- Manufacturer, Country ------------------------------------<br />
- Type ------------------------------------<br />
- Catalogue No. ------------------------------------<br />
-Capacity<br />
(AH at 5 Hr discharge) ------------------------------------<br />
-Number <strong>of</strong> cells per unit ------------------------------------<br />
-Weight per cell, kg ------------------------------------<br />
-Total battery weight, kg ------------------------------------<br />
-Overall dimension <strong>of</strong><br />
battery rack<br />
length, mm ------------------------------------<br />
Width, mm ------------------------------------<br />
Height, mm ------------------------------------<br />
13.6 Battery Chargers (125 V)<br />
- Manufacturer, Country ------------------------------------<br />
- Type ------------------------------------<br />
- Capacity, A/kW ------------------------------------<br />
- DC Voltage adjusting range ------------------------------------<br />
B-14 Lighting and Small Power Supply<br />
Manufacturer Cat. No. or Type<br />
- Panel boards, AC ------------------------------------<br />
- Panel boards, DC ------------------------------------<br />
- Lighting fixtures ------------------------------------<br />
B-15 Emergency Diesel Generating Set<br />
15.1 Engine<br />
- Manufacturer, Country ----------------------------<br />
-Model Number ----------------------------<br />
Installed capacity, KW ----------------------------<br />
-Number, type and arrangement <strong>of</strong><br />
cylinders ----------------------------<br />
Number <strong>of</strong> strokes ----------------------------<br />
Compressor pressure ratio ----------------------------<br />
Starting system ----------------------------<br />
Description <strong>of</strong> Speed governing system<br />
and fuel control system ----------------------------<br />
Fuel consumption ----------------------------<br />
-Description <strong>of</strong> cooling system ---------------------------<br />
-Auxiliary power consumption, KW ----------------------------<br />
Lubricating oil, litres ----------------------------<br />
- Coolant, litres ----------------------------<br />
Re-Powering <strong>Ghorasal</strong> 210 MW 3 rd <strong>Unit</strong> (Vol-2B <strong>of</strong> 2) 40