-Heaviest Piece during erection, 1000×Kg -----------------------------------<br />
-Heaviest Piece during maintenance, 1000×Kg --------------------------<br />
B-2 Generator and Ancillaries<br />
2.1 Generator<br />
-Manufacturer, Country ----------------------------------<br />
-Type ----------------------------------<br />
-KVA rating / power factor 0.8 ----------------------------------<br />
-Max. leading & lagging KVAR capability at pf ----------------------------------<br />
-Rated voltage between lines, KV ----------------------------------<br />
-Connection <strong>of</strong> armature winding ----------------------------------<br />
-Rated Current, A ----------------------------------<br />
-Rated frequency, Hz ----------------------------------<br />
-Efficiency<br />
at pf 0.8, % ----------------------------------<br />
at pf 1.0, % ----------------------------------<br />
-Stator overloading, % ----------------------------------<br />
-Critical speed, rpm ----------------------------------<br />
-Max. torque when the stator is short-circuited, Nm ----------------------------------<br />
-Generator Characteristics<br />
Instantaneous Max. short-circuit current<br />
at nominal voltage, A peak ----------------------------------<br />
sub-transient reactance, Xd” pu ----------------------------------<br />
transient reactance, Xd’ pu ----------------------------------<br />
synchronous reactance, Xd pu ----------------------------------<br />
negative sequence reactance, pu ----------------------------------<br />
zero sequence reactance, pu ----------------------------------<br />
field time Constant, Td’ 0 sec ----------------------------------<br />
Transient time Constant, Td sec ----------------------------------<br />
initial time Constant, Td” sec ----------------------------------<br />
-Moment <strong>of</strong> inertia GD 2 <strong>of</strong> rotor, Kg-m 2 ----------------------------------<br />
-percent rise on voltage when full load is<br />
rejected and operating at pf 0.8 , % ----------------------------------<br />
pf 1.0 , % ----------------------------------<br />
-Telephone influence factor<br />
Balanced ----------------------------------<br />
Residual ----------------------------------<br />