28.12.2014 Views

UH Series - Mason Technology

UH Series - Mason Technology

UH Series - Mason Technology

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

C221-E3490C<br />

<strong>UH</strong> <strong>Series</strong><br />

Shimadzu<br />

Universal Testing Machines


Acquisition of ISO9001 certification<br />

High-precision force measurement<br />

Various measurement modes<br />

Automatic measurement


<strong>UH</strong> <strong>Series</strong><br />

Shimadzu Universal Testing Machines<br />

As global environmental problems become more and more<br />

serious, materials are required to provide light weight,<br />

high strength and reliability. The <strong>UH</strong> <strong>Series</strong> Shimadzu<br />

Universal Testing Machines are new universal testing<br />

machines that provide various functions enabling more<br />

accurate and simplified measurement of the strength<br />

required for various materials.<br />

The <strong>UH</strong> series enable high-precision<br />

force measurement conforming to<br />

the global standards.<br />

The <strong>UH</strong> series provide various<br />

automatic control programs as<br />

standard functions.<br />

After a specimen is mounted, all<br />

operations can be automatically<br />

performed.<br />

The <strong>UH</strong> series are high-quality<br />

products manufactured in the<br />

factory that acquired the ISO9001<br />

certification.<br />

Contents<br />

P 04 - Features of <strong>UH</strong>-I<br />

P 10 - Operation Unit<br />

P 16 - Specifications Measurement&Control Unit<br />

P 06 - Features of <strong>UH</strong>-FI<br />

P 12 - Software<br />

P 18 - Layout/Installation<br />

P 08 - Control Functions/Configuration<br />

P 14 - Specifications Loading Unit


The <strong>UH</strong>-I series support material strength<br />

tests by providing reliable data.<br />

4


<strong>UH</strong>-I<br />

Shimadzu<br />

Computer-controlled hydraulic servo system<br />

The functions of the <strong>UH</strong>-I series are greatly advanced,<br />

as compared with conventional testing machines.<br />

The large-sized LCD touch panel<br />

greatly simplifies operations and<br />

enhances visibility.<br />

The <strong>UH</strong>-I series provide the graphical interface<br />

that enables various functions<br />

to be operated on the one-touch panel.<br />

During a test, a S-S curve is plotted in real time.<br />

The <strong>UH</strong>-I series newly provide<br />

various automatic control programs<br />

as standard functions.<br />

The metal tensile test control program is provided as a<br />

standard function (conforming to JIS Z2241)<br />

The single test control, cycle test control, high-temperature<br />

tensile test control, stroke speed 3-step switching control<br />

programs are provided as standard functions.<br />

Through the fully-closed loop automatic load control,<br />

the <strong>UH</strong>-I series enable stable and accurate tests.<br />

Force auto-zero and auto-calibration<br />

functions<br />

The <strong>UH</strong>-I series greatly simplify operations by<br />

omitting troublesome adjuster knob operations.<br />

The non-revolving screw rod<br />

improves safety.<br />

A specimen can be safely mounted and<br />

dismounted.<br />

With various application testing<br />

equipment, the <strong>UH</strong>-I series are<br />

applicable to various tests.<br />

Various test jigs, displacement measuring<br />

equipment, atmosphere testing equipment,<br />

test control programs, etc.(See the catalog for<br />

optional accessories.)<br />

With connection to the optional data<br />

processing program,<br />

the <strong>UH</strong>-I series enable high-speed<br />

test data sampling.<br />

The <strong>UH</strong>-I series perform data sampling at a high<br />

speed (5 ms max.) to obtain a true value.<br />

The <strong>UH</strong>-I series can be connected to a personal computer<br />

through the personal computer's standard RS-232C serial<br />

interface. Also, they can be connected to a notebook<br />

computer, saving the required space. (The GP-IB or another<br />

special interface is not necessary.)<br />

5


The <strong>UH</strong>-FI series provide easy-to-operate<br />

front-opening hydraulic grips.<br />

6


<strong>UH</strong>-FI<br />

Shimadzu<br />

Computer-controlled hydraulic servo system<br />

With Highly-efficient, front-opening hydraulic grips<br />

The <strong>UH</strong>-I series advanced functions are further upgraded.<br />

Easy-to-operate front-opening hydraulic grips<br />

The front-opening hydraulic grips using the center hole hydraulic cylinder improves the efficiency in removing a<br />

specimen and scale, and ensures safe operation.<br />

Also, these grips enable even long specimens to be easily mounted.<br />

These grips can be enhanced to the highly-functional, labor-saving model that has the automatic grip face<br />

changing functions.<br />

The compression plate can be easily<br />

mounted anddismounted<br />

A wrench or other tool is not necessary.<br />

A specimen grip position index is<br />

provided<br />

With the specimen grip position index, the grips<br />

can easily and accurately grip a specimen.<br />

The grip face holder is equipped<br />

with a safety stopper<br />

The safety stopper prevents the right and left grip<br />

faces from coming into contact<br />

due to erroneous operation, so that the grip faces<br />

will not be damaged.<br />

The <strong>UH</strong>-FI series can be enhanced<br />

to a fully-automated tensile test<br />

system<br />

All operations including specimen dimension<br />

measurement, specimen feeding<br />

operation, test data processing and chart display<br />

can be automated.<br />

7


High precision control using closed<br />

[ Computer-controlled hydraulic servo system ]<br />

Measurement Control Unit<br />

Lower crosshead<br />

elevating switch<br />

Loading pump<br />

ON/OFF switch<br />

Operation unit<br />

Emergency stop switch<br />

Load control knob<br />

Control Functions<br />

(1) Constant-speed control<br />

Stroke/Force/Strain<br />

(2) Constant-speed control -><br />

Hold control<br />

Stroke/Force/Strain<br />

(3) Cycle test control<br />

NOTE 1)<br />

Stroke/force/strain cycle tests can be performed.<br />

Control value<br />

Control value<br />

Control<br />

value<br />

Max.<br />

point<br />

1st<br />

Hold control (0 to 10 hours)<br />

2nd<br />

Min.<br />

point<br />

Hold control (0 to 10 hours)<br />

Time<br />

Time<br />

Time<br />

(4) Stress test control (Metal tensile test control) (5) High-temperature tensile test control (6) Stroke speed 3-step switching control<br />

Metal tensile test control is performed according to each<br />

standard (ISO 6892, EN 10002, JIS Z2241, ASTM E8M, etc.).<br />

This control mode automatically performs tensile tests<br />

according to JIS G0567.<br />

Stroke control for metal tensile test conforming to JIS Z2441<br />

Stress<br />

Switching point 1<br />

Force<br />

Switching point<br />

Break<br />

Stroke<br />

Break<br />

Switching point 2<br />

Switching<br />

point 2<br />

Displacement<br />

Constant-speed<br />

stress control<br />

Constant-speed<br />

stress control<br />

Displacement<br />

3% of<br />

full-scale<br />

force<br />

Initial stroke control<br />

Constant-speed<br />

strain control<br />

Constant-speed<br />

stroke control<br />

Time<br />

Switching<br />

point 1<br />

Time<br />

Constant-speed stroke control Constant-speed stroke control Constant-speed stroke control<br />

NOTE 1) A optional oil cooling unit may be required depending on the installation conditions<br />

and operation conditions (for example, to perform hold control continuously for at least 30<br />

minutes) (See p. 17.)<br />

NOTE 2) Various control modes are optionally available. (See p. 17.)<br />

NOTE 3)Various cycle tests can be performed in the "Constant-speed control -> Hold<br />

control" modes by specifying the parameters repeatedly.<br />

8


loop system<br />

<strong>UH</strong> <strong>Series</strong> Configuration<br />

Universal<br />

testing machine<br />

Standard<br />

test jigs<br />

Standard<br />

control functions<br />

Loading unit<br />

Measurement<br />

control unit<br />

Hydraulic system<br />

Grip faces<br />

for tensile test<br />

Compression<br />

plate for<br />

compression test<br />

Single control<br />

Cycle control<br />

Stress test control<br />

(Metal tensile<br />

test control)<br />

High-temperature<br />

tensile test control<br />

Stroke speed 3-step<br />

switching control<br />

Application testing equipment (Option)<br />

Various jigs/devices<br />

Data processing/display<br />

/recording devices<br />

Measurement<br />

control functions<br />

Tensile test jig<br />

Compression test jig<br />

Bending test jig<br />

Atmosphere testing device<br />

Analog force indicator<br />

Analog recorder<br />

X-TP type or X-YTP type<br />

Simple data<br />

processing unit<br />

DATA LETTY 531<br />

Various control<br />

functions<br />

• Concrete test control<br />

• Pattern control<br />

• Display of force<br />

for specified<br />

elongation, etc.<br />

Displacement measuring device<br />

Windows XP/2000/Me/NT4.0/98/95<br />

Software TRAPEZIUM2<br />

9


The abundant functions improve<br />

Measurement Control Unit (Operation Unit)<br />

Large character display<br />

The large-sized force/stroke data display<br />

can be easily read. The display can be<br />

switched to the stress value display mode<br />

or displacement value display mode with a<br />

touch of a button.<br />

S-S curve display<br />

During a test, a S-S curve is displayed in<br />

real time.<br />

Testing machine operating status<br />

/test condition display<br />

Since the testing machine's operating<br />

status and test conditions can be checked<br />

at a glance, an erroneous setting or<br />

erroneous operation can be prevented.<br />

Operation keys<br />

For frequently-used control switches,<br />

highly-durable mold type switches are<br />

used.<br />

Test Condition Menu Screen<br />

The testing machine's functions can be visibly operated with<br />

the icon buttons. It can prevent erroneous operation, and<br />

improve the test efficiency.<br />

File Operation Screen<br />

The test condition changeover operation can be simplified<br />

by storing test conditions in a file of each test type.<br />

10


the test efficiency.<br />

Force Auto-calibration Function<br />

The electrical force calibration can be performed with a<br />

touch of a button, without the necessity of troublesome<br />

adjuster knob operations.<br />

Auto/Full-Auto Force Range Switching Function<br />

When a recorder is connected, the force range is<br />

automatically changed immediately before the force output<br />

signal exceeds the full-scale value.<br />

Auto-return Function<br />

This function automatically returns the ram of the testing<br />

machine to the origin with a touch of a button. When the<br />

auto-return function is used together with the break<br />

detecting function, the testing machine automatically<br />

returns to the origin after detection of a specimen break.<br />

PEAK/BREAK Value Display Function<br />

The force, stress and strokes values at the maximum<br />

force point and break point are displayed during a test.<br />

When a displacement meter is connected, the<br />

displacement value at each point can be also displayed.<br />

Break Detecting Function<br />

This function detects a specimen break to automatically<br />

stop the testing machine and return it to the origin.<br />

Cycle Count Function<br />

During a cycle test, the number of repeated load applied<br />

to the specimen is displayed. Also, this function can stop<br />

the test, or break the specimen in the preset cycle<br />

number.<br />

Bilingual Function<br />

Japanese or English can be selected on the LCD touch<br />

panel screen. The display language can be switched with a<br />

touch of a button on the screen.<br />

11


The high-speed data sampling obtains<br />

Test Control & Data Processing<br />

For Windows ® 95/98/NT4.0/2000/Me/XP <strong>UH</strong> <strong>Series</strong> Software<br />

Part No. 345-47313<br />

5 ms High-speed Sampling<br />

To monitor the change in the material completely, the <strong>UH</strong><br />

series perform data sampling at an interval of 5 ms max. (for<br />

100 seconds), enabling high-precision force measurement in<br />

the elastic region and break region. For normal sampling, the<br />

sampling interval can be set to 50 ms (max.), 100 ms or 150<br />

ms.<br />

High-speed sampling<br />

100 seconds (max.)<br />

Normal sampling<br />

The newest User Interface<br />

The TRAPEZIUM provides the easy-to-operate user interface, which is based on the global design incorporating the<br />

opinions of worldwide users and software experts.<br />

Wizard<br />

Graph<br />

Easy and flexible setting using wizard<br />

A curve can be traced with the picking function<br />

Menu Customize<br />

On-line Help<br />

Screen customize function<br />

Useful on-line help<br />

12


a true value.<br />

Software (Option)<br />

Test Data Protecting Security Function<br />

The TRAPEZIUM provides a security function for preventing test data from<br />

being erroneously deleted or overwritten. With the ID and password<br />

predetermined for the manager or operator, the system enables only the menu<br />

and buttons necessary for each person to be operated. Also, the TRAPEZIUM<br />

provides the log file function that automatically records operation contents.<br />

Security<br />

functions<br />

Overwrite prevention<br />

Password setting<br />

Record of operation contents<br />

Test data protection<br />

Link to General-purpose Software<br />

The TRAPEZIUM can be quickly linked to spreadsheet and word processing<br />

software. Test conditions, test results and sampling data can be exported in<br />

the "* .csv" format, and graphs can be exported in the "* .wmf" format.<br />

Link to spreadsheet and<br />

word processing software<br />

Test result export<br />

TRAPEZIUM2 is all-around software<br />

Tensile, compression, 3-point bending, 4-point bending, Concrete, Shear, Friction, Tensile cycle,<br />

Compression cycle, 3-point bending cycle, 4-point bending cycle, Creep and Relaxation Tests<br />

List of data processing items<br />

The circle indicates an available data processing item.<br />

Tensile Compression 3-point bending 4-point bending Cycle Concrete Control<br />

Elastic modulus (4 types)<br />

Upper yield point<br />

Lower yield point<br />

Yield strength point (2 points)<br />

Intermediate force (5 points)<br />

Intermediate displacement (5 points)<br />

Maximum force point<br />

Minimum force point<br />

Break point<br />

Joint elongation/reduction<br />

Energy<br />

Reciprocation energy<br />

Hysteresis<br />

n value, r value. Poisson's ratio<br />

Arbitrary calculation formula (10 formulae)<br />

(2 types)<br />

(Poisson's ratio)<br />

(1 type)<br />

(Arbitrary number of points)<br />

(Arbitrary number of points)<br />

English/Spanish/Chinese (Simplified/Traditional)/Korean/Portuguese/Japanese available (Other languages available on request)<br />

13


Loading Unit Standard Specifications<br />

Standard <strong>Series</strong><br />

SI unit<br />

Type<br />

Part No.<br />

<strong>UH</strong>-200kNI<br />

346-43051<br />

<strong>UH</strong>-300kNI<br />

346-43052<br />

<strong>UH</strong>-500kNI<br />

346-43053<br />

<strong>UH</strong>-F500kNI<br />

346-43070<br />

<strong>UH</strong>-600kNI<br />

346-43249<br />

Capacity<br />

Max. capacity<br />

200kN<br />

(20tf,45000Lbf)<br />

300kN<br />

(30tf,67500Lbf)<br />

500kN<br />

(50tf,112500Lbf)<br />

600kN<br />

(60tf,135000Lbf)<br />

Force range (6 steps)<br />

200/100/40/20/10/4kN 300/150/60/30/15/6kN<br />

500/250/100/50/25/10kN<br />

600/300/120/60/30/12kN<br />

Specifications<br />

Max. grip span (mm)<br />

800<br />

800<br />

900<br />

900<br />

1.Tensile test<br />

Grips for rod specimens (mm)<br />

(Option)<br />

ø8~40<br />

With liner<br />

ø8~40<br />

With liner<br />

ø12~50<br />

With liner<br />

ø12~30<br />

ø30~50<br />

ø12~50<br />

With liner<br />

Grips for flat plate specimens (Option)<br />

(mm)<br />

Max. compression plate span (mm)<br />

2.Compression test<br />

Compression plate size (mm)<br />

Max. support span (mm)<br />

3.Transverse<br />

/bending test<br />

(Option)<br />

4.Loading speed<br />

(60 Hz)<br />

5.Ram stroke<br />

6.Crossheadelevation<br />

speed(60 Hz)<br />

7.Post span<br />

Support diameter x Width (mm)<br />

Punch tip radius (mm)<br />

Punch width (mm)<br />

Motor capacity (3-phase)<br />

(mm)<br />

(Approx.)(mm/mim)<br />

Motor capacity (3-phase)<br />

(mm)<br />

0~35<br />

(50 in width)<br />

720<br />

ø100<br />

500<br />

30 x 130<br />

15<br />

130<br />

100 max.<br />

1.5kW<br />

200<br />

380<br />

400W<br />

500<br />

0~35<br />

(50 in width)<br />

720<br />

ø100<br />

500<br />

30 x 130<br />

15<br />

130<br />

100 max.<br />

1.5kW<br />

200<br />

380<br />

400W<br />

500<br />

0~45<br />

(60 in width)<br />

800<br />

ø120<br />

600<br />

50 x 160<br />

25<br />

160<br />

80 max.<br />

1.5kW<br />

250<br />

450<br />

750W<br />

650<br />

0~30,30~50<br />

(60 in width)<br />

800<br />

ø120<br />

600<br />

50 x 160<br />

25<br />

160<br />

80 max.<br />

1.5kW<br />

250<br />

250<br />

Hydraulic motor<br />

650<br />

0~45<br />

(60 in width)<br />

800<br />

ø120<br />

600<br />

50 x 160<br />

25<br />

160<br />

180 max.<br />

5.5kW<br />

250<br />

450<br />

750W<br />

650<br />

8.Effective table dimensions (Width x Depth) (mm)<br />

9.Power supply capacity<br />

(3-phase, 200/220 V, 50/60 Hz)<br />

(Approx.)<br />

500 x 500<br />

3.5kVA<br />

500 x 500<br />

3.5kVA<br />

650 x 650<br />

4kVA<br />

650 x 650<br />

6.6kVA<br />

650 x 650<br />

9kVA<br />

10. Recommended breaker capacity<br />

(3-phase, 200/220 V, 50/60 Hz)<br />

20A<br />

20A<br />

20A<br />

30A<br />

50A<br />

11.Testing<br />

machine size<br />

(Width x Depth<br />

x Height)<br />

Testing machine (mm)<br />

Measurement control unit (mm)<br />

780 x 500 x 2000<br />

700 x 800 x 1070<br />

780 x 500 x 2000<br />

700 x 800 x 1070<br />

960 x 650 x 2400<br />

700 x 800 x 1070<br />

1060 x 700 x 2900<br />

700 x 800 x 1070<br />

960 x 650 x 2400<br />

700 x 1000 x 1070<br />

12.Testing<br />

machine weight<br />

(Width x Depth<br />

x Height)<br />

Testing machine (kg)<br />

Measurement control unit (kg)<br />

900<br />

900<br />

125<br />

1700<br />

2600<br />

1700<br />

NOTE<br />

1) The <strong>UH</strong> series provide the above loading speeds when no specimen is mounted and the oil temperature is 20°C or a higher temperature.<br />

2) The hydraulic loading system is incorporated in the measurement control unit.<br />

(For the testing machines with 3000 kN or higher capacity, the hydraulic loading system is separately provided.)<br />

3) The standard testing machines provide force accuracy of within ±1.0% of the indicated value.<br />

With the optional high-precision type, the force accuracy is within ±0.5%.<br />

4) The transverse/bending test jigs are optionally available.<br />

5) For a different paint color, contact Shimadzu or a local distributor.<br />

6) In elasticity testing, one set of grip for rod specimens is included as standard equipment. Other types of grips are optional.<br />

Note: These standard grips are designed for use with specimens with a hardness of HRC40 or less. When using specimens harder than this,<br />

contact us and we will prepare high-hardness grips.<br />

14


Large-capacity <strong>Series</strong><br />

<strong>UH</strong>-1000kNI<br />

346-43055<br />

<strong>UH</strong>-F1000kNI<br />

346-43071<br />

<strong>UH</strong>-2000kNI<br />

346-43056<br />

<strong>UH</strong>-F2000kNI<br />

346-43072<br />

<strong>UH</strong>-3000kNI<br />

346-43057<br />

<strong>UH</strong>-F3000kNI<br />

346-43073<br />

<strong>UH</strong>-4000kNI<br />

346-43058<br />

<strong>UH</strong>-F4000kNI<br />

346-43074<br />

1000kN<br />

2000kN<br />

3000kN<br />

4000kN<br />

(100tf,225000Lbf)<br />

(200tf,450000Lbf)<br />

(300tf,675000Lbf)<br />

(400tf,9000000Lbf)<br />

1000/500/200/100/50/20kN<br />

2000/1000/400/200/100/40kN<br />

3000/1500/600/300/150/60kN<br />

4000/2000/800/400/200/80kN<br />

1000<br />

1100<br />

1200<br />

1400<br />

ø12~70<br />

ø12~40<br />

ø20~90<br />

ø20~55<br />

ø20~110<br />

ø20~55<br />

ø30~120<br />

ø20~60<br />

With liner<br />

With liner<br />

With liner<br />

With liner<br />

ø40~70<br />

ø55~90<br />

ø55~85<br />

ø60~90,ø90~120<br />

0~65<br />

0~35,35~70<br />

0~85<br />

0~45,45~90<br />

0~105<br />

0~55,55~110<br />

0~115<br />

0~60,60~120<br />

(70 in width)<br />

(70 in width)<br />

(90 in width)<br />

(90 in width)<br />

(110 in width)<br />

(110 in width)<br />

(120 in width)<br />

(120 in width)<br />

900<br />

900<br />

950<br />

950<br />

1000<br />

1000<br />

1150<br />

1150<br />

ø160<br />

ø160<br />

ø220<br />

ø220<br />

ø280<br />

ø280<br />

ø300<br />

ø300<br />

800<br />

800<br />

900<br />

900<br />

1000<br />

1000<br />

1000<br />

1000<br />

50 x 160<br />

50 x 160<br />

70 x 200<br />

70 x 200<br />

80 x 230<br />

80 x 230<br />

80 x 250<br />

80 x 250<br />

25<br />

25<br />

30, 40<br />

30, 40<br />

40, 50<br />

40, 50<br />

40, 50<br />

40, 50<br />

160<br />

160<br />

160<br />

160<br />

230<br />

230<br />

250<br />

250<br />

70 max.<br />

70 max.<br />

50 max.<br />

50 max.<br />

50 max.<br />

50 max.<br />

50 max.<br />

50 max.<br />

2.2kW<br />

2.2kW<br />

5.5kW<br />

5.5kW<br />

5.5kW<br />

5.5kW<br />

7.5kW<br />

7.5kW<br />

250<br />

250<br />

300<br />

300<br />

300<br />

300<br />

350<br />

350<br />

400<br />

200<br />

350<br />

350<br />

350<br />

350<br />

350<br />

350<br />

1.5kW<br />

Hydraulic motor<br />

1.5kW<br />

2.2kW<br />

2.2kW<br />

3.7kW<br />

3.7kW<br />

5.5kW<br />

750<br />

750<br />

850<br />

850<br />

1000<br />

1000<br />

1150<br />

1150<br />

750 x 750<br />

750 x 750<br />

850 x 850<br />

850 x 850<br />

1000 x 1000<br />

1000 x 1000<br />

1150 x 1150<br />

1150 x 1150<br />

6kVA<br />

8kVA<br />

10kVA<br />

13kVA<br />

11kVA<br />

15kVA<br />

16kVA<br />

18kVA<br />

30A<br />

50A<br />

50A<br />

75A<br />

60A<br />

75A<br />

100A<br />

100A<br />

1170 x 750 x 2800<br />

1320 x 800 x 3400<br />

1560 x 920 x 3400<br />

1560 x 920 x 4500<br />

1860 x 1100 x 3970<br />

1860 x 1100 x 5700<br />

2200 x 1400 x 4800<br />

2200 x 1400 x 5900<br />

700 x 800 x 1070<br />

700 x 800 x 1070<br />

700 x 1000 x 1070<br />

700 x 1000 x 1070<br />

700 x 800 x 1070<br />

700 x 800 x 1070<br />

700 x 800 x 1070<br />

700 x 800 x 1070<br />

3500<br />

6000<br />

125<br />

NOTE The large-capacity series are produced at customers' request. For details, contact Shimadzu or a local distributor.<br />

15


Measurement and Control Unit<br />

1. Loading method<br />

2. Force<br />

measurement<br />

Method<br />

Accuracy Standard type<br />

Computer-controlled electro-hydraulic servo system<br />

Cylinder internal pressure measurement with high-precision pressure cell<br />

Within ±1.0% of indicated value (when the force is 1/5 or more of the full scale for each force range)<br />

*1(Conforming to JIS B7721 Class 1, ISO 7500/1 Class 1, and ASTM E4)<br />

3. Force display<br />

Magnification<br />

Operation unit<br />

High-precisiontype<br />

(Option)<br />

Analog indicator (Option)<br />

Within ±0.5% of indicated value (when the forece is 1/5 or more of the full scale for each force range)<br />

*1 (Conforming to JIS B7721 Class 0.5, ISO 7500/1 Class 0, and ASTM E4)<br />

x1, x2, x5, x10, x20 and x50 (6 steps)<br />

Digital display Display resolution: 1/2000 (300 kN/600 kN/3000 kN: 1/3000)<br />

Display unit: N, kN, kgf, tf, lbf<br />

Analog display Scale plate diameter: 450 mm<br />

Min. scale: 1/1000 (300 kN/600 kN/3000 kN: 1/600)<br />

Digital display Display resolution: 1/2000 (300 kN/600 kN/3000 kN: 1/3000)<br />

4. Stroke measurement display<br />

Display unit: kN<br />

Measurement with optical encoder<br />

5. Automatic<br />

load control<br />

Method<br />

Test control functions<br />

Range<br />

Fully-closed loop automatic load control Display unit: mm, in<br />

Digital display (Display resolution: 0.1 mm)<br />

Single test control,Cycle test control (Triangular wave, Trapezoidal wave),Stress test control (Metal<br />

tensile test control), High-temperature tensile test control, Stroke speed 3-step switching control<br />

Ram stroke control Speed range: 0.5 mm/min(0.02 in /min) to Max. loading speed *2<br />

Control range: Ram return point to Max. ram stroke<br />

Force contro<br />

Speed range: 0.1 to 5.0 full-scale/min.<br />

Control range: 5 to 100% of full-scale force<br />

Strain control<br />

Speed range: 0.1 to 80% /min.<br />

Control range: 5 to 100% of full-scale elongation<br />

6. Input/output interface<br />

External analog input: 2 CH<br />

External analog output: 2 CH<br />

Recorder output: RS-232C interface<br />

Two displacement meter amplifiers can be incorporated. (Option)<br />

7. Standard functions<br />

Force auto-zero function, Force auto-calibration function,<br />

Break detecting function, Auto/Full-auto force range switching function, Auto-return function,<br />

Arbitrary stroke speed setting function, Cycle count function, PEAK/BREAK value display function,<br />

Stress value display function, Force value display function, Stroke value display function,<br />

Displacement meter displacement value display function, Test condition file function,<br />

Japanese/English display function, S-S curve display function, Manual load control function<br />

8. Safety devices<br />

Overload automatic stop function<br />

(When the force value exceeds 102% of the full-scale value, the loading pump automatically stops.)<br />

Control automatic stop function<br />

(When the control deviation exceeds ±10% of the full-scale value, the test automatically stops.)<br />

Emergency stop switch<br />

*1 Calibration is required after installation to provide conformance.<br />

*2 For the maximum loading speed, refer to the testing machine specifications.<br />

Conformity with CE mark regulation<br />

16


Standard Specifications<br />

Universal Testing Machines Extension <strong>Series</strong><br />

When the extension series of universal testing machines are used together with the application testing<br />

equipment, a wider range of tests can be performed.For details, refer to the catalogs for the application testing<br />

equipment and application testing system.<br />

Testing Machine Loading Unit with Extended Post/Screw Rod<br />

To mount application testing equipment such as the bending test jig, thermostatic chamber and high-temperature furnace to the loading unit, extended<br />

posts and screw rod may be required. Select the extension model depending on the occupied space of each testing equipment and the specimen size.<br />

Applicable testing machine Extension model S Extension model M Extension model L<br />

<strong>Series</strong><br />

name<br />

Capacity<br />

Standard grip<br />

span(mm)<br />

Extension<br />

length(mm)<br />

Allowable<br />

tensile force<br />

Part No.<br />

Extension<br />

length(mm)<br />

Allowable<br />

tensile force<br />

Part No.<br />

Extension<br />

length(mm)<br />

Allowable<br />

tensile force<br />

Part No.<br />

<strong>UH</strong>-I<br />

<strong>UH</strong>-FI<br />

NOTE<br />

200/300<br />

500<br />

600<br />

1000<br />

2000<br />

500<br />

1000<br />

2000<br />

800<br />

900<br />

900<br />

1000<br />

1100<br />

900<br />

1000<br />

1100<br />

*300<br />

*300<br />

*200<br />

*200<br />

*300<br />

*200<br />

*200<br />

Full force<br />

Full force<br />

Full force<br />

Full force<br />

320<br />

800<br />

1800<br />

343-01072-03<br />

343-01072-03<br />

343-01073-02<br />

343-01074-02<br />

343-02525-03<br />

343-02526-02<br />

343-02527-02<br />

*400<br />

500Top plate attached<br />

500Top plate attached<br />

500Top plate attached<br />

500Top plate attached<br />

500Top plate attached<br />

500Top plate attached<br />

500Top plate attached<br />

Full force<br />

400<br />

400<br />

Full force<br />

Full force<br />

250<br />

600<br />

1500<br />

343-01071-04 600Top plate attached<br />

343-01072-05 800Top plate attached<br />

343-01072-05 800Top plate attached<br />

343-01073-05 800Top plate attached<br />

343-01074-05 800Top plate attached<br />

343-02525-15 800Top plate attached<br />

343-02526-15 800Top plate attached<br />

343-02527-15 800Top plate attached<br />

1) In the above table, the * mark indicates the extension length required to mount the thermostatic chamber or furnace.<br />

2) The allowable tensile force is limited at the post extension part. The compression force will not be limited.<br />

200/250 343-01071-06<br />

300 343-01072-08<br />

300 343-01072-08<br />

700 343-01073-08<br />

1700 343-01074-08<br />

200 343-02525-18<br />

500 343-02526-18<br />

1300 343-02527-18<br />

Optional Oil Cooling Unit<br />

To perform hold control or an equivalent test continuously<br />

for 30 minutes or longer,the optional oil cooling unit may be<br />

required.<br />

<strong>Series</strong> name Capacity<br />

Part No.<br />

<strong>UH</strong>-I<br />

<strong>UH</strong>-FI<br />

200 · 300<br />

500<br />

600<br />

1000<br />

2000<br />

343-01585<br />

343-01585<br />

343-01585<br />

343-01585<br />

343-01585-01<br />

Measurement Control Unit Extension <strong>Series</strong><br />

To extend the automatic load control functions, the following control<br />

modes are available.<br />

Concrete test control function<br />

The stress speed is<br />

controlled according to<br />

the JIS A1108 concrete<br />

compression strength test<br />

method.<br />

Force<br />

LIMIT<br />

stress<br />

value<br />

1% of<br />

full-scale force<br />

Part No. 345-32722<br />

Break detection<br />

NOTE<br />

Conduct water supply/drain piping work to the position shown in the foundation<br />

reference drawing presented by Shimadzu Corporation.<br />

Constant-speed ram stroke control<br />

Stress<br />

speed<br />

control 1<br />

Stress<br />

speed<br />

control 2<br />

Time<br />

Ram return<br />

Display of force for specified elongation Part No. 345-32723<br />

This control mode conforms to the total elongation method for the JIS Z2241<br />

proof stress measurement.<br />

Force<br />

Specified<br />

elongation<br />

Pattern control function Part No. 345-32724<br />

This control mode is used to provide the load pattern to obtain the limit of the<br />

product strength from a single specimen.<br />

Stroke<br />

(Force)<br />

Specified elongation<br />

Elongation<br />

(%)<br />

Final force limit<br />

3rd force limit<br />

2nd force limit<br />

1st force limit<br />

0<br />

Limit change value<br />

Test end<br />

Time<br />

17


Layout/Installation<br />

The following figures show the standard layout of Shimadzu Universal<br />

Testing Machines. To change the layout depending on the conditions<br />

of the installation place or a change in system configuration, examine<br />

the layout referring to these figures.<br />

To install the universal testing machine, concrete foundation work is<br />

required. When purchasing this product, design and construct the<br />

foundation suitable for the conditions of the installation place (withstand<br />

strength of the ground, occupied space, etc.), referring to the foundation<br />

reference drawing presented by Shimadzu Corporation.<br />

Occupied space recommended for the standard layout<br />

* For the dimensions of the testing machine loading unit and<br />

measurement control unit of each type, see p. 14 and 15.<br />

Testing machine<br />

<strong>Series</strong> name Capacity<br />

Recommended occupied space<br />

(W x D x Hmm)<br />

Testing machine<br />

<strong>Series</strong> name Capacity<br />

Recommended occupied space<br />

(W x D x Hmm)<br />

<strong>UH</strong>-I<br />

200kN<br />

300kN<br />

500kN<br />

600kN<br />

2800 x 2350 x 2500<br />

2800 x 2350 x 2500<br />

3000 x 2350 x 3000<br />

3000 x 2550 x 3000<br />

<strong>UH</strong>-I<br />

2000kN<br />

3000kN<br />

4000kN<br />

4600 x 3500 x 4000<br />

5300 x 3900 x 5000<br />

5800 x 4300 x 6000<br />

1000kN<br />

3300 x 2400 x 3500<br />

Maintenance<br />

space Approx. 500<br />

Maintenance<br />

space Approx. 500<br />

Leakage oil return unit<br />

(in pit)<br />

Maintenance<br />

space Approx. 500<br />

Equipment width<br />

W<br />

Maintenance<br />

space Approx. 500<br />

Equipment<br />

depth<br />

Working space<br />

Approx. 1000<br />

D<br />

Maintenance<br />

space Approx. 500<br />

Pit cover<br />

(prepared by user)<br />

Maintenance<br />

space Approx. 500<br />

Equipment width<br />

Equipment<br />

depth<br />

D<br />

W<br />

Loading unit<br />

H<br />

Equipment height<br />

H<br />

Working space<br />

Approx. 1000<br />

Loading unit<br />

Equipment height<br />

Floor surface<br />

Floor surface<br />

Unit:mm<br />

Unit:mm<br />

18


1.Installation environment<br />

Avoid installing the <strong>UH</strong> series in the following harsh environments:<br />

In a place where a large temperature fluctuation is expected<br />

(Recommended temperature: +5°C to +40°C)<br />

In a place where high humidity is expected<br />

(Make sure no condensation occurs in the installation place.)<br />

In a dusty place<br />

In a place where the equipment is exposed to vibration (Recommended<br />

vibration amplitude: 5 μm or less)<br />

In a place contaminated by corrosive gas<br />

In a place where the equipment is directly exposed to vapor<br />

In a place where the equipment is directly exposed to sunlight<br />

2.Requirements for power supply<br />

Conduct electric wiring work to the position shown in the foundation<br />

reference drawing.<br />

Avoid using a power supply with large voltage fluctuations.<br />

(Recommended voltage fluctuation level: Within ±10%)<br />

If voltage fluctuations cannot be avoided, use a constant-voltage<br />

power supply.<br />

3.Cooling water<br />

To mount the optional oil cooling unit, conduct water supply/drain<br />

piping work to the position shown in the foundation reference<br />

drawing presented by Shimadzu Corporation.<br />

Testing machine<br />

<strong>Series</strong> name Capacity<br />

Recommended occupied space<br />

(W x D x Hmm)<br />

<strong>UH</strong>-FI 500kN<br />

3100 x 3400 x 3500<br />

Testing machine<br />

<strong>Series</strong> name Capacity<br />

1000kN<br />

2000kN<br />

<strong>UH</strong>-FI<br />

3000kN<br />

4000kN<br />

Recommended occupied space<br />

(W x D x Hmm)<br />

4500 x 4200 x 4300<br />

4600 x 4500 x 5400<br />

5000 x 4700 x 7100<br />

5500 x 5000 x 7500<br />

Hydraulic grip/crosshead elevation system<br />

Maintenance<br />

space Approx. 500<br />

Hydraulic grip/crosshead elevation system<br />

Maintenance<br />

space Approx. 500<br />

Hose stand<br />

Hose stand<br />

Leakage oil return unit<br />

(in pit)<br />

D<br />

W<br />

Pit cover<br />

(prepared by user)<br />

Equipment width<br />

W<br />

H<br />

H<br />

Equipment<br />

depth<br />

D<br />

Maintenance<br />

space Approx. 500<br />

Equipment width<br />

Maintenance<br />

space Approx. 500<br />

Working space<br />

Approx. 1000<br />

Loading unit<br />

Loading unit<br />

Equipment height<br />

Equipment height<br />

Equipment depth<br />

Maintenance<br />

space<br />

Approx. 500<br />

Maintenance<br />

space<br />

Approx. 500<br />

Working space<br />

Approx. 1000<br />

Floor surface<br />

Floor surface<br />

Unit:mm<br />

Unit:mm<br />

19


JQA-0376<br />

Founded in 1875, Shimadzu Corporation, a leader in the<br />

development of advanced technologies, has a distinguished<br />

history of innovation built on the foundation of contributing to<br />

society through science and technology. We maintain a global<br />

network of sales, service, technical support and applications<br />

centers on six continents, and have established long-term<br />

relationships with a host of highly trained distributors located<br />

in over 100 countries. For information about Shimadzu, and to<br />

contact your local office, please visit our Web site at<br />

www.shimadzu.com<br />

SHIMADZU CORPORATION. International Marketing Division<br />

3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan<br />

Phone: 81(3)3219-5641 Fax. 81(3)3219-5710<br />

URL http://www.shimadzu.com<br />

The contents of this brochure are subject to change without notice.<br />

Printed in Japan 4199-06603-20ATD