- Size <strong>of</strong> completely assembled switchgear -------------------------<br />

Length, mm -------------------------<br />

Width, mm -------------------------<br />

Weight, Kg -------------------------<br />

- Total weight <strong>of</strong> switchgear, Kg -------------------------<br />

B-12 415 V Switchgear and Motor Control Centre<br />

12.1 415 V Switchgear and Motor Control Centre<br />

- Manufacturer, Country -----------------------<br />

Manufacturer Type<br />

- Air circuit breaker<br />

Type designation -------------------------<br />

Nominal current, A -------------------------<br />

Rated Voltage, V -------------------------<br />

Method <strong>of</strong> closing -------------------------<br />

Power required to:<br />

Close -------------------------<br />

Open -------------------------<br />

Short circuit current rating, kA -------------------------<br />

Short circuit current, 3 sec, kA -------------------------<br />

Combination starter units -------------------------<br />

Starter contactor -------------------------<br />

Control trans<strong>for</strong>mer -------------------------<br />

Circuit breaker -------------------------<br />

Starter contactor coil -------------------------<br />

operating characteristics Size1 Size2<br />

Minimum pickup, V -------------------------<br />

Maximum dropout, V -------------------------<br />

Dimension <strong>of</strong> each switchgear PCC MCC<br />

Length, mm -------------------------<br />

Depth, mm -------------------------<br />

Height, mm -------------------------<br />

Weight, Kg -------------------------<br />

Number <strong>of</strong> vertical section -------------------------<br />

12.2 Switchboard Design<br />

- Degree <strong>of</strong> protection -------------------------<br />

-Short time rating<br />

Current, kA -------------------------<br />

Associated time, sec -------------------------<br />

- Type <strong>of</strong> insulation provided on<br />

bus bars and connections -------------------------<br />

- Type <strong>of</strong> protection provided within<br />

cubicles(shutter, insulating, cover, etc) -------------------------<br />

-Bus bars -------------------------<br />

Current rating <strong>of</strong> bus bars, A -------------------------<br />

System short time current,<br />

3 sec, kA -------------------------<br />

Short time current rating, 3 sec, KA -------------------------<br />

Bus bar material<br />

Cross sectional area <strong>of</strong> bus, mm 2 -------------------------<br />

Re-Powering <strong>Ghorasal</strong> 210 MW 3 rd <strong>Unit</strong> (Vol-2B <strong>of</strong> 2) 38