-Heaviest Piece during erection, 1000×Kg -----------------------------------<br />

-Heaviest Piece during maintenance, 1000×Kg --------------------------<br />

B-2 Generator and Ancillaries<br />

2.1 Generator<br />

-Manufacturer, Country ----------------------------------<br />

-Type ----------------------------------<br />

-KVA rating / power factor 0.8 ----------------------------------<br />

-Max. leading & lagging KVAR capability at pf ----------------------------------<br />

-Rated voltage between lines, KV ----------------------------------<br />

-Connection <strong>of</strong> armature winding ----------------------------------<br />

-Rated Current, A ----------------------------------<br />

-Rated frequency, Hz ----------------------------------<br />

-Efficiency<br />

at pf 0.8, % ----------------------------------<br />

at pf 1.0, % ----------------------------------<br />

-Stator overloading, % ----------------------------------<br />

-Critical speed, rpm ----------------------------------<br />

-Max. torque when the stator is short-circuited, Nm ----------------------------------<br />

-Generator Characteristics<br />

Instantaneous Max. short-circuit current<br />

at nominal voltage, A peak ----------------------------------<br />

sub-transient reactance, Xd” pu ----------------------------------<br />

transient reactance, Xd’ pu ----------------------------------<br />

synchronous reactance, Xd pu ----------------------------------<br />

negative sequence reactance, pu ----------------------------------<br />

zero sequence reactance, pu ----------------------------------<br />

field time Constant, Td’ 0 sec ----------------------------------<br />

Transient time Constant, Td sec ----------------------------------<br />

initial time Constant, Td” sec ----------------------------------<br />

-Moment <strong>of</strong> inertia GD 2 <strong>of</strong> rotor, Kg-m 2 ----------------------------------<br />

-percent rise on voltage when full load is<br />

rejected and operating at pf 0.8 , % ----------------------------------<br />

pf 1.0 , % ----------------------------------<br />

-Telephone influence factor<br />

Balanced ----------------------------------<br />

Residual ----------------------------------<br />

Re-Powering <strong>Ghorasal</strong> 210 MW 3 rd <strong>Unit</strong> (Vol-2B <strong>of</strong> 2) 12