- Size <strong>of</strong> completely assembled switchgear -------------------------<br />
Length, mm -------------------------<br />
Width, mm -------------------------<br />
Weight, Kg -------------------------<br />
- Total weight <strong>of</strong> switchgear, Kg -------------------------<br />
B-12 415 V Switchgear and Motor Control Centre<br />
12.1 415 V Switchgear and Motor Control Centre<br />
- Manufacturer, Country -----------------------<br />
Manufacturer Type<br />
- Air circuit breaker<br />
Type designation -------------------------<br />
Nominal current, A -------------------------<br />
Rated Voltage, V -------------------------<br />
Method <strong>of</strong> closing -------------------------<br />
Power required to:<br />
Close -------------------------<br />
Open -------------------------<br />
Short circuit current rating, kA -------------------------<br />
Short circuit current, 3 sec, kA -------------------------<br />
Combination starter units -------------------------<br />
Starter contactor -------------------------<br />
Control trans<strong>for</strong>mer -------------------------<br />
Circuit breaker -------------------------<br />
Starter contactor coil -------------------------<br />
operating characteristics Size1 Size2<br />
Minimum pickup, V -------------------------<br />
Maximum dropout, V -------------------------<br />
Dimension <strong>of</strong> each switchgear PCC MCC<br />
Length, mm -------------------------<br />
Depth, mm -------------------------<br />
Height, mm -------------------------<br />
Weight, Kg -------------------------<br />
Number <strong>of</strong> vertical section -------------------------<br />
12.2 Switchboard Design<br />
- Degree <strong>of</strong> protection -------------------------<br />
-Short time rating<br />
Current, kA -------------------------<br />
Associated time, sec -------------------------<br />
- Type <strong>of</strong> insulation provided on<br />
bus bars and connections -------------------------<br />
- Type <strong>of</strong> protection provided within<br />
cubicles(shutter, insulating, cover, etc) -------------------------<br />
-Bus bars -------------------------<br />
Current rating <strong>of</strong> bus bars, A -------------------------<br />
System short time current,<br />
3 sec, kA -------------------------<br />
Short time current rating, 3 sec, KA -------------------------<br />
Bus bar material<br />
Cross sectional area <strong>of</strong> bus, mm 2 -------------------------<br />
Re-Powering <strong>Ghorasal</strong> 210 MW 3 rd <strong>Unit</strong> (Vol-2B <strong>of</strong> 2) 38