sensors 200 Ω to 10 kΩ<br />

DAQP-BRIDGE-B Strain gauge, bridge sensors ±0.1 to ±100 mV/V (@ 5 VDC) ■ 1) BW: 200 kHz OP: ±10 VDC<br />

LP: 10 Hz to 200 kHz<br />

Charge / IEPE ® measurement<br />

Potentiometric sensors 200 Ω to 10 kΩ<br />

DAQP-ACC-A IEPE ® sensors ±<strong>50</strong> mV to ±5 V - BW: 0.5 Hz to 300 kHz -<br />

LP: 1 to 300 kHz<br />

HP: 0.5 Hz and 5 Hz<br />

DAQP-CHARGE-A Charge sensors Charge: 5 to <strong>50</strong>000 pC - BW: 0.1 Hz to <strong>50</strong> kHz -<br />

IEPE ® sensors IEPE ® : ±5 mV to 5 V LP: 100 Hz to <strong>50</strong> kHz<br />

Note: selectable integration and<br />

double integration<br />

HP: 0.1 Hz to 10 Hz<br />

DAQP-CHARGE-B Charge sensors ±100 to ±1 000 000 pC - BW: DC to 100 kHz ISO: 3<strong>50</strong> VDC<br />

Temperature measurement<br />

LP: 10 Hz to 100 kHz<br />

Note: selectable time constant HP: DC, 0.001 Hz to 0.5 Hz<br />

for static sensors<br />

DAQN-THERM-x Thermocouple K and J type (others on request) - BW: 4 Hz ISO: 1 kVRMS<br />

DAQN-THERM-1 K: -30 to 170 °C<br />

Note: internal CJC DAQN-THERM-2 K: -30 to 370 °C<br />

DAQN-THERM-3 K: 0 to 1000 °C<br />

DAQN-THERM-4 K: -100 to 13<strong>50</strong> °C<br />

DAQN-THERM-5 J: -100 to 760 °C<br />

DAQN-RTD-x Thermoresistors Pt100 - BW: 10 Hz -<br />

DAQN-RTD-1: -30 to 170 °C<br />

DAQN-RTD-2: -100 to 200 °C<br />

DAQN-RTD-3: -<strong>50</strong> to 600 °C<br />

Frequency measurement<br />

DAQP-FREQ-A Frequency 100 Hz to 200 kHz - BW: according to range<br />

Output response:<br />

1.5 ms<br />

30 ms<br />

<strong>50</strong>0 ms<br />

ISO: 3<strong>50</strong> VDC<br />

Voltage output module<br />

DAQN-V-OUT Voltage output 1:1 output module with isolation - BW: 400 Hz ISO: 240 VDC<br />

Input voltage: ±10 V<br />

Output voltage: ±10 V<br />

1) TEDS support for DAQP-BRIDGE-B revision 2 only ■ = standard<br />

ADAp-D9M-BnCF:<br />

DSUB to BnC adapter<br />

for DAQp-v series and<br />

DAQp-FREQ modules<br />

BnC to Microdot adapter<br />

(included as a standard with<br />

DAQp-CHARGE-A modules)<br />

COnn-DSUB-9:<br />

Screw terminal adapter<br />

for all modules with 9-pin<br />

DSUB connector<br />

BnC to banana and<br />

banana to BnC adaptors<br />

isolated high-voltage amplifier:<br />

DAQp-Hv<br />

PORTaBLE INSTRUMENTS • <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

7


pORTABLE inSTRUMEnTS <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8<br />

8<br />

applications<br />

Recorder<br />

Synchronous recording of different signals<br />

voltage Acceleration<br />

pressure Force<br />

Temperature Sound<br />

position RpM<br />

Torque Frequency<br />

velocity And more<br />

Torsional and Rotational vibration<br />

Time domain measurement<br />

Angle based view<br />

Additional to all other functions (analog, CAn, GpS, video, ...)<br />

Configurable display<br />

Direct sensor connection<br />

80 MHz time base<br />

High resolution ±0.03rpm ±2 mdeg@12000 rpm<br />

The shown applications are only a few examples, many more can be covered using<br />

the <strong>DEWE</strong>-<strong>50</strong>-<strong>USB2</strong>-8 instrument.<br />

<strong>DEWE</strong>TRON Ges.m.b.H. • Parkring 4 • A-8074 Graz-Grambach<br />

Tel (0043) 316 3070 0 • Fax (0043) 316 3070 90 • sales@dewetron.com<br />

Order Tracking<br />

Dedicated re-sampling method for sharp order separation<br />

Measurement in time domain to keep all benefits<br />

2D, 3D waterfall in order or frequency domain<br />

Amplitude, phase extraction<br />

Recalculation in post processing<br />

phase synchronous RpM input with 12.5 ns resolution<br />

EASY TO SETUp<br />

Balancing<br />

User interface which guides through all steps<br />

Order tracking based balancing method<br />

Single or dual plane<br />

Multiple balancing for two directions saves time<br />

2D graph for plane view<br />

RpM channel with color indicator (RpM range)<br />

Alarm output if velocity exceeds predefined value<br />

Displays tacho probe time signal to set trigger<br />

vector polar plots of 1st order of all runs<br />

(initial, trail, ...)<br />

Weight splitting<br />

Acceleration, velocity, displacement in recorder<br />

Time domain measurement<br />

www.dewetron.com<br />

DE-D100301E • All trademarks are acknowledged to be the property of their owners. Specification subject to change without notice. © <strong>DEWE</strong>TRON Ges.m.b.H. 04/2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!